WorldWideScience

Sample records for electrophoresis pattern ph

  1. Two-dimensional gel electrophoresis pattern (pH 6-11) and identification of water-soluble barley seed and malt proteins by mass spectrometry

    DEFF Research Database (Denmark)

    Bak-Jensen, K.S.; Laugesen, S.; Roepstorff, P.

    2004-01-01

    A protocol was established for two-dimensional gel electrophoresis (2-DE) of barley seed and malt proteins in the pH range of 6-11. Proteins extracted from flour in a low-salt buffer were focused after cup-loading onto IPG strips. Successful separation in the second dimension was achieved using...... gradient gels in a horizontal SDS-PAGE system. Silver staining of gels visualized around 380 (seed) and 500 (malt) spots. Thirty-seven different proteins from seeds were identified in 60 spots, among these 46 were visualized also in the malt 2-D pattern. Proteins were identified by peptide mass...... in defence against pathogens (21 spots), 4 in storage, folding, and synthesis of proteins, and in nitrogen metabolism (5 spots), 6 in carbohydrate metabolism (11 spots), and 4 in stress and detoxification (9 spots). Six proteins (7 spots) were not grouped in these categories, and 3 were not ascribed...

  2. Correlation of acidic and basic carrier ampholyte and immobilized pH gradient two-dimensional gel electrophoresis patterns based on mass spectrometric protein identification

    DEFF Research Database (Denmark)

    Nawrocki, A; Larsen, Martin Røssel; Podtelejnikov, A V

    1998-01-01

    Separation of proteins on either carrier ampholyte-based or immobilized pH gradient-based two-dimensional (2-D) gels gives rise to electrophoretic patterns that are difficult to compare visually. In this paper we have used matrix-assisted laser desorption/ionization mass spectrometry (MALDI......-MS) to determine the identities of 335 protein spots in these two 2-D gel systems, including a substantial number of basic proteins which had never been identified before. Proteins that were identified in both gel systems allowed us to cross-reference the gel patterns. Vector analysis of these cross...

  3. Electrophoresis test prevalence, requesting patterns, yield and ...

    African Journals Online (AJOL)

    Most of the appropriate SPE test requests were from clinical haematology, renal ... implementation of principles of demand management and the ... electrophoresis (IFE)) in a South African (SA) pathology laboratory setting are limited. Objectives. ... (NHLS) hospital information system database from 1 July 2010 to. 30 June ...

  4. Understanding Electrophoresis through the Investigation of Size, Shape, and Charge of pH Indicators

    Science.gov (United States)

    Brenner, Ryan K.; Hess, Kenneth R.; Morford, Jennifer L.

    2015-01-01

    A laboratory experiment was designed for upper-level students in a Chemical Analysis course to illustrate the theoretical and practical applications of 0.8% agarose gel electrophoresis and to reinforce an understanding of weak acids/bases using easy-to-visualize pH indicators. The careful choice of indicators included acid and base types with…

  5. Canine serum protein patterns using high-resolution electrophoresis (HRE).

    Science.gov (United States)

    Abate, O; Zanatta, R; Malisano, T; Dotta, U

    2000-03-01

    Serum protein values were determined in 26 healthy dogs using agarose gel electrophoresis (SPE), splitting the electrophoretic separation into six regions: albumin, alpha(1), alpha(2), beta(1), beta(2)and gamma globulins. High-resolution electrophoresis (HRE) was used to separate single proteins. Serum proteins from dogs (26 healthy and 20 affected by various diseases) were then characterized by electrophoretic immunofixation (IFE) and Sudan black staining on HRE film. Haemoglobin and normal canine plasma and serum were used to identify haptoglobin and fibrinogen, respectively. In the standard pattern, determined by HRE, the following proteins were identified: albumin, alpha(1)-lipoprotein (alpha(1)-region), haptoglobin and alpha(2)-macroglobulin (alpha(2)-region), beta -lipoprotein and C3 (beta(1)-region), transferrin and IgM (beta(2)-region), IgG (mostly in gamma -region and partly in beta(2)-region). The HRE pattern shown by healthy dogs could be compared with those of dogs affected by various diseases to obtain clinical information. Copyright 2000 Harcourt Publishers Ltd.

  6. In situ photo-immobilised pH gradient isoelectric focusing and zone electrophoresis integrated two-dimensional microfluidic chip electrophoresis for protein separation

    International Nuclear Information System (INIS)

    Lin, Fengmin; Yu, Shiyong; Gu, Le; Zhu, Xuetao; Wang, Jianshe; Zhu, Han; Lu, Yi; Wang, Yihua; Deng, Yulin; Geng, Lina

    2015-01-01

    A method is introduced for open-column photo-induced site-selective immobilization of pH gradients in a layer of PEG-methacrylate in a multi-dimensional microfluidic chip for use in electrophoresis. It has several attractive features: (a) mixtures of fluorescently labelled proteins carbonic anhydrase, catalase and myoglobin in their native state can be separated by pH-gradient isoelectric focusing (IEF) and zone electrophoresis (CZE) using integrated 2D chip electrophoresis; (b) compared to strip packing or monolithic photo-immobilization, it overcomes the shortcomings of free carrier ampholyte-based 2D chip electrophoresis in an easy way; (c) larger amount of sample can be loaded into the open column-mode electrophoresis (d) immobilized pH gradients can be re-used and the chip can be recycled; (e) a multilayer 3D pH gradient is established by a layer-by-layer assembly technique to further increase the separation capacity. In our perception, this strategy has a large potential in microfluidic chip-based separation schemes because of its simplicity, separation power, re-usability, and separation capacity. (author)

  7. Two dimensional gel electrophoresis using narrow pH 3-5.6 immobilised pH gradient strips identifies potential novel disease biomarkers in plasma or serum

    OpenAIRE

    sprotocols

    2015-01-01

    Authors: Bevin Gangadharan & Nicole Zitzmann ### Abstract Two-dimensional gel electrophoresis (2-DE) is a protein separation technique often used to separate plasma or serum proteins in an attempt to identify novel biomarkers. This protocol describes how to run 2-DE gels using narrow pH 3-5.6 immobilised pH gradient strips to separate 2 mg of serum proteins. pH 3-6 ampholytes are used to enhance the solubility of proteins in this pH range before the serum proteins are separated in the...

  8. Mapping and identification of interferon gamma-regulated HeLa cell proteins separated by immobilized pH gradient two-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Shaw, A.; Larsen, M.; Roepstorff, P.

    1999-01-01

    magnitude of IFN-gamma responsive genes has been reported previously. Our goal is to identify and map IFN-gamma-regulated HeLa cell proteins to the two-dimensional polyacrylamide gel electrophoresis with the immobilized pH gradient (IPG) two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) system...

  9. HIV and serum protein electrophoresis patterns in KwaZulu-Natal: a ...

    African Journals Online (AJOL)

    Objective. To describe the effect of HIV serostatus on serum proteins, serum protein electrophoresis (SPEP) patterns and monoclonal bands. Setting. Inkosi Albert Luthuli Central Hospital, Durban. Design. Retrospective, anonymous analysis of routine laboratory results. Results. Monoclonal bands were not increased in ...

  10. Multivariate data analysis of two-dimensional gel electrophoresis protein patterns from few samples

    DEFF Research Database (Denmark)

    Jensen, Kristina Nedenskov; Jessen, Flemming; Jørgensen, Bo

    2008-01-01

    One application of 2D gel electrophoresis is to reveal differences in protein pattern between two or more groups of individuals, attributable to their group membership. Multivariate data analytical methods are useful in pinpointing the spots relevant for discrimination by focusing not only...... on single spot differences, but on the covariance structure between proteins. However, their outcome is dependent on data scaling, and they may fail in producing valid multivariate models due to the much higher number of "irrelevant" spots present in the gels. The case where only few gels are available...... and where the aim is to find as many as possible of the group-dependent proteins seems particularly difficult to handle. The present paper investigates such a case regarding the effect of scaling and of prefiltering by univariate nonparametric statistics on the selection of spots. Besides, a modified...

  11. [Genotypic variability and persistence of Legionella pulsed-field gel electrophoresis patterns in 16 cooling towers in Shanghai, China].

    Science.gov (United States)

    Chen, Ming-liang; Wang, Gang-yi; Chen, Min; Zhou, Hai-jian; Shao, Zhu-jun; Zhang, Xi; Wu, Fan

    2010-07-01

    To investigate the genotypic characteristics and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns in 16 air-conditioner cooling towers in six different public sites of Shanghai. From May to October, continuous sampling was operated once per month in 2007. Legionella strains isolated from the 16 cooling towers were confirmed by serological and latex agglutination. PFGE was applied for the fingerprinting of the isolates, while the cluster results of PFGE were analyzed by BioNumerics software. 131 strains of Legionella were isolated, including L. pneumophila, L. bozemanae, L. micdadei and L. anisa. 52 distinguishable PFGE patterns were differentiated among the 16 cooling towers, with 37 patterns were owned by just one cooling tower, which was not shared with other cooling towers, while 15 patterns were shared by more than 2 cooling towers. All the cooling towers had ≥ 2 PFGE patterns, while in 13 cooling towers the same PFGE patterns were recovered during the six months. From June to October of 2007, 18 strains of Legionella belonging to the PFGE pattern of LPAs.SH0078 were isolated continuously from 6 cooling towers. This study demonstrated great genotypic diversity and complexity of Legionella in cooling towers. Persistence of the PFGE patterns was observed in 81.25% of the cooling towers. The PFGE pattern of LPAs. SH0078 was distributed widely, suggesting it might be the dominate strain in Shanghai.

  12. Protein Alterations in Infiltrating Ductal Carcinomas of the Breast as Detected by Nonequilibrium pH Gradient Electrophoresis and Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Maria Kabbage

    2008-01-01

    Full Text Available Improvement of breast-cancer detection through the identification of potential cancer biomarkers is considered as a promising strategy for effective assessment of the disease. The current study has used nonequilibrium pH gradient electrophoresis with subsequent analysis by mass spectrometry to identify protein alterations in invasive ductal carcinomas of the breast from Tunisian women. We have identified multiple protein alterations in tumor tissues that were picked, processed, and unambiguously assigned identities by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF. The proteins identified span a wide range of functions and are believed to have potential clinical applications as cancer biomarkers. They include glycolytic enzymes, molecular chaperones, cytoskeletal-related proteins, antioxydant enzymes, and immunologic related proteins. Among these proteins, enolase 1, phosphoglycerate kinase 1, deoxyhemoglobin, Mn-superoxyde dismutase, α-B-crystallin, HSP27, Raf kinase inhibitor protein, heterogeneous nuclear ribonucleoprotein A2/B1, cofilin 1, and peptidylprolyl isomerase A were overexpressed in tumors compared with normal tissues. In contrast, the IGHG1 protein, the complement C3 component C3c, which are two newly identified protein markers, were downregulated in IDCA tissues.

  13. Separation selectivity patterns of fully charged achiral compounds in capillary electrophoresis with a neutral cyclodextrin.

    Science.gov (United States)

    Soonthorntantikul, Wasura; Srisa-art, Monpichar; Leepipatpiboon, Natchanun; Nhujak, Thumnoon

    2013-01-01

    Based on the separation selectivity equation, related to the dimensionless parameters for fully charged achiral analytes using a neutral CD, the separation selectivity can be classified into seven patterns. With respect to CZE without CD, the presence of CD in the buffer may improve, or reduce, the separation selectivity with this effect being accompanied by the same or reversed electrophoretic mobility order for charged analytes. This can depend on the separation selectivity of the two analytes in free solution, the binding selectivity, the separation selectivity of analyte-CD complexes and the ratio of electrophoretic mobility of the analytes in free, and complexed forms. Using positional isomers of benzoic acids and phenoxy acids as test analytes and α-CD as a selector, the observed separation selectivity shapes were found to be in excellent agreement with the predicted separation selectivities. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. pH and its frequency distribution patterns of Acid Precipitation in Japan

    International Nuclear Information System (INIS)

    Kitamura, Moritsugu; Katou, Takunori; Sekiguchi, Kyoichi

    1991-01-01

    The pH data was collected at the 29 stations in Phase-I study of Acid Precipitation Survey over Japan by Japan Environment Agency in terms of frequency distribution patterns. This study was undertaken from April 1984 to March 1988, which was the first survey of acid precipitation over Japan with identical sampling procedures and subsequent chemical analyses. While the annual mean pH at each station ranged from 4.4 to 5.5, the monthly mean varied more widely, from 4.0 to 7.1. Its frequency distribution pattern was obtained for each station, and further grouped into four classes: class I; a mode at the rank of pH 4.5∼4.9, class II; bimodes above and below this pH region, class III; a mode at a higher pH region, class IV; a mode at a lower pH region. The bimodal pattern was suggestive of precipitation with and without incorporation of significant amounts of basic aerosol of anthropogenic origin during descent of rain droplet. The patterns of the stations were also classified on a basis of summer-winter difference into another four classes. Winter pH values were appreciably lower than summer pHs in western parts of Japan and on Japan Sea coast, we attribute the winter pH to probable contribution of acidic pollutants transported by strong winter monsoon from Eurasian Continent. At most stations in northern and eastern Japan, the pH was higher in winter months reflecting more incorporation of basic materials, e.g., NH 4 + and Ca 2+ . (author)

  15. Comparison of protein patterns after two-dimensional gel electrophoresis from leaves of in vitro cultures and seedlings of Rubus chamaemorus L.

    Directory of Open Access Journals (Sweden)

    Barbara Thiem

    2014-01-01

    Full Text Available Proteins from leaves of Rubus chamaemorus propagated in vitro were subjected to miniaturized 2-D electrophoresis. The 2-DE patterns of proteins showed qualitative differences between plants propagated in vitro and control seedlings. More proteins of a high molecular weight were observed in leaves of plants from in vitro culture. A two-dimensional map of proteins from leaves provides detailed data concerning both polymorphism and protein patterns of this species. This makes it possible to start constructing a protein map of R. chamaemorus. The reasons for qualitative differences are discussed.

  16. Exploration of beer proteome using OFFGEL prefractionation in combination with two-dimensional gel electrophoresis with narrow pH range gradients.

    Science.gov (United States)

    Konečná, Hana; Müller, Lukáš; Dosoudilová, Hana; Potěšil, David; Buršíková, Jana; Sedo, Ondrej; Márová, Ivana; Zdráhal, Zbyněk

    2012-03-14

    Two-dimensional gel electrophoresis in combination with mass spectrometry has already been applied successfully to study beer proteome. Due to the abundance of protein Z in beer samples, prefractionation techniques might help to improve beer proteome coverage. Proteins from four lager beers of different origins were separated by two-dimensional electrophoresis (2-DE) followed by tandem mass spectrometric analysis. Initially 52 proteins mostly from Hordeum vulgare (22 proteins) and Saccharomyces species (25 proteins) were identified. Preparative isoelectric focusing by OFFGEL Fractionator was applied prior to 2-DE to improve its resolution power. As a result of this combined approach, a total of 70 beer proteins from Hordeum vulgare (30 proteins), from Saccharomyces species (31 proteins), and from other sources (9 proteins) were identified. Of these, 37 proteins have not been previously reported in beer samples.

  17. Electrophoresis technology

    Science.gov (United States)

    Snyder, R. S.

    1985-01-01

    A new high resolution apparatus designed for space was built as a laboratory prototype. Using a moving wall with a low zeta potential coating, the major sources of flow distortion for an electrophoretic sample stream are removed. Highly resolved fractions, however, will only be produced in space because of the sensitivity of this chamber to buoyancy-induced convection in the laboratory. The second and third flights of the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system carried samples developed at MSFC intended to evaluate the broad capabilities of free flow electrophoresis in a reduced gravity environment. Biological model materials, hemoglobin and polystyrene latex microspheres, were selected because of their past use as electrophoresis standards and as visible markers for fluid flow due to electroosmosis, spacecraft acceleration or other factors. The dependence of the separation resolution on the properties of the sample and its suspension solution was assessed.

  18. Lectin affinity electrophoresis.

    Science.gov (United States)

    Kobayashi, Yuka

    2014-01-01

    An interaction or a binding event typically changes the electrophoretic properties of a molecule. Affinity electrophoresis methods detect changes in the electrophoretic pattern of molecules (mainly macromolecules) that occur as a result of biospecific interactions or complex formation. Lectin affinity electrophoresis is a very effective method for the detection and analysis of trace amounts of glycobiological substances. It is particularly useful for isolating and separating the glycoisomers of target molecules. Here, we describe a sensitive technique for the detection of glycoproteins separated by agarose gel-lectin affinity electrophoresis that uses antibody-affinity blotting. The technique is tested using α-fetoprotein with lectin (Lens culinaris agglutinin and Phaseolus vulgaris agglutinin)-agarose gels.

  19. Using Gel Electrophoresis To Illustrate Protein Diversity and Isoelectric Point.

    Science.gov (United States)

    Browning, Mark; Vanable, Joseph

    2002-01-01

    Demonstrates the differences in protein structures by focusing on isoelectric point with an experiment that is observable under certain pH levels in gel electrophoresis. Explains the electrophoresis procedure and reports results of the experiments. (YDS)

  20. A Comparison of Non-Typhoidal Salmonella from Humans and Food Animals Using Pulsed-Field Gel Electrophoresis and Antimicrobial Susceptibility Patterns

    Science.gov (United States)

    Sandt, Carol H.; Fedorka-Cray, Paula J.; Tewari, Deepanker; Ostroff, Stephen; Joyce, Kevin; M’ikanatha, Nkuchia M.

    2013-01-01

    Salmonellosis is one of the most important foodborne diseases affecting humans. To characterize the relationship between Salmonella causing human infections and their food animal reservoirs, we compared pulsed-field gel electrophoresis (PFGE) and antimicrobial susceptibility patterns of non-typhoidal Salmonella isolated from ill humans in Pennsylvania and from food animals before retail. Human clinical isolates were received from 2005 through 2011 during routine public health operations in Pennsylvania. Isolates from cattle, chickens, swine and turkeys were recovered during the same period from federally inspected slaughter and processing facilities in the northeastern United States. We found that subtyping Salmonella isolates by PFGE revealed differences in antimicrobial susceptibility patterns and, for human Salmonella, differences in sources and invasiveness that were not evident from serotyping alone. Sixteen of the 20 most common human Salmonella PFGE patterns were identified in Salmonella recovered from food animals. The most common human Salmonella PFGE pattern, Enteritidis pattern JEGX01.0004 (JEGX01.0003ARS), was associated with more cases of invasive salmonellosis than all other patterns. In food animals, this pattern was almost exclusively (99%) found in Salmonella recovered from chickens and was present in poultry meat in every year of the study. Enteritidis pattern JEGX01.0004 (JEGX01.0003ARS) was associated with susceptibility to all antimicrobial agents tested in 94.7% of human and 97.2% of food animal Salmonella isolates. In contrast, multidrug resistance (resistance to three or more classes of antimicrobial agents) was observed in five PFGE patterns. Typhimurium patterns JPXX01.0003 (JPXX01.0003 ARS) and JPXX01.0018 (JPXX01.0002 ARS), considered together, were associated with resistance to five or more classes of antimicrobial agents: ampicillin, chloramphenicol, streptomycin, sulfonamides and tetracycline (ACSSuT), in 92% of human and 80% of food

  1. Analysis of electrophoresis performance

    Science.gov (United States)

    Roberts, G. O.

    1984-01-01

    The SAMPLE computer code models electrophoresis separation in a wide range of conditions. Results are included for steady three dimensional continuous flow electrophoresis (CFE), time dependent gel and acetate film experiments in one or two dimensions and isoelectric focusing in one dimension. The code evolves N two dimensional radical concentration distributions in time, or distance down a CFE chamber. For each time or distance increment, there are six stages, successively obtaining the pH distribution, the corresponding degrees of ionization for each radical, the conductivity, the electric field and current distribution, and the flux components in each direction for each separate radical. The final stage is to update the radical concentrations. The model formulation for ion motion in an electric field ignores activity effects, and is valid only for low concentrations; for larger concentrations the conductivity is, therefore, also invalid.

  2. Detachable strong cation exchange monolith, integrated with capillary zone electrophoresis and coupled with pH gradient elution, produces improved sensitivity and numbers of peptide identifications during bottom-up analysis of complex proteomes.

    Science.gov (United States)

    Zhang, Zhenbin; Yan, Xiaojing; Sun, Liangliang; Zhu, Guijie; Dovichi, Norman J

    2015-04-21

    A detachable sulfonate-silica hybrid strong cation-exchange monolith was synthesized in a fused silica capillary, and used for solid phase extraction with online pH gradient elution during capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) proteomic analysis. Tryptic digests were prepared in 50 mM formic acid and loaded onto the strong cation-exchange monolith. Fractions were eluted using a series of buffers with lower concentration but higher pH values than the 50 mM formic acid background electrolyte. This combination of elution and background electrolytes results in both sample stacking and formation of a dynamic pH junction and allows use of relatively large elution buffer volumes while maintaining reasonable peak efficiency and resolution. A series of five pH bumps were applied to elute E. coli tryptic peptides from the monolith, followed by analysis using CZE coupled to an LTQ-Orbitrap Velos mass spectrometer; 799 protein groups and 3381 peptides were identified from 50 ng of the digest in a 2.5 h analysis, which approaches the identification rate for this organism that was obtained with an Orbitrap Fusion. We attribute the improved numbers of peptide and protein identifications to the efficient fractionation by the online pH gradient elution, which decreased the complexity of the sample in each elution step and improved the signal intensity of low abundance peptides. We also performed a comparative analysis using a nanoACQUITY UltraPerformance LCH system. Similar numbers of protein and peptide identifications were produced by the two methods. Protein identifications showed significant overlap between the two methods, whereas peptide identifications were complementary.

  3. The Study of Effect of Surimi Production Steps on Chemical Composition and Electrophoresis Pattern of Myofibrillar Proteins of Mechanically Deboned poultry meat (MDPM

    Directory of Open Access Journals (Sweden)

    Sh Haji BagherNaeeni

    2013-08-01

    Full Text Available Mechanically deboning poultry meat (MDPM is widely used due to its suitable technological properties as well as low lipids and saturated fatty acids contents. Besides, production processes applied during the surimi production can improve the technological properties of MDPM. That is to say, the production steps of surimi can change chemical composition and concentration of myofibrillar proteins and improve functional properties of MDPM. In this study, MDPM was prepared from the poultry meat. The production process consisted of 2 washing steps with sodium bicarbonate solution followed by another washing step with 4°C water. Afterwards, chemical properties of MDPM and surimi (moisture content, protein, lipid, and ash content as well as electrophoresis pattern were evaluated. Result showed that surimi production steps could significantly decrease protein, lipid and ash contents; however, moisture content of MDPM increased significantly. The result of electrophoresis indicated a significant increase in heavy chain myosin with 200 KDa and actin with 45 KDa molecular weights. It was concluded that the production steps improved the chemical properties and increased the concentration of MDPM myofibrillar proteins.

  4. Misleading presentation of haemoglobin electrophoresis data | Adu ...

    African Journals Online (AJOL)

    Haemoglobinopathies are common in sub-Saharan Africa. As such haemoglobin electrophoresis are required to inform clinical decision making. However, haemoglobin electrophoresis is an assay that detects protein at either alkaline or acidic pH. Such assays do not interrogate gene sequences but rather the product of a ...

  5. Spatial patterns of soil pH and the factors that influence them in plantation forests of northern China

    Science.gov (United States)

    Hong, Songbai; Liu, Yongwen; Piao, Shilong

    2017-04-01

    Climate and anthropogenic activities such as afforestation and nitrogen deposition all impact soil pH. Understanding the spatial pattern of soil pH and the factors that influence it can provide basic information for generating appropriate strategies for soil resource management and protection, especially in light of increasing anthropogenic influences and climate change. In this study, we investigated the spatial and vertical pattern of soil pH and evaluated the influence of climate and nitrogen deposition using 1647 soil profiles 1 meter in depth from 549 plots in plantation forests of northern China. We found that soil pH decreased from the southwest to the northeast in the study region and had a similar spatial pattern before and after afforestation. Furthermore, our results show that climate and nitrogen deposition fundamentally influence the pattern of soil pH. Specifically, increasing precipitation significantly decreased soil pH (with a mean rate of 0.3 for every 100 mm rainfall, ppH (0.13 for every degree centigrade, ppH (ppH directly and indirectly through climate-plant-soil interactions. As the risks from both climate change and nitrogen deposition increase, there is an urgent need to further understanding of soil pH dynamics and to develop informed policies to protect soil resources.

  6. Usefulness of the DNA-fingerprinting pattern and the multilocus enzyme electrophoresis profile in the assessment of outbreaks of meningococcal disease

    DEFF Research Database (Denmark)

    Weis, N; Lind, I

    1996-01-01

    cases were identical to the outbreak strain. None of the local serogroup C carrier strains isolated during the outbreak of serogroup C disease were identical to the outbreak strain. Both DNA-fingerprinting and MEE improved the differentiation of meningococci when compared with phenotypic......The objective of the study was to assess whether genotypic characterization by means of DNA-fingerprinting pattern (DFP) and multilocus enzyme electrophoresis (MEE) profile as compared to phenotypic characterization would improve the differentiation of Neisseria meningitidis strains associated...... in each outbreak were designated the index strains. Among the remaining 55 outbreak strains 52 were either DFP-identical or DFP-indistinguishable when compared with the one relevant out of the 4 index strains. This was only the case for 17 of the 37 strains isolated from sporadic cases caused by the same...

  7. Differences in serum protein 2D gel electrophoresis patterns of Przewalski's (Mongolian wild horse) and thoroughbred horses.

    Science.gov (United States)

    Barsuren, Enkhbolor; Namkhai, Bandi; Kong, Hong Sik

    2015-04-01

    The objective of this study was to assess differences in serum protein expression profiles of Przewalski's (Mongolian wild horse) and thoroughbred horses using proteome analysis. The serum proteins were separated by two-dimensional electrophoresis (2-DE) and five different gene products were identified. Proteins represented by the five spots were identified by matrix-assisted laser desorption ionization-time-of-flight (MALDI-TOF) mass spectrometry (MS)/MS technology. The identities of all proteins were deduced based on their similarity to proteins in the human plasma protein database. Three proteins (a haptoglobin-2 alpha glycoprotein and two haptoglobin-2beta glycoproteins with different accession numbers) were downregulated in Przewalski's horse sera compared to thoroughbred horse sera. Moreover, two proteins (tetraspanin-18 and pM5) were upregulated in Przewalski's horses compared to thoroughbred horses. Haptoglobin-2 alpha and haptoglobin-2beta may serve as candidate molecules in future studies of inflammation, coagulation, immune modulation and pro-oxidant and antioxidant activity with consequential effects on the entire metabolism of the horse. © 2014 Japanese Society of Animal Science.

  8. Down-regulation of triose phosphate isomerase in Vineristine-resistant gastric cancer SGC7901 cell line identified by immobilized pH gradient two-dimensional gel electrophoresis and mierosequencing

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Objective:To exkplore new multidrug-resistance-related proteins in gastric SC7901 cells and clarify their mechanisms.Methods:Two-dimensional(2-D) polyacrylamide gel electrophoresis with immobilized pH gradients(IPG) was applied to compare the differential expression of multidrug-resistance-related proteins in gastric cancer SGC7901 cells and Vineristine-resistant SGC7901 cells (SGC7901/VCR) induced by vincristine sulfate.The 2-D gels were silver-stained.Then,preparative 2-D PAGE was performed.The differential proteins of PVDF membranes were cxcised and identified by N-terminal microsequencing.The mRNA expressions of differential proteins were detected in SGC 7901 cells and SGC7901/VCR cells by RT-PCR.Results:Approximatedly 680 protein sports were resolved on each 2-D gel by silver staining.Most protein spots showed no difference in composition,shape or density.25 proteins differed in abundance (6 higher in SGC7901/VCR cells;19 higher in 7901 cells);5 proteins were unique to one kind of cell or the othe(3 in SGC7901/VRC cells,2 in 7901 cells).One drug-resistance-related protein,which was down-regulated in SGC7901/VCR cells,was identified as trisephosphate isomerase(TPI),a glycolytic pathway enzyme.Conclusions:the results suggest that these differential proteins including TPI may be related to the Vincristine-resistant mechanism in human gastric cancer SGC7901/VCR cell line.

  9. Correlation of MFOLD-predicted DNA secondary structures with separation patterns obtained by capillary electrophoresis single-strand conformation polymorphism (CE-SSCP) analysis.

    Science.gov (United States)

    Glavac, Damjan; Potocnik, Uros; Podpecnik, Darja; Zizek, Teofil; Smerkolj, Sava; Ravnik-Glavac, Metka

    2002-04-01

    We have studied 57 different mutations within three beta-globin gene promoter fragments with sizes 52 bp, 77 bp, and 193 bp by fluorescent capillary electrophoresis CE-SSCP analysis. For each mutation and wild type, energetically most-favorable predicted secondary structures were calculated for sense and antisense strands using the MFOLD DNA-folding algorithm in order to investigate if any correlation exists between predicted DNA structures and actual CE migration time shifts. The overall CE-SSCP detection rate was 100% for all mutations in three studied DNA fragments. For shorter 52 bp and 77 bp DNA fragments we obtained a positive correlation between the migration time shifts and difference in free energy values of predicted secondary structures at all temperatures. For longer 193 bp beta-globin gene fragments with 46 mutations MFOLD predicted different secondary structures for 89% of mutated strands at 25 degrees C and 40 degrees C. However, the magnitude of the mobility shifts did not necessarily correlate with their secondary structures and free energy values except for the sense strand at 40 degrees C where this correlation was statistically significant (r = 0.312, p = 0.033). Results of this study provided more direct insight into the mechanism of CE-SSCP and showed that MFOLD prediction could be helpful in making decisions about the running temperatures and in prediction of CE-SSCP data patterns, especially for shorter (50-100 bp) DNA fragments. Copyright 2002 Wiley-Liss, Inc.

  10. Dermatoglyphic patterns and salivary pH in subjects with and without dental caries: A cross-sectional study.

    Science.gov (United States)

    Yamunadevi, Andamuthu; Dineshshankar, Janardhanam; Banu, Safeena; Fathima, Nilofar; Ganapathy; Yoithapprabhunath, Thukanayakanpalayam Ragunathan; Maheswaran, Thangadurai; Ilayaraja, Vadivel

    2015-01-01

    Dermatoglyphic patterns, which are regularly used in judicial and legal investigations, can be valuable in the diagnosis of many diseases associated with genetic disorders. Dental caries although of infectious origin, may have a genetic predisposition. Hence, we evaluated the correlation between dental caries and dermatoglyphic patterns among subjects with and without dental caries and evaluated its association with environmental factors such as salivary pH. Totally, 76 female students within the age group of 18-23 years were clinically examined, and their decayed, missing, filled teeth (DMFT) score and oral hygiene index-simplified were recorded. Based on their DMFT score, they were divided into following three groups; group I (n = 16, DMFT score = 0), group II (n = 30, DMFT score salivary pH were recorded and analyzed using descriptive statistics. Dermatoglyphic pattern distribution in caries-free group showed more ulnar loops than high caries group (group III) while high caries group showed more whorl patterns. Presence of whorl with double loop, whorl within a loop was associated with high DMFT score. The total finger ridge count was lower in caries group. The mean salivary pH was higher in caries-free group than high caries group. Thus, we conclude that dermatoglyphic patterns may be potential diagnostic tool for detecting patients prone to develop dental caries.

  11. Success and failure with phthalate buffers in capillary zone electrophoresis.

    Science.gov (United States)

    Bocek, P; Gebauer, P; Beckers, J L

    2001-04-01

    Phthalate buffers are currently used in capillary electrophoresis as robust electrolyte systems for indirect detection. This contribution demonstrates that these buffers show regularly not only successful regions of mobilities of analytes (sample window) but also regions of failure where the migration of analytes is strongly deteriorated due to the presence of a system zone. System zones in phthalate buffers may be easily detected by UV detection and manifest themselves as peaks or dips. Peak shape diagrams are advantageously used for the prediction of the migration behavior of system zones in phthalate background electrolyte (BGE) systems at various pH. It is shown that the mobility of the system zone varies strongly with pH, is practically zero at pH values below 4 and above 7, and shows a maximum at pH 5. Thus, the system peak may coincide either with the peaks of various analytes or with the electroosmotic flow (EOF) peak. Experiments are given showing the effects of such coincidences as, e.g., zigzag detection patterns, double EOF peaks, and/or unusually broad peaks/dips. The message of this contribution is to show how to understand the electrophoretic properties of phthalate BGEs that, regardless of possible failure regions, may be successfully used in the analytical practice of capillary zone electrophoresis (CZE).

  12. Susceptibility of Ph-positive all to TKI therapy associated with Bcr-Abl rearrangement patterns: a retrospective analysis.

    Directory of Open Access Journals (Sweden)

    Yu Jing

    Full Text Available BACKGROUND: Tyrosine kinase inhibitors (TKIs have demonstrated success in the treatment of acute lymphoblastic leukemia (ALL in patients that express BCR-ABL rearrangements (Philadelphia chromosome [Ph]. The current study aimed to assess the efficacy of TKIs and prognostic factors in the treatment of adults with Ph+-ALL. METHODS: In this multicenter retrospective study, the relationship between Ph+-ALL and treatment outcomes among Chinese patients receiving TKI-containing induction/consolidation chemotherapy was examined. A total of 86 Ph+-ALL patients were included and followed for 3.85 (0.43-9.30 years. Overall survival (OS and event-free survival (EFS were analyzed. RESULTS: A total of 86 Ph+-ALL patients (40 females and 46 males; median age: 34.0 years were enrolled, including those with BCR/ABL transcripts 190 (n = 52, 210 (n = 25, and 230 (n = 2; BCR/ABL isoform determination was not available for 7 patients. Mortality was influenced by variable BCR/ABL transcripts and TKI administration, and BCR/ABL transcripts, hematopoietic stem cell transplantation (HSCT, and TKI administration were associated with the occurrence of events. The OS rate in the TKI administration group during steady state was significantly higher compared with those patients who did not receive TKI administration (P = 0.008, the EFS rate in the TKI administration group during steady state was significantly higher compared with those patients who did not receive TKIs (P = 0.012, and also higher than those with TKI salvage administration (P = 0.004. BCR/ABL transcripts 210 showed preferable OS and EFS compared with BCR/ABL transcripts 190 and 230 (P<0.05 for each. CONCLUSIONS: The susceptibility of Ph+-ALL to TKI associated with the patterns of BCR-ABL rearrangement is demonstrated for the first time, thus adding another risk-stratifying molecular prognostic tool for the management of patients with Ph+-ALL.

  13. Predicting umbilical artery pH during labour: Development and validation of a nomogram using fetal heart rate patterns.

    Science.gov (United States)

    Ramanah, Rajeev; Omar, Sikiyah; Guillien, Alicia; Pugin, Aurore; Martin, Alain; Riethmuller, Didier; Mottet, Nicolas

    2018-06-01

    Nomograms are statistical models that combine variables to obtain the most accurate and reliable prediction for a particular risk. Fetal heart rate (FHR) interpretation alone has been found to be poorly predictive for fetal acidosis while other clinical risk factors exist. The aim of this study was to create and validate a nomogram based on FHR patterns and relevant clinical parameters to provide a non-invasive individualized prediction of umbilical artery pH during labour. A retrospective observational study was conducted on 4071 patients in labour presenting singleton pregnancies at >34 gestational weeks and delivering vaginally. Clinical characteristics, FHR patterns and umbilical cord gas of 1913 patients were used to construct a nomogram predicting an umbilical artery (Ua) pH <7.18 (10th centile of the study population) after an univariate and multivariate stepwise logistic regression analysis. External validation was obtained from an independent cohort of 2158 patients. Area under the receiver operating characteristics (ROC) curve, sensitivity, specificity, positive and negative predictive values of the nomogram were determined. Upon multivariate analysis, parity (p < 0.01), induction of labour (p = 0.01), a prior uterine scar (p = 0.02), maternal fever (p = 0.02) and the type of FHR (p < 0.01) were significantly associated with an Ua pH <7.18 (p < 0.05). Apgar score at 1, 5 and 10 min were significantly lower in the group with an Ua pH <7.18 (p < 0.01). The nomogram constructed had a Concordance Index of 0.75 (area under the curve) with a sensitivity of 57%, a specificity of 91%, a negative predictive value of 5% and a positive predictive value of 99%. Calibration found no difference between the predicted probabilities and the observed rate of Ua pH <7.18 (p = 0.63). The validation set had a Concordance Index of 0.72 and calibration with a p < 0.77. We successfully developed and validated a nomogram to predict Ua pH by

  14. Biofilm three-dimensional architecture influences in situ pH distribution pattern on the human enamel surface.

    Science.gov (United States)

    Xiao, Jin; Hara, Anderson T; Kim, Dongyeop; Zero, Domenick T; Koo, Hyun; Hwang, Geelsu

    2017-06-01

    To investigate how the biofilm three-dimensional (3D) architecture influences in situ pH distribution patterns on the enamel surface. Biofilms were formed on human tooth enamel in the presence of 1% sucrose or 0.5% glucose plus 0.5% fructose. At specific time points, biofilms were exposed to a neutral pH buffer to mimic the buffering of saliva and subsequently pulsed with 1% glucose to induce re-acidification. Simultaneous 3D pH mapping and architecture of intact biofilms was performed using two-photon confocal microscopy. The enamel surface and mineral content characteristics were examined successively via optical profilometry and microradiography analyses. Sucrose-mediated biofilm formation created spatial heterogeneities manifested by complex networks of bacterial clusters (microcolonies). Acidic regions (pHinterior of microcolonies, which impedes rapid neutralization (taking more than 120 min for neutralization). Glucose exposure rapidly re-created the acidic niches, indicating formation of diffusion barriers associated with microcolonies structure. Enamel demineralization (white spots), rougher surface, deeper lesion and more mineral loss appeared to be associated with the localization of these bacterial clusters at the biofilm-enamel interface. Similar 3D architecture was observed in plaque-biofilms formed in vivo in the presence of sucrose. The formation of complex 3D architectures creates spatially heterogeneous acidic microenvironments in close proximity of enamel surface, which might correlate with the localized pattern of the onset of carious lesions (white spot like) on teeth.

  15. Biomedical Science Ph.D. Career Interest Patterns by Race/Ethnicity and Gender.

    Directory of Open Access Journals (Sweden)

    Kenneth D Gibbs

    Full Text Available Increasing biomedical workforce diversity remains a persistent challenge. Recent reports have shown that biomedical sciences (BMS graduate students become less interested in faculty careers as training progresses; however, it is unclear whether or how the career preferences of women and underrepresented minority (URM scientists change in manners distinct from their better-represented peers. We report results from a survey of 1500 recent American BMS Ph.D. graduates (including 276 URMs that examined career preferences over the course of their graduate training experiences. On average, scientists from all social backgrounds showed significantly decreased interest in faculty careers at research universities, and significantly increased interest in non-research careers at Ph.D. completion relative to entry. However, group differences emerged in overall levels of interest (at Ph.D. entry and completion, and the magnitude of change in interest in these careers. Multiple logistic regression showed that when controlling for career pathway interest at Ph.D. entry, first-author publication rate, faculty support, research self-efficacy, and graduate training experiences, differences in career pathway interest between social identity groups persisted. All groups were less likely than men from well-represented (WR racial/ethnic backgrounds to report high interest in faculty careers at research-intensive universities (URM men: OR 0.60, 95% CI: 0.36-0.98, p = 0.04; WR women: OR: 0.64, 95% CI: 0.47-0.89, p = 0.008; URM women: OR: 0.46, 95% CI: 0.30-0.71, p<0.001, and URM women were more likely than all other groups to report high interest in non-research careers (OR: 1.93, 95% CI: 1.28-2.90, p = 0.002. The persistence of disparities in the career interests of Ph.D. recipients suggests that a supply-side (or "pipeline" framing of biomedical workforce diversity challenges may limit the effectiveness of efforts to attract and retain the best and most

  16. The Cutting Edge of Affinity Electrophoresis Technology

    Science.gov (United States)

    Kinoshita, Eiji; Kinoshita-Kikuta, Emiko; Koike, Tohru

    2015-01-01

    Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years. PMID:28248262

  17. The Cutting Edge of Affinity Electrophoresis Technology.

    Science.gov (United States)

    Kinoshita, Eiji; Kinoshita-Kikuta, Emiko; Koike, Tohru

    2015-03-18

    Affinity electrophoresis is an important technique that is widely used to separate and analyze biomolecules in the fields of biology and medicine. Both quantitative and qualitative information can be gained through affinity electrophoresis. Affinity electrophoresis can be applied through a variety of strategies, such as mobility shift electrophoresis, charge shift electrophoresis or capillary affinity electrophoresis. These strategies are based on changes in the electrophoretic patterns of biological macromolecules that result from interactions or complex-formation processes that induce changes in the size or total charge of the molecules. Nucleic acid fragments can be characterized through their affinity to other molecules, for example transcriptional factor proteins. Hydrophobic membrane proteins can be identified by means of a shift in the mobility induced by a charged detergent. The various strategies have also been used in the estimation of association/disassociation constants. Some of these strategies have similarities to affinity chromatography, in that they use a probe or ligand immobilized on a supported matrix for electrophoresis. Such methods have recently contributed to profiling of major posttranslational modifications of proteins, such as glycosylation or phosphorylation. Here, we describe advances in analytical techniques involving affinity electrophoresis that have appeared during the last five years.

  18. Potential of capillary electrophoresis for the profiling of propolis

    NARCIS (Netherlands)

    Hilhorst, M.J; Somsen, G.W; de Jong, G.J.

    1998-01-01

    The usefulness of capillary electrophoresis (CE) with diode array detection for the profiling of Propolis, a hive product, is investigated. Water extracts of Propolis were analyzed with both capillary zone electrophoresis (CZE) at pH 7.0 and 9.3, and micellar electrokinetic chromatography (MEKC)

  19. Electrophoresis forum '80

    International Nuclear Information System (INIS)

    Radola, B.J.

    1980-01-01

    In this volume the contributions of the electrophoresis meeting are presented in a short term form. The main topics are gel-electrophoresis, ultra thin film isoelectric focusing, one- and two-dimensional electrophoresis, electrophoretical separation techniques, electric focusing (for phorensic studies), substrate free and substrate electrophoresis. In the poster session of this meeting subjects such as (ultra) thin film isoelectric focusing, identification of radioactive proteins, labelling of cell surfaces, autoradiography and 3 H-labelled proteins. Separate abstracts were prepared for 4 papers in this report. (HK) [de

  20. Affinity in electrophoresis.

    Science.gov (United States)

    Heegaard, Niels H H

    2009-06-01

    The journal Electrophoresis has greatly influenced my approaches to biomolecular affinity studies. The methods that I have chosen as my main tools to study interacting biomolecules--native gel and later capillary zone electrophoresis--have been the topic of numerous articles in Electrophoresis. Below, the role of the journal in the development and dissemination of these techniques and applications reviewed. Many exhaustive reviews on affinity electrophoresis and affinity CE have been published in the last few years and are not in any way replaced by the present deliberations that are focused on papers published by the journal.

  1. Antero-posterior patterning of the vertebrate digestive tract: 40 years after Nicole Le Douarin's PhD thesis.

    Science.gov (United States)

    Grapin-Botton, Anne

    2005-01-01

    This review is dedicated to the work on chick digestive tract organogenesis that Nicole Le Douarin performed as a PhD student under the direction of Etienne Wolf. I discuss how she laid the grounds for future work by establishing fate maps at somitic stages, by describing morphogenetic movements between germ layers and by pointing to signaling events between endoderm and mesoderm. Her inspiring work was extended by others, in particular at the molecular level, leading to a better understanding of antero-posterior patterning in the digestive tract. Antero-posterior patterning of endoderm is initiated at gastrulation when future anterior and posterior endoderm ingress at different times and accordingly express different genes. Plasticity is however maintained at somite stages and even later, when organ primordia can be delineated. There is a cross-talk between endoderm and mesoderm and the two layers exchange instructive signals that induce specific antero-posterior identities as well as permissive signals required for organogenesis from previously patterned fields. Recent experiments suggest that several signaling molecules involved in neural tube antero-posterior patterning are also instrumental in the digestive tract including retinoic acid and FGF4.

  2. Disc electrophoresis and related techniques of polyacrylamide gel electrophoresis

    National Research Council Canada - National Science Library

    Maurer, H. R

    1971-01-01

    ..., enzymes, antingens and radioactively labelled materials, and detailed treatments of micro disc electrophoresis, preparative polyacrylamide gel electrophoresis and many other techniques for special problems...

  3. Study of total seed proteins pattern of sesame (sesamum indicum l.) landraces via sodium dodecyl sulfate polyacrylamide gel electrophoresis (sds-page)

    International Nuclear Information System (INIS)

    Akbar, F.; Shinwari, Z.K.

    2012-01-01

    The sesame (Sesamum indicum L.) germplasm, comprising of 105 accessions was characterized for total seed storage proteins using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The germplasm was collected from diverse agro-ecological regions of Pakistan. To our information, no studies have yet been carried out in Pakistan on the genetic evaluation of sesame genotypes based on total seed protein. Total seed proteins were electrophoretically separated on 12% polyacrylamide gels by standard protocols. A total of 20 polypeptide bands were observed, of which 14 (70%) were polymorphic and 6 (30%) were monomorphic, with molecular weight ranging from 13.5 to 100 kDa. Six bands i.e., 7, 11, 12, 15, 16 and 18 were common in all genotypes. Similarity coefficients varied fro m 0.50 to 1.00. The dendrogram based on dissimilarity matrix using unweighted pair group method with arithmetic averages (UPGMA) separated all sesame accessions into three main groups i.e., A, B, C, comprising 89, 14 and 2 genotypes, respectively. Overall a low to medium level of genetic variability was observed for SDS-PAGE (single dimension). As SDS-PAGE alone did not reveal high level of genetic variability, hence 2-D gel electrophoresis along with other advanced type DNA markers and more number of sesame accessions from all over the country are recommended for the future genetic evaluation. Our investigation will significantly support the classification, development, genetic evaluation and conservation of sesame germplasm in Pakistan. (author)

  4. Study of total seed proteins pattern of sesame (sesamum indicum l.) landraces via sodium dodecyl sulfate polyacrylamide gel electrophoresis (sds-page)

    Energy Technology Data Exchange (ETDEWEB)

    Akbar, F; Shinwari, Z K [Quaid-e-Azam University, Islamabad (Pakistan). Dept. of Biotechnology; Yousif, N; Masood, M S [Institute of Agri-Biotechnology and Genetic Resources, Islamabad (Pakistan)

    2012-11-15

    The sesame (Sesamum indicum L.) germplasm, comprising of 105 accessions was characterized for total seed storage proteins using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The germplasm was collected from diverse agro-ecological regions of Pakistan. To our information, no studies have yet been carried out in Pakistan on the genetic evaluation of sesame genotypes based on total seed protein. Total seed proteins were electrophoretically separated on 12% polyacrylamide gels by standard protocols. A total of 20 polypeptide bands were observed, of which 14 (70%) were polymorphic and 6 (30%) were monomorphic, with molecular weight ranging from 13.5 to 100 kDa. Six bands i.e., 7, 11, 12, 15, 16 and 18 were common in all genotypes. Similarity coefficients varied fro m 0.50 to 1.00. The dendrogram based on dissimilarity matrix using unweighted pair group method with arithmetic averages (UPGMA) separated all sesame accessions into three main groups i.e., A, B, C, comprising 89, 14 and 2 genotypes, respectively. Overall a low to medium level of genetic variability was observed for SDS-PAGE (single dimension). As SDS-PAGE alone did not reveal high level of genetic variability, hence 2-D gel electrophoresis along with other advanced type DNA markers and more number of sesame accessions from all over the country are recommended for the future genetic evaluation. Our investigation will significantly support the classification, development, genetic evaluation and conservation of sesame germplasm in Pakistan. (author)

  5. Protein electrophoresis - serum

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003540.htm Protein electrophoresis - serum To use the sharing features on ... JavaScript. This lab test measures the types of protein in the fluid (serum) part of a blood ...

  6. Urine protein electrophoresis test

    Science.gov (United States)

    Urine protein electrophoresis; UPEP; Multiple myeloma - UPEP; Waldenström macroglobulinemia - UPEP; Amyloidosis - UPEP ... special paper and apply an electric current. The proteins move and form visible bands. These reveal the ...

  7. Acidic digestion in a teleost: postprandial and circadian pattern of gastric pH, pepsin activity, and pepsinogen and proton pump mRNAs expression.

    Science.gov (United States)

    Yúfera, Manuel; Moyano, Francisco J; Astola, Antonio; Pousão-Ferreira, Pedro; Martínez-Rodríguez, Gonzalo

    2012-01-01

    Two different modes for regulation of stomach acid secretion have been described in vertebrates. Some species exhibit a continuous acid secretion maintaining a low gastric pH during fasting. Others, as some teleosts, maintain a neutral gastric pH during fasting while the hydrochloric acid is released only after the ingestion of a meal. Those different patterns seem to be closely related to specific feeding habits. However, our recent observations suggest that this acidification pattern could be modified by changes in daily feeding frequency and time schedule. The aim of this study was to advance in understanding the regulation mechanisms of stomach digestion and pattern of acid secretion in teleost fish. We have examined the postprandial pattern of gastric pH, pepsin activity, and mRNA expression for pepsinogen and proton pump in white seabream juveniles maintained under a light/dark 12/12 hours cycle and receiving only one morning meal. The pepsin activity was analyzed according to the standard protocol buffering at pH 2 and using the actual pH measured in the stomach. The results show how the enzyme precursor is permanently available while the hydrochloric acid, which activates the zymogen fraction, is secreted just after the ingestion of food. Results also reveal that analytical protocol at pH 2 notably overestimates true pepsin activity in fish stomach. The expression of the mRNA encoding pepsinogen and proton pump exhibited almost parallel patterns, with notable increases during the darkness period and sharp decreases just before the morning meal. These results indicate that white seabream uses the resting hours for recovering the mRNA stock that will be quickly used during the feeding process. Our data clearly shows that both daily illumination pattern and feeding time are involved at different level in the regulation of the secretion of digestive juices.

  8. Acidic digestion in a teleost: postprandial and circadian pattern of gastric pH, pepsin activity, and pepsinogen and proton pump mRNAs expression.

    Directory of Open Access Journals (Sweden)

    Manuel Yúfera

    Full Text Available Two different modes for regulation of stomach acid secretion have been described in vertebrates. Some species exhibit a continuous acid secretion maintaining a low gastric pH during fasting. Others, as some teleosts, maintain a neutral gastric pH during fasting while the hydrochloric acid is released only after the ingestion of a meal. Those different patterns seem to be closely related to specific feeding habits. However, our recent observations suggest that this acidification pattern could be modified by changes in daily feeding frequency and time schedule. The aim of this study was to advance in understanding the regulation mechanisms of stomach digestion and pattern of acid secretion in teleost fish. We have examined the postprandial pattern of gastric pH, pepsin activity, and mRNA expression for pepsinogen and proton pump in white seabream juveniles maintained under a light/dark 12/12 hours cycle and receiving only one morning meal. The pepsin activity was analyzed according to the standard protocol buffering at pH 2 and using the actual pH measured in the stomach. The results show how the enzyme precursor is permanently available while the hydrochloric acid, which activates the zymogen fraction, is secreted just after the ingestion of food. Results also reveal that analytical protocol at pH 2 notably overestimates true pepsin activity in fish stomach. The expression of the mRNA encoding pepsinogen and proton pump exhibited almost parallel patterns, with notable increases during the darkness period and sharp decreases just before the morning meal. These results indicate that white seabream uses the resting hours for recovering the mRNA stock that will be quickly used during the feeding process. Our data clearly shows that both daily illumination pattern and feeding time are involved at different level in the regulation of the secretion of digestive juices.

  9. SPATIAL AND TEMPORAL PATTERN OF SOIL pH AND Eh AND THEIR IMPACT ON SOLUTE IRON CONTENT IN A WETLAND (TRANSDANUBIA, HUNGARY

    Directory of Open Access Journals (Sweden)

    SZALAI ZOLTÁN

    2008-06-01

    Full Text Available Land mosaics have direct and indirect influence on chemical reaction and redox condition of soils. The present paper deals with the relationship between some environmental factors (such as soil andvegetation patterns, micro-relief, water regime, temperature and incident solar radiation and the pH, Eh of soils and solute iron in a headwater wetland in Transdanubia, Hungary. Measurements have been taken in four different patches and along their boundaries: sedge (Carex vulpina, Carex riparia, three patches and two species, horsetail (Equisetum arvense, common nettle (Urtica dioica. Thespatial pattern of the studied parameters are influenced by the water regime, micro-topography, climatic conditions and by direct and indirect effects of vegetation. The indirect effect can be the shading, which has influence on soil temperature and on the incident solar radiation (PAR. Root respiration and excretion of organic acids appear as direct effects.. There have been measured individual pH and Eh characteristic in the studied patches. Soil Eh, pH and solute iron have shown seasonal dynamics. Higher redox potentials (increasingly oxidative conditions and higher pH values were measured between late autumn and early spring. The increasing physiological activity of plants causes lower pH and Eh and it leads to higher spatial differences. Although temperature is an essential determining factor for Eh and pH, but our results suggest it rather has indirect effectsthrough plants on wetlands.

  10. Use of electrophoresis and immunoelectrophoresis in taxonomic and pollution studies

    Digital Repository Service at National Institute of Oceanography (India)

    Menezes, M.R.; Qasim, S.Z.

    Studies were conducted on the electrophoresis of blood serum and eye lens proteins of 5 fishes and immunoelectrophoresis of the soluble lens proteins of 10 fishes. The effects of a toxic pollutant (mercury) on the electrophoretic patterns...

  11. Identification of the EcoKI and EcoR1241 Type I Restriction-Modification Enzyme Subunits by Non-Equilibrium pH Gradient Two-Dimensional Gel Electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Nguyen, L. D.; Cajthamlová, Kamila; Nguyen, H. T.; Weiser, Jaroslav; Holubová, Inge; Weiserová, Marie

    2002-01-01

    Roč. 47, č. 6 (2002), s. 641-648 ISSN 0015-5632 R&D Projects: GA ČR GA301/00/1369; GA ČR GA204/00/1252 Institutional research plan: CEZ:AV0Z5020903 Keywords : ecoki * non-equilibrium ph * gradient Subject RIV: EE - Microbiology, Virology Impact factor: 0.979, year: 2002

  12. Influence of ignored and well-known zone distortions on the separation performance of proteins in capillary free zone electrophoresis with special reference to analysis in polyacrylamide-coated fused silica capillaries in various buffers. II. Experimental studies at acidic pH with on-line enrichment.

    Science.gov (United States)

    Mohabbati, Sheila; Hjertén, Stellan; Westerlund, Douglas

    2004-10-22

    The separation of acidic and basic model proteins was studied in capillary free zone electrophoresis in a polyacrylamide-coated, electroosmosis-free capillary at pH below their isoelectric points (pI) using various buffers at pH 2.7-4.8 with UV detection at 200 nm. The separation performance was significantly dependent on the coating quality, which may even differ within the same batch of capillaries. In addition, a washing step with 2 M HCl and the storage of the capillary in distilled water was essential for the performance. For high efficiency and resolution the choice of buffer constituents was extremely important which is discussed in quantitative terms in Part I. The most promising buffers were ammonium acetate and ammonium hydroxyacetate at pH 4 (ionic strengths: 0.12 and 0.15 M, respectively) with plate numbers up to 1,700,000 plates/m, corresponding to a zone width (2sigma) of only 1 mm in a capillary with 40 cm effective length, when the injected samples were dissolved in a 10-fold diluted background electrolyte (BGE), a zone even narrower than those obtained in polyacrylamide gel electrophoresis, the characteristic feature of which is remarkably thin zones. In the experiment giving this plate number, the calculated variance for longitudinal diffusion was larger than all the other calculated variances (those for the width of the starting zone, Joule heating, sedimentation and the curvature of the capillary). Interestingly, the effect of capillary curvature was significant. In addition, the sum of all other imaginable variances (corresponding to various types of slow on/off kinetics and hyper-sharp peaks) was in the most successful experiments only 28-50% of the variance for longitudinal diffusion. One hundred- to two hundred-fold dilution of the BGE improved the detection limits and provided high precision in both migration times and peak areas with ammonium hydroxyacetate and ammonium acetate as background electrolytes. However, that high dilution

  13. Seed Biology of Medicinal Plants (IX) : The Relationship of Corydalis Species Derived by Gel Electrophoresis

    OpenAIRE

    米田, 該典; 加賀, 順二; 那須, 正夫; KAISUKE, YONEDA; JUNJI, KAGA; MASAO, NASU; 大阪大学薬学部; 大阪大学薬学部; 大阪大学薬学部; Faculty of Pharmaceutical Sciences, Osaka University; Faculty of Pharmaceutical Sciences, Osaka University; Faculty of Pharmaceutical Sciences, Osaka University

    1987-01-01

    The saline soluble protein fraction of seeds of the Corydalis species (Papaveraceae) in Japan was examined by polyacrylamide gel electrophoresis and SDS-polyacrylamide gel electrophoresis. The esterase zymogram suggested that C. pallida, C. pallida var. tenuis, C. heterocarpa var. japonica and C. speciosa, having yellow flowers and no tuber, are closely related to each other. Electrophoresis and SDS-electrophoresis patterns also coincided with the result of the esterase zymogram. They also su...

  14. Practical capillary electrophoresis

    CERN Document Server

    Weinberger, Robert

    2000-01-01

    In the 1980s, capillary electrophoresis (CE) joined high-performance liquid chromatography (HPLC) as the most powerful separation technique available to analytical chemists and biochemists. Published research using CE grew from 48 papers in the year of commercial introduction (1988) to 1200 in 1997. While only a dozen major pharmaceutical and biotech companies have reduced CE to routine practice, the applications market is showing real or potential growth in key areas, particularly in the DNA marketplace for genomic mapping and forensic identification. For drug development involving small molecules (including chiral separations), one CE instrument can replace 10 liquid chromatographs in terms of speed of analysis. CE also uses aqueous rather than organic solvents and is thus environmentally friendlier than HPLC. The second edition of Practical Capillary Electrophoresis has been extensively reorganized and rewritten to reflect modern usage in the field, with an emphasis on commercially available apparatus and ...

  15. Dynamic patterns and ecological impacts of declining ocean pH in a high-resolution multi-year dataset.

    Science.gov (United States)

    Wootton, J Timothy; Pfister, Catherine A; Forester, James D

    2008-12-02

    Increasing global concentrations of atmospheric CO(2) are predicted to decrease ocean pH, with potentially severe impacts on marine food webs, but empirical data documenting ocean pH over time are limited. In a high-resolution dataset spanning 8 years, pH at a north-temperate coastal site declined with increasing atmospheric CO(2) levels and varied substantially in response to biological processes and physical conditions that fluctuate over multiple time scales. Applying a method to link environmental change to species dynamics via multispecies Markov chain models reveals strong links between in situ benthic species dynamics and variation in ocean pH, with calcareous species generally performing more poorly than noncalcareous species in years with low pH. The models project the long-term consequences of these dynamic changes, which predict substantial shifts in the species dominating the habitat as a consequence of both direct effects of reduced calcification and indirect effects arising from the web of species interactions. Our results indicate that pH decline is proceeding at a more rapid rate than previously predicted in some areas, and that this decline has ecological consequences for near shore benthic ecosystems.

  16. Lineage II (Serovar 1/2a and 1/2c) Human Listeria monocytogenes Pulsed-Field Gel Electrophoresis Types Divided into PFGE Groups Using the Band Patterns Below 145.5 kb.

    Science.gov (United States)

    Lopez-Valladares, Gloria; Danielsson-Tham, Marie-Louise; Goering, Richard V; Tham, Wilhelm

    2017-01-01

    Among 504 clinical lineage II isolates of Listeria monocytogenes isolated during 1958-2010 in Sweden, 119 pulsed-field gel electrophoresis (PFGE) types (AscI) have been identified based on the number and distribution of all banding patterns in each DNA profile. In this study, these types were further divided into PFGE groups based on the configuration of small bands with sizes kb. The 504 isolates included 483 serovar 1/2a isolates distributed into 114 PFGE types and 21 serovar 1/2c isolates distributed into 9 PFGE types; these were further divided into 21 PFGE groups. PFGE group, that is, configuration of small bands below 145.5 kb, and serovars were correlated. L. monocytogenes isolates belonging to PFGE groups A, B, C, E, F, H, K, L, M, S, V, W, Y, and Ö-6 to Ö-12 shared serovar 1/2a, with one exception. PFGE group E also included two PFGE types sharing serovar 1/2c and four PFGE types belonging to either serovar 1/2a or 1/2c. Isolates belonging to PFGE group N shared serovar 1/2c. In contrast to lineage I isolates, small fragments kb were visible in all L. monocytogenes isolates belonging to lineage II. In the results from both the present and previous studies, the genomic region of small bands was genetically more conservative than in large bands. The distribution of these small bands established the relatedness of strains and defined a genetic marker for both lineages I and II, while also establishing their serogroup. The division of L. monocytogenes PFGE types into PFGE groups is advantageous as the profile of every new isolate can be identified easily and quickly through first studying the PFGE group affiliation of the isolate based on the smaller band patterns kb, and then identifying the PFGE type based on the band patterns >145.5 kb.

  17. Optically controlled electrophoresis with a photoconductive substrate

    Science.gov (United States)

    Inami, Wataru; Nagashima, Taiki; Kawata, Yoshimasa

    2018-05-01

    A photoconductive substrate is used to perform electrophoresis. Light-induced micro-particle flow manipulation is demonstrated without using a fabricated flow channel. The path along which the particles were moved was formed by an illuminated light pattern on the substrate. Because the substrate conductivity and electric field distribution can be modified by light illumination, the forces acting on the particles can be controlled. This technique has potential applications as a high functionality analytical device.

  18. The first nationwide survey of MD-PhDs in the social sciences and humanities: training patterns and career choices.

    Science.gov (United States)

    Holmes, Seth M; Karlin, Jennifer; Stonington, Scott D; Gottheil, Diane L

    2017-03-21

    While several articles on MD-PhD trainees in the basic sciences have been published in the past several years, very little research exists on physician-investigators in the social sciences and humanities. However, the numbers of MD-PhDs training in these fields and the number of programs offering training in these fields are increasing, particularly within the US. In addition, accountability for the public funding for MD-PhD programs requires knowledge about this growing population of trainees and their career trajectories. The aim of this paper is to describe the first cohorts of MD-PhDs in the social sciences and humanities, to characterize their training and career paths, and to better understand their experiences of training and subsequent research and practice. This paper utilizes a multi-pronged recruitment method and novel survey instrument to examine an understudied population of MD-PhD trainees in the social sciences and humanities, many of whom completed both degrees without formal programmatic support. The survey instrument was designed to collect demographic, training and career trajectory data, as well as experiences of and perspectives on training and career. It describes their routes to professional development, characterizes obstacles to and predictors of success, and explores career trends. The average length of time to complete both degrees was 9 years. The vast majority (90%) completed a clinical residency, almost all (98%) were engaged in research, the vast majority (88%) were employed in academic institutions, and several others (9%) held leadership positions in national and international health organizations. Very few (4%) went into private practice. The survey responses supply recommendations for supporting current trainees as well as areas for future research. In general, MD-PhDs in the social sciences and humanities have careers that fit the goals of agencies providing public funding for training physician-investigators: they are involved

  19. Gel Electrophoresis and Fluorescamine Methods for the Detection of ...

    African Journals Online (AJOL)

    For the fluorescamine method, clarification was achieved by isoelectric precipitation and precipitation with acid to obtain pH 4.6 and 6% TCA soluble extracts respectively. Non-clarified samples were used for gel electrophoresis. Both methods confirmed that raw milk and milk processed at 85/15s were the most proteolysed, ...

  20. Characterization of metal/humic acid systems by Capillary Electrophoresis

    NARCIS (Netherlands)

    Staden JJ van; Hoop MAGT van den; Cleven R; LAC

    2000-01-01

    Metal-humic acid systems have been characterised applying Capillary Electrophoresis (CE). Appropriate experimental conditions with respect to carrier electrolyte, pH range, salt concentration, humic acid concentration and the applied potential, have been optimised. The influence of multivalent metal

  1. Determination of propionate in bread using capillary zone electrophoresis

    NARCIS (Netherlands)

    Ackermans, M.T.; Ackermans-Loonen, J.C.J.M; Beckers, J.L.

    1992-01-01

    A method for the determination of propionate in bread is described. The propionate was extracted from the bread with a repeated extraction procedure and measured using capillary zone electrophoresis in the indirect UV mode applying a background electrolyte of 0.005 M Tris adjusted at pH 4.6 by

  2. Spatial and temporal patterns of xylem sap pH derived from stems and twigs of Populus deltoides L.

    Science.gov (United States)

    Doug Aubrey; Justin Boyles; Laura Krysinsky; Robert Teskey

    2011-01-01

    Xylem sap pH (pHX) is critical in determining the quantity of inorganic carbon dissolved in xylem solution from gaseous [CO2] measurements. Studies of internal carbon transport have generally assumed that pHX derived from stems and twigs is similar and that pHX remains constant through time; however, no empirical studies have investigated these assumptions. If any of...

  3. Analysis of phloem protein patterns from different organs of Cucurbita maxima Duch. by matrix-assisted laser desorption/ionization time of flight mass spectroscopy combined with sodium dodecyl sulfate polyacrylamide gel electrophoresis.

