  1. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  2. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato, E-mail: masato03310402@yahoo.co.jp [Kobe University Hospital, Department of Radiology (Japan); Muradi, Akhmadu, E-mail: muradiakhmadu@gmail.com; Nomura, Yoshikatsu, E-mail: y_katsu1027@yahoo.co.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Uotani, Kensuke, E-mail: uotani@tenriyorozu.jp [Tenri Hospital, Department of Radiology (Japan); Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Miyamoto, Naokazu, E-mail: naoka_zu@yahoo.co.jp; Kawasaki, Ryota, E-mail: kawaryo1999@yahoo.co.jp [Hyogo Brain and Heart Center at Himeji, Department of Radiology (Japan); Taniguchi, Takanori, E-mail: tan9523929@yahoo.co.jp [Tenri Hospital, Department of Radiology (Japan); Okita, Yutaka, E-mail: yokita@med.kobe-u.ac.jp [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji, E-mail: kojirad@med.kobe-u.ac.jp [Kobe University Hospital, Department of Radiology (Japan)

    2013-08-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 {+-} 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35-1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary.

  3. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  4. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  5. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  6. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  7. Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Eric J.; Collins, Jeremy D. [Northwestern University Feinberg School of Medicine, Department of Radiology (United States); Crowley-Matoka, Megan [Northwestern University Feinberg School of Medicine, Center for Bioethics and Medical Humanities (United States); Chrisman, Howard B. [Northwestern University Feinberg School of Medicine, Department of Radiology (United States); Milad, Magdy P. [Northwestern University Feinberg School of Medicine, Department of Obstetrics and Gynecology-Reproductive Endocrinology and Infertility (United States); Vogelzang, Robert L., E-mail: vogelzang@northwestern.edu [Northwestern University Feinberg School of Medicine, Department of Radiology (United States)

    2017-06-15

    PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

  8. Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

    International Nuclear Information System (INIS)

    Keller, Eric J.; Collins, Jeremy D.; Crowley-Matoka, Megan; Chrisman, Howard B.; Milad, Magdy P.; Vogelzang, Robert L.

    2017-01-01

    PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

  9. Long term results of endovascular treatment in renal arterial stenosis from Takayasu arteritis: Angioplasty versus stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong Suk, E-mail: hongsukpark@gmail.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Do, Young Soo, E-mail: ysdo@skku.edu [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Park, Kwang Bo, E-mail: kbjh.park@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Kim, Duk-Kyung, E-mail: dukkyung.kim@samsung.com [Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, Sung Wook, E-mail: sw.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Shin, Sung Wook, E-mail: sw88.shin@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Cho, Sung Ki, E-mail: sungkismc@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Hyun, Dongho, E-mail: mesentery.hyun@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of); Choo, In Wook, E-mail: inwook.choo@samsung.com [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, 135-710 Seoul (Korea, Republic of)

    2013-11-01

    Purpose: To retrospectively evaluate and compare the long term patency and antihypertensive effect of angioplasty and stent insertion in renal artery stenosis caused by Takayasu arteritis, with CT angiography and clinical follow-up. Materials and methods: We retrospectively analyzed and compared effects on hypertension and patency of renal artery in 16 patients (age ranging from 16 to 58 years, mean: 32.1 years) with renovascular hypertension caused by Takayasu arteritis who underwent endovascular treatment including angioplasty (n = 13) and stent placement (n = 9) for 22 stenotic renal arteries. Results: Technical success was 95% (21/22) without major complications. In the last follow-up CT angiogram (mean 85 ± 41 months), restenosis was 8% (1/12) in angioplasty and 66% (6/9) in stent. Patency rates of angioplasty were 100%, 91.7%, 91.7% and primary unassisted and primary assisted patency rates of stent placement were 55.6%, 33.3%, 33.3% and 88.9%, 66.7%, 55.6% at 1-, 3- and 5-years, respectively. In clinical follow-up (mean 120 ± 37.8 months, range 48–183 months), beneficial effects on hypertension were obtained in 87% of patients (13/15) and there was no significant difference between the patients who were treated by only angioplasty and the patients who received stent placement in at least one renal artery, regardless of whether or not angioplasty had been performed in the other renal artery. Conclusion: Compared with stent placement, angioplasty demonstrated better long term patency and similar clinical benefit on renovascular hypertension in renal artery stenosis of Takayasu arteritis. We suggest that stent placement should be reserved for obvious angioplasty failure.

  10. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  11. Subintimal stent placement in patients with long segment occlusion of the iliac artery

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ho Jung; Kim, Young Hwan; Kim, Si Hyung; Ko, Sung Min; Choi, Jin Soo; Lee, Hyun Jin; Kim, Hyung Tae; Jo, Won Hyun [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of)

    2008-01-15

    We evaluated the technical feasibility and clinical efficacy of subintimal stent placement for long segment occlusion of the iliac artery. From March 2003 to February 2007, subintimal stent placement for long segment occlusion of the iliac artery of 24 limbs in 22 patients was analyzed retrospectively. Endovascular access was performed via the ipsilateral femoral artery in 7 cases, via the contralateral femoral artery in 6 cases, via both femoral arteries in 10 cases and via the brachial artery in one case. The SAFARI (subintimal arterial flossing with antegrade-retrograde intervention) technique using a microcatheter was performed to recannalize iliac artery occlusion in three cases. Medical records were reviewed for the collection of follow-up data. The stent patency rate was analyzed by use of the Kaplan-Meier method. Subintimal stent placement was technically successful in 23 of 24 procedures (95.8%). The mean ankle-brachial index (ABI) increased form 0.26 to 0.82. The Fontaine classification was improved after stent placement in all patients. Major complications occurred in four procedures: three distal embolizations and one arterial rupture. All of the complications were successfully treated by endovascular intervention. The primary stent patency rates at 6-months, 1-, 2-and 3-years were 95%, 88%, 88% and 88%, respectively. Subintimal stent placement is a safe and effective treatment for long segment occlusion of the iliac artery.

  12. Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils in a canine model

    International Nuclear Information System (INIS)

    Liu Jianmin; Zhang Xin; Zhou Xiaoping; Hong Bo; Xu Yi; Huang Qinghai; Zhang Long; She Jiagui; Zhao Rui

    2004-01-01

    Objective: To assess hemodynamics and histology of the aneurysms by treating experimental wide-necked aneurysms endovascularly with a combination of stents and electrolytic detachable coils. Methods: An experimental model was surgically constructed in the necks of six canines for simulating intracranial wide-necked aneurysms. Balloon-expandable metal stents were positioned across the aneurysms in bilateral carotid arteries of six canines with additional intraaneurysmal placement of detachable microcoils in only unilateral carotid artery of each canine. Sonography and angiography were performed in different stages and histologic examinations were achieved finally. Results: Stent placement was successful in all six canines. Aneurysms treated with only stents placement showed no significant thrombus formation with slow growing of neointima over the neck of the aneurysm. Thrombosis occurred in the aneurysms treated with stents and coils in a short time and neointima covered the neck of the aneurysms completely. Conclusions: Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils may prevent re-rupture of the aneurysms and promote neointima formation over the neck of the aneurysms. (authors)

  13. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  14. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  15. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  16. Statistical parametric mapping and statistical probabilistic anatomical mapping analyses of basal/acetazolamide Tc-99m ECD brain SPECT for efficacy assessment of endovascular stent placement for middle cerebral artery stenosis

    International Nuclear Information System (INIS)

    Lee, Tae-Hong; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Kim, Dong-Soo; Park, Kyung-Pil

    2007-01-01

    Statistical parametric mapping (SPM) and statistical probabilistic anatomical mapping (SPAM) were applied to basal/acetazolamide Tc-99m ECD brain perfusion SPECT images in patients with middle cerebral artery (MCA) stenosis to assess the efficacy of endovascular stenting of the MCA. Enrolled in the study were 11 patients (8 men and 3 women, mean age 54.2 ± 6.2 years) who had undergone endovascular stent placement for MCA stenosis. Using SPM and SPAM analyses, we compared the number of significant voxels and cerebral counts in basal and acetazolamide SPECT images before and after stenting, and assessed the perfusion changes and cerebral vascular reserve index (CVRI). The numbers of hypoperfusion voxels in SPECT images were decreased from 10,083 ± 8,326 to 4,531 ± 5,091 in basal images (P 0.0317) and from 13,398 ± 14,222 to 7,699 ± 10,199 in acetazolamide images (P = 0.0142) after MCA stenting. On SPAM analysis, the increases in cerebral counts were significant in acetazolamide images (90.9 ± 2.2 to 93.5 ± 2.3, P = 0.0098) but not in basal images (91 ± 2.7 to 92 ± 2.6, P = 0.1602). The CVRI also showed a statistically significant increase from before stenting (median 0.32; 95% CI -2.19-2.37) to after stenting (median 1.59; 95% CI -0.85-4.16; P = 0.0068). This study revealed the usefulness of voxel-based analysis of basal/acetazolamide brain perfusion SPECT after MCA stent placement. This study showed that SPM and SPAM analyses of basal/acetazolamide Tc-99m brain SPECT could be used to evaluate the short-term hemodynamic efficacy of successful MCA stent placement. (orig.)

  17. The management of unimplantable stent during endovascular procedure:report of three cases

    International Nuclear Information System (INIS)

    Xiong Jiang; Wang Lijun; Guo Wei; Liu Xiaoping; Yin Tai; Jia Xin; Ma Xiaohui; Liu Meng; Zhang Hongpeng; Zhang Minhong

    2010-01-01

    Objective: To summarize the experience of dealing with the difficulty of the stent implantation encountered in the endovascular procedure. Methods: The causes of unimplantable stent encountered in the endovascular procedure included the delivery system entraping due to the stenosis and shrinking of peripheral self-expandable stent, the balloon expandable stent implantation and retrievement failure due to the rupture-balloon or stent edge opening, and the delivery system entraping due to aortic stent graft for aorta kinking. The balloon dilation for the stenosis and shrinking stent, the large caliber introducer sheath for removal of the rupture-balloon and edge opening, the expandable stent and balloon-assisted delivery system retrieve were used to solve the above three dilemma of unimplantable stent occurred in the endovascular procedure. Results: These three dilemma of stent unimplantable problem in the endovascular therapy were solved by endovascular method while little additional incision injury was added to the patients. Conclusion: For solving stent unimplantable problem the endovascular technique is the method of first choice, nevertherless, it is very important for the operator to be highly skilled in manipulating endovascular procedure. (authors)

  18. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  19. Stent Fracture and Reocclusion After Placement of a Single Self-Expanding Stent in the Common Iliac Artery and Endovascular Treatment

    International Nuclear Information System (INIS)

    Higashiura, Wataru; Sakaguchi, Shoji; Morimoto, Kengo; Kichikawa, Kimihiko

    2008-01-01

    We present a case of fracture of a single self-expanding stent placed in the common iliac artery (CIA). An 80-year-old woman underwent placement of a self-expanding stent for CIA occlusion. Stent fracture and reocclusion were detected after 18 months. Successful revascularization was achieved using a stent-in-stent maneuver. The possibility of stent fracture with reocclusion should be considered following treatment with a single self-expanding stent for CIA occlusion.

  20. Primary Self-Expandable Nitinol Stent Placement in Focal Lesions of Infrarenal Abdominal Aorta: Long Term Results

    International Nuclear Information System (INIS)

    Lastovickova, Jarmila; Peregrin, Jan H.

    2008-01-01

    Purpose. To evaluate the technical and clinical success, safety and long term results of percutaneous transluminal angioplasty/self-expandable nitinol stent placement of infrarenal abdominal aorta focal lesions. Materials and Methods. Eighteen patients underwent PTA of focal atherosclerotic occlusive disease of distal abdominal aorta. Two symptomatic occlusions and 16 stenoses in 10 male and 8 female patients (mean age 68.2 years) were treated with primary self-expandable nitinol stent placement. Results. Primary self-expandable nitinol stent placement was technically successful in all 18 procedures; clinical success was achieved in 100% of patients. No complications associated with the procedure occurred. During the 49.4 months of mean follow up (range 3-96, 4 months) all treated aortic segments remained patent. Conclusions. Endovascular treatment (primary self-expandable nitinol stent placement) of focal atherosclerotic lesions of distal abdominal aorta is a safe method with excellent primary technical and clinical success rates and favourable Long term results

  1. Budd-Chiari syndrome due to prothrombotic disorder: mid-term patency and efficacy of endovascular stents

    Energy Technology Data Exchange (ETDEWEB)

    Pelage, Jean-Pierre; Denys, Alban; Sibert, Annie; Menu, Yves [Department of Radiology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Valla, Dominique [Department of Hepatology, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France); Sauvanet, Alain; Belghiti, Jacques [Department of Surgery, Hopital Beaujon, AP-HP, 100 Boulevard du General Leclerc, 92110 Clichy (France)

    2003-02-01

    Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients. (orig.)

  2. Endovascular stenting for treatment of complex intracranial aneurysms: preliminary outcome

    International Nuclear Information System (INIS)

    Huang Qinghai; Liu Jianmin; Xu Yi; Hong Bo; Zhao Wenyuan; Zhou Xiaoping

    2004-01-01

    Objective: To summarize the technique and efficiency of combined endovascular stenting and Guglielmi detachable coils (GDC) packing for the treatment of intracranial wide-necked bifurcation aneurysms and recanalized aneurysms. Methods: The coronary stents were implanted across the necks of 5 intracranial wide-necked aneurysms (two at bifurcation of ICA, one at basilar artery and two recanalized PcoA aneurysms). The porous stents covered the ostia of vital side branches and perforating vessels in three cases. Microcatheters were introduced into the aneurysmal sac through the stent mesh and then followed by GDCs embolizing the aneurysms. Results: The stents were deployed in parent artery in all cases. Total occlusion was obtained in 4 cases, while more than 90% in one case with patency of the parent arteries and vital perforating arteries. Follow-up angiography performed in all patients 3-6 months later revealed no intrastent stenosis. All the patients recovered well except III nerve palsy in one patient which diminished 3 months later. Conclusion: Endovaseular therapy combined stent implantation and microcoil placement maybe a valid alteration for the treatment of wide-necked bifurcation aneurysms and recanalized aneurysms, which shows promise clinical application in the future. The ostia of vital side branches covered with stents showed no effect on hemodynamics. (authors)

  3. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  4. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  5. Mechanical thrombectomy using Rotarex system and stent-in-stent placement for treatment of distal femoral artery occlusion secondary to stent fracture – a case report and literature review

    International Nuclear Information System (INIS)

    Dys, Krzysztof; Drelichowska-Durawa, Justyna; Dołega-Kozierowski, Bartosz; Lis, Michał; Sokratous, Kyriakos; Iwanowski, Wojciech; Drelichowski, Stanisław; Witkiewicz, Wojciech

    2013-01-01

    Treatment of peripheral arterial diseases may be distinguished into conservative and interventional management; the latter is divided into surgical and endovascular procedures. Management of peripheral artery stenosis and occlusion with vascular stents is associated with the risk of late complications such as restenosis, stent fracture or dislocation. A 62-year-old woman with generalized atherosclerosis, particularly extensive in lower limb arteries, was admitted to the Department of Angiology 11 months after having an endovascular procedure performed due to critical ischemia of left lower limb. Because of stent occlusion, a decision to perform angiographic examination of lower limb arteries was made. Examination revealed occlusion of the superficial femoral artery along its entire length, including previously implanted stents. Distal stent was fractured with slight dislocation of the proximal segment. A decision was made to perform mechanical thrombectomy using a Rotarex system followed by a stent-in-stent placement procedure. Follow-up angiography and ultrasound scan performed 24 hours after the procedure revealed a patent vessel with satisfactory blood flow. Nowadays, imaging diagnostics of peripheral artery stenosis involves non-invasive examinations such as ultrasound, minimally invasive examinations such as angio-MRI and MDCT, or invasive examinations such as DSA and IVUS. DSA examinations are used to confirm significant stenosis or occlusion of a vessel, particularly when qualifying a patient for endovascular treatment. Due to their anatomic location, the superficial femoral artery and the popliteal artery are subject to various forces e.g. those exerted by the working muscles. Mechanical thrombectomy and atherectomy are efficient methods of arterial recanalization used in the treatment of acute, subacute or even chronic occlusions or stenosis of peripheral vessels. Frequency of angioplasty and vascular stent implantation procedures is increased in patients

  6. An experimental study on expandable endovascular metallic stents in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Kim, Hak Nam [Chonbuk National University College of Medicine, Chonju (Korea, Republic of)

    1990-12-15

    We constructed an expandable endovascular metallic stent in the same way as Giamturco did. Experiments were made to test the ability of these stents to be used in the vessels. A total of 20 stents were passed through a 8.5 French teflon sheath into the normal abdominal aorta. IVC, and iliac artery of four adult dogs for 4 weeks to 12 weeks; 8 stents (10 mm in diameter fully expanded and 20 mm in length) in the abnormal aorta, 7 stents (12 mm/20 mm) in the IVC, and 5 stents (8 mm/20 mm) in the iliac artery. All but two stents showed no migration, and one complete occlusion occurred in right iliac artery of a dog. Histologically, stents wires were covered by neo-intimal proliferation. The side branches of the main vessels remained patent, even stent wires across their orifices. These metallic stents may be used as an endovascular graft material in the nonsurgical treatment of several forms of vascular disease.

  7. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  8. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  9. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  10. Endovascular treatment of acutely ruptured, wide-necked anterior communicating artery aneurysms using the Enterprise stent.

    Science.gov (United States)

    Huang, Qing-Hai; Wu, Yong-Fa; Shen, Jie; Hong, Bo; Yang, Peng-Fei; Xu, Yi; Zhao, Wen-Yuan; Liu, Jian-Min

    2013-02-01

    The treatment of anterior communicating artery (AcomA) wide-necked aneurysms with the Enterprise stent (Codman, Miami Lakes, FL, USA) has not been commonly described, due to the complexity of the vascular anatomy and the small vessels of the AcomA complex. To evaluate the feasibility, effectiveness and safety of Enterprise stent placement in AcomA aneurysms, we performed this retrospective study. Between November 2008 and December 2010, 27 wide-necked AcomA ruptured aneurysms were treated within 72 hours of ictus with the Enterprise stent. Data collected and analyzed were: demographic data, morphologic features of the aneurysm, treatment results and follow-up results. Twenty-nine Enterprise stents were successfully deployed in all 27 aneurysms, including Y-configuration stent deployment in two patients. The initial embolization degrees were Raymond class I in 20 patients, class II in five and class III in the other two. The angiographic follow-up of 21 patients (mean, 8.4 months) showed that all aneurysms remained stable or improved; there was no in-stent stenosis, recurrence or retreatment. The clinical follow-up of 26 patients (mean, 12.6 months) showed that 23 patients displayed no symptoms and no or mild disability; three patients remained with severe or moderately severe disability. The Enterprise stent is feasible and safe for endovascular embolization of wide-necked AcomA ruptured aneurysms. Further follow up is needed to assess the long-term efficacy of Enterprise stent placement in AcomA. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  12. Treatment of Endovascular Coil and Stent Migration Using the Merci Retriever: Report of Three Cases

    Directory of Open Access Journals (Sweden)

    David K. Kung

    2012-01-01

    Full Text Available Background. Coil and stent migration is a potentially catastrophic complication in endovascular neurosurgery, which may lead to cerebral thromboembolism. Techniques for removing migrated coil and stent are not well established. Methods and Results. We present three cases in which coil or stent migration occurred during endovascular embolization of a cerebral aneurysm. The Merci Retrievers were used successfully in all cases to remove the displaced foreign bodies. Technical details are described. Conclusion. The Merci Retriever device can be utilized successfully for removal of migrated coils and stents in endovascular neurosurgery.

  13. Endovascular stents: a review of their use in peripheral arterial disease.

    Science.gov (United States)

    Kudagi, Vinod S; White, Christopher J

    2013-06-01

    Technological advances in the past decade have shifted revascularization strategies from traditional open surgical approaches toward lower-morbidity percutaneous endovascular treatments for patients with lower extremity peripheral arterial disease (PAD). The continuing advances in stent design, more than any other advances, have fueled the growth of catheter-based procedures by improving the safety, durability, and predictability of percutaneous revascularization. Although the 2007 TransAtlantic Inter-Society Consensus (TASC) guidelines recommend endovascular therapy for type A and B aortoiliac and femoropopliteal lesions, recent developments in stent technology and increased experience of interventionists have suggested that a strategy of endovascular therapy first is appropriate in experienced hands for TASC type D lesions. The role of endovascular interventions is also expanding in the treatment of limb-threatening ischemia.

  14. Bronchoscopic guidance of endovascular stenting limits airway compression.

    Science.gov (United States)

    Ebrahim, Mohammad; Hagood, James; Moore, John; El-Said, Howaida

    2015-04-01

    Bronchial compression as a result of pulmonary artery and aortic arch stenting may cause significant respiratory distress. We set out to limit airway narrowing by endovascular stenting, by using simultaneous flexible bronchoscopy and graduated balloon stent dilatation, or balloon angioplasty to determine maximum safe stent diameter. Between August 2010 and August 2013, patients with suspected airway compression by adjacent vascular structures, underwent CT or a 3D rotational angiogram to evaluate the relationship between the airway and the blood vessels. If these studies showed close proximity of the stenosed vessel and the airway, simultaneous bronchoscopy and graduated stent re-dilation or graduated balloon angioplasty were performed. Five simultaneous bronchoscopy and interventional catheterization procedures were performed in four patients. Median age/weight was 33 (range 9-49) months and 14 (range 7.6-24) kg, respectively. Three had hypoplastic left heart syndrome, and one had coarctation of the aorta (CoA). All had confirmed or suspected left main stem bronchial compression. In three procedures, serial balloon dilatation of a previously placed stent in the CoA was performed and bronchoscopy was used to determine the safest largest diameter. In the other two procedures, balloon testing with simultaneous bronchoscopy was performed to determine the stent size that would limit compression of the adjacent airway. In all cases, simultaneous bronchoscopy allowed selection of an ideal caliber of the stent that optimized vessel diameter while minimizing compression of the adjacent airway. In cases at risk for airway compromise, flexible bronchoscopy is a useful tool to guide endovascular stenting. Maximum safe stent diameter can be determined without risking catastrophic airway compression. © 2014 Wiley Periodicals, Inc.

  15. Endovascular treatment with a stent-graft for internal carotid artery laceration during trans sphenoidal surgery: a case report

    International Nuclear Information System (INIS)

    Choe, Eun Hwa; Ko, Ji Ho; Lee, Tae Hong; Rho, Myung Ho

    2008-01-01

    An internal carotid artery (ICA) tear during or after trans-sphenoidal surgery (TSS) is rare but may cause potentially lethal complications. A 23-year-old female patient visited our hospital for treatment of a Rathke's cleft cyst. The patient had massive hemorrhage during surgery and angiography performed after surgery showed laceration of the cavernous ICA. We successfully controlled the hemorrhage with emergency placement of an endovascular stent-graft

  16. Short vs prolonged dual antiplatelet treatment upon endovascular stenting of peripheral arteries

    Directory of Open Access Journals (Sweden)

    Kronlage M

    2017-10-01

    Full Text Available Mariya Kronlage,1 Maximilian Wassmann,1 Britta Vogel,1 Oliver J Müller,1 Erwin Blessing,2 Hugo Katus,1,3 Christian Erbel1 1Department of Cardiology, Angiology and Pneumology, University Hospital Heidelberg, Heidelberg, 2SRH Klinikum Karlsbad Langensteinbach, Karlsbad, 3DZHK German Center for Cardiovascular Research, Partner Site Heidelberg/Mannheim, Mannheim, Germany Introduction: Peripheral artery disease (PAD is a highly prevalent disorder with a substantial economical burden. Dual antiplatelet treatment (DAPT upon endovascular stenting to prevent acute thrombotic reocclusions is an universally accepted practice for postinterventional management of PAD patients. However, the optimal period of time for DAPT upon endovascular stenting is not known.Methods: In the current nonrandomized, retrospective monocentric study, we evaluated the duration of DAPT upon endovascular stenting. A total of 261 endovascular SFA and iliac stenting procedures were performed on 214 patients and these patients were subdivided into a short (4–6 weeks or a prolonged (8–12 weeks DAPT regime group. More than 65% of the patients included were male, approximately 35% were diabetic, and 61% had a history of smoking. Of all the patients, 90% exhibited a Rutherford stage 2–3, and approximately half of the patients had a moderate-to-severe calcified target lesion with a length of >13 cm. Major safety end points were defined as any bleeding, compartment syndrome, and ischemic events. In addition to this, patency, all-cause mortality, as well as amputation were followed up over a period of 12 months upon intervention.Results: Twelve months after endovascular stenting, primary patency in our cohort was comparable between the groups (83.94% short vs 79.8% long DAPT, P>0.05. Major bleeding occurred in 18 cases without any difference between the groups (P>0.05. In addition, during the 12-month follow-up, 6 (3.4% patients in the short and 3 (3.5% in the prolonged DAPT regime

  17. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  18. Mechanical Behavior of Fully Expanded Commercially Available Endovascular Coronary Stents

    OpenAIRE

    Tambaca, Josip; Canic, Suncica; Kosor, Mate; Fish, R. David; Paniagua, David

    2011-01-01

    The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.

  19. Radiologic placement of metallic esophageal stents: preliminary experience

    International Nuclear Information System (INIS)

    Good, S.; Asch, M.R.; Jaffer, N.; Casson, A.G.

    1997-01-01

    To assess the usefulness of covered, self expanding metallic stents for alleviating stricture associated with malignant esophageal lesions. Patients and methods: Self-expanding metallic stents were placed in 10 patients with dysphagia related to stricture caused by malignant esophageal lesions. The stents were placed fluoroscopically with local anesthesia, and patency of the esophageal lumen was assessed by barium study after the procedure. The patients were then followed clinically. Results: In all 10 cases patency of the lumen was renewed after stent placement. After the procedure 9 of the patients could tolerate a normal or near-normal diet; in the other patient esophageal perforation occurred, and clinical deterioration prevented oral intake of food. In one patient, 2 stents were needed because of the length of the stricture. Two patients experienced reflux after placement of the stent across the gastro-esophageal junction. Another patient had asymptomatic aspiration after stent placement in the proximal esophagus. In 2 patients, symptoms associated with tracheoesophageal fistula were relieved after placement of the stents. Six of the 10 patients died; mean survival after the procedure was 12 (range 1 to 56) weeks. The other 4 patients were alive at the time of writing, having survived for a mean of 7.5 (range 2 to 13) weeks; all of these patients tolerated a near-normal diet. Conclusions: The placement of covered, self-expanding metallic stents is a quick, effective method of palliating dysphagia related to stricture caused by malignant esophageal lesions. (author)

  20. Reintervention for stent occlusion after bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction.

    Science.gov (United States)

    Inoue, Tadahisa; Naitoh, Itaru; Okumura, Fumihiro; Ozeki, Takanori; Anbe, Kaiki; Iwasaki, Hiroyasu; Nishie, Hirotada; Mizushima, Takashi; Sano, Hitoshi; Nakazawa, Takahiro; Yoneda, Masashi; Joh, Takashi

    2016-11-01

    Endoscopic reintervention for stent occlusions following bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstruction (MHBO) is challenging, and time to recurrent biliary obstruction (RBO) of the revisionary stent remains unclear. We aimed to clarify a suitable reintervention method for stent occlusions following bilateral SEMS placement for MHBO. Between 2002 and 2014, 52 consecutive patients with MHBO who underwent endoscopic reintervention for stent occlusion after bilateral SEMS placement were enrolled at two university hospitals and one tertiary care referral center. We retrospectively evaluated the technical and functional success rates of the reinterventions, and the time to RBO of the revisionary stents. Technical and functional success rates of the reinterventions were 92% (48/52) and 90% (43/48), respectively. Univariate analysis did not determine any significant predictive factors for technical and functional failures. Median time to RBO of the revisionary stents was 68 days. Median time to RBO was significantly longer for revisionary SEMS placement than for plastic stent placement (131 days vs 47 days, respectively; log-rank test, P = 0.005). Revisionary SEMS placement was the only independent factor that was significantly associated with a longer time to RBO of the revisionary stent in the multivariate Cox proportional hazards analysis (hazard ratio 0.37; 95% confidence interval 0.14-0.95; P = 0.039). Revisionary SEMS placement is a suitable endoscopic reintervention method for stent occlusion following bilateral SEMS placement from the perspective of time to RBO of the revisionary stent. © 2016 Japan Gastroenterological Endoscopy Society.

  1. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  2. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Leto, John; George, Christopher; Van Epps, Kelly; Woeste, Troy; Berlet, Mathew

    2008-01-01

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus

  3. Endovascular treatment of intrahepatic inferior vena cava obstruction from malignant hepatocellular tumor thrombus utilizing Luminexx self-expanding nitinol stents

    Energy Technology Data Exchange (ETDEWEB)

    Stambo, Glenn W. [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)], E-mail: xraydoc2@yahoo.com; Leto, John [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 3001 W. Dr. Martin Luther King Jr. Blvd., Tampa, FL 33607 (United States); George, Christopher [Department of Hematology and Oncology, St. Joseph' s Hospital and Medical Center, 4301 W. Habana Avenue, Suite 1, Tampa, FL 33607 (United States); Van Epps, Kelly; Woeste, Troy; Berlet, Mathew [Division of Vascular and Interventional Radiology, Department of Radiology, St. Joseph' s Hospital and Medical Center, 4516 North Armenia Avenue, Tampa, FL 33603 (United States)

    2008-05-15

    Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically reliable, and has essentially no morbidity or mortality. This procedure can be performed in the interventional radiology suite with excellent results resolving the IVC syndrome soon after placement of the stents. We believe endovascular stenting as an excellent palliative therapy for patients with IVC syndrome and should be the treatment of choice for caval obstructions due to intraluminal tumor thrombus.

  4. Endovascular stent-graft placement for the treatment of acute onset and chronic aortic dissections of the descending aorta (Short-term follow-up)

    International Nuclear Information System (INIS)

    Petrov, I; Jorgova, J.; Trendafilova, D.

    2004-01-01

    The leading cause of death for patients with surgically untreated thoracic aortic aneurysms is the rupture of the aneurysm. Almost one half of these patients are left to medical treatment assuming the risk of late rupture and aneurysm sac enlargement - the late surgical treatment of these patients is too risky and with poor results. On the other hand the emergent surgical treatment of these cases is related with relatively high mortality rate. Recently, thoracic aortic stent-grafting has emerged as a less traumatic alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. The first case of stent implantation in a dissected descending aorta was performed in Bulgaria at 09.04.2003. Since then we implanted in 8 patients thoracic stent grafts, The mean age of the patients was 67.5 years. The primary success was 100%. One died on the second postoperative day by abdominal aorta rupture. No other complications were registered. The mean follow-up of 5 months proved to be uneventful and the control CT revealed efficacious sealing of the entry and false lumen thrombosis in all except one cases. We report our initial clinical experience of endovascular stent-graft repair for dissection of the descending aorta that is encouraging. These preliminary data suggest that endovascular stent-grafting is a viable treatment for acute onset and chronic aortic dissection type B

  5. Percutaneous placement of ureteral stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Park, Jae Hyung; Han, Joon Koo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Antegrade placement of ureteral stents has successfully achieved in 41 of 46 ureters. When it was difficult to advance ureteral stents through the lesion, it was facilitated by retrograde guide-wire snare technique through urethra. Complications associated with the procedure were non-function of ureteral stent by occlusion, upward migration,and spontaneous fracture of ureteral stent. These complications were managed by percutaneous nephrostomy and removal of ureteral stents by guide-wire snare technique and insertion of a new ureteral stent. While blood cell in urine was markedly increased in about 50% of patients following the procedure.

  6. A Phase II study of external-beam radiotherapy and endovascular brachytherapy with PTA and stenting for femoropopliteal artery restenosis

    International Nuclear Information System (INIS)

    Narayan, Kailash; Denton, Michael; Das, Ram; Bernshaw, David; Rolfo, Aldo; Dyk, Sylvia van; Mirakian, Alex

    2006-01-01

    Purpose: To assess the safety and seek evidence of efficacy of combined external-beam radiotherapy (EBRT) and endovascular brachytherapy in the treatment of stenotic vascular lesions. Methods and Materials: Seventeen patients with high risk for restenosis of femoropopliteal arteries were enrolled in this study from February 2000 to August 2002. The external beam radiotherapy regimen consisted of 10 Gy in 5 fractions of 2 Gy, starting on Day 0. This was followed on Day 6 by angiography, stent placement, and intraluminal brachytherapy to a dose of 10 Gy at 1.2 mm from stent surface. The EBRT was continued from the same day to another 10 Gy in 2 Gy daily fractions for 5 days. Results: The follow up ranged from 33 months to 60 months. At the time of analysis 15 of 17 patients were alive with patent stents. Of these, 10 were symptom-free. Two patients died of unrelated causes. Conclusions: The combination of EBRT and endovascular brachytherapy provided adequate dose distribution without any geographical miss or 'candy wrapper' restenosis. No incidence of aneurysmal dilation of radiated vascular segment was observed. The treatment was feasible, well tolerated, and achieved 88% stenosis free survival

  7. Treatment of portal hypertension caused by benign main portal vein stenosis with endovascular stent

    International Nuclear Information System (INIS)

    Huang Mingsheng; Shan Hong; Jiang Zaibo; Guan Shouhai; Zhu Kangshun; Li Zhengran; Zhou Yubin; He Bingjun

    2004-01-01

    Objective: To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Methods: Portal vein stents were implanted in 6 patients with benign main portal vein stenosis (inflammatory stenosis in 3 cases, postprocedure of liver transplantation in another 3 cases). The change of portal vein pressure, the patency of portal vein, relative clinical symptoms, complications, and survival were evaluated. Results: Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in all 6 patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3 ± 4.7) cm H 2 O (1 cm H 2 O=0.098 kPa) to (18.0 ± 1.9) cm H 2 O (P<0.001). The portal blood flow was restored, and the symptoms caused by portal hypertension were eliminated. There was no severe procedure-related complication. Follow-up time was from 5 to 36 months. The portal vein remained patent during the follow-up. All patients survived except one patient who died of other complications of liver transplantation. Conclusion: Percutaneous portal vein stent placement for the treatment of the benign main portal vein stenosis is safe and effective. (authors)

  8. Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang

    2010-01-01

    Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)

  9. Acute Iliac Artery Rupture: Endovascular Treatment

    International Nuclear Information System (INIS)

    Chatziioannou, A.; Mourikis, D.; Katsimilis, J.; Skiadas, V.; Koutoulidis, V.; Katsenis, K.; Vlahos, L.

    2007-01-01

    The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft is a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results

  10. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    International Nuclear Information System (INIS)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo

    2014-01-01

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  11. Covered stent placement for the treatment of malignant superior vena cava syndrome: Is unilateral covered stenting and effective?

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Young Hoon; Gwon, Dong Il; Ko, Gi Young; Ko, Heung Kyu; Kim, Jin Hyoung; Shin, Ji Hoon; Yoon, Hyun Ki; Sung, Kyu Bo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2014-02-15

    To evaluate the safety and efficacy of unilateral covered stent placement in patients with malignant superior vena cava (SVC) syndrome. Between October 2008 and November 2012, expanded polytetrafluoroethylene-covered stent placement for malignant SVC syndrome was performed in 40 consecutive patients (35 men and five women; mean age, 61.4 years; range, 35-81 years). All covered stents were unilaterally placed within the SVC or across the venous confluence when needed to relieve venous obstruction and prevent tumor overgrowth, regardless of patency of contralateral brachiocephalic veins. Stent placement was technically successful in all patients. There were no major complications. Of the 37 patients symptomatic prior to stent placement, 34 (92%) experienced complete symptomatic relief 1-8 days after stent placement. Of the 29 patients who underwent covered stent placement across the venous confluence, nine patients had patent contralateral brachiocephalic veins prior to stent placement. However, no sign of SVC obstruction or contralateral upper extremity venous thrombosis was observed during the follow-up period. Kaplan-Meier analysis revealed median patient survival of 163 days. Stent occlusion occurred in four (10%) of 40 patents. Cumulative stent patency rates at 1, 3, 6, and 12 months were 95%, 92%, 86%, and 86%, respectively. Unilateral covered stent placement appears to be a safe and effective method for treating malignant SVC syndrome, despite the location of SVC occlusion.

  12. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  14. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    Science.gov (United States)

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  15. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    International Nuclear Information System (INIS)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-01-01

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P   0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  16. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis.

    Science.gov (United States)

    Ma, Ji; Han, Xinwei; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua

    2016-08-01

    To evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis. We conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal. A total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P  0.05). Temporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  17. Endovascular stenting of a chronic ruptured type B thoracic aortic dissection, a second chance: a case report.

    Science.gov (United States)

    Arshad, Ali; Khan, Sumaira L; Whitaker, Simon C; Macsweeney, Shane T

    2008-02-07

    We aim to highlight the need for awareness of late complications of endovascular thoracic aortic stenting and the need for close follow-up of patients treated by this method. We report the first case in the English literature of an endovascular repair of a previously stented, ruptured chronic Stanford type B thoracic aortic dissection re-presenting with a type III endoleak of the original repair. Endovascular thoracic stenting is now a widely accepted technique for the treatment of thoracic aortic dissection and its complications. Long term follow up is necessary to ensure that late complications are identified and treated appropriately. In this case of type III endoleak, although technically challenging, endovascular repair was feasible and effective.

  18. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis.

    Science.gov (United States)

    Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo

    2005-06-07

    To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.

  19. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  20. Long term results of kissing stents in the aortic bifurcation

    NARCIS (Netherlands)

    Hinnen, J.W.; Konickx, M.A.; Meerwaldt, Robbert; Kolkert, J.L.P.; van der Palen, Jacobus Adrianus Maria; Huisman, A.B.

    2015-01-01

    BACKGROUND: To evaluate the long-term outcome after aortoiliac kissing stent placement and to analyze variables, which potentially influence the outcome of endovascular reconstruction of the aortic bifurcation. METHODS: All patients treated with aortoiliac kissing stents at our institution between

  1. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  2. Endoscopic bilateral stent-in-stent placement for malignant hilar obstruction using a large cell type stent.

    Science.gov (United States)

    Park, Jin Myung; Lee, Sang Hyub; Chung, Kwang Hyun; Jang, Dong Kee; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Min; Paik, Woo Hyun

    2016-12-01

    Bilateral stent-in-stent (SIS) self-expandable metal stent placement is technically challenging for palliation of unresectable malignant hilar obstruction. In the SIS technique, the uniform large cell type biliary stent facilitates contralateral stent deployment through the mesh of the first metallic stent. This study aimed to assess the technical success and clinical effectiveness of this technique with a uniform large cell type biliary stent. Thirty-one patients who underwent bilateral SIS placement using a large cell type stent were reviewed retrospectively. All patients showed malignant hilar obstruction (Bismuth types II, III, IV) with different etiologies. Sixteen (51.6%) patients were male. The mean age of the patients was 67.0+/-14.0 years. Most patients were diagnosed as having hilar cholangiocarcinoma (58.1%) and gallbladder cancer (29.0%). Technical success rate was 83.9%. Success was achieved more frequently in patients without masses obstructing the biliary confluence (MOC) than those with MOC (95.2% vs 60.0%, P=0.03). Functional success rate was 77.4%. Complications occurred in 29.0% of the patients. These tended to occur more frequently in patients with MOC (50.0% vs 19.0%, P=0.11). Median time to recurrent biliary obstruction was 188 days and median survival was 175 days. The large cell type stent can be used efficiently for bilateral SIS placement in malignant hilar obstruction. However, the risk of technical failure increases in patients with MOC, and caution is needed to prevent complications for these patients.

  3. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  4. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ye Jin; Kim, Jin Hyoung, E-mail: m1fenew@daum.net; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center (Korea, Republic of)

    2012-10-15

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10-119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  5. Hepatocellular Carcinoma Complicated by Gastroduodenal Obstruction: Palliative Treatment with Metallic Stent Placement

    International Nuclear Information System (INIS)

    Lee, Ye Jin; Kim, Jin Hyoung; Song, Ho-Young; Park, Jung-Hoon; Na, Han Kyu; Kim, Pyeong Hwa; Fan, Yong

    2012-01-01

    Purpose: To evaluate the clinical effectiveness of self-expandable metallic stents in seven patients with malignant gastroduodenal obstruction caused by inoperable hepatocellular carcinoma (HCC). Methods: Seven patients with gastroduodenal obstruction caused by advanced HCC underwent metallic stent placement from 2003 to 2010. These patients had total dysphagia (n = 5) or were able to eat only liquids (n = 2) before stent placement. Patients had Eastern Cooperative Oncology Group performance scores of 2 or 3, and Child-Pugh classification B or C. Results: Stent placement was technically successful in all seven patients (100%) and clinically successful in six (86%). Five patients could eat a soft diet, and one patient tolerated regular diet after stent placement. Stent-related obstructive jaundice occurred in one patient. One patient had hematemesis 11 days after stent placement. Overall mean survival was 51 days (range, 10–119 days). Stent patency was preserved in six patients with clinical success until death. Conclusion: Placement of a covered self-expandable metallic stent may offer good palliation in patients with gastroduodenal obstruction due to advanced HCC.

  6. Endovascular treatment of nutcracker syndrome - a case report

    International Nuclear Information System (INIS)

    Rowinski, O.; Januszewicz, M.; Wojtaszek, M.; Nawrot, I.; Szmidt, J.

    2007-01-01

    The 'nutcracker' syndrome is most commonly caused by arterial compression of the left renal vein between the superior mesenteric artery and the aorta. As a consequence venous blood pressure increases within the renal pelvis, ureter and gonadal veins. This compression syndrome may be treated by endovascular stent implantation into the left renal vein. A 20 year old female patient was referred to us, suffering from pain in her left side, gross proteinuria and the suspicion of 'nutcracker' syndrome. Symptoms were present for the last 3 years. Angio MRI was performed and confirmed compression of the left renal vein between the aorta and the superior mesenteric artery. The patient was qualified for endovascular treatment. A self expandable metallic stent, diameter 16 x 40 mm was implanted into the left renal vein. Control venography confirmed good placement of the stent and a good immediate hemodynamic effect of the procedure. The patient remains symptom free in a 14 month follow up period. At present, endovascular stenting seems to be the method of choice for the treatment of the nutcracker syndrome. (author)

  7. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  8. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  9. Outcomes of Temporary Partially Covered Stent Placement for Benign Tracheobronchial Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Ji; Han, Xinwei, E-mail: hanxinwei2006@163.com; Wu, Gang; Jiao, Dechao; Ren, Kewei; Bi, Yonghua [The First Affiliated Hospital of Zhengzhou University, Department of Interventional Radiology (China)

    2016-08-15

    PurposeTo evaluate the intermediate outcomes of temporary partially covered tracheobronchial stenting in patients with benign tracheobronchial stenosis.Materials and MethodsWe conducted a retrospective study of patients with benign tracheobronchial stenosis who underwent stent placement. All stents were removed approximately 3 months after placement. Respiratory function was assessed using the visual analogue scale (VAS) and Karnofsky performance status scale (KPS) before and after stent placement. The lumen diameters of the stenotic lesions were measured using chest computed tomography (CT) and compared between before stent placement and after stent removal.ResultsA total of 51 stents were successfully placed in consecutive 51 patients with benign tracheobronchial stenosis. No serious complications occurred. The mean VAS and KPS scores significantly improved after stent removal (6.291 ± 0.495 and 25.352 ± 10.533, respectively) compared with those before stent placement (1.493 ± 0.504 and 60.140 ± 16.344, respectively; P < 0.05). The mean lumen transverse diameters of the stenotic site in trachea and main bronchus after stent removal (17.235 ± 3.457 and 8.993 ± 0.961 mm; 1 month post-removal; 16.353 ± 4.132 and 8.357 ± 1.082 mm; 6 months post-removal) were significantly larger than those before stent placement (7.876 ± 2.351 and 2.143 ± 0.770 mm, respectively; P < 0.05). However, the mean lumen diameters between 1 and 6 months after stent removal had no significant difference (P > 0.05).ConclusionTemporary partially covered stenting may be a safe and effective treatment for benign tracheobronchial stenosis.

  10. Delayed colonic perforation following stent placement for colorectal obstruction: a description of two cases with stent palliation.

    Directory of Open Access Journals (Sweden)

    Jalal Vahedian Ardakani

    2013-10-01

    Full Text Available Bowel stent insertion has a variety of complications one major of which is colonic perforation. The purpose of this article is to reveal two cases with delayed colonic perforation after stent placement to relieve bowel obstruction caused by rectal cancer. The first patient was a 55 year-old man who was a candidate for stent placement to avoid palliative surgery and relieve his bowel obstruction. Although the procedure resulted in complete relief of patient symptoms, but he returned with signs of peritonitis 10 days after the stent placement. A perforation was found at rectosigmoid junction on laparotomy. The second patient was a 60 year-old man who underwent a successful stent placement and returned 3 months later with a complaint of abdominal pain that showed up to be due to a rectal perforation on investigations. In conclusion, bowel perforation following stent placement can be a major complication, so close follow-up is necessary to detect it as soon as possible and prevent it from becoming an irreparable complication.

  11. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  12. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  13. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-02-15

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  14. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  15. Plastic Biliary Stent Migration During Multiple Stents Placement and Successful Endoscopic Removal Using Intra-Stent Balloon Inflation Technique: A Case Report and Literature Review.

    Science.gov (United States)

    Calcara, Calcedonio; Broglia, Laura; Comi, Giovanni; Balzarini, Marco

    2016-02-05

    Late migration of a plastic biliary stent after endoscopic placement is a well known complication, but there is little information regarding migration of a plastic stent during multiple stents placement. A white man was hospitalized for severe jaundice due to neoplastic hilar stenosis. Surgical eligibility appeared unclear on admission and endoscopy was carried out, but the first stent migrated proximally at the time of second stent insertion. After failed attempts with various devices, the migrated stent was removed successfully through cannulation with a dilation balloon. The migration of a plastic biliary stent during multiple stents placement is a possible complication. In this context, extraction can be very complicated. In our patient, cannulation of a stent with a dilation balloon was the only effective method.

  16. Placement of tracheobronchial silicone Y-stents: Multicenter experience and systematic review of the literature

    Directory of Open Access Journals (Sweden)

    Inderpaul Singh Sehgal

    2017-01-01

    Full Text Available Background: Airway obstruction or tracheoesophageal fistula (TEF near the tracheal carina requires placement of Y-shaped stents. Herein, we describe our multicenter experience with the placement of Dumon silicone Y-stents. We also conduct a systematic review for studies describing the deployment of airway silicone Y-stents. Methods: This was a retrospective analysis of consecutive subjects who underwent placement of silicone Y-stents. The clinical details including the underlying diagnosis, indication for the placement of silicone Y-stents, success of stent placement, and follow-up are presented. The PubMed and EMBASE databases were also reviewed for studies describing the placement of silicone Y-stents. Results: During the study, 27 silicone Y-stents were placed. The mean (standard deviation age of the study population (85.2% males was 57.7 (13.5 years. The stents were placed for airway obstruction in 77.8% and TEF in 29.6% of the patients. The most common underlying disease was carcinoma of the esophagus. The degree of airway obstruction was grade 3–4 in 18 subjects, and respiratory failure was encountered in 18 subjects. The stent was deployed successfully in all the subjects. No deaths were encountered during stent placement. Most subjects had rapid relief of symptoms following the procedure. Excessive secretions and mucostasis were the most common stent-related complications followed by the development of granulation tissue. The systematic review yielded nine studies (338 subjects with airway obstruction and/or TEF. The most common indication for silicone Y-stent placement was tracheobronchial obstruction and TEF due to malignancy. Benign disorders that necessitated stent placement included postintubation tracheal stenosis, airway malacia, and others. The stent was successfully placed in 98% with only one periprocedural death. Granulation tissue formation and mucostasis were the most common stent-related complications. Conclusion

  17. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  18. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric

    2010-01-01

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  19. [Eleven Patients with Gastric Cancer Who Received Chemotherapy after Stent Placement for Gastric Outlet Obstruction].

    Science.gov (United States)

    Endo, Shunji; Nakagawa, Tomo; Konishi, Ken; Ikenaga, Masakazu; Ohta, Katsuya; Nakashima, Shinsuke; Matsumoto, Kenichi; Nishikawa, Kazuhiro; Ohmori, Takeshi; Yamada, Terumasa

    2017-01-01

    Endoscopic placement of self-expandable metallic stents is reportedly effective for gastric outlet obstructions due to advanced gastric cancer, and is less invasive than gastrojejunostomy. For patients who have good performance status, we administer chemotherapy after stent placement, although the safety and feasibility of this chemotherapy have not yet been discussed in full. Between 2011 and 2015, 15 patients at our institution underwent endoscopic gastroduodenal stent placement for gastric outlet obstruction due to gastric cancer. Eleven of these patients were administered chemotherapy after stent placement. In our case series, we did not observe any specific adverse event caused by stent placement plus chemotherapy. Adverse events after chemotherapy included anemia of CTCAE Grade 3 in 7 patients. Stent-in-stent placement was needed in 2 patients. Neither stent migration nor perforation was observed. Therefore, chemotherapy after stent placement for gastric outlet obstruction due to gastric cancer was considered safe and feasible. Stent placement is useful not only as palliative care for patients with terminal-stage disease, but also as one of the multimodal therapeutic strategies for gastric cancer.

  20. Is the Routine Check Nephrostogram Following Percutaneous Antegrade Ureteric Stent Placement Necessary?

    International Nuclear Information System (INIS)

    Soh, Keng Chuan; Tay, Kiang Hiong; Tan, Bien Soo; MM Htoo, Austin; HG Lo, Richard; Lin, Shueh En

    2008-01-01

    Our aim was to review our experience with percutaneous antegrade ureteric stent (PAUS) placement and to determine if the routinely conducted check nephrostogram on the day following ureteric stent placement was necessary. Retrospective review of patients who had undergone PAUS placement between January 2004 and December 2005 was performed. There were 83 subjects (36 males, 47 females), with a mean age of 59.9 years (range, 22-94 years). Average follow-up duration was 7.1 months (range, 1-24 months). The most common indications for PAUS placement were ureteric obstruction due to metastatic disease (n = 56) and urinary calculi (n = 34). Technical success was 93.2% (96/103 attempts), with no major immediate procedure-related complications or mortalities. The Bard 7Fr Urosoft DJ Stent was used in more than 95% of the cases. Eighty-one of 89 (91.0%) check nephrostograms demonstrated a patent ureteric stent with resultant safety catheter removal. Three check nephrostograms revealed distal stent migration requiring repositioning by a goose-snare, while five others showed stent occlusion necessitating permanent external drainage by nephrostomy drainage catheter reinsertion. Following PAUS placement, the serum creatinine level improved or stabilized in 82% of patients. The serum creatinine outcome difference between the groups with benign and malignant indications for PAUS placement was not statistically significant (p = 0.145) but resolution of hydronephrosis was significantly better (p = 0.008) in patients with benign indications. Percutaneous antegrade ureteric stent placement is a safe and effective means of relief for ureteric obstruction. The check nephrostogram following ureteric stent placement was unnecessary in the majority of patients

  1. Clinical application of hepatic vein percutaneous transluminal angioplasty and stent after stent placement in inferior vena cava

    International Nuclear Information System (INIS)

    Xu Hao; Zu Maoheng; Gu Yuming; Li Guojun; Zhang Qingqiao; Wei Ning; Xu Wei; Liu Hongtao

    2005-01-01

    Objective: To investigate the feasibility and effect of recanalization of hepatic vein with percutaneous transluminal angioplasty (PTA) and stent after stent placement in inferior vena cava (IVC). Methods: Eleven patients with Budd-Chiari syndrome (BCS)were once performed metal stent placement in IVC at other hospital, but ascites was not subsided in 9 patients after the stent placement and occurred again in 2 patients in 3 months after the procedure. PTA and metal stent placement were used to treat the occlusion of the hepatic vein (HV) via stent in IVC. Results: Recanalization of occlusive HV was successful in all 11 patients, and symptoms disappeared or were obviously improved. The mean blood pressure in HV dropped from pre-operation (45.12 ± 1.57) cm H 2 O (1 cm H 2 O=0.098 kPa) to post-operation (17.53 ± 0.68) cm H 2 O (P<0.01). In a period of 4-30 months (mean: 13.6 months) following-up, no patient reoccurred symptoms. Conclusion: Recanalization of HV via stent in IVC is a feasible and effective method for occlusive HV, but it is difficult. (authors)

  2. Long-Term Results after Placement of Aortic Bifurcation Self-Expanding Stents: 10 Year Mortality, Stent Restenosis, and Distal Disease Progression

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Bhat, Raj; Ross, Rose; Stonebridge, Peter A.

