WorldWideScience

Sample records for endoscopic image-processing technology

  1. Computer-based endoscopic image-processing technology for endourology and laparoscopic surgery

    International Nuclear Information System (INIS)

    Igarashi, Tatsuo; Suzuki, Hiroyoshi; Naya, Yukio

    2009-01-01

    Endourology and laparoscopic surgery are evolving in accordance with developments in instrumentation and progress in surgical technique. Recent advances in computer and image-processing technology have enabled novel images to be created from conventional endoscopic and laparoscopic video images. Such technology harbors the potential to advance endourology and laparoscopic surgery by adding new value and function to the endoscope. The panoramic and three-dimensional images created by computer processing are two outstanding features that can address the shortcomings of conventional endoscopy and laparoscopy, such as narrow field of view, lack of depth cue, and discontinuous information. The wide panoramic images show an anatomical map' of the abdominal cavity and hollow organs with high brightness and resolution, as the images are collected from video images taken in a close-up manner. To assist in laparoscopic surgery, especially in suturing, a three-dimensional movie can be obtained by enhancing movement parallax using a conventional monocular laparoscope. In tubular organs such as the prostatic urethra, reconstruction of three-dimensional structure can be achieved, implying the possibility of a liquid dynamic model for assessing local urethral resistance in urination. Computer-based processing of endoscopic images will establish new tools for endourology and laparoscopic surgery in the near future. (author)

  2. Endoscopes with latest technology and concept.

    Science.gov (United States)

    Gotoh

    2003-09-01

    Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.

  3. The combination design for open and endoscopic surgery using fluorescence molecular imaging technology

    Science.gov (United States)

    Mao, Yamin; Jiang, Shixin; Ye, Jinzuo; An, Yu; Yang, Xin; Chi, Chongwei; Tian, Jie

    2015-03-01

    For clinical surgery, it is still a challenge to objectively determine tumor margins during surgery. With the development of medical imaging technology, fluorescence molecular imaging (FMI) method can provide real-time intraoperative tumor margin information. Furthermore, surgical navigation system based on FMI technology plays an important role for the aid of surgeons' precise tumor margin decision. However, detection depth is the most limitation exists in the FMI technique and the method convenient for either macro superficial detection or micro deep tissue detection is needed. In this study, we combined advantages of both open surgery and endoscopic imaging systems with FMI technology. Indocyanine green (ICG) experiments were performed to confirm the feasibility of fluorescence detection in our system. Then, the ICG signal was photographed in the detection area with our system. When the system connected with endoscope lens, the minimum quantity of ICG detected by our system was 0.195 ug. For aspect of C mount lens, the sensitivity of ICG detection with our system was 0.195ug. Our experiments results proved that it was feasible to detect fluorescence images with this combination method. Our system shows great potential in the clinical applications of precise dissection of various tumors

  4. [PACS-based endoscope image acquisition workstation].

    Science.gov (United States)

    Liu, J B; Zhuang, T G

    2001-01-01

    A practical PACS-based Endoscope Image Acquisition Workstation is here introduced. By a Multimedia Video Card, the endoscope video is digitized and captured dynamically or statically into computer. This workstation realizes a variety of functions such as the endoscope video's acquisition and display, as well as the editing, processing, managing, storage, printing, communication of related information. Together with other medical image workstation, it can make up the image sources of PACS for hospitals. In addition, it can also act as an independent endoscopy diagnostic system.

  5. Identification of early cancerous lesion of esophagus with endoscopic images by hyperspectral image technique (Conference Presentation)

    Science.gov (United States)

    Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen

    2016-03-01

    This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.

  6. endoscope-i: an innovation in mobile endoscopic technology transforming the delivery of patient care in otolaryngology.

    Science.gov (United States)

    Mistry, N; Coulson, C; George, A

    2017-11-01

    Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.

  7. Implementation of real-time digital endoscopic image processing system

    Science.gov (United States)

    Song, Chul Gyu; Lee, Young Mook; Lee, Sang Min; Kim, Won Ky; Lee, Jae Ho; Lee, Myoung Ho

    1997-10-01

    Endoscopy has become a crucial diagnostic and therapeutic procedure in clinical areas. Over the past four years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholecystectomy, pelviscopic endometriosis, and surgical arthroscopy. In this study, we developed a computer system, which is composed of a frame grabber, a sound board, a VCR control board, a LAN card and EDMS. Also, computer system controls peripheral instruments such as a color video printer, a video cassette recorder, and endoscopic input/output signals. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards; namely Microsoft Windows as an operating system, TCP/IP as a network protocol and a time sequential database that handles both images and speech. For the purpose of data storage, we used MOD and CD- R. Digital endoscopic system was designed to be able to store, recreate, change, and compress signals and medical images. Computerized endoscopy enables us to generate and manipulate the original visual document, making it accessible to a virtually unlimited number of physicians.

  8. Terahertz endoscopic imaging for colorectal cancer detection: Current status and future perspectives.

    Science.gov (United States)

    Doradla, Pallavi; Joseph, Cecil; Giles, Robert H

    2017-08-16

    Terahertz (THz) imaging is progressing as a robust platform for myriad applications in the field of security, health, and material science. The THz regime, which comprises wavelengths spanning from microns to millimeters, is non-ionizing and has very low photon energy: Making it inherently safe for biological imaging. Colorectal cancer is one of the most common causes of death in the world, while the conventional screening and standard of care yet relies exclusively on the physician's experience. Researchers have been working on the development of a flexible THz endoscope, as a potential tool to aid in colorectal cancer screening. This involves building a single-channel THz endoscope, and profiling the THz response from colorectal tissue, and demonstrating endogenous contrast levels between normal and diseased tissue when imaging in reflection modality. The current level of contrast provided by the prototype THz endoscopic system represents a significant step towards clinical endoscopic application of THz technology for in-vivo colorectal cancer screening. The aim of this paper is to provide a short review of the recent advances in THz endoscopic technology and cancer imaging. In particular, the potential of single-channel THz endoscopic imaging for colonic cancer screening will be highlighted.

  9. [Digital imaging and robotics in endoscopic surgery].

    Science.gov (United States)

    Go, P M

    1998-05-23

    The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).

  10. Endoscopic and keyhole endoscope-assisted neurosurgical approaches: a qualitative survey on technical challenges and technological solutions.

    Science.gov (United States)

    Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2014-10-01

    The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.

  11. Image acquisition in laparoscopic and endoscopic surgery

    Science.gov (United States)

    Gill, Brijesh S.; Georgeson, Keith E.; Hardin, William D., Jr.

    1995-04-01

    Laparoscopic and endoscopic surgery rely uniquely on high quality display of acquired images, but a multitude of problems plague the researcher who attempts to reproduce such images for educational purposes. Some of these are intrinsic limitations of current laparoscopic/endoscopic visualization systems, while others are artifacts solely of the process used to acquire and reproduce such images. Whatever the genesis of these problems, a glance at current literature will reveal the extent to which endoscopy suffers from an inability to reproduce what the surgeon sees during a procedure. The major intrinsic limitation to the acquisition of high-quality still images from laparoscopic procedures lies in the inability to couple directly a camera to the laparoscope. While many systems have this capability, this is useful mostly for otolaryngologists, who do not maintain a sterile field around their scopes. For procedures in which a sterile field must be maintained, one trial method has been to use a beam splitter to send light both to the still camera and the digital video camera. This is no solution, however, since this results in low quality still images as well as a degradation of the image that the surgeon must use to operate, something no surgeon tolerates lightly. Researchers thus must currently rely on other methods for producing images from a laparoscopic procedure. Most manufacturers provide an optional slide or print maker that provides a hardcopy output from the processed composite video signal. The results achieved from such devices are marginal, to say the least. This leaves only one avenue for possible image production, the videotape record of an endoscopic or laparoscopic operation. Video frame grabbing is at least a problem to which industry has applied considerable time and effort to solving. Our own experience with computerized enhancement of videotape frames has been very promising. Computer enhancement allows the researcher to correct several of the

  12. Correcting the Chromatic Aberration in Barrel Distortion of Endoscopic Images

    Directory of Open Access Journals (Sweden)

    Y. M. Harry Ng

    2003-04-01

    Full Text Available Modern endoscopes offer physicians a wide-angle field of view (FOV for minimally invasive therapies. However, the high level of barrel distortion may prevent accurate perception of image. Fortunately, this kind of distortion may be corrected by digital image processing. In this paper we investigate the chromatic aberrations in the barrel distortion of endoscopic images. In the past, chromatic aberration in endoscopes is corrected by achromatic lenses or active lens control. In contrast, we take a computational approach by modifying the concept of image warping and the existing barrel distortion correction algorithm to tackle the chromatic aberration problem. In addition, an error function for the determination of the level of centroid coincidence is proposed. Simulation and experimental results confirm the effectiveness of our method.

  13. Ultrahigh sensitivity endoscopic camera using a new CMOS image sensor: providing with clear images under low illumination in addition to fluorescent images.

    Science.gov (United States)

    Aoki, Hisae; Yamashita, Hiromasa; Mori, Toshiyuki; Fukuyo, Tsuneo; Chiba, Toshio

    2014-11-01

    We developed a new ultrahigh-sensitive CMOS camera using a specific sensor that has a wide range of spectral sensitivity characteristics. The objective of this study is to present our updated endoscopic technology that has successfully integrated two innovative functions; ultrasensitive imaging as well as advanced fluorescent viewing. Two different experiments were conducted. One was carried out to evaluate the function of the ultrahigh-sensitive camera. The other was to test the availability of the newly developed sensor and its performance as a fluorescence endoscope. In both studies, the distance from the endoscopic tip to the target was varied and those endoscopic images in each setting were taken for further comparison. In the first experiment, the 3-CCD camera failed to display the clear images under low illumination, and the target was hardly seen. In contrast, the CMOS camera was able to display the targets regardless of the camera-target distance under low illumination. Under high illumination, imaging quality given by both cameras was quite alike. In the second experiment as a fluorescence endoscope, the CMOS camera was capable of clearly showing the fluorescent-activated organs. The ultrahigh sensitivity CMOS HD endoscopic camera is expected to provide us with clear images under low illumination in addition to the fluorescent images under high illumination in the field of laparoscopic surgery.

  14. Design of a modified endoscope illuminator for spectral imaging of colorectal tissues

    Science.gov (United States)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2017-02-01

    The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.

  15. Image segmentation of pyramid style identifier based on Support Vector Machine for colorectal endoscopic images.

    Science.gov (United States)

    Okamoto, Takumi; Koide, Tetsushi; Sugi, Koki; Shimizu, Tatsuya; Anh-Tuan Hoang; Tamaki, Toru; Raytchev, Bisser; Kaneda, Kazufumi; Kominami, Yoko; Yoshida, Shigeto; Mieno, Hiroshi; Tanaka, Shinji

    2015-08-01

    With the increase of colorectal cancer patients in recent years, the needs of quantitative evaluation of colorectal cancer are increased, and the computer-aided diagnosis (CAD) system which supports doctor's diagnosis is essential. In this paper, a hardware design of type identification module in CAD system for colorectal endoscopic images with narrow band imaging (NBI) magnification is proposed for real-time processing of full high definition image (1920 × 1080 pixel). A pyramid style image segmentation with SVMs for multi-size scan windows, which can be implemented on an FPGA with small circuit area and achieve high accuracy, is proposed for actual complex colorectal endoscopic images.

  16. Application of Java technology in radiation image processing

    International Nuclear Information System (INIS)

    Cheng Weifeng; Li Zheng; Chen Zhiqiang; Zhang Li; Gao Wenhuan

    2002-01-01

    The acquisition and processing of radiation image plays an important role in modern application of civil nuclear technology. The author analyzes the rationale of Java image processing technology which includes Java AWT, Java 2D and JAI. In order to demonstrate applicability of Java technology in field of image processing, examples of application of JAI technology in processing of radiation images of large container have been given

  17. 4-mm-diameter three-dimensional imaging endoscope with steerable camera for minimally invasive surgery (3-D-MARVEL).

    Science.gov (United States)

    Bae, Sam Y; Korniski, Ronald J; Shearn, Michael; Manohara, Harish M; Shahinian, Hrayr

    2017-01-01

    High-resolution three-dimensional (3-D) imaging (stereo imaging) by endoscopes in minimally invasive surgery, especially in space-constrained applications such as brain surgery, is one of the most desired capabilities. Such capability exists at larger than 4-mm overall diameters. We report the development of a stereo imaging endoscope of 4-mm maximum diameter, called Multiangle, Rear-Viewing Endoscopic Tool (MARVEL) that uses a single-lens system with complementary multibandpass filter (CMBF) technology to achieve 3-D imaging. In addition, the system is endowed with the capability to pan from side-to-side over an angle of [Formula: see text], which is another unique aspect of MARVEL for such a class of endoscopes. The design and construction of a single-lens, CMBF aperture camera with integrated illumination to generate 3-D images, and the actuation mechanism built into it is summarized.

  18. Towards automated visual flexible endoscope navigation.

    Science.gov (United States)

    van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J

    2013-10-01

    The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.

  19. Fundus imaging with a nasal endoscope

    Directory of Open Access Journals (Sweden)

    P Mahesh Shanmugam

    2015-01-01

    Full Text Available Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

  20. Neuro-fuzzy Classification System for Wireless-Capsule Endoscopic Images

    OpenAIRE

    Vassilis S. Kodogiannis; John N. Lygouras

    2008-01-01

    In this research study, an intelligent detection system to support medical diagnosis and detection of abnormal lesions by processing endoscopic images is presented. The images used in this study have been obtained using the M2A Swallowable Imaging Capsule - a patented, video color-imaging disposable capsule. Schemes have been developed to extract texture features from the fuzzy texture spectra in the chromatic and achromatic domains for a selected region of interest from ...

  1. Endoscopic Tri-Modal Imaging (ETMI With Optical Magnification in the Detection of Barrett's Early Neoplasia

    Directory of Open Access Journals (Sweden)

    Sarmed S. Sami

    2014-01-01

    Full Text Available Early lesion detection and characterisation is vital to ensure accurate management in patients with gastrointestinal neoplasia. Endoscopic Tri-modal Imaging (ETMI technology has been shown to improve the targeted detection of early dysplastic lesions in Barrett's Oesophagus, but these results were not confirmed in non-expert hands [1]. This technology incorporates high resolution while light endoscopy (HRE, Auto Fluorescence Imaging (AFI and Narrow Band Imaging (NBI in one endoscope. The mucosa is first inspected with HRE, and then AFI is switched on to help in highlighting any suspicious areas in the mucosa [2]. These areas can be further examined by switching to NBI mode with magnification which helps to characterise mucosal patterns and identify early neoplasia [3].

  2. Development of an integrated filing system for endoscopic images.

    Science.gov (United States)

    Fujino, M A; Ikeda, M; Yamamoto, Y; Kinose, T; Tachikawa, H; Morozumi, A; Sano, S; Kojima, Y; Nakamura, T; Kawai, T

    1991-01-01

    A new integrated filing system for endoscopic images has been developed, comprising a main image filing system and subsystems located at different stations. A hybrid filing system made up of both digital and analog filing devices was introduced to construct this system that combines the merits of the two filing methods. Each subsystem provided with a video processor, is equipped with a digital filing device, and routine images were recorded in the analog image filing device of the main system. The use of a multi-input adapter enabled simultaneous input of analog images from up to 8 video processors. Recorded magneto-optical disks make it possible to recall the digital images at any station in the hospital; the disks are copied without image degradation and also utilised for image processing. This system promises reliable storage and integrated, efficient management of endoscopic information. It also costs less to install than the so-called PACS (picture archiving and communication system), which connects all the stations of the hospital using optical fiber cables.

  3. Integrated biophotonics in endoscopic oncology

    Science.gov (United States)

    Muguruma, Naoki; DaCosta, Ralph S.; Wilson, Brian C.; Marcon, Norman E.

    2009-02-01

    Gastrointestinal endoscopy has made great progress during last decade. Diagnostic accuracy can be enhanced by better training, improved dye-contrast techniques method, and the development of new image processing technologies. However, diagnosis using conventional endoscopy with white-light optical imaging is essentially limited by being based on morphological changes and/or visual attribution: hue, saturation and intensity, interpretation of which depends on the endoscopist's eye and brain. In microlesions in the gastrointestinal tract, we still rely ultimately on the histopathological diagnosis from biopsy specimens. Autofluorescence imaging system has been applied for lesions which have been difficult to morphologically recognize or are indistinct with conventional endoscope, and this approach has potential application for the diagnosis of dysplastic lesions and early cancers in the gastrointestinal tract, supplementing the information from white light endoscopy. This system has an advantage that it needs no administration of a photosensitive agent, making it suitable as a screening method for the early detection of neoplastic tissues. Narrow band imaging (NBI) is a novel endoscopic technique which can distinguish neoplastic and non-neoplastic lesions without chromoendoscopy. Magnifying endoscopy in combination with NBI has an obvious advantage, namely analysis of the epithelial pit pattern and the vascular network. This new technique allows a detailed visualization in early neoplastic lesions of esophagus, stomach and colon. However, problems remain; how to combine these technologies in an optimum diagnostic strategy, how to apply them into the algorithm for therapeutic decision-making, and how to standardize several classifications surrounding them. 'Molecular imaging' is a concept representing the most novel imaging methods in medicine, although the definition of the word is still controversial. In the field of gastrointestinal endoscopy, the future of

  4. Endoscopic hyperspectral imaging: light guide optimization for spectral light source

    Science.gov (United States)

    Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.

    2018-02-01

    Hyperspectral imaging (HSI) is a technology used in remote sensing, food processing and documentation recovery. Recently, this approach has been applied in the medical field to spectrally interrogate regions of interest within respective substrates. In spectral imaging, a two (spatial) dimensional image is collected, at many different (spectral) wavelengths, to sample spectral signatures from different regions and/or components within a sample. Here, we report on the use of hyperspectral imaging for endoscopic applications. Colorectal cancer is the 3rd leading cancer for incidences and deaths in the US. One factor of severity is the miss rate of precancerous/flat lesions ( 65% accuracy). Integrating HSI into colonoscopy procedures could minimize misdiagnosis and unnecessary resections. We have previously reported a working prototype light source with 16 high-powered light emitting diodes (LEDs) capable of high speed cycling and imaging. In recent testing, we have found our current prototype is limited by transmission loss ( 99%) through the multi-furcated solid light guide (lightpipe) and the desired framerate (20-30 fps) could not be achieved. Here, we report on a series of experimental and modeling studies to better optimize the lightpipe and the spectral endoscopy system as a whole. The lightpipe was experimentally evaluated using an integrating sphere and spectrometer (Ocean Optics). Modeling the lightpipe was performed using Monte Carlo optical ray tracing in TracePro (Lambda Research Corp.). Results of these optimization studies will aid in manufacturing a revised prototype with the newly designed light guide and increased sensitivity. Once the desired optical output (5-10 mW) is achieved then the HIS endoscope system will be able to be implemented without adding onto the procedure time.

  5. Averaged subtracted polarization imaging for endoscopic diagnostics of surface microstructures on translucent mucosae

    Science.gov (United States)

    Kanamori, Katsuhiro

    2016-07-01

    An endoscopic image processing technique for enhancing the appearance of microstructures on translucent mucosae is described. This technique employs two pairs of co- and cross-polarization images under two different linearly polarized lights, from which the averaged subtracted polarization image (AVSPI) is calculated. Experiments were then conducted using an acrylic phantom and excised porcine stomach tissue using a manual experimental setup with ring-type lighting, two rotating polarizers, and a color camera; better results were achieved with the proposed method than with conventional color intensity image processing. An objective evaluation method that uses texture analysis was developed and used to evaluate the enhanced microstructure images. This paper introduces two types of online, rigid-type, polarimetric endoscopic implementations using a polarized ring-shaped LED and a polarimetric camera. The first type uses a beam-splitter-type color polarimetric camera, and the second uses a single-chip monochrome polarimetric camera. Microstructures on the mucosa surface were enhanced robustly with these online endoscopes regardless of the difference in the extinction ratio of each device. These results show that polarimetric endoscopy using AVSPI is both effective and practical for hardware implementation.

  6. Image processing technology for nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Beom; Kim, Woong Ki; Park, Soon Young

    1993-05-01

    Digital image processing technique is being actively studied since microprocessors and semiconductor memory devices have been developed in 1960's. Now image processing board for personal computer as well as image processing system for workstation is developed and widely applied to medical science, military, remote inspection, and nuclear industry. Image processing technology which provides computer system with vision ability not only recognizes nonobvious information but processes large information and therefore this technique is applied to various fields like remote measurement, object recognition and decision in adverse environment, and analysis of X-ray penetration image in nuclear facilities. In this report, various applications of image processing to nuclear facilities are examined, and image processing techniques are also analysed with the view of proposing the ideas for future applications. (Author)

  7. Virtualized endoscope system. An application of virtual reality technology to diagnostic aid

    International Nuclear Information System (INIS)

    Mori, Kensaku; Urano, Akihiro; Toriwaki, Jun-ichiro; Hasegawa, Jun-ichi; Anno, Hirofumi; Katada, Kazuhiro.

    1996-01-01

    In this paper we propose a new medical image processing system called 'Virtualized Endoscope System (VES)', which can examine the inside of a virtualized human body. The virtualized human body is a 3-D digital image which is taken by such as X-ray CT scanner or MRI scanner. VES consists of three modules; (1) imaging, (2) segmentation and reconstruction and (3) interactive operation. The interactive operation module has following three major functions; (a) display of, (b) measurement from, and (c) manipulation to the virtualized human body. The user of the system can observe freely both the inside and the outside of a target organ from any point and any direction freely, and can perform necessary measurement interactively concerning angle and length at any time during observation. VES enables to observe repeatedly an area where the real endoscope can not enter without pain from any direction which the real endoscope can not. We applied this system to real 3-D X-ray CT images and obtained good result. (author)

  8. Polymer Optical Fibre Sensors for Endoscopic Opto-Acoustic Imaging

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet

    2015-01-01

    in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference...... is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared...... and a higher resolution at small sizes. Furthermore, micro structured polymer optical fibres offer over 12 times the sensitivity of silica fibre. We present a polymer fibre Bragg grating ultrasound detector with a core diameter of 125 microns. We discuss the ultrasonic signals received and draw conclusions...

  9. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  10. Chromaticity based smoke removal in endoscopic images

    Science.gov (United States)

    Tchaka, Kevin; Pawar, Vijay M.; Stoyanov, Danail

    2017-02-01

    In minimally invasive surgery, image quality is a critical pre-requisite to ensure a surgeons ability to perform a procedure. In endoscopic procedures, image quality can deteriorate for a number of reasons such as fogging due to the temperature gradient after intra-corporeal insertion, lack of focus and due to smoke generated when using electro-cautery to dissect tissues without bleeding. In this paper we investigate the use of vision processing techniques to remove surgical smoke and improve the clarity of the image. We model the image formation process by introducing a haze medium to account for the degradation of visibility. For simplicity and computational efficiency we use an adapted dark-channel prior method combined with histogram equalization to remove smoke artifacts to recover the radiance image and enhance the contrast and brightness of the final result. Our initial results on images from robotic assisted procedures are promising and show that the proposed approach may be used to enhance image quality during surgery without additional suction devices. In addition, the processing pipeline may be used as an important part of a robust surgical vision pipeline that can continue working in the presence of smoke.

  11. The Role of Adjunct Imaging in Endoscopic Detection of Dysplasia in Barrett's Esophagus.

    Science.gov (United States)

    Kandel, Pujan; Wallace, Michael B

    2017-07-01

    Advances in imaging technologies have demonstrated promise in early detection of dysplasia and cancer in Barrett's esophagus (BE). Optical chromoendoscopy, dye-based chromoendoscopy, and novel technologies have provided the opportunity to visualize the cellular and subcellular structures. Only narrow-band imaging and acetic acid chromoendoscopy have reached benchmarks for clinical use. Volumetric laser endomicroscopy and molecular imaging are not established for routine use. Best practice in management of BE should be focused on careful endoscopic examination, resection, or ablation of the entire abnormal lesion, as well as the use of available imaging technique that has good diagnostic accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Excitation-scanning hyperspectral imaging system for microscopic and endoscopic applications

    Science.gov (United States)

    Mayes, Sam A.; Leavesley, Silas J.; Rich, Thomas C.

    2016-04-01

    Current microscopic and endoscopic technologies for cancer screening utilize white-light illumination sources. Hyper-spectral imaging has been shown to improve sensitivity while retaining specificity when compared to white-light imaging in both microscopy and in vivo imaging. However, hyperspectral imaging methods have historically suffered from slow acquisition times due to the narrow bandwidth of spectral filters. Often minutes are required to gather a full image stack. We have developed a novel approach called excitation-scanning hyperspectral imaging that provides 2-3 orders of magnitude increased signal strength. This reduces acquisition times significantly, allowing for live video acquisition. Here, we describe a preliminary prototype excitation-scanning hyperspectral imaging system that can be coupled with endoscopes or microscopes for hyperspectral imaging of tissues and cells. Our system is comprised of three subsystems: illumination, transmission, and imaging. The illumination subsystem employs light-emitting diode arrays to illuminate at different wavelengths. The transmission subsystem utilizes a unique geometry of optics and a liquid light guide. Software controls allow us to interface with and control the subsystems and components. Digital and analog signals are used to coordinate wavelength intensity, cycling and camera triggering. Testing of the system shows it can cycle 16 wavelengths at as fast as 1 ms per cycle. Additionally, more than 18% of the light transmits through the system. Our setup should allow for hyperspectral imaging of tissue and cells in real time.

  13. Design of signal reception and processing system of embedded ultrasonic endoscope

    Science.gov (United States)

    Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin

    2009-11-01

    Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.

  14. Automatic specular reflections removal for endoscopic images

    Science.gov (United States)

    Tan, Ke; Wang, Bin; Gao, Yuan

    2017-07-01

    Endoscopy imaging is utilized to provide a realistic view about the surfaces of organs inside the human body. Owing to the damp internal environment, these surfaces usually have a glossy appearance showing specular reflections. For many computer vision algorithms, the highlights created by specular reflections may become a significant source of error. In this paper, we present a novel method for restoration of the specular reflection regions from a single image. Specular restoration process starts with generating a substitute specular-free image with RPCA method. Then the specular removed image was obtained by taking the binary weighting template of highlight regions as the weighting for merging the original specular image and the substitute image. The modified template was furthermore discussed for the concealment of artificial effects in the edge of specular regions. Experimental results on the removal of the endoscopic image with specular reflections demonstrate the efficiency of the proposed method comparing to the existing methods.

  15. Three-dimensional photoacoustic endoscopic imaging of the rabbit esophagus.

    Science.gov (United States)

    Yang, Joon Mo; Favazza, Christopher; Yao, Junjie; Chen, Ruimin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2015-01-01

    We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which demonstrates the potential clinical utility of this endoscopic imaging modality. In the ex vivo imaging experiment, we acquired high-resolution motion-artifact-free three-dimensional photoacoustic images of the vasculatures distributed in the walls of the esophagi and extending to the neighboring mediastinal regions. Blood vessels with apparent diameters as small as 190 μm were resolved. Moreover, by taking advantage of the dual-mode high-resolution photoacoustic and ultrasound endoscopy, we could better identify and characterize the anatomic structures of the esophageal lumen, such as the mucosal and submucosal layers in the esophageal wall, and an esophageal branch of the thoracic aorta. In this paper, we present the first photoacoustic images showing the vasculature of a vertebrate esophagus and discuss the potential clinical applications and future development of photoacoustic endoscopy.

  16. Three-dimensional photoacoustic endoscopic imaging of the rabbit esophagus.

    Directory of Open Access Journals (Sweden)

    Joon Mo Yang

    Full Text Available We report photoacoustic and ultrasonic endoscopic images of two intact rabbit esophagi. To investigate the esophageal lumen structure and microvasculature, we performed in vivo and ex vivo imaging studies using a 3.8-mm diameter photoacoustic endoscope and correlated the images with histology. Several interesting anatomic structures were newly found in both the in vivo and ex vivo images, which demonstrates the potential clinical utility of this endoscopic imaging modality. In the ex vivo imaging experiment, we acquired high-resolution motion-artifact-free three-dimensional photoacoustic images of the vasculatures distributed in the walls of the esophagi and extending to the neighboring mediastinal regions. Blood vessels with apparent diameters as small as 190 μm were resolved. Moreover, by taking advantage of the dual-mode high-resolution photoacoustic and ultrasound endoscopy, we could better identify and characterize the anatomic structures of the esophageal lumen, such as the mucosal and submucosal layers in the esophageal wall, and an esophageal branch of the thoracic aorta. In this paper, we present the first photoacoustic images showing the vasculature of a vertebrate esophagus and discuss the potential clinical applications and future development of photoacoustic endoscopy.

  17. Biomedical Optical Imaging Technologies Design and Applications

    CERN Document Server

    2013-01-01

    This book provides an introduction to design of biomedical optical imaging technologies and their applications. The main topics include: fluorescence imaging, confocal imaging, micro-endoscope, polarization imaging, hyperspectral imaging, OCT imaging, multimodal imaging and spectroscopic systems. Each chapter is written by the world leaders of the respective fields, and will cover: principles and limitations of optical imaging technology, system design and practical implementation for one or two specific applications, including design guidelines, system configuration, optical design, component requirements and selection, system optimization and design examples, recent advances and applications in biomedical researches and clinical imaging. This book serves as a reference for students and researchers in optics and biomedical engineering.

  18. Application of image processing technology in yarn hairiness detection

    Directory of Open Access Journals (Sweden)

    Guohong ZHANG

    2016-02-01

    Full Text Available Digital image processing technology is one of the new methods for yarn detection, which can realize the digital characterization and objective evaluation of yarn appearance. This paper overviews the current status of development and application of digital image processing technology used for yarn hairiness evaluation, and analyzes and compares the traditional detection methods and this new developed method. Compared with the traditional methods, the image processing technology based method is more objective, fast and accurate, which is the vital development trend of the yarn appearance evaluation.

  19. Virtual endoscopic images by 3D FASE cisternography for neurovascular compression

    International Nuclear Information System (INIS)

    Ishimori, Takashi; Nakano, Satoru; Kagawa, Masahiro

    2003-01-01

    Three-dimensional fast asymmetric spin echo (3D FASE) cisternography provides high spatial resolution and excellent contrast as a water image acquisition technique. It is also useful for the evaluation of various anatomical regions. This study investigated the usefulness and limitations of virtual endoscopic images obtained by 3D FASE MR cisternography in the preoperative evaluation of patients with neurovascular compression. The study included 12 patients with neurovascular compression: 10 with hemifacial spasm and two with trigeminal neuralgia. The diagnosis was surgically confirmed in all patients. The virtual endoscopic images obtained were judged to be of acceptable quality for interpretation in all cases. The areas of compression identified in preoperative diagnosis with virtual endoscopic images showed good agreement with those observed from surgery, except in one case in which the common trunk of the anterior inferior cerebellar artery and posterior inferior cerebellar artery (AICA-PICA) bifurcated near the root exit zone of the facial nerve. The veins are displayed in some cases but not in others. The main advantage of generating virtual endoscopic images is that such images can be used for surgical simulation, allowing the neurosurgeon to perform surgical procedures with greater confidence. (author)

  20. The development of application technology for image processing in nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Bum; Kim, Woog Ki; Sohn, Surg Won; Kim, Seung Ho; Hwang, Suk Yeoung; Kim, Byung Soo

    1991-01-01

    The object of this project is to develop application technology of image processing in nuclear facilities where image signal are used for reliability and safety enhancement of operation, radiation exposure reduce of operator, and automation of operation processing. We has studied such application technology for image processing in nuclear facilities as non-tactile measurement, remote and automatic inspection, remote control, and enhanced analysis of visual information. On these bases, automation system and real-time image processing system are developed. Nuclear power consists in over 50% share of electic power supply of our country nowdays. So, it is required of technological support for top-notch technology in nuclear industry and its related fields. Especially, it is indispensable for image processing technology to enhance the reliabilty and safety of operation, to automate the process in a place like a nuclear power plant and radioactive envionment. It is important that image processing technology is linked to a nuclear engineering, and enhance the reliability abd safety of nuclear operation, as well as decrease the dose rate. (Author)

  1. Reevaluation of JPEG image compression to digitalized gastrointestinal endoscopic color images: a pilot study

    Science.gov (United States)

    Kim, Christopher Y.

    1999-05-01

    Endoscopic images p lay an important role in describing many gastrointestinal (GI) disorders. The field of radiology has been on the leading edge of creating, archiving and transmitting digital images. With the advent of digital videoendoscopy, endoscopists now have the ability to generate images for storage and transmission. X-rays can be compressed 30-40X without appreciable decline in quality. We reported results of a pilot study using JPEG compression of 24-bit color endoscopic images. For that study, the result indicated that adequate compression ratios vary according to the lesion and that images could be compressed to between 31- and 99-fold smaller than the original size without an appreciable decline in quality. The purpose of this study was to expand upon the methodology of the previous sty with an eye towards application for the WWW, a medium which would expand both clinical and educational purposes of color medical imags. The results indicate that endoscopists are able to tolerate very significant compression of endoscopic images without loss of clinical image quality. This finding suggests that even 1 MB color images can be compressed to well under 30KB, which is considered a maximal tolerable image size for downloading on the WWW.

  2. A Wireless Capsule Endoscope System With Low-Power Controlling and Processing ASIC.

    Science.gov (United States)

    Xinkai Chen; Xiaoyu Zhang; Linwei Zhang; Xiaowen Li; Nan Qi; Hanjun Jiang; Zhihua Wang

    2009-02-01

    This paper presents the design of a wireless capsule endoscope system. The proposed system is mainly composed of a CMOS image sensor, a RF transceiver and a low-power controlling and processing application specific integrated circuit (ASIC). Several design challenges involving system power reduction, system miniaturization and wireless wake-up method are resolved by employing optimized system architecture, integration of an area and power efficient image compression module, a power management unit (PMU) and a novel wireless wake-up subsystem with zero standby current in the ASIC design. The ASIC has been fabricated in 0.18-mum CMOS technology with a die area of 3.4 mm * 3.3 mm. The digital baseband can work under a power supply down to 0.95 V with a power dissipation of 1.3 mW. The prototype capsule based on the ASIC and a data recorder has been developed. Test result shows that proposed system architecture with local image compression lead to an average of 45% energy reduction for transmitting an image frame.

  3. Crowdsourcing for reference correspondence generation in endoscopic images.

    Science.gov (United States)

    Maier-Hein, Lena; Mersmann, Sven; Kondermann, Daniel; Stock, Christian; Kenngott, Hannes Gotz; Sanchez, Alexandro; Wagner, Martin; Preukschas, Anas; Wekerle, Anna-Laura; Helfert, Stefanie; Bodenstedt, Sebastian; Speidel, Stefanie

    2014-01-01

    Computer-assisted minimally-invasive surgery (MIS) is often based on algorithms that require establishing correspondences between endoscopic images. However, reference annotations frequently required to train or validate a method are extremely difficult to obtain because they are typically made by a medical expert with very limited resources, and publicly available data sets are still far too small to capture the wide range of anatomical/scene variance. Crowdsourcing is a new trend that is based on outsourcing cognitive tasks to many anonymous untrained individuals from an online community. To our knowledge, this paper is the first to investigate the concept of crowdsourcing in the context of endoscopic video image annotation for computer-assisted MIS. According to our study on publicly available in vivo data with manual reference annotations, anonymous non-experts obtain a median annotation error of 2 px (n = 10,000). By applying cluster analysis to multiple annotations per correspondence, this error can be reduced to about 1 px, which is comparable to that obtained by medical experts (n = 500). We conclude that crowdsourcing is a viable method for generating high quality reference correspondences in endoscopic video images.

  4. Imaging of Mucosal Inflammation: Current Technological Developments, Clinical Implications, and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Maximilian J. Waldner

    2017-10-01

    Full Text Available In recent years, various technological developments markedly improved imaging of mucosal inflammation in patients with inflammatory bowel diseases. Although technological developments such as high-definition-, chromo-, and autofluorescence-endoscopy led to a more precise and detailed assessment of mucosal inflammation during wide-field endoscopy, probe-based and stationary confocal laser microscopy enabled in vivo real-time microscopic imaging of mucosal surfaces within the gastrointestinal tract. Through the use of fluorochromes with specificity against a defined molecular target combined with endoscopic techniques that allow ultrastructural resolution, molecular imaging enables in vivo visualization of single molecules or receptors during endoscopy. Molecular imaging has therefore greatly expanded the clinical utility and applications of modern innovative endoscopy, which include the diagnosis, surveillance, and treatment of disease as well as the prediction of the therapeutic response of individual patients. Furthermore, non-invasive imaging techniques such as computed tomography, magnetic resonance imaging, scintigraphy, and ultrasound provide helpful information as supplement to invasive endoscopic procedures. In this review, we provide an overview on the current status of advanced imaging technologies for the clinical non-invasive and endoscopic evaluation of mucosal inflammation. Furthermore, the value of novel methods such as multiphoton microscopy, optoacoustics, and optical coherence tomography and their possible future implementation into clinical diagnosis and evaluation of mucosal inflammation will be discussed.

  5. Integrated endoscopic OCT system and in-vivo images of human internal organs

    Science.gov (United States)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Snopova, Ludmila; Shakhov, Andrei; Kuznetzova, Irina N.; Denisenko, Arkady; Pochinko, Vitaly; Chumakov, Yuri; Almasov, Valentin

    1998-04-01

    First results of endoscopic applications of optical coherence tomography (OCT) for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and endometrium as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  6. Laser scanning endoscope via an imaging fiber bundle for fluorescence imaging

    Science.gov (United States)

    Yeboah, Lorenz D.; Nestler, Dirk; Steiner, Rudolf W.

    1994-12-01

    Based on a laser scanning endoscope via an imaging fiber bundle, a new approach for a tumor diagnostic system has been developed to assist physicians in the diagnosis before the actual PDT is carried out. Laser induced, spatially resolved fluorescence images of diseased tissue can be compared with images received by video endoscopy using a white light source. The set- up is required to produce a better contrast between infected and healthy tissue and might serve as a constructive diagnostic help for surgeons. The fundamental idea is to scan a low-power laser beam on an imaging fiber bundle and to achieve a spatially resolved projection on the tissue surface. A sufficiently high laser intensity from the diode laser is concentrated on each single spot of the tissue exciting fluorescence when a dye has previously been accumulated. Subsequently, video image of the tissue is recorded and stored. With an image processing unit, video and fluorescence images are overlaid producing a picture of the fluorescence intensity in the environment of the observed tissue.

  7. ENDOSCOPIC TECHNOLOGIES IN EARLY RECTAL CANCER TREATMENT

    Directory of Open Access Journals (Sweden)

    D. V. Samsonov

    2015-01-01

    Full Text Available Total mesorectal excision is the “golden standard” of surgical treatment for rectal cancer. Development of endoscopic technologies allowed to implement the benefits of minimally invasive surgery in early rectal cancer treatment, decrease morbidity and mortality, improve functional outcome and quality of life. Oncological safety of this method is still a subject for discussion due to lack of lymph node harvest. Endoscopic operations for early rectal cancer are being actively implemented in daily practice, but lack of experience does not allow to include this method in national clinical prac-tice guidelines.

  8. Three-dimensional CT endoscopic images of the larynx. Clinical application of helical CT

    International Nuclear Information System (INIS)

    Yumoto, Eiji; Sanuki, Tetsuji; Yasuhara, Yoshifumi; Ochi, Takashi

    1998-01-01

    Twenty-seven patients with several laryngeal ailments underwent helical computed tomography (CT) on 37 occasions. Ten of these 27 patients suffered from unilateral vocal fold paralysis (UVFP). Three-dimensional (3D) images of the laryngeal lumen viewed from various angles were produced for all sets of CT volumetric data, except for three which contained excessive motion artifacts. The present paper examined whether 3D endoscopic images could offer useful diagnostic and therapeutic information about UVFP. The 3D endoscopic images viewed from the tracheal side and the hemilaryngeal images viewed from the opposite side could delineate the vocal folds, ventricular fold and ventricle three-dimensionally. Atrophy and hypotonic changes to the vocal fold and expansion of the ventricle on the affected side were clearly shown. The 3D endoscopic images accurately showed the phonosurgical effects on the laryngeal structures. The 3D endoscopic images could be produced even when the vocal folds could not be observed with conventional endoscopy due to their overadduction. Multiplanar reconstruction (MPR) images in the coronal plane were reconstructed at a right angle to the glottic axis when the whole larynx was deviated. In addition, coronal MPR images showed a better resolution among the different layers of the vocal fold soft tissue than X-ray tomography. In conclusion, 3D endoscopic images combined with coronal MPR images can provide useful diagnostic an therapeutic information about UVFP, although motion artifacts may occur. (author)

  9. Color reproduction and processing algorithm based on real-time mapping for endoscopic images.

    Science.gov (United States)

    Khan, Tareq H; Mohammed, Shahed K; Imtiaz, Mohammad S; Wahid, Khan A

    2016-01-01

    In this paper, we present a real-time preprocessing algorithm for image enhancement for endoscopic images. A novel dictionary based color mapping algorithm is used for reproducing the color information from a theme image. The theme image is selected from a nearby anatomical location. A database of color endoscopy image for different location is prepared for this purpose. The color map is dynamic as its contents change with the change of the theme image. This method is used on low contrast grayscale white light images and raw narrow band images to highlight the vascular and mucosa structures and to colorize the images. It can also be applied to enhance the tone of color images. The statistic visual representation and universal image quality measures show that the proposed method can highlight the mucosa structure compared to other methods. The color similarity has been verified using Delta E color difference, structure similarity index, mean structure similarity index and structure and hue similarity. The color enhancement was measured using color enhancement factor that shows considerable improvements. The proposed algorithm has low and linear time complexity, which results in higher execution speed than other related works.

  10. The feasibility of endoscopy-CT image registration in the head and neck without prospective endoscope tracking.

    Directory of Open Access Journals (Sweden)

    W Scott Ingram

    Full Text Available Endoscopic examinations are frequently-used procedures for patients with head and neck cancer undergoing radiotherapy, but radiation treatment plans are created on computed tomography (CT scans. Image registration between endoscopic video and CT could be used to improve treatment planning and analysis of radiation-related normal tissue toxicity. The purpose of this study was to explore the feasibility of endoscopy-CT image registration without prospective physical tracking of the endoscope during the examination.A novel registration technique called Location Search was developed. This technique uses physical constraints on the endoscope's view direction to search for the virtual endoscope coordinates that maximize the similarity between the endoscopic video frame and the virtual endoscopic image. Its performance was tested on phantom and patient images and compared to an established registration technique, Frame-To-Frame Tracking.In phantoms, Location Search had average registration errors of 0.55 ± 0.60 cm for point measurements and 0.29 ± 0.15 cm for object surface measurements. Frame-To-Frame Tracking achieved similar results on some frames, but it failed on others due to the virtual endoscope becoming lost. This weakness was more pronounced in patients, where Frame-To-Frame tracking could not make it through the nasal cavity. On successful patient video frames, Location Search was able to find endoscope positions with an average distance of 0.98 ± 0.53 cm away from the ground truth positions. However, it failed on many frames due to false similarity matches caused by anatomical structural differences between the endoscopic video and the virtual endoscopic images.Endoscopy-CT image registration without prospective physical tracking of the endoscope is possible, but more development is required to achieve an accuracy suitable for clinical translation.

  11. Improving superficial target delineation in radiation therapy with endoscopic tracking and registration

    Energy Technology Data Exchange (ETDEWEB)

    Weersink, R. A.; Qiu, J.; Hope, A. J.; Daly, M. J.; Cho, B. C. J.; DaCosta, R. S.; Sharpe, M. B.; Breen, S. L.; Chan, H.; Jaffray, D. A. [Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9, Canada and Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada) and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada) and Ontario Cancer Institute, University Health Network, Toronto, Ontario M5G 2M9 (Canada)

    2011-12-15

    Purpose: Target delineation within volumetric imaging is a critical step in the planning process of intensity modulated radiation therapy. In endoluminal cancers, endoscopy often reveals superficial areas of visible disease beyond what is seen on volumetric imaging. Quantitatively relating these findings to the volumetric imaging is prone to human error during the recall and contouring of the target. We have developed a method to improve target delineation in the radiation therapy planning process by quantitatively registering endoscopic findings contours traced on endoscopic images to volumetric imaging. Methods: Using electromagnetic sensors embedded in an endoscope, 2D endoscopic images were registered to computed tomography (CT) volumetric images by tracking the position and orientation of the endoscope relative to a CT image set. Regions-of-interest (ROI) in the 2D endoscopic view were delineated. A mesh created within the boundary of the ROI was projected onto the 3D image data, registering the ROI with the volumetric image. This 3D ROI was exported to clinical radiation treatment planning software. The precision and accuracy of the procedure was tested on two solid phantoms with superficial markings visible on both endoscopy and CT images. The first phantom was T-shaped tube with X-marks etched on the interior. The second phantom was an anatomically correct skull phantom with a phantom superficial lesion placed on the pharyngeal surface. Markings were contoured on the endoscope images and compared with contours delineated in the treatment planning system based on the CT images. Clinical feasibility was tested on three patients with early stage glottic cancer. Image-based rendering using manually identified landmarks was used to improve the registration. Results: Using the T-shaped phantom with X-markings, the 2D to 3D registration accuracy was 1.5-3.5 mm, depending on the endoscope position relative to the markings. Intraobserver standard variation was 0

  12. In vivo endoscopic OCT imaging of precancer and cancer states of human mucosa

    Science.gov (United States)

    Sergeev, Alexander M.; Gelikonov, V. M.; Gelikonov, G. V.; Feldchtein, Felix I.; Kuranov, R. V.; Gladkova, N. D.; Shakhova, N. M.; Snopova, L. B.; Shakhov, A. V.; Kuznetzova, I. A.; Denisenko, A. N.; Pochinko, V. V.; Chumakov, Yu P.; Streltzova, O. S.

    1997-12-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in respiratory, gastrointestinal, urinary and genital tracts are presented. A novel endoscopic OCT (EOCT) system has been created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, larynx, stomach, urinary bladder, uterine cervix and body as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancered tissue are distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  13. Classification of endoscopic capsule images by using color wavelet features, higher order statistics and radial basis functions.

    Science.gov (United States)

    Lima, C S; Barbosa, D; Ramos, J; Tavares, A; Monteiro, L; Carvalho, L

    2008-01-01

    This paper presents a system to support medical diagnosis and detection of abnormal lesions by processing capsule endoscopic images. Endoscopic images possess rich information expressed by texture. Texture information can be efficiently extracted from medium scales of the wavelet transform. The set of features proposed in this paper to code textural information is named color wavelet covariance (CWC). CWC coefficients are based on the covariances of second order textural measures, an optimum subset of them is proposed. Third and forth order moments are added to cope with distributions that tend to become non-Gaussian, especially in some pathological cases. The proposed approach is supported by a classifier based on radial basis functions procedure for the characterization of the image regions along the video frames. The whole methodology has been applied on real data containing 6 full endoscopic exams and reached 95% specificity and 93% sensitivity.

  14. Endoscopic OCT for in-vivo imaging of precancer and cancer states of human mucosa

    Science.gov (United States)

    Sergeev, Alexander M.; Gelikonov, Valentin M.; Gelikonov, Grigory V.; Feldchtein, Felix I.; Kuranov, Roman V.; Gladkova, Natalia D.; Shakhova, Natalia M.; Kuznetzova, Irina N.; Snopova, Ludmila; Denisenko, Arkady; Almasov, Valentin

    1998-01-01

    First results of endoscopic applications of optical coherence tomography for in vivo studies of human mucosa in gastrointestinal and genital tracts are presented. A novel endoscopic OCT system has ben created that is based on the integration of a sampling arm of an all-optical-fiber interferometer into standard endoscopic devices using their biopsy channel to transmit low-coherence radiation to investigated tissue. We have studied mucous membranes of esophagus, stomach and uterine cervix as typical localization for carcinomatous processes. Images of tumor tissues versus healthy tissues have been recorded and analyzed. Violations of well-defined stratified healthy mucosa structure in cancerous tissue is distinctly seen by EOCT, thus making this technique promising for early diagnosis of tumors and precise guiding of excisional biopsy.

  15. Emphysema. Imaging for endoscopic lung volume reduction

    International Nuclear Information System (INIS)

    Storbeck, B.; Oldigs, M.; Rabe, K.F.; Weber, C.; University Medical Center Hamburg-Eppendorf

    2015-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by two entities, the more airway-predominant type (''bronchitis'') on the one hand, and emphysema-predominant type on the other. Imaging via high-resolution computed tomography plays an important role in phenotyping COPD. For patients with advanced lung emphysema, new endoscopic lung volume reduction therapies (ELVR) have been developed. Proper selection of suitable patients requires thin-section reconstruction of volumetric CT image data sets also in coronal and sagittal orientation are required. In the current manuscript we will describe emphysema subtypes (centrilobular, paraseptal, panlobular), options for quantifying emphysema and this importance of regional distribution (homogeneous or heterogeneous, target area) as this is crucial for patient selection. Analysis of the interlobular fissures is obligatory despite the lack of standardization, as incomplete fissures indicate collateral ventilation (CV) via parenchymal bridges, which is an important criterion in choosing endoscopic methods of LVR. Every radiologist should be familiar with modern LVR therapies such as valves and coils, and furthermore should know what a lung doctor expects from radiologic evaluation (before and after ELVR). Finally we present a checklist as a quick reference for all steps concerning imaging for ELVR.

  16. Cecal intubation rates in different eras of endoscopic technological development.

    Science.gov (United States)

    Matyja, Maciej; Pasternak, Artur; Szura, Mirosław; Pędziwiatr, Michał; Major, Piotr; Rembiasz, Kazimierz

    2018-03-01

    Colonoscopy plays a critical role in colorectal cancer (CRC) screening and has been widely regarded as the gold standard. Cecal intubation rate (CIR) is one of the well-defined quality indicators used to assess colonoscopy. To assess the impact of new technologies on the quality of colonoscopy by assessing completion rates. This was a dual-center study at the 2 nd Department of Surgery at Jagiellonian University Medical College and at the Specialist Center "Medicina" in Krakow, Poland. The CIR and cecal intubation time (CIT) in three different eras of technological advancement were determined. The study enrolled 27 463 patients who underwent colonoscopy as part of a national CRC screening program. The patients were divided into three groups: group I - 3408 patients examined between 2000 and 2003 (optical endoscopes); group II - 10 405 patients examined between 2004 and 2008 (standard electronic endoscopes); and group III - 13 650 patients examined between 2009 and 2014 (modern endoscopes). There were statistically significant differences in the CIR between successive eras. The CIR in group I (2000-2003) was 69.75%, in group II (2004-2008) was 92.32%, and in group III (2009-2014) was 95.17%. The mean CIT was significantly reduced in group III. Our study shows that the technological innovation of novel endoscopy devices has a great influence on the effectiveness of the CRC screening program. The new era of endoscopic technological development has the potential to reduce examination-related patient discomfort, obviate the need for sedation and increase diagnostic yields.

  17. [Study of Image Quality Comparison Based on the MTF Method Between Different Medical Rigid Endoscopes in an In Vitro Model].

    Science.gov (United States)

    Wang, Yunlong; Ji, Jun; Jiang, Changsong; Huang, Zengyue

    2015-04-01

    This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.

  18. Image-based navigation for a robotized flexible endoscope

    NARCIS (Netherlands)

    van der Stap, N.; Slump, Cornelis H.; Broeders, Ivo Adriaan Maria Johannes; van der Heijden, Ferdinand; Luo, Xiongbiao; Reichl, Tobias; Mirota, Daniel; Soper, Timothy

    2014-01-01

    Robotizing flexible endoscopy enables image-based control of endoscopes. Especially during high-throughput procedures, such as a colonoscopy, navigation support algorithms could improve procedure turnaround and ergonomics for the endoscopist. In this study, we have developed and implemented a

  19. Imaging of common bile duct by linear endoscopic ultrasound

    Institute of Scientific and Technical Information of China (English)

    Malay; Sharma; Amit; Pathak; Abid; Shoukat; Chittapuram; Srinivasan; Rameshbabu; Akash; Ajmera; Zeeshn; Ahamad; Wani; Praveer; Rai

    2015-01-01

    Imaging of common bile duct(CBD) can be done by many techniques. Endoscopic retrograde cholangiopancreaticography is considered the gold standard for imaging of CBD. A standard technique of imaging of CBD by endoscopic ultrasound(EUS) has not been specifically described. The available descriptions mention different stations of imaging from the stomach and duodenum. The CBD lies closest to duodenum and choice of imaging may be restricted to duodenum for many operators. Generally most operators prefer multi station imaging during EUS and the choice of selecting the initial station varies from operator to operator. Detailed evaluation of CBD is frequently the main focus of imaging during EUS and in such situations multi station imaging with a high-resolution ultrasound scanner may provide useful information. Examination of the CBD is one of the primary indications for doing an EUS and it can be done from five stations:(1) the fundus of stomach;(2) body of stomach;(3) duodenal bulb;(4) descending duodenum; and(5) antrum. Following down the upper 1/3rd of CBD can do imaging of entire CBD from the liver window and following up the lower 1/3rd of CBD can do imaging of entire CBD from the pancreatic window. This article aims at simplifying the techniques of imaging of CBD by linear EUS.

  20. Application of artificial intelligence using a convolutional neural network for detecting gastric cancer in endoscopic images.

    Science.gov (United States)

    Hirasawa, Toshiaki; Aoyama, Kazuharu; Tanimoto, Tetsuya; Ishihara, Soichiro; Shichijo, Satoki; Ozawa, Tsuyoshi; Ohnishi, Tatsuya; Fujishiro, Mitsuhiro; Matsuo, Keigo; Fujisaki, Junko; Tada, Tomohiro

    2018-07-01

    Image recognition using artificial intelligence with deep learning through convolutional neural networks (CNNs) has dramatically improved and been increasingly applied to medical fields for diagnostic imaging. We developed a CNN that can automatically detect gastric cancer in endoscopic images. A CNN-based diagnostic system was constructed based on Single Shot MultiBox Detector architecture and trained using 13,584 endoscopic images of gastric cancer. To evaluate the diagnostic accuracy, an independent test set of 2296 stomach images collected from 69 consecutive patients with 77 gastric cancer lesions was applied to the constructed CNN. The CNN required 47 s to analyze 2296 test images. The CNN correctly diagnosed 71 of 77 gastric cancer lesions with an overall sensitivity of 92.2%, and 161 non-cancerous lesions were detected as gastric cancer, resulting in a positive predictive value of 30.6%. Seventy of the 71 lesions (98.6%) with a diameter of 6 mm or more as well as all invasive cancers were correctly detected. All missed lesions were superficially depressed and differentiated-type intramucosal cancers that were difficult to distinguish from gastritis even for experienced endoscopists. Nearly half of the false-positive lesions were gastritis with changes in color tone or an irregular mucosal surface. The constructed CNN system for detecting gastric cancer could process numerous stored endoscopic images in a very short time with a clinically relevant diagnostic ability. It may be well applicable to daily clinical practice to reduce the burden of endoscopists.

  1. Endoscopic device for functional imaging of the retina

    Science.gov (United States)

    Barriga, Simon; Lohani, Sweyta; Martell, Bret; Soliz, Peter; Ts'o, Dan

    2011-03-01

    Non-invasive imaging of retinal function based on the recording of spatially distributed reflectance changes evoked by visual stimuli has to-date been performed primarily using modified commercial fundus cameras. We have constructed a prototype retinal functional imager, using a commercial endoscope (Storz) for the frontend optics, and a low-cost back-end that includes the needed dichroic beam splitter to separate the stimulus path from the imaging path. This device has been tested to demonstrate its performance for the delivery of adequate near infrared (NIR) illumination, intensity of the visual stimulus and reflectance return in the imaging path. The current device was found to be capable of imaging reflectance changes of 0.1%, similar to that observable using the modified commercial fundus camera approach. The visual stimulus (a 505nm spot of 0.5secs) was used with an interrogation illumination of 780nm, and a sequence of imaged captured. At each pixel, the imaged signal was subtracted and normalized by the baseline reflectance, so that the measurement was ΔR/R. The typical retinal activity signal observed had a ΔR/R of 0.3-1.0%. The noise levels were measured when no stimulus was applied and found to vary between +/- 0.05%. Functional imaging has been suggested as a means to provide objective information on retina function that may be a preclinical indicator of ocular diseases, such as age-related macular degeneration (AMD), glaucoma, and diabetic retinopathy. The endoscopic approach promises to yield a significantly more economical retinal functional imaging device that would be clinically important.

  2. Segmentation of Clinical Endoscopic Images Based on the Classification of Topological Vector Features

    Directory of Open Access Journals (Sweden)

    O. A. Dunaeva

    2013-01-01

    Full Text Available In this work, we describe a prototype of an automatic segmentation system and annotation of endoscopy images. The used algorithm is based on the classification of vectors of the topological features of the original image. We use the image processing scheme which includes image preprocessing, calculation of vector descriptors defined for every point of the source image and the subsequent classification of descriptors. Image preprocessing includes finding and selecting artifacts and equalizating the image brightness. In this work, we give the detailed algorithm of the construction of topological descriptors and the classifier creating procedure based on mutual sharing the AdaBoost scheme and a naive Bayes classifier. In the final section, we show the results of the classification of real endoscopic images.

  3. Novel computer-based endoscopic camera

    Science.gov (United States)

    Rabinovitz, R.; Hai, N.; Abraham, Martin D.; Adler, Doron; Nissani, M.; Fridental, Ron; Vitsnudel, Ilia

    1995-05-01

    We have introduced a computer-based endoscopic camera which includes (a) unique real-time digital image processing to optimize image visualization by reducing over exposed glared areas and brightening dark areas, and by accentuating sharpness and fine structures, and (b) patient data documentation and management. The image processing is based on i Sight's iSP1000TM digital video processor chip and Adaptive SensitivityTM patented scheme for capturing and displaying images with wide dynamic range of light, taking into account local neighborhood image conditions and global image statistics. It provides the medical user with the ability to view images under difficult lighting conditions, without losing details `in the dark' or in completely saturated areas. The patient data documentation and management allows storage of images (approximately 1 MB per image for a full 24 bit color image) to any storage device installed into the camera, or to an external host media via network. The patient data which is included with every image described essential information on the patient and procedure. The operator can assign custom data descriptors, and can search for the stored image/data by typing any image descriptor. The camera optics has extended zoom range of f equals 20 - 45 mm allowing control of the diameter of the field which is displayed on the monitor such that the complete field of view of the endoscope can be displayed on all the area of the screen. All these features provide versatile endoscopic camera with excellent image quality and documentation capabilities.

  4. Assessment of colonoscopy by use of magnetic endoscopic imaging

    DEFF Research Database (Denmark)

    Nerup, Nikolaj; Preisler, Louise; Svendsen, Morten Bo Søndergaard

    2015-01-01

    and a difficult case. SETTING: Center for Clinical Education, Capital Region of Denmark. MAIN OUTCOME MEASUREMENTS: By using magnetic endoscopic imaging, we developed a colonoscopy progression score (CoPS). A pass/fail score was established by using the contrast-group method. RESULTS: We found significant...... differences in performance between the 2 groups using the CoPS in both case scenarios (easy: P heterogeneity of the experienced group resulted in a high passing score for the difficult case, which led to the failing of the less experienced...... in the group. The CoPS does not consider polyp detection rate, tissue damage, or patient discomfort. CONCLUSIONS: We developed a score of progression in colonoscopy, based on magnetic endoscopic imaging. With the same tool, a map of progression in colonoscopy can be provided. The CoPS and map of progression...

  5. Endoscopic optical coherence tomography for imaging the tympanic membrane

    Science.gov (United States)

    Burkhardt, Anke; Walther, Julia; Cimalla, Peter; Bornitz, Matthias; Koch, Edmund

    2011-06-01

    Optical coherence tomography (OCT) is an imaging modality that enables micrometer-scale contactless subsurface imaging of biological tissue. Endoscopy, as another imaging method, has the potential of imaging tubular organs and cavities and therefore has opened up several application areas not accessible before. The combination of OCT and endoscopy uses the advantages of both methods and consequently allows additional imaging of structures beneath surfaces inside cavities. Currently, visual investigations on the surface of the human tympanic membrane are possible but only with expert eyes. up to now, visual imaging of the outer ear up to the tympanic membrane can be carried out by an otoscope, an operating microscope or an endoscope. In contrast to these devices, endoscopy has the advantage of imaging the whole tympanic membrane with one view. The intention of this research is the development of an endoscopic optical coherence tomography (EOCT) device for imaging the tympanic membrane depth-resolved and structures behind it. Detection of fluids in the middle ear, which function as an indicator for otitis media, could help to avoid the application of antibiotics. It is possible to detect a congeries of fluids with the otoscope but the ambition is to the early detection by OCT. The developed scanner head allows imaging in working distances in the range from zero up to 5 mm with a field of view of 2 mm. In the next step, the scanner head should be improved to increase the working distance and the field of view.

  6. Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

    Science.gov (United States)

    Tsai, Tsung-Han; Potsaid, Benjamin; Tao, Yuankai K; Jayaraman, Vijaysekhar; Jiang, James; Heim, Peter J S; Kraus, Martin F; Zhou, Chao; Hornegger, Joachim; Mashimo, Hiroshi; Cable, Alex E; Fujimoto, James G

    2013-07-01

    We developed a micromotor based miniature catheter with an outer diameter of 3.2 mm for ultrahigh speed endoscopic swept source optical coherence tomography (OCT) using a vertical cavity surface-emitting laser (VCSEL) at a 1 MHz axial scan rate. The micromotor can rotate a micro-prism at several hundred frames per second with less than 5 V drive voltage to provide fast and stable scanning, which is not sensitive to the bending of the catheter. The side-viewing probe can be pulled back to acquire a three-dimensional (3D) data set covering a large area on the specimen. The VCSEL provides a high axial scan rate to support dense sampling under high frame rate operation. Using a high speed data acquisition system, in vivo 3D-OCT imaging in the rabbit GI tract and ex vivo imaging of a human colon specimen with 8 μm axial resolution, 8 μm lateral resolution and 1.2 mm depth range in tissue at a frame rate of 400 fps was demonstrated.

  7. Endoscopic inspection of steam turbines

    International Nuclear Information System (INIS)

    Maliniemi, H.; Muukka, E.