    Science.gov (United States)

    Kehr, J; Haebel, S; Blechschmidt-Schneider, S; Willmitzer, L; Steup, M; Fisahn, J

    1999-02-01

    Sieve tubes mediate the long-distance transport of nutrients and signals between source and sink organs of plants. To detect mobile phloem proteins that are differentially distributed in source and sink organs of Cucurbita maxima, we used both one-dimensional gel electrophoresis (SDS-PAGE) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Both techniques revealed that phloem protein patterns depend on the sampling site: whilst several proteins were consistently observed in all phloem samples studied others appeared to occur in a organ-specific manner. For a characterization and identification of distinct phloem polypeptides, two approaches were chosen. First, protein bands resolved by SDS-PAGE were eluted from the polyacrylamide gel and the masses of the proteins were then determined by MALDI-TOF MS. Second, proteins resolved by SDS-PAGE were subjected to proteolytic degradation and the resulting peptides were analyzed by MALDI-TOF MS: the masses of the proteolytic peptides were used for a database search. By the latter approach, three mobile phloem compounds were identified as the phloem-specific protein PP2 (D.E. Bostwick et al., 1992, The Plant Cell 4, 1539-1548) a chymotrypsin and an aspartic proteinase inhibitor. None of the other polypeptides studied corresponded to any of the protein sequences present in the database. Furthermore, MALDI-TOF MS analyses indicated that some of the mobile phloem proteins occur in a covalently modified form and that the extent of the modification depends upon the plant organ.

  4. DNA electrophoresis through microlithographic arrays

    International Nuclear Information System (INIS)

    Sevick, E.M.; Williams, D.R.M.

    1996-01-01

    Electrophoresis is one of the most widely used techniques in biochemistry and genetics for size-separating charged molecular chains such as DNA or synthetic polyelectrolytes. The separation is achieved by driving the chains through a gel with an external electric field. As a result of the field and the obstacles that the medium provides, the chains have different mobilities and are physically separated after a given process time. The macroscopically observed mobility scales inversely with chain size: small molecules move through the medium quickly while larger molecules move more slowly. However, electrophoresis remains a tool that has yet to be optimised for most efficient size separation of polyelectrolytes, particularly large polyelectrolytes, e.g. DNA in excess of 30-50 kbp. Microlithographic arrays etched with an ordered pattern of obstacles provide an attractive alternative to gel media and provide wider avenues for size separation of polyelectrolytes and promote a better understanding of the separation process. Its advantages over gels are (1) the ordered array is durable and can be re-used, (2) the array morphology is ordered and can be standardized for specific separation, and (3) calibration with a marker polyelectrolyte is not required as the array is reproduced to high precision. Most importantly, the array geometry can be graduated along the chip so as to expand the size-dependent regime over larger chain lengths and postpone saturation. In order to predict the effect of obstacles upon the chain-length dependence in mobility and hence, size separation, we study the dynamics of single chains using theory and simulation. We present recent work describing: 1) the release kinetics of a single DNA molecule hooked around a point, frictionless obstacle and in both weak and strong field limits, 2) the mobility of a chain impinging upon point obstacles in an ordered array of obstacles, demonstrating the wide range of interactions possible between the chain and

  5. Short communication: Effect of the feed presentation form on the intake pattern, productive traits and rumen pH of beef cattle fed high concentrate diets

    Directory of Open Access Journals (Sweden)

    Antonio Gimeno

    2014-10-01

    Full Text Available Nutritional disorders like ruminal acidosis are common in Spanish beef production system, in which animals are fed diets with a high content in starch. This experiment studied the effect of feed presentation form (concentrate and straw offered separately, CD, or mixed in form of briquettes, BR on the pattern of intake, growth and rumen pH of beef cattle fed high concentrate diets. The experiment was performed with 40 Holstein male calves, 32 of them for determining feed intake pattern and productive rates, and the remaining 8, which were previously provided with a ruminal cannula, to monitor rumen pH in two 21-day consecutive periods following a change-over design. Animals fed BR reduced feed intake rate during the first hour after feeding (18.6 vs. 24.0% of daily intake p<0.001, but this diet promoted a lower rumen pH at all sampling times compared with CD (daily average of 5.98 vs. 6.33; p<0.001 and tended to promote a lower total feed intake (7.08 vs. 9.77 kg DM/d; p<0.001 and daily weight gain (1.43 vs. 1.76 kg/d; p=0.056. Offering the concentrate and the straw mixed in form of briquettes is not useful to prevent ruminal acidosis and improve growth, probably due to both a reduced particle size of straw and avoided self-regulation of straw intake along the day.

  6. Denaturing gradient gel electrophoresis

    International Nuclear Information System (INIS)

    Kocherginskaya, S.A.; Cann, I.K.O.; Mackie, R.I.

    2005-01-01

    It is worthwhile considering that only some 30 species make up the bulk of the bacterial population in human faeces at any one time based on the classical cultivation-based approach. The situation in the rumen is similar. Thus, it is practical to focus on specific groups of interest within the complex community. These may be the predominant or the most active species, specific physiological groups or readily identifiable (genetic) clusters of phylogenetically related organisms. Several 16S rDNA fingerprinting techniques can be invaluable for selecting and monitoring sequences or phylogenetic groups of interest and are described below. Over the past few decades, considerable attention was focussed on the identification of pure cultures of microbes on the basis of genetic polymorphisms of DNA encoding rRNA such as ribotyping, amplified fragment length polymorphism and randomly amplified polymorphic DNA. However, many of these methods require prior cultivation and are less suitable for use in analysis of complex mixed populations although important in describing cultivated microbial diversity in molecular terms. Much less attention was given to molecular characterization of complex communities. In particular, research into diversity and community structure over time has been revolutionized by the advent of molecular fingerprinting techniques for complex communities. Denaturing or temperature gradient gel electrophoresis (DGGE/TGGE) methods have been successfully applied to the analysis of human, pig, cattle, dog and rodent intestinal populations

  7. Leaf Protein Electrophoresis and Taxonomy of Species of Jatropha L. (Euphorbiaceae

    Directory of Open Access Journals (Sweden)

    Olaniran Temitope OLADIPO

    2012-08-01

    Full Text Available The systematic relationship existing among members of the all important genus Jatropha was studied using leaf protein electrophoresis. The aim was to identify possible taxonomic importance of the protein profile in the estimation and elucidation of the taxonomic affinity of the six species of Jatropha (Jatropha curcas Linn., J. podagrica Hook., J. gossypifolia Linn., J. mutifida Linn., J. tanjorensis Ellis & Saroja and J. integerrima Linn. found in Nigeria. The species were screened for total protein banding patterns using gel electrophoresis. Young leaves (0.8 g of the plants were washed with distilled water and macerated with sterile mortar and pestle in 0.8% Phosphate Buffer-Saline (PBS containing 0.4 M NaCl at pH 8.0. Results reveal that protein banding pattern was taxon specific. Generic band occurs at 8.3. The highest number of interspecific bands (4 exists between J. podagrica and J. multifida. Variations exist not only in the number of bands but also in the intensity of the bands. Sokal and Sneath coefficient of similarity ranges between 11.1-44.4 %. Single linkage Cluster Analysis (SLCA of the relative mobility values of the protein in the taxa shows partial agreement with current sub generic and sectional delimitation of the species based on morphology and anatomy of the species.

  8. DNA typing by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, N.

    1997-10-08

    Capillary electrophoresis is becoming more and more important in nucleic acid analysis including DNA sequencing, typing and disease gene measurements. This work summarized the background of DNA typing. The recent development of capillary electrophoresis was also discussed. The second part of the thesis showed the principle of DNA typing based on using the allelic ladder as the absolute standard ladder in capillary electrophoresis system. Future work will be focused on demonstrating DNA typing on multiplex loci and examples of disease diagnosis in the on-line format of PCR-CE. Also capillary array electrophoresis system should allow high throughput, fast speed DNA typing. Only the introduction and conclusions for this report are available here. A reprint was removed for separate processing.

  9. Biomedical applications of capillary electrophoresis

    International Nuclear Information System (INIS)

    Kartsova, L A; Bessonova, E A

    2015-01-01

    The review deals with modern analytical approaches used in capillary electrophoresis for solving medical and biological problems: search for biomarkers of various diseases and rapid diagnosis based on characteristic profiles of biologically active compounds by capillary electrophoresis with mass spectrometric detection; monitoring of the residual drugs in biological fluids for evaluating the efficiency of drug therapy; testing of the enantiomeric purity of pharmaceutical products; the use of novel materials as components of stationary and pseudo-stationary phases in capillary electrophoresis and capillary electrochromatography to increase the selectivity of separation of components of complex matrices; and identification of various on-line preconcentration techniques to reduce the detection limits of biologically active analytes. A topical trend in capillary electrophoresis required in clinical practice, viz., the design of microfluidic systems, is discussed. The bibliography includes 173 references

  10. Stair-Step Pattern of Soil Bacterial Diversity Mainly Driven by pH and Vegetation Types Along the Elevational Gradients of Gongga Mountain, China.

    Science.gov (United States)

    Li, Jiabao; Shen, Zehao; Li, Chaonan; Kou, Yongping; Wang, Yansu; Tu, Bo; Zhang, Shiheng; Li, Xiangzhen

    2018-01-01

    Ecological understandings of soil bacterial community succession and assembly mechanism along elevational gradients in mountains remain not well understood. Here, by employing the high-throughput sequencing technique, we systematically examined soil bacterial diversity patterns, the driving factors, and community assembly mechanisms along the elevational gradients of 1800-4100 m on Gongga Mountain in China. Soil bacterial diversity showed an extraordinary stair-step pattern along the elevational gradients. There was an abrupt decrease of bacterial diversity between 2600 and 2800 m, while no significant change at either lower (1800-2600 m) or higher (2800-4100 m) elevations, which coincided with the variation in soil pH. In addition, the community structure differed significantly between the lower and higher elevations, which could be primarily attributed to shifts in soil pH and vegetation types. Although there was no direct effect of MAP and MAT on bacterial community structure, our partial least squares path modeling analysis indicated that bacterial communities were indirectly influenced by climate via the effect on vegetation and the derived effect on soil properties. As for bacterial community assembly mechanisms, the null model analysis suggested that environmental filtering played an overwhelming role in the assembly of bacterial communities in this region. In addition, variation partition analysis indicated that, at lower elevations, environmental attributes explained much larger fraction of the β-deviation than spatial attributes, while spatial attributes increased their contributions at higher elevations. Our results highlight the importance of environmental filtering, as well as elevation-related spatial attributes in structuring soil bacterial communities in mountain ecosystems.

  11. Characterization of Seed Storage Proteins from Chickpea Using 2D Electrophoresis Coupled with Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Pramod Kumar Singh

    2016-01-01

    Full Text Available Proteomic analysis was employed to map the seed storage protein network in landrace and cultivated chickpea accessions. Protein extracts were separated by two-dimensional gel electrophoresis (2D-GE across a broad range 3.0–10.0 immobilized pH gradient (IPG strips. Comparative elucidation of differentially expressed proteins between two diverse geographically originated chickpea accessions was carried out using 2D-GE coupled with mass spectrometry. A total of 600 protein spots were detected in these accessions. In-gel protein expression patterns revealed three protein spots as upregulated and three other as downregulated. Using trypsin in-gel digestion, these differentially expressed proteins were identified by matrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF-MS which showed 45% amino acid homology of chickpea seed storage proteins with Arabidopsis thaliana.

  12. Analysis of Two-Dimensional Electrophoresis Gel Images

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2002-01-01

    This thesis describes and proposes solutions to some of the currently most important problems in pattern recognition and image analysis of two-dimensional gel electrophoresis (2DGE) images. 2DGE is the leading technique to separate individual proteins in biological samples with many biological...

  13. The single-cell gel electrophoresis assay to determine apoptosis ...

    African Journals Online (AJOL)

    When the frequency of appearance of apoptotic cells following was observed over a period of time, there was a significant increase in appearance of apoptosis when using single cell gel electrophoresis assay. The present report demonstrates that the characteristic pattern of apoptotic comets detected by the comet assay ...

  14. Preparation of Barley Storage Protein, Hordein, for Analytical Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis

    DEFF Research Database (Denmark)

    Doll, Hans; Andersen, Bente

    1981-01-01

    The extraction, reduction, and alkylation of barley hordein for routine electrophoresis in sodium dodecyl sulfate-polyacrylamide gels were studied to set up a simple preparation procedure giving well-resolved bands in the electrophoresis gel. Hordein was extracted from single crushed seeds or flour...... by aqueous 50% propan-2-ol containing a Tris-borate buffer, pH 8.6. The presence of the buffer facilitates the consecutive complete reduction of the extracted protein in the alcohol. Reduction and alkylation in the buffer containing propan-2-ol give sharper bands in the electrophoresis than reduction...

  15. Bioprocessing: Prospects for space electrophoresis

    Science.gov (United States)

    Bier, M.

    1977-01-01

    The basic principles of electrophoresis are reviewed in light of its past contributions to biology and medicine. The near-zero gravity environment of orbiting spacecraft may present some unique advantages for a variety of processes, by abolishing the major source of convection in fluids. As the ground-based development of electrophoresis was heavily influenced by the need to circumvent the effects of gravity, this process should be a prime candidate for space operation. Nevertheless, while a space facility for electrophoresis may overcome the limitations imposed by gravity, it will not necessarily overcome all problems inherent in electrophoresis. These are, mainly, electroosmosis and the dissipation of the heat generated by the electric field. The NASA program has already led to excellent coatings to prevent electroosmosis, while the need for heat dissipation will continue to impose limits on the actual size of equipment. It is also not excluded that, once the dominant force of gravity is eliminated, disturbances in fluid stability may originate from weaker forces, such as surface tension.

  16. Gel electrophoresis of inorganic cations

    International Nuclear Information System (INIS)

    Schoenhofer, F.; Grass, F.

    1978-01-01

    In order to be able to separate the largest possible amounts of substance, polyacryl amide gel (PAA) and silica gel are used as carrier for the electrophoresis. Milligramme quantities can easily be separated on PAA gel plates. Electrophoretic ion focussing considerably improves it. Separations of Sr/Y and lanthanoids were carried out. The behaviour of the readily soluble complexing agent acids on silica gel thin layers was minutely investigated and an interpretation of the focussing effect was derived. The conditions for separating radionuclides were optimized. A further improved separation can be achieved by a time sequence combination of normal electrophoresis and ion focussing. Selective isolation methods are advantageous to determine radionuclide traces in environmental samples. The selective adsorption on preformed deposits was transferred to electrophoresis. After pre-investigations on silica gel layers, strontium and barium could also be retained on PAA gel and radium on strontium sulphate in PAA, whereas the disturbing calcium can easily pass through. Cesium can also be retained by prussian blue in the electrophoresis. (orig.) [de

  17. PH sensor

    OpenAIRE

    Artero, C.; Nogueras Cervera, Marc; Manuel Lázaro, Antonio

    2012-01-01

    This paper presents a design of a marine instrument for the measurement of pH in seawater. The measurement system consists of a pH electrode connected to the underwater observatory OBSEA. The extracted data are useful for scientists researching ocean acidification. Peer Reviewed

  18. Electrophoresis in strong electric fields.

    Science.gov (United States)

    Barany, Sandor

    2009-01-01

    Two kinds of non-linear electrophoresis (ef) that can be detected in strong electric fields (several hundred V/cm) are considered. The first ("classical" non-linear ef) is due to the interaction of the outer field with field-induced ionic charges in the electric double layer (EDL) under conditions, when field-induced variations of electrolyte concentration remain to be small comparatively to its equilibrium value. According to the Shilov theory, the non-linear component of the electrophoretic velocity for dielectric particles is proportional to the cubic power of the applied field strength (cubic electrophoresis) and to the second power of the particles radius; it is independent of the zeta-potential but is determined by the surface conductivity of particles. The second one, the so-called "superfast electrophoresis" is connected with the interaction of a strong outer field with a secondary diffuse layer of counterions (space charge) that is induced outside the primary (classical) diffuse EDL by the external field itself because of concentration polarization. The Dukhin-Mishchuk theory of "superfast electrophoresis" predicts quadratic dependence of the electrophoretic velocity of unipolar (ionically or electronically) conducting particles on the external field gradient and linear dependence on the particle's size in strong electric fields. These are in sharp contrast to the laws of classical electrophoresis (no dependence of V(ef) on the particle's size and linear dependence on the electric field gradient). A new method to measure the ef velocity of particles in strong electric fields is developed that is based on separation of the effects of sedimentation and electrophoresis using videoimaging and a new flowcell and use of short electric pulses. To test the "classical" non-linear electrophoresis, we have measured the ef velocity of non-conducting polystyrene, aluminium-oxide and (semiconductor) graphite particles as well as Saccharomice cerevisiae yeast cells as a

  19. Western Blotting using Capillary Electrophoresis

    OpenAIRE

    Anderson, Gwendolyn J.; Cipolla, Cynthia; Kennedy, Robert T.

    2011-01-01

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein a...

  20. Capillary electrophoresis systems and methods

    Science.gov (United States)

    Dorairaj, Rathissh [Hillsboro, OR; Keynton, Robert S [Louisville, KY; Roussel, Thomas J [Louisville, KY; Crain, Mark M [Georgetown, IN; Jackson, Douglas J [New Albany, IN; Walsh, Kevin M [Louisville, KY; Naber, John F [Goshen, KY; Baldwin, Richard P [Louisville, KY; Franco, Danielle B [Mount Washington, KY

    2011-08-02

    An embodiment of the invention is directed to a capillary electrophoresis apparatus comprising a plurality of separation micro-channels. A sample loading channel communicates with each of the plurality of separation channels. A driver circuit comprising a plurality of electrodes is configured to induce an electric field across each of the plurality of separation channels sufficient to cause analytes in the samples to migrate along each of the channels. The system further comprises a plurality of detectors configured to detect the analytes.

  1. DNA Sequencing by Capillary Electrophoresis

    Science.gov (United States)

    Karger, Barry L.; Guttman, Andras

    2009-01-01

    Sequencing of human and other genomes has been at the center of interest in the biomedical field over the past several decades and is now leading toward an era of personalized medicine. During this time, DNA sequencing methods have evolved from the labor intensive slab gel electrophoresis, through automated multicapillary electrophoresis systems using fluorophore labeling with multispectral imaging, to the “next generation” technologies of cyclic array, hybridization based, nanopore and single molecule sequencing. Deciphering the genetic blueprint and follow-up confirmatory sequencing of Homo sapiens and other genomes was only possible by the advent of modern sequencing technologies that was a result of step by step advances with a contribution of academics, medical personnel and instrument companies. While next generation sequencing is moving ahead at break-neck speed, the multicapillary electrophoretic systems played an essential role in the sequencing of the Human Genome, the foundation of the field of genomics. In this prospective, we wish to overview the role of capillary electrophoresis in DNA sequencing based in part of several of our articles in this journal. PMID:19517496

  2. Comparison of protein patterns of xrs-5, a radiosensitive Chinese hamster ovary cell line, and CHO-K1, its radioresistant parent, using two-dimensional gel-electrophoresis

    International Nuclear Information System (INIS)

    Kramer, J.M.

    1991-01-01

    X-ray sensitive strains of Chinese hamster ovary cell lines have been used to analyze radiation repair mechanisms. One cell line, xrs-5, has been shown to be very sensitive to ionizing radiation and radical forming chemical mutagens. This sensitivity is thought to be a result a mutation in the DNA double strand break (DSB) repair mechanism, and its characterization has been a goal of several repair mechanism studies. Using two-dimensional gel electrophoresis, we have detected a protein (MW approximately 55KD) in the DNA/Nuclear Matrix (nucleoid) cell fraction of CHO-Kl cells that is absent in the nucleoid fraction of xrs-5. This protein is present, however, in both CHO-Kl and xrs-5 whole cell protein maps. To determine whether the 55KD protein is responsible for the radiosensitive and defective DSB repair phenotype of xrs-5 cells, studies are now underway to analyze revertants of xrs-5 that are proficient in DSB repair. Furthermore, an effort to sequence the protein in question is planned. 23 refs., 2 figs

  3. Separation and determination of some carboxylic acids by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Sladkov, V.; Fourest, B

    2006-07-01

    Separation and determination of some organic acids, mono-carboxylic (formic and acetic), dicarboxylic (oxalic and tartaric), tricarboxylic (citric) acids and aromatic acids (phtalic, benzoic, mellitic and trimellitic), by capillary electrophoresis are reviewed. The method development parameters, such as separation and injection mode, are discussed. Special attention is paid to the comparison of different detection types (spectroscopic and electrochemical). The optimisation of the carrier electrolyte composition (choice of carrier electrolyte, effect of pH, ionic strength, electro-osmotic flow modifier) is treated. Different additives (alkali-earth and transition metal ions, cyclodextrins and alcohol), which are often used for improving organic acid separation, are also considered. (authors)

  4. Separation and determination of some carboxylic acids by capillary electrophoresis

    International Nuclear Information System (INIS)

    Sladkov, V.; Fourest, B.

    2006-01-01

    Separation and determination of some organic acids, mono-carboxylic (formic and acetic), dicarboxylic (oxalic and tartaric), tricarboxylic (citric) acids and aromatic acids (phtalic, benzoic, mellitic and trimellitic), by capillary electrophoresis are reviewed. The method development parameters, such as separation and injection mode, are discussed. Special attention is paid to the comparison of different detection types (spectroscopic and electrochemical). The optimisation of the carrier electrolyte composition (choice of carrier electrolyte, effect of pH, ionic strength, electro-osmotic flow modifier) is treated. Different additives (alkali-earth and transition metal ions, cyclodextrins and alcohol), which are often used for improving organic acid separation, are also considered. (authors)

  5. Western blotting using capillary electrophoresis.

    Science.gov (United States)

    Anderson, Gwendolyn J; M Cipolla, Cynthia; Kennedy, Robert T

    2011-02-15

    A microscale Western blotting system based on separating sodium-dodecyl sulfate protein complexes by capillary gel electrophoresis followed by deposition onto a blotting membrane for immunoassay is described. In the system, the separation capillary is grounded through a sheath capillary to a mobile X-Y translation stage which moves a blotting membrane past the capillary outlet for protein deposition. The blotting membrane is moistened with a methanol and buffer mixture to facilitate protein adsorption. Although discrete protein zones could be detected, bands were broadened by ∼1.7-fold by transfer to membrane. A complete Western blot for lysozyme was completed in about one hour with 50 pg mass detection limit from low microgram per milliliter samples. These results demonstrate substantial reduction in time requirements and improvement in mass sensitivity compared to conventional Western blots. Western blotting using capillary electrophoresis shows promise to analyze low volume samples with reduced reagents and time, while retaining the information content of a typical Western blot.

  6. Conducting polymer electrodes for gel electrophoresis.

    Directory of Open Access Journals (Sweden)

    Katarina Bengtsson

    Full Text Available In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene (PEDOT can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  7. Conducting polymer electrodes for gel electrophoresis.

    Science.gov (United States)

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that π-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel electrophoresis, and show that electrodes containing PEDOT can be used with a commercial polyacrylamide gel electrophoresis system with minimal impact to the resulting gel image or the ionic transport measured during a separation.

  8. Technical improvement to prevent DNA degradation of Leptospira spp. in pulsed field gel electrophoresis.

    Science.gov (United States)

    Ribeiro, R L; Machry, L; Brazil, J M V; Ramos, T M V; Avelar, K E S; Pereira, M M

    2009-08-01

    Leptospirosis is a public health problem. Infection with pathogenic Leptospira occurs by exposure to many environments and is traditionally associated with occupational risk activities. Pulsed-field gel electrophoresis was used to investigate the epidemiological relatedness among Leptospira isolates. However, analysis by PFGE yielded inconclusive data as a result of extensive DNA degradation. This degradation can be significantly reduced by the inclusion of thiourea in the electrophoresis buffer, improving the analysis of DNA banding patterns.

  9. Determination of monosaccharides derivatized with 2-aminobenzoic Acid by capillary electrophoresis.

    Science.gov (United States)

    Abo, Mitsuru; He, Li-Ping; Sato, Kae; Okubo, Akira

    2013-01-01

    Reducing monosaccharides were derivatized with 2-aminobenzoic acid (2-AA) through reductive amination using sodium cyanoborohydride as a reductant, and the derivatives were separated by capillary zone electrophoresis with UV detection using 50 mM sodium phosphate (pH 5.5) or 150 mM sodium borate-50 mM sodium phosphate (pH 7.0) running buffer. The derivatives of monosaccharides, which are major components of various carbohydrate materials, were completely separated within 25 min.

  10. Multilocus Variable-Number Tandem-Repeat Analysis, Pulsed-Field Gel Electrophoresis, and Antimicrobial Susceptibility Patterns in Discrimination of Sporadic and Outbreak-Related Strains of Yersinia enterocolitica

    Directory of Open Access Journals (Sweden)

    Skurnik Mikael

    2011-02-01

    Full Text Available Abstract Background We assessed the potential of multilocus variable-number tandem-repeat analysis (MLVA, pulsed-field gel electrophoresis (PFGE, and antimicrobial susceptibility testing for discriminating 104 sporadic and outbreak-related Yersinia enterocolitica (YE bio/serotype 3-4/O:3 and 2/O:9 isolates. MLVA using six VNTR markers was performed in two separate multiplex PCRs, and the fluorescently labeled PCR products were accurately sized on an automated DNA sequencer. Results MLVA discriminated 82 sporadic YE 3-4/O:3 and 2/O:9 strains into 77 types, whereas PFGE with the restriction enzyme NotI discriminated the strains into 23 different PFGE pulsotypes. The discriminatory index for a sporadic strain was 0.862 for PFGE and 0.999 for MLVA. MLVA confirmed that a foodborne outbreak in the city of Kotka, Finland in 2003 had been caused by a multiresistant YE 4/O:3 strain that was distinctly different from those of epidemiologically unrelated strains with an identical PFGE pulsotype. The multiresistance of Y. enterocolitica strains (19% of the sporadic strains correlated significantly (p = 0.002 with travel abroad. All of the multiresistant Y. enterocolitica strains belonged to four PFGE pulsotypes that did not contain any susceptible strains. Resistance to nalidixic acid was related to changes in codons 83 or 87 that stemmed from mutations in the gyrA gene. The conjugation experiments demonstrated that resistance to CHL, STR, and SUL was carried by a conjugative plasmid. Conclusions MLVA using six loci had better discriminatory power than PFGE with the NotI enzyme. MLVA was also a less labor-intensive method than PFGE and the results were easier to analyze. The conjugation experiments demonstrated that a resistance plasmid can easily be transferred between Y. enterocolitica strains. Antimicrobial multiresistance of Y. enterocolitica strains was significantly associated with travel abroad.

  11. Supramolecular gel electrophoresis of large DNA fragments.

    Science.gov (United States)

    Tazawa, Shohei; Kobayashi, Kazuhiro; Oyoshi, Takanori; Yamanaka, Masamichi

    2017-10-01

    Pulsed-field gel electrophoresis is a frequent technique used to separate exceptionally large DNA fragments. In a typical continuous field electrophoresis, it is challenging to separate DNA fragments larger than 20 kbp because they migrate at a comparable rate. To overcome this challenge, it is necessary to develop a novel matrix for the electrophoresis. Here, we describe the electrophoresis of large DNA fragments up to 166 kbp using a supramolecular gel matrix and a typical continuous field electrophoresis system. C 3 -symmetric tris-urea self-assembled into a supramolecular hydrogel in tris-boric acid-EDTA buffer, a typical buffer for DNA electrophoresis, and the supramolecular hydrogel was used as a matrix for electrophoresis to separate large DNA fragments. Three types of DNA marker, the λ-Hind III digest (2 to 23 kbp), Lambda DNA-Mono Cut Mix (10 to 49 kbp), and Marker 7 GT (10 to 165 kbp), were analyzed in this study. Large DNA fragments of greater than 100 kbp showed distinct mobility using a typical continuous field electrophoresis system. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Analytical biotechnology: Capillary electrophoresis and chromatography

    International Nuclear Information System (INIS)

    Horvath, C.; Nikelly, J.G.

    1990-01-01

    The papers describe the separation, characterization, and equipment required for the electrophoresis or chromatography of cyclic nucleotides, pharmaceuticals, therapeutic proteins, recombinant DNA products, pheromones, peptides, and other biological materials. One paper, On-column radioisotope detection for capillary electrophoresis, has been indexed separately for inclusion on the data base

  13. Quantification of DNA damage by single-cell electrophoresis

    International Nuclear Information System (INIS)

    Ikushima, Takaji

    1990-01-01

    A simple technique of micro-agarose gel electrophoresis has been developed to quantify DNA damage in individual cells. Cells are embedded in agarose gel on microscope slides, lysed by detergents and then electrophoresed for a short time under neutral or alkaline condition. In irradiated cells, DNA migrates from the nucleus toward the anode, displaying commet-like pattern by staining with DNA-specific fluorescence dye. DNA damage is evaluated by measuring the distance of DNA migration. The technique was applied for measuring DNA damage in single cells exposed to 60 Co γ-rays, or to KUR radiation in the presence or absence of 10 B-enriched boric acid. The enhanced production of double-stranded DNA breaks by 10 B(n,α) 7 Li reaction was demonstrated here. The significant increase in the length of DNA migration was observed in single cells exposed to such a low dose as 20 cGy after alkaline micro electrophoresis. (author)

  14. Research on pre-staining gel electrophoresis

    International Nuclear Information System (INIS)

    Zhong Ruibo; Liu Yushuang; Zhang Ping; Liu Jingran; Zhao Guofen; Zhang Feng

    2014-01-01

    Background: Gel electrophoresis is a powerful biochemical separation technique. Most biological molecules are completely transparent in the visible region of light, so it is necessary to use staining to show the results after gel electrophoresis, and the general steps of conventional staining methods are time-consuming. Purpose: We try to develop a novel approach to simplify the gel electrophoresis: Pre-Staining Gel Electrophoresis (PSGE), which can make the gel electrophoresis results monitored in real time. Methods: Pre-stain the protein samples with Coomassie Brilliant Blue (CBB) for 30 min before loading the sample into the gel well. Results and Conclusion: PSGE can be successfully used to analyze the binding efficiency of Bovine Serum Albumin (BSA) and amphiphilic polymer via chemical coupling and physical absorption, and the double PSGE also shows a great potential in bio-analytical chemistry. (authors)

  15. [Determination of glutamic acid in biological material by capillary electrophoresis].

    Science.gov (United States)

    Narezhnaya, E; Krukier, I; Avrutskaya, V; Degtyareva, A; Igumnova, E A

    2015-01-01

    The conditions for the identification and determination of Glutamic acid by capillary zone electrophoresis without their preliminary derivatization have been optimized. The effect of concentration of buffer electrolyte and pH on determination of Glutamic acid has been investigated. It is shown that the 5 Mm borate buffer concentration and a pH 9.15 are optimal. Quantitative determination of glutamic acid has been carried out using a linear dependence between the concentration of the analyte and the area of the peak. The accuracy and reproducibility of the determination are confirmed by the method "introduced - found". Glutamic acid has been determined in the placenta homogenate. The duration of analysis doesn't exceed 30 minutes. The results showed a decrease in the level of glutamic acid in cases of pregnancy complicated by placental insufficiency compared with the physiological, and this fact allows to consider the level of glutamic acid as a possible marker of complicated pregnancy.

  16. Capillary electrophoresis and nanomaterials - Part I: Capillary electrophoresis of nanomaterials.

    Science.gov (United States)

    Adam, Vojtech; Vaculovicova, Marketa

    2017-10-01

    Nanomaterials are in analytical science used for a broad range of purposes, covering the area of sample pretreatment as well as separation, detection, and identification of target molecules. This part of the review covers capillary electrophoresis (CE) of nanomaterials and focuses on the application of CE as a method for characterization used during nanomaterial synthesis and modification as well as the monitoring of their properties and interactions with other molecules. The heterogeneity of the nanomaterial family is extremely large. Depending on different definitions of the term Nanomaterial/Nanoparticle, the group may cover metal and polymeric nanoparticles, carbon nanomaterials, liposomes and even dendrimers. Moreover, these nanomaterials are usually subjected to some kind of surface modification or functionalization, which broadens the diversity even more. Not only for purposes of verification of nanomaterial synthesis and batch-to-batch quality check, but also for determination the polydispersity and for functionality characterization on the nanoparticle surface, has CE offered very beneficial capabilities. Finally, the monitoring of interactions between nanomaterials and other (bio)molecules is easily performed by some kind of capillary electromigration technique. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Fabricating PFPE Membranes for Capillary Electrophoresis

    Science.gov (United States)

    Lee, Michael C.; Willis, Peter A.; Greer, Frank; Rolland, Jason

    2009-01-01

    A process has been developed for fabricating perfluoropolyether (PFPE) membranes that contain microscopic holes of precise sizes at precise locations. The membranes are to be incorporated into laboratory-on-a-chip microfluidic devices to be used in performing capillary electrophoresis. The present process is a modified version of part of the process, described in the immediately preceding article, that includes a step in which a liquid PFPE layer is cured into solid (membrane) form by use of ultraviolet light. In the present process, one exploits the fact that by masking some locations to prevent exposure to ultraviolet light, one can prevent curing of the PFPE in those locations. The uncured PFPE can be washed away from those locations in the subsequent release and cleaning steps. Thus, holes are formed in the membrane in those locations. The most straightforward way to implement the modification is to use, during the ultraviolet-curing step, an ultraviolet photomask similar to the photomasks used in fabricating microelectronic devices. In lieu of such a photomask, one could use a mask made of any patternable ultraviolet-absorbing material (for example, an ink or a photoresist).

  18. Old but Still Relevant: High Resolution Electrophoresis and Immunofixation in Multiple Myeloma.

    Science.gov (United States)

    Misra, Aroonima; Mishra, Jyoti; Chandramohan, Jagan; Sharma, Atul; Raina, Vinod; Kumar, Rajive; Soni, Sushant; Chopra, Anita

    2016-03-01

    High resolution electrophoresis (HRE) and immunofixation (IFX) of serum and urine are integral to the diagnostic work-up of multiple myeloma. Unusual electrophoresis patterns are common and may be misinterpreted. Though primarily the responsibility of the hematopathologist, clinicians who are responsible for managing myelomas may benefit from knowledge of these. In this review article we intend to discuss the patterns and importance of electrophoresis in present day scenario. Patterns of HRE and IFX seen in our laboratory over the past 15 years were studied. Monoclonal proteins are seen on HRE as sharply defined bands, sometimes two, lying from γ- to α-globulin regions on a background of normal, increased or decreased polyclonal γ-globulins, showing HRE to be a rapid and dependable method of detecting M-protein in serum or urine. Immunofixation complements HRE and due to its greater sensitivity, is able to pick up small or light chain bands, not apparent on electrophoresis, including biclonal disease even when electrophoresis shows only one M-band. Special features liable to misinterpretation are discussed. Familiarity with the interpretation of the varied patterns seen in health and disease is essential for providing dependable laboratory support in the management of multiple myeloma.

  19. Comparison of non-electrophoresis grade with electrophoresis grade BIS in NIPAM polymer gel preparation

    Science.gov (United States)

    Khodadadi, Roghayeh; Khajeali, Azim; Farajollahi, Ali Reza; Hajalioghli, Parisa; Raeisi, Noorallah

    2015-01-01

    Introduction:The main objective of this study was to investigate the possibility of replacing electrophoresis cross-linker with non-electrophoresis N, N′-methylenebisacrylamide (BIS) in N-isopropyl acrylamide (NIPAM) polymer gel and its possible effect on dose response. Methods: NIPAM polymer gel was prepared from non-electrophoresis grade BIS and the relaxation rate (R2) was measured by MR imaging after exposing the gel to gamma radiation from Co-60 source. To compare the response of this gel with the one that contains electrophoresis grade BIS, two sets of NIPAM gel were prepared using electrophoresis and non-electrophoresis BIS and irradiated to different gamma doses. Results: It was found that the dose–response of NIPAM gel made from the non-electrophoresis grade BIS is coincident with that of electrophoresis grade BIS. Conclusion:Taken all, it can be concluded that the non-electrophoresis grade BIS not only is a suitable alternative for the electrophoresis grade BIS but also reduces the cost of gel due to its lower price. PMID:26457250

  20. Agarose gel electrophoresis for the separation of DNA fragments.

    Science.gov (United States)

    Lee, Pei Yun; Costumbrado, John; Hsu, Chih-Yuan; Kim, Yong Hoon

    2012-04-20

    Agarose gel electrophoresis is the most effective way of separating DNA fragments of varying sizes ranging from 100 bp to 25 kb(1). Agarose is isolated from the seaweed genera Gelidium and Gracilaria, and consists of repeated agarobiose (L- and D-galactose) subunits(2). During gelation, agarose polymers associate non-covalently and form a network of bundles whose pore sizes determine a gel's molecular sieving properties. The use of agarose gel electrophoresis revolutionized the separation of DNA. Prior to the adoption of agarose gels, DNA was primarily separated using sucrose density gradient centrifugation, which only provided an approximation of size. To separate DNA using agarose gel electrophoresis, the DNA is loaded into pre-cast wells in the gel and a current applied. The phosphate backbone of the DNA (and RNA) molecule is negatively charged, therefore when placed in an electric field, DNA fragments will migrate to the positively charged anode. Because DNA has a uniform mass/charge ratio, DNA molecules are separated by size within an agarose gel in a pattern such that the distance traveled is inversely proportional to the log of its molecular weight(3). The leading model for DNA movement through an agarose gel is "biased reptation", whereby the leading edge moves forward and pulls the rest of the molecule along(4). The rate of migration of a DNA molecule through a gel is determined by the following: 1) size of DNA molecule; 2) agarose concentration; 3) DNA conformation(5); 4) voltage applied, 5) presence of ethidium bromide, 6) type of agarose and 7) electrophoresis buffer. After separation, the DNA molecules can be visualized under uv light after staining with an appropriate dye. By following this protocol, students should be able to: Understand the mechanism by which DNA fragments are separated within a gel matrix Understand how conformation of the DNA molecule will determine its mobility through a gel matrix Identify an agarose solution of appropriate

  1. Electrophoresis in space at zero gravity

    Science.gov (United States)

    Bier, M.; Snyder, R. S.

    1974-01-01

    Early planning for manufacturing operations in space include the use of electrophoresis for purification and separation of biological materials. Greatly simplified electrophoresis apparatus have been flown in the Apollo 14 and 16 missions to test the possibility of stable liquid systems in orbit. Additionally, isoelectric focusing and isotachophoresis are of particular interest as they offer very high resolution and have self-sharpening boundaries. The value of possible space electrophoresis is substantial. For example, present technology permits large fractionation of only a few of blood proteins many fractions, and separated cell populations are needed for research.

  2. Human lymphocyte polymorphisms detected by quantitative two-dimensional electrophoresis

    International Nuclear Information System (INIS)

    Goldman, D.; Merril, C.R.

    1983-01-01

    A survey of 186 soluble lymphocyte proteins for genetic polymorphism was carried out utilizing two-dimensional electrophoresis of 14 C-labeled phytohemagglutinin (PHA)-stimulated human lymphocyte proteins. Nineteen of these proteins exhibited positional variation consistent with independent genetic polymorphism in a primary sample of 28 individuals. Each of these polymorphisms was characterized by quantitative gene-dosage dependence insofar as the heterozygous phenotype expressed approximately 50% of each allelic gene product as was seen in homozygotes. Patterns observed were also identical in monozygotic twins, replicate samples, and replicate gels. The three expected phenotypes (two homozygotes and a heterozygote) were observed in each of 10 of these polymorphisms while the remaining nine had one of the homozygous classes absent. The presence of the three phenotypes, the demonstration of gene-dosage dependence, and our own and previous pedigree analysis of certain of these polymorphisms supports the genetic basis of these variants. Based on this data, the frequency of polymorphic loci for man is: P . 19/186 . .102, and the average heterozygosity is .024. This estimate is approximately 1/3 to 1/2 the rate of polymorphism previously estimated for man in other studies using one-dimensional electrophoresis of isozyme loci. The newly described polymorphisms and others which should be detectable in larger protein surveys with two-dimensional electrophoresis hold promise as genetic markers of the human genome for use in gene mapping and pedigree analyses

  3. Development of two dimensional electrophoresis method using single chain DNA

    International Nuclear Information System (INIS)

    Ikeda, Junichi; Hidaka, So

    1998-01-01

    By combining a separation method due to molecular weight and a method to distinguish difference of mono-bases, it was aimed to develop a two dimensional single chain DNA labeled with Radioisotope (RI). From electrophoretic pattern difference of parent and variant strands, it was investigated to isolate the root module implantation control gene. At first, a Single Strand Conformation Polymorphism (SSCP) method using concentration gradient gel was investigated. As a result, it was formed that intervals between double chain and single chain DNAs expanded, but intervals of both single chain DNAs did not expand. On next, combination of non-modified acrylic amide electrophoresis method and Denaturing Gradient-Gel Electrophoresis (DGGE) method was examined. As a result, hybrid DNA developed by two dimensional electrophoresis arranged on two lines. But, among them a band of DNA modified by high concentration of urea could not be found. Therefore, in this fiscal year's experiments, no preferable result could be obtained. By the used method, it was thought to be impossible to detect the differences. (G.K.)

  4. Plasma protein electrophoresis of Trachemys scripta and Iguana iguana.

    Science.gov (United States)

    Giménez, Mercè; Saco, Yolanda; Pato, Raquel; Busquets, Alex; Martorell, Jaime M; Bassols, Anna

    2010-06-01

    Protein electrophoresis is widely applied in veterinary medicine, but is not used often in reptiles, in part because of lack of reference values. The goals of this study were to compare plasma protein profiles obtained by cellulose acetate electrophoresis (CAE) and agarose gel electrophoresis (AGE), measure precision and examine interference by sample hemolysis, and establish preliminary reference intervals for 2 reptile species. Heparinized plasma samples from healthy and diseased adult female Iguana iguana (n=40) and Trachemys scripta (n=60) were analyzed by CAE and AGE. Total protein concentration was measured by the biuret method. Electrophoresis results were compared using Bland-Altman plots and Passing-Bablok regression analysis. Precision and the effects of sample hemolysis were determined. Results from clinically healthy animals were used to determine reference intervals. Five protein fractions were identified in both species, with bisalbuminemia observed in 23/40 iguanas. High correlation was observed between the 2 methods for all fractions, with few proportional and systematic errors. Coefficients of variation were lower using AGE vs CAE and for I. iguana vs T. scripta. Two additional bands were observed in hemolyzed samples from T. scripta; 1 additional band was observed for I. iguana. Minimum and maximum values were reported for healthy I. iguana (n=14) and T. scripta (n=22). Although both methods are acceptable, the performance of AGE was slightly better than that of CAE for analysis of plasma from reptiles. Furthermore, reptile electrophoretic patterns should be interpreted based on the method used, the species analyzed, and the quality of the plasma sample.

  5. Characterization of asphaltenes by nonaqueous capillary electrophoresis

    NARCIS (Netherlands)

    Kok, W.T.; Tüdös, A.J.; Grutters, M.; Shepherd, A.G.

    2011-01-01

    Nonaqueous capillary electrophoresis was used for the separation and characterization of asphaltene samples from different sources. For the separation medium (background electrolyte), mixtures of tetrahydrofuran and a high-permittivity organic solvent could be used. The best results were obtained

  6. Analysis of rRNA gene methylation in Arabidopsis thaliana by CHEF-Conventional 2D gel electrophoresis

    Science.gov (United States)

    Mohannath, Gireesha; Pikaard, Craig S.

    2017-01-01

    Summary Contour-clamped homogenous electric field (CHEF) gel electrophoresis, a variant of Pulsed-field gel electrophoresis (PFGE), is a powerful technique for resolving large fragments of DNA (10 kb to 9 Mb). CHEF has many applications including the physical mapping of chromosomes, artificial chromosomes and sub-chromosomal DNA fragments, etc. Here we describe the use of CHEF and two-dimensional gel electrophoresis to analyze rRNA gene methylation patterns within the two ~ 4 million base pair nucleolus organizer regions (NORs) of Arabidopsis thaliana. The method involves CHEF gel electrophoresis of agarose-embedded DNA following restriction endonuclease digestion to cut the NORs into large but resolvable segments, followed by digestion with methylation-sensitive restriction endonucleases and conventional (or CHEF) gel electrophoresis, in a second dimension. Resulting products are then detected by Southern blotting or PCR analyses capable of discriminating rRNA gene subtypes. PMID:27576719

  7. Conducting Polymer Electrodes for Gel Electrophoresis

    OpenAIRE

    Bengtsson, Katarina; Nilsson, Sara; Robinson, Nathaniel D

    2014-01-01

    In nearly all cases, electrophoresis in gels is driven via the electrolysis of water at the electrodes, where the process consumes water and produces electrochemical by-products. We have previously demonstrated that p-conjugated polymers such as poly(3,4-ethylenedioxythiophene) (PEDOT) can be placed between traditional metal electrodes and an electrolyte to mitigate electrolysis in liquid (capillary electroosmosis/electrophoresis) systems. In this report, we extend our previous result to gel ...

  8. Counterbalancing hydrodynamic sample distortion effects increases resolution of free-flow zone electrophoresis.

    Science.gov (United States)

    Weber, G; Bauer, J

    1998-06-01

    On fractionation of highly heterogeneous protein mixtures, optimal resolution was achieved by forcing proteins to migrate through a preestablished pH gradient, until they entered a medium with a pH similar but not equal to their pIs. For this purpose, up to seven different media were pumped through the electrophoresis chamber so that they were flowing adjacently to each other, forming a pH gradient declining stepwise from the cathode to the anode. This gradient had a sufficiently strong band-focusing effect to counterbalance sample distortion effects of the flowing medium as proteins approached their isoelectric medium closer than 0.5 pH units. Continuous free-flow zone electrophoresis (FFZE) with high throughput capability was applicable if proteins did not precipitate or aggregate in these media. If components of heterogeneous protein mixtures had already started to precipitate or aggregate, in a medium with a pH exceeding their pI by more than 0.5 pH units, the application of interval modus and media forming flat pH gradients appeared advantageous.

  9. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; Olthuis, Wouter; van den Berg, Albert

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  10. Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Luttge, R.; Olthuis, W.; Berg, van den A.

    2005-01-01

    The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration

  11. Determination of antibacterial flomoxef in serum by capillary electrophoresis.

    Science.gov (United States)

    Kitahashi, Toshihiro; Furuta, Itaru

    2003-04-01

    A determination method of flomoxef (FMOX) concentration in serum by capillary electrophoresis is developed. Serum samples are extracted with acetonitrile. After pretreatment, they are separated in a fused-silica capillary tube with a 25 mM borate buffer (pH 10.0) as a running buffer that contains 50mM sodium dodecyl sulfate. The FMOX and acetaminophen (internal standard) are detected by UV absorbance at 200 nm. Linearity (0-200 mg/L) is good, and the minimum limit of detection is 1.0 mg/L (S/N = 3). The relative standard deviations of intra- and interassay variability are 1.60-4.78% and 2.10-3.31%, respectively, and the recovery rate is 84-98%. This method can be used for determination of FMOX concentration in serum.

  12. Separation of ions in acidic solution by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Thornton, Michelle [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Capillary electrophoresis (CE) is an effective method for separating ionic species according to differences in their electrophoretic mobilities. CE separations of amino acids by direct detection are difficult due to their similar electrophoretic mobilities and low absorbances. However, native amino acids can be separated by CE as cations at a low pH by adding an alkanesulfonic acid to the electrolyte carrier which imparts selectivity to the system. Derivatization is unnecessary when direct UV detection is used at 185 nm. Simultaneous speciation of metal cations such as vanadium (IV) and vanadium (V) can easily be performed without complexation prior to analysis. An indirect UV detection scheme for acidic conditions was also developed using guanidine as the background carrier electrolyte (BCE) for the indirect detection of metal cations. Three chapters have been removed for separate processing. This report contains introductory material, references, and general conclusions. 80 refs.

  13. Stacking and discontinuous buffers in capillary zone electrophoresis.

    Science.gov (United States)

    Shihabi, Z K

    2000-08-01

    Discontinuous buffers for capillary zone electrophoresis (CZE) can be used under less rigid conditions compared to those for isotachophoresis for stacking. They can be prepared simply by modifying the sample itself, either by addition of small inorganic ions, low conductivity diluents, or both, and also by adjusting its pH, meanwhile injecting a large volume on the capillary. Zwitterionic and organic-based buffers such as triethanolamine and tris(hydroxymethyl)aminomethane (Tris) are well suited for stacking due to their low conductivity, provided the buffer is discontinuous as demonstrated here. A simple mechanism based on discontinuous buffers is described to explain many of the observed stacking types in CZE, pointing out the many similarities to transient isotachophoresis.

  14. Simultaneous determination of five flavonoids in saussurea involucrata by capillary electrophoresis

    International Nuclear Information System (INIS)

    Li, Y.; Zhong, H.; Zhong, H.

    2013-01-01

    A method of determination of five flavonoids in Saussurea involucrata by beta-cyclodextrin modified capillary zone electrophoresis has been developed.The effects of buffer pH and buffer concentration, applied voltage and beta-CD concentrations on the separation were systematically investigated. The optimum condition providing baseline separation of all compounds within 8 min was obtained in the 20 mmol per liter borax buffer (pH 9.2), 20 kV applied voltage and 8 mmol per liter beta-CD. The linearity, detection limits, limits of quantification, reproducibility and recovery were satisfactory. The beta-cyclodextrin modified capillary zone electrophoresis method proposed here has been satisfactorily employed to analyze S. involucrate samples. (author)

  15. Characterization of Seed Storage Proteins from Chickpea Using 2D Electrophoresis Coupled with Mass Spectrometry

    OpenAIRE

    Singh, Pramod Kumar; Shrivastava, Nidhi; Chaturvedi, Krishna; Sharma, Bechan; Bhagyawant, Sameer S.

    2016-01-01

    Proteomic analysis was employed to map the seed storage protein network in landrace and cultivated chickpea accessions. Protein extracts were separated by two-dimensional gel electrophoresis (2D-GE) across a broad range 3.0–10.0 immobilized pH gradient (IPG) strips. Comparative elucidation of differentially expressed proteins between two diverse geographically originated chickpea accessions was carried out using 2D-GE coupled with mass spectrometry. A total of 600 protein spots were detected ...

  16. Capillaries modified by noncovalent anionic polymer adsorption for capillary zone electrophoresis, micellar electrokinetic capillary chromatography and capillary electrophoresis mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L; Hansen, S H; Gammelgaard, Bente

    2001-01-01

    A simple coating procedure for generation of a high and pH-independent electroosmotic flow in capillary zone electrophoresis (CZE) and micellar electrokinetic capillary chromatography (MEKC) is described. The bilayer coating was formed by noncovalent adsorption of the ionic polymers Polybrene...... capillaries was (4.9+/-0.1) x 10(-4) cm2V(-1)s(-1) in a pH-range of 2-10 (ionic strength = 30 mM). When alkaline compounds were used as test substances intracapillary and intercapillary migration time variations (n = 6) were less than 1% relative standard deviation (RSD) and 2% RSD, respectively in the entire...... pH range. The coating was fairly stable in the presence of sodium dodecyl sulfate, and this made it possible to perform fast MEKC separations at low pH. When neutral compounds were used as test substances, the intracapillary migration time variations (n = 6) were less than 2% RSD in a pH range of 2...

  17. Two-dimensional capillary electrophoresis: capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection

    Science.gov (United States)

    Dickerson, Jane A.; Ramsay, Lauren M.; Dada, Oluwatosin O.; Cermak, Nathan

    2011-01-01

    Capillary isoelectric focusing and capillary zone electrophoresis are coupled with laser-induced fluorescence detection to create an ultrasensitive two-dimensional separation method for proteins. In this method, two capillaries are joined through a buffer filled interface. Separate power supplies control the potential at the injection end of the first capillary and at the interface; the detector is held at ground potential. Proteins are labeled with the fluorogenic reagent Chromeo P503, which preserves the isoelectric point of the labeled protein. The labeled proteins were mixed with ampholytes and injected into the first dimension capillary. A focusing step was performed with the injection end of the capillary at high pH and the interface at low pH. To mobilize components, the interface was filled with a high pH buffer, which was compatible with the second dimension separation. A fraction was transferred to the second dimension capillary for separation. The process of fraction transfer and second dimension separation was repeated two dozen times. The separation produced a spot capacity of 125. PMID:20603830

  18. Padrão Nictemeral do pH Ruminal e Comportamento Alimentar de Cabras Leiteiras Alimentadas com Dietas Contendo Diferentes Relações Volumoso: Concentrado Nictemeral Pattern of Ruminal pH and Feeding Behavior of Dairy Goats Fed Diets with Different Roughage to Concentrate Ratio

    Directory of Open Access Journals (Sweden)

    André Luigi Gonçalves

    2001-12-01

    Full Text Available Os objetivos do presente estudo foram a caracterização do padrão nictemeral do pH ruminal e a avaliação do comportamento alimentar de cabras leiteiras alimentadas com dietas compostas por diferentes relações volumoso:concentrado. Foram utilizadas cinco cabras, com peso médio de 58 kg, não-lactantes, não-gestantes, fistuladas no rúmen, em cinco períodos experimentais. Cada animal foi observado em cada um dos cinco tratamentos, que consistiram das relações volumoso:concentrado de 100:0, 80:20, 60:40, 40:60 e 20:80, em um delineamento em quadrado latino 5×5. As dietas foram fornecidas a cada 6 horas, buscando amenizar a variação dos níveis de pH ruminal, durante o período de 24 horas, para todos os tratamentos. Após a adaptação dos animais às dietas experimentais, estes foram observados por um período de 48 horas, no qual foi mensurado o pH ruminal a cada hora, bem como em outro período de mesma duração, em que se observou o comportamento a cada 10 minutos. Foi constatado que o nível de concentrado crescente resultou em decréscimo sobre o pH, cujos valores decresceram mais drasticamente em níveis acima de 60%. Observou-se também o efeito de tratamento sobre tempo de alimentação, ruminação e ócio. O tempo de alimentação foi maior para as dietas contendo valores acima de 60% de volumoso. A dieta contendo 100% de volumoso apresentou maior tempo de ruminação e menor ócio, seguida das dietas contendo 80 e 60% de volumoso, enquanto aquelas contendo 40 e 20% apresentaram menor tempo de ruminação e maior ócio.The objectives of the present study were to characterize nictemeral pattern of ruminal pH and feed behavior of dairy goats fed diets presenting different ratios of roughage:concentrate. Five non pregnant non lactating goats, ruminally cannulated, and averaging 58 kg were used during the five experimental periods. A 5x5 Latin square was used to evaluate five treatments consisted of roughage to concentrate

  19. Preparative electrophoresis of industrial fission product solutions

    International Nuclear Information System (INIS)

    Tret, Joel

    1971-07-01

    The aim of this work is to contribute to the development of the continuous electrophoresis technique while studying its application in the preparative electrophoresis of industrial fission product solutions. The apparatus described is original. It was built for the purposes of the investigation and proved very reliable in operation. The experimental conditions necessary to maintain and supervise the apparatus in a state of equilibrium are examined in detail; their stability is an important factor, indispensable to the correct performance of an experiment. By subjecting an industrial solution of fission products to preparative electrophoresis it is possible, according to the experimental conditions, to prepare carrier-free radioelements of radiochemical purity (from 5 to 7 radioelements): 137 Cs, 90 Sr, 141+144 Ce, 91 Y, 95 Nb, 95 Zr, 103+106 Ru. (author) [fr

  20. Ultraviolet-absorbing organic anions in uremic serum separated by capillary zone electrophoresis, and quantification of hippuric acid

    NARCIS (Netherlands)

    Schoots, A.C.; Verheggen, T.P.E.M.; Vries, de P.M.J.M.; Everaerts, F.M.

    1990-01-01

    Organic anions accumulated in blood serum of patients with chronic renal failure were separated by a novel technique: closed-system capillary zone electrophoresis (CZE) in a pH6 carrier-electrolyte system. Hippuric acid (HA), p-hydroxyhippuric acid, and uric acid were identified by their co-elution

  1. Explorative data analysis of two-dimensional electrophoresis gels

    DEFF Research Database (Denmark)

    Schultz, J.; Gottlieb, D.M.; Petersen, Marianne Kjerstine

    2004-01-01

    of gels is presented. First, an approach is demonstrated in which no prior knowledge of the separated proteins is used. Alignment of the gels followed by a simple transformation of data makes it possible to analyze the gels in an automated explorative manner by principal component analysis, to determine......Methods for classification of two-dimensional (2-DE) electrophoresis gels based on multivariate data analysis are demonstrated. Two-dimensional gels of ten wheat varieties are analyzed and it is demonstrated how to classify the wheat varieties in two qualities and a method for initial screening...... if the gels should be further analyzed. A more detailed approach is done by analyzing spot volume lists by principal components analysis and partial least square regression. The use of spot volume data offers a mean to investigate the spot pattern and link the classified protein patterns to distinct spots...

  2. Undergraduate physics laboratory: Electrophoresis in chromatography paper

    Science.gov (United States)

    Hyde, Alexander; Batishchev, Oleg

    2015-12-01

    An experiment studying the physical principles of electrophoresis in liquids was developed for an undergraduate laboratory. We have improved upon the standard agarose gel electrophoresis experimental regime with a straightforward and cost-effective procedure, in which drops of widely available black food coloring were separated by electric field into their dye components on strips of chromatography paper soaked in a baking soda/water solution. Terminal velocities of seven student-safe dyes were measured as a function of the electric potential applied along the strips. The molecular mobility was introduced and calculated by analyzing data for a single dye. Sources of systematic and random errors were investigated.

  3. Studies of transferin polymorphism in Swedish cattle using agarose gel electrophoresis

    International Nuclear Information System (INIS)

    Liberg, P.; Carlstroem, G.

    1976-01-01

    The polymorphic transferrin picture in the sera from 894 Swedish cattle was investigated with an agarose gel electrophoresis technique. The serum transferrin bands in the electrophoresis pattern were first identified by labelling with 59 Fe. Six existing phenotypes based on the alleles Tf(supA), Tf(supD) and Tf(supE) could be detected. The frequencies of transferrin types and transferrin alleles are presented, and it is concluded that there are great differences in the frequencis between the Swedish Red and White and the Swedish Friesian. (author)

  4. Development in electrophoresis: instrumentation for two-dimensional gel electrophoresis of protein separation and application of capillary electrophoresis in micro-bioanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Aoshuang [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    This dissertation begins with a general introduction of topics related to this work. The following chapters contain three scientific manuscripts, each presented in a separate chapter with accompanying tables, figures, and literature citations. The final chapter summarizes the work and provides some prospective on this work. This introduction starts with a brief treatment of the basic principles of electrophoresis separation, followed by a discussion of gel electrophoresis and particularly polyacrylamide gel electrophoresis for protein separation, a summary of common capillary electrophoresis separation modes, and a brief treatment of micro-bioanalysis application of capillary electrophoresis, and ends with an overview of protein conformation and dynamics.

  5. Lodenafil carbonate tablets: optimization and validation of a capillary zone electrophoresis method

    OpenAIRE

    Codevilla, Cristiane F; Ferreira, Pâmela Cristina L; Sangoi, Maximiliano S; Fröehlich, Pedro Eduardo; Bergold, Ana Maria

    2012-01-01

    A simple capillary zone electrophoresis (CZE) method was developed and validated for the analysis of lodenafil carbonate in tablets. Response surface methodology was used for optimization of the pH and concentration of the buffer, applied voltage and temperature. The method employed 50 mmol L-1 borate buffer at pH 10 as background electrolyte with an applied voltage of 15 kV. The separation was carried out in a fused-silica capillary maintained at 32.5 ºC and the detection wavelength was 214 ...

  6. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS ...

    African Journals Online (AJOL)

    Four strains of eri, Samia cynthia ricini Lepidoptera: Saturniidae that can be identified morphologically and maintained at North East Institute of Science and Technology, Jorhat were characterized based on their protein profile by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and DNA by random ...

  7. Contemporary sample stacking in analytical electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Šlampová, Andrea; Malá, Zdeňka; Pantůčková, Pavla; Gebauer, Petr; Boček, Petr

    2013-01-01

    Roč. 34, č. 1 (2013), s. 3-18 ISSN 0173-0835 R&D Projects: GA ČR GAP206/10/1219 Institutional support: RVO:68081715 Keywords : biological samples * stacking * trace analysis * zone electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.161, year: 2013

  8. DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.

    Energy Technology Data Exchange (ETDEWEB)

    SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.

    2004-03-24

    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNA populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.

  9. Contemporary sample stacking in analytical electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Malá, Zdeňka; Šlampová, Andrea; Křivánková, Ludmila; Gebauer, Petr; Boček, Petr

    2015-01-01

    Roč. 36, č. 1 (2015), s. 15-35 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA13-05762S Institutional support: RVO:68081715 Keywords : biological samples * stacking * trace analysis * zone electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.482, year: 2015

  10. Matching Two-dimensional Gel Electrophoresis' Spots

    DEFF Research Database (Denmark)

    Dos Anjos, António; AL-Tam, Faroq; Shahbazkia, Hamid Reza

    2012-01-01

    This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches. This ar...

  11. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida

    2014-01-01

    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  12. Concentration polarization in nanochannel DNA electrophoresis

    NARCIS (Netherlands)

    Dubsky, P.; Das, Siddhartha; van den Berg, Albert; Eijkel, Jan C.T.

    2011-01-01

    We demonstrate that the large field electrophoresis of a single DNA molecule in nanofluidic systems is accompanied by concentration polarization. We illustrate this phenomena by utilizing our electrophoretic simulation tool SIMUL. First we in-vestigate a simple system with univalent strong

  13. Distribution of hemoglobinopathies in patients presenting for electrophoresis and comparison of result with High performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    R Jha

    2015-09-01

    Full Text Available Background: Nearly 226 million carriers of thalassemias and abnormal hemoglobin are present worldwide according to the World Health Organization (WHO. The laboratory plays an important role in the investigation of the thalassemias and hemoglobinopathies. Cellulose acetate electrophoresis at alkaline pH and diagnosis based mainly on visual impression of thickness of band may miss the thalassemic trait patients. The aim of this study was to find out different hemoglobinopathies and thalassemia presenting in our hospital and to compare electrophoresis results with HPLC.Materials and Methods: This study was performed in the hematopathology section of Department of Pathology of Tribhuvan University Teaching Hospital on cases sent for electrophoresis during 18 months period from October 2013 to March 2015 and included hemoglobinopathies and thalassemias identified by either electrophoresis or HPLC. 97 cases fulfilled the inclusion criteria and thus were included in the study. Electrophoresis at alkaline pH was done in all whereas HPLC was performed in 27 cases.Results: A sharp peak of hemoglobinopathies and thalassemias was seen in Tharu community though other communities are also affected. Thalassemia trait was the most common diagnosis (26.8% followed by sickle cell anemia (21.6%.  Electrophoresis was efficient in detecting some alpha thalassemia variants but missed many cases of beta thalassemia trait.Conclusion: Beta Thalassemia trait and sickle cell anemia both are common in Nepal , along with some other hemoglobinopathies  A sharp peak of hemoglobinopathies and thalassemias are seen in Tharu community. These abnormal hemoglobins and thalassemias are mainly seen in Terai region. Electrophoresis fails to quantify hemoglobin percentage and thus is not appropriate test in beta thalassemia screening. 

  14. Sample Stacking in capillary zone electrophoresis : Principles, advantages and limitations

    NARCIS (Netherlands)

    Beckers, J.L.; Bocek, P.

    2000-01-01

    The principles of stacking procedures are described and their properties are discussed, including the fundamentals of the behavior of zone boundaries and the consequences of the self-correcting properties of boundaries in moving boundary electrophoresis, isotachophoresis, and zone electrophoresis.

  15. Nonradioactive telomerase activity assay by microchip electrophoresis: privileges to the classical gel electrophoresis assay.

    Science.gov (United States)

    Zhelev, Zhivko; Bakalova, Rumiana; Ewis, Ashraf; Ohba, Hideki; Ishikawa, Mitsuru; Baba, Yoshinobu

    2005-08-01

    The present study accents on the privileges of microchip-based electrophoresis to the conventional gel electrophoresis in separation of telomerase repeat amplification protocol/polymerase chain reaction (PCR) ladder products obtained in telomerase-catalyzed reaction in cancer cells. We try to clarify the interpretation of the results obtained by both electrophoretic procedures and to avoid misinterpretation as a result of PCR-dependent artefacts.