    2007-01-01

    Purpose. To retrospectively evaluate the 10 year follow-up results in patients who had 'kissing' self-expanding stent aortic bifurcation reconstruction. Methods. Forty-three patients were treated with 'kissing' self-expanding stents for aortoiliac occlusive disease. Early follow-up with clinical and ankle brachial pressure indices (ABPI) was performed at 3, 6, 12, and 24 months and with intra-arterial digital subtraction angiography at 12-24 months; clinical and angiographic follow-up was performed for symptom recurrence up to 10 years after treatment. Retrospective record review was performed to assess mortality, clinical patency, angiographic patency, and secondary assisted patency of both stents and downstream peripheral vessels at 5 and 10 years follow-up. Results. The 2 year primary angiographic and secondary assisted stent patencies were 89% and 93%, respectively. At 10 years follow-up in 40 patients the mortality was 38% (due to myocardial infarction, stroke, chronic renal failure, malignancy, and liver failure). At 5 and 10 years follow-up the primary clinical stent patency was 82% and 68%, and the secondary assisted stent patency 93% and 86%, respectively. At 5 and 10 years, the distal vessel patency was 86% and 72%, and the secondary assisted distal vessel patency treated by surgical or endovascular techniques was 94% and 88%, respectively. At 10 years there was no limb loss. Conclusion. The long-term (10 year) results of aortic bifurcation arterial self-expanding stent placement in patients with arterial occlusive disease show a 10 year primary stent patency rate of 68% but a secondary assisted patency rate of 86%. In addition there is a high overall mortality due to other cardiovascular causes and the rate of distal disease progression and loss of patency is similar to the loss of stent patency rate

  3. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    International Nuclear Information System (INIS)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung; Lee, Yeoun Joo

    2013-01-01

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  4. Retrievable Airway Stent Placement for Stoma Stricture after Anterior Mediastinal Tracheostomy: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae Yeon; Shin, Ji Hoon; Kim, Yong Hee; Song, Ho Young; Kim, Jin Hyoung [Dept. of University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Lee, Yeoun Joo [Dept. of Pediatrics, Pusan National University Children' s Hospital, Yangsan (Korea, Republic of)

    2013-06-15

    Anterior mediastinal tracheostomy (AMT) is performed to establish an airway after resection of advanced tumors in the cervicothoracic region. We report a case of successful placement of a covered retrievable self-expandable nitinol stent for a stoma stricture that developed after AMT in a patient with adenoid cystic carcinoma of the trachea. Two stent placements and removals, at two and three months after their initial placement, were performed due to loosening of the stents. Although we did not achieve long-term results as the patient died of massive hemorrhage, the stent placement was both feasible and safe, thus suggesting that temporary stent placement may be a valuable option for treating stoma stricture occurring after AMT.

  5. Evaluation of the efficacy and safety of endovascular management for transplant renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Leonardo G.M. Valle

    Full Text Available OBJECTIVES: To evaluate the safety and efficacy of endovascular intervention with angioplasty and stent placement in patients with transplant renal artery stenosis. METHODS: All patients diagnosed with transplant renal artery stenosis and graft dysfunction or resistant systemic hypertension who underwent endovascular treatment with stenting from February 2011 to April 2016 were included in this study. The primary endpoint was clinical success, and the secondary endpoints were technical success, complication rate and stent patency. RESULTS: Twenty-four patients with transplant renal artery stenosis underwent endovascular treatment, and three of them required reinterventions, resulting in a total of 27 procedures. The clinical success rate was 100%. All graft dysfunction patients showed decreased serum creatinine levels and improved estimated glomerular filtration rates and creatinine levels. Patients with high blood pressure also showed improved control of systemic blood pressure and decreased use of antihypertensive drugs. The technical success rate of the procedure was 97%. Primary patency and assisted primary patency rates at one year were 90.5% and 100%, respectively. The mean follow-up time of patients was 794.04 days after angioplasty. CONCLUSION: Angioplasty with stent placement for the treatment of transplant renal artery stenosis is a safe and effective technique with good results in both the short and long term.

  6. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  7. Retrograde or antegrade double-pigtail stent placement for malignant ureteric obstruction?

    International Nuclear Information System (INIS)

    Uthappa, M.C.; Cowan, N.C.

    2005-01-01

    AIM: To determine the optimum approach for double-pigtail stent placement in malignant ureteric obstruction. PATIENTS AND METHODS: Retrograde stent placement was attempted in a consecutive series of patients presenting with malignant ureteric obstruction. If retrograde stent placement was unsuccessful, percutaneous nephrostomy was performed immediately followed by elective antegrade stent placement. Identical digital C-arm fluoroscopy for image-guidance and conditions for anaesthesia and analgesia were employed for both retrograde and antegrade procedures. Identical 8 Fr (20-26 cm) double-pigtail hydrophilic coated stents were used for each approach. RESULTS: Retrograde placement was attempted in 50 ureters in 30 patients {19 male, 11 female, average age 61.4 yr (range 29-90 yr)} over a 24-month period. The success rate for retrograde ureteric stent placement was 50% (n=25/50). Technical failures were due to failure to identify the ureteric orifice (n=22), failure to cross the stricture (n=1), failure to pass the stent (n=1) and failure to pass a 4 Fr catheter (n=1). Antegrade placement was attempted in 25 ureters with a success rate of 96% (n=24/25). Failure in the one case was due to inability to cross an upper third stricture secondary to pyeloureteritis cystica. CONCLUSION: It is suggested that retrograde route should be the initial approach if imaging shows no involvement of ureteric orifice (UO), when nephrostomy is technically very difficult or in cases of solitary kidney. The antegrade route is preferred if imaging shows tumour occlusion of the UO or if there is a tight stricture very close to the uretero-vesical junction (UVJ) making purchase within the ureter difficult for crossing the stricture

  8. Prospective Multicenter Study on the Challenges Inherent to Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Lee, Sang Hyub; Ryu, Ji Kon; Kim, Yong-Tae; Woo, Sang Myung; Lee, Woo Jin; Jeong, Seok; Lee, Don Haeng

    2018-06-22

    Although endoscopic bilateral stent-in-stent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic reintervention. This study aimed to evaluate the technical feasibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases with technical success. Stent occlusion occurred in 63.2% of patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Large cell-type stents for endoscopic bilateral stent-in-stent placement showed acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

  9. Endovascular stentectomy using the snare over stent-retriever (SOS technique: An experimental feasibility study.

    Directory of Open Access Journals (Sweden)

    Tareq Meyer

    Full Text Available Feasibility of endovascular stentectomy using a snare over stent-retriever (SOS technique was evaluated in a silicon flow model and an in vivo swine model. In vitro, stentectomy of different intracranial stents using the SOS technique was feasible in 22 out of 24 (92% retrieval maneuvers. In vivo, stentectomy was successful in 10 out of 10 procedures (100%. In one case self-limiting vasospasm was observed angiographically as a technique related complication in the animal model. Endovascular stentectomy using the SOS technique is feasible in an experimental setting and may be transferred to a clinical scenario.

  10. The benefit of stent placement and blood pressure and lipid-lowering for the prevention of progression of renal dysfunction caused by atherosclerotic ostial stenosis of the renal artery. The STAR-study: rationale and study design.

    NARCIS (Netherlands)

    Bax, L.; Mali, W.P.Th.; Buskens, E.; Koomans, H.A.; Beutler, J.J.; Braam, B.; Beek, F.J.A.; Rabelink, T.J.; Postma, C.T.; Huysmans, F.T.M.; Deinum, J.; Thien, Th.; Schultze Kool, L.J.; Woittiez, A.J.J.; Kouwenberg, J.J.; Meiracker, A.H. van den; Pattynama, P.M.; Ven, P.J. van der; Vroegindeweij, D.; Doorenbos, C.J.; Aarts, J.; Kroon, A.A.; Leeuw, P.W. de; Haan, M.W. de; Engelshoven, J. van; Rutten, M.J.C.M.; Montfrans, G.A. van; Reekers, J.A.; Plouin, P.F.; Batide Alanore, A. La; Azizi, M.; Raynaud, A.; Harden, P.N.; Cowling, M.

    2003-01-01

    BACKGROUND: Atherosclerotic renal artery stenosis (ARAS) is associated with progressive loss of renal function and is one of the most important causes of renal failure in the elderly. Current treatment includes restoration of the renal arterial lumen by endovascular stent placement. However, this

  11. Permanent Pacemaker-Induced Superior Vena Cava Syndrome: Successful Treatment by Endovascular Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela; Carbonell, Miguel A.; Garcia, Lorenzo Garcia

    2003-01-01

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later

  12. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  13. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    International Nuclear Information System (INIS)

    Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan

    2005-01-01

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series

  14. Air cholangiography in endoscopic bilateral stent-in-stent placement of metallic stents for malignant hilar biliary obstruction.

    Science.gov (United States)

    Lee, Jae Min; Lee, Sang Hyub; Jang, Dong Kee; Chung, Kwang Hyun; Park, Jin Myung; Paik, Woo Hyun; Lee, Jun Kyu; Ryu, Ji Kon; Kim, Yong-Tae

    2016-03-01

    Although endoscopic bilateral stent-in-stent (SIS) placement of self-expandable metallic stents (SEMS) is one of the major palliative treatments for unresectable malignant hilar biliary obstruction, post-endoscopic retrograde cholangiopancreatography (ERCP) cholangitis can occur frequently due to inadequate drainage, especially after contrast injection into the biliary tree. The aim of this study is to evaluate the efficacy and safety of air cholangiography-assisted stenting. This study included 47 patients with malignant hilar biliary obstruction who underwent endoscopic bilateral SEMS placement using the SIS technique. They were divided into two groups, air (n = 23) or iodine contrast (n = 24) cholangiography. We retrospectively compared comprehensive clinical and laboratory data of both groups. There were no significant differences found between the two groups with respect to technical success (87% versus 87.5%, air versus contrast group, respectively), functional success (95% versus 95.2%), 30-day mortality (8.3% versus 8.7%) and stent patency. Post-ERCP adverse events occurred in 5 (21.7%) of the patients in the air group and 8 (33.3%) of the patients in the contrast group. Among these, the rate of cholangitis was significantly lower in the air group (4.8% versus 29.2%, p = 0.048). In multivariate analysis, air cholangiography, technical success and a shorter procedure time were significantly associated with a lower incidence of post-ERCP cholangitis. Air cholangiography-assisted stenting can be a safe and effective method for endoscopic bilateral SIS placement of SEMS in patients with malignant hilar biliary obstruction.

  15. PTA and stenting for various types of Budd-Chiari syndrome

    International Nuclear Information System (INIS)

    Zhang Xinbao

    2011-01-01

    Objective: To investigate and evaluate PTA and stenting for various types of Budd-Chiari syndrome (BCS). Methods: 89 patients with BCS were diagnosed and treated during 7 years. The interventional procedures included: Percutaneous balloon dilatation (PBD) of inferior vena cava (IVC), PBD and stent placement for IVC, hepatic vein angioplasty via trans jugular vein, hepatic vein angioplasty via transhepatic and trans jugular approach, accessory hepatic vein angioplasty, percutaneous dual balloon dilatation for IVC and hepatic vein, and percutanous dual stent placement for IVC and hepatic vein. Results: The achievement ratio of PTA and stent placement was 96% and the mortality was 0%. The serious complication of PTA and stent placement of BCS was penetration into the pericardium, endovascular stent migration into right atrium. Conclusion: 1. PTA is a reliable procedures in treating type I a, II and III BCS, and TIPPS is useful for type I b BCS. But PTA and stenting is necessary for patients with type IV BCS. 2. Thrombolysis is needed for patients with type III, IV BCS. 3. Guiding of Color Doppler Ultrasound can improve the success of percutanous hepatic vein and reduce complications. (authors)

  16. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  17. cancerous esophagotracheal fistula: treatment of placement with covered self-expanding metallic stent

    International Nuclear Information System (INIS)

    Han Xinwei; Li Tianxiao; Wang Ruilin; Fan Qingxia

    1997-01-01

    Purpose: To treat the esophagotracheal fistula that was the main cause of death in patients with esophageal carcinoma, the placement of the stent was studied. Materials and methods: Under the fluoroscopic guidance, 28 stents (5 stents made in USA and 23 in China) were successfully implanted in all the 28 patients with esophagotracheal fistula. Results: The aphagia of the patients was greatly improved and a normal diet could be swallowed at once after the placement of the stents. The 27 cases of inhalation pneumonia that caused by the fistula was recovered. Conclusion: The result indicated that the treatment with the placement of the covered self-expanding stent is simple, safe, and effective for most patients with aphagia and pneumonia due to esophagotracheal fistula

  18. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  19. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-01-01

    Abstract Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group. PMID:26200641

  20. Temporary placement of stent grafts in postsurgical benign biliary strictures: a single center experience.

    Science.gov (United States)

    Vellody, Ranjith; Willatt, Jonathon M; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  1. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B [Division of Interventional Radiology, University of Michigan, Ann Arbor (United States)

    2011-11-15

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  2. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    International Nuclear Information System (INIS)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  3. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  4. Benign tracheobronchial stenoses: changes in short-term and long-term pulmonary function testing after expandable metallic stent placement.

    Science.gov (United States)

    Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L

    2002-01-01

    To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.

  5. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    International Nuclear Information System (INIS)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan

    2004-01-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications

  6. Placement of an implantable port catheter in the biliary stent: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Gi Young; Lee, Im Sick; Choi, Won Chan [Asan Medical Center, Seoul (Korea, Republic of)

    2004-04-01

    To investigate the feasibility of port catheter placement following a biliary stent placement. We employed 14 mongrel dogs as test subject and after the puncture of their gaIl bladders using sonographic guidance, a 10-mm in diameter metallic stent was placed at the common duct. In 12 dogs, a 6.3 F port catheter was placed into the duodenum through the common duct and a port was secured at the subcutaneous space following stent placement. As a control group, an 8.5 F drain tube was placed into the gallbladder without port catheter placement in the remaining two dogs. Irrigation of the bile duct was performed every week by injection of saline into the port, and the port catheter was replaced three weeks later in two dogs. Information relating to the success of the procedure, complications and the five-week follow-up cholangiographic findings were obtained. Placement of a biliary stent and a port catheter was technically successful in 13 (93%) dogs, while stent migration (n=3), gallbladder rupture (n=1) and death (n=5) due to subcutaneous abscess and peritonitis also occurred. The follow-up was achieved in eight dogs (seven dogs with a port catheter placement and one dog with a drain tube placement). Irrigation of the bile duct and port catheter replacement were successfully achieved without any complications. Cholangiograms obtained five weeks after stent placement showed diffuse biliary dilation with granulation tissue formation. However, focal biliary stricture was seen in one dog with stent placement alone. Placement of a port catheter following biliary stent placement seems to be feasible. However, further investigation is necessary to reduce the current complications.

  7. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  8. Self-Expandable Metallic Stent Placement in Malignant Gastric Outlet Obstruction: A Comparison Between 2 Brands of Stents.

    Science.gov (United States)

    Ye, Bing-Wei; Lee, Kuei-Chuan; Hsieh, Yun-Cheng; Li, Chung-Pin; Chao, Yee; Hou, Ming-Chih; Lin, Han-Chieh

    2015-07-01

    Malignant gastric outlet obstruction is a late complication of intraabdominal malignancy. Self-expandable metallic stent placement has been a safe palliative treatment to relieve obstructive symptoms. We aimed to assess the efficacy and safety of metallic stents in our patients and analyzed the clinical outcome of different brands. Seventy-one patients with inoperable gastric outlet obstruction receiving WallFlex enteral stents (WallFlex group) or Bonastents (Bonastent group) since April 2010 were analyzed retrospectively. The overall technical and clinical success rates of stent placement were 100% and 93%, respectively. The baseline characteristics and clinical outcomes including procedure-related complications, restenosis, and reintervention rates were comparable between the 2 groups. However, the Bonastent group had a higher rate of stent fracture than the WallFlex group (13.3% vs 0%, P = 0.03). The mean duration of overall stent patency was 132.7 days. The mean duration of survival was 181.9 days. Resumption of regular diet or low residual diet at day 7 after stent insertion predicted stent patency (hazard ratio [HR]: 0.28, P = 0.01). Cancer with gastric origin (HR: 0.25, P = 0.045) and poststent chemotherapy (HR: 0.38, P = 0.006) predicted lower mortality; however, peritoneal carcinomatosis (HR: 3.09, P = 0.04) correlated with higher mortality. Metallic stent placement is a safe and effective method for relieving gastric outlet obstruction. Except higher rate of stent fracture in the Bonastent group, there is no significant difference in clinical outcomes between the Bonastent group and the WallFlex group.

  9. Functional effects of renal artery stent placement on treated and contralateral kidneys.

    NARCIS (Netherlands)

    Leertouwer, T.C.; Derkx, F.H.M.; Pattynama, P.M.; Deinum, J.; Dijk, L.C. van; Schalekamp, M.A.D.H.

    2002-01-01

    BACKGROUND: This study examined the effects of stent placement for renal artery stenosis on the function of treated and contralateral kidneys. METHODS: Eighteen patients who underwent stent placement for unilateral renal artery stenosis presenting with hypertension and/or renal failure were studied

  10. Extra-anatomic bypass for recurrent abdominal aortic and renal in-stent stenoses following radiotherapy for neuroblastoma.

    Science.gov (United States)

    Luehr, Maximilian; Siepe, Matthias; Beyersdorf, Friedhelm; Schlensak, Christian

    2009-04-01

    We describe the case of an 11-year-old girl with an abdominal neuroblastoma which was operated and intraoperatively irradiated nine years ago. After six years, she developed stenoses of the infrarenal abdominal aorta and both renal arteries. Initial treatment of the stenosed vessels comprised endovascular balloon dilatations and repeated stent-graft implantations, including drug eluting stents. However, severe in-stent stenoses occurred during follow-up and the girl developed acute renal failure. Open surgery was performed with two extra-anatomic bypasses, a thoracic-to-abdominal aortic bypass and a left iliac-to-renal bypass, on an urgent basis. The postoperative course was uneventful and the patient was discharged home two weeks after the operation with full recovery of renal function. We conclude that endovascular stent-graft placement in children can only be a palliative treatment due to outgrowing of the stent-graft and the potential risk of re-stenosis, especially after a history of irradiation. Vascular surgery with placement of extra-anatomic bypasses will provide a definite treatment.

  11. Percutaneous transcholecystic approach for an experiment of biliary stent placement: an experimental study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok [Medical School of Gachon, Inchon (Korea, Republic of); Song, Ho Young; Lim, Jin Oh; Ko, Gi Young; Sung, Kyu Bo; Kim, Tae Hyung; Lee, Ho Jung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-06-01

    To determine, in an experimental study of biliary stent placement, the usefulness and safety of the percutaneous transcholecystic approach and the patency of a newly designed biliary stent. A stent made of 0.15-mm-thick nitinol wire, and 10 mm in diameter and 2 cm in length, was loaded in an introducer with an 8-F outer diameter. The gallbladders of seven mongrel dogs were punctured with a 16-G angiocath needle under sonographic guidance, and cholangiography was performed. After anchoring the anterior wall of the gallbladder to the abdominal wall using a T-fastener, the gallbladder body was punctured again under fluoroscopic guidance. The cystic and common bile ducts were selected using a 0.035-inch guide wire and a cobra catheter, and the stent was placed in the common bile duct. Post-stenting cholangiography was undertaken, and an 8.5-F drainage tube was inserted in the gallbladder. Two dogs were followed-up and sacrificed at 2,4 and 8 weeks after stent placement, respectively, and the other expired 2 days after stent placement. Follow-up cholangiograms were obtained before aninmal was sacrified, and a pathologic examination was performed. Stent placement was technically successful in all cases. One dog expired 2 days after placement because of bile peritonitis due to migration of the drainage tube into the peritoneal cavity, but the other six remained healthy during the follow-up period. Cholangiography performed before the sacrifice of each dog showed that the stents were patent. Pathologic examination revealed the proliferation of granulation tissue at 2 weeks, and complete endothelialization over the stents by granulation tissue at 8 weeks. Percutaneous transcholecystic biliary stent placement appears to be safe, easy and useful. After placement, the stent was patent during the follow-period.

  12. Risk factors for technical failure of endoscopic double self-expandable metallic stent placement by partial stent-in-stent method.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Toyokawa, Yoshihide; Otani, Koichi; Kuwatani, Masaki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-01-01

    Endoscopic double self-expandable metallic stent (SEMS) placement by the partial stent-in-stent (PSIS) method has been reported to be useful for the management of unresectable hilar malignant biliary obstruction. However, it is technically challenging, and the optimal SEMS for the procedure remains unknown. The aim of this study was to identify the risk factors for technical failure of endoscopic double SEMS placement for unresectable malignant hilar biliary obstruction (MHBO). Between December 2009 and May 2013, 50 consecutive patients with MHBO underwent endoscopic double SEMS placement by the PSIS method. We retrospectively evaluated the rate of successful double SEMS placement and identified the risk factors for technical failure. The technical success rate for double SEMS placement was 82.0% (95% confidence interval [CI]: 69.2-90.2). On univariate analysis, the rate of technical failure was high in patients with metastatic disease and unilateral placement. Multivariate analysis revealed that metastatic disease was a significant risk factor for technical failure (odds ratio: 9.63, 95% CI: 1.11-105.5). The subgroup analysis after double guidewire insertion showed that the rate of technical success was higher in the laser-cut type SEMS with a large mesh and thick delivery system than in the braided type SEMS with a small mesh and thick delivery system. Metastatic disease was a significant risk factor for technical failure of double SEMS placement for unresectable MHBO. The laser-cut type SEMS with a large mesh and thin delivery system might be preferable for the PSIS procedure. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  13. Stone extraction balloon-guided repeat self-expanding metal stent placement

    Institute of Scientific and Technical Information of China (English)

    Hyung; Hun; Kim; Jeong; Seop; Moon; Soo; Hyung; Ryu; Jung; Hwan; Lee; You; Sun; Kim

    2010-01-01

    Self-expanding metal stent (SEMS) placement offers safe and effective palliation in patients with upper gastrointestinal obstruction due to a malignancy. Well described complications of SEMS placement include tumor growth, obstruction, and stent migration. SEMS occlusions are treated by SEMS redeployment, argon plasma coagulation application, balloon dilation, and surgical bypass. At our center, we usually place the second SEMS into the first SEMS if there is complete occlusion by the tumor. We discovered a...

  14. Self-Expandable Metallic Stent Placement for the Palliation of Esophageal Cancer.

    Science.gov (United States)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho Young; Kim, Pyeong Hwa; Park, Jung Hoon

    2017-07-01

    Esophageal stents have been used to palliate patients with dysphagia caused by esophageal cancer. Early rigid plastic prostheses have been associated with a high risk of complications. However, with the development of self-expanding stents, it has developed into a widely accepted method for treating malignant esophageal strictures and esophagorespiratory fistulas (ERFs). The present review covers various aspects of self-expanding metallic stent placement for palliating esophageal cancer, including its types, placement procedures, indications, contraindications, complications, and some of innovations that will become available in the future. © 2017 The Korean Academy of Medical Sciences.

  15. Silicone stent placement for primary tracheal amyloidosis accompanied by cartilage destruction.

    Science.gov (United States)

    Ryu, Duck Hyun; Eom, Jung Seop; Jeong, Ho Jung; Kim, Jung Hoon; Lee, Ji Eun; Jun, Ji Eun; Song, Dae Hyun; Han, Joungho; Kim, Hojoong

    2014-06-01

    Primary tracheal amyloidosis (PTA) can lead to airway obstructions, and patients with severe PTA should undergo bronchoscopic interventions in order to maintain airway patency. Focal airway involvements with amyloidosis can only be treated with mechanical dilatation. However, the PTA with diffused airway involvements and concomitant cartilage destructions requires stent placement. Limited information regarding the usefulness of silicone stents in patients with PTA has been released. Therefore, we report a case of diffused PTA with tracheomalacia causing severe cartilage destruction, which is being successfully managed with bronchoscopic interventions and silicone stent placements.

  16. Thrombin Injection Failure with Subsequent Successful Stent-Graft Placement for the Treatment of an Extracranial Internal Carotid Pseudoaneurysm in a 5-Year-Old Child

    International Nuclear Information System (INIS)

    Garcia-Monaco, R. D.; Kohan, A. A.; Martinez-Corvalan, M. P.; Cacchiarelli, N.; Peralta, O.; Wahren, C. G.

    2012-01-01

    Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.

  17. Stent placement of gastroenteric anastomoses formed by magnetic compression.

    Science.gov (United States)

    Cope, C; Clark, T W; Ginsberg, G; Habecker, P

    1999-01-01

    To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression. Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals. Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection. Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.

  18. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  19. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  20. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    International Nuclear Information System (INIS)

    Fu, Qining; Meng, Xiyun; Li, Fenghe; Wang, Xuehu; Cheng, Jun; Huang, Wen; Ren, Wei; Zhao, Yu

    2015-01-01

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment

  1. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qining, E-mail: cqmufqn@163.com; Meng, Xiyun, E-mail: 383274177@qq.com; Li, Fenghe, E-mail: lfh-cqmu@gmail.com; Wang, Xuehu, E-mail: 184037696@qq.co; Cheng, Jun, E-mail: cqdcj@163.com; Huang, Wen, E-mail: dhuangwen@hotmail.com; Ren, Wei, E-mail: renwei9771@yahoo.com.cn; Zhao, Yu, E-mail: zhaoyu-cqmu@126.com [The First Affiliated Hospital of Chongqing Medical University, Department of Vascular Surgery (China)

    2015-06-15

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

  2. Endovascular treatment of three traumatic lesions of the vertebral artery

    International Nuclear Information System (INIS)

    Galvis, Victor Raul; Medina V, Francisco Jose

    2007-01-01

    The purpose is to expose the results of the endovascular treatment of three traumatic lesions of the vertebral artery. Methods: in the period from October 2005 to May 2006, three patients with traumatic lesions in the vertebral artery were treated by endovascular therapy with an age average of 32 years. All the procedures were carried out using subtraction digital angiography under anesthesiology supervision and were started with a 5,000 IU heparin bolus, previous antiplatelet medication with clopidogrel. For the treatment of the lesions covered stents and coils were used. results: there were three documented cases of traumatic lesions of the vertebral artery treated by endovascular therapy, in two cases arteriovenous fistulas were identified (between vertebral artery and internal jugular vein) with associated pseudo aneurysms, and in one case a pseudo aneurysm without fistula was found. The first patient was treated with placement of a covered stent, in a second patient the lesion was occluded with coils and a third patient required stent and coils with satisfactory repair of the lesions. Complications were not presented as a result of the procedures. Conclusions: the endovascular treatment for traumatic lesions of the vertebral artery is an alternative with minimum morbidity and reasonable costs avoiding the open surgery and conserving the permeability of the vessel when it is possible

  3. Radiologic Placement of Uncovered Stents for the Treatment of Malignant Colonic Obstruction Proximal to the Descending Colon

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jehong; Kwon, Se Hwan, E-mail: Kwon98@khu.ac.kr [Kyung Hee University, Department of Radiology, College of Medicine (Korea, Republic of); Lee, Chang-Kyun [Kyung Hee University, Department of Internal Medicine, College of Medicine (Korea, Republic of); Park, Sun Jin [Kyung Hee University, Department of Surgery, College of Medicine (Korea, Republic of); Oh, Ji Young [Kyung Hee University Hospital at Gangdong, Department of Radiology (Korea, Republic of); Oh, Joo Hyeong [Kyung Hee University, Department of Radiology, College of Medicine (Korea, Republic of)

    2017-01-15

    PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructive symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.

  4. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    Science.gov (United States)

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  5. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Petrocelli, Francesco; Seitun, Sara; Robaldo, Alessandro; Mazzei, Raffaele

    2011-01-01

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  6. A Fast Placement Technique for Covered Tracheobronchial Stents in Patients with Complicated Esophagorespiratory Fistulas

    International Nuclear Information System (INIS)

    Kishi, Kazushi; Nakao, Taisei; Goto, Hironobu; Kimura, Masashi; Sonomura, Tetsuo; Yamanaka, Noboru; Nanjo, Kishio; Sato, Morio

    2005-01-01

    Purpose. To test an endotracheal placement procedure for malignant esophagorespiratory fistula when endoesophageal placement is inapplicable. Methods. We report on patients with malignant esophagorespiratory fistula to which endoesophageal approaches were complicated with a complete obstruction of the hypopharynx, a collapsible tracheobronchus, or a previously placed endoesophageal stents. Gore-Tex membrane-covered Z-stents were deployed in the trachea using a coaxial introducer system in three patients. A Dumon tube was deployed in the bronchus over the bronchofiberscope in one patient. Results. All fistula were completely sealed by the endotracheal or endobronchial stenting. Symptomatic and clinical improvements were immediate obtained. Conclusion. Endotracheal or endobronchial covered stent placement is thought to be an effective alternative method for sealing esophagorespiratory fistula

  7. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents

    International Nuclear Information System (INIS)

    Teichgräber, Ulf K.; Bucourt, Maximilian de

    2012-01-01

    Objectives: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). Materials and methods: The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. Results: The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. Conclusion: VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system.

  8. Analysis of the placement of multiple metallic stents in the treatment of hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Lu Zaiming; Liang Hongyuan; Guo Qiyong; Wen Feng; Liu Zhaoyu; Zhang Jun

    2007-01-01

    Objective: To evaluate the clinical efficacy of multiple stents placement in the management of hilar cholangiocarcinoma, especially in the complex cases of which the hepatic ducts are invaded. Methods: Forty-five consecutive patients with hilar cholangiocarcinoma were treated with percutaneous transhepatic placement of two or three self-expandable metallic endoprostheses. The cause of hilar obstructions in these patients were all cholangiocarcinoma, including Bismuth classification type II (n 12), IIIa (n 17), IIIb (n 10), and IV (n 6). Two or 3 stents were placed in the configuration of T, Y or X over the strictures. Results: Stent placement with 2 or 3 endoprostheses was successful in all patients. All patients showed significant decrease in serum bilirubin level. The mortality rate within 30 days of stent placement was 2.2% (1/45). The mean survival and stent patency times were 215.3 d (26- 516 d) and 181.5 d (26-473 d), respectively. Conclusion: Deploying of multiple metallic stents is an effective method to treat complex hilar cholangiocarcinoma, especially for the cases of which hepatic ducts are invaded; the hepatic ducts should be drained as much as possible. (authors)

  9. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  10. Predictive factors for the failure of endoscopic stent-in-stent self-expandable metallic stent placement to treat malignant hilar biliary obstruction.

    Science.gov (United States)

    Sugimoto, Mitsuru; Takagi, Tadayuki; Suzuki, Rei; Konno, Naoki; Asama, Hiroyuki; Watanabe, Ko; Nakamura, Jun; Kikuchi, Hitomi; Waragai, Yuichi; Takasumi, Mika; Sato, Yuki; Hikichi, Takuto; Ohira, Hiromasa

    2017-09-14

    To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents (SEMSs). This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography (ERCP) procedures between the two groups. The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices (ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve (sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.

  11. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    International Nuclear Information System (INIS)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho; Ko, Ji Ho; Jeong, Kyung Soon

    2007-01-01

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

  12. Covered self-expandable metallic stent placement for a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Woon Ha; Jung, Gyoo Sik; Kim, Kyu Jong; Lee, Sang Ho [Gospel Hospital, College of Medicine, Kosin University, Busan (Korea, Republic of); Ko, Ji Ho [Masan Samsung Medical Center, Sungkyunkwan University School of University, Masan (Korea, Republic of); Jeong, Kyung Soon [University of Ulsan Colleg of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-09-15

    To evaluate the technical feasibility and clinical effectiveness of stent placement for the treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer. Under fluoroscopic guidance, one or two covered stents were placed in 20 consecutive patients (age range, 44-75 years) with an anastomotic stricture due to a recurrent gastric malignancy. Before stent placement, all patients had severe nausea and recurrent vomiting after ingestion. Stent placement was technically successful for all patients, and no procedural complications occurred. After stent placement, 18 of 20 (90.0%) patients were able to ingest at least a liquid diet and had a markedly decreased incidence of vomiting. During the follow-up of 2-116 weeks (mean, 25.5 weeks), stent migration occurred in two patients (10.0%) on one day after the procedure. All patients with stent migration were treated successfully by means of placing a second stent. Three patients showed a recurrence of the stricture due to tumor overgrowth; two of the patients were treated with coaxial placement of a second stent. Another patient refused additional management. Covered self-expandable metallic stent placement seems to be technically feasible and effective for palliative treatment of a post-operative malignant anastomotic stricture secondary to recurrent gastric cancer.

  13. Short-term curative effect of endovascular stent-graft treatment for aortic diseases in China: a systematic review.

    Directory of Open Access Journals (Sweden)

    Siwen Wang

    Full Text Available INTRODUCTION: We analyzed the short-term efficacy of endovascular treatment for aortic diseases by summarizing all available published data on endovascular stent-graft treatment for abdominal aortic aneurysm (AAA, thoracic aortic aneurysm (TAA, type A aortic dissection (type A AD and type B aortic dissection (type B AD in China. METHODS: We performed a systematic analysis of 935 published series on retrograde endovascular treatment for aortic diseases in China from January 1996 to November 2010. Based on the inclusion criteria, 159 studies, involving a total of 5531 patients, were included. RESULTS: There were no significant differences in procedural success among the studies (P>0.05. The rates of overall neurologic complications and stroke were significantly different in all two-group comparisons (P0.05. A significant difference was noted between the 30-day mortality rate of the type A AD patients and the AAA or type B AD patients (P<0.05. CONCLUSION: Endovascular stent-graft is a feasible and safe treatment for aortic diseases, with high procedural success and low incidences of post-procedural complications and short-term mortality. Endovascular treatment for AAA and type B AD is more efficient than for type A AD and TAA.

  14. Bilateral spontaneous internal carotid artery dissection managed with endovascular stenting – A case report

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Agarwala

    2016-09-01

    We describe a patient with ischemic stroke from spontaneous bilateral ICAD with completely occluded left ICA. Having failed medical therapy with antiplatelets and anticoagulants due to extensive loss of carotid vascular supply, he was managed successfully with endovascular stenting with good neurological recovery.

  15. Treatment of malignant central airway obstruction with Y-type metallic stent placement under general anaesthesia

    International Nuclear Information System (INIS)

    Yang Zhengqiang; Shi Haibin; Zhou Weizhong; Leng Derong; Li Linsun

    2010-01-01

    Objective: To report the clinical experience in treating malignant central airway obstruction with the placement of a domestic Y-shaped stent under general anaesthesia. Methods: The placement of a domestic Y-stent under general anaesthesia together with tracheal intubation was performed in three male patients of central lung cancer with the involvement of carina and subsequent malignant airway stenosis. The combination of Y-stent delivering and tracheal intubation had not been reported in the literature so far, so the technical experience was introduced in this paper. Results: The placement of Y-stent was successfully completed in all 3 patients. The whole procedure was smoothly carried out with no severe complications. After the operation the dyspnea was markedly relieved in all the patients. Conclusion: As a safe and effective treatment for malignant central airway obstructions, the placement of a domestic Y-stent under general anaesthesia can reduce patient's discomfort during the stent delivering process. A large cohort of patients is required in order to evaluate the long-term efficacy and related complications of this technique. (authors)

  16. Temporary placement of metallic stent could lead to long-term benefits for benign tracheobronchial stenosis.

    Science.gov (United States)

    Zhou, Guo-Wu; Huang, Hai-Dong; Sun, Qin-Ying; Xiong, Ye; Li, Qiang; Dong, Yu-Chao; Zhang, Wei

    2015-12-01

    The permanent placement of metallic stent for benign tracheobronchial stenosis (BTS) was controversial. This study was conducted to evaluate the long-term outcomes of temporary placement of metallic stent for BTS. The BTS patients who received temporary placement of retrievable self-expanded metallic stents were included between 2008 and 2011. Pre-stenting and follow-up respiratory status was analyzed. And symptom recurrence-free survival (SRFS) was assessed. A total of 49 stents were successfully temporarily placed in 40 consecutive BTS patients whose etiologies included endobronchial tuberculosis (EBTB) (n=22), post-tracheostomy stenosis (n=10), post-intubation stenosis (n=6) and post radiotherapy stricture (n=2). All stents were removed integrally after a median 18 days' stenting period, without major complications. During the median 27 months follow-up period after stent removal, a total of 22 patients were free of recurrence. And the overall 3-year SRFS rate was 52.0%. According to the etiology, the 3-year SRFS rates were 59.1% and 42.9% in the patients with EBTB and non-EBTB, respectively. Compared with pre-stenting, the follow-up internal diameter of stricture, Hugh-Jones scale, 6-minute walk test (6MWT) and percentage of forced expiratory volume in one second (FEV1%) were significantly improved. Multivariate analysis suggested that granulation tissue growth and tracheobronchial malacia might be independent factors of poor prognosis. Temporary placement of retrievable metallic stent may be an alternative treatment for BTS patients.

  17. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de medecine interne, Pole Pluridisciplinaire de Medecine (France); Thony, Frederic, E-mail: FThony@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de reanimation, Pole Medecine Aiguee Communautaire (France); Rodiere, Mathieu, E-mail: MRodiere@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Monnin-Bares, Valerie, E-mail: v-monnin@chu-montpellier.fr [CHRU Arnaud de Villeneuve, Imagerie Medicale Thoracique Cardiovasculaire (France); Ferretti, Gilbert R., E-mail: GFerretti@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Vesin, Aurelien; Moro-Sibilot, Denis, E-mail: DMoro.pneumo@chu-grenoble.fr [University Grenoble 1 e Albert Bonniot Institute, Inserm U823 (France)

    2013-02-15

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  18. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    International Nuclear Information System (INIS)

    Fagedet, Dorothée; Thony, Frederic; Timsit, Jean-François; Rodiere, Mathieu; Monnin-Bares, Valérie; Ferretti, Gilbert R.; Vesin, Aurélien; Moro-Sibilot, Denis

    2013-01-01

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  19. Long-term success of endovascular treatment of benign superior vena cava occlusion with chylothorax and chylopericardium

    Energy Technology Data Exchange (ETDEWEB)

    Veroux, Pierfrancesco; Veroux, Massimiliano; Bonanno, Maria Giovanna; Tumminelli, Maria Giuseppina [Department of Surgery and Transplantation, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy); Baggio, Elda [Department of Surgery and Gastroenterological Sciences, University Hospital of Verona (Italy); Petrillo, Giuseppe [Department of Radiology, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy)

    2002-07-01

    The most likely etiology of benign obstruction of the superior vena cava (SVC) include fibrosing mediastinitis and iatrogenic etiologies such as sclerosis and obstruction caused by pacemakers and central venous catheter. Percutaneous stenting of SVC has been used with success both in malignant and benign superior vena cava syndrome; however, long-term follow-up of endovascular procedures is not well known. We present a case of a patient with complete occlusion of SVC of benign etiology, presenting dramatically with bilateral chylothorax and chylopericardium with cardiac tamponade, who underwent successful vena caval revascularization with thrombolytic therapy and placement of self-expanding metallic stent. The 42-month follow-up could encourage endovascular procedures even in SVC syndrome of benign etiology. (orig.)

  20. Tratamento endovascular de ruptura traumática da aorta torácica descendente Endovascular treatment of traumatic descending thoracic aortic rupture

    Directory of Open Access Journals (Sweden)

    João Roberto Breda

    2007-06-01

    Full Text Available Paciente do sexo feminino, 55 anos de idade, vítima de atropelamento, foi admitida em unidade de emergência, onde se realizou o diagnóstico clínico, radiológico e tomográfico de ruptura traumática da aorta torácica descendente. Diante do achado, a paciente foi encaminhada para tratamento endovascular com colocação de endoprótese auto-expansível (stent pela artéria femoral. O tratamento obteve sucesso, evidenciado pela exclusão da lesão localizada previamente no istmo aórtico. O tratamento endovascular tem sido indicado nas afecções de aorta torácica descendente com bons resultados iniciais. Na ruptura traumática de aorta, a terapêutica endovascular representa uma alternativa aceitável, especialmente devido aos riscos do tratamento operatório convencional.A 55-year-old, female patient who was run over by a motor vehicle was admitted at an emergency room. Clinical, radiological and tomographic diagnosis of traumatic descending aortic thoracic rupture was performed. The patient was referred for endovascular treatment with placement of a self-expandable stent through the femoral artery. Treatment was successful, with exclusion of the lesion previously located in the aortic isthmus. Endovascular treatment has been indicated in the treatment of descending thoracic aortic diseases, with good initial results. In case of traumatic aortic rupture, endovascular treatment is a feasible alternative, especially due to risks offered by the conventional surgical treatment.

  1. Safety and efficacy of transhepatic and transsplenic access for endovascular management of portal vein complications after liver transplantation.

    Science.gov (United States)

    Ohm, Joon-Young; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu

    2017-09-01

    The purpose of this article is to evaluate and compare the safety and efficacy of endovascular management of the portal vein (PV) via percutaneous transsplenic access versus percutaneous transhepatic access in liver transplantation (LT) recipients. A total of 18 patients who underwent endovascular management of PV via percutaneous transhepatic (n = 8) and transsplenic (n = 10) access were enrolled. Transsplenic access was chosen if the spleen was located in a normal position, the splenic vein (SpV) was preserved, and the target lesion did not involve confluence of the superior mesenteric and SpVs. Accessibility of the percutaneous transsplenic puncture was confirmed via ultrasound (US) in the angiography suite. All procedures were performed under local anesthesia. Percutaneous transhepatic or transsplenic access was performed using a 21-gauge Chiba needle under US and fluoroscopic guidance, followed by balloon angioplasty, stent placement, or variceal embolization. The access tract was embolized using coils and a mixture (1:2) of glue and ethiodized oil. Transhepatic or transsplenic access was successfully achieved in all patients. A total of 12 patients underwent stent placement; 3 had balloon angioplasty only; 2 had variceal embolization only; and 1 had variceal embolization followed by successful stent placement. Regarding major complications, 1 patient experienced a SpV tear with extravasation during transsplenic balloon angioplasty, which was successfully managed using temporary balloon inflation, followed by transfusion. Clinical success was achieved in 9 of 11 (82%) patients who exhibited clinical manifestations. The remaining 7 patients who underwent prophylactic endovascular management were healthy. In conclusion, endovascular management of PV via percutaneous transsplenic access is a relatively safe and effective alternative that does not damage the liver grafts of LT recipients. Liver Transplantation 23 1133-1142 2017 AASLD. © 2017 by the American

  2. Adhesion and endothelialization of endothelial cells on the surface of endovascular stents by the novel rotational culture of cells

    International Nuclear Information System (INIS)

    Tang Chaojun; Wang Guixue; Cao Yi; Wu Xue; Xie Xiang; Xiao Li

    2008-01-01

    Recent researches indicate that the initial event in the implantation of endovascular stents involves mechanical injury to the vessel wall. Confluent endothelialization of vascular grafts in vitro before implantation has been suggested as a way to reduce injury of the blood vessel. The purpose of this study is to establish a useful way to improve the adhesion of endothelial cells and accelerate endothelialization on the surface of endovascular stents by a novel rotational culture device. Numerical simulation was used to predict the shear stress on the surface of stents. The number of cellular adhesion was calculated by cell counting, the cell growth was observed by scanning electron microscope and fluorescence microscope. Numerical simulation results showed that the stents was exposed to shear stress of 2.66 x 10 -3 to 8.88 x 10 -2 Pa. Rotational culture of human umbilical vein endothelial cells could enhance the adhesion of cells and accelerate endothelialization on the surface of stents when the culture conditions for EC adhesion were intermediate rotation speed, higher dynamic incubation times, lower cell densities

  3. A randomized trial comparing primary angioplasty versus stent placement for symptomatic intracranial stenosis

    Science.gov (United States)

    Qureshi, Adnan I; Chaudhry, Saqib A; Siddiq, Farhan; Majidi, Shahram; Rodriguez, Gustavo J; Suri, M Fareed K

    2013-01-01

    Background: Both primary angioplasty alone and angioplasty with a self-expanding stent have been compared in non-randomized concurrent clinical studies that suggest equivalent results. However, there is no randomized trial that has compared the two procedures in patients with symptomatic high grade intracranial stenosis. Objective: The primary aim of the randomized trial was to compare the clinical and angiographic efficacy of primary angioplasty and angioplasty followed by stent placement in preventing restenosis, stroke, requirement for second treatment, and death in patients with symptomatic intracranial stenosis. Methods: The study prospectively evaluated efficacy and safety of the two existing neurointerventional techniques for treatment of moderate intracranial stenosis (stenosis ≥ 50%) with documented failure of medical treatment or severe stenosis (≥70%) with or without failure of medical treatment. Results: A total of 18 patients were recruited in the study (mean age [±SD] was 64.7 ± 15.1 years); out of these, 12 were men. Of these 18, 10 were treated with primary angioplasty and 8 were treated with angioplasty followed by self-expanding stent. The technical success rates of intracranial angioplasty and stent placements defined as ability to achieve <30% residual stenosis when assessed by immediate post-procedure angiography was 5 of 10 and 5 of 8 patients, respectively. The total fluoroscopic time (mean [±SD]) was lower in patients undergoing primary angioplasty 37 [±11] min versus those undergoing angioplasty followed by self-expanding stent 42 [±15] min, P = 0.4321. The stroke and death rate within 1 month was very low in both patient groups (1 of 10 versus 0 of 8 patients). One patient randomized to stent placement continued to have recurrent ischemic symptoms requiring another angioplasty in the vertebral artery on post-procedure Day 2. Conclusions: The trial suggests that a randomized trial comparing primary angioplasty to angioplasty

  4. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  5. Endovascular Management of Infected Femoral Artery Pseudoaneurysms in High-Risk Patients: A Case Series

    Energy Technology Data Exchange (ETDEWEB)

    D’Oria, Mario, E-mail: mario.doria88@outlook.com; Sgorlon, Giada; Calvagna, Cristiano; Zamolo, Francesca; Chiarandini, Stefano; Adovasio, Roberto; Griselli, Filippo [University Hospital of Cattinara, Vascular and Endovascular Surgery Unit (Italy)

    2017-04-15

    We report our experience with the urgent treatment of two high-risk patients with infected femoral artery pseudoaneurysms (IFAPs) with the placement of a self-expandable covered stent (SECS). In both cases, there was no perioperative mortality and the aneurysm exclusion was successful without early or late stent thrombosis/stent fracture nor acute or chronic limb ischemia or limb loss. There was no recurrence of local or systemic infection during the follow-up period. Endovascular therapy represents a feasible treatment option for IFAPs in those patients for whom the risk of open surgical repair would be prohibitive, especially under urgent circumstances.

  6. Applying value stream mapping techniques to eliminate non-value-added waste for the procurement of endovascular stents.

    Science.gov (United States)

    Teichgräber, Ulf K; de Bucourt, Maximilian

    2012-01-01

    OJECTIVES: To eliminate non-value-adding (NVA) waste for the procurement of endovascular stents in interventional radiology services by applying value stream mapping (VSM). The Lean manufacturing technique was used to analyze the process of material and information flow currently required to direct endovascular stents from external suppliers to patients. Based on a decision point analysis for the procurement of stents in the hospital, a present state VSM was drawn. After assessment of the current status VSM and progressive elimination of unnecessary NVA waste, a future state VSM was drawn. The current state VSM demonstrated that out of 13 processes for the procurement of stents only 2 processes were value-adding. Out of the NVA processes 5 processes were unnecessary NVA activities, which could be eliminated. The decision point analysis demonstrated that the procurement of stents was mainly a forecast driven push system. The future state VSM applies a pull inventory control system to trigger the movement of a unit after withdrawal by using a consignment stock. VSM is a visualization tool for the supply chain and value stream, based on the Toyota Production System and greatly assists in successfully implementing a Lean system. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  7. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  8. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  9. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  10. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  11. Metallic stent placement in hemodialysis graft patients after insufficient balloon dilation

    International Nuclear Information System (INIS)

    Liang, Huei-Lung; Pan, Huay-Ben; Lin, Yih-Huie; Chen, Chiung-Yu; Lai, Pin-Hong; Yang, Chien-Fang; Chung, Hsiao-Min; Wu, Tung-Ho; Chou, Kang-Ju

    2006-01-01

    We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patents (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8-10mm in diameter and 40-80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates (±standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69%±9 and 88%±6,41% ±10 and 88%±6, 30%±10 and 77%±10, and 12%±8 and 61%±13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51%±16 and 86%±13 vs 45%±15 and 73%±13 at 6 months, and 25%±15 and 71%±17 vs 23%±17 and 73%±13 at 12 months (ρ = .436 and .224), respectively. Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen

  12. Endovascular repair of renal artery aneurysm with the multilayer stent – a short report

    Directory of Open Access Journals (Sweden)

    Vojko Flis

    2012-10-01

    in the main left renal artery involving all three major branches of the renal artery. Via a percutaneous femoral approach a multilayer stent was deployed without complications. Blood flow inside the sac was immediately and significantly reduced. All the renal branches remained patent. Conclusion: New multilayer fluid modulating stent concept appears to be a very useful and attractive alternative to surgery or other endovascular techniques for those RAA involving or very close to major branch vessels, especially in patients with very high risk of loosing the only viable kidney, as in our case.