    1990-01-01

    For over ten years, Imatran Voima Oy (IVO) has developed, complementary inspection methods for steam turbine condition monitoring, which can be applied both during operation and shutdown. One important method used periodically during outages is endoscopic inspection. The inspection is based on the method where the internal parts of the turbine is inspected through access borings with endoscope and where the magnified figures of the internal parts is seen on video screen. To improve inspection assurance, an image-processing based pattern recognition method for cracks has been developed for the endoscopic inspection of turbine blades. It is based on the deduction conditions derived from the crack shape. The computer gives an alarm of a crack detection and prints a simulated image of the crack, which is then checked manually

  8. A deep learning approach for detecting and correcting highlights in endoscopic images

    NARCIS (Netherlands)

    Rodriguez-Sanchez, Antonio; Chea, Daly; Azzopardi, George; Stabinger, Sebastian

    2017-01-01

    The image of an object changes dramatically depending on the lightning conditions surrounding that object. Shadows, reflections and highlights can make the object very difficult to be recognized for an automatic system. Additionally, images used in medical applications, such as endoscopic images and

  9. Development of X-ray radiography examination technology by image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Min, Duck Kee; Koo, Dae Seo; Kim, Eun Ka [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-06-01

    Because the dimension of nuclear fuel rods was measured with rapidity and accuracy by X-ray radiography examination, the set-up of image processing system which was composed of 979 CCD-L camera, image processing card and fluorescent lighting was carried out, and the image processing system enabled image processing to perform. The examination technology of X-ray radiography, which enabled dimension measurement of nuclear fuel rods to perform, was developed by image processing method. The result of dimension measurement of standard fuel rod by image processing method was 2% reduction in relative measuring error than that of X-ray radiography film, while the former was better by 100 {approx} 200 {mu}m in measuring accuracy than the latter. (author). 9 refs., 22 figs., 3 tabs.

  10. Low-complexity video encoding method for wireless image transmission in capsule endoscope.

    Science.gov (United States)

    Takizawa, Kenichi; Hamaguchi, Kiyoshi

    2010-01-01

    This paper presents a low-complexity video encoding method applicable for wireless image transmission in capsule endoscopes. This encoding method is based on Wyner-Ziv theory, in which side information available at a transmitter is treated as side information at its receiver. Therefore complex processes in video encoding, such as estimation of the motion vector, are moved to the receiver side, which has a larger-capacity battery. As a result, the encoding process is only to decimate coded original data through channel coding. We provide a performance evaluation for a low-density parity check (LDPC) coding method in the AWGN channel.

  11. Automated processing of endoscopic surgical instruments.

    Science.gov (United States)

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  12. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    International Nuclear Information System (INIS)

    Ingram, W; Rao, A; Wendt, R; Court, L; Yang, J; Beadle, B

    2015-01-01

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration

  13. WE-AB-BRA-12: Virtual Endoscope Tracking for Endoscopy-CT Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Ingram, W; Rao, A; Wendt, R; Court, L [The University of Texas MD Anderson Cancer Center, Houston, TX (United States); The University of Texas Graduate School of Biomedical Sciences, Houston, TX (United States); Yang, J; Beadle, B [The University of Texas MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: The use of endoscopy in radiotherapy will remain limited until we can register endoscopic video to CT using standard clinical equipment. In this phantom study we tested a registration method using virtual endoscopy to measure CT-space positions from endoscopic video. Methods: Our phantom is a contorted clay cylinder with 2-mm-diameter markers in the luminal surface. These markers are visible on both CT and endoscopic video. Virtual endoscope images were rendered from a polygonal mesh created by segmenting the phantom’s luminal surface on CT. We tested registration accuracy by tracking the endoscope’s 6-degree-of-freedom coordinates frame-to-frame in a video recorded as it moved through the phantom, and using these coordinates to measure CT-space positions of markers visible in the final frame. To track the endoscope we used the Nelder-Mead method to search for coordinates that render the virtual frame most similar to the next recorded frame. We measured the endoscope’s initial-frame coordinates using a set of visible markers, and for image similarity we used a combination of mutual information and gradient alignment. CT-space marker positions were measured by projecting their final-frame pixel addresses through the virtual endoscope to intersect with the mesh. Registration error was quantified as the distance between this intersection and the marker’s manually-selected CT-space position. Results: Tracking succeeded for 6 of 8 videos, for which the mean registration error was 4.8±3.5mm (24 measurements total). The mean error in the axial direction (3.1±3.3mm) was larger than in the sagittal or coronal directions (2.0±2.3mm, 1.7±1.6mm). In the other 2 videos, the virtual endoscope got stuck in a false minimum. Conclusion: Our method can successfully track the position and orientation of an endoscope, and it provides accurate spatial mapping from endoscopic video to CT. This method will serve as a foundation for an endoscopy-CT registration

  14. The key network communication technology in large radiation image cooperative process system

    International Nuclear Information System (INIS)

    Li Zheng; Kang Kejun; Gao Wenhuan; Wang Jingjin

    1998-01-01

    Large container inspection system (LCIS) based on radiation imaging technology is a powerful tool for the customs to check the contents inside a large container without opening it. An image distributed network system is composed of operation manager station, image acquisition station, environment control station, inspection processing station, check-in station, check-out station, database station by using advanced network technology. Mass data, such as container image data, container general information, manifest scanning data, commands and status, must be on-line transferred between different stations. Advanced network communication technology is presented

  15. Ling classification describes endoscopic progressive process of achalasia and successful peroral endoscopy myotomy prevents endoscopic progression of achalasia.

    Science.gov (United States)

    Zhang, Wen-Gang; Linghu, En-Qiang; Chai, Ning-Li; Li, Hui-Kai

    2017-05-14

    To verify the hypothesis that the Ling classification describes the endoscopic progressive process of achalasia and determine the ability of successful peroral endoscopic myotomy (POEM) to prevent endoscopic progression of achalasia. We retrospectively reviewed the endoscopic findings, symptom duration, and manometric data in patients with achalasia. A total of 359 patients (197 women, 162 men) with a mean age of 42.1 years (range, 12-75 years) were evaluated. Symptom duration ranged from 2 to 360 mo, with a median of 36 mo. Patients were classified with Ling type I ( n = 119), IIa ( n = 106), IIb ( n = 60), IIc ( n = 60), or III ( n = 14), according to the Ling classification. Of the 359 patients, 349 underwent POEM, among whom 21 had an endoscopic follow-up for more than 2 years. Pre-treatment and post-treatment Ling classifications of these 21 patients were compared. Symptom duration increased significantly with increasing Ling classification (from I to III) ( P achalasia and may be able to serve as an endoscopic assessment criterion for achalasia. Successful POEM (Eckardt score ≤ 3) seems to have the ability to prevent endoscopic evolvement of achalasia. However, studies with larger populations are warranted to confirm our findings.

  16. Use of hyperspectral imaging technology to develop a diagnostic support system for gastric cancer

    Science.gov (United States)

    Goto, Atsushi; Nishikawa, Jun; Kiyotoki, Shu; Nakamura, Munetaka; Nishimura, Junichi; Okamoto, Takeshi; Ogihara, Hiroyuki; Fujita, Yusuke; Hamamoto, Yoshihiko; Sakaida, Isao

    2015-01-01

    Hyperspectral imaging (HSI) is a new technology that obtains spectroscopic information and renders it in image form. This study examined the difference in the spectral reflectance (SR) of gastric tumors and normal mucosa recorded with a hyperspectral camera equipped with HSI technology and attempted to determine the specific wavelength that is useful for the diagnosis of gastric cancer. A total of 104 gastric tumors removed by endoscopic submucosal dissection from 96 patients at Yamaguchi University Hospital were recorded using a hyperspectral camera. We determined the optimal wavelength and the cut-off value for differentiating tumors from normal mucosa to establish a diagnostic algorithm. We also attempted to highlight tumors by image processing using the hyperspectral camera's analysis software. A wavelength of 770 nm and a cut-off value of 1/4 the corrected SR were selected as the respective optimal wavelength and cut-off values. The rates of sensitivity, specificity, and accuracy of the algorithm's diagnostic capability were 71%, 98%, and 85%, respectively. It was possible to enhance tumors by image processing at the 770-nm wavelength. HSI can be used to measure the SR in gastric tumors and to differentiate between tumorous and normal mucosa.

  17. Endoscopic Therapeutic Approach for Dysplasia in Inflammatory Bowel Disease

    Directory of Open Access Journals (Sweden)

    Sung Noh Hong

    2017-09-01

    Full Text Available Long-standing intestinal inflammation in patients with inflammatory bowel disease (IBD induces dysplastic change in the intestinal mucosa and increases the risk of subsequent colorectal cancer. The evolving endoscopic techniques and technologies, including dye spraying methods and high-definition images, have been replacing random biopsies and have been revealed as more practical and efficient for detection of dysplasia in IBD patients. In addition, they have potential usefulness in detailed characterization of lesions and in the assessment of endoscopic resectability. Most dysplastic lesions without an unclear margin, definite ulceration, non-lifting sign, and high index of malignant change with suspicion for lymph node or distant metastases can be removed endoscopically. However, endoscopic resection of dysplasia in chronic IBD patients is usually difficult because it is often complicated by submucosal fibrosis. In patients with dysplasias that demonstrate submucosa fibrosis or a large size (≥20 mm, endoscopic submucosal dissection (ESD or ESD with snaring (simplified or hybrid ESD is an alternative option and may avoid a colectomy. However, a standardized endoscopic therapeutic approach for dysplasia in IBD has not been established yet, and dedicated specialized endoscopists with interest in IBD are needed to fully investigate recent emerging techniques and technologies.

  18. Flow mapping of multiphase flows using a novel single stem endoscopic particle image velocimetry instrument

    International Nuclear Information System (INIS)

    Lad, N; Adebayo, D; Aroussi, A

    2011-01-01

    Particle image velocimetry (PIV) is a successful flow mapping technique which can optically quantify large portions of a flow regime. This enables the method to be completely non-intrusive. The ability to be non-intrusive to any flow has allowed PIV to be used in a large range of industrial sectors for many applications. However, a fundamental disadvantage of the conventional PIV technique is that it cannot easily be used with flows which have no or limited optical access. Flows which have limited optical access for PIV measurement have been addressed using endoscopic PIV techniques. This system uses two separate probes which relay a light sheet and imaging optics to a planar position within the desired flow regime. This system is effective in medical and engineering applications. The present study has been involved in the development of a new endoscopic PIV system which integrates the illumination and imaging optics into one rigid probe. This paper focuses on the validation of the images taken from the novel single stem endoscopic PIV system. The probe is used within atomized spray flow and is compared with conventional PIV measurement and also pitot-static data. The endoscopic PIV system provides images which create localized velocity maps that are comparable with the global measurement of the conventional PIV system. The velocity information for both systems clearly show similar results for the spray characterization and are also validated using the pitot-static data

  19. Simple fibre based dispersion management for two-photon excited fluorescence imaging through an endoscope

    DEFF Research Database (Denmark)

    Dimopoulos, Konstantinos; Marti, Dominik; Andersen, Peter E.

    2018-01-01

    We want to implement two-photon excitation fluorescence microscopy (TPEFM) into endoscopes, since TPEFM can provide relevant biomarkers for cancer staging and grading in hollow organs, endoscopically accessible through natural orifices. However, many obstacles must be overcome, among others...... the delivery of short laser pulses to the distal end of the endoscope. To this avail, we present imaging results using an all-fibre dispersion management scheme in a TPEFM setup. The scheme has been conceived by Jespersen et al. in 20101 and relies on the combination of a single mode fibre with normal...

  20. Clinical Evaluation of Endoscopic Trimodal Imaging for the Detection and Differentiation of Colonic Polyps

    NARCIS (Netherlands)

    van den Broek, Frank J. C.; Fockens, Paul; van Eeden, Susanne; Kara, Mohammed A.; Hardwick, James C. H.; Reitsma, Johannes B.; Dekker, Evelien

    2009-01-01

    Background & Aims: Endoscopic trimodal imaging (ETMI) incorporates high-resolution endoscopy (HRE) and autofluorescence imaging (AFI) for adenoma detection, and narrow-band imaging (NBI) for differentiation of adenomas from nonneoplastic polyps. The aim of this study was to compare AFI with HRE for

  1. Pancreas imaging by computed tomography after endoscopic retrograde pancreatography

    International Nuclear Information System (INIS)

    Frick, M.P.; O'Leary, J.F.; Salomonowitz, E.; Stoltenberg, E.; Hutton, S.; Gedgaudas, E.

    1984-01-01

    A method using CT after endoscopic retrograde pancreatography (CT-ERP) is described for pancreatic imaging. When using an ERP technique in the canine model comparable to that used in humans, small amounts of contrast material in peripheral pancreatic radicles resulted in enhancement of the pancreas on CT scans. Nine patients were also studied by CT-ERP images. The main pancreatic duct was seen on delayed images. In cases of chronic pancreatitis (n = 2), pancreatic opacification was patchy and heterogeneous. There was no contrast-material enhancement in areas of pancreatic carcimomas (n = 2). CT-ERP showed the true extent of carcinoma better than ERP alone

  2. A standardized imaging protocol for the endoscopic prediction of dysplasia within sessile serrated polyps (with video).

    Science.gov (United States)

    Tate, David J; Jayanna, Mahesh; Awadie, Halim; Desomer, Lobke; Lee, Ralph; Heitman, Steven J; Sidhu, Mayenaaz; Goodrick, Kathleen; Burgess, Nicholas G; Mahajan, Hema; McLeod, Duncan; Bourke, Michael J

    2018-01-01

    Dysplasia within sessile serrated polyps (SSPs) is difficult to detect and may be mistaken for an adenoma, risking incomplete resection of the background serrated tissue, and is strongly implicated in interval cancer after colonoscopy. The use of endoscopic imaging to detect dysplasia within SSPs has not been systematically studied. Consecutively detected SSPs ≥8 mm in size were evaluated by using a standardized imaging protocol at a tertiary-care endoscopy center over 3 years. Lesions suspected as SSPs were analyzed with high-definition white light then narrow-band imaging. A demarcated area with a neoplastic pit pattern (Kudo type III/IV, NICE type II) was sought among the serrated tissue. If this was detected, the lesion was labeled dysplastic (sessile serrated polyp with dysplasia); if not, it was labeled non-dysplastic (sessile serrated polyp without dysplasia). Histopathology was reviewed by 2 blinded specialist GI pathologists. A total of 141 SSPs were assessed in 83 patients. Median lesion size was 15.0 mm (interquartile range 10-20), and 54.6% were in the right side of the colon. Endoscopic evidence of dysplasia was detected in 36 of 141 (25.5%) SSPs; of these, 5 of 36 (13.9%) lacked dysplasia at histopathology. Two of 105 (1.9%) endoscopically designated non-dysplastic SSPs had dysplasia at histopathology. Endoscopic imaging, therefore, had an accuracy of 95.0% (95% confidence interval [CI], 90.1%-97.6%) and a negative predictive value of 98.1% (95% CI, 92.6%-99.7%) for detection of dysplasia within SSPs. Dysplasia within SSPs can be detected accurately by using a simple, broadly applicable endoscopic imaging protocol that allows complete resection. Independent validation of this protocol and its dissemination to the wider endoscopic community may have a significant impact on rates of interval cancer. (Clinical trial registration number: NCT03100552.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All

  3. TECHNOLOGIES OF BRAIN IMAGES PROCESSING

    Directory of Open Access Journals (Sweden)

    O.M. Klyuchko

    2017-12-01

    Full Text Available The purpose of present research was to analyze modern methods of processing biological images implemented before storage in databases for biotechnological purposes. The databases further were incorporated into web-based digital systems. Examples of such information systems were described in the work for two levels of biological material organization; databases for storing data of histological analysis and of whole brain were described. Methods of neuroimaging processing for electronic brain atlas were considered. It was shown that certain pathological features can be revealed in histological image processing. Several medical diagnostic techniques (for certain brain pathologies, etc. as well as a few biotechnological methods are based on such effects. Algorithms of image processing were suggested. Electronic brain atlas was conveniently for professionals in different fields described in details. Approaches of brain atlas elaboration, “composite” scheme for large deformations as well as several methods of mathematic images processing were described as well.

  4. Eyewear-style three-dimensional endoscope derived from microstructured polymer fiber with the function of image transmission

    International Nuclear Information System (INIS)

    Kong De-Peng; Wang Li-Li; He Zheng-Quan; Ma Tian; Chu Jiu-Rong

    2013-01-01

    A method of fabricating multi-core polymer image fiber is proposed. Image fiber preform is fabricated by stacking thousands of polymer fibers each with a 0.25-mm diameter orderly in a die by only one step. The preform is heated and stretched into image fiber with an outer diameter of 2 mm. Then a portable eyewear-style three-dimensional (3D) endoscope system is designed, fabricated, and characterized. This endoscopic system is composed of two graded index lenses, two pieces of 0.35-m length image guide fibers, and a pair of oculars. It shows good flexibility and portability, and can provide the depth information accordingly. (general)

  5. Optimizing Endoscope Reprocessing Resources Via Process Flow Queuing Analysis.

    Science.gov (United States)

    Seelen, Mark T; Friend, Tynan H; Levine, Wilton C

    2018-05-04

    The Massachusetts General Hospital (MGH) is merging its older endoscope processing facilities into a single new facility that will enable high-level disinfection of endoscopes for both the ORs and Endoscopy Suite, leveraging economies of scale for improved patient care and optimal use of resources. Finalized resource planning was necessary for the merging of facilities to optimize staffing and make final equipment selections to support the nearly 33,000 annual endoscopy cases. To accomplish this, we employed operations management methodologies, analyzing the physical process flow of scopes throughout the existing Endoscopy Suite and ORs and mapping the future state capacity of the new reprocessing facility. Further, our analysis required the incorporation of historical case and reprocessing volumes in a multi-server queuing model to identify any potential wait times as a result of the new reprocessing cycle. We also performed sensitivity analysis to understand the impact of future case volume growth. We found that our future-state reprocessing facility, given planned capital expenditures for automated endoscope reprocessors (AERs) and pre-processing sinks, could easily accommodate current scope volume well within the necessary pre-cleaning-to-sink reprocessing time limit recommended by manufacturers. Further, in its current planned state, our model suggested that the future endoscope reprocessing suite at MGH could support an increase in volume of at least 90% over the next several years. Our work suggests that with simple mathematical analysis of historic case data, significant changes to a complex perioperative environment can be made with ease while keeping patient safety as the top priority.

  6. Automated endoscopic navigation and advisory system from medical image

    Science.gov (United States)

    Kwoh, Chee K.; Khan, Gul N.; Gillies, Duncan F.

    1999-05-01

    In this paper, we present a review of the research conducted by our group to design an automatic endoscope navigation and advisory system. The whole system can be viewed as a two-layer system. The first layer is at the signal level, which consists of the processing that will be performed on a series of images to extract all the identifiable features. The information is purely dependent on what can be extracted from the 'raw' images. At the signal level, the first task is performed by detecting a single dominant feature, lumen. Few methods of identifying the lumen are proposed. The first method used contour extraction. Contours are extracted by edge detection, thresholding and linking. This method required images to be divided into overlapping squares (8 by 8 or 4 by 4) where line segments are extracted by using a Hough transform. Perceptual criteria such as proximity, connectivity, similarity in orientation, contrast and edge pixel intensity, are used to group edges both strong and weak. This approach is called perceptual grouping. The second method is based on a region extraction using split and merge approach using spatial domain data. An n-level (for a 2' by 2' image) quadtree based pyramid structure is constructed to find the most homogenous large dark region, which in most cases corresponds to the lumen. The algorithm constructs the quadtree from the bottom (pixel) level upward, recursively and computes the mean and variance of image regions corresponding to quadtree nodes. On reaching the root, the largest uniform seed region, whose mean corresponds to a lumen is selected that is grown by merging with its neighboring regions. In addition to the use of two- dimensional information in the form of regions and contours, three-dimensional shape can provide additional information that will enhance the system capabilities. Shape or depth information from an image is estimated by various methods. A particular technique suitable for endoscopy is the shape from shading

  7. SU-C-18A-02: Image-Based Camera Tracking: Towards Registration of Endoscopic Video to CT

    International Nuclear Information System (INIS)

    Ingram, S; Rao, A; Wendt, R; Castillo, R; Court, L; Yang, J; Beadle, B

    2014-01-01

    Purpose: Endoscopic examinations are routinely performed on head and neck and esophageal cancer patients. However, these images are underutilized for radiation therapy because there is currently no way to register them to a CT of the patient. The purpose of this work is to develop a method to track the motion of an endoscope within a structure using images from standard clinical equipment. This method will be incorporated into a broader endoscopy/CT registration framework. Methods: We developed a software algorithm to track the motion of an endoscope within an arbitrary structure. We computed frame-to-frame rotation and translation of the camera by tracking surface points across the video sequence and utilizing two-camera epipolar geometry. The resulting 3D camera path was used to recover the surrounding structure via triangulation methods. We tested this algorithm on a rigid cylindrical phantom with a pattern spray-painted on the inside. We did not constrain the motion of the endoscope while recording, and we did not constrain our measurements using the known structure of the phantom. Results: Our software algorithm can successfully track the general motion of the endoscope as it moves through the phantom. However, our preliminary data do not show a high degree of accuracy in the triangulation of 3D point locations. More rigorous data will be presented at the annual meeting. Conclusion: Image-based camera tracking is a promising method for endoscopy/CT image registration, and it requires only standard clinical equipment. It is one of two major components needed to achieve endoscopy/CT registration, the second of which is tying the camera path to absolute patient geometry. In addition to this second component, future work will focus on validating our camera tracking algorithm in the presence of clinical imaging features such as patient motion, erratic camera motion, and dynamic scene illumination

  8. Augmented Endoscopic Images Overlaying Shape Changes in Bone Cutting Procedures.

    Science.gov (United States)

    Nakao, Megumi; Endo, Shota; Nakao, Shinichi; Yoshida, Munehito; Matsuda, Tetsuya

    2016-01-01

    In microendoscopic discectomy for spinal disorders, bone cutting procedures are performed in tight spaces while observing a small portion of the target structures. Although optical tracking systems are able to measure the tip of the surgical tool during surgery, the poor shape information available during surgery makes accurate cutting difficult, even if preoperative computed tomography and magnetic resonance images are used for reference. Shape estimation and visualization of the target structures are essential for accurate cutting. However, time-varying shape changes during cutting procedures are still challenging issues for intraoperative navigation. This paper introduces a concept of endoscopic image augmentation that overlays shape changes to support bone cutting procedures. This framework handles the history of the location of the measured drill tip as a volume label and visualizes the remains to be cut overlaid on the endoscopic image in real time. A cutting experiment was performed with volunteers, and the feasibility of this concept was examined using a clinical navigation system. The efficacy of the cutting aid was evaluated with respect to the shape similarity, total moved distance of a cutting tool, and required cutting time. The results of the experiments showed that cutting performance was significantly improved by the proposed framework.

  9. Automatic classification of minimally invasive instruments based on endoscopic image sequences

    Science.gov (United States)

    Speidel, Stefanie; Benzko, Julia; Krappe, Sebastian; Sudra, Gunther; Azad, Pedram; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is nowadays a frequently applied technique and can be regarded as a major breakthrough in surgery. The surgeon has to adopt special operation-techniques and deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To analyze the current situation for context-aware assistance, we need intraoperatively gained sensor data and a model of the intervention. A situation consists of information about the performed activity, the used instruments, the surgical objects, the anatomical structures and defines the state of an intervention for a given moment in time. The endoscopic images provide a rich source of information which can be used for an image-based analysis. Different visual cues are observed in order to perform an image-based analysis with the objective to gain as much information as possible about the current situation. An important visual cue is the automatic recognition of the instruments which appear in the scene. In this paper we present the classification of minimally invasive instruments using the endoscopic images. The instruments are not modified by markers. The system segments the instruments in the current image and recognizes the instrument type based on three-dimensional instrument models.

  10. Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography

    Science.gov (United States)

    Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.

    2004-10-01

    A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.

  11. Mitigating fluorescence spectral overlap in wide-field endoscopic imaging

    Science.gov (United States)

    Hou, Vivian; Nelson, Leonard Y.; Seibel, Eric J.

    2013-01-01

    Abstract. The number of molecular species suitable for multispectral fluorescence imaging is limited due to the overlap of the emission spectra of indicator fluorophores, e.g., dyes and nanoparticles. To remove fluorophore emission cross-talk in wide-field multispectral fluorescence molecular imaging, we evaluate three different solutions: (1) image stitching, (2) concurrent imaging with cross-talk ratio subtraction algorithm, and (3) frame-sequential imaging. A phantom with fluorophore emission cross-talk is fabricated, and a 1.2-mm ultrathin scanning fiber endoscope (SFE) is used to test and compare these approaches. Results show that fluorophore emission cross-talk could be successfully avoided or significantly reduced. Near term, the concurrent imaging method of wide-field multispectral fluorescence SFE is viable for early stage cancer detection and localization in vivo. Furthermore, a means to enhance exogenous fluorescence target-to-background ratio by the reduction of tissue autofluorescence background is demonstrated. PMID:23966226

  12. Comparison of Narrowband Imaging with Autofluorescence Imaging for Endoscopic Visualization of Superficial Squamous Cell Carcinoma Lesions of the Esophagus

    Directory of Open Access Journals (Sweden)

    Haruhisa Suzuki

    2012-01-01

    Full Text Available Aim. To compare narrowband imaging (NBI and autofluorescence imaging (AFI endoscopic visualization for identifying superficial esophageal squamous cell carcinoma (SCC. Methods. Twenty-four patients with superficial esophageal carcinomas diagnosed at previous hospitals were enrolled in this study. Lesions were initially detected using white-light endoscopy and then observed with both NBI and AFI. Endoscopic images documented each method, and three endoscopists experienced in esophageal imaging retrospectively reviewed respective images of histologically confirmed esophageal SCCs. Images were assessed for quality in identifying superficial SCCs and rated as excellent, fair, or poor by the three reviewers with interobserver agreement calculated using kappa (κ statistics. Results. Thirty-one lesions histologically confirmed as superficial esophageal SCCs were detected in 24 patients. NBI images of 27 lesions (87% were rated as excellent, three as fair, and one as poor compared to AFI images of 19 lesions (61% rated as excellent, 10 as fair and two as poor (P<0.05. Moderate interobserver agreement (κ=0.42, 95% CI 0.24–0.60 resulted in NBI while fair agreement (κ=0.35, 95% CI 0.18–0.51 was achieved using AFI. Conclusion. NBI may be more effective than AFI for visualization of esophageal SCC.

  13. Benign submucosal lesions of the stomach and duodenum: Imaging characteristics with endoscopic and pathologic correlation

    International Nuclear Information System (INIS)

    Oh, Jong Young; Nam, Kyung Jin; Choi, Jong Cheol; Cho, Jin Han; Yoon, Seong Kuk; Choi, Sun Seob; Kwon, Hee Jin; Yoon, Jung Hee; Kim, Su Jin

    2008-01-01

    Benign submucosal lesions of the stomach and duodenum are occasionally encountered during endoscopy. But endoscopy has its limitations in the diagnosis and differentiation of these lesions, because submucosal lesions are often difficult to visualize at endoscopy due to minimal change of the overlying mucosa. Furthermore, endoscopic biopsy may not always yield adequate tissue for diagnosis due to the submucosal location of the lesions. For this reason, the role of radiologic imaging is important in the diagnosis of submucosal lesions of the stomach and duodenum. Recent advances in computed tomography (CT) and sonographic technology are helpful in narrowing the differential diagnosis of gastroduodenal submucosal lesions. In contrast to endoscopy and barium studies, CT or ultrasonography (US) provides information about both the gastric wall and the extragastric extent of the disease. Arterial phase contrast enhanced CT enables us to discriminate a mass of submucosal from that of a mucosal origin in the differential diagnosis of gastric or duodenal lesions. Although endoscopic sonography has been considered the better modality in the diagnosis of gastroduodenal submucosal lesions, transabdominal sonography can still be an alternative method to endoscopic sonography in assessing of the origin and character of the submucosal lesions. Some gastroduodenal submucosal lesions have similar radiologic findings that make differentiation difficult. But despite overlaps in radiologic findings, some lesions have characteristic radiologic features that may suggest a specific diagnosis. Knowledge of the differential diagnosis of benign submucosal lesions in the stomach and duodenum may promote correct diagnosis and appropriate treatment

  14. Improved planning of endoscopic sinonasal surgery from 3-dimensional images with Osirix® and stereolithography.

    Science.gov (United States)

    Sánchez-Gómez, Serafín; Herrero-Salado, Tomás F; Maza-Solano, Juan M; Ropero-Romero, Francisco; González-García, Jaime; Ambrosiani-Fernández, Jesús

    2015-01-01

    The high variability of sinonasal anatomy requires the best knowledge of its three-dimensional (3D) conformation to perform surgery more safely and efficiently. The aim of the study was to validate the utility of Osirix® and stereolithography in improving endoscopic sinonasal surgery planning. Osirix® was used as a viewer and Digital Imaging and Communications in Medicine (DICOM) 3D imaging manager to improve planning for 114 sinonasal endoscopic operations with polyposis (86) and chronic rhinosinusitis (CRS) (28). Stereolithography rapid prototyping was used for 7 frontoethmoidal mucoceles. Using Osirix® and stereolithography, a greater number of anatomical structures were identified and this was done faster, with a statistically-significant clinical-radiological correlation (Pvirtual reality, allows surgeons to perform endoscopic sinonasal surgery with greater confidence and in less time than using 2D images. Residents also achieve surgical competence faster, more safely and with fewer complications. This beneficial impact is increased when the surgical team has stereolithography rapid prototyping in more complex cases. Copyright © 2014 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Patología Cérvico-Facial. All rights reserved.

  15. Development of CMOS Imager Block for Capsule Endoscope

    International Nuclear Information System (INIS)

    Shafie, S; Fodzi, F A M; Tung, L Q; Lioe, D X; Halin, I A; Hasan, W Z W; Jaafar, H

    2014-01-01

    This paper presents the development of imager block to be associated in a capsule endoscopy system. Since the capsule endoscope is used to diagnose gastrointestinal diseases, the imager block must be in small size which is comfortable for the patients to swallow. In this project, a small size 1.5 V button battery is used as the power supply while the voltage supply requirements for other components such as microcontroller and CMOS image sensor are higher. Therefore, a voltage booster circuit is proposed to boost up the voltage supply from 1.5 V to 3.3 V. A low power microcontroller is used to generate control pulses for the CMOS image sensor and to convert the 8-bits parallel data output to serial data to be transmitted to the display panel. The results show that the voltage booster circuit was able to boost the voltage supply from 1.5 V to 3.3 V. The microcontroller precisely controls the CMOS image sensor to produce parallel data which is then serialized again by the microcontroller. The serial data is then successfully translated to 2fps image and displayed on computer.

  16. Endoscopic Cerenkov luminescence imaging: in vivo small animal tumor model validation

    Science.gov (United States)

    Song, Tianming; Bao, Chengpeng; Hu, Zhenhua; Wang, Kun; Liu, Xia; Tian, Jie

    2015-03-01

    Background: Cerenkov luminescence imaging (CLI) provides a great potential for clinical translation of optical molecular imaging techniques through using clinical approved radiotracers. However, it is difficult to obtain the Cerenkov luminescence signal of deeper biological tissues due to the small magnitude of the signal. To efficiently acquire the weak Cerenkov luminescence, we developed an endoscopic Cerenkov luminescence imaging (ECLI) system to reduce the in vivo imaging depth with minimum invasion, and validated the system on small animal tumor models. Methods: For the ECLI system, the laparoscope was connected to a high sensitive charge-couple device (CCD) camera (DU888+, Andor, UK) by a custom made adapter. We conducted a series of in vitro and in vivo experiments by use of the system. In the in vitro experiment, the endoscopic luminescence images of the 18F-FDG with various activities in EP tubes were acquired using ECLI system, and the sensitivity was compared with conventional CLI system. In the in vivo tumor experiment, 18F-FDG with the activity of 200μCi were intravenously injected into 3 tumor mice. Then the ECLI system was used to acquire the optical images for both non-invasive and invasive conditions. Conclusion: Experimental data showed the ECLI system could detect the 18F-FDG with the activity as low as 1μCi. Furthermore, our preliminary results indicated the possibility of ECLI technique for detecting Cerenkov signals inside the tumor tissue with deeper depth and guiding the surgical operation of tumor excision. We believe that this technique can help to accelerate the clinical translation of CLI.

  17. Modelling of a laser-pumped light source for endoscopic surgery

    Science.gov (United States)

    Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.

    2008-09-01

    A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.

  18. Method for radiometric calibration of an endoscope's camera and light source

    Science.gov (United States)

    Rai, Lav; Higgins, William E.

    2008-03-01

    An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.

  19. Optical design of an optical coherence tomography and multispectral fluorescence imaging endoscope to detect early stage ovarian cancer

    Science.gov (United States)

    Tate, Tyler; Keenan, Molly; Swan, Elizabeth; Black, John; Utzinger, Urs; Barton, Jennifer

    2014-12-01

    The five year survival rate for ovarian cancer is over 90% if early detection occurs, yet no effective early screening method exists. We have designed and are constructing a dual modality Optical Coherence Tomography (OCT) and Multispectral Fluorescence Imaging (MFI) endoscope to optically screen the Fallopian tube and ovary for early stage cancer. The endoscope reaches the ovary via the natural pathway of the vagina, cervix, uterus and Fallopian tube. In order to navigate the Fallopian tube the endoscope must have an outer diameter of 600 μm, be highly flexible, steerable, tracking and nonperforating. The imaging systems consists of six optical subsystems, two from OCT and four from MFI. The optical subsystems have independent and interrelated design criteria. The endoscope will be tested on realistic tissue models and ex vivo tissue to prove feasibility of future human trials. Ultimately the project aims to provide women the first effective ovarian cancer screening technique.

  20. Emphysema. Imaging for endoscopic lung volume reduction; Lungenemphysem. Bildgebung bei endoskopischer Lungenvolumenreduktion

    Energy Technology Data Exchange (ETDEWEB)

    Storbeck, B. [LungenClinic Grosshansdorf (Germany). Dept. of Radiology; Schroeder, T.H. [Amalie Sieveking-Hospital, Diagnostic and Interventional Radiology, Hamburg (Germany); Oldigs, M.; Rabe, K.F. [LungenClinic Grosshansdorf (Germany). Dept. of Pulmonology; Weber, C. [Amalie Sieveking-Hospital, Diagnostic and Interventional Radiology, Hamburg (Germany); University Medical Center Hamburg-Eppendorf (Germany). Diagnostic and Interventional Radiology

    2015-07-15

    Chronic obstructive pulmonary disease (COPD) is characterized by two entities, the more airway-predominant type (''bronchitis'') on the one hand, and emphysema-predominant type on the other. Imaging via high-resolution computed tomography plays an important role in phenotyping COPD. For patients with advanced lung emphysema, new endoscopic lung volume reduction therapies (ELVR) have been developed. Proper selection of suitable patients requires thin-section reconstruction of volumetric CT image data sets also in coronal and sagittal orientation are required. In the current manuscript we will describe emphysema subtypes (centrilobular, paraseptal, panlobular), options for quantifying emphysema and this importance of regional distribution (homogeneous or heterogeneous, target area) as this is crucial for patient selection. Analysis of the interlobular fissures is obligatory despite the lack of standardization, as incomplete fissures indicate collateral ventilation (CV) via parenchymal bridges, which is an important criterion in choosing endoscopic methods of LVR. Every radiologist should be familiar with modern LVR therapies such as valves and coils, and furthermore should know what a lung doctor expects from radiologic evaluation (before and after ELVR). Finally we present a checklist as a quick reference for all steps concerning imaging for ELVR.

  1. A novel fusion imaging system for endoscopic ultrasound

    DEFF Research Database (Denmark)

    Gruionu, Lucian Gheorghe; Saftoiu, Adrian; Gruionu, Gabriel

    2016-01-01

    BACKGROUND AND OBJECTIVE: Navigation of a flexible endoscopic ultrasound (EUS) probe inside the gastrointestinal (GI) tract is problematic due to the small window size and complex anatomy. The goal of the present study was to test the feasibility of a novel fusion imaging (FI) system which uses...... time was 24.6 ± 6.6 min, while the time to reach the clinical target was 8.7 ± 4.2 min. CONCLUSIONS: The FI system is feasible for clinical use, and can reduce the learning curve for EUS procedures and improve navigation and targeting in difficult anatomic locations....

  2. A Panoramic Wireless Endoscope System Design for the Application of Minimally Invasive Surgery

    Directory of Open Access Journals (Sweden)

    Chun-Hsiang Peng

    2014-05-01

    Full Text Available Minimally Invasive Surgery (MIS is the current trend in surgery. Compared to traditional surgery, MIS can substantially decrease recovery time and expenses needed by patients after surgeries, reduce pain during surgical procedures, and is highly regarded by physicians and patients. An endoscope is widely used in the diagnosis and treatments of various medical disciplines, such as hysteroscopy, laparoscopy, and colonoscopy, and have been adopted by many branches of medicine. However, the limited image field of MIS is often the most difficult obstacles faced by surgeons and medical students, especially to less experienced physicians and difficult surgical procedures; the limited field of view of endoscopic imaging does not provide a whole picture of the surgery area, making the procedures difficult and full of uncertainty. In light of this problem, we proposed a "Panoramic Wireless Endoscope System design", hoping to provide physicians with a wide field of view of the endoscopic image. We combine images captured from two parallel-mounted endoscope lenses into a single, wide-angle image, giving physicians a wider field of view and easier access to the surgical area. In addition, we developed a wireless transmission system so the image can be transmitted to various display platforms, eliminating the needs for excessive cabling on surgical tools and enable physicians to better operate on the patient. Finally, our system allows surgical assistants a better view of the operation process, and enables other physicians and nurses to remotely observe the process. Our experiment results have shown that we can increase the image to 152% of its original size. We used the PandaBoard ES platform with an ARM9 processor and 1G of onboard RAM, and continuously implementing animal trials to verify the reliability of our system.

  3. A discriminative structural similarity measure and its application to video-volume registration for endoscope three-dimensional motion tracking.

    Science.gov (United States)

    Luo, Xiongbiao; Mori, Kensaku

    2014-06-01

    Endoscope 3-D motion tracking, which seeks to synchronize pre- and intra-operative images in endoscopic interventions, is usually performed as video-volume registration that optimizes the similarity between endoscopic video and pre-operative images. The tracking performance, in turn, depends significantly on whether a similarity measure can successfully characterize the difference between video sequences and volume rendering images driven by pre-operative images. The paper proposes a discriminative structural similarity measure, which uses the degradation of structural information and takes image correlation or structure, luminance, and contrast into consideration, to boost video-volume registration. By applying the proposed similarity measure to endoscope tracking, it was demonstrated to be more accurate and robust than several available similarity measures, e.g., local normalized cross correlation, normalized mutual information, modified mean square error, or normalized sum squared difference. Based on clinical data evaluation, the tracking error was reduced significantly from at least 14.6 mm to 4.5 mm. The processing time was accelerated more than 30 frames per second using graphics processing unit.

  4. Progress in Molecular Imaging in Endoscopy and Endomicroscopy for Cancer Imaging

    Directory of Open Access Journals (Sweden)

    Supang Khondee

    2013-01-01

    Full Text Available Imaging is an essential tool for effective cancer management. Endoscopes are important medical instruments for performing in vivo imaging in hollow organs. Early detection of cancer can be achieved with surveillance using endoscopy, and has been shown to reduce mortality and to improve outcomes. Recently, great advancements have been made in endoscopic instruments, including new developments in optical designs, light sources, optical fibers, miniature scanners, and multimodal systems, allowing for improved resolution, greater tissue penetration, and multispectral imaging. In addition, progress has been made in the development of highly-specific optical probes, allowing for improved specificity for molecular targets. Integration of these new endoscopic instruments with molecular probes provides a unique opportunity for significantly improving patient outcomes and has potential to further improve early detection, image guided therapy, targeted therapy, and personalized medicine. This work summarizes current and evolving endoscopic technologies, and provides an overview of various promising optical molecular probes.

  5. High resolution axicon-based endoscopic FD OCT imaging with a large depth range

    Science.gov (United States)

    Lee, Kye-Sung; Hurley, William; Deegan, John; Dean, Scott; Rolland, Jannick P.

    2010-02-01

    Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF). This optics could accommodate for varying sizes of tubular structures across patients and along the tree within a single patient. In the paper, we demonstrate an extended DOF without sacrificing resolution showing rotational images in biological tubular samples with 2.5 μm axial resolution, 10 ìm lateral resolution, and > 4 mm depth range using a custom designed probe.

  6. Early Use of Magnetic Endoscopic Imaging by Novice Colonoscopists: Improved Performance without Increase in Workload

    Directory of Open Access Journals (Sweden)

    Sylvain Coderre

    2010-01-01

    Full Text Available BACKGROUND: Magnetic endoscopic imaging represents a recent advance in colonoscopy training. This technique provides adjunct information to the endoscopist, specifically with regard to colonoscope loop formation.

  7. First Application of 7T Magnetic Resonance Imaging in Endoscopic Endonasal Surgery of Skull Base Tumors

    Science.gov (United States)

    Barrett, Thomas F; Dyvorne, Hadrien A; Padormo, Francesco; Pawha, Puneet S; Delman, Bradley N; Shrivastava, Raj K; Balchandani, Priti

    2018-01-01

    Background Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of skull base. In this study, we apply a 7T imaging protocol to patients with skull base tumors and compare the images to clinical standard of care. Methods Images were acquired at 7T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5T, 3T, and 7T scans for detection of intracavernous cranial nerves and ICA branches. Detection rates were compared. Images were utilized for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. Results Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7T. 7T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. Conclusion Our study represents the first application of 7T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7T MRI compared to 3T and 1.5 T, and found that integration of 7T into surgical planning and guidance was feasible. These results suggest a potential for 7T MRI to reduce surgical complications. Future studies comparing standardized 7T, 3T, and 1.5 T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7T MRI for endonasal endoscopic surgical efficacy. PMID:28359922

  8. First Application of 7-T Magnetic Resonance Imaging in Endoscopic Endonasal Surgery of Skull Base Tumors.

    Science.gov (United States)

    Barrett, Thomas F; Dyvorne, Hadrien A; Padormo, Francesco; Pawha, Puneet S; Delman, Bradley N; Shrivastava, Raj K; Balchandani, Priti

    2017-07-01

    Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7-T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of the skull base. In this study, we apply a 7-T imaging protocol to patients with skull base tumors and compare the images with clinical standard of care. Images were acquired at 7 T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5-, 3-, and 7-T scans for detection of intracavernous cranial nerves and internal carotid artery (ICA) branches. Detection rates were compared. Images were used for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7 T. The 7-T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. Our study represents the first application of 7-T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7-T MRI compared with 3- and 1.5-T MRI, and found that integration of 7 T into surgical planning and guidance was feasible. These results suggest a potential for 7-T MRI to reduce surgical complications. Future studies comparing standardized 7-, 3-, and 1.5-T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7-T MRI for endonasal endoscopic surgical efficacy. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Development of an image processing system at the Technology Applications Center, UNM: Landsat image processing in mineral exploration and related activities. Final report

    International Nuclear Information System (INIS)

    Budge, T.K.

    1980-09-01

    This project was a demonstration of the capabilities of Landsat satellite image processing applied to the monitoring of mining activity in New Mexico. Study areas included the Navajo coal surface mine, the Jackpile uranium surface mine, and the potash mining district near Carlsbad, New Mexico. Computer classifications of a number of land use categories in these mines were presented and discussed. A literature review of a number of case studies concerning the use of Landsat image processing in mineral exploration and related activities was prepared. Included in this review is a discussion of the Landsat satellite system and the basics of computer image processing. Topics such as destriping, contrast stretches, atmospheric corrections, ratioing, and classification techniques are addressed. Summaries of the STANSORT II and ELAS software packages and the Technology Application Center's Digital Image Processing System (TDIPS) are presented

  10. Training course on optical telecommunication and multimedia technologies for specialists in endoscopic video surgery

    Science.gov (United States)

    Agliullin, Arthur F.; Gusev, Valery F.; Morozov, Oleg G.; Samigullin, Rustem R.; Akul'shin, Alexander, Iv.; Bagapov, Nail N.

    2011-04-01

    The program of courses is recommended for the experts working in endoscopy area, surgery, diagnostics, to developers of optical, optoelectronic and electronic equipment, and also for students and the post-graduate students of telecommunication high schools in addition trained on specializations of biomedical engineering. It urged to help the future researcher, engineer and doctor to understand mechanisms of images formation and display, to understand more deeply procedures of their processing and transfer on telecommunication channels of the various natures, to master modern reports of record and video and audio information reproduction. The separate section is devoted to questions of designing of surgical toolkit compatible with fiber-optical endoscopes.

  11. Scoping the scope: endoscopic evaluation of endoscope working channels with a new high-resolution inspection endoscope (with video).

    Science.gov (United States)

    Barakat, Monique T; Girotra, Mohit; Huang, Robert J; Banerjee, Subhas

    2018-02-06

    Outbreaks of transmission of infection related to endoscopy despite reported adherence to reprocessing guidelines warrant scrutiny of all potential contributing factors. Recent reports from ambulatory surgery centers indicated widespread significant occult damage within endoscope working channels, raising concerns regarding the potential detrimental impact of this damage on the adequacy of endoscope reprocessing. We inspected working channels of all 68 endoscopes at our academic institution using a novel flexible inspection endoscope. Inspections were recorded and videos reviewed by 3 investigators to evaluate and rate channel damage and/or debris. Working channel rinsates were obtained from all endoscopes, and adenosine triphosphate (ATP) bioluminescence was measured. Overall endoscope working channel damage was rated as minimal and/or mild and was consistent with expected wear and tear (median 1.59 on our 5-point scale). Our predominant findings included superficial scratches (98.5%) and scratches with adherent peel (76.5%). No channel perforations, stains, or burns were detected. The extent of damage was not predicted by endoscope age. Minor punctate debris was common, and a few small drops of fluid were noted in 42.6% of endoscopes after reprocessing and drying. The presence of residual fluid predicted higher ATP bioluminescence values. The presence of visualized working channel damage or debris was not associated with elevated ATP bioluminescence values. The flexible inspection endoscope enables high-resolution imaging of endoscope working channels and offers endoscopy units an additional modality for endoscope surveillance, potentially complementing bacterial cultures and ATP values. Our study, conducted in a busy academic endoscopy unit, indicated predominately mild damage to endoscope working channels, which did not correlate with elevated ATP values. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights

  12. Markov Processes in Image Processing

    Science.gov (United States)

    Petrov, E. P.; Kharina, N. L.

    2018-05-01

    Digital images are used as an information carrier in different sciences and technologies. The aspiration to increase the number of bits in the image pixels for the purpose of obtaining more information is observed. In the paper, some methods of compression and contour detection on the basis of two-dimensional Markov chain are offered. Increasing the number of bits on the image pixels will allow one to allocate fine object details more precisely, but it significantly complicates image processing. The methods of image processing do not concede by the efficiency to well-known analogues, but surpass them in processing speed. An image is separated into binary images, and processing is carried out in parallel with each without an increase in speed, when increasing the number of bits on the image pixels. One more advantage of methods is the low consumption of energy resources. Only logical procedures are used and there are no computing operations. The methods can be useful in processing images of any class and assignment in processing systems with a limited time and energy resources.

  13. Technology insight: endoscopic submucosal dissection of gastrointestinal neoplasms.

    Science.gov (United States)

    Yamamoto, Hironori

    2007-09-01

    Gastrointestinal neoplasms can be cured by local resection as long as the lesions are in the early stage and have not metastasized. Endoscopic resection is a minimally invasive treatment for early-stage gastrointestinal neoplasms, and endoscopic submucosal dissection (ESD) is one type of endoscopic resection that has been developed in the past 10 years. For ESD to be a reliable, curative treatment for gastrointestinal neoplasms, it is necessary for the endoscopist to detect the lesion early, make a precise pretreatment diagnosis, ensure that the patient has the correct indication for endoscopic resection, and have the skill to perform ESD. For early lesion detection, endoscopists should pay attention to subtle changes in the surface structure, the color of the mucosa and the visibility of underlying submucosal vessels. Chromoendoscopy and magnifying endoscopy are useful for determining the margin of the lesions for pretreatment diagnosis, and endoscopic ultrasonography and magnifying endoscopy are useful for determining the depth of invasion. For ESD to be successful, local injection of sodium hyaluronate helps maintain mucosal elevation during dissection. Selecting the appropriate knife, using transparent hoods wisely, employing a good strategy that uses gravity, and having good control of bleeding are all needed to make ESD reliable.

  14. Endoscopic Devices for Obesity.

    Science.gov (United States)

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  15. Endoscopic tri-modal imaging for detection of early neoplasia in Barrett's oesophagus: a multi-centre feasibility study using high-resolution endoscopy, autofluorescence imaging and narrow band imaging incorporated in one endoscopy system

    NARCIS (Netherlands)

    Curvers, W. L.; Singh, R.; Song, L.-M. Wong-Kee; Wolfsen, H. C.; Ragunath, K.; Wang, K.; Wallace, M. B.; Fockens, P.; Bergman, J. J. G. H. M.

    2008-01-01

    OBJECTIVE: To investigate the diagnostic potential of endoscopic tri-modal imaging and the relative contribution of each imaging modality (i.e. high-resolution endoscopy (HRE), autofluorescence imaging (AFI) and narrow-band imaging (NBI)) for the detection of early neoplasia in Barrett's oesophagus.

  16. Frontiers in medical imaging technology

    International Nuclear Information System (INIS)

    Iinuma, Takeshi

    1992-01-01

    At present many medical images are used for diagnostics and treatment. After the advent of X-ray computer tomography (XCT), the violent development of medical images has continued. Medical imaging technology can be defined as the field of technology that deals with the production, processing, display, transmission, evaluation and so on of medical images, and it can be said that the present development of medical imaging diagnostics has been led by medical imaging technology. In this report, the most advanced technology of medical imaging is explained. The principle of XCT is shown. The feature of XCT is that it can image the delicate difference in the X-ray absorption factor of the cross section being measured. The technical development has been advanced to reduce the time for imaging and to heighten the resolution. The technology which brings about a large impact to future imaging diagnostics is computed radiography. Magnetic resonance imaging is the method of imaging the distribution of protons in human bodies. Positron CT is the method of measurement by injecting a positron-emitting RI. These methods are explained. (K.I.)

  17. Robot-assisted endoscope guidance versus manual endoscope guidance in functional endonasal sinus surgery (FESS).

    Science.gov (United States)

    Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten

    2017-10-01

    Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.

  18. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  19. Mirizzi Syndrome with Endoscopic Ultrasound Image

    Directory of Open Access Journals (Sweden)

    K. Rayapudi

    2013-05-01

    Full Text Available We describe a 66-year-old Caucasian man with type 1 Mirizzi syndrome diagnosed on endoscopic ultrasound. He presented with acute onset of jaundice, malaise, dark urine over 3-4 days, and was found to have obstructive jaundice on lab testing. CT scan of the abdomen showed intrahepatic biliary ductal dilation, a 1.5 cm common bile duct (CBD above the pancreas, and possible stones in the CBD, but no masses. Endoscopic retrograde cholangiopancreatography (ERCP by a community gastroenterologist failed to cannulate the CBD. At the University Center, type 1 Mirizzi syndrome was noted on endoscopic ultrasound with narrowing of the CBD with extrinsic compression from cystic duct stone. During repeat ERCP, the CBD could be cannulated over the pancreatic duct wire. A mid CBD narrowing, distal CBD stones, proximal CBD and extrahepatic duct dilation were noted, and biliary sphincterotomy was performed. A small stone in the distal CBD was removed with an extraction balloon. The cystic duct stone was moved with the biliary balloon into the CBD, mechanical basket lithotripsy was performed and stone fragments were delivered out with an extraction balloon. The patient was seen 7 weeks later in the clinic. Skin and scleral icterus had cleared up and he is scheduled for an elective cholecystectomy. Mirizzi syndrome refers to biliary obstruction resulting from impacted stone in the cystic duct or neck of the gallbladder and commonly presents with obstructive jaundice. Type 1 does not have cholecystocholedochal fistulas, but they present in types 2, 3 and 4. Surgery is the mainstay of therapy. Endoscopic treatment is effective and can also be used as a temporizing measure or definitive treatment in poor surgical risk candidates.

  20. Full image-processing pipeline in field-programmable gate array for a small endoscopic camera

    Science.gov (United States)

    Mostafa, Sheikh Shanawaz; Sousa, L. Natércia; Ferreira, Nuno Fábio; Sousa, Ricardo M.; Santos, Joao; Wäny, Martin; Morgado-Dias, F.

    2017-01-01

    Endoscopy is an imaging procedure used for diagnosis as well as for some surgical purposes. The camera used for the endoscopy should be small and able to produce a good quality image or video, to reduce discomfort of the patients, and to increase the efficiency of the medical team. To achieve these fundamental goals, a small endoscopy camera with a footprint of 1 mm×1 mm×1.65 mm is used. Due to the physical properties of the sensors and human vision system limitations, different image-processing algorithms, such as noise reduction, demosaicking, and gamma correction, among others, are needed to faithfully reproduce the image or video. A full image-processing pipeline is implemented using a field-programmable gate array (FPGA) to accomplish a high frame rate of 60 fps with minimum processing delay. Along with this, a viewer has also been developed to display and control the image-processing pipeline. The control and data transfer are done by a USB 3.0 end point in the computer. The full developed system achieves real-time processing of the image and fits in a Xilinx Spartan-6LX150 FPGA.

  1. Advanced microlens and color filter process technology for the high-efficiency CMOS and CCD image sensors

    Science.gov (United States)

    Fan, Yang-Tung; Peng, Chiou-Shian; Chu, Cheng-Yu

    2000-12-01

    New markets are emerging for digital electronic image device, especially in visual communications, PC camera, mobile/cell phone, security system, toys, vehicle image system and computer peripherals for document capture. To enable one-chip image system that image sensor is with a full digital interface, can make image capture devices in our daily lives. Adding a color filter to such image sensor in a pattern of mosaics pixel or wide stripes can make image more real and colorful. We can say 'color filter makes the life more colorful color filter is? Color filter means can filter image light source except the color with specific wavelength and transmittance that is same as color filter itself. Color filter process is coating and patterning green, red and blue (or cyan, magenta and yellow) mosaic resists onto matched pixel in image sensing array pixels. According to the signal caught from each pixel, we can figure out the environment image picture. Widely use of digital electronic camera and multimedia applications today makes the feature of color filter becoming bright. Although it has challenge but it is very worthy to develop the process of color filter. We provide the best service on shorter cycle time, excellent color quality, high and stable yield. The key issues of advanced color process have to be solved and implemented are planarization and micro-lens technology. Lost of key points of color filter process technology have to consider will also be described in this paper.

  2. FY1995 development of a endoscopic surgical system utilizing multi-modal functional images; 1995 nendo tashu kino gazo wo mochiiru teishinshu naishikyo shujutsu system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The purpose of this study is to develop an endoscope system for neurosurgery that can provide not only conventional endoscopic images but also ultraviolet-visible spectra, fluorescence spectra, near infrared spectra, and ultra-soundimages of tissue aiming for real-time identification of pathological tissue. The system also incorporates surgical manipulator and devices such as micro forceps and laser surgical instruments for endoscopic image guided surgery. Surgical Manipulator should be a high performance and easy to operate surgical instrument as well as conventional surgical tools such as scissors and knife. Since living tissue deforms during surgical operation, pre-operative three dimensional information for registration of pathological tissue should be modified based on information obtained during surgery. Thus surgical manipulator should be operated under guidance of surgeon's observation. Consequently, surgical manipulator should have various types of imaging and measurement devices such as an endoscope and an ultrasound imaging probe at its end effectors. Based on this concept, a prototype of a new multi channel surgical manipulator system CM cube (CM3, Computer aided Micro Multichannel Manipulator) that has various types of imaging and measurement devices such as ultra-violet-visible camera for spectroscopic measurement, ultra-sound imaging probe, three dimensional endoscope, together with micro surgical instruments and laser surgical systems has been developed. Its performance was evaluated through in vitro/in vivo experiments and clinical application. (NEDO)

  3. [Natural Orifice Transluminal Endoscopic Surgery (NOTES)].

    Science.gov (United States)

    Kim, Yong Sik; Kim, Chul Young; Chun, Hoon Jai

    2008-03-01

    Recently, the field of gastrointestinal endoscopy is developing rapidly. Once limited to the gastroinstestinal lumen, the endoscopic technology is now breaking the barriers and extending its boundary to peritoneal and pleural space. In 2004, Dr. Kalloo, a gastroenterologist, observed intraperitoneal organs of a pig using a conventional endoscope through the stomach wall. Since then, new endoscopic technique of intraperitoneal intervention with transluminal approach named the Natural Orifice Transluminal Endoscopic Surgery or NOTES has been introduced. NOTES reaches the target organ by inserting the endoscope through a natural orifice (e.g. mouth, anus, vagina, urethra) and entering the peritoneal lumen by means of making an incision on the luminal wall. After a series of successful experiences in animal studies, NOTES are now being tried on human subjects. There are still many obstacles to overcome, but bright future for this new technology is expected because of its proposed advantages of less pain, lower complication rate, short recovery time, and scarless access. In this review, we plan to learn about NOTES.

  4. Direct navigation on 3D rotational x-ray data acquired with a mobile propeller C-arm: accuracy and application in functional endoscopic sinus surgery

    International Nuclear Information System (INIS)

    Kraats, Everine B van de; Carelsen, Bart; Fokkens, Wytske J; Boon, Sjirk N; Noordhoek, Niels; Niessen, Wiro J; Walsum, Theo van

    2005-01-01

    Recently, three-dimensional (3D) rotational x-ray imaging has been combined with navigation technology, enabling direct 3D navigation for minimally invasive image guided interventions. In this study, phantom experiments are used to determine the accuracy of such a navigation set-up for a mobile C-arm with propeller motion. After calibration of the C-arm system, the accuracy is evaluated by pinpointing divots on a special-purpose phantom with known geometry. This evaluation is performed both with and without C-arm motion in between calibration and registration for navigation. The variation caused by each of the individual transformations in the calibration and registration process is also studied. The feasibility of direct navigation on 3D rotational x-ray images for functional endoscopic sinus surgery has been evaluated in a cadaver navigation experiment. Navigation accuracy was approximately 1.0 mm, which is sufficient for functional endoscopic sinus surgery. C-arm motion in between calibration and registration slightly degraded the registration accuracy by approximately 0.3 mm. Standard deviations of each of the transformations were in the range 0.15-0.31 mm. In the cadaver experiment, the navigation images were considered in good correspondence with the endoscopic images by an experienced ENT surgeon. Availability of 3D localization information provided by the navigation system was considered valuable by the ENT surgeon

  5. Visual servoing in medical robotics: a survey. Part I: endoscopic and direct vision imaging - techniques and applications.

    Science.gov (United States)

    Azizian, Mahdi; Khoshnam, Mahta; Najmaei, Nima; Patel, Rajni V

    2014-09-01

    Intra-operative imaging is widely used to provide visual feedback to a clinician when he/she performs a procedure. In visual servoing, surgical instruments and parts of tissue/body are tracked by processing the acquired images. This information is then used within a control loop to manoeuvre a robotic manipulator during a procedure. A comprehensive search of electronic databases was completed for the period 2000-2013 to provide a survey of the visual servoing applications in medical robotics. The focus is on medical applications where image-based tracking is used for closed-loop control of a robotic system. Detailed classification and comparative study of various contributions in visual servoing using endoscopic or direct visual images are presented and summarized in tables and diagrams. The main challenges in using visual servoing for medical robotic applications are identified and potential future directions are suggested. 'Supervised automation of medical robotics' is found to be a major trend in this field. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer

    Science.gov (United States)

    Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.

    2018-02-01

    Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.

  7. The establishment of enteral nutrition with minimally-invasive interventional procedure under endoscopic or imaging guidance

    International Nuclear Information System (INIS)

    Li Feng; Cheng Yingsheng

    2010-01-01

    For patients unable to get the necessary nutrition orally, a variety of techniques,including surgical way, to make gastrostomy with tube placement have been employed. For recent years, gastrostomy and tube placement with the help of endoscopic guidance or percutaneous interventional management has been developed, which is superior to surgical procedure in minimizing injuries, decreasing cost and reducing complications. In certain clinical situations, both endoscopic method and interventional method can be employed. This paper aims to make a comprehensive review of the indications, techniques and skills, advantages and disadvantages of both the endoscopy-guided and the imaging-guided percutaneous gastrojejunostomy for the establishment of enteral nutrition. (authors)

  8. Invitation to medical image processing

    International Nuclear Information System (INIS)

    Kitasaka, Takayuki; Suenaga, Yasuhito; Mori, Kensaku

    2010-01-01

    This medical essay explains the present state of CT image processing technology about its recognition, acquisition and visualization for computer-assisted diagnosis (CAD) and surgery (CAS), and future view. Medical image processing has a series of history of its original start from the discovery of X-ray to its application to diagnostic radiography, its combination with the computer for CT, multi-detector raw CT, leading to 3D/4D images for CAD and CAS. CAD is performed based on the recognition of normal anatomical structure of human body, detection of possible abnormal lesion and visualization of its numerical figure into image. Actual instances of CAD images are presented here for chest (lung cancer), abdomen (colorectal cancer) and future body atlas (models of organs and diseases for imaging), a recent national project: computer anatomy. CAS involves the surgical planning technology based on 3D images, navigation of the actual procedure and of endoscopy. As guidance to beginning technological image processing, described are the national and international community like related academic societies, regularly conducting congresses, textbooks and workshops, and topics in the field like computed anatomy of an individual patient for CAD and CAS, its data security and standardization. In future, protective medicine is in authors' view based on the imaging technology, e.g., daily life CAD of individuals ultimately, as exemplified in the present body thermometer and home sphygmometer, to monitor one's routine physical conditions. (T.T.)

  9. Re-engineering the process of medical imaging physics and technology education and training.

    Science.gov (United States)

    Sprawls, Perry

    2005-09-01

    The extensive availability of digital technology provides an opportunity for enhancing both the effectiveness and efficiency of virtually all functions in the process of medical imaging physics and technology education and training. This includes degree granting academic programs within institutions and a wide spectrum of continuing education lifelong learning activities. Full achievement of the advantages of technology-enhanced education (e-learning, etc.) requires an analysis of specific educational activities with respect to desired outcomes and learning objectives. This is followed by the development of strategies and resources that are based on established educational principles. The impact of contemporary technology comes from its ability to place learners into enriched learning environments. The full advantage of a re-engineered and implemented educational process involves changing attitudes and functions of learning facilitators (teachers) and resource allocation and sharing both within and among institutions.

  10. Systems workplace for endoscopic surgery.

    Science.gov (United States)

    Irion, K M; Novak, P

    2000-01-01

    With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.