  16. Standardizing electrophoresis conditions: how to eliminate a major source of error in the comet assay.

    Directory of Open Access Journals (Sweden)

    Gunnar Brunborg

    2015-06-01

    Full Text Available In the alkaline comet assay, cells are embedded in agarose, lysed, and then subjected to further processing including electrophoresis at high pH (>13. We observed very large variations of mean comet tail lengths of cell samples from the same population when spread on a glass or plastic substrate and subjected to electrophoresis. These variations might be cancelled out if comets are scored randomly over a large surface, or if all the comets are scored. The mean tail length may then be representative of the population, although its standard error is large. However, the scoring process often involves selection of 50 – 100 comets in areas selected in an unsystematic way from a large gel on a glass slide. When using our 96-sample minigel format (1, neighbouring sample variations are easily detected. We have used this system to study the cause of the comet assay variations during electrophoresis and we have defined experimental conditions which reduce the variations to a minimum. We studied the importance of various physical parameters during electrophoresis: (i voltage; (ii duration of electrophoresis; (iii electric current; (iv temperature; and (v agarose concentration. We observed that the voltage (V/cm varied substantially during electrophoresis, even within a few millimetres of distance between gel samples. Not unexpectedly, both the potential ( V/cm and the time were linearly related to the mean comet tail, whereas the current was not. By measuring the local voltage with microelectrodes a few millimetres apart, we observed substantial local variations in V/cm, and they increased with time. This explains the large variations in neighbouring sample comet tails of 25% or more. By introducing simple technology (circulation of the solution during electrophoresis, and temperature control, these variations in mean comet tail were largely abolished, as were the V/cm variations. Circulation was shown to be particularly important and optimal conditions

  17. Diamond cubic phase of monoolein and water as an amphiphilic matrix for electrophoresis of oligonucleotides.

    Science.gov (United States)

    Carlsson, Nils; Winge, Ann-Sofie; Engström, Sven; Akerman, Björn

    2005-10-06

    We used a cubic liquid crystal formed by the nonionic monoglyceride monoolein and water as a porous matrix for the electrophoresis of oligonucleotides. The diamond cubic phase is thermodynamically stable when in contact with a water-rich phase, which we exploit to run the electrophoresis in the useful submarine mode. Oligonucleotides are separated according to size and secondary structure by migration through the space-filling aqueous nanometer pores of the regular liquid crystal, but the comparatively slow migration means the cubic phase will not be a replacement for the conventional DNA gels. However, our demonstration that the cubic phase can be used in submarine electrophoresis opens up the possibility for a new matrix for electrophoresis of amphiphilic molecules. From this perspective, the results on the oligonucleotides show that water-soluble particles of nanometer size, typical for the hydrophilic parts of membrane-bound proteins, may be a useful separation motif. A charged contamination in the commercial sample of monoolein, most likely oleic acid that arises from its hydrolysis, restricts useful buffer conditions to a pH below 5.6.

  18. 21 CFR 862.2485 - Electrophoresis apparatus for clinical use.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrophoresis apparatus for clinical use. 862.2485 Section 862.2485 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Instruments § 862.2485 Electrophoresis apparatus for clinical use. (a) Identification. An electrophoresis...

  19. A chip-type thin-layer electrochemical cell coupled with capillary electrophoresis for online separation of electrode reaction products

    Energy Technology Data Exchange (ETDEWEB)

    He, Jian-Bo, E-mail: jbhe@hfut.edu.cn; Cui, Ting; Zhang, Wen-Wen; Deng, Ning

    2013-07-05

    Graphical abstract: -- Highlights: •A new coupling of thin-layer electrolysis with capillary electrophoresis (CE). •Rapid electrolysis, direct sampling followed by online CE separation. •At least 13 products of quercetin oxidation were separated. •Thermodynamic and kinetic parameters were determined from CE peak areas. -- Abstract: A coupling technique of thin-layer electrolysis with high-performance capillary electrophoresis/UV–vis technique(EC/HPCE/UV–vis) is developed for online separation and determination of electrode reaction products. A chip-type thin-layer electrolytic (CTE) cell was designed and fabricated, which contains a capillary channel and a background electrolyte reservoir, allowing rapid electrolysis, direct sampling and online electrophoretic separation. This chip-type setup was characterized based on an electrophoresis expression of Nernst equation that was applied to the redox equilibrium of o-tolidine at different potentials. The utility of the method was demonstrated by separating and determining the electro-oxidation products of quercetin in different pH media. Two main products were always found in the studied time, potential and pH ranges. The variety of products increased not only with increasing potential but also with increasing pH value, and in total, at least 13 products were observed in the electropherograms. This work illustrates a novel example of capillary electrophoresis used online with thin-layer electrolysis to separate and detect electrode reaction products.

  20. A chip-type thin-layer electrochemical cell coupled with capillary electrophoresis for online separation of electrode reaction products

    International Nuclear Information System (INIS)

    He, Jian-Bo; Cui, Ting; Zhang, Wen-Wen; Deng, Ning

    2013-01-01

    Graphical abstract: -- Highlights: •A new coupling of thin-layer electrolysis with capillary electrophoresis (CE). •Rapid electrolysis, direct sampling followed by online CE separation. •At least 13 products of quercetin oxidation were separated. •Thermodynamic and kinetic parameters were determined from CE peak areas. -- Abstract: A coupling technique of thin-layer electrolysis with high-performance capillary electrophoresis/UV–vis technique(EC/HPCE/UV–vis) is developed for online separation and determination of electrode reaction products. A chip-type thin-layer electrolytic (CTE) cell was designed and fabricated, which contains a capillary channel and a background electrolyte reservoir, allowing rapid electrolysis, direct sampling and online electrophoretic separation. This chip-type setup was characterized based on an electrophoresis expression of Nernst equation that was applied to the redox equilibrium of o-tolidine at different potentials. The utility of the method was demonstrated by separating and determining the electro-oxidation products of quercetin in different pH media. Two main products were always found in the studied time, potential and pH ranges. The variety of products increased not only with increasing potential but also with increasing pH value, and in total, at least 13 products were observed in the electropherograms. This work illustrates a novel example of capillary electrophoresis used online with thin-layer electrolysis to separate and detect electrode reaction products

  1. Ph3CCOOSnPh3.Ph3PO AND Ph3CCOOSnPh3.Ph3AsO: SYNTHESIS AND INFRARED STUDY

    Directory of Open Access Journals (Sweden)

    ABDOU MBAYE

    2014-08-01

    Full Text Available The mixture of ethanolic solutions of Ph3CCOOSnPh3 and Ph3PO or Ph3AsO gives Ph3CCOOSnPh3.Ph3PO and Ph3CCOOSnPh3.Ph3AsO adducts which have been characterized by infrared spectroscopy. A discrete structure is suggested for both, the environment around the tin centre being trigonal bipyramidal, the triphenylacetate anion behaving as a mondentate ligand.

  2. Microfluidic chip-capillary electrophoresis devices

    CERN Document Server

    Fung, Ying Sing; Du, Fuying; Guo, Wenpeng; Ma, Tongmei; Nie, Zhou; Sun, Hui; Wu, Ruige; Zhao, Wenfeng

    2015-01-01

    Capillary electrophoresis (CE) and microfluidic chip (MC) devices are relatively mature technologies, but this book demonstrates how they can be integrated into a single, revolutionary device that can provide on-site analysis of samples when laboratory services are unavailable. By introducing the combination of CE and MC technology, Microfluidic Chip-Capillary Electrophoresis Devices broadens the scope of chemical analysis, particularly in the biomedical, food, and environmental sciences. The book gives an overview of the development of MC and CE technology as well as technology that now allows for the fabrication of MC-CE devices. It describes the operating principles that make integration possible and illustrates some achievements already made by the application of MC-CE devices in hospitals, clinics, food safety, and environmental research. The authors envision further applications for private and public use once the proof-of-concept stage has been passed and obstacles to increased commercialization are ad...

  3. Detection of telomerase activity using microchip electrophoresis.

    Science.gov (United States)

    Karasawa, Koji; Arakawa, Hidetoshi

    2015-07-01

    Telomerase participates in malignant transformation or immortalization of cells and thus has attracted attention as an anticancer drug target and diagnostic tumor marker. The telomeric repeat amplification protocol (TRAP) and improved TRAP methods (TRAP-fluorescence, TRAP-hybridization, etc.) are widely used forms of this telomerase assay. However, these approaches generally employ acrylamide gel electrophoresis after amplification of telomeric repeats by polymerase chain reaction (PCR), making these TRAP methods time consuming and technically demanding. In this study we developed a novel telomerase assay using microchip electrophoresis for rapid and highly sensitive detection of telomerase activity in cancer cells. The mixed gel of 0.8% hydroxypropyl methylcellulose (HPMC) and 0.3% polyethylene oxide (PEO) with SYBR Gold (fluorescent reagent) was used for microchip electrophoresis. As a result, the product amplified by a telomerase-positive cell could be measured in one cell per assay and detected with high reproducibility (CV=0.67%) in the short time of 100s. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Determination of molecular weight of silk fibroin by non-gel sieving capillary electrophoresis.

    Science.gov (United States)

    Wei, Wei; Zhang, Yaopeng; Shao, Huili; Hu, Xuechao

    2010-01-01

    A simple non-gel sieving capillary electrophoresis (NGSCE) method was established to determine the MW of silk fibroin using CE. The background electrolyte with a pH of 8.8 was based on three components: polyethylene glycol, tris(hydroxymethyl)aminomethane, and sodium dodecyl sulfate (SDS). NGSCE showed a good linear relationship with satisfactory reproducibility between the migration time and the MW of standard proteins. It was found that the regenerated silk fibroin had an MW around 83 kDa with a wide MW distribution (MWD). This absolute value is lower than the result obtained from SDS-polyacrylamide gel electrophoresis due to the different principles of the methods, but their similar MWD shapes indicated that NGSCE could be a feasible, highly sensitive, rapid method for determination of the MW of silk fibroin.

  5. Determination of underivatized amino acids to evaluate quality of beer by capillary electrophoresis with online sweeping technique.

    Science.gov (United States)

    Luo, Tian; Ke, Jing; Xie, Yunfei; Dong, Yuming

    2017-10-01

    Capillary electrophoresis (CE) with ultraviolet detection was applied to determine underivatized amino acids in beer, based on the coordination interaction of copper ions and amino acids. An online sweeping technique was combined with CE to improve detection sensitivity. Using the United Nations Food Agriculture Organization/World Health Organization model of essential amino acid pattern and flavor of amino acids, the quality and taste in three kinds of beer were evaluated. It was found that Beer2 had higher quality than the other two kinds and the content of phenylalanine, proline, serine, and isoleucine was relatively large in all three kinds of beers with a great influence on beer flavor. Optimal conditions for separation were as follows: 50mM CuSO 4 at pH 4.40 as buffer; total length of fused silica capillary, 73 cm; effective length, 65 cm; separation voltage, 22.5 kV; and optimized sweeping condition, 70 seconds. In the appropriate range, linearity (r 2  > 0.9989), precision with a relative standard deviation amino acids in beer and to perform quantitative analysis directly without derivatization for the first time. Copyright © 2017. Published by Elsevier B.V.

  6. Titanium Dioxide Photocatalytic Polymerization of Acrylamide for Gel Electrophoresis (TIPPAGE) of Proteins and Structural Identification by Mass Spectrometry

    Science.gov (United States)

    Zhang, Wenyang; Yuan, Zhiwei; Huang, Lulu; Kang, Jie; Jiang, Ruowei; Zhong, Hongying

    2016-01-01

    Polyacrylamide gel electrophoresis (PAGE) coupled with mass spectrometry has been well established for separating, identifying and quantifying protein mixtures from cell lines, tissues or other biological samples. The copolymerization process of acrylamide and bis-acrylamide is the key to mastering this powerful technique. In general, this is a vinyl addition reaction initiated by free radical-generating reagents such as ammonium persulfate (APS) and tetramethylethylenediamine (TEMED) under basic pH and degassing experimental condition. We report herein a photocatalytic polymerization approach that is based on photo-generated hydroxyl radicals with nanoparticles of titanium dioxide. It was shown that the polymerization process is greatly accelerated in acidic condition when ultraviolet light shots on the gel solution containing TiO2 nanoparticles without degassing. This feature makes it very useful in preparing Triton X-100 acid urea (TAU) gel that has been developed for separating basic proteins such as histones and variants in acidic experimental condition. Additionally, the presence of titanium dioxide in the gel not only improves mechanistic property of gels but also changes the migration pattern of different proteins that have different affinities to titanium dioxide. PMID:26865351

  7. Genetic heterogeneity of Campylobacter concisus determined by pulsed field gel electrophoresis-based macrorestriction profiling

    DEFF Research Database (Denmark)

    Matsheka, M.I.; Elisha, B.G.; Lastovica, A.L.

    2002-01-01

    1 for pulsed field gel electrophoresis-based genotyping. Subsequently, 53 strains of C concisus, principally from cases of diarrhoea in children, were examined. Fifty-one distinct patterns were obtained, indicating the high discriminatory potential of the method. Patterns comprised between one...... comprised of several genomospecies. The pulsed field gel electrophoresis typing method described here has considerable potential for molecular epidemiological studies of C concisus and may be a useful adjunctive method for helping to resolve key taxonomic issues for this species....... and 14 restriction fragments, with type and reference strains of two well-defined genomospecies of oral and faecal origin containing six and 12 fragments respectively. Our results show that C concisus is genetically diverse and suggest the species as currently defined to be a taxonomic continuum...

  8. Research Article. The Influence of Some Parameters on Chiral Separation of Ibuprofen by High-Performance Liquid Chromatography and Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Balint Alina

    2017-03-01

    Full Text Available Objective: The aim of the study was to compare the influence of mobile phase composition and temperature on chiral separation of racemic ibuprofen by capillary electrophoresis and high performance liquid chromatography with UV detection. Materials and methods: Racemic ibuprofen was analysed on a chiral OVM column with an HPLC system 1100 Agilent Technologies, under isocratic elution, by using potassium dihydrogen phosphate 20 mM and ethanol in mobile phase. The flow rate was set at 1 mL/min, UV detector at 220 nm and different column temperatures were tested. For electrophoresis separation an Agilent CE G1600AX Capillary Electrophoresis System system, with UV detection, was used. The electrophoresis analysis was performed at different pH values and temperatures, with phosphate buffer 25 mM and methyl-β-cyclodextrin as chiral selector. Results: The chromatograhic analysis reveals a high influence of mobile phase pH on ibuprofen enantiomers separation. An elution with a mixture of potassium dihydrogen phosphate 20 mM pH=3 and ethanol, at 25°C, allowed enantiomers separation with good resolution in less than 8 min. Conclusions: The proposed HPLC method proved suitable for the separation of ibuprofen enantiomers with a good resolution, but the capillary electrophoresis tested parameters did not allow chiral discrimination.

  9. Colloid molecular weight estimation by gel chromatography/acrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Liberatore, F.A.; Dearborn, C.; Nigam, S.; Poon, C.; Camin, L.; Liteplo, M.

    1984-01-01

    Size or molecular weight (MW) estimation of radiolabeled collides in aqueous solutions has long been a problem. The authors have prepared several minimicroaggregated albumin colloids (mμAA) by heat denaturation of stannous-containing HSA solutions at pH 7.0, 7.5, and 8.5). The resulting colloids were labeled with Tc-99m and compared with Au-198 colloid and Tc-99m-antimony sulfide colloid (Tc-99m-Sb/sub 2/S3) by gel chromatography and gel electrophoresis. Tc-99mm-mμAA aggregated at pH 7.0 and the Au-198 colloid appeared in the external void volume of a BioRad A5.0 agarose column indicating an apparent MW of > 5 x 10/sup 6/ daltons. The pH7.5 Tc-99m-mμAA, migrated within the filtration range of the column as did a small fraction of Tc-99m-Sb/sub 2/S/sub 3/, suggesting that the MW is between 6 x 10/sup 4/ - 5 x 10/sup 6/ daltons. The Tc-99m-mμAA, aggregated at pH 8.5, had an apparent MW on gel filtration similar to that of untreated albumin, MW 6.6 x 10-/sup 4/ daltons. The mobilities of the colloids, on acrylamide disc gel electrophoresis, were consistent with the results on gel chromatography. The largest colloids, Au-198 colloid and pH 7.0 Tc-99m-mμAA, barely entered the separating gel; intermediate sized colloids, a small fraction of Tc-99m-Sb/sub 2/S/sub 3/ and pH 7.5 Tc-99m-mμAA migrated farther into the separating gel; while pH 8.5 Tc-99m-mμAA had mobility approaching that of untreated albumin. Lymphoscintigraphy studies using these colloids in animals showed the predicted, particle size-related differences in migration and clearance. The authors conclude that gel chromatography and gel electrophoresis are useful methods for estimating the apparent size of the colloidal particles

  10. Automatic DNA Diagnosis for 1D Gel Electrophoresis Images using Bio-image Processing Technique.

    Science.gov (United States)

    Intarapanich, Apichart; Kaewkamnerd, Saowaluck; Shaw, Philip J; Ukosakit, Kittipat; Tragoonrung, Somvong; Tongsima, Sissades

    2015-01-01

    DNA gel electrophoresis is a molecular biology technique for separating different sizes of DNA fragments. Applications of DNA gel electrophoresis include DNA fingerprinting (genetic diagnosis), size estimation of DNA, and DNA separation for Southern blotting. Accurate interpretation of DNA banding patterns from electrophoretic images can be laborious and error prone when a large number of bands are interrogated manually. Although many bio-imaging techniques have been proposed, none of them can fully automate the typing of DNA owing to the complexities of migration patterns typically obtained. We developed an image-processing tool that automatically calls genotypes from DNA gel electrophoresis images. The image processing workflow comprises three main steps: 1) lane segmentation, 2) extraction of DNA bands and 3) band genotyping classification. The tool was originally intended to facilitate large-scale genotyping analysis of sugarcane cultivars. We tested the proposed tool on 10 gel images (433 cultivars) obtained from polyacrylamide gel electrophoresis (PAGE) of PCR amplicons for detecting intron length polymorphisms (ILP) on one locus of the sugarcanes. These gel images demonstrated many challenges in automated lane/band segmentation in image processing including lane distortion, band deformity, high degree of noise in the background, and bands that are very close together (doublets). Using the proposed bio-imaging workflow, lanes and DNA bands contained within are properly segmented, even for adjacent bands with aberrant migration that cannot be separated by conventional techniques. The software, called GELect, automatically performs genotype calling on each lane by comparing with an all-banding reference, which was created by clustering the existing bands into the non-redundant set of reference bands. The automated genotype calling results were verified by independent manual typing by molecular biologists. This work presents an automated genotyping tool from DNA

  11. Automatic DNA Diagnosis for 1D Gel Electrophoresis Images using Bio-image Processing Technique

    Science.gov (United States)

    2015-01-01

    Background DNA gel electrophoresis is a molecular biology technique for separating different sizes of DNA fragments. Applications of DNA gel electrophoresis include DNA fingerprinting (genetic diagnosis), size estimation of DNA, and DNA separation for Southern blotting. Accurate interpretation of DNA banding patterns from electrophoretic images can be laborious and error prone when a large number of bands are interrogated manually. Although many bio-imaging techniques have been proposed, none of them can fully automate the typing of DNA owing to the complexities of migration patterns typically obtained. Results We developed an image-processing tool that automatically calls genotypes from DNA gel electrophoresis images. The image processing workflow comprises three main steps: 1) lane segmentation, 2) extraction of DNA bands and 3) band genotyping classification. The tool was originally intended to facilitate large-scale genotyping analysis of sugarcane cultivars. We tested the proposed tool on 10 gel images (433 cultivars) obtained from polyacrylamide gel electrophoresis (PAGE) of PCR amplicons for detecting intron length polymorphisms (ILP) on one locus of the sugarcanes. These gel images demonstrated many challenges in automated lane/band segmentation in image processing including lane distortion, band deformity, high degree of noise in the background, and bands that are very close together (doublets). Using the proposed bio-imaging workflow, lanes and DNA bands contained within are properly segmented, even for adjacent bands with aberrant migration that cannot be separated by conventional techniques. The software, called GELect, automatically performs genotype calling on each lane by comparing with an all-banding reference, which was created by clustering the existing bands into the non-redundant set of reference bands. The automated genotype calling results were verified by independent manual typing by molecular biologists. Conclusions This work presents an

  12. Multiplexed Western Blotting Using Microchip Electrophoresis.

    Science.gov (United States)

    Jin, Shi; Furtaw, Michael D; Chen, Huaxian; Lamb, Don T; Ferguson, Stephen A; Arvin, Natalie E; Dawod, Mohamed; Kennedy, Robert T

    2016-07-05

    Western blotting is a commonly used protein assay that combines the selectivity of electrophoretic separation and immunoassay. The technique is limited by long time, manual operation with mediocre reproducibility, and large sample consumption, typically 10-20 μg per assay. Western blots are also usually used to measure only one protein per assay with an additional housekeeping protein for normalization. Measurement of multiple proteins is possible; however, it requires stripping membranes of antibody and then reprobing with a second antibody. Miniaturized alternatives to Western blot based on microfluidic or capillary electrophoresis have been developed that enable higher-throughput, automation, and greater mass sensitivity. In one approach, proteins are separated by electrophoresis on a microchip that is dragged along a polyvinylidene fluoride membrane so that as proteins exit the chip they are captured on the membrane for immunoassay. In this work, we improve this method to allow multiplexed protein detection. Multiple injections made from the same sample can be deposited in separate tracks so that each is probed with a different antibody. To further enhance multiplexing capability, the electrophoresis channel dimensions were optimized for resolution while keeping separation and blotting times to less than 8 min. Using a 15 μm deep × 50 μm wide × 8.6 cm long channel, it is possible to achieve baseline resolution of proteins that differ by 5% in molecular weight, e.g., ERK1 (44 kDa) from ERK2 (42 kDa). This resolution allows similar proteins detected by cross-reactive antibodies in a single track. We demonstrate detection of 11 proteins from 9 injections from a single Jurkat cell lysate sample consisting of 400 ng of total protein using this procedure. Thus, multiplexed Western blots are possible without cumbersome stripping and reprobing steps.

  13. The fluid mechanics of continuous flow electrophoresis

    Science.gov (United States)

    Saville, D. A.

    1990-01-01

    The overall objective is to establish theoretically and confirm experimentally the ultimate capabilities of continuous flow electrophoresis chambers operating in an environment essentially free of particle sedimentation and buoyancy. The efforts are devoted to: (1) studying the effects of particle concentration on sample conductivity and dielectric constant. The dielectric constant and conductivity were identified as playing crucial roles in the behavior of the sample and on the resolving power and throughput of continuous flow devices; and (2) improving the extant mathematical models to predict flow fields and particle trajectories in continuous flow electrophoresis. A dielectric spectrometer was designed and built to measure the complex dielectric constant of a colloidal dispersion as a function of frequency between 500 Hz and 200 kHz. The real part of the signal can be related to the sample's conductivity and the imaginary part to its dielectric constant. Measurements of the dielectric constants of several different dispersions disclosed that the dielectric constants of dilute systems of the sort encountered in particle electrophoresis are much larger than would be expected based on the extant theory. Experiments were carried out to show that, in many cases, this behavior is due to the presence of a filamentary structure of small hairs on the particle surface. A technique for producing electrokinetically ideal synthetic latex particles by heat treating was developed. Given the ubiquitous nature of hairy surfaces with both cells and synthetic particles, it was deemed necessary to develop a theory to explain their behavior. A theory for electrophoretic mobility of hairy particles was developed. Finally, the extant computer programs for predicting the structure of electro-osmotically driven flows were extended to encompass flow channels with variable wall mobilities.

  14. Pulsed field gel electrophoresis a practical guide

    CERN Document Server

    Birren, Bruce

    1993-01-01

    Pulsed Field Gel Electrophoresis: A Practical Guide is the first laboratory manual to describe the theory and practice of this technique. Based on the authors' experience developing pulsed field gel instruments and teaching procedures, this book provides everything a researcher or student needs to know in order to understand and carry out pulsed field gel experiments. Clear, well-tested protocols assume only that users have a basic familiarity with molecular biology. Thorough coverage of useful data, theory, and applications ensures that this book is also a lasting resource for more adv

  15. Fast high-throughput method for the determination of acidity constants by capillary electrophoresis: I. Monoprotic weak acids and bases.

    Science.gov (United States)

    Fuguet, Elisabet; Ràfols, Clara; Bosch, Elisabeth; Rosés, Martí

    2009-04-24

    A new and fast method to determine acidity constants of monoprotic weak acids and bases by capillary zone electrophoresis based on the use of an internal standard (compound of similar nature and acidity constant as the analyte) has been developed. This method requires only two electrophoretic runs for the determination of an acidity constant: a first one at a pH where both analyte and internal standard are totally ionized, and a second one at another pH where both are partially ionized. Furthermore, the method is not pH dependent, so an accurate measure of the pH of the buffer solutions is not needed. The acidity constants of several phenols and amines have been measured using internal standards of known pK(a), obtaining a mean deviation of 0.05 pH units compared to the literature values.

  16. Determination of dioxopromethazine hydrochloride by capillary electrophoresis with electrochemiluminescence detection

    International Nuclear Information System (INIS)

    Li Yunhui; Wang Chunyan; Sun Jinying; Zhou Yongchang; You Tianyan; Wang Erkang; Fung Yingsing

    2005-01-01

    The paper presents a rapid method for the determination of dioxopromethazine hydrochloride (DPZ), an antihistamine drug, by the capillary electrophoresis with electrochemiluminescene detection (CE-ECL) using tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy) 3 2+ ) reagent. This CE-ECL detection method has high sensitivity, good selectivity and reproducibility for DPZ analysis. Under the optimized conditions: separation capillary, 38 cm length (25 μm i.d.); sample injection, 10 s at 8 kV; separation voltage, 12.5 kV; running buffer, 20 mmol L -1 sodium phosphate of pH 6.0; detection potential, 1.15 V; 50 mmol L -1 of phosphate buffer (pH 7.14) containing 5 mmol L -1 of Ru(bpy) 3 2+ in ECL detection cell, the detection limit of DPZ was 0.05 μmol L -1 (S/N = 3). The linear range extended from 5 to 100 μmol L -1 . The linear curve obtained was Y = 181.62 + 9.28X with a correlation coefficient of 0.9970. The relative standard deviations of the ECL intensity and the migration time for six continuous injections of 5 μmol L -1 DPZ were 3.7% and 0.92%, respectively. The CE-ECL method was applied to analyze DPZ in real samples including tablets, rat serum and human urine, and satisfactory results were obtained without interference from samples matrix. The CE-ECL technique was proved to be a potential method for the detection of DPZ in clinic analysis

  17. Microchip Immunoaffinity Electrophoresis of Antibody-Thymidine Kinase 1 Complex

    Science.gov (United States)

    Pagaduan, Jayson V.; Ramsden, Madison; O’Neill, Kim; Woolley, Adam T.

    2015-01-01

    Thymidine kinase-1 (TK1) is an important cancer biomarker whose serum levels are elevated in early cancer development. We developed a microchip electrophoresis immunoaffinity assay to measure recombinant purified TK1 (pTK1) using an antibody that binds to human TK1. We fabricated poly(methyl methacrylate) microfluidic devices to test the feasibility of detecting antibody (Ab)-pTK1 immune complexes as a step towards TK1 analysis in clinical serum samples. We were able to separate immune complexes from unbound antibodies using 0.5X phosphate buffer saline (pH 7.4) containing 0.01% Tween-20, with 1% w/v methylcellulose that acts as a dynamic surface coating and sieving matrix. Separation of the antibody and Ab-pTK1 complex was observed within a 5 mm effective separation length. This method of detecting pTK1 is easy to perform, requires only a 10 μL sample volume, and takes just 1 minute for separation. PMID:25486911

  18. Electrohydrodynamic properties of succinoglycan as probed by fluorescence correlation spectroscopy, potentiometric titration and capillary electrophoresis.

    Science.gov (United States)

    Duval, Jérôme F L; Slaveykova, Vera I; Hosse, Monika; Buffle, Jacques; Wilkinson, Kevin J

    2006-10-01

    The electrostatic, hydrodynamic and conformational properties of aqueous solutions of succinoglycan have been analyzed by fluorescence correlation spectroscopy (FCS), proton titration, and capillary electrophoresis (CE) over a large range of pH values and electrolyte (NaCl) concentrations. Using the theoretical formalism developed previously for the electrokinetic properties of soft, permeable particles, a quantitative analysis for the electro-hydrodynamics of succinoglycan is performed by taking into account, in a self-consistent manner, the measured values of the diffusion coefficients, electric charge densities, and electrophoretic mobilities. For that purpose, two limiting conformations for the polysaccharide in solution are tested, i.e. succinoglycan behaves as (i) a spherical, random coil polymer or (ii) a rodlike particle with charged lateral chains. The results show that satisfactory modeling of the titration data for ionic strengths larger than 50 mM can be accomplished using both geometries over the entire range of pH values. Electrophoretic mobilities measured for sufficiently large pH values (pH > 5-6) are in line with predictions based on either model. The best manner to discriminate between these two conceptual models is briefly discussed. For low pH values (pH < 5), both models indicate aggregation, resulting in an increase of the hydrodynamic permeability and a decrease of the diffusion coefficient.

  19. Enhanced resolution of DNA restriction fragments: A procedure by two-dimensional electrophoresis and double-labeling

    International Nuclear Information System (INIS)

    Yi, M.; Au, L.C.; Ichikawa, N.; Ts'o, P.O.

    1990-01-01

    A probe-free method was developed to detect DNA rearrangement in bacteria based on the electrophoretic separation of twice-digested restriction fragments of genomic DNA into a two-dimensional (2-D) pattern. The first restriction enzyme digestion was done in solution, followed by electrophoresis of the restriction fragments in one dimension. A second restriction enzyme digestion was carried out in situ in the gel, followed by electrophoresis in a second dimension perpendicular to the first electrophoresis. The 2-D pattern provides for the resolution of 300-400 spots, which are defined and indexed by an x,y coordinate system with size markers. This approach has greatly increased the resolution power over conventional one-dimensional (1-D) electrophoresis. To study DNA rearrangement, a 2-D pattern from a test strain was compared with the 2-D pattern from a reference strain. After the first digestion, genomic DNA fragments from the test strain were labeled with 35S, while those from the reference strain were labeled with 32P. This was done to utilize the difference in the energy emission of 35S and 32P isotopes for autoradiography when two x-ray films were exposed simultaneously on top of the gel after the 2-D electrophoresis. The irradiation from the decay of 35S exposed only the lower film, whereas the irradiation from the decay of 32P exposed both the lower and upper films. Different DNA fragments existed in the test DNA compared with the reference DNA can be identified unambiguously by the differential two 2-D patterns produced on two films upon exposure to the 35S and 32P fragments in the same gel. An appropriate photographic procedure further simplified the process, allowing only the difference in DNA fragments between these two patterns to be shown in the map

  20. Separation of 2-aminobenzoic acid-derivatized glycosaminoglycans and asparagine-linked glycans by capillary electrophoresis.

    Science.gov (United States)

    Sato, Kae; Sato, Kiichi; Okubo, Akira; Yamazaki, Sunao

    2005-01-01

    A capillary electrophoresis method was developed for the analysis of oligosaccharides combined with derivatization with 2-aminobenzoic acid. Glycosaminoglycan delta-disaccharides were effectively resolved on a fused-silica capillary tube using 150 mM borate, pH 8.5, as a running electrolyte solution. This analytical method was applied to the identification of glycosaminoglycan in combination with enzymatic digestion. The separation of N-glycans or glucose-oligomers was performed with a phosphate buffer containing polyethylene glycol or borate as an electrolyte solution. This method is expected to be useful in the determination of oligosaccharide structures in a glycoprotein.

  1. Micro-injector for capillary electrophoresis.

    Science.gov (United States)

    Sáiz, Jorge; Koenka, Israel Joel; García-Ruiz, Carmen; Müller, Beat; Chwalek, Thomas; Hauser, Peter C

    2015-08-01

    A novel micro-injector for capillary electrophoresis for the handling of samples with volumes down to as little as 300 nL was designed and built in our laboratory for analyses in which the available volume is a limitation. The sample is placed into a small cavity located directly in front of the separation capillary, and the injection is then carried out automatically by controlled pressurization of the chamber with compressed air. The system also allows automated flushing of the injection chamber as well as of the capillary. In a trial with a capillary electrophoresis system with contactless conductivity detector, employing a capillary of 25 μm diameter, the results showed good stability of migration times and peak areas. To illustrate the technique, the fast separation of five inorganic cations (Na(+) , K(+) , NH4 (+) , Ca(2+) , and Mg(2+) ) was set up. This could be achieved in less than 3 min, with good limits of detection (10 μM) and linear ranges (between about 10 and 1000 μM). The system was demonstrated for the determination of the inorganic cations in porewater samples of a lake sediment core. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Electrophoresis in the analysis of natural and industrial ob ects

    International Nuclear Information System (INIS)

    Stepanov, A.V.; Korchemnaya, E.K.

    1979-01-01

    Given is a brief review on practical application of electrophoresis in the analysis of natural and industrial objects. Suggested are expressiVe methods of thorium, uranium and rare earth elements separation in minerals by electrophoresis. The possibility of quantitative determination of rare earth elements in meteorites by the method of electromigration is shown. By means of electrophoresis identified are forms of radioruthenium in a sea water. Shown is the electrophoresis application for reactor loop water analysis, for environment contamination study, for determination of some rare earth yield in reactions of uranium fission by heavy ions

  3. Simultaneous determination of anthraquinones, their 8-beta-D-glucosides, and sennosides of Rhei Rhizoma by capillary electrophoresis.

    Science.gov (United States)

    Koyama, Junko; Morita, Izumi; Fujiyoshi, Hirotaka; Kobayashi, Norihiro

    2005-05-01

    The simultaneous separation and determination of major anthraquinones (emodin, chrysophanol, rhein and their glucosides, aloe-emodin, sennoside A, and sennoside B) of Rhei Rhizoma were achieved by cyclodextrin modified capillary zone electrophoresis. The running electrolyte used in this method was 0.005 M alpha-cyclodextrin in 0.03 M borate buffer (pH 10.0) containing 20% acetonitrile, with an applied voltage of 20 kV.

  4. Mapping of Chlamydia trachomatis proteins by immobiline-polyacrylamide two-dimensional electrophoresis: spot identification by N-terminal sequencing and immunoblotting

    DEFF Research Database (Denmark)

    Bini, L; Sanchez-Campillo, M; Santucci, A

    1996-01-01

    Proteins from purified elementary bodies of Chlamydia trachomatis were separated by two-dimensional gel electrophoresis on nonlinear wide-range immobilized pH gradients in the first dimension and polyacrylamide gradient gels in the second dimension. The maps obtained with this system are highly...

  5. Effects of interferon gamma on Chlamydia trachomatis serovar A and L2 protein expression investigated by two-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Shaw, A; Christiansen, Gunna; Birkelund, Svend

    1999-01-01

    ]methionine and two-dimensional gel electrophoresis with immobilized pH gradients in order to investigate changes in the protein expression of C. trachomatis serovar A and L2 caused by treatment with IFN-gamma. In contrast to what was observed in C. trachomatis L2, our results showed that, in C. trachomatis A, down...

  6. Determination of acid dissociation constants of warfarin and hydroxywarfarins by capillary electrophoresis.

    Science.gov (United States)

    Nowak, Paweł; Olechowska, Paulina; Mitoraj, Mariusz; Woźniakiewicz, Michał; Kościelniak, Paweł

    2015-08-10

    In this work the acid dissociation constants--pKa of warfarin and its all important oxidative metabolites have been determined by capillary electrophoresis-based methods. It has resulted in a complete description of two acid-base dissociation equilibria, yet not investigated experimentally for phase I metabolites of warfarin. The capillary electrophoresis (CE) method based on the relation between effective electrophoretic mobilities and pH has proven to be a suitable tool for pKa determination, while the spectrophotometric (CE-DAD) and the internal standard methods (IS-CE), have appeared to be promising alternative approaches. The CE-DAD approach based on the change in absorbance spectra between the acidic and basic forms is a combination between capillary electrophoresis and spectrophotometric titration, and yields very consistent values of pKa1 with CE. The IS-CE, in turn, enables an estimation of pKa1 and pKa2 from only two analytical runs, however, less accurate than CE and CE-DAD. The Debye-Hückel model has been confirmed experimentally as a good predictor of pKa values at various ionic strengths. Therefore, it has been used in determination of thermodynamic pKa1 and pKa2, referring to the zero ionic strength. The results are important from the analytical, pharmacological, and theoretical points of view. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Optimized sample preparation for two-dimensional gel electrophoresis of soluble proteins from chicken bursa of Fabricius

    Directory of Open Access Journals (Sweden)

    Zheng Xiaojuan

    2009-10-01

    Full Text Available Abstract Background Two-dimensional gel electrophoresis (2-DE is a powerful method to study protein expression and function in living organisms and diseases. This technique, however, has not been applied to avian bursa of Fabricius (BF, a central immune organ. Here, optimized 2-DE sample preparation methodologies were constructed for the chicken BF tissue. Using the optimized protocol, we performed further 2-DE analysis on a soluble protein extract from the BF of chickens infected with virulent avibirnavirus. To demonstrate the quality of the extracted proteins, several differentially expressed protein spots selected were cut from 2-DE gels and identified by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS. Results An extraction buffer containing 7 M urea, 2 M thiourea, 2% (w/v 3-[(3-cholamidopropyl-dimethylammonio]-1-propanesulfonate (CHAPS, 50 mM dithiothreitol (DTT, 0.2% Bio-Lyte 3/10, 1 mM phenylmethylsulfonyl fluoride (PMSF, 20 U/ml Deoxyribonuclease I (DNase I, and 0.25 mg/ml Ribonuclease A (RNase A, combined with sonication and vortex, yielded the best 2-DE data. Relative to non-frozen immobilized pH gradient (IPG strips, frozen IPG strips did not result in significant changes in the 2-DE patterns after isoelectric focusing (IEF. When the optimized protocol was used to analyze the spleen and thymus, as well as avibirnavirus-infected bursa, high quality 2-DE protein expression profiles were obtained. 2-DE maps of BF of chickens infected with virulent avibirnavirus were visibly different and many differentially expressed proteins were found. Conclusion These results showed that method C, in concert extraction buffer IV, was the most favorable for preparing samples for IEF and subsequent protein separation and yielded the best quality 2-DE patterns. The optimized protocol is a useful sample preparation method for comparative proteomics analysis of chicken BF tissues.

  8. Analysis of the surface membrane of iodinated leukemic cells by SDS-polyacrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Ishitani, Kunihiko; Ikeda, Akira; Tamura, Minoru; Takeuchi, Hidekazu; Ihara, Koji

    1980-01-01

    Surface proteins of human leukemic cells were labeled selectively by lactoperoxydase catalysed-iodination and examined by SDS-polyacrylamide gel electrophoresis. The electrophoretic pattern of the surface membranes of cells from a patients with chronic mylogeneous leukemia in blast crisis was of B cell type and showed Ia like antigen. Leukemic cells from a patient with hairly cell leukemia also expressed the pattern of B cell type when tested by this method the technique of iodinating cell surface with lactoperoxidase is useful in characterization of leukemia cells for diagnosis and monitoring of clinical course. (author)

  9. Optimization of a pulsed-field gel electrophoresis for molecular typing of Proteus mirabilis

    Directory of Open Access Journals (Sweden)

    Alper Karagöz

    2013-09-01

    Full Text Available Objective: For the detection of outbreaks caused byProteus mirabilis, strains clonal relations are determinedmethods as “pulsed-field gel electrophoresis (PFGE”.The aim of this study was optimization of a pulsed-fieldgel electrophoresis for molecular typing of P. mirabilis.Methods: In this study, PFGE’ protocol is optimized foruse in molecular typing of P. mirabilis. Phylogenetic analyzesof strains were evaluated with Bionumerics softwaresystem (version 6.01; Applied Maths, Sint-Martens-Latem, Belgium.Results: This protocol compared with Gram-negativebacteria PFGE protocols, NotI enzyme is suitable for thisbacterium. Electrophoresis conditions should be revealedas; - block 1: initial pulse duration 1 sec, ending pulseduration 30 sec, striking angle 120°, the current 6 V/cm2,temperature 14°C, time 8 hours; - block 2: initial pulseduration 30 sec, ending pulse duration 70 sec, strikingangle 120°, the current 6 V/cm2, temperature 14°C, time16 hours; - TBE, pH=8.4.Conclusion: P. mirabilis strains were typed by PFGE andBionumerics analysis program were determined clonal relationships.The procedure was simple, reproducible andsuitable for these bacteria. Also it was evaluated, becauseof reducing time, the solution volumes and enzymes canbe economically. Outbreaks of nosocomial infections dueto bacteria studied assessment and the potential to provideuseful information about the degree of prevalence.This optimized protocol is allowed different centers’ PFGEresults to compare with other laboratories results. J ClinExp Invest 2013; 4 (3: 306-312Key words: Proteus mirabilis, molecular typing, pulsedfieldgel electrophoresis.

  10. Muscle protein analysis. II. Two-dimensional electrophoresis of normal and diseased human skeletal muscle

    Energy Technology Data Exchange (ETDEWEB)

    Giometti, C.S. (Argonne National Lab., IL); Barany, M.; Danon, M.J.; Anderson, N.G.

    1980-07-01

    High-resolution two-dimensional electrophoresis was used to analyze the major proteins of normal and pathological human-muscle samples. The normal human-muscle pattern contains four myosin light chains: three that co-migrate with the myosin light chains from rabbit fast muscle (extensor digitorum longus), and one that co-migrates with the light chain 2 from rabbit slow muscle (soleus). Of seven Duchenne muscular dystrophy samples, four yielded patterns with decreased amounts of actin and myosin relative to normal muscle, while three samples gave patterns comparable to that for normal muscle. Six samples from patients with myotonic dystrophy also gave normal patterns. In nemaline rod myopathy, in contrast, the pattern was deficient in two of the fast-type myosin light chains.

  11. Automated DNA electrophoresis, hybridization and detection

    International Nuclear Information System (INIS)

    Zapolski, E.J.; Gersten, D.M.; Golab, T.J.; Ledley, R.S.

    1986-01-01

    A fully automated, computer controlled system for nucleic acid hybridization analysis has been devised and constructed. In practice, DNA is digested with restriction endonuclease enzyme(s) and loaded into the system by pipette; 32 P-labelled nucleic acid probe(s) is loaded into the nine hybridization chambers. Instructions for all the steps in the automated process are specified by answering questions that appear on the computer screen at the start of the experiment. Subsequent steps are performed automatically. The system performs horizontal electrophoresis in agarose gel, fixed the fragments to a solid phase matrix, denatures, neutralizes, prehybridizes, hybridizes, washes, dries and detects the radioactivity according to the specifications given by the operator. The results, printed out at the end, give the positions on the matrix to which radioactivity remains hybridized following stringent washing

  12. Recent applications of nanomaterials in capillary electrophoresis.

    Science.gov (United States)

    González-Curbelo, Miguel Ángel; Varela-Martínez, Diana Angélica; Socas-Rodríguez, Bárbara; Hernández-Borges, Javier

    2017-10-01

    Nanomaterials have found an important place in Analytical Chemistry and, in particular, in Separation Science. Among them, metal-organic frameworks, magnetic and non-magnetic nanoparticles, carbon nanotubes and graphene, as well as their combinations, are the most important nanomaterials that have been used up to now. Concerning capillary electromigration techniques, these nanomaterials have also been used as both pseudostationary phases in electrokinetic chromatography (EKC) and as stationary phases in microchip capillary electrophoresis (CE) and capillary electrochromatography (CEC), as a result of their interesting and particular properties. This review article pretends to provide a general and critical revision of the most recent applications of nanomaterials in this field (period 2010-2017). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Electrophoresis in nanochannels: brief review and speculation

    Directory of Open Access Journals (Sweden)

    Santiago Juan G

    2006-11-01

    Full Text Available Abstract The relevant physical phenomena that dominate electrophoretic transport of ions and macromolecules within long, thin nanochannels are reviewed, and a few papers relevant to the discussion are cited. Sample ion transport through nanochannels is largely a function of their interaction with electric double layer. For small ions, this coupling includes the net effect of the external applied field, the internal field of the double layer, and the non-uniform velocity of the liquid. Adsorption/desorption kinetics and the effects of surface roughness may also be important in nanochannel electrophoresis. For macromolecules, the resulting motion is more complex as there is further coupling via steric interactions and perhaps polarization effects. These complex interactions and coupled physics represent a valuable opportunity for novel electrophoretic and chromatographic separations.

  14. Study of Streptavidin-Modified Quantum Dots by Capillary Electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Stanisavljevic, M.; Janů, L.; Šmerková, K.; Křížková, S.; Pizúrová, Naděžda; Ryvolová, M.; Adam, V.; Hubálek, J.; Kizek, R.

    2013-01-01

    Roč. 76, 7-8 (2013), s. 335-343 ISSN 0009-5893 Institutional support: RVO:68081723 Keywords : Capillary electrophoresis * Gel electrophoresis * Avidin-biotin technology * Oligonucleotide * Nanoparticle * quantum dots Subject RIV: CE - Biochemistry Impact factor: 1.370, year: 2013

  15. Inexpensive and Safe DNA Gel Electrophoresis Using Household Materials

    Science.gov (United States)

    Ens, S.; Olson, A. B.; Dudley, C.; Ross, N. D., III; Siddiqi, A. A.; Umoh, K. M.; Schneegurt, M. A.

    2012-01-01

    Gel electrophoresis is the single most important molecular biology technique and it is central to life sciences research, but it is often too expensive for the secondary science classroom or homeschoolers. A simple safe low-cost procedure is described here that uses household materials to construct and run DNA gel electrophoresis. Plastic…

  16. Gel Electrophoresis on a Budget to Dye for

    Science.gov (United States)

    Yu, Julie H.

    2010-01-01

    Gel electrophoresis is one of the most important tools used in molecular biology and has facilitated the entire field of genetic engineering by enabling the separation of nucleic acids and proteins. However, commercial electrophoresis kits can cost up to $800 for each setup, which is cost prohibitive for most classroom budgets. This article…

  17. Influence of pH on the /sup 14/C-labelling pattern after photosynthesis of suspended leaf slices and isolated mesophyll cells from chenopodium album in NaH/sup 14/CO/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, G; Guenther, G [Paedagogische Hochschule Karl Liebknecht, Potsdam (German Democratic Republic). Sektion Chemie/Biologie

    1983-01-01

    Photosynthetic fixation of /sup 14/C from solutions of NaH/sup 14/CO/sub 3/ (at constant concentrations of free CO/sub 2/) by suspended leaf slices or isolated mesophyll cells from Chenopodium album is increased with increasing pH. Above all, the incorporation of radioactivity into amino acids and malate is stimulated. A direct uptake of HCO/sub 3/ ions and its fixation by PEP carboxylase is suggested. Isolated mesophyll cells showed at pH 7.3 a higher rate of photosynthesis than at pH 5.0.

  18. Free-zone electrophoresis of animal cells. 1: Experiments on cell-cell interactions

    Science.gov (United States)

    Todd, P. W.; Hjerten, S.

    1985-01-01

    The electrophoretically migrating zones wasa monitored. The absence of fluid flows in the direction of migration permits direct measurement of electrophoretic velocities of any material. Sedimentation is orthogonal to electrokinetic motion and the effects of particle-particle interaction on electrophoretic mobility is studied by free zone electrophoresis. Fixed erythrocytes at high concentrations, mixtures of fixed erythrocytes from different animal species, and mixtures of cultured human cells were studied in low ionic strength buffers. The electrophoretic velocity of fixed erythrocytes was not altered by increasing cell concentration or by the mixing of erythrocytes from different species. When zones containing cultured human glial cells and neuroblastoma cells are permitted to interact during electrophoresis, altered migration patterns occur. It is found that cell-cell interactions depends upon cell type.

  19. Fractionation of SWNT/nucleic acid complexes by agarose gel electrophoresis

    International Nuclear Information System (INIS)

    Vetcher, Alexandre A; Srinivasan, Srimeenakshi; Vetcher, Ivan A; Abramov, Semen M; Kozlov, Mikhail; Baughman, Ray H; Levene, Stephen D

    2006-01-01

    We show that aqueous dispersions of single-walled carbon nanotubes (SWNTs), prepared with the aid of nucleic acids (NAs) such as RNA or DNA, can be separated into fractions using agarose gel electrophoresis. In a DC electric field, SWNT/NA complexes migrate in the gel in the direction of positive potential to form well-defined bands. Raman spectroscopy as a function of band position shows that nanotubes having different spectroscopic properties possess different electrophoretic mobilities. The migration patterns for SWNT/RNA and SWNT/DNA complexes differ. Parallel elution of the SWNT/NA complexes from the gel during electrophoresis and subsequent characterization by AFM reveals differences in nanotube diameter, length and curvature. The results suggest that fractionation of nanotubes can be achieved by this procedure. We discuss factors affecting the mobility of the nanotube complexes and propose analytical applications of this technique

  20. Fractionation of SWNT/nucleic acid complexes by agarose gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Vetcher, Alexandre A [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Srinivasan, Srimeenakshi [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Vetcher, Ivan A [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Abramov, Semen M [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Kozlov, Mikhail [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Baughman, Ray H [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Levene, Stephen D [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States)

    2006-08-28

    We show that aqueous dispersions of single-walled carbon nanotubes (SWNTs), prepared with the aid of nucleic acids (NAs) such as RNA or DNA, can be separated into fractions using agarose gel electrophoresis. In a DC electric field, SWNT/NA complexes migrate in the gel in the direction of positive potential to form well-defined bands. Raman spectroscopy as a function of band position shows that nanotubes having different spectroscopic properties possess different electrophoretic mobilities. The migration patterns for SWNT/RNA and SWNT/DNA complexes differ. Parallel elution of the SWNT/NA complexes from the gel during electrophoresis and subsequent characterization by AFM reveals differences in nanotube diameter, length and curvature. The results suggest that fractionation of nanotubes can be achieved by this procedure. We discuss factors affecting the mobility of the nanotube complexes and propose analytical applications of this technique.

  1. DNA gel electrophoresis: the reptation model(s).

    Science.gov (United States)

    Slater, Gary W

    2009-06-01

    DNA gel electrophoresis has been the most important experimental tool to separate DNA fragments for several decades. The introduction of PFGE in the 1980s and capillary gel electrophoresis in the 1990s made it possible to study, map and sequence entire genomes. Explaining how very large DNA molecules move in a gel and why PFGE is needed to separate them has been an active field of research ever since the launch of the journal Electrophoresis. This article presents a personal and historical overview of the development of the theory of gel electrophoresis, focusing on the reptation model, the band broadening mechanisms, and finally the factors that limit the read length and the resolution of electrophoresis-based sequencing systems. I conclude with a short discussion of some of the questions that remain unanswered.

  2. Sensitive determination of phenolic acids in extra-virgin olive oil by capillary zone electrophoresis.

    Science.gov (United States)

    Carrasco Pancorbo, Alegría; Cruces-Blanco, Carmen; Segura Carretero, Antonio; Fernández Gutiérrez, Alberto

    2004-11-03

    A sensitive, rapid, efficient, and reliable method for the separation and determination of phenolic acids by capillary zone electrophoresis has been carried out. A detailed method optimization was carried out to separate 14 different compounds by studying parameters such as pH, type and concentration of buffer, applied voltage, and injection time. The separation was performed within 16 min, using a 25 mM sodium borate buffer (pH 9.6) at 25 kV with 8 s of hydrodynamic injection. With this method and using a liquid-liquid extraction system, with recovery values around 95%, it has been possible to detect small quantities of phenolic acids in olive oil samples. This is apparently the first paper showing the quantification of this specific family of phenolic compounds in virgin olive oil samples.

  3. Agarose gel electrophoresis and polyacrylamide gel electrophoresis for visualization of simple sequence repeats.

    Science.gov (United States)

    Anderson, James; Wright, Drew; Meksem, Khalid

    2013-01-01

    In the modern age of genetic research there is a constant search for ways to improve the efficiency of plant selection. The most recent technology that can result in a highly efficient means of selection and still be done at a low cost is through plant selection directed by simple sequence repeats (SSRs or microsatellites). The molecular markers are used to select for certain desirable plant traits without relying on ambiguous phenotypic data. The best way to detect these is the use of gel electrophoresis. Gel electrophoresis is a common technique in laboratory settings which is used to separate deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) by size. Loading DNA and RNA onto gels allows for visualization of the size of fragments through the separation of DNA and RNA fragments. This is achieved through the use of the charge in the particles. As the fragments separate, they form into distinct bands at set sizes. We describe the ability to visualize SSRs on slab gels of agarose and polyacrylamide gel electrophoresis.

  4. Free flow electrophoresis separation and AMS quantitation of 14C-naphthalene-protein adducts

    International Nuclear Information System (INIS)

    Buchholz, Bruce A.; Haack, Kurt W.; Sporty, Jennifer L.; Buckpitt, Alan R.; Morin, Dexter

    2010-01-01

    Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 μCi) of 14 C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with 14 C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.

  5. Free flow electrophoresis separation and AMS quantitation of 14C-naphthalene-protein adducts

    Science.gov (United States)

    Buchholz, Bruce A.; Haack, Kurt W.; Sporty, Jennifer L.; Buckpitt, Alan R.; Morin, Dexter

    2010-04-01

    Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 μCi) of 14C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with 14C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.

  6. Free flow electrophoresis separation and AMS quantitation of {sup 14}C-naphthalene-protein adducts

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Bruce A., E-mail: bbuchholz@llnl.go [Center for AMS, LLNL, 7000 East Avenue, Livermore, CA 94551 (United States); Haack, Kurt W.; Sporty, Jennifer L. [Center for AMS, LLNL, 7000 East Avenue, Livermore, CA 94551 (United States); Buckpitt, Alan R.; Morin, Dexter [Department of Molecular Biosciences, School of Veterinary Medicine, UC Davis, Davis, CA 95616 (United States)

    2010-04-15

    Naphthalene is a volatile aromatic hydrocarbon to which humans are exposed from a variety of sources including mobile air sources and cigarette smoke. Naphthalene produces dose-(concentration)dependent injury to airway epithelial cells of murine lung which is observed at concentrations well below the current occupational exposure standard. Toxicity is dependent upon the cytochrome P450 mediated metabolic activation of the parent substrate to unstable metabolites which become bound covalently to tissue proteins. Nearly 70 proteins have been identified as forming adducts with reactive naphthalene metabolites using in vitro systems but very little work has been conducted in vivo because reasonably large amounts (100 muCi) of {sup 14}C labeled parent compound must be administered to generate detectable adduct levels on storage phosphor screens following separation of labeled proteins by 2D gel electrophoresis. The work described here was done to provide proof of concept that protein separation by free flow electrophoresis followed by AMS detection of protein fractions containing protein bound reactive metabolites would provide adducted protein profiles in animals dosed with trace quantities of labeled naphthalene. Mice were administered 200 mg/kg naphthalene intraperitoneally at a calculated specific activity of 2 DPM/nmol (1 pCi/nmol) and respiratory epithelial tissue was obtained by lysis lavage 4 h post injection. Free flow electrophoresis (FFE) separates proteins in the liquid phase over a large pH range (2.5-11.5) using low molecular weight acids and bases to modify the pH. The apparatus separates fractions into standard 96-well plates that can be used in other protein analysis techniques. The buffers of the fractions have very high carbon content, however, and need to be dialyzed to yield buffers compatible with {sup 14}C-AMS. We describe the processing techniques required to couple FFE to AMS for quantitation of protein adducts.

  7. Conformational intermediate of the amyloidogenic protein beta 2-microglobulin at neutral pH

    DEFF Research Database (Denmark)

    Heegaard, N H; Sen, J W; Kaarsholm, N C

    2001-01-01

    electrophoresis that two conformers spontaneously exist in aqueous buffers at neutral pH. Upon treatment of wild-type beta(2)-microglobulin with acetonitrile or trifluoroethanol, two conformations were also observed. These conformations were in equilibrium dependent on the sample temperature and the percentage...

  8. Quantitative analysis by microchip capillary electrophoresis – current limitations and problem-solving strategies

    NARCIS (Netherlands)

    Revermann, T.; Götz, S.; Künnemeyer, Jens; Karst, U.

    2008-01-01

    Obstacles and possible solutions for the application of microchip capillary electrophoresis in quantitative analysis are described and critically discussed. Differences between the phenomena occurring during conventional capillary electrophoresis and microchip-based capillary electrophoresis are

  9. Development of novel separation techniques for biological samples in capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Huan -Tsung [Iowa State Univ., Ames, IA (United States)

    1994-07-27

    This dissertation includes three different topics: general introduction of capillary electrophoresis (CE); gradient in CE and CE in biological separations; and capillary gel electrophoresis (CGE) for DNA separation. Factors such as temperature, viscosity, pH, and the surface of capillary walls affecting the separation performance are demonstrated. A pH gradient between 3.0 and 5.2 is useful to improve the resolution among eight different organic acids. A flow gradient due to the change in the concentration of surfactant, which is able to coat to the capillary wall to change the flow rate and its direction, is also shown as a good way to improve the resolution for organic compounds. A temperature gradient caused by joule heat is shown by voltage programming to enhance the resolution and shorten the separation time for several phenolic compounds. The author also shows that self-regulating dynamic control of electroosmotic flow in CE by simply running separation in different concentrations of surfactant has less matrix effect on the separation performance. One of the most important demonstrations in this dissertation is that the author proposes on-column reaction which gives several advantages including the use of a small amount of sample, low risk of contamination, and time saving and kinetic features. The author uses this idea with laser induced fluorescence (LIF) as a detection mode to detect an on-column digestion of sub-ng of protein. This technique also is applied to single cell analysis in the group.

  10. Capillary electrophoresis to determine entrapment efficiency of a nanostructured lipid carrier loaded with piroxicam

    Directory of Open Access Journals (Sweden)

    Jessica Otarola

    2015-02-01

    Full Text Available A simple and fast capillary electrophoresis method has been developed to determine the amount of piroxicam loaded in a drug delivery system based on nanostructured lipid carriers (NLCs. The entrapment efficiency of the nanostructured lipid carrier was estimated by measuring the concentration of drug not entrapped in a suspension of NLC. The influence of different parameters on migration times, peak symmetry, efficiency and resolution was studied; these parameters included the pH of the electrophoretic buffer solution and the applied voltage. The piroxicam peak was obtained with a satisfactory resolution. The separation was carried out using a running buffer composed of 50 mM ammonium acetate and 13.75 mM ammonia at pH 9. The optimal voltage was 20 kV and the cartridge temperature was 20 °C. The corresponding calibration curve was linear over the range of 2.7–5.4 µg/mL of NLC suspension. The reproducibility of migration time and peak area were investigated, and the obtained RSD% values (n=5 were 0.99 and 2.13, respectively. Keywords: Capillary electrophoresis, Drug delivery system, Nanostructured lipid carrier, Piroxicam

  11. Separation of sulfated urinary glycosaminoglycans by high-resolution electrophoresis for isotyping of mucopolysaccharidoses in Malaysia.

    Science.gov (United States)

    Nor, Azimah; Zabedah, Md Yunus; Norsiah, Md Desa; Ngu, Lock Hock; Suhaila, Abd Rahman

    2010-06-01

    Mucopolysaccharidoses (MPS) are a group of inherited disorders caused by the deficiency of specific lysosomal enzymes involved in glycosaminoglycans (GAGs) degradation. Currently, there are 11 enzyme deficiencies resulting in seven distinct MPS clinical syndromes and their subtypes. Different MPS syndromes cannot be clearly distinguished clinically due to overlapping signs and symptoms. Measurement of GAGs content in urine and separation of GAGs using high-resolution electrophoresis (HRE) are very useful initial screening tests for isotyping of MPS before specific enzyme diagnostics. In this study, we measured total urinary GAGs by a method using dimethylmethylene blue (DMB), and followed by isolation and separation of GAGs using high resolution electrophoresis (HRE) technique. Of 760 urine samples analyzed, 40 have abnormal GAGs HRE patterns. Thirty-five of these 40 cases have elevated urinary GAGs levels as well. These abnormal HRE patterns could be classified into 4 patterns: Pattern A (elevated DS and HS; suggestive of MPS I, II or VII; 16 cases), Pattern B (elevated HS and CS; suggestive of MPS III; 17 cases), and Pattern C (elevated KS and CS; suggestive of MPS IV, 5 cases), and Pattern D (elevated DS; suggestive of MPS VI; 2 cases). Based on the GAGs HRE pattern and a few discriminating clinical signs, we performed selective enzymatic investigation in 16 cases. In all except one case with MPS VII, the enzymatic diagnosis correlated well with the provisional MPS type as suggested by the abnormal HRE pattern. Our results showed that GAGs HRE is a useful, inexpensive and practical first-line screening test when MPS is suspected clinically, and it provides an important guide to further enzymatic studies on a selective basis.

  12. Photochemical Microscale Electrophoresis Allows Fast Quantification of Biomolecule Binding.

    Science.gov (United States)

    Möller, Friederike M; Kieß, Michael; Braun, Dieter

    2016-04-27

    Intricate spatiotemporal patterns emerge when chemical reactions couple to physical transport. We induce electrophoretic transport by a confined photochemical reaction and use it to infer the binding strength of a second, biomolecular binding reaction under physiological conditions. To this end, we use the photoactive compound 2-nitrobenzaldehyde, which releases a proton upon 375 nm irradiation. The charged photoproducts locally perturb electroneutrality due to differential diffusion, giving rise to an electric potential Φ in the 100 μV range on the micrometer scale. Electrophoresis of biomolecules in this field is counterbalanced by back-diffusion within seconds. The biomolecule concentration is measured by fluorescence and settles proportionally to exp(-μ/D Φ). Typically, binding alters either the diffusion coefficient D or the electrophoretic mobility μ. Hence, the local biomolecule fluorescence directly reflects the binding state. A fit to the law of mass action reveals the dissociation constant of the binding reaction. We apply this approach to quantify the binding of the aptamer TBA15 to its protein target human-α-thrombin and to probe the hybridization of DNA. Dissociation constants in the nanomolar regime were determined and match both results in literature and in control experiments using microscale thermophoresis. As our approach is all-optical, isothermal and requires only nanoliter volumes at nanomolar concentrations, it will allow for the fast screening of biomolecule binding in low volume multiwell formats.

  13. Specific proteins synthesized during the viral lytic cycle in vaccinia virus-infected HeLa cells: analysis by high-resolution, two-dimensional gel electrophoresis

    International Nuclear Information System (INIS)

    Carrasco, L.; Bravo, R.

    1986-01-01

    The proteins synthesized in vaccinia-infected HeLa cells have been analyzed at different times after infection by using two-dimensional gel electrophoresis. Vaccinia-infected cells present up to 198 polypeptides (138 acidic, isoelectric focusing; 60 basic, nonequilibrium pH gradient electrophoresis) not detected in control cells. Cells infected in the presence of cycloheximide show 81 additional polypeptides after cycloheximide removal, resulting in a total estimate of 279 proteins induced after vaccinia infection. The glycoproteins made at various time postinfection were also analyzed. At least 13 proteins labeled with [ 3 H]glucosamine were detected in vaccinia-infected HeLa cells

  14. Changes in the viral distribution pattern after the appearance of the novel influenza A H1N1 (pH1N1) virus in influenza-like illness patients in Peru.

    Science.gov (United States)

    Laguna-Torres, Victor Alberto; Gómez, Jorge; Aguilar, Patricia V; Ampuero, Julia S; Munayco, Cesar; Ocaña, Víctor; Pérez, Juan; Gamero, María E; Arrasco, Juan Carlos; Paz, Irmia; Chávez, Edward; Cruz, Rollin; Chavez, Jaime; Mendocilla, Silvia; Gomez, Elizabeth; Antigoni, Juana; Gonzalez, Sofía; Tejada, Cesar; Chowell, Gerardo; Kochel, Tadeusz J

    2010-07-27

    We describe the temporal variation in viral agents detected in influenza like illness (ILI) patients before and after the appearance of the ongoing pandemic influenza A (H1N1) (pH1N1) in Peru between 4-January and 13-July 2009. At the health centers, one oropharyngeal swab was obtained for viral isolation. From epidemiological week (EW) 1 to 18, at the US Naval Medical Research Center Detachment (NMRCD) in Lima, the specimens were inoculated into four cell lines for virus isolation. In addition, from EW 19 to 28, the specimens were also analyzed by real time-polymerase-chain-reaction (rRT-PCR). We enrolled 2,872 patients: 1,422 cases before the appearance of the pH1N1 virus, and 1,450 during the pandemic. Non-pH1N1 influenza A virus was the predominant viral strain circulating in Peru through (EW) 18, representing 57.8% of the confirmed cases; however, this predominance shifted to pH1N1 (51.5%) from EW 19-28. During this study period, most of pH1N1 cases were diagnosed in the capital city (Lima) followed by other cities including Cusco and Trujillo. In contrast, novel influenza cases were essentially absent in the tropical rain forest (jungle) cities during our study period. The city of Iquitos (Jungle) had the highest number of influenza B cases and only one pH1N1 case. The viral distribution in Peru changed upon the introduction of the pH1N1 virus compared to previous months. Although influenza A viruses continue to be the predominant viral pathogen, the pH1N1 virus predominated over the other influenza A viruses.

  15. Changes in the viral distribution pattern after the appearance of the novel influenza A H1N1 (pH1N1 virus in influenza-like illness patients in Peru.

    Directory of Open Access Journals (Sweden)

    Victor Alberto Laguna-Torres

    Full Text Available BACKGROUND: We describe the temporal variation in viral agents detected in influenza like illness (ILI patients before and after the appearance of the ongoing pandemic influenza A (H1N1 (pH1N1 in Peru between 4-January and 13-July 2009. METHODS: At the health centers, one oropharyngeal swab was obtained for viral isolation. From epidemiological week (EW 1 to 18, at the US Naval Medical Research Center Detachment (NMRCD in Lima, the specimens were inoculated into four cell lines for virus isolation. In addition, from EW 19 to 28, the specimens were also analyzed by real time-polymerase-chain-reaction (rRT-PCR. RESULTS: We enrolled 2,872 patients: 1,422 cases before the appearance of the pH1N1 virus, and 1,450 during the pandemic. Non-pH1N1 influenza A virus was the predominant viral strain circulating in Peru through (EW 18, representing 57.8% of the confirmed cases; however, this predominance shifted to pH1N1 (51.5% from EW 19-28. During this study period, most of pH1N1 cases were diagnosed in the capital city (Lima followed by other cities including Cusco and Trujillo. In contrast, novel influenza cases were essentially absent in the tropical rain forest (jungle cities during our study period. The city of Iquitos (Jungle had the highest number of influenza B cases and only one pH1N1 case. CONCLUSIONS: The viral distribution in Peru changed upon the introduction of the pH1N1 virus compared to previous months. Although influenza A viruses continue to be the predominant viral pathogen, the pH1N1 virus predominated over the other influenza A viruses.