  13. Brachytherapy for the prevention of neointimal hyperplasia in the canine inferior vena cava after stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Isota, Masayuki; Kaminou, Toshio; Sakai, Yukimasa; Nakamura, Kenji; Yamada, Ryusaku [Osaka City Univ. (Japan). Medical School

    2002-06-01

    The aim of this study was to evaluate the efficacy of brachytherapy for preventing neointimal hyperplasia in the inferior vena cava (IVC) after stent placement. Sixteen beagles underwent Z-stent placement in the IVC and the aorta. For 8 of 16 beagles, irradiation (15 Gy) was delivered endoluminally to the stented segments of each vessel immediately after stent placement using the {sup 192}Ir. All animals were sacrificed after 6 weeks for morphometric and histopathologic examination. Morphometrically, neointimal thickness in the IVC of the radiation group was significantly decreased compared with the control group as well as that in the aorta (p<0.05). Histopathologic findings showed the neointima in the IVC of the control group contained markedly organization of thrombus and neovascularization though that in the IVC of the radiation group consisted mainly of smooth muscle cells without organization of thrombus and neovascularization. From these data intravenous irradiation may prevent clinical restenosis after stent placement. (author)

  14. Tiny intracranial aneurysms: Endovascular treatment by coil embolisation or sole stent deployment

    International Nuclear Information System (INIS)

    Lu Jun; Liu Jiachun; Wang Lijun; Qi Peng; Wang Daming

    2012-01-01

    Purpose: Tiny intracranial aneurysms pose a significant therapeutic challenge for interventional neuroradiologists. The authors report their preliminary results of endovascular treatment of these aneurysms. Methods: Between January 2002 and December 2009, 52 tiny intracranial aneurysms (defined as ≤3 mm in maximum diameter) in 46 patients (22 men; mean age, 57.9 years) were treated by endosaccular coil embolisation or sole stent deployment in the parent artery. Of 52 aneurysms, 29 had ruptured and 23 remained unruptured. The initial angiographic results, procedural complications, and clinical outcomes were assessed at discharge. Imaging follow-up was performed with cerebral angiography. Results: One aneurysm coiling procedure failed because of unsuccessful micro-catheterization. Forty-three aneurysms were successfully coil embolized, of which complete occlusion was obtained in 14, subtotal occlusion in 18 and incomplete occlusion in 11. The other 8 aneurysms were treated by sole stent deployment in the parent artery. Procedural complications (2 intraprocedural ruptures and 3 thromboembolic events) occurred in 5 (9.6%) of 52 aneurysms, resulting in permanent morbidity in only 1 (2.2%, 1/46) patient. No rebleeding occurred during clinical follow-up (mean duration, 46.7 months). Of the 16 coiled aneurysms that receiving repetitive angiography, 6 initially completely and 3 subtotally occluded aneurysms remained unchanged, 4 initially subtotally and 3 incompletely occluded aneurysms progressed to total occlusion. Five sole stent deployed aneurysms received angiographic follow-up (mean duration, 10.0 months), of which 3 remained unchanged, 1 became smaller and 1 progressed to total occlusion. Conclusion: Endovascular treatment of tiny intracranial aneurysms is technical feasible and relatively safe. Coil embolisation seems to be effective in preventing early recanalisation, whereas sole stenting technique needs further investigation to determine its effectiveness.

  15. Malignant Hilar Biliary Obstruction: Treatment by Means of Placement of a Newly Designed Y-Shaped Branched Covered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Jong Hyouk, E-mail: xell1015@naver.com; Jung, Gyoo-Sik, E-mail: gsjung@medimail.co.kr; Park, Jung Gu [Kosin University College of Medicine, Departments of Diagnostic Radiology (Korea, Republic of); Kang, Byung Chul [Ewha Womans University College of Medicine, Departments of Radiology, Mokdong Hospital (Korea, Republic of); Shin, Dong-Hoon [Kosin University College of Medicine, Departments of General Surgery (Korea, Republic of); Yun, Byung Chul; Lee, Sang Uk [Kosin University College of Medicine, Departments of Internal Medicine (Korea, Republic of)

    2016-04-15

    PurposeTo evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction.MethodsFrom June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent percutaneous placement of a Y-shaped branched covered stent for palliative treatment. Technical and clinical success, complications, cumulative patient survival, and stent patency were evaluated.ResultsStent placement was technically successful in all patients. All patients showed adequate biliary drainage on the follow-up cholangiogram. Mean serum bilirubin level (10.9 mg/dl) decreased significantly 1 week (5.7 mg/dl) and 1 month (2.6 mg/dl) after stent placement (p < 0.01). Complications associated with the procedure included hemobilia (n = 3) and biloma (n = 1). During the mean follow-up period of 225 (range 12–820) days, nine patients (26.5 %) developed stent occlusion caused by tumor overgrowth (n = 8) and sludge (n = 1). Two of them underwent coaxial placement of a second stent with good results. The median survival time was 281 days and median primary stent patency was 337 days. There were no significant differences in the patient survival and stent patency rates in relation to age, sex, or Bismuth type.ConclusionPercutaneous placement of the Y-shaped branched covered stent seems to be technically feasible and clinically effective for palliative treatment of malignant hilar biliary obstruction.

  16. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  17. Effects of the temporary placement of a self-expandable metallic stent in benign pyloric stenosis.

    Science.gov (United States)

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-07-01

    The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Twenty-two patients with benign stenosis of the prepylorus, pylorus, and duodenal bulb were enrolled and underwent SEMS placement. We assessed symptom improvement, defined as an increase of at least 1 degree in the gastric-outlet-obstruction scoring system after stent insertion. No major complications were observed during the procedures. After stent placement, early symptom improvement was achieved in 18 of 22 patients (81.8%). During the follow-up period (mean 10.2 months), the stents remained in place successfully for 6 to 8 weeks in seven patients (31.8%). Among the 15 patients (62.5%) with stent migration, seven (46.6%) showed continued symptomatic improvement without recurrence of obstructive symptoms. Despite the symptomatic improvement, temporary SEMS placement is premature as an effective therapeutic tool for benign pyloric stenosis unless a novel stent is developed to prevent migration.

  18. Percutaneous transluminal angioplasty and stent placement for iliofemoral arterial atherosclerotic occlusive disease

    International Nuclear Information System (INIS)

    Zheng Yanbo; Jiang Wenjin; Liu Sheng; Song Xuepeng; Sheng Qirui

    2006-01-01

    Objectives: To assess the safety and efficacy of percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of iliofemoral arterial atherosclerotic occlusive diseases. Methods From April 1999 to August 2004, 13 cases of iliofemoral arterial occlusions were recanalized with contact thrombolytic therapy combined with guide wire mechanical recanalization method, followed by angioplasty and stent placement. A total of 25 self-expanding Wallstents were deployed. All patients were followed up by means of duplex ultrasound, angiography, or both. Results: All 13 cases were successfully recanalized, with technical successful rate of 100%. Available follow-up for all patients from 8 months-5 years (mean 26.2 months) included one patient undergoing again with successful contact thrombolysis because of early thrombosis; another patient with recurrent symptoms at 19 month after operation undertaking surgical bypass because of later reocclusion; all of the rest stents showing patency by the end of the study. Conclusions: Contact thrombolysis combined with guide wire mechanical recanalization for iliofemoral arterial occlusion is safe and effective, whereas PTA and stent placement would have the nearly same efficacy for the disease with mild injury and low restenosis. (authors)

  19. Intravascular ultrasound evaluation of a pseudolesion created by stent placement in the right artery.

    Science.gov (United States)

    Zientek, D M; Rodgers, G P

    1999-10-01

    The creation of a pseudolesion after guidewire placement in tortuous arterial segments is a well recognized phenomenon. Intravascular ultrasound has been useful in assessing deployment of intracoronary stents and equivocal angiographic findings. We present a case in which a pseudolesion was not observed until after placement of an intracoronary stent. Intravascular ultrasound demonstrated no dissection or significant lesion; however, there was focal calcification just distal to the stent providing a substrate for the distorted vessel architecture. The lesion resolved with removal of the guidewire.

  20. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  1. Stent placement for benign colonic stenosis: case report, review of the literature, and animal pilot data.

    Science.gov (United States)

    Geiger, Timothy M; Miedema, Brent W; Tsereteli, Zurab; Sporn, Emanuel; Thaler, Klaus

    2008-10-01

    Permanent metal stent placement for malignant intestinal obstruction has been proven to be efficient. Temporary stents for benign conditions of the colon and rectum are less studied. This is a case study, review of the literature, and observation from an animal model on placement of stents in the colorectum for benign disease. A 55-year-old man presented with recurrent obstructions from a benign stricture of the distal sigmoid colon. After failed balloon dilations, a polyester coated stent was placed. The purpose of the stent was to improve symptoms and avoid surgery. The stent was expelled after 5 days. We conducted a literature review of stents placed for benign colorectal strictures and an animal study to evaluate stent migration. In the literature, there were 53 reports of uncovered metal stents, four covered metal stents, and six polyester stents. Patency rates were 71%, and migration rate was 43%. Migration occurred earlier with polyester stents (mean=8 days) versus covered (32 days) or uncovered metal stents (112 days). Severe complications were seen in 23% of patients. Four 45-kg pigs underwent rectosigmoid transection with a 21-mm anastomosis and endoscopic placement of a Polyflex stent. Two stents were secured with suture. Stents without fixation were expelled within 24 h of surgery. Stents with fixation were expelled between postoperative days 2 and 14. Stents for the treatment of benign colorectal strictures are safe, with comparable patency rates between stent types. Metal stents can cause severe complications. In a pig model, covered polyester stents tend to migrate early even with fixation. Further investigation needs to focus on new stent designs and/or better fixation.

  2. Bleeding after expandable nitinol stent placement in patients with esophageal and upper gastrointestinal obstruction: incidence, management, and predictors.

    Science.gov (United States)

    Oh, Se Jin; Song, Ho-Young; Nam, Deok Ho; Ko, Heung Kyu; Park, Jung-Hoon; Na, Han Kyu; Lee, Jong Jin; Kang, Min Kyoung

    2014-11-01

    Placement of self-expandable nitinol stents is useful for the treatment of esophageal and upper gastrointestinal (GI) obstruction. However, complications such as stent migration, tumor overgrowth, and bleeding occur. Although stent migration and tumor overgrowth are well documented in previous studies, the occurrence of bleeding has not been fully evaluated. To evaluate the incidence, management strategies, and predictors of bleeding after placement of self-expandable nitinol stents in patients with esophageal and upper GI obstruction. We retrospectively reviewed the medical records and results of computed tomography and endoscopy of 1485 consecutive patients with esophageal and upper GI obstructions who underwent fluoroscopically guided stent placement. Bleeding occurred in 25 of 1485 (1.7%) patients 0 to 348 days after stent placement. Early stent-related bleeding occurred in 10 patients (40%) and angiographic embolization was used for 5/10. Late bleeding occurred in 15 patients (60%) and endoscopic hemostasis was used for 7/15. Twenty-two of 25 (88%) patients with bleeding had received prior radiotherapy and/or chemotherapy. Bleeding is a rare complication after placement of expandable nitinol stents in patients with esophageal and upper GI obstruction, but patients with early bleeding may require embolization for control. Care must be exercised on placing stents in patients who have received prior radiotherapy or chemotherapy. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. RESULTS: Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave’s syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. CONCLUSION: The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign

  4. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

    Science.gov (United States)

    van Halsema, Emo E; van Hooft, Jeanin E

    2015-02-16

    To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective studies were identified that analyzed the outcomes of stent placement for refractory benign esophageal strictures. The outcomes of stent placement for benign esophageal leaks, perforations and fistulae were extracted from 20 retrospective studies that were published after the inclusion period of a recent systematic review. Data were pooled and analyzed using descriptive statistics. Fully covered self-expandable metal stents (FC SEMS) (n = 85), biodegradable (BD) stents (n = 77) and self-expandable plastic stents (SEPS) (n = 70) were inserted in 232 patients with refractory benign esophageal strictures. The overall clinical success rate was 24.2% and according to stent type 14.1% for FC SEMS, 32.9% for BD stents and 27.1% for SEPS. Stent migration occurred in 24.6% of cases. The overall complication rate was 31.0%, including major (17.7%) and minor (13.4%) complications. A total of 643 patients were treated with self-expandable stents mainly for postsurgical leaks (64.5%), iatrogenic perforations (19.6%), Boerhaave's syndrome (7.8%) and fistulae (3.7%). FC SEMS and partially covered SEMS were used in the majority of patients. Successful closure of the defect was achieved in 76.8% of patients and according to etiology in 81.4% for postsurgical leaks, 86.0% for perforations and 64.7% for fistulae. The pooled stent migration rate was 16.5%. Stent-related complications occurred in 13.4% of patients, including major (7.8%) and minor (5.5%) complications. The outcomes of stent placement for refractory benign esophageal strictures were poor. However, randomized trials are needed to put this into perspective. The evidence on successful stent placement for benign esophageal leaks, perforations and

  5. Comparison between uncovered and covered self-expandable metal stent placement in malignant duodenal obstruction.

    Science.gov (United States)

    Kim, Ji Won; Jeong, Ji Bong; Lee, Kook Lae; Kim, Byeong Gwan; Ahn, Dong Won; Lee, Jae Kyung; Kim, Su Hwan

    2015-02-07

    To compare the clinical outcomes of uncovered and covered self-expandable metal stent placements in patients with malignant duodenal obstruction. A total of 67 patients were retrospectively enrolled from January 2003 to June 2013. All patients had symptomatic obstruction characterized by nausea, vomiting, reduced oral intake, and weight loss. The exclusion criteria included asymptomatic duodenal obstruction, perforation or peritonitis, concomitant small bowel obstruction, or duodenal obstruction caused by benign strictures. The technical and clinical success rate, complication rate, and stent patency were compared according to the placement of uncovered (n = 38) or covered (n = 29) stents. The technical and clinical success rates did not differ between the uncovered and covered stent groups (100% vs 96.6% and 89.5% vs 82.8%). There were no differences in the overall complication rates between the uncovered and covered stent groups (31.6% vs 41.4%). However, stent migration occurred more frequently with covered than uncovered stents [20.7% (6/29) vs 0% (0/38), P stent patency was longer in uncovered than in covered stents [251 d (95%CI: 149.8 d-352.2 d) vs 139 d (95%CI: 45.5 d-232.5 d), P stent (70 d) and covered stent groups (60 d). Uncovered stents may be preferable in malignant duodenal obstruction because of their greater resistance to stent migration and longer stent patency than covered stents.

  6. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  7. Endovascular treatment for arterial injuries of skull base

    International Nuclear Information System (INIS)

    Li Tianxiao; Bai Weixing; Zai Suiting; Wang Ziliang; Xue Jiangyu

    2008-01-01

    Objective: To explore the role of endovascular techniques in treatment for arterial injuries of skull base. Methods: A total of 53 consecutive cases suffered from skull base arterial injuries were enrolled in our hospital from Oct 2004 to May 2007, including 44 male and 9 female cases with average age of 23.3 years. Thirty-nine cases presented with pulsatile exophthalmos and intracranial vascular murmur, cerchnus and dysphagia in another 9, epistaxis in the remaining 5 cases. Diagnosis of 39 carotid cavernous fistulae (CCF)and 14 carotid pseudoaneurysm were performed by angiography (DSA). Alternative endovascular procedures were performed depending on lesions characteristics and follow-up was done by telephone and outpatient work up. Results: Procedures were performed involving 56 carotid arteries in all 53 cases including 34 CCF with embolization of detachable balloon(33 cases), 3 with balloon and coils, and 3 by stent-graft placement. 8 carotid pseudoaneurysms were cured by parent artery occlusion with balloon, 2 experienced endovascular isolation with balloon and coils, and 4 with stent-graft. Follow-up for mean 9.5 months (range from 2 to 25 months) revealed that the chief symptoms of 45 cases (85%) were relieved within 6 months after the procedure but ocular movement and visual disorder remained in 8 cases (15%)till 12 months. Six pseudoaneurysms and 3 residual leak were found in reexamination, of which 2 cases underwent intervention again 2 and 3 months later due to dural arterial-venous fistula in cavernous sinus, respectively. Conclusions: Endovascular treatment is safe and effective therapeutic option with minimal invasion for skull base arterial injuries. Detachable balloon embolization is the first choice for CCF and carotid pseudoaneurysm. Spring coil packing and stent-graft implantation should be in alternation as combination for special cases. (authors)

  8. Metallic Zinc Exhibits Optimal Biocompatibility for Bioabsorbable Endovascular Stents

    Science.gov (United States)

    Bowen, Patrick K.; Guillory, Roger J.; Shearier, Emily R.; Seitz, Jan-Marten; Drelich, Jaroslaw; Bocks, Martin; Zhao, Feng; Goldman, Jeremy

    2015-01-01

    Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells. PMID:26249616

  9. Comparison of the occlusion of experiemntal craniojugular saccular aneurysms with covered stents

    International Nuclear Information System (INIS)

    Zhang Haixia; Li Minghua; Cheng Yingsheng; Fang Chun; Li Min

    2006-01-01

    Objective: To assess the effectiveness and biocompatibility of balloon-expanding, stainless steel stents covered with biomembrane (BM-SSS) and polyurethane membrane (PUM-SSS) in the treatment of experimental saccular aneurysms in a canine model and to observe the ablation of aneurysm with preservation of the parent vessel. Methods: Sixteen healthy mongrel canines were included in our study. 26 of 29 successful experimental aneurysms were treated with covered stents, another 3 were untreated to serve as controls. Altogether there were fourteen BM-SSS and twelve PUM-SSS were placed endovascularly in the common carotid arteries covering the orifice of the aneurysms. Control angiography was performed immediately after the procedure and after 2 weeks, 4 weeks and 12 weeks. According to grouping time, each aneurysm together with stented arteries was removed with animals alive for histopathological examination. Enumeration data was analyzed by Fisher's Exact Test using SPSS 10.0. Results: Before stent placement, angiography of the common carotid arteries showed round, saccular side-wall aneurysms and complex pattern of flow. Immediately after stent placement the aneurysmal pouches were no longer visible and the stented common carotid arteries remained widely patent. All controlled aneurysms and common carotid arteries have been patent and unchanged for 1 year. 13 of 14 stented common carotid arteries with BM-SSS and 3 of 12 with PUM-SSS remained widely patent. The complete patency rate of BM-SSS and PUM-SSS was significantly different (P=0.0008). Histological analysis indicated that all treated aneurysmal pouches were almost filled with thrombus, as well as with fibrotic reactive scar tissue. Stent wires were found to be located deep within the vessel wall and encased by an extension of the tunica intima. The endothelium of the two groups was already mature at 12 weeks, and various degree of degenerate cells were seen under the transmission electron microscopy. Conclusion

  10. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

    International Nuclear Information System (INIS)

    Rimon, Uri; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Galili, Yair; Schneiderman, Jacob; Morag, Benyamina

    2004-01-01

    Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn

  11. Clinical evaluation of the efficacy and influencing factors for stent placement in treating benign and malignant esophageal stenosis

    International Nuclear Information System (INIS)

    Guo Xiaohua; He Jianrong; Lin Kaiqin; Jin Honglai; Li Maoquan; Zhang Qing

    2003-01-01

    Objective: To evaluate clinical effectiveness and influence factors in the treatment of benign and malignant esophageal stenosis by placing esophageal stent. Methods: A series of this research comprised of 29 cases with esophageal cancer, 10 cardiac carcinoma, 5 cardiac achalasia, 6 benign esophageal stricture after operation. The lengths of lesion ranged from 2 to 14 cm in length with mean of 7.3 cm. Fistula were found among malignant esophageal stenosis in 6 cases. According to the dysphagia scores, 12 cases were designated at I grade, 31 with II, and 14 with III. 46 cases of malignancy were undertaken radiation therapy combined with transcatheter arterial chemotherapy from 15 to 30 days after stent placement. Results: 62 stents were placed in 57 cases (52 domestic stents, 10 Boston ultraflex), including 4 cases with 2 stents being once placed, 1 case with second time stent placement because of restenosis 4 month later. All stents were placed successfully without serious complications, such as esophageal perforation, massive hemorrhage. 5 cases of cardiac achalasia and 6 cases of benign esophageal stricture are still alive now. The survival rates of 6, 12, 24 and 36 months in 46 malignant cases, were 67.4%(31/46), 43.5%(20/46), 26.1%(12/46), and 19.6(9/46) respectively. Dysphagia were relieved significantly from 7 to 15 days after stent placement. Conclusions: Esophageal stent placement combined with radiation therapy and transcatheter arterial chemotherapy could improve patient life qualities and survival rates significantly in malignant stricture. The effects on benign esophageal stricture by stent placement are comparable with that of surgical treatment

  12. Endovascular Treatment of Phlegmasia Cerulea Dolens with Impending Venous Gangrene: Manual Aspiration Thrombectomy as the First-Line Thrombus Removal Method

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Ozkan, Ugur; Demirturk, Orhan S.; Gur, Serkan

    2011-01-01

    Purpose: Our purpose was to report the outcome of endovascular treatment with manual aspiration thrombectomy as the first-line thromboablative method for phlegmasia cerulea dolens. Methods: Between October 2006 and May 2010, seven consecutive patients (5 women, 2 men; age range, 31–80 years) with the diagnosis of phlegmasia cerulea dolens secondary to acute iliofemoral deep venous thrombosis had endovascular treatment with manual aspiration thrombectomy. Catheter-directed thrombolysis and stent placement were used as adjunctive procedures. Phlegmasia was left-sided in five and right-sided in two patients. Results: All patients had associated great saphenous vein thrombosis in addition to iliofemoral deep vein thrombosis (DVT). Aspiration thrombectomy completely removed the thrombus from the popliteal vein to the inferior vena cava (IVC) in all cases. Three patients with May-Thurner syndrome had stent placement in the left common iliac vein. Two patients had early recurrences. Repeated aspiration thrombectomy was unsuccessful in one patient. There were no complications related to the procedure. One patient who had been successfully treated died of sepsis and another patient who had unsuccessful repeated interventions had below-the-knee amputation. Overall, the clinical success and survival rates of patients in this study were 86%. On follow-up, three patients with successful treatment were asymptomatic with no deep venous insufficiency. One of these patients died during the 4-month follow-up period. Two patients had mild ankle swelling with deep venous insufficiency. Conclusions: Manual aspiration thrombectomy with adjunctive use of catheter-directed thrombolysis and stent placement is an effective endovascular treatment method with high clinical success and survival rates for phlegmasia cerulean dolens.

  13. Endovascular repair as a sole treatment in multiple aneurysms in patient with SLE

    International Nuclear Information System (INIS)

    Dineva, S.; Al-Amin, M.; Demetriou, S.; Tsetis, D.

    2013-01-01

    Full text: Introduction: Most aneurysms are local manifestations of systemic disease. For patients over 65 years the incidence of aneurysm of the abdominal aorta (AAA) is approximately 5-6% in men and 1-2 % for women. The presence of both the AAA and aneurysms in other location is even rarer, and this percentage is likely increase further in patients with systemic lupus erythematosus (SLE). What you will learn: We present a rare clinical case of endovascular treatment of multifocal aneurysm including post catheterization pseudoaneurysm. The patient is a 73 years old woman with a history of SLE and age-related comorbidity. Originally an endovascular treatment of aneurysms of the abdominal aorta and right common iliac artery was used. Two years later a successfully endovascular treatment of aneurysm of the right renal artery was conducted, which however is complicated by the formation of a pseudoaneurysm in access through the left femoral artery. The late one is again treated endovascular by placement of a covered stent after failure of percutaneous injection of 1000 UI thrombin. Discussion: Adult patients with a long history of SLE are unsuitable candidates for surgical treatment of aneurysmal disease, especially in its multifocal form. In our case we have taken multistep successful endovascular procedures, including technically hard placing of the stent at the site of the right renal aneurysms, and post catheterization pseudoaneurysm. Conclusion: Multifocal aneurysmal vascular changes due to macroangiopathia in SLE can be treated alone by endovascular means in multi-stages procedures

  14. Evolution of patency rates of self-expandable bare metal stents for endovascular treatment of femoro-popliteal arterial occlusive disease: Does stent design matter?

    Science.gov (United States)

    Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus

    2017-09-01

    To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.

  15. Supera self-expanding stents for endovascular treatment of femoropopliteal disease: a review of the clinical evidence

    Directory of Open Access Journals (Sweden)

    Bishu K

    2015-07-01

    Full Text Available Kalkidan Bishu,1,2 Ehrin J Armstrong1,21Division of Cardiology, University of Colorado, Aurora, 2Denver VA Medical Center, Denver, CO, USAAbstract: Femoropopliteal lesions account for a significant proportion of endovascular interventions for peripheral artery disease in patients with disabling claudication or chronic limb ischemia. The femoropopliteal artery crosses two joint structures (hip and knee joints and courses through the muscular adductor canal in the thigh, which places the artery at increased biomechanical stress. There is a critical need for stent platforms with a reduced risk of stent fracture while maintaining patency during long-term follow-up. The Supera peripheral stent system has a braided nickel–titanium alloy stent designed to withstand the unique stressors along the course of the femoropopliteal artery. This design may be associated with improved patency in association with reduced stent fracture rates on short- and medium-term follow-up. Further studies, including randomized controlled studies, comparing the Supera interwoven nickel–titanium alloy stent system with other stent platforms and angioplasty alone are needed.Keywords: peripheral artery disease, femoropopliteal atherosclerosis, SUPERA interwoven nitinol stent, stent fracture

  16. Ultrathin endoscope-assisted self-expandable metallic stent placement following initial unsuccessful attempt in malignant upper gastrointestinal obstruction.

    Science.gov (United States)

    Park, Se Woo; Lee, Hyuk; Park, Jun Chul; Shin, Sung Kwan; Lee, Sang Kil; Lee, Yong Chan

    2014-03-01

    Conventional endoscopy for self-expandable metallic stent (SEMS) placement may be technically limited in long and tortuous strictures. Therefore, we analyzed the feasibility, safety and usefulness of ultrathin endoscopy (UTE)-guided SEMS placement. This study involved 24 patients with upper gastrointestinal obstruction and unsuccessful initial attempts to place SEMS using conventional endoscopy. After completely passing a UTE across the stricture, the UTE was withdrawn, leaving a guidewire placed via the working channel. Through-the-scope SEMS placement was done using a conventional endoscope inserted along the guidewire. The primary endpoints were assessed by technical/clinical success and stent patency duration. Stents were successfully placed at target locations in all but one case with a long tortuous stricture, with 95.8% (23/24) technical success. One week after stent placement, mean gastricoutlet obstruction score improved significantly from baseline (1.74 ± 0.62 and 0.33 ± 0.48, respectively; P Stent migration, restenosis, and fracture occurred in four (17.4%), six (26.1%), and one (4.3%) of 23 stents, respectively. Median stent patency duration was 79 days. Mean stent patency was significantly longer in patients who received palliative chemotherapy than in those who did not (122.9 ± 11.0 and 38.3 ± 4.6, respectively; P < 0.001). UTE guidance SEMS delivery can be a feasible and safe rescue treatment method for malignant upper gastrointestinal obstruction in cases of failed attempts to place SEMS using conventional endoscopy. Our result warrants a further study to define the efficacy of this method in difficult SEMS placement cases. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.

  17. Self-expandable metallic stent placement for patients with inoperable esophageal carcinoma. Investigation of the influence of prior radiotherapy and chemotherapy

    International Nuclear Information System (INIS)

    Ihara, Yuko; Murayama, Sadayuki; Toita, Takafumi; Utsunomiya, Takashi; Nagata, Osamu; Akamine, Tamaki; Ogawa, Kazuhiko; Adachi, Genki; Tanigawa, Noboru

    2006-01-01

    The aim of this study was to evaluate the efficacy and complications of self-expandable metallic stent placement for patients with inoperable esophageal carcinoma after radiotherapy and/or chemotherapy. We obtained data from 19 patients with advanced or recurrent esophageal carcinoma between 1996 and 2000. In all patients, a self-expandable metallic stent was placed under fluoroscopic guidance. Dysphagia before and after stent placement was graded. Complications after stent placement were also evaluated. Data were compared between patients with and without prior radiotherapy and/or chemotherapy. The procedure was technically successful in all but one patient. The dysphagia grade improved in all patients. No life-threatening complications occurred. The other major complications such as mediastinitis occurred in two patients, and pneumonia and funnel phenomenon occurred in one patient each. These patients had a history of radiotherapy and/or chemotherapy prior to stent placement. Eight of the twelve patients with prior radiotherapy and/or chemotherapy compared with one of seven patients without prior therapy had persistent chest pain, which was a statistically significant difference (P<0.05). Placement of self-expandable metallic stents was effective for patients with advanced or recurrent esophageal carcinoma. However, prior irradiation and/or chemotherapy increased the risk of persistent chest pain after stent placement. (author)

  18. [Findings from Total Colonoscopy in Obstructive Colorectal Cancer Patients Who Underwent Stent Placement as a Bridge to Surgery(BTS)].

    Science.gov (United States)

    Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki

    2017-11-01

    We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.

  19. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  20. Immediate, short‐, and long‐term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome

    Science.gov (United States)

    Raske, Matthew; Berent, Allyson C.; McDougall, Renee; Lamb, Kenneth

    2018-01-01

    Background Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Objectives Identify immediate post‐stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate‐, short‐, and long‐term periods, and evaluate inter‐observer reliability of radiographic measurements. Animals Fifty client‐owned dogs. Methods Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post‐stent placement radiographic follow‐up times. Radiographs were used to obtain pre‐stent tracheal measurements and post‐stent placement measurements. Results Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Ultimate mean follow‐up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra‐thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long‐term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short‐, or long‐term periods. Good inter‐observer agreement of radiographic measurements was found among observers of variable experience level. Conclusions and Clinical Importance Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. PMID:29460368

  1. Silicone Stent Placement for Primary Tracheal Amyloidosis Accompanied by Cartilage Destruction

    OpenAIRE

    Ryu, Duck Hyun; Eom, Jung Seop; Jeong, Ho Jung; Kim, Jung Hoon; Lee, Ji Eun; Jun, Ji Eun; Song, Dae Hyun; Han, Joungho; Kim, Hojoong

    2014-01-01

    Primary tracheal amyloidosis (PTA) can lead to airway obstructions, and patients with severe PTA should undergo bronchoscopic interventions in order to maintain airway patency. Focal airway involvements with amyloidosis can only be treated with mechanical dilatation. However, the PTA with diffused airway involvements and concomitant cartilage destructions requires stent placement. Limited information regarding the usefulness of silicone stents in patients with PTA has been released. Therefore...

  2. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  3. Management of Endovascular Aortic Aneurysm Complications via Retrograde Catheterization Through the Distal Stent-Graft Landing Zone.

    Science.gov (United States)

    Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao

    2017-08-01

    A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.

  4. Endovascular revascularization for aortoiliac atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Aggarwal V

    2016-03-01

    Full Text Available Vikas Aggarwal,1 Stephen W Waldo,2,3 Ehrin J Armstrong2,3 1Prairie Heart Institute, St John's Hospital, Springfield, IL, 2Section of Cardiology, Denver Veterans Affairs Medical Center, 3Section of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Atherosclerotic iliac artery disease is increasingly being treated with endovascular techniques. A number of new stent technologies can be utilized with high long-term patency, including self-expanding stents, balloon-expandable stents, and covered stents, but comparative data on these stent types and in more complex lesions are lacking. This article provides a review of currently available iliac stent technologies, as well as complex procedural aspects of iliac artery interventions, including approaches to the treatment of iliac bifurcation disease, long segment occlusions, choice of stent type, and treatment of iliac artery in-stent restenosis. Keywords: peripheral artery disease, iliac artery, balloon expandable stent, self expanding stent, covered stent, claudication, endovascular

  5. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  6. Immediate, short-, and long-term changes in tracheal stent diameter, length, and positioning after placement in dogs with tracheal collapse syndrome.

    Science.gov (United States)

    Raske, Matthew; Weisse, Chick; Berent, Allyson C; McDougall, Renee; Lamb, Kenneth

    2018-03-01

    Intraluminal tracheal stenting is a minimally invasive procedure shown to have variable degrees of success in managing clinical signs associated with tracheal collapse syndrome (CTCS) in dogs. Identify immediate post-stent changes in tracheal diameter, determine the extent of stent migration, and stent shortening after stent placement in the immediate-, short-, and long-term periods, and evaluate inter-observer reliability of radiographic measurements. Fifty client-owned dogs. Retrospective study in which medical records were reviewed in dogs with CTCS treated with an intraluminal tracheal stent. Data collected included signalment, location, and type of collapse, stent diameter and length, and post-stent placement radiographic follow-up times. Radiographs were used to obtain pre-stent tracheal measurements and post-stent placement measurements. Immediate mean percentage change was 5.14%, 5.49%, and 21.64% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Ultimate mean follow-up time was 446 days, with mean percentage change of 2.55%, 15.09%, and 8.65% for cervical, thoracic inlet, and intra-thoracic tracheal diameters, respectively. Initial mean stent length was 26.72% higher than nominal length and ultimate long-term tracheal mean stent shortening was only 9.90%. No significant stent migration was identified in the immediate, short-, or long-term periods. Good inter-observer agreement of radiographic measurements was found among observers of variable experience level. Use of an intraluminal tracheal stent for CTCS is associated with minimal stent shortening with no clinically relevant stent migration after fluoroscopic placement. Precise stent sizing and placement techniques likely play important roles in avoiding these reported complications. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Placement of retrievable self-expandable metallic stents with barbs into patients with obstructive prostate cancer.

    Science.gov (United States)

    Song, Ho-Young; Kim, Choung Soo; Jeong, In Gab; Yoo, Dalsan; Kim, Jin Hyoung; Nam, Deok Ho; Bae, Jae-Ik; Park, Jung-Hoon

    2013-03-01

    To evaluate the technical feasibility and clinical effectiveness of retrievable self-expandable metallic stents with barbs in patients with obstructive prostate cancer. Retrievable self-expandable metallic stents with eight barbs each were inserted into eight consecutive patients with obstructive prostate cancer. Patient ages ranged from 55 to 76 years (mean, 69 years). All eight patients had previously received hormone therapy, and three had undergone palliative transurethral prostatectomy. Stents were removed using a 21-F stent removal set if they caused complications. Stent placement was technically successful and well tolerated in all patients. One had severe incontinence, which improved spontaneously, and two had gross haematuria, which disappeared spontaneously within 4 days. Peak urine flow rates and post-void residual urine volumes 1 month after stent placement were 5.6-10.2 ml/s (mean, 8.3 ml/s), and 5-45 ml (mean, 27 ml), respectively. During a mean follow-up of 192 days (range, 39-632 days), one patient required stent removal after 232 days because of stone formation within the stent. No further intervention was required because the mass improved after stent removal. These preliminary results suggest that retrievable stents with eight barbs are both feasible to place and effective in patients with obstructive prostate cancer.

  8. Percutaneous placement of self-expandable metallic stents in patients with obstructive janudice secondary to metastalic gastric cancer after gastrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Seo, In Ho; Yu, Jung Rim; Mok, Young Jae; Oh, Joo Hyeong [Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of); Kwon, Se Hwan [Dept. of Radiology, Kyung Hee University Medical Center, Seoul (Korea, Republic of); Kim, Sam Soo [Dept. of Radiology, Kangwon National University College of Medicine, Chuncheon (Korea, Republic of); Kim, Seung Kwon [Division of Interventional Radiology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis (United States)

    2013-10-15

    To evaluate the outcomes of patients undergoing percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy. Fifty patients (mean age, 62.4 years; range, 27-86 years) who underwent percutaneous placements of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy were included. The technical success rate, clinical success rate, complication rate, stent patency, patient survival and factors associated with stent patency were being evaluated. The median interval between the gastrectomy and stent placement was 23.1 months (range, 3.9-94.6 months). The 50 patients received a total of 65 stents without any major procedure-related complications. Technical success was achieved in all patients. The mean total serum bilirubin level, which had been 7.19 mg/dL ± 6.8 before stent insertion, decreased to 4.58 mg/dL ± 5.4 during the first week of follow-up (p < 0.001). Clinical success was achieved in 42 patients (84%). Percutaneous transhepatic biliary drainage catheters were removed from 45 patients (90%). Infectious complications were noted in two patients (4%), and stent malfunction occurred in seven patients (14%). The median stent patency was 233 ± 99 days, and the median patient survival was 179 ± 83 days. Total serum bilirubin level after stenting was an independent factor for stent patency (p = 0.009). Percutaneous transhepatic placement of a biliary stent for obstructive jaundice secondary to metastatic gastric cancer after gastrectomy is a technically feasible and clinically effective palliative procedure.

  9. Stroke prevention by endovascular treatment of carotid and vertebral artery dissections.

    Science.gov (United States)

    Moon, Karam; Albuquerque, Felipe C; Cole, Tyler; Gross, Bradley A; McDougall, Cameron G

    2017-10-01

    Endovascular intervention for cervical carotid artery dissection (CAD) and vertebral artery dissection (VAD) may be indicated in specific circumstances. To review our institutional experience with endovascular treatment of cervical dissections over the past 20 years to examine indications for treatment, interventional methods, and outcomes. Retrospective review of a prospectively maintained database to identify patients with extracranial dissection who underwent endovascular intervention between January 1996 and January 2016. Demographic data and details of procedures, outcomes, and complications were extracted. Of 116 patients [93 CAD, 23 VAD; mean age 44.9 years (range 5-76 years)], 104 underwent stent placement; 11, coil occlusion of the parent artery; and 1, stenting with contralateral vessel occlusion. The cohorts were well matched for age, sex, dissection etiology, and admission and follow-up modified Rankin Scale (mRS) scores. Patients with CAD had significantly more stent placements (p<0.001), failure of medical therapy (p=0.004), and interventions for enlarging pseudoaneurysms (p=0.01) or thromboembolic events (p=0.004). Patients with VAD had significantly more interventions for traumatic occlusion with recanalization (p<0.001). Dissections were spontaneous (n=67), traumatic (n=36), or iatrogenic (n=13). Traumatic dissections in patients with CAD were associated with poor admission mRS scores (p=0.01). Six of 67 (9.0%) patients with spontaneous dissection reported recent chiropractic manipulation. Mean follow-up was 3.5 years (range 1-146 months). Permanent morbidity/mortality was 3.4%, including two deaths. Over a follow-up period of 364 patient-years, 1 stroke occurred (0.27% per year). At last follow-up, 41 previously disabled patients [CAD, 31/93 (33.3%); VAD, 10/23 (43.5%)] were no longer disabled; no patient reported worsened disability. Patients with CAD and VAD differ significantly in presentation, indications for treatment, and treatment

  10. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Hans, F.J.; Thiex, R.; Gilsbach, J.M.; Krings, T.; Moeller-Hartmann, W.; Dreeskamp, H.; Stein, K.P.; Meetz, A.; Thron, A.; Pfeffer, J.; Scherer, K.; Brunn, A.

    2003-01-01

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  11. Self-Expandable Stent Placement in Infrapopliteal Arteries After Unsuccessful Angioplasty Failure: One-Year Follow-up

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Smirova, S.; Koznar, B.; Novotny, J.; Kovac, J.; Lastovickova, J.; Skibova, J.

    2008-01-01

    The purpose of this prospective study was to evaluate whether stent placement in infrapopliteal arteries is helpful in failed percutaneous transluminal angioplasty (PTA). Infrapopliteal PTA was performed in 70 arteries of 66 patients with chronic critical lower limb ischemia. The group comprised 55 males and 11 females, with an average age of 63.4 (range, 42-82) years. Diabetes mellitus was present in 92.4% of patients. Only the palpable anterior tibial and posterior tibial arteries were evaluated. Stents (Xpert stent; Abbot Vascular, Redwood City, CA, USA) were placed in 16 arteries where PTA was not successful (the failure was defined as residual stenosis >30% after PTA). In 54 arteries simple PTA was performed and was technically successful. Twenty-four nondilated arteries with no significant stenosis served as a comparison group. The 12-month patency rate was evaluated according to a combination of palpation and Doppler ultrasound. In all cases stent placement restored the flow in the artery immediately after unsuccessful PTA. Twelve-month follow-up showed a patency rate of 82% in the PTA group, 78% in the stent group, and 69% in the comparison group. We conclude that stent placement in the case of unsuccessful infrapopliteal PTA changed technical failure to success and restored flow in the dilated artery. At 12-month follow-up the patency rate of infrapopliteal arteries stented for PTA failure did not differ significantly either from nonstented arteries with an optimal PTA result or from a comparison group of nonintervened arteries.

  12. Endovascular Treatment of a Bleeding Secondary Aorto-Enteric Fistula. A Case Report with 1-Year Follow-up

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vasdekis, Spyros; Kostopanagiotou, Georgia; Danias, Nikolaos; Alexopoulou, Efthymia; Petropoulou, Konstantina; Gouliamos, Athanasios; Perros, Georgios

    2007-01-01

    We report a patient with life-threatening gastrointestinal bleeding caused by a secondary aorto-enteric fistula. Because the patient had several comorbid conditions, we successfully stopped the bleeding by endovascular placement of a bifurcated aortic stent-graft. The patient developed periaortic infection 4 months later, but he was managed with antibiotics. The patient is well 1 year after the procedure

  13. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  14. Stent placement for tracheal stenosis in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Takagi, Keigo; Hata, Yoshinobu; Sasamoto, Shuichi; Takahashi, Shoji; Sato, Fumitomo; Tamaki, Kazuyoshi; Goto, Hidenori; Yuasa, Rena

    2011-01-01

    Tracheal invasion including tracheal bifurcation due to esophageal cancer can sometimes cause serious complications of the airway, but such cases sometimes improve quickly following chemoradiation treatment. The absolute indications for stent replacement in the airway for this disorder and the optimal choice of stent are herein discussed. Between 1992 and 2010, 28 patients with airway stenosis, including 7 patients with esophago-tracheal fistula, were treated by placement of various stents; namely, 12 patients received Dumon stents, 3 patients had Dynamic stents, 10 patients were given Ultraflex stents, while 3 other patients were treated without the use of stents. Severe dyspnea in the supine position was observed, which mainly originated from invasion to the membranous portion of the trachea. Airway patency was maintained after stent replacement, although the median survival time of such cases was only 4 months. Three patients with severe dyspnea who could lie in a supine position recovered after undergoing chemoradiation treatment without stent replacement. No cases of stent removal were observed after chemoradiation treatment. Chemoradiation treatment for esophageal cancer was found to be effective for the management of airway disturbances, and thus the absolute indications for stent replacement are restricted to patients who cannot lie in a supine position due to severe impairment of ventilation during radiation therapy, as well as patients presenting with tracheobroncho-esophageal fistula. Concerning stent selection, a metal stent should be the first choice for tracheal stenosis due to its ease of insertion, because there is no substantial difference between silicone and metal stents regarding the treatment of tracheal stenosis. However, it is important to note that a silicone Y stent is useful for the treatment of tracheal bifurcation. (author)

  15. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  16. Percutaneous pancreatic stent placement for postoperative pancreaticojejunostomy stenosis: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Koo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Yoon, Chang Jin [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-09-15

    Stenosis of the pancreatico-enteric anastomosis is one of the major complications of pancreaticoduodenectomy (PD). Endoscopic stent placement, has limited success rate as a nonsurgical treatment due to altered gastrointestinal anatomy. Percutaneous treatment is rarely attempted due to the technical difficulty in accessing the pancreatic duct. We reported a case of pancreaticojejunostomy stenosis after PD, in which a pancreatic stent was successfully placed using a rendezvous technique with a dual percutaneous approach.

  17. Percutaneous pancreatic stent placement for postoperative pancreaticojejunostomy stenosis: A case report

    International Nuclear Information System (INIS)

    Yang, Seung Koo; Yoon, Chang Jin

    2016-01-01

    Stenosis of the pancreatico-enteric anastomosis is one of the major complications of pancreaticoduodenectomy (PD). Endoscopic stent placement, has limited success rate as a nonsurgical treatment due to altered gastrointestinal anatomy. Percutaneous treatment is rarely attempted due to the technical difficulty in accessing the pancreatic duct. We reported a case of pancreaticojejunostomy stenosis after PD, in which a pancreatic stent was successfully placed using a rendezvous technique with a dual percutaneous approach

  18. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  19. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  20. Self-expandable metallic stent placement plus laparoscopy for acute malignant colorectal obstruction.

    Science.gov (United States)

    Zhou, Jia-Min; Yao, Li-Qing; Xu, Jian-Min; Xu, Mei-Dong; Zhou, Ping-Hong; Chen, Wei-Feng; Shi, Qiang; Ren, Zhong; Chen, Tao; Zhong, Yun-Shi

    2013-09-07

    To investigate the clinical advantages of the stent-laparoscopy approach to treat colorectal cancer (CRC) patients with acute colorectal obstruction (ACO). From April 2008 to April 2012, surgery-related parameters, complications, overall survival (OS), and disease-free survival (DFS) of 74 consecutive patients with left-sided CRC presented with ACO who underwent self-expandable metallic stent (SEMS) placement followed by one-stage open (n = 58) or laparoscopic resection (n = 16) were evaluated retrospectively. The stent-laparoscopy group was also compared with a control group of 96 CRC patients who underwent regular laparoscopy without ACO between January 2010 and December 2011 to explore whether SEMS placement influenced the laparoscopic procedure or reduced long-term survival by influencing CRC oncological characteristics. The characteristics of patients among these groups were comparable. The rate of conversion to open surgery was 12.5% in the stent-laparoscopy group. Bowel function recovery and postoperative hospital stay were significantly shorter (3.3 ± 0.9 d vs 4.2 ± 1.5 d and 6.7 ± 1.1 d vs 9.5 ± 6.7 d, P = 0.016 and P = 0.005), and surgical time was significantly longer (152.1 ± 44.4 min vs 127.4 ± 38.4 min, P = 0.045) in the stent-laparoscopy group than in the stent-open group. Surgery-related complications and the rate of admission to the intensive care unit were lower in the stent-laparoscopy group. There were no significant differences in the interval between stenting and surgery, intraoperative blood loss, OS, and DFS between the two stent groups. Compared with those in the stent-laparoscopy group, all surgery-related parameters, complications, OS, and DFS in the control group were comparable. The stent-laparoscopy approach is a feasible, rapid, and minimally invasive option for patients with ACO caused by left-sided CRC and can achieve a favorable long-term prognosis.

  1. Neointimal responses 3 months after 32P β-emitting stent placement

    International Nuclear Information System (INIS)

    Farb, Andrew; Tang, Anita L.; Shroff, Sweta; Sweet, William; Virmani, Renu

    2000-01-01

    Purpose: Studies have shown a potential benefit of brachytherapy in preventing restenosis. However, the effects of intravascular radiation on arterial healing have not been well-established. The purpose of this study was to explore the histologic changes following placement of β-emitting radioactive stents in arteries focusing on intimal responses and endothelialization. Methods and Materials: 3.0-mm β-emitting 32 P stents (6-μCi and 24-μCi) were placed in rabbit iliac arteries with nonradioactive stents serving as controls. Animals were euthanized at 3 months and histologic assessment, morphometry, and analysis of endothelialization were performed. Results: The lumen areas of 24-μCi stents (4.24 ± 0.22 mm 2 , p 2 , p 2 ). The mean lumen percent stenosis was 11.4 ± 3.0% in the 24-μCi stents (p 32 P β-emitting stents reduce neointimal growth, but healing is incomplete with poor endothelialization at 3 months. Longer-term studies with complete arterial healing are needed to determine whether there is sustained neointimal inhibition by stent-delivered brachytherapy

  2. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    Science.gov (United States)

    2012-01-01

    Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS) and plastic stents (PS).We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS), functional success (FS), early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III). Results The initial stent insertion was successful in 450 (93.8%) patients. TS was achieved in 204 (88.3%) patients treated with PS and in 246 (98.8%) patients palliated with SEMS (p stent patency in weeks (w) were as follows: 20 w in patients palliated with PS and 27 w in patients treated with SEMS (p stent patency. Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients. PMID:22873816

  3. Endoscopic stenting for hilar cholangiocarcinoma: efficacy of unilateral and bilateral placement of plastic and metal stents in a retrospective review of 480 patients

    Directory of Open Access Journals (Sweden)

    Liberato Manuel José

    2012-08-01

    Full Text Available Abstract Background Endoscopic biliary drainage of hilar cholangiocarcinoma is controversial with respect to the optimal types of stents and the extent of drainage. This study evaluated endoscopic palliation in patients with hilar cholangiocarcinoma using self-expandable metallic stents (SEMS and plastic stents (PS.We also compared unilateral and bilateral stent placement according to the Bismuth classification. Methods Data on 480 patients receiving endoscopic biliary drainage for hilar cholangiocarcinoma between September 1995 and December 2010 were retrospectively reviewed to evaluate the following outcome parameters: technical success (TS, functional success (FS, early and late complications, stent patency and survival. Patients were followed from stent insertion until death or stent occlusion. Patients were divided into 3 groups according to the Bismuth classification (Group 1, type I; Group 2, type II; Group 3, type > III. Results The initial stent insertion was successful in 450 (93.8% patients. TS was achieved in 204 (88.3% patients treated with PS and in 246 (98.8% patients palliated with SEMS (p P P  Conclusions SEMS insertion for the palliation of hilar cholangiocarcinoma offers higher technical and clinical success rates in the ITT analysis as well as lower complication rates and a superior cumulative stent patency when compared with PS placement in all Bismuth classifications. The cumulative patency of bilateral SEMS or PS stents was significantly higher than that of unilateral SEMS or PS stents, with lower occlusion rates in Bismuth II patients.

  4. Temporary placement of covered retrievable expandable nitinol stents with barbs in high-risk surgical patients with benign prostatic hyperplasia: work in progress.

    Science.gov (United States)

    Kim, Choung-Soo; Song, Ho-Young; Jeong, In Gab; Yeo, Hyun Jin; Kim, Eun-Young; Park, Jung-Hoon; Yoon, Chang Jin; Paick, Sung Hyun; Park, Sang Woo; Bae, Jae-Ik; Won, Je Hwan

    2011-10-01

    To report the use of a newly constructed, covered, retrievable, expandable nitinol stent with barbs to overcome the problem of stent migration associated with conventional covered prostatic expandable stents and to evaluate prospectively the technical feasibility and clinical effectiveness of the stents in patients with benign prostatic hyperplasia (BPH). A covered retrievable expandable nitinol stent with four barbs was placed with use of an 18-F stent delivery system in seven consecutive patients with symptomatic BPH who had high operative risks. Age range of patients was 62-83 years (mean 74 years). In cases in which the stent migrated, it was replaced with a stent with eight barbs. The stents were routinely removed 4 months after placement using a 21-F stent removal set. Stent placement was technically successful and well tolerated in six of the seven patients. The remaining patient needed a second stent placement after removal of the first stent. The stent with four barbs migrated into the urinary bladder in four patients (57%); three of these patients received a second stent with eight barbs with good results, and the fourth patient did not need further treatment because his symptoms improved. Routine removal of the stent 4 months after placement was performed in three of the seven patients with good results. Retrievable stents with eight barbs seem to overcome the problem of stent migration associated with conventional prostatic expandable stents. Preliminary results suggest that stents with barbs are both feasible and effective in patients with BPH. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  5. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Prabhudesai, V.; Mitra, K.; West, D. J.; Dean, M. R. E.

    2003-01-01

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome

  6. A Case of Pseudoaneurysm of the Internal Carotid Artery Following Endoscopic Endonasal Pituitary Surgery: Endovascular Treatment with Flow-Diverting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali Karadag

    2017-10-01

    Full Text Available Internal carotid artery (ICA pseudoaneurysm is a rare complication of endoscopic endonasal surgery occurring in 0.4–1.1% of cases. Pseudoaneurysms can subsequently result in other complications, such as subarachnoid hemorrhage, epistaxis, and caroticocavernous fistula with resultant death or permanent neurologic deficit. In this case, we illustrate endovascular treatment with a flow-diverting stent for an ICA pseudoaneurysm after endoscopic endonasal surgery for a pituitary adenoma in a 56-year-old male. Surgery was complicated by excessive intraoperative bleeding and emergent CT angiography confirmed an iatrogenic pseudoaneurysm on the anteromedial surface of the ICA. The pseudoaneurysm was treated endovascularly with flow-diverting stent implantation only. Follow-up CT angiography after three months demonstrated occlusion of the pseudoaneurysm.

  7. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  8. Endovascular Treatment of Dialysis Access-Induced Hand Ischemia Using a Flared Stent-Graft.