  11. Duodenal endoscopic findings and histopathologic confirmation of intestinal lymphangiectasia in dogs.

    Science.gov (United States)

    Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S

    2012-01-01

    The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  12. Endoscopic Laser-Based 3D Imaging for Functional Voice Diagnostics

    Directory of Open Access Journals (Sweden)

    Marion Semmler

    2017-06-01

    Full Text Available Recently, we reported on the in vivo application of a miniaturized measuring device for 3D visualization of the superior vocal fold vibrations from high-speed recordings in combination with a laser projection unit (LPU. As a long-term vision for this proof of principle, we strive to integrate the further developed laserendoscopy as a diagnostic method in daily clinical routine. The new LPU mainly comprises a Nd:YAG laser source (532 nm/CW/2 ω and a diffractive optical element (DOE generating a regular laser grid (31 × 31 laser points that is projected on the vocal folds. By means of stereo triangulation, the 3D coordinates of the laser points are reconstructed from the endoscopic high-speed footage. The new design of the laserendoscope constitutes a compromise between robust image processing and laser safety regulations. The algorithms for calibration and analysis are now optimized with respect to their overall duration and the number of required interactions, which is objectively assessed using binary classifiers. The sensitivity and specificity of the calibration procedure are increased by 40.1% and 22.3%, which is statistically significant. The overall duration for the laser point detection is reduced by 41.9%. The suggested semi-automatic reconstruction software represents an important stepping-stone towards potential real time processing and a comprehensive, objective diagnostic tool of evidence-based medicine.

  13. Study on multi-detector computed tomography in the virtual endoscope mode to phantom of saliva gland duct application. Image quality evaluation of geometry

    International Nuclear Information System (INIS)

    Ozawa, Tomonori; Innami, Hisashi; Oyake, Reira; Shinohara, Yuki; Yamaaki, Fumi; Koizumi, Nobuhide; Okumura, Yasuhiko

    2009-01-01

    The diagnosis ability of the radiographic imaging has been greatly improved by the advent of multi-detector computed tomography (MDCT), Which is now a the prerequisite to the diagnosis and treatment of a variety of diseases. MDCT conducted in the virtual endoscope mode can be used for various image compositions, and the space in a structure such as the large intestines can be visualized similarly as with an actual endoscope. Using a phantom of a salivary gland duct, I performed the image analysis to determine whether this endoscope mode could able to be applied to the oral cavity. I searched for the optimum conditions and the best position for taking pictures, and evaluated whether the salivary gland ducts could be reproducibly imitated by the phantom. Modulation transfer function (MTF), Wiener spectrum (WS) analysis were used to examined the utility of MDCT in the virtual endoscope mode for use in the oral cavity. As a result, the following conclusions were made: The best image was obtained within 40 mm from the center part of the gantry by the MTF and the WS analyses. Decreases in the MTF and the WS as the decrease were seen at 20 mAs and 80 kV, and the decrease were seen in the sharpness of the image decreased as the value of the reconstruction function became smaller. The image was somewhat distorted when pictures were taken of the parallel or the direction of the slice by the inclination within 90 deg±15 deg as much as possible Z axially for running of the duct in the evaluation of internal reproducibility. The influence was admitted to go out easily in an inside form as the inside diameter became thin. The salivary gland phantom was evaluated geometrically by MDCT in the virtual endoscope mode, and the optimal conditions were obtained from the above-mentioned results. The utility of MDCT in the mode was thus suggested. (author)

  14. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  15. Therapeutic aspects of endoscopic ultrasound

    Science.gov (United States)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  16. Three-dimensional imaging technology offers promise in medicine.

    Science.gov (United States)

    Karako, Kenji; Wu, Qiong; Gao, Jianjun

    2014-04-01

    Medical imaging plays an increasingly important role in the diagnosis and treatment of disease. Currently, medical equipment mainly has two-dimensional (2D) imaging systems. Although this conventional imaging largely satisfies clinical requirements, it cannot depict pathologic changes in 3 dimensions. The development of three-dimensional (3D) imaging technology has encouraged advances in medical imaging. Three-dimensional imaging technology offers doctors much more information on a pathology than 2D imaging, thus significantly improving diagnostic capability and the quality of treatment. Moreover, the combination of 3D imaging with augmented reality significantly improves surgical navigation process. The advantages of 3D imaging technology have made it an important component of technological progress in the field of medical imaging.

  17. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  18. MR imaging of colorectal carcinomas using an MR endoscopic coil

    International Nuclear Information System (INIS)

    Murano, Akihiko; Kido, Choichiro; Sasaki, Fumio; Nakamura, Tsuneya; Kobayashi, Semi; Katoh, Tomoyuki; Hirai, Takashi

    1994-01-01

    Diagnosis of the depth of wall invasion by rectal carcinoma using MR endoscopy was performed in ten resected specimens, including five rectal carcinomas, three colon carcinomas, two normal gastric wall. In addition, the gastric wall of a pig was examined. MR imaging was done with a 1.5-T Signa Advantage (GE Medical System) system, with the surface coil of the MR endoscope acting as the receiver coil. Five layers could be distinguished in the bowel wall: mucosa, submucosa and muscularis propria divided into circular muscle, longitudinal muscle and intervening connective tissue. Tumors had almost the same signal intensity as muscle. The MR images of colon carcinomas, rectal carcinomas, and extrinsically metastatic involvement of the sigmoid colon by rectal carcinoma all correlated well with the pathological findings. The normal structure of the gastric wall was similar to that of the colon. 3D-fast Spoiled Grass (SPGR) sequence has a fairly short scanning time. Thus, the possibility of precise clinical diagnosis by this method was suggested. (author)

  19. The operation technology of realtime image processing system (Datacube)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Lee, Yong Bum; Lee, Nam Ho; Choi, Young Soo; Park, Soon Yong; Park, Jin Seok

    1997-02-01

    In this project, a Sparc VME-based MaxSparc system, running the solaris operating environment, is selected as the dedicated image processing hardware for robot vision applications. In this report, the operation of Datacube maxSparc system, which is high performance realtime image processing hardware, is systematized. And image flow example programs for running MaxSparc system are studied and analyzed. The state-of-the-arts of Datacube system utilizations are studied and analyzed. For the next phase, advanced realtime image processing platform for robot vision application is going to be developed. (author). 19 refs., 71 figs., 11 tabs.

  20. Emerging Endoscopic and Photodynamic Techniques for Bladder Cancer Detection and Surveillance

    Directory of Open Access Journals (Sweden)

    Prashant Patel

    2011-01-01

    Full Text Available This review provides an overview of emerging techniques, namely, photodynamic diagnosis (PDD, narrow band imaging (NBI, Raman spectroscopy, optical coherence tomography, virtual cystoscopy, and endoscopic microscopy for its use in the diagnosis and surveillance of bladder cancer. The technology, clinical evidence and future applications of these approaches are discussed with particular emphasis on PDD and NBI. These approaches show promise to optimise cystoscopy and transurethral resection of bladder tumours.

  1. A hands-free region-of-interest selection interface for solo surgery with a wide-angle endoscope: preclinical proof of concept.

    Science.gov (United States)

    Jung, Kyunghwa; Choi, Hyunseok; Hong, Hanpyo; Adikrishna, Arnold; Jeon, In-Ho; Hong, Jaesung

    2017-02-01

    A hands-free region-of-interest (ROI) selection interface is proposed for solo surgery using a wide-angle endoscope. A wide-angle endoscope provides images with a larger field of view than a conventional endoscope. With an appropriate selection interface for a ROI, surgeons can also obtain a detailed local view as if they moved a conventional endoscope in a specific position and direction. To manipulate the endoscope without releasing the surgical instrument in hand, a mini-camera is attached to the instrument, and the images taken by the attached camera are analyzed. When a surgeon moves the instrument, the instrument orientation is calculated by an image processing. Surgeons can select the ROI with this instrument movement after switching from 'task mode' to 'selection mode.' The accelerated KAZE algorithm is used to track the features of the camera images once the instrument is moved. Both the wide-angle and detailed local views are displayed simultaneously, and a surgeon can move the local view area by moving the mini-camera attached to the surgical instrument. Local view selection for a solo surgery was performed without releasing the instrument. The accuracy of camera pose estimation was not significantly different between camera resolutions, but it was significantly different between background camera images with different numbers of features (P solo surgeries without a camera assistant.

  2. Cloud Engineering Principles and Technology Enablers for Medical Image Processing-as-a-Service

    Science.gov (United States)

    Bao, Shunxing; Plassard, Andrew J.; Landman, Bennett A.; Gokhale, Aniruddha

    2017-01-01

    Traditional in-house, laboratory-based medical imaging studies use hierarchical data structures (e.g., NFS file stores) or databases (e.g., COINS, XNAT) for storage and retrieval. The resulting performance from these approaches is, however, impeded by standard network switches since they can saturate network bandwidth during transfer from storage to processing nodes for even moderate-sized studies. To that end, a cloud-based “medical image processing-as-a-service” offers promise in utilizing the ecosystem of Apache Hadoop, which is a flexible framework providing distributed, scalable, fault tolerant storage and parallel computational modules, and HBase, which is a NoSQL database built atop Hadoop’s distributed file system. Despite this promise, HBase’s load distribution strategy of region split and merge is detrimental to the hierarchical organization of imaging data (e.g., project, subject, session, scan, slice). This paper makes two contributions to address these concerns by describing key cloud engineering principles and technology enhancements we made to the Apache Hadoop ecosystem for medical imaging applications. First, we propose a row-key design for HBase, which is a necessary step that is driven by the hierarchical organization of imaging data. Second, we propose a novel data allocation policy within HBase to strongly enforce collocation of hierarchically related imaging data. The proposed enhancements accelerate data processing by minimizing network usage and localizing processing to machines where the data already exist. Moreover, our approach is amenable to the traditional scan, subject, and project-level analysis procedures, and is compatible with standard command line/scriptable image processing software. Experimental results for an illustrative sample of imaging data reveals that our new HBase policy results in a three-fold time improvement in conversion of classic DICOM to NiFTI file formats when compared with the default HBase region split

  3. Cloud Engineering Principles and Technology Enablers for Medical Image Processing-as-a-Service.

    Science.gov (United States)

    Bao, Shunxing; Plassard, Andrew J; Landman, Bennett A; Gokhale, Aniruddha

    2017-04-01

    Traditional in-house, laboratory-based medical imaging studies use hierarchical data structures (e.g., NFS file stores) or databases (e.g., COINS, XNAT) for storage and retrieval. The resulting performance from these approaches is, however, impeded by standard network switches since they can saturate network bandwidth during transfer from storage to processing nodes for even moderate-sized studies. To that end, a cloud-based "medical image processing-as-a-service" offers promise in utilizing the ecosystem of Apache Hadoop, which is a flexible framework providing distributed, scalable, fault tolerant storage and parallel computational modules, and HBase, which is a NoSQL database built atop Hadoop's distributed file system. Despite this promise, HBase's load distribution strategy of region split and merge is detrimental to the hierarchical organization of imaging data (e.g., project, subject, session, scan, slice). This paper makes two contributions to address these concerns by describing key cloud engineering principles and technology enhancements we made to the Apache Hadoop ecosystem for medical imaging applications. First, we propose a row-key design for HBase, which is a necessary step that is driven by the hierarchical organization of imaging data. Second, we propose a novel data allocation policy within HBase to strongly enforce collocation of hierarchically related imaging data. The proposed enhancements accelerate data processing by minimizing network usage and localizing processing to machines where the data already exist. Moreover, our approach is amenable to the traditional scan, subject, and project-level analysis procedures, and is compatible with standard command line/scriptable image processing software. Experimental results for an illustrative sample of imaging data reveals that our new HBase policy results in a three-fold time improvement in conversion of classic DICOM to NiFTI file formats when compared with the default HBase region split policy

  4. Endoscopic contralateral transmaxillary approach for pterygoid process osteotomy in total maxillectomy: A technical case report.

    Science.gov (United States)

    Hanazawa, Toyoyuki; Yamasaki, Kazuki; Chazono, Hideaki; Okamoto, Yoshitaka

    2018-06-01

    An approach for total maxillectomy with endoscopic transection of the pterygoid process via the contralateral maxillary sinus is described. In total maxillectomy, the resection of the pterygoid process of the sphenoid is a key step for successful resection. However, a conventional craniofacial approach requires extensive incision in the face, elevation of the lateral cheek flap. Even after elevation of the lateral cheek flap, visualization of this region is not good. An endoscopic approach through the contralateral maxillary sinus improved visualization of the pterygoid process, and osteotomy using a diamond-drilling bar was successfully performed. This technique has the potential to widen the indication for total maxillectomy in malignant neoplasms of the maxillary sinus. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. New flexible endoscope for otologic application

    Science.gov (United States)

    Marchan, Mark L.

    1993-07-01

    Endoscopy has become an important procedure in many medical specialties. For the Otologist, however, space limitations within the ear have restricted development of endoscopic procedures. The desire for minimally invasive techniques in Otology has demonstrated itself through the work of numerous physicians who have performed procedures ranging from diagnostic inspection of the middle ear to viewing the interior of the cochlea. To assist in performing such endoscopic procedures, Xomed-Treace has developed a line of flexible fiberoptic endoscopes for use by the Otologist. These scopes combine illumination and imaging fiber bundles within a small diameter unit ranging in size from 0.8 mm to 1.2 mm. The 1.2 mm scope is produced with an angled, rigid stainless steel sheath. The 0.8 mm scope is flexible with the ability to articulate 120 degree(s) in one direction. The fiberscopes have been designed for the Otologist to produce a good resolution image while allowing ease of operation through ergonomics and consideration of the surgical anatomy.

  6. The research on x-ray nondestructive testing and image processing technology of explosive components

    International Nuclear Information System (INIS)

    Shi, C.; Zhai, X.; Liu, Z.; Lin, H.

    2004-01-01

    The explosive components will inevitably produce defects such as impurity, crack and degumming during production and storage, therefore the inside substance of the explosive components must be examined and the findings concerned must be identified and estimated in order to ensure the quality and service life of the explosive components. Firstly, some analyses are conducted on the usual X-ray NDT system theory, and the simulation explosive component is made with some pre-built defects such as debonding, cracks, blow holes, impurities, and non-uniform density. The image testing system most fit for the explosive components is established. Secondly, the ways of X-ray digital image processing are discussed; the obtained images are enhanced and restored through the self-accommodating build-up arithmetic and proper restoring methods. By means of the results of the overall comparison and analysis of the digital image processing technology, it is clearly indicated that it is feasible to use X-ray digital-imaging ways to carry out the NDT of explosive components and identify the inside defects. (author)

  7. Application of phase-contrast cine magnetic resonance imaging in endoscopic aqueductoplasty.

    Science.gov (United States)

    Chen, Guoqiang; Zheng, Jiaping; Xiao, Qing; Liu, Yunsheng

    2013-06-01

    The aim of this study was to evaluate the application of phase-contrast cine magnetic resonance imaging (MRI) in endoscopic aqueductoplasty (EA) for patients with obstructive hydrocephalus. The clinical diagnosis of hydrocephalus caused by aqueduct obstruction in 23 patients was confirmed by phase-contrast cine MRI examination. The patients were treated with EA and MRI was repeated during the follow-up. The cerebrospinal fluid (CSF) flow velocity in the aqueduct was measured to determine whether the aqueduct was obstructed. The results of phase-contrast cine MRI examinations indicated that there was no CSF flow in the aqueduct for all patients prior to surgery. Aqueductoplasty was successfully performed in all patients. The results of phase-contrast cine MRI examinations performed a week after surgery demonstrated an average CSF flow velocity of 4.74±1.77 cm/sec. During the follow-up, intracranial hypertension recurred in two patients in whom CSF flow was not observed in the aqueduct by the phase-contrast cine MRI scan. Aqueduct re-occlusion was revealed by an endoscopic exploration. By measuring the CSF flow velocity, phase-contrast cine MRI accurately identifies aqueduct obstruction. Cine MRI is a nontraumatic, simple and reliable method for determining whether the aqueduct is successfully opened following aqueductoplasty.

  8. Hybrid model based unified scheme for endoscopic Cerenkov and radio-luminescence tomography: Simulation demonstration

    Science.gov (United States)

    Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei

    2018-05-01

    Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.

  9. Essential pre-treatment imaging examinations in patients with endoscopically-diagnosed early gastric cancer

    Directory of Open Access Journals (Sweden)

    Tokunaga Mari

    2010-06-01

    Full Text Available Abstract Background There have been no reports discussing which imaging procedures are truly necessary before treatment of endoscopically-diagnosed early gastric cancer (eEGC. The aim of this pilot study was to show which imaging examinations are essential to select indicated treatment or appropriate strategy in patients with eEGC. Methods In 140 consecutive patients (95 men, 45 women; age, 66.4 +/- 11.3 years [mean +/- standard deviation], range, 33-90 with eEGC which were diagnosed during two years, the pre-treatment results of ultrasonography (US and contrast-enhanced computed tomography (CT of the abdomen, barium enema (BE and chest radiography (CR were retrospectively reviewed. Useful findings that might affect indication or strategy were evaluated. Results US demonstrated useful findings in 13 of 140 patients (9.3%: biliary tract stones (n = 11 and other malignant tumors (n = 2. Only one useful finding was demonstrated on CT (pancreatic intraductal papillary mucinous tumor but not on US (0.7%; 95% confidential interval [CI], 2.1%. BE demonstrated colorectal carcinomas in six patients and polyps in 10 patients, altering treatment strategy (11.4%; 95%CI, 6.1-16.7%. Of these, only two colorectal carcinomas were detected on CT. CR showed three relevant findings (2.1%: pulmonary carcinoma (n = 1 and cardiomegaly (n = 2. Seventy-nine patients (56% were treated surgically and 56 patients were treated by endoscopic intervention. The remaining five patients received no treatment due to various reasons. Conclusions US, BE and CR may be essential as pre-treatment imaging examinations because they occasionally detect findings which affect treatment indication and strategy, although abdominal contrast-enhanced CT rarely provide additional information.

  10. 3D-LSI technology for image sensor

    International Nuclear Information System (INIS)

    Motoyoshi, Makoto; Koyanagi, Mitsumasa

    2009-01-01

    Recently, the development of three-dimensional large-scale integration (3D-LSI) technologies has accelerated and has advanced from the research level or the limited production level to the investigation level, which might lead to mass production. By separating 3D-LSI technology into elementary technologies such as (1) through silicon via (TSV) formation, (2) bump formation, (3) wafer thinning, (4) chip/wafer alignment, and (5) chip/wafer stacking and reconstructing the entire process and structure, many methods to realize 3D-LSI devices can be developed. However, by considering a specific application, the supply chain of base wafers, and the purpose of 3D integration, a few suitable combinations can be identified. In this paper, we focus on the application of 3D-LSI technologies to image sensors. We describe the process and structure of the chip size package (CSP), developed on the basis of current and advanced 3D-LSI technologies, to be used in CMOS image sensors. Using the current LSI technologies, CSPs for 1.3 M, 2 M, and 5 M pixel CMOS image sensors were successfully fabricated without any performance degradation. 3D-LSI devices can be potentially employed in high-performance focal-plane-array image sensors. We propose a high-speed image sensor with an optical fill factor of 100% to be developed using next-generation 3D-LSI technology and fabricated using micro(μ)-bumps and micro(μ)-TSVs.

  11. A survey of passive technology for digital image forensics

    Institute of Scientific and Technical Information of China (English)

    LUO Weiqi; QU Zhenhua; PAN Feng; HUANG Jiwu

    2007-01-01

    Over the past years,digital images have been widely used in the Internet and other applications.Whilst image processing techniques are developing at a rapid speed,tampering with digital images without leaving any obvious traces becomes easier and easier.This may give rise to some problems such as image authentication.A new passive technology for image forensics has evolved quickly during the last few years.Unlike the signature-based or watermark-based methods,the new technology does not need any signature generated or watermark embedded in advance,it assumes that different imaging devices or processing would introduce different inherent patterns into the output images.These underlying patterns are consistent in the original untampered images and would be altered after some kind of manipulations.Thus,they can be used as evidence for image source identification and alteration detection.In this paper,we will discuss this new forensics technology and give an overview of the prior literatures.Some concluding remarks are made about the state of the art and the challenges in this novel technology.

  12. Signal Processing in Medical Ultrasound B-mode Imaging

    International Nuclear Information System (INIS)

    Song, Tai Kyong

    2000-01-01

    Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes 'main stream' digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing

  13. Real-time imaging as an emerging process analytical technology tool for monitoring of fluid bed coating process.

    Science.gov (United States)

    Naidu, Venkata Ramana; Deshpande, Rucha S; Syed, Moinuddin R; Wakte, Pravin S

    2018-07-01

    A direct imaging system (Eyecon TM ) was used as a Process Analytical Technology (PAT) tool to monitor fluid bed coating process. Eyecon TM generated real-time onscreen images, particle size and shape information of two identically manufactured laboratory-scale batches. Eyecon TM has accuracy of measuring the particle size increase of ±1 μm on particles in the size range of 50-3000 μm. Eyecon TM captured data every 2 s during the entire process. The moving average of D90 particle size values recorded by Eyecon TM were calculated for every 30 min to calculate the radial coating thickness of coated particles. After the completion of coating process, the radial coating thickness was found to be 11.3 and 9.11 μm, with a standard deviation of ±0.68 and 1.8 μm for Batch 1 and Batch 2, respectively. The coating thickness was also correlated with percent weight build-up by gel permeation chromatography (GPC) and dissolution. GPC indicated weight build-up of 10.6% and 9.27% for Batch 1 and Batch 2, respectively. In conclusion, weight build-up of 10% can also be correlated with 10 ± 2 μm increase in the coating thickness of pellets, indicating the potential applicability of real-time imaging as an endpoint determination tool for fluid bed coating process.

  14. Processing of medical images

    International Nuclear Information System (INIS)

    Restrepo, A.

    1998-01-01

    Thanks to the innovations in the technology for the processing of medical images, to the high development of better and cheaper computers, and, additionally, to the advances in the systems of communications of medical images, the acquisition, storage and handling of digital images has acquired great importance in all the branches of the medicine. It is sought in this article to introduce some fundamental ideas of prosecution of digital images that include such aspects as their representation, storage, improvement, visualization and understanding

  15. In vivo endoscopic multi-beam optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Standish, Beau A; Mariampillai, Adrian; Munce, Nigel R; Leung, Michael K K; Vitkin, I Alex [Deptartment of Medical Biophysics, University of Toronto, Toronto (Canada); Lee, Kenneth K C; Yang, Victor X D [Ontario Cancer Institute/University Health Network, Toronto (Canada)], E-mail: standish@ee.ryerson.ca

    2010-02-07

    A multichannel optical coherence tomography (multi-beam OCT) system and an in vivo endoscopic imaging probe were developed using a swept-source OCT system. The distal optics were micro-machined to produce a high numerical aperture, multi-focus fibre optic array. This combination resulted in a transverse design resolution of <10 {mu}m full width half maximum (FWHM) throughout the entire imaging range, while also increasing the signal intensity within the focus of the individual channels. The system was used in a pre-clinical rabbit study to acquire in vivo structural images of the colon and ex vivo images of the oesophagus and trachea. A good correlation between the structural multi-beam OCT images and H and E histology was achieved, demonstrating the feasibility of this high-resolution system and its potential for in vivo human endoscopic imaging.

  16. In vivo endoscopic multi-beam optical coherence tomography

    International Nuclear Information System (INIS)

    Standish, Beau A; Mariampillai, Adrian; Munce, Nigel R; Leung, Michael K K; Vitkin, I Alex; Lee, Kenneth K C; Yang, Victor X D

    2010-01-01

    A multichannel optical coherence tomography (multi-beam OCT) system and an in vivo endoscopic imaging probe were developed using a swept-source OCT system. The distal optics were micro-machined to produce a high numerical aperture, multi-focus fibre optic array. This combination resulted in a transverse design resolution of <10 μm full width half maximum (FWHM) throughout the entire imaging range, while also increasing the signal intensity within the focus of the individual channels. The system was used in a pre-clinical rabbit study to acquire in vivo structural images of the colon and ex vivo images of the oesophagus and trachea. A good correlation between the structural multi-beam OCT images and H and E histology was achieved, demonstrating the feasibility of this high-resolution system and its potential for in vivo human endoscopic imaging.

  17. Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection

    Science.gov (United States)

    Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace

    2016-01-01

    Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID

  18. Ultrasound-assisted endoscopic partial plantar fascia release.

    Science.gov (United States)

    Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa

    2013-01-01

    Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.

  19. Feasibility study of novel endoscopic Cerenkov luminescence imaging system in detecting and quantifying gastrointestinal disease: first human results

    International Nuclear Information System (INIS)

    Hu, Hao; Li, Shujun; Yao, Liping; Liang, Jie; Nie, Yongzhan; Wu, Kaichun; Cao, Xin; Lin, Yenan; Liu, Muhan; Liang, Jimin; Chen, Xueli; Kang, Fei; Wang, Jing; Wang, Min

    2015-01-01

    Cerenkov luminescence imaging (CLI) provides potential to use clinical radiotracers for optical imaging. The goal of this study was to present a newly developed endoscopic CLI (ECLI) system and illustrate its feasibility and potential in distinguishing and quantifying cancerous lesions of the GI tract. The ECLI system was established by integrating an electron-multiplying charge-coupled device camera with a flexible fibre endoscope. Phantom experiments and animal studies were conducted to test and illustrate the system in detecting and quantifying the presence of radionuclide in vitro and in vivo. A pilot clinical study was performed to evaluate our system in clinical settings. Phantom and mice experiments demonstrated its ability to acquire both the luminescent and photographic images with high accuracy. Linear quantitative relationships were also obtained when comparing the ECLI radiance with the radiotracer activity (r 2 = 0.9779) and traditional CLI values (r 2 = 0.9025). Imaging of patients revealed the potential of ECLI in the identification and quantification of cancerous tissue from normal, which showed good consistence with the clinical PET examination. The new ECLI system shows good consistence with the clinical PET examination and has great potential for clinical translation and in aiding detection of the GI tract disease. (orig.)

  20. Feasibility study of novel endoscopic Cerenkov luminescence imaging system in detecting and quantifying gastrointestinal disease: first human results

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Hao; Li, Shujun; Yao, Liping; Liang, Jie; Nie, Yongzhan; Wu, Kaichun [Fourth Military Medical University, State Key Laboratory of Cancer Biology, Department of Digestive Diseases, Xijing Hospital, Xi' an (China); Cao, Xin; Lin, Yenan; Liu, Muhan; Liang, Jimin; Chen, Xueli [Xidian University, School of Life Science and Technology, Xi' an (China); Kang, Fei; Wang, Jing [Fourth Military Medical University, Department of Nuclear Medicine, Xijing Hospital, Xi' an (China); Wang, Min [Xi' an Children' s Hospital, Department of Gastroenterology, Xi' an (China)

    2015-06-01

    Cerenkov luminescence imaging (CLI) provides potential to use clinical radiotracers for optical imaging. The goal of this study was to present a newly developed endoscopic CLI (ECLI) system and illustrate its feasibility and potential in distinguishing and quantifying cancerous lesions of the GI tract. The ECLI system was established by integrating an electron-multiplying charge-coupled device camera with a flexible fibre endoscope. Phantom experiments and animal studies were conducted to test and illustrate the system in detecting and quantifying the presence of radionuclide in vitro and in vivo. A pilot clinical study was performed to evaluate our system in clinical settings. Phantom and mice experiments demonstrated its ability to acquire both the luminescent and photographic images with high accuracy. Linear quantitative relationships were also obtained when comparing the ECLI radiance with the radiotracer activity (r{sup 2} = 0.9779) and traditional CLI values (r{sup 2} = 0.9025). Imaging of patients revealed the potential of ECLI in the identification and quantification of cancerous tissue from normal, which showed good consistence with the clinical PET examination. The new ECLI system shows good consistence with the clinical PET examination and has great potential for clinical translation and in aiding detection of the GI tract disease. (orig.)

  1. History, Current Situation, and Future Development of Endoscopic Neurosurgery in China.

    Science.gov (United States)

    Li, Chuzhong; Zhu, Haibo; Zong, Xuyi; Wang, Xinsheng; Gui, Songbai; Zhao, Peng; Zhang, Yazhuo

    2018-02-01

    During the past few decades, Chinese endoscopic neurosurgery has rapidly developed in synchrony with the rest of the world. The aim of this article is to review the development of Chinese endoscopic neurosurgery, including its birth, growth, current situation, and prospects. The history of Chinese endoscopic neurosurgery development can be divided into 3 stages: cognition and initial stage (1964-1995), exploration and maturity stage (1995-2006), and rapid development and promotion stage (2006-present). In the first stage, we mainly began to become aware of endoscopic neurosurgery from the translation and review of literature. In the mid to late 1990s, Chinese neurosurgery pioneers began using neuroendoscopic techniques. In the following decade, many leading neurosurgeons made persistent efforts to push the development of Chinese endoscopic neurosurgery forward, focusing on advocating for and promoting and popularizing neuroendoscopic technology. In the rapid development and promotion stage, many representative national and regional neurosurgical centers became skilled and efficient in the application of neuroendoscopic technology and became new advocates of the technology. The number of cases, level of technology, and treatment effectiveness are gradually nearing international standards. However, future development requires promotion of balanced development to decrease regional disparities, further strengthen international exchanges, follow the latest developments, and constantly innovate for continuous improvement. Following the dramatic efforts of several pioneers, development of Chinese endoscopic neurosurgery has been considerable, and it has become an important component of neurosurgery worldwide. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Creating Panoramic Images for Bladder Fluorescence Endoscopy

    Directory of Open Access Journals (Sweden)

    A. Behrens

    2008-01-01

    Full Text Available The medical diagnostic analysis and therapy of urinary bladder cancer based on endoscopes are state of the art in urological medicine. Due to the limited field of view of endoscopes, the physician can examine only a small part of the whole operating field at once. This constraint makes visual control and navigation difficult, especially in hollow organs. A panoramic image, covering a larger field of view, can overcome this difficulty. Directly motivated by a physician we developed an image mosaicing algorithm for endoscopic bladder fluorescence video sequences. In this paper, we present an approach which is capable of stitching single endoscopic video images to a combined panoramic image. Based on SIFT features we estimate a 2-D homography for each image pair, using an affine model and an iterative model-fitting algorithm. We then apply the stitching process and perform a mutual linear interpolation. Our panoramic image results show a correct stitching and lead to a better overview and understanding of the operation field. 

  3. METHODOLOGICAL FOUNDATIONS OF FORMING FUTURE TECHNOLOGY TEACHERS’ PROFESSIONAL IMAGE IN THE EDUCATIONAL PROCESS OF HIGHER EDUCATIONAL INSTITUTION

    Directory of Open Access Journals (Sweden)

    Volodymyr Bondarenko

    2017-04-01

    Full Text Available The article singles out modern scientific and methodological approaches to forming future technology teachers’ professional image in the educational process at the university. The basic position and acmeological and axiological approaches are analyzed. They are the basis for the system of the future technology teachers’ professional image forming and they will ensure its effectiveness. The personal “terminal” values of vocational and professional development and cultural identity of a future technology teacher are classified. The internal “terminal” values (the components of the image “I” as a person and professional and external “terminal” values (the components of the image of external characteristics are determined. From axiological position all target reference points of the future technology teachers’ vocational and professional and cultural identity as terminal values are classified into three groups: 1 values – aims of the competence level; 2 values – aims of the basic cultural level (this includes professional image values; 3 values – aims of the acmeological level. The second group is determined as the key values, these are the aims, the core of which is the category of “technology teacher’s basic professional culture”. Acmeological approach allows to identify a set of methodologically educated future technology teacher’s competences, which should be the new components of his image of "I" as a professional at the highest level of his/her development: the ability to self-actualization and self-realization in professional pedagogical and social activities; the ability to realize the highest meaning of the technology teacher’s pedagogical activity with the phenomenological reduction tools; readiness for the continuous humanization of technology lessons; ability to professional pedagogical reflection at the conceptual level; polymodality of pedagogical thinking, the ability to master artistic and

  4. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    Science.gov (United States)

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  5. Near-infrared dental imaging using scanning fiber endoscope

    Science.gov (United States)

    Zhou, Yaxuan; Lee, Robert; Sadr, Alireza; Seibel, Eric J.

    2018-02-01

    Near-infrared (NIR) wavelength range of 1300-1500nm has the potential to outperform or augment other dental imaging modalities such as fluorescence imaging, owing to its lower scattering coefficient in enamel and trans- parency on stains and non-cariogenic plaque. However, cameras in this wavelength range are bulky and expensive, which lead to difficulties for in-vivo use and commercialization. Thus, we have proposed a new imaging device combining the scanning fiber endoscopy (SFE) and NIR imaging technology. The NIR SFE system has the advantage of miniature size (1.6 mm), flexible shaft, video frame rate (7Hz) and expandable wide field-of-view (60 degrees). Eleven extracted human teeth with or without occlusal caries were scanned by micro-computed X-ray tomography (micro-CT) to obtain 3D micro-CT images, which serve as the standard for comparison. NIR images in reflection mode were then taken on all the occlusal surfaces, using 1310nm super luminescent diode and 1460nm laser diode respectively. Qualitative comparison was performed between near-infrared im- ages and micro-CT images. Enamel demineralization in NIR appeared as areas of increased reflectivity, and distinguished from non-carious staining at the base of occlusal fissures or developmental defects on cusps. This preliminary work presented proof for practicability of combining NIR imaging technology with SFE for reliable and noninvasive dental imaging with miniaturization and low cost.

  6. Endoscopic ultrasound for the characterization and staging of rectal cancer. Current state of the method. Technological advances and perspectives.

    Science.gov (United States)

    Gersak, Mariana M; Badea, Radu; Graur, Florin; Hajja, Nadim Al; Furcea, Luminita; Dudea, Sorin M

    2015-06-01

    Endoscopic ultrasound is the most accurate type of examination for the assessment of rectal tumors. Over the years, the method has advanced from gray-scale examination to intravenous contrast media administration and to different types of elastography. The multimodal approach of tumors (transrectal, transvaginal) is adapted to each case. 3D ultrasound is useful for spatial representation and precise measurement of tumor formations, using CT/MR image reconstruction; color elastography is useful for tumor characterization and staging; endoscopic ultrasound using intravenous contrast agents can help study the amount of contrast agent targeted at the level of the tumor formations and contrast wash-in/wash-out time, based on the curves displayed on the device. The transvaginal approach often allows better visualization of the tumor than the transrectal approach. Performing the procedure with the rectal ampulla distended with contrast agent may be seen as an optimization of the examination methodology. All these aspects are additional methods for gray-scale endoscopic ultrasound, capable of increasing diagnostic accuracy. This paper aims at reviewing the progress of transrectal and transvaginal ultrasound, generically called endoscopic ultrasound, for rectal tumor diagnosis and staging, with emphasis on the current state of the method and its development trends.

  7. Transsphenoidal Approach in Endoscopic Endonasal Surgery for Skull Base Lesions: What Radiologists and Surgeons Need to Know.

    Science.gov (United States)

    García-Garrigós, Elena; Arenas-Jiménez, Juan José; Monjas-Cánovas, Irene; Abarca-Olivas, Javier; Cortés-Vela, Jesús Julián; De La Hoz-Rosa, Javier; Guirau-Rubio, Maria Dolores

    2015-01-01

    In the last 2 decades, endoscopic endonasal transsphenoidal surgery has become the most popular choice of neurosurgeons and otolaryngologists to treat lesions of the skull base, with minimal invasiveness, lower incidence of complications, and lower morbidity and mortality rates compared with traditional approaches. The transsphenoidal route is the surgical approach of choice for most sellar tumors because of the relationship of the sphenoid bone to the nasal cavity below and the pituitary gland above. More recently, extended approaches have expanded the indications for transsphenoidal surgery by using different corridors leading to specific target areas, from the crista galli to the spinomedullary junction. Computer-assisted surgery is an evolving technology that allows real-time anatomic navigation during endoscopic surgery by linking preoperative triplanar radiologic images and intraoperative endoscopic views, thus helping the surgeon avoid damage to vital structures. Preoperative computed tomography is the preferred modality to show bone landmarks and vascular structures. Radiologists play an important role in surgical planning by reporting extension of sphenoid pneumatization, recesses and septations of the sinus, and other relevant anatomic variants. Radiologists should understand the relationships of the sphenoid bone and skull base structures, anatomic variants, and image-guided neuronavigation techniques to prevent surgical complications and allow effective treatment of skull base lesions with the endoscopic endonasal transsphenoidal approach. ©RSNA, 2015.

  8. Research on fast Fourier transforms algorithm of huge remote sensing image technology with GPU and partitioning technology.

    Science.gov (United States)

    Yang, Xue; Li, Xue-You; Li, Jia-Guo; Ma, Jun; Zhang, Li; Yang, Jan; Du, Quan-Ye

    2014-02-01

    Fast Fourier transforms (FFT) is a basic approach to remote sensing image processing. With the improvement of capacity of remote sensing image capture with the features of hyperspectrum, high spatial resolution and high temporal resolution, how to use FFT technology to efficiently process huge remote sensing image becomes the critical step and research hot spot of current image processing technology. FFT algorithm, one of the basic algorithms of image processing, can be used for stripe noise removal, image compression, image registration, etc. in processing remote sensing image. CUFFT function library is the FFT algorithm library based on CPU and FFTW. FFTW is a FFT algorithm developed based on CPU in PC platform, and is currently the fastest CPU based FFT algorithm function library. However there is a common problem that once the available memory or memory is less than the capacity of image, there will be out of memory or memory overflow when using the above two methods to realize image FFT arithmetic. To address this problem, a CPU and partitioning technology based Huge Remote Fast Fourier Transform (HRFFT) algorithm is proposed in this paper. By improving the FFT algorithm in CUFFT function library, the problem of out of memory and memory overflow is solved. Moreover, this method is proved rational by experiment combined with the CCD image of HJ-1A satellite. When applied to practical image processing, it improves effect of the image processing, speeds up the processing, which saves the time of computation and achieves sound result.

  9. Digital image processing mathematical and computational methods

    CERN Document Server

    Blackledge, J M

    2005-01-01

    This authoritative text (the second part of a complete MSc course) provides mathematical methods required to describe images, image formation and different imaging systems, coupled with the principle techniques used for processing digital images. It is based on a course for postgraduates reading physics, electronic engineering, telecommunications engineering, information technology and computer science. This book relates the methods of processing and interpreting digital images to the 'physics' of imaging systems. Case studies reinforce the methods discussed, with examples of current research

  10. Development of image-guided operation system having integrated information of the patient for procedure of endoscopic surgery of digestive tracts

    International Nuclear Information System (INIS)

    Hattori, Asaki; Suzuki, Naoki; Tanoue, Kazuo; Ieiri, Satoshi; Konishi, Kozo; Tomikawa, Morimasa; Kenmotsu, Hajime; Hashizume, Makoto

    2010-01-01

    This study reports the development of patient's integrated information-displaying system at image-guided, robotic peroral endoscopic operation of digestive tracts as well as the actual operative field for the operator not to look aside. The peroral endoscope has, at its top, a magnetic position sensor and 2 robotic manipulative forceps at right and left side to navigate the surgery through following 3 windows of superimposing display: the inner peritoneal 3D structure of the real operative field reconstructed from preoperative CT and MR images by volume rendering, presentation of the robot top tip in the structure above and in the preoperative CT or MR image as an ordinary navigation. Furthermore, the robot has a function to measure softness of its grabbing tissue which is displayed in the corresponding right and left superimposing windows, and signs like the real-time blood pressure and heart rate are also given in another window. All of the patient's integrated information-displaying can be handled at will during the operation. Improvement of user interface and of navigation display is further to be conducted. (T.T.)

  11. Endoscopic Lung Volume Reduction : An Expert Panel Recommendation - Update 2017

    NARCIS (Netherlands)

    Herth, Felix J. F.; Slebos, Dirk-Jan; Criner, Gerard J.; Shah, Pallav L.

    2017-01-01

    Interest in endoscopic lung volume reduction (ELVR) technologies for emphysema is consistently growing. In the last couple of months, several endoscopic options (e.g., endo-or intrabronchial valves, coil implants, and thermal vapor ablation) that have been evaluated in randomized controlled trials

  12. Endoscopic management of peripancreatic fluid collections.

    Science.gov (United States)

    Goyal, Jatinder; Ramesh, Jayapal

    2015-07-01

    Peripancreatic fluid collections are a well-known complication of pancreatitis and can vary from fluid-filled collections to entirely necrotic collections. Although most of the fluid-filled pseudocysts tend to resolve spontaneously with conservative management, intervention is necessary in symptomatic patients. Open surgery has been the traditional treatment modality of choice though endoscopic, laparoscopic and transcutaneous techniques offer alternative drainage approaches. During the last decade, improvement in endoscopic ultrasound technology has enabled real-time access and drainage of fluid collections that were previously not amenable to blind transmural drainage. This has initiated a trend towards use of this modality for treatment of pseudocysts. In this review, we have summarised the existing evidence for endoscopic drainage of peripancreatic fluid collections from published studies.

  13. An algorithm for improving the quality of structural images of turbid media in endoscopic optical coherence tomography

    Science.gov (United States)

    Potlov, A. Yu.; Frolov, S. V.; Proskurin, S. G.

    2018-04-01

    High-quality OCT structural images reconstruction algorithm for endoscopic optical coherence tomography of biological tissue is described. The key features of the presented algorithm are: (1) raster scanning and averaging of adjacent Ascans and pixels; (2) speckle level minimization. The described algorithm can be used in the gastroenterology, urology, gynecology, otorhinolaryngology for mucous membranes and skin diagnostics in vivo and in situ.

  14. Taking NOTES: translumenal flexible endoscopy and endoscopic surgery.

    Science.gov (United States)

    Willingham, Field F; Brugge, William R

    2007-09-01

    To review the current state of natural orifice surgery and examine the concerns, challenges, and opportunities presented by translumenal research. Translumenal endoscopic procedures have been the focus of extensive research. Researchers have reported natural orifice translumenal endoscopic surgery in a swine model in several areas involving the abdominal cavity. Diagnostic procedures have included endoscopic peritoneoscopy, liver biopsy, lymphadenectomy, and abdominal exploration. Several gynecologic procedures including tubal ligation, oophorectomy, and partial hysterectomy have been demonstrated using current commercial endoscopes. Gastrointestinal surgical procedures, including gastrojejunostomy, cholecystectomy, splenectomy, and distal pancreatectomy have been performed successfully via transgastric and/or transcolonic approaches. There have been no studies of natural orifice translumenal endoscopic surgery procedures published in humans. While fundamental questions about the emerging technology have not been scrutinized, limitations of the large animal model will pose a challenge to the development of large randomized trials. While natural orifice translumenal endoscopic surgery may represent a paradigm shift and may offer significant benefits to patients, rigorous testing of the techniques is lacking and current data have been drawn from case series.

  15. Three-dimensional image signals: processing methods

    Science.gov (United States)

    Schiopu, Paul; Manea, Adrian; Craciun, Anca-Ileana; Craciun, Alexandru

    2010-11-01

    Over the years extensive studies have been carried out to apply coherent optics methods in real-time processing, communications and transmission image. This is especially true when a large amount of information needs to be processed, e.g., in high-resolution imaging. The recent progress in data-processing networks and communication systems has considerably increased the capacity of information exchange. We describe the results of literature investigation research of processing methods for the signals of the three-dimensional images. All commercially available 3D technologies today are based on stereoscopic viewing. 3D technology was once the exclusive domain of skilled computer-graphics developers with high-end machines and software. The images capture from the advanced 3D digital camera can be displayed onto screen of the 3D digital viewer with/ without special glasses. For this is needed considerable processing power and memory to create and render the complex mix of colors, textures, and virtual lighting and perspective necessary to make figures appear three-dimensional. Also, using a standard digital camera and a technique called phase-shift interferometry we can capture "digital holograms." These are holograms that can be stored on computer and transmitted over conventional networks. We present some research methods to process "digital holograms" for the Internet transmission and results.

  16. Anatomic structural study of cerebellopontine angle via endoscope

    Institute of Scientific and Technical Information of China (English)

    XIA Yin; LI Xi-ping; HAN De-min; ZHENG Jun; LONG Hai-shan; SHI Jin-feng

    2007-01-01

    Background Minimally invasive surgery in skull base relying on searching for possible anatomic basis for endoscopic technology is controversial. The objective of this study was to observe the spatial relationships between main blood vessels and nerves in the cerebellopontine angle area and provide anatomic basis for lateral and posterior skull base minimally invasive surgery via endoscopic retrosigmoid keyhole approach.Methods This study was conducted on thirty dried adult skulls to measure the spatial relationships among the surface bony marks of posterior cranial fossa, and to locate the most appropriate drilling area for retrosigmoid keyhole approach.In addition, we used 10 formaldehyde-fixed adult cadaver specimens for simulating endoscopic retrosigmoid approach to determine the visible scope.Results The midpoint between the mastoid tip and the asterion was the best drilling point for retrosigmoid approach. A hole centered on this point with the 2.0 cm in diameter was suitable for exposing the related structures in the cerebellopontine angle. Retrosigmoid keyhole approach can decrease the pressure on the cerebellum and expose the related structures effectively which include facial nerve, vestibulocochlear nerve, trigeminal nerve, glossopharyngeal nerve, vagus nerve, accessory nerve, hypoglossal nerve, anterior inferior cerebellar artery, posterior inferior cerebellar artery and labyrinthine artery, etc.Conclusions Exact location on endoscope retrosigmoid approach can avoid dragging cerebellum during the minimally invasive surgery. The application of retrosigmoid keyhole approach will extend the application of endoscopic technology.

  17. Endoscopic mode for three-dimensional CT display of normal and pathologic laryngeal structures

    International Nuclear Information System (INIS)

    Sanuki, Tetsuji; Hyodo, Masamitsu; Yumoto, Eiji; Yasuhara, Yoshifumi; Ochi, Takashi

    1997-01-01

    The recent development of helical (spiral) computed tomography allows collection of volumetric data to obtain high quality three-dimensional (3D) reconstructed images. The authors applied the 3D CT endoscopic imaging technique to asses normal and pathologic laryngeal structures. The latter included trauma, vocal fold atrophy, cancer of the larynx and recurrent nerve palsy. This technique was able to show normal laryngeal structures and characteristic findings of each pathology. The 3D CT endoscopic images can be rotated around any axis, allowing optimal depiction of pathologic lesion. The use of 3D CT endoscopic technique provides the display of the location and extent of pathology and affords accurate therapeutic planning. (author)

  18. Teaching Image-Processing Concepts in Junior High School: Boys' and Girls' Achievements and Attitudes towards Technology

    Science.gov (United States)

    Barak, Moshe; Asad, Khaled

    2012-01-01

    Background: This research focused on the development, implementation and evaluation of a course on image-processing principles aimed at middle-school students. Purpose: The overarching purpose of the study was that of integrating the learning of subjects in science, technology, engineering and mathematics (STEM), and linking the learning of these…

  19. Combining endoscopes with PIV and digital holography for the study of vessel model mechanics

    International Nuclear Information System (INIS)

    Arévalo, Laura; Palero, Virginia; Andrés, Nieves; Arroyo, M P; Lobera, Julia

    2015-01-01

    In this work traditional fluid and solid mechanics measurement techniques have been combined with endoscopes for the study of blood vessel models’ mechanical properties. Endoscopes have been used as the imaging part of a high-speed PIV system to obtain the velocity field in a vessel model immersed in a container with a refractive index-matching liquid. In this way, we take advantage of the fact that the endoscope tip can be immersed in liquid. Endoscopes have also been used as the imaging and illuminating part of a digital holographic set-up for wall deformation measurement. The novelty of this work is that only one endoscope was used for illuminating and observing the vessel model, using the endoscope’s own illuminating system as the illumination source. The performance of endoscopes in different vessel models has been tested. The results of flow velocity and wall deformation in the different blood vessel models are presented. (paper)

  20. Medical imaging technology reviews and computational applications

    CERN Document Server

    Dewi, Dyah

    2015-01-01

    This book presents the latest research findings and reviews in the field of medical imaging technology, covering ultrasound diagnostics approaches for detecting osteoarthritis, breast carcinoma and cardiovascular conditions, image guided biopsy and segmentation techniques for detecting lung cancer, image fusion, and simulating fluid flows for cardiovascular applications. It offers a useful guide for students, lecturers and professional researchers in the fields of biomedical engineering and image processing.

  1. Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.

    Science.gov (United States)

    Ye, L; Zhou, X; Li, J; Jin, J

    2011-09-01

    Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.

  2. Full optical model of micro-endoscope with optical coherence microscopy, multiphoton microscopy and visible capabilities

    Science.gov (United States)

    Vega, David; Kiekens, Kelli C.; Syson, Nikolas C.; Romano, Gabriella; Baker, Tressa; Barton, Jennifer K.

    2018-02-01

    While Optical Coherence Microscopy (OCM), Multiphoton Microscopy (MPM), and narrowband imaging are powerful imaging techniques that can be used to detect cancer, each imaging technique has limitations when used by itself. Combining them into an endoscope to work in synergy can help achieve high sensitivity and specificity for diagnosis at the point of care. Such complex endoscopes have an elevated risk of failure, and performing proper modelling ensures functionality and minimizes risk. We present full 2D and 3D models of a multimodality optical micro-endoscope to provide real-time detection of carcinomas, called a salpingoscope. The models evaluate the endoscope illumination and light collection capabilities of various modalities. The design features two optical paths with different numerical apertures (NA) through a single lens system with a scanning optical fiber. The dual path is achieved using dichroic coatings embedded in a triplet. A high NA optical path is designed to perform OCM and MPM while a low NA optical path is designed for the visible spectrum to navigate the endoscope to areas of interest and narrowband imaging. Different tests such as the reflectance profile of homogeneous epithelial tissue were performed to adjust the models properly. Light collection models for the different modalities were created and tested for efficiency. While it is challenging to evaluate the efficiency of multimodality endoscopes, the models ensure that the system is design for the expected light collection levels to provide detectable signal to work for the intended imaging.

  3. High-quality endoscope reprocessing decreases endoscope contamination.

    Science.gov (United States)

    Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D

    2018-02-24

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Linear Algebra and Image Processing

    Science.gov (United States)

    Allali, Mohamed

    2010-01-01

    We use the computing technology digital image processing (DIP) to enhance the teaching of linear algebra so as to make the course more visual and interesting. Certainly, this visual approach by using technology to link linear algebra to DIP is interesting and unexpected to both students as well as many faculty. (Contains 2 tables and 11 figures.)

  5. Endoscopic retrograde cholangiopancreatography and endoscopic ...

    African Journals Online (AJOL)

    An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis was suspected on ...

  6. [Tracheotomy-endoscop for dilatational percutaneous tracheotomy (TED)].

    Science.gov (United States)

    Klemm, Eckart

    2006-09-01

    While surgical tracheotomies are currently performed using state-of-the-art operative techniques, percutaneous dilatational tracheostomy (PDT) is in a rapidly evolving state with regard to its technology and the number of techniques available. This has resulted in a range of new complications that are difficult to quantify on a scientific basis, given the fact that more than half of the patients who are tracheotomized in intensive care units die from their underlying disease. The new Tracheotomy Endoscope (TED) is designed to help prevent serious complications in dilatational tracheotomies and facilitate their management. The endoscope has been specifically adapted to meet the require-ments of percutaneous dilatational tracheotomies. It is fully compatible with all current techniques of PDT. The method is easy to learn. The percutaneous dilatational tracheotomy with the Tracheotomy Endoscope is a seven-step procedure: Advantages of the Tracheotomy Endoscope: Injuries to the posterior tracheal wall ar impossible (tracheoesophageal fistulas, pneumothorax). Minor bleeding sites on the tracheal mucosa can be controlled with a specially curved suction-coagulation tube introudeced through the Tracheotomy Endoscope. In cases with heavy bleeding and a risk of aspiration, the rigid indwelling Tracheotomy Endoscope provides a secure route for reintubating the patient with a cuffed endotracheal tube. It also allows for rapid conversion to an open surgical procedure if necessary. All the parts are easy to clean and are autoclavable. This type of endoscopically guided PDT creates an optimal link between the specialties of intensive care medicine and otorhinolaryngology. The Tracheotomy Endoscope (TED) increases the standard of safety in PDT.

  7. Employing image processing techniques for cancer detection using microarray images.

    Science.gov (United States)

    Dehghan Khalilabad, Nastaran; Hassanpour, Hamid

    2017-02-01

    Microarray technology is a powerful genomic tool for simultaneously studying and analyzing the behavior of thousands of genes. The analysis of images obtained from this technology plays a critical role in the detection and treatment of diseases. The aim of the current study is to develop an automated system for analyzing data from microarray images in order to detect cancerous cases. The proposed system consists of three main phases, namely image processing, data mining, and the detection of the disease. The image processing phase performs operations such as refining image rotation, gridding (locating genes) and extracting raw data from images the data mining includes normalizing the extracted data and selecting the more effective genes. Finally, via the extracted data, cancerous cell is recognized. To evaluate the performance of the proposed system, microarray database is employed which includes Breast cancer, Myeloid Leukemia and Lymphomas from the Stanford Microarray Database. The results indicate that the proposed system is able to identify the type of cancer from the data set with an accuracy of 95.45%, 94.11%, and 100%, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Virtual endoscopy post-processing of helical CT data sets

    International Nuclear Information System (INIS)

    Dessl, A.; Giacomuzzi, S.M.; Springer, P.; Stoeger, A.; Pototschnig, C.; Voelklein, C.; Schreder, S.G.; Jaschke, W.

    1997-01-01

    Purpose: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n=2), the tracheobronchial system (n=3), the nasal sinuses (n=2), the colon (n=2), and the common carotid artery (n=1). Software developed specifically for virtual endoscopy ('Navigator') was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. Results: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Thorugh use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. Conclusions: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware. (orig.) [de

  9. MEMS-based non-rotatory circumferential scanning optical probe for endoscopic optical coherence tomography

    Science.gov (United States)

    Xu, Yingshun; Singh, Janak; Siang, Teo Hui; Ramakrishna, Kotlanka; Premchandran, C. S.; Sheng, Chen Wei; Kuan, Chuah Tong; Chen, Nanguang; Olivo, Malini C.; Sheppard, Colin J. R.

    2007-07-01

    In this paper, we present a non-rotatory circumferential scanning optical probe integrated with a MEMS scanner for in vivo endoscopic optical coherence tomography (OCT). OCT is an emerging optical imaging technique that allows high resolution cross-sectional imaging of tissue microstructure. To extend its usage to endoscopic applications, a miniaturized optical probe based on Microelectromechanical Systems (MEMS) fabrication techniques is currently desired. A 3D electrothermally actuated micromirror realized using micromachining single crystal silicon (SCS) process highlights its very large angular deflection, about 45 degree, with low driving voltage for safety consideration. The micromirror is integrated with a GRIN lens into a waterproof package which is compatible with requirements for minimally invasive endoscopic procedures. To implement circumferential scanning substantially for diagnosis on certain pathological conditions, such as Barret's esophagus, the micromirror is mounted on 90 degree to optical axis of GRIN lens. 4 Bimorph actuators that are connected to the mirror on one end via supporting beams and springs are selected in this micromirror design. When actuators of the micromirror are driven by 4 channels of sinusoidal waveforms with 90 degree phase differences, beam focused by a GRIN is redirected out of the endoscope by 45 degree tilting mirror plate and achieve circumferential scanning pattern. This novel driving method making full use of very large angular deflection capability of our micromirror is totally different from previously developed or developing micromotor-like rotatory MEMS device for circumferential scanning.

  10. Automatic tissue image segmentation based on image processing and deep learning

    Science.gov (United States)

    Kong, Zhenglun; Luo, Junyi; Xu, Shengpu; Li, Ting

    2018-02-01

    Image segmentation plays an important role in multimodality imaging, especially in fusion structural images offered by CT, MRI with functional images collected by optical technologies or other novel imaging technologies. Plus, image segmentation also provides detailed structure description for quantitative visualization of treating light distribution in the human body when incorporated with 3D light transport simulation method. Here we used image enhancement, operators, and morphometry methods to extract the accurate contours of different tissues such as skull, cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) on 5 fMRI head image datasets. Then we utilized convolutional neural network to realize automatic segmentation of images in a deep learning way. We also introduced parallel computing. Such approaches greatly reduced the processing time compared to manual and semi-automatic segmentation and is of great importance in improving speed and accuracy as more and more samples being learned. Our results can be used as a criteria when diagnosing diseases such as cerebral atrophy, which is caused by pathological changes in gray matter or white matter. We demonstrated the great potential of such image processing and deep leaning combined automatic tissue image segmentation in personalized medicine, especially in monitoring, and treatments.

  11. Quantum imaging technologies

    International Nuclear Information System (INIS)

    Malik, M.; Boyd, R.W.

    2014-01-01

    Over the past three decades, quantum mechanics has allowed the development of technologies that provide unconditionally secure communication. In parallel, the quantum nature of the transverse electromagnetic field has spawned the field of quantum imaging that encompasses technologies such as quantum lithography, quantum ghost imaging, and high-dimensional quantum key distribution (QKD). The emergence of such quantum technologies also highlights the need for the development of accurate and efficient methods of measuring and characterizing the elusive quantum state itself. In this paper, we describe new technologies that use the quantum properties of light for security. The first of these is a technique that extends the principles behind QKD to the field of imaging and optical ranging. By applying the polarization-based BB84 protocol to individual photons in an active imaging system, we obtained images that are secure against any interceptresend jamming attacks. The second technology presented in this article is based on an extension of quantum ghost imaging, a technique that uses position-momentum entangled photons to create an image of an object without directly obtaining any spatial information from it. We used a holographic filtering technique to build a quantum ghost image identification system that uses a few pairs of photons to identify an object from a set of known objects. The third technology addressed in this document is a high-dimensional QKD system that uses orbital-angular-momentum (OAM) modes of light for encoding. Moving to a high-dimensional state space in QKD allows one to impress more information on each photon, as well as introduce higher levels of security. We discuss the development of two OAM-QKD protocols based on the BB84 and Ekert protocols of QKD. The fourth and final technology presented in this article is a relatively new technique called direct measurement that uses sequential weak and strong measurements to characterize a quantum state

  12. Improvements in SPECT technology for cerebral imaging

    International Nuclear Information System (INIS)

    Esser, P.D.

    1985-01-01

    Advancement in three major areas of SPECT (single photon emission computed tomography) technology have resulted in improved image quality for cerebral studies. In the first area, single-crystal camera electronics, extensive use of microprocessors, custom digital circuitry, an data bus architecture have allowed precise external control of all gantry motions and improved signal processing. The new digital circuitry permits energy, uniformity, and linearity corrections to be an integral part of the processing electronics. Calibration of these correlations is controlled by algorithms stored in the camera's memory. The second area of improved SPECT technology is camera collimation and related imaging techniques. In this area, system resolution has been improved without loss of sensitivity by decreasing the air gap between patient and collimator surface. Since cerebral studies characteristically image high-contrast regions less than 1 cm in size, image quality has been improved by increasing collimator resolution even at the expense of sensitivity. Increased resolution also improved image contrast for studies using 123 I-labeled pharmaceuticals with 3% to 4% 124 I contamination. 65 references

  13. Comparison of microscopic and endoscopic view of the internal acoustic meatus: A cadaveric study.

    Science.gov (United States)

    Montibeller, Guilherme Ramina; Hendrix, Philipp; Fries, Fabian N; Becker, Kurt W; Oertel, Joachim

    2018-04-01

    The endoscope is thought to provide an improved exposure of the internal acoustic meatus after retrosigmoid craniotomy for microsurgical resection of intrameatal tumors. The aim of this study is to quantify the differences in internal acoustic meatus (IAM) exposure comparing microscopic and endoscopic visualization. A retrosigmoid approach was performed on 5 cadaver heads. A millimeter gauge was introduced into the internal acoustic meatus, and examinations with a surgical microscope and 0°, 30° and 70° rigid endoscopes were performed. The extent of IAM depth visualized with the microscope and the different angled endoscopes were analyzed. The microscopic view allowed an average IAM depth visualization of 2.8 mm. The endoscope allowed an improved exposure of IAM in all cases. The 0°, 30° and 70° endoscopes permitted an exposure that was respectively 96% (5.5 mm), 139% (6.7 mm) and 200% (8.4 mm) more lateral than the microscopic view. Angled optics, however, provided an image distortion, specifically the 70° endoscope. The endoscope provides a superior visualization of the IAM compared to the microscope when using a retrosigmoid approach. The 30° endoscope represented an ideal compromise of superior visualization with marginal image distortion. Additional implementation of the endoscope into microsurgery of intrameatal tumors likely facilitates complete tumor removal and might spare facial and vestibulocochlear function. Clin. Anat. 31:398-403, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  14. New endoscope shaft for endoscopic transsphenoidal pituitary surgery.

    NARCIS (Netherlands)

    Lindert, E.J. van; Grotenhuis, J.A.

    2005-01-01

    OBJECTIVE: To describe a new endoscope shaft developed for suction-aspiration during endoscopic transsphenoidal pituitary surgery. METHODS: A custom-made shaft for a Wolf endoscope (Richard Wolf GmbH, Knittlingen, Germany) was developed with a height of 10 mm and a width of 5 mm, allowing an

  15. Multispectral image enhancement processing for microsat-borne imager

    Science.gov (United States)

    Sun, Jianying; Tan, Zheng; Lv, Qunbo; Pei, Linlin

    2017-10-01

    With the rapid development of remote sensing imaging technology, the micro satellite, one kind of tiny spacecraft, appears during the past few years. A good many studies contribute to dwarfing satellites for imaging purpose. Generally speaking, micro satellites weigh less than 100 kilograms, even less than 50 kilograms, which are slightly larger or smaller than the common miniature refrigerators. However, the optical system design is hard to be perfect due to the satellite room and weight limitation. In most cases, the unprocessed data captured by the imager on the microsatellite cannot meet the application need. Spatial resolution is the key problem. As for remote sensing applications, the higher spatial resolution of images we gain, the wider fields we can apply them. Consequently, how to utilize super resolution (SR) and image fusion to enhance the quality of imagery deserves studying. Our team, the Key Laboratory of Computational Optical Imaging Technology, Academy Opto-Electronics, is devoted to designing high-performance microsat-borne imagers and high-efficiency image processing algorithms. This paper addresses a multispectral image enhancement framework for space-borne imagery, jointing the pan-sharpening and super resolution techniques to deal with the spatial resolution shortcoming of microsatellites. We test the remote sensing images acquired by CX6-02 satellite and give the SR performance. The experiments illustrate the proposed approach provides high-quality images.