  16. Evaluation of wheat by polyacrylamide gel electrophoresis

    African Journals Online (AJOL)

    PRECIOUS

    2010-01-11

    Jan 11, 2010 ... wheat grains, the low molecular weight (LMW) (10 –70. KDa) and the high ... phoresis has been used to show that large size variation exists between LMW ... extraction buffer (Tris-Hcl 0.05M (pH 8), 0.02% SDS, 30.3% urea,.

  17. Seed protein electrophoresis for identification of fine fibre cotton line in Gossypium hirsutum L

    International Nuclear Information System (INIS)

    Gao Guoqiang; Lv Tiexin; Su Xuehe; Liu Xiaoyong; Wu Defang; Zhu Doubei

    2003-01-01

    Gel electrophoresis was conducted to test seed ethanol resolvable protein in cotton. 13 lines were used, including a fine fibre cotton line (98301) in G. hirsutum L., 4 varieties in G. barbadense L. and 8 varieties in G. hirsutum L.. In results of the 98301 line, Zhongmiansuo 12 and Shiyuan 321, no different protein electro-phoresis band pattern was shown among different seeds belong to the same variety, respectively. In comparison among the 98301 seeds sampled from seven different growth sets in Shandong province, their protein band patterns were the same. On the gel plate, three special bands were distinctive to all the varieties in G. hirsutum L. and other three special bands were distinctive to all the varieties in G. barbadense L.. The three characteristic bands of G. hirsutum L. appeared in the protein band pattern of the 98301 line. It showed that the seed protein composition of the line was inclined to G. hirsutum L. mainly. And, a characteristic band of G. Barbadense L. in the band pattern of the 98301 line proved that the fine fibre cotton line derived from a hybrid between G. barbadense and G. hirsutum L.. The 98301 line was easily distinguished from other varieties in G. hirsutum L. by its distinctive band, i.e. band No.1, and another island cotton band, i.e. band No.10

  18. Ceramic protective coatings applied by sol-gel or electrophoresis

    International Nuclear Information System (INIS)

    Stoch, A.

    1993-01-01

    Sol-gel and electrophoresis are the complementary techniques which may be used for obtaining the ceramic coatings. The composition of such a coatings depends on the composition of electrophoresis bath or sol solution. Thermal treatment is used for densifying the coating and promoting the adherence of coating to the substrate. In presented work silica, silica-alumina or alumina coatings are applied by sol-gel dip coating procedure on steel, aluminium or ceramic substrates. Electrophoresis is employed for obtaining zirconia, alumina or hydroxyapatite coatings on stainless steel. (author). 7 refs

  19. Basic study for gas cleaning using discharge and electrophoresis

    International Nuclear Information System (INIS)

    Su, Zhen-Zhou; Sawada, Jun; Takashima, Kazunori; Katsura, Shinji; Mizuno, Akira

    2004-01-01

    A NO x removal method using discharge plasma and electrophoresis for exhaust control was studied. The 65-50% of NO was oxidized to NO 2 or HNO 3 by the discharge plasma with specific input energy of 45J/l. The electrophoresis was carried out to concentrate the NO 2 or HNO 3 adsorbed on the adsorbents. As a result, 80% of the adsorbed nitrate ions were found in the anode region. A combination of molecular sieve pellets of 13X and glass fiber cloth was tested for the collection of nitrate ions. The ability of simultaneous concentration of nitrate ions and sulfate ions using electrophoresis was examined

  20. Simulating Electrophoresis with Discrete Charge and Drag

    Science.gov (United States)

    Mowitz, Aaron J.; Witten, Thomas A.

    A charged asymmetric rigid cluster of colloidal particles in saline solution can respond in exotic ways to an electric field: it may spin or move transversely. These distinctive motions arise from the drag force of the neutralizing countercharge surrounding the cluster. Because of this drag, calculating the motion of arbitrary asymmetric objects with nonuniform charge is impractical by conventional methods. Here we present a new method of simulating electrophoresis, in which we replace the continuous object and the surrounding countercharge with discrete point-draggers, called Stokeslets. The balance of forces imposes a linear, self-consistent relation among the drag and Coulomb forces on the Stokeslets, which allows us to easily determine the object's motion via matrix inversion. By explicitly enforcing charge+countercharge neutrality, the simulation recovers the distinctive features of electrophoretic motion to few-percent accuracy using as few as 1000 Stokeslets. In particular, for uniformly charged objects, we observe the characteristic Smoluchowski independence of mobility on object size and shape. We then discuss electrophoretic motion of asymmetric objects, where our simulation method is particularly advantageous. This work is supported by a Grant from the US-Israel Binational Science Foundation.

  1. Active airborne contamination control using electrophoresis

    International Nuclear Information System (INIS)

    Veatch, B.D.

    1994-01-01

    In spite of our best efforts, radioactive airborne contamination continues to be a formidable problem at many of the Department of Energy (DOE) weapons complex sites. For workers that must enter areas with high levels of airborne contamination, personnel protective equipment (PPE) can become highly restrictive, greatly diminishing productivity. Rather than require even more restrictive PPE for personnel in some situations, the Rocky Flats Plant (RFP) is actively researching and developing methods to aggressively combat airborne contamination hazards using electrophoretic technology. With appropriate equipment, airborne particulates can be effectively removed and collected for disposal in one simple process. The equipment needed to implement electrophoresis is relatively inexpensive, highly reliable, and very compact. Once airborne contamination levels are reduced, less PPE is required and a significant cost savings may be realized through decreased waste and maximized productivity. Preliminary ''cold,'' or non-radioactive, testing results at the RFP have shown the technology to be effective on a reasonable scale, with several potential benefits and an abundance of applications

  2. Van de Graaff generator for capillary electrophoresis.

    Science.gov (United States)

    Lee, Seung Jae; Castro, Eric R; Guijt, Rosanne M; Tarn, Mark D; Manz, Andreas

    2017-09-29

    A new approach for high voltage capillary electrophoresis (CE) is proposed, which replaces the standard high voltage power supply with a Van de Graaff generator, a low current power source. Because the Van de Graaff generator is a current-limited source (10μA), potentials exceeding 100kV can be generated for CE when the electrical resistance of the capillary is maximized. This was achieved by decreasing the capillary diameter and reducing the buffer ionic strength. Using 2mM borate buffer and a 5μm i.d. capillary, fluorescently labeled amino acids were separated with efficiencies up to 3.5 million plates; a 5.7 fold improvement in separation efficiency compared to a normal power supply (NPS) typically used in CE. This separation efficiency was realized using a simple set-up without significant Joule heating, making the Van de Graaff generator a promising alternative for applying the high potentials required for enhancing resolution in the separation and analysis of highly complex samples, for example mixtures of glycans. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Characterisation of ribosomal proteins from HeLa and Krebs II mouse ascites tumor cells by different two-dimensional polyacrylamide gel electrophoresis techniques

    DEFF Research Database (Denmark)

    Issinger, O G; Beier, H

    1978-01-01

    Electrophoresis of ribosomal proteins according to Kaltschmidt and Wittmann, 1970a, b (pH 8.6/pH 4.5 urea system) yielded 29 proteins for the small subunits and 35 and 37 proteins for the large subunits of Krebs II ascites and HeLa ribosomes, respectively. Analysis of the proteins according...... to a modified technique by Mets and Bogorad (1974) (pH 4.5/pH 8.6 SDS system) revealed 28 and 29 proteins in the small subunits and 37 and 38 proteins in the large subunits of Krebs II ascites and HeLa ribosomes. The molecular weights of the individual proteins were determined by: 1. "three-dimensional" gel...... using the pH 4.5/pH 8.6 SDS system. The molecular weights Krebs II ascites and HeLa ribosomal proteins are compared with those obtained by other authors for different mammalian species....

  4. Interaction of albumins and heparinoids investigated by affinity capillary electrophoresis and free flow electrophoresis.

    Science.gov (United States)

    Mozafari, Mona; El Deeb, Sami; Krull, Friederike; Wildgruber, Robert; Weber, Gerhard; Reiter, Christian G; Wätzig, Hermann

    2018-02-01

    A fast and precise affinity capillary electrophoresis (ACE) method has been applied to investigate the interactions between two serum albumins (HSA and BSA) and heparinoids. Furthermore, different free flow electrophoresis methods were developed to separate the species which appears owing to interaction of albumins with pentosan polysulfate sodium (PPS) under different experimental conditions. For ACE experiments, the normalized mobility ratios (∆R/R f ), which provided information about the binding strength and the overall charge of the protein-ligand complex, were used to evaluate the binding affinities. ACE experiments were performed at two different temperatures (23 and 37°C). Both BSA and HSA interact more strongly with PPS than with unfractionated and low molecular weight heparins. For PPS, the interactions can already be observed at low mg/L concentrations (3 mg/L), and saturation is already obtained at approximately 20 mg/L. Unfractionated heparin showed almost no interactions with BSA at 23°C, but weak interactions at 37°C at higher heparin concentrations. The additional signals also appeared at higher concentrations at 37°C. Nevertheless, in most cases the binding data were similar at both temperatures. Furthermore, HSA showed a characteristic splitting in two peaks especially after interacting with PPS, which is probably attributable to the formation of two species or conformational change of HSA after interacting with PPS. The free flow electrophoresis methods have confirmed and completed the ACE experiments. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Binding of Gallic Acid and Epigallocatechin Gallate to Heat-Unfolded Whey Proteins at Neutral pH Alters Radical Scavenging Activity of in Vitro Protein Digests.

    Science.gov (United States)

    Cao, Yanyun; Xiong, Youling L

    2017-09-27

    Preheated (80 °C for 9 min) whey protein isolate (HWPI) was reacted with 20, 120, and 240 μmol/g (protein basis) gallic acid (GA) or epigallocatechin gallate (EGCG) at neutral pH and 25 °C. Isothermal titration calorimetry and fluorometry showed a similar trend that GA binding to HWPI was moderate but weaker than EGCG binding. However, the shift of maximal fluorescence emission wavelength in opposite directions in response to GA (blue) and EGCG (red) suggests discrepant binding patterns. Electrophoresis results showed that EGCG induced formation of HWPI complexes while GA only had a marginal effect. Both free and phenolic-bound HWPI exhibited mild antiradical activity. However, when subjected to in vitro digestion, synergistic radical-scavenging activity was produced between the phenolics and peptides with the highest synergism being observed on 120 μmol/g phenolics.

  6. Stacking gels: A method for maximising output for pulsed-field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Heng See

    2009-01-01

    Full Text Available Pulsed field gel electrophoresis (PFGE, the gold standard of molecular typing methods, has a major disadvantage of an unusually long electrophoretic time. From the original protocol of 6 days, it was modified to 3 days and subsequently to a single day. We describe the procedure of stacking five to six gels one on top of another in order to increase and maximize the output in a shorter time without compromising the resolution and reproducibility. All the variables that affect pulsed field gels during electrophoresis were taken into consideration. We firstly optimized the parameters to be used and secondly determined whether stacking of five to six gels had any effect on the molecular separation during electrophoresis in comparison with a single gel run. DNA preparation, restriction, electrophoresis, staining and gel documentation was carried out based on previously published methods. Gels were analysed using BioNumerics and dice coefficient and unweighted pair group methods were used to generate dendrograms based on 1.5% tolerance values. Identical band profiles and band resolution-separation were seen in the PFGE patterns with single gel and multiple stacking gels. Cluster analysis further strengthened the fact that results from stacking gels were reproducible and comparable with a single gel run. This method of stacking gels saves time and maximizes the output at the same time. The run time for a single gel was about 28 hours, but with six stacked gels the run time was 54 hours compared with 28 x 6 = 168 hours if they were run separately as single gels thus saving time of 67.86%. Beside the big factor of saving time, stacking gels save resources (electricity, reagents, water, chemicals and working time by increasing the sample throughput in a shorter time without compromising on quality of data. But optimization of working parameters is vital depending on the PFGE system used.

  7. PH og modernismen

    DEFF Research Database (Denmark)

    Ahnfeldt-Mollerup, Merete

    2012-01-01

    Artiklen kaster et kritisk blik på Poul Henningsens samfundsanalyse og dennes sammenhæng med hans design. PH ses i en bredere national og international sammenhæng. Diskussion af designmetoder, æstetik og Bauhaus.......Artiklen kaster et kritisk blik på Poul Henningsens samfundsanalyse og dennes sammenhæng med hans design. PH ses i en bredere national og international sammenhæng. Diskussion af designmetoder, æstetik og Bauhaus....

  8. TECHNIQUES WITH POTENTIAL FOR HANDLING ENVIRONMENTAL SAMPLES IN CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    An assessment of the methods for handling environmental samples prior to capillary electrophoresis (CE) is presented for both aqueous and solid matrices. Sample handling in environmental analyses is the subject of ongoing research at the Environmental Protection Agency's National...

  9. A new electrophoresis technique to separate microsatellite alleles ...

    African Journals Online (AJOL)

    A new electrophoresis technique to separate microsatellite alleles* ... African Journal of Biotechnology ... with the CEQTM 8000 Genetic Analysis System and ABI 3130xl DNA Sequencer easily separated products and determined allelic size, ...

  10. Integration of amperometric sensors for microchip capillary electrophoresis application

    International Nuclear Information System (INIS)

    Dicorato, F; Moore, E; Glennon, J

    2011-01-01

    Capillary electrophoresis is a technique for the separation and analysis of chemical compounds. Techniques adopted from the microchip technology knowledge have led to recent developments of electrophoresis system with integration on microchip. Microchip Capillary Electrophoresis (μCE) systems offer a series of advantages as easy integration for Lab-on-a-chip applications, high performance, portability, speed, minimal solvent and sample requirements. A new technological challenge aims at the development of an economic modular microchip capillary electrophoresis systems using separable and independent units concerning the sensor. In this project we worked on the development of an interchangeable amperometric sensor in order to provide a solution to such electrode passivation and facilitating the use of tailored sensors for specific analyte detection besides. Fluidic chips have been machined from cyclic olefin polymer pallets (Zeonor) using a micro-injection molding machine.

  11. Capillary electrophoresis in the N-glycosylation analysis of biopharmaceuticals

    Czech Academy of Sciences Publication Activity Database

    Guttman, András

    2013-01-01

    Roč. 48, JUL-AUG (2013), s. 132-143 ISSN 0165-9936 Institutional support: RVO:68081715 Keywords : automated workflow * biopharmaceuticals * capillary electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 6.612, year: 2013

  12. Success and failure with phthalate buffers in capillary zone electrophoresis

    NARCIS (Netherlands)

    Bocek, P.; Gebauer, P.; Beckers, J.L.

    2001-01-01

    Phthalate buffers are currently used in capillary electrophoresis as robust electrolyte systems for indirect detection. This contribution demonstrates that these buffers show regularly not only successful regions of mobilities of analytes (sample window) but also regions of failure where the

  13. Characterization of biological macromolecules by electrophoresis and neutron activation

    International Nuclear Information System (INIS)

    Stone, S.F.; Hancock, D.; Zeisler, R.

    1987-01-01

    A procedure combining polyacrylamide gel electrophoresis (PAGE) with INAA and autoradiography was developed to study biological macromolecules and their associated trace elements. Results from the application of this method to several metalloproteins are presented. (author)

  14. Integration of amperometric sensors for microchip capillary electrophoresis application

    Energy Technology Data Exchange (ETDEWEB)

    Dicorato, F; Moore, E [Life Sciences Interface Group, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork (Ireland); Glennon, J, E-mail: eric.moore@tyndall.ie [Chemistry Department, University College Cork, College Road, Cork (Ireland)

    2011-08-17

    Capillary electrophoresis is a technique for the separation and analysis of chemical compounds. Techniques adopted from the microchip technology knowledge have led to recent developments of electrophoresis system with integration on microchip. Microchip Capillary Electrophoresis ({mu}CE) systems offer a series of advantages as easy integration for Lab-on-a-chip applications, high performance, portability, speed, minimal solvent and sample requirements. A new technological challenge aims at the development of an economic modular microchip capillary electrophoresis systems using separable and independent units concerning the sensor. In this project we worked on the development of an interchangeable amperometric sensor in order to provide a solution to such electrode passivation and facilitating the use of tailored sensors for specific analyte detection besides. Fluidic chips have been machined from cyclic olefin polymer pallets (Zeonor) using a micro-injection molding machine.

  15. Methods and instrumentation for quantitative microchip capillary electrophoresis

    NARCIS (Netherlands)

    Revermann, T.

    2007-01-01

    The development of novel instrumentation and analytical methodology for quantitative microchip capillary electrophoresis (MCE) is described in this thesis. Demanding only small quantities of reagents and samples, microfluidic instrumentation is highly advantageous. Fast separations at high voltages

  16. [Study on the method of two dimensional polycrylamide gel electrophoresis on rat condylar chondrocyte].

    Science.gov (United States)

    Wu, Tuo-jiang; Li, Huang; Ma, Qiao-lin; Wang, Wen-mei

    2010-08-01

    To investigate the protein profile by two dimensional polycrylamide gel electrophoresis on the rat condylar chondrocyte in vitro. The third-passage chondrocytes were harvested from the mandibular condyles of 2-day-old rats in this study. The protein profile of the rat mandibular condylar chondrocytes was examined by two dimensional polycrylamide gel electrophoresis (2-DE-PAGE). The 2-DE gel maps on different pH gradients were obtained. The result of modified coomassi blue-sliver staining and sliver staining was compared using Pdquest 7.1 image analysis software. The results showed that the good protein profile of the condylar chondrocytes was obtained by standard Bio-Rad manual. The protein was mainly in the field from pH4 to pH7. The 1203±86 protein points were examined on 2-DE gel map by modified coomassi blue-sliver staining, and 1769±97 protein points was examined by sliver staining. The silver staining map showed more distinctly but higher background than modified coomassi blue-sliver staining. The protein profile of the condylar chondrocytes enriches the proteomic database and gives evidence to further proteomic research. The 2-DE map obtained by modified coomassi blue-sliver staining is more suitable for MALDI-TOF mass identification. Supported by National Natural Science Foundation of China (Grant No. C30700963), China Postdoctoral Science Foundation(Grant No.20090461088), Jiangsu Provincial Postdoctoral Science Foundation (Grant No.0802003C) and Nanjing City's Science and Technology Foundation (Grant No.200905011).

  17. Phylogenetic reconstruction of South American felids defined by protein electrophoresis

    OpenAIRE

    Pecon Slattery, J.; Johnson, W. E.; Goldman, D.; O'Brien, S. J.

    1994-01-01

    Phylogenetic associations among six closely related South American felid species were defined by changes in protein-encoding gene loci. We analyzed proteins isolated from skin fibroblasts using two-dimensional electrophoresis and allozymes extracted from blood cells. Genotypes were determined for multiple individuals of ocelot, margay, tigrina, Geoffroy's cat, kodkod, and pampas cat at 548 loci resolved by two-dimensional electrophoresis and 44 allozyme loci. Phenograms were constructed using...

  18. Field-portable Capillary Electrophoresis Instrument with Conductivity Detection

    International Nuclear Information System (INIS)

    Zhang, H F; Liu, X W; Wang, W; Wang, X L; Tian, L

    2006-01-01

    In this paper a novel capillary electrophoresis chip (CEC) is presented with integrated platinum electrodes and simplified conductivity detector. CEC is fabricated by the method of mechanical modification with probe on organic glass. Capillary electrophoresis chip can rapidly completed ion separation by simulation of concentration distribution and zone-broadening. Detection circuit is simple which can detect pA order current. This system has those advantages such as small volume, low power consumption and linearity, and well suit for field analysis

  19. Capillary Electrophoresis Artifact Due to Eosin

    Science.gov (United States)

    Murphy, Kathleen M.; Berg, Karin D.; Geiger, Tanya; Hafez, Michael; Flickinger, Katie A.; Cooper, Lisa; Pearson, Patrick; Eshleman, James R.

    2005-01-01

    Capillary electrophoresis (CE) is a commonly used tool in the analysis of fluorescently labeled PCR amplification products. We have identified a CE artifact caused by the tissue stain eosin that can complicate the interpretation of CE data. The artifact was detected during routine analysis of a DNA sample isolated from a formalin-fixed, paraffin-embedded tissue sample considered histologically suspicious for a B-cell neoplasm. A standard clinical PCR and CE assay for immunoglobulin heavy chain (IGH) gene rearrangement revealed a weak polyclonal population of rearranged IGH genes and a 71 base peak suspicious for IGH clonality. The spectral properties of the 71 base peak were unusual in that although the dominant fluorescence of the peak was blue, it also fluoresced in green and yellow (blue>green>yellow), raising the suspicion that the peak might represent an artifact. CE analysis of the genomic DNA sample without PCR amplification demonstrated the presence of the 71 base peak, suggesting that the artifact was caused by a contaminant within the DNA sample itself. We demonstrate that eosin, which was used to stain the formalin-fixed tissue during processing, yields a discrete 71 base peak of similar morphology to the contaminant peak on CE analysis. The data suggest that eosin in the fixed tissue was not completely eliminated during nucleic acid extraction, resulting in the artifact peak. We discuss the implications of this potentially common contaminant on the interpretation of CE data and demonstrate that artifacts caused by eosin can be avoided by using more stringent DNA purification steps. Histological dyes may fluoresce, and artifacts from them should be considered when primary peaks contain additional underlying peaks of other colors. PMID:15681487

  20. Capillary electrophoresis: principles and applications in illicit drug analysis.

    Science.gov (United States)

    Tagliaro, F; Turrina, S; Smith, F P

    1996-02-09

    Capillary electrophoresis, which appeared in the early 1980s, is now rapidly expanding into many scientific disciplines, including analytical chemistry, biotechnology and biomedical and pharmaceutical sciences. In capillary electrophoresis,electrokinetic separations are carried out in tiny capillaries at high voltages (10-30 kV), thus obtaining high efficiencies (N > 10(5)) and excellent mass sensitivities (down to 10(-18)-10(-20) moles). The main features of capillary electrophoresis are: versatility of application (from inorganic ions to large DNA fragments), use of different separation modes with different selectivity, extremely low demands on sample volume, negligible running costs, possibility of interfacing with different detection systems, ruggedness and simplicity of instrumentation. Capillary electrophoresis applications in forensic sciences have appeared only recently, but are now rapidly growing, particularly in forensic toxicology. The present paper briefly describes the basic principles of capillary electrophoresis, from both the instrumental and analytical points of view. Furthermore, the main applications in the analysis of illicit/controlled drugs in both illicit preparations and biological samples are presented and discussed (43 references). It is concluded that the particular separation mechanism and the high complementarity of this technique to chromatography makes capillary electrophoresis a new powerful tool of investigation in the hands of forensic toxicologists.

  1. Pulsed-field gel electrophoresis of bacterial chromosomes.

    Science.gov (United States)

    Mawer, Julia S P; Leach, David R F

    2013-01-01

    The separation of fragments of DNA by agarose gel electrophoresis is integral to laboratory life. Nevertheless, standard agarose gel electrophoresis cannot resolve fragments bigger than 50 kb. Pulsed-field gel electrophoresis is a technique that has been developed to overcome the limitations of standard agarose gel electrophoresis. Entire linear eukaryotic chromosomes, or large fragments of a chromosome that have been generated by the action of rare-cutting restriction endonucleases, can be separated using this technique. As a result, pulsed-field gel electrophoresis has many applications, from karyotype analysis of microbial genomes, to the analysis of chromosomal strand breaks and their repair intermediates, to the study of DNA replication and the identification of origins of replication. This chapter presents a detailed protocol for the preparation of Escherichia coli chromosomal DNA that has been embedded in agarose plugs, digested with the rare-cutting endonuclease NotI, and separated by contour-clamped homogeneous field electrophoresis. The principles in this protocol can be applied to the separation of all fragments of DNA whose size range is between 40 kb and 1 Mb.

  2. Surface Charge Measurement of SonoVue, Definity and Optison: A Comparison of Laser Doppler Electrophoresis and Micro-Electrophoresis.

    Science.gov (United States)

    Ja'afar, Fairuzeta; Leow, Chee Hau; Garbin, Valeria; Sennoga, Charles A; Tang, Meng-Xing; Seddon, John M

    2015-11-01

    Microbubble (MB) contrast-enhanced ultrasonography is a promising tool for targeted molecular imaging. It is important to determine the MB surface charge accurately as it affects the MB interactions with cell membranes. In this article, we report the surface charge measurement of SonoVue, Definity and Optison. We compare the performance of the widely used laser Doppler electrophoresis with an in-house micro-electrophoresis system. By optically tracking MB electrophoretic velocity in a microchannel, we determined the zeta potentials of MB samples. Using micro-electrophoresis, we obtained zeta potential values for SonoVue, Definity and Optison of -28.3, -4.2 and -9.5 mV, with relative standard deviations of 5%, 48% and 8%, respectively. In comparison, laser Doppler electrophoresis gave -8.7, +0.7 and +15.8 mV with relative standard deviations of 330%, 29,000% and 130%, respectively. We found that the reliability of laser Doppler electrophoresis is compromised by MB buoyancy. Micro-electrophoresis determined zeta potential values with a 10-fold improvement in relative standard deviation. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Effect of degumming ph value on electrospining of silk fibroin

    Directory of Open Access Journals (Sweden)

    Lu Shen-Zhou

    2014-01-01

    Full Text Available Regenerated silk fibroin fibers show properties dependent on the molecular weight of fibroin. The cocoon-degumming approaches had great impact on the degradation of silk fibroin. The effect of degumming pH value to electrospining of fibroin was studied in this paper. The viscosity and molecular weight of regenerated silk fibroin were studied using rheometer and gel electrophoresis. The results showed that the weaker the alkalinity of degumming reagent, there was the milder the effect on silk fibroin molecular. The fibroin fibers can be prepared by electrospining with low concentration of regenerated silk fibroin solution.

  4. Characterization of Trichuris skrjabini by isoenzyme gel electrophoresis: comparative study with Trichuris ovis.

    Science.gov (United States)

    Cutillas, C; German, P; Arias, P; Guevara, D

    1996-10-01

    Morphological and biometric studies were performed in Trichuris skrjabini (Baskakov, 1924) collected from the caecum of Capra hircus. The LDH (EC 1.1.1.27.), G6PD (EC 1.1.1.49.), GPI (EC 5.3.1.9.), MDH (EC 1.1.1.37) and malic enzyme (ME) (EC 1.1.1.40) isoenzymatic patterns of T. skrjabini were determined by starch gel electrophoresis. The G6PD and GPI isoenzymatic patterns of T. skrjabini displayed two anodic bands for both enzymes: one fast migration band and one band near the origin. This isoenzymatic pattern was interpreted as two gene loci encoding both enzymes. The LDH isoenzymatic pattern of T. skrjabini was characterized by the presence of a cathodically migrating band, while the MDH isoenzymatic pattern showed a very slow cathodic band. These two phenotypes were interpreted as the expression of a homozygous state of a gene locus for LDH and MDH in T. skrjabini. The ME isoenzymatic pattern was characterized by the presence of a single anodic band. Further, comparative isoenzymatic studies were carried out between T. skrjabini and T. ovis. The different G6PD, GPI, LDH, MDH and ME isoenzymatic patterns observed for both species allowed us to distinguish them and therefore to use isoenzymatic patterns as a diagnostic tool to differentiate species of Trichuris.

  5. Plant Habitat (PH)

    Science.gov (United States)

    Onate, Bryan

    2016-01-01

    The International Space Station (ISS) will soon have a platform for conducting fundamental research of Large Plants. Plant Habitat (PH) is designed to be a fully controllable environment for high-quality plant physiological research. PH will control light quality, level, and timing, temperature, CO2, relative humidity, and irrigation, while scrubbing ethylene. Additional capabilities include leaf temperature and root zone moisture and oxygen sensing. The light cap will have red (630 nm), blue (450 nm), green (525 nm), far red (730 nm) and broad spectrum white LEDs. There will be several internal cameras (visible and IR) to monitor and record plant growth and operations.

  6. Separation and determination of flavonoids in three traditional chinese medicines by capillary electrophoresis with amperometric detection.

    Science.gov (United States)

    Wang, Wei; Lin, Ping; Ma, Lihong; Xu, Kaixuan; Lin, Xiuli

    2016-04-01

    Flavonoids are important active ingredients in many traditional Chinese medicines. In this paper, capillary electrophoresis with amperometric detection was employed to separate and detect eight flavonoids, rutin, quercetrin, quercetin, kaempferol, kaempferide, catechin, apigenin, and luteolin, in a home-made capillary electrophoresis device. Under the separation voltage of 2000 V, the eight flavonoids could be completely separated within 33 min in 18 mM borax running buffer at pH 10.2. Good linear relationships were obtained for all analytes and the detection limits for flavonoids ranged from 0.46 to 0.85 μM. Then, the method was applied to separate and determine the flavonoids in three traditional Chinese medicines, hippophae rhamnoides, hypericum perforatum, and cacumen platycladi. Finally, rutin, kaempferol, quercetin, and quercetrin were discovered in these medicines and the concentrations ranged from 0.28 to 9.94 mg/g. The recoveries of flavonoids ranged from 84.7 to 113%, which showed the high reliability of this method. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Microchip electrophoresis with amperometric detection for a novel determination of phenolic compounds in olive oil.

    Science.gov (United States)

    Godoy-Caballero, María del Pilar; Acedo-Valenzuela, María Isabel; Galeano-Díaz, Teresa; Costa-García, Agustín; Fernández-Abedul, María Teresa

    2012-11-07

    The relevance of the development of microchip electrophoresis applications in the field of food analysis is considered in this work. A novel method to determine important phenolic compounds in extra virgin olive oil samples using a miniaturized chemical analysis system is presented in this paper. Three interesting phenolic compounds in olive oil and fruit (tyrosol, hydroxytyrosol and oleuropein glucoside) were studied by end-channel amperometric detection using a 100 μm gold wire as working electrode in glass microchip electrophoresis. The electrochemical behavior of these compounds was studied and the medium to carry out their detection was selected (0.1 M aqueous sulfuric acid). The best conditions for the separation were achieved in sodium tetraborate (10% methanol, pH 9.50) with different concentrations for the sample and the running buffer in order to allow the sample stacking phenomenon. The injection was carried out using 600 V for 3 s and the separation voltage was set at 1000 V. The quality of the method was evaluated through its analytical figures of merit and by its performance on real extra virgin olive oil samples. Determination of these compounds was carried out using the standard addition calibration method with good recoveries.

  8. ssDNA degradation along capillary electrophoresis process using a Tris buffer.

    Science.gov (United States)

    Ric, Audrey; Ong-Meang, Varravaddheay; Poinsot, Verena; Martins-Froment, Nathalie; Chauvet, Fabien; Boutonnet, Audrey; Ginot, Frédéric; Ecochard, Vincent; Paquereau, Laurent; Couderc, François

    2017-06-01

    Tris-Acetate buffer is currently used in the selection and the characterization of ssDNA by capillary electrophoresis (CE). By applying high voltage, the migration of ionic species into the capillary generates a current that induces water electrolysis. This phenomenon is followed by the modification of the pH and the production of Tris derivatives. By injecting ten times by capillary electrophoresis ssDNA (50 nM), the whole oligonucleotide was degraded. In this paper, we will show that the Tris buffer in the running vials is modified along the electrophoretic process by electrochemical reactions. We also observed that the composition of the metal ions changes in the running buffer vials. This phenomenon, never described in CE, is important for fluorescent ssDNA analysis using Tris buffer. The oligonucleotides are degraded by electrochemically synthesized species (present in the running Tris vials) until it disappears, even if the separation buffer in the capillary is clean. To address these issues, we propose to use a sodium phosphate buffer that we demonstrate to be electrochemically inactive. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Simultaneous determination of phenylethanoid glycosides and aglycones by capillary zone electrophoresis with running buffer modifier.

    Science.gov (United States)

    Dong, Shuqing; Gao, Ruibin; Yang, Yan; Guo, Mei; Ni, Jingman; Zhao, Liang

    2014-03-15

    Although the separation efficiency of capillary electrophoresis (CE) is much higher than that of other chromatographic methods, it is sometimes difficult to adequately separate the complex ingredients in biological samples. This article describes how one effective and simple way to develop the separation efficiency in CE is to add some modifiers to the running buffer. The suitable running buffer modifier β-cyclodextrin (β-CD) was explored to fast and completely separate four phenylethanoid glycosides and aglycones (homovanillyl alcohol, hydroxytyrosol, 3,4-dimethoxycinnamic acid, and caffeic acid) in Lamiophlomis rotata (Lr) and Cistanche by capillary zone electrophoresis with ultraviolet (UV) detection. It was found that when β-CD was used as running buffer modifier, a baseline separation of the four analytes could be accomplished in less than 20 min and the detection limits were as low as 10(-3) mg L(-1). Other factors affecting the CE separation, such as working potential, pH value and ionic strength of running buffer, separation voltage, and sample injection time, were investigated extensively. Under the optimal conditions, a successful practical application on the determination of Lr and Cistanche samples confirmed the validity and practicability of this method. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Analytical characterization of heparin by capillary zone electrophoresis with conductivity detection and polymeric buffer additives.

    Science.gov (United States)

    Mikus, Peter; Valásková, Iva; Havránek, Emil

    2004-11-15

    A capillary zone electrophoresis (CZE) method for the analytical characterization of intact (high-molecular-weight) heparin was developed. For the first time, a hydrodynamically closed CZE separation system with conductivity detector was used for the separation, detection and quantitation of this highly sulfated, linear polysaccharide. Glycine (25mM) adjusted to pH 9.0 by bis-Tris-propane served as the running electrolyte system. Polymeric additives, polyvinylpyrrolidone (PVP), dextran (DEX), were used to improve the separation selectivity as they strongly retarded the heparin macromolecule while they did not practically influence comigrating inorganic anions. The proposed electrophoretic method was successfully validated. It was convenient for the sensitive, simple, rapid and reproducible assay of heparin in raw materials and isotonic saline. Here, the use of the conductivity detector was advantageous as it allowed heparin to be analyzed without a sample pretreatment. The CZE method should be an alternative to the pharmacopoeial conventional gel electrophoresis having used in the quality control of heparin so far. In addition, it should be convenient to quantitative estimation of heparin present in a preparation used, e.g., as the chiral selector in CE separations.

  11. Simultaneous determination of flavonoids in chrysanthemum by capillary zone electrophoresis with running buffer modifiers.

    Science.gov (United States)

    Zhang, Shan; Dong, Shuqing; Chi, Langzhu; He, Pingang; Wang, Qingjiang; Fang, Yuzhi

    2008-08-15

    Despite the separation efficiency of capillary electrophoresis (CE) is much higher than other chromatographic methods, it is sometimes difficult to perfectly separate the complex ingredients in biological samples. One possible and simple way to develop the separation effect in CE is to add some modifiers in the running buffer. In this paper, the suitable running buffer modifiers were explored to simultaneously separate and detect six typical flavonoids (apigenin, luteolin, kaempferol, quercetin, (+)-catechin and (-)-epicatechin) which are the main active ingredients in chrysanthemum by capillary zone electrophoresis with amperometric detection (CZE-AD). It was found that when beta-cyclodextrin (beta-CD) and the mixture of methanol and ethanol were used as running buffer modifiers, a baseline separation of the six analytes could be accomplished in less than 20 min and the detection limits were as low as 10(-7) or 10(-8)gm l(-1). Other factors affecting the CZE separation, such as working potential, pH value and ionic strength of running buffer, separation voltage and sample injection time were extensively investigated. Under the optimum conditions, a successful practical application on the determination of chrysanthemum samples confirmed the validity and practicability of this method.

  12. Urinary Glycosaminoglycan Electrophoresis With Optimized Keratan Sulfate Separation Using Peltier System for the Screening of Mucopolysaccharidoses

    Directory of Open Access Journals (Sweden)

    Mihriban Tijen Tanyalcin MD, PhD

    2015-10-01

    Full Text Available The purpose of this communication is to indicate a simple and rapid method with a small volume of urine sample to detect urine glycosaminoglycan (GAG and serve as a screening procedure for mucopolysaccharidoses (MPSs. Total GAG measurement for patients with MPS disorders is considered to be the first step in diagnosis of those heterogeneous group of lysosomal storage disorders presenting clinical phenotype. In this study, modified 9-dimethylmethylene blue method is used for total GAG measurement. Following GAG quantitation, the procedure described here allows GAG isolation from a very a small volume of urine sample and subjected to high-resolution GAG electrophoresis, which can be easily performed in routine clinical diagnostic laboratories. Glycosaminoglycan precipitation is a modified method based on total GAG concentration in the urine. For optimized isolation of total GAG for electrophoresis, instead of considering the urine creatinine concentration, 300 μg/mL GAG containing urine is considered to be the target concentration for the best precipitation with 1000 μL cetylpyridinium chloride (CPC/citrate buffer. Glycosaminoglycan concentration-based precipitation of urine with CPC allows the laboratory to be able to work with a small volume of urine sample by keeping the precipitating ratio with CPC constant for samples that contain GAG less than 300 μg/mL. Based on the effect of cold buffer using low voltage, GAGs high-resolution electrophoresis banding patterns described here enable a clear separation of keratan sulfate from chondroitin sulfate as well as dermatan sulfate (DS1 and DS2 and heparan sulfate. By this procedure, GAG patterns are more clear, easily identified, and provide a guide for the enzyme analysis deficient in the MPS disorders.

  13. The characteristics of transferrin variants by carbohydrate-deficient transferrin tests using capillary zone electrophoresis.

    Science.gov (United States)

    Yoo, Gilsung; Kim, Juwon; Yoon, Kap Joon; Lee, Jong-Han

    2018-04-17

    Transferrin is the major plasma transport protein for iron. We aimed to investigate the characteristics of transferrin variant by carbohydrate-deficient transferrin (CDT) test using capillary zone electrophoresis. We retrospectively analyzed the CDT tests of 2449 patients from March 2009 to May 2017 at a tertiary hospital in Korea. CDT was quantified using a Capillarys 2 system (Sebia, Lisses, France) by capillary zone electrophoresis. The characteristics of variant transferrin patterns using electropherogram of CDT tests were analyzed. Seventy-seven (3.1%) patients were classified as variant transferrin. Mean age of these patients was 51.8 years, and the male-to-female ratio was 3.5:1. The most common variants were the BC variants (n = 37), followed by the CD variants (n = 27), unclear patterns (n = 7), BD variants (n = 3), CC variants (n = 2), misclassification (n = 1). In the variant Tf group, the most common disease was alcoholic liver cirrhosis (n = 22, 28.6%), followed by the toxic effects of substances (n = 17, 22.1%), and mental and behavioral disorders attributable to alcohol (n = 11, 14.3%). Nonvariant group showed a predominance of the toxic substance effects (n = 880, 37.1%), a personal history of suicide attempts (n = 634, 26.7%), and mental and behavioral disorders due to alcohol (n = 336, 14.2%). We analyzed the basic characteristics of variant transferrin by CDT tests using capillary zone electrophoresis. The prevalence of variant transferrin was 3.1% of the study subjects. Male patients, alcohol abusers, and liver cirrhosis patients predominated in the variant transferrin population. Further prospective studies are warranted to elucidate variant transferrin in clinical practice. © 2018 Wiley Periodicals, Inc.

  14. Application of capillary electrophoresis to anion speciation in soil water extracts: 2. Arsenic

    Energy Technology Data Exchange (ETDEWEB)

    Naidu, R.; Smith, J.; McLaren, R.G.; Stevens, D.P.; Sumner, M.E.; Jackson, P.E.

    2000-02-01

    A method has been developed for the speciation of arsenic (AsO{sub 2}{sup {minus}}, AsO{sub 4}{sup 3{minus}}, and dimethylarsinic [DMA]) in natural soil solutions from contaminated sites in Australia. The separation of these anions was achieved by capillary zone electrophoresis (CZE) using a fused silica capillary with a basic chromate buffer and on-column indirect UV detection at 254 nm. Method parameters, such as electrolyte pH, run voltage, and capillary temperature were studied in order to establish suitable analytical conditions. The ideal separation for As(III) and DMA was achieved with a buffer pH of 8.0, a run voltage of 25 kV, and a capillary temperature of 30 C. Under these conditions, As(V) and orthophosphate ions comigrated. However, the use of a chromate buffer at pH 10, a run voltage of 20 kV, and capillary temperature of 20 C led to complete separation of As(V) and phosphate peaks. Results of these investigations together with recovery test data suggest that separation of the As species from soil solutions can be achieved in less than 5 min with detection limits of 0.50, 0.10, and 0.10 mg L{sup {minus}1} for As(III), As(V), and DMA, respectively.

  15. Use of quasi-isoelectric buffers to limit protein adsorption in capillary zone electrophoresis.

    Science.gov (United States)

    Poitevin, Martine; Hammad, Karim; Ayed, Ichraf; Righetti, Pier Giorgio; Peltre, Gabriel; Descroix, Stephanie

    2008-08-01

    The use of quasi-isoelectric buffers consisting of narrow pH cuts of carrier ampholytes (NC) has been investigated to limit protein adsorption on capillary walls during capillary zone electrophoresis experiments. To quantify protein adsorption on the silica surface, a method derived from that of Towns and Regnier has been developed. alpha-Lactalbumin (14 kDa, pI 4.8) and alpha-chymotrypsinogen A (25 kDa, pI 9.2) have been used as model proteins. Acidic narrow pH cuts of carrier ampholytes (NC, pH 3.0) obtained from fractionation of Serva 4-9 carrier ampholytes were used as BGE in bare-silica capillaries, and allowed to decrease significantly protein adsorption, as compared to experiments performed with classical formate buffer. The use of NC as BGE appeared to be as efficient as the use of polydimethylacrylamide coating to prevent protein adsorption. This increase of protein recovery when using NC was attributed to the interaction of carrier ampholytes with the silica surface, leading to a shielding of the capillary wall.

  16. Separation of three water-soluble vitamins by poly(dimethylsiloxane) microchannel electrophoresis with electrochemical detection.

    Science.gov (United States)

    Li, Xiang-Yun; Zhang, Qian-Li; Lian, Hong-Zhen; Xu, Jing-Juan; Chen, Hong-Yuan

    2007-09-01

    A method for rapid separation and sensitive determination of three water-soluble vitamins, pyridoxine, ascorbic acid (VC), and p-aminobenzoic acid (PABA) has been developed by PDMS microchannel electrophoresis integrated with amperometric detection. After treatment of the microchip with oxygen plasma, the peak shapes of the three analytes were essentially improved. Pyridoxine, VC, and PABA were well separated within only 80 s in a running buffer of 20 mM borate solution (pH 8.5). Good linearity was obtained within the concentration range of 2-200 microM for the three water-soluble vitamins. The detection limits were 1.0 microM for pyridoxine and VC, and 1.5 microM for PABA. The proposed method has been successfully applied to real human urine sample, without solid phase extraction, with recoveries of 80-122% for the three water-soluble vitamins.

  17. Enantioseparations of amino acids by capillary array electrophoresis with 532 nm laser induced fluorescence detection.

    Science.gov (United States)

    Liu, Kaiying; Wang, Li

    2013-06-21

    Capillary array electrophoresis (CAE) is a promising technique for multiple enantiomeric separations. Carboxytetramethylrhodamine succinimidyl ester (TAMRA SE), a rhodamine-core fluorescent probe, has rarely been applied as an original precolumn derivatization reagent for chiral amino acid (AA) analysis so far. For these purposes, high-throughput enantiomeric separations of 12 TAMRA SE-AAs by a home-made 532 nm CAE-LIF scanner are presented. The effect of cyclodextrins (CDs) and a variety of organic modifiers was quickly investigated. Baseline separations were achieved in 100 mM Tris-borate buffer (pH 10.0) containing 2 mM β-CD and 10 mM hexamethylenediamine (HDA). Multiple determination of the enantiomeric excess (ee) in non-racemic mixtures of alanine is successfully presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Improved DNA electrophoresis in conditions favoring polyborates and lewis acid complexation.

    Directory of Open Access Journals (Sweden)

    Hari Singhal

    2010-06-01

    Full Text Available Spatial compression among the longer DNA fragments occurs during DNA electrophoresis in agarose and non-agarose gels when using certain ions in the conductive buffer, impairing the range of fragment sizes resolved well in a single gel. Substitutions using various polyhydroxyl anions supported the underlying phenomenon as the complexation of Lewis acids to DNA. We saw significant improvements using conditions (lithium borate 10 mM cations, pH 6.5 favoring the formation of borate polyanions and having lower conductance and Joule heating, delayed electrolyte exhaustion, faster electrophoretic run-speed, and sharper separation of DNA bands from 100 bp to 12 kb in a single run.

  19. Dynamic computer simulations of electrophoresis: three decades of active research.

    Science.gov (United States)

    Thormann, Wolfgang; Caslavska, Jitka; Breadmore, Michael C; Mosher, Richard A

    2009-06-01

    Dynamic models for electrophoresis are based upon model equations derived from the transport concepts in solution together with user-inputted conditions. They are able to predict theoretically the movement of ions and are as such the most versatile tool to explore the fundamentals of electrokinetic separations. Since its inception three decades ago, the state of dynamic computer simulation software and its use has progressed significantly and Electrophoresis played a pivotal role in that endeavor as a large proportion of the fundamental and application papers were published in this periodical. Software is available that simulates all basic electrophoretic systems, including moving boundary electrophoresis, zone electrophoresis, ITP, IEF and EKC, and their combinations under almost exactly the same conditions used in the laboratory. This has been employed to show the detailed mechanisms of many of the fundamental phenomena that occur in electrophoretic separations. Dynamic electrophoretic simulations are relevant for separations on any scale and instrumental format, including free-fluid preparative, gel, capillary and chip electrophoresis. This review includes a historical overview, a survey of current simulators, simulation examples and a discussion of the applications and achievements of dynamic simulation.

  20. Parallel analysis and orthogonal identification of N-glycans with different capillary electrophoresis mechanisms

    International Nuclear Information System (INIS)

    Feng, Hua-tao; Su, Min; Rifai, Farida Nur; Li, Pingjing; Li, Sam F.Y.

    2017-01-01

    The deep involvement of glycans or carbohydrate moieties in biological processes makes glycan patterns an important direction for the clinical and medicine researches. A multiplexing CE mapping method for glycan analysis was developed in this study. By applying different CE separation mechanisms, the potential of combined parallel applications of capillary zone electrophoresis (CZE), micellar electrokinetic chromatography (MEKC) and capillary gel electrophoresis (CGE) for rapid and accurate identification of glycan was investigated. The combination of CZE and MEKC demonstrated enhancing chromatography separation capacity without the compromises of sample pre-treatment and glycan concentration. The separation mechanisms for multiplexing platform were selected based on the orthogonalities of the separation of glycan standards. MEKC method exhibited promising ability for the analysis of small GU value glycans and thus complementing the unavailability of CZE. The method established required only small amount of samples, simple instrument and single fluorescent labelling for sensitive detection. This integrated method can be used to search important glycan patterns appearing in biopharmaceutical products and other glycoproteins with clinical importance. - Highlights: • Cross-validation of analytes in complex samples was done with different CE separation mechanisms. • A simple strategy is used to confirm peak identification and extend capacity of CE separation. • The method uses small amount of sample, simple instrument and single fluorescent labeling. • Selection of mechanisms is based on orthogonalities of GU values of glycan standards. • Micellar electrokinetic chromatography was suitable for analysis of small or highly sialylated glycans.

  1. Parallel analysis and orthogonal identification of N-glycans with different capillary electrophoresis mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Hua-tao [Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore); NUS Environmental Research Institute, 5A Engineering Drive 1, T-Lab Building, Singapore 117411 (Singapore); Su, Min; Rifai, Farida Nur [Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore); Li, Pingjing [NUS Environmental Research Institute, 5A Engineering Drive 1, T-Lab Building, Singapore 117411 (Singapore); Li, Sam F.Y., E-mail: chmlifys@nus.edu.sg [Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543 (Singapore); NUS Environmental Research Institute, 5A Engineering Drive 1, T-Lab Building, Singapore 117411 (Singapore)

    2017-02-08

    The deep involvement of glycans or carbohydrate moieties in biological processes makes glycan patterns an important direction for the clinical and medicine researches. A multiplexing CE mapping method for glycan analysis was developed in this study. By applying different CE separation mechanisms, the potential of combined parallel applications of capillary zone electrophoresis (CZE), micellar electrokinetic chromatography (MEKC) and capillary gel electrophoresis (CGE) for rapid and accurate identification of glycan was investigated. The combination of CZE and MEKC demonstrated enhancing chromatography separation capacity without the compromises of sample pre-treatment and glycan concentration. The separation mechanisms for multiplexing platform were selected based on the orthogonalities of the separation of glycan standards. MEKC method exhibited promising ability for the analysis of small GU value glycans and thus complementing the unavailability of CZE. The method established required only small amount of samples, simple instrument and single fluorescent labelling for sensitive detection. This integrated method can be used to search important glycan patterns appearing in biopharmaceutical products and other glycoproteins with clinical importance. - Highlights: • Cross-validation of analytes in complex samples was done with different CE separation mechanisms. • A simple strategy is used to confirm peak identification and extend capacity of CE separation. • The method uses small amount of sample, simple instrument and single fluorescent labeling. • Selection of mechanisms is based on orthogonalities of GU values of glycan standards. • Micellar electrokinetic chromatography was suitable for analysis of small or highly sialylated glycans.

  2. Application of native agarose gel electrophoresis of serum proteins in veterinary diagnostics

    Directory of Open Access Journals (Sweden)

    Jania Bartosz

    2016-12-01

    Full Text Available Electrophoretic techniques, used to separate mixtures of electrically charged particles, are widely used in science. One of these techniques, native protein electrophoresis in an agarose gel, is applied in human and veterinary medicine. Changes in the proportions of individual protein fractions correspond to significant changes in the physiology of the body. Although the pattern obtained by electrophoretic separation rarely indicates a specific disease, it provides valuable information for the differential diagnosis. Decades of research on the types of patterns obtained in the case of particular diseases have led to the accumulation of substantial knowledge. The paper presents the available information on this topic. Serum protein electrophoresis is recommended in cases of increased levels of total protein in order to reveal the nature of the process. The basic information which can be obtained from electrophoretic separation includes the immune status of the organism. Both increased antigenic stimulation and immunodeficiency are clearly visible in electropherograms. Moreover, the level of heterogeneity of the corresponding protein fractions can help to distinguish between infectious diseases and cancer - multiple myeloma - the latter producing a homogeneous immunoglobulin fraction. Analysis of other protein fractions helps to detect or confirm an ongoing inflammatory process and provides information regarding liver function. Even when the concentration of total protein is within the reference range, this analysis can be recommended as a basic laboratory test.

  3. Fluorescence of soil humic acids and their fractions obtained by tandem size exclusion chromatography-polyacrylamide gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Trubetskaya, O. [Russian Academy of Sciences, Moscow Region (Russian Federation). Shemyakin and Ovchinnikov Inst. of Bioorganic Chemistry; Trubetskoj, O. [Russian Academy of Sciences, Moscow Region (Russian Federation). Inst. of Basic Biological Problems; Guyot, G.; Richard, C. [UMR CNRS 6505, Aubiere (France). Lab. de Photochimie Moleculaire et Macromoleculaire; Andreux, F. [Centre des Sciences de la Terre, Dijon (France)

    2002-07-01

    Humic acids (HAs) extracted from soils of different origin (chernozem, ferralsol and ranker) and their fractions (A, B and C+D) obtained by tandem size exclusion chromatography-polyacrylamide gel electrophoresis were investigated by steady-state fluorescence spectroscopy in the emission mode. Independently of HA source, high molecular size fractions A and B are shown to be weakly fluorescent. The main fluorophores, especially those emitting at long wavelength (around 500-510 nm), are contained in the polar and low molecular size fractions C+D. As indicated by the observed pH effect, aromatic structures bearing carboxylate and OH substituents may be involved in these longer wavelength emissions. [author].

  4. Cyclodextrine Screening for the Chiral Separation of Amlodipine Enantiomers by Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Gabriel Hancu

    2015-03-01

    Full Text Available Purpose: Amlodipine is a long acting, dihydropyridine type calcium channel blocker frequently used in the treatment of hypertension and coronary insufficiency. The calcium channel blocking activity resides primarily in the S-amlodipine enantiomer, while R-amlodipine is a potent inhibitor of smooth muscle cell migration. Methods: In this study capillary electrophoresis was applied for the enantiomeric separation of amlodipine using different native and derivatized; neutral and charged cyclodextrines as chiral selectors. The effects of pH and composition of the background electrolyte, concentration and type of chiral selector, capillary temperature, running voltage and injection parameters have been investigated. Results: Stereoselective interactions were observed when using α-CD, β-CD, HP-β-CD, RAMEB, CM-β-CD and SBE-β-CD. Optimized separation conditions consisted on a 50 mM phosphate buffer, pH – 3.0, 20 mM RAMEB as chiral selector, + 25 kV applied voltage, 15°C temperature and UV detection at 238 nm. Using the optimized electrophoretic conditions we succeeded the chiral separation of amlodipine enantiomers in approximately 6 minute, the order of migration being R-amlodipine followed by S-amlodipine. The method was successfully applied for the determination of amlodipine enantiomers from commercially available pharmaceuticals. The linearity range, limits of detection and quantification, precision and accuracy were determined and the results obtained confirmed that the method was suitable for this purpose. Conclusion: It can be concluded that the proposed capillary electrophoresis methods can be useful for routine pharmaceutical applications with benefits of its effectivity, simplicity, short analysis time and low consumption of analytes, solvents and chiral selectors.

  5. Capillary array electrophoresis using laser-excited confocal fluorescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Huang, X.C.; Quesada, M.A.; Mathies, R.A. [Univ. of California, Berkeley, CA (United States)

    1992-04-15

    Capillary electrophoresis (CE) has found widespread application in analytical and biomedical research, and the scope and sophistication of CE is still rapidly advancing. Gel-filled capillaries have been employed for the rapid separation and analysis of synthetic polynucleotides, DNA sequencing fragments, and DNA restriction fragments. Open-tube capillary electrophoresis has attained subattomole detection levels in amino acid separations 14 and proven its utility for the separation of proteins, viruses, and bacteria. Separation of the optical isomers of dansyl amino acids has also been successfully demonstrated. Micellar electrokinetic capillary chromatography, isoelectric focusing, and on-column derivatization can all be performed on CE columns, demonstrating the utility of capillary electrophoresis as an analytical and micropreparative tool. 29 refs., 6 figs., 1 tab.

  6. Magneto-paper electrophoresis in the separation of inorganic ions

    International Nuclear Information System (INIS)

    Mukherjee, H.G.; Datta, S.K.

    1983-01-01

    A comparative study of the separation of lanthanide ions by paper electrophoresis and magneto-paper electrophoresis is reported. The separation of La(III)-Gd(III), La(III)-Dy(III), Lu(III)-Gd(III), Lu(III)-Ho(III) etc. was achieved by magneto paper electrophoresis using 0.1M KCl as carrier electrolyte. Separation of different oxidation states of the same element like Cu(I)-Cu(II), Ce(III)-Ce(IV), Mn(CN) 6 3 - -Mn(CN) 6 4 - , Co(C 2 O 4 ) 2 2 - -Co(C 2 O 4 ) 3 3 - , V(CN) 6 3 - -VO(CN) 5 3 - , W(CN) 8 4 - -W(CN) 8 3 - and Ru(CN) 6 3 - Ru(CN) 6 4 - was also achieved by magneto paper electrophoretic technique using different carrier electrolytes. (Author)

  7. Synthesis of hydrogel via click chemistry for DNA electrophoresis.

    Science.gov (United States)

    Finetti, Chiara; Sola, Laura; Elliott, Jim; Chiari, Marcella

    2017-09-01

    This work introduces a novel sieving gel for DNA electrophoresis using a classical click chemistry reaction, the copper (I)-catalyzed azide-alkyne cycloaddition (CuAAC), to cross-link functional polymer chains. The efficiency of this reaction provides, under mild conditions, hydrogels with near-ideal network connectivity and improved physical properties. Hydrogel formation via click chemistry condensation of functional polymers does not involve the use of toxic monomers and UV initiation. The performance of the new hydrogel in the separation of double stranded DNA fragments was evaluated in the 2200 TapeStation system, an analytical platform, recently introduced by Agilent that combines the advantages of CE in terms of miniaturization and automation with the simplicity of use of slab gel electrophoresis. The click gel enables addition of florescent dyes prior to electrophoresis with considerable improvement of resolution and separation efficiency over conventional cross-linked polyacrylamide gels. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Electrophoresis for the analysis of heparin purity and quality.

    Science.gov (United States)

    Volpi, Nicola; Maccari, Francesca; Suwan, Jiraporn; Linhardt, Robert J

    2012-06-01

    The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Application of capillary electrophoresis to the simultaneous determination and stability study of four extensively used penicillin derivatives

    Directory of Open Access Journals (Sweden)

    Brigitta Simon

    2014-09-01

    Full Text Available The applicability of capillary electrophoresis for the analysis of four extensively used penicillin derivatives (benzylpenicillin, ampicillin, amoxicillin, oxacilllin has been studied. Because of structural similarities, the electrophoretic behavior of these derivatives is very similar; consequently an efficient separation using the conventional capillary zone electrophoresis is hard to be achieved. Their simultaneous separation was solved by using micellar electrokinetic capillary chromatography, the separation being based on the differential partition of the analytes between the micellar and aqueous phase. Using a buffer solution containing 25 mM sodium tetraborate and 100 mM sodium dodecyl sulfate as surfactant, at a pH of 9.3, applying a voltage of + 25 kV at a temperature of 25 °C, we achieved the simultaneous separation of the studied penicillin derivatives in less then 5 minutes. The separation conditions were optimized and the analytical performance of the method was evaluated in terms of precision, linearity, limit of detection, and quantification. Also, a simple capillary zone electrophoresis method was applied to study the stability of the studied penicillin derivatives in water at different temperatures, using ciprofloxacin hydrochloride as internal standard. It was observed that the extent of the hydrolysis of penicillins in water is highly dependent on the time and also temperature.

  10. A new multiphasic buffer system for benzyldimethyl-n-hexadecylammonium chloride polyacrylamide gel electrophoresis of proteins providing efficient stacking.

    Science.gov (United States)

    Kramer, Michael L

    2006-02-01

    Acidic PAGE systems using cationic detergents such as benzyldimethyl-n-hexadecylammonium chloride (16-BAC) or CTAB have proven useful for the detection of methoxy esters sensitive to alkaline pH, resolving basic proteins such as histones and membrane proteins. However, the interesting phosphate-based system suffered from poor stacking, resulting in broadened bands and long running times. Therefore, a new 16-BAC PAGE system based on the theory of moving boundary electrophoresis with properties comparable to the classical SDS-PAGE system was designed. As a result a new multiphasic analytical 16-BAC PAGE system providing efficient stacking and significantly shorter running times is presented here. It is based on acetic acid and methoxyacetic acid as common ion constituents. This PAGE system takes advantage of the additional counter stacking effect due to a cross boundary electrophoresis system resulting from the selected buffer constituents. Furthermore, the concentration of 16-BAC was optimized by determining its previously unknown CMC. Due to efficient focusing of the introduced tracking dye, methyl green, termination of electrophoresis can now be more easily followed as compared to the Schlieren line.

  11. Skin pH, Atopic Dermatitis, and Filaggrin Mutations

    DEFF Research Database (Denmark)

    Bandier, Josefine; Johansen, Jeanne Duus; Petersen, Lars Jelstrup

    2014-01-01

    mutations may influence skin pH. OBJECTIVE: We aimed to determine the epidermal pH in different groups stratified by filaggrin mutations and atopic dermatitis. Further, we investigated the changes in pH according to severity of mutational status among patients with dermatitis, irrespective of skin condition....... METHODS: pH was measured with a multiprobe system pH probe (PH 905), and the study population was composed of 67 individuals, who had all been genotyped for 3 filaggrin mutations (R501X, 2282del4, R2447X). RESULTS: We found no clear pattern in relation to filaggrin mutation carrier status. Individuals...... with wild-type filaggrin displayed both the most acidic and most alkaline values independent of concomitant skin disease; however, no statistical differences between the groups were found. CONCLUSIONS: The lack of significant diversity in skin pH in relation to filaggrin mutation carrier status suggests...

  12. Capillary Electrophoresis Single-Strand Conformational Polymorphisms as a Method to Differentiate Algal Species

    Directory of Open Access Journals (Sweden)

    Alice Jernigan

    2015-01-01

    Full Text Available Capillary electrophoresis single-strand conformational polymorphism (CE-SSCP was explored as a fast and inexpensive method to differentiate both prokaryotic (blue-green and eukaryotic (green and brown algae. A selection of two blue-green algae (Nostoc muscorum and Anabaena inaequalis, five green algae (Chlorella vulgaris, Oedogonium foveolatum, Mougeotia sp., Scenedesmus quadricauda, and Ulothrix fimbriata, and one brown algae (Ectocarpus sp. were examined and CE-SSCP electropherogram “fingerprints” were compared to each other for two variable regions of either the 16S or 18S rDNA gene. The electropherogram patterns were remarkably stable and consistent for each particular species. The patterns were unique to each species, although some common features were observed between the different types of algae. CE-SSCP could be a useful method for monitoring changes in an algae species over time as potential shifts in species occurred.

  13. Images of gel electrophoresis - RGP caps | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us RGP caps Images of gel electrophoresis Data detail Data name Images of gel electrophoresis D...OI 10.18908/lsdba.nbdc00318-05-002 Description of data contents Detailed information and images of gel electrophoresis... of each marker. Data file File name: rgp_caps_electrophoresis_image.zip File URL: ftp://ftp.biosc...iencedbc.jp/archive/rgp-caps/LATEST/rgp_caps_electrophoresis_image.zip File size:... 28.7 MB Simple search URL - Data acquisition method Gel electrophoresis Data analysis method STS markers :

  14. Describing temporal variation in reticuloruminal pH using continuous monitoring data

    OpenAIRE

    Denwood, M.J.; Kleen, J.L.; Jensen, D.B.; Jonsson, N.N.

    2018-01-01

    Reticuloruminal pH has been linked to subclinical disease in dairy cattle, leading to considerable interest in identifying pH observations below a given threshold. The relatively recent availability of continuously monitored data from pH boluses gives new opportunities for characterizing the normal patterns of pH over time and distinguishing these from abnormal patterns using more sensitive and specific methods than simple thresholds. We fitted a series of statistical models to continuously m...

  15. Capillary electrophoresis-based assessment of nanobody affinity and purity

    NARCIS (Netherlands)

    Haselberg, Rob; Oliveira, Sabrina; van der Meel, Roy; Somsen, Govert W; de Jong, Gerhardus J

    2014-01-01

    Drug purity and affinity are essential attributes during development and production of therapeutic proteins. In this work, capillary electrophoresis (CE) was used to determine both the affinity and composition of the biotechnologically produced "nanobody" EGa1, the binding fragment of a

  16. Capillary zone electrophoresis-mass spectromet of intact proteins

    NARCIS (Netherlands)

    Domínguez-Vega, Elena; Haselberg, Rob; Somsen, Govert W.

    2016-01-01

    Capillary electrophoresis (CE) coupled with mass spectrometry (MS) has proven to be a powerful analytical tool for the characterization of intact proteins. It combines the high separation efficiency, short analysis time, and versatility of CE with the mass selectivity and sensitivity offered by MS

  17. Application of a diode-array detector in capillary electrophoresis

    NARCIS (Netherlands)

    Beck, W.; Hoek, van R.; Engelhardt, H.

    1993-01-01

    In the last decade diode-array detection has proved to be extremely useful in high performance liquid chromatography in recording UV-visible spectra directly and on-line in the column effluent. In capillary electrophoresis (CE) only fast-scanning detectors with long scan times (up to 2 s) are

  18. Defining carbohydrate binding of glucan phosphatases via Affinity gel electrophoresis

    DEFF Research Database (Denmark)

    Auger, Kyle; Raththagala, Madushi; Wilkens, Casper

    2016-01-01

    was to determine a technique to measure carbohydrate binding quickly and efficiently. We established a protocol to reproducibly and quantitatively measure the binding of the enzymes to glucans utilizing Affinity Gel Electrophoresis (AGE). The results show that the various glucan phosphatases possess differing...

  19. Thermostatted dual-channel portable capillary electrophoresis instrument

    Czech Academy of Sciences Publication Activity Database

    Koenka, I.J.; Küng, N.; Kubáň, Pavel; Chwalek, T.; Furrer, G.; Wehrli, B.; Müller, B.; Hauser, P.C.

    2016-01-01

    Roč. 37, 17-18 (2016), s. 2368-2375 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : portable devices * on-site measurements * capillary electrophoresis Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 2.744, year: 2016

  20. Strain identification in Rhizobium by starch gel electrophoresis of isoenzymes

    DEFF Research Database (Denmark)

    Engvild, Kjeld Christensen; Nielsen, G.