    Science.gov (United States)

    Png, Chien Yi M; Beckerman, William E; Faries, Peter L; Finlay, David J

    2017-10-01

    To report an investigation of a purely endovascular procedure to address access-induced hand ischemia in dialysis patients. Two dialysis patients presented with stage III steal syndrome consisting of severe pain and numbness in their fingers. Preoperative fistulograms distal to the anastomosis showed alternating antegrade and retrograde flow. Under ultrasound guidance, the fistula was accessed and a 4-F micropuncture sheath placed. An angled guidewire was then advanced proximally into the brachial artery. A 6-F short sheath with marker was placed followed by a 4-F straight guide catheter inserted into the proximal brachial artery. A 9-F Flair endovascular stent-graft was advanced over a 0.035-inch stiff angled Glidewire into the fistula just distal to the arterial anastomosis and deployed. Postoperatively, pain and numbness resolved in both patients immediately. Postoperative fistulograms documented antegrade flow. Access flow velocity readings decreased significantly and pulse oximetry readings increased significantly in both patients, who were followed for >6 months with no reported complications. These 2 cases suggest that this endovascular approach to access-induced hand ischemia may be a viable alternative to open/hybrid surgery.

  9. Outcome of ureteral stent placement for treatment of benign ureteral obstruction in dogs: 44 cases (2010-2013).

    Science.gov (United States)

    Pavia, Philippa R; Berent, Allyson C; Weisse, Chick W; Neiman, Dana; Lamb, Kenneth; Bagley, Demetrius

    2018-03-15

    OBJECTIVE To describe the technique and short- and long-term outcomes for dogs undergoing double-pigtail ureteral stent placement for treatment of benign ureteral obstruction. DESIGN Retrospective case series. ANIMALS 44 dogs (57 ureters). PROCEDURES Medical records of dogs that underwent ureteral stenting for treatment of benign ureteral obstruction between 2010 and 2013 were reviewed. Signal-ment, history, pertinent diagnostic imaging results, endourologic and post-procedural details, duration of hospitalization, complications, and outcome (short term, 7 to 30 days; long term, > 30 days) were recorded. Ureteral stent placement was performed endoscopically, surgically, or both, with fluoroscopic guidance. RESULTS 57 ureters (44 dogs) underwent stenting because of obstructive ureterolithiasis (n = 48 [84%]), stricture (5 [9%]), or both (4 [7%]). Endoscopic or surgical techniques were successful for stent placement in 45 of 55 and 12 of 12 ureters (34/42 and 10/10 dogs), respectively. Median hospitalization time was 1 day. Median creatinine concentration was 2 mg/dL prior to stenting and 1.3 mg/dL 3 months after the procedure. Urinary tract infections were present in 26 of 44 (59%) dogs prior to stenting and in 11 of 43 dogs (26%) after stenting. One of the 44 (2%) dogs died after undergoing stenting, but the cause of death was not related to the procedure. Median follow-up time was 1,158 days (range, 3 to > 1,555 days), with 30 of 44 dogs alive at the time of last follow-up. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ureteral stenting may be a viable option for first-line treatment of dogs with benign ureteral obstruction. However, patients should be monitored for urinary tract infection following stenting.

  10. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  11. Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Rajan, Dheeraj K.; Saluja, Jasdeep S.

    2007-01-01

    Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm. The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is

  12. Stent placement for palliation of cor triatriatum dexter in a dog with suspected patent foramen ovale.

    Science.gov (United States)

    Barncord, Kristin; Stauthammer, Christopher; Moen, Sean L; Hanson, Melissa; Gruenstein, Daniel H

    2016-03-01

    An 11 month old spayed, female dog presented with exercise intolerance and cyanosis upon exertion. Echocardiography revealed an imperforate cor triatriatum dexter with mild tricuspid valve dysplasia, an underfilled right ventricle and significant right to left shunting across a presumptive patent foramen ovale. Balloon dilation of the abnormal atrial membrane was initially successful in creating a communication between the right atrial chambers, but stenosis of the original perforation and persistent clinical signs prompted a second intervention. A balloon expandable biliary stent was placed across the abnormal partition, improving caudal venous return to the right ventricle and reducing the right to left shunt. Three months after stent placement, resting oxygen saturation had normalized. Six months after stent placement, exercise tolerance had improved and exertional cyanosis had resolved. Long term follow up will be necessary to assess for remodeling of the right ventricle with improved venous return. Stent placement can be considered as a palliative treatment option for cor triatriatum dexter, especially for stenosis post-balloon dilation. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Iliac Artery Stent Placement Relieves Claudication in Patients with Iliac and Superficial Femoral Artery Lesions

    International Nuclear Information System (INIS)

    Ichihashi, Shigeo; Higashiura, Wataru; Itoh, Hirofumi; Sakaguchi, Shoji; Kichikawa, Kimihiko

    2013-01-01

    Purpose. To evaluate the efficacy of iliac artery stent placement for relief of claudication in patients with both iliac and superficial femoral artery (SFA) lesions. Methods. Stent placement for only iliac artery occlusive disease was performed in 94 limbs (74 patients) with both iliac and SFA occlusive disease on the same limb. All procedures were performed because intermittent claudication did not improve after continuation of antiplatelet medication therapy and home-based exercise for 3 months. Rutherford classification was 2 in 20 limbs and 3 in 74 limbs. Patients with critical limb ischemia were excluded. Median duration of follow-up was 40 months. Primary patency rates of the iliac stent, clinical improvement rates, and risk factors for requiring additional SFA procedures were evaluated. Results. Primary patency rates of the iliac stent at 1, 3, 5, and 7 years were 97, 93, 79, and 79 %, respectively. The initial clinical improvement rate was 87 %. Continued clinical improvement rates at 1, 3, 5, and 7 years were 87, 81, 69, and 66 %, respectively. SFA Trans-Atlantic Inter-Society Consensus (TASC) II C/D lesion was a significant risk factor for requiring additional SFA procedures. Conclusion. Intermittent claudication was relieved by iliac stent placement in most patients with both iliac and SFA lesions. Thus, the indications for treatment of the SFA intended for claudicants should be evaluated after treatment of the iliac lesion.

  14. Metallic stent placement for the management of acute colorectal obstruction caused by colorectal carcinomas: its effect on scheduled surgery

    International Nuclear Information System (INIS)

    Cao Yan; Liu Bingyan; Mao Aiwu; Yin Xiang; Gao Zhongdu

    2011-01-01

    Objective: To prospectively evaluate the safety and clinical efficacy of a newly designed self-expandable metallic stent (SEMS) placement in the treatment of patients with acute malignant colorectal obstruction due to colorectal carcinomas. Methods: During the period from April 2001 to October 2007, a total of 52 patients with acute malignant colorectal obstruction were treated with stent placement by using a new designed SEMS, which was employed as a preoperative transit means. All the patients were followed up and the relevant data, including technical success rate, clinical efficacy, complications and overall survival rate, were documented. The results were analyzed. Results: Stent placement was successfully carried out in all patients except for two patients who showed complete colorectal obstruction. No procedure-related complications occurred. Technical success rate was 96% (50/52). Two days after the treatment, the relief rate of colorectal obstruction was 98% (49/50). Postoperative complications included stent migration (n=4), anal pain (n=2) and stool impaction (n=1). The stool impaction seen in one patient was successfully removed away with endoscopic manipulation two days after stent placement. An elective one-stage surgical procedure was performed in all 50 patients who successfully received a SEMS placement within a mean interval of (8±2) days (ranged 4-11 days) after stent placement. Mean follow-up time was (36±12) months with a range of (3-70) months. All patients remained alive at the time of this report. Conclusion: The newly designed SEMS placement used as a preoperative transit means is a safe and effective intervention for colonic decompression in patients with acute malignant colorectal obstruction due to colorectal carcinomas. It can reliably ensure most of patients with colorectal carcinomas to successfully accomplish an elective surgery. (authors)

  15. Impact of Carcinomatosis on Clinical Outcomes after Self-Expandable Metallic Stent Placement for Malignant Gastric Outlet Obstruction.

    Directory of Open Access Journals (Sweden)

    Ji Eun Lee

    Full Text Available It is still unclear whether the peritoneal carcinomatosis had a negative effect on the clinical outcomes of patients who underwent self-expandable metallic stent (SEMS placement for malignant gastric outlet obstruction (GOO. Although carcinomatosis may be associated with the development of multifocal gastrointestinal (GI tract obstruction or decreased bowel movement, previous studies investigated the occurrence of stent failure only and thus had limitation in evaluating clinical outcomes of patients with carcinomatosis.Between 2009 and 2013, 155 patients (88 patients without carcinomatosis and 67 patients with carcinomatosis underwent endoscopic SEMS placement for malignant GOO. Factors affecting clinical success and obstructive symptom-free survival (time period between SEMS placement and the recurrence of obstructive symptoms due to multifocal GI tract obstruction or decreased bowel movement as well as stent failure were assessed.Patients with carcinomatosis showed higher Eastern Cooperative Oncology Group (ECOG scale than those without carcinomatosis. Clinical success rates were 88.1% in patients with carcinomatosis and 97.7% in patients without carcinomatosis. In multivariate analysis, only ECOG scale was identified as an independent predictor of clinical success. During follow-up period, patients with carcinomatosis showed significantly shorter obstructive symptom-free survival than those without carcinomatosis. In multivariate analysis, the presence of carcinomatosis, chemotherapy or radiation therapy after SEMS placement, and obstruction site were identified as independent predictors of obstructive symptom-free survival. For patient without carcinomatosis, stent failure accounted for the recurrence of obstructive symptoms in 84.6% of cases. For patients with carcinomatosis, multifocal GI tract obstruction or decreased bowel movement accounted for 37.9% of cases with obstructive symptom recurrence and stent failure accounted for 44.8% of

  16. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  17. Poly-lactic-acid coating of endovascular stents: preliminary results in canine experimental av-fistulae

    Energy Technology Data Exchange (ETDEWEB)

    Schellhammer, F. [Freiburg Univ. (Germany). Dept. of Neuroradiology; Koeln Univ. (Germany). Dept. of Radiology; Berlis, A. [Bonn Univ. (Germany). Dept. of Radiology; Bloss, H.G. [Freiburg Univ. (Germany). Dept. of Neurosurgery; Pagenstecher, A. [Freiburg Univ. (Germany). Dept. of Neuropathology; Schumacher, M. [Freiburg Univ. (Germany). Dept. of Neuroradiology

    2001-02-01

    Poly-Lactic-Acid (PLA) was evaluated for coating of vascular endoprotheses in the treatment of experimental arterio-venous-fistulae (AVF). Bilateral carotid-external jugular AVF were created in 5 adult dogs. 7 PLA coated nitinol stents were placed via a transfemoral approach covering 5 AVF. The contralateral AVF remained untreated. Angiography was performed immediately after stent placement, at weeks 1 and 3 and at months 3, 6 and 9. All grafts were removed and underwent histologic examination. In 2 cases the occlusion of the AVF was successful, while misplacement occurred in 3 cases. Occlusion of the parent vessel was disclosed in 3 cases. Histologic examination revealed a mild inflammatory reaction with the presence of macrophages. There was no foreign-body reaction or fragmentation of the arterial vessel wall. PLA, which is a well-known biodegradable material, showed a good mid-term biocompatibility. Elastic mismatch of the non-elastic coating and the self-expandable nitinol stent caused misplacement. Frequent vessel-occlusions were probably due to PLA-filaments fraying into the vessel lumen. Using a different textile structure PLA might be a material suitable for coating endovascular stents. (orig.) [German] In der vorliegenden Arbeit wurden mit Poly-Laktid ummantelte Gefaessprothesen in der Behandlung von experimentell angelegten arterio-venoesen Gefaesskurzschluessen getestet. Gefaesskurzschlussverbindungen der Halsarterien mit der parallel dazu verlaufenden, tiefen Halsvene wurden in 5 Hunden operativ angelegt. 7 mit Poly-Laktid ummantelte Gefaessprothesen aus Nitinol wurden in jeweils eine Halsarterie implantiert, so dass die Gefaesskurzschlussverbindungen vollstaendig ueberdeckt war. Die gegenueberliegende Seite verblieb als Kontrolle unbehandelt. Radiologische Gefaessdarstellungen erfolgten unmittelbar nach Implantation der Gefaessprothese, nach 1 und 3 Wochen sowie nach 3, 6 und 9 Monaten. Alle Prothesen wurden operativ entfernt und feingeweblich

  18. Utility of MR cholangiography for follow-up examination after metallic stent placement in the bile duct

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Hi; Yang, Dal Mo; Kim Hak Soo; Cho, Seung Whi; Kim, Hyung Sik; Jin Wook; Hwang, Hee Young [Gachon Medical College Gil Medical Center, Incheon (Korea, Republic of)

    2002-09-01

    To evaluate the efficacy of MR cholangiography for follow-up examination after metallic stent placement in the bile duct. Between December 1999 and June 2000, 15 patients with biliary obstruction in whom metallic biliary stents had been placed underwent MR cholangiography during follow-up examination. The causes of obstruction were hilar cholangiocarcinoma (n=6), common bile duct cancer (n=5), gall bladder cancer (n=1) and pancreatic cancer (m=3). The types of self-expandable metallic stent employed were the nitinol stent (n=2), the endocoil nitinol stent (n=3), the ultraflexed diamond stent (n=5), and the wallstent (n=5). Using MR cholangiography, we measured the diameter of that part of the biliary stent which showed high signal intensity, assigning one point if this was less than one third of the stent diameter, two points of between one third and two thirds, and three points if more than two thirds. We decided that a higher score indicated fewer artifacts. The score was 1.7-3 (mean, 2.3) points for the endocoil nitinol stent, 1.7-2.3 (mean, 2) for the nitinol stent, and 1-3 (mean, 1.7) for the ultraflex diamond stent. In most cases, two thirds of the stent diameter was observed. For the wallstent, the score was 1-1.7 (mean, 1.3) points and the inner portion of the stent was almost invisible. MR cholangiography is not useful for follow-up examination after the placement of wallstents and three other types of nitinol stent in the bile duct.

  19. Placement of a Newly Designed Y-Configured Bilateral Self-Expanding Metallic Stent for Hilar Biliary Obstruction: A Pilot Study.

    Science.gov (United States)

    Jiao, Dechao; Huang, Kai; Zhu, Ming; Wu, Gang; Ren, Jianzhuang; Wang, Yanli; Han, Xinwei

    2017-01-01

    Whether unilateral or bilateral drainage should be performed for malignant hilar biliary obstruction remains a matter of debate. Although a Y-stent with a central wide-open mesh facilitates bilateral stent placement, it has its own limitations. This study aims to evaluate the feasibility and efficacy of a newly designed Y-configured bilateral self-expanding metallic stent (SEMS) for the treatment of hilar biliary obstruction. In this retrospective study, 14 consecutive patients with unresectable malignant hilar biliary obstruction (Bismuth type II or higher), who underwent placement of a newly designed Y-configured bilateral SEMS for hilar biliary obstruction from April 2013 to March 2015, were included into this study. Data on technical success, clinical success, stent patency, complications and patient survival were collected. Technical and clinical success was 100 and 92.9 %, respectively. Mean serum bilirubin level was significantly decreased 1 month after stent placement (P hilar biliary obstruction using port docking deployment.

  20. Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

    Science.gov (United States)

    Liu, Jian; Jing, Linkai; Wang, Chao; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-11-01

    Endovascular treatment of paraclinoid aneurysms is preferred in clinical practice. Flow alterations caused by stents and coils may affect treatment outcome. To assess hemodynamic changes following stent-assisted coil embolization (SACE) in subtotally embolized paraclinoid aneurysms with residual necks that were predisposed to recanalization. We studied 27 paraclinoid aneurysms (seven recanalized and 20 stable) treated with coils and Enterprise stents. Computational fluid dynamic simulations were performed on patient-specific aneurysm geometries using virtual stenting and porous media technology. After stent placement in 27 cases, aneurysm flow velocity decreased significantly, the reduction gradually increasing from the neck plane (11.9%), to the residual neck (12.3%), to the aneurysm dome (16.3%). Subsequent coil embolization was performed after stent placement and the hemodynamic factors decreased further and significantly at all aneurysm regions except the neck plane. In a comparison of recanalized and stable cases, univariate analysis showed no significant differences in any parameter before treatment. After stent-assisted coiling, only the reduction in area-averaged velocity at the neck plane differed significantly between recanalized (8.1%) and stable cases (20.5%) (p=0.016). Aneurysm flow velocity can be significantly decreased by stent placement and coil embolization. However, hemodynamics at the aneurysm neck plane is less sensitive to coils. Significant reduction in flow velocity at the neck plane may be an important factor in preventing recanalization of paraclinoid aneurysms after subtotal SACE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Endovascular graft exclusion in treating thoracic aortic dissection: a report of 25 cases

    International Nuclear Information System (INIS)

    Chen Wei; Yang Jianyong; Zhuang Wenquan; Guo Wenbo; Li Heping; Zhong Lizhen; Huang Qiuping

    2003-01-01

    Objective: To evaluate the usefulness and efficacy of endovascular graft exclusion (EVGE) in treating thoracic aortic dissection (TAD). Methods: Twenty-five cases of TAD, including 24 cases of Standford B and 1 case of A, were treated by EVGE. The clinical outcome and morphological changes of the lesions were analyzed during a 2-20 months' follow-up. Results: Procedures were technically successful in all 25 cases, while a total of 28 stent-grafts were deployed (3 cases with 2 stent-grafts in each). Complete disappearance of the false lumen or remarkable decrease of the endoleak was noted on the angiograms after stent placement. No severe procedure-related complication was observed, and thrombosis of the false lumen was noted during the follow-up. Conclusion: EVGE is effective and reliable in treating TAD, especially for patients with sub-acute or chronic courses

  2. Prophylactic IVC Filter Placement during Endovascular Treatment of Deep Venous Thrombosis of the Lower Extremities

    International Nuclear Information System (INIS)

    Roh, Byung Suk; Cho, Han Il; Lee, Yeum Sik; Bang, Dong Ho; Park, Seong Hoon; Lee, Young Hwan

    2009-01-01

    To evaluate the efficacy of an IVC filter implantation in the prevent of a pulmonary embolism (PE) during endovascular treatment for a deep venous thrombosis (DVT) of the lower extremities. We implanted IVC filters in 43 patients (22 females, 21 males, average age: 63 years) with DVT and who had undergone treatments including thrombolysis, aspiration and mechanical thrombectomy, as well as stent placement. We evaluated the incidence of PE by capturing the thrombus within the IVC filters, as well as the amount of captured thrombus. New developing PE or aggravating of PE in patients with existing PE was avoided in all patients. No thrombus was evident in the IVC filter of 19 (44%) of the patients, whereas any thrombus was captured in 24 (56%) of the patients. Small amounts of thrombus were captured in 10 patients, whereas large amounts of thrombus were captured in 14 patents within the IVC filter. We performed a retrieval of the IVC filters in 17 patients within an average period of 15.3 days (range 6-45 days). The captured incidence of migrated thrombus in the IVC filters was high in 56% of cases. As a result, PE was effectively prevented by IVC filters during the interventional treatment of DVT in the lower extremities

  3. Prophylactic IVC Filter Placement during Endovascular Treatment of Deep Venous Thrombosis of the Lower Extremities

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Byung Suk; Cho, Han Il; Lee, Yeum Sik; Bang, Dong Ho; Park, Seong Hoon; Lee, Young Hwan [Wonkwang University Hospital, Iksan (Korea, Republic of)

    2009-09-15

    To evaluate the efficacy of an IVC filter implantation in the prevent of a pulmonary embolism (PE) during endovascular treatment for a deep venous thrombosis (DVT) of the lower extremities. We implanted IVC filters in 43 patients (22 females, 21 males, average age: 63 years) with DVT and who had undergone treatments including thrombolysis, aspiration and mechanical thrombectomy, as well as stent placement. We evaluated the incidence of PE by capturing the thrombus within the IVC filters, as well as the amount of captured thrombus. New developing PE or aggravating of PE in patients with existing PE was avoided in all patients. No thrombus was evident in the IVC filter of 19 (44%) of the patients, whereas any thrombus was captured in 24 (56%) of the patients. Small amounts of thrombus were captured in 10 patients, whereas large amounts of thrombus were captured in 14 patents within the IVC filter. We performed a retrieval of the IVC filters in 17 patients within an average period of 15.3 days (range 6-45 days). The captured incidence of migrated thrombus in the IVC filters was high in 56% of cases. As a result, PE was effectively prevented by IVC filters during the interventional treatment of DVT in the lower extremities.

  4. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive......, probably caused by ischemic conditions developed before stent-decompression of the colon was revealed during the operation. The patient died in the postoperative course. We discuss the observation of patients treated with self-expanding metal stents based on the selection-strategy used to allocate patients...

  5. Endoscopic placement of double-J ureteric stents in children as a treatment for primary obstructive megaureter

    Directory of Open Access Journals (Sweden)

    Carroll Daniel

    2010-01-01

    Full Text Available Aim: To determine the efficacy and potential complications of double-J ureteric stents in the treatment of persistent or progressive primary obstructive megaureter in pediatric patients within our institution. Materials and Methods: A retrospective case-note review of all patients with double-J ureteric stents, between 1997 and 2004, was performed. In all, 38 stents were inserted in 31 patients aged between 2 months and 15 years of age. Complications and results of follow-up investigations and the need for follow-up investigations were recorded. Patients were followed up clinically and radiologically for a minimum of 2 years following stent insertion. Results: Endoscopic placement of double-J ureteric stents in childhood is straightforward and complications are uncommon (8/38 insertions. In non-resolving or progressive primary non-refluxing megaureter, double-J ureteric stenting alone is effective with resolution of primary non-refluxing megaureter in 66% of cases (25/38 insertions. Conclusions: Ureteric stenting provides an alternative to early surgery in patients with primary non-refluxing megaureter. The youngest patient in our series was 2 months old at the time of endoscopic ureteric double-J stent insertion. Endoscopic placement of ureteric double-J stents should be considered as a first-line treatment in the management of persistent or progressive non-refluxing megaureter leading to progressive hydronephrosis or pyonephrosis.

  6. Stent type used does not impact complication rate or placement time but can decrease treatment cost for benign and malignant esophageal lesions

    Institute of Scientific and Technical Information of China (English)

    Camille; McGaw[1; Ahmad; Alkaddour[2; Kenneth; J; Vega[3; Juan; Carlos; Munoz[1

    2016-01-01

    AIM: To evaluate if differences exist between selfexpanding esophageal metal stents (SEMS) and selfexpanding esophageal plastic stents (SEPS) when used for benign or malignant esophageal disorders with regard to safety, efficacy, clinical outcomes, placement ease and cost.METHODS: A retrospective analysis was performed to evaluate outcome in patients having SEPS/SEMS placed for malignant or benign esophageal conditions from January 2005 to April 2012. Inclusion criteria was completed SEMS/SEPS placement. Outcomes assessed included technical success of and time required for stent placement, procedure-related complications, need for repeat intervention, hospital stay, mortality and costs.RESULTS: Forty-three patients underwent stent placement for either benign/malignant esophageal disease during the study period. Thirty patients had SEMS (25 male, mean age 59.6 years old) and 13 patients had SEPS (10 male, mean age 61.7 years old). Placement outcome as well as complication rate (SEPS 23.1%, SEMS 25.2%) and in-hospital mortality (SEPS 7.7%, SEMS 6.7%) after placement did not differ between stent types. Migration was the most frequent complication reported occurring equally between types (SEPS 66.7%, SEMS 57.1%). SEPS was less costly than SEMS, decreasing institutional cost by $255/stent. CONCLUSION: SEPS and SEMS have similar outcomes when used for benign or malignant esophageal conditions. However, SEPS use results in decreased costs without impacting care.

  7. Stent type used does not impact complication rate or placement time but can decrease treatment cost for benign and malignant esophageal lesions

    Institute of Scientific and Technical Information of China (English)

    Camille McGaw; Ahmad Alkaddour; Kenneth J Vega; Juan Carlos Munoz

    2016-01-01

    AIM: To evaluate if differences exist between selfexpanding esophageal metal stents(SEMS) and selfexpanding esophageal plastic stents(SEPS) when used for benign or malignant esophageal disorders with regard to safety, efficacy, clinical outcomes, placement ease and cost.METHODS: A retrospective analysis was performed to evaluate outcome in patients having SEPS/SEMS placed for malignant or benign esophageal conditions from January 2005 to April 2012. Inclusion criteria was completed SEMS/SEPS placement. Outcomes assessed included technical success of and time required for stent placement, procedure-related complications, need for repeat intervention, hospital stay, mortality and costs.RESULTS: Forty-three patients underwent stent placement for either benign/malignant esophagealdisease during the study period. Thirty patients had SEMS(25 male, mean age 59.6 years old) and 13 patients had SEPS(10 male, mean age 61.7 years old). Placement outcome as well as complication rate(SEPS 23.1%, SEMS 25.2%) and in-hospital mortality(SEPS 7.7%, SEMS 6.7%) after placement did not differ between stent types. Migration was the most frequent complication reported occurring equally between types(SEPS 66.7%, SEMS 57.1%). SEPS was less costly than SEMS, decreasing institutional cost by $255/stent.CONCLUSION: SEPS and SEMS have similar outcomes when used for benign or malignant esophageal conditions. However, SEPS use results in decreased costs without impacting care.

  8. Preoperative JJ stent placement in ureteric and renal stone treatment: results from the Clinical Research Office of Endourological Society (CROES) ureteroscopy (URS) Global Study.

    Science.gov (United States)

    Assimos, Dean; Crisci, Alfonso; Culkin, Daniel; Xue, Wei; Roelofs, Anita; Duvdevani, Mordechai; Desai, Mahesh; de la Rosette, Jean

    2016-04-01

    To compare outcomes of ureteric and renal stone treatment with ureteroscopy (URS) in patients with or without the placement of a preoperative JJ stent. The Clinical Research Office of the Endourological Society (CROES) URS Global Study collected prospective data for 1 year on consecutive patients with ureteric or renal stones treated with URS at 114 centres around the world. Patients that had had preoperative JJ stent placement were compared with those that did not. Inverse-probability-weighted regression adjustment (IPWRA) was used to examine the effect of preoperative JJ stent placement on the stone-free rate (SFR), length of hospital stay (LOHS), operative duration, and complications (rate and severity). Of 8 189 patients with ureteric stones, there were 978 (11.9%) and 7 133 patients with and without a preoperative JJ stent, respectively. Of the 1 622 patients with renal stones, 590 (36.4%) had preoperative stenting and 1 002 did not. For renal stone treatment, preoperative stent placement increased the SFR and operative time, and there was a borderline significant decrease in intraoperative complications. For ureteric stone treatment, preoperative stent placement was associated with longer operative duration and decreased LOHS, but there was no difference in the SFR and complications. One major limitation of the study was that the reason for JJ stent placement was not identified preoperatively. The placement of a preoperative JJ stent increases SFRs and decreases complications in patients with renal stones but not in those with ureteric stones. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  9. Stent placement with the monorail technique for treatment of mesenteric artery stenosis.

    Science.gov (United States)

    Schaefer, Philipp J; Schaefer, Fritz K W; Hinrichsen, Holger; Jahnke, Thomas; Charalambous, Nikolas; Heller, Martin; Mueller-Huelsbeck, Stefan

    2006-04-01

    To analyze the immediate and midterm success of stenting of mesenteric arteries by a monorail technique in patients with chronic mesenteric ischemia. In this prospective case series, 19 patients (11 male, 8 female; mean age, 62.9 +/- 10.4 y; range, 36-82 y) with 23 symptomatic stenoses of mesenteric arteries were treated with stent placement by a monorail technique in a radiologic intervention center over a period of 4.5 years. Clinical examinations and duplex sonography were used to evaluate the stents' patency and clinical success. Kaplan-Meier graphs were calculated to analyze the patency and freedom-from-symptom rate. Initial technical success rate was 22/23 (96%). Mean follow-up was 17 months (range, 1-58 mo). Primary patency and primary clinical success rates were 82% and 78%, respectively. According to Kaplan-Meier tables, the patency rates were 96%, 87%, 76%, and 61% at 0, 1, 15, and 24 months, respectively, and the freedom-from-symptom rates were 95%, 90%, 72%, and 54% at 0, 1, 24, and 30 months, respectively. No peri-interventional complications occurred. Two patients died of cardiac failure in the hospital within 30 days after intervention; deaths were not related to the intervention. Stent placement by a monorail technique in mesenteric arteries is an effective and safe treatment for symptomatic stenoses in patients with chronic mesenteric ischemia after a mean follow-up of 17 months.

  10. The operative cooperation and nursing in performing airway stent placement under DSA guidance for treating airway stenosis

    International Nuclear Information System (INIS)

    Yan Baojun; Wu Gang; Han Xinwei; Wang Nan; Shi Jin; Si Wenfeng; Wang Kai; Su Ning; Liu Jia; Hai Dandan

    2011-01-01

    Objective: To discuss the key points of the nursing care for effectively performing airway stent placement under DSA monitoring for airway stenosis. Methods: Corresponding nursing care measures were carried out for 118 patients with airway stenosis who were treated with airway stent placement. Results: The symptom of dyspnea was markedly relieved after stent implantation in all 118 patients with airway stenosis. Conclusion: To strengthen the preoperative psychological nursing and operative posture training, to make close postoperative watch on vital signs, to adopt some prevention measures for possible complications and to give necessary medical advises at the time of discharge are very helpful for patient's recovery after the surgery. (authors)

  11. Percutaneous transhepatic stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms.

    Science.gov (United States)

    Kim, Kyung Rae; Ko, Gi-Young; Sung, Kyu-Bo; Yoon, Hyun-Ki

    2011-04-01

    The purpose of this study was to evaluate the efficacy and safety of stent placement in the management of portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. From September 1995 to April 2007, percutaneous transhepatic portal venous stent placement was attempted in 19 patients with postoperative portal venous stenosis. Portal venous stenosis was a complication of surgery in 11 patients and caused by tumor recurrence in eight patients. The clinical manifestations were ascites, hematochezia, melena, esophageal varices, and abnormal liver function. Stents were placed in the stenotic or occluded lesions after percutaneous transhepatic portography. Technical and clinical success, stent patency, and complications were evaluated. Stent placement was successful in 18 patients (technical success rate, 95%). Clinical manifestations improved in 16 patients (clinical success rate, 84%). The mean patency period among the 18 patients with technical success was 21.3 ± 23.2 months. The mean patency period of the benign stenosis group (30.1 ± 25.6 months) was longer than that of the tumor recurrence group (7.3 ± 7.7 months), and the difference was statistically significant (p = 0.038). There were two cases of a minor complication (transient fever) and three cases of major complications (septicemia, liver abscess, and acute portal venous thrombosis). Percutaneous transhepatic stent placement can be safe and effective in relieving portal venous stenosis after curative surgery for pancreatic and biliary neoplasms. Patients with benign stenosis had more favorable results than did those with tumor recurrence.

  12. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  13. Temporary metallic stent placement in the treatment of refractory benign esophageal strictures: results and factors associated with outcome in 55 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Hyoung; Kim, Kyung Rae; Shin, Ji Hoon; Lim, Jin-Oh [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Song, Ho-Young [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea)]|[University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology, Seoul (Korea); Choi, Eugene K. [Weill Medical College of Cornell University, New York, NY (United States)

    2009-02-15

    The purpose of this study was to evaluate the effectiveness of temporary metallic stenting in 55 patients with treatment-resistant benign esophageal strictures and to identify factors associated with clinical outcomes. Under fluoroscopic guidance, covered retrievable stents were placed in 55 patients with benign esophageal strictures and were removed with retrieval hook 1 week to 6 months after placement. Stent placement was successful in all patients, and the mean dysphagia score was reduced from 2.8 to 1.3 (p<0.001). The most common complications were tissue hyperproliferation (31%), severe pain (24%), and stent migration (25%). During follow-up (mean: 38 months), recurrence of the stricture necessitating balloon dilation was seen in 38 (69%) of 55 patients. Maintained patency rates after temporary stenting at 1, 3, and 6 months and 1, 2, and 4 years were 58%, 43%, 38%, 33%, 26%, and 21%, respectively. In multivariate analysis, length (p=0.003) of the stricture was the only significant factor associated with maintained patency after temporary stenting. In conclusion, temporary metallic stenting for refractory benign esophageal strictures may be effective during the period of stent placement, but is disadvantaged by the high recurrence rates after stent removal, particularly in patients with a long length of stricture (>7cm). (orig.)

  14. Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Hyeran; Choi, Sun Young, E-mail: medmath@hanmail.net [School of Medicine Ewha Womans University, Department of Radiology and Medical Research Institute (Korea, Republic of); Kim, Kyung Ah [St. Vincent’s Hospital, The Catholic University of Korea, Department of Radiology (Korea, Republic of); Ko, Soo Bin [College of Arts and Science Case Western Reserve University, Department of Biology (United States)

    2016-09-15

    PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting

  15. Safety and Efficacy of Percutaneous Biliary Covered Stent Placement in Patients with Malignant Biliary Hilar Obstruction; Correlation with Liver Function

    International Nuclear Information System (INIS)

    Hyun, Hyeran; Choi, Sun Young; Kim, Kyung Ah; Ko, Soo Bin

    2016-01-01

    PurposeTo estimate the safety and efficacy of percutaneous ePTFE-covered biliary stent placement and the relationship between underlying liver function and stent patency in patients with malignant hilar obstruction.Materials and MethodsFrom March 2012 to June 2015, 41 patients [22 females, 19 males; mean age 69.8 (range 34–94) years] with malignant biliary obstruction underwent percutaneous biliary stent placement (31 patients with unilateral, 10 patients with bilateral side-by-side). Cumulative patient survival and stent patency rate curves were derived using the Kaplan–Meier method. A Cox model was used to explore the relationship between liver function and patient survival, and also biliary stent patency. Pearson correlation coefficient was used to analyze the relationship between patient survival and stent patency.ResultsTechnical success rate was 100 % and clinical success rate was 95 %. During follow-up, four complications occurred (two bilomas and two cases of acute cholecystitis) and were treated successfully with percutaneous drainage. No other complication occurred. Mean serum bilirubin level was 11.34 ± 7.35 mg/dL before drainage and 5.00 ± 4.83 mg/dL 2 weeks after stent placement. The median patent survival duration was 147 days (95 % CI, 69.6–224.4 days). The median stent patency duration was 101 days (95 % CI, 70.0–132.0 days). The cumulative stent patency rates at 1, 3, 6, and 12 months were 97, 57.6, 30.3, and 17.0 %, respectively. Child–Pugh score was correlated significantly with patient survival (P = 0.011) and stent patency (P = 0.007). MELD score was correlated significantly with stent patency (P = 0.044). There was a correlation between patient survival and stent patency (r = 0.778, P < 0.001).ConclusionPercutaneous placement of ePTFE-covered biliary stent was a safe and an effective method for malignant biliary obstruction. Underlying liver function seemed to be one of the important factors affecting

  16. Delayed ischemic cecal perforation despite optimal decompression after placement of a self-expanding metal stent: report of a case

    DEFF Research Database (Denmark)

    Knop, Filip Krag; Pilsgaard, Bo; Meisner, Søren

    2004-01-01

    Endoscopic deployment of self-expanding metal stents offers an alternative to surgical intervention in rectocolonic obstructions. Reported clinical failures in the literature are all related to the site of stent placement. We report a case of serious intra-abdominal disease after technically...... and clinically successful stent deployment: a potentially dangerous situation of which the surgeon should be aware. A previously healthy 72-year-old female was referred to our department with symptoms of an obstructing colorectal tumor. Successful stent placement resulted in resolution of the obstructive...... condition. Three days after stent deployment, x-ray examinations revealed a small-bowel obstruction and emergency surgery was performed. Intraoperative findings demonstrated a segment of ileum fixated to the tumor in the small pelvis, resulting in the obstructive condition. Furthermore, a cecal perforation...

  17. Technique, Complication, and Long-Term Outcome for Endovascular Treatment of Iliac Artery Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri

    2010-01-01

    The aim of this study was to report technical details, procedure-related complications, and results of endovascular treatment in chronic iliac artery occlusion. Between 2001 and 2008, endovascular treatments of 127 chronic iliac artery occlusions in 118 patients (8 women and 110 men; mean age, 59 years) were retrospectively reviewed. The study was based on Ad Hoc Committee on Reporting Standards (Society for Vascular Surgery/International Society for Cardiovascular Surgery Standards). All occlusions were treated with stent placement with or without preliminary balloon angioplasty. Kaplan-Meier estimators were used to determine patency rates. Univariate and multivariate analyses were performed to determine variables affecting successful recanalization, major complications, early stent thrombosis (≤30 days), and primary and secondary patency rates. Initial technical success was achieved in 117 (92%) procedures. Successful recanalization was obtained by antegrade approach in 69 of 77 (90%) procedures and by retrograde approach in 52 of 105 (50%) procedures (p < 0.001). Complications were encountered in 28 (24%) patients [minor in 7 patients (6%) and major in 22 patients (19%)]. One death occurred in the operative period secondary to iliac artery rupture. Early stent thrombosis was seen in eight (7%) patients. Presence of critical limb ischemia (p = 0.03), subintimal recanalization (p = 0.03), and major complication (p = 0.02) were the independent predictors of early stent thrombosis on multivariate analysis. Primary and secondary patency rates at 5 years were 63 and 93%, respectively. Presence of critical limb ischemia, TASC type C iliac lesions, combined occlusions of both common and external iliac arteries, and major complications were associated with decreased patency rates on univariate analysis, whereas these factors were not independent predictors of stent patency on multivariate analysis. In conclusion, endovascular treatment of iliac artery occlusion has a

  18. Reocclusion after Self-Expandable Metallic Stent Placement for Relieving Malignant Colorectal Obstruction as a Palliative Treatment

    Directory of Open Access Journals (Sweden)

    Toshikatsu Nitta

    2016-12-01

    Full Text Available Self-expandable metallic stent (SEMS placement has been practiced in several hospitals in Japan, including ours, since January 2012. Here, we report the case of an 82-year-old Japanese man who presented to the hospital with a 1-week history of right hypochondrial pain. Computed tomography (CT findings indicated colorectal cancer. The laboratory findings on admission indicated severe anemia (red blood cell count, 426 × 104/μL; hemoglobin, 7.9 g/dL. We performed SEMS placement because the patient refused to undergo surgery. He did not attend any of the scheduled follow-up visits after SEMS placement. However, a year and a half after the SEMS placement, the patient attended the hospital because of difficulty in passing stool. A plain abdominal CT scan showed bowel reobstruction due to the ascending colon cancer after SEMS placement. We performed an emergency operation, ascending colostomy, on the same day. Colorectal stent placement may be a good treatment option for patients who refuse to undergo conventional therapeutic treatments or in those with unresectable colorectal cancer. Patients should be carefully followed up every few months after SEMS placement because of the risk of reocclusion.

  19. Stent placement under fluoroscopic monitoring and endoscopic direct vision for the treatment of malignant gastroduodenal obstruction: a report of 47 cases

    International Nuclear Information System (INIS)

    Zhang Baoyang; Li Weiping; Jiang Haosheng; Liu Shiyi; Hu Yi

    2009-01-01

    Objective: To discuss the operational technique and clinical effect of metallic stent placement in treating malignant gastroduodenal obstruction. Methods: Metallic stent placement under fluoroscopic monitoring and endoscopic direct vision was performed in 47 patients with malignant gastroduodenal obstruction. A total of 54 metallic stents was used. Results: The procedure was successfully completed in all 47 patients. During the follow-up period, all the patients could take liquid or ordinary diet and were markedly relived of vomiting. The living quality was much improved and no serious complications occurred. Conclusion: Under fluoroscopic monitoring and endoscopic direct vision, stent placement is a safe, effective, technically-simple and time-saving procedure for the treatment of malignant gastroduodenal obstruction with less sufferings to the patient. Therefore, it is definitely worth popularizing this technique in clinical practice. (authors)

  20. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  1. Improvement of quality of life and survival using self-expandable metal stent placement for severe malignant stenosis of the gastric body: a case report

    Directory of Open Access Journals (Sweden)

    Kumagai Hozumi

    2012-09-01

    Full Text Available Abstract Introduction Advanced gastric carcinoma often decreases quality of life because of upper gastrointestinal tract stenosis. Self-expandable metal stents have been thought to be an effective, minimally invasive treatment for stenosis. However, the effectiveness of self-expandable metal stent placement for carcinomatous stenosis of the gastric body and antrum has not been clarified, and there have been few reports of such cases. Case presentation A 74-year-old Japanese woman developed stenosis of the gastric body and antrum caused by advanced gastric cancer during first-line chemotherapy. She developed weight loss and poor nutrition due to inadequate intake. Self-expandable metal stent placement for stenosis of the gastric body and antrum ameliorated her symptoms rapidly and improved her general condition and quality of life. Eight days after self-expandable metal stent placement, second-line chemotherapy could be administered safely. Oral intake and nutritional status were maintained for 117 days after self-expandable metal stent placement, and she died of gastric cancer 176 days after self-expandable metal stent placement and initiation of second-line chemotherapy. Conclusions Self-expandable metal stent placement for carcinomatous stenosis in the gastric body and antrum could be an effective therapeutic strategy for patients with inadequate oral uptake. It may provide rapid improvement of the patient’s general condition and oral intake with minimal complications, comparatively long-term symptom relief, and a survival benefit by allowing second-line chemotherapy.

  2. Delay of surgery after stent placement for resectable malignant colorectal obstruction is associated with higher risk of recurrence

    DEFF Research Database (Denmark)

    Broholm, Malene; Kobborg, Martin; Frostberg, Erik

    2017-01-01

    BACKGROUND: Self-expanding metal stents can be used as bridge to elective surgery for acute malignant colonic obstruction. However, the impact on long-term oncological outcome and the optimal timing of surgery are still unknown. METHOD: This was a retrospective multicenter study performed at four...... colorectal centers. Patients undergoing stent placement as bridge to surgery, between January 2010 and December 2013, were included in the study. Primary outcomes were survival and recurrence rates along with location of the metastases. Additionally, we recorded time from stent placement to elective surgery....... Secondary outcomes were postoperative complication rates. Complications were classified according to the Clavien-Dindo classification score. A logistic regression model was used to describe impact of delayed stent removal on risk of recurrence. RESULTS: This study included 112 patients, with a median follow...

  3. Endovascular Treatment of Chronic Mesenteric Ischemia by Crossing of Two Stents in a Patient with Celiacomesenteric Trunk

    International Nuclear Information System (INIS)

    Khil, Eun Kyung; Lee, Jae Myeong

    2013-01-01

    A 73-year-old woman was presented with a 3-month history of postprandial abdominal pain and weight loss. The patient had an anatomic variant of celiacomesenteric trunk (CMT), with complete occlusion of the superior mesenteric artery (SMA) and significant stenosis of the CMT ostium, resulting in chronic mesenteric ischemia. After several unsuccessful attempts at revascularization of the SMA, celiac artery stenting was performed, followed by SMA stent placement through the previously placed stent mesh into the occlusion site. The patient's symptoms completely resolved after treatment.

  4. Endovascular Treatment of Chronic Mesenteric Ischemia: Report of Five Cases

    International Nuclear Information System (INIS)

    Nyman, Ulf; Ivancev, Krasnodar; Lindh, Mats; Uher, Petr

    1998-01-01

    Purpose: To evaluate the midterm results of percutaneous transluminal angioplasty (PTA) and stent placement in stenotic and occluded mesenteric arteries in five consecutive patients with chronic mesenteric ischemia. Methods: Five patients with 70%-100% obliterations of all mesenteric vessels resulting in chronic mesenteric ischemia (n= 4) and as a prophylactic measure prior to abdominal aortic aneurysm repair (n= 1) underwent PTA of celiac and/or superior mesenteric artery (SMA) stenoses (n= 2), primary stenting of ostial celiac occlusions (n= 2), and secondary stenting of a SMA occlusion (n= 1; recoil after initial PTA). All patients underwent duplex ultrasonography (US) (n= 3) and/or angiography (n= 5) during a median follow-up of 21 months (range 8-42 months). Results: Clinical success was obtained in all five patients. Asymptomatic significant late restenoses (n3) were successfully treated with repeat PTA (n= 2) and stenting of an SMA occlusion (n= 1; celiac stent restenosis). Recurrent pain in one patient was interpreted as secondary to postsurgical abdominal adhesions. Two puncture-site complications occurred requiring local surgical treatment. Conclusions: Endovascular techniques may be attempted prior to surgery in cases of stenotic or short occlusive lesions in patients with chronic mesenteric ischemia. Surgery may still be preferred in patients with long occlusions and a low operative risk

  5. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  6. Hybrid endovascular stent-grafting technique for patent ductus arteriosus in an adult.

    Science.gov (United States)

    Kainuma, S; Kuratani, T; Sawa, Y

    2011-09-01

    A 51-year-old man was referred to our institution for patent ductus arteriosus (PDA) complicated by left ventricular dysfunction and pulmonary hypertension. Surgical closure of a PDA is usually carried out via a small posterior thoracotomy. However, thoracoscopic procedures are probably not appropriate in adults because of the frequency of calcification and the greater risk of rupture while ligating the ductus. To minimize surgical trauma, we used hybrid endovascular stent grafting combined with revascularization of the left subclavian artery, which enabled us to eliminate shunt flow to the pulmonary artery. At 11-month follow-up, the patient was asymptomatic and showed no complications. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Endovascular Treatment of Chronic Mesenteric Ischemia by Crossing of Two Stents in a Patient with Celiacomesenteric Trunk

    Energy Technology Data Exchange (ETDEWEB)

    Khil, Eun Kyung; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2013-06-15

    A 73-year-old woman was presented with a 3-month history of postprandial abdominal pain and weight loss. The patient had an anatomic variant of celiacomesenteric trunk (CMT), with complete occlusion of the superior mesenteric artery (SMA) and significant stenosis of the CMT ostium, resulting in chronic mesenteric ischemia. After several unsuccessful attempts at revascularization of the SMA, celiac artery stenting was performed, followed by SMA stent placement through the previously placed stent mesh into the occlusion site. The patient's symptoms completely resolved after treatment.

  8. Transarterial embolization of an aortoesophageal fistula secondary to placement of a palliative esophageal stent: a case report

    International Nuclear Information System (INIS)

    Cha, Eun Young; Shin, Ji Hoon; Yoon, Hyun Ki; Ko, Gi Young; Sung, Kyu Bo; Kwong, Dong Il; Song, Ho Young

    2007-01-01

    An aortoesophageal fistula is a rare condition caused by descending aortic diseases such as an aneurysm, foreign body ingestion, esophageal malignancy, and ulcers. An aortoesophageal fistula as a complication of esophageal stent placement is extremely rare and only one case had been reported previously worldwide, to the best of our knowledge. We report a case of an aortoesophageal fistula in a 64-year-old man who previously underwent palliative esophageal stent placement due to local tumor recurrence after a total gastrectomy of vanced gastric cancer in the cardia. The fistula was occluded by glue embolization

  9. Stenting of the SFA - indications, techniques,

    International Nuclear Information System (INIS)

    Rieger, J.; Treitl, M.; Reiser, M.; Ruppert, V.

    2006-01-01

    Aggressive risk factor modification, change of eating habits, exercise programs, and forceful antiplatelet therapy are the most important tools for the treatment of PAOD in symptomatic patients suffering from intermittent claudication. There are however no guidelines for revascularization at this stage. Endovascular treatment has been increasingly utilized over the last decade and increasingly displaced vascular surgery. Amongst numerous endovascular techniques beside PTA, stents meanwhile play the most important role due to constant technical progress. Results regarding the rate of restenosis or patency rates still remain worse compared to other vascular beds. This paper gives a review over recent results, currently available stent techniques, and possible indications for the endovascular therapy of an artery, which has turned out to be the biggest ordeal for material and construction of stents. (orig.) [de

  10. Self-expandable metal stent placement versus emergency resection for malignant proximal colon obstructions

    NARCIS (Netherlands)

    Amelung, F.J.; Draaisma, W.A.; Consten, E.C.; Siersema, P.D.; Borg, F. ter

    2017-01-01

    BACKGROUND: Traditionally, all patients with a malignant obstruction of the proximal colon (MOPC) are treated with emergency resection. However, recent data suggest that Self-expandable metallic stent (SEMS) placement could lower mortality and morbidity rates. This study therefore aimed to compare

  11. Retrograde placement of double-J ureteral stent with interventional therapy for the treatment of ureteral stricture

    International Nuclear Information System (INIS)

    Kong Jian; Xu Linfeng; Liang Huimin; Zheng Chuansheng; Zheng Jinlong; Feng Gansheng

    2000-01-01

    Objective: To evaluate the retrograde placement of Double-J ureteral stent with interventional therapy for the treatment of ureteral stricture. Methods: Twenty patients with ureteral stricture of various causes were treated with retrograde placing Double-J ureteral stent by interventional therapy. Results: The Double-J stent was successfully performed in all twenty patients. The successful rate of placing stent was 100%. The cure rate was 90% (18/20). The complications such as urinary leakage, wound infection, and bleeding were markedly decreased. The indication, duration of indwelling and complication of the indwelling stent were discussed. Conclusion: Retrograde placing Double-J stent with interventional therapy is simple and less invasive. It is believed to be a safe and effective method for the treatment of ureteral stricture

  12. Percutaneous unilateral biliary metallic stent placement in patients with malignant obstruction of the biliary hila and contralateral portal vein steno-occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Son, Rak Chae; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jong Woo; Ko, Gi Young [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    To investigate the outcomes of percutaneous unilateral metallic stent placement in patients with a malignant obstruction of the biliary hila and a contralateral portal vein steno-occlusion. Sixty patients with a malignant hilar obstruction and unilobar portal vein steno-occlusion caused by tumor invasion or preoperative portal vein embolization were enrolled in this retrospective study from October 2010 to October 2013. All patients were treated with percutaneous placement of a biliary metallic stent, including expanded polytetrafluoroethylene (ePTFE)-covered stents in 27 patients and uncovered stents in 33 patients. A total of 70 stents were successfully placed in 60 patients. Procedural-related minor complications, including self-limiting hemobilia (n = 2) and cholangitis (n = 4) occurred in six (10%) patients. Acute cholecystitis occurred in two patients. Successful internal drainage was achieved in 54 (90%) of the 60 patients. According to a Kaplan-Meier analysis, median survival time was 210 days (95% confidence interval [CI], 135-284 days), and median stent patency time was 133 days (95% CI, 94-171 days). No significant difference in stent patency was observed between covered and uncovered stents (p = 0.646). Stent dysfunction occurred in 16 (29.6%) of 54 patients after a mean of 159 days (range, 65-321 days). Unilateral placement of ePTFE-covered and uncovered stents in the hepatic lobe with a patent portal vein is a safe and effective method for palliative treatment of patients with a contralateral portal vein steno-occlusion caused by an advanced hilar malignancy or portal vein embolization. No significant difference in stent patency was detected between covered and uncovered metallic stents.