  16. Resident simulation training in endoscopic endonasal surgery utilizing haptic feedback technology.

    Science.gov (United States)

    Thawani, Jayesh P; Ramayya, Ashwin G; Abdullah, Kalil G; Hudgins, Eric; Vaughan, Kerry; Piazza, Matthew; Madsen, Peter J; Buch, Vivek; Sean Grady, M

    2016-12-01

    Simulated practice may improve resident performance in endoscopic endonasal surgery. Using the NeuroTouch haptic simulation platform, we evaluated resident performance and assessed the effect of simulation training on performance in the operating room. First- (N=3) and second- (N=3) year residents were assessed using six measures of proficiency. Using a visual analog scale, the senior author scored subjects. After the first session, subjects with lower scores were provided with simulation training. A second simulation served as a task-learning control. Residents were evaluated in the operating room over six months by the senior author-who was blinded to the trained/untrained identities-using the same parameters. A nonparametric bootstrap testing method was used for the analysis (Matlab v. 2014a). Simulation training was associated with an increase in performance scores in the operating room averaged over all measures (p=0.0045). This is the first study to evaluate the training utility of an endoscopic endonasal surgical task using a virtual reality haptic simulator. The data suggest that haptic simulation training in endoscopic neurosurgery may contribute to improvements in operative performance. Limitations include a small number of subjects and adjudication bias-although the trained/untrained identity of subjects was blinded. Further study using the proposed methods may better describe the relationship between simulated training and operative performance in endoscopic Neurosurgery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Advanced virtual endoscopy for endoscopic transsphenoidal pituitary surgery.

    Science.gov (United States)

    Wolfsberger, Stefan; Neubauer, André; Bühler, Katja; Wegenkittl, Rainer; Czech, Thomas; Gentzsch, Stephan; Böcher-Schwarz, Hans-Gerd; Knosp, Engelbert

    2006-11-01

    Virtual endoscopy (vE) is the navigation of a camera through a virtual anatomical space that is computationally reconstructed from radiological image data. Inside this three-dimensional space, arbitrary movements and adaptations of viewing parameters are possible. Thereby, vE can be used for noninvasive diagnostic purposes and for simulation of surgical tasks. This article describes the development of an advanced system of vE for endoscopic transsphenoidal pituitary surgery and its application to teaching, training, and in the routine clinical setting. The vE system was applied to a series of 35 patients with pituitary pathology (32 adenomas, three Rathke's cleft cysts) operated endoscopically via the transsphenoidal route at the Department of Neurosurgery of the Medical University Vienna between 2004 and 2006. The virtual endoscopic images correlated well with the intraoperative view. For the transsphenoidal approach, vE improved intraoperative orientation by depicting anatomical landmarks and variations. For planning a safe and tailored opening of the sellar floor, transparent visualization of the pituitary adenoma and the normal gland in relation to the internal carotid arteries was useful. According to our experience, vE can be a valuable tool for endoscopic transsphenoidal pituitary surgery for training purposes and preoperative planning. For the novice, it can act as a simulator for endoscopic anatomy and for training surgical tasks. For the experienced pituitary surgeon, vE can depict the individual patient's anatomy, and may, therefore, improve intraoperative orientation. By prospectively visualizing unpredictable anatomical variations, vE may increase the safety of this surgical procedure.

  18. Optical transfection using an endoscope-like system.

    Science.gov (United States)

    Ma, Nan; Gunn-Moore, Frank; Dholakia, Kishan

    2011-02-01

    Optical transfection is a powerful method for targeted delivery of therapeutic agents to biological cells. A tightly focused pulsed laser beam may transiently change the permeability of a cell membrane to facilitate the delivery of foreign genetic material into cells. We report the first realization of an endoscope-like integrated system for optical transfection. An imaging fiber (coherent optical fiber bundle) with ∼ 6000 cores (pixels) embedded in a fiber cladding of ∼ 300 μm in diameter, produces an image circle (area) of ∼ 270 μm diam. This imaging fiber, with an ordered axicon lens array chemically etched at its exit face, is used for the delivery of a femtosecond laser to the cell membrane for optical transfection along with subcellular resolution imaging. A microcapillary-based microfluidic system for localized drug delivery was also combined in this miniature, flexible system. Using this novel system, a plasmid transfection efficiency up to ∼ 72% was obtained for CHO-K1 cells. This endoscope-like system opens a range of exciting applications, in particular, in the targeted in vivo optical microsurgery area.

  19. Quaternion Fourier transforms for signal and image processing

    CERN Document Server

    Ell, Todd A; Sangwine, Stephen J

    2014-01-01

    Based on updates to signal and image processing technology made in the last two decades, this text examines the most recent research results pertaining to Quaternion Fourier Transforms. QFT is a central component of processing color images and complex valued signals. The book's attention to mathematical concepts, imaging applications, and Matlab compatibility render it an irreplaceable resource for students, scientists, researchers, and engineers.

  20. Usefulness of combined percutaneous-endoscopic rendezvous techniques after failed therapeutic endoscopic retrograde cholangiography in the era of endoscopic ultrasound guided rendezvous.

    Science.gov (United States)

    Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Kim, Soon Sun; Lim, Sun Gyo; Won, Je Hwan

    2017-12-01

    The rendezvous approach is a salvage technique after failure of endoscopic retrograde cholangiography (ERC). In certain circumstances, percutaneous-endoscopic rendezvous (PE-RV) is preferred, and endoscopic ultrasound-guided rendezvous (EUS-RV) is difficult to perform. We aimed to evaluate PE-RV outcomes, describe the PE-RV techniques, and identify potential indications for PE-RV over EUS-RV.Retrospective analysis was conducted of a prospectively designed ERC database between January 2005 and December 2016 at a tertiary referral center including cases where PE-RV was used as a salvage procedure after ERC failure.During the study period, PE-RV was performed in 42 cases after failed therapeutic ERC; 15 had a surgically altered enteric anatomy. The technical success rate of PE-RV was 92.9% (39/42), with a therapeutic success rate of 88.1% (37/42). Potential indications for PE-RV over EUS-RV were identified in 23 cases, and either PE-RV or EUS-RV could have effectively been used in 19 cases. Endoscopic bile duct access was successfully achieved with PE-RV in 39 cases with accessible biliary orifice using one of PE-RV cannulation techniques (classic, n = 11; parallel, n = 19; and adjunctive maneuvers, n = 9).PE-RV uses a unique technology and has clinical indications that distinguish it from EUS-RV. Therefore, PE-RV can still be considered a useful salvage technique for the treatment of biliary obstruction after ERC failure.

  1. Endoscopic Endonasal Approach for a Suprasellar Craniopharyngioma.

    Science.gov (United States)

    Zenonos, Georgios A; Snyderman, Carl H; Gardner, Paul A

    2018-04-01

    Objectives  The current video presents the nuances of an endoscopic endonasal approach to a suprasellar craniopharyngioma. Design  The video analyzes the presentation, preoperative workup and imaging, surgical steps and technical nuances of the surgery, the clinical outcome, and follow-up imaging. Setting  The patient was treated by a skull base team consisting of a neurosurgeon and an ENT surgeon, at a teaching academic institution. Participants  The case refers to a 67-year-old man who presented with vision loss and headaches, and was found to have a suprasellar mass, with imaging characteristics consistent with a craniopharyngioma. Main Outcome Measures  The main outcome measures consistent of the reversal of the patient symptoms (vision loss and headaches), the recurrence-free survival based on imaging, as well as the absence of any complications. Results  The patient's vision improved after the surgery; at his last follow-up there was no evidence of recurrence on imaging. Conclusions  The endoscopic endonasal approach is safe and effective in treating suprasellar craniopharyngiomas. The link to the video can be found at: https://youtu.be/p1VXbwnAWCo .

  2. Clinical endoscopic management and outcome of post-endoscopic sphincterotomy bleeding.

    Directory of Open Access Journals (Sweden)

    Wei-Chen Lin

    Full Text Available Post-endoscopic sphincterotomy bleeding is a common complication of biliary sphincterotomy, and the incidence varies from 1% to 48%. It can be challenging to localize the bleeder or to administer various interventions through a side-viewing endoscope. This study aimed to evaluate the risk factors of post-endoscopic sphincterotomy bleeding and the outcome of endoscopic intervention therapies. We retrospectively reviewed the records of 513 patients who underwent biliary sphincterotomy in Mackay Memorial Hospital between 2011 and 2016. The blood biochemistry, comorbidities, indication for sphincterotomy, severity of bleeding, endoscopic features of bleeder, and type of endoscopic therapy were analyzed. Post-endoscopic sphincterotomy bleeding occurred in 65 (12.6% patients. Forty-five patients had immediate bleeding and 20 patients had delayed bleeding. The multivariate analysis of risk factors associated with post-endoscopic sphincterotomy bleeding were liver cirrhosis (P = 0.029, end-stage renal disease (P = 0.038, previous antiplatelet drug use (P<0.001, and duodenal ulcer (P = 0.023. The complications of pancreatitis and cholangitis were higher in the bleeding group, with statistical significance. Delayed bleeding occurred within 1 to 7 days (mean, 2.5 days, and 60% (12/20 of the patients received endoscopic evaluation. In the delayed bleeding group, the successful hemostasis rate was 71.4% (5/7, and 65% (13/20 of the patients had ceased bleeding without endoscopic hemostasis therapy. Comparison of different therapeutic modalities showed that cholangitis was higher in patients who received epinephrine spray (P = 0.042 and pancreatitis was higher in patients who received epinephrine injection and electrocoagulation (P = 0.041 and P = 0.039 respectively. Clinically, post-endoscopic sphincterotomy bleeding and further endoscopic hemostasis therapy increase the complication rate of pancreatitis and cholangitis. Realizing the effectiveness of each

  3. "Seeing is believing": perspectives of applying imaging technology in discovery toxicology.

    Science.gov (United States)

    Xu, Jinghai James; Dunn, Margaret Condon; Smith, Arthur Russell

    2009-11-01

    Efficiency and accuracy in addressing drug safety issues proactively are critical in minimizing late-stage drug attritions. Discovery toxicology has become a specialty subdivision of toxicology seeking to effectively provide early predictions and safety assessment in the drug discovery process. Among the many technologies utilized to select safer compounds for further development, in vitro imaging technology is one of the best characterized and validated to provide translatable biomarkers towards clinically-relevant outcomes of drug safety. By carefully applying imaging technologies in genetic, hepatic, and cardiac toxicology, and integrating them with the rest of the drug discovery processes, it was possible to demonstrate significant impact of imaging technology on drug research and development and substantial returns on investment.

  4. Plant phenomics: an overview of image acquisition technologies and image data analysis algorithms.

    Science.gov (United States)

    Perez-Sanz, Fernando; Navarro, Pedro J; Egea-Cortines, Marcos

    2017-11-01

    The study of phenomes or phenomics has been a central part of biology. The field of automatic phenotype acquisition technologies based on images has seen an important advance in the last years. As with other high-throughput technologies, it addresses a common set of problems, including data acquisition and analysis. In this review, we give an overview of the main systems developed to acquire images. We give an in-depth analysis of image processing with its major issues and the algorithms that are being used or emerging as useful to obtain data out of images in an automatic fashion. © The Author 2017. Published by Oxford University Press.

  5. Towards an ultra-thin medical endoscope: multimode fibre as a wide-field image transferring medium

    Science.gov (United States)

    Duriš, Miroslav; Bradu, Adrian; Podoleanu, Adrian; Hughes, Michael

    2018-03-01

    Multimode optical fibres are attractive for biomedical and industrial applications such as endoscopes because of the small cross section and imaging resolution they can provide in comparison to widely-used fibre bundles. However, the image is randomly scrambled by propagation through a multimode fibre. Even though the scrambling is unpredictable, it is deterministic, and therefore the scrambling can be reversed. To unscramble the image, we treat the multimode fibre as a linear, disordered scattering medium. To calibrate, we scan a focused beam of coherent light over thousands of different beam positions at the distal end and record complex fields at the proximal end of the fibre. This way, the inputoutput response of the system is determined, which then allows computational reconstruction of reflection-mode images. However, there remains the problem of illuminating the tissue via the fibre while avoiding back reflections from the proximal face. To avoid this drawback, we provide here the first preliminary confirmation that an image can be transferred through a 2x2 fibre coupler, with the sample at its distal port interrogated in reflection. Light is injected into one port for illumination and then collected from a second port for imaging.

  6. Processing Of Binary Images

    Science.gov (United States)

    Hou, H. S.

    1985-07-01

    An overview of the recent progress in the area of digital processing of binary images in the context of document processing is presented here. The topics covered include input scan, adaptive thresholding, halftoning, scaling and resolution conversion, data compression, character recognition, electronic mail, digital typography, and output scan. Emphasis has been placed on illustrating the basic principles rather than descriptions of a particular system. Recent technology advances and research in this field are also mentioned.

  7. Design and validation of a near-infrared fluorescence endoscope for detection of early esophageal malignancy using a targeted imaging probe

    Science.gov (United States)

    Waterhouse, Dale J.; Joseph, James; Neves, Andre A.; di Pietro, Massimiliano; Brindle, Kevin M.; Fitzgerald, Rebecca C.; Bohndiek, Sarah E.

    2016-03-01

    Barrett's esophagus is a condition that predisposes patients to esophageal cancer. Early detection of cancer in these patients can be curative, but is confounded by a lack of contrast in white light endoscopy (WLE). Application of fluorescently-labeled lectins to the esophagus during endoscopy can more accurately delineate dysplasia emerging within Barrett's than WLE1, but strong tissue autofluorescence has limited sensitivity and dynamic range of this approach. To overcome this challenge, we synthesized a near-infrared (NIR) fluorescent lectin and have constructed a clinically translatable endoscope for simultaneous WLE and NIR imaging. An imaging fiber bundle, shielded from patient contact using a disposable catheter, relays collected light into an optical path that splits the WL reflectance and NIR emission onto two cameras for simultaneous video-rate recording. The captured images are co-registered and the honeycomb artifact arising from the fiber bundle is removed using interpolation between image points derived from individual fibers. A minimum detectable concentration of 110 nM was determined using a dilution series of IRDye800CW-lectin in black well plates. We have demonstrated the ability to use our endoscope to distinguish between different tissue types in ex vivo mouse stomachs. Future work using human ex vivo tissue specimens will determine safe illumination limits and sensitivity for dysplasia and adenocarcinoma in Barrett's esophagus, prior to commencing clinical trials.

  8. Automated processing of X-ray images in medicine

    International Nuclear Information System (INIS)

    Babij, Ya.S.; B'yalyuk, Ya.O.; Yanovich, I.A.; Lysenko, A.V.

    1991-01-01

    Theoretical and practical achievements in application of computing technology means for processing of X-ray images in medicine were generalized. The scheme of the main directions and tasks of processing of X-ray images was given and analyzed. The principal problems appeared in automated processing of X-ray images were distinguished. It is shown that for interpretation of X-ray images it is expedient to introduce a notion of relative operating characteristic (ROC) of a roentgenologist. Every point on ROC curve determines the individual criteria of roentgenologist to put a positive diagnosis for definite situation

  9. Fluorescence-Raman Dual Modal Endoscopic System for Multiplexed Molecular Diagnostics

    Science.gov (United States)

    Jeong, Sinyoung; Kim, Yong-Il; Kang, Homan; Kim, Gunsung; Cha, Myeong Geun; Chang, Hyejin; Jung, Kyung Oh; Kim, Young-Hwa; Jun, Bong-Hyun; Hwang, Do Won; Lee, Yun-Sang; Youn, Hyewon; Lee, Yoon-Sik; Kang, Keon Wook; Lee, Dong Soo; Jeong, Dae Hong

    2015-03-01

    Optical endoscopic imaging, which was recently equipped with bioluminescence, fluorescence, and Raman scattering, allows minimally invasive real-time detection of pathologies on the surface of hollow organs. To characterize pathologic lesions in a multiplexed way, we developed a dual modal fluorescence-Raman endomicroscopic system (FRES), which used fluorescence and surface-enhanced Raman scattering nanoprobes (F-SERS dots). Real-time, in vivo, and multiple target detection of a specific cancer was successful, based on the fast imaging capability of fluorescence signals and the multiplex capability of simultaneously detected SERS signals using an optical fiber bundle for intraoperative endoscopic system. Human epidermal growth factor receptor 2 (HER2) and epidermal growth factor receptor (EGFR) on the breast cancer xenografts in a mouse orthotopic model were successfully detected in a multiplexed way, illustrating the potential of FRES as a molecular diagnostic instrument that enables real-time tumor characterization of receptors during routine endoscopic procedures.

  10. Spectrally enhanced imaging of occlusal surfaces and artificial shallow enamel erosions with a scanning fiber endoscope

    Science.gov (United States)

    Zhang, Liang; Nelson, Leonard Y.; Seibel, Eric J.

    2012-07-01

    An ultrathin scanning fiber endoscope, originally developed for cancer diagnosis, was used to image dental occlusal surfaces as well as shallow artificially induced enamel erosions from human extracted teeth (n=40). Enhanced image resolution of occlusal surfaces was obtained using a short-wavelength 405-nm illumination laser. In addition, artificial erosions of varying depths were also imaged with 405-, 404-, 532-, and 635-nm illumination lasers. Laser-induced autofluorescence images of the teeth using 405-nm illumination were also obtained. Contrast between sound and eroded enamel was quantitatively computed for each imaging modality. For shallow erosions, the image contrast with respect to sound enamel was greatest for the 405-nm reflected image. It was also determined that the increased contrast was in large part due to volume scattering with a smaller component from surface scattering. Furthermore, images obtained with a shallow penetration depth illumination laser (405 nm) provided the greatest detail of surface enamel topography since the reflected light does not contain contributions from light reflected from greater depths within the enamel tissue. Multilayered Monte Carlo simulations were also performed to confirm the experimental results.

  11. Endoscopic Management of a Primary Duodenal Carcinoid Tumor

    Directory of Open Access Journals (Sweden)

    Albin Abraham

    2012-03-01

    Full Text Available Carcinoids are rare, slow-growing tumors originating from a variety of different neuroendocrine cell types. They are identified histologically by their affinity for silver salts and by positive reactions to neuroendocrine markers such as neuron-specific enolase, synaptophysin and chromogranin. They can present with various clinical symptoms and are difficult to diagnose. We present the case of a 43-year-old woman who was referred for evaluation of anemia. Upper endoscopy showed a duodenal bulb mass around 1 cm in size. Histopathological and immunohistochemistry staining were consistent with the diagnosis of a carcinoid tumor. Further imaging and endoscopic studies showed no other synchronous carcinoid lesions. Endoscopic ultrasound (EUS revealed a 1 cm lesion confined to the mucosa and no local lymphadenopathy. Successful endoscopic mucosal resection of the mass was performed. Follow-up surveillance 6 months later with EUS and Octreoscan revealed no new lesions suggestive of recurrence. No consensus guidelines exist for the endoscopic management of duodenal carcinoid tumors. However, endoscopic resection is safe and preferred for tumors measuring 1 cm or less with no evidence of invasion of the muscularis layer.

  12. High-performance method of morphological medical image processing

    Directory of Open Access Journals (Sweden)

    Ryabykh M. S.

    2016-07-01

    Full Text Available the article shows the implementation of grayscale morphology vHGW algorithm for selection borders in the medical image. Image processing is executed using OpenMP and NVIDIA CUDA technology for images with different resolution and different size of the structuring element.

  13. EDITORIAL: Molecular Imaging Technology

    Science.gov (United States)

    Asai, Keisuke; Okamoto, Koji

    2006-06-01

    'Molecular Imaging Technology' focuses on image-based techniques using nanoscale molecules as sensor probes to measure spatial variations of various species (molecular oxygen, singlet oxygen, carbon dioxide, nitric monoxide, etc) and physical properties (pressure, temperature, skin friction, velocity, mechanical stress, etc). This special feature, starting on page 1237, contains selected papers from The International Workshop on Molecular Imaging for Interdisciplinary Research, sponsored by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) in Japan, which was held at the Sendai Mediatheque, Sendai, Japan, on 8 9 November 2004. The workshop was held as a sequel to the MOSAIC International Workshop that was held in Tokyo in 2003, to summarize the outcome of the 'MOSAIC Project', a five-year interdisciplinary project supported by Techno-Infrastructure Program, the Special Coordination Fund for Promotion of Science Technology to develop molecular sensor technology for aero-thermodynamic research. The workshop focused on molecular imaging technology and its applications to interdisciplinary research areas. More than 110 people attended this workshop from various research fields such as aerospace engineering, automotive engineering, radiotechnology, fluid dynamics, bio-science/engineering and medical engineering. The purpose of this workshop is to stimulate intermixing of these interdisciplinary fields for further development of molecular sensor and imaging technology. It is our pleasure to publish the seven papers selected from our workshop as a special feature in Measurement and Science Technology. We will be happy if this issue inspires people to explore the future direction of molecular imaging technology for interdisciplinary research.

  14. UCXp camera imaging principle and key technologies of data post-processing

    International Nuclear Information System (INIS)

    Yuan, Fangyan; Li, Guoqing; Zuo, Zhengli; Liu, Jianmin; Wu, Liang; Yu, Xiaoping; Zhao, Haitao

    2014-01-01

    The large format digital aerial camera product UCXp was introduced into the Chinese market in 2008, the image consists of 17310 columns and 11310 rows with a pixel size of 6 mm. The UCXp camera has many advantages compared with the same generation camera, with multiple lenses exposed almost at the same time and no oblique lens. The camera has a complex imaging process whose principle will be detailed in this paper. On the other hand, the UCXp image post-processing method, including data pre-processing and orthophoto production, will be emphasized in this article. Based on the data of new Beichuan County, this paper will describe the data processing and effects

  15. UCXp camera imaging principle and key technologies of data post-processing

    Science.gov (United States)

    Yuan, Fangyan; Li, Guoqing; Zuo, Zhengli; Liu, Jianmin; Wu, Liang; Yu, Xiaoping; Zhao, Haitao

    2014-03-01

    The large format digital aerial camera product UCXp was introduced into the Chinese market in 2008, the image consists of 17310 columns and 11310 rows with a pixel size of 6 mm. The UCXp camera has many advantages compared with the same generation camera, with multiple lenses exposed almost at the same time and no oblique lens. The camera has a complex imaging process whose principle will be detailed in this paper. On the other hand, the UCXp image post-processing method, including data pre-processing and orthophoto production, will be emphasized in this article. Based on the data of new Beichuan County, this paper will describe the data processing and effects.

  16. The Impact Of Optical Storage Technology On Image Processing Systems

    Science.gov (United States)

    Garges, Daniel T.; Durbin, Gerald T.

    1984-09-01

    The recent announcement of commercially available high density optical storage devices will have a profound impact on the information processing industry. Just as the initial introduction of random access storage created entirely new processing strategies, optical technology will allow dramatic changes in the storage, retrieval, and dissemination of engineering drawings and other pictorial or text-based documents. Storage Technology Corporation has assumed a leading role in this arena with the introduction of the 7600 Optical Storage Subsystem, and the formation of StorageTek Integrated Systems, a subsidiary chartered to incorporate this new technology into deliverable total systems. This paper explores the impact of optical storage technology from the perspective of a leading-edge manufacturer and integrator.

  17. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...

  18. Image processing system design for microcantilever-based optical readout infrared arrays

    Science.gov (United States)

    Tong, Qiang; Dong, Liquan; Zhao, Yuejin; Gong, Cheng; Liu, Xiaohua; Yu, Xiaomei; Yang, Lei; Liu, Weiyu

    2012-12-01

    Compared with the traditional infrared imaging technology, the new type of optical-readout uncooled infrared imaging technology based on MEMS has many advantages, such as low cost, small size, producing simple. In addition, the theory proves that the technology's high thermal detection sensitivity. So it has a very broad application prospects in the field of high performance infrared detection. The paper mainly focuses on an image capturing and processing system in the new type of optical-readout uncooled infrared imaging technology based on MEMS. The image capturing and processing system consists of software and hardware. We build our image processing core hardware platform based on TI's high performance DSP chip which is the TMS320DM642, and then design our image capturing board based on the MT9P031. MT9P031 is Micron's company high frame rate, low power consumption CMOS chip. Last we use Intel's company network transceiver devices-LXT971A to design the network output board. The software system is built on the real-time operating system DSP/BIOS. We design our video capture driver program based on TI's class-mini driver and network output program based on the NDK kit for image capturing and processing and transmitting. The experiment shows that the system has the advantages of high capturing resolution and fast processing speed. The speed of the network transmission is up to 100Mbps.

  19. Image exploitation and dissemination prototype of distributed image processing

    International Nuclear Information System (INIS)

    Batool, N.; Huqqani, A.A.; Mahmood, A.

    2003-05-01

    Image processing applications requirements can be best met by using the distributed environment. This report presents to draw inferences by utilizing the existed LAN resources under the distributed computing environment using Java and web technology for extensive processing to make it truly system independent. Although the environment has been tested using image processing applications, its design and architecture is truly general and modular so that it can be used for other applications as well, which require distributed processing. Images originating from server are fed to the workers along with the desired operations to be performed on them. The Server distributes the task among the Workers who carry out the required operations and send back the results. This application has been implemented using the Remote Method Invocation (RMl) feature of Java. Java RMI allows an object running in one Java Virtual Machine (JVM) to invoke methods on another JVM thus providing remote communication between programs written in the Java programming language. RMI can therefore be used to develop distributed applications [1]. We undertook this project to gain a better understanding of distributed systems concepts and its uses for resource hungry jobs. The image processing application is developed under this environment

  20. [Inspecting the cochlear scala tympanic with flexible and semi-flexible micro-endoscope].

    Science.gov (United States)

    Zhang, Daoxcing; Zhang, Yankun

    2006-02-01

    Flexible and semi-flexible micro-endoscopes were used in cochlear scala tympani inspection , to explore their application in inner ear examination. Fifteen profound hearing loss patients preparing for cochlear implant were included in this study. During the operation, micro-endoscopy was performed after opening the cochlear scala tympani. And 1 mm diameter semi-flexible micro-endoscope could go as deep as 9 mm into the cochlear scala tympani, while 0. 5 mm diameter flexible micro-endoscope could go as deep as 25 mm. The inspecting results were compared with video recording. Using 0.5 mm flexible micro-endoscope, we canould check cochlear scala tympani with depth range of 15-25 mm, but the video imaging was not clear enough to examine the microstructure in the cochlear. With 1 mm diameter semi-flexible micro-endoscope, we could reach 9 mm deep into the cochlear. During the examination, we found 3 cases with calcification deposit in osseous spiral lamina, l case with granulation tissue in the lateral wall of scala tympani, no abnormal findings in the other 11 cases. Inspecting the cochlear scala tympani with 0.5 mm flexible micro-endoscope, even though we can reach the second circuit of the cochlear, it is difficult to find the pathology in the cochlear because of the poor video imaging. With 1 mm semi-flexible micro-endoscope, we can identify the microstructure of the cochlear clearly and find the pathologic changes, but the inserting depth was limited to 9 mm with limitation to examine the whole cochlear.

  1. PC image processing

    International Nuclear Information System (INIS)

    Hwa, Mok Jin Il; Am, Ha Jeng Ung

    1995-04-01

    This book starts summary of digital image processing and personal computer, and classification of personal computer image processing system, digital image processing, development of personal computer and image processing, image processing system, basic method of image processing such as color image processing and video processing, software and interface, computer graphics, video image and video processing application cases on image processing like satellite image processing, color transformation of image processing in high speed and portrait work system.

  2. REVIEW OF MATHEMATICAL METHODS AND ALGORITHMS OF MEDICAL IMAGE PROCESSING ON THE EXAMPLE OF TECHNOLOGY OF MEDICAL IMAGE PROCESSING FROM WOLFRAM MATHEMATICA

    Directory of Open Access Journals (Sweden)

    О. E. Prokopchenko

    2015-09-01

    Full Text Available The article analyzes the basic methods and algorithms of mathematical processing of medical images as objects of computer mathematics. The presented methods and computer algorithms of mathematics relevant and may find application in the field of medical imaging - automated processing of images; as a tool for measurement and determination the optical parameters; identification and formation of medical images database. Methods and computer algorithms presented in the article & based on Wolfram Mathematica are also relevant to the problem of modern medical education. As an example of Wolfram Mathematica may be considered appropriate demonstration, such as recognition of special radiographs and morphological imaging. These methods are used to improve the diagnostic significance and value of medical (clinical research and can serve as an educational interactive demonstration. Implementation submitted individual methods and algorithms of computer Wolfram Mathematics contributes, in general, the optimization process of practical processing and presentation of medical images.

  3. Endoscopic anatomy of the orbital floor and maxillary sinus.

    Science.gov (United States)

    Moore, Corey C; Bromwich, Matthew; Roth, Kathy; Matic, Damir B

    2008-01-01

    Endoscopic repair of orbital blow-out fractures could become a predictable and efficient treatment alternative to traditional methods. However, maxillary sinus endoscopy provides a complex and disorienting view of the orbital floor. To be a useful and consistent technique for providing access to the orbital floor, specific knowledge of maxillary endoscopic anatomy is required. The purpose of the study was to provide an anatomic description of the orbital floor via the endoscopic approach. Objectives include defining consistent landmarks for use in endoscopic repair of orbital floor fractures. Using 0- and 30-degree rigid endoscopes, 6 fresh cadavers (12 maxillary sinuses) were examined via a standard Caldwell-Luc approach. Computed tomographic scans, plastic molds, and digital images were used to compare observable averages within bony anatomy. Potential bony landmarks were correlated with soft-tissue anatomy in fresh specimens. The maxillary ostium, orbital floor, and lateral ethmoid air cells were visualized, and their structures were described. Observations were made in relation to the anatomy of the orbital floor and maxillary sinus, including fracture pattern and force transmission pathways. An "orbitomaxillary" sinus bony thickening was identified and described for the first time. This study provides the basis for further refinement of surgical technique and opens the door for future clinical trials using endoscopic repair.

  4. Endoscopic Ultrasound Elastography: Current Clinical Use in Pancreas.

    Science.gov (United States)

    Mondal, Utpal; Henkes, Nichole; Patel, Sandeep; Rosenkranz, Laura

    2016-08-01

    Elastography is a newer technique for the assessment of tissue elasticity using ultrasound. Cancerous tissue is known to be stiffer (hence, less elastic) than corresponding healthy tissue, and as a result, could be identified in an elasticity-based imaging. Ultrasound elastography has been used in the breast, thyroid, and cervix to differentiate malignant from benign neoplasms and to guide or avoid unnecessary biopsies. In the liver, elastography has enabled a noninvasive and reliable estimate of fibrosis. Endoscopic ultrasound has become a robust diagnostic and therapeutic tool for the management of pancreatic diseases. The addition of elastography to endoscopic ultrasound enabled further characterization of pancreas lesions, and several European and Asian studies have reported encouraging results. The current clinical role of endoscopic ultrasound elastography in the management of pancreas disorders and related literature are reviewed.

  5. Earth Observation Services (Image Processing Software)

    Science.gov (United States)

    1992-01-01

    San Diego State University and Environmental Systems Research Institute, with other agencies, have applied satellite imaging and image processing techniques to geographic information systems (GIS) updating. The resulting images display land use and are used by a regional planning agency for applications like mapping vegetation distribution and preserving wildlife habitats. The EOCAP program provides government co-funding to encourage private investment in, and to broaden the use of NASA-developed technology for analyzing information about Earth and ocean resources.

  6. Real time video processing software for the analysis of endoscopic guided-biopsies

    International Nuclear Information System (INIS)

    Ordoñez, C; Bouchet, A; Pastore, J; Blotta, E

    2011-01-01

    The severity in Barrett esophagus disease is, undoubtedly, the possibility of its malignization. To make an early diagnosis in order to avoid possible complications, it is absolutely necessary collect biopsies to make a histological analysis. This should be done under endoscopic control to avoid mucus areas that may co-exist within the columnar epithelial, which could lead to a false diagnosis. This paper presents a video processing software in real-time in order to delineate and enhance areas of interest to facilitate the work of the expert.

  7. Potential of Near-Infrared Chemical Imaging as Process Analytical Technology Tool for Continuous Freeze-Drying.

    Science.gov (United States)

    Brouckaert, Davinia; De Meyer, Laurens; Vanbillemont, Brecht; Van Bockstal, Pieter-Jan; Lammens, Joris; Mortier, Séverine; Corver, Jos; Vervaet, Chris; Nopens, Ingmar; De Beer, Thomas

    2018-04-03

    Near-infrared chemical imaging (NIR-CI) is an emerging tool for process monitoring because it combines the chemical selectivity of vibrational spectroscopy with spatial information. Whereas traditional near-infrared spectroscopy is an attractive technique for water content determination and solid-state investigation of lyophilized products, chemical imaging opens up possibilities for assessing the homogeneity of these critical quality attributes (CQAs) throughout the entire product. In this contribution, we aim to evaluate NIR-CI as a process analytical technology (PAT) tool for at-line inspection of continuously freeze-dried pharmaceutical unit doses based on spin freezing. The chemical images of freeze-dried mannitol samples were resolved via multivariate curve resolution, allowing us to visualize the distribution of mannitol solid forms throughout the entire cake. Second, a mannitol-sucrose formulation was lyophilized with variable drying times for inducing changes in water content. Analyzing the corresponding chemical images via principal component analysis, vial-to-vial variations as well as within-vial inhomogeneity in water content could be detected. Furthermore, a partial least-squares regression model was constructed for quantifying the water content in each pixel of the chemical images. It was hence concluded that NIR-CI is inherently a most promising PAT tool for continuously monitoring freeze-dried samples. Although some practicalities are still to be solved, this analytical technique could be applied in-line for CQA evaluation and for detecting the drying end point.

  8. Turbine imaging technology assessment

    Energy Technology Data Exchange (ETDEWEB)

    Moursund, R. A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Carlson, T. J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-12-01

    The goal of this project was to identify and evaluate imaging technologies for observing juvenile fish within a Kaplan turbine, and specifically that would enable scientists to determine mechanisms of fish injury within an operating turbine unit. This report documents the opportunities and constraints for observing juvenile fish at specific locations during turbine passage. These observations were used to make modifications to dam structures and operations to improve conditions for fish passage while maintaining or improving hydropower production. The physical and hydraulic environment that fish experience as they pass through the hydroelectric plants were studied and the regions with the greatest potential for injury were defined. Biological response data were also studied to determine the probable types of injuries sustained in the turbine intake and what types of injuries are detectable with imaging technologies. The study grouped injury-causing mechanisms into two categories: fluid (pressure/cavitation, shear, turbulence) and mechanical (strike/collision, grinding/pinching, scraping). The physical constraints of the environment, together with the likely types of injuries to fish, provided the parameters needed for a rigorous imaging technology evaluation. Types of technology evaluated included both tracking and imaging systems using acoustic technologies (such as sonar and acoustic tags) and optic technologies (such as pulsed-laser videography, which is high-speed videography using a laser as the flash). Criteria for determining image data quality such as frame rate, target detectability, and resolution were used to quantify the minimum requirements of an imaging sensor.

  9. Imaging technologies to study the composition of live pigs: A review

    Energy Technology Data Exchange (ETDEWEB)

    Carabús, A.; Gispert, M.; Font-i-Furnols, M.

    2016-11-01

    Image techniques are increasingly being applied to livestock animals. This paper overviews recent advances in image processing analysis for live pigs, including ultrasound, visual image analysis by monitoring, dual-energy X-ray absorptiometry, magnetic resonance imaging and computed tomography. The methodology for live pigs evaluation, advantages and disadvantages of different devices, the variables and measurements analysed, the predictions obtained using these measurements and their accuracy are discussed in the present paper. Utilities of these technologies for livestock purposes are also reviewed. Computed tomography and magnetic resonance imaging yield useful results for the estimation of the amount of fat and lean mass either in live pigs or in carcasses. Ultrasound is not sufficiently accurate when high precision in estimating pig body composition is necessary but can provide useful information in agriculture to classify pigs for breeding purposes or before slaughter. Improvements in factors, such as the speed of scanning, cost and image accuracy and processing, would advance the application of image processing technologies in livestock animals. (Author)

  10. REVIEW OF MATHEMATICAL METHODS AND ALGORITHMS OF MEDICAL IMAGE PROCESSING ON THE EXAMPLE OF TECHNOLOGY OF MEDICAL IMAGE PROCESSING FROM WOLFRAM MATHEMATICS

    Directory of Open Access Journals (Sweden)

    O. Ye. Prokopchenko

    2015-10-01

    Full Text Available The article analyzes the basic methods and algorithms of mathematical processing of medical images as objects of computer mathematics. The presented methods and computer algorithms of mathematics relevant and may find application in the field of medical imaging - automated processing of images; as a tool for measurement and determination the optical parameters; identification and formation of medical images database. Methods and computer algorithms presented in the article and based on Wolfram Mathematica are also relevant to the problem of modern medical education. As an example of Wolfram Mathematics may be considered appropriate demonstration, such as recognition of special radiographs and morphological imaging. These methods are used to improve  the diagnostic significance and value of medical (clinical research and can serve as an educational interactive demonstration. Implementation submitted individual methods and algorithms of computer Wolfram Mathematics contributes, in general, the optimization process of practical processing and presentation of medical images.

  11. New method for detection of gastric cancer by hyperspectral imaging: a pilot study

    Science.gov (United States)

    Kiyotoki, Shu; Nishikawa, Jun; Okamoto, Takeshi; Hamabe, Kouichi; Saito, Mari; Goto, Atsushi; Fujita, Yusuke; Hamamoto, Yoshihiko; Takeuchi, Yusuke; Satori, Shin; Sakaida, Isao

    2013-02-01

    We developed a new, easy, and objective method to detect gastric cancer using hyperspectral imaging (HSI) technology combining spectroscopy and imaging A total of 16 gastroduodenal tumors removed by endoscopic resection or surgery from 14 patients at Yamaguchi University Hospital, Japan, were recorded using a hyperspectral camera (HSC) equipped with HSI technology Corrected spectral reflectance was obtained from 10 samples of normal mucosa and 10 samples of tumors for each case The 16 cases were divided into eight training cases (160 training samples) and eight test cases (160 test samples) We established a diagnostic algorithm with training samples and evaluated it with test samples Diagnostic capability of the algorithm for each tumor was validated, and enhancement of tumors by image processing using the HSC was evaluated The diagnostic algorithm used the 726-nm wavelength, with a cutoff point established from training samples The sensitivity, specificity, and accuracy rates of the algorithm's diagnostic capability in the test samples were 78.8% (63/80), 92.5% (74/80), and 85.6% (137/160), respectively Tumors in HSC images of 13 (81.3%) cases were well enhanced by image processing Differences in spectral reflectance between tumors and normal mucosa suggested that tumors can be clearly distinguished from background mucosa with HSI technology.

  12. Advances in the Application of Image Processing Fruit Grading

    OpenAIRE

    Fang , Chengjun; Hua , Chunjian

    2013-01-01

    International audience; In the perspective of actual production, the paper presents the advances in the application of image processing fruit grading from several aspects, such as processing precision and processing speed of image processing technology. Furthermore, the different algorithms about detecting size, shape, color and defects are combined effectively to reduce the complexity of each algorithm and achieve a balance between the processing precision and processing speed are keys to au...

  13. Intravascular ultrasonic-photoacoustic (IVUP) endoscope with 2.2-mm diameter catheter for medical imaging.

    Science.gov (United States)

    Bui, Nhat Quang; Hlaing, Kyu Kyu; Nguyen, Van Phuc; Nguyen, Trung Hau; Oh, Yun-Ok; Fan, Xiao Feng; Lee, Yong Wook; Nam, Seung Yun; Kang, Hyun Wook; Oh, Junghwan

    2015-10-01

    Intravascular ultrasound (IVUS) imaging is extremely important for detection and characterization of high-risk atherosclerotic plaques as well as gastrointestinal diseases. Recently, intravascular photoacoustic (IVPA) imaging has been used to differentiate the composition of biological tissues with high optical contrast and ultrasonic resolution. The combination of these imaging techniques could provide morphological information and molecular screening to characterize abnormal tissues, which would help physicians to ensure vital therapeutic value and prognostic significance for patients before commencing therapy. In this study, integration of a high-frequency IVUS imaging catheter (45MHz, single-element, unfocused, 0.7mm in diameter) with a multi-mode optical fiber (0.6mm in core diameter, 0.22 NA), an integrated intravascular ultrasonic-photoacoustic (IVUP) imaging catheter, was developed to provide spatial and functional information on light distribution in a turbid sample. Simultaneously, IVUS imaging was co-registered to IVPA imaging to construct 3D volumetric sample images. In a phantom study, a polyvinyl alcohol (PVA) tissue-mimicking arterial vessel phantom with indocyanine green (ICG) and methylene blue (MB) inclusion was used to demonstrate the feasibility of mapping the biological dyes, which are used in cardiovascular and cancer diagnostics. For the ex vivo study, an excised sample of pig intestine with ICG was utilized to target the biomarkers present in the gastrointestinal tumors or the atherosclerotic plaques with the proposed hybrid technique. The results indicated that IVUP endoscope with the 2.2-mm diameter catheter could be a useful tool for medical imaging. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.

    Science.gov (United States)

    Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M

    2018-02-01

    Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.

  15. Smart imaging of acute lung injury: exploration of myeloperoxidase activity using in vivo endoscopic confocal fluorescence microscopy.

    Science.gov (United States)

    Chagnon, Frédéric; Bourgouin, Alexandra; Lebel, Réjean; Bonin, Marc-André; Marsault, Eric; Lepage, Martin; Lesur, Olivier

    2015-09-15

    The pathophysiology of acute lung injury (ALI) is well characterized, but its real-time assessment at bedside remains a challenge. When patients do not improve after 1 wk despite supportive therapies, physicians have to consider open lung biopsy (OLB) to identify the process(es) at play. Sustained inflammation and inadequate repair are often observed in this context. OLB is neither easy to perform in a critical setting nor exempt from complications. Herein, we explore intravital endoscopic confocal fluorescence microscopy (ECFM) of the lung in vivo combined with the use of fluorescent smart probe(s) activated by myeloperoxidase (MPO). MPO is a granular enzyme expressed by polymorphonuclear neutrophils (PMNs) and alveolar macrophages (AMs), catalyzing the synthesis of hypoclorous acid, a by-product of hydrogen peroxide. Activation of these probes was first validated in vitro in relevant cells (i.e., AMs and PMNs) and on MPO-non-expressing cells (as negative controls) and then tested in vivo using three rat models of ALI and real-time intravital imaging with ECFM. Semiquantitative image analyses revealed that in vivo probe-related cellular/background fluorescence was associated with corresponding enhanced lung enzymatic activity and was partly prevented by specific MPO inhibition. Additional ex vivo phenotyping was performed, confirming that fluorescent cells were neutrophil elastase(+) (PMNs) or CD68(+) (AMs). This work is a first step toward "virtual biopsy" of ALI without OLB. Copyright © 2015 the American Physiological Society.

  16. Limiting liability via high resolution image processing

    Energy Technology Data Exchange (ETDEWEB)

    Greenwade, L.E.; Overlin, T.K.

    1996-12-31

    The utilization of high resolution image processing allows forensic analysts and visualization scientists to assist detectives by enhancing field photographs, and by providing the tools and training to increase the quality and usability of field photos. Through the use of digitized photographs and computerized enhancement software, field evidence can be obtained and processed as `evidence ready`, even in poor lighting and shadowed conditions or darkened rooms. These images, which are most often unusable when taken with standard camera equipment, can be shot in the worst of photographic condition and be processed as usable evidence. Visualization scientists have taken the use of digital photographic image processing and moved the process of crime scene photos into the technology age. The use of high resolution technology will assist law enforcement in making better use of crime scene photography and positive identification of prints. Valuable court room and investigation time can be saved and better served by this accurate, performance based process. Inconclusive evidence does not lead to convictions. Enhancement of the photographic capability helps solve one major problem with crime scene photos, that if taken with standard equipment and without the benefit of enhancement software would be inconclusive, thus allowing guilty parties to be set free due to lack of evidence.

  17. Design for embedded image processing on FPGAs

    CERN Document Server

    Bailey, Donald G

    2011-01-01

    "Introductory material will consider the problem of embedded image processing, and how some of the issues may be solved using parallel hardware solutions. Field programmable gate arrays (FPGAs) are introduced as a technology that provides flexible, fine-grained hardware that can readily exploit parallelism within many image processing algorithms. A brief review of FPGA programming languages provides the link between a software mindset normally associated with image processing algorithms, and the hardware mindset required for efficient utilization of a parallel hardware design. The bulk of the book will focus on the design process, and in particular how designing an FPGA implementation differs from a conventional software implementation. Particular attention is given to the techniques for mapping an algorithm onto an FPGA implementation, considering timing, memory bandwidth and resource constraints, and efficient hardware computational techniques. Extensive coverage will be given of a range of image processing...

  18. Endoscopic root canal treatment.

    Science.gov (United States)

    Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded

    2009-10-01

    To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.

  19. Pneumoretroperitoneum and Sepsis After Transanal Endoscopic Resection of a Rectal Lateral Spreading Tumor

    Science.gov (United States)

    Coura, Marcelo de Melo Andrade; de Almeida, Romulo Medeiros; Moreira, Natascha Mourão; de Sousa, João Batista; de Oliveira, Paulo Gonçalves

    2017-01-01

    Transanal endoscopic microsurgery is considered a safe, appropriate, and minimally invasive approach, and complications after endoscopic microsurgery are rare. We report a case of sepsis and pneumoretroperitoneum after resection of a rectal lateral spreading tumor. The patient presented with rectal mucous discharge. Colonoscopy revealed a rectal lateral spreading tumor. The patient underwent an endoscopic transanal resection of the lesion. He presented with sepsis of the abdominal focus, and imaging tests revealed pneumoretroperitoneum. A new surgical intervention was performed with a loop colostomy. Despite the existence of other reports on pneumoretroperitoneum after transanal endoscopic microsurgery, what draws attention to this case is the association with sepsis. PMID:28761873

  20. [Transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess].

    Science.gov (United States)

    Yu, Huanxin; Liu, Gang

    2014-01-01

    To evaluate the effectiveness of transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess. Eighteen pathologically diagnosed pituitary abscess were resected through transsphenoidal endoscopic endonasal approach at Tianjing Huanhu hospital between January 2000 and December 2011.Retrospective analysis was done upon clinical presentations and imaging features. There were 6 males and 12 females. The average age was 48.5 years old and the average disease course was 5.8 years. The typical clinical manifestations included headache (13 cases), pituitary dysfunction (10 cases), Diabetes Insipidus (4 cases) visual interference (8 cases) and fever (4 cases). All cases were resected by transsphenoidal endoscopic endonasal approach with general anesthesia. The postoperative symptoms and follow-up results were recorded. All patients were followed up from 6 months to 6 years. Postoperatively, headache was recovered in 13 cases, visual was improved in 6 cases, hypopituitarism was relieved in 8 cases and polyuria was disappeared in 3 cases. One case was recurrent and cured by transsphenoidal endoscopic endonasal approach. Transsphenoidal endoscopic endonasal approach for the surgery of pituitary abscess is effective.

  1. [Research on the range of motion measurement system for spine based on LabVIEW image processing technology].

    Science.gov (United States)

    Li, Xiaofang; Deng, Linhong; Lu, Hu; He, Bin

    2014-08-01

    A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 Nm to 5 Nm. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.

  2. Imaging in the Evaluation of Endoscopic or Surgical Treatment for Achalasia

    Directory of Open Access Journals (Sweden)

    Diego Palladino

    2016-01-01

    Full Text Available Purpose. Aim of the study is to evaluate the efficacy of the endoscopic (pneumatic dilation versus surgical (Heller myotomy treatment in patients affected by esophageal achalasia using barium X-ray examination of the digestive tract performed before and after the treatment. Materials and Methods. 19 patients (10 males and 9 females were enrolled in this study; each patient underwent a barium X-ray examination to evaluate the esophageal diameter and the height of the barium column before and after endoscopic or surgical treatment. Results. The mean variation of oesophageal diameter before and after treatment is −2.1 mm for surgery and 1.74 mm for pneumatic dilation (OR 0.167, CI 95% 0.02–1.419, and P: 0.10. The variations of all variables, with the exception of the oesophageal diameter variation, are strongly related to the treatment performed. Conclusions. The barium X-ray study of the digestive tract, performed before and after different treatment approaches, demonstrates that the surgical treatment has to be considered as the treatment of choice of achalasia, reserving endoscopic treatment to patients with high operative risk and refusing surgery.

  3. Optical fiber-based full Mueller polarimeter for endoscopic imaging using a two-wavelength simultaneous measurement method.

    Science.gov (United States)

    Vizet, Jérémy; Manhas, Sandeep; Tran, Jacqueline; Validire, Pierre; Benali, Abdelali; Garcia-Caurel, Enric; Pierangelo, Angelo; De Martino, Antonello; Pagnoux, Dominique

    2016-07-01

    This paper reports a technique based on spectrally differential measurement for determining the full Mueller matrix of a biological sample through an optical fiber. In this technique, two close wavelengths were used simultaneously, one for characterizing the fiber and the other for characterizing the assembly of fiber and sample. The characteristics of the fiber measured at one wavelength were used to decouple its contribution from the measurement on the assembly of fiber and sample and then to extract sample Mueller matrix at the second wavelength. The proof of concept was experimentally validated by measuring polarimetric parameters of various calibrated optical components through the optical fiber. Then, polarimetric images of histological cuts of human colon tissues were measured, and retardance, diattenuation, and orientation of the main axes of fibrillar regions were displayed. Finally, these images were successfully compared with images obtained by a free space Mueller microscope. As the reported method does not use any moving component, it offers attractive integration possibilities with an endoscopic probe.

  4. Gastric adenocarcinoma screening and prevention in the era of new biomarker and endoscopic technologies: a cost-effectiveness analysis.

    Science.gov (United States)

    Yeh, Jennifer M; Hur, Chin; Ward, Zachary; Schrag, Deborah; Goldie, Sue J

    2016-04-01

    To estimate the cost-effectiveness of noncardia gastric adenocarcinoma (NCGA) screening strategies based on new biomarker and endoscopic technologies. Using an intestinal-type NCGA microsimulation model, we evaluated the following one-time screening strategies for US men: (1) serum pepsinogen to detect gastric atrophy (with endoscopic follow-up of positive screen results), (2) endoscopic screening to detect dysplasia and asymptomatic cancer (with endoscopic mucosal resection (EMR) treatment for detected lesions) and (3) Helicobacter pylori screening and treatment. Screening performance, treatment effectiveness, cancer and cost data were based on published literature and databases. Subgroups included current, former and never smokers. Outcomes included lifetime cancer risk and incremental cost-effectiveness ratios (ICERs), expressed as cost per quality-adjusted-life-year (QALY) gained. Screening the general population at age 50 years reduced the lifetime intestinal-type NCGA risk (0.24%) by 26.4% with serum pepsinogen screening, 21.2% with endoscopy and EMR and 0.2% with H. pylori screening/treatment. Targeting current smokers reduced the lifetime risk (0.35%) by 30.8%, 25.5%, and 0.1%, respectively. For all subgroups, serum pepsinogen screening was more effective and more cost-effective than all other strategies, although its ICER varied from $76,000/QALY (current smokers) to $105,400/QALY (general population). Results were sensitive to H. pylori prevalence, screen age and serum pepsinogen test sensitivity. Probabilistic sensitivity analysis found that at a $100,000/QALY willingness-to-pay threshold, the probability that serum pepsinogen screening was preferred was 0.97 for current smokers. Although not warranted for the general population, targeting high-risk smokers for serum pepsinogen screening may be a cost-effective strategy to reduce intestinal-type NCGA mortality. Published by the BMJ Publishing Group Limited. For permission to use (where not already

  5. OPTICAL correlation identification technology applied in underwater laser imaging target identification

    Science.gov (United States)

    Yao, Guang-tao; Zhang, Xiao-hui; Ge, Wei-long

    2012-01-01

    The underwater laser imaging detection is an effective method of detecting short distance target underwater as an important complement of sonar detection. With the development of underwater laser imaging technology and underwater vehicle technology, the underwater automatic target identification has gotten more and more attention, and is a research difficulty in the area of underwater optical imaging information processing. Today, underwater automatic target identification based on optical imaging is usually realized with the method of digital circuit software programming. The algorithm realization and control of this method is very flexible. However, the optical imaging information is 2D image even 3D image, the amount of imaging processing information is abundant, so the electronic hardware with pure digital algorithm will need long identification time and is hard to meet the demands of real-time identification. If adopt computer parallel processing, the identification speed can be improved, but it will increase complexity, size and power consumption. This paper attempts to apply optical correlation identification technology to realize underwater automatic target identification. The optics correlation identification technology utilizes the Fourier transform characteristic of Fourier lens which can accomplish Fourier transform of image information in the level of nanosecond, and optical space interconnection calculation has the features of parallel, high speed, large capacity and high resolution, combines the flexibility of calculation and control of digital circuit method to realize optoelectronic hybrid identification mode. We reduce theoretical formulation of correlation identification and analyze the principle of optical correlation identification, and write MATLAB simulation program. We adopt single frame image obtained in underwater range gating laser imaging to identify, and through identifying and locating the different positions of target, we can improve

  6. Craniofacial imaging informatics and technology development.

    Science.gov (United States)

    Vannier, M W

    2003-01-01

    'Craniofacial imaging informatics' refers to image and related scientific data from the dentomaxillofacial complex, and application of 'informatics techniques' (derived from disciplines such as applied mathematics, computer science and statistics) to understand and organize the information associated with the data. Major trends in information technology determine the progress made in craniofacial imaging and informatics. These trends include industry consolidation, disruptive technologies, Moore's law, electronic atlases and on-line databases. Each of these trends is explained and documented, relative to their influence on craniofacial imaging. Craniofacial imaging is influenced by major trends that affect all medical imaging and related informatics applications. The introduction of cone beam craniofacial computed tomography scanners is an example of a disruptive technology entering the field. An important opportunity lies in the integration of biologic knowledge repositories with craniofacial images. The progress of craniofacial imaging will continue subject to limitations imposed by the underlying technologies, especially imaging informatics. Disruptive technologies will play a major role in the evolution of this field.

  7. Recent progress in medical imaging technology

    International Nuclear Information System (INIS)

    Endo, Masahiro

    2004-01-01

    Medical imaging is name of methods for diagnosis and therapy, which make visible with physical media such as X-ray, structures and functions of man's inside those are usually invisible. These methods are classified by the physical media into ultrasound imaging, magnetic resonance imaging, nuclear medicine imaging and X-ray imaging etc. Having characteristics different from one another, these are used complementarily in medical fields though in some case being competitive. Medical imaging is supported by highly progressed technology, which is called medical imaging technology. This paper describes a survey of recent progress of medical imaging technology in magnetic resonance imaging, nuclear medicine imaging and X-ray imaging. (author)

  8. Automatic real-time detection of endoscopic procedures using temporal features.

    Science.gov (United States)

    Stanek, Sean R; Tavanapong, Wallapak; Wong, Johnny; Oh, Jung Hwan; de Groen, Piet C

    2012-11-01

    Endoscopy is used for inspection of the inner surface of organs such as the colon. During endoscopic inspection of the colon or colonoscopy, a tiny video camera generates a video signal, which is displayed on a monitor for interpretation in real-time by physicians. In practice, these images are not typically captured, which may be attributed by lack of fully automated tools for capturing, analysis of important contents, and quick and easy retrieval of these contents. This paper presents the description and evaluation results of our novel software that uses new metrics based on image color and motion over time to automatically record all images of an individual endoscopic procedure into a single digitized video file. The software automatically discards out-patient video frames between different endoscopic procedures. We validated our software system on 2464 h of live video (over 265 million frames) from endoscopy units where colonoscopy and upper endoscopy were performed. Our previous classification method achieved a frame-based sensitivity of 100.00%, but only a specificity of 89.22%. Our new method achieved a frame-based sensitivity and specificity of 99.90% and 99.97%, a significant improvement. Our system is robust for day-to-day use in medical practice. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Endoscopic retrograde cholanglopancreatography

    International Nuclear Information System (INIS)

    Horii, S.C.; Garra, B.S.; Zeman, R.K.; Krasner, B.H.; Lo, S.C.B.; Davros, W.J.; Silverman, P.M.; Cattau, E.L.; Fleischer, D.E.; Benjamin, S.B.S.B.

    1989-01-01

    As part of the clinical evaluation of image management and communications system (IMACS), the authors undertook a prospective study to compare conventional film versus digitized film viewed on a workstation. Twenty-five each of normal and abnormal endoscopic retrograde cholangiopancreatographic (ERCP) studies were digitized with a 1,684 x 2,048-pixel matrix and evaluated in a single-blind fashion on the workstation. The resulting interpretations were then compared with those resulting from interpretation of film (spot film and 100-mm photospot) images. They report that no significant differences were found in ability to see anatomic detail or pathology. A second study involved performing 10 ERCP studies in a lithotripsy suite equipped with biplane digital fluoroscopy. The digital video displays were comparable in quality to that of film. Progress is being made in using the IMACS for archiving and retrieval of all current ERCP images

  10. Imaging technologies to study the composition of live pigs: A review

    Directory of Open Access Journals (Sweden)

    Anna Carabús

    2016-08-01

    Full Text Available Image techniques are increasingly being applied to livestock animals. This paper overviews recent advances in image processing analysis for live pigs, including ultrasound, visual image analysis by monitoring, dual-energy X-ray absorptiometry, magnetic resonance imaging and computed tomography. The methodology for live pigs evaluation, advantages and disadvantages of different devices, the variables and measurements analysed, the predictions obtained using these measurements and their accuracy are discussed in the present paper. Utilities of these technologies for livestock purposes are also reviewed. Computed tomography and magnetic resonance imaging yield useful results for the estimation of the amount of fat and lean mass either in live pigs or in carcasses. Ultrasound is not sufficiently accurate when high precision in estimating pig body composition is necessary but can provide useful information in agriculture to classify pigs for breeding purposes or before slaughter. Improvements in factors, such as the speed of scanning, cost and image accuracy and processing, would advance the application of image processing technologies in livestock animals.

  11. Interactive navigation-guided ophthalmic plastic surgery: navigation enabling of telescopes and their use in endoscopic lacrimal surgeries

    Directory of Open Access Journals (Sweden)

    Ali MJ

    2016-11-01

    Full Text Available Mohammad Javed Ali,1 Swati Singh,1 Milind N Naik,1 Swathi Kaliki,2 Tarjani Vivek Dave1 1The Institute of Dacryology, 2The Operation Eyesight Universal Institute for Eye Cancer, L.V. Prasad Eye Institute, Hyderabad, India Purpose: The aims of this study were to report the preliminary experience of using telescopes, which were enabled for navigation guidance, and their utility in complex endoscopic lacrimal surgeries. Methods: Navigation enabling of the telescope was achieved by using the AxiEM™ malleable neuronavigation shunt stylet. Image-guided dacryolocalization was performed in five patients using the intraoperative image-guided StealthStation™ system in the electromagnetic mode. The “look ahead” protocol software was used to assist the surgeon in assessing the intraoperative geometric location of the endoscope and what lies ahead in real time. All patients underwent navigation-guided powered endoscopic dacryocystorhinostomy. The utility of uninterrupted navigation guidance throughout the surgery with the endoscope as the navigating tool was noted. Results: Intraoperative geometric localization of the lacrimal sac and the nasolacrimal duct could be easily deciphered. Constant orientation of the lacrimal drainage system and the peri-lacrimal anatomy was possible without the need for repeated point localizations throughout the surgery. The “look ahead” features could accurately alert the surgeon of anatomical structures that exists at 5, 10 and 15 mm in front of the endoscope. Good securing of the shunt stylet with the telescope was found to be essential for constant and accurate navigation. Conclusion: Navigation-enabled endoscopes provide the surgeon with the advantage of sustained stereotactic anatomical awareness at all times during the surgery. Keywords: telescope, endoscope, image guidance, navigation, lacrimal surgery, powered endoscopic DCR

  12. Multimodal Navigation in Endoscopic Transsphenoidal Resection of Pituitary Tumors Using Image-Based Vascular and Cranial Nerve Segmentation: A Prospective Validation Study.

    Science.gov (United States)

    Dolati, Parviz; Eichberg, Daniel; Golby, Alexandra; Zamani, Amir; Laws, Edward

    2016-11-01

    Transsphenoidal surgery (TSS) is the most common approach for the treatment of pituitary tumors. However, misdirection, vascular damage, intraoperative cerebrospinal fluid leakage, and optic nerve injuries are all well-known complications, and the risk of adverse events is more likely in less-experienced hands. This prospective study was conducted to validate the accuracy of image-based segmentation coupled with neuronavigation in localizing neurovascular structures during TSS. Twenty-five patients with a pituitary tumor underwent preoperative 3-T magnetic resonance imaging (MRI), and MRI images loaded into the navigation platform were used for segmentation and preoperative planning. After patient registration and subsequent surgical exposure, each segmented neural or vascular element was validated by manual placement of the navigation probe or Doppler probe on or as close as possible to the target. Preoperative segmentation of the internal carotid artery and cavernous sinus matched with the intraoperative endoscopic and micro-Doppler findings in all cases. Excellent correspondence between image-based segmentation and the endoscopic view was also evident at the surface of the tumor and at the tumor-normal gland interfaces. Image guidance assisted the surgeons in localizing the optic nerve and chiasm in 64% of cases. The mean accuracy of the measurements was 1.20 ± 0.21 mm. Image-based preoperative vascular and neural element segmentation, especially with 3-dimensional reconstruction, is highly informative preoperatively and potentially could assist less-experienced neurosurgeons in preventing vascular and neural injury during TSS. In addition, the accuracy found in this study is comparable to previously reported neuronavigation measurements. This preliminary study is encouraging for future prospective intraoperative validation with larger numbers of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Advances in low-level color image processing

    CERN Document Server

    Smolka, Bogdan

    2014-01-01

    Color perception plays an important role in object recognition and scene understanding both for humans and intelligent vision systems. Recent advances in digital color imaging and computer hardware technology have led to an explosion in the use of color images in a variety of applications including medical imaging, content-based image retrieval, biometrics, watermarking, digital inpainting, remote sensing, visual quality inspection, among many others. As a result, automated processing and analysis of color images has become an active area of research, to which the large number of publications of the past two decades bears witness. The multivariate nature of color image data presents new challenges for researchers and practitioners as the numerous methods developed for single channel images are often not directly applicable to multichannel  ones. The goal of this volume is to summarize the state-of-the-art in the early stages of the color image processing pipeline.

  14. Sphincter of Oddi stenosis: diagnosis using hepatobiliary scintigraphy and endoscopic manometry

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Gregg, J.A.; Koroshetz, A.M.; Hill, T.C.; Clouse, M.E.