    1985-01-01

    Sonieated extracts of rhizobia, especiaUy Rhizobium leguminosarum from pea and vetch, were run in horizontal starch gel electrophoresis in the cold. The rhizobia were grown on agar on a slime suppressing substrate of tryptone-yeast extract-CaCl2 with small amounts of mannitol, sorbitol...

  1. Capillary electrophoresis in the analysis of biologically important thiols

    Czech Academy of Sciences Publication Activity Database

    Lačná, J.; Kubáň, Petr; Foret, František

    2017-01-01

    Roč. 38, č. 1 (2017), s. 203-222 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : biological thiols * capillary electrophoresis * clinical applications Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 2.744, year: 2016

  2. Thermostatted dual-channel portable capillary electrophoresis instrument

    Czech Academy of Sciences Publication Activity Database

    Koenka, I.J.; Küng, N.; Kubáň, Pavel; Chwalek, T.; Furrer, G.; Wehrli, B.; Müller, B.; Hauser, P.C.

    2016-01-01

    Roč. 37, 17-18 (2016), s. 2368-2375 ISSN 0173-0835 Institutional support: RVO:68081715 Keywords : portable devices * on-site measurements * capillary electrophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.744, year: 2016

  3. Gel Electrophoresis--The Easy Way for Students

    Science.gov (United States)

    VanRooy, Wilhelmina; Sultana, Khalida

    2010-01-01

    This article describes a simple, inexpensive, easy to conduct gel-electrophoresis activity using food dyes. It is an alternative to the more expensive counterparts which require agarose gel, DNA samples, purchased chamber and Tris-borate-EDTA buffer. We suggest some learning activities for senior biology students along with comments on several…

  4. Serum protein fractionation using supported molecular matrix electrophoresis.

    Science.gov (United States)

    Dong, Weijie; Matsuno, Yu-ki; Kameyama, Akihiko

    2013-08-01

    Supported molecular matrix electrophoresis (SMME), in which a hydrophilic polymer such as PVA serves as a support within a porous PVDF membrane, was recently developed. This method is similar to cellulose acetate membrane electrophoresis but differs in the compatibility to glycan analysis of the separated bands. In this report, we describe the first instance of the application of SMME to human serum fractionation, and demonstrate the differences with serum fractionation by cellulose acetate membrane electrophoresis. The SMME membrane exhibited almost no EOF during electrophoresis, unlike the cellulose acetate membrane, but afforded comparative results for serum fractionation. The visualization of each fraction was achieved by conventional staining with dye such as Direct Blue-71, and objective quantification was obtained by densitometry after inducing membrane transparency with 1-nonene. Immunostaining was also achieved. Moreover, mass spectrometric analysis of both N-linked and O-linked glycans from the separated bands was demonstrated. Serum fractionation and glycan profiling of each fraction using SMME will enable novel insights into the relationships between various glycosylation profiles and disease states. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Device for Horizontal Zone Electrophoresis in Free Electrolyte

    CERN Document Server

    Priemyshev, A N; Bozhikov, G A; Alikov, B A; Salamatin, A V; Furyaev, T A; Maslov, O D; Milanov, M V; Dmitriev, S N

    2000-01-01

    With expansion of area of application of an electromigration method the necessity of modernization of installation for horizontal zone electrophoresis in free electrolyte has appeared. A number of the basic modules was essentially advanced, that has allowed considerably increase reliability and accuracy of received results. The device is completely automated.

  6. Pulsed-field gel electrophoresis typing of Staphylococcus aureus isolates

    Science.gov (United States)

    Pulsed-field gel electrophoresis (PFGE) is the most applied and effective genetic typing method for epidemiological studies and investigation of foodborne outbreaks caused by different pathogens, including Staphylococcus aureus. The technique relies on analysis of large DNA fragments generated by th...

  7. Evaluation of denaturing gradient gel electrophoresis (DGGE) used ...

    African Journals Online (AJOL)

    Denaturing gradient gel electrophoresis (DGGE) is a powerful method used to study structure of bacterial communities, without cultivation, based on the diversity of the genes coding for ribosomal RNA. However, the results are strongly dependent on the respective target region of the used primer systems. Therefore, three ...

  8. Evaluation of wheat by polyacrylamide gel electrophoresis | Shuaib ...

    African Journals Online (AJOL)

    ... polyacrylamide gel electrophoresis (SDS-PAGE). Electrophorogram for each variety were scored and presence or absence of each band noted and was entered in a binary data matrix. Based on the data of SDS-PAGE gels cluster analysis was performed to check the variations among varieties. The overall result shows ...

  9. Two-dimensional gel electrophoresis analysis of different parts of ...

    African Journals Online (AJOL)

    Two-dimensional gel electrophoresis analysis of different parts of Panax quinquefolius L. root. ... From these results it was concluded that proteomic analysis method was an effective way to identify the different parts of quinquefolius L. root. These findings may contribute to further understanding of the physiological ...

  10. Affinity Electrophoresis for Analysis of Catalytic Module-Carbohydrate Interactions

    DEFF Research Database (Denmark)

    Cockburn, Darrell; Wilkens, Casper; Svensson, Birte

    2017-01-01

    Affinity electrophoresis has long been used to study the interaction between proteins and large soluble ligands. The technique has been found to have great utility for the examination of polysaccharide binding by proteins, particularly carbohydrate binding modules (CBMs). In recent years, carbohy...

  11. Routine hemoglobin electrophoresis for pediatric surgery day case ...

    African Journals Online (AJOL)

    Background: Hemoglobin electrophoresis (HBE) is a part of the preoperative routine requested by anesthetists. However, the prevalence of hemoglobinopathy in the population is low. This study aims to determine the clinical risk factors for hemoglobinopathies and propose clinical guidelines for preoperative screening of ...

  12. PhD Dissertations

    OpenAIRE

    Redazione Reti Medievali (a cura di)

    2010-01-01

    Report of PhD Dissertations.Anna Airò La scrittura delle regole. Politica e istituzioni a Taranto nel Quattrocento, Tesi di dottorato di ricerca in Storia medievale, Università degli studi di Firenze, 2005 Pasquale Arfé La Clavis Physicae II (316-529) di Honorius Augustodunensis. Studio ed edizione critica, Tesi di dottorato in Storia della filosofia medievale, Università degli Studi di Napoli "L'Orientale", 2005 Alessandro Azzimonti Scrittura agiografica e strutture di potere nell'Italia c...

  13. A Study on Major Components of Bee Venom Using Electrophoresis

    Directory of Open Access Journals (Sweden)

    Lee, Jin-Seon

    2000-12-01

    Full Text Available This study was designed to study on major components of various Bee Venom(Bee Venom by electrical stimulation in Korea; K-BV I, Bee Venom by Microwave stimulation in Korea; K -BV II, 0.5rng/ml, Fu Yu Pharmaceutical Factory, China; C-BV, 1mg /ml, Monmouth Pain Institute, Inc., U.S.A.; A-BV using Electrophoresis. The results were summarized as follows: 1. In 1:4000 Bee Venom solution rate, the band was not displayed distinctly usmg Electrophoresis. But in 1: 1000, the band showed clearly. 2. The results of Electrophoresis at solution rate 1:1000, K-BV I and K-BVII showed similar band. 3. The molecular weight of Phospholipase A2 was known as 19,000 but its band was seen at 17,000 in Electrophoresis. 4. Protein concentration of Bee Venom by Lowry method was different at solution rate 1:4000 ; C-BV was 250μg/ml, K-BV I was 190μg/ml, K-BV Ⅱ was 160μg/ml and C-BV was 45μg/ml. 5. Electrophoresis method was unuseful for analysis of Bee Venom when solution rate is above 1:4000 but Protein concentration of Bee Venom by Lowry method was possible. These data from the study can be applied to establish the standard measurement of Bee Venom and prevent pure bee venom from mixing of another components. I think it is desirable to study more about safety of Bee Venom as time goes by.

  14. Rapid identification of Pseudomonas aeruginosa by pulsed-field gel electrophoresis.

    Science.gov (United States)

    Selim, Samy; El Kholy, Iman; Hagagy, Nashwa; El Alfay, Sahar; Aziz, Mohamed Abdel

    2015-01-02

    Twenty clinical Pseudomonas aeruginosa isolates recovered from patients admitted to The General Hospital in Ismailia Governorate (Egypt) were examined in this study. We analysed P. aeruginosa ATCC 9027 (as a control strain) and 19 of the isolates after digestion with SpeI restriction endonuclease. After this we conducted a pulsed-field gel electrophoresis (PFGE) and typed the obtained 10 unique patterns, designated as A, A1, B, B1, C, C1, D, D1, E and F. We evaluated the genetic relatedness between all strains, based on ≥87% band identity. As a result, the isolates were grouped in the 10 clusters as follows: patterns A, A1, B, B1, C contained two strains each and patterns C1, D, D1, E contained a single strain each; the five remaining strains were closely related (genomic pattern F). One isolate belonged to antibiotype 'b'. The genotype patterns of the P. aeruginosa ATCC 9027 control strain and isolate no. 11 were closely related and had two different antibiotypes 'd' and 'c', respectively.

  15. Continuous Fractionation of a two-component mixture by zone electrophoresis

    NARCIS (Netherlands)

    Zalewski, D.R.; Gardeniers, Johannes G.E.

    2009-01-01

    Synchronized continuous-flow zone electrophoresis is a recently demonstrated tool for performing electrophoretic fractionation of a complex sample. The method resembles free flow electrophoresis, but unlike in that technique, no mechanical fluid pumping is required. Instead, fast electrokinetic flow

  16. ANALYSIS OF GLYCANS DERIVED FROM GLYCOCONJUGATES BY CAPILLARY ELECTROPHORESIS-MASS SPECTROMETRY

    Science.gov (United States)

    Mechref, Yehia

    2012-01-01

    The high structural variation of glycan derived from glycoconjugates, which substantially increases with the molecular size of a protein, contributes to the complexity of glycosylation patterns commonly associated with glycoconjugates. In the case of glycoproteins, such variation originates from the multiple glycosylation sites of proteins and the number of glycan structures associated with each site (microheterogeneity). The ability to comprehensively characterize highly complex mixture of glycans has been analytically stimulating and challenging. Although the most powerful mass spectrometric (MS) and tandem MS techniques are capable of providing a wealth of structural information, they are still not able to readily identify isomeric glycan structures without high order tandem MS (MSn). The analysis of isomeric glycan structures has been attained using several separation methods, including high-pH anion exchange chromatography (HPAEC), hydrophilic interaction chromatography (HILIC) and gas chromatography (GC). However, capillary electrophoresis (CE) and microfluidics capillary electrophoresis (MCE) offer high separation efficiency and resolutions, allowing the separation of closely related glycan structures. Therefore, interfacing CE and MCE to MS is a powerful analytical approach, allowing potentially comprehensive and sensitive analysis of complex glycan samples. This review describes and discusses the utility of different CE and MCE approaches in the structural characterization of glycoproteins and the feasibility of interfacing these approaches to mass spectrometry. PMID:22180203

  17. Determination of size distribution of small DNA fragments by polyacrylamide gel electrophoresis

    International Nuclear Information System (INIS)

    Lau How Mooi

    1998-01-01

    Size distribution determination of DNA fragments can be normally determined by the agarose gel electrophoresis, including the normal DNA banding pattern analysis. However this method is only good for large DNA, such as the DNA of the size of kilo base pairs to mega base pairs range. DNA of size less than kilo base pairs is difficult to be quantified by the agarose gel method. Polyacrylamide gel electrophoresis however can be used to measure the quantity of DNA fragments of size less than kilo base pairs in length, down to less than ten base pairs. This method is good for determining the quantity of the smaller size DNA, single stranded polymers or even some proteins, if the known standards are available. In this report detail description of the method of preparing the polyacrylamide gel, and the experimental set up is discussed. Possible uses of this method, and the comparison with the standard sizes of DNA is also shown. This method is used to determine the distribution of the amount of the fragmented DNA after the Calf-thymus DNA has been exposed to various types of radiation and of different doses. The standards were used to determine the sizes of the fragmented Calf-thymus DNA. The higher the dose the higher is the amount of the smaller size DNA measured

  18. Esophageal pH monitoring

    Science.gov (United States)

    pH monitoring - esophageal; Esophageal acidity test ... Esophageal pH monitoring is used to check how much stomach acid is entering the esophagus. It also checks how well the acid is cleared downward into the ...

  19. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    Science.gov (United States)

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. [Determination of inorganic ions in explosive residues by capillary zone electrophoresis].

    Science.gov (United States)

    Feng, Junhe; Guo, Baoyuan; Lin, Jin-Ming; Xu, Jianzhong; Zhou, Hong; Sun, Yuyou; Liu, Yao; Quan, Yangke; Lu, Xiaoming

    2008-11-01

    Five anions (chlorate, perchlorate, nitrate, nitrite, and sulfate) and two cations (ammonium and potassium) in explosive residues have been separated and determined by capillary zone electrophoresis (CZE) with indirect ultraviolet detection. The electrolyte buffer for the cation separation was 10 mmol/L pyridine (pH 4.5) -3 mmol/L 18-crown-6-ether. Ammonium and potassium ions were baseline separated in less than 2.6 min with the detection limits of 0.10 mg/L and 0.25 mg/L (S/N = 3), respectively. The electrolyte buffer for the anion separation consisted of 40 mmol/L boric acid-1.8 mmol/L potassium dichromate-2 mmol/L sodium tetraborate (pH 8.6), and tetramethyl ammonium hydroxide (TMAOH) was used as electroosmotic flow modifier. All five anions were well separated in less than 4.6 min with the detection limit range of 0.10 - 1.85 mg/L (S/N = 3). The method was successfully used in real sample investigations to confirm the type of explosives.

  1. Effects of organic solvent and cationic additive on capillary electrophoresis of peptides

    International Nuclear Information System (INIS)

    Surugau, L.N.; Bergstrom, Ed T.

    2008-01-01

    Capillary electrophoresis (CE) of nine peptides namely, bradykinin, bradykinin fragment 1-5, substance P, Arg 8 -vasopressin, luteinizing hormone-releasing hormone (LHRH), bombesin, leucine-enkephalin, methionine-enkephalin and oxytocin were carried out using 0.5 % and 1.0 % formic acid (FA) as the separation buffers, added with acetonitrile (ACN) and triethylamine (TEA) as an additive at low pH. The electrophoretic behaviour of these peptides was examined at different concentration of TEA (0, 10, 20, 30, 40 and 50 mM), and ACN (30, 40, 50, 60, 70 %) at their respective measured final pH. The results showed that all nine peptides were fully resolved with addition of 10 - 20 mM TEA. Peak efficiency was improved significantly by increasing TEA concentration up to 40 mM where 800 000 m -1 was obtained. Without TEA, the closely related enkephalins were co-migrating. Interestingly, by addition of as little as 5 mM TEA has sufficient to separate them almost at baseline. Increasing ACN to 40 % has shortened the analysis time by ca. 1 min. However, further increase of ACN can cause peak broadening and current instability. (author)

  2. Effects of organic solvent and cationic additive on capillary electrophoresis of peptides

    International Nuclear Information System (INIS)

    Surugau, L.N.; Bergstrom, E.T.

    2008-01-01

    Capillary electrophoresis (CE) of nine peptides namely, bradykinin, bradykinin fragment 1-5, substance P, Arg 8 -vasopressin, luteinizing hormone-releasing hormone (LHRH), bombesin, leucine-enkephalin, methionine-enkephalin and oxytocin were carried out using 0.5 % and 1.0 % formic acid (FA) as the separation buffers, added with acetonitrile (ACN) and triethylamine (TEA) as an additive at low pH. The electrophoretic behavior of these peptides was examined at different concentration of TEA (0, 10, 20, 30, 40 and 50 mM), and ACN (30, 40, 50, 60, 70 %) at their respective measured final pH. The results showed that all nine peptides were fully resolved with addition of 10-20 mM TEA. Peak efficiency was improved significantly by increasing TEA concentration up to 40 mM where 800 000 m -1 was obtained. Without TEA, the closely related enkephalins were co-migrating. Interestingly, by addition of as little as 5 mM TEA has sufficient to separate them almost at baseline. Increasing ACN to 40 % has shortened the analysis time by ca. 1 min. However, further increase of ACN can cause peak broadening and current instability. (author)

  3. [Determination of penicillin intermediate and three penicillins in milk by high performance capillary electrophoresis].

    Science.gov (United States)

    Tian, Chunqiu; Tan, Huarong; Gao, Liping; Shen, Huqin; Qi, Kezong

    2011-11-01

    A high performance capillary electrophoresis (HPCE) method was developed for the simultaneous determination of penicillin intermediate and penicillins in milk, including 6-amino-penicillanic acid (6-APA), penicillin G (PEN), ampicillin (AMP) and amoxicillin (AMO). The main parameters including the ion concentration and pH value of running buffer, separation voltage and column temperature were optimized systematically by orthogonal test. The four penicillins (PENs) were baseline separated within 4.5 min with the running buffer of 40 mmol/L potassium dihydrogen phosphate-20 mmol/L borax solution (pH 7.8), separation voltage of 28 kV and column temperature of 30 degrees C. The calibration curves showed good linearity in the range of 1.56 - 100 mg/L, and the correlation coefficients (r2) were between 0.9979 and 0.9998. The average recoveries at three spiked levels were in the range of 84.91% - 96.72% with acceptable relative standard deviations (RSDs) of 1.11% - 9.11%. The method is simple, fast, accurate and suitable for the determination of penicillins in real samples.

  4. Analysis of aromatic aldehydes in brandy and wine by high-performance capillary electrophoresis.

    Science.gov (United States)

    Panossian, A; Mamikonyan, G; Torosyan, M; Gabrielyan, E; Mkhitaryan, S

    2001-09-01

    A new method of analysis of vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde in brandy and wine by high-performance capillary electrophoresis is described. Electrophoretic mobility of these compounds is achieved by a borate buffer at pH 9.3. At this pH, the sensitivity of UV detection of these phenolic aldehydes also increases. UV absorptions at 348, 362, 404, and 422 nm were selected for monitoring vanillin, syringaldehyde, coniferaldehyde, and sinapaldehyde, respectively. This procedure was performed simultaneously during one run using a diode array detector. Samples of brandy or wine were analyzed directly without concentration, extraction, or any other preliminary treatment of the test sample. The limits of detection were found to be 0.275, 0.1425, 0.1475, and 0.1975 ppm for syringaldehyde, coniferaldehyde, sinapaldehyde, and vanillin, respectively, which is acceptable for analysis of both brandy and wine aged in oak barrels. The method has been shown to be linear in a range from 0.3 to 57 mg/L. Recoveries ranged between 99.9% and 107.7% for all of the compounds tested. Repeatability and reproducibility of the method were high. The relative standard deviation was consequently approximately 3% and also between 4.47% and 6.89% for all tested compounds. The method is useful for the identification of counterfeit brandy, which is easy to recognize by the absence of sinapaldehyde, syringaldehyde, and coniferaldehyde, which are not detectable in false brandy.

  5. Analysis of Three Compounds in Flos Farfarae by Capillary Electrophoresis with Large-Volume Sample Stacking

    Directory of Open Access Journals (Sweden)

    Hai-xia Yu

    2017-01-01

    Full Text Available The aim of this study was to develop a method combining an online concentration and high-efficiency capillary electrophoresis separation to analyze and detect three compounds (rutin, hyperoside, and chlorogenic acid in Flos Farfarae. In order to get good resolution and enrichment, several parameters such as the choice of running buffer, pH and concentration of the running buffer, organic modifier, temperature, and separation voltage were all investigated. The optimized conditions were obtained as follows: the buffer of 40 mM NaH2P04-40 mM Borax-30% v/v methanol (pH 9.0; the sample hydrodynamic injection of up to 4 s at 0.5 psi; 20 kV applied voltage. The diode-array detector was used, and the detection wavelength was 364 nm. Based on peak area, higher levels of selective and sensitive improvements in analysis were observed and about 14-, 26-, and 5-fold enrichment of rutin, hyperoside, and chlorogenic acid were achieved, respectively. This method was successfully applied to determine the three compounds in Flos Farfarae. The linear curve of peak response versus concentration was from 20 to 400 µg/ml, 16.5 to 330 µg/mL, and 25 to 500 µg/mL, respectively. The regression coefficients were 0.9998, 0.9999, and 0.9991, respectively.

  6. Capillary zone electrophoresis-tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies

    Science.gov (United States)

    Zhu, Guijie; Sun, Liangliang; Heidbrink-Thompson, Jennifer; Kuntumalla, Srilatha; Lin, Hung-yu; Larkin, Christopher J.; McGivney, James B.; Dovichi, Norman J.

    2016-01-01

    We have evaluated capillary zone electrophoresis-electrospray ionization-tandem mass spectrometry (CZE-ESI-MS/MS) for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a five-point calibration curve by spiking twelve standard proteins into a solution of a human monoclonal antibody. A custom CZE-MS/MS system was used to analyze the tryptic digest of this mixture without depletion of the antibody. CZE generated a ~70 min separation window (~90 min total analysis duration) and ~300 peak capacity. We also analyzed the sample using ultra-performance liquid chromatography (UPLC)-MS/MS. CZE-MS/MS generated ~five times higher base peak intensity and more peptide identifications for low-level spiked proteins. Both methods detected all proteins spiked at the ~100 ppm level with respect to the antibody. PMID:26530276

  7. Evaluation of Global Genomic DNA Methylation in Human Whole Blood by Capillary Electrophoresis UV Detection

    Directory of Open Access Journals (Sweden)

    Angelo Zinellu

    2017-01-01

    Full Text Available Alterations in global DNA methylation are implicated in various pathophysiological processes. The development of simple and quick, yet robust, methods to assess DNA methylation is required to facilitate its measurement and interpretation in clinical practice. We describe a highly sensitive and reproducible capillary electrophoresis method with UV detection for the separation and detection of cytosine and methylcytosine, after formic acid hydrolysis of DNA extracted from human whole blood. Hydrolysed samples were dried and resuspended with water and directly injected into the capillary without sample derivatization procedures. The use of a run buffer containing 50 mmol/L BIS-TRIS propane (BTP phosphate buffer at pH 3.25 and 60 mmol/L sodium acetate buffer at pH 3.60 (4 : 1, v/v allowed full analyte identification within 11 min. Precision tests indicated an elevated reproducibility with an interassay CV of 1.98% when starting from 2 μg of the extracted DNA. The method was successfully tested by measuring the DNA methylation degree both in healthy volunteers and in reference calf thymus DNA.

  8. [The sequential use of local vacuum magnetotherapy and papaverine electrophoresis with sinusoidal modulated currents in impotence].

    Science.gov (United States)

    Karpukhin, I V; Bogomol'nyĭ, V A

    1997-01-01

    105 patients with chronic nonspecific prostatitis were examined and treated with papaverin electrophoresis using sinusoidal modulated currents (SMC) and local vacuum magnetotherapy (LVMT). Papaverin SMC electrophoresis and LVMT stimulated cavernous circulation. The highest stimulation was achieved at successive use of LVMT and the electrophoresis. LVMT followed by the electrophoresis maintained good cavernous circulation for 5-6 hours after the procedure in the course of which several spontaneous erections were observed.

  9. Usage of capillary electrophoresis for common hemoglobinopathies screening

    Directory of Open Access Journals (Sweden)

    Alireza Ebrahimi

    2016-06-01

    Full Text Available Hemoglobinopathies are most common inherited disorders in the world; approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. The hemoglobin disorders inherit as autosomal recessive and are very common in the Mediterranean area and much of the Asia and Africa. The control of this inherited disorders need to genetic counseling and accurate screening by more advanced and more accurate methods. This study explains features of current Iran hemoglobin disorders, nominates the accessible methods for screening them and introduces the capillary zone electrophoresis as a rapid and more accurate method. The required data were extracted of various articles and then for good explanation, current Iran hemoglobinopathies properties were showed in the tables and electropherograms of important hemoglobin disorders in Iran population were provided for help to interpretation results of blood tests by capillary zone electrophoresis method. Hemoglobin disorders are including thalassemias and hemoglobin variants; Disruption in the production and malfunction of globin chains cause types of hemoglobin disorders. We cannot introduce one of clinical laboratory tests as critical and basic method for screening and distinguishing types of inherited hemoglobin disorders as alone. For distinguishing the types of them must be prepared enough information and data of the hemoglobin disorders and for more accurate analysis must be used simultaneously different methods as gel electrophoresis, high performance liquid chromatography, isoelectric focusing, capillary zone electrophoresis or molecular tests. The capillary electrophoresis is an accurate and rapid method for screening types of the hemoglobin disorders. Other side this method cannot analyze all of them, so must be used biochemical, biophysical and molecular methods for confirmation the results. This review showed we can use the capillary electrophoresis and HPLC as two

  10. Usage of Capillary Electrophoresis for screening common Hemoglobinopathies

    Directory of Open Access Journals (Sweden)

    2016-06-01

    Full Text Available Hemoglobinopathies are most common inherited disorders in the world approximately 7 percent of the worldwide population and 5-6 percent of population of Iran are carriers. For control of this inherited hemoglobin disorders need to accurate screening by more advanced and more accurate methods. This study explains features of current Iran hemoglobin disorders, nominates the accessible methods for screening them and introduces the capillary zone electrophoresis as a rapid & more accurate method. The required data were extracted of various articles and then for good explanation, current Iran hemoglobinopathies properties were showed in the tables and electropherograms of important hemoglobin disorders in Iran population were provided for help to interpretation results of blood tests by capillary zone electrophoresis method. Hemoglobin disorders are including thalassemias & hemoglobin variants Disruption in the production and malfunction of globin chains cause types of hemoglobin disorders. We cannot introduce one of clinical laboratory tests as critical and basic method for screening and distinguishing types of inherited hemoglobin disorders as alone. For distinguishing the types of them must be prepared enough information and data of the hemoglobin disorders and for more accurate analysis must be used simultaneously different methods as Gel electrophoresis, High performance liquid chromatography, Isoelectric focusing, Capillary zone electrophoresis or molecular tests. The capillary electrophoresis is an accurate and rapid method for screening types of the hemoglobin disorders. Other side this method cannot analyze all of them, so must be used biochemical, biophysical and molecular methods for confirmation the results. This review showed we can use the capillary electrophoresis and HPLC as two complementary methods for hemoglobinopathies screening. We can analyze by the methods more hemoglobin disorders and decrease more laboratory errors. Moreover

  11. Comparison of transferrin isoform analysis by capillary electrophoresis and HPLC for screening congenital disorders of glycosylation.

    Science.gov (United States)

    Dave, Mihika B; Dherai, Alpa J; Udani, Vrajesh P; Hegde, Anaita U; Desai, Neelu A; Ashavaid, Tester F

    2018-01-01

    Transferrin, a major glycoprotein has different isoforms depending on the number of sialic acid residues present on its oligosaccharide chain. Genetic variants of transferrin as well as the primary (CDG) & secondary glycosylation defects lead to an altered transferrin pattern. Isoform analysis methods are based on charge/mass variations. We aimed to compare the performance of commercially available capillary electrophoresis CDT kit for diagnosing congenital disorders of glycosylation with our in-house optimized HPLC method for transferrin isoform analysis. The isoform pattern of 30 healthy controls & 50 CDG-suspected patients was determined by CE using a Carbohydrate-Deficient Transferrin kit. The results were compared with in-house HPLC-based assay for transferrin isoforms. Transferrin isoform pattern for healthy individuals showed a predominant tetrasialo transferrin fraction followed by pentasialo, trisialo, and disialotransferrin. Two of 50 CDG-suspected patients showed the presence of asialylated isoforms. The results were comparable with isoform pattern obtained by HPLC. The commercial controls showed a <20% CV for each isoform. Bland Altman plot showed the difference plot to be within +1.96 with no systemic bias in the test results by HPLC & CE. The CE method is rapid, reproducible and comparable with HPLC and can be used for screening Glycosylation defects. © 2017 Wiley Periodicals, Inc.

  12. Effect of pH on radiation-induced apoptosis

    International Nuclear Information System (INIS)

    Chang, W. Song; Park, Heon J.; Lyons, John C.; Auger, Elizabeth A.; Lee, Hyung-Sik

    1996-01-01

    Purpose/Objective: The effect of environmental pH on the radiation-induced apoptosis in tumor cells in vitro was investigated. Materials and Methods: SCK mammary adenocarcinoma cells of A/J mice were irradiated with γ-rays using a 137 Cs irradiator and incubated in media of different pHs. After incubation at 37 degree sign C for 24-120 hrs., the extent of apoptosis was determined using agarose gel electrophoresis of DNA, in situ TUNEL staining, flow cytometry, and release of 3 H from 3 H-thymidine labeled cells. The membrane integrity, using the trypan blue exclusion method, and the clonogenicity of the cells were also determined. Results: Irradiation with 2-12 Gy of γ-rays induced apoptosis in pH 7.5 medium within 48 hrs. The radiation-induced apoptosis progressively declined as the medium pH was lowered so that little apoptosis occurred in 48 hrs. after irradiation with 12 Gy in pH 6.6 medium. However, when the cells were irradiated and incubated for 48 hrs. in pH 6.6 medium and then medium was replaced with pH 7.5 medium, apoptosis promptly occurred. Apoptosis also occurred even in pH 6.6 medium when the cells were irradiated and maintained in pH 7.5 medium for 8 hrs. or longer post-irradiation before incubation in pH 6.6 medium. Conclusion: An acidic environment markedly suppresses radiation-induced apoptosis probably by suppressing the expression of initial signals responsible for irradiation-induced apoptosis. Indications are that the signals persist in an acidic environment and trigger apoptosis when the environmental acidity is eased. Our results suggest that the acidic environment in human tumors may inhibit the apoptosis after irradiation. However, apoptosis may be triggered when reoxygenation occurs after irradiation, and thus, the intratumor environment becomes less acidic after irradiation. Not only the change in pO 2 but the change in pH during the course of fractionated radiotherapy may greatly influence the outcome of the treatment

  13. A beta2-microglobulin cleavage variant fibrillates at near-physiological pH

    DEFF Research Database (Denmark)

    Corlin, Dorthe B; Johnsen, Christina K; Nissen, Mogens H

    2009-01-01

    Beta2-microglobulin (beta2m) deposits as amyloid in dialysis-related amyloidosis (DRA), predominantly in joints. The molecular mechanisms underlying the amyloidogenicity of beta2m are still largely unknown. In vitro, acidic conditions, pH ... several days. Here, we show that amyloid fibrils are generated in less than an hour when a cleavage variant of beta2m--found in the circulation of many dialysis patients--is exposed to pH levels (pH 6.6) occurring in joints during inflammation. Aggregation and fibrillation, including seeding effects...... with intact, native beta2m were studied by Thioflavin T fluorescence spectroscopy, turbidimetry, capillary electrophoresis, and electron microscopy. We conclude that a biologically relevant variant of beta2m is amyloidogenic at slightly acidic pH. Also, only a very small amount of preformed fibrils...

  14. Phosphoproteomics analysis of postmortem porcine muscle with pH decline rate and time difference

    DEFF Research Database (Denmark)

    Huang, Honggang; Larsen, Martin R; Karlsson, Anders H

    2012-01-01

    The aim of this study was to characterize the protein phosphorylation in postmortem (PM) muscle and reveal the change during meat quality development. The gel-based phosphoproteomic analysis of PM porcine muscle was performed in three pig groups with different pH decline rates from PM 1h to 24 h....... The sarcoplasmic and myofibrillar fractions were analyzed using gel electrophoresis in combination with a phosphoprotein specific staining. Globally, the group with fast pH decline rate had the highest phosphorylation level at PM 1 h, but lowest at PM 24 h, whereas the group with slow pH decline rate showed...... the reverse case. The phosphorylation level of 12 bands in sarcoplasmic fraction and 3 bands in myofibrillar fraction were significantly affected by the synergy effects of pH and time (p

  15. Extracting information from two-dimensional electrophoresis gels by partial least squares regression

    DEFF Research Database (Denmark)

    Jessen, Flemming; Lametsch, R.; Bendixen, E.

    2002-01-01

    of all proteins/spots in the gels. In the present study it is demonstrated how information can be extracted by multivariate data analysis. The strategy is based on partial least squares regression followed by variable selection to find proteins that individually or in combination with other proteins vary......Two-dimensional gel electrophoresis (2-DE) produces large amounts of data and extraction of relevant information from these data demands a cautious and time consuming process of spot pattern matching between gels. The classical approach of data analysis is to detect protein markers that appear...... or disappear depending on the experimental conditions. Such biomarkers are found by comparing the relative volumes of individual spots in the individual gels. Multivariate statistical analysis and modelling of 2-DE data for comparison and classification is an alternative approach utilising the combination...

  16. Discriminatory usefulness of pulsed-field gel electrophoresis and sequence-based typing in Legionella outbreaks.

    Science.gov (United States)

    Quero, Sara; García-Núñez, Marian; Párraga-Niño, Noemí; Barrabeig, Irene; Pedro-Botet, Maria L; de Simon, Mercè; Sopena, Nieves; Sabrià, Miquel

    2016-06-01

    To compare the discriminatory power of pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) in Legionella outbreaks for determining the infection source. Twenty-five investigations of Legionnaires' disease were analyzed by PFGE, SBT and Dresden monoclonal antibody. The results suggested that monoclonal antibody could reduce the number of Legionella isolates to be characterized by molecular methods. The epidemiological concordance PFGE-SBT was 100%, while the molecular concordance was 64%. Adjusted Wallace index (AW) showed that PFGE has better discriminatory power than SBT (AWSBT→PFGE = 0.767; AWPFGE→SBT = 1). The discrepancies appeared mostly in sequence type (ST) 1, a worldwide distributed ST for which PFGE discriminated different profiles. SBT discriminatory power was not sufficient verifying the infection source, especially in worldwide distributed STs, which were classified into different PFGE patterns.

  17. Alpha1-acid glycoprotein post-translational modifications: a comparative two dimensional electrophoresis based analysis

    Directory of Open Access Journals (Sweden)

    P. Roncada

    2010-04-01

    Full Text Available Alpha1-acid glycoprotein (AGP is an immunomodulatory protein expressed by hepatocytes in response to the systemic reaction that follows tissue damage caused by inflammation, infection or trauma. A proteomic approach based on two dimensional electrophoresis, immunoblotting and staining of 2DE gels with dyes specific for post-translational modifications (PTMs such as glycosylation and phosphorylation has been used to evaluate the differential interspecific protein expression of AGP purified from human, bovine and ovine sera. By means of these techniques, several isoforms have been identified in the investigated species: they have been found to change both with regard to the number of isoforms expressed under physiological condition and with regard to the quality of PTMs (i.e. different oligosaccharidic chains, presence/absence of phosphorilations. In particular, it is suggested that bovine serum AGP may have one of the most complex pattern of PTMs among serum proteins of mammals studied so far.

  18. Quasi-isoelectric buffers for protein analysis in a fast alternative to conventional capillary zone electrophoresis.

    Science.gov (United States)

    Antonioli, Paolo; Mendieta, Martha E; Sebastiano, Roberto; Citterio, Attilio; Peltre, Gabriel; Busnel, Jean-Marc; Descroix, Stephanie; Candiano, Giovanni; Righetti, Pier Giorgio

    2006-03-20

    Two different approaches are here reported for obtaining ultra-narrow pI cuts from 2-pH unit wide carrier ampholyte ranges, as commercially available, for use as quasi-isoelectric buffers in capillary electrophoresis separations of proteins. One of them uses multicompartment electrolyzers endowed with isoelectric membranes (Immobiline technology); the other employs the Rotofor equipment. Although the first approach results in more precise pI cuts, the latter technique is much faster, easier to handle and permits the immediate collection of 20 fractions in a single run. This results in ultra-narrow, ca. 0.1-pH unit intervals, uniformly spaced apart along the original wider gradient utilized for the fractionation. It is here shown that such quasi-isoelectric buffers, especially those in the pH 8-9 interval, have the unique property of coating the silica wall, thus preventing interaction of the proteins with the silica surface, that would otherwise totally disrupt the separation. On the contrary, such a shielding is not obtained in control, non isoelectric buffers (such as phosphate), that give very poor separations in uncoated capillaries. It is hypothesized that such a unique shielding effect is due to the oligo-amino backbone of the carrier ampholytes, typically composed (in the Vesterberg's synthetic approach) of 4-6 nitrogens spaced apart by ethylene moieties. Although such oligoprotic buffers should bear, in the isoelectric state, just one positive and one negative charge, they might be transiently ionized upon contact with the silanols, thus inducing a cooperative binding to the silica wall.

  19. Blood grouping based on PCR methods and agarose gel electrophoresis.

    Science.gov (United States)

    Sell, Ana Maria; Visentainer, Jeane Eliete Laguila

    2015-01-01

    The study of erythrocyte antigens continues to be an intense field of research, particularly after the development of molecular testing methods. More than 300 specificities have been described by the International Society for Blood Transfusion as belonging to 33 blood group systems. The polymerase chain reaction (PCR) is a central tool for red blood cells (RBC) genotyping. PCR and agarose gel electrophoresis are low cost, easy, and versatile in vitro methods for amplifying defined target DNA (RBC polymorphic region). Multiplex-PCR, AS-PCR (Specific Allele Polymerase Chain Reaction), and RFLP-PCR (Restriction Fragment Length Polymorphism-Polymerase Chain Reaction) techniques are usually to identify RBC polymorphisms. Furthermore, it is an easy methodology to implement. This chapter describes the PCR methodology and agarose gel electrophoresis to identify the polymorphisms of the Kell, Duffy, Kidd, and MNS blood group systems.

  20. Capillary electrophoresis microchip coupled with on-line chemiluminescence detection

    International Nuclear Information System (INIS)

    Su Rongguo; Lin Jinming; Qu Feng; Chen Zhifeng; Gao Yunhua; Yamada, Masaaki

    2004-01-01

    In the present work, chemiluminescence detection was integrated with capillary electrophoresis microchip. The microchip was designed on the principle of flow-injection chemiluminescence system and capillary electrophoresis. It has three main channels, five reservoirs and a detection cell. As model samples, dopamine and catechol were separated and detected using a permanganate chemiluminescent system on the prepared microchip. The samples were electrokinetically injected into the double-T cross section, separated in the separation channel, and then oxidized by chemiluminescent reagent delivered by a home-made micropump to produce light in the detection cell. The electroosmotic flow could be smoothly coupled with the micropump flow. The detection limits for dopamine and catechol were 20.0 and 10.0 μM, respectively. Successful separation and detection of dopamine and catechol demonstrated the distinct advantages of integration of chemiluminescent detection on a microchip for rapid and sensitive analysis

  1. Microchip Electrophoresis at Elevated Temperatures and High Separation Field Strengths

    Science.gov (United States)

    Mitra, Indranil; Marczak, Steven P.; Jacobson, Stephen C.

    2014-01-01

    We report free-solution microchip electrophoresis performed at elevated temperatures and high separation field strengths. We used microfluidic devices with 11-cm long separation channels to conduct separations at temperatures between 22 (ambient) and 45 °C and field strengths from 100 to 1000 V/cm. To evaluate separation performance, N-glycans were used as a model system and labeled with 8-aminopyrene-1,3,6-trisulfonic acid to impart charge for electrophoresis and render them fluorescent. Typically, increased diffusivity at higher temperatures leads to increased axial dispersion and poor separation performance; however, we demonstrate that sufficiently high separation field strengths can be used to offset the impact of increased diffusivity in order to maintain separation efficiency. Efficiencies for these free-solution separations are the same at temperatures of 25, 35, and 45 °C with separation field strengths ≥500 V/cm. PMID:24114979

  2. Versatile electrophoresis-based self-test platform.

    Science.gov (United States)

    Guijt, Rosanne M

    2015-03-01

    Lab on a Chip technology offers the possibility to extract chemical information from a complex sample in a simple, automated way without the need for a laboratory setting. In the health care sector, this chemical information could be used as a diagnostic tool for example to inform dosing. In this issue, the research underpinning a family of electrophoresis-based point-of-care devices for self-testing of ionic analytes in various sample matrices is described [Electrophoresis 2015, 36, 712-721.]. Hardware, software, and methodological chances made to improve the overall analytical performance in terms of accuracy, precision, detection limit, and reliability are discussed. In addition to the main focus of lithium monitoring, new applications including the use of the platform for veterinary purposes, sodium, and for creatinine measurements are included. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. An improved interface for capillary zone electrophoresis-mass spectrometry

    International Nuclear Information System (INIS)

    Smith, R.D.; Loo, J.A.; Barinaga, C.J.; Udseth, H.R.

    1988-06-01

    We have recently developed an improved electrospray ionization interface for capillary electrophoresis mass-spectrometry (CZE-MS). Our initial interface employed a vacuum deposited metal film at the exit of the capillary to make an electrical contact with he eluting buffer and establish the electrospray field gradient. This interface did, however, impose significant limitations on the range of capillary electrophoretic (CE) separations that could be performed. To circumvent these limitations, an interface that does not require a metalized tip was designed nd developed. In the new approach, the electrical contact at the column exit is made through a flowing liquid sheath. The principal advantage of this interface is that it allows operation with a much broader range of electrophoresis conditions. The sheath flow can be readily varied in both composition and volume. An electrospray ionization spectrum is given for a previously intractable buffer solution. 5 refs., 2 figs

  4. Acid-Urea Gel Electrophoresis and Western Blotting of Histones.

    Science.gov (United States)

    Hazzalin, Catherine A; Mahadevan, Louis C

    2017-01-01

    Acid-urea gel electrophoresis offers significant advantages over SDS-PAGE for analysis of post-translational protein modifications, being capable of resolving proteins of similar size but varying in charge. Hence, it can be used to separate protein variants with small charge-altering differences in primary sequence, and is particularly useful in the analysis of histones whose charge variation arises from post-translational modification, such as phosphorylation or acetylation. On acid-urea gels, histones that carry multiple modifications, each with a characteristic charge, are resolved into distinct bands, the so-called "histone ladder." Thus, the extent and distribution of different modification states of histones can be visualized. Here, we describe the analysis of histone H3 by acid-urea gel electrophoresis and western blotting.

  5. A simple gel electrophoresis method for separating polyhedral gold nanoparticles

    Science.gov (United States)

    Kim, Suhee; Lee, Hye Jin

    2015-07-01

    In this paper, a simple approach to separate differently shaped and sized polyhedral gold nanoparticles (NPs) within colloidal solutions via gel electrophoresis is described. Gel running parameters for separating efficiently gold NPs including gel composition, added surfactant types and applied voltage were investigated. The plasmonic properties and physical structure of the separated NPs extracted from the gel matrix were then investigated using transmission electron microscopy (TEM) and UV-vis spectrophotometry respectively. Data analysis revealed that gel electrophoresis conditions of a 1.5 % agarose gel with 0.1 % sodium dodecyl sulfate (SDS) surfactant under an applied voltage of 100 V resulted in the selective isolation of ~ 50 nm polyhedral shaped gold nanoparticles. Further efforts are underway to apply the method to purify biomolecule-conjugated polyhedral Au NPs that can be readily used for NP-enhanced biosensing platforms.

  6. Meta-analysis of pulsed-field gel electrophoresis fingerprints based on a constructed Salmonella database.

    Directory of Open Access Journals (Sweden)

    Wen Zou

    Full Text Available A database was constructed consisting of 45,923 Salmonella pulsed-field gel electrophoresis (PFGE patterns. The patterns, randomly selected from all submissions to CDC PulseNet during 2005 to 2010, included the 20 most frequent serotypes and 12 less frequent serotypes. Meta-analysis was applied to all of the PFGE patterns in the database. In the range of 20 to 1100 kb, serotype Enteritidis averaged the fewest bands at 12 bands and Paratyphi A the most with 19, with most serotypes in the 13-15 range among the 32 serptypes. The 10 most frequent bands for each of the 32 serotypes were sorted and distinguished, and the results were in concordance with those from distance matrix and two-way hierarchical cluster analyses of the patterns in the database. The hierarchical cluster analysis divided the 32 serotypes into three major groups according to dissimilarity measures, and revealed for the first time the similarities among the PFGE patterns of serotype Saintpaul to serotypes Typhimurium, Typhimurium var. 5-, and I 4,[5],12:i:-; of serotype Hadar to serotype Infantis; and of serotype Muenchen to serotype Newport. The results of the meta-analysis indicated that the pattern similarities/dissimilarities determined the serotype discrimination of PFGE method, and that the possible PFGE markers may have utility for serotype identification. The presence of distinct, serotype specific patterns may provide useful information to aid in the distribution of serotypes in the population and potentially reduce the need for laborious analyses, such as traditional serotyping.

  7. Sheathless interface for coupling capillary electrophoresis with mass spectrometry

    Science.gov (United States)

    Wang, Chenchen; Tang, Keqi; Smith, Richard D.

    2014-06-17

    A sheathless interface for coupling capillary electrophoresis (CE) with mass spectrometry is disclosed. The sheathless interface includes a separation capillary for performing CE separation and an emitter capillary for electrospray ionization. A portion of the emitter capillary is porous or, alternatively, is coated to form an electrically conductive surface. A section of the emitter capillary is disposed within the separation capillary, forming a joint. A metal tube, containing a conductive liquid, encloses the joint.

  8. Electrophoresis today and tomorrow: helping biologists’ dreams come true

    Czech Academy of Sciences Publication Activity Database

    Klepárník, Karel; Boček, Petr

    2010-01-01

    Roč. 32, č. 3 (2010), s. 218-226 ISSN 0265-9247 R&D Projects: GA ČR GA203/08/1536; GA AV ČR IAA400310609; GA AV ČR IAA400310703; GA AV ČR KAN400310651 Institutional research plan: CEZ:AV0Z40310501 Keywords : capillary electrophoresis * isoelectric focusing * isotachophoresis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.479, year: 2010

  9. Electrohydrodynamics and other hydrodynamic phenomena in continuous-flow electrophoresis

    International Nuclear Information System (INIS)

    Saville, D.A.

    1982-01-01

    The process known as continuous flow electrophoresis employs an electric field to separate the constituents of particulate samples suspended in a liquid. Complications arise because the electric field generates temperature gradients due to Joule heating and derives an electrohydrodynamic crossflow. Several aspects of the flow are discussed including entrance effects, hydrodynamic stability and a flow restructuring due to the combined effects of buoyancy and the crossflow. 10 references

  10. Capillary gel electrophoresis for rapid, high resolution DNA sequencing.

    OpenAIRE

    Swerdlow, H; Gesteland, R

    1990-01-01

    Capillary gel electrophoresis has been demonstrated for the separation and detection of DNA sequencing samples. Enzymatic dideoxy nucleotide chain termination was employed, using fluorescently tagged oligonucleotide primers and laser based on-column detection (limit of detection is 6,000 molecules per peak). Capillary gel separations were shown to be three times faster, with better resolution (2.4 x), and higher separation efficiency (5.4 x) than a conventional automated slab gel DNA sequenci...

  11. Rapid DNA sequencing by horizontal ultrathin gel electrophoresis.

    OpenAIRE

    Brumley, R L; Smith, L M

    1991-01-01

    A horizontal polyacrylamide gel electrophoresis apparatus has been developed that decreases the time required to separate the DNA fragments produced in enzymatic sequencing reactions. The configuration of this apparatus and the use of circulating coolant directly under the glass plates result in heat exchange that is approximately nine times more efficient than passive thermal transfer methods commonly used. Bubble-free gels as thin as 25 microns can be routinely cast on this device. The appl...

  12. New analytical portable instrument for microchip electrophoresis with electrochemical detection.

    Science.gov (United States)

    Fernández-la-Villa, Ana; Pozo-Ayuso, Diego F; Castaño-Alvarez, Mario

    2010-08-01

    A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (wxdxh) and consists of a four-outputs high voltage power supply with a maximum voltage of +/-3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth. The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.

  13. Procedures for two-dimensional electrophoresis of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Tollaksen, S.L.; Giometti, C.S.

    1996-10-01

    High-resolution two-dimensional gel electrophoresis (2DE) of proteins, using isoelectric focusing in the first dimension and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) in the second, was first described in 1975. In the 20 years since those publications, numerous modifications of the original method have evolved. The ISO-DALT system of 2DE is a high-throughput approach that has stood the test of time. The problem of casting many isoelectric focusing gels and SDS-PAGE slab gels (up to 20) in a reproducible manner has been solved by the use of the techniques and equipment described in this manual. The ISO-DALT system of two-dimensional gel electrophoresis originated in the late 1970s and has been modified many times to improve its high-resolution, high-throughput capabilities. This report provides the detailed procedures used with the current ISO-DALT system to prepare, run, stain, and photograph two-dimensional gels for protein analysis.

  14. Phylogenetic reconstruction of South American felids defined by protein electrophoresis.

    Science.gov (United States)

    Slattery, J P; Johnson, W E; Goldman, D; O'Brien, S J

    1994-09-01

    Phylogenetic associations among six closely related South American felid species were defined by changes in protein-encoding gene loci. We analyzed proteins isolated from skin fibroblasts using two-dimensional electrophoresis and allozymes extracted from blood cells. Genotypes were determined for multiple individuals of ocelot, margay, tigrina, Geoffroy's cat, kodkod, and pampas cat at 548 loci resolved by two-dimensional electrophoresis and 44 allozyme loci. Phenograms were constructed using the methods of Fitch-Margoliash and neighbor-joining on a matrix of Nei's unbiased genetic distances for all pairs of species. Results of a relative-rate test indicate changes in two-dimensional electrophoresis data are constant among all South American felids with respect to a hyena outgroup. Allelic frequencies were transformed to discrete character states for maximum parsimony analysis. Phylogenetic reconstruction indicates a major split occurred approximately 5-6 million years ago, leading to three groups within the ocelot lineage. The earliest divergence led to Leopardus tigrina, followed by a split between an ancestor of an unresolved trichotomy of three species (Oncifelis guigna, O. geoffroyi, and Lynchailuris colocolo) and a recent common ancestor of Leopardus pardalis and L. wiedii. The results suggest that modern South American felids are monophyletic and evolved rapidly after the formation of the Panama land bridge between North and South America.

  15. Factors affecting the separation performance of proteins in capillary electrophoresis.

    Science.gov (United States)

    Zhu, Yueping; Li, Zhenqing; Wang, Ping; Shen, Lisong; Zhang, Dawei; Yamaguchi, Yoshinori

    2018-04-15

    Capillary electrophoresis (CE) is an effective tool for protein separation and analysis. Compared with capillary gel electrophoresis (CGE), non-gel sieving capillary electrophoresis (NGSCE) processes the superiority on operation, repeatability and automaticity. Herein, we investigated the effect of polymer molecular weight and concentration, electric field strength, and the effective length of the capillary on the separation performance of proteins, and find that (1) polymer with high molecular weight and concentration favors the separation of proteins, although concentrated polymer hinders its injection into the channel of the capillary due to its high viscosity. (2) The resolution between the adjacent proteins decreases with the increase of electric field strength. (3) When the effective length of the capillary is long, the separation performance improves at the cost of separation time. (4) 1.4% (w/v) hydroxyethyl cellulose (HEC), 100 V/cm voltage and 12 cm effective length offers the best separation for the proteins with molecular weight from 14,400 Da to 97,400 Da. Finally, we employed the optimal electrophoretic conditions to resolve Lysozyme, Ovalbumin, BSA and their mixtures, and found that they were baseline resolved within 15 min. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Attempt to run urinary protein electrophoresis using capillary technique.

    Science.gov (United States)

    Falcone, Michele

    2014-10-01

    The study of urinary protein has a predominant place in the diagnosis of kidney disease. The most common technique is agarose gel electrophoresis (AGE). For several years, the technique of choice applied to the analysis of serum proteins has been CE, a system that uses capillary fused silica, subjected to high voltage to separate and measure serum proteins. The purpose of this paper was to perform capillary electrophoresis on urinary proteins which, at present, are not interpretable due to the many nonspecific peaks visible when using gel electrophoresis. In order to carry out our research, we used a capillary V8 analyzer together with an agarose gel system from the same company. AGE was taken as the reference method, for which urine was used without any pretreatment. For the V8 system, urine was subjected to purification on granular-activated carbon and then inserted into the V8 analyzer, selecting a program suitable for liquids with low protein content. We examined 19 urine samples collected over 24 hrs from both hospitalized and external patients with different types of proteinuria plus a serum diluted 1/61 considered as a control to recognize the bands. Both methods showed the same protein fractions and classified the proteinuria in a similar way. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. An analytical model for enantioseparation process in capillary electrophoresis

    Science.gov (United States)

    Ranzuglia, G. A.; Manzi, S. J.; Gomez, M. R.; Belardinelli, R. E.; Pereyra, V. D.

    2017-12-01

    An analytical model to explain the mobilities of enantiomer binary mixture in capillary electrophoresis experiment is proposed. The model consists in a set of kinetic equations describing the evolution of the populations of molecules involved in the enantioseparation process in capillary electrophoresis (CE) is proposed. These equations take into account the asymmetric driven migration of enantiomer molecules, chiral selector and the temporary diastomeric complexes, which are the products of the reversible reaction between the enantiomers and the chiral selector. The solution of these equations gives the spatial and temporal distribution of each species in the capillary, reproducing a typical signal of the electropherogram. The mobility, μ, of each specie is obtained by the position of the maximum (main peak) of their respective distributions. Thereby, the apparent electrophoretic mobility difference, Δμ, as a function of chiral selector concentration, [ C ] , can be measured. The behaviour of Δμ versus [ C ] is compared with the phenomenological model introduced by Wren and Rowe in J. Chromatography 1992, 603, 235. To test the analytical model, a capillary electrophoresis experiment for the enantiomeric separation of the (±)-chlorpheniramine β-cyclodextrin (β-CD) system is used. These data, as well as, other obtained from literature are in closed agreement with those obtained by the model. All these results are also corroborate by kinetic Monte Carlo simulation.

  18. Detecting irradiation of seeds using microgel electrophoresis (a collaborative trial)

    International Nuclear Information System (INIS)

    Cerda, H.; Haine, H.E.; Jones, J.L.

    1995-06-01

    Preservation of certain foods by irradiation is permitted in the United Kingdom. However, all irradiated foods must be labelled as such, to ensure consumer choice. To help enforce labelling, a variety of methods have been developed for distinguishing between irradiated and non-irradiated foods. In preliminary trials, microgel electrophoresis -a simple method of assessing DNA damage - has shown considerable promise in this respect. This report describes microgel electrophoresis, and details results obtained in a blind trial carried out in collaboration with the Swedish University of Agricultural Sciences. Microgel electrophoresis facilitates analysis of the leakage of DNA from cells extracted from food material. In irradiated samples, the DNA is fragmented and will leak from cells in an electric current. This leakage can be seen as a 'comet' when the stained gel is viewed with a microscope. The size and shape of the comet can be used to estimate the irradiation dose administered to the sample. In non-irradiated samples the DNA is less fragmented, will tend not to leak from the cells and will not form a comet. (author)

  19. Automated Lab-on-a-Chip Electrophoresis System

    Science.gov (United States)

    Willis, Peter A.; Mora, Maria; Greer, Harold F.; Fisher, Anita M.; Bryant, Sherrisse

    2012-01-01

    Capillary electrophoresis is an analytical technique that can be used to detect and quantify extremely small amounts of various biological molecules. In the search for biochemical traces of life on other planets, part of this search involves an examination of amino acids, which are the building blocks of life on Earth. The most sensitive method for detecting amino acids is the use of laser induced fluorescence. However, since amino acids do not, in general, fluoresce, they first must be reacted with a fluorescent dye label prior to analysis. After this process is completed, the liquid sample then must be transported into the electrophoresis system. If the system is to be reused multiple times, samples must be added and removed each time. In typical laboratories, this process is performed manually by skilled human operators using standard laboratory equipment. This level of human intervention is not possible if this technology is to be implemented on extraterrestrial targets. Microchip capillary electrophoresis (CE) combined with laser induced fluorescence detection (LIF) was selected as an extremely sensitive method to detect amino acids and other compounds that can be tagged with a fluorescent dye. It is highly desirable to package this technology into an integrated, autonomous, in situ instrument capable of performing CE-LIF on the surface of an extraterrestrial body. However, to be fully autonomous, the CE device must be able to perform a large number of sample preparation and analysis operations without the direct intervention of a human.

  20. PhD Dissertations

    Directory of Open Access Journals (Sweden)

    Redazione Reti Medievali (a cura di

    2004-06-01

    Full Text Available Report of PhD Dissertations. Francesco Barone Istituzioni, società ed economia a Catania nel tardo medioevo (XIV-XV secolo, Tesi di dottorato in Storia medievale (XVI ciclo, Università degli Studi di Firenze, 2004   Laura Berti Ceroni Il territorio e le strutture di Cesarea e Classe tra tarda antichità e alto medioevo in rapporto con Ravenna, Tesi di dottorato di ricerca in Storia e Informatica, Università degli studi di Bologna, 2002-2003.   Marco Bicchierai Poppi dalla signoria dei conti Guidi al vicariato del Casentino (1360-1480, Tesi di dottorato in Storia medievale (XIV ciclo, Università degli Studi di Firenze, 2004   Emanuela Garimberti Spatiosa ad habitandum loca. Luoghi e identità nella Historia Langobardorum di Paolo Diacono, Tesi di dottorato in Storia medievale (XV ciclo, Università degli Studi di Bologna, 2004   Lorenzo Tanzini Sistemi normativi e pratiche istituzionali a Firenze dalla fine del XIII all’inizio del XV secolo, Tesi di dottorato di ricerca in Storia medievale (XVI ciclo, Università degli Studi di Firenze, 2004   Stefania Tarquini Pellegrinaggio e asseto urbano di Roma, Tesi di dottorato di ricerca in Storia dei centri, delle vie e della cultura dei pellegrinaggi nel Medioevo euro mediterraneo (XV ciclo, Università degli studi di Lecce, 2003

  1. PhD Dissertations

    Directory of Open Access Journals (Sweden)

    Redazione Reti Medievali (a cura di

    2010-06-01

    Full Text Available Report of PhD dissertations. Andrea Brugnoli Una storia locale: l’organizzazione del territorio veronese nel medioevo: trasformazioni della realtà e schemi notarili (IX-metà XII secolo, Tesi di dottorato di ricerca in Scienze Storiche e Antropologiche (XXII ciclo, Università degli Studi di Verona, 2010   Luca Filangieri Famiglie e gruppi dirigenti a Genova (secoli XII-metà XIII, Tesi di dottorato di ricerca in Storia medievale (XXII ciclo, Università degli Studi di Firenze, 2010   Jakub Kujawi ski Wernakularna kolekcja historiograficzna z rękopisu francuskiego nr 688 z Biblioteki Narodowej w Paryżu. Studium źródłoznawcze (La raccolta dei volgarizzamenti delle opere storiografiche nel manoscritto francese 688 della Biblioteca Nazionale di Parigi, Tesi di dottorato, Università “Adam Mickiewicz”, Facoltà di Storia, Pozna, a.a. 2009/2010   Marta Longhi I signori “de Radicata”. Strategie di affermazione familiare e patrimoniale nel Piemonte dei secoli XII-XIV, Tesi di dottorato di ricerca in Istituzioni, Società, Religioni dal Tardo Antico alla fine del Medioevo (XX ciclo, Università di Torino, 2008

  2. PhD Dissertations

    Directory of Open Access Journals (Sweden)

    Redazione Reti Medievali (a cura di

    2003-06-01

    Full Text Available Reporto of PhD Dissertations.   Mario Dalle Carbonare Società, potere e clientele nell’Irlanda altomedievale (secoli V-IX, Tesi di dottorato di ricerca in Storia sociale europea, Università "Ca' Foscari" di Venezia, 2003 Vieri Mazzoni La legislazione antighibellina e la politica oligarchica della Parte Guelfa di Firenze nel secondo Trecento (1347-1378, Tesi di dottorato di ricerca in Storia Medievale (ciclo XII, Università degli Studi di Firenze   Alma Poloni Pisa dalle origini del movimento popolare alla discesa di Ludovico il Bavaro. I gruppi dirigenti cittadini tra continuità e trasformazione, Tesi di dottorato di ricerca in Storia dell'Europa nel medioevo, Università degli studi di Pisa, 2003   Andrea Puglia Potere marchionale, amministrazione del territorio, società locali dalla morte di Ugo di Tuscia a Guelfo VI di Baviera (1001-1160, Tesi di dottorato di ricerca in Storia medievale, Università degli studi di Milano, 2003

  3. Comparison of lipoprotein electrophoresis and apolipoprotein e genotyping in investigating dysbetalipoproteinemia

    International Nuclear Information System (INIS)

    Ahmed, F.; Kadiki, A.E.

    2017-01-01

    Dysbetalipoproteinemia is often associated with apolipoprotein E2E2 homozygosity; however, lipoprotein electrophoresis may also be used to assist in the diagnosis. The aim of this study was to compare apolipoprotein E (apo E) genotyping and lipoprotein electrophoresis in investigating dysbetalipoproteinemia. Data were collected over a three-year period from a lipid clinic in a tertiary referral centre and reviewed for apo E genotyping and lipoprotein electrophoresis. Sixty-two patients had both apo E genotyping and lipoprotein electrophoresis. Of these, 16 patients showed broad beta band on electrophoresis. However, only 3 of them had apo E2E2 homozygosity on genotyping. Lipoprotein electrophoresis and apo E genotyping results showed poor concordance. This was primarily due to visual interpretation error of lipoprotein electrophoresis which may over diagnose dysbetalipoproteinemia. (author)

  4. Comparison of Lipoprotein Electrophoresis and Apolipoprotein E Genotyping in Investigating Dysbetalipoproteinemia.

    Science.gov (United States)

    Ahmed, Farhan; El-Kadiki, Alia; Gibbons, Stephen

    2017-06-01

    Dysbetalipoproteinemia is often associated with apolipoprotein E2E2 homozygosity; however, lipoprotein electrophoresis may also be used to assist in the diagnosis. The aim of this study was to compare apolipoprotein E (apo E) genotyping and lipoprotein electrophoresis in investigating dysbetalipoproteinemia. Data were collected over a three-year period from a lipid clinic in a tertiary referral centre and reviewed for apo E genotyping and lipoprotein electrophoresis. Sixty-two patients had both apo E genotyping and lipoprotein electrophoresis. Of these, 16 patients showed broad beta band on electrophoresis. However, only 3 of them had apo E2E2 homozygosity on genotyping. Lipoprotein electrophoresis and apo E genotyping results showed poor concordance. This was primarily due to visual interpretation error of lipoprotein electrophoresis which may over diagnose dysbetalipoproteinemia.

  5. Applications of space-electrophoresis in medicine. [for cellular separations in molecular biology

    Science.gov (United States)

    Bier, M.

    1976-01-01

    The nature of electrophoresis is reviewed and potential advances realizable in the field of biology and medicine from a space electrophoresis facility are examined. The ground-based applications of electrophoresis: (1) characterization of an ionized species; (2) determination of the quantitative composition of a complex mixture; and (3) isolation of the components of a mixture, separation achieved on the basis of the difference in transport rates is reviewed. The electrophoresis of living cells is considered, touching upon the following areas: the separation of T and B lymphocytes; the genetic influence on mouse lymphocyte mobilities; the abnormal production of specific and monoclonal immunoproteins; and the study of cancer. Schematic diagrams are presented of three types of electrophoresis apparatus: the column assembly for the static electrophoresis experiment on the Apollo-Soyuz mission, the continuous flow apparatus used in the same mission and a miniaturized electrophoresis apparatus.

  6. Electrophoretic analysis of proteins from Mycoplasma hominis strains detected by SDS-PAGE, two-dimensional gel electrophoresis and immunoblotting

    DEFF Research Database (Denmark)

    Andersen, H; Birkelund, Svend; Christiansen, Gunna

    1987-01-01

    The proteins of 14 strains of Mycoplasma hominis were compared by SDS-PAGE in gradient gels, by two-dimensional (2D) gel electrophoresis of extracts of 35S-labelled cells and by immunoblot analysis of cell proteins. The strains examined included the M. hominis type strain PG21 and 13 others...... isolated variously from genital tract, mouth, blood, upper urinary tract and a wound. These 14 strains shared 76-99% of proteins in SDS-gradient gel analysis and 41-72% in the 2D gels. As expected, the immunoblot analysis likewise revealed the existence of an extensive common protein pattern in M. hominis...

  7. Amino Acid Composition, Molecular Weight Distribution and Gel Electrophoresis of Walnut (Juglans regia L. Proteins and Protein Fractionations

    Directory of Open Access Journals (Sweden)

    Xiaoying Mao

    2014-01-01

    Full Text Available As a by-product of oil production, walnut proteins are considered as an additional source of plant protein for human food. To make full use of the protein resource, a comprehensive understanding of composition and characteristics of walnut proteins are required. Walnut proteins have been fractionated and characterized in this study. Amino acid composition, molecular weight distribution and gel electrophoresis of walnut proteins and protein fractionations were analyzed. The proteins were sequentially separated into four fractions according to their solubility. Glutelin was the main component of the protein extract. The content of glutelin, albumin, globulin and prolamin was about 72.06%, 7.54%, 15.67% and 4.73% respectively. Glutelin, albumin and globulin have a balanced content of essential amino acids, except for methionine, with respect to the FAO pattern recommended for adults. SDS-PAGE patterns of albumin, globulin and glutelin showed several polypeptides with molecular weights 14.4 to 66.2 kDa. The pattern of walnut proteins in two-dimension electrophoresis (2-DE showed that the isoelectric point was mainly in the range of 4.8–6.8. The results of size exclusion chromatogram indicated molecular weight of the major components of walnut proteins were between 3.54 and 81.76 kDa.