  13. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  14. Flexible endoscopy for pediatric tracheobronchial metallic stent placement, maintenance and long-term outcomes

    Science.gov (United States)

    2018-01-01

    Objectives To assess the placement, surveillance management and long-term outcomes of the tracheobronchial (TB) balloon expandable metallic stent (BEMS) managed by therapeutic flexible endoscopy (TFE). Methods This is a retrospective review and analysis of all computerized medical records and related flexible endoscopy videos of pediatric patients who received TB BEMS during 20 years period, from January 1997 to December 2016. TFE techniques with forceps debridement, balloon dilatation and laser ablation were used to implant stents, perform regular surveillance, maintain their functions, and expand the diameters of BEMS. Short-length (30cm-36cm) endoscopes of OD 3.2mm to 5.0mm coupled with the noninvasive ventilation, without ventilation bag, mask or airway tube, supported the whole procedures. Results 146 BEMS were implanted in 87 consecutive children, including 84 tracheal, 15 carinal and 47 bronchial stents. At the time of placement, the mean age was 35.6 ± 54.6 month-old (range 0.3–228) and the mean body weight was 13.9 ± 10.6 kg (range 2.2–60). Surveillance period was 9.4 ± 6.7 years (range, 0.3–18.0). Satisfactory clinical improvements were noted immediately in all but two patients. Seventy-two (82.8%) patients were still alive with stable respiratory status, except two patients necessitating TFE management every two months. Fifty-one stents, including 35 tracheal and 16 bronchial ones, were successfully retrieved mainly with rigid endoscopy. Implanted stents could be significantly (stent diameters were positively correlated to the implanted duration. Altogether, 33 stents expired (15 patients), 51 were retrieved (40 patients), and 62 remained and functioning well (38 patients), with their mean duration of 7.4 ± 9.5, 34.9 ± 36.3 and 82.3 ± 62.5 months, respectively. Conclusion In pediatric patients, TFE with short-length scopes coupled with this NIV support has provided a safe, feasible and effective modality in placing and subsequently managing

  15. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-02-15

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  16. The Efficacy of the Coaxial Technique Using a 6-Fr Introducer Sheath in Stent Placement for Treating the Obstructions Proximal to the Descending Colon

    International Nuclear Information System (INIS)

    Chang, Il Soo; Park, Sang Woo; Hwang, Dae Yong; Seong, Moo Kyung; Joh, Hee Kyung; Yoon, So Young; Cho, Yo Han; Choe, Won Hyeok

    2011-01-01

    We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4: mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon

  17. Y-shaped bilateral self-expandable metallic stent placement for malignant hilar biliary obstruction: data from a referral center for palliative care.

    Science.gov (United States)

    Di Mitri, R; Mocciaro, F

    2014-01-01

    Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Twenty patients (9 males) were treated (mean age 64.2 ± 15.3 years). The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%), IIIa in 1 (5%), and IV in 14 (70%). The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL). One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months), 13 of the 20 patients (65%) had died. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration) as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  18. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  19. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  20. MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting

    International Nuclear Information System (INIS)

    Clarke, M.G.; Thomas, H.G.; Chester, J.F.

    2005-01-01

    A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm

  1. Single-dose brachytherapy versus metal stent placement for the palliation of dysphagia from oesophageal cancer: multicentre randomised trial

    NARCIS (Netherlands)

    Homs, Marjolein Y. V.; Steyerberg, Ewout W.; Eijkenboom, Wilhelmina M. H.; Tilanus, Hugo W.; Stalpers, Lukas J. A.; Bartelsman, Joep F. W. M.; van Lanschot, Jan J. B.; Wijrdeman, Harm K.; Mulder, Chris J. J.; Reinders, Janny G.; Boot, Henk; Aleman, Berthe M. P.; Kuipers, Ernst J.; Siersema, Peter D.

    2004-01-01

    Background Both single-dose brachytherapy and self-expanding metal stent placement are commonly used for palliation of oesophageal obstruction due to inoperable cancer, but their relative merits are unknown. We under-took a randomised trial to compare the outcomes of brachytherapy and stent

  2. T-configured Dual Stent Placement in Malignant Biliary Hilar Obstruction: Technique and Clinical Application

    International Nuclear Information System (INIS)

    Jeon, Yong Sik; Kim, Ji Hyung

    2010-01-01

    To evaluate implanting techniques of T-configured dual stents in malignant hilar obstruction and investigate the clinical factors related to stent obstruction. The study included 28 patients undergoing T-configured dual stent implantation to palliate malignant biliary hilar obstruction. The unilobar approach was first attempted in the procedure, which progressed to bilobar approach when it was found that the unilobar approach was not feasible. If the stent was again obstructed, clinical palliation was attempted using stent re-insertion or PTBD. Clinical factors associated with T-configured dual stenting were examined in the patients with stent re-obstruction, which was followed by a correlation between these clinical factors and stent obstruction. Eleven of 13 patients were successfully treated by the unilobar approach. The two unsuccessful cases sustained angulation of the central large mesh stent. For the bilobar approach, 14 of 15 patients were successfully treated. For the one unsuccessful patient, the stent failed to pass through the central large mesh. Stent obstruction was revealed in 13 patients during the follow-up period. Balloon-assisted stent re-canalization was successfully performed in 5 patients. The analysis suggests that no definite correlation was found between stent obstruction and the clinical factors associated with dual stent placement. Conversely, bile containing sludge or debris was significantly correlated to early stent obstruction. Technical adoption considering the bile duct anatomy and obstruction pattern is important for T-configured dual stent implantation. The prudent evaluation of bile juice characters and cholangiographic findings is required for the appropriate clinical application of the T-configured dual stenting

  3. Combination of biodegradable stent placement and single-dose brachytherapy is associated with an unacceptably high complication rate in the treatment of dysphagia from esophageal cancer

    NARCIS (Netherlands)

    Hirdes, Meike M. C.; van Hooft, Jeanin E.; Wijrdeman, Harm K.; Hulshof, Maarten C. C. M.; Fockens, Paul; Reerink, Onne; van Oijen, Martijn G. H.; van der Tweel, Ingeborg; Vleggaar, Frank P.; Siersema, Peter D.

    2012-01-01

    Background: For the palliative treatment of dysphagia, esophageal stent placement provides immediate improvement, whereas brachytherapy offers better long-term relief. Objective: To evaluate safety and efficacy of concurrent brachytherapy and biodegradable stent placement. Design: Prospective,

  4. Argon Plasma Coagulation Combined with Covered Stent Placement for Management of Tracheobronchial Stenoses/occlusions as well as Esophagorespiratory Fistulas

    Directory of Open Access Journals (Sweden)

    Hongwu WANG

    2010-09-01

    Full Text Available Background and objective It is a complex problem and difficult treatment for tracheobronchial stenoses/occlusions involving in carina. The aim of this study is to investigate the feasibility and efficiency of argon plasma coagulation (APC and bifurcated covered Z-type stents (CZTS placement for the treatment of tracheobronchus stenoses and esophagorespiratory fistula (ERF. Methods Thirty-two cases with airway disorders were retrospectively reviewed for the treatment of APC and CZTS placement. Under the bronchoscopic guidance, APC was first given in patients with airway stenoses, then CZTS was placed under the fluoroscopic and flexible bronchoscopic guidance either with airway stenoses or ERF. Results APC was first given in 19 patients with airway stenoses. Airway structures were significantly improved after APC procedure (57.4%-72.1% before APC vs 12.8%-25.8% after APC. Thirty-two CZTS were technically successfully placed in 30 out of 32 cases involving in carinal bifurcation. After APC and stent placement, short breath index was significantly reduced and karnofsky physical score (KPS increased obviously. The endobronchial defects were successfully palliated with bifurcated CZTS placed under fluoroscopy and flexible bronchoscopy in 12 out of 13 patients with ERFs. There is no bleeding introprocedure. Mucous retention was very common in all types of the stents less than 2 weeks after stenting, which required debridement by bronchoscopy and could be prevented by normal saline solution nebulizations. Granuloma developed at the ends of stents after 1 month of stenting which all of them were treated successfully with APC and CO2 cryosurgery. Conclusion Utilization of APC and retrieval bifurcated CZTS placement is a simple and safe protocol for the management of airway complex stenoses involving the tracheal carina and ERF.

  5. Simultaneous Versus Sequential Side-by-Side Bilateral Metal Stent Placement for Malignant Hilar Biliary Obstructions.

    Science.gov (United States)

    Inoue, Tadahisa; Ishii, Norimitsu; Kobayashi, Yuji; Kitano, Rena; Sakamoto, Kazumasa; Ohashi, Tomohiko; Nakade, Yukiomi; Sumida, Yoshio; Ito, Kiyoaki; Nakao, Haruhisa; Yoneda, Masashi

    2017-09-01

    Endoscopic bilateral self-expandable metallic stent (SEMS) placement for malignant hilar biliary obstructions (MHBOs) is technically demanding, and a second SEMS insertion is particularly challenging. A simultaneous side-by-side (SBS) placement technique using a thinner delivery system may mitigate these issues. We aimed to examine the feasibility and efficacy of simultaneous SBS SEMS placement for treating MHBOs using a novel SEMS that has a 5.7-Fr ultra-thin delivery system. Thirty-four patients with MHBOs underwent SBS SEMS placement between 2010 and 2016. We divided the patient cohort into those who underwent sequential (conventional) SBS placement between 2010 and 2014 (sequential group) and those who underwent simultaneous SBS placement between 2015 and 2016 (simultaneous group), and compared the groups with respect to the clinical outcomes. The technical success rates were 71% (12/17) and 100% (17/17) in the sequential and simultaneous groups, respectively, a difference that was significant (P = .045). The median procedure time was significantly shorter in the simultaneous group (22 min) than in the sequential group (52 min) (P = .017). There were no significant group differences in the time to recurrent biliary obstruction (sequential group: 113 days; simultaneous group: 140 days) or other adverse event rates (sequential group: 12%; simultaneous group: 12%). Simultaneous SBS placement using the novel 5.7-Fr SEMS delivery system may be more straightforward and have a higher success rate compared to that with sequential SBS placement. This new method may be useful for bilateral stenting to treat MHBOs.

  6. Y-Shaped Bilateral Self-Expandable Metallic Stent Placement for Malignant Hilar Biliary Obstruction: Data from a Referral Center for Palliative Care

    Directory of Open Access Journals (Sweden)

    R. Di Mitri

    2014-01-01

    Full Text Available Background and Aim. Malignant hilar strictures are a clinical challenge because of the current therapeutic approach and the poor prognosis. In recent years, self-expandable metallic stents have proven more effective than plastic stents for palliation of malignant hilar strictures, with the bilateral stent-in-stent technique registering a high success rate. We report our experience with Y-shaped endoscopic self-expandable metallic stents placement for treatment of advanced malignant hilar strictures. Methods. From April 2009 to August 2012, we prospectively collected data on patients treated with Y-shaped SEMS placement for advanced malignant hilar carcinoma. Data on technical success, clinical success, and complications were collected. Results. Twenty patients (9 males were treated (mean age 64.2 ± 15.3 years. The grade of malignant hilar strictures according to the Bismuth classification was II in 5 patients (25%, IIIa in 1 (5%, and IV in 14 (70%. The mean bilirubin level was 14.7 ± 4.9 mg/dL. Technical success was achieved in all patients, with a significant reduction in bilirubin levels (2.9 ± 1.7 mg/dL. One patient experienced cholangitis as early complication, while in 2 patients stent ingrowth was observed. No stents migration was recorded. There was no procedure-related mortality. At the end of the follow-up (7.1 ± 3.1 months, 13 of the 20 patients (65% had died. Conclusions. Our experience confirms endoscopic bilateral self-expandable metallic stents placement with stent-in-stent technique (Y-shaped configuration as a feasible, effective, and safe procedure for palliation of unresectable malignant hilar strictures.

  7. The Effect of Ureteral Stent Placement Before Radical Prostatectomy on the Safety of Ureteral Dissection and the Surgeon’s Comfort

    OpenAIRE

    Fatih Akdemir; Emrah Okulu; Önder Kayıgil

    2017-01-01

    Objective: This study investigated the role of preoperative ureteral stent placement in reducing the risk of ureteral injury, an intraoperative complication of radical retropubic prostatectomy (RRP), and its contribution to the surgeon’s comfort. Materials and Methods: Open RRP was performed in 66 patients diagnosed with localized prostate cancer in our clinic between 2010 and 2015. The patients were divided into two groups; group 1 (n=34) underwent surgery without ureteral stent placement...

  8. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  9. Pseudoaneurisme på arteria carotis interna behandlet med stent

    DEFF Research Database (Denmark)

    Benian, Cemil; Wagner, Aase; Cortsen, Marie

    2013-01-01

    Extracranial internal carotid artery aneurysms (EACIAs) are rare. Untreated they have a high stroke rate. Traditionally the treatment has been surgery or endovascular intervention with coils. Both are associated with relatively high complication rates. Another treatment option is endovascular int...... intervention with covered stent, which provides one-step closure of the aneurysm. As in the case story it can be complicated with in-stent occlusion. Therefore we recommend balloon occlusion test before treatment of EACIAs with covered stent....

  10. Angioplasty and stent placement in the treatment of radiation-induced arterial injury

    International Nuclear Information System (INIS)

    Liu Pengcheng; Pierre, P.; Philippe, O.; Danial, C.; Jean-Paul, B.; Cyril, B.; Jean-Pierre, C.; Denis, K.; Helve, R.; Francis, J.

    1999-01-01

    Objective: Evaluation of therapeutic efficacy and longterm patency of angioplasty and stent for the treatment of radiation induced arterial disease. Methods: PTA was attempted in 18 arterial lesions following irradiation in 14 patients. Thirteen stents were placed in 8 patients to treat occlusion (n = 3), aneurysm (n = 1), residual stenosis (n =2), multiple stenoses (n = 1), and delayed restenosis after previous balloon angioplasty (n = 1). The stents were readily visualized and patency of the stent and the target artery determined with Doppler US and (or) CT in all patients. Results: Interventional procedure was successful in 14 patients of which 8 underwent stent placement for their arterial lesions. Eleven of these patients demonstrated primary patency with relief of clinical symptoms with a mean follow-up of 2 years (range, 8 months -60 months). Clinical improvement was noted for the other patients. Eleven patients underwent PTA once or twice. One patient had PTA four times and three stents were installed, two of which were in the area of the aortic bifurcation, and one in the celiac trunk. another patient also had PTA four times and two stents were placed in the superior mesenteric artery. A stent was implanted in one patient because of PTA induced dissection and occlusion, and the arterial lesion was considered to be cured clinically after a follow-up of 5 years. Conclusions: The results suggested that PTA with single or multiple techniques may be effective immediately in the treatment of arterial lesions caused by radiation and can be considered the first therapeutic option in these cases

  11. Duplex evaluation following femoropopliteal angioplasty and stenting: criteria and utility of surveillance.

    Science.gov (United States)

    Baril, Donald T; Marone, Luke K

    2012-07-01

    Surveillance following lower extremity bypass, carotid endarterectomy, and endovascular aortic aneurysm repair has become the standard of care at most institutions. Conversely, surveillance following lower extremity endovascular interventions is performed somewhat sporadically in part because the duplex criteria for recurrent stenoses have been ill defined. It appears that duplex surveillance after peripheral endovascular interventions, as with conventional bypass, is beneficial in identifying recurrent lesions which may preclude failure and occlusion. In-stent stenosis following superficial femoral artery angioplasty and stenting can be predicted by both peak systolic velocity and velocity ratio data as measured by duplex ultrasound. Duplex criteria have been defined to determine both ≥50% in-stent stenosis and ≥80% in-stent stenosis. Although not yet well studied, it appears that applying these criteria during routine surveillance may assist in preventing failure of endovascular interventions.

  12. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  13. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  14. Short-Term Biliary Stent Placement Contributing Common Bile Duct Stone Disappearance with Preservation of Duodenal Papilla Function

    Directory of Open Access Journals (Sweden)

    Tatsuki Ueda

    2016-01-01

    Full Text Available Aims. To investigate the effect of biliary stent placement without endoscopic sphincterotomy (EST on common bile duct stones (CBDS disappearance and the contribution of preserving the duodenal papilla function to reduce recurrence of CBDS. Methods. Sixty-six patients admitted for acute obstructive cholangitis due to CBDS who underwent biliary stent placement without EST for 2 years from March 2011 were evaluated retrospectively. The second endoscopic retrograde cholangiopancreatography (ERCP was performed for treatment of CBDS 3 to 4 months after the first ERCP. We estimated the rate of stone disappearance at the time of second ERCP. Results. CBDS disappearance was observed in 32 (48.5% of 66 patients. The diameter of the bile ducts and the diameter of CBDS in patients with CBDS disappearance were significantly smaller than in those with CBDS requiring extraction (p=0.007 and p<0.001, resp.. Stone disappearance was evident when the diameter of bile ducts and that of CBDS were <10 and 7 mm, respectively (p=0.002. Conclusions. Short-term stent placement without EST eliminates CBDS while preserving duodenal papilla function and may be suitable for treating CBDS in patients with nondilated bile ducts and small CBDS.

  15. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  16. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  17. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  18. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  19. Endovascular treatment for extrahepatic portal vein bifurcation stenosis after a Whipple procedure using the kissing stents technique.

    Science.gov (United States)

    Zhang, Wen-guang; Liu, Dong-mei; Li, Zhen; Wang, Yan-Li; Ding, Peng-xu; Zhou, Peng-li; Wang, Zhong-gao; Han, Xin-wei

    2014-01-01

    A 57-year-old man presented with a rare extrahepatic portal vein bifurcation scar stenosis involving the proximal splenic vein and superior mesenteric vein after a Whipple procedure. He was treated with endovascular coil embolization for the gastroesophageal varices and kissing stents for the portal vein bifurcation stenosis. This case illustrates a rarely seen complication after the Whipple procedure and a novel management strategy that can be considered in the management of this complex disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    International Nuclear Information System (INIS)

    Wu, Tian-Tian; Li, Hu-Cheng; Zheng, Fang; Ao, Guo-Kun; Lin, Hu; Li, Wei-Min

    2016-01-01

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  1. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  2. Clinical remission following endoscopic placement of retrievable, fully covered metal stents in patients with esophageal achalasia.

    Science.gov (United States)

    Zeng, Y; Dai, Y-M; Wan, X-J

    2014-01-01

    Metal stents may represent an alternative therapy in the treatment of achalasia. We therefore evaluated the effectiveness of retrievable, fully covered metal stents in patients with achalasia. Fifty-nine patients with achalasia were treated with retrievable, fully covered metal stents. Symptoms using a global symptom score (0-10), lower esophageal sphincter (LES) resting pressure, LES relaxation, and simultaneous contraction of the esophagus were analyzed before and 1 week and 1 month after intervention. Complications and treatment outcomes were followed up at 6, 12, 18, and 24 months postoperatively. Stent placement was successful, and clinical symptoms resolved (P treatment in patients with achalasia. © 2013 Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  3. [Complications and the management of fully covered retrievable metal stent placement in benign tracheal stenosis].

    Science.gov (United States)

    Wang, Zheng-yu; Wang, Yong-li; Chen, Guang-li; Liang, Xi-hong; Wang, Zhen-chang; Ma, Jian-zhong; Wu, Guang-zhong; Zhang, Xiao-ping

    2012-11-01

    To study complications and the management of the use of covered retrievable expandable metallic stents in the treatment of benign tracheal stenosis. Fully covered retrievable metal stents were placed in 21 patients with benign tracheal stenosis. Stent-related complications and the management were reviewed and analysed. Twenty-eight fully covered retrievable metallic stents were successfully placed fluoroscopically in 21 patients. Stents were removed 4 - 12 months [mean (5.5 ± 2.2) mouths] after placement in all patients. Stent-related complications included granulation tissue (n = 18), stent migration (n = 4), stent expectoration (n = 2), halitosis (n = 8), mucous retention (n = 21) and mucus plugging (n = 1). Granulation tissue was removed with a carbon dioxide laser in 2 patients. Stents were replaced for 2 times and 3 times respectively in 2 patients after stent migration and stent expectoration. An additional stent was placed in 2 patients after stent migration. Symptom of halitosis was relieved after prolonged course of systemic antibiotics treatment in 8 patients. Symptom of mucous retention was relieved with nebulized saline and N-acetylcysteine saline inhalation. Mucous plug was expelled after severe coughing after suctioning using an aspirator in one patient. There were statistically significant differences in stricture diameter, rank of tachypnea and pulmonary function (FEV(1)) in all 21 patients before stent insertion and after stents removal. No patient has experienced recurrence during the follow-up period of 1 - 36 months [mean (23.2 ± 8.0) months]. Fully covered retrievable metallic stent may be a safe and effective in benign tracheal stenosis. Stent-related complications may be effectively managed.

  4. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  5. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  6. Esophageal leiomyoma in a dog causing esophageal distension and treated by transcardial placement of a self-expanding, covered, nitinol esophageal stent.

    Science.gov (United States)

    Robin, Elisabeth M; Pey, Pascaline B; de Fornel-Thibaud, Pauline; Moissonnier, Pierre H M; Freiche, Valérie

    2018-02-01

    CASE DESCRIPTION A 10-year-old spayed female Rottweiler was referred for evaluation because of a 2-month history of regurgitation and weight loss, despite no apparent change in appetite. The dog had received antiemetic and antacid treatment, without improvement. CLINICAL FINDINGS Physical examination revealed a low body condition score (2/5), but other findings were unremarkable. Diffuse, global esophageal dilatation was noted on plain thoracic radiographs, and normal motility was confirmed through videofluoroscopic evaluation of swallowing. Transhepatic ultrasonographic and CT examination revealed a circumferential, intraparietal lesion in the distal portion of the esophagus causing distal esophageal or cardial subobstruction and no metastases. Incisional biopsy of the lesion was performed, and findings of histologic examination supported a diagnosis of esophageal leiomyoma. TREATMENT AND OUTCOME In view of numerous possible complications associated with esophageal surgery, the decision was made to palliatively treat the dog by transcardial placement of a self-expanding, covered, nitinol esophageal stent under endoscopic guidance. Two weeks after stent placement, radiography revealed complete migration of the stent into the gastric lumen. Gastrotomy was performed, and the stent was replaced and fixed in place. Twenty-four months after initial stent placement, the dog had a healthy body condition and remained free of previous clinical signs. CLINICAL RELEVANCE Diffuse benign muscular neoplasia should be considered as a differential diagnosis for acquired esophageal dilatation in adult and elderly dogs. In the dog of this report, transcardial stent placement resulted in resolution of the clinical signs, with no apparent adverse effect on digestive function. The described procedure could be beneficial for nonsurgical treatment of benign esophageal tumors in dogs.

  7. Treatment of Occluded Distal Splenorenal Shunts with Endovascular Stents: A Report of Two Cases

    International Nuclear Information System (INIS)

    Lopez-Medina, Antonio; Peiro, Javier; Gonzalez de Garay, Miguel; Antonana, Miguel A.; Sustacha, Jon; Grande, Domingo

    2001-01-01

    Surgical treatment of an occluded or stenotic portosystemic shunt is difficult and carries a high risk of mortality. We report two cases of early thrombosis of distal splenorenal shunt (DSRS) successfully treated by transcatheter recanalization and stent placement. At 18-month follow-up, the patients remained asymptomatic and control venograms showed continued patency of the shunt with no evidence of stenosis or collaterals

  8. Complication after self expandable metallic stent for esophageal cancer

    International Nuclear Information System (INIS)

    Nagahama, Takeshi; Maruyama, Michio; Kato, Kiyomi; Shinoura, Hiroshi; Hasegawa, Kumi; Takashima, Itaru; Ebuchi, Masakazu

    2003-01-01

    Major complications after placement of esophageal stent and airway stent were reviewed and evaluated. Four patients, including two patients with perforations and two patients with fistula formation, developed major complications after placement of a self expandable metallic stent. Two patients underwent additional radiation to improve stricture after stent placement. In one patient, stent placement was selected to improve esophageal stricture that occurred after radical radiation therapy. In one patient, migration of stent into the lesion caused a perforation. It can be concluded that additional radiation after stent placement increases the risk of complication. Stent migration also can lead to the risk of perforation. (author)

  9. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  10. Endovascular management of an acquired aortobronchial fistula following aortic bypass for coarctation.

    LENUS (Irish Health Repository)

    O'Sullivan, Katie E

    2013-09-20

    Aortobronchial fistula (ABF) in the setting of aortic coarctation repair is very rare but uniformly fatal if untreated. Endovascular stenting of the descending aorta is now the first-choice approach for ABF presenting with haemoptysis and offers a less-invasive technique with improved outcomes, compared with open repair. We report a case of late ABF occurring following bypass for aortic coarctation. Management focused on two key manoeuvres: use of a covered endovascular stent to occlude the aortic bypass thus controlling the fistula and dilatation and stenting of native coarctation.

  11. Reversal of end-stage renal disease after aortic dissection using renal artery stent: a case report

    Directory of Open Access Journals (Sweden)

    Parikh Chirag R

    2004-05-01

    Full Text Available Abstract Background Medical management is the conventional treatment for Stanford Type B aortic dissections as surgery is associated with significant morbidity and mortality. The advent of endovascular interventional techniques has revived interest in treating end-organ complications of Type B aortic dissection. We describe a patient who benefited from endovascular repair of renal artery stenosis caused by a dissection flap, which resulted in reversal of his end-stage renal disease (ESRD. Case presentation A 69 y/o male with a Type B aortic dissection diagnosed two months earlier was found to have a serum creatinine of 15.2 mg/dL (1343.7 μmol/L on routine visit to his primary care physician. An MRA demonstrated a rightward spiraling aortic dissection flap involving the origins of the celiac artery, superior mesenteric artery, and both renal arteries. The right renal artery arose from the false lumen with lack of blood flow to the right kidney. The left renal artery arose from the true lumen, but an intimal dissection flap appeared to be causing an intermittent stenosis of the left renal artery with compromised blood flow to the left kidney. Endovascular reconstruction with of the left renal artery with stent placement was performed. Hemodialysis was successfully discontinued six weeks after stent placement. Conclusion Percutaneous intervention provides a promising alternative for patients with Type B aortic dissections when medical treatment will not improve the likelihood of meaningful recovery and surgery entails too great a risk. Nephrologists should therefore be aggressive in the workup of ischemic renal failure associated with aortic dissection as percutaneous intervention may reverse the effects of renal failure in this population.

  12. Endovascular Treatment of Central Vein Stenoses and/or Occlusions in Hemodialysis Patients

    International Nuclear Information System (INIS)

    Maskova, Jana; Komarkova, Jana; Kivanek, Jiri; Danes, Jan; Slavikova, Marcela

    2003-01-01

    Purpose: To report our experience and results with the endovascular treatment of central vein stenoses and occlusions in hemodialysis patients. Methods: Between October 1999 and August 2001 (22 months) we performed 22 interventional procedures in 14 hemodialysis patients (8 women, 6 men) ranging in age from 38 to 87 years (mean 76 years). The indication for intervention was stenosis (n = 10) or occlusion (n =4) of a central vein in the upper arm used for dialysis inpatients with arm swelling and/or shunt malfunction. All patients had a previous history of subclavian vein cannulation. There were six percutaneous transluminal angioplasties (PTAs) and eight primary stentplacements and eight repeat interventions. Seven were for restenoses and one for early occlusion, with two secondary stent placements and six PTA of in-stent stenoses. In two patients a second stent was implanted. The mean follow-up was 8.5 months (range 1-19 months). All stents were self-expandable with diameters ranging from 9 to 16 mm. Results: All but one of the procedures was technically successful (95%, n = 21). The patient with an unsuccessful procedure died 1 month after the procedure, but the death was not procedure-related. During follow-up three patients died with a patent shunt and central vein, none of them in connection with the procedure. No complication occurred during the interventional procedures. One patient was lost to follow-up. The primary patency rate at 12 months was 43%, with a primary assisted patency rate of 83% and a secondary patency rate of 100% (n 6). Conclusion: Central vein stenoses and occlusions are associated with previous subclavian vein cannulation. They are a serious problem in hemodialysis patients with a shunt on the same arm.Endovascular treatment is a suitable option for these patients

  13. Multimodal Therapy for the Treatment of Severe Ischemic Stroke Combining Endovascular Embolectomy and Stenting of Long Intracranial Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Matjaž Bunc

    2010-01-01

    Case Report. We present a case of a 49-year-old female patient who—according to the National Institute of Health Stroke Scale (NIHSS—was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA. After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach—without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA.

  14. A comparison of the temporary placement of 3 different self-expanding stents for the treatment of refractory benign esophageal strictures: a prospective multicentre study

    Directory of Open Access Journals (Sweden)

    Canena Jorge Manuel

    2012-06-01

    Full Text Available Abstract Background Refractory benign esophageal strictures (RBESs have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs, biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs, for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10, biodegradable stents (n = 10 or FCSEMSs (12 weeks, n = 10. Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60% in the SEPS group, 2 (20% in the biodegradable group and 3 (30% in the FCSEMS group (P = 0.16. A total of 8/30 patients (26.6% were dysphagia-free after the end of follow-up: 1 (10% in the SEPS group, 3 (30% in the biodegradable group and 4 (40% in the FCSEMS group (P = 0.27. More reinterventions were required in the SEPS group (n = 24 than in the biodegradable group (n = 13 or the FCSEMS group (n = 13 (P = 0.24. Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011. Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence.

  15. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    Science.gov (United States)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  16. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    International Nuclear Information System (INIS)

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H.; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M.; Borm, Paul J. A.; Jacob, Augustinus L.; Bilecen, Deniz

    2009-01-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  17. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  18. [Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis].

    Science.gov (United States)

    Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M

    2002-03-01

    To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.

  19. Outcomes and complications of self-expanding metal stent placement for malignant colonic obstruction in a single-center study.

    Science.gov (United States)

    Stankiewicz, Rafał; Kozieł, Sławomir; Pertkiewicz, Jan; Zieniewicz, Krzysztof

    2018-03-01

    Approximately 20% of cases of colorectal cancer are accompanied by acute colonic obstruction. While emergency colonic surgery is associated with high mortality and morbidity rates, placement of a self-expanding metal stent (SEMS) has been suggested as an alternative method. The SEMS placement can serve as either a definitive treatment in palliative cases or a bridge to surgery. To summarize the experience of our center in the treatment of malignant colonic obstruction using SEMS placement. A retrospective review was conducted of all patients who underwent a SEMS placement for colorectal stricture in the study period. The procedures were performed under fluoroscopic guidance with colonoscopic assistance, and uncovered stents were used in all patients. The study population consisted of 28 patients treated with SEMS placement due to malignant colonic obstruction. The majority of procedures were performed with palliative intent. The overall technical success rate was 96.5%, and clinical success was achieved in all of the successfully placed SEMSs. One fatal complication due to colonic perforation occurred. In the bridge-to-surgery group, all patients experienced tumor resection with no stoma creation. The SEMS placement is an optimal treatment in the vast majority of acute colonic obstruction cases. Due to the possibility of potentially fatal complications, SEMS procedures should be performed by proficient endoscopists.

  20. Endoscopic placement of ureteral stents for treatment of congenital bilateral ureteral stenosis in a dog.

    Science.gov (United States)

    Lam, Nathaniel K; Berent, Allyson C; Weisse, Chick W; Bryan, Christine; Mackin, Andrew J; Bagley, Demetrius H

    2012-04-15

    A 5-year-old 8.6-kg (18.9-lb) spayed female Pug was evaluated because of chronic hematuria and recurrent urinary tract infections. Excretory urography, ultrasonography, and excretory CT urography were performed. Results indicated that the dog had bilateral hydronephrosis and hydroureter and suspected proximal ureteral stenosis. Retrograde ureteropyelography confirmed the presence of stenosis at the ureteropelvic junction of each ureter, along with a large amount of endoluminal ureteral debris. Clinical findings suggested that the dog had a congenital bilateral anomaly of the upper urinary tract. The dog was anesthetized, and 2 double-pigtail ureteral stents were placed cystoscopically with fluoroscopic guidance for immediate relief of the ureteropelvic junction obstructions. Each stent extended from the left or right renal pelvis to the urinary bladder. The procedures and the patient's recovery from anesthesia were uncomplicated. Continuing improvements in severity of hydronephrosis, hydroureter, and dysuria were evident during routine follow-up examinations at 2, 4, 12, 16, and 45 weeks after stent placement. Over the subsequent 12 months, all clinical signs remained resolved other than a urinary tract infection that was successfully treated with antimicrobials. Ureteral stenosis should be considered as a differential diagnosis for hydronephrosis in dogs, particularly when urinary tract calculi or neoplasia is not present. Chronic hematuria and recurrent urinary tract infections can be associated with this condition. Placement of ureteral stents may be a successful treatment option for ameliorization of congenital ureteral obstructions.

  1. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  2. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  3. Vertebral artery ostial stent placement for atherosclerotic stenosis in 72 consecutive patients: clinical outcomes and follow-up results

    International Nuclear Information System (INIS)

    Taylor, Robert A.; Memon, Muhammad Zeeshan; Qureshi, Adnan I.; Vazquez, Gabriela; Siddiq, Farhan; Hayakawa, Minako; Chaloupka, John C.

    2009-01-01

    The study's purpose is to report the technical and clinical outcomes of a patient cohort that underwent vertebral artery ostium stent placement for atherosclerotic stenosis. We retrospectively analyzed a prospectively collected database of neurointerventional procedures performed at a single center from 1999 to 2005. Outcome measures included recurrent transient neurological deficits (TNDs), stroke, and death. Kaplan-Meier analysis was used to estimate stroke- and/or death-free survival at 12 months. Cox proportional hazard was used to identify risk factors for recurrent vertebrobasilar ischemic events. Seventy-two patients with 77 treated vertebral ostial lesions were included. The 30-day stroke and/or death rate was 5.2% (n = 4), although no event was directly related to the vertebral ostium stent placement. Three procedure-related strokes were secondary to attempted stent placement at other sites (one carotid artery and two basilar arteries), and the one death was secondary to the presenting stroke severity. The mean clinical follow-up time available for 66 patients was 9 months. There were 14 TNDs (21%), two strokes (3%), and two deaths (3%) recorded in the follow-up. Recurrent vertebrobasilar ischemic events occurred in nine patients (seven TNDs and two strokes). No recurrent stroke and/or deaths were related to the treated vertebral ostium. Stroke- and/or death-free survival rate (including periprocedural stroke and/or death) was 89 ± 5% at 12 months. No vascular risk factor was significantly associated with recurrent vertebrobasilar ischemic events. Vertebral artery ostium stent placement can be safely and effectively performed with a low rate of recurrent stroke in the territory of the treated vessel. Patients who also underwent attempted treatment of a tandem intracranial stenosis appeared to be at highest risk for periprocedure stroke. (orig.)

  4. Multiple plastic biliary stent placement in the management of large and multiple choledochal stones: single center experience and review of the literature.

    Science.gov (United States)

    Bektaş, Hasan; Gürbulak, Bünyamin; Şahin, Zeynep Deniz; Düzköylü, Yiğit; Çolak, Şükrü; Gürbulak, Esin Kabul; Güneş, Mehmet Emin; Çakar, Ekrem

    2017-09-01

    Endoscopic retrograde cholangiopancreatography (ERCP) with sphincterotomy is the first step treatment modality of choledocholithiasis. In spite of an extended sphincterotomy, 10-15% of complex choledochal stones (larger than 15 mm and/or more than 3 stones) cannot be removed and recurrent ERCP procedures may be needed. To evaluate the role and efficiency of multiple biliary stent application in the treatment of large and multiple choledochal stones. Patients with complex choledochal stones and patients with inadequate choledochal clearance during ERCP were included in the study. The study group was divided into 2 groups as the placement of single (n = 27 patients) or multiple stents (n = 58 patients). After a mean time interval of 21 days (10-28), the ERCP procedure was tried for the second time and a stent was placed in case of recurrence. Successful biliary drainage was provided in both groups. The decrease in the longitudinal or transverse size of the stones after stent placement was found to be statistically significant in both groups (p = 0.001). Cholestatic enzymes (alkaline phosphatase (ALP), γ-glutamyltransferase (GGT)) and bilirubin levels decreased significantly in both groups following stenting (p = 0.001). Additionally, multiple stents functioned as a bridge starting from the first ERCP to full clearance in patients with large and multiple stones which could not be removed at once and saved them from the possible morbidities of an invasive operation. Endoscopic multiple biliary stent placement should be preferred in the treatment of patients with complex choledochal stones and high rates of co-morbidity, as a safe alternative to surgery.

  5. Endovascular thrombectomy for M2 occlusions: comparison between forced arterial suction thrombectomy and stent retriever thrombectomy.

    Science.gov (United States)

    Kim, Yong-Won; Son, Seungnam; Kang, Dong-Hun; Hwang, Yang-Ha; Kim, Yong-Sun

    2017-07-01

    To date there has been no direct comparison of two frequently used endovascular thrombectomy (EVT) methods (forced arterial suction thrombectomy (FAST) and stent retriever thrombectomy) in M2 occlusions. We review our experiences with EVT performed using FAST and stent retriever thrombectomy in such cases. The subjects comprised 41 patients with an M2 occlusion who underwent EVT (25 with FAST, 16 with stent retriever thrombectomy). The patients' data were retrospectively analyzed to evaluate the technical characteristics and angiographic outcome of the two EVT techniques. Thrombolysis In Cerebral Infarction (TICI) grades 2b-3 using the first chosen technique did not differ significantly between the two techniques (FAST 64.0% vs stent retriever thrombectomy 81.2%, p=0.305). Time from groin puncture to reperfusion was significantly shorter for stent retriever thrombectomy (53.0 vs 38.5 min; p=0.045). Distal embolization occurred in three cases (12.0%) in the FAST group and in four (26.7%) in the stent retriever group (p=0.362). However, the two techniques did not differ significantly in the final TICI 2b-3 rate (72.0% vs 87.5%; p=0.441). A frequent angiographic finding regarding the failure of FAST was that the M2 occlusion was located immediately after severe acute angulation between M1 and M2. Stent retriever thrombectomy may provide faster reperfusion than FAST, while the FAST technique might be associated with lower distal embolization and a higher reperfusion rate for the first thrombectomy attempt, but without any significant difference in clinical outcome. When choosing the EVT method for M2 occlusions, consideration of the location of the occlusion and tortuosity between M1 and M2 might be helpful to achieve a better angiographic outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    International Nuclear Information System (INIS)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong

    2017-01-01

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT

  7. Emergent intracranial balloon angioplasty and bailout self-expandable stent placement in acute large vessel occlusion of the anterior circulation: Experience of a single institution

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Young Jin; Seo, Jung Hwa; Jeong, Hae Woong [Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-06-15

    To evaluate the outcomes of angioplasty for recanalization after acute ischemic stroke (AIS). The study population was selected from 134 patients who underwent endovascular revascularization therapy (ERT) for AIS between October 2011 and May 2014. Of those 134 patients, 39 who underwent balloon angioplasty with or without stent insertion were included in this study. Balloon angioplasty was the primary treatment for nine patients and a rescue method for 30 patients. The revascularization rate at 7 days, procedure-related complications, and clinical outcomes at 3 months were analyzed. The occlusion sites were the middle cerebral artery (n = 26), intracranial internal carotid artery (n = 10), and middle cerebral artery branch (n = 3). Angioplasty achieved successful revascularization (Thrombolysis in Cerebral Ischemia grade 2b–3) in 76.9% of patients. Computed tomography angiography performed 7 days post-procedure revealed a maintained reperfusion in 82.8% of successful cases. Only two patients had symptomatic intracerebral hemorrhage. At the 3-month follow-up, 18 (48.6%) and 10 (27.0%) patients showed good and poor functional outcomes, respectively (modified Rankin Scale scores, 0–2 and 5–6). Emergent balloon angioplasty and bailout self-expandable stent placement may be safe and effective for achieving successful revascularization in acute large vessel occlusion of the anterior circulation. It could be a feasible rescue method as well as a primary method for ERT.

  8. Comparison of Covered Versus Uncovered Stents for Benign Superior Vena Cava (SVC) Obstruction.

    Science.gov (United States)

    Haddad, Mustafa M; Simmons, Benjamin; McPhail, Ian R; Kalra, Manju; Neisen, Melissa J; Johnson, Matthew P; Stockland, Andrew H; Andrews, James C; Misra, Sanjay; Bjarnason, Haraldur

    2018-05-01

    To identify whether long-term symptom relief and stent patency vary with the use of covered versus uncovered stents for the treatment of benign SVC obstruction. We retrospectively identified all patients with benign SVC syndrome treated to stent placement between January 2003 and December 2015 (n = 59). Only cases with both clinical and imaging follow-up were included (n = 47). In 33 (70%) of the patients, the obstruction was due to a central line or pacemaker wires, and in 14 (30%), the cause was fibrosing mediastinitis. Covered stents were placed in 17 (36%) of the patients, and 30 (64%) patients had an uncovered stent. Clinical and treatment outcomes, complications, and the percent stenosis of each stent were evaluated. Technical success was achieved in all cases at first attempt. Average clinical and imaging follow-up in years was 2.7 (range 0.1-11.1) (covered) and 1.7 (range 0.2-10.5) (uncovered), respectively. There was a significant difference (p = 0.044) in the number of patients who reported a return of symptoms between the covered (5/17 or 29.4%) and uncovered (18/30 or 60%) groups. There was also a significant difference (p = stenosis after stent placement between the covered [17.9% (range 0-100) ± 26.2] and uncovered [48.3% (range 6.8-100) ± 33.5] groups. No significant difference (p = 0.227) was found in the time (days) between the date of the procedure and the date of clinical follow-up where a return of symptoms was reported [covered: 426.6 (range 28-1554) ± 633.9 and uncovered 778.1 (range 23-3851) ± 1066.8]. One patient in the uncovered group had non-endovascular surgical intervention (innominate to right atrial bypass), while none in the covered group required surgical intervention. One major complication (SIR grade C) occurred that consisted of a pericardial hemorrhagic effusion after angioplasty that required covered stent placement. There were no procedure-related deaths. Both covered and uncovered stents can be used for

  9. Intestinal infarction: A complication of endovascular therapy

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; Sukumar, Sathi; Thompson, David; Roulson, Jo-An; Pritchard, Susan; Ashleigh, Raymond J.

    2007-01-01

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain

  10. Intestinal infarction: A complication of endovascular therapy

    Energy Technology Data Exchange (ETDEWEB)

    England, Andrew [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)]. E-mail: andrew.england@smtr.nhs.uk; Butterfield, John S. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Sukumar, Sathi [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Thompson, David [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Roulson, Jo-An [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Pritchard, Susan [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Ashleigh, Raymond J. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)

    2007-08-15

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain.

  11. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  12. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    NARCIS (Netherlands)

    Onuta, Geanina; Groenewegen, Hendrik C.; Klatter, Flip A.; Boer, Mark Walther; Goris, Maaike; van Goor, Harry; Roks, Anton J. M.; Rozing, Jan; de Smet, Bart J. G. L.; Hillebrands, Jan-Luuk

    2011-01-01

    Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on development of

  13. Long-term type 1 diabetes enhances in-stent restenosis after aortic stenting in diabetes-prone BB rats

    NARCIS (Netherlands)

    J.-L. Hillebrands (Jan-Luuk); G. Onuta (Geanina); H.C. Groenewegen (Hendrik); F.A. Klatter (Flip); M. Walther Boer (Mark); M. Goris (Maaike); H. van Goor (Harry); A.J.M. Roks (Anton); J. Rozing (Jan); B.J.G.L. de Smet (Bart)

    2011-01-01

    textabstractType 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s) of long-term autoimmune diabetes on

  14. A Case of Late Femoral Pseudoaneurysm Caused by Stent Disconnection

    International Nuclear Information System (INIS)

    Rivolta, Nicola; Fontana, Federico; Piffaretti, Gabriele; Tozzi, Matteo; Carrafiello, Gianpaolo

    2010-01-01

    We present the case of a late superficial femoral artery stent disconnection causing an asymptomatic pseudoaneurysm successfully treated with a stent-graft. A 67-year-old female was referred to our department for evaluation of claudication of the left lower limb and was diagnosed to have a total occlusion of the superficial femoral artery. Three nitinol stents were used to revascularize this artery. At 48 months, duplex-ultrasonography control revealed the presence of a 45-mm saccular femoral dilatation; X-rays and CT angiography showed fractures of the proximal stents and the presence of a pseudoaneurysm at the site of the distal stents disconnection. The pseudoaneurysm was excluded using two stent-grafts. We conclude that patients and surgeons should be aware of structural complications with all stents. Rigorous follow-up controls should be mandatory. Endovascular repair proved to be feasible and durable to manage a previous endovascular procedure.

  15. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... measurements, Mann-Whitney U test could discriminate between experts and novices (p = .002), between experts and intermediates (p = .010), and between novices and intermediates (p = .036). In stent selection the experts performed significantly better than both the novices and the intermediates (p = .002 and p...... of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and certification of future endovascular specialists....

  16. Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Zeebregts, Clark J.; Vourliotakis, George; Bekkema, Foppe; van den Dungen, Jan J. A. M.; Prins, Ted R.; Verhoeven, Eric L. G.

    Objective: During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes the incidence and origin of stein graft fractures after endovascular repair, its impact on patency, and strategies to prevent fractures.

  17. Retreatment and outcomes of recurrent intracranial vertebral artery dissecting aneurysms after stent assisted coiling: a single center experience.

    Directory of Open Access Journals (Sweden)

    Ying Song

    Full Text Available The retreatment of recurrent intracranial vertebral artery dissecting aneurysms (VADAs after stent assisted coiling (SAC has not yet been studied. The purpose of this study was to evaluate the strategies and outcomes for retreatment of recurrent VADAs after SAC.Between September 2009 and November 2013, six consecutive patients presenting with recurrent intracranial VADAs after SAC were enrolled in this study. They were all male with age ranging from 29 to 54 years (mean age, 46.2 years. The procedures of treatments and angiographic and clinical follow-up were reviewed retrospectively. Retreatment modalities were selected individually according to the characteristics of recurrence. The outcomes of retreatment were evaluated by angiographic and clinical follow-up.Six patients with recurrent intracranial VADAs after SAC were retreated, with second SAC in three patients, coil embolization, double overlapping stents placement and endovascular occlusion with aneurysm trapping in one patient, respectively. Immediate angiographic outcomes of retreatment were: complete occlusion in three patients, nearly complete occlusion in two patients, and contrast medium retention in dissecting aneurysm in one patient. All cases were technically successful. No complications related to endovascular procedures occurred. Angiographic follow-up was available in all five patients treated with second SAC or double overlapping stents, which was complete occlusion in four patients, obliteration of parent artery in one patient, showing no recurrence at 4-11 months (mean: 8.6 months. Clinical follow-up was performed in all six patients at 11-51 months after initial endovascular treatment and at 9-43 months after retreatment. The mRS of last clinical follow-up was excellent in five patients and mild disability in only one patient.Endovascular retreatment is feasible and effective for recurrent intracranial VADAs after SAC. Individualized strategies of retreatment should be

  18. Anesthetic and Airways Management of a Dog with Severe Tracheal Collapse during Intraluminal Stent Placement

    Directory of Open Access Journals (Sweden)

    M. Argano

    2013-01-01

    Full Text Available This case report describes the anesthetic and airways management of a dog affected by 4th degree tracheal collapse and undergoing endoscope-guided intraluminal stent placement. After premedication with acepromazine and butorphanol, general anesthesia was induced with propofol and maintained with intravenous propofol and butorphanol in constant rate infusion. During intraluminal stent placement, oxygen was supplemented by means of a simple and inexpensive handmade device, namely, a ureteral catheter inserted into the trachea and connected to an oxygen source, which allowed for the maintenance of airways’ patency and adequate patient’s oxygenation, without decreasing visibility in the surgical field or interfering with the procedure. The use of the technique described in the present paper was the main determinant of the successful anesthetic management and may be proposed for similar critical cases in which surgical manipulation of the tracheal lumen, which may potentially result in hypoxia by compromising airways patency, is required.

  19. Assessment of effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion using self-expanding Jaguar SM stents

    International Nuclear Information System (INIS)

    Kordecki, Kazimierz; Łukasiewicz, Adam; Nowicki, Mirosław; Lewszuk, Andrzej; Kowalewski, Radosław; Panek, Bogusław; Zawadzki, Michał; Michalak, Paweł; Gacko, Marek; Łebkowska, Urszula

    2012-01-01

    The goal of this work was to assess the effectiveness of endovascular treatment of common and external iliac artery stenosis/occlusion classified according to TASC using a self-expanding stent Jaguar SM. The study group included 95 patients (61 men and 34 women) who underwent treatment for stenosis or occlusion of lower limb arteries at the Department of Radiology of the University Hospital in Bialystok and the Diagnostic Radiology Department of the Central Clinical Hospital of the Ministry of Interior (MSWiA) in Warsaw between 2005 and 2007. All arterial lesions were of atherosclerotic etiology. The shortest stenotic fragment was 10 mm long and the longest occluded arterial fragment did not exceed 90 mm. Morphological classification of iliac artery lesions in treated patients was performed according to TASC II classification and included 10 patients with type A, 39 cases of type B, 36 with type C and 10 patients with type D lesions. Endovascular procedure failed to restore flow in five patients with TASC type D lesions, who were later referred for surgery. One patient suffered a complication – vessel perforation during predilatation, and had a stentgraft implanted. In 95% of patients stents were expanded using a balloon after implantation. Good results were achieved in practically all patients who underwent stent implantation. Patients were subjected to follow-up clinical and imaging evaluation during next 1–24 months. Success rate of the performed procedures as well as in a 30-day observation period was 100% in case of stenosis and 80% in case of vessel occlusion. A follow-up after 12 and 24 months showed patency of treated vessels in 84% and 76% of patients, respectively

  20. Temporary placement of covered self-expandable metallic stents in the management of benign biliary strictures.

    Science.gov (United States)

    Yasuda, Ichiro; Mukai, Tsuyoshi; Doi, Shinpei; Tomita, Eiichi; Moriwaki, Hisataka

    2012-05-01

    Currently, endoscopic intervention is widely attempted as the first-line treatment of benign biliary strictures because of its convenience and low morbidity. Plastic tube stents (PS) are usually used for such treatment; however, covered self-expandable metallic stents (C-SEMS) are becoming more commonly used at some institutions. The temporary placement of C-SEMS may lead to better outcomes because of their larger diameter and, therefore, better dilation of the stricture, especially in refractory cases. The aim of the present study was to evaluate the efficacy of the temporary placement of C-SEMS in the management of benign biliary strictures. We retrospectively reviewed our endoscopic retrograde cholangiopancreatography (ERCP) database (May 1996 to December 2010), and extracted the data of patients who underwent endoscopic treatment for benign biliary strictures. Then, the follow-up data from patient charts were reviewed to determine the long-term outcomes of those procedures. All patients (n = 56) initially had a PS placed, with or without balloon dilation. However, C-SEMS placement was later attempted in 12 patients because the stricture was refractory to placement of the PS. During their follow-up periods, two patients died of unrelated diseases after 15 and 17 months, and another two still had the C-SEMS in place after 9 and 50 months. In the remaining eight patients, the C-SEMS was removed after a median placement period of 6 months (range, 2-15). Seven patients in this group have not experienced a recurrence at a median follow-up time of 48 months. However, in one patient, stenosis did recur 8 months after the C-SEMS was removed. Temporary placement of C-SEMS can be a treatment option for benign biliary strictures, especially in refractory cases. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  1. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  2. Placement of a Colonic Stent by Percutaneous Colostomy in a Case of Malignant Stenosis

    International Nuclear Information System (INIS)

    Gomez Herrero, Helena; Paul Diaz, Laura; Pinto Pabon, Isabel; Lobato Fernandez, Rosa

    2001-01-01

    We present a patient with disseminated stomach cancer who presented with symptoms of acute obstruction of the splenic flexure of the colon caused by tumor spread. During a first attempt to insert a colon stent through the anus under endoscopic guidance as final palliative therapy, it was not possible to reach the region of the stricture, and iatrogenic perforation of the descending colon occurred, which resolved favorably under conservative management. A second attempt to insert a stent was made via percutaneous puncture of the transverse colon, approaching the region of the stricture by a descending route. The procedure was completed without complications and the patient's symptoms improved. Stent placement via percutaneous puncture of the colon has not previously been described in the literature. It may be an alternate route in cases of proximal strictures in which access through the anus has been unsuccessful even with the aid of endoscopic guidance

  3. Interval biliary stent placement via percutaneous ultrasound guided cholecystostomy: another approach to palliative treatment in malignant biliary tract obstruction.