    1985-01-01

    To determine the role of radionuclide imaging in diagnosing sphincter of Oddi stenosis, 21 patients with symptoms suggesting this disorder underwent endoscopic retrograde cholangiopancreatography, cholescintigraphy, and, when possible, endoscopic manometry. Those patients with abnormal hepatobiliary scintigraphy results had a mean basal sphincter pressure of 38.5 mm Hg. Sphincter pressures could not be measured in six patients with sphincters too tight to cannulate. Ten patients who underwent hepatobiliary scanning both before and after sphincter surgery had normal scan results of the repeat study. Hepatobiliary imaging appears useful for diagnosis of sphincter of Oddi stenosis in selected patients in whom manometry cannot be performed and for objective assessment of response to therapy

  15. [Current Status of Endoscopic Resection of Early Gastric Cancer in Korea].

    Science.gov (United States)

    Jung, Hwoon Yong

    2017-09-25

    Endoscopic resection (Endoscopic mucosal resection [EMR] and endoscopic submucosal dissection [ESD]) is already established as a first-line treatment modality for selected early gastric cancer (EGC). In Korea, the number of endoscopic resection of EGC was explosively increased because of a National Cancer Screening Program and development of devices and techniques. There were many reports on the short-term and long-term outcomes after endoscopic resection in patients with EGC. Long-term outcome in terms of recurrence and death is excellent in both absolute and selected expanded criteria. Furthermore, endoscopic resection might be positioned as primary treatment modality replacing surgical gastrectomy. To obtain these results, selection of patients, perfect en bloc procedure, thorough pathological examination of resected specimen, accurate interpretation of whole process of endoscopic resection, and rational strategy for follow-up is necessary.

  16. Update on endoscopic pancreatic function testing

    Institute of Scientific and Technical Information of China (English)

    Tyler Stevens; Mansour A Parsi

    2011-01-01

    Hormone-stimulated pancreatic function tests (PFTs) are considered the gold standard for measuring pancreatic exocrine function. PFTs involve the administration of intravenous secretin or cholecystokinin, followed by collection and analysis of pancreatic secretions. Because exocrine function may decline in the earliest phase of pancreatic fibrosis, PFTs are considered accurate for diagnosing chronic pancreatitis. Unfortunately, these potentially valuable tests are infrequently performed except at specialized centers, because they are time consuming and complicated. To overcome these limitations, endoscopic PFT methods have been developed which include aspiration of pancreatic secretions through the suction channel of the endoscope. The secretin endoscopic pancreatic function test (ePFT) involves collection of duodenal aspirates at 15, 30, 45 and 60 min after secretin stimulation. A bicarbonate concentration greater than 80 mmol/L in any of the samples is considered a normal result. The secretin ePFT has demonstrated good sensitivity and specificity compared with various reference standards, including the "Dreiling tube" secretin PFT, endoscopic ultrasound, and surgical histology. Furthermore, a standard autoanalyzer can be used for bicarbonate analysis, which allows the secretin ePFT to be performed at any hospital. The secretin ePFT may complement imaging tests like endoscopic ultrasound (EUS) in the diagnosis of early chronic pancreatitis.This paper will review the literature validating the use of ePFT in the diagnosis of exocrine insufficiency and chronic pancreatitis. Newer developments will also be discussed, including the feasibility of combined EUS/ePFT, the use of cholecystokinin alone or in combination with secretin, and the discovery of new protein and lipid pancreatic juice biomarkers which may complement traditionalfluid analysis.

  17. Tuberculosis and the pancreas: a diagnostic challenge solved by endoscopic ultrasound. A case series.

    Science.gov (United States)

    Chatterjee, Suvadip; Schmid, Matthias L; Anderson, Kirsty; Oppong, Kofi W

    2012-03-01

    Pancreatic tuberculosis is a rare disease. It can be easily confused with malignancy or pancreatitis on imaging. This could result in unnecessary surgery. As this is a treatable disease it is imperative to diagnose this condition pre-operatively. We report three cases of pancreatic tuberculosis that were diagnosed by endoscopic ultrasound. In conclusion, endoscopic ultrasound is the diagnostic modality of choice for pancreatic tuberculosis facilitating high resolution imaging, as well as sampling of tissue for staining, cytology, culture and polymerase chain reaction assay.

  18. Using hyperspectral imaging technology to identify diseased tomato leaves

    Science.gov (United States)

    Li, Cuiling; Wang, Xiu; Zhao, Xueguan; Meng, Zhijun; Zou, Wei

    2016-11-01

    In the process of tomato plants growth, due to the effect of plants genetic factors, poor environment factors, or disoperation of parasites, there will generate a series of unusual symptoms on tomato plants from physiology, organization structure and external form, as a result, they cannot grow normally, and further to influence the tomato yield and economic benefits. Hyperspectral image usually has high spectral resolution, not only contains spectral information, but also contains the image information, so this study adopted hyperspectral imaging technology to identify diseased tomato leaves, and developed a simple hyperspectral imaging system, including a halogen lamp light source unit, a hyperspectral image acquisition unit and a data processing unit. Spectrometer detection wavelength ranged from 400nm to 1000nm. After hyperspectral images of tomato leaves being captured, it was needed to calibrate hyperspectral images. This research used spectrum angle matching method and spectral red edge parameters discriminant method respectively to identify diseased tomato leaves. Using spectral red edge parameters discriminant method produced higher recognition accuracy, the accuracy was higher than 90%. Research results have shown that using hyperspectral imaging technology to identify diseased tomato leaves is feasible, and provides the discriminant basis for subsequent disease control of tomato plants.

  19. Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes

    Directory of Open Access Journals (Sweden)

    Klein Stefanie

    2010-07-01

    Full Text Available Abstract Background The reprocessing of medical endoscopes is carried out using automatic cleaning and disinfection machines. The documentation and archiving of records of properly conducted reprocessing procedures is the last and increasingly important part of the reprocessing cycle for flexible endoscopes. Methods This report describes a new computer program designed to monitor and document the automatic reprocessing of flexible endoscopes and accessories in fully automatic washer-disinfectors; it does not contain nor compensate the manual cleaning step. The program implements national standards for the monitoring of hygiene in flexible endoscopes and the guidelines for the reprocessing of medical products. No FDA approval has been obtained up to now. The advantages of this newly developed computer program are firstly that it simplifies the documentation procedures of medical endoscopes and that it could be used universally with any washer-disinfector and that it is independent of the various interfaces and software products provided by the individual suppliers of washer-disinfectors. Results The computer program presented here has been tested on a total of four washer-disinfectors in more than 6000 medical examinations within 9 months. Conclusions We present for the first time an electronic documentation system for automated washer-disinfectors for medical devices e.g. flexible endoscopes which can be used on any washer-disinfectors that documents the procedures involved in the automatic cleaning process and can be easily connected to most hospital documentation systems.

  20. Endoscopic foraminal decompression for failed back surgery syndrome under local anesthesia.

    Science.gov (United States)

    Yeung, Anthony; Gore, Satishchandra

    2014-01-01

    The most common causes of failed back surgery are residual or recurrent herniation, foraminal fibrosis and foraminal stenosis that is ignored, untreated, or undertreated. Residual back ache may also be from facetal causes or denervation and scarring of the paraspinal muscles.(1-6) The original surgeon may advise his patient that nothing more can be done on the basis of his opinion that the nerve was visually decompressed by the original surgery, supported by improved post-op imaging and follow-up studies such as EMG and conduction velocity studies. Post-op imaging or electrophysiological assessment may be inadequate to explain all the reasons for residual or recurrent symptoms. Treatment of Failed back surgery by repeat traditional open revision surgery usually incorporates more extensive decompression causing increased instability and back pain, therefore necessitating fusion. The authors, having limited their practice to endoscopic MIS surgery over the last 15-20 years, report on their experience gained during that period to relieve pain by endoscopically visualizing and treating unrecognized causative patho-anatomy in FBSS.(7.) Thirty consecutive patients with FBSS presenting with back and leg pain that had supporting imaging diagnosis of lateral stenosis and /or residual / recurrent disc herniation, or whose pain complaint was supported by relief from diagnostic and therapeutic injections (Figure 1), were offered percutaneous transforaminal endoscopic discectomy and foraminoplasty over a repeat open procedure. Each patient sought consultation following a transient successful, partially successful or unsuccessful open translaminar surgical treatment for disc herniation or spinal stenosis. Endoscopic foraminoplasty was also performed to either decompress the bony foramen for foraminal stenosis, or foraminoplasty to allow for endoscopic visual examination of the affected traversing and exiting nerve roots in the axilla, also known as the "hidden zone" of Macnab

  1. Crack detection using image processing

    International Nuclear Information System (INIS)

    Moustafa, M.A.A

    2010-01-01

    This thesis contains five main subjects in eight chapters and two appendices. The first subject discus Wiener filter for filtering images. In the second subject, we examine using different methods, as Steepest Descent Algorithm (SDA) and the Wavelet Transformation, to detect and filling the cracks, and it's applications in different areas as Nano technology and Bio-technology. In third subject, we attempt to find 3-D images from 1-D or 2-D images using texture mapping with Open Gl under Visual C ++ language programming. The fourth subject consists of the process of using the image warping methods for finding the depth of 2-D images using affine transformation, bilinear transformation, projective mapping, Mosaic warping and similarity transformation. More details about this subject will be discussed below. The fifth subject, the Bezier curves and surface, will be discussed in details. The methods for creating Bezier curves and surface with unknown distribution, using only control points. At the end of our discussion we will obtain the solid form, using the so called NURBS (Non-Uniform Rational B-Spline); which depends on: the degree of freedom, control points, knots, and an evaluation rule; and is defined as a mathematical representation of 3-D geometry that can accurately describe any shape from a simple 2-D line, circle, arc, or curve to the most complex 3-D organic free-form surface or (solid) which depends on finding the Bezier curve and creating family of curves (surface), then filling in between to obtain the solid form. Another representation for this subject is concerned with building 3D geometric models from physical objects using image-based techniques. The advantage of image techniques is that they require no expensive equipment; we use NURBS, subdivision surface and mesh for finding the depth of any image with one still view or 2D image. The quality of filtering depends on the way the data is incorporated into the model. The data should be treated with

  2. The transition from microscopic to endoscopic transsphenoidal surgery: the experience at Brigham and Women's Hospital.

    Science.gov (United States)

    Laws, Edward R; Barkhoudarian, Garni

    2014-12-01

    As interest and enthusiasm for the use of the endoscope in transsphenoidal anterior skull base and pituitary surgery increases, neurosurgeons are increasingly adopting endoscopic technology and associated novel concepts. Often this involves a transition from the standard operating microscope as the main means of visualization to the operating endoscope (2D or 3D) during surgery. The authors' experience with this transition is described, including the rationale, advantages and disadvantages of the two surgical techniques. The successful use of endoscopic surgery for a large variety of pathological problems involving the anterior skull base and the pituitary region is presented. Perceived advantages for the patient and the surgeon are described, as is the occasional need for transition back to the microscopic approach. The endoscopic approach and its allied technology are here to stay. They are useful and occasionally preferable methods for treating a variety of suitable lesions involving the anterior skull base. The importance of incorporating the basic principles of skull base surgery is emphasized. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. A new concept for medical imaging centered on cellular phone technology.

    Directory of Open Access Journals (Sweden)

    Yair Granot

    2008-04-01

    Full Text Available According to World Health Organization reports, some three quarters of the world population does not have access to medical imaging. In addition, in developing countries over 50% of medical equipment that is available is not being used because it is too sophisticated or in disrepair or because the health personnel are not trained to use it. The goal of this study is to introduce and demonstrate the feasibility of a new concept in medical imaging that is centered on cellular phone technology and which may provide a solution to medical imaging in underserved areas. The new system replaces the conventional stand-alone medical imaging device with a new medical imaging system made of two independent components connected through cellular phone technology. The independent units are: a a data acquisition device (DAD at a remote patient site that is simple, with limited controls and no image display capability and b an advanced image reconstruction and hardware control multiserver unit at a central site. The cellular phone technology transmits unprocessed raw data from the patient site DAD and receives and displays the processed image from the central site. (This is different from conventional telemedicine where the image reconstruction and control is at the patient site and telecommunication is used to transmit processed images from the patient site. The primary goal of this study is to demonstrate that the cellular phone technology can function in the proposed mode. The feasibility of the concept is demonstrated using a new frequency division multiplexing electrical impedance tomography system, which we have developed for dynamic medical imaging, as the medical imaging modality. The system is used to image through a cellular phone a simulation of breast cancer tumors in a medical imaging diagnostic mode and to image minimally invasive tissue ablation with irreversible electroporation in a medical imaging interventional mode.

  4. Liver parenchumography following endoscopic retrograde cholangiopancreatography (ERCP)

    International Nuclear Information System (INIS)

    Revert, A.; Arana, E.; Pertejo, V.; Berenguer, M.; Masip, M.J.

    1998-01-01

    Focal liver opacification during endoscopic retrograde cholangiography (ERCP) is an uncommon complication caused by excessive pressure during contrast injection. In this situation, ERCP must be interrupted and the position of the cannula checked. We recommend that these images be excluded from the diagnosis of tumor or cystic cavities. 4 refs

  5. Computational surgery and dual training computing, robotics and imaging

    CERN Document Server

    Bass, Barbara; Berceli, Scott; Collet, Christophe; Cerveri, Pietro

    2014-01-01

    This critical volume focuses on the use of medical imaging, medical robotics, simulation, and information technology in surgery. It offers a road map for computational surgery success,  discusses the computer-assisted management of disease and surgery, and provides a rational for image processing and diagnostic. This book also presents some advances on image-driven intervention and robotics, as well as evaluates models and simulations for a broad spectrum of cancers as well as cardiovascular, neurological, and bone diseases. Training and performance analysis in surgery assisted by robotic systems is also covered. This book also: ·         Provides a comprehensive overview of the use of computational surgery and disease management ·         Discusses the design and use of medical robotic tools for orthopedic surgery, endoscopic surgery, and prostate surgery ·         Provides practical examples and case studies in the areas of image processing, virtual surgery, and simulation traini...

  6. Recent advances in imaging technologies in dentistry

    Institute of Scientific and Technical Information of China (English)

    Naseem; Shah; Nikhil; Bansal; Ajay; Logani

    2014-01-01

    Dentistry has witnessed tremendous advances in all its branches over the past three decades. With these advances, the need for more precise diagnostic tools,specially imaging methods, have become mandatory.From the simple intra-oral periapical X-rays, advanced imaging techniques like computed tomography, cone beam computed tomography, magnetic resonance imaging and ultrasound have also found place in modern dentistry. Changing from analogue to digital radiography has not only made the process simpler and faster but also made image storage, manipulation(brightness/contrast, image cropping, etc.) and retrieval easier. The three-dimensional imaging has made the complex cranio-facial structures more accessible for examination and early and accurate diagnosis of deep seated lesions. This paper is to review current advances in imaging technology and their uses in different disciplines of dentistry.

  7. Ultrathin endoscopes based on multicore fibers and adaptive optics: a status review and perspectives.

    Science.gov (United States)

    Andresen, Esben Ravn; Sivankutty, Siddharth; Tsvirkun, Viktor; Bouwmans, Géraud; Rigneault, Hervé

    2016-12-01

    We take stock of the progress that has been made into developing ultrathin endoscopes assisted by wave front shaping. We focus our review on multicore fiber-based lensless endoscopes intended for multiphoton imaging applications. We put the work into perspective by comparing with alternative approaches and by outlining the challenges that lie ahead.

  8. NeuroSeek dual-color image processing infrared focal plane array

    Science.gov (United States)

    McCarley, Paul L.; Massie, Mark A.; Baxter, Christopher R.; Huynh, Buu L.

    1998-09-01

    Several technologies have been developed in recent years to advance the state of the art of IR sensor systems including dual color affordable focal planes, on-focal plane array biologically inspired image and signal processing techniques and spectral sensing techniques. Pacific Advanced Technology (PAT) and the Air Force Research Lab Munitions Directorate have developed a system which incorporates the best of these capabilities into a single device. The 'NeuroSeek' device integrates these technologies into an IR focal plane array (FPA) which combines multicolor Midwave IR/Longwave IR radiometric response with on-focal plane 'smart' neuromorphic analog image processing. The readout and processing integrated circuit very large scale integration chip which was developed under this effort will be hybridized to a dual color detector array to produce the NeuroSeek FPA, which will have the capability to fuse multiple pixel-based sensor inputs directly on the focal plane. Great advantages are afforded by application of massively parallel processing algorithms to image data in the analog domain; the high speed and low power consumption of this device mimic operations performed in the human retina.

  9. Photon technology. Laser processing technology; Photon technology. Laser process gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Survey has been conducted to develop laser processing technology utilizing the interaction between substance and photon. This is a part of the leading research on photon technology development. The photon technology development is aimed at novel technology development highly utilizing the quantum nature of photons. In the field of laser processing, high quality photons are used as tools, special functions of atoms and molecules will be discovered, and processing for functional fabrication (photon machining) will be established. A role of laser processing in industries has become significant, which is currently spreading not only into cutting and welding of materials and scalpels but also into such a special field as ultrafine processing of materials. The spreading is sometimes obstructed due to the difficulty of procurement of suitable machines and materials, and the increase of cost. The purpose of this study is to develop the optimal laser technology, to elucidate the interaction between substance and photon, and to develop the laser system and the transmission and regulation systems which realize the optimal conditions. 387 refs., 115 figs., 25 tabs.

  10. Transforaminal Percutaneous Endoscopic Discectomy and Foraminoplasty after Lumbar Spinal Fusion Surgery.

    Science.gov (United States)

    Wu, Jian-Jun; Chen, Hui-Zhen; Zheng, Changkun

    2017-07-01

    The most common causes of pain following lumbar spinal fusions are residual herniation, or foraminal fibrosis and foraminal stenosis that is ignored, untreated, or undertreated. The original surgeon may advise his patient that nothing more can be done in his opinion that the nerve was visually decompressed by the original surgery. Post-operative imaging or electrophysiological assessment may be inadequate to explain all the reasons for residual or recurrent symptoms. Treatment of failed lumbar spinal fusions by repeat traditional open revision surgery usually incorporates more extensive decompression causing increased instability and back pain. The authors, having limited their practice to endoscopic surgery over the last 10 years, report on their experience gained during that period to relieve pain by transforaminal percutaneous endoscopic revision of lumbar spinal fusions. To assess the effectiveness of transforaminal percutaneous endoscopic discectomy and foraminoplasty in patients with pain after lumbar spinal fusion. Retrospective study. Inpatient surgery center. Sixteen consecutive patients with pain after lumbar spinal fusions presenting with back and leg pain that had supporting imaging diagnosis of foraminal stenosis and/or residual/recurrent disc herniation, or whose pain complaint was supported by relief from diagnostic and therapeutic injections, were offered percutaneous transforaminal endoscopic discectomy and foraminoplasty over a repeat open procedure. Each patient sought consultation following a transient successful, partially successful or unsuccessful open lumbar spinal fusions treatment for disc herniation or spinal stenosis. Endoscopic foraminoplasty was also performed to either decompress the bony foramen in the case of foraminal stenosis, or to allow for endoscopic visual examination of the affected traversing and exiting nerve roots in the axilla. The average follow-up time was 30.3 months, minimum 12 months. Outcome data at each visit

  11. A Portable Colloidal Gold Strip Sensor for Clenbuterol and Ractopamine Using Image Processing Technology

    Directory of Open Access Journals (Sweden)

    Yi Guo

    2013-01-01

    Full Text Available A portable colloidal golden strip sensor for detecting clenbuterol and ractopamine has been developed using image processing technology, as well as a novel strip reader has achieved innovatively with this imaging sensor. Colloidal gold strips for clenbuterol and ractopamine is used as first sensor with given biomedical immunication reaction. After three minutes the target sample dropped on, the color showing in the T line is relative to the content of objects as clenbuterol, this reader can finish many functions like automatic acquit ion of colored strip image, quantatively analysis of the color lines including the control line and test line, and data storage and transfer to computer. The system is integrated image collection, pattern recognition and real-time colloidal gold quantitative measurement. In experiment, clenbuterol and ractopamine standard substance with concentration from 0 ppb to 10 ppb is prepared and tested, the result reveals that standard solutions of clenbuterol and ractopamine have a good secondary fitting character with color degree (R2 is up to 0.99 and 0.98. Besides, through standard sample addition to the object negative substance, good recovery results are obtained up to 98 %. Above all, an optical sensor for colloidal strip measure is capable of determining the content of clenbuterol and ractopamine, it is likely to apply to quantatively identifying of similar reaction of colloidal golden strips.

  12. Location of disease on imaging may predict radiation exposure during endoscopic retrograde cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Moon Hyung; Jung, Seung Eun; Yoon, Seung Bae; Lee, In Seokand; Byun, Jae Young

    2017-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is performed for various diseases. The aim of this study is to evaluate the difference of dose-area product (DAP) during the ERCP procedures according to location of the lesion. We performed a retrospective study of consecutive 217 therapeutic ERCP examinations performed between November 2014 and April 2015 at a tertiary care center. ERCP procedures divided into two groups according to location of the lesion identified on imaging: lesions in the common hepatic duct (CHD) or the common bile duct (CBD) and lesions in the hepatic hilum or the intrahepatic duct (IHD). The mean DAP of the hilum-IHD group (48.7 Gy cm 2 ) was significantly higher than that of the CBD-CHD group (34.9 Gy cm 2 ) (P = 0.003). Radiation exposure during ERCP was significantly different according to location of bile duct lesion. (authors)

  13. Multimedia image and video processing

    CERN Document Server

    Guan, Ling

    2012-01-01

    As multimedia applications have become part of contemporary daily life, numerous paradigm-shifting technologies in multimedia processing have emerged over the last decade. Substantially updated with 21 new chapters, Multimedia Image and Video Processing, Second Edition explores the most recent advances in multimedia research and applications. This edition presents a comprehensive treatment of multimedia information mining, security, systems, coding, search, hardware, and communications as well as multimodal information fusion and interaction. Clearly divided into seven parts, the book begins w

  14. Image processing with personal computer

    International Nuclear Information System (INIS)

    Hara, Hiroshi; Handa, Madoka; Watanabe, Yoshihiko

    1990-01-01

    The method of automating the judgement works using photographs in radiation nondestructive inspection with a simple type image processor on the market was examined. The software for defect extraction and making binary and the software for automatic judgement were made for trial, and by using the various photographs on which the judgement was already done as the object, the accuracy and the problematic points were tested. According to the state of the objects to be photographed and the condition of inspection, the accuracy of judgement from 100% to 45% was obtained. The criteria for judgement were in conformity with the collection of reference photographs made by Japan Cast Steel Association. In the non-destructive inspection by radiography, the number and size of the defect images in photographs are visually judged, the results are collated with the standard, and the quality is decided. Recently, the technology of image processing with personal computers advanced, therefore by utilizing this technology, the automation of the judgement of photographs was attempted to improve the accuracy, to increase the inspection efficiency and to realize labor saving. (K.I.)

  15. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  16. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  17. A Document Imaging Technique for Implementing Electronic Loan Approval Process

    Directory of Open Access Journals (Sweden)

    J. Manikandan

    2015-04-01

    Full Text Available The image processing is one of the leading technologies of computer applications. Image processing is a type of signal processing, the input for image processor is an image or video frame and the output will be an image or subset of image [1]. Computer graphics and computer vision process uses an image processing techniques. Image processing systems are used in various environments like medical fields, computer-aided design (CAD, research fields, crime investigation fields and military fields. In this paper, we proposed a document image processing technique, for establishing electronic loan approval process (E-LAP [2]. Loan approval process has been tedious process, the E-LAP system attempts to reduce the complexity of loan approval process. Customers have to login to fill the loan application form online with all details and submit the form. The loan department then processes the submitted form and then sends an acknowledgement mail via the E-LAP to the requested customer with the details about list of documents required for the loan approval process [3]. The approaching customer can upload the scanned copies of all required documents. All this interaction between customer and bank take place using an E-LAP system.

  18. Integrating image processing and classification technology into automated polarizing film defect inspection

    Science.gov (United States)

    Kuo, Chung-Feng Jeffrey; Lai, Chun-Yu; Kao, Chih-Hsiang; Chiu, Chin-Hsun

    2018-05-01

    In order to improve the current manual inspection and classification process for polarizing film on production lines, this study proposes a high precision automated inspection and classification system for polarizing film, which is used for recognition and classification of four common defects: dent, foreign material, bright spot, and scratch. First, the median filter is used to remove the impulse noise in the defect image of polarizing film. The random noise in the background is smoothed by the improved anisotropic diffusion, while the edge detail of the defect region is sharpened. Next, the defect image is transformed by Fourier transform to the frequency domain, combined with a Butterworth high pass filter to sharpen the edge detail of the defect region, and brought back by inverse Fourier transform to the spatial domain to complete the image enhancement process. For image segmentation, the edge of the defect region is found by Canny edge detector, and then the complete defect region is obtained by two-stage morphology processing. For defect classification, the feature values, including maximum gray level, eccentricity, the contrast, and homogeneity of gray level co-occurrence matrix (GLCM) extracted from the images, are used as the input of the radial basis function neural network (RBFNN) and back-propagation neural network (BPNN) classifier, 96 defect images are then used as training samples, and 84 defect images are used as testing samples to validate the classification effect. The result shows that the classification accuracy by using RBFNN is 98.9%. Thus, our proposed system can be used by manufacturing companies for a higher yield rate and lower cost. The processing time of one single image is 2.57 seconds, thus meeting the practical application requirement of an industrial production line.

  19. Pseudo-color processing in nuclear medical image

    International Nuclear Information System (INIS)

    Wang Zhiqian; Jin Yongjie

    1992-01-01

    The application of pseudo-color technology in nuclear medical image processing is discussed. It includes selection of the number of pseudo-colors, method of realizing pseudo-color transformation, function of pseudo-color transformation and operation on the function

  20. Epigastric hernia contiguous with the laparoscopic port site after endoscopic robotic total prostatectomy.

    Science.gov (United States)

    Moriwaki, Yoshihiro; Otani, Jun; Okuda, Junzo; Maemoto, Ryo

    2018-03-23

    Both laparoscopic and endoscopic robotic surgery are widely accepted for many abdominal surgeries. However, the port site for the laparoscope cannot be easily sutured without defect, particularly in the cranial end; this can result in a port-site incisional hernia and trigger the progressive thinning and stretching of the linea alba, leading to epigastric hernia. In the present case, we encountered an epigastric hernia contiguous with an incisional scar at the port site from a previous endoscopic robotic total prostatectomy. Abdominal ultrasound and CT revealed that the width of the linea alba was 30-48 mm. Previous CT images prepared before endoscopic robotic prostatectomy had shown a thinning of the linea alba. We should be aware of the possibility of epigastric hernia after laparoscopic and endoscopic robotic surgery. In laparoscopic and endoscopic robotic surgery for a high-risk patient for epigastric hernia, we should consider additional sutures cranial to the port-site incision to prevent of an epigastric hernia. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  1. Out-of-plane displacement measurement by means of endoscopic moire interferometry

    International Nuclear Information System (INIS)

    Martinez-Celorio, R.A.; Dirckx, Joris J.J.; Marti-Lopez, Luis; Pena-Lecona, Francisco G.

    2004-01-01

    An endoscopic moire technique is proposed for measuring out-of-plane displacements in difficult to reach places. The Ronchi grid is projected onto the tilted object with one endoscope with a 0 deg. viewing angle. The object with the projected grid is imaged by a second endoscope with a 30 deg. viewing angle onto a charge-coupled device. The captured images are stored in a PC, and are used to calculate the out-of-plane displacement of the object with a phase stepping technique. A computer generated grating method is used instead of a physical phase-shift device in the optical setup. This allows designing a set of three reference grids with profiles closely similar to the projected grating. The technique is robust against problems associated with the temporal shifting method, such as nonlinear phase shift and noise. To test the feasibility of the technique the measurement of out-of-plane displacements of about 35 μm of a latex membrane under deformation is demonstrated. The advantages and disadvantages are discussed

  2. Computer Vision and Image Processing: A Paper Review

    Directory of Open Access Journals (Sweden)

    victor - wiley

    2018-02-01

    Full Text Available Computer vision has been studied from many persective. It expands from raw data recording into techniques and ideas combining digital image processing, pattern recognition, machine learning and computer graphics. The wide usage has attracted many scholars to integrate with many disciplines and fields. This paper provide a survey of the recent technologies and theoretical concept explaining the development of computer vision especially related to image processing using different areas of their field application. Computer vision helps scholars to analyze images and video to obtain necessary information,    understand information on events or descriptions, and scenic pattern. It used method of multi-range application domain with massive data analysis. This paper provides contribution of recent development on reviews related to computer vision, image processing, and their related studies. We categorized the computer vision mainstream into four group e.g., image processing, object recognition, and machine learning. We also provide brief explanation on the up-to-date information about the techniques and their performance.

  3. IDP: Image and data processing (software) in C++

    Energy Technology Data Exchange (ETDEWEB)

    Lehman, S. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    IDP++(Image and Data Processing in C++) is a complied, multidimensional, multi-data type, signal processing environment written in C++. It is being developed within the Radar Ocean Imaging group and is intended as a partial replacement for View. IDP++ takes advantage of the latest object-oriented compiler technology to provide `information hiding.` Users need only know C, not C++. Signals are treated like any other variable with a defined set of operators and functions in an intuitive manner. IDP++ is being designed for real-time environment where interpreted signal processing packages are less efficient.

  4. Sonographic and Endoscopic Findings in Cocaine-Induced Ischemic Colitis

    DEFF Research Database (Denmark)

    Leth, Thomas; Wilkens, Rune; Bonderup, Ole Kristian

    2015-01-01

    Cocaine-induced ischemic colitis is a recognized entity. The diagnosis is based on clinical and endoscopic findings. However, diagnostic imaging is helpful in the evaluation of abdominal symptoms and prior studies have suggested specific sonographic findings in ischemic colitis. We report...

  5. Photon technology. Laser process technology; Photon technology. Laser process gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    For developing laser process technology by interaction between substance and photon, the present state, system, R and D issues and proposal of such technology were summarized. Development of the photon technology aims at the modification of bonding conditions of substances by quantum energy of photon, and the new process technology for generating ultra- high temperature and pressure fields by concentrating photon on a minute region. Photon technology contributes to not only the conventional mechanical and thermal forming and removal machining but also function added machining (photon machining) in quantum level and new machining technology ranging from macro- to micro-machining, creating a new industrial field. This technology extends various fields from the basis of physics and chemistry to new bonding technology. Development of a compact high-quality high-power high-efficiency photon source, and advanced photon transmission technology are necessary. The basic explication of an unsolved physicochemical phenomenon related to photon and substance, and development of related application technologies are essential. 328 refs., 147 figs., 13 tabs.

  6. Technologies to support industrial processes

    International Nuclear Information System (INIS)

    Palazzi, G.; Savelli, D.

    1989-05-01

    Control and measuring techniques applied to industry have the common aim of increasing safety, reliability and plant availability. The industrial monitoring system needs a lot of sensors, whose signals, elaborated and interpreted, allow one to define the best working condition; moreover control instruments perform a diagnosis related to damages and breakages. The Experimental Engineering Division of ENEA's Thermal Reactor Department has developed sensors and measuring apparatus and has acquired advanced control techniques. All these systems, containing an original software, have been applied to industrial process problems and/or to experimental facilities both to increase reliability and to understand better process physics. Division activities are grouped in four sectors: non-destructive examinations (ultrasonic, eddy current, thermography, holographic interpherometry, penetrant liquids and magnetoscopy); innovative sensors (heated thermocouples, optical fiber sensors); advanced measuring systems (laser technology for fluidodynamic measures, nuclear radiation techniques, infrared measuring, mass spectrometer, hot-film anemometer, chromatographic apparatus); advanced technologies for diagnosis and signal analysis (digital image processing, statistical analysis). (author)

  7. Fundamental concepts of digital image processing

    Energy Technology Data Exchange (ETDEWEB)

    Twogood, R.E.

    1983-03-01

    The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under observation rather than days later.

  8. Fundamental Concepts of Digital Image Processing

    Science.gov (United States)

    Twogood, R. E.

    1983-03-01

    The field of a digital-image processing has experienced dramatic growth and increasingly widespread applicability in recent years. Fortunately, advances in computer technology have kept pace with the rapid growth in volume of image data in these and other applications. Digital image processing has become economical in many fields of research and in industrial and military applications. While each application has requirements unique from the others, all are concerned with faster, cheaper, more accurate, and more extensive computation. The trend is toward real-time and interactive operations, where the user of the system obtains preliminary results within a short enough time that the next decision can be made by the human processor without loss of concentration on the task at hand. An example of this is the obtaining of two-dimensional (2-D) computer-aided tomography (CAT) images. A medical decision might be made while the patient is still under observation rather than days later.

  9. Image processing of angiograms: A pilot study

    Science.gov (United States)

    Larsen, L. E.; Evans, R. A.; Roehm, J. O., Jr.

    1974-01-01

    The technology transfer application this report describes is the result of a pilot study of image-processing methods applied to the image enhancement, coding, and analysis of arteriograms. Angiography is a subspecialty of radiology that employs the introduction of media with high X-ray absorption into arteries in order to study vessel pathology as well as to infer disease of the organs supplied by the vessel in question.

  10. Concrete Crack Identification Using a UAV Incorporating Hybrid Image Processing.

    Science.gov (United States)

    Kim, Hyunjun; Lee, Junhwa; Ahn, Eunjong; Cho, Soojin; Shin, Myoungsu; Sim, Sung-Han

    2017-09-07

    Crack assessment is an essential process in the maintenance of concrete structures. In general, concrete cracks are inspected by manual visual observation of the surface, which is intrinsically subjective as it depends on the experience of inspectors. Further, it is time-consuming, expensive, and often unsafe when inaccessible structural members are to be assessed. Unmanned aerial vehicle (UAV) technologies combined with digital image processing have recently been applied to crack assessment to overcome the drawbacks of manual visual inspection. However, identification of crack information in terms of width and length has not been fully explored in the UAV-based applications, because of the absence of distance measurement and tailored image processing. This paper presents a crack identification strategy that combines hybrid image processing with UAV technology. Equipped with a camera, an ultrasonic displacement sensor, and a WiFi module, the system provides the image of cracks and the associated working distance from a target structure on demand. The obtained information is subsequently processed by hybrid image binarization to estimate the crack width accurately while minimizing the loss of the crack length information. The proposed system has shown to successfully measure cracks thicker than 0.1 mm with the maximum length estimation error of 7.3%.

  11. Successful Gastric Volvulus Reduction and Gastropexy Using a Dual Endoscope Technique

    Directory of Open Access Journals (Sweden)

    Laith H. Jamil

    2014-01-01

    Full Text Available Gastric volvulus is a life threatening condition characterized by an abnormal rotation of the stomach around an axis. Although the first line treatment of this disorder is surgical, we report here a case of gastric volvulus that was endoscopically managed using a novel strategy. An 83-year-old female with a history of pancreatic cancer status postpylorus-preserving Whipple procedure presented with a cecal volvulus requiring right hemicolectomy. Postoperative imaging included a CT scan and upper GI series that showed a gastric volvulus with the antrum located above the diaphragm. An upper endoscopy was advanced through the pylorus into the duodenum and left in this position to keep the stomach under the diaphragm. A second pediatric endoscope was advanced alongside and used to complete percutaneous endoscopic gastrostomy (PEG placement for anterior gastropexy. The patient’s volvulus resolved and there were no complications. From our review of the literature, the dual endoscopic technique employed here has not been previously described. Patients who are poor surgical candidates or those who do not require emergent surgery can possibly benefit the most from similar minimally invasive endoscopic procedures as described here.

  12. Virtual endoscopy combined with intraoperative neuronavigation for planning of endoscopic surgery in patients with occlusive hydrocephalus and intracranial cysts

    International Nuclear Information System (INIS)

    Krombach, G.A.; Haage, P.; Kilbinger, M.; Rohde, V.; Struffert, T.; Thron, A.

    2002-01-01

    We assessed the clinical value of MR ventriculoscopy (virtual endoscopy, VE) combined with image-guided frameless stereotaxy for endoscopic surgery of occlusive hydrocephalus and intracranial cysts. VE was obtained in 20 patients with hydrocephalus and three with intracranial cysts. All surgical operations were endoscopic. The path of the rigid endoscope to the target point was planned using neuronavigation. VE was carried out along the same trajectory retrospectively in 20 cases and prospectively in three. The results were analysed for demonstration of anatomical landmarks and structures at risk. VE was successful in all patients. Possible obstacles to endoscopic access to the lamina terminalis and the basal cisterns and structures at risk, such as the basilar artery, were clearly shown in relation to the direction of the endoscope. However, the floor of the third ventricle and septum pellucidum were not clearly seen and possible abnormalities could therefore not be appreciated. VE can provide realistic simulation of endoscopic third ventriculostomy and cystostomy. The appropriate trepanation point and trajectory of the endoscope can be assessed with regard to the size of the foramen of Monro and the position of vulnerable structures. This simulated trajectory can be adapted to the field of operation by image-guided neuronavigation. This regime may potentially reduce the risk of damage to intracranial structures. (orig.)

  13. Decontamination of minimally invasive surgical endoscopes and accessories.

    Science.gov (United States)

    Ayliffe, G

    2000-08-01

    (1) Infections following invasive endoscopy are rare and are usually of endogenous origin. Nevertheless, infections do occur due to inadequate cleaning and disinfection and the use of contaminated rinse water and processing equipment. (2) Rigid and flexible operative endoscopes and accessories should be thoroughly cleaned and preferably sterilized using properly validated processes. (3) Heat tolerant operative endoscopes and accessories should be sterilized using a vacuum assisted steam sterilizer. Use autoclavable instrument trays or containers to protect equipment during transit and processing. Small bench top sterilizers without vacuum assisted air removal are unsuitable for packaged and lumened devices. (4) Heat sensitive rigid and flexible endoscopes and accessories should preferably be sterilized using ethylene oxide, low temperature steam and formaldehyde (rigid only) or gas plasma (if appropriate). (5) If there are insufficient instruments or time to sterilize invasive endoscopes, or if no suitable method is available locally, they may be disinfected by immersion in 2% glutaraldehyde or a suitable alternative. An immersion time of at least 10 min should be adopted for glutaraldehyde. This is sufficient to inactivate most vegetative bacteria and viruses including HIV and hepatitis B virus (HBV). Longer contact times of 20 min or more may be necessary if a mycobacterial infection is known or suspected. At least 3 h immersion in glutaraldehyde is required to kill spores. (6) Glutaraldehyde is irritant and sensitizing to the skin, eyes and respiratory tract. Measures must be taken to ensure glutaraldehyde is used in a safe manner, i.e., total containment and/or extraction of harmful vapour and the provision of suitable personal protective equipment, i.e., gloves, apron and eye protection if splashing could occur. Health surveillance of staff is recommended and should include a pre-employment enquiry regarding asthma, skin and mucosal sensitivity problems and

  14. Current Innovations in Endoscopic Therapy for the Management of Colorectal Cancer: From Endoscopic Submucosal Dissection to Endoscopic Full-Thickness Resection

    Directory of Open Access Journals (Sweden)

    Shintaro Fujihara

    2014-01-01

    Full Text Available Endoscopic submucosal dissection (ESD is accepted as a minimally invasive treatment for colorectal cancer. However, due to technical difficulties and an increased rate of complications, ESD is not widely used in the colorectum. In some cases, endoscopic treatment alone is insufficient for disease control, and laparoscopic surgery is required. The combination of laparoscopic surgery and endoscopic resection represents a new frontier in cancer treatment. Recent developments in advanced polypectomy and minimally invasive surgical techniques will enable surgeons and endoscopists to challenge current practice in colorectal cancer treatment. Endoscopic full-thickness resection (EFTR of the colon offers the potential to decrease the postoperative morbidity and mortality associated with segmental colectomy while enhancing the diagnostic yield compared to current endoscopic techniques. However, closure is necessary after EFTR and natural transluminal endoscopic surgery (NOTES. Innovative methods and new devices for EFTR and suturing are being developed and may potentially change traditional paradigms to achieve minimally invasive surgery for colorectal cancer. The present paper aims to discuss the complementary role of ESD and the future development of EFTR. We focus on the possibility of achieving EFTR using the ESD method and closing devices.

  15. Image processing applications: From particle physics to society

    International Nuclear Information System (INIS)

    Sotiropoulou, C.-L.; Citraro, S.; Dell'Orso, M.; Luciano, P.; Gkaitatzis, S.; Giannetti, P.

    2017-01-01

    We present an embedded system for extremely efficient real-time pattern recognition execution, enabling technological advancements with both scientific and social impact. It is a compact, fast, low consumption processing unit (PU) based on a combination of Field Programmable Gate Arrays (FPGAs) and the full custom associative memory chip. The PU has been developed for real time tracking in particle physics experiments, but delivers flexible features for potential application in a wide range of fields. It has been proposed to be used in accelerated pattern matching execution for Magnetic Resonance Fingerprinting (biomedical applications), in real time detection of space debris trails in astronomical images (space applications) and in brain emulation for image processing (cognitive image processing). We illustrate the potentiality of the PU for the new applications.

  16. Experimental transapical endoscopic ventricular visualization and mitral repair.

    Science.gov (United States)

    Ruttkay, Tamas; Czesla, Markus; Nagy, Henrietta; Götte, Julia; Baksa, Gabor; Patonay, Lajos; Doll, Nicolas; Galajda, Zoltan

    2015-04-01

    An increasing number of experimental beating heart animal studies describe simple transapical mitral valve repairs based on the direct endoscopic visualization of the left ventricle. The aim of our human cadaveric study was to develop a method for more complex transapical endoscopic procedures by on-pump heart operations. After preparation of 20 human fresh cadavers, a standard left anterolateral minithoracotomy was performed in the fifth intercostal space and the pericardium was entered. A rigid 0 degree endoscope and the instruments were introduced through a silicon apical port. To restore the natural form of the left heart, CO2 was insufflated. To test the mitral valve competence, the left ventricle was pressure-injected with saline after each step. After transecting the chords of the A2 segment of the anterior mitral leaflet before the experimental mitral valve repair, the tendinous chord was replaced using an especially designed clip chord. The second part of the experiment consisted of a segmental excision of the P2 segment of the posterior mitral leaflet followed by a standard valvuloplasty and suture annuloplasty. With the help of the described transapical endoscopic mitral valve repair technique, we gained direct visual information of the coaptation line of the mitral leaflets as well as the anatomy and function of the subvalvular apparatus. Using intracardiac imaging, we could perform successful transapical complex mitral repair in each case. The minimally invasive transapical endoscopic method has the potential to offer advantages for on-pump mitral valve repair procedures even in complex mitral valve repair cases. Georg Thieme Verlag KG Stuttgart · New York.

  17. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    Science.gov (United States)

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  18. High Resolution Sub-MM Fiberoptic Endoscope Final Report CRADA No. TSB-1447-97

    Energy Technology Data Exchange (ETDEWEB)

    Stone, Gary F. [Univ. of California, Livermore, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, John [CML Fiberoptics, Inc., Auburn, NY (United States)

    2018-01-22

    At the time of the CRADA, LLNL needed to develop a sub-mm outer diameter fiberoptic endoscope with 25pm or better resolution at 3-lOmm working distance to support the Enhanced Surveillance Program (ESP) and the Core Surveillance Program for DOE. The commercially available systems did not meet the image resolution requirements and development work was needed to reach three goals. We also needed to perform preliminary investigations into the production of such an endoscope with a steerable-articulated distal end. The goal of such an endoscope was to allow for a 45 degree inspection cone including the lens field of view.

  19. Endoscopic third ventriculostomy

    Directory of Open Access Journals (Sweden)

    Yad Ram Yadav

    2012-01-01

    Full Text Available Endoscopic third ventriculostomy (ETV is considered as a treatment of choice for obstructive hydrocephalus. It is indicated in hydrocephalus secondary to congenital aqueductal stenosis, posterior third ventricle tumor, cerebellar infarct, Dandy-Walker malformation, vein of Galen aneurism, syringomyelia with or without Chiari malformation type I, intraventricular hematoma, post infective, normal pressure hydrocephalus, myelomeningocele, multiloculated hydrocephalus, encephalocele, posterior fossa tumor and craniosynostosis. It is also indicated in block shunt or slit ventricle syndrome. Proper Pre-operative imaging for detailed assessment of the posterior communicating arteries distance from mid line, presence or absence of Liliequist membrane or other membranes, located in the prepontine cistern is useful. Measurement of lumbar elastance and resistance can predict patency of cranial subarachnoid space and complex hydrocephalus, which decides an ultimate outcome. Water jet dissection is an effective technique of ETV in thick floor. Ultrasonic contact probe can be useful in selected patients. Intra-operative ventriculo-stomography could help in confirming the adequacy of endoscopic procedure, thereby facilitating the need for shunt. Intraoperative observations of the patent aqueduct and prepontine cistern scarring are predictors of the risk of ETV failure. Such patients may be considered for shunt surgery. Magnetic resonance ventriculography and cine phase contrast magnetic resonance imaging are effective in assessing subarachnoid space and stoma patency after ETV. Proper case selection, post-operative care including monitoring of ICP and need for external ventricular drain, repeated lumbar puncture and CSF drainage, Ommaya reservoir in selected patients could help to increase success rate and reduce complications. Most of the complications develop in an early post-operative, but fatal complications can develop late which indicate an importance of

  20. Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project

    CERN Document Server

    Frisch, Benjamin

    2013-01-01

    The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-Of-Flight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the body in coincidence with the head. The high level of miniaturization and integration creates challenges in fields such as scintillating crystals, ultra-fast photo-detection, highly integrated electronics, system integration and image reconstruction. Amongst the developments, fast scintillators as well as fast and compact digital SiPMs with single SPAD readout are used to obtain the best coincidence time resolution (CTR). Highly integrated ASICs and DAQ electronics contribute to the timing performances of EndoTOFPET. In view of the targeted resolution of around 1 mm in the reconstructed image, we present a prototype dete...

  1. A standardised protocol for texture feature analysis of endoscopic images in gynaecological cancer

    Directory of Open Access Journals (Sweden)

    Pattichis Marios S

    2007-11-01

    Full Text Available Abstract Background In the development of tissue classification methods, classifiers rely on significant differences between texture features extracted from normal and abnormal regions. Yet, significant differences can arise due to variations in the image acquisition method. For endoscopic imaging of the endometrium, we propose a standardized image acquisition protocol to eliminate significant statistical differences due to variations in: (i the distance from the tissue (panoramic vs close up, (ii difference in viewing angles and (iii color correction. Methods We investigate texture feature variability for a variety of targets encountered in clinical endoscopy. All images were captured at clinically optimum illumination and focus using 720 × 576 pixels and 24 bits color for: (i a variety of testing targets from a color palette with a known color distribution, (ii different viewing angles, (iv two different distances from a calf endometrial and from a chicken cavity. Also, human images from the endometrium were captured and analysed. For texture feature analysis, three different sets were considered: (i Statistical Features (SF, (ii Spatial Gray Level Dependence Matrices (SGLDM, and (iii Gray Level Difference Statistics (GLDS. All images were gamma corrected and the extracted texture feature values were compared against the texture feature values extracted from the uncorrected images. Statistical tests were applied to compare images from different viewing conditions so as to determine any significant differences. Results For the proposed acquisition procedure, results indicate that there is no significant difference in texture features between the panoramic and close up views and between angles. For a calibrated target image, gamma correction provided an acquired image that was a significantly better approximation to the original target image. In turn, this implies that the texture features extracted from the corrected images provided for better

  2. Endoscopic submucosal dissection

    DEFF Research Database (Denmark)

    Pimentel-Nunes, Pedro; Dinis-Ribeiro, Mário; Ponchon, Thierry

    2015-01-01

    evidence). 2 ESGE recommends endoscopic resection with a curative intent for visible lesions in Barrett's esophagus (strong recommendation, moderate quality evidence). ESD has not been shown to be superior to EMR for excision of mucosal cancer, and for that reason EMR should be preferred. ESD may...... RECOMMENDATIONS: 1 ESGE recommends endoscopic en bloc resection for superficial esophageal squamous cell cancers (SCCs), excluding those with obvious submucosal involvement (strong recommendation, moderate quality evidence). Endoscopic mucosal resection (EMR) may be considered in such lesions when...

  3. Implementation of remote video auditing with feedback and compliance for manual-cleaning protocols of endoscopic retrograde cholangiopancreatography endoscopes.

    Science.gov (United States)

    Armellino, Donna; Cifu, Kelly; Wallace, Maureen; Johnson, Sherly; DiCapua, John; Dowling, Oonagh; Jacobs, Mitchel; Browning, Susan

    2018-05-01

    A pilot initiative to assess the use of remote video auditing in monitoring compliance with manual-cleaning protocols for endoscopic retrograde cholangiopancreatography (ERCP) endoscopes was performed. Compliance with manual-cleaning steps following the initiation of feedback was measured. A video feed of the ERCP reprocessing room was provided to remote auditors who scored items of an ERCP endoscope manual-cleaning checklist. Compliance feedback was provided in the form of reports and reeducation. Outcomes were reported as checklist compliance. The use of remote video auditing to document manual processing is a feasible approach and feedback and reeducation increased manual-cleaning compliance from 53.1% (95% confidence interval, 34.7-71.6) to 98.9% (95.0% confidence interval, 98.1-99.6). Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Modified endoscopic medial maxillectomy for zygomatic implant salvage.

    Science.gov (United States)

    Schwartz, Joseph S; Tajudeen, Bobby A; Adappa, Nithin D; Palmer, James N

    2016-01-01

    Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant.

  5. Gastric schwannomas: radiological features with endoscopic and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Hong, H.S. [Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seodaemoon-gu, Seoul (Korea, Republic of); Ha, H.K. [Department of Radiology, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of)], E-mail: hkha@amc.seoul.kr; Won, H.J.; Byun, J.H.; Shin, Y.M.; Kim, A.Y.; Kim, P.N.; Lee, M.-G. [Department of Radiology, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of); Lee, G.H. [Internal Medicine, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of); Kim, M.J. [Pathology, Asan Medical Center, University of Ulsan College of Medicine, Songpa-gu, Seoul (Korea, Republic of)

    2008-05-15

    Aim: To describe the radiological, endoscopic, and pathological findings of gastric schwannomas in 16 patients. Materials and methods: The radiological, endoscopic, and pathological findings of 16 surgically proven cases of gastric schwannoma were retrospectively reviewed. All patients underwent computed tomography (CT) and four patients were evaluated with upper gastrointestinal series. Two radiologists reviewed the CT and upper gastrointestinal series images by consensus with regard to tumour size, contour, margin, and growth pattern, the presence or absence of ulcer, cystic change, and the CT enhancement pattern. Endoscopy was performed in eight of these 16 patients. Six patients underwent endoscopic ultrasonography. Pathological specimens were obtained from and reviewed in all 16 patients. Immunohistochemistry was performed for c-kit, CD34, smooth muscle actin, and S-100 protein. Results: On radiographic examination, gastric schwannomas appeared as submucosal tumours with the CT features of well-demarcated, homogeneous, and uncommonly ulcerated masses. Endoscopy with endoscopic ultrasonography demonstrated homogeneous, submucosal masses contiguous with the muscularis propria in all six examined cases. On pathological examination, gastric schwannomas appeared as well-circumscribed and homogeneous tumours in the muscularis propria and consisted microscopically of interlacing bundles of spindle cells. Strong positivity for S-100 protein was demonstrated in all 16 cases on immunohistochemistry. Conclusion: Gastric schwannomas appear as submucosal tumours of the stomach and have well-demarcated and homogeneous features on CT, endoscopic ultrasonography, and gross pathology. Immunohistochemistry consistently reveals positivity for S-100 protein in the tumours.

  6. Gastric schwannomas: radiological features with endoscopic and pathological correlation

    International Nuclear Information System (INIS)

    Hong, H.S.; Ha, H.K.; Won, H.J.; Byun, J.H.; Shin, Y.M.; Kim, A.Y.; Kim, P.N.; Lee, M.-G.; Lee, G.H.; Kim, M.J.

    2008-01-01

    Aim: To describe the radiological, endoscopic, and pathological findings of gastric schwannomas in 16 patients. Materials and methods: The radiological, endoscopic, and pathological findings of 16 surgically proven cases of gastric schwannoma were retrospectively reviewed. All patients underwent computed tomography (CT) and four patients were evaluated with upper gastrointestinal series. Two radiologists reviewed the CT and upper gastrointestinal series images by consensus with regard to tumour size, contour, margin, and growth pattern, the presence or absence of ulcer, cystic change, and the CT enhancement pattern. Endoscopy was performed in eight of these 16 patients. Six patients underwent endoscopic ultrasonography. Pathological specimens were obtained from and reviewed in all 16 patients. Immunohistochemistry was performed for c-kit, CD34, smooth muscle actin, and S-100 protein. Results: On radiographic examination, gastric schwannomas appeared as submucosal tumours with the CT features of well-demarcated, homogeneous, and uncommonly ulcerated masses. Endoscopy with endoscopic ultrasonography demonstrated homogeneous, submucosal masses contiguous with the muscularis propria in all six examined cases. On pathological examination, gastric schwannomas appeared as well-circumscribed and homogeneous tumours in the muscularis propria and consisted microscopically of interlacing bundles of spindle cells. Strong positivity for S-100 protein was demonstrated in all 16 cases on immunohistochemistry. Conclusion: Gastric schwannomas appear as submucosal tumours of the stomach and have well-demarcated and homogeneous features on CT, endoscopic ultrasonography, and gross pathology. Immunohistochemistry consistently reveals positivity for S-100 protein in the tumours

  7. Endoscopic management of biliary injuries and leaks

    Directory of Open Access Journals (Sweden)

    T S Chandrasekar

    2012-01-01

    Full Text Available Bile duct injuries and subsequent leaks can occur following laparoscopic and open cholecystectomies and also during other hepatobiliary surgeries. Various patient related and technical factors are implicated in the causation of biliary injuries. Over a period of twenty five years managing such patients of biliary injuries our team has found a practical approach to assess the cause of biliary injuries based on the symptoms, clinical examination and imaging. Bismuth classification is helpful in most of the cases. Immediate referral to a centre experienced in the management of bile duct injury and timely intervention is associated with improved outcomes. Resuscitation, correcting dyselectrolytemia, aspiration of undrained biloma and antibiotics take the priority in the management. The goal is to restore the bile conduit, and to prevent short and longterm complications such as biliary fistula, intra-abdominal abscess, biliary stricture, recurrent cholangitis and secondary biliary cirrhosis. Endoscopic therapy by reducing the transpapillary pressure gradient helps in reducing the leak. Endoscopic therapy with biliary sphincterotomy alone or with additional placement of a biliary stent/ nasobiliary drainage is advocated. In our tertiary care referral unit, we found endoscopic interventions are useful in situations where there is leak with associated CBD calculus or a foreign body, peripheral bile duct injury, cystic duct stump leak and partial bile duct injury with leak/ narrowing of the lumen. Endotherapy is not useful in case of complete transection (total cut off and complete stricture involving common hepatic or common bile ducts. In conclusion, endoscopic treatment can be considered a highly effective therapy and should be the first-line therapy in such patients. Though less successful, an endoscopic attempt is warranted in patients suffering from central bile duct leakages failing which surgical management is recommended.

  8. Endoscopic middle ear exploration in pediatric patients with conductive hearing loss.

    Science.gov (United States)

    Carter, John M; Hoff, Stephen R

    2017-05-01

    To describe our indications, findings, and outcomes for transcanal endoscopic middle ear exploration in pediatric patients with conductive hearing loss of unknown etiology, without effusions. Prospective case series for all pediatric patients undergoing totally endoscopic transcanal middle ear exploration between April 2012 and October 2015 at a pediatric tertiary care referral hospital. Demographic data, operative findings, and hearing results were reviewed. 21 cases were performed in 20 ears (1 revision). Average age at surgery was 7.98 years and average follow up was 2.1 years. Middle ear pathology identified on CT imaging was confirmed in 55% of cases while identified in 45% of cases where pre-operative imaging was non-diagnostic. 6/20 patients (30%) had an ossicular deformity. 8/20(40%) had bony ossicular fixation. 5/20(25%) had ossicular discontinuity. 2/20(10%) had facial nerve dehiscence impinging on the stapes. 15% had adhesive myringosclerosis or severe granulation causing hearing loss. Prosthetic ossiculoplasty was done in 7/21 (33.3%) of the cases, with 1 TORP, 3 PORPs, and 3 IS joint replacements. Imaging was predictive of intra-operative findings in 13/20 cases (55%). Trainees assisted in 16/21(76%) of cases. The average improvement of PTA was 11.65 dB (range -10 to 36.25), and the average ABG improved 10.19 (range -11.25 to 28.75). There were no perioperative complications or adverse events. The endoscopic transcanal approach for middle ear exploration offers excellent visualization and is one of the best applications for the endoscopes in pediatric otology cases. This is particularly helpful for "unexplained" conductive hearing loss where ossicular deformity/fixation/discontinuity is suspected. The etiology of the conductive hearing loss was definitively found in 100% of cases, and can be repaired in the same sitting when applicable. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. DAE-BRNS workshop on applications of image processing in plant sciences and agriculture: lecture notes

    International Nuclear Information System (INIS)

    1998-10-01

    Images form important data and information in biological sciences. Until recently photography was the only method to reproduce and report such data. It is difficult to quantify or treat the photographic data mathematically. Digital image processing and image analysis technology based on recent advances in microelectronics and computers circumvents these problems associated with traditional photography. WIPSA (Workshop on Applications of Image Processing in Plant Sciences and Agriculture) will feature topics on the basic aspects of computers, imaging hardware and software as well advanced aspects such as colour image processing, high performance computing, neural networks, 3-D imaging and virtual reality. Imaging done using ultrasound, thermal, x-rays and γ rays, neutron radiography and the film-less phosphor-imager technology will also be discussed. Additionally application of image processing/analysis in plant sciences, medicine and satellite imagery are discussed. Papers relevant to INIS are indexed separately

  10. Endoscopic management of colorectal adenomas.

    Science.gov (United States)

    Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur

    2017-01-01

    Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.

  11. Sensitivity of endoscopic ultrasound, multidetector computed tomography, and magnetic resonance cholangiopancreatography in the diagnosis of pancreas divisum: a tertiary center experience.

    Science.gov (United States)

    Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R

    2013-04-01

    There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.

  12. Real-time particle image velocimetry based on FPGA technology

    International Nuclear Information System (INIS)

    Iriarte Munoz, Jose Miguel

    2008-01-01

    Particle image velocimetry (PIV), based on laser sheet, is a method for image processing and calculation of distributed velocity fields.It is well established as a fluid dynamics measurement tool, being applied to liquid, gases and multiphase flows.Images of particles are processed by means of computationally demanding algorithms, what makes its real-time implementation difficult.The most probable displacements are found applying two dimensional cross-correlation function. In this work, we detail how it is possible to achieve real-time visualization of PIV method by designing an adaptive embedded architecture based on FPGA technology.We show first results of a physical field of velocity calculated by this platform system in a real-time approach. [es

  13. Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures.

    Science.gov (United States)

    Buss, A J; Been, M H; Borgers, R P; Stokroos, I; Melchers, W J; Peters, F T; Limburg, A J; Degener, J E

    2008-04-01

    Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to trace disinfection problems to individual endoscopes or washer-disinfectors. Our surveillance protocol included anterograde and retrograde sampling, a decision algorithm, genetic fingerprinting, and scanning electron microscopy. Over a period of 29 months we found an increasing number of patient-ready endoscopes testing positive for Candida species other than albicans, especially C. parapsilosis. These yeasts were also isolated from the washer-disinfectors. The number of positive tests for Candida species varied from 1 out of 21 to 14 out of 27 samples from nine frequently used endoscopes. The number of colony-forming units per milliliter ranged from 1 - 10 to 3000 for endoscopes and 0.002 to 0.06 for the washer disinfectors. DNA fingerprinting was not able to discriminate different strains within C. parapsilosis. Our protocol was able to detect a structural problem in the endoscope disinfection process. Retrograde sampling was crucial for this purpose, because it has much higher sensitivity than anterograde sampling. Endoscopes with damaged working channels are probably the source of the contamination problem with Candida species.

  14. A Haptic Guided Robotic System for Endoscope Positioning and Holding.

    Science.gov (United States)

    Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk

    2015-01-01

    To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.

  15. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Learning endoscopic resection in the esophagus

    NARCIS (Netherlands)

    van Vilsteren, Frederike G. I.; Pouw, Roos E.; Herrero, Lorenza Alvarez; Bisschops, Raf; Houben, Martin; Peters, Frans T. M.; Schenk, B. E.; Weusten, Bas L. A. M.; Schoon, Erik J.; Bergman, Jacques J. G. H. M.

    Background: Endoscopic resection is the cornerstone of endoscopic management of esophageal early neoplasia. However, endoscopic resection is a complex technique requiring knowledge and expertise. Our aims were to identify the most important learning points in performing endoscopic resection in a

  17. Classification of atrophic mucosal patterns on Blue LASER Imaging for endoscopic diagnosis of Helicobacter pylori-related gastritis: A retrospective, observational study.

    Science.gov (United States)

    Nishikawa, Yoshiyuki; Ikeda, Yoshio; Murakami, Hidehiro; Hori, Shin-Ichiro; Hino, Kaori; Sasaki, Chise; Nishikawa, Megumi

    2018-01-01

    Atrophic gastritis can be classified according to characteristic mucosal patterns observed by Blue LASER Imaging (BLI) in a medium-range to distant view. To facilitate the endoscopic diagnosis of Helicobacter pylori (HP)-related gastritis, we investigated whether atrophic mucosal patterns correlated with HP infection based on the image interpretations of three endoscopists blinded to clinical features. This study included 441 patients diagnosed as having atrophic gastritis by upper gastrointestinal endoscopy at Nishikawa Gastrointestinal Clinic between April 1, 2015 and March 31, 2016. The presence/absence of HP infection was not taken into consideration. Endoscopy was performed using a Fujifilm EG-L580NW scope. Atrophic mucosal patterns observed by BLI were classified into Spotty, Cracked and Mottled. Image interpretation results were that 89, 122 and 228 patients had the Spotty, Cracked and Mottled patterns, respectively, and 2 patients an undetermined pattern. Further analyses were performed on 439 patients, excluding the 2 with undetermined patterns. The numbers of patients testing negative/positive for HP infection in the Spotty, Cracked and Mottled pattern groups were 12/77, 105/17, and 138/90, respectively. The specificity, positive predictive value and positive likelihood ratio for endoscopic diagnosis with positive HP infection based on the Spotty pattern were 95.3%, 86.5% and 8.9, respectively. In all patients with the Spotty pattern before HP eradication, the Cracked pattern was observed on subsequent post-eradication endoscopy. The Spotty pattern may represent the presence of HP infection, the Cracked pattern, a post-inflammatory change as seen after HP eradication, and the Mottled pattern, intestinal metaplasia.