  8. Simultaneous determination of caffeine, paracetamol, and ibuprofen in pharmaceutical formulations by high-performance liquid chromatography with UV detection and by capillary electrophoresis with conductivity detection.

    Science.gov (United States)

    Cunha, Rafael R; Chaves, Sandro C; Ribeiro, Michelle M A C; Torres, Lívia M F C; Muñoz, Rodrigo A A; Dos Santos, Wallans T P; Richter, Eduardo M

    2015-05-01

    Paracetamol, caffeine and ibuprofen are found in over-the-counter pharmaceutical formulations. In this work, we propose two new methods for simultaneous determination of paracetamol, caffeine and ibuprofen in pharmaceutical formulations. One method is based on high-performance liquid chromatography with diode-array detection and the other on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation by high-performance liquid chromatography with diode-array detection was achieved on a C18 column (250×4.6 mm(2), 5 μm) with a gradient mobile phase comprising 20-100% acetonitrile in 40 mmol L(-1) phosphate buffer pH 7.0. The separation by capillary electrophoresis with capacitively coupled contactless conductivity detection was achieved on a fused-silica capillary (40 cm length, 50 μm i.d.) using 10 mmol L(-1) 3,4-dimethoxycinnamate and 10 mmol L(-1) β-alanine with pH adjustment to 10.4 with lithium hydroxide as background electrolyte. The determination of all three pharmaceuticals was carried out in 9.6 min by liquid chromatography and in 2.2 min by capillary electrophoresis. Detection limits for caffeine, paracetamol and ibuprofen were 4.4, 0.7, and 3.4 μmol L(-1) by liquid chromatography and 39, 32, and 49 μmol L(-1) by capillary electrophoresis, respectively. Recovery values for spiked samples were between 92-107% for both proposed methods. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Proteomic study of muscle sarcoplasmic proteins using AUT-PAGE/SDS-PAGE as two-dimensional gel electrophoresis.

    Science.gov (United States)

    Picariello, Gianluca; De Martino, Alessandra; Mamone, Gianfranco; Ferranti, Pasquale; Addeo, Francesco; Faccia, Michele; Spagnamusso, Salvatore; Di Luccia, Aldo

    2006-03-20

    In the present study, an alternative procedure for two-dimensional (2D) electrophoretic analysis in proteomic investigation of the most represented basic muscle water-soluble proteins is suggested. Our method consists of Acetic acid-Urea-Triton polyacrylamide gel (AUT-PAGE) analysis in the first dimension and standard sodium dodecyl sulphate polyacrylamide gel (SDS-PAGE) in the second dimension. Although standard two-dimensional Immobilized pH Gradient-Sodium Dodecyl-Sulphate (2D IPG-SDS) gel electrophoresis has been successfully used to study these proteins, most of the water-soluble proteins are spread on the alkaline part of the 2D map and are poorly focused. Furthermore, the similarity in their molecular weights impairs resolution of the classical approach. The addition of Triton X-100, a non-ionic detergent, into the gel induces a differential electrophoretic mobility of proteins as a result of the formation of mixed micelles between the detergent and the hydrophobic moieties of polypeptides, separating basic proteins with a criterion similar to reversed phase chromatography based on their hydrophobicity. The acid pH induces positive net charges, increasing with the isoelectric point of proteins, thus allowing enhanced resolution in the separation. By using 2D AUT-PAGE/SDS electrophoresis approach to separate water-soluble proteins from fresh pork and from dry-cured products, we could spread proteins over a greater area, achieving a greater resolution than that obtained by IPG in the pH range 3-10 and 6-11. Sarcoplasmic proteins undergoing proteolysis during the ripening of products were identified by Matrix Assisted Laser Desorption/Ionization-Time of Flight (MALDI-ToF) mass spectrometry peptide mass fingerprinting in a easier and more effective way. Two-dimensional AUT-PAGE/SDS electrophoresis has allowed to simplify separation of sarcoplasmic protein mixtures making this technique suitable in the defining of quality of dry-cured pork products by immediate

  10. A PhD is a PhD is a PhD

    OpenAIRE

    Ostrow, Deborah Anne

    2017-01-01

    A PhD is a PhD is a PhD is a practice-based project that interrogates the process of an artist undertaking PhD research under established criteria. It consists of an exegesis, an original screenplay, and a digital film made for online viewing, with images drawn from a range of documentaries and films found on YouTube. They have been dissected, re-assembled and then re-embedded to YouTube. The source material covers topics such as medicalization of madness, the conspicuous appropriation of uni...

  11. The pH Game.

    Science.gov (United States)

    Chemecology, 1996

    1996-01-01

    Describes a game that can be used to teach students about the acidity of liquids and substances around their school and enable them to understand what pH levels tell us about the environment. Students collect samples and measure the pH of water, soil, plants, and other natural material. (DDR)

  12. Characterisation of aqueous waste produced during the clandestine production of amphetamine following the Leuckart route utilising solid-phase extraction gas chromatography-mass spectrometry and capillary electrophoresis with contactless conductivity detection.

    Science.gov (United States)

    Hauser, Frank M; Hulshof, Janneke W; Rößler, Thorsten; Zimmermann, Ralf; Pütz, Michael

    2018-04-18

    Chemical waste from the clandestine production of amphetamine is of forensic and environmental importance due to its illegal nature which often leads to dumping into the environment. In this study, 27 aqueous amphetamine waste samples from controlled Leuckart reactions performed in Germany, the Netherlands, and Poland were characterised to increase knowledge about the chemical composition and physicochemical characteristics of such waste. Aqueous waste samples from different reaction steps were analysed to determine characteristic patterns which could be used for classification. Conductivity, pH, density, ionic load, and organic compounds were determined using different analytical methods. Conductivity values ranged from 1 to over 200 mS/cm, pH values from 0 to 14, and densities from 1.0 to 1.3 g/cm 3 . A capillary electrophoresis method with contactless conductivity detection (CE-C 4 D) was developed and validated to quantify chloride, sulphate, formate, ammonium, and sodium ions which were the most abundant ions in the investigated waste samples. A solid-phase extraction sample preparation was used prior to gas chromatography-mass spectrometry analysis to determine the organic compounds. Using the characterisation data of the known samples, it was possible to assign 16 seized clandestine waste samples from an amphetamine production to the corresponding synthesis step. The data also allowed us to draw conclusions about the synthesis procedure and used chemicals. The presented data and methods could support forensic investigations by showing the probative value of synthesis waste when investigating the illegal production of amphetamine. It can also act as starting point to develop new approaches to tackle the problem of clandestine waste dumping. Copyright © 2018 John Wiley & Sons, Ltd.

  13. Recent progress in preparation and application of microfluidic chip electrophoresis

    International Nuclear Information System (INIS)

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao

    2015-01-01

    Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast. (topical review)

  14. Two-dimensional polyacrylamide gel electrophoresis of intracellular proteins

    International Nuclear Information System (INIS)

    Ojima, N.; Sakamoto, T.; Yamashita, M.

    1996-01-01

    Since two-dimensional electrophoresis was established by O'Farrell for analysis of intracellular proteins of Escherichia coli, it has been applied to separation of proteins of animal cells and tissues, and especially to identification of stress proteins. Using this technique, proteins are separated by isoelectric focusing containing 8 m urea in the first dimension and by SDS-PAGE in the second dimension. The gels are stained with Coomassie Blue R-250 dye, followed by silver staining. In the case of radio-labeled proteins, the gels are dried and then autoradiographed. In order to identify a specific protein separated by two-dimensional electrophoresis, a technique determining the N-terminal amino acid sequence of the protein has been developed recently. After the proteins in the gel were electrotransferred to a polyvinylidene difluoride membrane, the membrane was stained for protein with Commassie Blue and a stained membrane fragment was applied to a protein sequencer. Our recent studies demonstrated that fish cells newly synthesized various proteins in response to heat shock, cold nd osmotic stresses. For example, when cellular proteins extracted from cold-treated rainbow trout cells were subjected to two-dimensional gel electrophoresis, the 70 kDa protein was found to be synthesized during the cold-treatment. N-Terminal sequence analysis showed that the cold-inducible protein was a homolog of mammalian valosin-containing protein and yeast cell division cycle gene product CDC48p. Furthermore, the sequence data were useful for preparing PCR primers and a rabbit antibody against a synthetic peptide to analyze a role for the protein in the function of trout cells and mechanisms for regulation

  15. Recent progress in preparation and application of microfluidic chip electrophoresis

    Science.gov (United States)

    Cong, Hailin; Xu, Xiaodan; Yu, Bing; Yuan, Hua; Peng, Qiaohong; Tian, Chao

    2015-05-01

    Since its discovery in 1990, microfluidic chip electrophoresis (MCE) has allowed the development of applications with small size, fast analysis, low cost, high integration density and automatic level, which are easy to carry and have made commercialization efficient. MCE has been widely used in the areas of environmental protection, biochemistry, medicine and health, clinical testing, judicial expertise, food sanitation, pharmaceutical checking, drug testing, agrochemistry, biomedical engineering and life science. As one of the foremost fields in the research of capillary electrophoresis, MCE is the ultimate frontier to develop the miniaturized, integrated, automated all-in-one instruments needed in modern analytical chemistry. By adopting the advanced technologies of micro-machining, lasers and microelectronics, and the latest research achievements in analytical chemistry and biochemistry, the sampling, separation and detection systems of commonly used capillary electrophoresis are integrated with high densities onto glass, quartz, silicon or polymer wafers to form the MCE, which can finish the analysis of multi-step operations such as injection, enrichment, reaction, derivatization, separation, and collection of samples in a portable, efficient and super high speed manner. With reference to the different technological achievements in this area, the latest developments in MCE are reviewed in this article. The preparation mechanisms, surface modifications, and properties of different materials in MCE are compared, and the different sampling, separation and detection systems in MCE are summarized. The performance of MCE in analysis of fluorescent substance, metallic ion, sugar, medicine, nucleic acid, DNA, amino acid, polypeptide and protein is discussed, and the future direction of development is forecast.

  16. Determination of nitrate and nitrite in Hanford defense waste (HDW) by reverse polarity capillary zone electrophoresis (RPCE) method

    International Nuclear Information System (INIS)

    Metcalf, S.G.

    1998-01-01

    This paper describes the first application of reverse polarity capillary zone electrophoresis (RPCE) for rapid and accurate determination of nitrate and nitrite in Hanford Defense Waste (HDW). The method development was carried out by using Synthetic Hanford Waste (SHW), followed by the analysis of 4 real HDW samples. Hexamethonium bromide (HMB) was used as electroosmotic flow modifier in borate buffer at pH 9.2 to decrease the electroosmotic flow (EOF) in order to enhance the speed of analysis and the resolution of nitrate and nitrite in high ionic strength HDW samples. The application of this capillary zone electrophoresis method, when compared with ion chromatography for two major components of HDW, nitrate and nitrite slightly reduced analysis time, eliminated most pre-analysis handling of the highly radioactive sample, and cut analysis wastes by more than 2 orders of magnitude. The analysis of real HDW samples that were validated by using sample spikes showed a concentration range of 1.03 to 1.42 M for both nitrate. The migration times of the real HDW and the spiked HDW samples were within a precision of less than 3% relative standard deviation. The selectivity ratio test used for peak confirmation of the spiked samples was within 96% of the real sample. Method reliability was tested by spiking the matrix with 72.4 mM nitrate and nitrite. Recoveries for these spiked samples were 93-103%

  17. A method for easily customizable gradient gel electrophoresis.

    Science.gov (United States)

    Miller, Andrew J; Roman, Brandon; Norstrom, Eric

    2016-09-15

    Gradient polyacrylamide gel electrophoresis is a powerful tool for the resolution of polypeptides by relative mobility. Here, we present a simplified method for generating polyacrylamide gradient gels for routine analysis without the need for specialized mixing equipment. The method allows for easily customizable gradients which can be optimized for specific polypeptide resolution requirements. Moreover, the method eliminates the possibility of buffer cross contamination in mixing equipment, and the time and resources saved with this method in place of traditional gradient mixing, or the purchase of pre-cast gels, are noteworthy given the frequency with which many labs use gradient gel SDS-PAGE. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Human muscle proteins: analysis by two-dimensional electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Giometti, C.S.; Danon, M.J.; Anderson, N.G.

    1983-09-01

    Proteins from single frozen sections of human muscle were separated by two-dimensional gel electrophoresis and detected by fluorography or Coomassie Blue staining. The major proteins were identical in different normal muscles obtained from either sex at different ages, and in Duchenne and myotonic dystrophy samples. Congenital myopathy denervation atrophy, polymyositis, and Becker's muscular dystrophy samples, however, showed abnormal myosin light chain compositions, some with a decrease of fast-fiber myosin light chains and others with a decrease of slow-fiber light chains. These protein alterations did not correlate with any specific disease, and may be cause by generalized muscle-fiber damage.

  19. Multivalent weak electrolytes - risky background electrolytes for capillary zone electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Beckers, J. L.; Boček, Petr

    2002-01-01

    Roč. 23, č. 12 (2002), s. 1942-1946 ISSN 0173-0835 R&D Projects: GA ČR GA203/99/0044; GA ČR GA203/02/0023; GA ČR GA203/01/0401; GA AV ČR IAA4031703; GA AV ČR IAA4031103 Institutional research plan: CEZ:AV0Z4031919 Keywords : background electrolytes * capillary zone electrophoresis * multivalent electrolytes Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.325, year: 2002

  20. Separation and quantification of cellulases and hemicellulases by capillary electrophoresis

    DEFF Research Database (Denmark)

    Jørgensen, Henning; Kutter, Jörg Peter; Olsson, Lisbeth

    2003-01-01

    Cellulases and hemicellulases are two classes of enzymes produced by filamentous fungi and secreted into the cultivation medium. Both classes of enzymes consist of a subset of classes of which the fungi produce several enzymes with varying molecular mass and pI but similar enzymatic activities....... Current methods are limited in their ability to quantify all of these enzymes when all are present simultaneously in a mixture. Five different cellulases (two cellobiohydrolases and three endoglucanases) and one hemicellulase (endoxylanase) were separated using capillary electrophoresis (CE) in a fused...

  1. Capillary electrophoresis-MALDI interface based on inkjet technology

    Science.gov (United States)

    Vannatta, Michael W.; Whitmore, Colin D.; Dovichi, Norman J.

    2010-01-01

    An ink jet printer valve and nozzle were used to deliver matrix and sample from an electrophoresis capillary onto a MALDI plate. The system was evaluated by separation of a set of standard peptides. That separation generated up to 40,000 theoretical plates in less than three minutes. Detection limits were 500 amol using an ABI TOF-TOF instrument and 2 fmol for an ABI Q-TOF instrument. Over 70% coverage was obtained for the tryptic digest of α-lactalbumin in less than 2.5 minutes. PMID:19960472

  2. Recent advances of capillary electrophoresis in pharmaceutical analysis.

    Science.gov (United States)

    Suntornsuk, Leena

    2010-09-01

    This review covers recent advances of capillary electrophoresis (CE) in pharmaceutical analysis. The principle, instrumentation, and conventional modes of CE are briefly discussed. Advances in the different CE techniques (non-aqueous CE, microemulsion electrokinetic chromatography, capillary isotachophoresis, capillary electrochromatography, and immunoaffinity CE), detection techniques (mass spectrometry, light-emitting diode, fluorescence, chemiluminescence, and contactless conductivity), on-line sample pretreatment (flow injection) and chiral separation are described. Applications of CE to assay of active pharmaceutical ingredients (APIs), drug impurity testing, chiral drug separation, and determination of APIs in biological fluids published from 2008 to 2009 are tabulated.

  3. Capillaries for use in a multiplexed capillary electrophoresis system

    Science.gov (United States)

    Yeung, E.S.; Chang, H.T.; Fung, E.N.

    1997-12-09

    The invention provides a side-entry optical excitation geometry for use in a multiplexed capillary electrophoresis system. A charge-injection device is optically coupled to capillaries in the array such that the interior of a capillary is imaged onto only one pixel. In Sanger-type 4-label DNA sequencing reactions, nucleotide identification (``base calling``) is improved by using two long-pass filters to split fluorescence emission into two emission channels. A binary poly(ethyleneoxide) matrix is used in the electrophoretic separations. 19 figs.

  4. Electronic imaging systems for quantitative electrophoresis of DNA

    International Nuclear Information System (INIS)

    Sutherland, J.C.

    1989-01-01

    Gel electrophoresis is one of the most powerful and widely used methods for the separation of DNA. During the last decade, instruments have been developed that accurately quantitate in digital form the distribution of materials in a gel or on a blot prepared from a gel. In this paper, I review the various physical properties that can be used to quantitate the distribution of DNA on gels or blots and the instrumentation that has been developed to perform these tasks. The emphasis here is on DNA, but much of what is said also applies to RNA, proteins and other molecules. 36 refs

  5. Determination of five nitroimidazole residues in artificial porcine muscle tissue samples by capillary electrophoresis.

    Science.gov (United States)

    Lin, Yingyun; Su, Yan; Liao, Xiulin; Yang, Na; Yang, Xiupei; Choi, Martin M F

    2012-01-15

    A capillary electrophoresis (CE) method with ultraviolet detection has been developed for simultaneous detection and quantification of five nitroimidazoles including benzoylmetronidazole, dimetridazole, metronidazole, ronidazole, and secnidazole in porcine muscles. Nitroimidazoles in samples were extracted by ethyl acetate with subsequent clean-up by a strong cation exchange solid phase extraction column. The clean extracts were subjected to CE separation with optimal experimental conditions: pH 3.0 running buffer containing 25mM sodium phosphate and 0.10mM tetrabutylammonium bromide, 5s hydrodynamic injection at 0.5psi and 28kV separation voltage. The nitroimidazoles could be monitored and detected at 320nm within 18min. The limits of detection were below 1.0μg/kg and limits of quantification were lower than 3.2μg/kg for all nitroimidazoles in the muscle samples. The recoveries and relative standard deviations were 85.4-96.0, 83.5-92.5, 1.3-3.9, and 1.1-4.2%, respectively for the intra-day and inter-day analyses. The proposed CE method has been successfully applied to determine nitroimidazoles in artificial porcine muscle samples with good accuracy and recovery, demonstrating that it has potential for detection and quantification of multi-nitroimidazole residue in real muscle samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Reverse polarity capillary zone electrophoresis analysis of nitrate and nitrite in natural water samples

    Energy Technology Data Exchange (ETDEWEB)

    Metcalf, S.G.

    1998-06-11

    This paper describes the application of reverse polarity capillary zone electrophoresis (RPCE) for rapid and accurate determination of nitrate and nitrite in natural water samples. Using hexamethonium bromide (HMB) as an electroosmotic flow modifier in a borate buffer at pH 9.2, the resolution of nitrate and nitrite was accomplished in less than 3 minutes. RPCE was compared with ion chromatographic (IC) and cadmium reduction flow injection analysis (Cd-FIA) methods which are the two most commonly used standard methods for the analysis of natural water samples for nitrate and nitrite. When compared with the ion chromatographic method for the determination of nitrate and nitrite, RPCE reduced analysis time, decreased detection limits by a factor of 10, cut laboratory wastes by more than two orders of magnitude, and eliminated interferences commonly associated with IC. When compared with the cadmium reduction method, RPCE had the advantage of simultaneous determination of nitrate and nitrite, could be used in the presence of various metallic ions that normally interfere in cadmium reduction, and decreased detection limits by a factor of 10.

  7. Simultaneous determination of isoniazid and p-aminosalicylic acid by capillary electrophoresis using chemiluminescence detection.

    Science.gov (United States)

    Zhang, Xinfeng; Xuan, Yuelan; Sun, Aimin; Lv, Yi; Hou, Xiandeng

    2009-01-01

    It was found that isoniazid (ISO) or p-aminosalicylic acid (PAS) could enhance the chemiluminescence (CL) emission from Cu (II)-luminol-hydrogen peroxide system, and the increased chemiluminescence signals were proportional to their concentrations, respectively. Based on this phenomenon, a chemiluminescence method coupled to capillary electrophoresis (CE) was established for simultaneous determination of ISO and PAS. The CE conditions including running buffer and running voltage were investigated in detail. The effects of the pH of H(2)O(2) solution and the concentrations of luminol, H(2)O(2) and Cu (II) on the CL signal were also investigated carefully. Under the optimized conditions, the analysis could be accomplished within 10 min, with the limits of detection of 0.3 microg mL(-1) for ISO and 1.1 microg mL(-1) for PAS, corresponding to 7.2 and 26.4 pg per injection (24 nL), respectively. Finally, the method was validated by determining the two analytes in pharmaceutical preparation and spiked human serum samples. The results of pharmaceutical tablet analysis were in good agreement with the labeled amounts. The recoveries for ISO and PAS in human serum were in the range of 92-104% and 90-113%, respectively. Copyright 2008 John Wiley & Sons, Ltd.

  8. Calibration of pulsed field gel electrophoresis for measurement of DNA double-strand breaks

    International Nuclear Information System (INIS)

    Ager, D.D.; Dewey, W.C.

    1990-01-01

    Pulsed field gel electrophoresis (PFGE) assay was calibrated for the measurement of X-ray induced DNA double-strand breaks in Chinese hamster ovary (CHO) cells. Calibration was conducted by incorporating [ 125 I] deoxyuridine into DNA, which induces one double-strand break for every disintegration that occurs in frozen cells. Based on the percentage of DNA migrating into the gel, the number of breaks/dalton/Gy was estimated to be (9.3±1.0) x 10 -12 . This value is close to (10 to 12) x 10 -12 determined by neutral filter elution using similar cell lysis procedures at 24 o C and at pH8.0. The estimate is in good agreement with the value of (11.7±2) x 10 -12 breaks/dalton/Gy as measured in Ehrlich ascites tumour cells using the neutral sucrose gradient method (Bloecher 1988), and (6 to 9) x 10 -12 breaks/dalton/Gy as measured in mouse L and Chinese hamster V79 cells using neutral filter elution (Radford and Hodgson 1985). (author)

  9. Determination of the R-enantiomer of valsartan in pharmaceutical formulation by capillary electrophoresis.

    Science.gov (United States)

    Lee, Kyung Ran; Nguyen, NgocVan Thi; Lee, Yong Jae; Choi, Seungho; Kang, Jong Seong; Mar, Woongchon; Kim, Kyeong Ho

    2015-01-01

    Capillary zone electrophoresis was successfully applied to the enantiomeric purity determination of valsartan using acetyl-β-cyclodextrin (A-β-CD) as a chiral selector. Separations were carried out in a 50 µm, 64/56 cm fused-silica capillary. The optimized conditions included 25 mM phosphate buffer, pH 8.0, containing 10 mM A-β-CD as background electrolyte, an applied voltage of +30 kV and a temperature of 30 °C. Ibuprofen was used as an internal standard. The assay was validated for the R-enantiomer of valsartan in the range of 0.05-3.0%. The limit of detection was 0.01%, the limit of quantitation was 0.05%, relative to a concentration of valsartan of 1 mg/ml. Intra-day precision varied between 2.57 and 5.60%. Relative standard deviations of inter-day precision ranged between 4.46 and 6.76% for peak area ratio. The percentage recovery of the R-enantiomer of valsartan ranged between 97.0 and 99.6% in valsartan product. The assay was applied to the determination of the chiral purity of valsartan tablets and R-enantiomer of valsartan was found as an impurity.

  10. Separation of thiosulfate and the polythionates in gold thiosulfate leach solutions by capillary electrophoresis.

    Science.gov (United States)

    O'Reilly, John W; Dicinoski, Greg W; Miura, Yasuyuki; Haddad, Paul R

    2003-06-01

    A technique for the separation of thiosulfate (S(2)O(3) (2-)), polythionates (S(x)O(6) (2-), x = 3 to 5) and the gold(I) thiosulfate complex (Au(S(2)O(3))(2) (3-)) using capillary electrophoresis with simultaneous UV detection at 195 and 214 nm is presented. The five species were separated in under 3 min with a total analysis time of 8 min, using an electrolyte containing 25 mM 2,2-bis(hydroxymethyl)-2,2',2"-nitrilotriethanol (bis-tris) adjusted to pH 6.0 with sulfuric acid and an applied voltage of -30 kV. While the gold(I) thiosulfate complex could be separated from the other analytes of interest under these conditions, the quantification of this complex was not possible due to inconsistent peak areas and peak splitting effects induced by the sulfur-oxygen species in the leach matrix. Detection limits calculated for 3s pressure injection at 50 mbar ranged between 0.5-2 microM. The method was linear over the ranges 40-8000, 10-2000, 10-2000, and 5-2000 microM for thiosulfate, trithionate, tetrathionate, and pentathionate, respectively. The technique was applied successfully to leach liquors containing 0.5 M ammonium thiosulfate, 2 M ammonia, 0.05 M copper sulfate and 20% w/v gold ore, diluted 1:100 prior to analysis.

  11. Simultaneous determination of rifabutin and human serum albumin in pharmaceutical formulations by capillary electrophoresis.

    Science.gov (United States)

    Ermolenko, Yu; Anshakova, A; Osipova, N; Kamentsev, M; Maksimenko, O; Balabanyan, V; Gelperina, S

    Capillary zone electrophoresis (CZE) was used for determination of rifabutin (RFB), an anti-tuberculosis antibiotic drug, in various pharmaceutical formulations. Apart from that, simultaneous determination of RFB and human serum albumin (HSA) was performed. Electrophoretic behaviour of RFB was examined at various pH levels. CE conditions: a quartz capillary tube (internal diameter 75mm, effective length 50cm, total length 60cm), the capillary temperature was 25°С, the voltage applied to the capillary tube was +20kV, the UV detection wavelength was 214nm, hydrodynamic injection of the sample was performed at 30mbar for 5s, tetraborate buffer solution (0.01М, рН9.2). The obtained results are characterized by high efficiency (number of theoretical plates up to 260,000) and sufficient sensitivity (LOQ starting from 0.02μg/ml for RFB). The obtained data are in good accord with both HPLC results (for RFB) and spectrophotometry (for HSA). Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Fast Separation and Determination of Flavonoids in Honey Samples by Capillary Zone Electrophoresis

    Directory of Open Access Journals (Sweden)

    Jian-Qiu Tu

    2017-03-01

    Full Text Available Flavonoids have crucial applications in the biological and physiological fields. Honey, as an important sweet food made by bees, is rich in flavonoids. In this paper, the analytical method for flavonoids determination in different sorts of honey from different geographical locations was developed by capillary zone electrophoresis with direct ultraviolet detection. With a running buffer (borate, 20 mmol l−1 at pH of 8.4, four typical flavonoids, rutin, quercetin, kaempferol and myricetin, were separated in five minutes under a applied potential of 25 kV. A linear relationship within the range of 2.0 – 500 mg l−1 was found for these four kinds of flavonoids. Moreover, the detection limits ranged from 1.17 to 1.76 mg l−1. The recoveries lie in the range between 80 % – 107 %. The developed method was then used in the separation and determination of flavonoids in real honey samples collected from 12 geographical locations in the Henan Province of China. Rutin was detected in six, and quercetin in eight honey samples, which may be the markers for the identification of honey from different geographical origins.

  13. Separation of arsenic species by capillary electrophoresis with sample-stacking techniques

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zu Liang; Naidu, Ravendra [Adelaide Laboratory, CSIRO Land and Water, PMB2, 5064, Glen Osmond, SA (Australia); Lin, Jin-Ming [Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, 100085, Beijing (China)

    2003-03-01

    A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO{sub 2}{sup 2-}, AsO{sub 4}{sup 2-}, and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L{sup -1} sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl{sup -}, NO{sub 2}{sup -}, NO{sub 3}{sup -} and SO{sub 4}{sup 2-}) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 {mu}mol L{sup -1} of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water. (orig.)

  14. Analysis of compositional monosaccharides in fungus polysaccharides by capillary zone electrophoresis.

    Science.gov (United States)

    Hu, Yuanyuan; Wang, Tong; Yang, Xingbin; Zhao, Yan

    2014-02-15

    A rapid analytical method of capillary zone electrophoresis (CZE) was established for the simultaneous separation and determination of 10 monosaccharides (aldoses and uronic acids). The monosaccharides were labeled with 1-phenyl-3-methyl-5-pyrazolone (PMP), and subsequently separated using an uncoated capillary (50 μm i.d. × 58.5 cm) and detected by UV at 245 nm with pH 11.0, 175 mM borate buffer at voltage 20 kV and capillary temperature 25 °C by CZE. The 10 PMP-labeled monosaccharides were rapidly baseline separated within 20 min. The optimized CZE method was successfully applied to the simultaneous separation and identification of the monosaccharide composition in Termitomyces albuminosus polysaccharides (TAPs) and Panus giganteus polysaccharides (PGPs). The quantitative recovery of the component monosaccharides in the fungus polysaccharides was in the range of 92.0-101.0% and the CV value was lower than 3.5%. The results demonstrate that the proposed CZE method is precise and practical for the monosaccharide analysis of fungus polysaccharides. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Quantitative Determination of Lercanidipine Enantiomers in Commercial Formulations by Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Luciana Pereira Lourenço

    2015-01-01

    Full Text Available An enantioselective method based on capillary electrophoresis (CE using cyclodextrin (CD as chiral selector was developed and validated for determination of lercanidipine (LER enantiomers, a drug calcium channel blocker which exerts antihypertensive effects of long duration, in a pharmaceutical formulation. Optimum separation of LER enantiomers was obtained on a 50 cm × 50 μm id capillary using a sodium acetate buffer solution 200 mmol/L pH 4.0 containing 10 mmol/L of 2,3,6-o-methyl-β-cyclodextrin (TM-β-CD as background electrolyte. The capillary temperature and voltage were 15°C and 25 kV, respectively, hydrodynamic injection and detection at 237 nm. Linearity was obtained in the range 12.5–100 μg/mL for both enantiomers (r≥0.995. The RSD (% and relative errors (E, % obtained in precision and accuracy studies (intraday and interday were lower than 5%. After validation, the method was applied to quantify the enantiomers of LER in commercial tablets and the results were satisfactory in terms of accuracy and precision, both less than 5%. Therefore, this method was found to be appropriate for enantioselective quality control of LER enantiomers in pharmaceutical formulations.

  16. The protective effect of caffeine on DNA photosensitive damage: a gel electrophoresis

    International Nuclear Information System (INIS)

    Huang Liping; Ma Jianhua

    2009-01-01

    Agarose gel electrophoresis was performed to study interaction effect of caffeine on photosensitive injury of DNA caused by anthraquinone-2-sulphonic acid disodium (AQS), a model compound of strong photosensitizer, under 254 nm or 365nm UV irradiation Photosensitive injury of DNA induced by AQS under deoxidized condition was used as control. The results show that caffeine may resist effectively the injury effect of photosensitive damage and strong UV irradiation on DNA. The effects depend on the caffeine and AQS concentration, and irradiation time. Caffeine in concentration of 0.01-3.0 μg/μL, may prevent DNA from damage induced by UV light, but caffeine in concentration of >5.0 μg/μL accelerates the DNA damage. In particular, in the aqueous solution system of DNA, caffeine and AQS, at pH 6.25-7.35, the caffeine in concentration of 2.5-4.50 μg/μL may resist the photosensitive injury of DNA caused by AQS under the deoxidized condition and exposure by 254 nm UV for 10 min. And caffeine in concentration of 5 μg/μL would present a synergetic effect on the photosensitive injury of DNA. Possible molecular mechanism also is discussed. (authors)

  17. Methoxypropylamino β-cyclodextrin clicked AC regioisomer for enantioseparations in capillary electrophoresis

    International Nuclear Information System (INIS)

    Zhou, Jie; Wang, Yiying; Liu, Yun; Tang, Jian; Tang, Weihua

    2015-01-01

    Highlights: In this paper, we demonstrate: • The click synthesis of a AC regioisomer cationic cyclodextrin (CD) as chiral selector. • The good enantioselectivities (chiral resolution over 5) for acidic racemates. • The strong chiral recognition of new CD by NMR study. • Baseline enantioseparation of some acidic racemates at CD of 0.5 mM. - Abstract: In this work, a novel methoxypropylamino β-cyclodextrin (β-CD) clicked AC regioisomer, 6 A -4-hydroxyethyl-1,2,3-triazolyl-6 C -3-methoxypropylamino β-cyclodextrin (HETz-MPrAMCD), was synthesized via nucleophilic addition and click chemistry. The chiral separation ability of this AC regioisomer cationic CD was evaluated toward 7 ampholytic and 13 acidic racemates by capillary electrophoresis. Dependence of enantioselectivity and resolution on buffer pH (5.5–8.0) and chiral selector concentration (0.5–7.5 mM) was investigated. Enantioselectivities (α ≥ 1.05) could be achieved for most analytes under optimal conditions except dansyl-DL-noreleucine and dansyl-DL-serine. The highest resolutions for 2-chloromandelic acid p-hydroxymandelic acid were 15.6 and 9.7 respectively. The inclusion complexation between HETz-MPrAMCD and each 3-phenyllactic acid enantiomer was also revealed with nuclear magnetic resonance study

  18. Methoxypropylamino β-cyclodextrin clicked AC regioisomer for enantioseparations in capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jie; Wang, Yiying; Liu, Yun; Tang, Jian; Tang, Weihua, E-mail: whtang@mail.njust.edu.cn

    2015-04-08

    Highlights: In this paper, we demonstrate: • The click synthesis of a AC regioisomer cationic cyclodextrin (CD) as chiral selector. • The good enantioselectivities (chiral resolution over 5) for acidic racemates. • The strong chiral recognition of new CD by NMR study. • Baseline enantioseparation of some acidic racemates at CD of 0.5 mM. - Abstract: In this work, a novel methoxypropylamino β-cyclodextrin (β-CD) clicked AC regioisomer, 6{sup A}-4-hydroxyethyl-1,2,3-triazolyl-6{sup C}-3-methoxypropylamino β-cyclodextrin (HETz-MPrAMCD), was synthesized via nucleophilic addition and click chemistry. The chiral separation ability of this AC regioisomer cationic CD was evaluated toward 7 ampholytic and 13 acidic racemates by capillary electrophoresis. Dependence of enantioselectivity and resolution on buffer pH (5.5–8.0) and chiral selector concentration (0.5–7.5 mM) was investigated. Enantioselectivities (α ≥ 1.05) could be achieved for most analytes under optimal conditions except dansyl-DL-noreleucine and dansyl-DL-serine. The highest resolutions for 2-chloromandelic acid p-hydroxymandelic acid were 15.6 and 9.7 respectively. The inclusion complexation between HETz-MPrAMCD and each 3-phenyllactic acid enantiomer was also revealed with nuclear magnetic resonance study.

  19. Development of a fast capillary electrophoresis method for determination of carbohydrates in honey samples.

    Science.gov (United States)

    Rizelio, Viviane Maria; Tenfen, Laura; da Silveira, Roberta; Gonzaga, Luciano Valdemiro; Costa, Ana Carolina Oliveira; Fett, Roseane

    2012-05-15

    In this study, the determination of fructose, glucose and sucrose by capillary electrophoresis (CE) was investigated. The tendency of the analyte to undergo electromigration dispersion and the buffer capacity were evaluated using the Peakmaster(®) software and considered in the optimization of the background electrolyte, which was composed of 20 mmol L(-1) sorbic acid, 0.2 mmol L(-1) CTAB and 40 mmol L(-1) NaOH at pH 12.2. Under optimal CE conditions, the separation of the substances investigated was achieved in less than 2 min. The detection limits for the three analytes were in the range of 0.022 and 0.029 g L(-1) and precision measurements within 0.62-4.69% were achieved. The proposed methodology was applied in the quantitative analysis by direct injection of in honey samples to determine the main sugars presents. The samples were previously dissolved in deionized water and filtered with no other sample treatment. The mean values for fructose, glucose and sucrose were in the ranges of 33.65-45.46 g 100g(-1), 24.63-35.06 g 100g(-1) and <0.22-1.32 g 100g(-1), respectively. The good analytical performance of the method makes it suitable for implementation in food laboratories for the routine analysis of honey samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Simultaneous analysis of saturated and unsaturated fatty acids present in pequi fruits by capillary electrophoresis

    Directory of Open Access Journals (Sweden)

    Patrícia M. de Castro Barra

    2013-01-01

    Full Text Available In the current study, an alternative method has been proposed for simultaneous analysis of palmitic, stearic, oleic, linoleic, and linolenic acids by capillary zone electrophoresis (CZE using indirect detection. The background electrolyte (BGE used for the analysis of these fatty acids (FAs consisted of 15.0 mmol L−1 NaH2PO4/Na2HPO4 at pH 6.86, 4.0 mmol L−1 SDBS, 8.3 mmol L−1 Brij 35, 45% v/v acetonitrile (can, and 2.1% n-octanol. The FAs quantification of FAs was performed using a response factor approach, which provided a high analytical throughput for the real sample. The CZE method, which was applied successfully for the analysis of pequi pulp, has advantages such as short analysis time, absence of lipid fraction extraction and derivatization steps, and no significant difference in the 95% confidence intervals for FA quantification results, compared to the gas chromatography official method (AOCS Ce 1h-05.

  1. Determination of gentisin, isogentisin, and amarogentin in Gentiana lutea L. by capillary electrophoresis.

    Science.gov (United States)

    Citová, Ivana; Ganzera, Markus; Stuppner, Hermann; Solich, Petr

    2008-01-01

    A novel, fast, and simple capillary electrophoresis method has been developed for the analysis of gentisin, isogentisin, and amarogentin in roots of Gentiana lutea (yellow gentian), an herb traditionally used as gastric stimulant. Gentisin and isogentisin are xanthones showing potent inhibition of monoamine oxidase type A and B, amarogentin represents one of the bitter principles of Gentiana, responsible for its gastric-roborant effects. Optimal CE-separation conditions comprise a 100 mM sodium tetraborate buffer of pH 9.3, containing 10 mM beta-cyclodextrin as additive; optimum temperature and applied voltage were found to be 30 degrees C and 25 kV, respectively. Direct diode array detection at 260 nm (gentisin, isogentisin) and 242 nm (amarogentin) was performed, and the required analysis time was only 11 min. The developed method was validated for linearity, sensitivity, precision, and accuracy, and utilized to assay several commercially available G. lutea samples. Quantitative data obtained with the developed CE method are compared with HPLC results, and the advantages of each approach are discussed.

  2. A rapid sample screening method for authenticity control of whiskey using capillary electrophoresis with online preconcentration.

    Science.gov (United States)

    Heller, Melina; Vitali, Luciano; Oliveira, Marcone Augusto Leal; Costa, Ana Carolina O; Micke, Gustavo Amadeu

    2011-07-13

    The present study aimed to develop a methodology using capillary electrophoresis for the determination of sinapaldehyde, syringaldehyde, coniferaldehyde, and vanillin in whiskey samples. The main objective was to obtain a screening method to differentiate authentic samples from seized samples suspected of being false using the phenolic aldehydes as chemical markers. The optimized background electrolyte was composed of 20 mmol L(-1) sodium tetraborate with 10% MeOH at pH 9.3. The study examined two kinds of sample stacking, using a long-end injection mode: normal sample stacking (NSM) and sample stacking with matrix removal (SWMR). In SWMR, the optimized injection time of the samples was 42 s (SWMR42); at this time, no matrix effects were observed. Values of r were >0.99 for the both methods. The LOD and LOQ were better than 100 and 330 mg mL(-1) for NSM and better than 22 and 73 mg L(-1) for SWMR. The CE-UV reliability in the aldehyde analysis in the real sample was compared statistically with LC-MS/MS methodology, and no significant differences were found, with a 95% confidence interval between the methodologies.

  3. Reverse polarity capillary zone electrophoresis analysis of nitrate and nitrite in natural water samples

    International Nuclear Information System (INIS)

    Metcalf, S.G.

    1998-01-01

    This paper describes the application of reverse polarity capillary zone electrophoresis (RPCE) for rapid and accurate determination of nitrate and nitrite in natural water samples. Using hexamethonium bromide (HMB) as an electroosmotic flow modifier in a borate buffer at pH 9.2, the resolution of nitrate and nitrite was accomplished in less than 3 minutes. RPCE was compared with ion chromatographic (IC) and cadmium reduction flow injection analysis (Cd-FIA) methods which are the two most commonly used standard methods for the analysis of natural water samples for nitrate and nitrite. When compared with the ion chromatographic method for the determination of nitrate and nitrite, RPCE reduced analysis time, decreased detection limits by a factor of 10, cut laboratory wastes by more than two orders of magnitude, and eliminated interferences commonly associated with IC. When compared with the cadmium reduction method, RPCE had the advantage of simultaneous determination of nitrate and nitrite, could be used in the presence of various metallic ions that normally interfere in cadmium reduction, and decreased detection limits by a factor of 10

  4. Quantitative analysis of flavonoids and phenolic acid in Coreopsis tinctoria Nutt. by capillary zone electrophoresis.

    Science.gov (United States)

    Deng, Yong; Lam, Shing-Chung; Zhao, Jing; Li, Shao-Ping

    2017-10-01

    Capillary zone electrophoresis was developed for the simultaneous determination of five flavonoids and one phenolic acid, including taxifolin-7-O-glucoside, flavanomarein, quercetagetin-7-O-glucoside, okanin 4'-O-glucoside, okanin, and chlorogenic acid, in different parts and origins of Coreopsis tinctoria and its related species. Effects of acidity, running-buffer concentration, and modifier concentration were investigated to determine the optimum conditions for analyte determination. Analysis was performed within 18 min by using 50 mM borax buffer containing 15% acetonitrile as a modifier (pH 9.0) at 25 kV and 25°C. Hyperoside was used as internal standard for quantification. The method was accurate, simple, and repeatable, and was successfully applied to the analysis in 13 samples with satisfactory assay results. Results showed that C. tinctoria obviously differed from the related flower tea materials, "Hangju" and "Gongju". The parts (flowers, buds, seeds, stems, and leaves) of C. tinctoria also varied among one another. This study can serve as a foundation for the quality control and pharmacological evaluation of different parts of C. tinctoria and its related species. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Optimization of capillary zone electrophoresis for charge heterogeneity testing of biopharmaceuticals using enhanced method development principles.

    Science.gov (United States)

    Moritz, Bernd; Locatelli, Valentina; Niess, Michele; Bathke, Andrea; Kiessig, Steffen; Entler, Barbara; Finkler, Christof; Wegele, Harald; Stracke, Jan

    2017-12-01

    CZE is a well-established technique for charge heterogeneity testing of biopharmaceuticals. It is based on the differences between the ratios of net charge and hydrodynamic radius. In an extensive intercompany study, it was recently shown that CZE is very robust and can be easily implemented in labs that did not perform it before. However, individual characteristics of some examined proteins resulted in suboptimal resolution. Therefore, enhanced method development principles were applied here to investigate possibilities for further method optimization. For this purpose, a high number of different method parameters was evaluated with the aim to improve CZE separation. For the relevant parameters, design of experiments (DoE) models were generated and optimized in several ways for different sets of responses like resolution, peak width and number of peaks. In spite of product specific DoE optimization it was found that the resulting combination of optimized parameters did result in significant improvement of separation for 13 out of 16 different antibodies and other molecule formats. These results clearly demonstrate generic applicability of the optimized CZE method. Adaptation to individual molecular properties may sometimes still be required in order to achieve optimal separation but the set screws discussed in this study [mainly pH, identity of the polymer additive (HPC versus HPMC) and the concentrations of additives like acetonitrile, butanolamine and TETA] are expected to significantly reduce the effort for specific optimization. 2017 The Authors. Electrophoresis published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Microchip electrophoresis with electrochemical detection for the determination of analytes in the dopamine metabolic pathway

    Science.gov (United States)

    Saylor, Rachel A.; Reid, Erin A.; Lunte, Susan M.

    2016-01-01

    A method for the separation and detection of analytes in the dopamine metabolic pathway was developed using microchip electrophoresis with electrochemical detection. The microchip consisted of a 5 cm PDMS separation channel in a simple-t configuration. Analytes in the dopamine metabolic pathway were separated using a background electrolyte composed of 15 mM phosphate at pH 7.4, 15 mM SDS, and 2.5 mM boric acid. Two different microchip substrates using different electrode materials were compared for the analysis: a PDMS/PDMS device with a carbon fiber electrode and a PDMS/glass hybrid device with a pyrolyzed photoresist film carbon electrode. While the PDMS/PDMS device generated high separation efficiencies and good resolution, more reproducible migration times were obtained with the PDMS/glass hybrid device, making it a better choice for biological applications. Lastly, the optimized method was used to monitor L-DOPA metabolism in a rat brain slice. PMID:25958983

  7. Simultaneous separation and determination of four uncaria alkaloids by capillary electrophoresis using dual cyclodextrin system.

    Science.gov (United States)

    Li, Lou; Xu, Liying; Chen, Meng; Zhang, Guangbin; Zhang, Hongfen; Chen, Anjia

    2017-07-15

    The purpose of this study was to develop a simple, quick and precise capillary zone electrophoresis method (CZE) for the separation and determination of uncaria alkaloids using dual cyclodextrins as additives for the separation. The four analytes were baseline separated within 15min at the applied voltage of 15kV with a running buffer (pH 5.7) consisting of 40.0mM phosphate buffer, 161.7mM 2-hydroxypropyl-β-cyclodextrin (HP-β-CD) and 2.21mM mono-(6-ethylenediamine-6-deoxy)-β-cyclodextrin (ED-β-CD). Under the optimum conditions, a good linearity was achieved with correlation coefficients from 0.9989 to 0.9992. The detection limits and the quantitation limits ranged from 0.63 to 0.98μg/mL and from 2.08 to 3.28μg/mL, respectively. Excellent accuracy and precision were obtained. Recoveries of the analytes varied from 97.1 to 103.2%. This method was suitable for the quantitative determination of these alkaloids in the stem with hook of Uncaria rhynchophylla and the formulations of Uncaria rhynchophylla. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Establishment of the optimum two-dimensional electrophoresis system of ovine ovarian tissue.

    Science.gov (United States)

    Jia, J L; Zhang, L P; Wu, J P; Wang, J; Ding, Q

    2014-08-26

    Lambing performance of sheep is the most important economic trait and is regarded as a critic factoring affecting the productivity in sheep industry. Ovary plays the most roles in lambing trait. To establish the optimum two-dimensional electrophoresis system (2-DE) of ovine ovarian tissue, the common protein extraction methods of animal tissue (trichloroacetic acid/acetone precipitation and direct schizolysis methods) were used to extract ovine ovarian protein, and 17-cm nonlinear immobilized PH 3-10 gradient strips were used for 2-DE. The sample handling, loading quantity of the protein sample, and isoelectric focusing (IEF) steps were manipulated and optimized in this study. The results indicate that the direct schizolysis III method, a 200-μg loading quantity of the protein sample, and IEF steps II (20°C active hydration, 14 h→500 V, 1 h→1000 V 1 h→1000-9000 V, 6 h→80,000 VH→500 V 24 h) are optimal for 2-DE analysis of ovine ovarian tissue. Therefore, ovine ovarian tissue proteomics 2-DE was preliminarily established by the optimized conditions in this study; meanwhile, the conditions identified herein could provide a reference for ovarian sample preparation and 2-DE using tissues from other animals.

  9. Contribution of capillary electrophoresis to an integrated vision of humic substances size and charge characterizations

    International Nuclear Information System (INIS)

    D'Orlye, Fanny; Reiller, Pascal E.

    2014-01-01

    The physicochemical properties of three different humic substances (HS) are probed using capillary zone electrophoresis in alkaline carbonate buffers, pH 10. Special attention is drawn to the impact of the electrolyte ionic strength and counter-ion nature, chosen within the alkali-metal series, on HS electrophoretic mobility. Taylor-Aris dispersion analysis provides insights into the hydrodynamic radius (R-H) distributions of HS. The smallest characterized entities are of nano-metric dimensions, showing neither ionic strength- nor alkali-metal-induced aggregation. These results are compared with the entities evidenced in dynamic light scattering measurements, the size of which is two order of magnitude higher, ca. 100 nm. The extended Onsager model provides a reasonable description of measured electrophoretic mobilities in the ionic strength range 1-50 mM, thus allowing the estimation of limiting mobilities and ionic charge numbers for the different HS samples. An unexpected HS electrophoretic mobility increase (in absolute value) is observed in the order Li + ≤ Na + ≤ K + ≤ Cs + and discussed either in terms of retarding forces or in terms of ion-ion interactions. (authors)

  10. Characterization and identification of proteases secreted by Aspergillus fumigatus using free flow electrophoresis and MS.

    Science.gov (United States)

    Neustadt, Madlen; Costina, Victor; Kupfahl, Claudio; Buchheidt, Dieter; Eckerskorn, Christoph; Neumaier, Michael; Findeisen, Peter

    2009-06-01

    Early diagnosis of life-threatening invasive aspergillosis in neutropenic patients remains challenging because current laboratory methods have limited diagnostic sensitivity and/or specificity. Aspergillus species are known to secrete various pathogenetically relevant proteases and the monitoring of their protease activity in serum specimens might serve as a new diagnostic approach.For the characterization and identification of secreted proteases, the culture supernatant of Aspergillus fumigatus was fractionated using free flow electrophoresis (Becton Dickinson). Protease activity of separated fractions was measured using fluorescently labeled reporter peptides. Fractions were also co-incubated in parallel with various protease inhibitors that specifically inhibit a distinct class of proteases e.g. metallo- or cysteine-proteases. Those fractions with high protease activity were further subjected to LC-MS/MS analysis for protease identification. The highest protease activity was measured in fractions with an acidic pH range. The results of the 'inhibitor-panel' gave a clear indication that it is mainly metallo- and serine-proteases that are involved in the degradation of reporter peptides. Furthermore, several proteases were identified that facilitate the optimization of reporter peptides for functional protease profiling as a diagnostic tool for invasive aspergillosis.

  11. Simultaneous determination of active ingredients in Erigeron breviscapus (Vant.) Hand-Mazz. by capillary electrophoresis with electrochemical detection.

    Science.gov (United States)

    Chu, Qingcui; Wu, Ting; Fu, Liang; Ye, Jiannong

    2005-03-09

    A high-performance capillary electrophoresis (CE) with electrochemical detection (ED) method was developed for the determination of the pharmacologically active ingredients in Erigeron breviscapus (Vant.) Hand-Mazz. and its extract phytopharmaceuticals in this work. Under the optimum conditions, nine analytes, baicalein, naringenin, scopoletin, kaempferol, apigenin, scutellarin, luteolin, caffeic acid and protocatechuic acid were separated within 24 min in a borax buffer (pH 8.7). Notably, excellent linearity was obtained over two orders of magnitude with detection limits (S/N=3) ranged from 1.0 x 10(-7) g/mL to 5.6 x 10(-7) g/mL for all nine analytes. This method was successfully used in the analysis of E. breviscapus (Vant.) Hand-Mazz. and its phytopharmaceuticals with a relatively simple extraction procedure, and the assay results were satisfactory.

  12. Separation of oligopeptides, nucleobases, nucleosides and nucleotides using capillary electrophoresis/electrochromatography with sol-gel modified inner capillary wall.

    Science.gov (United States)

    Svobodová, Jana; Kofroňová, Olga; Benada, Oldřich; Král, Vladimír; Mikšík, Ivan

    2017-09-29

    The aim of this article is to study the modification of an inner capillary wall with sol-gel coating (pure silica sol-gel or silica sol-gel containing porphyrin-brucine conjugate) and determine its influence on the separation process using capillary electrophoresis/electrochromatography method. After modification of the inner capillary surface the separation of analytes was performed using two different phosphate buffers (pH 2.5 and 9.0) and finally the changes in electrophoretic mobilities of various samples were calculated. To confirm that the modification of the inner capillary surface was successful, the parts of the inner surfaces of capillaries were observed using scanning electron microscopy. The analytes used as testing samples were oligopeptides, nucleosides, nucleobases and finally nucleotides. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Analysis and confirmation of synthetic anorexics in adulterated traditional Chinese medicines by high-performance capillary electrophoresis.

    Science.gov (United States)

    Ku, Y R; Chang, Y S; Wen, K C; Ho, L K

    1999-07-02

    Six synthetic anorexics, clobenzorex, diethylpropion, fenfluramine, methamphetamine, phenylpropanolamine and phentermine, which can be found as adulterants in traditional Chinese medicines were assayed simultaneously by high-performance capillary electrophoresis. The electrolyte was a buffer solution containing 120 mM phosphate buffer (NaH2PO4/H3PO4, pH 2.0) and 15% acetonitrile. Applied voltage was 16 kV and temperature was 30 degrees C. Fluoren-2,7-diammonium chloride was used as an internal standard and detector set at 200 nm. The recoveries of the synthetic anorexic adulterants in traditional Chinese medicinal formula using C8-SCX mixed solid-phase extraction were studied. Several traditional Chinese medicinal powders obtained from clinics were also studied by the above HPCE method and confirmed by GC-MS. Clobenzorex, diethylpropion and fenfluramine were found and determine in these samples.

  14. Fast separation of enantiomers by capillary electrophoresis using a combination of two capillaries with different internal diameters.

    Science.gov (United States)

    Šebestová, Andrea; Petr, Jan

    2017-12-01

    The combination of capillaries with different internal diameters was used to accelerate the separation of enantiomers in capillary electrophoresis. Separation of R,S-1,1'-binaphthalene-2,2'-diyl hydrogen phosphate using isopropyl derivative of cyclofructan 6 was studied as a model system. The best separation conditions included 500 mM sodium borate pH 9.5 with 60 mM concentration of the chiral selector. Separation lasted approx. 1.5 min using the combination of 50 and 100 μm id capillaries of 9.7 cm and 22.9 cm, respectively. It allowed approx. 12-fold acceleration in comparison to the traditional long-end separation mainly due to the higher electroosmotic flow generated in the connected capillaries. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Characterization of sup(99m)Tc/sup(99)Tc-hydroxycarboxylic acid chelates by high voltage electrophoresis without supporting material

    International Nuclear Information System (INIS)

    Hoffmann, I.; Muenze, R.; Dreyer, I.; Dreyer, R.

    1982-01-01

    Ion mobilities of different sup(99m)Tc- and 99 Tc chelates prepared by reduction of pertechnetate by Sn(II) in the presence of citric, malic, tartaric, gluconic, and α-hydroxyisobutyric acid as ligands have been measured by means of electrophoresis without supporting material. All the chelates investigated proved to be anions in the pH range of 2-7. Both the Tc(V)- and Tc(IV) compounds with the same ligand including the sup(99m)Tc preparation show identical ion mobilities and dissociation characteristics. (author)

  16. Growth rate analysis and protein identification of Kappaphycus alvarezii (Rhodophyta, Gigartinales under pH induced stress culture

    Directory of Open Access Journals (Sweden)

    Mian Zi Tee

    2015-11-01

    Full Text Available Environmental pH is one of the factors contributing to abiotic stress which in turn influences the growth and development of macroalgae. This study was conducted in order to assess the growth and physiological changes in Kappaphycus alvarezii under different pH conditions: pHs 6, ∼8.4 (control and 9. K. alvarezii explants exhibited a difference in the daily growth rate (DGR among the different pH treatments (p ≤ 0.05. The highest DGR was observed in control culture with pH ∼8.4 followed by alkaline (pH 9 and acidic (pH 6 induced stress cultures. Protein expression profile was generated from different pH induced K. alvarezii cultures using sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE followed by protein identification and analysis using matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF-MS and Mascot software. Ribulose bisphosphate carboxylase (Rubisco large chain was identified to be up-regulated under acidic (pH 6 condition during the second and fourth week of culture. The findings indicated that Rubisco can be employed as a biomarker for pH induced abiotic stress. Further study on the association between the expression levels of Rubisco large chain and their underlying mechanisms under pH stress conditions is recommended.

  17. Rapid monitoring of autolysis process of proteases by capillary electrophoresis.

    Science.gov (United States)

    Chen, Xiu-Lan; Shun, Cai-Yun; Zhang, Yu-Zhong; Gao, Pei-Ji

    2003-10-01

    A protease, MCP-01, produced by a deep-sea psychrotrophic strain of Pseudoaltermonas sp. SM9913 was purified and its autolysis reaction at 20 degrees C-50 degrees C was monitored by capillary electrophoresis. Capillary electrophoresis provides a rapid assay because the degree and state of autolysis of protease MCP-01 could be observed within 6 min. The autolysis rate increased as the temperature rose in the tested range. After 30 min incubation at 30 degrees C, 77% of MCP-01 autolyzed into peptides. However, its activity for the hydrolysis of casein was reduced by only 4%. The rate of loss of activity of MCP-01 was thus slower than that of autolysis of MCP-01 at 30 degrees C. Similar results were obtained when MCP-01 was incubated at 20 degrees C, 40 degrees C and 50 degrees C. Large peptides produced by autolysis of MCP-01 therefore still have catalytic activity. When these large peptides autolyzed further into smaller peptides, the enzyme conformation that retained its catalytic activity was destroyed and activity was lost.

  18. Tilted hexagonal post arrays: DNA electrophoresis in anisotropic media.

    Science.gov (United States)

    Chen, Zhen; Dorfman, Kevin D

    2014-02-01

    Using Brownian dynamics simulations, we show that DNA electrophoresis in a hexagonal array of micron-sized posts changes qualitatively when the applied electric field vector is not coincident with the lattice vectors of the array. DNA electrophoresis in such "tilted" post arrays is superior to the standard "un-tilted" approach; while the time required to achieve a resolution of unity in a tilted post array is similar to an un-tilted array at a low-electric field strengths, this time (i) decreases exponentially with electric field strength in a tilted array and (ii) increases exponentially with electric field strength in an un-tilted array. Although the DNA dynamics in a post array are complicated, the electrophoretic mobility results indicate that the "free path," i.e. the average distance of ballistic trajectories of point-sized particles launched from random positions in the unit cell until they intersect the next post, is a useful proxy for the detailed DNA trajectories. The analysis of the free path reveals a fundamental connection between anisotropy of the medium and DNA transport therein that goes beyond simply improving the separation device. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Startup of electrophoresis in a suspension of colloidal spheres.

    Science.gov (United States)

    Chiang, Chia C; Keh, Huan J

    2015-12-01

    The transient electrophoretic response of a homogeneous suspension of spherical particles to the step application of an electric field is analyzed. The electric double layer encompassing each particle is assumed to be thin but finite, and the effect of dynamic electroosmosis within it is incorporated. The momentum equation for the fluid outside the double layers is solved through the use of a unit cell model. Closed-form formulas for the time-evolving electrophoretic and settling velocities of the particles in the Laplace transform are obtained in terms of the electrokinetic radius, relative mass density, and volume fraction of the particles. The time scale for the development of electrophoresis and sedimentation is significantly smaller for a suspension with a higher particle volume fraction or a smaller particle-to-fluid density ratio, and the electrophoretic mobility at any instant increases with an increase in the electrokinetic particle radius. The transient electrophoretic mobility is a decreasing function of the particle volume fraction if the particle-to-fluid density ratio is relatively small, but it may increase with an increase in the particle volume fraction if this density ratio is relatively large. The particle interaction effect in a suspension on the transient electrophoresis is much weaker than that on the transient sedimentation of the particles. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Acetic acid denaturing pulsed field capillary electrophoresis for RNA separation.

    Science.gov (United States)

    Li, Zhenqing; Dou, Xiaoming; Ni, Yi; Sumitomo, Keiko; Yamaguchi, Yoshinori

    2010-10-01

    Based on our previous work of in-capillary denaturing polymer electrophoresis, we present a study of RNA molecular separation up to 6.0 kilo nucleotide by pulsed field CE. This is the first systematic investigation of electrophoresis of a larger molecular mass RNA in linear hydroxyethylcellulose (HEC) under pulsed field conditions. The parameters that may influence the separation performance, e.g. gel polymer concentration, modulation depth and pulse frequency, are analyzed in terms of resolution and mobility. For denaturing and separating RNA in the capillary simultaneously, 2 M acetic acid was added into the HEC polymer to serve as separation buffer. Result shows that (i) in pulsed field conditions, RNA separation can be achieved in a wide range of concentration of HEC polymer, and RNA fragments between 0.3 and 0.6 kilo nucleotide are sensitive to the polymer concentration; (ii) under certain pulsed field conditions, RNA fragments move linearly as the modulation depth increases; (iii) 12.5 Hz is the resonance frequency for RNA reorientation time and applied frequency.

  1. High lane density slab-gel electrophoresis using micromachined instrumentation.

    Science.gov (United States)

    Papautsky, I; Mohanty, S; Weiss, R; Frazier, A B

    2001-10-01

    In this paper, micromachined pipette arrays (MPAs) and microcombs were studied as a means of enabling high lane density gel electrophoresis. The MPA provide a miniaturized format to interface sub-microliter volumes of samples between macroscale sample preparation formats and microscale biochemical analysis systems. The microcombs provide a means of creating sample loading wells in the gel material on the same center-to-center spacing as the MPAs. Together, the two micromachined instruments provide an alternative to current combs and pipetting technologies used for creating sample loading wells and sample delivery in gel electrophoresis systems. Using three designs for the microcomb-MPA pair, center-to-center spacings of 1.0 mm, 500 microm, and 250 microm are studied. The results demonstrate an approximate 10-fold increase in lane density and a 10-fold reduction in sample size from 5 microL to 500 pL. As a result, the number of theoretical plates has increased 2.5-fold, while system resolution has increased 1.5-fold over the conventional agarose gel systems. An examination of changes in resolution across the width of individual separation lanes in both systems revealed dependence in the case of the conventional gels and no dependence for the gels loaded with the micromachined instrumentation.

  2. Capillary Electrophoresis Sensitivity Enhancement Based on Adaptive Moving Average Method.

    Science.gov (United States)

    Drevinskas, Tomas; Telksnys, Laimutis; Maruška, Audrius; Gorbatsova, Jelena; Kaljurand, Mihkel

    2018-06-05

    In the present work, we demonstrate a novel approach to improve the sensitivity of the "out of lab" portable capillary electrophoretic measurements. Nowadays, many signal enhancement methods are (i) underused (nonoptimal), (ii) overused (distorts the data), or (iii) inapplicable in field-portable instrumentation because of a lack of computational power. The described innovative migration velocity-adaptive moving average method uses an optimal averaging window size and can be easily implemented with a microcontroller. The contactless conductivity detection was used as a model for the development of a signal processing method and the demonstration of its impact on the sensitivity. The frequency characteristics of the recorded electropherograms and peaks were clarified. Higher electrophoretic mobility analytes exhibit higher-frequency peaks, whereas lower electrophoretic mobility analytes exhibit lower-frequency peaks. On the basis of the obtained data, a migration velocity-adaptive moving average algorithm was created, adapted, and programmed into capillary electrophoresis data-processing software. Employing the developed algorithm, each data point is processed depending on a certain migration time of the analyte. Because of the implemented migration velocity-adaptive moving average method, the signal-to-noise ratio improved up to 11 times for sampling frequency of 4.6 Hz and up to 22 times for sampling frequency of 25 Hz. This paper could potentially be used as a methodological guideline for the development of new smoothing algorithms that require adaptive conditions in capillary electrophoresis and other separation methods.

  3. Single-cell microgel electrophoresis: an in vitro assay of radiosensitivity

    International Nuclear Information System (INIS)

    Deeley, J.O.T.; Moore, J.L.

    1993-01-01

    The results obtained by a microgel electrophoresis are comparable to conventional gel electrophoresis and elution techniques (Singh et al, 1989), DNA precipitation, alkali unwinding and cell clonogenicity assays (Olive et al, 1990). Since single cells are assessed, microgel electrophoresis is particularly appropriate for end-points such as the intercell variation in response. The simplicity, low cost and rapidity of microgel electrophoresis compared with other assays makes it particularly attractive for assessing the effects on DNA of radiation and other genotoxic agents on the general population. (Author)

  4. Effects of Storage and Granary Weevil Infestation on Gel Electrophoresis and Protein Solubility Properties of Hard and Soft Wheat Flours.

    Science.gov (United States)

    Keskin, Sule; Yalçin, Erkan; Özkaya, Hazim

    2018-02-24

    The objective of this study was to investigate the effects of storage and granary weevil, Sitophilus granarius (L.; Coleoptera: Curculionidae), infestation on pH, protein solubility (PS) and gel electrophoresis properties of meal and roller-milled flours of hard (Ceyhan-99 cv.) and soft (Eser cv.) wheat cultivars, respectively, after 6 mo of storage. Sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) technique was applied for studying the electrophoretic properties. Hard and soft wheats were infested with non-sexed S. granarius at a rate of two adults/ kg, and stored for 6 mo at 30 ± 1°C and 70 ± 5% RH. The pest-free wheat samples were used as control. The infested and its control samples were collected monthly, and after cleaning the granary weevils, they were hammer-milled or roller-milled in order to get meal flours and roller-milled flours, respectively. The effect of infestation on the storage proteins was more obvious in meal flours than that of the roller-milled flours. Granary weevil feeding resulted secreting of hydrolyzing enzymes and increased the acidity of flours; subsequently the breaking and releasing of some storage proteins generally caused a decrease in pH and an increase in PS values of the meal flours of wheat cultivars. SDS-PAGE results generally indicated that towards the end of storage, the insect population, that greatly increased, caused minor protein depletions resulting decreasing protein band intensities between 113 and 58 kDa of hard wheat meal flour and 101 and 40 kDa of soft wheat roller-milled flour. Consequently, the potential effect of changes probably occurred in high molecular weight glutenin subunits of both wheat cultivars.