    Science.gov (United States)

    Harding, James; Mortimer, Alex; Kelly, Michael; Loveday, Eric

    2010-12-01

    Percutaneous cholecystostomy is a minimally invasive procedure for providing gallbladder decompression, often in critically ill patients. It can be used in malignant biliary obstruction following failed endoscopic retrograde cholangiopancreatography when the intrahepatic ducts are not dilated or when stent insertion is not possible via the bile ducts. In properly selected patients, percutaneous cholecystostomy in obstructive jaundice is a simple, safe, and rapid option for biliary decompression, thus avoiding the morbidity and mortality involved with percutaneous transhepatic biliary stenting. Subsequent use of a percutaneous cholecystostomy for definitive biliary stent placement is an attractive concept and leaves patients with no external drain. To the best of our knowledge, it has only been described on three previous occasions in the published literature, on each occasion forced by surgical or technical considerations. Traditionally, anatomic/technical considerations and the risk of bile leak have precluded such an approach, but improvements in catheter design and manufacture may now make it more feasible. We report a case of successful interval metal stent placement via percutaneous cholecystostomy which was preplanned and achieved excellent palliation for the patient. The pros and cons of the procedure and approach are discussed.

  4. Interval Biliary Stent Placement Via Percutaneous Ultrasound Guided Cholecystostomy: Another Approach to Palliative Treatment in Malignant Biliary Tract Obstruction

    International Nuclear Information System (INIS)

    Harding, James; Mortimer, Alex; Kelly, Michael; Loveday, Eric

    2010-01-01

    Percutaneous cholecystostomy is a minimally invasive procedure for providing gallbladder decompression, often in critically ill patients. It can be used in malignant biliary obstruction following failed endoscopic retrograde cholangiopancreatography when the intrahepatic ducts are not dilated or when stent insertion is not possible via the bile ducts. In properly selected patients, percutaneous cholecystostomy in obstructive jaundice is a simple, safe, and rapid option for biliary decompression, thus avoiding the morbidity and mortality involved with percutaneous transhepatic biliary stenting. Subsequent use of a percutaneous cholecystostomy for definitive biliary stent placement is an attractive concept and leaves patients with no external drain. To the best of our knowledge, it has only been described on three previous occasions in the published literature, on each occasion forced by surgical or technical considerations. Traditionally, anatomic/technical considerations and the risk of bile leak have precluded such an approach, but improvements in catheter design and manufacture may now make it more feasible. We report a case of successful interval metal stent placement via percutaneous cholecystostomy which was preplanned and achieved excellent palliation for the patient. The pros and cons of the procedure and approach are discussed.

  5. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  6. The Effect of Ureteral Stent Placement Before Radical Prostatectomy on the Safety of Ureteral Dissection and the Surgeon’s Comfort

    Directory of Open Access Journals (Sweden)

    Fatih Akdemir

    2017-09-01

    Full Text Available Objective: This study investigated the role of preoperative ureteral stent placement in reducing the risk of ureteral injury, an intraoperative complication of radical retropubic prostatectomy (RRP, and its contribution to the surgeon’s comfort. Materials and Methods: Open RRP was performed in 66 patients diagnosed with localized prostate cancer in our clinic between 2010 and 2015. The patients were divided into two groups; group 1 (n=34 underwent surgery without ureteral stent placement and group 2 (n=32 had surgery following the placement of a ureteral stent. The cases were preoperatively evaluated by suprapubic and transrectal ultrasonography. Perioperative and postoperative complications of all cases were determined. Both groups were assessed in terms of ureteral injury, operative time, and surgeon’s comfort. Results: The mean age of the patients in group 1 and group 2 was 61.12±5.92 (50-72 years and 63.58±6.2 (51-75 years, respectively. The mean prostate volume was 76.8±2.41 and 72.4±3.53 cc in groups 1 and 2, respectively. The mean operative time was 143.9±3.06 minutes in group 1 and 136.8±2.83 minutes in group 2. Partial ureteral injury occurred in three patients in group 1 and was repaired intraoperatively. Of these patients, two had previously undergone radiotherapy for prostate cancer and it was difficult to perform prostate dissection intraoperatively. The remaining patient had a history of transurethral resection of the prostate. No ureteral injury was observed in any of the patients in group 2. Conclusion: Preoperative ureteral stent placement in selected patients can facilitate ureteral dissection and reduce ureteral injury risk.

  7. Effectiveness of percutaneous metal stent placement in cholangiocarcinoma patients with midterm follow-up: Single center experience

    International Nuclear Information System (INIS)

    Kose, Fatih; Oguzkurt, Levent; Besen, Ayberk; Sumbul, Taner; Sezer, Ahmet; Karadeniz, Cemile; Disel, Umut; Mertsoylu, Huseyin; Ozyilkan, Ozgur

    2012-01-01

    Purpose: Patients with advanced cholangiocarcinoma present with high rate of local complications. The primary aim of this study is to report clinical course of advanced cholangiocarcinoma patients those who were presented with biliary obstruction and treated with percutaneous biliary stenting. Material and methods: Patients with unresectable locally advanced or metastatic cholangiocarcinoma followed by our center for a period of 4 years were analyzed. For statistical analysis demographic and clinical characteristics of patients, primary biliary drainage method, metal stent occlusion rate, time to stent occlusion, and overall survival rates were recorded. Results: A total of 34 eligible patients were analyzed. 27 patients had metal stent placement. These 27 patients formed the basis of this study. Median overall survival (OS) was 6.0 months. After metal stent deployment bilurubin levels were normalized within a mean of 10 days. During the follow-up period, 13 patients were experienced metal stent occlusion. Median TtSO was 10 weeks. Cytotoxic chemotherapy was administered to 14 (52%) patients. Patients without stent dysfunction had significantly higher rate of chemotherapy exposure rate (p = 0.021). Statistical analysis, however, failed to exhibit significant effect of stent dysfunction on OS. Conclusion: In advanced cholangiocarcinoma, relief of bile duct obstruction is an important part of the initial patient management. This study therefore described the clinical value of percutaneous metal stent in cholangiocarcinoma patients and raises the question about patency of metal stent in cholangiocarcinoma whether we can expect success similar to the success achieved in pancreas carcinoma.

  8. Effectiveness of percutaneous metal stent placement in cholangiocarcinoma patients with midterm follow-up: Single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Kose, Fatih, E-mail: fatihkose@gmail.com [Baskent University Faculty of Medicine, Department of Medical Oncology, Adana (Turkey); Oguzkurt, Levent [Department of Interventional Radiology, Adana (Turkey); Besen, Ayberk; Sumbul, Taner; Sezer, Ahmet; Karadeniz, Cemile; Disel, Umut; Mertsoylu, Huseyin; Ozyilkan, Ozgur [Baskent University Faculty of Medicine, Department of Medical Oncology, Adana (Turkey)

    2012-08-15

    Purpose: Patients with advanced cholangiocarcinoma present with high rate of local complications. The primary aim of this study is to report clinical course of advanced cholangiocarcinoma patients those who were presented with biliary obstruction and treated with percutaneous biliary stenting. Material and methods: Patients with unresectable locally advanced or metastatic cholangiocarcinoma followed by our center for a period of 4 years were analyzed. For statistical analysis demographic and clinical characteristics of patients, primary biliary drainage method, metal stent occlusion rate, time to stent occlusion, and overall survival rates were recorded. Results: A total of 34 eligible patients were analyzed. 27 patients had metal stent placement. These 27 patients formed the basis of this study. Median overall survival (OS) was 6.0 months. After metal stent deployment bilurubin levels were normalized within a mean of 10 days. During the follow-up period, 13 patients were experienced metal stent occlusion. Median TtSO was 10 weeks. Cytotoxic chemotherapy was administered to 14 (52%) patients. Patients without stent dysfunction had significantly higher rate of chemotherapy exposure rate (p = 0.021). Statistical analysis, however, failed to exhibit significant effect of stent dysfunction on OS. Conclusion: In advanced cholangiocarcinoma, relief of bile duct obstruction is an important part of the initial patient management. This study therefore described the clinical value of percutaneous metal stent in cholangiocarcinoma patients and raises the question about patency of metal stent in cholangiocarcinoma whether we can expect success similar to the success achieved in pancreas carcinoma.

  9. Contralateral Deep Vein Thrombosis after Iliac Vein Stent Placement in Patients with May-Thurner Syndrome.

    Science.gov (United States)

    Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu

    2018-04-25

    To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  10. Gianturco-Rösch Z stents in tracheobronchial stenoses.

    Science.gov (United States)

    Petersen, B D; Uchida, B T; Barton, R E; Keller, F S; Rösch, J

    1995-01-01

    To evaluate expandable metallic Gianturco-Rösch Z (GRZ) stents for treatment of benign and malignant tracheobronchial stenoses. Six patients, ages 45-73 years, were treated for severe dyspnea with placement of GRZ stents. Three patients had benign tracheal lesions (one tracheomalacia, two postoperative) and received uncovered GRZ stents. Three patients had malignant stenoses at the level of the carina; one received an uncovered stent and the other two received silicone-covered GRZ stents. Two patients with benign lesions responded well to stent placement. One was asymptomatic for a year and then was lost to follow-up; the other improved substantially but died of end-stage lung disease 5 months after stent placement. A third patient with a benign high tracheal lesion did poorly; symptoms recurred secondary to inferior migration of a stent, which was removed surgically at 4 months. All patients with malignant lesions improved symptomatically after stent placement and remained without significant dyspnea until death (from 1 to 6 months). Expandable GRZ stents are promising devices for treatment of benign lesions and offer effective palliation of malignant tracheobronchial stenoses.

  11. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  12. Ultraflex precision colonic stent placement as a bridge to surgery in patients with malignant colon obstruction

    DEFF Research Database (Denmark)

    Fregonese, D.; Naspetti, R.; Ferrer, S.

    2008-01-01

    Background: Emergency surgery for malignant colon obstruction entails relatively high morbidity and mortality rates and typically necessitates a 2-step resection. These problems might be potentially mitigated by placement of a self-expanding metal stent (SEMS) as a bridge to surgery. A nitinol co...

  13. Simulative study on dose distribution of 103Pd stent in blood-vessel

    International Nuclear Information System (INIS)

    Yuan Shuyu; Dai Guangfu; Xu Zhiyong; Sun Fuyin; Xu Shuhe; Ma Fengwu

    2003-01-01

    Objective: To evaluate the dose distribution of 103 Pd stent in the blood-vessel. Methods: Simulative study on dose distribution of endovascular 103 Pd stent was conducted with thermoluminescence dosimeter. The vessel wall was substituted by muscle equivalent material in this simulative study. Results: When radioactivity of the study 103 Pd stent was 9.8 MBq the absorbed dose from the stent surface by muscle equivalent material was 9.8 Gy at 17 d (the half-life period of 103 Pd). The radioactivity of 103 Pd stent surface rapidly attenuated over the radial distance. 80% of the radioactivity at the area that was radially 0.4 mm apart from the stent surface was absorbed by the simulative blood-vessel wall. Conclusion: Endovascular 103 Pd stent does not exert significant injury on the surrounding organs or tissues

  14. Endotracheal expandable metallic stent placement in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, S; Tanabe, Y; Fujiwara, Y; Koyama, T; Tanigawa, N; Kobayashi, M; Katsube, Y; Nakamura, H [Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology

    1991-01-01

    Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).

  15. Single-step simultaneous side-by-side placement of a self-expandable metallic stent with a 6-Fr delivery system for unresectable malignant hilar biliary obstruction: a feasibility study.

    Science.gov (United States)

    Kawakubo, Kazumichi; Kawakami, Hiroshi; Kuwatani, Masaki; Kudo, Taiki; Abe, Yoko; Kawahata, Shuhei; Kubo, Kimitoshi; Kubota, Yoshimasa; Sakamoto, Naoya

    2015-02-01

    Bilateral self-expandable metallic stent (SEMS) placement for the management of unresectable malignant hilar biliary obstruction (UMHBO) is technically challenging to perform using the existing metallic stents with thick delivery systems. The recently developed 6-Fr delivery systems could facilitate a single-step simultaneous side-by-side placement through the accessory channel of the duodenoscope. The aim of this study was to evaluate the feasibility of this procedure. Between May and September 2013, 13 consecutive patients with UMHBO underwent a single-step simultaneous side-by-side placement of SEMS with the 6-Fr delivery system. The technical success rate, stent patency, and rate of complications were evaluated from the prospectively collected database. Technical success was achieved in 11 (84.6%, 95% confidence interval [CI]: 57.8-95.8) patients. The median procedure time was 25 min. Early and late complications were observed in 23% (one segmental cholangitis and two liver abscesses) and 15% (one segmental cholangitis and one cholecystitis) patients, respectively. Median dysfunction free patency was 263 days (95% CI: 37-263). Five patients (38%) experienced stent occlusion that was successfully managed by endoscopic stent placement. A single-step simultaneous side-by-side placement of SEMS with a 6-Fr delivery system was feasible for the management of UMHBO. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  16. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  17. Self-expandable metal stent placement for the palliation of malignant gastroduodenal obstruction: experience in a large, single, UK centre

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, A.S. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom)]. E-mail: andy.lowe@bradfordhospitals.nhs.uk; Beckett, C.G. [Department of Gastroenterology, Bradford Royal Infirmary (United Kingdom); Jowett, S. [Department of Gastroenterology, Bradford Royal Infirmary (United Kingdom); May, J. [Department of Surgery, Bradford Royal Infirmary (United Kingdom); Stephenson, S. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom); Scally, A. [School of Health Studies, Bradford (United Kingdom); Tam, E. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom); Kay, C.L. [Department of Clinical Radiology, Bradford Royal Infirmary (United Kingdom)

    2007-08-15

    Aim: To assess the technical success rate, and evaluate the clinical outcome, length of hospital stay, and cost of palliative gastro-duodenal stenting in a single-centre. Materials and methods: Eight-seven patients referred for insertion of a gastroduodenal stent between April 1999 and April 2004 were recruited to a non-randomized, before and after intervention study performed in a single centre. Demographic data, diagnosis and symptoms along with clinical and technical outcomes were recorded. Results: The technical success rate was 84/87 (96.6%), with inability to traverse the stricture in three patients. No immediate complications were demonstrated. There was marked improvement after stent placement with resolution of symptoms and commencement of dietary intake in 76 patients (87%). Stenting resulted in improved quality of life as reflected by an increase in Karnofsky score from 44/100, to 63/100 post-procedure. Late complications included perforation (n = 1), migration (n = 1) and stent occlusions due to tumour ingrowth/overgrowth (n = 7; mean 165 days). Mean survival was 107 days (range 0-411 days). Median hospital stay post-stent placement was 5.5 days (range 1-55 days) with a majority of patients (75%) discharged home. The mean cost of each treatment episode was Pounds 4146 ($7132 $US, Euro 6,028 EUROS). Conclusion: The present series confirms that combined endoscopic and radiological gastroduodenal stenting is a highly favourable treatment for patients with inoperable malignant gastric outlet obstruction. The results suggest that this minimally invasive procedure has a very high technical success rate, whilst at the same time providing excellent palliation of symptoms with improved quality of life in the majority of patients.

  18. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  19. A novel self-expanding fully retrievable intracranial stent (SOLO): experience in nine procedures of stent-assisted aneurysm coil occlusion

    International Nuclear Information System (INIS)

    Liebig, Thomas; Henkes, Hans; Reinartz, Joerg; Miloslavski, Elina; Kuehne, Dietmar

    2006-01-01

    The endovascular treatment of large and broad-necked aneurysms may require the use of a remodelling balloon or a stent system to achieve proper occlusion while maintaining the patency of the parent vessel. With the advent of self-expanding stents that can be delivered through a microcatheter, this kind of treatment has improved and problems with the previously used balloon expandable stents have largely been overcome. However, rigidity, insufficient trackability, and limited or non-existent retrievability may still restrict the application of self-expanding stents in some situations. Recently, a stent system with a new and different design has been introduced. This stent is highly flexible, fully retrievable, and can be delivered through a standard 0.021-inch microcatheter without a wire. We describe the first nine cases of stent-assisted coil occlusion of intracranial aneurysms with the use of this stent system. Between May and June of 2004, nine patients with large or broad-necked aneurysms were treated in two endovascular centres. The anatomy of the aneurysms and parent vessels, technical details of the procedure, performance of the stent system, and follow-up results were evaluated. In all procedures, the SOLO stent could be introduced without difficulty, in one procedure after positioning of a different self-expanding stent system had failed due to vessel tortuosity. Overlapping stents were placed in one patient and stent retrieval or repositioning was successfully performed in two procedures. There was no interference or limitation of subsequent coil occlusion after stenting. With regard to the stent, immediate postprocedure and follow-up angiograms were unremarkable in terms of thromboembolic events and signs of intimal hyperplasia. From our experience, we conclude that the SOLO stent shows satisfactory performance overall. Its unique design gives the stent properties that may help overcome some of the difficulties experienced with other self

  20. Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature

    NARCIS (Netherlands)

    van Halsema, Emo E.; van Hooft, Jeanin E.

    2015-01-01

    AIM: To analyze the outcomes of self-expandable stent placement for benign esophageal strictures and benign esophageal leaks in the literature. METHODS: The PubMed, Embase and Cochrane databases were searched for relevant articles published between January 2000 and July 2014. Eight prospective

  1. Self-expandable nitinol stent placement in homocysteinemic porcine aorta

    Directory of Open Access Journals (Sweden)

    Luís Henrique Gil França

    2008-01-01

    Full Text Available PURPOSE: To compare aortic intimal thickening of normal and hyperhomocysteinemic pigs (induced with a methionine-rich diet following placement of a self-expanding nitinol stent. METHODS: Eighteen Macau pigs were used. They were older than eight weeks in age and had an average weight of 30 kg. Pigs were randomly divided into two groups. The first, Group C (control, was fed a regular diet, and the second group, Group M, was fed a methionine-rich diet for 30 days to induce hyperhomocysteinemia. The self-expandable nitinol stents were 25mm in length and 8 mm in diameter after expansion. Blood samples were collected to measure total cholesterol, triglycerides, HDL and homocysteine concentrations. All animals were subjected to angiography. Thirty days after the procedure, the animals were sacrificed, and the abdominal aorta was removed for histological and digital morphometry analysis. RESULTS: Under microscopic evaluation, the intima was significantly thicker in Group C than in Group M. When groups were compared by digital morphometric analysis, intimal thickening of the vessel wall was higher in Group C than in Group M. There was no significant change in total cholesterol, triglycerides or HDL concentrations in either group. In group C the levels of plasma homocysteine ranged from 14,40 to 16,73µmol/l; in Group M, plasma homocysteine levels ranged from 17.47 to 59.80 µmol/l after 30 days of a methionine-rich diet. CONCLUSION: Compared to normal pigs, less intimal hyperplasia was observed in the abdominal aortas of hyperhomocysteinemic pigs thirty days after the insertion of a self-expandable nitinol stent.

  2. Stent tunnel technique to save thrombosed native hemodialysis fistula with extensive venous aneurysm

    Directory of Open Access Journals (Sweden)

    Rabellino M

    2017-07-01

    Full Text Available Martin Rabellino,1 Guillermo J Rosa-Diez,2 Sergio A Shinzato,1 Pablo Rodriguez,1 Oscar A Peralta,1 Maria S Crucelegui,2 Rosario Luxardo,2 Agustina Heredia-Martinez,2 Mariela I Bedini-Rocca,2 Ricardo D García-Mónaco1 1Department of Angiography and Endovascular Therapy, 2Department of Nephrology, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina Introduction and purpose: The increasing number of patients undergoing hemodialysis and the limited number of access sites have resulted in an increasing number of techniques to maintain vascular access for hemodialysis. Thrombosed arteriovenous (AV fistulas with large venous aneurysms have poor treatment results, with both endovascular and surgical techniques, leading to a high rate of definitive AV access loss. The purpose of this study was to review the feasibility and initial results of this novel endovascular treatment of thrombosed AV fistulas with large venous aneurysms.Materials and methods: A novel endovascular treatment technique of inserting nitinol auto-expandable uncovered stents stretching through the whole puncture site area, thus creating a tunnel inside the thrombus, was retrospectively analyzed and described.Results: A total of 17 stents were placed in 10 hemodialysis fistulas, with a mean venous coverage length of 17.8 cm. In all the cases, 100% technical success was achieved, with complete restoration of blood flow in all patients. There were no procedure-related complications. The mean follow-up was 167 days (range 60–420 days, with a primary and assisted patency of 80% and 100%, respectively. No multiple trans-stent struts-related complications were observed. Three stent fractures were diagnosed with plain films at the site of puncture without consequence in the venous access permeability.Conclusion: The “stent tunnel technique” is a feasible, safe and effective alternative to salvage native hemodialysis access, thus extending the function of the venous access with

  3. Endovascular Treatment of Chronic Mesenteric Ischemia: Results in 14 Patients

    International Nuclear Information System (INIS)

    Chahid, Tamam; Alfidja, Agaicha T.; Biard, Marie; Ravel, Anne; Garcier, Jean Marc; Boyer, L.

    2004-01-01

    We evaluated immediate and long-term results of percutaneous transluminal angioplasty (PTA) and stent placement to treat stenotic and occluded arteries in patients with chronic mesenteric ischemia. Fourteen patients were treated by 3 exclusive celiac artery (CA) PTAs (2 stentings), 3 cases with both Superior Mesenteric Artery (SMA) and CA angioplasties, and 8 exclusive SMA angioplasties (3 stentings). Eleven patients had atheromatous stenoses with one case of an early onset atheroma in an HIV patient with antiphospholipid syndrome. The other etiologies of mesenteric arterial lesions were Takayashu arteritis (2 cases) and a postradiation stenoses (1 case). Technical success was achieved in all cases. Two major complications were observed: one hematoma and one false aneurysm occurring at the brachial puncture site (14.3%). An immediate clinical success was obtained in all patients. During a follow-up of 1-83 months (mean: 29 months), 11 patients were symptom free; 3 patients had recurrent pain; in one patient with inflammatory syndrome, pain relief was obtained with medical treatment; in 2 patients abdominal pain was due to restenosis 36 and 6 months after PTA, respectively. Restenosis was treated by PTA (postirradiation stenosis), and by surgical bypass (atheromatous stenosis). Percutaneous endovascular techniques are safe and accurate. They are an alternative to surgery in patients with chronic mesenteric ischemia due to short and proximal occlusive lesions of SMA and CA

  4. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  5. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  6. Future developments in biliary stenting

    Science.gov (United States)

    Hair, Clark D; Sejpal, Divyesh V

    2013-01-01

    Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting. PMID:23837001

  7. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    Science.gov (United States)

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  8. The risk of endoleak following stent covering of the internal iliac artery during endovascular aneurysm repair

    International Nuclear Information System (INIS)

    Rajesparan, K.; Partridge, W.; Refson, J.; Abidia, A.; Aldin, Z.

    2014-01-01

    Aim: To investigate the risk of endoleak during endovascular aneurysm repair (EVAR) involving the distal common iliac artery (CIA) when the internal iliac artery (IIA) is covered without prior coil embolization. Materials and methods: Retrospective analysis of 145 (125 men, 20 women) consecutive EVAR cases. Clinical notes and radiological images were reviewed, and data collected on patient demographics, aneurysm morphology, covering of the IIA with or without embolization, presence of endoleaks, and patient symptoms relating to IIA ischaemia. Results: A total of 29 IIAs (10%) were covered in a total of 25 patients. Seven IIAs (24%) were embolized before stent covering (Embolization group), and 22 IIAs (76%) were covered only without embolization (Cover group). There was no statistically significant difference in the mean size of the abdominal aortic aneurysm diameter or CIA diameter between each group. No endoleaks from IIA retrograde filling were found in either group. Conclusion: The results of the present study do not support the traditional view that coverage of the IIA without prior embolization carries a high risk of endoleak, with no endoleaks seen in all 22 cases. Large-scale trials are required. However, the advent of branched-stenting techniques and the emergence of their success in long-term follow-up may preclude the former. - Highlights: • No EVAR endoleaks due to retrograde filling of the internal iliac artery (IIA). • No increased risk of endoleak with stent coverage of the IIA without embolisation. • Current evidence does not support traditional views

  9. Covered metal stent or multiple plastic stents for refractory pancreatic ductal strictures in chronic pancreatitis: a systematic review.

    Science.gov (United States)

    Shen, Yonghua; Liu, Mingdong; Chen, Min; Li, Yunhong; Lu, Ying; Zou, Xiaoping

    2014-01-01

    Refractory chronic pancreatitis has been proposed as a challenge for endoscopists following routine single plastic stenting. However, data on the efficacy and safety of further endoscopic stenting are still controversial. The current systematic review aimed to assess the efficacy and safety of placement of fully covered self-expandable metal stent (FCSEMS) and multiple plastic stents. Databases including MEDLINE, EMBASE, the Cochrane Library, CBM, CNKI, VIP, and WANFANG Database were used to search relevant trials. Published studies were assessed by using well-defined inclusion and exclusion criteria. The process was independently performed by two investigators. A total of 5 studies provided data of 80 patients. Forest plots and publication bias were not carried out because few studies were relevant and screened studies were all case series. The technical success rate was 100% both in placement of FCSEMS and multiple plastic stents. The functional success rate after placement of FCSEMS was 100%, followed by multiple plastic stents (94.7%). Complications occurred 26.2% after FCSEMS placement, which was not described in detail in multiple plastic stents. The stent migration rate was 8.2% for FCSEMS and 10.5% for multiple plastic stents. Reintervention rate was 9.8% for FCSEMS and 15.8% for multiple plastic stents. Pain improvement rate was 85.2% for FCSEMS and 84.2% for multiple plastic stents. FCSEMS appeared to be no significant difference with multiple plastic stents in treatment of refractory chronic pancreatitis. We need to develop more investigations. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  10. Delayed Development of Brain Abscesses Following Stent-Graft Placement in a Head and Neck Cancer Patient Presenting with Carotid Blowout Syndrome

    International Nuclear Information System (INIS)

    Oweis, Yaseen; Gemmete, Joseph J.; Chaudhary, Neeraj; Pandey, Aditya; Ansari, Sameer

    2011-01-01

    We describe the delayed development of intracranial abscesses following emergent treatment with a covered stent-graft for carotid blowout syndrome (CBS) in a patient with head and neck cancer. The patient presented with hemoptysis and frank arterial bleeding through the tracheostomy site. A self-expandable stent-graft was deployed across a small pseudoaneurysm arising from the right common carotid artery (RCCA) and resulted in immediate hemostasis. Three months later, the patient suffered a recurrent hemorrhage. CT of the neck demonstrated periluminal fluid around the caudal aspect of the stent-graft with intraluminal thrombus and a small pseudoaneurysm. Subsequently, the patient underwent a balloon test occlusion study and endovascular sacrifice of the RCCA and right internal carotid artery. MRI of the brain demonstrated at least four ring-enhancing lesions within the right cerebral hemisphere consistent with intracranial abscesses that resolved with broad-spectrum antibiotic coverage.

  11. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  12. Evaluation of the Effects of Temporary Covered Nitinol Stent Placement in the Prostatic Urethra: Short-Term Study in the Canine Model

    International Nuclear Information System (INIS)

    Crisostomo, Veronica; Song, Ho Young; Maynar, Manuel; Sun, Fei; Soria, Federico; Lima, Juan Rafael; Yoon, Chang Jin; Uson-Gargallo, Jesus

    2007-01-01

    Purpose. To evaluate the effect of temporary stent placement on the canine prostatic urethra. Methods. Retrievable PTFE-covered nitinol stents were placed in the prostatic urethras of 8 beagle dogs under fluoroscopic guidance. Retrograde urethrography was obtained before and after stenting. Retrograde urethrography and endoscopy were performed 1 and 2 months after deployment. The endoscopic degree of hyperplasia was rated on a scale of 0 to 4 (0 absence, 4 = occlusion). On day 60, stents were removed and urethrography was performed immediately before euthanasia. Pathologic analysis was performed to determine the degree of glandular atrophy, periurethral fibrosis, and urethral dilation. Results. Stent deployment was technically successful in 7 animals, and failed in 1 dog due to a narrow urethral lumen. Complete migration was seen in 2 animals at 1 month, and an additional stent was deployed. On day 30, endoscopy showed slight hyperplasia (grade 1) in 3 animals. On day 60, moderate hyperplasia (grade 2) was evidenced in 4 cases. No impairment of urinary flow was seen during follow-up. Retrieval was technically easy to perform, and was successful in all dogs. The major histologic findings were chronic inflammatory cell infiltrates; prostate glandular atrophy, with a mean value of 1.86 (SD 0.90); periurethral fibrosis, with a mean ratio of 29.37 (SD 10.41); and dilatation of the prostatic urethra, with a mean ratio of 6.75 (SD 3.22). Conclusion. Temporary prostatic stent placement in dogs is safe and feasible, causing marked enlargement of the prostatic urethral lumen. Retrievable covered stents may therefore be an option for bladder outlet obstruction management in men

  13. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Esch, Jan Schulte am; Hammerschlag, Sascha; Knoefel, Wolfram Trudo; Fuerst, Guenter

    2008-01-01

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  14. Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Sedat, Jacques; Chau, Yves; Mondot, Lydiane [CHU Nice, Unite de Neurointerventionnelle, Hopital St. Roch, Nice (France); Vargas, Julian; Szapiro, Jacek; Lonjon, Michel [CH Bastia, Service de Neurochirurgie, Bastia (France)

    2009-06-15

    Coiling associated with placement of self-expandable intracranial stents has amplified the treatment of intracranial wide-necked aneurysms, but the durability of this treatment and the existence of delayed recurrence are not yet well known. The purpose of this report is to present our experience with the Neuroform Stent associated with coiling and to evaluate complications, effectiveness, and long-term results of this technique. A retrospective study of 42 patients with wide-necked cerebral aneurysms treated with the Neuroform Stent was performed. Mean aneurysm size was 11.3 mm. Mean neck size was 5.33 mm. All patients were treated with coiling and stenting. Clinical and angiographic follow-up was available in 38 patients (90.5%). The overall follow-up time ranged from 6 months to 5 years (mean, 42 months), but most of the patients (92%) had a follow-up period superior to 1 year. Successful deployment of 41 stents (97%) was obtained. Permanent procedural morbidity was observed in only one patient (2.4%). Long-term complete aneurysmal occlusion was obtained in 27 patients (71%). Aneurysmal regrowth was observed in four patients (9.5%) on the first control angiogram. After the first control angiogram, no delayed recanalization or regrowth was observed. During the follow-up period, there were no hemorrhagic events, no delayed thrombosis, and no stent displacement. Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year. (orig.)

  15. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    International Nuclear Information System (INIS)

    De Cock, Erwin; Sapoval, Marc; Julia, Pierre; Lissovoy, Greg de; Lopes, Sandra

    2013-01-01

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of €6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  16. A Budget Impact Model for Paclitaxel-eluting Stent in Femoropopliteal Disease in France

    Energy Technology Data Exchange (ETDEWEB)

    De Cock, Erwin, E-mail: erwin.decock@unitedbiosource.com [United BioSource Corporation, Peri- and Post-Approval Services (Spain); Sapoval, Marc, E-mail: Marc.sapoval2@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Department of Cardiovascular and Interventional Radiology (France); Julia, Pierre, E-mail: pierre.julia@egp.aphp.fr [Hopital Europeen Georges Pompidou, Universite Rene Descartes, Cardiovascular Surgery Department (France); Lissovoy, Greg de, E-mail: gdelisso@jhsph.edu [Johns Hopkins Bloomberg School of Public Health, Department of Health Policy and Management (United States); Lopes, Sandra, E-mail: Sandra.Lopes@CookMedical.com [Cook Medical, Health Economics and Reimbursement (Denmark)

    2013-04-15

    The Zilver PTX drug-eluting stent (Cook Ireland Ltd., Limerick, Ireland) represents an advance in endovascular treatments for atherosclerotic superficial femoral artery (SFA) disease. Clinical data demonstrate improved clinical outcomes compared to bare-metal stents (BMS). This analysis assessed the likely impact on the French public health care budget of introducing reimbursement for the Zilver PTX stent. A model was developed in Microsoft Excel to estimate the impact of a progressive transition from BMS to Zilver PTX over a 5-year horizon. The number of patients undergoing SFA stenting was estimated on the basis of hospital episode data. The analysis from the payer perspective used French reimbursement tariffs. Target lesion revascularization (TLR) after primary stent placement was the primary outcome. TLR rates were based on 2-year data from the Zilver PTX single-arm study (6 and 9 %) and BMS rates reported in the literature (average 16 and 22 %) and extrapolated to 5 years. Net budget impact was expressed as the difference in total costs (primary stenting and reinterventions) for a scenario where BMS is progressively replaced by Zilver PTX compared to a scenario of BMS only. The model estimated a net cumulative 5-year budget reduction of Euro-Sign 6,807,202 for a projected population of 82,316 patients (21,361 receiving Zilver PTX). Base case results were confirmed in sensitivity analyses. Adoption of Zilver PTX could lead to important savings for the French public health care payer. Despite higher initial reimbursement for the Zilver PTX stent, fewer expected SFA reinterventions after the primary stenting procedure result in net savings.

  17. Transarterial endovascular treatment in the management of life-threatening carotid blowout syndrome in head and neck cancer patients: review of the literature.

    Science.gov (United States)

    Dequanter, D; Shahla, M; Paulus, P; Aubert, C; Lothaire, P

    2013-12-01

    Carotid blowout syndrome is a rare but devastating complication in patients with head and neck malignancy, and is associated with high morbidity and mortality. Bleeding from the carotid artery or its branches is a well-recognized complication following treatment or recurrence of head and neck cancer. It is an emergency situation, and the classical approach to save the patient's life is to ligate the carotid artery. But the surgical treatment is often technically difficult. Endovascular therapies were recently reported as good alternatives to surgical ligation. Retrospective review of three cases of acute or threatened carotid hemorrhage managed by endovascular therapies. Two patients presented with acute carotid blowout, and one patient with a sentinel bleed. Two patients had previously been treated with surgery and chemo radiation. One patient was treated by chemo radiation. Two had developed pharyngocutaneous fistulas, and one had an open necrosis filled wound that surrounded the carotid artery. In two patients, stent placement resolved the acute hemorrhage. In one patient, superselective embolization was done. Mean duration follow-up was 10.2 months. No patient had residual sequelae of stenting or embolization. Management of carotid blow syndrome is very critical and difficult. A multidisciplinary approach is very important in the management of carotid blow syndrome. Correct and suitable management can be life saving. An endovascular technique is a good and effective alternative with much lower morbidity rates than surgical repair or ligation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Advances in endovascular therapy for ischemic cerebrovascular diseases

    Directory of Open Access Journals (Sweden)

    Jun Lu

    2016-09-01

    Full Text Available Endovascular therapy for ischemic cerebrovascular diseases has developed rapidly in recent years. The latest clinical trials of acute ischemic stroke have shown promising results with the continued advancement of concepts, techniques, and materials. Mechanical thrombectomy is recommended in the treatment of acute ischemic stroke caused by large vessel occlusion of the anterior circulation, according to the guidelines updated in Europe, USA, and China. The long-term therapeutic efficacy of endovascular stenting for carotid artery stenosis has also been proved noninferior to that of carotid endarterectomy. However, the latest clinical trials have shown that the efficacy of stenting for intracranial artery and vertebral artery stenosis is inferior to that of medical treatment alone, which needs urgent attention through further development and studies. Keywords: Ischemic cerebrovascular diseases, Interventional surgery, Progress

  19. Predictors of outcomes in patients undergoing covered and uncovered self-expandable metal stent placement for malignant gastric outlet obstruction: a multicenter study.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-02-01

    Uncovered self-expandable metal stents (U-SEMSs) and covered self-expandable metal stents (C-SEMSs) are available for palliative therapy for malignant gastric outlet obstruction (GOO). However, clinical differences and indications between the 2 types of SEMSs have not been elucidated. We retrospectively compared 126 patients with U-SEMS and 126 patients with C-SEMSs with regard to clinical outcome and factors predictive of clinical improvement after SEMSs placement. No significant difference was observed between the U-SEMS and C-SEMS groups with respect to technical success, clinical success, GOO score, or time to stent dysfunction. Stent migration was significantly more frequent in patients with C-SEMSs (U-SEMSs, .79%; C-SEMSs, 8.73%; P = .005). Karnofsky performance status, chemotherapy, peritoneal dissemination, and stent expansion ≤ 30% were associated significantly with poor GOO score improvement in multivariable analyses, but stent type was not (P = .213). In subgroup analyses, insufficient (≤30%) stent expansion was an independent factor in patients with U-SEMSs (P = .041) but not C-SEMSs. In the insufficient stent expansion subgroup, C-SEMSs was associated significantly with superior clinical improvement compared with U-SEMSs (P = .01). Insufficient stent expansion was observed more frequently in patients with GI obstruction because of anastomotic sites or metastatic cancer (44.8% [13/29], P = .001). No clinical difference, apart from stent migration, was observed between patients with U-SEMSs and C-SEMSs. GI obstruction because of an anastomotic site or metastatic cancer may be an indication for C-SEMS use to improve oral intake after SEMSs placement. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Hemodynamic comparison of stent configurations used for aortoiliac occlusive disease

    NARCIS (Netherlands)

    Groot Jebbink, Erik; Mathai, Varghese; Boersen, Johannes Thomas; Sun, Chao; Slump, Cornelis H.; Goverde, Peter C.J.M.; Versluis, Michel; Reijnen, Michel M.P.J.

    Background Endovascular treatment of aortoiliac occlusive disease entails the use of multiple stents to reconstruct the aortic bifurcation. Different configurations have been applied and geometric variations exist, as quantified in previous work. Other studies concluded that specific stent geometry

  1. Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies

    International Nuclear Information System (INIS)

    Pitton, M. B.; Herber, S.; Schmiedt, W.; Neufang, A.; Dorweiler, B.; Dueber, C.

    2008-01-01

    Purpose. To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods. From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 ± 19.2 years, range 18-85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results. A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed-for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure-resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 ± 36.6 months (range 0-139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a

  2. [Endovascular surgery in the war].

    Science.gov (United States)

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  3. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. The use of balloon-expandable metallic stents in the treatment of pediatric tracheomalacia and bronchomalacia.

    Science.gov (United States)

    Furman, R H; Backer, C L; Dunham, M E; Donaldson, J; Mavroudis, C; Holinger, L D

    1999-02-01

    To evaluate the use of balloon-expandable metallic stents in the treatment of children with tracheomalacia and bronchomalacia in whom conventional therapy has failed. Retrospective case series. Tertiary pediatric otolaryngology and cardiothoracic surgery referral center. Six patients were identified as having undergone bronchoscopic placement of metallic balloon-expandable stents between 1994 and 1997. The age at stent placement, prior surgical interventions, and indications for and sites of stent placement were noted. Also, the complications related to stent placement and the current airway status of the patients were reviewed. Twelve balloon-expandable metallic angioplasty stents (Palmaz; Johnson & Johnson Interventional Systems Co, Warren, NJ) were placed bronchoscopically in 6 patients. Six stents were placed in the lower trachea, and 6 were placed in the main bronchi. The stents were balloon expanded under fluoroscopic guidance. Discontinuation of mechanical ventilation. The age at stent placement ranged from 1.5 to 38 months (mean age at placement, 10 months). The indications for stent placement were (1) tracheomalacia or bronchomalacia, (2) pericardial patch or slide tracheoplasty failure, and (3) bronchomalacia caused by tetralogy of Fallot and large pulmonary arteries. The primary complication of stent placement was postoperative granulation tissue formation. One patient required the removal of 2 tracheal stents because of granulation tissue formation. There were 2 deaths in the series, 1 possibly related to stent placement. Four of the 6 patients were weaned from mechanical ventilation, and 3 experienced prolonged relief of airway obstruction. Metallic balloon-expandable stents are effective in relieving lower tracheomalacia and bronchomalacia in select patients. Only patients in whom conventional therapy has failed should be considered for stent placement.

  5. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  6. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  7. Endovascular surgery in Marfan syndrome: CON.

    Science.gov (United States)

    Kouchoukos, Nicholas T

    2017-11-01

    The frequency of endovascular stent grafting procedures to treat various conditions of the thoracic aorta has increased dramatically over the past three decades. Stent grafting has been applied on a limited basis in patients with Marfan syndrome and other connective tissue disorders, despite recommendations from current guidelines and expert consensus statements against its use in this setting. A review of publications reporting outcomes after stent grafting of the descending thoracic aorta in Marfan patients with acute or chronic aortic dissection indicates that these procedures can be accomplished with rates of early mortality, stroke and spinal cord ischemic injury that are comparable to those observed in patients who do not have Marfan syndrome. However, the rates of primary treatment failure (principally endoleak), secondary treatment failure, need for open repair and late death among the Marfan patients are substantially higher than those observed in patients without this condition. In addition, the rates of retrograde aortic dissection and development of stent-graft induced new entry (SINE), are also greater among patients with Marfan syndrome. All of these findings argue strongly against the routine use of endovascular grafts in Marfan patients with type B or residual type A dissection. Few data are available to assess the role of endografting in Marfan patients with aneurysmal disease, but the progressive aortic dilatation noted in these patients argues strongly against its use in this setting as well. At present, the available data indicate that there is no justification for elective stent grafting in Marfan patients with aortic dissection or aneurysm. The only reasonable indications for primary aortic stent grafting are in the setting of acute aortic dissection or rupture, where the intervention is considered life-saving and rarely, considering the relatively young age of these patients, where the risk of open operation is considered to be prohibitive.

  8. Low-profile stent placement with the monorail technique for treatment of renal artery stenosis: midterm results of a prospective trial.

    Science.gov (United States)

    Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas

    2005-07-01

    To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.

  9. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  10. Removal of self expandable metallic airway stent: A rare case report

    Directory of Open Access Journals (Sweden)

    Rakesh K Chawla

    2013-01-01

    Full Text Available Covered self expandable metallic airway stents (SEMS have been used for benign tracheal stenosis, post intubation tracheal stenosis, tracheal burn or trauma, tracheo-broncho-malacia, and extrinsic compression of trachea. Their placement is considered to be permanent, with open surgery the only way to remove the stent, though there are few cases reports of their removal with the bronchoscope, but the complications after their removal are very high. In our patient, one and a half years after placement of SEMS, she developed cough with dyspnoea, video bronchoscopy showed stenosis above the level of stent with granulation tissue inside the stent, stent fracture in lower part and stent migration to right main bronchus, thus she had all conceivable complications of stent placement. The stent was removed with the help of rigid bronchoscope under general anaesthesia. She was discharged the following day. The case is being reported because it was unique in having all the possible complications of stent placement, and rare as we could take out the stent in Toto. Thirdly, the stent could be removed without any complication.

  11. Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.

    Science.gov (United States)

    Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-05-01

    This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Endovascular Device Testing with Particle Image Velocimetry Enhances Undergraduate Biomedical Engineering Education

    Science.gov (United States)

    Nair, Priya; Ankeny, Casey J.; Ryan, Justin; Okcay, Murat; Frakes, David H.

    2016-01-01

    We investigated the use of a new system, HemoFlow™, which utilizes state of the art technologies such as particle image velocimetry to test endovascular devices as part of an undergraduate biomedical engineering curriculum. Students deployed an endovascular stent into an anatomical model of a cerebral aneurysm and measured intra-aneurysmal flow…

  13. Stent placement or brachytherapy for palliation of dysphagia from esophageal cancer: a prognostic model to guide treatment selection

    NARCIS (Netherlands)

    Steyerberg, Ewout W.; Homs, Marjolein Y. V.; Stokvis, Annemieke; Essink-Bot, Marie-Louise; Siersema, Peter D.

    2005-01-01

    BACKGROUND: Brachytherapy was found to be preferable to metal stent placement for the palliation of dysphagia because of inoperable esophageal cancer in the randomized SIREC trial. The benefit of brachytherapy, however, only occurred after a relatively long survival. The objective is to develop a

  14. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  15. Combined stent placement and high dose PGE1 drip infusion for chronic occlusion of the superficial femoral artery as a modality to salvage chronic critical limb ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Ikushima, Ichiro [Department of Radiology, Miyakonojo Medical Association Hospital, 5822-3 Oiwadacho, Miyakonojo 885-0062 (Japan)], E-mail: iku-i@fk.enjoy.ne.jp; Hirai, Toshinori [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University (Japan); Ishii, Akihiko [Department of Radiology, Miyakonojo Medical Association Hospital, 5822-3 Oiwadacho, Miyakonojo 885-0062 (Japan); Yamashita, Yasuyuki [Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University (Japan)

    2008-04-15

    Purpose: To assess the initial effect, short-term patency, and limb salvage rates of combined stent placement and high-dose prostaglandin E-1 (PGE1) drip infusion for chronic occlusion of the superficial femoral artery (SFA). Materials and methods: A total of 15 arteriosclerotic occlusive lesions of the SFA were treated in 11 consecutive patients (mean age: 78.4 years old). All cases were of category 4 or 5, based on the criteria of the Society of Vascular Surgery and Intermittent Society for Cardiovascular Surgery (SVC/ISCVS). In all cases a self-expandable stainless steel stent was implanted. PGE1 treatment was started 3-5 days before stent placement and continued for 7-10 days after the intervention. The technical success, limb salvage outcomes, patency rates, and complications were examined. Results: In all cases, the technical success rate of the procedure was 100%. After stent implantation, the clinical status of all cases was improved by at least +2, and major amputation was not required in any cases. The 12-month primary, secondary patency rates, and limb salvage rate were 57%, 100%, and 100%, respectively. Conclusion: Combined stent placement and high-dose PGE1 drip infusion is a treatment of choice for salvaging the lower limb of a patient with chronic critical ischemia.

  16. Lesion complexity drives the cost of superficial femoral artery endovascular interventions

    Science.gov (United States)

    Walker, Karen L.; Nolan, Brian W.; Columbo, Jesse A.; Rzucidlo, Eva M.; Goodney, Philip P.; Walsh, Daniel B.; Atkinson, Benjamin J.; Powell, Richard J.

    2017-01-01

    Objective Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. Methods A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. Results During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. Conclusions SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. PMID:26206581

  17. Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection.

    Science.gov (United States)

    Qing, K-X; Chan, Y-C; Ting, A C W; Cheng, S W K

    2016-05-01

    Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  18. Combined stent implantation and embolization with liquid 2-polyhydroxyethyl methacrylate for treatment of experimental canine wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Klisch, J.; Zitt, J.; Schumacher, M. [Section of Neuroradiology, University of Freiburg (Germany); Schellhammer, F. [Department of Radiology, University of Cologne, Cologne (Germany); Scheufler, K.M. [Department of Neurosurgery, University of Freiburg (Germany); Pagenstecher, A. [Department of Neuropathology, University of Freiburg, Freiburg (Germany); Nagursky, H. [Department of Oral and Maxillofacial Surgery, University of Freiburg, Freiburg (Germany)

    2002-06-01

    The purpose of the study was the evaluation of 2-polyhydroxyethyl methacrylate (2-P-HEMA) for endovascular liquid embolization of experimental side-wall aneurysms following stent protection in a canine model. The swelling behaviour and polymerization characteristics of 2-P-HEMA in different solutions were investigated in vitro. Different methods for applications were tested in a latex aneurysm model under pulsatile flow conditions. Twenty broad-based carotid side-wall aneurysms were microsurgically produced in five dogs. Four weeks after surgery self-expandable nitinol stents were placed, covering the orifice of the aneurysms. 2-P-HEMA was injected via a microcatheter, which was positioned through the meshwork of the stent. Control angiography was performed immediately after treatment and after 1, 6 and 9 months. In-vivo stent placement succeeded in all but one case. Two aneurysms occluded spontaneously after stent placement. Combined embolization of 17 aneurysms using a stent and 2-P-HEMA was performed. Eleven aneurysms could be primarily completely occluded (65%). A small remaining neck was evident in six aneurysms. Efflux of 2-P-HEMA during the process of embolization was observed in seven aneurysms, due to an excess volume of 2-P-HEMA. The excessive 2-P-HEMA led to significant vessel stenosis in two cases. Two carotid arteries (three treated aneurysms) occluded after 1 month, due to insufficient anticoagulation management. Histological examination of embolized aneurysms revealed no foreign-body or inflammatory reaction. A smooth neo-intimal layer covered the stented vessel segment. Liquid embolization of side-wall aneurysms with 2-P-HEMA is technically feasible. Embolotherapy of aneurysms with liquid agents still has the risk that embolic material will exit even when it is stent-protected. To avoid this problem, stents with smaller strut diameter and/or additional balloon-protection are required. The inert 2-P-HEMA seems to be a promising agent for combining

  19. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  20. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    International Nuclear Information System (INIS)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah

    2009-01-01

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease

  1. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2009-07-15

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease.

  2. Endobronchial Occlusion Stent: A Preliminary Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yo Won; Jeong, Woo Kyoung; Lee, Seoung Hoon; Heo, Jeong Nam; Jeon, Seok Chol [Hanyang University College of Medicine, Seoul (Korea, Republic of); Ko, Gi Young; Song, Ho Young [University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2010-04-15

    To evaluate the safety and the technical feasibility of the use of an endobronchial occlusion stent and to get preliminary data for the development of the optimal material required for endobronchial occlusions. A commercialized, self-expandable tracheobronchial stent was modified; one half had a polyurethane cover with an occluded end and the other half was uncovered with a flaring configuration. The occluded end was placed such that it would face the distal lung. Under fluoroscopic guidance, seven stents were placed at the lower lobar bronchus in 6 mini-pigs. The bronchial obstruction was examined immediately after stent placement. Chest radiographs were taken at days 1, 7, 14, and 28 after stent placement and the removed airways from two, two, one, and one mini-pigs sacrificed on corresponding days were examined for the maintenance of bronchial obstruction. Stents were successfully placed and induced the immediate bronchial obstruction in all mini-pigs. Five of seven airways with occlusion stents maintained an obstruction until the mini-pigs were sacrificed. Proximal stent migration occurred in two mini-pigs (29%), and pulmonary consolidations were observed distal to four of the stents (57%). The placement of an endobronchial occlusion stent and the obstruction of targeted bronchi seem to be feasible, but an add-on check valve should be considered to prevent stent migration and obstructive pneumonia

  3. Malignant duodenal obstructions: palliative treatment with covered expandable nitinol stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Chul; Jung, Gyoo Sik; Lee, Sang Hee; Kim, Sung Min; Oh, Kyung Seung; Huh, Jin Do; Cho, Young Duk [College of Medicine, Kosin Univ, Pusan (Korea, Republic of); Song, Ho Young [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    2002-04-01

    To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, and after-loading technique was used. Stent placement was technically successful in ten patients, and no procedural complications occuured. In one of two patients in whom there was technical failure, and in whom the obstructions were located in part III, the stent was placed transgastrically. Stent migration occurred in one patient four days after the procedure, and treatment involved the palcement of a second, uncovered, nitinol stent. After stent placement, symptoms improved in all patients. During follow-up, obstructive symptoms due to stent stenosis (n=1), colonic obstruction (n=1), and multiple small bowel obstruction (n=1) recurred in three patients. Two of these were treated by placing additional stents in the duodenum and colon, respectively. One of the eight patients in whom a stent was placed in the second portion of the duodenum developed jaundice. The patients died a mean 14 (median, 9) weeks after stent placement. The placement of a polyurethane-covered expandable nitinol stent seems to be technically feasible, safe and effective for the palliative treatment of malignant

  4. Peri-stent aneurysm formation following a stent implant for stenotic intracranial vertebral artery dissection: a technical report of two cases successfully treated with coil embolization.