  18. The utility of high-resolution intraoperative MRI in endoscopic transsphenoidal surgery for pituitary macroadenomas: early experience in the Advanced Multimodality Image Guided Operating suite

    Science.gov (United States)

    Zaidi, Hasan A.; De Los Reyes, Kenneth; Barkhoudarian, Garni; Litvack, Zachary N.; Bi, Wenya Linda; Rincon-Torroella, Jordina; Mukundan, Srinivasan; Dunn, Ian F.; Laws, Edward R.

    2016-01-01

    Objective Endoscopic skull base surgery has become increasingly popular among the skull base surgery community, with improved illumination and angled visualization potentially improving tumor resection rates. Intraoperative MRI (iMRI) is used to detect residual disease during the course of the resection. This study is an investigation of the utility of 3-T iMRI in combination with transnasal endoscopy with regard to gross-total resection (GTR) of pituitary macroadenomas. Methods The authors retrospectively reviewed all endoscopic transsphenoidal operations performed in the Advanced Multimodality Image Guided Operating (AMIGO) suite from November 2011 to December 2014. Inclusion criteria were patients harboring presumed pituitary macroadenomas with optic nerve or chiasmal compression and visual loss, operated on by a single surgeon. Results Of the 27 patients who underwent transsphenoidal resection in the AMIGO suite, 20 patients met the inclusion criteria. The endoscope alone, without the use of iMRI, would have correctly predicted 13 (65%) of 20 cases. Gross-total resection was achieved in 12 patients (60%) prior to MRI. Intraoperative MRI helped convert 1 STR and 4 NTRs to GTRs, increasing the number of GTRs from 12 (60%) to 16 (80%). Conclusions Despite advances in visualization provided by the endoscope, the incidence of residual disease can potentially place the patient at risk for additional surgery. The authors found that iMRI can be useful in detecting unexpected residual tumor. The cost-effectiveness of this tool is yet to be determined. PMID:26926058

  19. Transaxillary Endoscopic Breast Augmentation

    Directory of Open Access Journals (Sweden)

    Hyung-Bo Sim

    2014-09-01

    Full Text Available The axillary technique is the most popular approach to breast augmentation among Korean women. Transaxillary breast augmentation is now conducted with sharp electrocautery dissection under direct endoscopic vision throughout the entire process. The aims of this method are clear: both a bloodless pocket and a sharp non-traumatic dissection. Round textured or anatomical cohesive gel implants have been used to make predictable well-defined inframammary creases because textured surface implants demonstrated a better stability attributable to tissue adherence compared with smooth surface implants. The axillary endoscopic technique has greatly evolved, and now the surgical results are comparable to those with the inframammary approach. The author feels that this technique is an excellent choice for young patients with an indistinct or absent inframammary fold, who do not want a scar in the aesthetic unit of their chest.

  20. Simulation, image reconstruction and SiPM characterisation for a novel endoscopic positron emission tomography detector

    Energy Technology Data Exchange (ETDEWEB)

    Zvolsky, Milan

    2017-12-15

    In the scope of the EndoTOFPET-US project, a novel multimodal device for ultrasound (US) endoscopy and positron emission tomography (PET) is being developed. The project aims at detecting and quantifying morphologic and functional biomarkers and developing new biomarkers for pancreas and prostate oncology. The detector system comprises a small detector probe mounted on an ultrasound endoscope and an external detector plate. The detection of the gamma rays is realised by scintillator crystals with Silicon Photomultiplier (SiPM) read-out. For the characterisation of over 4000 SiPMs for the external plate, an automatised measurement and data analysis procedure is established. The key properties of the SiPMs like breakdown voltage and dark count rate (DCR) are extracted. This knowledge is needed both as a quality assurance as well as for the calibration of the detector. The spread between minimum and maximum breakdown voltage within a SiPM array of 4 x 4 is at maximum 0.43 V with a mean of 0.15 V and an RMS of 0.06 V. This assures the optimal biasing of each SiPM at its individual operating voltage. The mean DCR amounts to 1.49 MHz with an RMS of 0.54 MHz and is thus well below the acceptable threshold of 3 MHz. Two spare modules from the external plate are re-measured and analysed several years after the module assembly, revealing a potential alteration of the SiPM noise properties over time. For the characterisation of SiPMs from different vendors, a software framework for the automatic extraction of performance parameters from pulseheight spectra, including a t of the entire spectrum, is developed and tested. In order to facilitate the modelling of the response of the EndoTOFPET-US detector, a framework is developed which is built around the Geant4-based simulation toolkit GAMOS, to simulate and reconstruct realistic imaging scenarios with this asymmetric PET detector. The simulation studies are used to compare different possible detector designs, guide the

  1. Simulation, image reconstruction and SiPM characterisation for a novel endoscopic positron emission tomography detector

    International Nuclear Information System (INIS)

    Zvolsky, Milan

    2017-12-01

    In the scope of the EndoTOFPET-US project, a novel multimodal device for ultrasound (US) endoscopy and positron emission tomography (PET) is being developed. The project aims at detecting and quantifying morphologic and functional biomarkers and developing new biomarkers for pancreas and prostate oncology. The detector system comprises a small detector probe mounted on an ultrasound endoscope and an external detector plate. The detection of the gamma rays is realised by scintillator crystals with Silicon Photomultiplier (SiPM) read-out. For the characterisation of over 4000 SiPMs for the external plate, an automatised measurement and data analysis procedure is established. The key properties of the SiPMs like breakdown voltage and dark count rate (DCR) are extracted. This knowledge is needed both as a quality assurance as well as for the calibration of the detector. The spread between minimum and maximum breakdown voltage within a SiPM array of 4 x 4 is at maximum 0.43 V with a mean of 0.15 V and an RMS of 0.06 V. This assures the optimal biasing of each SiPM at its individual operating voltage. The mean DCR amounts to 1.49 MHz with an RMS of 0.54 MHz and is thus well below the acceptable threshold of 3 MHz. Two spare modules from the external plate are re-measured and analysed several years after the module assembly, revealing a potential alteration of the SiPM noise properties over time. For the characterisation of SiPMs from different vendors, a software framework for the automatic extraction of performance parameters from pulseheight spectra, including a t of the entire spectrum, is developed and tested. In order to facilitate the modelling of the response of the EndoTOFPET-US detector, a framework is developed which is built around the Geant4-based simulation toolkit GAMOS, to simulate and reconstruct realistic imaging scenarios with this asymmetric PET detector. The simulation studies are used to compare different possible detector designs, guide the

  2. Endoscopic visualization of luminal organ and great vessels with three dimensional CT scanner

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Okumura, Toshiyuki; Amemiya, Ryuta; Hasegawa, Hiroshi

    1992-01-01

    Thirty cases examined by three dimensional CT scanner (3DCT) are reported. The observation of inner view using 3DCT were performed in 12 large vessels with vascular disorder, 10 pulmonary bronchi with lung cancer and 8 common bile ducts involved obstructive disease. In order to visualize interface of the lumen, a new software, which was developed by HITACHI MEDICO Inc., was used. In all cases but one the inner view of the luminal organ was clearly demonstrated as 3D images and it was possible to judge some changes of luminal interface involved by the diseases. The 3DCT endoscopic image might be useful as a new endoscopic technique without fiberscopy. (author)

  3. Recent applications of Chemical Imaging to pharmaceutical process monitoring and quality control.

    Science.gov (United States)

    Gowen, A A; O'Donnell, C P; Cullen, P J; Bell, S E J

    2008-05-01

    Chemical Imaging (CI) is an emerging platform technology that integrates conventional imaging and spectroscopy to attain both spatial and spectral information from an object. Vibrational spectroscopic methods, such as Near Infrared (NIR) and Raman spectroscopy, combined with imaging are particularly useful for analysis of biological/pharmaceutical forms. The rapid, non-destructive and non-invasive features of CI mark its potential suitability as a process analytical tool for the pharmaceutical industry, for both process monitoring and quality control in the many stages of drug production. This paper provides an overview of CI principles, instrumentation and analysis. Recent applications of Raman and NIR-CI to pharmaceutical quality and process control are presented; challenges facing CI implementation and likely future developments in the technology are also discussed.

  4. [Application of image recognition technology in census of national traditional Chinese medicine resources].

    Science.gov (United States)

    Zhang, Xiao-Bo; Ge, Xiao-Guang; Jin, Yan; Shi, Ting-Ting; Wang, Hui; Li, Meng; Jing, Zhi-Xian; Guo, Lan-Ping; Huang, Lu-Qi

    2017-11-01

    With the development of computer and image processing technology, image recognition technology has been applied to the national medicine resources census work at all stages.Among them: ①In the preparatory work, in order to establish a unified library of traditional Chinese medicine resources, using text recognition technology based on paper materials, be the assistant in the digitalization of various categories related to Chinese medicine resources; to determine the representative area and plots of the survey from each census team, based on the satellite remote sensing image and vegetation map and other basic data, using remote sensing image classification and other technical methods to assist in determining the key investigation area. ②In the process of field investigation, to obtain the planting area of Chinese herbal medicine was accurately, we use the decision tree model, spectral feature and object-oriented method were used to assist the regional identification and area estimation of Chinese medicinal materials.③In the process of finishing in the industry, in order to be able to relatively accurately determine the type of Chinese medicine resources in the region, based on the individual photos of the plant, the specimens and the name of the use of image recognition techniques, to assist the statistical summary of the types of traditional Chinese medicine resources. ④In the application of the results of transformation, based on the pharmaceutical resources and individual samples of medicinal herbs, the development of Chinese medicine resources to identify APP and authentic herbs 3D display system, assisted the identification of Chinese medicine resources and herbs identification characteristics. The introduction of image recognition technology in the census of Chinese medicine resources, assisting census personnel to carry out related work, not only can reduce the workload of the artificial, improve work efficiency, but also improve the census results

  5. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  6. New real-time image processing system for IRFPA

    Institute of Scientific and Technical Information of China (English)

    WANG Bing-jian; LIU Shang-qian; CHENG Yu-bao

    2006-01-01

    Influenced by detectors' material,manufacturing technology etc,every detector in infrared focal plane array (IRFPA) will output different voltages even if their input radiation flux is the same.And this is called non-uniformity of IRFPA.At the same time,the high background temperature,low temperature difference between targets and background and the low responsivity of IRFPA result in low contrast of infrared images.So non-uniformity correction and image enhancement are important techniques for IRFPA imaging system.This paper proposes a new real-time infrared image processing system based on Field Programmable Gate Array(FPGA).The system implements non-uniformity correction,image enhancement and video synthesization etc.By using parallel architecture and pipeline technique,the system processing speed is as high as 50Mx12bits per second.It is appropriate greatly to a large IRFPA and a high frame frequency IRFPA imaging system.The system is miniatured in one FPGA.

  7. Dosimetry in endoscopic examinations

    International Nuclear Information System (INIS)

    Aldred, Martha Aurelia; Paes, Walter Siqueira; Fausto, Agnes M.F.; Nucci, Jose Roberto; Yoshimura, Elisabeth Mateus; Okuno, Emico; Maruta, Luis Massuo

    1996-01-01

    Equivalent and effective doses in occupational exposures are evaluated considering that some specific endoscopic examinations, radiographic and fluoroscopic images of patients are taken with the medical staff near to the radiation field. Examinations are simulated using an anthropomorphic phantom as a member of the medical staff. Thermoluminescent dosemeters are attached in several positions of the phantom in order to determine some organ doses. From the comparison between the doses experimentally determined and the International and the Brazilian recommended occupational dose limits, the maximum number of examination that any member of the staff can perform was calculated

  8. [Virtual bronchoscopy: the correlation between endoscopic simulation and bronchoscopic findings].

    Science.gov (United States)

    Salvolini, L; Gasparini, S; Baldelli, S; Bichi Secchi, E; Amici, F

    1997-11-01

    We carried out a preliminary clinical validation of 3D spiral CT virtual endoscopic reconstructions of the tracheobronchial tree, by comparing virtual bronchoscopic images with actual endoscopic findings. Twenty-two patients with tracheobronchial disease suspected at preliminary clinical, cytopathological and plain chest film findings were submitted to spiral CT of the chest and bronchoscopy. CT was repeated after endobronchial therapy in 2 cases. Virtual endoscopic shaded-surface-display views of the tracheobronchial tree were reconstructed from reformatted CT data with an Advantage Navigator software. Virtual bronchoscopic images were preliminarily evaluated with a semi-quantitative quality score (excellent/good/fair/poor). The depiction of consecutive airway branches was then considered. Virtual bronchoscopies were finally submitted to double-blind comparison with actual endoscopies. Virtual image quality was considered excellent in 8 cases, good in 14 and fair in 2. Virtual exploration was stopped at the lobar bronchi in one case only; the origin of segmental bronchi was depicted in 23 cases and that of some subsegmental branches in 2 cases. Agreement between actual and virtual bronchoscopic findings was good in all cases but 3 where it was nevertheless considered satisfactory. The yield of clinically useful information differed in 8/24 cases: virtual reconstructions provided more information than bronchoscopy in 5 cases and vice versa in 3. Virtual reconstructions are limited in that the procedure is long and difficult and needing a strictly standardized threshold value not to alter virtual findings. Moreover, the reconstructed surface lacks transparency, there is the partial volume effect and the branches < or = 4 pixels phi and/or meandering ones are difficult to explore. Our preliminary data are encouraging. Segmental bronchi were depicted in nearly all cases, except for the branches involved by disease. Obstructing lesions could be bypassed in some cases

  9. Endoscopic submucosal dissection for locally recurrent colorectal lesions after previous endoscopic mucosal resection.

    Science.gov (United States)

    Zhou, Pinghong; Yao, Liqing; Qin, Xinyu; Xu, Meidong; Zhong, Yunshi; Chen, Weifeng

    2009-02-01

    The objective of this study was to determine the efficacy and safety of endoscopic submucosal dissection for locally recurrent colorectal cancer after previous endoscopic mucosal resection. A total of 16 patients with locally recurrent colorectal lesions were enrolled. A needle knife, an insulated-tip knife and a hook knife were used to resect the lesion along the submucosa. The rate of the curative resection, procedure time, and incidence of complications were evaluated. Of 16 lesions, 15 were completely resected with endoscopic submucosal dissection, yielding an en bloc resection rate of 93.8 percent. Histologic examination confirmed that lateral and basal margins were cancer-free in 14 patients (87.5 percent). The average procedure time was 87.2 +/- 60.7 minutes. None of the patients had immediate or delayed bleeding during or after endoscopic submucosal dissection. Perforation in one patient (6.3 percent) was the only complication and was managed conservatively. The mean follow-up period was 15.5 +/- 6.8 months; none of the patients experienced lesion residue or recurrence. Endoscopic submucosal dissection appears to be effective for locally recurrent colorectal cancer after previous endoscopic mucosal resection, making it possible to resect whole lesions and provide precise histologic information.

  10. Endoscopic case

    Directory of Open Access Journals (Sweden)

    Fernando Pereira

    2017-01-01

    Full Text Available We present the case of a ten-year-old female patient referred to Gastroenterolgy consultation for abdominal pain and cramping, usually worse after eating, recurring diarrhoea, hypochromic and microcytic anaemia with low serum iron and ferritin levels. Moderate to severe Crohn’s disease of the terminal ileum e right colon (L3 was diagnosed, based on endoscopic image and biopsy. The patient was treated with prednisone and azathioprine, but after one year of treatment she was steroids dependent and treatment was switched to infliximab. One year after beginning this treatment, the patient achieved remission (clinical and laboratorial parameters. A control colonoscopy showed mucosal healing with scars and deformation with stenosis of ileocecal valve (Figures 1-2. Surgical intervention will be probably necessary in near future.

  11. Preliminary experience with 4K ultra-high definition endoscope: analysis of pros and cons in skull base surgery.

    Science.gov (United States)

    Rigante, M; La Rocca, G; Lauretti, L; D'Alessandris, G Q; Mangiola, A; Anile, C; Olivi, A; Paludetti, G

    2017-06-01

    During the last two decades endoscopic skull base surgery observed a continuous technical and technological development 3D endoscopy and ultra High Definition (HD) endoscopy have provided great advances in terms of visualisation and spatial resolution. Ultra-high definition (UHD) 4K systems, recently introduced in the clinical practice, will shape next steps forward especially in skull base surgery field. Patients were operated on through transnasal transsphenoidal endoscopic approaches performed using Olympus NBI 4K UHD endoscope with a 4 mm 0° Ultra Telescope, 300 W xenon lamp (CLV-S400) predisposed for narrow band imaging (NBI) technology connected through a camera head to a high-quality control unit (OTV-S400 - VISERA 4K UHD) (Olympus Corporation, Tokyo, Japan). Two screens are used, one 31" Monitor - (LMD-X310S) and one main ultra-HD 55" screen optimised for UHD image reproduction (LMD-X550S). In selected cases, we used a navigation system (Stealthstation S7, Medtronic, Minneapolis, MN, US). We evaluated 22 pituitary adenomas (86.3% macroadenomas; 13.7% microadenomas). 50% were not functional (NF), 22.8% GH, 18.2% ACTH, 9% PRL-secreting. Three of 22 were recurrences. In 91% of cases we achieved total removal, while in 9% near total resection. A mean follow-up of 187 days and average length of hospitalisation was 3.09 ± 0.61 days. Surgical duration was 128.18± 30.74 minutes. We experienced only 1 case of intraoperative low flow fistula with no further complications. None of the cases required any post- or intraoperative blood transfusion. The visualisation and high resolution of the operative field provided a very detailed view of all anatomical structures and pathologies allowing an improvement in safety and efficacy of the surgical procedure. The operative time was similar to the standard 2D HD and 3D procedures and the physical strain was also comparable to others in terms of ergonomics and weight. © Copyright by Società Italiana di Otorinolaringologia

  12. Volumetric image interpretation in radiology: scroll behavior and cognitive processes.

    Science.gov (United States)

    den Boer, Larissa; van der Schaaf, Marieke F; Vincken, Koen L; Mol, Chris P; Stuijfzand, Bobby G; van der Gijp, Anouk

    2018-05-16

    The interpretation of medical images is a primary task for radiologists. Besides two-dimensional (2D) images, current imaging technologies allow for volumetric display of medical images. Whereas current radiology practice increasingly uses volumetric images, the majority of studies on medical image interpretation is conducted on 2D images. The current study aimed to gain deeper insight into the volumetric image interpretation process by examining this process in twenty radiology trainees who all completed four volumetric image cases. Two types of data were obtained concerning scroll behaviors and think-aloud data. Types of scroll behavior concerned oscillations, half runs, full runs, image manipulations, and interruptions. Think-aloud data were coded by a framework of knowledge and skills in radiology including three cognitive processes: perception, analysis, and synthesis. Relating scroll behavior to cognitive processes showed that oscillations and half runs coincided more often with analysis and synthesis than full runs, whereas full runs coincided more often with perception than oscillations and half runs. Interruptions were characterized by synthesis and image manipulations by perception. In addition, we investigated relations between cognitive processes and found an overall bottom-up way of reasoning with dynamic interactions between cognitive processes, especially between perception and analysis. In sum, our results highlight the dynamic interactions between these processes and the grounding of cognitive processes in scroll behavior. It suggests, that the types of scroll behavior are relevant to describe how radiologists interact with and manipulate volumetric images.

  13. Processing Visual Images

    International Nuclear Information System (INIS)

    Litke, Alan

    2006-01-01

    The back of the eye is lined by an extraordinary biological pixel detector, the retina. This neural network is able to extract vital information about the external visual world, and transmit this information in a timely manner to the brain. In this talk, Professor Litke will describe a system that has been implemented to study how the retina processes and encodes dynamic visual images. Based on techniques and expertise acquired in the development of silicon microstrip detectors for high energy physics experiments, this system can simultaneously record the extracellular electrical activity of hundreds of retinal output neurons. After presenting first results obtained with this system, Professor Litke will describe additional applications of this incredible technology.

  14. Endoscopic therapy of neoplasia related to Barrett's esophagus and endoscopic palliation of esophageal cancer.

    Science.gov (United States)

    Vignesh, Shivakumar; Hoffe, Sarah E; Meredith, Kenneth L; Shridhar, Ravi; Almhanna, Khaldoun; Gupta, Akshay K

    2013-04-01

    Barrett's esophagus (BE) is the most important identifiable risk factor for the progression to esophageal adenocarcinoma. This article reviews the current endoscopic therapies for BE with high-grade dysplasia and intramucosal cancer and briefly discusses the endoscopic palliation of advanced esophageal cancer. The diagnosis of low-grade or high-grade dysplasia (HGD) is based on several cytologic criteria that suggest neoplastic transformation of the columnar epithelium. HGD and carcinoma in situ are regarded as equivalent. The presence of dysplasia, particularly HGD, is also a risk factor for synchronous and metachronous adenocarcinoma. Dysplasia is a marker of adenocarcinoma and also has been shown to be the preinvasive lesion. Esophagectomy has been the conventional treatment for T1 esophageal cancer and, although debated, is an appropriate option in some patients with HGD due to the presence of occult cancer in over one-third of patients. Endoscopic ablative modalities (eg, photodynamic therapy and cryoablation) and endoscopic resection techniques (eg, endoscopic mucosal resection) have demonstrated promising results. The significant morbidity and mortality of esophagectomy makes endoscopic treatment an attractive potential option.

  15. Optical characterization and polarization calibration for rigid endoscopes

    Science.gov (United States)

    Garcia, Missael; Gruev, Viktor

    2017-02-01

    Polarization measurements give orthogonal information to spectral images making them a great tool in the characterization of environmental parameters in nature. Thus, polarization imagery has proven to be remarkably useful in a vast range of biomedical applications. One such application is the early diagnosis of flat cancerous lesions in murine colorectal tumor models, where polarization data complements NIR fluorescence analysis. Advances in nanotechnology have led to compact and precise bio-inspired imaging sensors capable of accurately co-registering multidimensional spectral and polarization information. As more applications emerge for these imagers, the optics used in these instruments get very complex and can potentially compromise the original polarization state of the incident light. Here we present a complete optical and polarization characterization of three rigid endoscopes of size 1.9mm x 10cm (Karl Storz, Germany), 5mm x 30cm, and 10mm x 33cm (Olympus, Germany), used in colonoscopy for the prevention of colitis-associated cancer. Characterization results show that the telescope optics act as retarders and effectively depolarize the linear component. These incorrect readings can cause false-positives or false-negatives leading to an improper diagnosis. In this paper, we offer a polarization calibration scheme for these endoscopes based on Mueller calculus. By modeling the optical properties from training data as real-valued Mueller matrices, we are able to successfully reconstruct the initial polarization state acquired by the imaging system.

  16. Endoscope-Assisted Transoral Fixation of Mandibular Condyle Fractures: Submandibular Versus Transoral Endoscopic Approach.

    Science.gov (United States)

    Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo

    2016-07-01

    In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.

  17. Endoscopic Endonasal Versus Microscopic Transsphenoidal Surgery for Recurrent and/or Residual Pituitary Adenomas.

    Science.gov (United States)

    Esquenazi, Yoshua; Essayed, Walid I; Singh, Harminder; Mauer, Elizabeth; Ahmed, Mudassir; Christos, Paul J; Schwartz, Theodore H

    2017-05-01

    Surgery for recurrent/residual pituitary adenomas is increasingly being performed through endoscopic surgery. Whether this new technology has altered the indications and outcomes of surgery is unknown. We conducted a systematic review and meta-analysis of published studies to compare the indications and outcomes between microscopic and endoscopic approaches. A PubMed search was conducted (1985-2015) to identify surgical series of endoscopic endonasal and microscopic transsphenoidal resection of residual or recurrent pituitary adenomas. Data were extracted regarding tumor characteristics, surgical treatment, extent of resection, endocrine remission, visual outcome, and complications. Twenty-one studies met inclusion criteria. A total of 292 patients were in the endoscopic group, and 648 patients were in the microscopic group. Endoscopic cases were more likely nonfunctional (P < 0.001) macroadenomas (P < 0.001) with higher rates of cavernous sinus invasion (P = 0.012). The pooled rate of gross total tumor resection was 53.5% for the endoscopic group and 46.6% for the microscopic group. Endocrine remission was achieved in 53.0% and 46.7% of patients, and visual improvement occurred in 73.2% and 49.6% for the endoscopic and microscopic groups. Cerebrospinal fluid leak and pituitary insufficiency were higher in the endoscopic group. This meta-analysis indicates that the use of the endoscope to reoperate on residual or recurrent adenomas has only led to modest increases in resection rates. However, larger more complex cases are being tackled, so direct comparisons are misleading. The most dramatic change has been in visual improvement along with modest increases in risk. Reoperation for recurrent or residual adenomas is a safe and effective treatment option. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Miniature, minimally invasive, tunable endoscope for investigation of the middle ear.

    Science.gov (United States)

    Pawlowski, Michal E; Shrestha, Sebina; Park, Jesung; Applegate, Brian E; Oghalai, John S; Tkaczyk, Tomasz S

    2015-06-01

    We demonstrate a miniature, tunable, minimally invasive endoscope for diagnosis of the auditory system. The probe is designed to sharply image anatomical details of the middle ear without the need for physically adjusting the position of the distal end of the endoscope. This is achieved through the addition of an electrowetted, tunable, electronically-controlled lens to the optical train. Morphological imaging is enabled by scanning light emanating from an optical coherence tomography system. System performance was demonstrated by imaging part of the ossicular chain and wall of the middle ear cavity of a normal mouse. During the experiment, we electronically moved the plane of best focus from the incudo-stapedial joint to the stapedial artery. Repositioning the object plane allowed us to image anatomical details of the middle ear beyond the depth of field of a static optical system. We also demonstrated for the first time to our best knowledge, that an optical system with an electrowetted, tunable lens may be successfully employed to measure sound-induced vibrations within the auditory system by measuring the vibratory amplitude of the tympanic membrane in a normal mouse in response to pure tone stimuli.

  19. Prediction of Helicobacter pylori status by conventional endoscopy, narrow-band imaging magnifying endoscopy in stomach after endoscopic resection of gastric cancer.

    Science.gov (United States)

    Yagi, Kazuyoshi; Saka, Akiko; Nozawa, Yujiro; Nakamura, Atsuo

    2014-04-01

    To reduce the incidence of metachronous gastric carcinoma after endoscopic resection of early gastric cancer, Helicobacter pylori eradication therapy has been endorsed. It is not unusual for such patients to be H. pylori negative after eradication or for other reasons. If it were possible to predict H. pylori status using endoscopy alone, it would be very useful in clinical practice. To clarify the accuracy of endoscopic judgment of H. pylori status, we evaluated it in the stomach after endoscopic submucosal dissection (ESD) of gastric cancer. Fifty-six patients treated by ESD were enrolled. The diagnostic criteria for H. pylori status by conventional endoscopy and narrow-band imaging (NBI)-magnifying endoscopy were decided, and H. pylori status was judged by two endoscopists. Based on the H. pylori stool antigen test as a diagnostic gold standard, conventional endoscopy and NBI-magnifying endoscopy were compared for their sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Interobserver agreement was assessed in terms of κ value. Interobserver agreement was moderate (0.56) for conventional endoscopy and substantial (0.77) for NBI-magnifying endoscopy. The sensitivity, specificity, PPV, and NPV were 0.79, 0.52, 0.70, and 0.63 for conventional endoscopy and 0.91, 0.83, 0.88, and 0.86 for NBI-magnifying endoscopy, respectively. Prediction of H. pylori status using NBI-magnifying endoscopy is practical, and interobserver agreement is substantial. © 2013 John Wiley & Sons Ltd.

  20. Development and evaluation of a light-emitting diode endoscopic light source

    Science.gov (United States)

    Clancy, Neil T.; Li, Rui; Rogers, Kevin; Driscoll, Paul; Excel, Peter; Yandle, Ron; Hanna, George; Copner, Nigel; Elson, Daniel S.

    2012-03-01

    Light-emitting diode (LED) based endoscopic illumination devices have been shown to have several benefits over arclamp systems. LEDs are energy-efficient, small, durable, and inexpensive, however their use in endoscopy has been limited by the difficulty in efficiently coupling enough light into the endoscopic light cable. We have demonstrated a highly homogenised lightpipe LED light source that combines the light from four Luminus LEDs emitting in the red, green, blue and violet using innovative dichroics that maximise light throughput. The light source spectrally combines light from highly divergent incoherent sources that have a Lambertian intensity profile to provide illumination matched to the acceptance numerical aperture of a liquid light guide or fibre bundle. The LED light source was coupled to a standard laparoscope and performance parameters (power, luminance, colour temperature) compared to a xenon lamp. Although the total illuminance from the endoscope was lower, adjustment of the LEDs' relative intensities enabled contrast enhancement in biological tissue imaging. The LED light engine was also evaluated in a minimally invasive surgery (MIS) box trainer and in vivo during a porcine MIS procedure where it was used to generate 'narrowband' images. Future work using the violet LED could enable photodynamic diagnosis of bladder cancer.

  1. A Primer on Endoscopic Electronic Medical Records

    OpenAIRE

    Atreja, Ashish; Rizk, Maged; Gurland, Brooke

    2010-01-01

    Endoscopic electronic medical record systems (EEMRs) are now increasingly utilized in many endoscopy centers. Modern EEMRs not only support endoscopy report generation, but often include features such as practice management tools, image and video clip management, inventory management, e-faxes to referring physicians, and database support to measure quality and patient outcomes. There are many existing software vendors offering EEMRs, and choosing a software vendor can be time consuming and co...

  2. Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology

    International Nuclear Information System (INIS)

    Doi, Kunio

    2006-01-01

    Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image transmission, most of which are included in a picture archiving and communication system (PACS). The content of this paper includes a short review of research and development in medical imaging science and technology, which covers (a) diagnostic imaging in the 1950s, (b) the importance of image quality and diagnostic performance, (c) MTF, Wiener spectrum, NEQ and DQE, (d) ROC analysis, (e) analogue imaging systems, (f) digital imaging systems, (g) image processing, (h) computer-aided diagnosis, (i) PACS, (j) 3D imaging and (k) future directions. Although some of the modalities are already very sophisticated, further improvements will be made in image quality for MRI, ultrasound and molecular imaging. The infrastructure of PACS is likely to be improved further in terms of its reliability, speed and capacity. However, CAD is currently still in its infancy, and is likely to be a subject of research for a long time. (review)

  3. The role of surgeons in identifying emerging technologies for health technology assessment.

    Science.gov (United States)

    Stafinski, Tania; Topfer, Leigh-Ann; Zakariasen, Ken; Menon, Devidas

    2010-04-01

    Health technology assessment (HTA) is a tool intended to help policy-makers decide which technologies to fund. However, given the proliferation of new technologies, it is not possible to undertake an HTA of each one before it becomes funded. Consequently, "horizon-scanning" processes have been developed to identify emerging technologies that are likely to have a substantial impact on clinical practice. Although the importance of physicians in the adoption of new technologies is well recognized, their role in horizon scanning in Canada has been limited. The purpose of this project was to pilot an approach to engage physicians, specifically surgeons, in provincial horizon-scanning activities. We invited 18 surgeons from Alberta's 2 medical schools to a horizon-scanning workshop to solicit their views on emerging technologies expected to impact surgical practice within the next 5 years and/or the importance of different attributes or characteristics of new technologies. Surgeons, regardless of specialty, identified developments designed to enhance existing minimally invasive surgical techniques, such as endoscopic, robotic and image-guided surgery. Several nonsurgical areas, including molecular genetics and nano technology, were also identified. Of the 13 technology attributes discussed, safety or risk, effectiveness and feasibility were rated as most important. Lastly, participating surgeons expressed an interest in becoming further involved in local HTA initiatives. Surgeons, as adopters and users of health technologies, represent an important and accessible information source for identifying emerging technologies for HTA. A more formal, ongoing relationship between the government, HTA and surgeons may help to optimize the use of HTA resources.

  4. Image Sharing Technologies and Reduction of Imaging Utilization: A Systematic Review and Meta-analysis

    Science.gov (United States)

    Vest, Joshua R.; Jung, Hye-Young; Ostrovsky, Aaron; Das, Lala Tanmoy; McGinty, Geraldine B.

    2016-01-01

    Introduction Image sharing technologies may reduce unneeded imaging by improving provider access to imaging information. A systematic review and meta-analysis were conducted to summarize the impact of image sharing technologies on patient imaging utilization. Methods Quantitative evaluations of the effects of PACS, regional image exchange networks, interoperable electronic heath records, tools for importing physical media, and health information exchange systems on utilization were identified through a systematic review of the published and gray English-language literature (2004–2014). Outcomes, standard effect sizes (ESs), settings, technology, populations, and risk of bias were abstracted from each study. The impact of image sharing technologies was summarized with random-effects meta-analysis and meta-regression models. Results A total of 17 articles were included in the review, with a total of 42 different studies. Image sharing technology was associated with a significant decrease in repeat imaging (pooled effect size [ES] = −0.17; 95% confidence interval [CI] = [−0.25, −0.09]; P utilization (pooled ES = 0.20; 95% CI = [0.07, 0.32]; P = .002). For all outcomes combined, image sharing technology was not associated with utilization. Most studies were at risk for bias. Conclusions Image sharing technology was associated with reductions in repeat and unnecessary imaging, in both the overall literature and the most-rigorous studies. Stronger evidence is needed to further explore the role of specific technologies and their potential impact on various modalities, patient populations, and settings. PMID:26614882

  5. Reliability in endoscopic diagnosis of portal hypertensive gastropathy

    Science.gov (United States)

    de Macedo, George Fred Soares; Ferreira, Fabio Gonçalves; Ribeiro, Maurício Alves; Szutan, Luiz Arnaldo; Assef, Mauricio Saab; Rossini, Lucio Giovanni Battista

    2013-01-01

    AIM: To analyze reliability among endoscopists in diagnosing portal hypertensive gastropathy (PHG) and to determine which criteria from the most utilized classifications are the most suitable. METHODS: From January to July 2009, in an academic quaternary referral center at Santa Casa of São Paulo Endoscopy Service, Brazil, we performed this single-center prospective study. In this period, we included 100 patients, including 50 sequential patients who had portal hypertension of various etiologies; who were previously diagnosed based on clinical, laboratory and imaging exams; and who presented with esophageal varices. In addition, our study included 50 sequential patients who had dyspeptic symptoms and were referred for upper digestive endoscopy without portal hypertension. All subjects underwent upper digestive endoscopy, and the images of the exam were digitally recorded. Five endoscopists with more than 15 years of experience answered an electronic questionnaire, which included endoscopic criteria from the 3 most commonly used Portal Hypertensive Gastropathy classifications (McCormack, NIEC and Baveno) and the presence of elevated or flat antral erosive gastritis. All five endoscopists were blinded to the patients’ clinical information, and all images of varices were deliberately excluded for the analysis. RESULTS: The three most common etiologies of portal hypertension were schistosomiasis (36%), alcoholic cirrhosis (20%) and viral cirrhosis (14%). Of the 50 patients with portal hypertension, 84% were Child A, 12% were Child B, 4% were Child C, 64% exhibited previous variceal bleeding and 66% were previously endoscopic treated. The endoscopic parameters, presence or absence of mosaic-like pattern, red point lesions and cherry-red spots were associated with high inter-observer reliability and high specificity for diagnosing Portal Hypertensive Gastropathy. Sensitivity, specificity and reliability for the diagnosis of PHG (%) were as follows: mosaic-like pattern

  6. The development of machine technology processing for earth resource survey

    Science.gov (United States)

    Landgrebe, D. A.

    1970-01-01

    The following technologies are considered for automatic processing of earth resources data: (1) registration of multispectral and multitemporal images, (2) digital image display systems, (3) data system parameter effects on satellite remote sensing systems, and (4) data compression techniques based on spectral redundancy. The importance of proper spectral band and compression algorithm selections is pointed out.

  7. The experience of totally endoscopic coronary bypass grafting with the robotic system «Da Vinci» in Russia

    Science.gov (United States)

    Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.

    2015-11-01

    A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.

  8. Image processing and recognition for biological images.

    Science.gov (United States)

    Uchida, Seiichi

    2013-05-01

    This paper reviews image processing and pattern recognition techniques, which will be useful to analyze bioimages. Although this paper does not provide their technical details, it will be possible to grasp their main tasks and typical tools to handle the tasks. Image processing is a large research area to improve the visibility of an input image and acquire some valuable information from it. As the main tasks of image processing, this paper introduces gray-level transformation, binarization, image filtering, image segmentation, visual object tracking, optical flow and image registration. Image pattern recognition is the technique to classify an input image into one of the predefined classes and also has a large research area. This paper overviews its two main modules, that is, feature extraction module and classification module. Throughout the paper, it will be emphasized that bioimage is a very difficult target for even state-of-the-art image processing and pattern recognition techniques due to noises, deformations, etc. This paper is expected to be one tutorial guide to bridge biology and image processing researchers for their further collaboration to tackle such a difficult target. © 2013 The Author Development, Growth & Differentiation © 2013 Japanese Society of Developmental Biologists.

  9. Endoscopic ultrasound features of chronic pancreatitis

    DEFF Research Database (Denmark)

    Rana, Surinder Singh; Vilmann, Peter

    2015-01-01

    As endoscopic ultrasound (EUS) is the most sensitive imaging modality for diagnosing pancreatic disorders, it can demonstrate subtle alterations in the pancreatic parenchymal and ductal structure even before traditional imaging and functional testing demonstrate any abnormality. In spite...... of this fact and abundant literature, the exact role of EUS in the diagnosis of chronic pancreatitis (CP) is still not established. The EUS features to diagnose CP have evolved over a period from a pure qualitative approach to more advanced and complicated scoring systems incorporating multiple parenchymal...... to define the exact role of these criteria. The measurement of strain ratio using quantitative EUS elastography and thus allowing quantification of pancreatic fibrosis seems to be a promising new technique....

  10. Diagnosis of Acute Appendicitis by Endoscopic Retrograde Appendicitis Therapy (ERAT): Combination of Colonoscopy and Endoscopic Retrograde Appendicography.

    Science.gov (United States)

    Li, Yingchao; Mi, Chen; Li, Weizhi; She, Junjun

    2016-11-01

    Acute appendicitis is the most common abdominal emergency, but the diagnosis of appendicitis remains a challenge. Endoscopic retrograde appendicitis therapy (ERAT) is a new and minimally invasive procedure for the diagnosis and treatment of acute appendicitis. To investigate the diagnostic value of ERAT for acute appendicitis by the combination of colonoscopy and endoscopic retrograde appendicography (ERA). Twenty-one patients with the diagnosis of suspected uncomplicated acute appendicitis who underwent ERAT between November 2014 and January 2015 were included in this study. The main outcomes, imaging findings of acute appendicitis including colonoscopic direct-vision imaging and fluoroscopic ERA imaging, were retrospectively reviewed. Secondary outcomes included mean operative time, mean hospital stay, rate of complication, rate of appendectomy during follow-up period, and other clinical data. The diagnosis of acute appendicitis was established in 20 patients by positive ERA (5 patients) or colonoscopy (1 patient) alone or both (14 patients). The main colonoscopic imaging findings included mucosal inflammation (15/20, 75 %), appendicoliths (14/20, 70 %), and maturation (5/20, 25 %). The key points of ERA for diagnosing acute appendicitis included radiographic changes of appendix (17/20, 85 %), intraluminal appendicoliths (14/20, 70 %), and perforation (1/20, 5 %). Mean operative time of ERAT was 49.7 min, and mean hospital stay was 3.3 days. No patient converted to emergency appendectomy. Perforation occurred in one patient after appendicoliths removal was not severe and did not require invasive procedures. During at least 1-year follow-up period, only one patient underwent laparoscopic appendectomy. ERAT is a valuable procedure of choice providing a precise yield of diagnostic information for patients with suspected acute appendicitis by combination of colonoscopy and ERA.

  11. An integrated approach to endoscopic instrument tracking for augmented reality applications in surgical simulation training.

    Science.gov (United States)

    Loukas, Constantinos; Lahanas, Vasileios; Georgiou, Evangelos

    2013-12-01

    Despite the popular use of virtual and physical reality simulators in laparoscopic training, the educational potential of augmented reality (AR) has not received much attention. A major challenge is the robust tracking and three-dimensional (3D) pose estimation of the endoscopic instrument, which are essential for achieving interaction with the virtual world and for realistic rendering when the virtual scene is occluded by the instrument. In this paper we propose a method that addresses these issues, based solely on visual information obtained from the endoscopic camera. Two different tracking algorithms are combined for estimating the 3D pose of the surgical instrument with respect to the camera. The first tracker creates an adaptive model of a colour strip attached to the distal part of the tool (close to the tip). The second algorithm tracks the endoscopic shaft, using a combined Hough-Kalman approach. The 3D pose is estimated with perspective geometry, using appropriate measurements extracted by the two trackers. The method has been validated on several complex image sequences for its tracking efficiency, pose estimation accuracy and applicability in AR-based training. Using a standard endoscopic camera, the absolute average error of the tip position was 2.5 mm for working distances commonly found in laparoscopic training. The average error of the instrument's angle with respect to the camera plane was approximately 2°. The results are also supplemented by video segments of laparoscopic training tasks performed in a physical and an AR environment. The experiments yielded promising results regarding the potential of applying AR technologies for laparoscopic skills training, based on a computer vision framework. The issue of occlusion handling was adequately addressed. The estimated trajectory of the instruments may also be used for surgical gesture interpretation and assessment. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Endoscopic resection of subepithelial tumors.

    Science.gov (United States)

    Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel

    2014-12-16

    Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods.

  13. Industrial application of thermal image processing and thermal control

    Science.gov (United States)

    Kong, Lingxue

    2001-09-01

    Industrial application of infrared thermography is virtually boundless as it can be used in any situations where there are temperature differences. This technology has particularly been widely used in automotive industry for process evaluation and system design. In this work, thermal image processing technique will be introduced to quantitatively calculate the heat stored in a warm/hot object and consequently, a thermal control system will be proposed to accurately and actively manage the thermal distribution within the object in accordance with the heat calculated from the thermal images.

  14. The appearance of the pre-Achilles fat pad after endoscopic calcaneoplasty

    NARCIS (Netherlands)

    Wiegerinck, Johannes I.; Zwiers, Ruben; van Sterkenburg, Maayke N.; Maas, Mario M.; van Dijk, C. Niek

    2015-01-01

    To evaluate whether the imaging features of the retrocalcaneal recess normalize on a conventional radiograph after surgery for retrocalcaneal bursitis and evaluate whether it can be reused if complaints reoccur. Patients who underwent an endoscopic calcaneoplasty at least 2 years before were

  15. An Automated, Image Processing System for Concrete Evaluation

    International Nuclear Information System (INIS)

    Baumgart, C.W.; Cave, S.P.; Linder, K.E.

    1998-01-01

    Allied Signal Federal Manufacturing ampersand Technologies (FM ampersand T) was asked to perform a proof-of-concept study for the Missouri Highway and Transportation Department (MHTD), Research Division, in June 1997. The goal of this proof-of-concept study was to ascertain if automated scanning and imaging techniques might be applied effectively to the problem of concrete evaluation. In the current evaluation process, a concrete sample core is manually scanned under a microscope. Voids (or air spaces) within the concrete are then detected visually by a human operator by incrementing the sample under the cross-hairs of a microscope and by counting the number of ''pixels'' which fall within a void. Automation of the scanning and image analysis processes is desired to improve the speed of the scanning process, to improve evaluation consistency, and to reduce operator fatigue. An initial, proof-of-concept image analysis approach was successfully developed and demonstrated using acquired black and white imagery of concrete samples. In this paper, the automated scanning and image capture system currently under development will be described and the image processing approach developed for the proof-of-concept study will be demonstrated. A development update and plans for future enhancements are also presented

  16. Image Post-Processing and Analysis. Chapter 17

    Energy Technology Data Exchange (ETDEWEB)

    Yushkevich, P. A. [University of Pennsylvania, Philadelphia (United States)

    2014-09-15

    For decades, scientists have used computers to enhance and analyse medical images. At first, they developed simple computer algorithms to enhance the appearance of interesting features in images, helping humans read and interpret them better. Later, they created more advanced algorithms, where the computer would not only enhance images but also participate in facilitating understanding of their content. Segmentation algorithms were developed to detect and extract specific anatomical objects in images, such as malignant lesions in mammograms. Registration algorithms were developed to align images of different modalities and to find corresponding anatomical locations in images from different subjects. These algorithms have made computer aided detection and diagnosis, computer guided surgery and other highly complex medical technologies possible. Nowadays, the field of image processing and analysis is a complex branch of science that lies at the intersection of applied mathematics, computer science, physics, statistics and biomedical sciences. This chapter will give a general overview of the most common problems in this field and the algorithms that address them.

  17. Endoscopic Ultrasound in Endocrinology: Imaging of the Adrenals and the Endocrine Pancreas.

    Science.gov (United States)

    Kann, Peter Herbert

    2016-01-01

    Endoscopic ultrasound (EUS) imaging of adrenal glands and its application to diagnostic procedures of adrenal diseases has been reported since 1998. It can be considered a relevant advantage in the field of adrenal diseases. Indeed, EUS allows the detection of adrenal lesions (even very small ones) and their characterization, the assessment of malignancy criteria, the early detection of neoplastic recurrences, the preoperative identification of morphologically healthy parts of the glands, the differentiation of extra-adrenal from adrenal tumors, and of the pathological entities associated with adrenal insufficiency, and the fine-needle aspiration biopsy (EUS-FNA) of suspicious lesions. At the same time, its clinical relevance depends on the experience of the endosonographer. Moreover, EUS is also by far the best and most sensitive imaging technique to detect and assess the follow-up of pancreatic manifestation of MEN1 disease. It furthermore enables the preoperatively localization of insulinomas and critical structures in their neighborhood, and may be relevant in planning surgical strategy. A positive EUS in a case of insulinoma furthermore confirms the endocrine diagnosis, especially considering the differential diagnosis of hypoglycemia factitia by oral antidiabetics. It can be supplemented by EUS-FNA. Again, it has to be considered that EUS may reveal false positive and false negative results, and the quality of the findings largely depends on the endosonographer's skills and experience. The most important technical details together with the advantages and limitations of EUS, and the pathognomonic characteristic of benign and malignant disorders of the adrenals and pancreas are presented here. © 2016 S. Karger AG, Basel.

  18. A new robotic-assisted flexible endoscope with single-hand control: endoscopic submucosal dissection in the ex vivo porcine stomach.

    Science.gov (United States)

    Iwasa, Tsutomu; Nakadate, Ryu; Onogi, Shinya; Okamoto, Yasuharu; Arata, Jumpei; Oguri, Susumu; Ogino, Haruei; Ihara, Eikichi; Ohuchida, Kenoki; Akahoshi, Tomohiko; Ikeda, Tetsuo; Ogawa, Yoshihiro; Hashizume, Makoto

    2018-04-17

    Difficulties in endoscopic operations and therapeutic procedures seem to occur due to the complexity of operating the endoscope dial as well as difficulty in performing synchronized movements with both hands. We developed a prototype robotic-assisted flexible endoscope that can be controlled with a single hand in order to simplify the operation of the endoscope. The aim of this study was to confirm the operability of the robotic-assisted flexible endoscope (RAFE) by performing endoscopic submucosal dissection (ESD). Study 1: ESD was performed manually or with RAFE by an expert endoscopist in ex vivo porcine stomachs; six operations manually and six were performed with RAFE. The procedure time per unit circumferential length/area was calculated, and the results were statistically analyzed. Study 2: We evaluated how smoothly a non-endoscopist can move a RAFE compared to a manual endoscope by assessing the designated movement of the endoscope. Study 1: En bloc resection was achieved by ESD using the RAFE. The procedure time was gradually shortened with increasing experience, and the procedure time of ESD performed with the RAFE was not significantly different from that of ESD performed with a manual endoscope. Study 2: The time for the designated movement of the endoscope was significantly shorter with a RAFE than that with a manual endoscope as for a non-endoscopist. The RAFE that we developed enabled an expert endoscopist to perform the ESD procedure without any problems and allowed a non-endoscopist to control the endoscope more easily and quickly than a manual endoscope. The RAFE is expected to undergo further development.

  19. Research on Remote Sensing Image Template Processing Based on Global Subdivision Theory

    OpenAIRE

    Xiong Delan; Du Genyuan

    2013-01-01

    Aiming at the questions of vast data, complex operation, and time consuming processing for remote sensing image, subdivision template was proposed based on global subdivision theory, which can set up high level of abstraction and generalization for remote sensing image. The paper emphatically discussed the model and structure of subdivision template, and put forward some new ideas for remote sensing image template processing, key technology and quickly applied demonstration. The research has ...

  20. Design and fabrication process of silicon micro-calorimeters on simple SOI technology for X-ray spectral imaging

    International Nuclear Information System (INIS)

    Aliane, A.; Agnese, P.; Pigot, C.; Sauvageot, J.-L.; Moro, F. de; Ribot, H.; Gasse, A.; Szeflinski, V.; Gobil, Y.

    2008-01-01

    Several successful development programs have been conducted on infra-red bolometer arrays at the 'Commissariat a l'Energie Atomique' (CEA-LETI Grenoble) in collaboration with the CEA-SAp (Saclay); taking advantage of this background, we are now developing an X-ray spectro-imaging camera for next generation space astronomy missions, using silicon only technology. We have developed monolithic silicon micro-calorimeters based on implanted thermistors in an improved array that could be used for future space missions. The 8x8 array consists of a grid of 64 suspended pixels fabricated on a silicon on insulator (SOI) wafer. Each pixel of this detector array is made of a tantalum (Ta) absorber, which is bound by means of indium bump hybridization, to a silicon thermistor. The absorber array is bound to the thermistor array in a collective process. The fabrication process of our detector involves a combination of standard technologies and silicon bulk micro-machining techniques, based on deposition, photolithography and plasma etching steps. Finally, we present the results of measurements performed on these four primary building blocks that are required to create a detector array up to 32x32 pixels in size

  1. Accuracy of endoscopic ultrasonography for diagnosing ulcerative early gastric cancers

    Science.gov (United States)

    Park, Jin-Seok; Kim, Hyungkil; Bang, Byongwook; Kwon, Kyesook; Shin, Youngwoon

    2016-01-01

    Abstract Although endoscopic ultrasonography (EUS) is the first-choice imaging modality for predicting the invasion depth of early gastric cancer (EGC), the prediction accuracy of EUS is significantly decreased when EGC is combined with ulceration. The aim of present study was to compare the accuracy of EUS and conventional endoscopy (CE) for determining the depth of EGC. In addition, the various clinic-pathologic factors affecting the diagnostic accuracy of EUS, with a particular focus on endoscopic ulcer shapes, were evaluated. We retrospectively reviewed data from 236 consecutive patients with ulcerative EGC. All patients underwent EUS for estimating tumor invasion depth, followed by either curative surgery or endoscopic treatment. The diagnostic accuracy of EUS and CE was evaluated by comparing the final histologic result of resected specimen. The correlation between accuracy of EUS and characteristics of EGC (tumor size, histology, location in stomach, tumor invasion depth, and endoscopic ulcer shapes) was analyzed. Endoscopic ulcer shapes were classified into 3 groups: definite ulcer, superficial ulcer, and ill-defined ulcer. The overall accuracy of EUS and CE for predicting the invasion depth in ulcerative EGC was 68.6% and 55.5%, respectively. Of the 236 patients, 36 patients were classified as definite ulcers, 98 were superficial ulcers, and 102 were ill-defined ulcers, In univariate analysis, EUS accuracy was associated with invasion depth (P = 0.023), tumor size (P = 0.034), and endoscopic ulcer shapes (P = 0.001). In multivariate analysis, there is a significant association between superficial ulcer in CE and EUS accuracy (odds ratio: 2.977; 95% confidence interval: 1.255–7.064; P = 0.013). The accuracy of EUS for determining tumor invasion depth in ulcerative EGC was superior to that of CE. In addition, ulcer shape was an important factor that affected EUS accuracy. PMID:27472672

  2. Our Experience with 67 Cases of Percutaneous Transforaminal Endoscopic Lumbar Discectomy

    Directory of Open Access Journals (Sweden)

    Mehmat Ozer

    2016-07-01

    Full Text Available Aim: Minimally invasive interventions have become increasingly popular with the developments in technology and surgical tools. In this article, we present our experience with 67 cases of percutaneous transforaminal endoscopic lumbar discectomy. Material and Method: A total of 67 cases that underwent endoscopic surgery for foraminal and extraforaminal disc hernia between 2004 and 2010 were retrospectively examined. Results: The mean pre-operative VAS score was 8.13. The mean post-operative VAS score was 2.4 in the 1st month and 2.01 in the 12th month. Satisfaction according to MacNab criteria in the 12th month was excellent in 35 (52.2% patients, good in 18 (26.9% patients, fair in 11 (16.4% patients, and poor in 3 (4.5% patients. Microdiscectomy was required due to continuing symptoms in 3 patients (4.5%. Temporary dysesthesia was found in 3 patients. Discussion: Percutaneous endoscopic discectomy has become a good alternative to microsurgery for foraminal and extraforaminal disc herniations because of the developments in technology and surgical tools as well as the increased experience of surgeons. The technique is not limited to these localizations; it can also be used for free fragments within the channel, recurrent disc herniations, and narrow channels.

  3. Endoscopic Management of Early Adenocarcinoma and Squamous Cell Carcinoma of the Esophagus: Screening, Diagnosis, and Therapy.

    Science.gov (United States)

    di Pietro, Massimiliano; Canto, Marcia I; Fitzgerald, Rebecca C

    2018-01-01

    Because the esophagus is easily accessible with endoscopy, early diagnosis and curative treatment of esophageal cancer is possible. However, diagnosis is often delayed because symptoms are not specific during early stages of tumor development. The onset of dysphagia is associated with advanced disease, which has a survival at 5 years lower than 15%. Population screening by endoscopy is not cost-effective, but a number of alternative imaging and cell analysis technologies are under investigation. The ideal screening test should be inexpensive, well tolerated, and applicable to primary care. Over the past 10 years, significant progress has been made in endoscopic diagnosis and treatment of dysplasia (squamous and Barrett's), and early esophageal cancer using resection and ablation technologies supported by evidence from randomized controlled trials. We review the state-of-the-art technologies for early diagnosis and minimally invasive treatment, which together could reduce the burden of disease. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  4. Caught in the act: revealing the metastatic process by live imaging

    Directory of Open Access Journals (Sweden)

    Miriam R. Fein

    2013-05-01

    Full Text Available The prognosis of metastatic cancer in patients is poor. Interfering with metastatic spread is therefore important for achieving better survival from cancer. Metastatic disease is established through a series of steps, including breaching of the basement membrane, intravasation and survival in lymphatic or blood vessels, extravasation, and growth at distant sites. Yet, although we know the steps involved in metastasis, the cellular and molecular mechanisms of dissemination and colonization of distant organs are incompletely understood. Here, we review the important insights into the metastatic process that have been gained specifically through the use of imaging technologies in murine, chicken embryo and zebrafish model systems, including high-resolution two-photon microscopy and bioluminescence. We further discuss how imaging technologies are beginning to allow researchers to address the role of regional activation of specific molecular pathways in the metastatic process. These technologies are shedding light, literally, on almost every step of the metastatic process, particularly with regards to the dynamics and plasticity of the disseminating cancer cells and the active participation of the microenvironment in the processes.

  5. Problems forming innovative-technological image of russian regions

    Directory of Open Access Journals (Sweden)

    Irina Markovna Golova

    2012-06-01

    Full Text Available In this paper, actual problems of innovative-technological image as a key element of the mechanism of the healing sources of socioeconomic development of the Russian regionsare considered. The author gives an assessment of the level of differentiation of subjects of the Russian Federation on the potential for innovative development. Trends in spatial transformations of thescientific and technical and innovation capacities of the country are analyzedand reasons of low innovational activity of Russian enterprises are disclosed. Basic conditions for the success of actions to create an attractive image of innovative-technological territory are formulated. Special attention is paid to the position of regions as participants in the innovational processes, creating preconditions for creativity, harmonization of spatial priorities of innovation, technological and socio-economic development, support for the development of new high-tech industries, improvement of inter-budgetary relations. There are proved priority areas of state policy to reduce barriers to the realization of an innovative paradigm for development of Russian society and effective inclusion of local communities in the implementation of innovative changes.

  6. scikit-image: image processing in Python.

    Science.gov (United States)

    van der Walt, Stéfan; Schönberger, Johannes L; Nunez-Iglesias, Juan; Boulogne, François; Warner, Joshua D; Yager, Neil; Gouillart, Emmanuelle; Yu, Tony

    2014-01-01

    scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  7. scikit-image: image processing in Python

    Directory of Open Access Journals (Sweden)

    Stéfan van der Walt

    2014-06-01

    Full Text Available scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  8. EMITEL: E-Encyclopaedia and E-Dictionary of Medical Imaging Technologies

    International Nuclear Information System (INIS)

    Medvedec, M.; Kovacevic, N.; Magjarevic, R.

    2011-01-01

    EMITEL (European Medical Imaging Technology e-Encyclopaedia for Lifelong Learning) is an electronic encyclopaedia and multilingual dictionary related to medical imaging technologies. It is a result of the multi-annual international project which involved more than 250 contributors from 35 countries, aiming to foster development of medical physics and biomedical/clinical engineering by a lifelong e-learning web tool for all interested individuals or groups. Currently, the encyclopaedia is equivalent to about 2100 hard copy pages and includes about 3300 terms with an explanatory article for each term. The dictionary provides bidirectional cross-translation of terms between any two among 28 languages from its current database. Dictionary entries are divided into seven groups: diagnostic radiology, nuclear medicine, radiotherapy, magnetic resonance imaging, ultrasound imaging, radiation protection and general terms. Croatian language was implemented in EMITEL dictionary in April 2010. There were 17 Croatian translators and reviewers from 8 institutions and 3 cities, ranging from medical physics experts to linguist. The basic terminological principles of translation were final intelligibility of terms, desirable Croatian origin and linguistic appropriateness. Croatian contribution in the actual phase of EMITEL project attempted to improve the quality and efficiency of the specific professional, scientific and teaching terminology. A sort of novel, consistent and verified pool of terms of emerging medical imaging technologies was built up, as a one small part of the process of developing information technologies and socio-cultural transition from the industrial society into the society of knowledge. (author)

  9. Brachial plexus endoscopic dissection and correlation with open dissection.

    Science.gov (United States)

    Lafosse, T; Masmejean, E; Bihel, T; Lafosse, L

    2015-12-01

    Shoulder endoscopy is evolving and becoming extra-articular. More and more procedures are taking place in the area of the brachial plexus (BP). We carried out an anatomical study to describe the endoscopic anatomy of the BP and the technique used to dissect and expose the BP endoscopically. Thirteen fresh cadavers were dissected. We first performed an endoscopic dissection of the BP, using classical extra-articular shoulder arthroscopy portals. Through each portal, we dissected as many structures as possible and identified them. We then did an open dissection to corroborate the endoscopic findings and to look for damage to the neighboring structures. In the supraclavicular area, we were able to expose the C5, C6 and C7 roots, and the superior and middle trunks in 11 of 13 specimens through two transtrapezial portals by following the suprascapular nerve. The entire infraclavicular portion of the BP (except the medial cord and its branches) was exposed in 11 of 13 specimens. The approach to the infraclavicular portion of the BP led directly to the lateral and posterior cords, but the axillary artery hid the medial cord. The musculocutaneous nerve was the first nerve encountered when dissecting medially from the anterior aspect of the coracoid process. The axillary nerve was the first nerve encountered when following the anterior border of the subscapularis medially from the posterior aspect of the coracoid process. Knowledge of the endoscopic anatomy of the BP is mandatory to expose and protect this structure while performing advanced arthroscopic shoulder procedures. Copyright © 2015 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  10. Endoscopic approaches to treatment of achalasia

    Science.gov (United States)

    Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.

    2013-01-01

    Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707

  11. Augmented environments for the targeting of hepatic lesions during image-guided robotic liver surgery.

    Science.gov (United States)

    Buchs, Nicolas C; Volonte, Francesco; Pugin, François; Toso, Christian; Fusaglia, Matteo; Gavaghan, Kate; Majno, Pietro E; Peterhans, Matthias; Weber, Stefan; Morel, Philippe

    2013-10-01

    Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study

    Science.gov (United States)

    Li, Liang; Yang, Jian; Chu, Yakui; Wu, Wenbo; Xue, Jin; Liang, Ping; Chen, Lei

    2016-01-01

    Objective To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery. Materials and Methods In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems. Results The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D) virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons. Conclusion The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon’s skills and knowledge, not as a substitute. PMID:26757365

  13. A Novel Augmented Reality Navigation System for Endoscopic Sinus and Skull Base Surgery: A Feasibility Study.

    Directory of Open Access Journals (Sweden)

    Liang Li

    Full Text Available To verify the reliability and clinical feasibility of a self-developed navigation system based on an augmented reality technique for endoscopic sinus and skull base surgery.In this study we performed a head phantom and cadaver experiment to determine the display effect and accuracy of our navigational system. We compared cadaver head-based simulated operations, the target registration error, operation time, and National Aeronautics and Space Administration Task Load Index scores of our navigation system to conventional navigation systems.The navigation system developed in this study has a novel display mode capable of fusing endoscopic images to three-dimensional (3-D virtual images. In the cadaver head experiment, the target registration error was 1.28 ± 0.45 mm, which met the accepted standards of a navigation system used for nasal endoscopic surgery. Compared with conventional navigation systems, the new system was more effective in terms of operation time and the mental workload of surgeons, which is especially important for less experienced surgeons.The self-developed augmented reality navigation system for endoscopic sinus and skull base surgery appears to have advantages that outweigh those of conventional navigation systems. We conclude that this navigational system will provide rhinologists with more intuitive and more detailed imaging information, thus reducing the judgment time and mental workload of surgeons when performing complex sinus and skull base surgeries. Ultimately, this new navigational system has potential to increase the quality of surgeries. In addition, the augmented reality navigational system could be of interest to junior doctors being trained in endoscopic techniques because it could speed up their learning. However, it should be noted that the navigation system serves as an adjunct to a surgeon's skills and knowledge, not as a substitute.

  14. Methods in Astronomical Image Processing

    Science.gov (United States)

    Jörsäter, S.