  5. Molecular Typing of Acinetobacter Baumannii Clinical Strains in Tehran by Pulsed-Field Gel Electrophoresis

    Directory of Open Access Journals (Sweden)

    Neda Farahani

    2013-03-01

    Full Text Available Background & Objective : Currently, Acinetobacter baumannii is an important nosocomial pathogen insofar as its hospital outbreaks have been described from various geographical areas. Since the discrimination of strains within a species is important for delineating nosocomial outbreaks, this study was conducted with the aim of genotyping the A. baumannii clinical strains in Tehran via the pulsed-field gel electrophoresis (PFGE method, which is the most accurate method used for the typing of bacterial species.   Materials & methods: This study was performed on 70 isolates of acinetobacter baumannii isolated from patients from Baqiyatallah, Rasoole Akram, and Milad hospitals in Tehran. Cultural and biochemical methods were used for the identification of the isolates in species level, and then susceptibility tests were carried out on 50 isolates of A. baumannii using the disk diffusion method. The PFGE method was performed on the isolates by Apa I restriction enzyme. Finally, the results of the PFGE were analyzed. Result: Acinetobacter baumannii strains isolated from hospitals in Tehran showed seven different genetic patterns, two of which were sporadic . Also, genotypic profiles were different in each hospital, and different patterns of genetic resistance to common antibiotics were observed. Conclusion: A lthough diversity was observed among the strains of A. baumannii by the PFGE method in Tehran, no epidemic strains were found among them.  

  6. Electrophoresis characterisation of protein as a method to establish the entomological origin of stingless bee honeys.

    Science.gov (United States)

    Ramón-Sierra, Jesús Manuel; Ruiz-Ruiz, Jorge Carlos; de la Luz Ortiz-Vázquez, Elizabeth

    2015-09-15

    Increasing production of stingless-bee honey and the prospect of broader marker for natural and organic products indicate the need to establish parameters to determinate the entomological origin and authenticity of honey. In this research, honeys of Apis mellifera, Melipona beecheii and Trigona spp. were collected in Yucatan, Mexico. Stingless-bee honeys contained more water and less total sugars and reducing sugars. SDS-PAGE patterns show distinctive bands for each kind of honey. The SDS-PAGE pattern of A. mellifera proteins honey showed three bands with molecular weights between 10.2 and 74.8kDa, there were five proteins bands in M. beecheii honey with molecular weights between 6.1 and 97.0kDa and nine for Trigona spp. proteins between 9.3 and 86.7kDa. Conventional physicochemical parameters along with electrophoresis profiles of stingless-bee honeys proteins could be an alternative for determination of entomological origin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Molecular Analysis of Mycobacterium avium Isolates by Using Pulsed-Field Gel Electrophoresis and PCR

    Science.gov (United States)

    Pestel-Caron, Martine; Graff, Gabriel; Berthelot, Gilles; Pons, Jean-Louis; Lemeland, Jean-François

    1999-01-01

    Genetic relationships among 46 isolates of Mycobacterium avium recovered from 37 patients in a 2,500-bed hospital from 1993 to 1998 were assessed by pulsed-field gel electrophoresis (PFGE) and PCR amplification of genomic sequences located between the repetitive elements IS1245 and IS1311. Each technique enabled the identification of 27 to 32 different patterns among the 46 isolates, confirming that the genetic heterogeneity of M. avium strains is high in a given community. Furthermore, this retrospective analysis of sporadic isolates allowed us (i) to suggest the existence of two remanent strains in our region, (ii) to raise the question of the possibility of nosocomial acquisition of M. avium strains, and (iii) to document laboratory contamination. The methods applied in the present study were found to be useful for the typing of M. avium isolates. In general, both methods yielded similar results for both related and unrelated isolates. However, the isolates in five of the six PCR clusters were distributed among two to three PFGE patterns, suggesting that this PCR-based method may have limitations for the analysis of strains with low insertion sequence copy numbers or for resolution of extended epidemiologic relationships. PMID:10405383

  8. Comparative Glycoprofiling of HIV gp120 Immunogens by Capillary Electrophoresis and MALDI Mass Spectrometry

    Science.gov (United States)

    Guttman, Miklós; Váradi, Csaba; Lee, Kelly K.; Guttman, András

    2015-01-01

    The Human Immunodeficiency Virus (HIV) envelope glycoprotein (Env) is the primary antigenic feature on the surface of the virus and is of key importance in HIV vaccinology. Vaccine trials with the gp120 subunit of Env are ongoing with the recent RV144 trial showing moderate efficacy. gp120 is densely covered with N-linked glycans that are thought to help evade the host's humoral immune response. To assess how the global glycosylation patterns vary between gp120 constructs, the glycan profiles of several gp120s were examined by capillary electrophoresis with laser induced fluorescence detection and MALDI-MS. The glycosylation profiles were found to be similar for chronic vs. transmitter/founder isolates and only varied moderately between gp120s from different clades. This study revealed that the addition of specific tags, such as the gD tag used in the RV144 trial, had significant effects on the overall glycosylation patterns. Such effects are likely to influence the immunogenicity of various Env immunogens and should be considered for future vaccine strategies, emphasizing the importance of the glycosylation analysis approach described in this paper. PMID:25809283

  9. Urine pH test

    Science.gov (United States)

    ... urine test Male urinary tract References Bose A, Monk RD, Bushinsky DA. Kidney stones. In: Melmed S, Polonsky ... and its influence on urine pH. J Am Diet Assoc . 1995;95(7):791-797. PMID: 7797810 ...

  10. Exercise and Pulmonary Hypertension (PH)

    Science.gov (United States)

    ... Situations Find a Doctor PH Care Centers PHA Classroom PHA Registry Insurance Guide Specialty Pharmacy Other Resources ... no published data in the medical literature regarding routine exercise in patients with PAH. However, there are ...

  11. Quantitative two-dimensional gel electrophoresis analysis of human fibroblasts transformed by ras oncogenes.

    Science.gov (United States)

    Miller, M J; Maher, V M; McCormick, J J

    1992-11-01

    Quantitative two-dimensional gel electrophoresis was used to compare the cellular protein patterns of a normal foreskin-derived human fibroblasts cell line (LG1) and three immortal derivatives of LG1. One derivative, designated MSU-1.1 VO, was selected for its ability to grow in the absence of serum and is non-tumorigenic in athymic mice. The other two strains were selected for focus-formation following transfection with either Ha-ras or N-ras oncogenes and form high grade malignant tumors. Correspondence and cluster analysis provided a nonbiased estimate of the relative similarity of the different two-dimensional patterns. These techniques separated the gel patterns into three distinct classes: LG1, MSU-1.1 VO, and the ras transformed cell strains. The MSU-1.1 VO cells were more closely related to the parental LG1 than to the ras-transformed cells. The differences between the three classes were primarily quantitative in nature: 16% of the spots demonstrated statistically significant changes (P 2) in the rate of incorporation of radioactive amino acids. The patterns from the two ras-transformed cell strains were similar, and variations in the expression of proteins that occurred between the separate experiments obscured consistent differences between the Ha-ras and N-ras transformed cells. However, while only 9 out of 758 spots were classified as different (1%), correspondence analysis could consistently separate the two ras transformants. One of these spots was five times more intense in the Ha-ras transformed cells than the N-ras.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. PhEDEx Data Service

    International Nuclear Information System (INIS)

    Egeland, Ricky; Wildish, Tony; Huang, Chih-Hao

    2010-01-01

    The PhEDEx Data Service provides access to information from the central PhEDEx database, as well as certificate-authenticated managerial operations such as requesting the transfer or deletion of data. The Data Service is integrated with the 'SiteDB' service for fine-grained access control, providing a safe and secure environment for operations. A plug-in architecture allows server-side modules to be developed rapidly and easily by anyone familiar with the schema, and can automatically return the data in a variety of formats for use by different client technologies. Using HTTP access via the Data Service instead of direct database connections makes it possible to build monitoring web-pages with complex drill-down operations, suitable for debugging or presentation from many aspects. This will form the basis of the new PhEDEx website in the near future, as well as providing access to PhEDEx information and certificate-authenticated services for other CMS dataflow and workflow management tools such as CRAB, WMCore, DBS and the dashboard. A PhEDEx command-line client tool provides one-stop access to all the functions of the PhEDEx Data Service interactively, for use in simple scripts that do not access the service directly. The client tool provides certificate-authenticated access to managerial functions, so all the functions of the PhEDEx Data Service are available to it. The tool can be expanded by plug-ins which can combine or extend the client-side manipulation of data from the Data Service, providing a powerful environment for manipulating data within PhEDEx.

  13. Programmable pH buffers

    Science.gov (United States)

    Gough, Dara Van; Huber, Dale L.; Bunker, Bruce C.; Roberts, Mark E.

    2017-01-24

    A programmable pH buffer comprises a copolymer that changes pK.sub.a at a lower critical solution temperature (LCST) in water. The copolymer comprises a thermally programmable polymer that undergoes a hydrophobic-to-hydrophilic phase change at the LCST and an electrolytic polymer that exhibits acid-base properties that are responsive to the phase change. The programmable pH buffer can be used to sequester CO.sub.2 into water.

  14. Phene Plate (PhP) biochemical fingerprinting. A screening method for epidemiological typing of enterococcal isolates.

    Science.gov (United States)

    Saeedi, B; Tärnberg, M; Gill, H; Hällgren, A; Jonasson, J; Nilsson, L E; Isaksson, B; Kühn, I; Hanberger, H

    2005-09-01

    Pulsed-field gel electrophoresis (PFGE) is currently considered the gold standard for genotyping of enterococci. However, PFGE is both expensive and time-consuming. The purpose of this study was to investigate whether the PhP system can be used as a reliable clinical screening method for detection of genetically related isolates of enterococci. If so, it should be possible to minimize the number of isolates subjected to PFGE typing, which would save time and money. Ninety-nine clinical enterococcal isolates were analysed by PhP (similarity levels 0.90-0.975) and PFGE (similarity levels PhP also belong to the same cluster according to PFGE, i.e. p(A(PFGE)=B(PFGE) * A(PhP)=B(PhP)), and the probability that a pair of isolates of different types according to PhP also belong to different clusters according to PFGE, i.e. p(A(PFGE) not equalB(PFGE) * A(PhP) not equalB(PhP)), was relatively high for E. faecalis (0.86 and 0.96, respectively), but was lower for E. faecium (0.51 and 0.77, respectively). The concordance which shows the probability that PhP and PFGE agree on match or mismatch was 86%-93% for E. faecalis and 54%-66% for E. faecium, which indicates that the PhP method may be useful for epidemiological typing of E. faecalis in the current settings but not for E. faecium.

  15. Describing temporal variation in reticuloruminal pH using continuous monitoring data

    DEFF Research Database (Denmark)

    Denwood, M. J.; Kleen, J. L.; Jensen, D. B.

    2018-01-01

    Reticuloruminal pH has been linked to subclinical disease in dairy cattle, leading to considerable interest in identifying pH observations below a given threshold. The relatively recent availability of continuously monitored data from pH boluses gives new opportunities for characterizing the normal...... patterns of pH over time and distinguishing these from abnormal patterns using more sensitive and specific methods than simple thresholds. We fitted a series of statistical models to continuously monitored data from 93 animals on 13 farms to characterize normal variation within and between animals. We used...... a subset of the data to relate deviations from the normal pattern to the productivity of 24 dairy cows from a single herd. Our findings show substantial variation in pH characteristics between animals, although animals within the same farm tended to show more consistent patterns. There was strong evidence...

  16. [Analysis of tartrazine aluminum lake and sunset yellow aluminum lake in foods by capillary zone electrophoresis].

    Science.gov (United States)

    Zhang, Yiding; Chang, Cuilan; Guo, Qilei; Cao, Hong; Bai, Yu; Liu, Huwei

    2014-04-01

    A novel analytical method for tartrazine aluminum lake and sunset yellow aluminum lake using capillary zone electrophoresis (CZE) was studied. The pigments contained in the color lakes were successfully separated from the aluminum matrix in the pre-treatment process, which included the following steps: dissolve the color lakes in 0.1 mol/L H2SO4, adjust the pH of the solution to 5.0, then mix it with the solution of EDTA x 2Na and heat it in a water bath, then use polyamide powder as the stationary phase of solid phase extraction to separate the pigments from the solution, and finally elute the pigments with 0.1 mol/L NaOH. The CZE conditions systematically optimized for tartrazine aluminum lake were: 48.50 cm of a fused silica capillary with 40.00 cm effective length and 50 microm i. d., the temperature controlled at 20.0 degrees C, 29.0 kV applied, HPO4(2-)-PO4(3-) (0.015 mol/L, pH 11.45) solution as running buffer, detection at 263 nm. The conditions for sunset yellow aluminum lake were: the same capillary and temperature, 25.0 kV applied, HPO4(2-)-PO4(3-) (0.025 mol/L, pH 11.45) solution as running buffer, detection at 240 nm. The limits of detection were 0.26 mg/L and 0.27 mg/L, and the linear ranges were 0.53-1.3 x 10(2) mg/L and 0.54-1.4 x 10(2) mg/L for tartrazine aluminum lake and sunset yellow aluminum lake, respectively. The RSDs were 4.3% and 5.7% (run to run, n = 6), 5.6% and 6.0% (day to day, n = 6) for tartrazine aluminum lake and sunset yellow aluminum lake, respectively. Further developments for this method could make it a routinely used method analyzing color lakes in foods.

  17. Effects of pH on embryo tolerance and adult behavior in the tiger salamander, Ambystoma tigrinum tigrinum

    Energy Technology Data Exchange (ETDEWEB)

    Whiteman, H H; Howard, R D; Whitten, K A [Purdue Univ., Lafayette, IN (United States). Dept. of Biological Sciences

    1995-08-01

    Adult discrimination ability and embryo performance was examined under different pH conditions in the eastern tiger salamander. Individuals from three populations were collected in habitats that differed naturally in pH. Two pH treatments were used to determine adult pH discrimination ability, and eight pH treatments to evaluate embryo performance. Results suggested that the pH of the source-population habitat could influence breeding-habitat discrimination by adults. Decreasing pH produced similar patterns of lethal and sublethal effects on embryos from the three populations, with reduced performance at low pH. The pH at which 50% mortality occurs was estimated at 4.2, suggesting that tiger salamanders were relatively acid tolerant. The study suggested that adult behavior patterns could influence the success of population reintroductions to previously acidified areas. 78 refs., 2 tabs., 4 figs.

  18. Sample preparation guidelines for two-dimensional electrophoresis.

    Science.gov (United States)

    Posch, Anton

    2014-12-01

    Sample preparation is one of the key technologies for successful two-dimensional electrophoresis (2DE). Due to the great diversity of protein sample types and sources, no single sample preparation method works with all proteins; for any sample the optimum procedure must be determined empirically. This review is meant to provide a broad overview of the most important principles in sample preparation in order to avoid a multitude of possible pitfalls. Sample preparation protocols from the expert in the field were screened and evaluated. On the basis of these protocols and my own comprehensive practical experience important guidelines are given in this review. The presented guidelines will facilitate straightforward protocol development for researchers new to gel-based proteomics. In addition the available choices are rationalized in order to successfully prepare a protein sample for 2DE separations. The strategies described here are not limited to 2DE and can also be applied to other protein separation techniques.

  19. Protein Separation by Capillary Gel Electrophoresis: A Review

    Science.gov (United States)

    Zhu, Zaifang; Lu, Joann J.; Liu, Shaorong

    2011-01-01

    Capillary gel electrophoresis (CGE) has been used for protein separation for more than two decades. Due to the technology advancement, current CGE methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of protein-based pharmaceuticals and quality controls. In light of this progress, we survey 147 papers related to CGE separations of proteins and present an overview of this technology. We first introduce briefly the early development of CGE. We then review the methodology, in which we specifically describe the matrices, coatings, and detection strategies used in CGE. CGE using microfabricated channels and incorporation of CGE with two-dimensional protein separations are also discussed in this section. We finally present a few representative applications of CGE for separating proteins in real-world samples. PMID:22122927

  20. Determination of Betaine in Lycii Cortex by Capillary Electrophoresis

    Science.gov (United States)

    Peng, Xuewei; Liu, Haixing

    2017-12-01

    This paper presents the determination of betaine content in Lycii Cortex by high performance capillary electrophoresis (HPCE) method. The borax solution was chosen as buffer solution, and its concentration was 40 mmol at a constant voltage of 20kV and injecting pressure time of 10s at 14°C. Linearity was kept in the concent ration range of 0.0113∼1.45mg of betaine with correlation coefficient of 0.9. The content of betaine in Lycii Cortex was 61.9 mg/g (RSD = 13.4%) (n = 7). The recovery was in the range of 86.6% - 118.1% (n=4). This method is specific, simple and rapid and accurate, which is suitable for the detection of the content of betaine in Lycii Cortex.

  1. Determination of Betaine in Jujube by Capillary Electrophoresis

    Science.gov (United States)

    Han, Likun; Liu, Haixing; Peng, Xuewei

    2017-12-01

    This paper presents the determination of betaine content in jujube by high performance capillary electrophoresis (HPCE) method. The borax solution was chosen as buffer solution, and its concentration was 40 mmol at a constant voltage of 20kV and injecting pressure time of 10s at 14°C. Linearity was kept in the concent ration range of 0.0113∼1.45mg of betaine with correlation coefficient of 0.9. The content of betaine in jujube was 85.91 mg/g (RSD = 16.6%) (n = 6). The recovery of betaine in jujube sample was in the range of 86.2% - 116.6% (n=3). This method is specific, simple and rapid and accurate, which is suitable for the detection of the content of betaine in jujube.

  2. Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: Assay development and surface roughness measurements

    NARCIS (Netherlands)

    Weiller, Bruce H.; Ceriotti, Laura; Shibata, Takayuki; Rein, Dietrich; Roberts, Matthew A.; Lichtenberg, Jan; German, J. Bruce; De Rooij, Nico F.; Verpoorte, Elisabeth

    2002-01-01

    The development of a new assay for lipoproteins by capillary electrophoresis in fused-silica capillaries and in glass microdevices is described in this paper. The separation of low-density (LDL) and high-density (HDL) lipoproteins by capillary zone electrophoresis is demonstrated in fused-silica

  3. Instrumental development of novel detection and separation methods for capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Garner, Tommy [Iowa State Univ., Ames, IA (United States)

    1993-07-01

    After a general introduction, this thesis is divided into 3 parts: indirect fluorescence detection of sugars separated by capillary zone electrophoresis with visible laser excitation, absorption detection in capillary electrophoresis by fluorescence energy transfer, and increased selectivity for electrochromatography by dynamic ion exchange.

  4. Simulation of Two Dimensional Electrophoresis and Tandem Mass Spectrometry for Teaching Proteomics

    Science.gov (United States)

    Fisher, Amanda; Sekera, Emily; Payne, Jill; Craig, Paul

    2012-01-01

    In proteomics, complex mixtures of proteins are separated (usually by chromatography or electrophoresis) and identified by mass spectrometry. We have created 2DE Tandem MS, a computer program designed for use in the biochemistry, proteomics, or bioinformatics classroom. It contains two simulations--2D electrophoresis and tandem mass spectrometry.…

  5. The Cutoff Level for Urine Protein in Urine Immunofixation Electrophoresis.

    Science.gov (United States)

    Ellidag, Hamit Yasar; Curek, Gulten; Eren, Esin; Aydin, Ozgur; Yilmaz, Necat

    2015-01-01

    Immunofixation electrophoresis (IFE) maintains its importance in diagnosing monoclonal gammopathies. In particular, urine IFE detects free light chains (FLC) in urine samples even at low concentrations and offers higher sensitivity compared to serum electrophoresis and serum IFE. The aim of the present study was to determine the place and significance of quantitative urinary protein measurement before IFE in interpreting the results of subsequent IFE and to determine the most appropriate protein concentrations for the appearance of bands. The records of a total of 600 patients, who underwent screening for Bence Jones proteinuria using IFE on 24-hour urine, were retrospectively reviewed. Urine IFE was performed using Helena SAS-I and SAS-I devices. The total protein concentration in the urine was quantitatively determined by the Pyrogallol red method, and the urine albumin level was determined using the immunoturbidimetric method. These analyses were measured on an Olympus/Beckmann AU5800. The evaluation of IFE results revealed that 311 patients had normal results, 108 patients had monoclonal bands, five patients had biclonal bands, 28 had polyclonal bands, and 148 patients had various degrees of proteinuria. ROC curves were created in order to determine the most appropriate urinary protein and albumin levels to observe bands in IFE. Accordingly, urine baseline protein level (mg/dL) showed the highest AUC value (cutoff value: 19.4 mg/dL, sensitivity: 92%, specificity: 98.2%, AUC: 0.972). The present study showed that quantitative protein measurement before IFE eliminated the disadvantages associated with the IFE method and its interpretation.

  6. Photopatterned free-standing polyacrylamide gels for microfluidic protein electrophoresis.

    Science.gov (United States)

    Duncombe, Todd A; Herr, Amy E

    2013-06-07

    Designed for compatibility with slab-gel polyacrylamide gel electrophoresis (PAGE) reagents and instruments, we detail development of free-standing polyacrylamide gel (fsPAG) microstructures supporting electrophoretic performance rivalling that of microfluidic platforms. For the protein electrophoresis study described here, fsPAGE lanes are comprised of a sample reservoir and contiguous separation gel. No enclosed microfluidic channels are employed. The fsPAG devices (120 μm tall) are directly photopatterned atop of and covalently attached to planar polymer or glass surfaces. Leveraging the fast prototype-test cycle - significantly faster than mold based fabrication techniques - we optimize the fsPAG architecture to minimize injection dispersion for rapid (prototyping of the fsPAGE provides researchers a powerful tool for developing custom analytical assays. We highlight the utility of assay customization by fabricating a polyacrylamide gel with a spatial pore-size distribution and demonstrate the resulting enhancement in separation performance over a uniform gel. Further, we up-scale from a unit separation to an array of 96 concurrent fsPAGE assays in 10 min run time driven by one electrode pair. The fsPAG array layout matches that of a 96-well plate to facilitate integration of the planar free standing gel array with multi-channel pipettes while remaining compatible with conventional slab-gel PAGE reagents, such as staining for label-free protein detection. Notably, the entire fsPAGE workflow from fabrication, to operation, and readout uses readily available materials and instruments - making this technique highly accessible.

  7. Improving precision in gel electrophoresis by stepwisely decreasing variance components.

    Science.gov (United States)

    Schröder, Simone; Brandmüller, Asita; Deng, Xi; Ahmed, Aftab; Wätzig, Hermann

    2009-10-15

    Many methods have been developed in order to increase selectivity and sensitivity in proteome research. However, gel electrophoresis (GE) which is one of the major techniques in this area, is still known for its often unsatisfactory precision. Percental relative standard deviations (RSD%) up to 60% have been reported. In this case the improvement of precision and sensitivity is absolutely essential, particularly for the quality control of biopharmaceuticals. Our work reflects the remarkable and completely irregular changes of the background signal from gel to gel. This irregularity was identified as one of the governing error sources. These background changes can be strongly reduced by using a signal detection in the near-infrared (NIR) range. This particular detection method provides the most sensitive approach for conventional CCB (Colloidal Coomassie Blue) stained gels, which is reflected in a total error of just 5% (RSD%). In order to further investigate variance components in GE, an experimental Plackett-Burman screening design was performed. The influence of seven potential factors on the precision was investigated using 10 proteins with different properties analyzed by NIR detection. The results emphasized the individuality of the proteins. Completely different factors were identified to be significant for each protein. However, out of seven investigated parameters, just four showed a significant effect on some proteins, namely the parameters of: destaining time, staining temperature, changes of detergent additives (SDS and LDS) in the sample buffer, and the age of the gels. As a result, precision can only be improved individually for each protein or protein classes. Further understanding of the unique properties of proteins should enable us to improve the precision in gel electrophoresis.

  8. DNA double-strand break measurement in mammalian cells by pulsed-field gel electrophoresis: an approach using restriction enzymes and gene probing

    International Nuclear Information System (INIS)

    Loebrich, M.; Ikpeme, S.; Kiefer, J.

    1994-01-01

    DNA samples prepared from human SP 3 cells, which had not been exposed to various doses of X-ray, were treated with NotI restriction endonuclease before being run in a contour-clamped homogeneous electrophoresis system. The restriction enzyme cuts the DNA at defined positions delivering DNA sizes which can be resolved by pulsed-field gel electrophoresis (PFGE). In order to investigate only one of the DNA fragments, a human lactoferrin cDNA, pHL-41, was hybridized to the DNA separated by PFGE. As a result, only the DNA fragment which contains the hybridized gene was detected resulting in a one-band pattern. The decrease of this band was found to be exponential with increasing radiation dose. From the slope, a double-strand break induction rate of (6.3±0.7) x 10 -3 /Mbp/Gy was deduced for 80 kV X-rays. (Author)

  9. The gel electrophoresis markup language (GelML) from the Proteomics Standards Initiative.

    Science.gov (United States)

    Gibson, Frank; Hoogland, Christine; Martinez-Bartolomé, Salvador; Medina-Aunon, J Alberto; Albar, Juan Pablo; Babnigg, Gyorgy; Wipat, Anil; Hermjakob, Henning; Almeida, Jonas S; Stanislaus, Romesh; Paton, Norman W; Jones, Andrew R

    2010-09-01

    The Human Proteome Organisation's Proteomics Standards Initiative has developed the GelML (gel electrophoresis markup language) data exchange format for representing gel electrophoresis experiments performed in proteomics investigations. The format closely follows the reporting guidelines for gel electrophoresis, which are part of the Minimum Information About a Proteomics Experiment (MIAPE) set of modules. GelML supports the capture of metadata (such as experimental protocols) and data (such as gel images) resulting from gel electrophoresis so that laboratories can be compliant with the MIAPE Gel Electrophoresis guidelines, while allowing such data sets to be exchanged or downloaded from public repositories. The format is sufficiently flexible to capture data from a broad range of experimental processes, and complements other PSI formats for MS data and the results of protein and peptide identifications to capture entire gel-based proteome workflows. GelML has resulted from the open standardisation process of PSI consisting of both public consultation and anonymous review of the specifications.

  10. Multilocus Sequence Typing Scheme versus Pulsed-Field Gel Electrophoresis for Typing Mycobacterium abscessus Isolates

    Science.gov (United States)

    Machado, Gabriel Esquitini; Matsumoto, Cristianne Kayoko; Chimara, Erica; Duarte, Rafael da Silva; de Freitas, Denise; Palaci, Moises; Hadad, David Jamil; Lima, Karla Valéria Batista; Lopes, Maria Luiza; Ramos, Jesus Pais; Campos, Carlos Eduardo; Caldas, Paulo César; Heym, Beate

    2014-01-01

    Outbreaks of infections by rapidly growing mycobacteria following invasive procedures, such as ophthalmological, laparoscopic, arthroscopic, plastic, and cardiac surgeries, mesotherapy, and vaccination, have been detected in Brazil since 1998. Members of the Mycobacterium chelonae-Mycobacterium abscessus group have caused most of these outbreaks. As part of an epidemiological investigation, the isolates were typed by pulsed-field gel electrophoresis (PFGE). In this project, we performed a large-scale comparison of PFGE profiles with the results of a recently developed multilocus sequence typing (MLST) scheme for M. abscessus. Ninety-three isolates were analyzed, with 40 M. abscessus subsp. abscessus isolates, 47 M. abscessus subsp. bolletii isolates, and six isolates with no assigned subspecies. Forty-five isolates were obtained during five outbreaks, and 48 were sporadic isolates that were not associated with outbreaks. For MLST, seven housekeeping genes (argH, cya, glpK, gnd, murC, pta, and purH) were sequenced, and each isolate was assigned a sequence type (ST) from the combination of obtained alleles. The PFGE patterns of DraI-digested DNA were compared with the MLST results. All isolates were analyzable by both methods. Isolates from monoclonal outbreaks showed unique STs and indistinguishable or very similar PFGE patterns. Thirty-three STs and 49 unique PFGE patterns were identified among the 93 isolates. The Simpson's index of diversity values for MLST and PFGE were 0.69 and 0.93, respectively, for M. abscessus subsp. abscessus and 0.96 and 0.97, respectively, for M. abscessus subsp. bolletii. In conclusion, the MLST scheme showed 100% typeability and grouped monoclonal outbreak isolates in agreement with PFGE, but it was less discriminative than PFGE for M. abscessus. PMID:24899019

  11. Molecular analysis of Salmonella enteritidis isolates from the Caribbean by pulsed-field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Abiodun Adesiyun

    2000-11-01

    Full Text Available Using pulsed-field gel electrophoresis (PFGE, between 1987 and 1996 we analyzed Salmonella enteritidis isolates from gastroenteritis cases in four Caribbean countries: Barbados, Saint Kitts and Nevis, Saint Lucia, and Trinidad and Tobago. We also determined the resistance of the isolates to 12 antimicrobial agents. Of the 129 isolates of S. enteritidis available for testing, DNA digested by XbaI revealed 13 distinctive PFGE patterns. The most prevalent XbaI PFGE patterns were group 1 (88 of 129 isolates, 68.2% and group 2 (26 of 129, 20.2%. The patterns found among S. enteritidis isolates correlated with the geographical origin of the isolates. Of the 28 isolates from Barbados, 20 of them (71.4% belonged to XbaI PFGE group 2, and of the 93 isolates from Trinidad and Tobago, 78 of them (83.9% belonged to group 1. SpeI digestion of S. enteritidis genome was not as discriminatory as XbaI. Overall, of the 129 isolates, 67 of them (51.9% exhibited resistance to one or more of the 12 antimicrobial agents that we tested. The prevalence of resistance was 53.8% for the S. enteritidis isolates tested from Trinidad and Tobago, 50.0% for those from Barbados, 28.6% for those from Saint Lucia, and 100.0% for one isolate from the island of Saint Kitts. Resistance was highest to triple sulfur (59 of 129 isolates, 45.7%, followed by furadantoin (10 of 129, 7.8%, ampicillin (7 of 129, 5.4%, and carbamycin (5 of 129, 3.9%.

  12. Multilocus sequence typing scheme versus pulsed-field gel electrophoresis for typing Mycobacterium abscessus isolates.

    Science.gov (United States)

    Machado, Gabriel Esquitini; Matsumoto, Cristianne Kayoko; Chimara, Erica; Duarte, Rafael da Silva; de Freitas, Denise; Palaci, Moises; Hadad, David Jamil; Lima, Karla Valéria Batista; Lopes, Maria Luiza; Ramos, Jesus Pais; Campos, Carlos Eduardo; Caldas, Paulo César; Heym, Beate; Leão, Sylvia Cardoso

    2014-08-01

    Outbreaks of infections by rapidly growing mycobacteria following invasive procedures, such as ophthalmological, laparoscopic, arthroscopic, plastic, and cardiac surgeries, mesotherapy, and vaccination, have been detected in Brazil since 1998. Members of the Mycobacterium chelonae-Mycobacterium abscessus group have caused most of these outbreaks. As part of an epidemiological investigation, the isolates were typed by pulsed-field gel electrophoresis (PFGE). In this project, we performed a large-scale comparison of PFGE profiles with the results of a recently developed multilocus sequence typing (MLST) scheme for M. abscessus. Ninety-three isolates were analyzed, with 40 M. abscessus subsp. abscessus isolates, 47 M. abscessus subsp. bolletii isolates, and six isolates with no assigned subspecies. Forty-five isolates were obtained during five outbreaks, and 48 were sporadic isolates that were not associated with outbreaks. For MLST, seven housekeeping genes (argH, cya, glpK, gnd, murC, pta, and purH) were sequenced, and each isolate was assigned a sequence type (ST) from the combination of obtained alleles. The PFGE patterns of DraI-digested DNA were compared with the MLST results. All isolates were analyzable by both methods. Isolates from monoclonal outbreaks showed unique STs and indistinguishable or very similar PFGE patterns. Thirty-three STs and 49 unique PFGE patterns were identified among the 93 isolates. The Simpson's index of diversity values for MLST and PFGE were 0.69 and 0.93, respectively, for M. abscessus subsp. abscessus and 0.96 and 0.97, respectively, for M. abscessus subsp. bolletii. In conclusion, the MLST scheme showed 100% typeability and grouped monoclonal outbreak isolates in agreement with PFGE, but it was less discriminative than PFGE for M. abscessus. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  13. Molecular analysis of Salmonella enteritidis isolates from the Caribbean by pulsed-field gel electrophoresis.

    Science.gov (United States)

    Adesiyun, A; Carson, A; McAdoo, K; Bailey, C

    2000-11-01

    Using pulsed-field gel electrophoresis (PFGE), between 1987 and 1996 we analyzed Salmonella enteritidis isolates from gastroenteritis cases in four Caribbean countries: Barbados, Saint Kitts and Nevis, Saint Lucia, and Trinidad and Tobago. We also determined the resistance of the isolates to 12 antimicrobial agents. Of the 129 isolates of S. enteritidis available for testing, DNA digested by XbaI revealed 13 distinctive PFGE patterns. The most prevalent XbaI PFGE patterns were group 1 (88 of 129 isolates, 68.2%) and group 2 (26 of 129, 20.2%). The patterns found among S. enteritidis isolates correlated with the geographical origin of the isolates. Of the 28 isolates from Barbados, 20 of them (71.4%) belonged to XbaI PFGE group 2, and of the 93 isolates from Trinidad and Tobago, 78 of them (83.9%) belonged to group 1. SpeI digestion of S. enteritidis genome was not as discriminatory as XbaI. Overall, of the 129 isolates, 67 of them (51.9%) exhibited resistance to one or more of the 12 antimicrobial agents that we tested. The prevalence of resistance was 53.8% for the S. enteritidis isolates tested from Trinidad and Tobago, 50.0% for those from Barbados, 28.6% for those from Saint Lucia, and 100.0% for one isolate from the island of Saint Kitts. Resistance was highest to triple sulfur (59 of 129 isolates, 45.7%), followed by furadantoin (10 of 129, 7.8%), ampicillin (7 of 129, 5.4%), and carbamycin (5 of 129, 3.9%).

  14. Molecular analysis of Salmonella enteritidis isolates from the Caribbean by pulsed-field gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Adesiyun Abiodun

    2000-01-01

    Full Text Available Using pulsed-field gel electrophoresis (PFGE, between 1987 and 1996 we analyzed Salmonella enteritidis isolates from gastroenteritis cases in four Caribbean countries: Barbados, Saint Kitts and Nevis, Saint Lucia, and Trinidad and Tobago. We also determined the resistance of the isolates to 12 antimicrobial agents. Of the 129 isolates of S. enteritidis available for testing, DNA digested by XbaI revealed 13 distinctive PFGE patterns. The most prevalent XbaI PFGE patterns were group 1 (88 of 129 isolates, 68.2% and group 2 (26 of 129, 20.2%. The patterns found among S. enteritidis isolates correlated with the geographical origin of the isolates. Of the 28 isolates from Barbados, 20 of them (71.4% belonged to XbaI PFGE group 2, and of the 93 isolates from Trinidad and Tobago, 78 of them (83.9% belonged to group 1. SpeI digestion of S. enteritidis genome was not as discriminatory as XbaI. Overall, of the 129 isolates, 67 of them (51.9% exhibited resistance to one or more of the 12 antimicrobial agents that we tested. The prevalence of resistance was 53.8% for the S. enteritidis isolates tested from Trinidad and Tobago, 50.0% for those from Barbados, 28.6% for those from Saint Lucia, and 100.0% for one isolate from the island of Saint Kitts. Resistance was highest to triple sulfur (59 of 129 isolates, 45.7%, followed by furadantoin (10 of 129, 7.8%, ampicillin (7 of 129, 5.4%, and carbamycin (5 of 129, 3.9%.

  15. Describing temporal variation in reticuloruminal pH using continuous monitoring data.

    Science.gov (United States)

    Denwood, M J; Kleen, J L; Jensen, D B; Jonsson, N N

    2018-01-01

    Reticuloruminal pH has been linked to subclinical disease in dairy cattle, leading to considerable interest in identifying pH observations below a given threshold. The relatively recent availability of continuously monitored data from pH boluses gives new opportunities for characterizing the normal patterns of pH over time and distinguishing these from abnormal patterns using more sensitive and specific methods than simple thresholds. We fitted a series of statistical models to continuously monitored data from 93 animals on 13 farms to characterize normal variation within and between animals. We used a subset of the data to relate deviations from the normal pattern to the productivity of 24 dairy cows from a single herd. Our findings show substantial variation in pH characteristics between animals, although animals within the same farm tended to show more consistent patterns. There was strong evidence for a predictable diurnal variation in all animals, and up to 70% of the observed variation in pH could be explained using a simple statistical model. For the 24 animals with available production information, there was also a strong association between productivity (as measured by both milk yield and dry matter intake) and deviations from the expected diurnal pattern of pH 2 d before the productivity observation. In contrast, there was no association between productivity and the occurrence of observations below a threshold pH. We conclude that statistical models can be used to account for a substantial proportion of the observed variability in pH and that future work with continuously monitored pH data should focus on deviations from a predictable pattern rather than the frequency of observations below an arbitrary pH threshold. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  16. Ion transport under the effect of an electric field in porous medium: application to the separation of rare earths by focalization electrophoresis

    International Nuclear Information System (INIS)

    Vieira-Nunes, A.I.

    1999-01-01

    Trivalent ions of rare earth elements have very similar properties and their difficult separation each from another is usually carried out by liquid-liquid extraction or ion exchange. Focalization electrophoresis represents an alternative route to the usual techniques. The purpose of this work consisted of the fundamental investigation of ion transport phenomena in electrophoretic processes. Focalization electrophoresis is suitable for separation of amphoteric species such as rare earth ions, using a pH gradient in the cell and upon addition of a complexed agent e. g. EDTA. This technique relies upon the difference in iso-electrical points of the considered species, being under the form of free cation near the anode, and in the form of anionic complexed species closer to the cathode. Rare earth species are submitted to the antagonist effects of diffusion and migration, enabling their focalization to occur at the iso-electrical point, corresponding to nil value of their effective mobility. Following a literature survey on rare earth elements and electrophoresis processes, the document describes theoretical and experimental investigations of complexation equilibria of some rare earth elements, namely lanthanum, neodymium, praseodymium and cerium, depending on pH. Values for the iso-electrical points could be estimated. Transport and focalization phenomena in view of rare earth separation, are dealt in the last chapter. Investigations were first carried out without forced circulation of the electrolyte solution and the transient behavior of the system allowed operating conditions to be design and built-up of a continuous device, more suitable to separation, and provided with 42 potential and 42 temperature sensors: the results of the preliminary runs, in form of variable profiles, are presented and discussed. (author)

  17. Diurnal variation of intraoral pH and temperature.

    Science.gov (United States)

    Choi, Jung Eun; Lyons, Karl M; Kieser, Jules A; Waddell, Neil J

    2017-01-01

    The aim of this study was to measure continuously the intraoral pH and temperature of healthy individuals to investigate their diurnal variations. Seventeen participants (mean age, 31±9 years) wore a custom-made intraoral appliance fitted with a pH probe and thermocouple for two sets of 24 h, while carrying out normal daily activities including sleep. The continuous changes in intraoral pH and temperature were captured using a sensor placed on the palatal aspect of the upper central incisors. The collected data were categorised into different status (awake and sleep) and periods (morning, afternoon, evening and night). Both quantitative and qualitative analyses were conducted. The intraoral pH change was found to show a distinctive daily rhythm, showing a 12-h interval between maximum (7.73) and minimum (6.6) pH values. The maximum and minimum values were found to repeat after 24 h. The mean pH over 48 h (two sets of 24 h) was found to be 7.27 (±0.74). There was significant difference found in pH when subjects were awake and asleep and different periods during the day ( P pH. There was a significant difference found in temperature depending on the time of the day, except between morning and afternoon ( P =0.78). Our results showed that there is a distinctive daily, circadian-like pattern in intraoral pH variation over a 24-h period, which has been considered as one of the risk factors in sleep-related dental diseases.

  18. Investigation of folic acid stability in fortified instant noodles by use of capillary electrophoresis and reversed-phase high performance liquid chromatography.

    Science.gov (United States)

    Hau Fung Cheung, Rodney; Morrison, Paul D; Small, Darryl M; Marriott, Philip J

    2008-12-05

    A single enzyme treatment with alpha-amylase, prior to the quantification of added folic acid (FA) in fortified instant fried Asian noodles with analysis performed by capillary zone electrophoresis (CZE) and reversed-phase high performance liquid chromatography (RP-HPLC) with UV detection, is described. The method was validated and optimized for capillary electrophoresis (CE) with separation achieved using a 8 mM phosphate-12 mM borate run buffer with 5% MeOH at pH 9.5. FA was well separated from matrix components with nicotinic acid (NA) employed as an internal standard. In a comparative study, separation of FA was performed using HPLC with a mobile phase consisting of 27% MeOH (v/v) in aqueous potassium phosphate buffer (3.5 mM KH(2)PO(4) and 3.2 mM K(2)HPO(4)), pH 8.5, and containing 5 mM tetrabutylammonium dihydrogen phosphate as an ion-pairing agent. For both methods, excellent results were obtained for various analytical parameters including linearity, accuracy and precision. The limit of detection was calculated to be 2.2 mg/L for CE without sample stacking and 0.10 mg/L with high performance liquid chromatography (HPLC). Sample extraction involved homogenization and enzymatic extraction with alpha-amylase. Results indicated that FA was stable during four main stages of instant fried noodle manufacturing (dough crumbs, cut sheets, steaming and frying).

  19. Quality evaluation of Guan-Xin-Ning injection based on fingerprint analysis and simultaneous separation and determination of seven bioactive constituents by capillary electrophoresis.

    Science.gov (United States)

    Xu, Liying; Chang, Ruimiao; Chen, Meng; Li, Lou; Huang, Yayun; Zhang, Hongfen; Chen, Anjia

    2017-12-01

    The purpose of this study was to develop a comprehensive, rapid and practical capillary electrophoresis (CE) method for quality control (QC) of Guan-Xin-Ning (GXN) injection based on fingerprint analysis and simultaneous separation and determination of seven constituents. In fingerprint analysis, a capillary zone electrophoresis (CZE) method with a running buffer of 30 mM borate solution (pH 9.3) was established. Meanwhile, ten batches of samples were used to establish the fingerprint electropherogram and 34 common peaks were obtained within 20 min. The RSD of relative migration times (RMT) and relative peak areas (RPA) were less than 5%. In order to further evaluate the quality of GXN injection, a micellar electrokinetic chromatography (MEKC) method was developed for simultaneous separation and determination of bioactive constituents. Seven components reached baseline separation with a running buffer containing 35 mM SDS and 45 mM borate solution (pH 9.3). A good linearity was obtained with correlation coefficients from 0.9906 to 0.9997. The LOD and LOQ ranged from 0.12 to 1.50 μg/mL and from 0.40 to 4.90 μg/mL, respectively. The recoveries ranged between 99.0 and 104.4%. Therefore, it was concluded that the proposed method can be used for full-scale quality analysis of GXN injection. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Detection by denaturing gradient gel electrophoresis of ammonia-oxidizing bacteria in microcosms of crude oil-contaminated mangrove sediments.

    Science.gov (United States)

    dos Santos, A C F; Marques, E L S; Gross, E; Souza, S S; Dias, J C T; Brendel, M; Rezende, R P

    2012-01-27

    Currently, the effect of crude oil on ammonia-oxidizing bacterium communities from mangrove sediments is little understood. We studied the diversity of ammonia-oxidizing bacteria in mangrove microcosm experiments using mangrove sediments contaminated with 0.1, 0.5, 1, 2, and 5% crude oil as well as non-contaminated control and landfarm soil from near an oil refinery in Camamu Bay in Bahia, Brazil. The evolution of CO(2) production in all crude oil-contaminated microcosms showed potential for mineralization. Cluster analysis of denaturing gradient gel electrophoresis-derived samples generated with primers for gene amoA, which encodes the functional enzyme ammonia monooxygenase, showed differences in the sample contaminated with 5% compared to the other samples. Principal component analysis showed divergence of the non-contaminated samples from the 5% crude oil-contaminated sediment. A Venn diagram generated from the banding pattern of PCR-denaturing gradient gel electrophoresis was used to look for operational taxonomic units (OTUs) in common. Eight OTUs were found in non-contaminated sediments and in samples contaminated with 0.5, 1, or 2% crude oil. A Jaccard similarity index of 50% was found for samples contaminated with 0.1, 0.5, 1, and 2% crude oil. This is the first study that focuses on the impact of crude oil on the ammonia-oxidizing bacterium community in mangrove sediments from Camamu Bay.

  1. Salicylic acid determination in estuarine and riverine waters using hollow fiber liquid-phase microextraction and capillary zone electrophoresis.

    Science.gov (United States)

    da Silva, Gilmar Silvério; Lima, Diana L D; Esteves, Valdemar Inocêncio

    2017-06-01

    A low-cost methodology using hollow fiber liquid-phase microextraction (HF-LPME) and capillary zone electrophoresis (CZE) with UV-Vis detector was developed to analyze the salicylic acid (SA) in estuarine and riverine waters. The technique is easy-to-use and rapid, and demands little volume of organic solvent. The extraction was carried out using a polypropylene membrane supporting into octan-1-ol. HF-LPME under optimized conditions (donor solution sample pH 2, acceptor solution pH 14, sample volume 25 mL, fiber length 10 cm, acceptor volume 25 μL, extraction time 3 h and stirring speed 350 rpm) presented high enrichment factor (407 times) and good recovery in real water samples (from 88 to 110%). A limit of detection of 2.6 μg L -1 was achieved using CZE with UV-Vis detector as quantification method. The method was applied to direct quantification of SA in environmental complex estuarine and riverine water matrices.

  2. Investigation of maltodextrin-based synergistic system with amino acid chiral ionic liquid as additive for enantioseparation in capillary electrophoresis.

    Science.gov (United States)

    Chen, Jiaquan; Du, Yingxiang; Sun, Xiaodong

    2017-12-01

    The combined use of chiral ionic liquids (ILs) and chiral selectors in capillary electrophoresis (CE) to establish a synergistic system has proven to be an effective approach for enantioseparation. In this article, tetramethylammonium-L-arginine, a kind of amino acid chiral IL, was applied to investigate its potential synergistic effect with maltodextrin in CE enantioseparation. The established maltodextrin-based synergistic system showed markedly improved enantioseparations compared with the single maltodextrin system. Parameters such as the chiral IL concentration, maltodextrin concentration, buffer pH, applied voltage, and capillary temperature were optimized. Satisfactory enantioseparation of the five studied drugs, including nefopam, duloxetine, ketoconazole, cetirizine, and citalopram was achieved in 50 mM Tris-H 3 PO 4 buffer solution (pH 3.0) containing 7.0% (m/v) maltodextrin and 60 mM tetramethylammonium-L-arginine. In addition, the chiral configuration of tetramethylammonium-L-arginine was also investigated to demonstrate the existence of a synergistic effect between chiral ILs and maltodextrin. © 2017 Wiley Periodicals, Inc.

  3. Rapid and Simple Determination of Sarafloxacin and Difloxacin in Beef by Capillary Electrophoresis Coupled with Solid-Phase Extraction

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2018-01-01

    Full Text Available A simple and rapid capillary electrophoresis method with diode array detector was developed for determination of sarafloxacin and difloxacin in beef. In this study, the experimental parameters affecting the determination were systematically optimized, including wavelength, buffer system, pH and concentration, and separation temperature and voltage. Under the optimal conditions, sarafloxacin and difloxacin could be quantified within 4 min using H3BO3/Na2B4O7 buffer (35 mmol/L, pH 8.8 as background electrolyte, 25 kV as separation voltage, and 22°C as the column temperature. The linear range of the method was 1–20 μg/mL with LOD 0.8 μg/mL for sarafloxacin and 0.5–20 μg/mL with LOD 0.3 μg/mL for difloxacin. The RSDs for the peak area of 8 μg/mL sarafloxacin were 4.8% (intraday and 7.8% (interday, respectively. The proposed method has been applied to determine the residue of sarafloxacin and difloxacin in beef samples with the satisfactory recovery.

  4. The use of experimental design for the development of a capillary zone electrophoresis method for the quantitation of captopril.

    Science.gov (United States)

    Mukozhiwa, S Y; Khamanga, S M M; Walker, R B

    2017-09-01

    A capillary zone electrophoresis (CZE) method for the quantitation of captopril (CPT) using UV detection was developed. Influence of electrolyte concentration and system variables on electrophoretic separation was evaluated and a central composite design (CCD) was used to optimize the method. Variables investigated were pH, molarity, applied voltage and capillary length. The influence of sodium metabisulphite on the stability of test solutions was also investigated. The use of sodium metabisulphite prevented degradation of CPT over 24 hours. A fused uncoated silica capillary of 67.5cm total and 57.5 cm effective length was used for analysis. The applied voltage and capillary length affected the migration time of CPT significantly. A 20 mM phosphate buffer adjusted to pH 7.0 was used as running buffer and an applied voltage of 23.90 kV was suitable to effect a separation. The optimized electrophoretic conditions produced sharp, well-resolved peaks for CPT and sodium metabisulphite. Linear regression analysis of the response for CPT standards revealed the method was linear (R2 = 0.9995) over the range 5-70 μg/mL. The limits of quantitation and detection were 5 and 1.5 μg/mL. A simple, rapid and reliable CZE method has been developed and successfully applied to the analysis of commercially available CPT products.

  5. [Fast separation and analysis of water-soluble vitamins in spinach by capillary electrophoresis with high voltage].

    Science.gov (United States)

    Hu, Xiaoqin; You, Huiyan

    2009-11-01

    In capillary electrophoresis, 0-40 kV (even higher) voltage can be reached by a connecting double-model high voltage power supply. In the article, water-soluble vitamins, VB1, VB2, VB6, VC, calcium D-pantothenate, D-biotin, nicotinic acid and folic acid in vegetable, were separated by using the high voltage power supply under the condition of electrolyte water solution as running buffer. The separation conditions, such as voltage, the concentration of buffer and pH value etc. , were optimized during the experiments. The results showed that eight water-soluble vitamins could be baseline separated in 2.2 min at 40 kV applied voltage, 25 mmol/L sodium tetraborate buffer solution (pH 8.8). The water-soluble vitamins in spinach were quantified and the results were satisfied. The linear correlation coefficients of the water-soluble vitamins ranged from 0.9981 to 0.9999. The detection limits ranged from 0.2 to 0.3 mg/L. The average recoveries ranged from 88.0% to 100.6% with the relative standard deviations (RSD) range of 1.15%-4.13% for the spinach samples.

  6. Paulette Gray, Ph.D.

    Science.gov (United States)

    Paulette S. Gray, Ph.D. is the Director for the Division of Extramural Activities (DEA). As the director of the division, she is responsible for the overall scientific, fiscal, and administrative management of the division, including broad strategic planning, development, implementation, and evaluation.

  7. pH in Action

    NARCIS (Netherlands)

    Tijskens, L.M.M.; Biekman, E.S.A.

    2001-01-01

    Based on fundamental chemical relations, well-established in chemical engineering and chemical technology over almost a century, the effects of pH in food and agricultural products will be deduced for different situations and processes. Based on simple equilibria and dissociation of water, salts,

  8. Neuronal pH regulation

    DEFF Research Database (Denmark)

    Vorstrup, S; Jensen, K E; Thomsen, C

    1989-01-01

    The intracellular pH in the brain was studied in six healthy volunteers before and immediately after the administration of 2 g of acetazolamide. Phosphorus-31 nuclear magnetic resonance spectroscopy by a 1.5 tesla whole-body scanner was used. The chemical shift between the inorganic phosphate...

  9. Shift in genomic RNA patterns of human rotaviruses isolated from ...

    African Journals Online (AJOL)

    Rotalvirus-positive specimens from 322 infants and young children submitted to private patl1ology laboratories were analysed by polyacrylamide-gel electrophoresis of the viral RNA. A predominance of long RNA profiles occurred and a temporal shift in the genomic patterns was identified. An epidemic of the classic shorter ...

  10. High performance electrophoresis system for site-specific entrapment of nanoparticles in a nanoarray

    Science.gov (United States)

    Han, Jin-Hee; Lakshmana, Sudheendra; Kim, Hee-Joo; Hass, Elizabeth A.; Gee, Shirley; Hammock, Bruce D.; Kennedy, Ian

    2010-02-01

    A nanoarray, integrated with an electrophoretic system, was developed to trap nanoparticles into their corresponding nanowells. This nanoarray overcomes the complications of losing the function and activity of the protein binding to the surface in conventional microarrays by using minimum amounts of sample. The nanoarray is also superior to other biosensors that use immunoassays in terms of lowering the limit of detection to the femto- or atto-molar level. In addition, our electrophoretic particle entrapment system (EPES) is able to effectively trap the nanoparticles using a low trapping force for a short duration. Therefore, good conditions for biological samples conjugated with particles can be maintained. The channels were patterned onto a bi-layer consisting of a PMMA and LOL coating on conductive indium tin oxide (ITO)-coated glass slide by using e-beam lithography. The suspensions of 170 nm-nanoparticles then were added to the chip that was connected to a positive voltage. On top of the droplet, another ITO-coated-glass slide was covered and connected to a ground terminal. Negatively charged fluorescent nanoparticles (blue emission) were selectively trapped onto the ITO surface at the bottom of the wells by following electric field lines. Numerical modeling was performed by using commercially available software, COMSOL Multiphysics to provide better understanding about the phenomenon of electrophoresis in a nanoarray. Simulation results are also useful for optimally designing a nanoarray for practical applications.

  11. Application of preparative disk gel electrophoresis for antigen purification from inclusion bodies.

    Science.gov (United States)

    Okegawa, Yuki; Koshino, Masanori; Okushima, Teruya; Motohashi, Ken

    2016-02-01

    Specific antibodies are a reliable tool to examine protein expression patterns and to determine the protein localizations within cells. Generally, recombinant proteins are used as antigens for specific antibody production. However, recombinant proteins from mammals and plants are often overexpressed as insoluble inclusion bodies in Escherichia coli. Solubilization of these inclusion bodies is desirable because soluble antigens are more suitable for injection into animals to be immunized. Furthermore, highly purified proteins are also required for specific antibody production. Plastidic acetyl-CoA carboxylase (ACCase: EC 6.4.1.2) from Arabidopsis thaliana, which catalyzes the formation of malonyl-CoA from acetyl-CoA in chloroplasts, formed inclusion bodies when the recombinant protein was overexpressed in E. coli. To obtain the purified protein to use as an antigen, we applied preparative disk gel electrophoresis for protein purification from inclusion bodies. This method is suitable for antigen preparation from inclusion bodies because the purified protein is recovered as a soluble fraction in electrode running buffer containing 0.1% sodium dodecyl sulfate that can be directly injected into immune animals, and it can be used for large-scale antigen preparation (several tens of milligrams). Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Subtyping of Salmonella enterica isolated from humans and food animals using Pulsed-Field Gel Electrophoresis

    Directory of Open Access Journals (Sweden)

    Golab, N.

    2016-07-01

    Full Text Available Salmonella infections are the second leading cause of zoonotic bacterial foodborne illness. Main source of infection in human is contaminated food products. The aim of this study was sub typing isolates of Salmonella enterica obtained during our previous study by Pulsed Field Gel Electrophoresis (PFGE technique. All 46 Salmonella isolates were serotyped and then subjected to PFGE. Total isolates were analyzed by means of the molecular technique XbaI PFGE. In this study, PFGE and serotyping were used to subtype 46 Salmonella isolates belonging to 27different serovars and derived from human and different food origins. Among these isolates, S. Typhimurium was found to be the most predominant serovar. 40 PFGE patterns out of 46 isolates were obtained. The Discrimination Index obtained by serotyping (DI = 0.93 was lower than PFGE (DI = 0.99. Subtyping of Salmonella enterica is very important and shows that animal origin can be one of a reservoir that potentially could be transferred to human through the food chain. In addition, results of this study also revealed that this procedure is a golden standard for genotyping of such salmonella serotypes.

  13. Molecular Typing of Salmonella Isolates in Poultry by Pulsed-Field Gel Electrophoresis in Iran

    Directory of Open Access Journals (Sweden)

    Narges Golab

    2014-11-01

    Full Text Available Background: Salmonella is one of the most widespread zoonotic enter pathogenic microorganisms found in the global food chain. Poultryand Poultry products have been identified as one of the important foodborne sources of Salmonella. Pulsed-Field Gel Electrophoresis (PFGE is a gold standard typing method for identification of Salmonella isolates during outbreaks and epidemiological investigations. Objectives: The aim of this study was to carry out molecular typing of Salmonella enterica spp. by PFGE technique. Materials and Methods: All 47 Salmonella isolates were serotyped and then subjected to PFGE. Total isolates were analyzed by means of the molecular technique XbaI PFGE. Results: In the current work, PFGE and serotyping were used to subtype 47 Salmonella isolates belonging to 22 different serotypes and derived from poultry. Thirty-nine PFGE patterns out of 47 isolates were obtained. The Discrimination Index (DI by serotyping (0.93 was lower than PFGE (DI = 0.99. Conclusions: In conclusion, molecular methods such as PFGE can be used for epidemiological characterization of Salmonella serotypes.

  14. Capillary electrophoresis single-strand conformation polymorphism for the monitoring of gastrointestinal microbiota of chicken flocks.

    Science.gov (United States)

    Pissavin, C; Burel, C; Gabriel, I; Beven, V; Mallet, S; Maurice, R; Queguiner, M; Lessire, M; Fravalo, P

    2012-09-01

    The objective of the present study was to evaluate the capillary electrophoresis single-strand conformation polymorphism (CE-SSCP) to characterize poultry gut microbiota and the ability of this molecular method to detect modifications related to rearing conditions to be used as an epidemiological tool. The V3 region of the 16S rRNA gene was selected as the PCR target. Our results showed that this method provides reproducible data. The microbiota analysis of individuals showed that variability between individual fingerprints was higher for ileum and cloaca than for ceca. However, pooling the samples decreased this variability. To estimate the variability within and between farms, we compared molecular gut patterns of animals from the same hatchery reared under similar conditions and fed the same diet in 2 separate farms. Total aerobic bacteria, coliforms, and lactic acid bacteria were enumerated using conventional bacteriological methods. A significant difference was observed for coliforms present in the ceca and the cloaca depending on the farm. Ileal contents fingerprints were more closely related to those of cloacal contents than to those of ceca contents. When comparing samples from the 2 farms, a specific microbiota was highlighted for each farm. For each gut compartment, the microbiota fingerprints were joined in clusters according to the farm. Thus, this rapid and potentially high-throughput method to obtain gut flora fingerprints is sensitive enough to detect a "farm effect" on the balance of poultry gut microbiota despite the birds being fed the same regimens and reared under similar conditions.

  15. Bioanalysis of tobramycin for therapeutic drug monitoring by solid-phase extraction and capillary zone electrophoresis.

    Science.gov (United States)

    Fonge, Humphrey; Kaale, Eliangiringa; Govaerts, Cindy; Desmet, Koenraad; Van Schepdael, Ann; Hoogmartens, Jos

    2004-10-25

    A method based on solid-phase extraction (SPE) and capillary zone electrophoresis (CZE) for the analysis of tobramycin in human serum is presented. An off-line SPE employing a carboxypropyl bonded phase (CBA) cartridge was used for the extraction of tobramycin from human serum. Adsorbed tobramycin was eluted from the CBA cartridge using a mixture of NH(3) (25%, w/v)-methanol (30:70, v/v). After evaporation, the analyte was reconstituted and derivatized with o-phthaldialdehyde (OPA)/3-mercaptopropionic acid (MPA). The resulting tobramycin-OPA/MPA derivative was purified, and then identified by mass spectrometry. The tobramycin-OPA/MPA derivative was then analysed by CZE with a background electrolyte (BGE) comprising of 30 mM sodium tetraborate pH 10.0-acetonitrile (ACN) (80:20, v/v) with ultraviolet detection at 230 nm. A linear response was observed in the range of 0.3-30 microg/ml with r(2) = 0.992. The sensitivity of the method was determined by its limit of quantitation (LOQ) and limit of detection (LOD) of 0.3 microg/ml and 0.1 microg/ml, respectively. SPE recovery ranged from 68 to 79% at the trough levels to 98% at the peak levels found in serum. Furosemide has been added as internal standard (IS) to improve precision. For the therapeutic range of tobramycin in serum (2-10 microg/ml) the relative standard deviation (R.S.D.) was less than 11% for the entire SPE/CE process. The method demonstrated excellent selectivity as shown by the lack of interference from a total of 20 drugs investigated. The method was then used in therapeutic drug monitoring of patients receiving the drug.

  16. Determination of 2-methylimidazole and 4-methylimidazole in caramel colors by capillary electrophoresis.

    Science.gov (United States)

    Petruci, João Flávio da Silveira; Pereira, Elisabete Alves; Cardoso, Arnaldo Alves

    2013-03-06

    The use of chemical preservative compounds is common in the food products industry. Caramel color is the most usual additive used in beverages, desserts, and breads worldwide. During its fabrication process, 2- and 4-methylimidazole (MeI), highly carcinogenic compounds, are generated. In these cases, the development of reliable analytical methods for the monitoring of undesirable compounds is necessary. The primary procedure for the analysis of 2- and 4-MeI is using LC- or GC-MS techniques. These procedures are time-consuming and require large amounts of organic solvents and several pretreatment steps. This prevents the routine use of this procedure. This paper describes a rapid, efficient, and simple method using capillary electrophoresis (CE) for the separation and determination of 2- and 4-MeI in caramel colors. The analyses were performed using a 75 μm i.d. uncoated fused-silica capillary with an effective length of 40 cm and a running electrolyte consisting of 160 mmol L(-1) phosphate plus 30% acetonitrile. The pH was adjusted to 2.5 with triethylamine. The analytes were separated within 6 min at a voltage of 20 kV. Method validation revealed good repeatability of both migration time (<0.8% RSD) and peak area (<2% RSD). Analytical curves for 2- and 4-MeI were linear in the 0.4-40 mg L(-1) concentration interval. Detection limits were 0.16 mg L(-1) for 4-MeI and 0.22 mg L(-1) for 2-MeI. The extraction recoveries were satisfactory. The developed method showed many advantages when compared to the previously used method.

  17. Determination of lipoic acid in human urine by capillary zone electrophoresis.

    Science.gov (United States)

    Kubalczyk, Paweł; Głowacki, Rafał

    2017-07-01

    Fast, simple, and accurate CE method enabling determination of lipoic acid (LA) in human urine has been developed and validated. LA is a disulfide-containing natural compound absorbed from the organism's diet. Due to powerful antioxidant activity, LA has been used for prevention and treatment of various diseases and disorders, e.g. cardiovascular diseases, neurodegenerative disorders, and cancer. The proposed analytical procedure consists of liquid-liquid sample extraction, reduction of LA with tris(2-carboxyethyl)phosphine, derivatization with 1-benzyl-2-chloropyridinium bromide (BCPB) followed by field amplified sample injection stacking, capillary zone electrophoresis separation, and ultraviolet-absorbance detection of LA-BCPB derivative at 322 nm. Effective baseline electrophoretic separation was achieved within 6 min under the separation voltage of 20 kV (∼80 μA) using a standard fused-silica capillary (effective length 51.5 cm, 75 μm id) and BGE consisted of 0.05 mol/L borate buffer adjusted to pH 9. The experimentally determined limit of detection for LA in urine was 1.2 μmol/L. The calibration curve obtained for LA in urine showed linearity in the range 2.5-80 μmol/L, with R 2 0.9998. The relative standard deviation of the points of the calibration curve was lower than 10%. The analytical procedure was successfully applied to analysis of real urine samples from seven healthy volunteers who received single 100 mg dose of LA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Determination of ethyl sulfate in human serum and urine by capillary zone electrophoresis.

    Science.gov (United States)

    Jung, Balthasar; Caslavska, Jitka; Thormann, Wolfgang

    2008-10-03

    The use of capillary zone electrophoresis (CZE) with indirect absorbance detection for the analysis of ethyl sulfate (EtS) in serum and urine was investigated. EtS is a direct metabolite of ethanol employed as marker for recent alcohol consumption. Fused-silica capillaries of 60 cm total length were either coated with cetyltrimethylammonium bromide (CTAB, 50 microm I.D. capillary) or poly(diallyldimethylammonium chloride) (PDADMAC, 100 microm I.D. capillary) to allow CZE analyses to be performed with reversed polarity. At pH 2.2 with a maleic acid/phthalic acid background electrolyte, both approaches provided reliable EtS serum levels down to 0.2 mg L(-1) (1.6 microM) for the analysis of solid-phase extracts that were prepared after chloride precipitation. Analysis of urines diluted to a conductivity of 5 S m(-1) and analyzed in the two capillary formats resulted in limits of quantification (LOQs) of 2 and 1 mg L(-1), respectively. With urines adjusted to 10 S m(-1) via dilution or condensation, an LOQ of 0.6 mg L(-1) (4.8 microM) was obtained in the CTAB coated capillary whereas in the PDADMAC-coated capillary of equal length not all matrix components were resolved from EtS. The developed assays are robust and suitable to monitor EtS in samples of individuals who consumed as little as one standard drink of an alcoholic beverage containing about 14 g of ethanol.