    Science.gov (United States)

    Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro

    2013-02-01

    Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.

  5. Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Bandorski, Dirk; Brueck, Martin; Guenther, Hans-Ulrich; Manke, Christoph

    2010-01-01

    Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16 patients with a thoracic endograft between 2001 and 2006. Medical records of the treated patients were studied. Data collected include age, gender, diagnosis, indication for endoluminal treatment, type of endograft, and time of follow up. All patients (n = 16; mean age, 61 years; range, 21-82 years) underwent computed tomography (CT) for location of the lesion and planning of the intervention. Time of follow-up with CT scan ranged from 1 to 61 months. Indications for endovascular treatment were degenerative aneurysm (n = 7; 44%), aortic dissection (n = 2; 12%), perforated aortic ulcer (n = 4; 25%), and traumatic aortic injury (n = 3; 19%). Three patients suffered from a collapse of the endograft (one patient distal, two patients proximal) between 3 and 8 days after endovascular treatment. These patients were younger (mean age, 37 ± 25 years vs. 67 ± 16 years; P 0.05]; distal, 45 ± 23.5% vs. 38 ± 21.7% [P > 0.05]). Proximal collapse was corrected by placing a bare stent. In conclusion, risk factors for stent-graft collapse are a small lumen of the aorta and a small radius of the aortic arch curvature (young patients), as well as oversizing, which is an important risk factor and is described for different types of endografts and protheses (Gore TAG and Cook Zenith). Dilatation of the collapsed stent-graft is not sufficient. Following therapy implantation of a second stent or surgery is necessary in patients with a proximal endograft collapse. Distal endograft collapse can possibly be treated conservatively under close follow-up.

  6. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  7. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  8. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation

  9. Multimodal Therapy for the Treatment of Severe Ischemic Stroke Combining Endovascular Embolectomy and Stenting of Long Intracranial Artery Occlusion

    Science.gov (United States)

    Bunc, Matjaž; Kocijančič, Igor J.; Pregelj, Rado; Dolenc, Vinko V.

    2010-01-01

    Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who—according to the National Institute of Health Stroke Scale (NIHSS)—was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach—without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA. PMID:20671974

  10. Multimodal therapy for the treatment of severe ischemic stroke combining endovascular embolectomy and stenting of long intracranial artery occlusion.

    Science.gov (United States)

    Bunc, Matjaz; Kocijancic, Igor J; Pregelj, Rado; Dolenc, Vinko V

    2010-01-01

    Embolic occlusion of cerebral arteries is a major cause for stroke. Intravenous thrombolysis showed positive results in this condition, however even when strict criteria are used, the risk of hemorrhagic transformation is possible. Microsurgical embolectomy has been described earlier. Purpose. We performed multimodal therapy of cerebral artery occlusion. Case Report. We present a case of a 49-year-old female patient who-according to the National Institute of Health Stroke Scale (NIHSS)-was rated as 19 due to acute occlusion of the horizontal segment of the left middle cerebral artery (MCA). After failed i.v. thrombolysis, only a part of the clot could be evacuated by the endovascular approach-without restoration of blood flow. Normal patency of the left MCA was re-established after stenting. Within 72 hours, the patient had an NIHSS score of 14, with a small haematoma in the left hemisphere. Conclusion. In our case multimodal therapy combining i.v. thrombolysis, mechanical disruption of thrombus, MCA stenting and platelet function antagonists, resulted in successful recanalization of the acutely occluded left MCA.

  11. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  12. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    Science.gov (United States)

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  13. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  14. Effects of the Temporary Placement of a Self-Expandable Metallic Stent in Benign Pyloric Stenosis

    OpenAIRE

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-01-01

    Background/Aims The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Methods Twenty-two patients with benign sten...

  15. Plastic or metal stents for benign extrahepatic biliary strictures: a systematic review

    Directory of Open Access Journals (Sweden)

    Vleggaar Frank P

    2009-12-01

    Full Text Available Abstract Background Benign biliary strictures may be a consequence of surgical procedures, chronic pancreatitis or iatrogenic injuries to the ampulla. Stents are increasingly being used for this indication, however it is not completely clear which stent type should be preferred. Methods A systematic review on stent placement for benign extrahepatic biliary strictures was performed after searching PubMed and EMBASE databases. Data were pooled and evaluated for technical success, clinical success and complications. Results In total, 47 studies (1116 patients on outcome of stent placement were identified. No randomized controlled trials (RCTs, one non-randomized comparative studies and 46 case series were found. Technical success was 98,9% for uncovered self-expandable metal stents (uSEMS, 94,8% for single plastic stents and 94,0% for multiple plastic stents. Overall clinical success rate was highest for placement of multiple plastic stents (94,3% followed by uSEMS (79,5% and single plastic stents (59.6%. Complications occurred more frequently with uSEMS (39.5% compared with single plastic stents (36.0% and multiple plastic stents (20,3%. Conclusion Based on clinical success and risk of complications, placement of multiple plastic stents is currently the best choice. The evolving role of cSEMS placement as a more patient friendly and cost effective treatment for benign biliary strictures needs further elucidation. There is a need for RCTs comparing different stent types for this indication.

  16. Nursing experience in clinical endovascular treatment for renal artery aneurysms

    International Nuclear Information System (INIS)

    Dong Yanfen; Pan Xiaoxia; Luan Shaoliang; Wei Ren

    2012-01-01

    Objective: To discuss the standardized clinical nursing measures for patients receiving endovascular treatment of renal artery aneurysms. Methods: The clinical data of 9 patients with renal artery aneurysm, who were admitted to authors' hospital during the period from Jan. 2010 to Aug. 2011 and received endovascular treatment, were retrospectively analyzed. The related nursing points as well as the received endovascular. Results: A total of 9 cases with renal artery aneurysm were treated nursing measures were summarized. Results: A total of 9 cases with renal artery aneurysm were with interventional management, including embolization (n = 6), stent implantation (n = 2) and stent implantation together with coil embolization (n = 1). The mean hospitalization time was (10±2) days. Postoperative retention of urine was observed in one patient and postoperative retroperitoneal hemorrhage occurred in another patient. Neither nursing-related nor operation-related complications occurred. Conclusion: Standardized perioperative nursing care for patients with renal artery aneurysm can surely help enhance the patient's tolerance to the surgery, and effectively prevent the complications. (authors)

  17. Insertion of a self-expandable metallic stent in canine lacrimal Sac : a long-term evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Sung, Kyu Bo; Yoon, Hyun Ki [Univ. of Ulsan, Ulsan (Korea, Republic of). College of Medicine; Kwon, Soon Tae [Chungnam National Univ., Taejon (Korea, Republic of). Medical School; Lee, Ho Jung; Lee, In Chul; Kim, Tae Hyung; Park, Sang Soo; Huh, Soo Jin [Univ. of Ulsan, Ulsan (Korea, Republic of). College of Medicine

    1998-01-01

    To evaluate the feasibility and long-term outcome of the use of self-expandable metallic Z-stents in the canine lacrimal sac. Stent placement was technically successful and well tolerated in all but one lacrimal sac, in which the stent was misplaced. At three and six months after stent placement, stent wires were not encased by epithelium, but at nine months, and one, two and three years after placement, six of the 12 stents had become encased in a proliferation of this where the stent wires contacted the lacrimal sac wall. In no lacrimal system in which stent placement had been successful was migration, stenosis or obstruction of the lacrimal system observed. One misplaced stent caused obstruction of the lacrimal sac, however . In 11 of 12 case (92%), fluoroscopic placement of an expandable metallic stent in the canine lacrimal sac was successful: in 6 of 8 cases (75%), the stent wires became encased by a proliferation of mucosa, but during long-term follow-up of 9 months to 3 years, no obstruction was observed. (author). 20 refs., 1 tab., 5 figs.

  18. Insertion of a self-expandable metallic stent in canine lacrimal Sac : a long-term evaluation

    International Nuclear Information System (INIS)

    Song, Ho Young; Sung, Kyu Bo; Yoon, Hyun Ki; Kwon, Soon Tae; Lee, Ho Jung; Lee, In Chul; Kim, Tae Hyung; Park, Sang Soo; Huh, Soo Jin

    1998-01-01

    To evaluate the feasibility and long-term outcome of the use of self-expandable metallic Z-stents in the canine lacrimal sac. Stent placement was technically successful and well tolerated in all but one lacrimal sac, in which the stent was misplaced. At three and six months after stent placement, stent wires were not encased by epithelium, but at nine months, and one, two and three years after placement, six of the 12 stents had become encased in a proliferation of this where the stent wires contacted the lacrimal sac wall. In no lacrimal system in which stent placement had been successful was migration, stenosis or obstruction of the lacrimal system observed. One misplaced stent caused obstruction of the lacrimal sac, however . In 11 of 12 case (92%), fluoroscopic placement of an expandable metallic stent in the canine lacrimal sac was successful: in 6 of 8 cases (75%), the stent wires became encased by a proliferation of mucosa, but during long-term follow-up of 9 months to 3 years, no obstruction was observed. (author). 20 refs., 1 tab., 5 figs

  19. Emergency endovascular management of peripheral artery aneurysms and pseudoaneurysms – a review

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Endovascular stenting has been successfully employed in the management of aortic aneurysms; however, its use in managing peripheral arterial conditions remains questionable. We review the utility of endovascular technique in the management of peripheral arterial conditions like aneurysms, pseudoaneurysms and arterio-venous fistulas in the emergency setting. Though long term data about graft patency rates is not yet available, the endovascular approach appears to be a useful minimally invasive technique in situations where open repair is either difficult or not feasible.

  20. Treatment of traumatic internal carotid artery pseudoaneurysms with willis covered stents: a midterm follow-up result

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Li Yongdong; Gu Binxian; Fang Chun; Tan Huaqiao; Wang Ju; Zhang Peilei

    2010-01-01

    Objective: To evaluate the efficacy and mid-term follow-up results of endovascular treatment with Willis covered stent for traumatic pseudoaneurysms located in the internal carotid artery (ICA). Methods: ICA angiography was performed in 38 patients with traumatic brain and neck injury. Of the 38 patients, 13 delayed traumatic pseudoaneurysms were found. All the pseudoaneurysms were treated with Willis covered stents. Follow-up angiography was performed at 1, 3, 6 and 12 months after the procedure, and the results were categorized as complete or incomplete occlusion. Clinical manifestations were graded as full recovery, improvement, unchanged and aggravation. Results: Willis covered stent placement was technically successful in all traumatic pseudoaneurysms. No procedure-related complications occurred. The initial angiographic results showed a complete occlusion in 9 patients, and an incomplete occlusion in 4. The angiographic follow-up within 3-12 months exhibited a complete occlusion in 12 patients and the parent arteries remained patency in all patients. The clinical follow-up observation demonstrated that full recovery was obtained in 11 patients, clinical improvement in one, and unchanged condition in one. No morbidity or mortality occurred. Conclusion: Willis covered stent implantation is a feasible and practical treatment for traumatic pseudoaneurysms located in the ICA. This technique can well preserve the parent artery with excellent therapeutic results. (authors)

  1. Transpedal approach for iliac artery stenting: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Zachariah, Jips J., E-mail: jzachariah@chpnet.org [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Ratcliffe, Justin A.; Ruisi, Michael; Puma, Joseph [Mount Sinai Beth Israel Hospital, New York, NY (Israel); Bertrand, Olivier [Quebec Heart and Lung Institute, Quebec (Canada); Kwan, Tak [Mount Sinai Beth Israel Hospital, New York, NY (Israel)

    2016-12-15

    Objective: To demonstrate the safety and feasibility of the transpedal approach as an alternate arterial access site for iliac artery intervention. Background: The common femoral artery is the traditional access site for the endovascular treatment of iliac artery stenoses. However, this approach is associated with complication rates as high as 2%, including retroperitoneal bleeding which carries high patient morbidity and mortality. Furthermore, the standard femoral approach is associated with longer recovery times and longer time to ambulation which are important considerations especially when performing procedures in an ambulatory setting. Methods: Twelve patients were prospectively followed after treatment for symptomatic iliac artery stenosis via transpedal access. Under ultrasound guidance, one of the pedal arteries was visualized and accessed, and stenting of the iliac arteries were performed as per protocol. The patient was monitored immediately post procedure and clinical follow up was performed at one week and one month later. Results: The average age of the patients was 71 years old. 58% were male. Most patients had Rutherford class III symptoms. Successful stent placement was achieved in all 12 patients via transpedal access. No conversion to femoral access was required. No complications immediately post procedure nor at any time period during follow up were noted. Lower extremity arterial duplex at one month showed patent stents and patent pedal access site vessels in all patients. Conclusion: Transpedal arterial access may be a safe and feasible approach for iliac artery stenting. Given the possible benefits of avoiding femoral artery access, larger studies should be conducted directly comparing the different approaches.

  2. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Expandable metallic stents for tracheobronchial stenoses in esophageal cancer.

    Science.gov (United States)

    Takamori, S; Fujita, H; Hayashi, A; Tayama, K; Mitsuoka, M; Ohtsuka, S; Shirouzu, K

    1996-09-01

    Tracheobronchial stenosis in patients with esophageal cancer can be life threatening. Few reports have discussed use of expandable metallic stents for central airway stenoses in patients with esophageal cancer. Twelve patients with esophageal cancer underwent placement of expandable metallic stents for respiratory distress caused by tracheobronchial stricture. Single or double metallic stents were placed in the stenotic airways under fluoroscopic guidance. Improvement in respiratory symptoms and clinical outcome were assessed. Most stenoses were located in the trachea or the left main bronchus. From one to four expandable metallic stents were placed in each stricture site, with immediate relief of respiratory symptoms in 8 patients. One patient with tracheomalacia in alive 3 years after stent placement and another is alive 6 months after stent insertion. The other 10 patients lived from 10 to 70 days (mean; survival, 35 days) after stent placement. Death was due to progression of disease. Although metallic stents are useful for relieving respiratory distress in patients with advanced esophageal cancer, additional therapies should be considered.

  4. Endovascular Treatment of an Aortobronchial Fistula

    International Nuclear Information System (INIS)

    Numan, Fueruezan; Arbatli, Harun; Yagan, Naci; Demirsoy, Ergun; Soenmez, Binguer

    2004-01-01

    A 67-year-old man operated on 8 years previously for type B aortic dissection presented with two episodes of massive hemoptysis. An aortobronchial fistula was suspected with spiral computed tomography angiography, and showed a small pseudoaneurysm corresponding to the distal anastomotic site. The patient underwent endovascular stent-graft implantation and is asymptomatic 8 months after the procedure

  5. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed....... All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean...... arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered. Patients with cancer may only need treatment for the acute bleeding episode, and an endovascular approach has the advantage...

  6. Correção endovascular de persistência do conduto arterioso em paciente adulto Endovascular approach for persistent ductus arteriosus closure in adult patient

    Directory of Open Access Journals (Sweden)

    José Carlos Dorsa Vieira Pontes

    2010-03-01

    Full Text Available O tratamento da Persistência do Canal Arterial (PCA, em adultos, ainda é controverso. A utilização de próteses auto-expansíveis tem-se mostrado como uma alternativa eficaz ao tratamento cirúrgico. Apresentamos um caso de uma paciente de 45 anos submetida ao tratamento endovascular com o uso de stent auto-expansível.The treatment for closure of persistent ductus arteriosus (PDA in adults still controversial. The endovascular approach has been shown as an effective alternative to surgical treatment. We report a case of 45 years old pacient submitted to endovascular approach for PDA closure.

  7. Percutaneous treatment of superior vena cava syndrome using metallic stents

    International Nuclear Information System (INIS)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma; Gamboa, Pablo; Tobio, Ricardo; Herrera, Marcos

    2003-01-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  8. Endoscopic placement of double-J ureteric stents in children as a treatment for primary hydronephrosis.

    Science.gov (United States)

    Pogorelić, Zenon; Brković, Tomislava; Budimir, Dražen; Todorić, Jakov; Košuljandić, Đurđica; Jerončić, Ana; Biočić, Mihovil; Saraga, Marijan

    2017-06-01

    The aim of this study was to determine the efficacy and potential complications of double-J ureteric stents in the treatment of primary hydronephrosis in pediatric patients. A retrospective case-records review of 133 patients (45 girls and 88 boys) treated because of primary hydronephrosis with double-J ureteric stents, in Department of Pediatric Surgery, Split University Hospital, between December 1997 and December 2014, was performed. Success of treatment, results of follow up investigations and complications were recorded. Patients were followed up clinically and radiologically for a minimum of 2 years following stent insertion. In all, 133 endoscopic double-J ureteric stents insertions were performed. Of the total number of patients, left-sided hydronephrosis was found in 82 patients, right-sided in 38, and bilateral in 13 patients. The median age of children was 2 years (range 0-17 years). Mean hospital stay was 2 days (range 1-10 days). In primary hydronephrosis, double-J ureteric stenting alone was effective with resolution of hydronephrosis in 73% of cases (97/133 insertions). Regarding the age of the patients the highest success of 83.5% was achieved in age group 0-4 years. Success in groups 5-9 years; 10-14 years and 15-17 years were 47%; 33.5% and 0%, respectively. Several complications have been recorded: symptomatic infections, migration in the renal pelvis and bladder, progression of hydronephrosis, spontaneously prolapse of prosthesis, bleeding and perforation of the renal pelvis. A significant, decreasing trend in success rates by age of participants was observed (p hydronephrosis. Endoscopic placement of ureteric double-J stents should be considered as a first-line treatment in the management of primary hydronephrosis especially in children till 4 years of age, with success rate of 83.5% and without the need for conventional surgery. In a case of failure we are time-consuming to definitive surgery.

  9. Risk Factors for Migration, Fracture, and Dislocation of Pancreatic Stents

    Directory of Open Access Journals (Sweden)

    Yoshiaki Kawaguchi

    2015-01-01

    Full Text Available Aim. To analyze the risk factors for pancreatic stent migration, dislocation, and fracture in chronic pancreatitis patients with pancreatic strictures. Materials and Methods. Endoscopic stent placements (total 386 times were performed in 99 chronic pancreatitis patients with pancreatic duct stenosis at our institution between April 2006 and June 2014. We retrospectively examined the frequency of stent migration, dislocation, and fracture and analyzed the patient factors and stent factors. We also investigated the retrieval methods for migrated and fractured stents and their success rates. Results. The frequencies of stent migration, dislocation, and fracture were 1.5% (5/396, 0.8% (3/396, and 1.2% (4/396, respectively. No significant differences in the rates of migration, dislocation, or fracture were noted on the patient factors (etiology, cases undergoing endoscopic pancreatic sphincterotomy, location of pancreatic duct stenosis, existence of pancreatic stone, and approach from the main or minor papilla and stent factors (duration of stent placement, numbers of stent placements, stent shape, diameter, and length. Stent retrieval was successful in all cases of migration. In cases of fractured stents, retrieval was successful in 2 of 4 cases. Conclusion. Stent migration, fracture, and dislocation are relatively rare, but possible complications. A good understanding of retrieval techniques is necessary.

  10. Perioperative nursing for patients with diabetic foot receiving endovascular interventional therapy

    International Nuclear Information System (INIS)

    Yang Yang; Wang Feng; Li Ke; Li Cheng; Ji Donghua

    2010-01-01

    Objective: To study the effect of perioperative nursing on the living quality of patients with diabetic foot who are treated with endovascular interventional therapy. Methods: Specific perioperative nursing care plan was accordingly designed for 43 patients with diabetic foot. Endovascular balloon angioplasty and stent implantation were formed in these patients to treat their diabetic foot. The clinical results were observed. Results: Perioperative nursing effectively improved patient's limb blood supply, enhanced the healing of diabetic foot ulceration and increased the possibility of limb preservation. Conclusion: Endovascular therapy combined with corresponding perioperative nursing care can benefit more patients with diabetic foot. (authors)

  11. Treatment of Post-Stent Gastroesophageal Reflux by Anti-Reflux Z-Stent

    International Nuclear Information System (INIS)

    Davies, Roger Philip; Kew, Jacqueline; Byrne, Peter D.

    2000-01-01

    Severe symptoms of heartburn and retrosternal pain consistent with gastro-esophageal reflux (GER) developed in a patient following placement of a conventional self-expanding 16-24-mm-diameter x 12-cm-long esophageal stent across the gastroesophageal junction to treat an obstructing esophageal carcinoma. A second 18-mm-diameter x 10-cm-long esophageal stent with anti-reflux valve was deployed coaxially and reduced symptomatic GER immediately. Improvement was sustained at 4-month follow-up. An anti-reflux stent can be successfully used to treat significant symptomatic GER after conventional stenting

  12. Safety and benefits of self-expandable metallic stents with chemotherapy for malignant gastric outlet obstruction.

    Science.gov (United States)

    Miyabe, Katsuyuki; Hayashi, Kazuki; Nakazawa, Takahiro; Sano, Hitoshi; Yamada, Tomonori; Takada, Hiroki; Naitoh, Itaru; Shimizu, Shuya; Kondo, Hiromu; Nishi, Yuji; Yoshida, Michihiro; Umemura, Shuichiro; Hori, Yasuki; Kato, Akihisa; Ohara, Hirotaka; Joh, Takashi

    2015-07-01

    The influence of chemotherapy on placement of self-expandable metallic stents (SEMS) for malignant gastric outlet obstruction (MGOO) has not been evaluated extensively. We investigated the influence of chemotherapy on the clinical outcomes of SEMS placement for MGOO. A total of 152 cancer patients with MGOO from a university hospital and affiliate hospitals were included. The patients were classified according to chemotherapy status and evaluated for palliative efficacy and safety of SEMS placement. Technical success rate, time to oral intake, and parameters indicating improvement of physical condition did not differ between the with- and without-chemotherapy groups after stent placement. Re-intervention and stent migration were significantly more frequent in the with-chemotherapy group than in the without-chemotherapy group after stent placement (re-intervention, 32.4% vs 7.8%, P = 0.0005; stent migration, 13.5% vs 1.7%, P = 0.0097). The frequency of adverse events did not differ between the with- and without-chemotherapy groups. Although chemotherapy after stent placement was an independent predictive factor for shortening the stent patency period (hazard ratio [HR], 3.10; P = 0.0264), the use of additional stents facilitated uneventful recovery and further prolonged survival time (HR, 0.60; P = 0.0132). Various cancer patients with MGOO can undergo SEMS placement safely regardless of chemotherapy, and concurrent chemotherapy after stent placement can prolong survival time, although re-intervention and stent migration may be increased. © 2015 The Authors. Digestive Endoscopy © 2015 Japan Gastroenterological Endoscopy Society.

  13. The application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement

    International Nuclear Information System (INIS)

    Wei Ning; Xu Hao; Zu Maoheng; Gu Yuming; Li Gang; Zhang Qingqiao; Xu Wei; Cui Yanfeng; Liu Hongtao; Wang Wenliang

    2012-01-01

    Objective: To evaluate the application of spiral-CT and 3D-imaging of airway for observation of efficacy and complication after tracheobronchial stent placement. Methods: Thirty-one patients treated with tracheal stents were retrospectively analyzed, of which there were 27 malignant tracheal stenosis, 2 benign tracheal stenosis, 1 bronchial remnant fistula and 1 gastroesophageal anastomosis tracheal fistula. The spiral-CT and 3D-imagings were analyzed and the location, shape and complication of the stents were assessed. Results: Thirty-one patients were treated with 8 Z-type stainless steel stents and 28 Ni-Ti memory alloy stents. The stents of 22 cases remained patent in the original position and restenosis was occurred in 5 cases, migration in 3 cases and fracture in 1 case. All the CT features were performed and reconstructed on the workstation, using multiplanar reconstruction, volume rendering, and CT virtual endoscopy. The location of tracheal stenosis and fistula were showed in different angle, and the location, shape of the stents, and the complications (such as restenosis, fracture) as well. Conclusion: Spiral-CT and 3D-imaging is a rapid, simple and effective method in assessing tracheal stent implantation and complication, therefore, it is of great value in clinical practice. (authors)

  14. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  15. [Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms].

    Science.gov (United States)

    Pitton, M B; Schmiedt, W; Neufang, A; Düber, C; Thelen, M

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings.

  16. Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitton, M.B.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings. (orig.)

  17. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  18. Stent placement for esophageal strictures : an update

    NARCIS (Netherlands)

    Hirdes, Meike Madeleine Catharine; Vleggaar, Frank Paul; Siersema, Peter Derk

    The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief

  19. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Ying-Nan Tsai

    2018-01-01

    Full Text Available Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG (n = 5 and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG (n = 2. A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks.

  20. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy.

    Science.gov (United States)

    Tsai, Ying-Nan; Wang, Hsiu-Po; Huang, Chih-Kun; Chang, Po-Chin; Lin, I-Chang; Tai, Chi-Ming

    2018-01-01

    Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS) in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG) (n = 5) and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG) (n = 2). A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks. Copyright © 2017. Published by Elsevier Taiwan.

  1. Management of stenosis lesions during the period of endovascular treatment for acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Hong-xing HAN

    2017-11-01

    Full Text Available Objective To investigate the management of stenosis lesions during endovascular treatment for acute ischemic stroke. Methods A total of 36 acute ischemic stroke patients combined with intracranial/extracranial arterial stenosis were treated with endovascular treatment or bridging treatment. Time from aggravation on admission or in hospital stay to femoral artery puncture, from femoral arterypuncture to recanalization were recorded. Modified Thrombolysis in Cerebral Infarction (mTICI was usedto assess the recanalization immediately after operation. Modified Rankin Scale (mRS was used to evaluate prognosis at 90 d after operation. Occurrence rate of symptomatic intracranial hemorrhage and mortality were recorded. Results Among 36 patients, 13 patients (36.11% underwent intravenous thrombolysis and then endovascular thrombectomy. In all patients, there were 21 (58.33% with intracranial stenosis and 15 (41.67% with extracranial stenosis, 16 (44.44% with anterior circulation stenosis and 20 (55.56% with posterior circulation stenosis. Stent thrombectomy was used in 25 patients (69.44% , while balloon dilatation and/or stent implantation was used in 11 patients (30.56% . For 21 patients with intracranial arterial stenosis, 4 were treated with balloon dilatation only, 9 with Wingspan self-expandable stents and 8 with Apollo balloon-expandable stents. Fifteen patients with extracranial arterial stenosis were treated with balloon dilatation and stent implantation. A total of 33 patients (91.67% achieved recanalization (mTICI 2b-3 grade, 21 patients (58.33% had good outcomes (mRS ≤ 2 score, while symptomatic intracranial hemorrhage occurred in 2 patients (5.56% and 5 (13.89% died. There were no statistically significant differences in the rate of good prognosis, symptomatic intracranial hemorrhage and mortality between intracranial and extracranial arterial stenosis, anterior and posterior circulation stenosis (Fisher exact probability: P > 0.05, for

  2. Metallic stents for management of malignant biliary obstruction

    International Nuclear Information System (INIS)

    Lee, Byung Hee; Do, Young Soo; Byun, Hong Sik; Kim, Kie Hwan; Chin, Soo Yil

    1992-01-01

    In patients with inoperable malignant biliary obstruction, percutaneous transhepatic biliary drainage (PTBD) has been the method of choice for palliative treatment. All patients except three had undergone PTBD, and the stents were placed 5-7 days after the initial drainage procedure. Three patients underwent stent placement on the same day of PTBD. External drainage catheter is converted to various types of tube endoprostheses with associated physiologic and psychologic benefits. Tube stents, however, have some problems such as migration, occlusion, and traumatic implantation procedure. We report our experiences and clinical results of percutaneous placement of metallic stents in 40 patients with malignant biliary obstruction

  3. Metallic stents for management of malignant biliary obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Hee; Do, Young Soo; Byun, Hong Sik; Kim, Kie Hwan; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1992-11-15

    In patients with inoperable malignant biliary obstruction, percutaneous transhepatic biliary drainage (PTBD) has been the method of choice for palliative treatment. All patients except three had undergone PTBD, and the stents were placed 5-7 days after the initial drainage procedure. Three patients underwent stent placement on the same day of PTBD. External drainage catheter is converted to various types of tube endoprostheses with associated physiologic and psychologic benefits. Tube stents, however, have some problems such as migration, occlusion, and traumatic implantation procedure. We report our experiences and clinical results of percutaneous placement of metallic stents in 40 patients with malignant biliary obstruction.

  4. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  5. Endovascular image-guided treatment of in-vivo model aneurysms with asymmetric vascular stents (AVS): evaluation with time-density curve angiographic analysis and histology.

    Science.gov (United States)

    Dohatcu, A; Ionita, C N; Paciorek, A; Bednarek, D R; Hoffmann, K R; Rudin, S

    2008-01-01

    In this study, we compare the results obtained from Time-Density Curve (TDC) analysis of angiographic imaging sequences with histological evaluation for a rabbit aneurysm model treated with standard stents and new asymmetric vascular stents (AVS) placed by image-guided endovascular deployment. AVSs are stents having a low-porosity patch region designed to cover the aneurysm neck and occlude blood flow inside. To evaluate the AVSs, rabbits with elastase-induced aneurysm models (n=20) were divided into three groups: the first (n=10) was treated with an AVS, the second (n=5) with a non-patch standard coronary stent, and third was untreated as a control (n=5). We used TDC analysis to measure how much contrast media entered the aneurysm before and after treatment. TDCs track contrast-media-density changes as a function of time over the region of interest in x-ray DSA cine-sequences. After 28 days, the animals were sacrificed and the explanted specimens were histologically evaluated. The first group showed an average reduction of contrast flow into the aneurysm of 95% after treatment with an AVS with fully developed thrombus at 28 days follow-up. The rabbits treated with standard stents showed an increase in TDC residency time after treatment and partial-thrombogenesis. The untreated control aneurysms displayed no reduction in flow and were still patent at follow-up. The quantitative TDC analysis findings were confirmed by histological evaluation suggesting that the new AVS has great potential as a definitive treatment for cerebro-vascular aneurysms and that angiographic TDC analysis can provide in-vivo verification.

  6. Long-Term Type 1 Diabetes Enhances In-Stent Restenosis after Aortic Stenting in Diabetes-Prone BB Rats

    Directory of Open Access Journals (Sweden)

    Geanina Onuta

    2011-01-01

    Full Text Available Type 1 diabetic patients have increased risk of developing in-stent restenosis following endovascular stenting. Underlying pathogenetic mechanisms are not fully understood partly due to the lack of a relevant animal model to study the effect(s of long-term autoimmune diabetes on development of in-stent restenosis. We here describe the development of in-stent restenosis in long-term (~7 months spontaneously diabetic and age-matched, thymectomized, nondiabetic Diabetes Prone BioBreeding (BBDP rats (n=6-7 in each group. Diabetes was suboptimally treated with insulin and was characterized by significant hyperglycaemia, polyuria, proteinuria, and increased HbA1c levels. Stented abdominal aortas were harvested 28 days after stenting. Computerized morphometric analysis revealed significantly increased neointima formation in long-term diabetic rats compared with nondiabetic controls. In conclusion, long-term autoimmune diabetes in BBDP rats enhances in-stent restenosis. This model can be used to study the underlying pathogenetic mechanisms of diabetes-enhanced in-stent restenosis as well as to test new therapeutic modalities.

  7. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for

  8. Clinical Outcomes of Self-Expandable Metal Stents for Malignant Rectal Obstruction.

    Science.gov (United States)

    Lee, Hyun Jung; Hong, Sung Pil; Cheon, Jae Hee; Kim, Tae Il; Kim, Won Ho; Park, Soo Jung

    2018-01-01

    Self-expandable metal stents are widely used to treat malignant colorectal obstruction. However, data on clinical outcomes of stent placement for rectal obstruction specifically are lacking. We aimed to investigate the clinical outcomes of self-expandable metal stents in malignant rectal obstruction in comparison with those in left colonic obstruction and to identify factors associated with clinical failure and complication. This was a retrospective study. The study was conducted at a tertiary care center. Between January 2005 and December 2013, medical charts of patients who underwent stent placement for malignant rectal or left colonic obstruction were reviewed retrospectively. Study intervention included self-expandable metal stent placement. Technical success, clinical success, and complications were measured. Technical success rates for the 2 study groups (rectum vs left colon, 93.5% vs 93.1%; p = 0.86) did not differ significantly; however, the clinical success rate was lower in patients with rectal obstruction (85.4% vs 92.1%; p = 0.02). In addition, the complication rate was higher in patients with rectal obstruction (37.4% vs 25.1%; p = 0.01). Patients with rectal obstruction showed higher rates of obstruction because of extracolonic malignancy (33.8% vs 15.8%; p stent use for palliation (78.6% vs 56.3%; p stent usage to be independent risk factors for clinical failure. Factors predictive of complications in the palliative group were total obstruction, obstruction because of extracolonic malignancy, and covered stent usage. This was a retrospective, single-center study. The efficacy and safety of stent placement for malignant rectal obstruction were comparable with those for left colonic obstruction. However, obstruction attributed to extracolonic malignancy, use of covered stents, and total obstruction negatively impacted clinical outcomes of self-expandable metal stent placement and must be considered by endoscopists. See Video Abstract at http

  9. Alternativa técnica no tratamento endovascular dos aneurismas da artéria poplítea A technical alternative for the endovascular treatment of popliteal artery aneurysms

    Directory of Open Access Journals (Sweden)

    Marcelo Ferreira

    2008-03-01

    Full Text Available O aneurisma de artéria poplítea é relativamente raro, porém representa cerca de 85% de todos os aneurismas arteriais periféricos. Apresenta-se geralmente com um quadro de complicação isquêmica e elevado risco de perda do membro acometido. Em função disso, preconiza-se seu tratamento eletivo, atualmente realizado com resultados satisfatórios pela técnica endovascular. Relatamos nossa experiência com a utilização do stent de nitinol auto-expansível revestido com PTFEe - Fluency (Bard, Alemanha, reforçado internamente com o stent de nitinol auto-expansível Zilver (Cook, EUA no tratamento de um aneurisma de artéria poplítea.Popliteal artery aneurysm is relatively rare, but represents around 85% of all peripheral arterial aneurysms. It is usually presented with ischemic complication and high risk of limb loss. For that reason, its elective treatment is indicated and currently carried through with satisfactory results using endovascular techniques. We describe our experience with the use of an ePTFE-covered nitinol self-expandable stent graft - Fluency (Bard, Germany, reinforced internally with the nitinol self-expandable Zilver stent (Cook, USA for the treatment of a popliteal artery aneurism.

  10. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  11. Recognition and treatment of outflow tract stenosis during and after endovascular exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Lu Qingsheng; Jing Zaiping; Zhao Zhiqing; Bao Junmin; Zhao Jun; Feng Xiang; Feng Rui; Huang Sheng

    2003-01-01

    Objective: To study the cognition and treatment of outflow tract stenosis in and after endovascular exclusion for abdominal aortic aneurysm. Methods: From Mar 1997 to Oct 2002, in 136 patients undergoing abdominal aortic aneurysm endovascular exclusion, 8 patients had outflow tract stenosis during the operation, and 3 patients had outflow tract stenosis after operation. The stenosis of 5 patients occurred at the crotch of the graft-stent. PTA was done in 7 patients and stents were placed in stenotic segment in 2 patients. 2 patients were treated with crossover operation. Results: Following up 1 month to 2 years, all patients have no lower limbs ischemia. Conclusions: The diagnosis of outflow tract stenosis during and after abdominal endovascular exclusion for aortic aneurysm must be in time. The treatment should be according to the different causes of stenosis

  12. Outcomes of Peripheral Endovascular Interventions Based on Hospital Volume: A Mini Review of Published Literature

    Directory of Open Access Journals (Sweden)

    Samir V Patel

    2016-01-01

    Full Text Available Previous literature showed hospital procedural volume is an independent predictor for outcomes of various cardiac procedures. However, very few studies shown similar results for peripheral endovascular interventions especially peripheral atherectomy. Here we are reviewing previously published articles to provide volume-outcome relationship for peripheral atherectomy and angioplasty with or without endovascular stenting. We found higher hospital volume significantly and independently lowers in-hospital mortality, amputation rates, peri-procedural complications, length and cost of hospitalization for peripheral endovascular interventions.

  13. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  14. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  15. Long-Term Efficacy of Percutaneous Internal Plastic Stent Placement for Non-anastomotic Biliary Stenosis After Liver Transplantation

    International Nuclear Information System (INIS)

    Lee, Eun Sun; Han, Joon Koo; Baek, Ji-Hyun; Suh, Suk-Won; Joo, Ijin; Yi, Nam-Joon; Lee, Kwang-Woong; Suh, Kyung-Suk

    2016-01-01

    PurposeWe aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents.Materials and MethodsThis study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34–68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based on clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29–9.95 years). We assessed treatment success rate and patient and graft survival times.ResultsDuring the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00–9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42–4.25).ConclusionsPercutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.

  16. Long-Term Efficacy of Percutaneous Internal Plastic Stent Placement for Non-anastomotic Biliary Stenosis After Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun, E-mail: seraph377@gmail.com; Han, Joon Koo, E-mail: hanjk@snu.ac.kr; Baek, Ji-Hyun, E-mail: 100paper@gmail.com [Seoul National University Hospital, Department of Radiology (Korea, Republic of); Suh, Suk-Won, E-mail: bomboy1@hanmail.net [Chung-Ang University Hospital, Department of Surgery (Korea, Republic of); Joo, Ijin, E-mail: hijijin@gmail.com [Seoul National University Hospital, Department of Radiology (Korea, Republic of); Yi, Nam-Joon, E-mail: gsleenj@hanmail.net; Lee, Kwang-Woong, E-mail: kwleegs@gmail.com; Suh, Kyung-Suk, E-mail: kssuh@snu.ac.kr [Seoul National University Hospital, Department of Surgery (Korea, Republic of)

    2016-06-15

    PurposeWe aimed to evaluate the long-term efficacy of percutaneous management of non-anastomotic biliary stenosis after liver transplantation, using plastic internal biliary stents.Materials and MethodsThis study included 35 cases (28 men, 7 women; mean age: 52.09 ± 8.13 years, range 34–68) in 33 patients who needed repeated interventional procedures because of biliary strictures. After classification of the biliary strictures, we inserted percutaneous biliary plastic stents through the T-tube or percutaneous transhepatic biliary drainage tracts. Stents were exchanged according to percutaneous methods at regular 2- to 6-month intervals. The stents were removed if the condition improved, as observed on cholangiogram as well as based on clinical findings. The median patient follow-up period after initial diagnosis and treatment was 6.04 years (range 0.29–9.95 years). We assessed treatment success rate and patient and graft survival times.ResultsDuring the follow-up period, 14 patients (14/33, 42.42 %) were successfully treated and were tube-free. The median tube-free time, time without a stent, was 4.13 years (range 1.00–9.01). In contrast, internal plastic stents remained in 9 patients (9/33, 27.27 %) until the last follow-up. These patients had acceptable hepatic function. Among the remaining 10 patients, 3 (3/33, 9.09 %) were lost to regular follow-up and the other 7 (7/33, 21.21 %) patients died. The overall graft loss rate was 20.0 % (7/35). The median time from initial treatment to graft loss was 1.84 years (range 0.42–4.25).ConclusionsPercutaneous plastic stents placement is technically feasible and clinically useful in patients with multiple biliary stenoses following liver transplantation.

  17. Long-Term Results of Stent Placement in Patients with Outflow Block After Living-Donor-Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Fujimori, Masashi, E-mail: fujimorim@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Department of Radiology (Japan); Yamakado, Koichiro, E-mail: yamakado47@gmail.com; Takaki, Haruyuki, E-mail: takaki-h@clin.medic.mie-u.ac.jp [Hyogo College of Medicine, Department of Radiology (Japan); Nakatsuka, Atsuhiro, E-mail: nakatuka@clin.medic.mie-u.ac.jp; Uraki, Junji, E-mail: junji@clin.medic.mie-u.ac.jp; Yamanaka, Takashi, E-mail: t-yama@clin.medic.mie-u.ac.jp; Hasegawa, Takaaki, E-mail: hasegawat@clin.medic.mie-u.ac.jp; Sugino, Yuichi, E-mail: ysugino23@clin.medic.mie-u.ac.jp; Nakajima, Ken, E-mail: k-nakajima@clin.medic.mie-u.ac.jp; Matsushita, Naritaka, E-mail: n-matsushita@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Department of Radiology (Japan); Mizuno, Shugo, E-mail: mizunos@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Hepatobiliary Pancreatic and Transplant Surgery (Japan); Sakuma, Hajime, E-mail: sakuma.mie@gmail.com [Mie University School of Medicine, Department of Radiology (Japan); Isaji, Shuji, E-mail: isaji-s@clin.medic.mie-u.ac.jp [Mie University School of Medicine, Hepatobiliary Pancreatic and Transplant Surgery (Japan)

    2016-04-15

    PurposeTo evaluate long-term results of stent placement retrospectively in patients with outflow block after living-donor-liver transplantation (LDLT).Materials and MethodsFor this institutional review board approved retrospective study conducted during 2002–2012, stents were placed in outflow veins in 15 patients (11.3 %, 15/133) (12 men; 3 female) in whom outflow block developed after LDLT. Their mean age was 52.3 years ± 15.3 (SD) (range, 4–69 years). Venous stenosis with a pressure gradient ≥5 mmHg (outflow block) was observed in the inferior vena cava in seven patients, hepatic vein in seven patients, and both in one patient. Technical success, change in a pressure gradient and clinical manifestations, and complications were evaluated. Overall survival of 15 patients undergoing outflow block stenting was compared with that of 116 patients without outflow block after LDLT.ResultsStents were placed across the outflow block veins without complications, lowering the pressure gradient ≤ 3 mmHg in all patients (100 %, 15/15). Clinical manifestations improved in 11 patients (73.3 %, 11/15), and all were discharged from the hospital. However, they did not improve in the other 4 patients (26.7 %, 4/15) who died in the hospital 1.0–3.7 months after stenting (mean, 2.0 ± 1.2 months). No significant difference in 5-year survival rates was found between patients with and without outflow block after LDLT (61.1 vs. 72.2 %, p = .405).ConclusionStenting is a feasible, safe, and useful therapeutic option to resolve outflow block following LDLT, providing equal survival to that of patients without outflow block.

  18. Innovative chimney-graft technique for endovascular repair of a pararenal abdominal aortic aneurysm.

    Science.gov (United States)

    Galiñanes, Edgar Luis; Hernandez-Vila, Eduardo A; Krajcer, Zvonimir

    2015-02-01

    After abdominal aortic aneurysm repair, progressive degeneration of the aneurysm can be challenging to treat. Multiple comorbidities and previous operations place such patients at high risk for repeat surgery. Endovascular repair is a possible alternative; however, challenging anatomy can push the limits of available technology. We describe the case of a 71-year-old man who presented with a 5.3-cm pararenal aneurysm 4 years after undergoing open abdominal aortic aneurysm repair. To avoid reoperation, we excluded the aneurysm by endovascular means, using visceral-artery stenting, a chimney-graft technique. Low-profile balloons on a monorail system enabled the rapid exchange of coronary wires via a buddy-wire technique. This novel approach facilitated stenting and simultaneous angioplasty of multiple visceral vessels and the abdominal aorta.

  19. The role of MR angiography before transjugular placement of a portosystemic stent shunt (TIPS)

    International Nuclear Information System (INIS)

    Mueller, M.F.; Siewert, B.; Kim, D.; Edelman, R.R.; Stokes, K.R.; Finn, J.P.

    1994-01-01

    The authors employed magnetic resonance angiography (MRA) to guide catheter placement for transjugular intrahepatic portosystemic stent shunt (TIPS) procedures in 14 of 24 patients, and compared the results to the 10 patients who did not have prior panning based on MRA. Two-dimensional time-of-flight venography was performed during breath holding, and projection venograms were formatted in sagittal, coronal and axial planes. MRA defined venous anatomy sufficiently well to shorten the procedure and helped to minimize invasiveness. With MRA guidance, intrahepatic needle punctures were significantly fewer (without MRA guidance: mean 12.1; with MRA guidance: mean 3.5, p [de

  20. Predictors of the patency of self-expandable metallic stents in malignant gastroduodenal obstruction.

    Science.gov (United States)

    Kim, Seung Han; Chun, Hoon Jai; Yoo, In Kyung; Lee, Jae Min; Nam, Seung Joo; Choi, Hyuk Soon; Kim, Eun Sun; Keum, Bora; Seo, Yeon Seok; Jeen, Yoon Tae; Lee, Hong Sik; Um, Soon Ho; Kim, Chang Duck

    2015-08-14

    To investigate the predictive factors of self-expandable metallic stent patency after stent placement in patients with inoperable malignant gastroduodenal obstruction. A total of 116 patients underwent stent placements for inoperable malignant gastroduodenal obstruction at a tertiary academic center. Clinical success was defined as acceptable decompression of the obstructive lesion within the malignant gastroduodenal neoplasm. We evaluated patient comorbidities and clinical statuses using the World Health Organization's scoring system and categorized patient responses to chemotherapy using the Response Evaluation Criteria in Solid Tumors criteria. We analyzed the relationships between possible predictive factors and stent patency. Self-expandable metallic stent placement was technically successful in all patients (100%), and the clinical success rate was 84.2%. In a multivariate Cox proportional hazards model, carcinoembryonic antigen (CEA) levels were correlated with a reduction in stent patency [P = 0.006; adjusted hazard ratio (aHR) = 2.92, 95%CI: 1.36-6.25]. Palliative chemotherapy was statistically associated with an increase in stent patency (P = 0.009; aHR = 0.27, 95%CI: 0.10-0.72). CEA levels can easily be measured at the time of stent placement and may help clinicians to predict stent patency and determine the appropriate stent procedure.

  1. Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks.

    Science.gov (United States)

    van Boeckel, Petra G A; Dua, Kulwinder S; Weusten, Bas L A M; Schmits, Ruben J H; Surapaneni, Naveen; Timmer, Robin; Vleggaar, Frank P; Siersema, Peter D

    2012-02-29

    Benign esophageal ruptures and anastomotic leaks are life-threatening conditions that are often treated surgically. Recently, placement of partially and fully covered metal or plastic stents has emerged as a minimally invasive treatment option. We aimed to determine the clinical effectiveness of covered stent placement for the treatment of esophageal ruptures and anastomotic leaks with special emphasis on different stent designs. Consecutive patients who underwent placement of a fully covered self-expandable metal stent (FSEMS), a partially covered SEMS (PSEMS) or a self-expanding plastic stent (SEPS) for a benign esophageal rupture or anastomotic leak after upper gastrointestinal surgery in the period 2007-2010 were included. Data on patient demographics, type of lesion, stent placement and removal, clinical success and complications were collected A total of 52 patients received 83 esophageal stents (61 PSEMS, 15 FSEMS, 7 SEPS) for an anastomotic leak (n=32), iatrogenic rupture (n=13), Boerhaave's syndrome (n=4) or other cause (n=3). Endoscopic stent removal was successful in all but eight patients treated with a PSEMS due to tissue ingrowth. Clinical success was achieved in 34 (76%, intention-to-treat: 65%) patients (PSEMS: 73%, FSEMS: 83%, SEPS: 83%) after a median of 1 (range 1-5) stent and a median stenting time of 39 (range 7-120) days. In total, 33 complications in 24 (46%) patients occurred (tissue in- or overgrowth (n=8), stent migration (n=10), ruptured stent cover (all Ultraflex; n=6), food obstruction (n=3), severe pain (n=2), esophageal rupture (n=2), hemorrhage (n=2)). One (2%) patient died of a stent-related cause. Covered stents placed for a period of 5-6 weeks may well be an alternative to surgery for treating benign esophageal ruptures or anastomotic leaks. As efficacy between PSEMS, FSEMS and SEPS is not different, stent choice should depend on expected risks of stent migration (SEPS and FSEMS) and tissue in- or overgrowth (PSEMS).

  2. Are bio-absorbable stents the future of SFA treatment?

    Science.gov (United States)

    Peeters, P; Keirse, K; Verbist, J; Deloose, K; Bosiers, M

    2010-02-01

    Several limitations inherent to the implantation of a metallic device, such as the occurrence of in-stent re-stenosis, in an arterial lumen intuitively explain the interest for developing bio-absorbable stents. Two main types of bio-absorbable stents currently exist: polymer stents and metallic stents. To date, no studies with bio-absorbable stents have been conducted in the superficial femoral artery (SFA). Because of their strut thickness and lack of radial force, polymer stents are no good candidates for endovascular use. Absorbable metal stents (AMS) do have the potential to perform well for artery treatment, although current evidence from in-human coronary and infrapopliteal studies yield unsatisfactory results. Drastic technological improvements are mandatory before AMS can be considered for every day practice. Yet, it is our belief that further development of other metal and non-metal bio-absorbable stents, with or without drug-coating, may lead to the creation of the ultimate SFA stent.

  3. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    International Nuclear Information System (INIS)

    Zhang, Qingqiao; Huang, Qianxin; Shen, Bin; Sun, Jingmin; Wang, Xiaolong; Liu, Hongtao

    2015-01-01

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or two hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion

  4. Self-expandable metal stents for obstructing colonic and extracolonic cancer

    DEFF Research Database (Denmark)

    van Hooft, Jeanin E; van Halsema, Emo E; Vanbiervliet, Geoffroy

    2014-01-01

    as a bridge to elective surgery is not recommended as a standard treatment of symptomatic left-sided malignant colonic obstruction (strong recommendation, high quality evidence). 3 For patients with potentially curable but obstructing left-sided colonic cancer, stent placement may be considered......, and Evaluation (GRADE) system was adopted to define the strength of recommendations and the quality of evidence. Main recommendations The following recommendations should only be applied after a thorough diagnostic evaluation including a contrast-enhanced computed tomography (CT) scan. 1 Prophylactic colonic...... stent placement is not recommended. Colonic stenting should be reserved for patients with clinical symptoms and imaging evidence of malignant large-bowel obstruction, without signs of perforation (strong recommendation, low quality evidence). 2 Colonic self-expandable metal stent (SEMS) placement...