    A Brief Introductory Note History of Astronomical Imaging Astronomical Image Data Images in Various Formats Digitized Image Data Digital Image Data Philosophy of Astronomical Image Processing Properties of Digital Astronomical Images Human Image Processing Astronomical vs. Computer Science Image Processing Basic Tools of Astronomical Image Processing Display Applications Calibration of Intensity Scales Calibration of Length Scales Image Re-shaping Feature Enhancement Noise Suppression Noise and Error Analysis Image Processing Packages: Design of AIPS and MIDAS AIPS MIDAS Reduction of CCD Data Bias Subtraction Clipping Preflash Subtraction Dark Subtraction Flat Fielding Sky Subtraction Extinction Correction Deconvolution Methods Rebinning/Combining Summary and Prospects for the Future

  15. Relationships of virtual reality neuroendoscopic simulations to actual imaging.

    Science.gov (United States)

    Riegel, T; Alberti, O; Retsch, R; Shiratori, V; Hellwig, D; Bertalanffy, H

    2000-12-01

    Advances in computer technology have permitted virtual reality images of the ventricular system. To determine the relevance of these images we have compared virtual reality simulations of the ventricular system with endoscopic findings in three patients. The virtual fly-through can be simulated after definition of waypoints. Flight objects of interest can be viewed from all sides. Important drawbacks are that filigree structures may be missed and blood vessels cannot be distinguished clearly. However, virtual endoscopy can presently be used as a planning tool or for training and has future potential for neurosurgery.

  16. Digital image processing in neutron radiography

    International Nuclear Information System (INIS)

    Koerner, S.

    2000-11-01

    Neutron radiography is a method for the visualization of the macroscopic inner-structure and material distributions of various samples. The basic experimental arrangement consists of a neutron source, a collimator functioning as beam formatting assembly and of a plane position sensitive integrating detector. The object is placed between the collimator exit and the detector, which records a two dimensional image. This image contains information about the composition and structure of the sample-interior, as a result of the interaction of neutrons by penetrating matter. Due to rapid developments of detector and computer technology as well as deployments in the field of digital image processing, new technologies are nowadays available which have the potential to improve the performance of neutron radiographic investigations enormously. Therefore, the aim of this work was to develop a state-of-the art digital imaging device, suitable for the two neutron radiography stations located at the 250 kW TRIGA Mark II reactor at the Atominstitut der Oesterreichischen Universitaeten and furthermore, to identify and develop two and three dimensional digital image processing methods suitable for neutron radiographic and tomographic applications, and to implement and optimize them within data processing strategies. The first step was the development of a new imaging device fulfilling the requirements of a high reproducibility, easy handling, high spatial resolution, a large dynamic range, high efficiency and a good linearity. The detector output should be inherently digitized. The key components of the detector system selected on the basis of these requirements consist of a neutron sensitive scintillator screen, a CCD-camera and a mirror to reflect the light emitted by the scintillator to the CCD-camera. This detector design enables to place the camera out of the direct neutron beam. The whole assembly is placed in a light shielded aluminum box. The camera is controlled by a

  17. Digital image processing in neutron radiography

    International Nuclear Information System (INIS)

    Koerner, S.

    2000-11-01

    Neutron radiography is a method for the visualization of the macroscopic inner-structure and material distributions of various materials. The basic experimental arrangement consists of a neutron source, a collimator functioning as beam formatting assembly and of a plane position sensitive integrating detector. The object is placed between the collimator exit and the detector, which records a two dimensional image. This image contains information about the composition and structure of the sample-interior, as a result of the interaction of neutrons by penetrating matter. Due to rapid developments of detector and computer technology as well as deployments in the field of digital image processing, new technologies are nowadays available which have the potential to improve the performance of neutron radiographic investigations enormously. Therefore, the aim of this work was to develop a state-of-the art digital imaging device, suitable for the two neutron radiography stations located at the 250 kW TRIGA Mark II reactor at the Atominstitut der Oesterreichischen Universitaeten and furthermore, to identify and develop two and three dimensional digital image processing methods suitable for neutron radiographic and tomographic applications, and to implement and optimize them within data processing strategies. The first step was the development of a new imaging device fulfilling the requirements of a high reproducibility, easy handling, high spatial resolution, a large dynamic range, high efficiency and a good linearity. The detector output should be inherently digitized. The key components of the detector system selected on the basis of these requirements consist of a neutron sensitive scintillator screen, a CCD-camera and a mirror to reflect the light emitted by the scintillator to the CCD-camera. This detector design enables to place the camera out of the direct neutron beam. The whole assembly is placed in a light shielded aluminum box. The camera is controlled by a

  18. Multimedia Image Technology and Computer Aided Manufacturing Engineering Analysis

    Science.gov (United States)

    Nan, Song

    2018-03-01

    Since the reform and opening up, with the continuous development of science and technology in China, more and more advanced science and technology have emerged under the trend of diversification. Multimedia imaging technology, for example, has a significant and positive impact on computer aided manufacturing engineering in China. From the perspective of scientific and technological advancement and development, the multimedia image technology has a very positive influence on the application and development of computer-aided manufacturing engineering, whether in function or function play. Therefore, this paper mainly starts from the concept of multimedia image technology to analyze the application of multimedia image technology in computer aided manufacturing engineering.

  19. IDP++: signal and image processing algorithms in C++ version 4.1

    International Nuclear Information System (INIS)

    Lehman, S.K.

    1996-11-01

    IDP++ (Image and Data Processing in C++) is a collection of signal and image processing algorithms written in C++. It is a compiled signal processing environment which supports four data types of up to four dimensions. It is developed within Lawrence Livermore National Laboratory's Image and Data Processing group as a partial replacement for View. IDP ++ takes advantage of the latest, implemented and actually working, object-oriented compiler technology to provide 'information hiding.' Users need only know C, not C++. Signals are treated like any other variable with a defined set of operators and functions in an intuitive manner. IDP++ is designed for real-time environment where interpreted processing packages are less efficient. IDP++ exists for both SUNs and Silicon Graphics using their most current compilers

  20. Rethinking and Redesigning an Image Processing Course from a Problem-Based Learning Perspective

    DEFF Research Database (Denmark)

    Reng, Lars; Triantafyllou, Evangelia; Triantafyllidis, George

    2015-01-01

    of such concepts and being able to use them for solving real-world problems. The Problem-Based Learning (PBL) pedagogy is an approach, which favours learning by applying knowledge to solve such problems. However, formulating an appropriate project for image processing courses presents challenges on how......Our experience at the Media Technology department, Aalborg University Copenhangen has shown that learning core concepts and techniques in image processing is a challenge for undergraduate students. One possible cause for this is the gap between understanding the mathematical formalism...... to appropriately present relevant concepts and techniques to students. This article presents our redesign of an image processing course at the Media Technology department, which focused on relevant concept and technique presentation and design projects and employed a game engine (Unity) in order to present...

  1. [Endoscopic extraction of gallbladder calculi].

    Science.gov (United States)

    Kühner, W; Frimberger, E; Ottenjann, R

    1984-06-29

    Endoscopic extraction of gallbladder stones were performed, as far as we know for the first time, in three patients with combined choledochocystolithiasis. Following endoscopic papillotomy (EPT) and subsequent mechanical lithotripsy of multiple choledochal concrements measuring up to 3 cm the gallbladder stones were successfully extracted with a Dormia basket through the cystic duct. The patients have remained free of complications after the endoscopic intervention.

  2. Application of stereo-imaging technology to medical field.

    Science.gov (United States)

    Nam, Kyoung Won; Park, Jeongyun; Kim, In Young; Kim, Kwang Gi

    2012-09-01

    There has been continuous development in the area of stereoscopic medical imaging devices, and many stereoscopic imaging devices have been realized and applied in the medical field. In this article, we review past and current trends pertaining to the application stereo-imaging technologies in the medical field. We describe the basic principles of stereo vision and visual issues related to it, including visual discomfort, binocular disparities, vergence-accommodation mismatch, and visual fatigue. We also present a brief history of medical applications of stereo-imaging techniques, examples of recently developed stereoscopic medical devices, and patent application trends as they pertain to stereo-imaging medical devices. Three-dimensional (3D) stereo-imaging technology can provide more realistic depth perception to the viewer than conventional two-dimensional imaging technology. Therefore, it allows for a more accurate understanding and analysis of the morphology of an object. Based on these advantages, the significance of stereoscopic imaging in the medical field increases in accordance with the increase in the number of laparoscopic surgeries, and stereo-imaging technology plays a key role in the diagnoses of the detailed morphologies of small biological specimens. The application of 3D stereo-imaging technology to the medical field will help improve surgical accuracy, reduce operation times, and enhance patient safety. Therefore, it is important to develop more enhanced stereoscopic medical devices.

  3. Opportunities and applications of medical imaging and image processing techniques for nondestructive testing

    International Nuclear Information System (INIS)

    Song, Samuel Moon Ho; Cho, Jung Ho; Son, Sang Rock; Sung, Je Jonng; Ahn, Hyung Keun; Lee, Jeong Soon

    2002-01-01

    Nondestructive testing (NDT) of structures strives to extract all relevant data regarding the state of the structure without altering its form or properties. The success enjoyed by imaging and image processing technologies in the field of modem medicine forecasts similar success of image processing related techniques both in research and practice of NDT. In this paper, we focus on two particular instances of such applications: a modern vision technique for 3-D profile and shape measurement, and ultrasonic imaging with rendering for 3-D visualization. Ultrasonic imaging of 3-D structures for nondestructive evaluation purposes must provide readily recognizable 3-D images with enough details to clearly show various faults that may or may not be present. As a step towards Improving conspicuity and thus detection of faults, we propose a pulse-echo ultrasonic imaging technique to generate a 3-D image of the 3-D object under evaluation through strategic scanning and processing of the pulse-echo data. This three-dimensional processing and display improves conspicuity of faults and in addition, provides manipulation capabilities, such as pan and rotation of the 3-D structure. As a second application, we consider an image based three-dimensional shape determination system. The shape, and thus the three-dimensional coordinate information of the 3-D object, is determined solely from captured images of the 3-D object from a prescribed set of viewpoints. The approach is based on the shape from silhouette (SFS) technique and the efficacy of the SFS method is tested using a sample data set. This system may be used to visualize the 3-D object efficiently, or to quickly generate initial CAD data for reverse engineering purposes. The proposed system potentially may be used in three dimensional design applications such as 3-D animation and 3-D games.

  4. Endoscope-guided pneumatic dilation for treatment of esophageal achalasia

    Science.gov (United States)

    Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin

    2010-01-01

    Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764

  5. The development of application technology for image processing in nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Jong Min; Lee, Yong Bum; Kim, Woong Ki; Kim, Seung Ho; Kim, Chang Hoe; Kim, Byung Soo; Sohn, Surg Won; Hwang, Suk Yeoung

    1992-01-01

    In this study, first, the prototype of the radiation level monitoring system as well as the monitoring algorithms is developed. Secondly, the pattern recognition algorithms are developed for robot vision. As the results of the experiments, the radiation level distribution is surveyed through two dimensional data acquired by the prototype. Also, the number images and bolt images are accurately recognized by the pattern recognition algorithms. It is expected that not only radiation level monitoring system but the pattern recognition algorithms will be adopted to development of the nuclear intelligent robot in the process of being performed in this laboratory. (Author)

  6. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  7. New solutions and applications of 3D computer tomography image processing

    Science.gov (United States)

    Effenberger, Ira; Kroll, Julia; Verl, Alexander

    2008-02-01

    As nowadays the industry aims at fast and high quality product development and manufacturing processes a modern and efficient quality inspection is essential. Compared to conventional measurement technologies, industrial computer tomography (CT) is a non-destructive technology for 3D-image data acquisition which helps to overcome their disadvantages by offering the possibility to scan complex parts with all outer and inner geometric features. In this paper new and optimized methods for 3D image processing, including innovative ways of surface reconstruction and automatic geometric feature detection of complex components, are presented, especially our work of developing smart online data processing and data handling methods, with an integrated intelligent online mesh reduction. Hereby the processing of huge and high resolution data sets is guaranteed. Besides, new approaches for surface reconstruction and segmentation based on statistical methods are demonstrated. On the extracted 3D point cloud or surface triangulation automated and precise algorithms for geometric inspection are deployed. All algorithms are applied to different real data sets generated by computer tomography in order to demonstrate the capabilities of the new tools. Since CT is an emerging technology for non-destructive testing and inspection more and more industrial application fields will use and profit from this new technology.

  8. Endoscopic findings following retroperitoneal pancreas transplantation.

    Science.gov (United States)

    Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M

    2017-07-01

    An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. iMAGE cloud: medical image processing as a service for regional healthcare in a hybrid cloud environment.

    Science.gov (United States)

    Liu, Li; Chen, Weiping; Nie, Min; Zhang, Fengjuan; Wang, Yu; He, Ailing; Wang, Xiaonan; Yan, Gen

    2016-11-01

    To handle the emergence of the regional healthcare ecosystem, physicians and surgeons in various departments and healthcare institutions must process medical images securely, conveniently, and efficiently, and must integrate them with electronic medical records (EMRs). In this manuscript, we propose a software as a service (SaaS) cloud called the iMAGE cloud. A three-layer hybrid cloud was created to provide medical image processing services in the smart city of Wuxi, China, in April 2015. In the first step, medical images and EMR data were received and integrated via the hybrid regional healthcare network. Then, traditional and advanced image processing functions were proposed and computed in a unified manner in the high-performance cloud units. Finally, the image processing results were delivered to regional users using the virtual desktop infrastructure (VDI) technology. Security infrastructure was also taken into consideration. Integrated information query and many advanced medical image processing functions-such as coronary extraction, pulmonary reconstruction, vascular extraction, intelligent detection of pulmonary nodules, image fusion, and 3D printing-were available to local physicians and surgeons in various departments and healthcare institutions. Implementation results indicate that the iMAGE cloud can provide convenient, efficient, compatible, and secure medical image processing services in regional healthcare networks. The iMAGE cloud has been proven to be valuable in applications in the regional healthcare system, and it could have a promising future in the healthcare system worldwide.

  10. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    NARCIS (Netherlands)

    F.J.C. van den Broek (Frank); E.J.R. de Graaf (Eelco); M.G.W. Dijkgraaf (Marcel); J.B. Reitsma (Johannes); J. Haringsma (Jelle); R. Timmer (Robin); B.L. Weusten (Bas); M.F. Gerhards (Michael); E.C. Consten (Esther); M.P. Schwartz (Matthijs); M.J. Boom (Maarten); E.J. Derksen (Erik); A.B. Bijnen (Bart); P.H.P. Davids (Paul); C. Hoff (Christiaan); H.M. van Dullemen (Hendrik); G.D.N. Heine (Dimitri); K. van der Linde (Klaas); J.M. Jansen (Jeroen); R.C.H. Mallant-Hent (Rosalie); R. Breumelhof (Ronald); H. Geldof (Han); J.C. Hardwick (James); P. Doornebosch (Pascal); A.C.T.M. Depla (Annekatrien); M.F. Ernst (Miranda); I.P. van Munster (Ivo); I.H.J.T. de Hingh (Ignace); E.J. Schoon (Erik); W.A. Bemelman (Willem); P. Fockens (Paul); E. Dekker (Evelien)

    2009-01-01

    textabstractBackground: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does

  11. Extended Transsphenoidal Endoscopic Endonasal Surgery of Suprasellar Craniopharyngiomas.

    Science.gov (United States)

    Fomichev, Dmitry; Kalinin, Pavel; Kutin, Maxim; Sharipov, Oleg

    2016-10-01

    The endoscopic extended transsphenoidal approach for suprasellar craniopharyngiomas may be a really alternative to the transcranial approach in many cases. The authors present their experience with this technique in 136 patients with craniopharyngiomas. From the past 7 years 204 patients with different purely supradiaphragmatic tumors underwent removal by extended endoscopic transsphenoidal transtuberculum transplanum approach. Most of the patients (136) had craniopharyngiomas (suprasellar, intra-extraventricular). The patients were analyzed according to age, sex, tumor size, growth and tumor structure, and clinical symptoms. Twenty-five patients had undergone a previous surgery. The mean follow-up was 42 months (range, 4-120 months). The operation is always performed with the bilateral endoscopic endonasal anterior extended transsphenoidal approach. A gross-total removal was completed in 72%. Improvement of vision or absence of visual deterioration after operation was observed in 89% of patients; 11% had worsening vision after surgery. Endocrine dysfunction did not improve after surgery, new hypotalamopituitary dysfunction (anterior pituitary dysfunction or diabetes insipidus) or worsening of it was observed in 42.6%. Other main complications included transient new mental disorder in 11%, temporary neurological postoperative deficits in 3.7%, bacterial meningitis in 16%, cerebrospinal fluid leaks in 8.8%. The recurrence rate was 20% and the lethality was 5.8%. Resection of suprasellar craniopharyngiomas using the extended endoscopic approach is a more effective and less traumatic technology, able to provide resection of the tumor along with high quality of life after surgery, and relatively rare postoperative complications and mortality. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Algorithm-Architecture Matching for Signal and Image Processing

    CERN Document Server

    Gogniat, Guy; Morawiec, Adam; Erdogan, Ahmet

    2011-01-01

    Advances in signal and image processing together with increasing computing power are bringing mobile technology closer to applications in a variety of domains like automotive, health, telecommunication, multimedia, entertainment and many others. The development of these leading applications, involving a large diversity of algorithms (e.g. signal, image, video, 3D, communication, cryptography) is classically divided into three consecutive steps: a theoretical study of the algorithms, a study of the target architecture, and finally the implementation. Such a linear design flow is reaching its li

  13. Multimodal Navigation in Endoscopic Transsphenoidal Resection of Pituitary Tumors using Image-based Vascular and Cranial Nerve Segmentation: A Prospective Validation Study

    Science.gov (United States)

    Dolati, Parviz; Eichberg, Daniel; Golby, Alexandra; Zamani, Amir; Laws, Edward

    2016-01-01

    Introduction Transsphenoidal surgery (TSS) is a well-known approach for the treatment of pituitary tumors. However, lateral misdirection and vascular damage, intraoperative CSF leakage, and optic nerve and vascular injuries are all well-known complications, and the risk of adverse events is more likely in less experienced hands. This prospective study was conducted to validate the accuracy of image-based segmentation in localization of neurovascular structures during TSS. Methods Twenty-five patients with pituitary tumors underwent preoperative 3TMRI, which included thin-sectioned 3D space T2, 3D Time of Flight and MPRAGE sequences. Images were reviewed by an expert independent neuroradiologist. Imaging sequences were loaded in BrainLab iPlanNet (16/25 cases) or Stryker (9/25 cases) image guidance platforms for segmentation and pre-operative planning. After patient registration into the neuronavigation system and subsequent surgical exposure, each segmented neural or vascular element was validated by manual placement of the navigation probe on or as close as possible to the target. The audible pulsations of the bilateral ICA were confirmed using a micro-Doppler probe. Results Pre-operative segmentation of the ICA and cavernous sinus matched with the intra-operative endoscopic and micro-Doppler findings in all cases (Dice Similarity Coefficient =1). This information reassured the surgeons with regard to the lateral extent of bone removal at the sellar floor and the limits of lateral exploration. Excellent correspondence between image-based segmentation and the endoscopic view was also evident at the surface of the tumor and at the tumor-normal gland interfaces. This assisted in preventing unnecessary removal of the normal pituitary gland. Image-guidance assisted the surgeons in localizing the optic nerve and chiasm in 64% of the cases and the diaphragma sella in 52% of cases, which helped to determine the limits of upward exploration and to decrease the risk of CSF

  14. Autonomous vision networking: miniature wireless sensor networks with imaging technology

    Science.gov (United States)

    Messinger, Gioia; Goldberg, Giora

    2006-09-01

    The recent emergence of integrated PicoRadio technology, the rise of low power, low cost, System-On-Chip (SOC) CMOS imagers, coupled with the fast evolution of networking protocols and digital signal processing (DSP), created a unique opportunity to achieve the goal of deploying large-scale, low cost, intelligent, ultra-low power distributed wireless sensor networks for the visualization of the environment. Of all sensors, vision is the most desired, but its applications in distributed sensor networks have been elusive so far. Not any more. The practicality and viability of ultra-low power vision networking has been proven and its applications are countless, from security, and chemical analysis to industrial monitoring, asset tracking and visual recognition, vision networking represents a truly disruptive technology applicable to many industries. The presentation discusses some of the critical components and technologies necessary to make these networks and products affordable and ubiquitous - specifically PicoRadios, CMOS imagers, imaging DSP, networking and overall wireless sensor network (WSN) system concepts. The paradigm shift, from large, centralized and expensive sensor platforms, to small, low cost, distributed, sensor networks, is possible due to the emergence and convergence of a few innovative technologies. Avaak has developed a vision network that is aided by other sensors such as motion, acoustic and magnetic, and plans to deploy it for use in military and commercial applications. In comparison to other sensors, imagers produce large data files that require pre-processing and a certain level of compression before these are transmitted to a network server, in order to minimize the load on the network. Some of the most innovative chemical detectors currently in development are based on sensors that change color or pattern in the presence of the desired analytes. These changes are easily recorded and analyzed by a CMOS imager and an on-board DSP processor

  15. Outcomes after endoscopic port surgery for spontaneous intracerebral hematomas.

    Science.gov (United States)

    Ochalski, Pawel; Chivukula, Srinivas; Shin, Samuel; Prevedello, Daniel; Engh, Johnathan

    2014-05-01

    Spontaneous intracerebral hemorrhages (ICHs) cause significant morbidity and mortality. Traditional open surgical management strategies offer limited benefit except for the most superficial hemorrhages in select patients. Recent reports suggest that endoscopic approaches may improve outcomes, particularly for deep subcortical hemorrhages. However, the management of these patients remains controversial. We reviewed our experience using endoscopic port surgery to identify characteristics that may predict acceptable outcomes. We completed a retrospective chart and imaging review of patients who underwent endoscopic port surgery for evacuation of spontaneous ICH at a single center. Data were gathered regarding patient demographics, hemorrhage locations, operative findings, and clinical outcomes. From 2007 to 2011, 18 patients underwent evacuation of spontaneous intracerebral hematomas using an endoscopic port. The mean age in years was 62 years (range, 43-84 years). Six of 18 patients (33%) died before discharge, and 2 others (11%) died after at least 1 month of survival. Of 12 initial survivors, all were discharged to a rehabilitation or nursing facility. Complete hematoma evacuation was achieved in 7 of 18 patients, with the remaining 11 having a partial evacuation. The patients who died (n = 6) before discharge were statistically more likely to have a left-sided hemorrhage, partial evacuation, or older age than the survivors; death at least 1  month after evacuation was additionally associated with greater preoperative hematoma volumes. Our series demonstrates that endoscopic port surgery for acute intracerebral hematoma evacuation has the ability to achieve significant decompression of large and deep-seated hematomas. Patient age, extent of evacuation, laterality, and preoperative hematoma volume appear to influence patient outcome. Most overall outcomes remain poor. Future studies are necessary to determine if surgical evacuation is in fact superior to best

  16. Transparency-enhancing technology allows three-dimensional assessment of gastrointestinal mucosa: A porcine model.

    Science.gov (United States)

    Mizutani, Hiroya; Ono, Satoshi; Ushiku, Tetsuo; Kudo, Yotaro; Ikemura, Masako; Kageyama, Natsuko; Yamamichi, Nobutake; Fujishiro, Mitsuhiro; Someya, Takao; Fukayama, Masashi; Koike, Kazuhiko; Onodera, Hiroshi

    2018-02-01

    Although high-resolution three-dimensional imaging of endoscopically resected gastrointestinal specimens can help elucidating morphological features of gastrointestinal mucosa or tumor, there are no established methods to achieve this without breaking specimens apart. We evaluated the utility of transparency-enhancing technology for three-dimensional assessment of gastrointestinal mucosa in porcine models. Esophagus, stomach, and colon mucosa samples obtained from a sacrificed swine were formalin-fixed and paraffin-embedded, and subsequently deparaffinized for analysis. The samples were fluorescently stained, optically cleared using transparency-enhancing technology: ilLUmination of Cleared organs to IDentify target molecules method (LUCID), and visualized using laser scanning microscopy. After observation, all specimens were paraffin-embedded again and evaluated by conventional histopathological assessment to measure the impact of transparency-enhancing procedures. As a result, microscopic observation revealed horizontal section views of mucosa at deeper levels and enabled the three-dimensional image reconstruction of glandular and vascular structures. Besides, paraffin-embedded specimens after transparency-enhancing procedures were all assessed appropriately by conventional histopathological staining. These results suggest that transparency-enhancing technology may be feasible for clinical application and enable the three-dimensional structural analysis of endoscopic resected specimen non-destructively. Although there remain many limitations or problems to be solved, this promising technology might represent a novel histopathological method for evaluating gastrointestinal cancers. © 2018 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  17. Endoscopic partial medial maxillectomy with mucosal flap for maxillary sinus mucoceles.

    Science.gov (United States)

    Durr, Megan L; Goldberg, Andrew N

    2014-01-01

    To describe a technique of endoscopic medial maxillectomy with mucosal flap for postoperative maxillary sinus mucoceles and to present a case series of subjects who underwent this procedure. This case series includes four subjects with postoperative maxillary sinus mucoceles who underwent resection via endoscopic partial medial maxillectomy with a mucosal flap. We will discuss the clinical presentation, imaging characteristics, operative details, and outcomes. Four subjects are included in this study. The average age at the time of medial maxillectomy was 52 years (range 35-65 years). Three subjects (75%) were female. One subject (25%) had bilateral postoperative maxillary sinus mucoceles. Two subjects (50%) had unilateral right sided mucoceles, and the remaining subject had a unilateral left sided mucocele. All subjects had a history of multiple sinus procedures for chronic sinusitis including Caldwell-Luc procedures ipsilateral to the postoperative mucocele. All subjects underwent endoscopic medial maxillectomy without complication and were symptom free at the last follow up appointment, average 24 months (range 3-71 months) after medial maxillectomy. For postoperative maxillary sinus mucoceles in locations that are difficult to access via the middle meatus antrostomy, we recommend endoscopic medial maxillectomy with mucosal flap. Our preliminary experience with four subjects demonstrates complete resolution of symptoms after this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Real-time Image Processing for Microscopy-based Label-free Imaging Flow Cytometry in a Microfluidic Chip.

    Science.gov (United States)

    Heo, Young Jin; Lee, Donghyeon; Kang, Junsu; Lee, Keondo; Chung, Wan Kyun

    2017-09-14

    Imaging flow cytometry (IFC) is an emerging technology that acquires single-cell images at high-throughput for analysis of a cell population. Rich information that comes from high sensitivity and spatial resolution of a single-cell microscopic image is beneficial for single-cell analysis in various biological applications. In this paper, we present a fast image-processing pipeline (R-MOD: Real-time Moving Object Detector) based on deep learning for high-throughput microscopy-based label-free IFC in a microfluidic chip. The R-MOD pipeline acquires all single-cell images of cells in flow, and identifies the acquired images as a real-time process with minimum hardware that consists of a microscope and a high-speed camera. Experiments show that R-MOD has the fast and reliable accuracy (500 fps and 93.3% mAP), and is expected to be used as a powerful tool for biomedical and clinical applications.

  19. Transanal endoscopic microsurgery versus endoscopic mucosal resection for large rectal adenomas (TREND-study)

    NARCIS (Netherlands)

    van den Broek, Frank J. C.; de Graaf, Eelco J. R.; Dijkgraaf, Marcel G. W.; Haringsma, Jelle; Timmer, Robin; Weusten, Bas L. A. M.; Gerhards, Michael F.; Consten, Esther C. J.; Schwartz, Matthijs P.; Boom, Maarten J.; Derksen, Erik J.; Bijnen, A. Bart; Davids, Paul H. P.; Hoff, Christiaan; van Dullemen, Hendrik M.; Heine, G. Dimitri N.; van der Linde, Klaas; Jansen, Jeroen M.; Mallant-Hent, Rosalie C. H.; Breumelhof, Ronald; Geldof, Han; Hardwick, James C. H.; Doornebosch, Pascal G.; Depla, Annekatrien C. T. M.; Ernst, Miranda F.; van Munster, Ivo P.; de Hingh, Ignace H. J. T.; Schoon, Erik J.; Bemelman, Willem A.; Fockens, Paul; Dekker, Evelien; Reitsma, J.

    2009-01-01

    Background: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require

  20. [Endoscopic full-thickness resection].

    Science.gov (United States)

    Meier, B; Schmidt, A; Caca, K

    2016-08-01

    Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.

  1. Folate receptor overexpression can be visualized in real time during pituitary adenoma endoscopic transsphenoidal surgery with near-infrared imaging.

    Science.gov (United States)

    Lee, John Y K; Cho, Steve S; Zeh, Ryan; Pierce, John T; Martinez-Lage, Maria; Adappa, Nithin D; Palmer, James N; Newman, Jason G; Learned, Kim O; White, Caitlin; Kharlip, Julia; Snyder, Peter; Low, Philip S; Singhal, Sunil; Grady, M Sean

    2017-08-25

    OBJECTIVE Pituitary adenomas account for approximately 10% of intracranial tumors and have an estimated prevalence of 15%-20% in the general US population. Resection is the primary treatment for pituitary adenomas, and the transsphenoidal approach remains the most common. The greatest challenge with pituitary adenomas is that 20% of patients develop tumor recurrence. Current approaches to reduce recurrence, such as intraoperative MRI, are costly, associated with high false-positive rates, and not recommended. Pituitary adenomas are known to overexpress folate receptor alpha (FRα), and it was hypothesized that OTL38, a folate analog conjugated to a near-infrared (NIR) fluorescent dye, could provide real-time intraoperative visual contrast of the tumor versus the surrounding nonneoplastic tissues. The preliminary results of this novel clinical trial are presented. METHODS Nineteen adult patients who presented with pituitary adenoma were enrolled. Patients were infused with OTL38 2-4 hours prior to surgery. A 4-mm endoscope with both visible and NIR light capabilities was used to visualize the pituitary adenoma and its margins in real time during surgery. The signal-to-background ratio (SBR) was recorded for each tumor and surrounding tissues at various endoscope-to-sella distances. Immunohistochemical analysis was performed to assess the FRα expression levels in all specimens and classify patients as having either high or low FRα expression. RESULTS Data from 15 patients (4 with null cell adenomas, 1 clinically silent gonadotroph, 1 totally silent somatotroph, 5 with a corticotroph, 3 with somatotrophs, and 1 somatocorticotroph) were analyzed in this preliminary analysis. Four patients were excluded for technical considerations. Intraoperative NIR imaging delineated the main tumors in all 15 patients with an average SBR of 1.9 ± 0.70. The FRα expression level of the adenomas and endoscope-to-sella distance had statistically significant impacts on the fluorescent

  2. Auto-Scaling of Geo-Based Image Processing in an OpenStack Cloud Computing Environment

    Directory of Open Access Journals (Sweden)

    Sanggoo Kang

    2016-08-01

    Full Text Available Cloud computing is a base platform for the distribution of large volumes of data and high-performance image processing on the Web. Despite wide applications in Web-based services and their many benefits, geo-spatial applications based on cloud computing technology are still developing. Auto-scaling realizes automatic scalability, i.e., the scale-out and scale-in processing of virtual servers in a cloud computing environment. This study investigates the applicability of auto-scaling to geo-based image processing algorithms by comparing the performance of a single virtual server and multiple auto-scaled virtual servers under identical experimental conditions. In this study, the cloud computing environment is built with OpenStack, and four algorithms from the Orfeo toolbox are used for practical geo-based image processing experiments. The auto-scaling results from all experimental performance tests demonstrate applicable significance with respect to cloud utilization concerning response time. Auto-scaling contributes to the development of web-based satellite image application services using cloud-based technologies.

  3. Cholangiocarcinoma in Magnetic Resonance Cholangiopancreatography and Fascioliasis in Endoscopic Ultrasonography

    Directory of Open Access Journals (Sweden)

    Amir Houshang Mohammad Alizadeh

    2011-10-01

    Full Text Available Fascioliasis is a worldwide zoonotic infection with Fasciola hepatica and Fasciola gigantica. The zoonoses are particularly endemic in sheep-raising countries and are also endemic in Iran. Typical symptoms that may be associated with fascioliasis can be divided by phases of the disease, including the acute or liver phase, the chronic or biliary phase, and ectopic or pharyngeal fascioliasis. Cholestatic symptoms may be absent, and in some cases diagnosis and treatment may be preceded by a long period of abdominal pain, eosinophilia and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 4 years, with imaging suggesting cholangiocarcinoma. Considering a new concept of endoscopic ultrasonography, at last F. hepatica was extracted with endoscopic retrograde cholangiography.

  4. Endoscopic full-thickness resection: Current status.

    Science.gov (United States)

    Schmidt, Arthur; Meier, Benjamin; Caca, Karel

    2015-08-21

    Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.

  5. Outcomes After Conservative, Endoscopic, and Surgical Treatment of Groove Pancreatitis: A Systematic Review.

    Science.gov (United States)

    Kager, Liesbeth M; Lekkerkerker, Selma J; Arvanitakis, Marianna; Delhaye, Myriam; Fockens, Paul; Boermeester, Marja A; van Hooft, Jeanin E; Besselink, Marc G

    2017-09-01

    Groove pancreatitis (GP) is a focal form of chronic pancreatitis affecting the paraduodenal groove area, for which consensus on diagnosis and management is lacking. We performed a systematic review of the literature to determine patient characteristics and imaging features of GP and to evaluate clinical outcomes after treatment. Eight studies were included reporting on 335 GP patients with a median age of 47 years (range, 34 to 64 y), with 90% male, 87% smokers, and 87% alcohol consumption, and 47 months (range, 15 to 122 mo) of follow-up. Most patients presented with abdominal pain (91%) and/or weight loss (78%). Imaging frequently showed cystic lesions (91%) and duodenal stenosis (60%).Final treatment was conservative (eg, pain medication) in 29% of patients. Endoscopic treatment (eg, pseudocyst drainage) was applied in 19% of patients-34% of these patients were subsequently referred for surgery. Overall, 59% of patients were treated surgically (eg, pancreatoduodenectomy). Complete symptom relief was observed in 50% of patients who were treated conservatively, 57% who underwent endoscopic treatment, and 79% who underwent surgery. GP is associated with male gender, smoking, and alcohol consumption. The vast majority of patients presents with abdominal pain and with cystic lesions on imaging. Although surgical treatment seems to be the most effective, both conservative and endoscopic treatment are successful in about half of patients. A stepwise treatment algorithm starting with the least invasive treatment options seems advisable.

  6. Novel methods for endoscopic training.

    Science.gov (United States)

    Gessner, C E; Jowell, P S; Baillie, J

    1995-04-01

    The development of past, present, and future endoscopic training methods is described. A historical perspective of endoscopy training guidelines and devices is used to demonstrate support for the use of novel endoscopic training techniques. Computer simulation of endoscopy, interactive learning, and virtual reality applications in endoscopy and surgery are reviewed. The goals of endoscopic simulation and challenges facing investigators in this field are discussed, with an emphasis on current and future research.

  7. State of the art in advanced endoscopic imaging for the detection and evaluation of dysplasia and early cancer of the gastrointestinal tract

    Directory of Open Access Journals (Sweden)

    Coda S

    2014-05-01

    Full Text Available Sergio Coda,1,2 Andrew V Thillainayagam1,2 1Section of Gastroenterology and Hepatology, Department of Medicine and Photonics Group, Department of Physics, Imperial College London, London, UK; 2Endoscopy Unit, Charing Cross Hospital, Imperial College Healthcare NHS Trust, London, UK Abstract: Ideally, endoscopists should be able to detect, characterize, and confirm the nature of a lesion at the bedside, minimizing uncertainties and targeting biopsies and resections only where necessary. However, under conventional white-light inspection – at present, the sole established technique available to most of humanity – premalignant conditions and early cancers can frequently escape detection. In recent years, a range of innovative techniques have entered the endoscopic arena due to their ability to enhance the contrast of diseased tissue regions beyond what is inherently possible with standard white-light endoscopy equipment. The aim of this review is to provide an overview of the state-of-the-art advanced endoscopic imaging techniques available for clinical use that are impacting the way precancerous and neoplastic lesions of the gastrointestinal tract are currently detected and characterized at endoscopy. The basic instrumentation and the physics behind each method, followed by the most influential clinical experience, are described. High-definition endoscopy, with or without optical magnification, has contributed to higher detection rates compared with white-light endoscopy alone and has now replaced ordinary equipment in daily practice. Contrast-enhancement techniques, whether dye-based or computed, have been combined with white-light endoscopy to further improve its accuracy, but histology is still required to clarify the diagnosis. Optical microscopy techniques such as confocal laser endomicroscopy and endocytoscopy enable in vivo histology during endoscopy; however, although of invaluable assistance for tissue characterization, they have not

  8. Peroral endoscopic myotomy: An emerging minimally invasive procedure for achalasia

    Science.gov (United States)

    Vigneswaran, Yalini; Ujiki, Michael B

    2015-01-01

    Peroral endoscopic myotomy (POEM) is an emerging minimally invasive procedure for the treatment of achalasia. Due to the improvements in endoscopic technology and techniques, this procedure allows for submucosal tunneling to safely endoscopically create a myotomy across the hypertensive lower esophageal sphincter. In the hands of skilled operators and experienced centers, the most common complications of this procedure are related to insufflation and accumulation of gas in the chest and abdominal cavities with relatively low risks of devastating complications such as perforation or delayed bleeding. Several centers worldwide have demonstrated the feasibility of this procedure in not only early achalasia but also other indications such as redo myotomy, sigmoid esophagus and spastic esophagus. Short-term outcomes have showed great clinical efficacy comparable to laparoscopic Heller myotomy (LHM). Concerns related to postoperative gastroesophageal reflux remain, however several groups have demonstrated comparable clinical and objective measures of reflux to LHM. Although long-term outcomes are necessary to better understand durability of the procedure, POEM appears to be a promising new procedure. PMID:26468336

  9. Suitable post processing algorithms for X-ray imaging using oversampled displaced multiple images

    International Nuclear Information System (INIS)

    Thim, J; Reza, S; Nawaz, K; Norlin, B; O'Nils, M; Oelmann, B

    2011-01-01

    X-ray imaging systems such as photon counting pixel detectors have a limited spatial resolution of the pixels, based on the complexity and processing technology of the readout electronics. For X-ray imaging situations where the features of interest are smaller than the imaging system pixel size, and the pixel size cannot be made smaller in the hardware, alternative means of resolution enhancement require to be considered. Oversampling with the usage of multiple displaced images, where the pixels of all images are mapped to a final resolution enhanced image, has proven a viable method of reaching a sub-pixel resolution exceeding the original resolution. The effectiveness of the oversampling method declines with the number of images taken, the sub-pixel resolution increases, but relative to a real reduction of imaging pixel sizes yielding a full resolution image, the perceived resolution from the sub-pixel oversampled image is lower. This is because the oversampling method introduces blurring noise into the mapped final images, and the blurring relative to full resolution images increases with the oversampling factor. One way of increasing the performance of the oversampling method is by sharpening the images in post processing. This paper focus on characterizing the performance increase of the oversampling method after the use of some suitable post processing filters, for digital X-ray images specifically. The results show that spatial domain filters and frequency domain filters of the same type yield indistinguishable results, which is to be expected. The results also show that the effectiveness of applying sharpening filters to oversampled multiple images increase with the number of images used (oversampling factor), leaving 60-80% of the original blurring noise after filtering a 6 x 6 mapped image (36 images taken), where the percentage is depending on the type of filter. This means that the effectiveness of the oversampling itself increase by using sharpening

  10. Overview of CMOS process and design options for image sensor dedicated to space applications

    Science.gov (United States)

    Martin-Gonthier, P.; Magnan, P.; Corbiere, F.

    2005-10-01

    With the growth of huge volume markets (mobile phones, digital cameras...) CMOS technologies for image sensor improve significantly. New process flows appear in order to optimize some parameters such as quantum efficiency, dark current, and conversion gain. Space applications can of course benefit from these improvements. To illustrate this evolution, this paper reports results from three technologies that have been evaluated with test vehicles composed of several sub arrays designed with some space applications as target. These three technologies are CMOS standard, improved and sensor optimized process in 0.35μm generation. Measurements are focussed on quantum efficiency, dark current, conversion gain and noise. Other measurements such as Modulation Transfer Function (MTF) and crosstalk are depicted in [1]. A comparison between results has been done and three categories of CMOS process for image sensors have been listed. Radiation tolerance has been also studied for the CMOS improved process in the way of hardening the imager by design. Results at 4, 15, 25 and 50 krad prove a good ionizing dose radiation tolerance applying specific techniques.

  11. Implicit prosody mining based on the human eye image capture technology

    Science.gov (United States)

    Gao, Pei-pei; Liu, Feng

    2013-08-01

    The technology of eye tracker has become the main methods of analyzing the recognition issues in human-computer interaction. Human eye image capture is the key problem of the eye tracking. Based on further research, a new human-computer interaction method introduced to enrich the form of speech synthetic. We propose a method of Implicit Prosody mining based on the human eye image capture technology to extract the parameters from the image of human eyes when reading, control and drive prosody generation in speech synthesis, and establish prosodic model with high simulation accuracy. Duration model is key issues for prosody generation. For the duration model, this paper put forward a new idea for obtaining gaze duration of eyes when reading based on the eye image capture technology, and synchronous controlling this duration and pronunciation duration in speech synthesis. The movement of human eyes during reading is a comprehensive multi-factor interactive process, such as gaze, twitching and backsight. Therefore, how to extract the appropriate information from the image of human eyes need to be considered and the gaze regularity of eyes need to be obtained as references of modeling. Based on the analysis of current three kinds of eye movement control model and the characteristics of the Implicit Prosody reading, relative independence between speech processing system of text and eye movement control system was discussed. It was proved that under the same text familiarity condition, gaze duration of eyes when reading and internal voice pronunciation duration are synchronous. The eye gaze duration model based on the Chinese language level prosodic structure was presented to change previous methods of machine learning and probability forecasting, obtain readers' real internal reading rhythm and to synthesize voice with personalized rhythm. This research will enrich human-computer interactive form, and will be practical significance and application prospect in terms of

  12. High Throughput Multispectral Image Processing with Applications in Food Science.

    Directory of Open Access Journals (Sweden)

    Panagiotis Tsakanikas

    Full Text Available Recently, machine vision is gaining attention in food science as well as in food industry concerning food quality assessment and monitoring. Into the framework of implementation of Process Analytical Technology (PAT in the food industry, image processing can be used not only in estimation and even prediction of food quality but also in detection of adulteration. Towards these applications on food science, we present here a novel methodology for automated image analysis of several kinds of food products e.g. meat, vanilla crème and table olives, so as to increase objectivity, data reproducibility, low cost information extraction and faster quality assessment, without human intervention. Image processing's outcome will be propagated to the downstream analysis. The developed multispectral image processing method is based on unsupervised machine learning approach (Gaussian Mixture Models and a novel unsupervised scheme of spectral band selection for segmentation process optimization. Through the evaluation we prove its efficiency and robustness against the currently available semi-manual software, showing that the developed method is a high throughput approach appropriate for massive data extraction from food samples.

  13. High Throughput Multispectral Image Processing with Applications in Food Science.

    Science.gov (United States)

    Tsakanikas, Panagiotis; Pavlidis, Dimitris; Nychas, George-John

    2015-01-01

    Recently, machine vision is gaining attention in food science as well as in food industry concerning food quality assessment and monitoring. Into the framework of implementation of Process Analytical Technology (PAT) in the food industry, image processing can be used not only in estimation and even prediction of food quality but also in detection of adulteration. Towards these applications on food science, we present here a novel methodology for automated image analysis of several kinds of food products e.g. meat, vanilla crème and table olives, so as to increase objectivity, data reproducibility, low cost information extraction and faster quality assessment, without human intervention. Image processing's outcome will be propagated to the downstream analysis. The developed multispectral image processing method is based on unsupervised machine learning approach (Gaussian Mixture Models) and a novel unsupervised scheme of spectral band selection for segmentation process optimization. Through the evaluation we prove its efficiency and robustness against the currently available semi-manual software, showing that the developed method is a high throughput approach appropriate for massive data extraction from food samples.

  14. Potentialities of the X-ray endoscopic diagnosis of stomach syphilis

    International Nuclear Information System (INIS)

    Dmitrieva, S.D.; Gurova, S.V.; Kovalenko, S.F.; Popova, G.N.; Legostaev, V.M.

    1999-01-01

    The possibilities of roentgenoendoscopic diagnostics of stomach syphilis are demonstrated by disease cases. Three forms of the stomach syphilis: tumor-like, infiltration and ulcerous ones are identified both roentgenological and endoscopic. Any infiltration process in the stomach of a young patient determined roentgenological should be reasoned as a sign of alterness relative to the syphilis. To perform endoscopic diagnosis of the stomach syphilis is easier than roentgenological one. The final syphilis diagnosis is impossible without blood test [ru

  15. Combined transnasal and transoral endoscopic approach to a transsphenoidal encephalocele in an infant.

    Science.gov (United States)

    Tan, Sien Hui; Mun, Kein Seong; Chandran, Patricia Ann; Manuel, Anura Michelle; Prepageran, Narayanan; Waran, Vicknes; Ganesan, Dharmendra

    2015-07-01

    This paper reports an unusual case of a transsphenoidal encephalocele and discusses our experience with a minimally invasive management. To the best of our knowledge, we present the first case of a combined endoscopic transnasal and transoral approach to a transsphenoidal encephalocele in an infant. A 17-day-old boy, who was referred for further assessment of upper airway obstruction, presented with respiratory distress and feeding difficulties. Bronchoscopy and imaging revealed a transsphenoidal encephalocele. At the age of 48 days, he underwent a combined endoscopic transnasal and transoral excision of the nasal component of the encephalocele. This approach, with the aid of neuronavigation, allows good demarcation of the extra-cranial neck of the transsphenoidal encephalocele. We were able to cauterize and carefully dissect the sac prior to excision. The defect of the neck was clearly visualized, and Valsalva manoeuvre was performed to exclude any CSF leak. As the defect was small, it was allowed to heal by secondary intention. The patient's recovery was uneventful, and he tolerated full feeds orally on day 2. Postoperative imaging demonstrated no evidence of recurrence of the nasal encephalocele. Endoscopic follow-up showed good healing of the mucosa and no cerebrospinal fluid leak. The surgical management of transsphenoidal encephalocele in neonates and infants is challenging. We describe a safe technique with low morbidity in managing such a condition. The combined endoscopic transnasal and transoral approach with neuronavigation is a minimally invasive, safe and feasible alternative, even for children below 1 year of age.

  16. Medical imaging technology

    CERN Document Server

    Haidekker, Mark A

    2013-01-01

    Biomedical imaging is a relatively young discipline that started with Conrad Wilhelm Roentgen’s discovery of the x-ray in 1885. X-ray imaging was rapidly adopted in hospitals around the world. However, it was the advent of computerized data and image processing that made revolutionary new imaging modalities possible. Today, cross-sections and three-dimensional reconstructions of the organs inside the human body is possible with unprecedented speed, detail and quality. This book provides an introduction into the principles of image formation of key medical imaging modalities: X-ray projection imaging, x-ray computed tomography, magnetic resonance imaging, ultrasound imaging, and radionuclide imaging. Recent developments in optical imaging are also covered. For each imaging modality, the introduction into the physical principles and sources of contrast is provided, followed by the methods of image formation, engineering aspects of the imaging devices, and a discussion of strengths and limitations of the modal...

  17. Endoscopic medial maxillectomy breaking new frontiers.

    Science.gov (United States)

    Mohanty, Sanjeev; Gopinath, M

    2013-07-01

    Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management of benign sino-nasal tumours. We present our experience of endoscopic medial maxillectomy in the management of sinonasal pathologies.

  18. Endoscopic management of bleeding peptic ulcers

    International Nuclear Information System (INIS)

    Farooqi, J.I.; Farooqi, R.J.

    2001-01-01

    Peptic ulcers account for more than half of the cases of non variceal upper gastrointestinal (GI) bleeding and therefore, are the focus of most of the methods of endoscopic hemostasis. Surgical intervention is now largely reserved for patients in whom endoscopic hemostasis has failed. A variety of endoscopic techniques have been employed to stop bleeding and reduce the risk of rebleeding, with no major differences in outcome between these methods. These include injection therapy, fibrin injection, heater probe, mono polar electrocautery, bipolar electrocautery, lasers and mechanical hemo clipping. The most important factor in determining outcome after gastrointestinal bleeding is rebleeding or persistent bleeding. The endoscopic appearance of an ulcer, however, provides the most useful prognostic information for bleeding. Recurrent bleeding after initial endoscopic hemostasis occurs in 15-20% of patients with a bleeding peptic ulcer. The best approach to these patients remains controversial; the current options are repeat endoscopic therapy with the same or a different technique, emergency surgery or semi elective surgery after repeat endoscopic hemostasis. The combination of epinephrine injection with thermal coagulation may be more effective than epinephrine injection alone. Newer modalities such as fibrin injection or the application of hemo clips appear promising and comparative studies are awaited. (author)

  19. Image processing with ImageJ

    CERN Document Server

    Pascau, Javier

    2013-01-01

    The book will help readers discover the various facilities of ImageJ through a tutorial-based approach.This book is targeted at scientists, engineers, technicians, and managers, and anyone who wishes to master ImageJ for image viewing, processing, and analysis. If you are a developer, you will be able to code your own routines after you have finished reading this book. No prior knowledge of ImageJ is expected.

  20. Clinical evaluation of endoscopic trimodal imaging for the detection and differentiation of colonic polyps.

    Science.gov (United States)

    van den Broek, Frank J C; Fockens, Paul; Van Eeden, Susanne; Kara, Mohammed A; Hardwick, James C H; Reitsma, Johannes B; Dekker, Evelien

    2009-03-01

    Endoscopic trimodal imaging (ETMI) incorporates high-resolution endoscopy (HRE) and autofluorescence imaging (AFI) for adenoma detection, and narrow-band imaging (NBI) for differentiation of adenomas from nonneoplastic polyps. The aim of this study was to compare AFI with HRE for adenoma detection and to assess the diagnostic accuracy of NBI for differentiation of polyps. This was a randomized trial of tandem colonoscopies. The study was performed at the Academic Medical Center in Amsterdam. One hundred patients underwent colonoscopy with ETMI. Each colonic segment was examined twice for polyps, once with HRE and once with AFI, in random order per patient. All detected polyps were assessed with NBI for pit pattern and with AFI for color, and subsequently removed. Histopathology served as the gold standard for diagnosis. The main outcome measures of this study were adenoma miss-rates of AFI and HRE, and diagnostic accuracy of NBI and AFI for differentiating adenomas from nonneoplastic polyps. Among 50 patients examined with AFI first, 32 adenomas were detected initially. Subsequent inspection with HRE identified 8 additional adenomas. Among 50 patients examined with HRE first, 35 adenomas were detected initially. Successive AFI yielded 14 additional adenomas. The adenoma miss-rates of AFI and HRE therefore were 20% and 29%, respectively (P = .351). The sensitivity, specificity, and overall accuracy of NBI for differentiation were 90%, 70%, and 79%, respectively; corresponding figures for AFI were 99%, 35%, and 63%, respectively. The overall adenoma miss-rate was 25%; AFI did not significantly reduce the adenoma miss-rate compared with HRE. Both NBI and AFI had a disappointing diagnostic accuracy for polyp differentiation, although AFI had a high sensitivity.

  1. Per-oral endoscopic myotomy: Major advance in achalasia treatment and in endoscopic surgery

    Science.gov (United States)

    Friedel, David; Modayil, Rani; Stavropoulos, Stavros N

    2014-01-01

    Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis. PMID:25548473

  2. Endoscopic tissue diagnosis of cholangiocarcinoma.

    LENUS (Irish Health Repository)

    Harewood, Gavin C

    2008-09-01

    The extremely poor outcome in patients with cholangiocarcinoma, in large part, reflects the late presentation of these tumors and the challenging nature of establishing a tissue diagnosis. Establishing a diagnosis of cholangiocarcinoma requires obtaining evidence of malignancy from sampling of the epithelium of the biliary tract, which has proven to be challenging. Although endoscopic ultrasound-guided fine needle aspiration performs slightly better than endoscopic retrograde cholangiopancreatography in diagnosing cholangiocarcinoma, both endoscopic approaches demonstrate disappointing performance characteristics.

  3. Endoscopic repair of transsellar transsphenoidal meningoencephalocele; case report and review of approaches

    Directory of Open Access Journals (Sweden)

    Maryam Jalessi, M.D.

    2015-06-01

    Full Text Available We present an extremely rare case of transsellar transsphenoidal meningoencephalocele in a 36-year-old woman with pituitary dwarfism complaining of nasal obstruction. Imaging studies showed a bony defect in the sellar floor and sphenoid sinus with huge nasopharyngeal mass and 3rd ventricle involvement. Using endoscopic endonasal approach the sac was partially removed and the defect was reconstructed with fat and fascial graft, and buttressed with titanium mesh and septal flap. Visual field improvement was noticed post-operatively and no complication was encountered during follow-up. So, endoscopic endonasal approach with partial resection of the sac is a safe and effective treatment for this disease

  4. Papillary Ependymoma WHO Grade II of the Aqueduct Treated by Endoscopic Tumor Resection

    Directory of Open Access Journals (Sweden)

    Andreas M. Stark

    2009-01-01

    Full Text Available Papillary ependymoma is a rare tumor that may be located along the ventricular walls or within the spinal cord. We report the case of a 54-year-old patient with a papillary ependymoma WHO grade II arising at the entrance of the aqueduct. The tumor caused hydrocephalus. The tumor was completely removed via a right-sided endoscopic approach with restoration of the aqueduct. The free cerebrospinal fluid passage through the aqueduct was not only visualized by endoscopy but also controlled by intraoperative high-field magnetic resonance imaging. Therefore, an additional endoscopic third ventriculostomy was unneccessary.

  5. Development in Rubber Preparation for Endoscopic Training Simulator

    Directory of Open Access Journals (Sweden)

    D. Surangsrirat

    2016-01-01

    Full Text Available Endoscopy is one of the most important procedures in diagnosis and treatment of gastrointestinal tract problems. While endoscopic procedure has tremendous benefits, physicians require considerable practice and time to develop competency. Current endoscopic training process involves cognitive learning and hands-on training under the supervision of an expert gastroenterologist. Previous studies have shown that fellow involvement prolongs procedural time and incurs additional expenses to the institution. Moreover, the patient also experiences more discomfort and injury risk. Introduction of training simulator into the training process could reduce the involvement of the patients and thus reduce the risk. Porcine model is commonly used for training in endoscopy due to the similar tactile response to a human gastrointestinal tract. However, information on elastic behavior of pig or human gastrointestinal tract for the engineering purposes was limited. In this study, the modulus of elasticity and ultimate tensile stress data of the pig stomach and intestines, small and large intestines, were measured and compared with multiple rubber stomach and intestines models. Based on the experimental results and experienced gastroenterologists feedback, the proposed dipped rubber composition can provide a satisfactory tactile feedback and could be used to simulate a human gastrointestinal tract for an endoscopic simulation training model.

  6. TU-AB-202-12: A Novel Method to Map Endoscopic Video to CT for Treatment Planning and Toxicity Analysis in Radiation Therapy

    International Nuclear Information System (INIS)

    Ingram, W; Yang, J; Beadle, B; Wendt, R; Rao, A; Court, L

    2016-01-01

    Purpose: Endoscopic examinations are routine procedures for head-and-neck cancer patients. Our goal is to develop a method to map the recorded video to CT, providing valuable information for radiotherapy treatment planning and toxicity analysis. Methods: We map video frames to CT via virtual endoscopic images rendered at the real endoscope’s CT-space coordinates. We developed two complementary methods to find these coordinates by maximizing real-to-virtual image similarity:(1)Endoscope Tracking: moves the virtual endoscope frame-by-frame until the desired frame is reached. Utilizes prior knowledge of endoscope coordinates, but sensitive to local optima. (2)Location Search: moves the virtual endoscope along possible paths through the volume to find the desired frame. More robust, but more computationally expensive. We tested these methods on clay phantoms with embedded markers for point mapping and protruding bolus material for contour mapping, and we assessed them qualitatively on three patient exams. For mapped points we calculated 3D-distance errors, and for mapped contours we calculated mean absolute distances (MAD) from CT contours. Results: In phantoms, Endoscope Tracking had average point error=0.66±0.50cm and average bolus MAD=0.74±0.37cm for the first 80% of each video. After that the virtual endoscope got lost, increasing these values to 4.73±1.69cm and 4.06±0.30cm. Location Search had point error=0.49±0.44cm and MAD=0.53±0.28cm. Point errors were larger where the endoscope viewed the surface at shallow angles<10 degrees (1.38±0.62cm and 1.22±0.69cm for Endoscope Tracking and Location Search, respectively). In patients, Endoscope Tracking did not make it past the nasal cavity. However, Location Search found coordinates near the correct location for 70% of test frames. Its performance was best near the epiglottis and in the nasal cavity. Conclusion: Location Search is a robust and accurate technique to map endoscopic video to CT. Endoscope

  7. Impact of future technology on oncologic diagnosis: oncologic imaging and diagnosis

    International Nuclear Information System (INIS)

    Hendee, W.R.

    1983-01-01

    Over the past few years, the discipline of medical imaging has entered an evolutionary period that reflects primarily the introduction of computers and digital technology into the imaging process. Clinical applications of this evolution realized to date (e.g., transmission computed tomography, ultrasound and quantitative nuclear medicine) are only indicative of future developments that promise to increase the contributions of medical imaging in a very substantial manner. This increase in the area of oncologic diagnosis is one of the more exciting possibilities existing in medicine today

  8. Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology

    Energy Technology Data Exchange (ETDEWEB)

    Spink, C., E-mail: c.spink@uke.de [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Avanesov, M. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Schmidt, T. [Philips Healthcare, Hamburg (Germany); Grass, M. [Philips Research, Hamburg (Germany); Schoen, G. [Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany); Adam, G.; Bannas, P.; Koops, A. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg (Germany)

    2017-01-15

    Highlights: • The new imaging technology halved the radiation exposure. • DSA image quality observed was not decreased after technology upgrade. • Radiation time and contrast consumption not significantly increased using the new technology. - Abstract: Objective: To compare patient radiation dose in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) implantation before and after an imaging-processing technology upgrade. Methods: In our retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), total fluoroscopy time and contrast agent were collected from an age- and BMI-matched collective of 108 patients undergoing TIPS implantation. 54 procedures were performed before and 54 after the technology upgrade. Mean values were calculated and compared using two-tailed t-tests. Two blinded, independent readers assessed DSA image quality using a four-rank likert scale and the Wilcoxcon test. Results: The new technology demonstrated a significant reduction of 57% of mean DAP (402.8 vs. 173.3 Gycm{sup 2}, p < 0.001) and a significant reduction of 58% of mean AK (1.7 vs. 0.7 Gy, p < 0.001) compared to the precursor technology. Time of fluoroscopy (26.4 vs. 27.8 min, p = 0.45) and amount of contrast agent (109.4 vs. 114.9 ml, p = 0.62) did not differ significantly between the two groups. The DSA image quality of the new technology was not inferior (2.66 vs. 2.77, p = 0.56). Conclusions: In our study the new imaging technology halved radiation dose in patients undergoing TIPS maintaining sufficient image quality without a significant increase in radiation time or contrast consumption.

  9. Current Status of Peroral Endoscopic Myotomy

    Science.gov (United States)

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders. PMID:29397656

  10. Current Status of Peroral Endoscopic Myotomy.

    Science.gov (United States)

    Cho, Young Kwan; Kim, Seong Hwan

    2018-01-01

    Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.

  11. Current Status of Peroral Endoscopic Myotomy

    Directory of Open Access Journals (Sweden)

    Young Kwan Cho

    2018-01-01

    Full Text Available Peroral endoscopic myotomy (POEM has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.

  12. Trends in the electronic X-ray image formation and processing

    International Nuclear Information System (INIS)

    Meyer-Ebrecht, D.; Spiesberger, W.

    1976-01-01

    A report is given on the technological progress in components for the electronic imaging and reproduction in X-ray diagnostics which could enable the partial replacement of radiophotography. Furthermore, electronic post processing methods, in particular in tomography, are reviewed. (ORU) [de

  13. Semi-automated Digital Imaging and Processing System for Measuring Lake Ice Thickness

    Science.gov (United States)

    Singh, Preetpal

    Canada is home to thousands of freshwater lakes and rivers. Apart from being sources of infinite natural beauty, rivers and lakes are an important source of water, food and transportation. The northern hemisphere of Canada experiences extreme cold temperatures in the winter resulting in a freeze up of regional lakes and rivers. Frozen lakes and rivers tend to offer unique opportunities in terms of wildlife harvesting and winter transportation. Ice roads built on frozen rivers and lakes are vital supply lines for industrial operations in the remote north. Monitoring the ice freeze-up and break-up dates annually can help predict regional climatic changes. Lake ice impacts a variety of physical, ecological and economic processes. The construction and maintenance of a winter road can cost millions of dollars annually. A good understanding of ice mechanics is required to build and deem an ice road safe. A crucial factor in calculating load bearing capacity of ice sheets is the thickness of ice. Construction costs are mainly attributed to producing and maintaining a specific thickness and density of ice that can support different loads. Climate change is leading to warmer temperatures causing the ice to thin faster. At a certain point, a winter road may not be thick enough to support travel and transportation. There is considerable interest in monitoring winter road conditions given the high construction and maintenance costs involved. Remote sensing technologies such as Synthetic Aperture Radar have been successfully utilized to study the extent of ice covers and record freeze-up and break-up dates of ice on lakes and rivers across the north. Ice road builders often used Ultrasound equipment to measure ice thickness. However, an automated monitoring system, based on machine vision and image processing technology, which can measure ice thickness on lakes has not been thought of. Machine vision and image processing techniques have successfully been used in manufacturing

  14. Endoscopic resection of cavernoma of foramen of Monro in a patient with familial multiple cavernomatosis.

    Science.gov (United States)

    Prat, Ricardo; Galeano, Inmaculada

    2008-09-01

    Intraventricular cavernomas are extremely infrequent and only 11 cases of cavernous hemangioma to occur at the foramen of Monro have been reported in the literature. This 56 years old patient was admitted with progressive and intractable headache of 10 days of evolution. He was known to suffer familial multiple cavernomatosis. Magnetic resonance imaging (MRI), revealed obstructive hydrocephalus due to a cavernoma located in the area of the left foramen of Monro. Under neuronavigation guidance, complete endoscopic resection of the cavernoma was performed and normal ventricular size achieved. The patient experienced transient recent memory loss that resolved within a month after surgery. In the literature attempted endoscopic resection is reported to be abandoned due to bleeding and ineffectiveness of piecemeal endoscopic resection. In this case, the multiplicity of the lesions made it advisable to resect the lesion endoscopically, to avoid an open procedure in a patient with multiple potentially surgical lesions. Endoscopic resection was uneventful with easy control of bleeding with irrigation, suction, and bipolar coagulation despite dense vascular appearance of the lesion. During the procedure, precise visualization of the vascular structures around the foramen of Monro allowed complete resection with satisfactory control of the instruments. To the best of the authors' knowledge, this is the first published cavernoma of foramen of Monro successfully resected using an endoscopic approach.

  15. Transoral endoscopic esophageal myotomy based on esophageal function testing in a survival porcine model.

    Science.gov (United States)

    Perretta, Silvana; Dallemagne, Bernard; Donatelli, Gianfranco; Diemunsch, Pierre; Marescaux, Jacques

    2011-01-01

    The most effective treatment of achalasia is Heller myotomy. To explore a submucosal endoscopic myotomy technique tailored on esophageal physiology testing and to compare it with the open technique. Prospective acute and survival comparative study in pigs (n = 12; 35 kg). University animal research center. Eight acute-4 open and 4 endoscopic-myotomies followed by 4 survival endoscopic procedures. Preoperative and postoperative manometry; esophagogastric junction (EGJ) distensibility before and after selective division of muscular fibers at the EGJ and after the myotomy was prolonged to a standard length by using the EndoFLIP Functional Lumen Imaging Probe (Crospon, Galway, Ireland). All procedures were successful, with no intraoperative and postoperative complications. In the survival group, the animals recovered promptly from surgery. Postoperative manometry demonstrated a 50% drop in mean lower esophageal sphincter pressure (LESp) in the endoscopic group (mean preoperative LESp, 22.2 ± 3.3 mm Hg; mean postoperative LESp, 11.34 ± 2.7 mm Hg; P open procedure group (mean preoperative LESp, 24.2 ± 3.2 mm Hg; mean postoperative LESp, 7.4 ± 4 mm Hg; P myotomy is feasible and safe. The lack of a significant difference in EGJ distensibility between the open and endoscopic procedure is very appealing. Were it to be perfected in a human population, this endoscopic approach could suggest a new strategy in the treatment of selected achalasia patients. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.

  16. Hyperspectral image processing methods

    Science.gov (United States)

    Hyperspectral image processing refers to the use of computer algorithms to extract, store and manipulate both spatial and spectral information contained in hyperspectral images across the visible and near-infrared portion of the electromagnetic spectrum. A typical hyperspectral image processing work...

  17. 21 CFR 884.4100 - Endoscopic electrocautery and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endoscopic electrocautery and accessories. 884... Surgical Devices § 884.4100 Endoscopic electrocautery and accessories. (a) Identification. An endoscopic electrocautery is a device used to perform female sterilization under endoscopic observation. It is designed to...

  18. HD Photo: a new image coding technology for digital photography

    Science.gov (United States)

    Srinivasan, Sridhar; Tu, Chengjie; Regunathan, Shankar L.; Sullivan, Gary J.

    2007-09-01

    This paper introduces the HD Photo coding technology developed by Microsoft Corporation. The storage format for this technology is now under consideration in the ITU-T/ISO/IEC JPEG committee as a candidate for standardization under the name JPEG XR. The technology was developed to address end-to-end digital imaging application requirements, particularly including the needs of digital photography. HD Photo includes features such as good compression capability, high dynamic range support, high image quality capability, lossless coding support, full-format 4:4:4 color sampling, simple thumbnail extraction, embedded bitstream scalability of resolution and fidelity, and degradation-free compressed domain support of key manipulations such as cropping, flipping and rotation. HD Photo has been designed to optimize image quality and compression efficiency while also enabling low-complexity encoding and decoding implementations. To ensure low complexity for implementations, the design features have been incorporated in a way that not only minimizes the computational requirements of the individual components (including consideration of such aspects as memory footprint, cache effects, and parallelization opportunities) but results in a self-consistent design that maximizes the commonality of functional processing components.

  19. Smartphones as image processing systems for prosthetic vision.

    Science.gov (United States)

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  20. Imaging and image restoration of an on-axis three-mirror Cassegrain system with wavefront coding technology.

    Science.gov (United States)

    Guo, Xiaohu; Dong, Liquan; Zhao, Yuejin; Jia, Wei; Kong, Lingqin; Wu, Yijian; Li, Bing

    2015-04-01

    Wavefront coding (WFC) technology is adopted in the space optical system to resolve the problem of defocus caused by temperature difference or vibration of satellite motion. According to the theory of WFC, we calculate and optimize the phase mask parameter of the cubic phase mask plate, which is used in an on-axis three-mirror Cassegrain (TMC) telescope system. The simulation analysis and the experimental results indicate that the defocused modulation transfer function curves and the corresponding blurred images have a perfect consistency in the range of 10 times the depth of focus (DOF) of the original TMC system. After digital image processing by a Wiener filter, the spatial resolution of the restored images is up to 57.14 line pairs/mm. The results demonstrate that the WFC technology in the TMC system has superior performance in extending the DOF and less sensitivity to defocus, which has great value in resolving the problem of defocus in the space optical system.

  1. Single-Blinded Prospective Implementation of a Preoperative Imaging Checklist for Endoscopic Sinus Surgery.

    Science.gov (United States)

    Error, Marc; Ashby, Shaelene; Orlandi, Richard R; Alt, Jeremiah A

    2018-01-01

    Objective To determine if the introduction of a systematic preoperative sinus computed tomography (CT) checklist improves identification of critical anatomic variations in sinus anatomy among patients undergoing endoscopic sinus surgery. Study Design Single-blinded prospective cohort study. Setting Tertiary care hospital. Subjects and Methods Otolaryngology residents were asked to identify critical surgical sinus anatomy on preoperative CT scans before and after introduction of a systematic approach to reviewing sinus CT scans. The percentage of correctly identified structures was documented and compared with a 2-sample t test. Results A total of 57 scans were reviewed: 28 preimplementation and 29 postimplementation. Implementation of the sinus CT checklist improved identification of critical sinus anatomy from 24% to 84% correct ( P identification of sinus anatomic variants, including those not directly included in the systematic review implemented. Conclusion The implementation of a preoperative endoscopic sinus surgery radiographic checklist improves identification of critical anatomic sinus variations in a training population.

  2. Waste processing building with incineration technology

    Science.gov (United States)

    Wasilah, Wasilah; Zaldi Suradin, Muh.

    2017-12-01

    In Indonesia, waste problem is one of major problem of the society in the city as part of their life dynamics. Based on Regional Medium Term Development Plan of South Sulawesi Province in 2013-2018, total volume and waste production from Makassar City, Maros, Gowa, and Takalar Regency estimates the garbage dump level 9,076.949 m3/person/day. Additionally, aim of this design is to present a recommendation on waste processing facility design that would accommodate waste processing process activity by incineration technology and supported by supporting activity such as place of education and research on waste, and the administration activity on waste processing facility. Implementation of incineration technology would reduce waste volume up to 90% followed by relative negative impact possibility. The result planning is in form of landscape layout that inspired from the observation analysis of satellite image line pattern of planning site and then created as a building site pattern. Consideration of building orientation conducted by wind analysis process and sun path by auto desk project Vasari software. The footprint designed by separate circulation system between waste management facility interest and the social visiting activity in order to minimize the croos and thus bring convenient to the building user. Building mass designed by inseparable connection series system, from the main building that located in the Northward, then connected to a centre visitor area lengthways, and walked to the waste processing area into the residue area in the Southward area.

  3. Development of Auto-Seeding System Using Image Processing Technology in the Sapphire Crystal Growth Process via the Kyropoulos Method

    Directory of Open Access Journals (Sweden)

    Churl Min Kim

    2017-04-01

    Full Text Available The Kyropoulos (Ky and Czochralski (Cz methods of crystal growth are used for large-diameter single crystals. The seeding process in these methods must induce initial crystallization by initiating contact between the seed crystals and the surface of the melted material. In the Ky and Cz methods, the seeding process lays the foundation for ingot growth during the entire growth process. When any defect occurs in this process, it is likely to spread to the entire ingot. In this paper, a vision system was constructed for auto seeding and for observing the surface of the melt in the Ky method. An algorithm was developed to detect the time when the internal convection of the melt is stabilized by observing the shape of the spoke pattern on the melt material surface. Then, the vision system and algorithm were applied to the growth furnace, and the possibility of process automation was examined for sapphire growth. To confirm that the convection of the melt was stabilized, the position of the island (i.e., the center of a spoke pattern was detected using the vision system and image processing. When the observed coordinates for the center of the island were compared with the coordinates detected from the image processing algorithm, there was an average error of 1.87 mm (based on an image with 1024 × 768 pixels.

  4. Endoscopic management of hilar biliary strictures

    Science.gov (United States)

    Singh, Rajiv Ranjan; Singh, Virendra

    2015-01-01

    Hilar biliary strictures are caused by various benign and malignant conditions. It is difficult to differentiate benign and malignant strictures. Postcholecystectomy benign biliary strictures are frequently encountered. Endoscopic management of these strictures is challenging. An endoscopic method has been advocated that involves placement of increasing number of stents at regular intervals to resolve the stricture. Malignant hilar strictures are mostly unresectable at the time of diagnosis and only palliation is possible.Endoscopic palliation is preferred over surgery or radiological intervention. Magnetic resonance cholangiopancreaticography is quite important in the management of these strictures. Metal stents are superior to plastic stents. The opinion is divided over the issue of unilateral or bilateral stenting.Minimal contrast or no contrast technique has been advocated during endoscopic retrograde cholangiopancreatography of these patients. The role of intraluminal brachytherapy, intraductal ablation devices, photodynamic therapy, and endoscopic ultrasound still remains to be defined. PMID:26191345

  5. Ultrahigh speed endoscopic optical coherence tomography for gastroenterology.

    Science.gov (United States)

    Tsai, Tsung-Han; Lee, Hsiang-Chieh; Ahsen, Osman O; Liang, Kaicheng; Giacomelli, Michael G; Potsaid, Benjamin M; Tao, Yuankai K; Jayaraman, Vijaysekhar; Figueiredo, Marisa; Huang, Qin; Cable, Alex E; Fujimoto, James; Mashimo, Hiroshi

    2014-12-01

    We describe an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor imaging catheter. The system had a 600 kHz axial scan rate and 8 µm axial resolution in tissue. Imaging was performed with a 3.2 mm diameter imaging catheter at 400 frames per second with a 12 µm spot size. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing upper and lower endoscopy. The use of distally actuated imaging catheters enabled OCT imaging with more flexibility, such as volumetric imaging in the small intestine and the assessment of hiatal hernia using retroflex imaging. The high rotational scanning stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face OCT and cross-sectional imaging, as well as OCT angiography (OCTA) for 3D visualization of subsurface microvasculature. The ability to perform both structural and functional 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies and enhance the sensitivity and specificity of OCT for detecting pathology.

  6. Automatic detection of NIL defects using microscopy and image processing

    KAUST Repository

    Pietroy, David

    2013-12-01

    Nanoimprint Lithography (NIL) is a promising technology for low cost and large scale nanostructure fabrication. This technique is based on a contact molding-demolding process, that can produce number of defects such as incomplete filling, negative patterns, sticking. In this paper, microscopic imaging combined to a specific processing algorithm is used to detect numerically defects in printed patterns. Results obtained for 1D and 2D imprinted gratings with different microscopic image magnifications are presented. Results are independent on the device which captures the image (optical, confocal or electron microscope). The use of numerical images allows the possibility to automate the detection and to compute a statistical analysis of defects. This method provides a fast analysis of printed gratings and could be used to monitor the production of such structures. © 2013 Elsevier B.V. All rights reserved.

  7. Imaging in the Evaluation of Endoscopic or Surgical Treatment for Achalasia

    OpenAIRE

    Diego Palladino; Andrea Mardighian; Marilina D’Amora; Luca Roberto; Francesco Lassandro; Claudia Rossi; Gianluca Gatta; Mariano Scaglione; Guglielmi Giuseppe

    2016-01-01

    Purpose. Aim of the study is to evaluate the efficacy of the endoscopic (pneumatic dilation) versus surgical (Heller myotomy) treatment in patients affected by esophageal achalasia using barium X-ray examination of the digestive tract performed before and after the treatment. Materials and Methods. 19 patients (10 males and 9 females) were enrolled in this study; each patient underwent a barium X-ray examination to evaluate the esophageal diameter and the height of the barium column before a...

  8. Endoscopic transmission of Helicobacter pylori

    NARCIS (Netherlands)

    Tytgat, G. N.

    1995-01-01

    The contamination of endoscopes and biopsy forceps with Helicobacter pylori occurs readily after endoscopic examination of H. pylori-positive patients. Unequivocal proof of iatrogenic transmission of the organism has been provided. Estimates for transmission frequency approximate to 4 per 1000

  9. Benchmarking, Research, Development, and Support for ORNL Automated Image and Signature Retrieval (AIR/ASR) Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, K.W.

    2004-06-01

    This report describes the results of a Cooperative Research and Development Agreement (CRADA) with Applied Materials, Inc. (AMAT) of Santa Clara, California. This project encompassed the continued development and integration of the ORNL Automated Image Retrieval (AIR) technology, and an extension of the technology denoted Automated Signature Retrieval (ASR), and other related technologies with the Defect Source Identification (DSI) software system that was under development by AMAT at the time this work was performed. In the semiconductor manufacturing environment, defect imagery is used to diagnose problems in the manufacturing line, train yield management engineers, and examine historical data for trends. Image management in semiconductor data systems is a growing cause of concern in the industry as fabricators are now collecting up to 20,000 images each week. In response to this concern, researchers at the Oak Ridge National Laboratory (ORNL) developed a semiconductor-specific content-based image retrieval method and system, also known as AIR. The system uses an image-based query-by-example method to locate and retrieve similar imagery from a database of digital imagery using visual image characteristics. The query method is based on a unique architecture that takes advantage of the statistical, morphological, and structural characteristics of image data, generated by inspection equipment in industrial applications. The system improves the manufacturing process by allowing rapid access to historical records of similar events so that errant process equipment can be isolated and corrective actions can be quickly taken to improve yield. The combined ORNL and AMAT technology is referred to hereafter as DSI-AIR and DSI-ASR.

  10. Engineering aspects of a fully mirrored endoscope

    International Nuclear Information System (INIS)

    Terra, A.; Huber, A.; Schweer, B.; Mertens, Ph.; Arnoux, G.; Balshaw, N.; Brezinsek, S.; Egner, S.; Hartl, M.; Kampf, D.; Klammer, J.; Lambertz, H.T.; Morlock, C.; Murari, A.; Reindl, M.; Sanders, S.; Sergienko, G.; Spencer, G.

    2013-01-01

    Highlights: ► Replacement of JET diagnostics to match the new ITER-like Wall. ► The endoscope test ITER-like design with only mirror based optics. ► Withstanding and diagnostic capability during Plasma operation and disruptions. ► Engineering process from design to installation and procurement. -- Abstract: The development of optical diagnostics, like endoscopes, compatible with the ITER environment (metallic plasma facing components, neutron proof optics, etc.) is a challenge, but current tokamaks such as JET provide opportunities to test fully working concepts. This paper describes the engineering aspects of a fully mirrored endoscope that has recently been designed, procured and installed on JET. The system must operate in a very strict environment with high temperature, high magnetic fields up to B = 4 T and rapid field variations (∂B/∂t ∼ 100 T/s) that induce high stresses due to eddy currents in the front mirror assembly. It must be designed to withstand high mechanical loads especially during disruptions, which lead to acceleration of about 7 g at 14 Hz. For the JET endoscope, when the plasma thermal loading, direct and indirect, was added to the assumed disruption loads, the reserve factor, defined as a ratio of yield strength over summed up von Mises stresses, was close to 1 for the mirror components. To ensure reliable operation, several analyses were performed to evaluate the thermo-mechanical performance of the endoscope and a final validation was obtained from mechanical and thermal tests, before the system's final installation in May 2011. During the tests, stability of the field of view angle variation was kept below 1° despite the high thermal gradient on endoscope head (∂T/∂x ∼ 500 K/m). In parallel, to ensure long time operation and to prevent undesirable performance degradation, a shutter system was also implemented in order to reduce impurity deposition on in-vessel mirrors but also to allow in situ transmission calibration

  11. Image Processing for Quality Inspection of Mango Fruit

    OpenAIRE

    Ahmad, Usman

    2002-01-01

    Indonesia has many kinds of tropical fruits, including mango, that can be exported besides to suplly the demand on the fruits in the country. To ensure the quality of mango, it is important to do sortation and grading on them, especially those for export, based on the quality requirement. In this case, the use of high technology such as image processing in necesary to put into practise with the aim to increase the consistance of sortation and grading processes as compare to the result of manu...

  12. Storage, access, and retrieval of endoscopic and laparoscopic video

    Science.gov (United States)

    Bellaire, Gunter; Steines, Daniel; Graschew, Georgi; Thiel, Andreas; Bernarding, Johannes; Tolxdorff, Thomas; Schlag, Peter M.

    1999-05-01

    The system presented here enhances documentation and data- secured, second-opinion facilities by integrating video into DICOM3.0. Digital stereoscopic video sequences (DSVS) are especially in demand for surgery (laparoscopy, microsurgery, surgical microscopy, second opinion, virtual reality). Therefore DSVS are also integrated into the DICOM video concept. We present an implementation for a medical video server extended by a DICOM interface. Security mechanisms conforming with DICOM are integrated to enable secure internet access. Digital (stereoscopic) video sequences relevant for surgery should be examined regarding the clip length necessary for diagnosis and documentation and the clip size manageable with today's hardware. Methods for DSVS compression are described, implemented, and tested. Image sources relevant for this paper include, among others, a stereoscopic laparoscope and a monoscopic endoscope. Additionally, an approach is presented to analyze the motion of the endoscopic camera for future automatic video- cutting.

  13. Preclinical cadaveric study of transanal endoscopic da Vinci® surgery.

    Science.gov (United States)

    Hompes, R; Rauh, S M; Hagen, M E; Mortensen, N J

    2012-08-01

    Single-port platforms are increasingly being used for transanal surgery and may be associated with a shorter learning curve than transanal endoscopic microsurgery. However, these procedures remain technically challenging, and robotic technology could overcome some of the limitations and increase intraluminal manoeuvrability. An initial experimental experience with transanal endoscopic da Vinci(®) surgery (TEdS) using a glove port on human cadavers is reported. After initial dry laboratory experiments, the feasibility of TEdS and ideal set-up were further evaluated in human cadavers. For transanal access a glove port was constructed on-table by using a circular anal dilator, a standard wound retractor and a surgical glove. A da Vinci(®) Si HD system was used in combination with the glove port for transanal endoscopic resections. It was possible to perform all necessary tasks to complete a full-thickness excision and closure of the rectal wall, with cadavers in both prone and supine positions. The stable magnified view, combined with the EndoWrist(®) technology of the robotic instruments, made every task straightforward. Intraluminal manoeuvrability could be improved further by intersecting the robotic instruments. The glove port proved to be very reliable and the inherent flexibility of the glove facilitated docking of the robotic arms in a narrow confined space. Using a reliable and universally available glove port, TEdS was feasible and a preferred set-up was determined. Further clinical trials will be necessary to assess the safety and efficacy of this technique. Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  14. The role of multi-detector-row computed tomograph in the diagnosis of intraductal papillary-mucinous tumors of the pancreas in comparison to endoscopic retrograde pancreatography, endoscopic ultrasonography, magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Arikawa, Shunji; Uchida, Masafumi; Shinagawa, Masaharu

    2007-01-01

    Thirty patients with intraductal papillary-mucinous tumor (IPMT) of the pancreas underwent multidetector-row CT (MD-CT) in addition to endoscopic retrograde pancreatography (ERP), and, in 27 cases magnetic resonance cholangiopancreatography (MRCP) and endoscopic ultrasonography (EUS). The usefulness of MD-CT was investigated by comparing various imaging methods of the communication from the main pancreatic duct (MPD) to patulous/bulging papilla in addition to the indices for benign or malignant disease, the degree of dilation of the MPD, localization and size of cystic lesions, and presence or absence of neoplastic lesions, such as thickened walls and septa, intramural nodule, solid mass. With MD-CT, dilation of the MPD and localization and size of cystic lesions were accurately assessed, even in patients with obstruction of the main pancreatic duct in whom ERP was difficult to perform regardless of the presence or absence of massive amount of mucus. MD-CT with reconstructive imaging, such as multiplanar reformation (MPR) imaging and curred planar reformation (CPR) imaging, allowed us to assess communication with the MPD and patulous/bulging papilla easier than MRCP. In our study, MD-CT was useful in the evaluation of thickened walls and septa that are predictive factors of malignancy in IPMT. (author)

  15. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    Science.gov (United States)

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  16. Gynaecological Endoscopic Surgical Education and Assessment. A diploma programme in gynaecological endoscopic surgery.

    Science.gov (United States)

    Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon

    2016-04-01

    In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA), recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy; (b) the Minimally Invasive Gynaecological Surgeon (MIGS); and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence and it counteracts the problem of the traditional surgical apprentice tutor model. It is seen as a major step toward standardization of endoscopic surgical training in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Pre-operative assessment of patients undergoing endoscopic, transnasal, transsphenoidal pituitary surgery.

    Science.gov (United States)

    Lubbe, D; Semple, P

    2008-06-01

    To demonstrate the importance of pre-operative ear, nose and throat assessment in patients undergoing endoscopic, transsphenoidal surgery for pituitary tumours. Literature pertaining to the pre-operative otorhinolaryngological assessment and management of patients undergoing endoscopic anterior skull base surgery is sparse. We describe two cases from our series of 59 patients undergoing endoscopic pituitary surgery. The first case involved a young male patient with a large pituitary macroadenoma. His main complaint was visual impairment. He had no previous history of sinonasal pathology and did not complain of any nasal symptoms during the pre-operative neurosurgical assessment. At the time of surgery, a purulent nasal discharge was seen emanating from both middle meati. Surgery was abandoned due to the risk of post-operative meningitis, and postponed until the patient's chronic rhinosinusitis was optimally managed. The second patient was a 47-year-old woman with a large pituitary macroadenoma, who presented to the neurosurgical department with a main complaint of diplopia. She too gave no history of previous nasal problems, and she underwent uneventful surgery using the endoscopic, transnasal approach. Two weeks after surgery, she presented to the emergency unit with severe epistaxis. A previous diagnosis of hereditary haemorrhagic telangiectasia was discovered, and further surgical and medical intervention was required before the epistaxis was finally controlled. Pre-operative otorhinolaryngological assessment is essential prior to endoscopic pituitary or anterior skull base surgery. A thorough otorhinolaryngological history will determine whether any co-morbid diseases exist which could affect the surgical field. Nasal anatomy can be assessed via nasal endoscopy and sinusitis excluded. Computed tomography imaging is a valuable aid to decisions regarding additional procedures needed to optimise access to the pituitary fossa.

  18. Laser Imaging Facilitates Early Detection of Synchronous Adenocarcinomas in Patients with Barrett’s Esophagus

    Directory of Open Access Journals (Sweden)

    Chihiro Iwashita

    2017-01-01

    Full Text Available Barrett’s adenocarcinoma may occur in multiple sites, and recurrence and metachronous lesions are the major problems with endoscopic resection. Therefore, early detection of such lesions is ideal to achieve complete resection and obtain improved survival rates with minimally invasive treatment. Laser imaging systems allow multiple modalities of endoscopic imaging by using white light laser, flexible spectral imaging color enhancement (FICE, blue laser imaging (BLI, and linked color imaging even at a distant view. However, the usefulness of these modalities has not been sufficiently reported regarding Barrett’s adenocarcinoma. Here, we report on a patient with three synchronous lesions followed by one metachronous lesion in a long segment with changes of Barrett’s esophagus, all diagnosed with this new laser endoscopic imaging system and enhanced by using FICE and/or BLI with high contrast compared with the surrounding mucosa. Laser endoscopic imaging may facilitate the detection of malignancies in patients with early Barrett’s adenocarcinoma.

  19. Study progression in application of process analytical technologies on film coating

    Directory of Open Access Journals (Sweden)

    Tingting Peng

    2015-06-01

    Full Text Available Film coating is an important unit operation to produce solid dosage forms, thereby, the monitoring of this process is helpful to find problems in time and improve the quality of coated products. Traditional methods adopted to monitor this process include measurement of coating weight gain, performance of disintegration and dissolution test, etc. However, not only do these methods cause destruction to the samples, but also consume time and energy. There have recently emerged the applications of process analytical technologies (PAT on film coating, especially some novel spectroscopic and imaging technologies, which have the potential to real-time track the progress in film coating and optimize production efficiency. This article gives an overview on the application of such technologies for film coating, with the goal to provide a reference for the further researches.

  20. Grid Computing Application for Brain Magnetic Resonance Image Processing

    International Nuclear Information System (INIS)

    Valdivia, F; Crépeault, B; Duchesne, S

    2012-01-01

    This work emphasizes the use of grid computing and web technology for automatic post-processing of brain magnetic resonance images (MRI) in the context of neuropsychiatric (Alzheimer's disease) research. Post-acquisition image processing is achieved through the interconnection of several individual processes into pipelines. Each process has input and output data ports, options and execution parameters, and performs single tasks such as: a) extracting individual image attributes (e.g. dimensions, orientation, center of mass), b) performing image transformations (e.g. scaling, rotation, skewing, intensity standardization, linear and non-linear registration), c) performing image statistical analyses, and d) producing the necessary quality control images and/or files for user review. The pipelines are built to perform specific sequences of tasks on the alphanumeric data and MRIs contained in our database. The web application is coded in PHP and allows the creation of scripts to create, store and execute pipelines and their instances either on our local cluster or on high-performance computing platforms. To run an instance on an external cluster, the web application opens a communication tunnel through which it copies the necessary files, submits the execution commands and collects the results. We present result on system tests for the processing of a set of 821 brain MRIs from the Alzheimer's Disease Neuroimaging Initiative study via a nonlinear registration pipeline composed of 10 processes. Our results show successful execution on both local and external clusters, and a 4-fold increase in performance if using the external cluster. However, the latter's performance does not scale linearly as queue waiting times and execution overhead increase with the number of tasks to be executed.

  1. Recent Applications of Chemical Imaging to Pharmaceutical Process Monitoring and Quality Control

    OpenAIRE

    Gowen, A. A.; O'Donnell, Colm; Cullen, Patrick; Bell, S.

    2008-01-01

    Chemical Imaging (CI) is an emerging platform technology that integrates conventional imaging and spectroscopy to attain both spatial and spectral information from an object. Vibrational spectroscopic methods, such as Near Infrared (NIR) and Raman spectroscopy, combined with imaging are particularly useful for analysis of biological/pharmaceutical forms. The rapid, non-destructive and non-invasive features of CI mark its potential suitability as a process analytical tool for the pharmaceutica...

  2. Surgical outcome of tuberculous meningitis hydrocephalus treated by endoscopic third ventriculostomy: prognostic factors and postoperative neuroimaging for functional assessment of ventriculostomy.

    Science.gov (United States)

    Chugh, Ashish; Husain, Mazhar; Gupta, Rakesh K; Ojha, Bal K; Chandra, Anil; Rastogi, Manu

    2009-05-01

    Endoscopic third ventriculostomy (ETV) is increasingly being used as an alternative treatment for post-tuberculous meningitis (TBM) hydrocephalus. The aim of this study was to affirm the role of ETV in patients with TBM hydrocephalus and also to study the usefulness of cine phase-contrast MR imaging (cine MR imaging) for functional assessment of the ETV stoma. An additional goal was to identify factors that influence the outcome of ETV, so as to define patients with TBM hydrocephalus in whom ETV is warranted. Twenty-six patients with TBM hydrocephalus treated with ETV were evaluated clinically and with cine MR imaging postoperatively. The duration of follow-up ranged from 1 to 15 months. The authors evaluated flow void changes in the floor of the third ventricle and analyzed parameters from the preoperative data, which they then used as a basis for comparison between endoscopically successful and endoscopically unsuccessful cases. The overall success rate of ETV in TBM hydrocephalus was 73.1% in this case series. Cine MR imaging showed a sensitivity of 94.73% and specificity of 71.42% for the functional assessment of third ventriculostomy in these patients, with the efficacy being maintained during follow-up. The outcome of ETV showed a statistically significant correlation with the stage of illness and presence of intraoperative cisternal exudates. Although duration of symptoms and duration of preoperative antituberculous therapy (ATT) appeared to influence the outcome, their correlation with outcome was not statistically significant. Endoscopic third ventriculostomy should be considered as the first surgical option for CSF diversion (that is, before shunt surgery) in patients with TBM hydrocephalus. Cine MR imaging is a highly effective noninvasive tool for the postoperative functional assessment of stomata. Patients who presented with a history of longer duration and those who were administered preoperative ATT for a longer period had a better outcome of

  3. Endoscopic Medial Maxillectomy Breaking New Frontiers

    OpenAIRE

    Mohanty, Sanjeev; Gopinath, M.

    2011-01-01

    Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management ...

  4. Modification of endoscopic medial maxillectomy: a novel approach for inverted papilloma of the maxillary sinus.

    Science.gov (United States)

    Ghosh, A; Pal, S; Srivastava, A; Saha, S

    2015-02-01

    To describe modification to endoscopic medial maxillectomy for treating extensive Krouse stage II or III inverted papilloma of the nasal and maxillary sinus. Ten patients with inverted papilloma arising from the nasoantral area underwent diagnostic nasal endoscopy, contrast-enhanced computed tomography scanning of the paranasal sinus and pre-operative biopsy of the nasal mass. They were all managed using endoscopic medial maxillectomy and followed up for seven months to three years without recurrence. Most patients were aged 41-60 years at presentation, and most were male. Presenting symptoms were nasal obstruction, mass in the nasal cavity and epistaxis. In each case, computed tomography imaging showed a mass involving the nasal cavity and maxillary sinus, with bony remodelling. The endoscopic medial maxillectomy approach was modified by making an incision in the pyriform aperture and removing part of the anterolateral wall of the maxilla bone en bloc. Modified endoscopic medial maxillectomy providing full access to the maxillary and ethmoid sinuses is described in detail. This effective, reproducible technique is associated with reduced operative time and morbidity.

  5. Development of preoperative planning software for transforaminal endoscopic surgery and the guidance for clinical applications.

    Science.gov (United States)

    Chen, Xiaojun; Cheng, Jun; Gu, Xin; Sun, Yi; Politis, Constantinus

    2016-04-01

    Preoperative planning is of great importance for transforaminal endoscopic techniques applied in percutaneous endoscopic lumbar discectomy. In this study, a modular preoperative planning software for transforaminal endoscopic surgery was developed and demonstrated. The path searching method is based on collision detection, and the oriented bounding box was constructed for the anatomical models. Then, image reformatting algorithms were developed for multiplanar reconstruction which provides detailed anatomical information surrounding the virtual planned path. Finally, multithread technique was implemented to realize the steady-state condition of the software. A preoperative planning software for transforaminal endoscopic surgery (TE-Guider) was developed; seven cases of patients with symptomatic lumbar disc herniations were planned preoperatively using TE-Guider. The distances to the midlines and the direction of the optimal paths were exported, and each result was in line with the empirical value. TE-Guider provides an efficient and cost-effective way to search the ideal path and entry point for the puncture. However, more clinical cases will be conducted to demonstrate its feasibility and reliability.

  6. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    Science.gov (United States)

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  7. Endoscopic management of intraoperative small bowel laceration during natural orifice translumenal endoscopic surgery: a blinded porcine study.

    Science.gov (United States)

    Fyock, Christopher J; Forsmark, Chris E; Wagh, Mihir S

    2011-01-01

    Natural orifice translumenal endoscopic surgery (NOTES) has recently gained great enthusiasm, but there is concern regarding the ability to endoscopically manage complications purely via natural orifices. To assess the feasibility of endoscopically managing enteral perforation during NOTES using currently available endoscopic accessories. Twelve pigs underwent transgastric or transcolonic endoscopic exploration. Full-thickness enterotomies were intentionally created to mimic accidental small bowel lacerations during NOTES. These lacerations were then closed with endoclips. In the blinded arm of the study, small bowel repair was performed by a second blinded endoscopist. Adequate closure of the laceration was confirmed with a leak test. Primary access sites were closed with endoclips or T-anchors. At necropsy, the peritoneal cavity was inspected for abscesses, bleeding, or damage to surrounding structures. The enterotomy site was examined for adequacy of closure, adhesions, or evidence of infection. Fifteen small bowel lacerations were performed in 12 animals. Successful closure was achieved in all 10 cases in the nonblinded arm. Survival animals had an uncomplicated postoperative course and all enterotomy sites were well healed without evidence of necrosis, adhesions, abscess, or bleeding at necropsy. Leak test was negative in all animals. In the blinded arm, both small intestinal lacerations could not be identified by the blinded endoscopist. Necropsy revealed open small bowel lacerations. Small intestinal injuries are difficult to localize with currently available flexible endoscopes and accessories. Endoscopic clips, however, may be adequate for closure of small bowel lacerations if the site of injury is known.

  8. using fuzzy logic in image processing

    International Nuclear Information System (INIS)

    Ashabrawy, M.A.F.

    2002-01-01

    due to the unavoidable merge between computer and mathematics, the signal processing in general and the processing in particular have greatly improved and advanced. signal processing deals with the processing of any signal data for use by a computer, while image processing deals with all kinds of images (just images). image processing involves the manipulation of image data for better appearance and viewing by people; consequently, it is a rapidly growing and exciting field to be involved in today . this work takes an applications - oriented approach to image processing .the applications; the maps and documents of the first egyptian research reactor (ETRR-1), the x-ray medical images and the fingerprints image. since filters, generally, work continuous ranges rather than discrete values, fuzzy logic techniques are more convenient.thee techniques are powerful in image processing and can deal with one- dimensional, 1-D and two - dimensional images, 2-D images as well

  9. Missile signal processing common computer architecture for rapid technology upgrade

    Science.gov (United States)

    Rabinkin, Daniel V.; Rutledge, Edward; Monticciolo, Paul

    2004-10-01

    Interceptor missiles process IR images to locate an intended target and guide the interceptor towards it. Signal processing requirements have increased as the sensor bandwidth increases and interceptors operate against more sophisticated targets. A typical interceptor signal processing chain is comprised of two parts. Front-end video processing operates on all pixels of the image and performs such operations as non-uniformity correction (NUC), image stabilization, frame integration and detection. Back-end target processing, which tracks and classifies targets detected in the image, performs such algorithms as Kalman tracking, spectral feature extraction and target discrimination. In the past, video processing was implemented using ASIC components or FPGAs because computation requirements exceeded the throughput of general-purpose processors. Target processing was performed using hybrid architectures that included ASICs, DSPs and general-purpose processors. The resulting systems tended to be function-specific, and required custom software development. They were developed using non-integrated toolsets and test equipment was developed along with the processor platform. The lifespan of a system utilizing the signal processing platform often spans decades, while the specialized nature of processor hardware and software makes it difficult and costly to upgrade. As a result, the signal processing systems often run on outdated technology, algorithms are difficult to update, and system effectiveness is impaired by the inability to rapidly respond to new threats. A new design approach is made possible three developments; Moore's Law - driven improvement in computational throughput; a newly introduced vector computing capability in general purpose processors; and a modern set of open interface software standards. Today's multiprocessor commercial-off-the-shelf (COTS) platforms have sufficient throughput to support interceptor signal processing requirements. This application

  10. Development Of An Atherothrombotic Occlusion In The Rabbit Carotid Artery: Accessed By New Computerized B- Mode Ultrasound Image Processing Technology And Histopathology

    Directory of Open Access Journals (Sweden)

    Hossein Mehrad

    2017-02-01

    Full Text Available Introduction: Thrombus formation on a disrupted atherosclerotic soft plaque is a key event that leads to atherothrombosis. Atherothrombosis is one of the leading causes of acute coronary syndrome and ischemic stroke. Our ability to test new protocols for the treatment of atherothrombotic stenosis in humans is limited for obvious ethical reasons; therefore, a precise understanding of the mechanism of atherothrombotic occlusion in human carotid artery, which give rise to thrombosis, emboli and stroke, requires a suitable animal model that would mimic the same characteristics well. Aims: The aim of this study was to generate an easily reproducible and inexpensive experimental rabbit carotid model of atherothrombotic occlusion with morphological similarities to the human disease and the subsequent assessment of the reliability of new computerized B- mode ultrasound image processing technology in the study of lumen area stenosis in this model. Methods: Briefly, male New Zealand white rabbits were submitted to common carotid artery atherothrombotic occlusion by primary balloon injury followed 1.5% cholesterol- rich diet injury for eight weeks and finally perivascularly severe cold injury. All of the rabbits' arteries were imaged by B-mode ultrasound weekly, after which the rabbits were sacrificed, and their vessels were processed for histopathology. Ultrasound longitudinal view images from three cardiac cycles were processed by a new computerized analyzing method based on dynamic programming and maximum gradient algorithm for measurement of instantaneous changes in arterial wall thickness and lumen diameter in sequential ultrasound images. Results: Histopathology results showed progressive changes, from the lipid-laden cells and fibrous connective tissue proliferation, fibrolipid plaque formation, resulting in vessel wall thickening, remodeling, neovascularization and lumen narrowing (before perivascularly severe cold injury using liquid nitrogen up

  11. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    Science.gov (United States)

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  12. An enhanced narrow-band imaging method for the microvessel detection

    Science.gov (United States)

    Yu, Feng; Song, Enmin; Liu, Hong; Wan, Youming; Zhu, Jun; Hung, Chih-Cheng

    2018-02-01

    A medical endoscope system combined with the narrow-band imaging (NBI), has been shown to be a superior diagnostic tool for early cancer detection. The NBI can reveal the morphologic changes of microvessels in the superficial cancer. In order to improve the conspicuousness of microvessel texture, we propose an enhanced NBI method to improve the conspicuousness of endoscopic images. To obtain the more conspicuous narrow-band images, we use the edge operator to extract the edge information of the narrow-band blue and green images, and give a weight to the extracted edges. Then, the weighted edges are fused with the narrow-band blue and green images. Finally, the displayed endoscopic images are reconstructed with the enhanced narrow-band images. In addition, we evaluate the performance of enhanced narrow-band images with different edge operators. Experimental results indicate that the Sobel and Canny operators achieve the best performance of all. Compared with traditional NBI method of Olympus company, our proposed method has more conspicuous texture of microvessel.

  13. Image recognition on raw and processed potato detection: a review

    Science.gov (United States)

    Qi, Yan-nan; Lü, Cheng-xu; Zhang, Jun-ning; Li, Ya-shuo; Zeng, Zhen; Mao, Wen-hua; Jiang, Han-lu; Yang, Bing-nan

    2018-02-01

    Objective: Chinese potato staple food strategy clearly pointed out the need to improve potato processing, while the bottleneck of this strategy is technology and equipment of selection of appropriate raw and processed potato. The purpose of this paper is to summarize the advanced raw and processed potato detection methods. Method: According to consult research literatures in the field of image recognition based potato quality detection, including the shape, weight, mechanical damage, germination, greening, black heart, scab potato etc., the development and direction of this field were summarized in this paper. Result: In order to obtain whole potato surface information, the hardware was built by the synchronous of image sensor and conveyor belt to achieve multi-angle images of a single potato. Researches on image recognition of potato shape are popular and mature, including qualitative discrimination on abnormal and sound potato, and even round and oval potato, with the recognition accuracy of more than 83%. Weight is an important indicator for potato grading, and the image classification accuracy presents more than 93%. The image recognition of potato mechanical damage focuses on qualitative identification, with the main affecting factors of damage shape and damage time. The image recognition of potato germination usually uses potato surface image and edge germination point. Both of the qualitative and quantitative detection of green potato have been researched, currently scab and blackheart image recognition need to be operated using the stable detection environment or specific device. The image recognition of processed potato mainly focuses on potato chips, slices and fries, etc. Conclusion: image recognition as a food rapid detection tool have been widely researched on the area of raw and processed potato quality analyses, its technique and equipment have the potential for commercialization in short term, to meet to the strategy demand of development potato as

  14. Methods of digital image processing

    International Nuclear Information System (INIS)

    Doeler, W.

    1985-01-01

    Increasing use of computerized methods for diagnostical imaging of radiological problems will open up a wide field of applications for digital image processing. The requirements set by routine diagnostics in medical radiology point to picture data storage and documentation and communication as the main points of interest for application of digital image processing. As to the purely radiological problems, the value of digital image processing is to be sought in the improved interpretability of the image information in those cases where the expert's experience and image interpretation by human visual capacities do not suffice. There are many other domains of imaging in medical physics where digital image processing and evaluation is very useful. The paper reviews the various methods available for a variety of problem solutions, and explains the hardware available for the tasks discussed. (orig.) [de

  15. Endoscopically assisted resection of a scapular osteochondroma causing snapping scapula syndrome

    Directory of Open Access Journals (Sweden)

    Futani Hiroyuki

    2007-03-01

    Full Text Available Abstract Background Osteochondroma is the most common benign bone tumor in the scapula. This condition might lead to snapping scapula syndrome, which is characterized by painful, audible, and/or palpable abnormal scapulothoracic motion. In the present case, this syndrome was successfully treated by use of endoscopically assisted resection of the osteochondroma. Case presentation A 41-year-old man had a tolerable pain in his scapular region over a 10 years' period. The pain developed gradually with shoulder motion, in particular with golf swing since he was aiming a professional golf player career. On physical examination, "clunking" was noted once from 90 degrees of abduction to 180 degrees of shoulder motion. A trans-scapular roentgenogram and computed tomography images revealed an osteochondroma located at the anterior and inferior aspect of the scapula. Removal of the tumor was performed by the use of endoscopically assisted resection. One portal was made at the lateral border of the scapula to introduce a 2.7-mm-diameter, 30 degrees Hopkins telescope. The tumor was resected in a piece-by-piece manner by the use of graspers through the same portal. Immediately after the operation pain relief was obtained, and the "clunking" disappeared. CT images showed complete tumor resection. The patient could start playing golf one week after the surgery. Conclusion Endoscopically assisted resection of osteochondroma of the scapula provides a feasible technique to treat snapping scapula syndrome and obtain early functional recovery with a short hospital stay and cosmetic advantage.

  16. How to change students' images of science and technology

    Science.gov (United States)

    Scherz, Zahava; Oren, Miri

    2006-11-01

    This paper examines the images middle school students have of science and technology, the workplaces, and the relevant professions. It also describes the effect on these images caused by an instructional initiative, Investigation into Science and Technology (IST), designed to introduce students to science and technology in the real life. Students' images were delineated via questionnaires, drawing tasks, and interviews before and after their participation in the IST program. The sample consisted of 100 students from six classes (eighth or ninth grade) of three schools. We found that before the IST intervention students' images about the scientific or technological environments were superficial, unreal, and even incorrect. Their impressions of the characteristics of scientists and technologists were superficial, misleading, and sometimes reflected ignorance. The findings demonstrate that the IST program stimulated a positive effect on students' images. Their preconceptions were altered in several dimensions: in the cognitive dimension, from superficial and vague to precise and correct images; in the perceptive dimension, from stereotypic to rational and open-minded images; and in the affective dimension, from negative to positive attitudes.

  17. Stable image acquisition for mobile image processing applications

    Science.gov (United States)

    Henning, Kai-Fabian; Fritze, Alexander; Gillich, Eugen; Mönks, Uwe; Lohweg, Volker

    2015-02-01

    Today, mobile devices (smartphones, tablets, etc.) are widespread and of high importance for their users. Their performance as well as versatility increases over time. This leads to the opportunity to use such devices for more specific tasks like image processing in an industrial context. For the analysis of images requirements like image quality (blur, illumination, etc.) as well as a defined relative position of the object to be inspected are crucial. Since mobile devices are handheld and used in constantly changing environments the challenge is to fulfill these requirements. We present an approach to overcome the obstacles and stabilize the image capturing process such that image analysis becomes significantly improved on mobile devices. Therefore, image processing methods are combined with sensor fusion concepts. The approach consists of three main parts. First, pose estimation methods are used to guide a user moving the device to a defined position. Second, the sensors data and the pose information are combined for relative motion estimation. Finally, the image capturing process is automated. It is triggered depending on the alignment of the device and the object as well as the image quality that can be achieved under consideration of motion and environmental effects.

  18. Can masses of non-experts train highly accurate image classifiers? A crowdsourcing approach to instrument segmentation in laparoscopic images.

    Science.gov (United States)

    Maier-Hein, Lena; Mersmann, Sven; Kondermann, Daniel; Bodenstedt, Sebastian; Sanchez, Alexandro; Stock, Christian; Kenngott, Hannes Gotz; Eisenmann, Mathias; Speidel, Stefanie

    2014-01-01

    Machine learning algorithms are gaining increasing interest in the context of computer-assisted interventions. One of the bottlenecks so far, however, has been the availability of training data, typically generated by medical experts with very limited resources. Crowdsourcing is a new trend that is based on outsourcing cognitive tasks to many anonymous untrained individuals from an online community. In this work, we investigate the potential of crowdsourcing for segmenting medical instruments in endoscopic image data. Our study suggests that (1) segmentations computed from annotations of multiple anonymous non-experts are comparable to those made by medical experts and (2) training data generated by the crowd is of the same quality as that annotated by medical experts. Given the speed of annotation, scalability and low costs, this implies that the scientific community might no longer need to rely on experts to generate reference or training data for certain applications. To trigger further research in endoscopic image processing, the data used in this study will be made publicly available.

  19. Fast processing of foreign fiber images by image blocking

    OpenAIRE

    Yutao Wu; Daoliang Li; Zhenbo Li; Wenzhu Yang

    2014-01-01

    In the textile industry, it is always the case that cotton products are constitutive of many types of foreign fibers which affect the overall quality of cotton products. As the foundation of the foreign fiber automated inspection, image process exerts a critical impact on the process of foreign fiber identification. This paper presents a new approach for the fast processing of foreign fiber images. This approach includes five main steps, image block, image pre-decision, image background extra...

  20. [Surveillance cultures after high-level disinfection of flexible endoscopes in a general hospital].

    Science.gov (United States)

    Robles, Christian; Turín, Christie; Villar, Alicia; Huerta-Mercado, Jorge; Samalvides, Frine

    2014-04-01

    Flexible endoscopes are instruments with a complex structure which are used in invasive gastroenterological procedures, therefore high-level disinfection (HLD) is recommended as an appropriate reprocessing method. However, most hospitals do not perform a quality control to assess the compliance and results of the disinfection process. To evaluate the effectiveness of the flexible endoscopes’ decontamination after high-level disinfection by surveillance cultures and to assess the compliance with the reprocessing guidelines. Descriptive study conducted in January 2013 in the Gastroenterological Unit of a tertiary hospital. 30 endoscopic procedures were randomly selected. Compliance with guidelines was evaluated and surveillance cultures for common bacteria were performed after the disinfection process. On the observational assessment, compliance with the guidelines was as follows: pre-cleaning 9 (30%), cleaning 5 (16.7%), rinse 3 (10%), first drying 30 (100%), disinfection 30 (100%), final rinse 0 (0%) and final drying 30 (100%), demonstrating that only 3 of 7 stages of the disinfection process were optimally performed. In the microbiological evaluation, 2 (6.7%) of the 30 procedures had a positive culture obtained from the surface of the endoscope. Furthermore, 1 (4.2%) of the 24 biopsy forcepsgave a positive culture. The organisms isolated were different Pseudomonas species. High-level disinfection procedures were not optimally performed, finding in 6.7% positive cultures of Pseudomonas species.

  1. Finding of biliary fascioliasis by endoscopic ultrasonography in a patient with eosinophilic liver abscess.

    Science.gov (United States)

    Behzad, Catherine; Lahmi, Farhad; Iranshahi, Majid; Mohammad Alizadeh, Amir Houshang

    2014-09-01

    Fascioliasis is an endemic zoonotic disease in Iran. It occurs mainly in sheep-rearing areas of temperate climates, but sporadic cases have been reported from many other parts of the world. The usual definitive host is the sheep. Humans are accidental hosts in the life cycle of Fasciola. Typical symptoms may be associated with fascioliasis, but in some cases diagnosis and treatment may be preceded by a long period of abdominal pain and vague gastrointestinal symptoms. We report a case with epigastric and upper quadrant abdominal pain for the last 6 months, with imaging suggesting liver abscess and normal biliary ducts. The patient had no eosinophilia with negative stool examinations, so she was initially treated with antibiotics for liver abscess. Her clinical condition as well as follow-up imagings showed appropriate response after antibiotic therapy. Finally, endoscopic ultrasonography revealed Fasciola hepatica, which was then extracted with endoscopic retrograde cholangiopancreatography.

  2. Effect of endoscopic transpapillary biliary drainage with/without endoscopic sphincterotomy on post-endoscopic retrograde cholangiopancreatography pancreatitis in patients with biliary stricture (E-BEST): a protocol for a multicentre randomised controlled trial.

    Science.gov (United States)

    Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya

    2017-08-11

    The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016-0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

    International Nuclear Information System (INIS)

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian

    2015-01-01

    Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was

  4. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion.

    Science.gov (United States)

    Luo, Xiongbiao; Wan, Ying; He, Xiangjian

    2015-04-01

    Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor's) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. The experimental results demonstrate that the authors' proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors' framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm

  5. Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xiongbiao, E-mail: xluo@robarts.ca, E-mail: Ying.Wan@student.uts.edu.au [Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Wan, Ying, E-mail: xluo@robarts.ca, E-mail: Ying.Wan@student.uts.edu.au; He, Xiangjian [School of Computing and Communications, University of Technology, Sydney, New South Wales 2007 (Australia)

    2015-04-15

    Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was

  6. Development of EndoTOFPET-US, a multi-modal endoscope for ultrasound and time of flight positron emission tomography

    International Nuclear Information System (INIS)

    Pizzichemi, M

    2014-01-01

    The EndoTOFPET-US project aims at delevoping a multi-modal imaging device that combines Ultrasound with Time-Of-Flight Positron Emission Tomography into an endoscopic imaging device. The goal is to obtain a coincidence time resolution of about 200 ps FWHM and sub-millimetric spatial resolution for the PET head, integrating the components in a very compact detector suitable for endoscopic use. The scanner will be exploited for the clinical test of new bio-markers especially targeted for prostate and pancreatic cancer as well as for diagnostic and surgical oncology. This paper focuses on the status of the Time-Of-Flight Positron Emission Tomograph under development for the EndoTOFPET-US project

  7. Endoscopic repair of an injured internal carotid artery utilizing femoral endovascular closure devices.

    Science.gov (United States)

    Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo

    2014-06-01

    Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Biomedical Image Processing

    CERN Document Server

    Deserno, Thomas Martin

    2011-01-01

    In modern medicine, imaging is the most effective tool for diagnostics, treatment planning and therapy. Almost all modalities have went to directly digital acquisition techniques and processing of this image data have become an important option for health care in future. This book is written by a team of internationally recognized experts from all over the world. It provides a brief but complete overview on medical image processing and analysis highlighting recent advances that have been made in academics. Color figures are used extensively to illustrate the methods and help the reader to understand the complex topics.

  9. An Unusual Endoscopic Image of a Submucosal Angiodysplasia

    Directory of Open Access Journals (Sweden)

    Rita Carvalho

    2012-01-01

    Full Text Available Obscure gastrointestinal bleeding is responsible for 2–10% of the cases of digestive bleeding. Angiodysplasia is the most common cause. The authors report a case of a 70-year-old female patient admitted to our Gastrointestinal Intensive Care Unit with a significant digestive bleeding. Standard upper and lower endoscopy showed no abnormalities, and we decided to perform a capsule enteroscopy that revealed a submucosal nodule with active bleeding in the jejunum. An intraoperative enteroscopy confirmed the presence of a small submucosal lesion with a central ulceration, and subsequently a segmental enterectomy was performed. Surprisingly, the histopathological diagnosis was angiodysplasia. The patient remains well after a two-year period of follow-up. We present this case of obscure/overt gastrointestinal bleeding to emphasize the role of capsule and intraoperative enteroscopy in the evaluation of these situations, and because of the unusual endoscopic appearance of the angiodysplasia responsible for the hemorrhage.

  10. New techniques in gastrointestinal endoscopic surgery

    Directory of Open Access Journals (Sweden)

    Rafael Antonio Luengas Tello

    2012-09-01

    Full Text Available Gastrointestinal endoscopic surgery has been making great progress since the seventies in the management paradigms of conditions such as gastrointestinal bleeding, polyp resection and diagnostic and therapeutic management of the biliary tract. The current challenge is the development of techniques that allow endoscopic treatment of emerging diseases such as cancer, morbid obesity, gastro-esophageal reflux and achalasia. This article reports on new techniques and expectations for the future in the endoscopic management of these diseases.

  11. Image perception and image processing

    International Nuclear Information System (INIS)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures. (orig.) [de

  12. Image perception and image processing

    Energy Technology Data Exchange (ETDEWEB)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures.

  13. Optoelectronic imaging of speckle using image processing method

    Science.gov (United States)

    Wang, Jinjiang; Wang, Pengfei

    2018-01-01

    A detailed image processing of laser speckle interferometry is proposed as an example for the course of postgraduate student. Several image processing methods were used together for dealing with optoelectronic imaging system, such as the partial differential equations (PDEs) are used to reduce the effect of noise, the thresholding segmentation also based on heat equation with PDEs, the central line is extracted based on image skeleton, and the branch is removed automatically, the phase level is calculated by spline interpolation method, and the fringe phase can be unwrapped. Finally, the imaging processing method was used to automatically measure the bubble in rubber with negative pressure which could be used in the tire detection.

  14. Introduction to digital image processing

    CERN Document Server

    Pratt, William K

    2013-01-01

    CONTINUOUS IMAGE CHARACTERIZATION Continuous Image Mathematical Characterization Image RepresentationTwo-Dimensional SystemsTwo-Dimensional Fourier TransformImage Stochastic CharacterizationPsychophysical Vision Properties Light PerceptionEye PhysiologyVisual PhenomenaMonochrome Vision ModelColor Vision ModelPhotometry and ColorimetryPhotometryColor MatchingColorimetry ConceptsColor SpacesDIGITAL IMAGE CHARACTERIZATION Image Sampling and Reconstruction Image Sampling and Reconstruction ConceptsMonochrome Image Sampling SystemsMonochrome Image Reconstruction SystemsColor Image Sampling SystemsImage QuantizationScalar QuantizationProcessing Quantized VariablesMonochrome and Color Image QuantizationDISCRETE TWO-DIMENSIONAL LINEAR PROCESSING Discrete Image Mathematical Characterization Vector-Space Image RepresentationGeneralized Two-Dimensional Linear OperatorImage Statistical CharacterizationImage Probability Density ModelsLinear Operator Statistical RepresentationSuperposition and ConvolutionFinite-Area Superp...

  15. A 45 nm Stacked CMOS Image Sensor Process Technology for Submicron Pixel.

    Science.gov (United States)

    Takahashi, Seiji; Huang, Yi-Min; Sze, Jhy-Jyi; Wu, Tung-Ting; Guo, Fu-Sheng; Hsu, Wei-Cheng; Tseng, Tung-Hsiung; Liao, King; Kuo, Chin-Chia; Chen, Tzu-Hsiang; Chiang, Wei-Chieh; Chuang, Chun-Hao; Chou, Keng-Yu; Chung, Chi-Hsien; Chou, Kuo-Yu; Tseng, Chien-Hsien; Wang, Chuan-Joung; Yaung, Dun-Nien

    2017-12-05

    A submicron pixel's light and dark performance were studied by experiment and simulation. An advanced node technology incorporated with a stacked CMOS image sensor (CIS) is promising in that it may enhance performance. In this work, we demonstrated a low dark current of 3.2 e - /s at 60 °C, an ultra-low read noise of 0.90 e - ·rms, a high full well capacity (FWC) of 4100 e - , and blooming of 0.5% in 0.9 μm pixels with a pixel supply voltage of 2.8 V. In addition, the simulation study result of 0.8 μm pixels is discussed.

  16. Ultrahigh speed endoscopic swept source optical coherence tomography using a VCSEL light source and micromotor catheter

    Science.gov (United States)

    Tsai, Tsung-Han; Ahsen, Osman O.; Lee, Hsiang-Chieh; Liang, Kaicheng; Giacomelli, Michael G.; Potsaid, Benjamin M.; Tao, Yuankai K.; Jayaraman, Vijaysekhar; Kraus, Martin F.; Hornegger, Joachim; Figueiredo, Marisa; Huang, Qin; Mashimo, Hiroshi; Cable, Alex E.; Fujimoto, James G.

    2014-03-01

    We developed an ultrahigh speed endoscopic swept source optical coherence tomography (OCT) system for clinical gastroenterology using a vertical-cavity surface-emitting laser (VCSEL) and micromotor based imaging catheter, which provided an imaging speed of 600 kHz axial scan rate and 8 μm axial resolution in tissue. The micromotor catheter was 3.2 mm in diameter and could be introduced through the 3.7 mm accessory port of an endoscope. Imaging was performed at 400 frames per second with an 8 μm spot size using a pullback to generate volumetric data over 16 mm with a pixel spacing of 5 μm in the longitudinal direction. Three-dimensional OCT (3D-OCT) imaging was performed in patients with a cross section of pathologies undergoing standard upper and lower endoscopy at the Veterans Affairs Boston Healthcare System (VABHS). Patients with Barrett's esophagus, dysplasia, and inflammatory bowel disease were imaged. The use of distally actuated imaging catheters allowed OCT imaging with more flexibility such as volumetric imaging in the terminal ileum and the assessment of the hiatal hernia using retroflex imaging. The high rotational stability of the micromotor enabled 3D volumetric imaging with micron scale volumetric accuracy for both en face and cross-sectional imaging. The ability to perform 3D OCT imaging in the GI tract with microscopic accuracy should enable a wide range of studies to investigate the ability of OCT to detect pathology as well as assess treatment response.

  17. Rare-earth-doped materials with application to optical signal processing, quantum information science, and medical imaging technology

    Science.gov (United States)

    Cone, R. L.; Thiel, C. W.; Sun, Y.; Böttger, Thomas; Macfarlane, R. M.

    2012-02-01

    Unique spectroscopic properties of isolated rare earth ions in solids offer optical linewidths rivaling those of trapped single atoms and enable a variety of recent applications. We design rare-earth-doped crystals, ceramics, and fibers with persistent or transient "spectral hole" recording properties for applications including high-bandwidth optical signal processing where light and our solids replace the high-bandwidth portion of the electronics; quantum cryptography and information science including the goal of storage and recall of single photons; and medical imaging technology for the 700-900 nm therapeutic window. Ease of optically manipulating rare-earth ions in solids enables capturing complex spectral information in 105 to 108 frequency bins. Combining spatial holography and spectral hole burning provides a capability for processing high-bandwidth RF and optical signals with sub-MHz spectral resolution and bandwidths of tens to hundreds of GHz for applications including range-Doppler radar and high bandwidth RF spectral analysis. Simply stated, one can think of these crystals as holographic recording media capable of distinguishing up to 108 different colors. Ultra-narrow spectral holes also serve as a vibration-insensitive sub-kHz frequency reference for laser frequency stabilization to a part in 1013 over tens of milliseconds. The unusual properties and applications of spectral hole burning of rare earth ions in optical materials are reviewed. Experimental results on the promising Tm3+:LiNbO3 material system are presented and discussed for medical imaging applications. Finally, a new application of these materials as dynamic optical filters for laser noise suppression is discussed along with experimental demonstrations and theoretical modeling of the process.

  18. Diagnostic imaging, a 'parallel' discipline. Can current technology provide a reliable digital diagnostic radiology department

    International Nuclear Information System (INIS)

    Moore, C.J.; Eddleston, B.

    1985-01-01

    Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted the authors argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. (author)

  19. Analysis of the development of missile-borne IR imaging detecting technologies

    Science.gov (United States)

    Fan, Jinxiang; Wang, Feng

    2017-10-01

    Today's infrared imaging guiding missiles are facing many challenges. With the development of targets' stealth, new-style IR countermeasures and penetrating technologies as well as the complexity of the operational environments, infrared imaging guiding missiles must meet the higher requirements of efficient target detection, capability of anti-interference and anti-jamming and the operational adaptability in complex, dynamic operating environments. Missileborne infrared imaging detecting systems are constrained by practical considerations like cost, size, weight and power (SWaP), and lifecycle requirements. Future-generation infrared imaging guiding missiles need to be resilient to changing operating environments and capable of doing more with fewer resources. Advanced IR imaging detecting and information exploring technologies are the key technologies that affect the future direction of IR imaging guidance missiles. Infrared imaging detecting and information exploring technologies research will support the development of more robust and efficient missile-borne infrared imaging detecting systems. Novelty IR imaging technologies, such as Infrared adaptive spectral imaging, are the key to effectively detect, recognize and track target under the complicated operating and countermeasures environments. Innovative information exploring techniques for the information of target, background and countermeasures provided by the detection system is the base for missile to recognize target and counter interference, jamming and countermeasure. Modular hardware and software development is the enabler for implementing multi-purpose, multi-function solutions. Uncooled IRFPA detectors and High-operating temperature IRFPA detectors as well as commercial-off-the-shelf (COTS) technology will support the implementing of low-cost infrared imaging guiding missiles. In this paper, the current status and features of missile-borne IR imaging detecting technologies are summarized. The key

  20. Gastroesophageal reflux disease. Scintigraphic, endoscopic and histologic considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kault, B.; Halvorsen, T.; Petersen, H.; Grette, K.; Myrvold, H.E.

    1986-01-01

    Radionucleotide scintigraphy and esophagoscopy with biopsy were carried out in 101 patients with symptoms strongly suggestive of gastroesophageal reflux (GER) disease. GER was visualized by scintigraphy in 86.1% of the patients. Endoscopic and histologic esophagitis were found in 68.1% and 58.4% of the patients, respectively, whereas both examinations taken together showed evidence of esophagitis in 82%. Histologic evidence of esophagitis was found in nearly all patients with severe endoscopic changes, and in 43.7% of the patients with no endoscopic abnormality. Scintigraphic reflux was demonstrated more frequently in the patients with severe endoscopic esophagitis (97.5%) than in those with no or only mild endoscopic changes (78.6%). Scintigraphic reflux was found in 91.5% and 78.5% of the patients with and without histologic evidence of esophagitis. 15 of the 18 patients (83.3%) without endoscopic and histologic abnormalities in the esophagus had scintigraphic evidence of reflux. The present study strongly supports the clinical significance of scintigraphy in GER disease and confirms that esophageal biopsy specimens increase the sensitivity of endoscopic evaluation. 31 refs.