  5. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    International Nuclear Information System (INIS)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja; Jung, Gyoo Sik

    2005-01-01

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  6. Treatment of malignant gastroduodenal obstruction with using a newly designed complex expandable nitinol stent: initial experiences

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Hee; Ko, Ji Ho; Lee, Eun Jung; Oh, Kyeng Seung; Huh, Jin Do; Cho, Young Duk; Park, Seun Ja [College of Medicine, Kosin University, Busan (Korea, Republic of); Jung, Gyoo Sik [Ulsan Hospital, Ulsan (Korea, Republic of)

    2005-12-15

    We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake capacity before and after the procedure. The complications were investigated during the follow up period. Stent placement was successful in all the patients. After stent placement, the symptoms improved in all but one patient. During the follow up, stent migration occurred in one patient (3%) at 34 days after the procedure. Despite the stent migration, the patient was able to resume a soft diet. Six patients developed recurrent symptoms of obstruction with tumor overgrowth at a mean of 145 days after the procedure; all the patients underwent coaxial placement of an additional stent with good results. One patient showed recurrence of obstruction due to tumor in-growth, and this was treated by placement of a second stent. Two patients with stent placement in the duodenum suffered from jaundice 26 days and 65 days, respectively, after their procedures. Placement of the newly designed complex expandable nitinol stent seems to be effective for the palliative treatment of malignant gastroduodenal obstructions. The new stent also seems to help overcome the

  7. Anastomotic pseudoaneurysms after surgical reconstruction: Outcomes after endovascular repair of symptomatic versus asymptomatic patients

    International Nuclear Information System (INIS)

    Nolz, Richard; Gschwendtner, Manfred; Jülg, Gregor; Plank, Christina; Beitzke, Dietrich; Teufelsbauer, Harald; Wibmer, Andreas; Kretschmer, Georg; Lammer, Johannes

    2012-01-01

    Purpose: To compare perioperative and follow-up outcomes of symptomatic versus asymptomatic patients following endovascular repair of anastomotic pseudoaneurysms (APAs) of the abdominal aorta and iliac arteries. Methods: We retrospectively evaluated 17 patients (two women), with a mean age of 66.2 years (range 30–83 years). Endovascular treatment was performed in ten symptomatic, and seven asymptomatic patients electively. Data included technical success, perioperative (within 30 days) mortality and morbidity, as well as stent graft-related complications, reinterventions, and survival in follow-up. Results: Bifurcated (n = 13), aortomonoiliac (n = 3) endoprosthesis and one aortic cuff were implanted with a primary technical success rate of 100%. The overall in-hospital mortality and morbidity rate was 11.8% and 35.3%. The mean survival was 36.5 (range 0–111) months. There was a clear trend toward a lower overall survival within hospital and at one and three years for symptomatic patients compared to asymptomatic patients. (47.7 (CI: 0–138.8) versus 52.6 (CI: 28.5–76.8) months (p = 0.274)). During follow-up, late stent graft related complications were observed in six patients (35.3%) necessitating eight endovascular reinterventions. Additional three patients with primary fistulas between the APA and the intestine were treated by late surgical revision. Conclusion: Endovascular therapy of APAs represents a considerable alternative to open surgical repair. Short proximal anchoring zones still pose a risk for endoleaks and unintentional overstenting of side branches with commercially available devices, but this might be overcome by use of fenestrated and branched stent grafts in elective cases.

  8. Clinical application of the Natural Y stent in the management of benign carinal stenosis.

    Science.gov (United States)

    Nam, Hae-Seong; Um, Sang Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung; Kim, Jhingook; Kim, Hojoong

    2009-08-01

    The Y-shaped structure of the carinal bifurcation causes difficulties in the treatment of carinal stenosis. We describe a new Y-shaped silicone stent, called the Natural Y stent. We investigated its clinical efficacy through a review of patients with benign carinal stenosis who undewent consecutive Natural Y stent placement. Between January 2004 and February 2008, 11 patients underwent ballooning, neodymium:yttrium-aluminum-garnet laser resection, or bougienation (by rigid bronchoscopy) to dilate the airway, followed by placement of the Natural Y stent. The underlying etiologies of carinal stenosis included posttuberculosis stricture in 7 patients (64%), postintubation stenosis in 2 (18%), and postoperative malacia in 2 (18%). All patients reported subjective symptomatic relief immediately after stent placement. No procedurally related deaths or immediate major complications occurred. Stent-related late complications included granulation tissue formation (64%) and mucostasis (18%, defined as > or = 50% narrowing). The median duration of overall stent placement was 439 days (range, 119 to 1729 days). The stents were successfully removed in 4 patients (36%) after a median of 409 days. The Natural Y stent provides an effective and feasible therapeutic modality in patients with benign carinal stenosis, with or without previous thoracic airway interventions.

  9. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  10. Endovascular Treatment for Fusiform Dilation of Internal Carotid Artery Following Craniopharyngioma Resection: A Case Illustration.

    Science.gov (United States)

    Li, Qiang; Wang, Chaohua; Xu, Jianguo; You, Chao

    2015-09-01

    Fusiform dilation of the internal carotid artery complicates aggressive craniopharyngioma resection and occurs mainly in children. We report a case to describe the availability of endovascular treatment for this rare entity. A 13-year-old boy presented with headache for 2 years after resection of craniopharyngioma. A fusiform dilation of the right carotid artery was found and was coiled using stent-assisted technique. Follow-up showed satisfactory outcome and disappearance of headache. To our knowledge, this is the first report regarding endovascular treatment for fusiform dilation of the internal carotid artery after craniopharyngioma resection. Stent-assisted coiling is a useful approach for fusiform dilation of the internal carotid artery following craniopharyngioma surgery. © The Author(s) 2014.

  11. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  12. An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization

    Energy Technology Data Exchange (ETDEWEB)

    Negri, Silvia; Ferraro, Stefania; Piffaretti, Gabriele, E-mail: gabriele.piffaretti@uninsubria.it; Rivolta, Nicola; Bossi, Matteo [University of Insubria School of Medicine, Vascular Surgery, Department of Surgical Sciences, Circolo University Hospital (Italy); Carrafiello, Gianpaolo [University of Insubria School of Medicine, Interventional Radiology, Department of Radiology, Circolo University Hospital (Italy); Castelli, Patrizio [University of Insubria School of Medicine, Vascular Surgery, Department of Surgical Sciences, Circolo University Hospital (Italy)

    2012-08-15

    A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.

  13. An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization

    International Nuclear Information System (INIS)

    Negri, Silvia; Ferraro, Stefania; Piffaretti, Gabriele; Rivolta, Nicola; Bossi, Matteo; Carrafiello, Gianpaolo; Castelli, Patrizio

    2012-01-01

    A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.

  14. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  15. Expandable metallic stent: experimental and clinical experience in tracheobronchial tree

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Young; Lee, Sang Young; Chung, Jin Young; Han, Young Min; Kim, Jong Soo; Choi, Ki Chul; Hong, Ki Whan; Rhee, Yang Kun [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    1991-05-15

    To maintain or reestablish an adequate airway in a patient with tracheobronchial narrowing coming from various causes, we constructed self-expanding metallic stents the same way Gianturco did, using them in 2 patients after an experimental study with rabbits. Twenty stents (10mm in diameter fully expanded and 20mm in length) were introduced into the trachea or bronchi of 10 Newzealand rabbits (weight, 2.5-3.0kg) through a 8.5 French Teflon sheath. No difficulties were encountered in the placement of the stents. At follow-up (4-12 weeks), no stent showed migration. Three rabbits died of pneumonia or bronchial perforation. Histologically, mucosal inflammation was noted at the sites of stent placement, and stent wires were covered by proliferated epithelium with intact cilia. During the last 4 months, 2 stents were used in 2 patients, one in a patient with endobronchial tuberculosis (3.0cm in length and 1.0cm in diameter fully expanded) and the other (3.0cm in length and 1.5cm in diameter) in a patient with a subglottic mass. In both patients the stents were successfully placed. Just after the placement of the stents dyspnea subsided in both patients, and there was no mortality or morbidity. These stents seem to be effective in the treatment of tracheobronchial stenosis, tracheomalacia, and airway collapse following tracheal reconstruction.

  16. Expandable metallic stent: experimental and clinical experience in tracheobronchial tree

    International Nuclear Information System (INIS)

    Song, Ho Young; Lee, Sang Young; Chung, Jin Young; Han, Young Min; Kim, Jong Soo; Choi, Ki Chul; Hong, Ki Whan; Rhee, Yang Kun

    1991-01-01

    To maintain or reestablish an adequate airway in a patient with tracheobronchial narrowing coming from various causes, we constructed self-expanding metallic stents the same way Gianturco did, using them in 2 patients after an experimental study with rabbits. Twenty stents (10mm in diameter fully expanded and 20mm in length) were introduced into the trachea or bronchi of 10 Newzealand rabbits (weight, 2.5-3.0kg) through a 8.5 French Teflon sheath. No difficulties were encountered in the placement of the stents. At follow-up (4-12 weeks), no stent showed migration. Three rabbits died of pneumonia or bronchial perforation. Histologically, mucosal inflammation was noted at the sites of stent placement, and stent wires were covered by proliferated epithelium with intact cilia. During the last 4 months, 2 stents were used in 2 patients, one in a patient with endobronchial tuberculosis (3.0cm in length and 1.0cm in diameter fully expanded) and the other (3.0cm in length and 1.5cm in diameter) in a patient with a subglottic mass. In both patients the stents were successfully placed. Just after the placement of the stents dyspnea subsided in both patients, and there was no mortality or morbidity. These stents seem to be effective in the treatment of tracheobronchial stenosis, tracheomalacia, and airway collapse following tracheal reconstruction

  17. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  18. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  19. A novel, ring-connected stent versus conventional GI stents: comparative study of physical properties and migration rates in a canine colon obstruction model.

    Science.gov (United States)

    Park, Hong Suk; Choo, In Wook; Seo, Soowon; Hyun, Dongho; Lim, Sooyoun; Kim, Jae J; Hong, Saet-Byul; Min, Byung-Hoon; Do, Young Soo; Choo, Sung Wook; Shin, Sung Wook; Park, Kwang Bo; Cho, Sung Ki

    2015-01-01

    Migration of stents is one of the most common adverse events in covered stent placement in GI tract obstruction. To compare physical property and migration rates in a canine colon obstruction model among a novel stent and conventional stents. Comparative physical test and animal study. Medical device testing laboratory and animal laboratory. Mongrel dogs (N=26). Surgical colon obstruction followed by placement of a novel (n=13) or conventional (n=13) stent. Physical properties, migration, and adverse events. The novel stent showed better flexibility, as in a physical test of longitudinal compressibility and axial force, than did conventional stents, and it withstood the fatigue test for 10 days. In terms of radial force and tensile strength, the novel stent showed the same or better results than conventional stents. In a canine colon obstruction model, the migration rate of a novel stent was significantly lower than that of a conventional stent (2/13, 15.4% vs 8/13, 61.5%; P=.008). Animal study of limited size. The novel, ring-connected stent is more flexible and more resistant to migration than the conventional stents. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  20. Preliminary clinical study on endovascular treatment of posterior inferior cerebellar artery aneurysms

    International Nuclear Information System (INIS)

    Zhao Bing; Zhong Ming; Tan Xianxi; Zheng Kuang; Zhang Mingsheng; Yin Jian; He Wengen

    2009-01-01

    Objective: To study the methods and results of endovascular treatment of posterior inferior cerebellar artery (PICA) aneurysms. Methods: Twenty-one patients with PICA aneurysms were treated with endovascular treatment. The locations of aneurysm on PICA were evaluated through the DSA. Eight patients received single coil embolization, 5 received liquid Glue embolization, 2 received coil embolization combined with liquid Glue, 2 received coil embolization assisted with stents, and 4 underwent occlusion of the parent PICA. Outcome was evaluated with the Glasgow outcome scale (GOS). Results: There were complete (100%) occlusion in 5 patients, near complete (> 90%) occlusion in 2, and incomplete (85%) occlusion in 1 in single coil embolization. Seven patients with Glue embolization (n=5) or combination with coils (n=2) exhibited complete (100%) occlusion. There were near complete (>90%) occlusion in 2 cases with coil assisted with stents. Complete occlusion of the parent PICA was achieved in 3 patients, and near complete occlusion of PICA in one case. One patient suffered from new neurological deficits, and one patient treated with coils and stents died. None of the patients suffered from re-bleeding. There patients received follow-up during a mean period of (22 ± 8) months. Overall long-term outcome was good (GOS score 4 or 5) in 17 patients, poor (GOS score 2 or 3) in 3, and fatal (GOS score 1 ) in one case. Conclusions: According to the location of aneurysms on PICA, aneurysms can be effectively and safely treated with endovascular embolization. (authors)

  1. Use of flow-diverting stents as salvage treatment following failed stent-assisted embolization of intracranial aneurysms.

    Science.gov (United States)

    Heiferman, Daniel M; Billingsley, Joshua T; Kasliwal, Manish K; Johnson, Andrew K; Keigher, Kiffon M; Frudit, Michel E; Moftakhar, Roham; Lopes, Demetrius K

    2016-07-01

    Flow-diverting stents, including the Pipeline embolization device (PED) and Silk, have been beneficial in the treatment of aneurysms previously unable to be approached via endovascular techniques. Recurrent aneurysms for which stent-assisted embolization has failed are a therapeutic challenge, given the existing intraluminal construct with continued blood flow into the aneurysm. We report our experience using flow-diverting stents in the repair of 25 aneurysms for which stent-assisted embolization had failed. Nineteen (76%) of these aneurysms at the 12-month follow-up showed improved Raymond class occlusion, with 38% being completely occluded, and all aneurysms demonstrated decreased filling. One patient developed a moderate permanent neurologic deficit. Appropriate stent sizing, proximal and distal construct coverage, and preventing flow diverter deployment between the previously deployed stent struts are important considerations to ensure wall apposition and prevention of endoleak. Flow diverters are shown to be a reasonable option for treating previously stented recurrent cerebral aneurysms. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Airway stents

    Science.gov (United States)

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  3. Innovations in vascular and endovascular surgery in Brazil: a data analysis study

    Directory of Open Access Journals (Sweden)

    Heriberto Brito de Oliveira

    2014-12-01

    Full Text Available Background:Innovations in vascular and endovascular surgery have important social and economic repercussions. Most endovascular devices used in Brazil are imported and, therefore, particularly expensive.Objective:To conduct a retrospective analysis of patent and regulatory approval data for newly developed vascular and endovascular devices, based on the number of patents registered at the Brazilian National Industrial Property Institute (INPI and the number of products approved by the National Health Surveillance Agency (ANVISA over recent years.Methods:This retrospective study involved electronic searches of the INPI (www.inpi.gov.br and ANVISA websites (www.anvisa.gov.br, for patents registered and products approved between January 1997 and December 2012.Results:The keywords used for the search ("catheter(s," "stent(s," "graft(s," and "wound dressing(s" returned a total of 701 new patents registered during the period studied. Thirty-four percent (n=237 of these were patents for wound dressings, while the remaining 66% (n=464 were for devices used in endovascular surgery. Only 7.8% (n=268 of the 3433 products approved by ANVISA during the period analyzed were produced in Brazil.Conclusions:The social and economic importance of innovations in health care highlights the need to monitor them, to register them and to support their production, in view of the need to develop local alternatives to imported health care technology.

  4. New treatment of iliac artery disease: focus on the Absolute Pro® Vascular Self-Expanding Stent System

    Directory of Open Access Journals (Sweden)

    Gates L

    2013-09-01

    Full Text Available Lindsay Gates, Jeffrey Indes Vascular and Endovascular Surgery, Yale University School of Medicine, New Haven, CT, USA Abstract: Management of iliac artery disease has evolved over the years, from a surgical-only approach to a primarily endovascular-only approach as the first line treatment option. This has been continuously improved upon with the advent of new devices and applied technologies. Most recently in particular, the literature has shown good, reliable outcomes with the use of self-expandable stents in iliac artery atherosclerotic lesions. Nevertheless, no device is without its limitations, and the Absolute Pro® Vascular Self-Expanding Stent System was designed with the intent of overcoming some of the shortcomings of other available stents while maintaining acceptable postprocedural outcomes. Based on preliminary industry-acquired data, it has achieved these goals and appears to be an emergent competitor for the treatment of both focal and complex iliac artery lesions. Keywords: Absolute-Pro®, iliac stent, self-expanding stents, atherosclerotic disease

  5. Feasibility of Using Intravascular Ultrasonography for Assessment of Giant Cavernous Aneurysm after Endovascular Treatment: A Technical Report

    Science.gov (United States)

    Majidi, Shahram; Grigoryan, Mikayel; Tekle, Wondwossen G; Watanabe, Masaki; Qureshi, Adnan I

    2012-01-01

    Introduction Intravascular ultrasonography (IVUS) has been shown as a valuable adjunct imaging tool during endovascular procedures but its value in detection of any recurrence during follow up after endovascular coil embolization of large and giant intracranial aneurysms is not reported. Methods A 41 years old man who had been treated using stent assisted coil embolization for cavernous segment aneurysm of the left internal carotid artery underwent 60 month angiographic follow up. Concurrently, IVUS catheter was advanced under fluoroscopic guidance inside the cavernous portion of the left internal carotid artery. Then IVUS images were used to visualize the stent, coil loops, and aneurysm neck. Results The angiographic images were limited because of superimposition of the aneurysm on the parent vessel in all projections. IVUS images demonstrated that the stent was patent along its whole length and there was no sign of stent deformity or in-stent thrombosis. Loops of the coil were visualized as hyperechoic signals inside the aneurysm and there was no sign of herniated loops of coil inside the stent. Conclusion In this case report, we observed that adjunct use of IVUS can provide valuable information not ascertained by angiography during follow up assessment of coil embolized aneurysm. PMID:22737259

  6. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  7. Risk factors for proximal migration of biliary tube stents.

    Science.gov (United States)

    Kawaguchi, Yoshiaki; Ogawa, Masami; Kawashima, Yohei; Mizukami, Hajime; Maruno, Atsuko; Ito, Hiroyuki; Mine, Tetsuya

    2014-02-07

    To analyze the risk factors for biliary stent migration in patients with benign and malignant strictures. Endoscopic stent placement was performed in 396 patients with bile duct stenosis, at our institution, between June 2003 and March 2009. The indications for bile duct stent implantation included common bile duct stone in 190 patients, malignant lesions in 112, chronic pancreatitis in 62, autoimmune pancreatitis in 14, trauma in eight, surgical complications in six, and primary sclerosing cholangitis (PSC) in four. We retrospectively examined the frequency of stent migration, and analyzed the patient factors (disease, whether endoscopic sphincterotomy was performed, location of bile duct stenosis and diameter of the bile duct) and stent characteristics (duration of stent placement, stent type, diameter and length). Moreover, we investigated retrieval methods for migrated stents and their associated success rates. The frequency of tube stent migration in the total patient population was 3.5%. The cases in which tube stent migration occurred included those with common bile duct stones (3/190; 1.6%), malignant lesions (2/112; 1.8%), chronic pancreatitis (4/62; 6.5%), autoimmune pancreatitis (2/14; 14.3%), trauma (1/8; 12.5%), surgical complications (2/6; 33.3%), and PSC (0/4; 0%). The potential risk factors for migration included bile duct stenosis secondary to benign disease such as chronic pancreatitis and autoimmune pancreatitis (P = 0.030); stenosis of the lower bile duct (P = 0.031); bile duct diameter > 10 mm (P = 0.023); duration of stent placement > 1 mo (P = 0.007); use of straight-type stents (P stents (P stents was successful in all cases. The grasping technique, using a basket or snare, was effective for pig-tailed or thin and straight stents, whereas the guidewire cannulation technique was effective for thick and straight stents. Migration of tube stents within the bile duct is rare but possible, and it is important to determine the risk factors

  8. Randomized Trial of the SMART Stent versus Balloon Angioplasty in Long Superficial Femoral Artery Lesions: The SUPER Study

    International Nuclear Information System (INIS)

    Chalmers, Nicholas; Walker, Paul T.; Belli, Anna-Maria; Thorpe, Anthony P.; Sidhu, Paul S.; Robinson, Graham; Ransbeeck, Mariella van; Fearn, Steven A.

    2013-01-01

    To determine whether primary stenting reduces the rate of restenosis compared with balloon angioplasty alone in the endovascular treatment of long superficial femoral artery lesions; and to assess the effect of treatment on quality of life. A total of 150 patients with superior femoral artery occlusion or severe stenosis of 5–22 cm length from 17 UK centers were randomized to either primary stenting with the SMART stent or balloon angioplasty (i.e., percutaneous transluminal angioplasty, PTA). Bailout stent placement was permitted in case of inadequate result from PTA. The primary end point was restenosis measured by duplex ultrasound at 1 year. Quality-of-life assessments were performed by the EuroQol (EQ)-5D questionnaire. Mean lesion length was 123.0 mm in the stent group and 116.8 mm in the PTA group. A total of 140 (93.3 %) of 150 had total occlusions. At 12 months’ follow-up, restenosis measured by Duplex ultrasound was not significantly different between the stent and PTA groups by intention-to-treat or as-treated analyses: 47.2 versus 43.5 % (p = 0.84) and 40.8 versus 46.7 % (p = 0.68), respectively. There were fewer target lesion revascularizations in patients randomized to stenting, but this did not reach statistical significance (12.5 vs. 20.8 %, p = 0.26). There was no difference in the rate of amputation. Patients in both groups reported improved quality of life. Primary stenting of long lesions in predominantly occluded superficial femoral arteries does not reduce the rate of binary restenosis compared with balloon angioplasty and bailout stenting. Both treatment strategies conferred a meaningful and sustained improvement to the quality of life of patients with severe superficial femoral artery disease.

  9. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  10. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    International Nuclear Information System (INIS)

    Ahmed, Ahmed T.; Mohammed, Khaled; Chehab, Monzer; Brinjikji, Waleed; Hassan Murad, M.; Cloft, Harry; Bjarnason, Haraldur

    2016-01-01

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  11. Comparing Percutaneous Transluminal Angioplasty and Stent Placement for Treatment of Subclavian Arterial Occlusive Disease: A Systematic Review and Meta-Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ahmed T., E-mail: Ahmed.Ahmed1@mayo.edu; Mohammed, Khaled, E-mail: Mohammed.Khaled@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Chehab, Monzer, E-mail: moe.chehab@beumont.edu [Oakland University William Beaumont School of Medicine, Department of Diagnostic Radiology and Molecular Imaging (United States); Brinjikji, Waleed, E-mail: Brinjikji.Waleed@mayo.edu [Mayo Clinic, Department of Radiology (United States); Hassan Murad, M., E-mail: Murad.Mohammad@mayo.edu [Mayo Clinic, Evidence-Based Practice Research Program (United States); Cloft, Harry, E-mail: Cloft.Harry@mayo.edu; Bjarnason, Haraldur, E-mail: Bjarnason.Haraldur@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2016-05-15

    Background and PurposeSubclavian artery occlusive disease (SAOD) is often associated with cerebrovascular symptoms such as subclavian steal syndrome and stroke. We conducted a systematic review and meta-analysis to compare percutaneous transluminal angioplasty (PTA) and stent placement for the treatment of SAOD.Materials and MethodsWe searched Medline, EMBASE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Scopus through October 16, 2014. From each study, we abstracted baseline patient characteristics, study design variables, and outcome data including rates of technical success, primary patency (≤2 and >2 years follow-up), symptom resolution, and complications. Meta-analysis was performed using a random-effects model.ResultsA total of 35 non-comparative studies with 1726 patients were included. Technical success rate was significantly higher in the stent group than the PTA group (92.8 vs 86.8 %, p = 0.007). Long-term primary patency rates (76.9 vs 79.6 %, p = 0.729) and symptom resolution rates (82.2 vs 73.0 %, p = 0.327) were not statistically different. There was no statistically significant difference in the rates of stroke or death.ConclusionStent placement for treatment of SAOD may be associated with higher rates of technical success but similar rates of symptom resolution and long-term outcomes. The confidence in the available estimates is low. Further comparative studies are needed to guide patients and clinicians in shared decision making.

  12. The role of airway stenting in pediatric tracheobronchial obstruction.

    Science.gov (United States)

    Antón-Pacheco, Juan L; Cabezalí, Daniel; Tejedor, Raquel; López, María; Luna, Carmen; Comas, Juan V; de Miguel, Eduardo

    2008-06-01

    Tracheobronchial obstruction is infrequent in the pediatric age group but it is associated with significant morbidity and mortality. The purpose of this study is to review the results of a single institution experience with endoscopic stent placement in children with benign tracheobronchial obstruction, and with special concern on safety and clinical effectiveness. Twenty-one patients with severe airway stenosing disease in which stent placement was performed between 1993 and 2006. Inclusion criteria according to the clinical status were: failure to wean from ventilation, episode of apnea, frequent respiratory infections (>3 pneumonia/year), and severe respiratory distress. Additional criteria for stent placement were: failure of surgical treatment, bronchomalacia, and tracheomalacia refractory to previous tracheostomy. Selection of the type of stent depended on the site of the lesion, the patient's age, and the stent availability when time of presentation. The following variables were retrospectively evaluated: age, type of obstruction, associated malformations, stent properties, technical and clinical success, complications and related reinterventions, outcome and follow-up period. Thirty-three stents were placed in the trachea (n=18) and/or bronchi (n=15) of 21 patients with a median age of 6 months (range, 9 days-19 years). Etiology of the airway obstruction included severe tracheomalacia and/or bronchomalacia in 19 cases (90%), and postoperative tracheal stenosis in two. Twelve children had a total of 20 balloon-expandable metallic stents placed, and 10 had 13 silicone-type stents (one patient had both). In nine patients (42%) more than one device was placed. Stent positioning was technically successful in all but one patient. Clinical improvement was observed in 18 patients (85%) but complications occurred in five of them (27%). Eight patients died during follow-up but only in one case it was related to airway stenting. Thirteen patients (62%) are alive and

  13. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  14. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  15. Aortic arch/elephant trunk procedure with Sienna(TM) graft and endovascular stenting of thoraco-abdominal aorta for treatment of complex chronic dissection.

    Science.gov (United States)

    Wong, Randolph H L; Baghai, Max; Yu, Simon C H; Underwood, Malcolm J

    2013-05-01

    Aneurismal dilatation of the remaining thoracic aorta after ascending aortic interposition grafting for type 'A' aortic dissection is not uncommon. For such complex cases, one treatment option is total arch replacement and elephant trunk procedure with the Sienna(TM) collared graft (Vascutek, Inchinnan, UK) technique followed by a staged thoracic endovascular aortic repair (TEVAR). The video illustrates our technique in a 56-year-old man with an extensive aortic arch and descending thoracic aortic dissecting aneurysm. For the 'open' procedure femoral arterial and venous cannulation was used along with systemic cooling and circulatory arrest at 22 °C. Upon circulatory arrest, the aortic arch was incised and antegrade cerebral perfusion achieved via selective cannulation to the right brachiocephalic and left common carotid artery, keeping flow rates at 10-15 mL/kg/min and perfusion pressure at 50-60 mmHg. Arch replacement with an elephant trunk component was then performed and after completion of the distal aortic anastomosis antegrade perfusion via a side-arm in the graft was started and the operation completed using a variation of the 'sequential' clamping technique to maximize cerebral perfusion. The second endovascular stage was performed two weeks after discharge. Two covered stents were landing from the elephant trunk to the distal descending thoracic aorta, to secure the distal landing a bare stent of was placed to cover the aorta just distal to the origin of the celiac axis. The left subclavian artery was embolised with fibre coils. Post TEVAR angiogram showed no endoleak Although re-operative total arch replacement and elephant trunk procedure and subsequent TEVAR remained a challenging procedure, we believe excellent surgical outcome can be achieved with carefully planned operative strategy.

  16. Flow and wall shear stress characterization after endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model.

    Science.gov (United States)

    Boersen, Johannes T; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H; Ku, David N; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-12-01

    Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is different from a bifurcation with a tapered trajectory of the flow lumen into the two limbs and may induce unfavorable flow conditions. These include low and oscillatory wall shear stress (WSS), linked to atherosclerosis, and high shear rates that may result in thrombosis. An in vitro study was performed to assess the impact of EVAR and EVAS on flow patterns and WSS. Four abdominal aortic aneurysm phantoms were constructed, including three stented models, to study the influence of the flow divider on flow (Endurant [Medtronic, Minneapolis, Minn], AFX [Endologix, Irvine, Calif], and Nellix [Endologix]). Experimental models were tested under physiologic resting conditions, and flow was visualized with laser particle imaging velocimetry, quantified by shear rate, WSS, and oscillatory shear index (OSI) in the suprarenal aorta, renal artery (RA), and common iliac artery. WSS and OSI were comparable for all models in the suprarenal aorta. The RA flow profile in the EVAR models was comparable to the control, but a region of lower WSS was observed on the caudal wall compared with the control. The EVAS model showed a stronger jet flow with a higher shear rate in some regions compared with the other models. Small regions of low WSS and high OSI were found near the distal end of all stents in the common iliac artery compared with the control. Maximum shear rates in each region of interest were well below the pathologic threshold for acute thrombosis. The different stent designs do not influence suprarenal flow. Lower WSS is observed in the caudal wall of the RA after EVAR and a higher shear rate after EVAS. All stented models have a small region of low WSS and high OSI near the distal outflow

  17. Fat-Suppressed Gadolinium-Enhanced Three-Dimensional Magnetic Resonance Angiography Adequately Depicts the Status of Iliac Arteries Following Atherectomy and Stent Placement

    International Nuclear Information System (INIS)

    Amano, Yasuo; Gemma, Kazuhito; Kawamata, Hiroshi; Kumazaki, Tatsuo

    1998-01-01

    Fat-suppressed, three-dimensional magnetic resonance angiography (3D MRA) was performed on nine patients with 11 iliac artery stenoses following atherectomy or stent placement. The MRA accurately depicted continued patency, restenosis, or aneurysm formation when compared with immediate posttreatment conventional arteriography. Therefore MRA is accurate and can be used independently for clinical decision making

  18. Stenting of the cervical internal carotid artery in acute stroke management: The Karolinska experience.

    Science.gov (United States)

    Mpotsaris, Anastasios; Kabbasch, Christoph; Borggrefe, Jan; Gontu, Vamsi; Soderman, Michael

    2017-04-01

    Background Emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy is a routine procedure. Yet, precise indications and clinical safety in this setting remains controversial. Present data for mechanical thrombectomy include few studies with acute stenting of tandem occlusions. We evaluated the feasibility, safety and clinical outcome of this endovascular treatment in a retrospective analysis of all consecutive cases at a comprehensive stroke centre. Methods This was a retrospective analysis of all consecutive patients with acute extracranial carotid artery occlusion including acute dissection or high-grade stenosis and concomitant intracranial large-vessel occlusion treated with emergency carotid stenting and intracranial mechanical thrombectomy between November 2007 and May 2015. Results A total of 63 patients with a median age of 67 years (range 33-84 years) were treated. Of these, 33 (52%) patients had concomitant intravenous thrombolysis with recombinant tissue-type plasminogen activator initially. Median admission National Institutes of Health Stroke Scale was 14 (range 1-29). Median time from stroke onset to recanalization was 408 minutes (range 165-1846 minutes). Procedure time was significantly shorter after intravenous thrombolysis (110 minutes [range 15-202 minutes] vs. 130 minutes [range 60-280 minutes]; p = 0.02). Three (5%) patients experienced post-procedural symptomatic intracerebral haemorrhage. In 55/63 (87%) patients, a score of ≥2b on the Thrombolysis in Cerebral Infarction scale could be achieved. Eight (13%) patients died, five (8%) during the acute phase. A total of 29/63 (46%) patients showed a favourable outcome (modified Rankin Scale score of 0-2) after three months. Conclusions Our single-centre retrospective analysis of emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy demonstrated high

  19. Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

    International Nuclear Information System (INIS)

    Wang Zhongmin; Huang Xunbo; Cao Jun; Huang Gang; Chen Kemin; LIu Yu; Liu Fenju

    2012-01-01

    Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

  20. Feasibility of Angioplasty and Stenting for Abdominal Aortic Lesions Adjacent to Previously Stented Visceral Artery Lesions in Patients with Takayasu Arteritis

    International Nuclear Information System (INIS)

    Joseph, George; George, Paul V.; Pati, Purendra Kumar; Chandy, Sunil Thomas

    2007-01-01

    Two young female patients with Takayasu arteritis presented with symptomatic long-segment abdominal aortic stenosis in the vicinity of previously deployed celiac and renal artery stents that projected markedly into the narrowed aortic lumen. Crushing or distortion of the visceral artery stents during aortic angioplasty was avoided by performing simultaneous or alternating balloon dilatations in the aorta and in the visceral artery stents. Consequently, the visceral artery stents remained patent and shortened longitudinally, allowing unhindered deployment of Wallstents in the adjacent aorta and abolition of a pressure gradient across the aortic lesions. Access to side branches covered by the Wallstent was obtained without difficulty, enabling the performance of balloon dilatation in multiple side branches and ostial stent deployment in a renal artery. These techniques could increase the scope of endovascular therapy in the treatment of patients with Takayasu arteritis

  1. Utilization of self-expanding stents in the treatment of intracranial atherosclerotic disease in the distal small cerebral vessels

    International Nuclear Information System (INIS)

    Turk, Aquilla S.; Niemann, David B.; Aagaard-Kienitz, Beverly; Ahmed, Azam; Brooks, Nathaniel; Levine, Ross L.

    2007-01-01

    Previously, endovascular treatment of stenosis related to intracranial atherosclerosis (ICAD) involving arteries measuring less than 2 mm in diameter was limited. To our knowledge, there are no reports in the literature addressing stent placement for treatment of stenosis in arteries of this size. Four patients aged 33 to 80 years (mean 57.5 years) with medically refractory ICAD underwent angioplasty and stenting of small (<2 mm) distal intracerebral arteries. Vessel location and length of follow-up were anterior cerebral artery (ACA) A1 segment (5 months), ACA A2 segment (18 months), middle cerebral artery M1 segment (18 months), and posterior cerebral artery P1 segment (8 months) with vessel calibers ranging from 1.2 to 1.8 mm. Clinical and imaging follow-up ranged from 5 to 18 months. All procedures were successfully performed without complications. Follow-up out to 18 months demonstrated one vessel that went on to occlusion while the other stented vessel segments remained patent. One patient died 8 months after stenting, but the death was not related to neurological disease. The remaining patients experienced resolution of the presenting symptomatology and remained asymptomatic throughout follow-up. In this small series, stenoses of distal (<2 mm) cerebral arteries were amenable to treatment using new self-expanding stents. We safely and successfully treated four arteries smaller than 2 mm in diameter with newer self-expanding stents. All patients remained clinically asymptomatic. One stent occluded at 5 months and the others remained patent during follow-up. Longer term clinical follow-up is required to determine the durability and viability of this therapy. (orig.)

  2. Tracheal Penetration and Tracheoesophageal Fistula Caused by an Esophageal Self-Expanding Metallic Stent

    Directory of Open Access Journals (Sweden)

    Karan Madan

    2014-01-01

    Full Text Available Tracheal penetration of esophageal self-expanding metallic stents (SEMS with/without tracheoesophageal fistula (TEF formation is a rare occurrence. We report the case of a 66-year-old female patient with advanced esophageal squamous cell carcinoma who had undergone palliative esophageal stenting on three occasions for recurrent esophageal stent obstruction. On evaluation of symptoms of breathing difficulty and aspiration following third esophageal stent placement, tracheal erosion and TEF formation due to the tracheal penetration by esophageal stent were diagnosed. The patient was successfully managed by covered tracheal SEMS placement under flexible bronchoscopy.

  3. Endovascular treatment of intracranial aneurysms with the p64 flow diverter stent: mid-term results in 35 patients with 41 intracranial aneurysms.

    Science.gov (United States)

    Morais, Ricardo; Mine, Benjamin; Bruyère, Pierre Julien; Naeije, Gilles; Lubicz, Boris

    2017-03-01

    The p64 flow diverter (FD) device is a fully resheathable and detachable stent dedicated for endovascular treatment (EVT) of intracranial aneurysms (IAs). We report our mid-term experience with this device. Between January 2015 and February 2016, we retrospectively identified, in our prospectively maintained database, all patients treated with p64 FDs in two institutions. Independent clinical follow-up was performed by a vascular neurologist. Imaging follow-up included a digitalized subtraction angiography (DSA) at 3, 6, and 12 months and a magnetic resonance angiography (MRA) at 12 months. Thirty-nine patients (22 women/17 men; median age 54 years) with 48 IAs (median aneurysm size 6.2 mm; mean neck size 3.4 mm) were identified. All IAs were saccular and unruptured. Failure of safe stent delivery occurred in 15% of cases (7/48 IAs) which were excluded. Transient neurological morbidity occurred in 2/35 patients (5.7%) including one delayed thromboembolic complication. No permanent morbidity or mortality was encountered. Complete aneurysmal occlusion at 3, 6, and 12 months was 20/30 (66.6%), 18/27 (66.6%), and 24/28 (85.7%), respectively. Intra-stent stenosis was observed in 9/29 patients (31%) and classified as moderate in 4/29 (13.7%) and mild in 5/29 patients (17.2%). These stenoses gradually improved over time, with only mild stenoses being identified at 6 months and at 12 months. In our small case series, the p64 FD stent appears safe and effective for EVT of IAs. A high occlusion rate and a low morbidity rate were observed.

  4. Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.

    Science.gov (United States)

    Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I

    2017-04-01

    Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.

  5. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  6. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  7. Suprarenal fixation resulting in intestinal malperfusion after endovascular aortic aneurysm repair.

    Science.gov (United States)

    Siani, Andrea; Accrocca, Federico; De Vivo, Gennaro; Marcucci, Giustino

    2016-05-01

    Superior mesenteric artery (SMA) and coeliac axis (CA) occlusion after endovascular abdominal aneurysm aortic repair (EVAR-AAA), using endograft with suprarenal fixation, are uncommon. However, we are reporting a case of visceral malperfusion, which occurred 7 days after successful EVAR with suprarenal fixation for symptomatic AAA. Endograft metal stent barbs caused severe stenosis of SMA and CA. A successful recovery of SMA was carried out by means of a balloon-expandable stent released through bare metal stent barbs. We believe that an unfavourable anatomy of a proximal aortic neck and visceral aorta may have caused a wrong stent strut deployment with the coverage of CA and SMA. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  8. EW-7197 eluting nano-fiber covered self-expandable metallic stent to prevent granulation tissue formation in a canine urethral model.

    Directory of Open Access Journals (Sweden)

    Kichang Han

    Full Text Available To evaluate an EW-7197-eluting nanofiber-covered stent (NFCS for suppressing granulation tissue formation after stent placement in a canine urethral model.All experiments were approved by the committee of animal research. A total of 12 NFCSs were placed in the proximal and distal urethras of six dogs. Dogs were divided into two groups with 3 dogs each. The control stent (CS group received NFCSs and the drug stent (DS group received EW-7197 (1000 μg-eluting NFCSs. All dogs were sacrificed 8 weeks after stent placement Histologic findings of the stented urethra were compared using the Mann-Whitney U test.Stent placement was technically successful in all dogs without procedure-related complications. On urethrographic analysis, the mean luminal diameter was significantly larger in the DS group than in the CS group at 4 and 8 weeks after stent placement (all p 0.05.The EW-7197-eluting NFCS is effective and safe for suppressing granulation tissue formation after stent placement in a canine urethral model.

  9. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  10. Atherectomy in complex infrainguinal lesions: a review.

    Science.gov (United States)

    Engelberger, S; van den Berg, J C

    2015-02-01

    In the femoropopliteal segment, endovascular revascularization techniques have gained the role as a first line treatment strategy. Nitinol stent placement has improved the short- and mid-term primary patency rates in most lesion types and is therefore widely applied. Stenting has several shortcomings as in-stent restenosis, stent fractures and foreign material being left behind in the vessel. The concept of atherectomy is plaque debulking. This results in a potential reduction of inflation pressure requirements in angioplasty. Stent placement and consecutive in-stent restenosis may be avoided. In this non systematic literature review, the performance of different atherectomy techniques, such as direct atherectomy, orbital atherectomy, laser debulking and rotational atherectomy in the treatment of complex femoropopliteal lesions, including long lesions, moderately to heavily calcified lesions as well as occlusions and in-stent restenosis, has been analyzed.

  11. Endovascular stent-support angioplasty for cerebral venous sinus stenosis

    Directory of Open Access Journals (Sweden)

    Xin-feng LI

    2011-06-01

    Full Text Available Objective To investigate the pathophysiological features of cerebral venous sinus stenosis,and the modus and therapeutic effect of stent-support angioplasty.Methods The clinical data of 36 patients with cerebral venous sinus stenosis,admitted to Neurosurgical Department of General Hospital of PLA from Dec.2001 to Jun.2010,were retrospectively analyzed.Of the 36 cases,10 were males and 26 females,aged from 14 to 57 years with a mean of 37.8 years,and the disease course ranged from 4 days to 9 years.The main clinical manifestations included headache,vomiting,optical visual blurring,and limb weakness with anesthesia in some patients.The diagnosis of all patients was confirmed by digital subtraction angiography,and the results showed that the local stenosis located in right transverse-sigmoid sinus in 21 cases,left transverse-sigmoid sinus in 12 cases,and on both sides in 3 cases.All patients received thrombolytic therapy via carotid artery or a microcatheter inserted in the venous sinus,followed by stent angioplasty of venous sinus.Meanwhile,general anticoagulant and antiplatelet therapy were essential.Results All the 36 patients were successively treated with balloon dilatation and stent angioplasty of venous sinus with exception of 3 cases,who failed because of the circuitous jugular foramen preventing the insertion of the stent.The successful rate was 91.7%.The cerebrospinal fluid pressure of the patients was lowered from 374.7±82.9mmH2O before operation to 230.3±48.1mmH2O after operation.Thirty-three patients were followed-up for 1 month to 8 years by brain angiography and examinations in the outpatient clinic.Among them 32 showed persistent relief of clinical symptoms.The remaining patient presented severe headache and optical visual blurring 1 month after stent implantation,however the symptoms were alleviated obviously after thrombolytic therapy via the carotid artery with adequate anticoagulation.Conclusions Stent angioplasty of venous

  12. Placement of hemoparin-coated stents in the iliac arteries: Early experience and midterm results in 28 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kalmar, Peter I., E-mail: peter.kalmar@medunigraz.at; Portugaller, Rupert H., E-mail: rupert.portugaller@medunigraz.at; Schedlbauer, Peter, E-mail: peter.schedlbauer@klinikum-graz.at; Bohlsen, Dennis, E-mail: dennis.bohlsen@medunigraz.at; Deutschmann, Hannes A., E-mail: hannes.deutschmann@medunigraz.at

    2014-07-15

    Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents.

  13. Placement of hemoparin-coated stents in the iliac arteries: Early experience and midterm results in 28 patients

    International Nuclear Information System (INIS)

    Kalmar, Peter I.; Portugaller, Rupert H.; Schedlbauer, Peter; Bohlsen, Dennis; Deutschmann, Hannes A.

    2014-01-01

    Purpose: Aim was to determine immediate results and mid-term outcome of the hemoparin-coated (HC) stainless-steel stent (camouflage coating) in the treatment of occlusive lesions of the iliac arteries. Materials and methods: Twenty-eight patients were prospectively treated with the use of a HC stent between January 2007 and March 2010. Clinical examination and color-doppler ultrasound were performed at 1, 3, 6 and 12 months, CT angiography (CTA) or MR angiography (MRA) at 12 months. Indication for treatment was a high-grade stenosis of the common iliac and/or external iliac artery. Results: Successful placement was achieved in all patients. Significant decrease in translesional pressure gradient (>10 mmHg) was measured in 27 patients (96%). In one patient, proximal dissection occurred without flow limitation. A minor complication (small access site hematoma) occurred in one patient (4%). Two patients (7%) were lost to follow-up. After 12 months, stent patency in CTA, MRA and ultrasound was 100%. 20 patients (77%) experienced an initial improvement of at least one clinical stage. In one patient (4%), mild intimal hyperplasia without significant stenosis was observed. In three patients (12%), proximal or distal stenosis occurred. A non-significant increase of mean ankle-brachial index (ABI) after treatment was measured (0.85 ± 0.27 vs. 0.75 ± 0.22, respectively; p = 0.328). Conclusions: The use of HC stents in patients with iliac artery occlusive disease may lead to a lower rate of intimal hyperplasia and thus to increased patency rates even in heavily calcified vessels. However, large-scale prospective trials have to be performed to evaluate the long-term patency rates of the HC coated stents

  14. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    Energy Technology Data Exchange (ETDEWEB)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro [Kyoto Second Red Cross Hospital, Kyoto (Japan)

    2012-02-15

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  15. Palliation of Malignant Upper Gastrointestinal Obstruction with Self-Expandable Metal Stent

    International Nuclear Information System (INIS)

    Morikawa, Soichiro; Suzuki, Azumi; Nakase, Kojiro; Yasuda, Kenjiro

    2012-01-01

    To assess the technical success, ability to eat, complications and clinical outcomes of patients with self-expandable metal stent (SEMS) placed for malignant upper gastrointestinal (GI) obstruction. Data was collected retrospectively on patients who underwent SEMS placement for palliation of malignant upper GI obstruction by reviewing hospital charts from June 1998 to May 2011. Main outcome measurements were technical success, gastric outlet obstruction scoring system (GOOSS) score before and after treatment, complications, and survival. A total of 82 patients underwent SEMS placement with malignant upper GI obstruction. The initial SEMS placement was successful in 77 patients (93.9%). The mean GOOSS score was 0.56 before stenting and 1.92 (p < 0.001) after treatment. Complications arose in 12 patients (14.6%): stent migration in 1 patient (1.2%), perforation in 1 (1.2%), and obstruction of stent due to tumor ingrowth in 10 (12.2%). The median survival time after stenting was 52 days (6-445). SEMS placement is an effective and safe treatment for palliation of malignant upper GI obstruction. It provides lasting relief in dysphagia and improves the QOL of patients.

  16. Management of hilar bile duct carcinoma with high-dose radiotherapy and expandable metallic stent placement

    International Nuclear Information System (INIS)

    Saito, Hiroya; Takamura, Akio

    2000-01-01

    This article describes our experience with high-dose radiotherapy in combination with the placement of expandable metallic stents (EMS) in the management of hilar bile duct carcinoma. Between 1988 and 1999, 107 consecutive patients with hilar bile duct carcinoma were treated with EMS placement either alone or in combination with high-dose radiotherapy. External beam radiotherapy (EBRT) was indicated in 101 patients, and in 86 this was combined with intraluminal 192 Ir irradiation (ILRT, 59-98 Gy) EMS were placed after the completion of radiotherapy. The 1-, 2-, 3-, and 5-year actuarial survival rates for the radiotherapy group were 66.4%, 23.4%, 15.6%, 7.8%, respectively, and the 1- and 2-year actuarial survival rates for the nonradiotherapy group were 66.4% and 0%, respectively. The placement of EMS was useful for the early establishment of an internal bile passage in radically irradiated patients and the 1-, 2-, 3-, and 5-year actuarial patency rates for the radiotherapy group were 56.3%, 45.3%, 35.2%, and 23.4%, respectively, and the 1- and 2-year actuarial patency rates for the non radiotherapy group were 50.0% and 0% respectively. High-dose radiotherapy, consisting of ILRT and EBRT, appears to be feasible in the management of hilar bile duct carcinoma, and it offers a survival advantage for patients no suited for surgical resection. The placement of EMS assists the internal bile flow and lengthens survival after high-dose radiotherapy. (author)

  17. Treatment of esophagopleural fistulas using covered retrievable expandable metallic stents.

    Science.gov (United States)

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Kyung Rae; Park, Jung-Hoon; Kim, Jin Hyoung; Song, Ho-Young

    2014-04-01

    To evaluate the clinical efficacy of placement of covered retrievable expandable metallic stents for esophagopleural fistulas (EPFs). During the period 1997-2013, nine patients with EPF were treated using covered retrievable expandable metallic stents. The underlying causes of EPF were esophageal carcinoma (n = 6), lung cancer (n = 2), and postoperative empyema for Boerhaave syndrome (n = 1). Technical success was achieved in eight patients (88.9%). In one patient, incomplete EPF closure was due to incomplete stent expansion. Clinical success, defined as complete EPF closure within 7 days, was achieved in five patients (55.6%). Overall fistula persistence (n = 1) or reopening (n = 4) occurred in five patients (55.6%) 0-15 days after stent placement. The causes of reopening were due to the gap between the stent and the esophagus (n = 3) or stent migration (n = 1). For fistula persistence or reopening, additional interventional management, such as gastrostomy, stent removal, or stent reinsertion, was performed. Stent migration occurred as a complication in one patient with EPF from a benign cause secondary to postoperative empyema. In the eight patients who died during the follow-up period, the mean and median survival times were 78.8 days and 46 days, respectively. Placement of a covered expandable metallic esophageal stent for the palliative treatment of EPF is technically feasible, although the rate of clinical success was poor secondary to fistula persistence or reopening. Fistula reopening was caused by the gap between the stent and the esophagus or by stent migration, and additional interventional treatment was useful to ensure enteral nutritional support. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  18. Carotid angioplasty and stenting for symptomatic carotid kinking combined with stenosis

    Directory of Open Access Journals (Sweden)

    JIANG Xue-li

    2013-03-01

    Full Text Available Background Carotid endarterectomy (CEA is currently the preferred treatment for severe carotid kinking and stenosis. Kinking is generally believed to be a relative contraindication for endovascular stent placement. This article aims to study the necessity, feasibility and security of carotid angioplasty and stenting (CAS for symptomatic carotid kinking combined with stenosis, and summarize clinical experience of this disease according to therapeutic results. Methods Twenty-two cases with symptomatic carotid kinking and high-grade stenosis demonstrated by digital subtraction angiography (DSA were performed CAS. Their clinical manifestations, imaging features, procedure safety and follow-up data were collected and retrospectively analyzed. All patients understood CEA and voluntarily received CAS. Results Twenty-two cases with carotid kinking and stenosis were all successfully performed CAS (the success rate was 100% without stent-related disability or mortality. Twenty-four self-expandable stents were implanted. The mean degree of stenosis was reduced from 85.63%before stenting to 11.25% after stenting and the angles of kinking were improved from 120° (Metz' category. During the period of hospitalization, no transient ischemic attack (TIA or cerebral infarction occurred, and the clinical symptoms and signs of ischemia, such as dizziness and headache, were improved or disappeared. Besides, no permenant complications or deaths happened. All cases were followed up from 6 to 72 months, among whom 1 patient experienced contralateral carotid TIA, and 2 patients experienced ipsilateral carotid TIA (one indicated aspirin resistance in platelet aggregation test and the other showed restenosis in DSA. Computed tomography angiography (CTA of 10 patients and Duplex scan of 7 patients during the follow-up demonstrated carotid in good morphology and fluent blood flow, without kinking or restenosis. Conclusion CAS is a feasible and safe therapeutic method and

  19. Temporary metal internal stent dilation for colorectal obstruction and effect on operation methods

    International Nuclear Information System (INIS)

    Chen Niwei; Cheng Yingsheng; Fan Youben; Jin Huimin; Xu Huimin

    2005-01-01

    Objective: To explore the methods and clinical value of temporary internal metal stent through endoscopy under X ray control for treating patients with malignant colorectal obstruction. Methods: 27 patients with malignant colorectal obstruction were treated by temporary metallic internal stent placement via endoscopy under the X ray guidance. Results: 27 patients with colorectal obstruction symptoms were all got rid of the trouble within 48 hours after the stent placement. Selective stage I colorectal cancer resection and anastomosis were performed after bowel preparation. Conclusions: Metallic internal stent placement can loosen the colorectal obstructive symptoms with higher successful rate via endoscopy under X ray control and furthermore for promotion of stage I colorectal cancer resection and anastomosis. (authors)

  20. On the Mechanical Properties and Microstructure of Nitinol forBiomedical Stent Applications

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Scott W. [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    This dissertation was motivated by the alarming number of biomedical device failures reported in the literature, coupled with the growing trend towards the use of Nitinol for endovascular stents. The research is aimed at addressing two of the primary failure modes in Nitinol endovascular stents: fatigue-crack growth and overload fracture. The small dimensions of stents, coupled with their complex geometries and variability among manufacturers, make it virtually impossible to determine generic material constants associated with specific devices. Instead, the research utilizes a hybrid of standard test techniques (fracture mechanics and x-ray micro-diffraction) and custom-designed testing apparatus for the determination of the fracture properties of specimens that are suitable representations of self-expanding Nitinol stents. Specifically, the role of texture (crystallographic alignment of atoms) and the austenite-to-martensite phase transformation on the propagation of cracks in Nitinol was evaluated under simulated body conditions and over a multitude of stresses and strains. The results determined through this research were then used to create conservative safe operating and inspection criteria to be used by the biomedical community for the determination of specific device vulnerability to failure by fracture and/or fatigue.