  19. Automated dual capillary electrophoresis system with hydrodynamic injection for the concurrent determination of cations and anions

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Thi Thanh Thuy; Mai, Thanh Duc [University of Basel, Department of Chemistry, Spitalstrasse 51, Basel 4056 (Switzerland); Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi (Viet Nam); Nguyen, Thanh Dam [Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi (Viet Nam); Sáiz, Jorge [Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering – University of Alcalá, Ctra. Madrid-Barcelona km 33.6, Alcalá de Henares, Madrid 28871 (Spain); Pham, Hung Viet, E-mail: phamhungviet@hus.edu.vn [Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi (Viet Nam); Hauser, Peter C., E-mail: Peter.Hauser@unibas.ch [University of Basel, Department of Chemistry, Spitalstrasse 51, Basel 4056 (Switzerland)

    2014-09-02

    Highlights: • Concurrent determination of cations and anions was carried out by electrophoretic separation. • Optimized conditions for each class of analystes was possible by using separate capillaries. • Simultaneous hydrodynamic injection was carried out. • Pneumatic actuation was used for flushing and sample handling. • The denitrification of drinking water was successfully demonstrated. - Abstract: The capillary electrophoresis instrument developed for the concurrent determination of cations and anions features two separate capillaries and individual detectors to allow independent optimization for each group of ions. The capillaries are joined in a common injector block. The sample is drawn into the injector with a small membrane pump and automated simultaneous injection into both capillaries is achieved by pressurization of the fluid with compressed air. Flushing of the injector and of the capillaries with the background electrolyte is also carried out automatically by the same means. The buffer consisted of 12 mM histidine and 2 mM 18-crown-6 adjusted to pH 4 with acetic acid and was suitable for the contactless conductivity detection employed. The system was optimized for the determination of cationic NH{sub 4}{sup +} and anionic NO{sub 3}{sup −} and NO{sub 2}{sup −}, and linear calibration curves from about 20 μM up to about 1.5 mM were obtained for these ions. In a test run over 8 h, the reproducibility for the peak areas was within ±7%. For demonstration, the instrument was successfully applied to the concurrent monitoring of the concentrations of the three ions during the biological removal of ammonium from contaminated groundwater in a sequencing batch reactor, where NO{sub 3}{sup −} and NO{sub 2}{sup −} are formed as intermediate products.

  20. Chiral discrimination of sibutramine enantiomers by capillary electrophoresis and proton nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Lee, Yong-Jae; Choi, Seungho; Lee, Jinhoo; Nguyen, NgocVan Thi; Lee, Kyungran; Kang, Jong Seong; Mar, Woongchon; Kim, Kyeong Ho

    2012-03-01

    Capillary electrophoresis (CE) and proton nuclear magnetic resonance spectroscopy ((1)H-NMR) have been used to discriminate the enantiomers of sibutramine using cyclodextrin derivatives. Possible correlation between CE and (1)H-NMR was examined. Good correlation between the (1)H-NMR shift non-equivalence data for sibutramine and the degree of enantioseparation in CE was observed. In CE study, a method of enantiomeric separation and quantitation of sibutramine was developed using enantiomeric standards. The method was based on the use of 50 mM of phosphate buffer of pH 3.0 with 10 mM of methyl-beta-cyclodextrin (M-β-CD). 0.05% of LOD, 0.2% of LOQ for S-sibutramine enantiomer was achieved, and the method was validated and applied to the quantitative determination of sibutramine enantiomers in commercial drugs. On a 600 MHz (1)H-NMR analysis, enantiomer signal separation of sibutramine was obtained by fast diastereomeric interaction with a chiral selector M-β-CD. For chiral separation and quantification, N-methyl proton peaks (at 2.18 ppm) were selected because of its being singlet and simple for understanding of diastereomeric interaction. Effects of temperature and concentration of chiral selector on enantiomer signal separation were investigated. The optimum condition was 0.5 mg/mL of sibutramine and 10 mg/mL of M-β-CD at 10°C. Distinguishment of 0.5% of S-sibutramine in R-sibutramine was found to be possible by (1)H-NMR with M-β-CD as chiral selector. Host-guest interaction between sibutramine and M-β-CD was confirmed by (1)H-NMR studies and CE studies. A Structure of the inclusion complex was proposed considering (1)H-NMR and 2D ROESY studies.

  1. An Improved 2-Dimensional Gel Electrophoresis Method for Resolving Human Erythrocyte Membrane Proteins.

    Science.gov (United States)

    Kumar, Manoj; Singh, Rajendra; Meena, Anil; Patidar, Bhagwan S; Prasad, Rajendra; Chhabra, Sunil K; Bansal, Surendra K

    2017-01-01

    The 2-dimensional gel electrophoresis (2-DE) technique is widely used for the analysis of complex protein mixtures extracted from biological samples. It is one of the most commonly used analytical techniques in proteomics to study qualitative and quantitative protein changes between different states of a cell or an organism (eg, healthy and diseased), conditionally expressed proteins, posttranslational modifications, and so on. The 2-DE technique is used for its unparalleled ability to separate thousands of proteins simultaneously. The resolution of the proteins by 2-DE largely depends on the quality of sample prepared during protein extraction which increases results in terms of reproducibility and minimizes protein modifications that may result in artifactual spots on 2-DE gels. The buffer used for the extraction and solubilization of proteins influences the quality and reproducibility of the resolution of proteins on 2-DE gel. The purification by cleanup kit is another powerful process to prevent horizontal streaking which occurs during isoelectric focusing due to the presence of contaminants such as salts, lipids, nucleic acids, and detergents. Erythrocyte membrane proteins serve as prototypes for multifunctional proteins in various erythroid and nonerythroid cells. In this study, we therefore optimized the selected major conditions of 2-DE for resolving various proteins of human erythrocyte membrane. The modification included the optimization of conditions for sample preparation, cleanup of protein sample, isoelectric focusing, equilibration, and storage of immobilized pH gradient strips, which were further carefully examined to achieve optimum conditions for improving the quality of protein spots on 2-DE gels. The present improved 2-DE analysis method enabled better detection of protein spots with higher quality and reproducibility. Therefore, the conditions established in this study may be used for the 2-DE analysis of erythrocyte membrane proteins for

  2. Speciation of the plutonium at trace levels by capillary electrophoresis-ICP-MS coupling

    International Nuclear Information System (INIS)

    Ambard, Ch.

    2007-01-01

    The CE-ICP-MS coupling allowed the development of new analytical methods for the study of plutonium (Pu) speciation at trace levels including complexation studies of this element by organic and inorganic ligands. First, a method, called dual detection, based on the simultaneous use of the UV-Visible spectrophotometer integrated in the capillary electrophoresis and the ICP-MS was developed and validated. It allows the unambiguous determination of electrophoretic mobilities for separated chemical species and gives a powerful tool for speciation studies. Then, the influence on Pu redox speciation of the buffer from the background electrolyte was evaluated. This study showed the implications of the electrolyte constituents' choice on Pu redox equilibrium in the sample. Furthermore, the CE-ICP-MS coupling was used for studying the Pu complexation at trace levels by some organic (NTA and DTPA) and inorganic ligands (carbonates). The behaviour of Pu valence +III, +IV and +VI was studied in the presence of buffer at near neutral pH. Different species of Pu were observed depending on the initial oxidation state of the plutonium. The study showed the potential of poly-amino-carboxylic acids, such as NTA and DTPA, for dissolving Pu precipitates, regardless its initial speciation. Finally, the carbonation of pentavalent neptunium, as an analogue of Pu(V), was achieved at very low concentration of Np (10 -8 mol.L -1 ). The formation of NpO 2 (CO 3 ) - at 25 C and 2,5*10 -2 mol.L -1 ionic strength was measured by CE-ICP-MS and found to consistent with literature data. (author)

  3. Speciation of the plutonium at trace levels by capillary electrophoresis-ICP-MS coupling

    International Nuclear Information System (INIS)

    Ambard, Ch.

    2007-01-01

    The CE-ICP-MS coupling allowed the development of new analytical methods for the study of plutonium speciation at trace levels including complexation studies of this element by organic and inorganic ligands. First, a method, called dual detection, based on the simultaneous use of the UV-Visible spectrophotometer integrated in the capillary electrophoresis and the ICPMS was developed and validated. It allows the unambiguous determination of electrophoretic mobilities for separated chemical species and gives a powerful tool for speciation studies. Then, the influence on plutonium redox speciation of the buffer from the background electrolyte was evaluated. This study showed the implications of the electrolyte constituents' choice on plutonium redox equilibrium in the sample. Furthermore, the CE-ICP-MS coupling was used for studying the plutonium complexation at trace levels by some organic (NTA and DTPA) and inorganic ligands (carbonates). The behaviour of plutonium valence +III, +IV and +VI was studied in the presence of buffer at near neutral pH. Different species of plutonium were observed depending on the initial oxidation state of the plutonium. This study showed the potential of poly-amino-carboxylic acids, such as NTA and DTPA, for dissolving plutonium precipitates, regardless its initial speciation. Finally, the carbonation of pentavalent neptunium, as an analogue of Pu(V), was achieved at very low concentration of Np (10 -8 mol.L -1 ). The formation constant of NpO 2 (CO 3 )- at 25 deg. C and 2,5 x 10 -2 mol.L -1 ionic strength was measured by CE-ICP-MS and found to be consistent with literature data. (author)

  4. Epidemiologic analysis of sporadic Salmonella typhi isolates and those from outbreaks by pulsed-field gel electrophoresis.

    Science.gov (United States)

    Thong, K L; Cheong, Y M; Puthucheary, S; Koh, C L; Pang, T

    1994-05-01

    Pulsed-field gel electrophoresis (PFGE) was used to compare and analyze 158 isolates of Salmonella typhi from five well-defined outbreaks of typhoid fever in Malaysia and also isolates involved in sporadic cases of typhoid fever occurring during the same period. Digestion of chromosomal DNAs from these S. typhi isolates with the restriction endonucleases XbaI (5'-TCTAGA-3'), SpeI (5'-ACTAGT-3'), and AvrII (5'-CCTAGG-3') and then PFGE produced restriction endonuclease analysis (REA) patterns consisting of 11 to 24 DNA fragments ranging in size from 20 to 630 kbp. Analysis of the REA patterns generated by PFGE after digestion with XbaI and SpeI indicated that the S. typhi isolates obtained from sporadic cases of infection were much more heterogeneous (at least 13 different REA patterns were detected; Dice coefficient, between 0.73 and 1.0) than those obtained during outbreaks of typhoid fever. The clonal nature and the close genetic identities of isolates from outbreaks in Alor Setar, Penang, Kota Kinabalu, Johor Bahru, and Kota Bahru were suggested by the fact that only a limited number of REA patterns, which mostly differed by only a single band, were detected (one to four patterns; Dice coefficient, between 0.82 and 1.0), although a different pattern was associated with each of these outbreaks. Comparison of REA patterns with ribotyping for 18 S. typhi isolates involved in sporadic cases of infection showed a good correlation, in that 72% of the isolates were in the same group. There was no clear correlation of phage types with a specific REA pattern. We conclude that PFGE of s. typhi chromosomal DNA digested with infrequently cutting restriction endonucleases is a useful method for comparing and differentiating S. typhi isolates for epidemiological purposes.

  5. Large abnormal peak on capillary zone electrophoresis due to contrast agent.

    Science.gov (United States)

    Wheeler, Rachel D; Zhang, Liqun; Sheldon, Joanna

    2017-01-01

    Background Some iodinated radio-contrast media absorb ultraviolet light and can therefore be detected by capillary zone electrophoresis. If seen, these peaks are typically small with 'quantifications' of below 5 g/L. Here, we describe the detection of a large peak on capillary zone electrophoresis that was due to the radio-contrast agent, Omnipaque™. Methods Serum from a patient was analysed by capillary zone electrophoresis, and the IgG, IgA, IgM and total protein concentrations were measured. The serum sample was further analysed by gel electrophoresis and immunofixation. Results Capillary zone electrophoresis results for the serum sample showed a large peak with a concentration high enough to warrant urgent investigation. However, careful interpretation alongside the serum immunoglobulin concentrations and total protein concentration showed that the abnormal peak was a pseudoparaprotein rather than a monoclonal immunoglobulin. This was confirmed by analysis with gel electrophoresis and also serum immunofixation. The patient had had a CT angiogram with the radio-contrast agent Omnipaque™; addition of Omnipaque™ to a normal serum sample gave a peak with comparable mobility to the pseudoparaprotein in the patient's serum. Conclusions Pseudoparaproteins can appear as a large band on capillary zone electrophoresis. This case highlights the importance of a laboratory process that detects significant electrophoretic abnormalities promptly and interprets them in the context of the immunoglobulin concentrations. This should avoid incorrect reporting of pseudoparaproteins which could result in the patient having unnecessary investigations.

  6. New separation and detection methods in capillary electrophoresis and ion chromatography for the analysis of ionic compounds

    International Nuclear Information System (INIS)

    Mayrhofer, K.

    1999-10-01

    The first part of the thesis deals with the simultaneous analysis of inorganic anions and organic acids in electrodeposition coatings with the co-electroosmotic capillary electrophoresis. The coating of workpieces, e.g. car bodies, by means of an electrodeposition process is an important methodology especially in the automotiv industries. It is usually performed by introducing the object into a basin filled with a water-based electro-dipcoat, applying a voltage of 200-400 Volts (direct current) and using the bodywork as cathode. Because the workpiece has to pass a number of preliminary treatments before the coating procedure, ionic compound may be carried into the basin. If the concentrations of these ionic impurities is too high, the electro-deposition of the binding agent fails or the thickness of the coating is not reproducible. The organic acids are used as neutralization agents in order to control and to keep the pH of the basin constant. The common method of analysing ionic impurities is ion chromatography. The organic acids have to be separated in an ion exclusion chromatography column because organic acids may coelute with the inorganic anions or elute with the dead volume. Therefore a separation method for capillary electrophoresis was developed which enables the simultaneouse analysis of inorganic anions and organic acids in less then 5 minutes. Chloride, nitrate, sulfate, fuoride, phosphate, carbonate, formic acid, acetic acid, lactic acid and butyric acid were detected with indirect UV-detection at 254 nm. For removal of the the binding agent and the pigments the lacquer was mixed with a 0.01 M sodium hydroxide solution and then filtered through a 0.45 μm filter cartridge. 5 mM trimellitic acid, titrated with sodium hydroxid to pH 10, 0.001 % hexadimethrinbromide and 20 % acetonitrile served as buffer. The analytes were separated with a satisfactory resolution. Between every analysis the fused silica capillary was purged for two minutes with buffer. So

  7. Communication and information-seeking behavior of PhD students in physicists and astronomy

    OpenAIRE

    Jamali, Hamid R.

    2006-01-01

    As a part of a wider doctoral research, this paper deals with the communication and information-seeking behavior of research (PhD) students in physics and astronomy. Based on a qualitative case study of PhD students in the Department of Physics and Astronomy at University College London, this study seeks to derive behavioral patterns in information-seeking activities of PhD students. The study aims to investigate the intradisciplinary differences in information-seeking activities of physicist...

  8. Comparison of Yeast Cell Protein Solubilization Procedures for Two-dimensional Electrophoresis

    DEFF Research Database (Denmark)

    Harder, A; Wildgruber, R; Nawrocki, A

    1999-01-01

    Three different procedures for the solubilization of yeast (S. cerevisiae) cell proteins were compared on the basis of the obtained two-dimensional (2-D) polypeptide patterns. Major emphasis was laid on minimizing handling steps, protein modification or degradation, and quantitative loss of high...... with sodium dodecyl sulfate (SDS) buffer, consisting of 1% SDS and 100 mM tris(hydroxymethyl)aminomethane (Tris)-HCl, pH 7.0, followed by dilution with "standard" lysis buffer, and (iii) boiling the sample with SDS during cell lysis, followed by dilution with thiourea/urea lysis buffer (2 M thiourea/ 7 M urea...

  9. Industrial PhD report: Sustainable Innovation

    DEFF Research Database (Denmark)

    Olesen, Gitte Gylling Hammershøj

    2011-01-01

    Erhvervs PhD rapport udarbejdet i tilknytning til Erhvervs PhD kurset der er obligatorisk for Erhvervs PhD studerende. Rapporten omhandler relationer melllem den akademiske verden og industrien i sammenhæng med PhD projektet, betragtet og analyseret gennem teori om bæredygtig innovation....

  10. Determination of Five Major 8-Prenylflavones in Leaves of Epimedium by Solid-Phase Extraction Coupled with Capillary Electrophoresis

    Science.gov (United States)

    Xie, Juan-ping; Xiang, Ji-ming; Zhu, Zhong-liang

    2016-01-01

    A simple, accurate and reproducible method which is based on the capillary electrophoresis, coupled with solid-phase extraction, has been developed for simultaneous determination of multiple 8-prenylflavones from Chinese Herba Epimedii. In this study, the author has mainly illustrated the experimental process and research results of five major components including epimedin C, icariin, diphylloside A, epimedoside A and icarisoside A that have been extracted and identified from Herba Epimedii for the first time. Experimental conditions have been optimized to achieve the best separation efficiency for the following factors: the buffer pH, buffer concentration and applied voltage. The experiment can be conducted through two separable stages: the first stage is to obtain the crude extracts through the solid-phase extraction; and the second stage is to further separate five major components by using the capillary electrophoresis. The separation of the five components and the analysis of the experiment are relatively fast and can be completed within 20 min. The concentration ranges of the construction of standard curves of five major 8-prenylflavones are 32.0–395.0, 23.4–292.0, 42.1–526.0, 18.8–233.5 and 29.7–371.0 µg mL−1 respectively, which have showed acceptable linearity with a correlation coefficient, r ≥ 0.999. The coefficient varies within 2.0% for both intra- and inter-days tests. The recoveries of five components range from 92.3 to 104.1%. The relative standard deviations of recoveries of five components range from 1.2 and 2.8%. This new method will facilitate the extraction and expedite the determination of medical components from Herba Epimedii. PMID:26865656

  11. Speciation and solubility of neptunium in underground environments by paper electrophoresis

    International Nuclear Information System (INIS)

    Nagasaki, S.; Tanaka, Satoru; Takahashi, Yoichi

    1988-01-01

    Speciation and solubility of neptunium were studied using paper electrophoresis, ion exchange and ultrafiltration. Among these methods, the paper electrophoresis was found to be suitable for measuring speciation and solubility of neptunium of low concentration, if chemical species had opposite charge to each other or dissolved species had a charge. Using paper electrophoresis, hydrolysis constants of NpO 2 OH 0 and NpO 2 - (OH) 2 - and solubility product of NpO 2 were obtained and ionic-strength dependence of speciation was observed. (author) 9 refs.; 3 figs.; 2 tabs

  12. Mutation screening of the TP53 gene by temporal temperature gradient gel electrophoresis.

    Science.gov (United States)

    Sørlie, Therese; Johnsen, Hilde; Vu, Phuong; Lind, Guro Elisabeth; Lothe, Ragnhild; Børresen-Dale, Anne-Lise

    2005-01-01

    A protocol for detection of mutations in the TP53 gene using temporal temperature gradient gel electrophoresis (TTGE) is described. TTGE is a mutation detection technique that separates DNA fragments differing by single base pairs according to their melting properties in a denaturing gel. It is based on constant denaturing conditions in the gel combined with a temperature gradient during the electrophoretic run. This method combines some of the advantages of the related techniques denaturing gradient gel electrophoresis (DGGE) and constant denaturant gel electrophoresis (CDGE) and eliminates some of the problems. The result is a rapid and sensitive screening technique that is robust and easily set up in smaller laboratory environments.

  13. Mutation screening of the TP53 gene by temporal temperature gel electrophoresis (TTGE).

    Science.gov (United States)

    Sørlie, Therese; Johnsen, Hilde; Vu, Phuong; Lind, Guro Elisabeth; Lothe, Ragnhild; Børresen-Dale, Anne-Lise

    2014-01-01

    A protocol for detection of mutations in the TP53 gene using temporal temperature gradient electrophoresis (TTGE) is described. TTGE is a mutation detection technique that separates DNA fragments differing by single base pairs according to their melting properties in a denaturing gel. It is based on constant denaturing conditions in the gel combined with a temperature gradient during the electrophoretic run. This method combines some of the advantages of the related techniques, denaturing gradient gel electrophoresis and constant denaturant gel electrophoresis, and eliminates some of the problems. The result is a rapid and sensitive screening technique which is robust and easily set up in smaller laboratory environments.

  14. Medium pH in submerged cultivation modulates differences in the intracellular protein profile of Fusarium oxysporum.

    Science.gov (United States)

    da Rosa-Garzon, Nathália Gonsales; Laure, Hélen Julie; Souza-Motta, Cristina Maria de; Rosa, José César; Cabral, Hamilton

    2017-08-09

    Fusarium oxysporum is a filamentous fungus that damages a wide range of plants and thus causes severe crop losses. In fungal pathogens, the genes and proteins involved in virulence are known to be controlled by environmental pH. Here, we report the influence of culture-medium pH (5, 6, 7, and 8) on the production of degradative enzymes involved in the pathogenesis of F. oxysporum URM 7401 and on the 2D-electrophoresis profile of intracellular proteins in this fungus. F. oxysporum URM 7401 was grown in acidic, neutral, and alkaline culture media in a submerged bioprocess. After 96 hr, the crude extract was processed to enzyme activity assays, while the intracellular proteins were obtained from mycelium and analyzed using 2D electrophoresis and mass spectrometry. We note that the diversity of secreted enzymes was changed quantitatively in different culture-medium pH. Also, the highest accumulated biomass and the intracellular protein profile of F. oxysporum URM 7401 indicate an increase in metabolism in neutral-alkaline conditions. The differential profiles of secreted enzymes and intracellular proteins under the evaluated conditions indicate that the global protein content in F. oxysporum URM 7401 is modulated by extracellular pH.

  15. Analytical characterization of wine and its precursors by capillary electrophoresis.

    Science.gov (United States)

    Gomez, Federico J V; Monasterio, Romina P; Vargas, Verónica Carolina Soto; Silva, María F

    2012-08-01

    The accurate determination of marker chemical species in grape, musts, and wines presents a unique analytical challenge with high impact on diverse areas of knowledge such as health, plant physiology, and economy. Capillary electromigration techniques have emerged as a powerful tool, allowing the separation and identification of highly polar compounds that cannot be easily separated by traditional HPLC methods, providing complementary information and permitting the simultaneous analysis of analytes with different nature in a single run. The main advantage of CE over traditional methods for wine analysis is that in most cases samples require no treatment other than filtration. The purpose of this article is to present a revision on capillary electromigration methods applied to the analysis of wine and its precursors over the last decade. The current state of the art of the topic is evaluated, with special emphasis on the natural compounds that have allowed wine to be considered as a functional food. The most representative revised compounds are phenolic compounds, amino acids, proteins, elemental species, mycotoxins, and organic acids. Finally, a discussion on future trends of the role of capillary electrophoresis in the field of analytical characterization of wines for routine analysis, wine classification, as well as multidisciplinary aspects of the so-called "from soil to glass" chain is presented. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Pencil graphite leads as simple amperometric sensors for microchip electrophoresis.

    Science.gov (United States)

    Natiele Tiago da Silva, Eiva; Marques Petroni, Jacqueline; Gabriel Lucca, Bruno; Souza Ferreira, Valdir

    2017-11-01

    In this work we demonstrate, for the first time, the use of inexpensive commercial pencil graphite leads as simple amperometric sensors for microchip electrophoresis. A PDMS support containing one channel was fabricated through soft lithography and sanded pencil graphite leads were inserted into this channel to be used as working electrodes. The electrochemical and morphological characterization of the sensor was carried out. The graphite electrode was coupled to PDMS microchips in end-channel configuration and electrophoretic experiments were performed using nitrite and ascorbate as probe analytes. The analytes were successfully separated and detected in well-defined peaks with satisfactory resolution using the microfluidic platform proposed. The repeatability of the pencil graphite electrode was satisfactory (RSD values of 1.6% for nitrite and 12.3% for ascorbate, regarding the peak currents) and its lifetime was estimated to be ca. 700 electrophoretic runs over a cost of ca. $ 0.05 per electrode. The limits of detection achieved with this system were 2.8 μM for nitrite and 5.7 μM for ascorbate. For proof of principle, the pencil graphite electrode was employed for the real analysis of well water samples and nitrite was successfully quantified at levels below its maximum contaminant level established in Brazil and US. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Integration of capillary electrophoresis with gold nanoparticle-based colorimetry.

    Science.gov (United States)

    Li, Tong; Wu, Zhenglong; Qin, Weidong

    2017-12-01

    A method integrating capillary electrophoresis (CE) and gold nanoparticle aggregation-based colorimetry (AuNP-ABC) was described. By using a dual-sheath interface, the running buffer was isolated from the colorimetric reaction solution so that CE and AuNP-ABC would not interfere with each other. The proof-of-concept was validated by assay of polyamidoamine (PAMAM) dendrimers that were fortified in human urine samples. The factors influencing the CE-AuNP-ABC performances were investigated and optimized. Under the optimal conditions, the dendrimers were separated within 8 min, with detection limits of 0.5, 1.2 and 2.6 μg mL -1 for PAMAM G1.0, G2.0 and G3.0, respectively. The sensitivity of CE-AuNP-ABC was comparable to or even better than those of liquid chromatography-fluorimetry and liquid chromatography-mass spectrometry. The results suggested that the proposed strategy can be applied to facile and quick determination of analytes of similar properties in complex matrices. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Studies on irradiated lactate dehydrogenase using gel electrophoresis

    International Nuclear Information System (INIS)

    Huth, O.

    1981-01-01

    LDH in aqueous phosphate buffer solution was x-irradiated under nitrogen and dinitrogen oxide. The pre-treated samples were separated by SDS-phosphate gel electrophoresis. Colour yields of the protein bands were determined by planimetry following staining and photometric densitometry. It could be shown that aggregates formed up to the tetramer size were mainly covalently bonded and that negligent amounts of fragments are formed. No exact statements could be made concerning products formed after longer irradiation treatment. Measurements under UV-light also revealed an elevated base from the point of application to the band at the native LDH level; this supports the theory of a reduced migration path through intra-molecular bonding. No firm conclusions can be drawn from the process of staining because CBB itself leads to an increased background colouring between closely-lying protein bands. It could be shown that OH-radicals cause greater changes than H-radicals or solvated electrons since the native LDH peak diminished fastest when irradiated under dinitrogen oxide. With regard to radiation effect it could be demonstrated that a higher radiation dose was required for degradation of the LDH molecule than for its inactivation. These values approach each other with increasing concentration. This indicates that at low concentrations inactivation of the enzyme is mainly caused by conformational changes and at high concentrations by aggregation. Disulphide bridges were found to contribute to aggregate formation in 5-15% of the aggregates formed, this increasing linearly with concentration. (orig./MG) [de

  19. Analysis of results of ASTP experiment in electrophoresis

    Science.gov (United States)

    Vanderhoff, J. W.; Micale, F. J.; Krumrine, P. H.

    1977-01-01

    The Apollo-Soyuz Test Project (ASTP) included an electrophoretic separation experiment of biological cells. The nature separation results of aldehyde-fixed rabbit, human and horse red blood cells, which were taken in the form of photographs taken at three-minute intervals, are the subject of this report. The electrophoretic separation was successful in that fractionation according to mobility did occur and was found in the sliced samples. Photographic evidence indicates that the low electroosmotic methylcellulose coating was successful in reducing the electroosmosis to a near zero value. Also, the flight film shows that the bands migrated down the column as theory would predict, producing two bands of high cell concentration separated and surrounded by regions of lower cell concentration. However, most likely some clumping of cells occurred to cause the trailing band to be larger than expected from theory. Overall, the experiment was a success in demonstrating a static electrophoresis separation under microgravity conditions with a resolution not possible on earth.

  20. Quantification of carbamylated albumin in serum based on capillary electrophoresis.

    Science.gov (United States)

    Delanghe, Sigurd; Moerman, Alena; Pletinck, Anneleen; Schepers, Eva; Glorieux, Griet; Van Biesen, Wim; Delanghe, Joris R; Speeckaert, Marijn M

    2017-09-01

    Protein carbamylation, a nonenzymatic posttranslational modification promoted during uremia, is linked to a poor prognosis. In the present study, carbamylation of serum albumin was assayed using the symmetry factor on a capillary electrophoresis instrument (Helena V8). The symmetry factor has been defined as the distance from the center line of the peak to the back slope, divided by the distance from the center line of the peak to the front slope, with all measurements made at 10% of the maximum peak height. Serum albumin, creatinine, and urea concentrations were assayed using routine methods, whereas uremic toxins were determined using HPLC. In vitro carbamylation induced a marked albumin peak asymmetry. Reference values for the albumin symmetry factor were 0.69-0.92. In kidney patients, albumin peak asymmetry corresponded to the chronic kidney disease stage (p < 0.0001). The symmetry factor correlated well with serum urea (r = -0.5595, p < 0.0001) and creatinine (r = -0.5986, p < 0.0001) concentrations. Several protein-bound uremic toxins showed a significant negative correlation with the symmetry factor. Morphology of the albumin fraction was not affected by presence of glycated albumin and protein-bound antibiotics. In conclusion, the presented method provides a simple, practical way for monitoring protein carbamylation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. A versatile electrophoresis-based self-test platform.

    Science.gov (United States)

    Staal, Steven; Ungerer, Mathijn; Floris, Arjan; Ten Brinke, Hans-Willem; Helmhout, Roy; Tellegen, Marian; Janssen, Kjeld; Karstens, Erik; van Arragon, Charlotte; Lenk, Stefan; Staijen, Erik; Bartholomew, Jody; Krabbe, Hans; Movig, Kris; Dubský, Pavel; van den Berg, Albert; Eijkel, Jan

    2015-03-01

    This paper reports on recent research creating a family of electrophoresis-based point of care devices for the determination of a wide range of ionic analytes in various sample matrices. These devices are based on a first version for the point-of-care measurement of Li(+), reported in 2010 by Floris et al. (Lab Chip 2010, 10, 1799-1806). With respect to this device, significant improvements in accuracy, precision, detection limit, and reliability have been obtained especially by the use of multiple injections of one sample on a single chip and integrated data analysis. Internal and external validation by clinical laboratories for the determination of analytes in real patients by a self-test is reported. For Li(+) in blood better precision than the standard clinical determination for Li(+) was achieved. For Na(+) in human urine the method was found to be within the clinical acceptability limits. In a veterinary application, Ca(2+) and Mg(2+) were determined in bovine blood by means of the same chip, but using a different platform. Finally, promising preliminary results are reported with the Medimate platform for the determination of creatinine in whole blood and quantification of both cations and anions through replicate measurements on the same sample with the same chip. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Detection of circular telomeric DNA without 2D gel electrophoresis.

    Science.gov (United States)

    Dlaska, Margit; Anderl, Conrad; Eisterer, Wolfgang; Bechter, Oliver E

    2008-09-01

    The end of linear chromosomes forms a lasso-like structure called the t-loop. Such t-loops resemble a DNA recombination intermediate, where the single-stranded 3' overhang is arrested in a stretch of duplex DNA. Presumably, such a t-loop can also be deleted via a recombination process. This would result in the occurrence of circular extrachromosomal telomeric DNA (t-circles), which are known to be abundantly present in immortal cells engaging the recombination-based alternative lengthening of telomeres pathway (ALT pathway). Little is known about the basic mechanism of telomeric recombination in these cells and what ultimately causes the generation of such t-circles. Current standard procedures for detecting these molecules involve 2D gel electrophoresis or electron microscopy. However, both methods are labor intense and sophisticated to perform. Here, we present a simpler, faster, and equally sensitive method for detecting t-circles. Our approach is a telomere restriction fragment assay that involves the enzymatic preservation of circular DNA with Klenow enzyme followed by Bal31 degradation of the remaining linear DNA molecules. We show that with this approach t-circles can be detected in ALT cell lines, whereas no t-circles are present in telomerase-positive cell lines. We consider our approach a valid method in which t-circle generation is the experimental readout.

  3. Capillary electrophoresis methods for microRNAs assays: A review

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Eunmi; Song, Eun Joo, E-mail: ejsong@kist.re.kr

    2014-12-10

    Highlights: • A review of CE analysis of miRNAs. • Summary of developments and applications of CE systems in miRNA studies. • Applications and development of microchip-based CE for rapid analysis of miRNA. - Abstract: MicroRNAs (miRNAs) are short noncoding RNAs that conduct important roles in many cellular processes such as development, proliferation, differentiation, and apoptosis. In particular, circulating miRNAs have been proposed as biomarkers for cancer, diabetes, cardiovascular disease, and other illnesses. Therefore, determination of miRNA expression levels in various biofluids is important for the investigation of biological processes in health and disease and for discovering their potential as new biomarkers and drug targets. Capillary electrophoresis (CE) is emerging as a useful analytical tool for analyzing miRNA because of its simple sample preparation steps and efficient resolution of a diverse size range of compounds. In particular, CE with laser-induced fluorescence detection is a promising and relatively rapidly developing tool with the potential to provide high sensitivity and specificity in the analysis of miRNAs. This paper covers a short overview of the recent developments and applications of CE systems in miRNA studies in biological and biomedical areas.

  4. Demonstrate use of capillary electrophoresis low level transient of anions

    International Nuclear Information System (INIS)

    Moum, Kari-Lye; Solheim, Torill; McElrath, Joel; Frattini, Paul

    2012-09-01

    Capillary Electrophoresis (CE) is a well-known analytical method capable of rapid detection of very low concentration of cations and anionic species such as chloride, sulfate and nitrate. These anions are of crucial importance in reducing the potential of stainless steel components to undergo stress corrosion cracking. Currently, Nuclear Power Plants (NPPs) use Ion Chromatography (IC) as the analytical technique to achieve the required detection levels of ionic species. At the Halden Reactor Project (HRP) IC was replaced by CE in 1996, and since then HRP has gained nearly 20 years of operational experience. During the last 15 years, EPRI has done research on the CE technique and has achieved extensive experience in this area. EPRI has demonstrated detection levels at ppt and sub-ppb levels. This paper presents the ability of the CE technique to follow low level transients of anions in Boiling Water Reactor (BWR) coolant. A transient caused by approx. 10 ppb chloride and sulfate was simulated in an experimental circuit simulating BWR conditions. A series of grab samples were taken and analysed using HRPs CE (Agilent G1600). (authors)

  5. Radiation-induced apoptosis in different pH environments in vitro

    International Nuclear Information System (INIS)

    Lee, Hyung-Sik; Park, Heon J.; Lyons, John C.; Griffin, Robert J.; Auger, Elizabeth A.; Song, Chang W.

    1997-01-01

    Purpose: The effect of environmental pH on the radiation-induced apoptosis in tumor cells in vitro was investigated. Methods and Materials: Mammary adenocarcinoma cells of A/J mice (SCK cells) were irradiated with γ-rays using a 137 Cs irradiator and incubated in media of different pHs. After incubation at 37 deg. C for 24-120 h the extent of apoptosis was determined using agarose gel electrophoresis, TdT-mediated dUTP-biotin nick end labeling (TUNEL) staining, flow cytometry, and release of 3 H from 3 H-thymidine labeled cells. The clonogenicity of the cells irradiated in different pH medium was determined, and the progression of cells through the cell cycle after irradiation in different pHs was also determined with flow cytometry. Results: Irradiation with 2-12 Gy of γ-rays induced apoptosis in SCK cells in pH 7.5 medium within 48 h as judged from the results of four different assays mentioned. Radiation-induced apoptosis declined as the medium pH was lowered from 7.5 to 6.4. Specifically, the radiation-induced degradation of DNA including the early DNA breaks, as determined with the TUNEL method, progressively declined as the medium pH was lowered so that little DNA fragmentation occurred 48 h after irradiation with 12 Gy in pH 6.6 medium. When the cells were irradiated and incubated for 48 h in pH 6.6 medium and the medium was replaced with pH 7.5 medium, DNA fragmentation promptly occurred. DNA fragmentation also occurred even in pH 6.6 medium when the cells were irradiated and maintained in pH 7.5 medium for 8 h or longer post-irradiation before incubation in pH 6.6 medium. The radiation-induced G 2 arrest in pH 6.6 medium lasted markedly longer than that in pH 7.5 medium. Conclusion: Radiation-induced apoptosis in SCK cells in vitro is reversibly suppressed in an acidic environment. Taking the results of four different assays together, it was concluded that early step(s) in the apoptotic pathway, probably the DNA break or upstream of DNA break, is

  6. Proteomics analysis of Fusarium proliferatum under various initial pH during fumonisin production.

    Science.gov (United States)

    Li, Taotao; Gong, Liang; Wang, Yong; Chen, Feng; Gupta, Vijai Kumar; Jian, Qijie; Duan, Xuewu; Jiang, Yueming

    2017-07-05

    Fusarium proliferatum as a fungal pathogen can produce fumonisin which causes a great threat to animal and human health. Proteomic approach was a useful tool for investigation into mycotoxin biosynthesis in fungal pathogens. In this study, we analyzed the fumonisin content and mycelium proteins of Fusarium proliferatum cultivated under the initial pH5 and 10. Fumonisin production after 10days was significantly induced in culture condition at pH10 than pH5. Ninety nine significantly differently accumulated protein spots under the two pH conditions were detected using two dimensional polyacrylamide gel electrophoresis and 89 of these proteins were successfully identified by MALDI-TOF/TOF and LC-ESI-MS/MS analysis. Among these 89 proteins, 45 were up-regulated at pH10 while 44 were up-accumulated at pH5. At pH10, these proteins were found to involve in the modification of fumonisin backbone including up-regulated polyketide synthase, cytochrome P450, S-adenosylmethionine synthase and O-methyltransferase, which might contribute to the induction of fumonisin production. At pH5, these up-regulated proteins such as l-amino-acid oxidase, isocitrate dehydrogenase and citrate lyase might inhibit the condensation of fumonisin backbone, resulting in reduced production of fumonisins. These results may help us to understand the molecular mechanism of the fumonisin synthesis in F. proliferatum. To extend our understanding of the mechanism of the fumonisin biosynthesis of F. proliferatum, we reported the fumonisin production in relation to the differential proteins of F. proliferatum mycelium under two pH culture conditions. Among these 89 identified spots, 45 were up-accumulated at pH10 while 44 were up-accumulated at pH5. Our results revealed that increased fumonisin production at pH10 might be related to the induction of fumonisin biosynthesis caused by up-regulation of polyketide synthase, cytochrome P450, S-adenosylmethionine synthase and O-methyltransferase. Meanwhile, the

  7. Electrophoretic deposition and field emission properties of patterned carbon nanotubes

    International Nuclear Information System (INIS)

    Zhao Haifeng; Song Hang; Li Zhiming; Yuan Guang; Jin Yixin

    2005-01-01

    Patterned carbon nanotubes on silicon substrates were obtained using electrophoretic method. The carbon nanotubes migrated towards the patterned silicon electrode in the electrophoresis suspension under the applied voltage. The carbon nanotubes arrays adhered well on the silicon substrates. The surface images of carbon nanotubes were observed by scanning electron microscopy. The field emission properties of the patterned carbon nanotubes were tested in a diode structure under a vacuum pressure below 5 x 10 -4 Pa. The measured emission area was about 1.0 mm 2 . The emission current density up to 30 mA/cm 2 at an electric field of 8 V/μm has been obtained. The deposition of patterned carbon nanotubes by electrophoresis is an alternative method to prepare field emission arrays

  8. Disparity between Multilocus Enzyme Electrophoresis, Microsatellite Markers and Pulsed-Field Gel Electrophoresis in epidemiological tracking of Candida albicans.

    Science.gov (United States)

    Boriollo, Marcelo Fabiano Gomes; Dias, Ricardo Antunes; Fiorini, João Evangelista; Oliveira, Nelma de Mello Silva; Spolidório, Denise Madalena Palomari; de Souza, Henrique Marques Barbosa; Figueira, Antonio Vargas de Oliveira; Pizzirani-Kleiner, Aline Aparecida

    2010-09-01

    Various molecular systems are available for epidemiological, genetic, evolutionary, taxonomic and systematic studies of innumerable fungal infections, especially those caused by the opportunistic pathogen C. albicans. A total of 75 independent oral isolates were selected in order to compare Multilocus Enzyme Electrophoresis (MLEE), Electrophoretic Karyotyping (EK) and Microsatellite Markers (Simple Sequence Repeats - SSRs), in their abilities to differentiate and group C. albicans isolates (discriminatory power), and also, to evaluate the concordance and similarity of the groups of strains determined by cluster analysis for each fingerprinting method. Isoenzyme typing was performed using eleven enzyme systems: Adh, Sdh, M1p, Mdh, Idh, Gdh, G6pdh, Asd, Cat, Po, and Lap (data previously published). The EK method consisted of chromosomal DNA separation by pulsed-field gel electrophoresis using a CHEF system. The microsatellite markers were investigated by PCR using three polymorphic loci: EF3, CDC3, and HIS3. Dendrograms were generated by the SAHN method and UPGMA algorithm based on similarity matrices (S(SM)). The discriminatory power of the three methods was over 95%, however a paired analysis among them showed a parity of 19.7-22.4% in the identification of strains. Weak correlation was also observed among the genetic similarity matrices (S(SM)(MLEE)xS(SM)(EK)xS(SM)(SSRs)). Clustering analyses showed a mean of 9+/-12.4 isolates per cluster (3.8+/-8 isolates/taxon) for MLEE, 6.2+/-4.9 isolates per cluster (4+/-4.5 isolates/taxon) for SSRs, and 4.1+/-2.3 isolates per cluster (2.6+/-2.3 isolates/taxon) for EK. A total of 45 (13%), 39 (11.2%), 5 (1.4%) and 3 (0.9%) clusters pairs from 347 showed similarity (S(J)) of 0.1-10%, 10.1-20%, 20.1-30% and 30.1-40%, respectively. Clinical and molecular epidemiological correlation involving the opportunistic pathogen C. albicans may be attributed dependently of each method of genotyping (i.e., MLEE, EK, and SSRs) supplemented

  9. Design and Fabrication of 3D-Structured Contactless Capacitive-Type Detector for Capillary Electrophoresis Microchip

    International Nuclear Information System (INIS)

    Lee, C-Y; Lin, C-H; Fu, L-M

    2006-01-01

    Using simple and reliable microfabrication techniques, this study develops a capillary electrophoresis (CE) microchip with 3-dimensional-structured (3D-structured) contactless capacitive detector electrodes mounted parallel to the separation channel. The offchannel electrodes are deposited by Au sputtering and patterned using a standard 'lift-off' process. A vacuum fusion bonding process is employed to seal the lower substrate containing the microchannels and electrodes to an upper glass cover plate. The variation in the capacitance between the electrodes in the side channels is measured as different samples and ions pass through the detection region of the CE separation channel. Samples of Rhodamine B and a commercial sports drink are mixed in different buffer solutions and successfully separated and detected using the developed device. The 3D-structured contactless capacitive-type detection device has microscale dimensions and provides a valuable contribution to the realization of the lab-on-a-chip concept

  10. An interlaboratory comparison of ITS2-PCR for the identification of yeasts, using the ABI Prism 310 and CEQ8000 capillary electrophoresis systems

    Directory of Open Access Journals (Sweden)

    Verschraegen Gerda

    2005-03-01

    Full Text Available Abstract Background Currently, most laboratories identify yeasts routinely on the basis of morphology and biochemical reactivity. This approach has quite often limited discriminatory power and may require long incubation periods. Due to the increase of fungal infections and due to specific antifungal resistence patterns for different species, accurate and rapid identification has become more important. Several molecular techniques have been described for fast and reliable identification of yeast isolates, but interlaboratory exchangeability of identification schemes of molecular techniques has hardly been studied. Here, we compared amplified ITS2 fragment length determination by an ABI Prism 310 (Applied Biosystems, Foster City, Ca. capillary electrophoresis system with that obtained by a CEQ8000 (Beckman Coulter, Fullerton, Ca. capillary electrophoresis system. Results Although ITS2 size estimations on both systems differed and separate libraries had to be constructed for each system, both approaches had the same discriminatory power with regard to the 44 reference strains, identical identifications were obtained for 39/ 40 clinical isolates in both laboratories and strains from 51 samples were correctly identified using CEQ8000, when compared to phenotypic identification. Conclusion Identification of yeasts with ITS2-PCR followed by fragment analysis can be carried out on different capillary electrophoresis systems with comparable discriminatory power.

  11. Effects of cooking methods on electrophoretic patterns of rainbow trout

    Directory of Open Access Journals (Sweden)

    Yasemen Yanar

    2011-07-01

    Full Text Available The aim of this study was to determine the effects of different cooking methods on the electrophoretic patterns of rainbow trout (Oncorhynchus mykiss fillets using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE. Raw rainbow trout were deep-fried, microwaved, grilled, and baked and then monitored for changes in the electrophoretic pattern. All cooking methods resulted in significant moisture loss when compared to the raw sample (P

  12. Amplified fragment length polymorphism and pulsed field gel electrophoresis for subspecies differentiation of Serpulina pilosicoli

    DEFF Research Database (Denmark)

    Møller, Kristian; Jensen, Tim Kåre; Boye, Mette

    1999-01-01

    Pulsed field gel electrophoresis (PFGE) and amplified fragment length polymorphism (AFLP) were compared for their ability to differentiate between 50 porcine Serpulina pilosicoli isolates. Both techniques were highly sensitive, dividing the isolates into 36 and 38 groups, respectively. Due...

  13. Trace analysis of organic ions in ice samples by capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Huber, T. [Bern Univ. (Switzerland); Schwikowski, M.; Gaeggeler, H.W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Capillary electrophoresis was tested as a new analytical method for ice samples. Comparisons to ion chromatography were made concerning accuracy, detection limits, reproducibility, necessary sample volume and time consumption. (author) 1 fig., 3 refs.

  14. Recognition and management of common, rare, and novel serum protein electrophoresis and immunofixation interferences

    DEFF Research Database (Denmark)

    McCudden, Christopher R; Jacobs, Joannes F M; Keren, David

    2018-01-01

    Protein electrophoresis and immunofixation are subject to a variety of analytical interferences that may affect monoclonal protein diagnostics performed in the context of monoclonal gammopathies. Interferences include endogenous substances, such as hemoglobin and fibrinogen, and exogenous compounds...

  15. Modifications of alkaline microgel electrophoresis for sensitive detection of DNA damage

    International Nuclear Information System (INIS)

    Singh, N.P.; Stephens, R.E.; Schneider, E.L.

    1994-01-01

    The alkaline microgel electrophoresis technique was modified to achieve a substantial increase in sensitivity for the detection of radiation-induced DNA damage in human lymphocytes. This increased sensitivity was achieved through: (1) the addition of free radical scavengers to the electrophoresis solution to reduce DNA damage generated during alkaline unwinding and electrophoresis; (2) the modification of the electrophoresis unit to achieve a more uniform electric field; (3) the use of YOYO-1, a DNA dye, producing fluorescence 500-fold more intense than ethidium bromide; and (4) the introduction of an image analysis system for the quantitation of DNA migration. In human lymphocytes, these modifications have resulted in an increased sensitivity of several fold, allowing the detection of DNA damage in the range of 50 mGy. (author)

  16. ANALYSIS OF THE ENANTIOMERS OF CHIRAL PESTICIDES AND OTHER POLLUTANTS IN ENVIRONMENTAL SAMPLES BY CAPILLARY ELECTROPHORESIS

    Science.gov (United States)

    The generic method described here involves typical capillary electrophoresis (CE) techniques, with the addition of cyclodextrin chiral selectors to the electrolyte for enantiomer separation and also, in the case of neutral analytes, the further addition of a micelle forming comp...

  17. Electrophoresis-base dye adsorption into titanium dioxide film for dye sensitized solar cell application

    International Nuclear Information System (INIS)

    Ratno Nuryadi; Zico Alaia Akbar Junior; Lia Aprilia

    2010-01-01

    Dye Sensitized Solar Cell (DSSC) is one of renewable energy sources which has demanded a substitute non renewable energy sources. The most important factor influencing DSSC performance is dye adsorption into semiconductor nano-porous TiO 2 particles. The purpose of this work is to study the effect of dye eosin Y adsorption on DSSC characteristics by an electrophoresis method. As result, Open Circuit Voltage (V oc ) of DSSC increases as the applied voltage of electrophoresis increases. It is also found that the eosin Y absorbance at wavelength of around 500 nm increases when the electrophoresis voltage is increased. These results indicate that electrophoresis process plays an important role in dye adsorption. (author)

  18. Trace analysis of organic ions in ice samples by capillary electrophoresis

    International Nuclear Information System (INIS)

    Huber, T.; Schwikowski, M.; Gaeggeler, H.W.

    1997-01-01

    Capillary electrophoresis was tested as a new analytical method for ice samples. Comparisons to ion chromatography were made concerning accuracy, detection limits, reproducibility, necessary sample volume and time consumption. (author) 1 fig., 3 refs

  19. Applications of on-line weak affinity interactions in free solution capillary electrophoresis

    DEFF Research Database (Denmark)

    Heegaard, Niels H H; Nissen, Mogens H; Chen, David D Y

    2002-01-01

    The impressive selectivity offered by capillary electrophoresis can in some cases be further increased when ligands or additives that engage in weak affinity interactions with one or more of the separated analytes are added to the electrophoresis buffer. This on-line affinity capillary...... electrophoresis approach is feasible when the migration of complexed molecules is different from the migration of free molecules and when separation conditions are nondenaturing. In this review, we focus on applying weak interactions as tools to enhance the separation of closely related molecules, e.g., drug...... enantiomers and on using capillary electrophoresis to characterize such interactions quantitatively. We describe the equations for binding isotherms, illustrate how selectivity can be manipulated by varying the additive concentrations, and show how the methods may be used to estimate binding constants. On...

  20. Development of bufferless gel electrophoresis chip for easy preparation and rapid DNA separation.

    Science.gov (United States)

    Oleksandrov, Sergiy; Aman, Abdurazak; Lim, Wanyoung; Kim, Younghee; Bae, Nam Ho; Lee, Kyoung G; Lee, Seok Jae; Park, Sungsu

    2018-02-01

    This work presents a handy, fast, and compact bufferless gel electrophoresis chip (BGEC), which consists of precast agarose gel confined in a disposable plastic body with electrodes. It does not require large volumes of buffer to fill reservoirs, or the process of immersing the gel in the buffer. It withstands voltages up to 28.4 V/cm, thereby allowing DNA separation within 10 min with a similar separation capability to the standard gel electrophoresis. The results suggest that our BGEC is highly suitable for in situ gel electrophoresis in forensic, epidemiological settings and crime scenes where standard gel electrophoresis equipment cannot be brought in while quick results are needed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. INFLUENCE OF BORATE BUFFERS ON THE ELECTROPHORETIC BEHAVIOR OF HUMIC SUBSTANCES IN CAPILLARY ZONE ELECTROPHORESIS

    Science.gov (United States)

    The influence of tetrahydroxyborate ions on the electrophoretic mobility of humic acids was evaluated by capillary electrophoresis (CE). Depending on the molarity of borate ions in the separation buffer, the humic acids exhibit electropherograms with sharp peaks consistently exte...

  2. Ergot alkaloids as chiral selectors in capillary electrophoresis and other electromigration methods

    Czech Academy of Sciences Publication Activity Database

    Sinibaldi, M.; Messina, A.; Stodůlková, Eva; Flieger, Miroslav

    2010-01-01

    Roč. 1, č. 3 (2010), s. 233-243 ISSN 0976-5514 Institutional research plan: CEZ:AV0Z50200510 Keywords : capillary electrophoresis * capillary electrochromatography * chiral analysis Subject RIV: CB - Analytical Chemistry, Separation

  3. [The efficacy of the combined use of 5-fluorouracil electrophoresis and magnetotherapy in experimental pancreatitis].

    Science.gov (United States)

    Kents, V V; Tsympilova, T A; Mavrodiĭ, V M; Godlevskiĭ, L S

    1994-01-01

    As shown on the experimental model of rat acute pancreatitis, an intensive 5-fluorouracil electrophoresis course in combination with magnetotherapy significantly reduces the activity of blood trypsin, amylase, lipase and corticosterone. The treatment is thought effective in experimental pancreatitis.

  4. In-capillary enrichment, proteolysis and separation using capillary electrophoresis with discontinuous buffers: application on proteins with moderately acidic and basic isoelectric points.

    Science.gov (United States)

    Nesbitt, Chandra A; Yeung, Ken K-C

    2009-01-01

    Advances in mass spectrometry and capillary-format separation continue to improve the sensitivity of protein analysis. Of equal importance is the miniaturization of sample pretreatment such as enrichment and proteolysis. In a previous report (Nesbitt et al., Electrophoresis, 2008, 29, 466-474), nanoliter-volume protein enrichment, tryptic digestion, and partial separation was demonstrated in capillary electrophoresis followed by MALDI mass spectral analysis. A discontinuous buffer system, consisting of ammonium (pH 10) and acetate (pH 4), was used to create a pH junction inside the capillary, trapping a protein with a neutral isoelectric point, myoglobin (pI 7.2). Moreover, co-enrichment of myoglobin with trypsin led to an in-capillary digestion. In this paper, the ability of this discontinuous buffer system to perform similar in-capillary sample pretreatment on proteins with moderately acidic and basic pI was studied and reported. Lentil lectin (pI 8.6) and a multi-phosphorylated protein, beta-casein (pI 5.1), were selected as model proteins. In addition to the previously shown tryptic digestion, proteolysis with endoproteinase Asp-N was also performed. Digestion of these acidic and basic pI proteins produced a few peptides with extreme pI values lying outside the trapping range of the discontinuous buffer. An alteration in the peptide trapping procedure was made to accommodate these analytes. Offline MALDI mass spectral analysis confirmed the presence of the expected peptides. The presented miniaturized sample pretreatment methodology was proven to be applicable on proteins with a moderately wide range of pI. Flexibility in the choice of protease was also evident.

  5. Alkaline pH sensor molecules.

    Science.gov (United States)

    Murayama, Takashi; Maruyama, Ichiro N

    2015-11-01

    Animals can survive only within a narrow pH range. This requires continual monitoring of environmental and body-fluid pH. Although a variety of acidic pH sensor molecules have been reported, alkaline pH sensor function is not well understood. This Review describes neuronal alkaline pH sensors, grouped according to whether they monitor extracellular or intracellular alkaline pH. Extracellular sensors include the receptor-type guanylyl cyclase, the insulin receptor-related receptor, ligand-gated Cl- channels, connexin hemichannels, two-pore-domain K+ channels, and transient receptor potential (TRP) channels. Intracellular sensors include TRP channels and gap junction channels. Identification of molecular mechanisms underlying alkaline pH sensing is crucial for understanding how animals respond to environmental alkaline pH and how body-fluid pH is maintained within a narrow range. © 2015 Wiley Periodicals, Inc.

  6. Low pH Cements

    International Nuclear Information System (INIS)

    Savage, David; Benbow, Steven

    2007-05-01

    The development of low-pH cements for use in geological repositories for radioactive waste stems from concerns over the potential for deleterious effects upon the host rock and other EBS materials (notably bentonite) under the hyperalkaline conditions (pH > 12) of cement pore fluids. Low pH cement (also known as low heat cement) was developed by the cement industry for use where large masses of cement (e.g. dams) could cause problems regarding heat generated during curing. In low pH cements, the amount of cement is reduced by substitution of materials such as fly ash, blast furnace slag, silica fume, and/or non-pozzolanic silica flour. SKB and Posiva have ruled out the use of blast furnace slag and fly-ash and are focusing on silica fume as a blending agent. Currently, no preferred composition has been identified by these agencies. SKB and Posiva have defined a pH limit ≤ 11 for cement grout leachates. To attain this pH, blending agents must comprise at least 50 wt % of dry materials. Because low pH cement has little, or no free portlandite, the cement consists predominantly of calcium silicate hydrate (CSH) gel with a Ca/Si ratio ≤ 0.8. Although there are potential implications for the performance of the spent fuel and cladding due to the presence of hyperalkaline fluids from cement, the principal focus for safety assessment lies with the behaviour of bentonite. There are a number of potential constraints on the interaction of hyperalkaline cement pore fluids with bentonite, including mass balance, thermodynamic issues, mass transport, and kinetics, but none of these is likely to be limiting if conventional OPC cements are employed in repository construction. Nevertheless: Low-pH cements may supply approximately 50 % less hydroxyl ions than conventional OPC for a given volume of cement, but mass balance constraints are complicated by the uncertainty concerning the type of secondary minerals produced during cement-bentonite interaction. The change of aqueous

  7. Low pH Cements

    Energy Technology Data Exchange (ETDEWEB)

    Savage, David; Benbow, Steven [Quintessa Ltd., Henley-on-Thames (United Kingdom)

    2007-05-15

    The development of low-pH cements for use in geological repositories for radioactive waste stems from concerns over the potential for deleterious effects upon the host rock and other EBS materials (notably bentonite) under the hyperalkaline conditions (pH > 12) of cement pore fluids. Low pH cement (also known as low heat cement) was developed by the cement industry for use where large masses of cement (e.g. dams) could cause problems regarding heat generated during curing. In low pH cements, the amount of cement is reduced by substitution of materials such as fly ash, blast furnace slag, silica fume, and/or non-pozzolanic silica flour. SKB and Posiva have ruled out the use of blast furnace slag and fly-ash and are focusing on silica fume as a blending agent. Currently, no preferred composition has been identified by these agencies. SKB and Posiva have defined a pH limit {<=} 11 for cement grout leachates. To attain this pH, blending agents must comprise at least 50 wt % of dry materials. Because low pH cement has little, or no free portlandite, the cement consists predominantly of calcium silicate hydrate (CSH) gel with a Ca/Si ratio {<=} 0.8. Although there are potential implications for the performance of the spent fuel and cladding due to the presence of hyperalkaline fluids from cement, the principal focus for safety assessment lies with the behaviour of bentonite. There are a number of potential constraints on the interaction of hyperalkaline cement pore fluids with bentonite, including mass balance, thermodynamic issues, mass transport, and kinetics, but none of these is likely to be limiting if conventional OPC cements are employed in repository construction. Nevertheless: Low-pH cements may supply approximately 50 % less hydroxyl ions than conventional OPC for a given volume of cement, but mass balance constraints are complicated by the uncertainty concerning the type of secondary minerals produced during cement-bentonite interaction. The change of aqueous

  8. Role of capillary electrophoresis in the fight against doping in sports.

    Science.gov (United States)

    Harrison, Christopher R

    2013-08-06

    At present the role of capillary electrophoresis in the detection of doping agents in athletes is, for the most part, nonexistent. More traditional techniques, namely gas and liquid chromatography with mass spectrometric detection, remain the gold standard of antidoping tests. This Feature will investigate the in-roads that capillary electrophoresis has made, the limitations that the technique suffers from, and where the technique may grow into being a key tool for antidoping analysis.

  9. Recent developments and applications of capillary and microchip electrophoresis in proteomic and peptidomic analyses

    Czech Academy of Sciences Publication Activity Database

    Štěpánová, Sille; Kašička, Václav

    2016-01-01

    Roč. 39, č. 1 (2016), s. 198-211 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA13-17224S; GA ČR(CZ) GA15-01948S Institutional support: RVO:61388963 Keywords : capillary electrophoresis * mass spectrometry * microchip electrophoresis * peptidomics * proteomics Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.557, year: 2016

  10. The application of single cell gel electrophoresis or comet assay to human monitoring studies

    Directory of Open Access Journals (Sweden)

    Valverde Mahara

    1999-01-01

    Full Text Available Objective. In the search of new human genotoxic biomarkers, the single cell gel electrophoresis assay has been proposed as a sensible alternative. Material and methods. This technique detects principally single strand breaks as well as alkali-labile and repair-retarded sites. Results. Herein we present our experience using the single cell gel electrophoresis assay in human population studies, both occupationally and environmentally exposed. Conclusions. We discuss the assay feasibility as a genotoxic biomarker.

  11. VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis. Program. Summary of reports

    International Nuclear Information System (INIS)

    2001-01-01

    Program and summary of reports of the VIII All-Russian symposium on molecular liquid chromatography and capillary electrophoresis are performed. The meeting took place 15-19 October, 2001 in Moscow. Many problems of liquid and ion exchange chromatography, capillary electrophoresis, thin-layer chromatography have been discussed extensively. Reports covering properties of sorbents and devices for chromatography are incorporated in the collection [ru

  12. Detection of human DNA polymorphisms with a simplified denaturing gradient gel electrophoresis technique.

    OpenAIRE

    Noll, W W; Collins, M

    1987-01-01

    Single base pair differences between otherwise identical DNA molecules can result in altered melting behavior detectable by denaturing gradient gel electrophoresis. We have developed a simplified procedure for using denaturing gradient gel electrophoresis to detect base pair changes in genomic DNA. Genomic DNA is digested with restriction enzymes and hybridized in solution to labeled single-stranded probe DNA. The excess probe is then hybridized to complementary phage M13 template DNA, and th...

  13. Polyhedral patterns

    KAUST Repository

    Jiang, Caigui; Tang, Chengcheng; Vaxman, Amir; Wonka, Peter; Pottmann, Helmut

    2015-01-01

    We study the design and optimization of polyhedral patterns, which are patterns of planar polygonal faces on freeform surfaces. Working with polyhedral patterns is desirable in architectural geometry and industrial design. However, the classical

  14. Integrated refractive index optical ring resonator detector for capillary electrophoresis.

    Science.gov (United States)

    Zhu, Hongying; White, Ian M; Suter, Jonathan D; Zourob, Mohammed; Fan, Xudong

    2007-02-01

    We developed a novel miniaturized and multiplexed, on-capillary, refractive index (RI) detector using liquid core optical ring resonators (LCORRs) for future development of capillary electrophoresis (CE) devices. The LCORR employs a glass capillary with a diameter of approximately 100 mum and a wall thickness of a few micrometers. The circular cross section of the capillary forms a ring resonator along which the light circulates in the form of the whispering gallery modes (WGMs). The WGM has an evanescent field extending into the capillary core and responds to the RI change due to the analyte conducted in the capillary, thus permitting label-free measurement. The resonating nature of the WGM enables repetitive light-analyte interaction, significantly enhancing the LCORR sensitivity. This LCORR architecture achieves dual use of the capillary as a sensor head and a CE fluidic channel, allowing for integrated, multiplexed, and noninvasive on-capillary detection at any location along the capillary. In this work, we used electro-osmotic flow and glycerol as a model system to demonstrate the fluid transport capability of the LCORRs. In addition, we performed flow speed measurement on the LCORR to demonstrate its flow analysis capability. Finally, using the LCORR's label-free sensing mechanism, we accurately deduced the analyte concentration in real time at a given point on the capillary. A sensitivity of 20 nm/RIU (refractive index units) was observed, leading to an RI detection limit of 10-6 RIU. The LCORR marries photonic technology with microfluidics and enables rapid on-capillary sample analysis and flow profile monitoring. The investigation in this regard will open a door to novel high-throughput CE devices and lab-on-a-chip sensors in the future.

  15. The Production Rate and Employment of Ph.D. Astronomers

    Science.gov (United States)

    Metcalfe, Travis S.

    2008-02-01

    In an effort to encourage self-regulation of the astronomy job market, I examine the supply of, and demand for, astronomers over time. On the supply side, I document the production rate of Ph.D. astronomers from 1970 to 2006 using the UMI Dissertation Abstracts database, along with data from other independent sources. I compare the long-term trends in Ph.D. production with federal astronomy research funding over the same time period, and I demonstrate that additional funding is correlated with higher subsequent Ph.D. production. On the demand side, I monitor the changing patterns of employment using statistics about the number and types of jobs advertised in the AAS Job Register from 1984 to 2006. Finally, I assess the sustainability of the job market by normalizing this demand by the annual Ph.D. production. The most recent data suggest that there are now annual advertisements for about one postdoctoral job, half a faculty job, and half a research/support position for every new domestic Ph.D. recipient in astronomy and astrophysics. The average new astronomer might expect to hold up to 3 jobs before finding a steady position.

  16. Exploring chip-capillary electrophoresis-laser-induced fluorescence field-deployable platform flexibility: Separations of fluorescent dyes by chip-based non-aqueous capillary electrophoresis

    Czech Academy of Sciences Publication Activity Database

    Nuchtavorn, N.; Smejkal, Petr; Breadmore, M. C.; Guijt, R. M.; Doble, P.; Bek, F.; Foret, František; Suntornsuk, L.; Macka, M.

    2013-01-01

    Roč. 1286, APR (2013), s. 216-221 ISSN 0021-9673 R&D Projects: GA ČR(CZ) GBP206/12/G014 Institutional support: RVO:68081715 Keywords : microfluidic chip CE * capillary electrophoresis * NACE * LIF detection Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.258, year: 2013

  17. Fetal scalp pH testing

    Science.gov (United States)

    Fetal scalp blood; Scalp pH testing; Fetal blood testing - scalp; Fetal distress - fetal scalp testing; Labor - fetal scalp testing ... a baby. In these cases, testing the scalp pH can help the doctor decide whether the fetus ...

  18. Acid loading test (pH)

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003615.htm Acid loading test (pH) To use the sharing features on this page, please enable JavaScript. The acid loading test (pH) measures the ability of the ...

  19. pH sensor calibration procedure

    OpenAIRE

    Artero Delgado, Carola; Nogueras Cervera, Marc; Manuel Lázaro, Antonio; Prat Tasias, Jordi; Prat Farran, Joana d'Arc

    2013-01-01

    This paper describes the calibration of pH sensor located at the OBSEA marine Observatory. This instrument is based on an industrial pH electrode that is connected to a CTD instrument (Conductivity, Temperature, and Depth ). The calibration of the pH sensor has been done using a high precision spectrophotometer pH meter from Institute of Marine Sciences (ICM), and in this way it has been obtained a numerical function for the p H sensor propor...

  20. High-Throughput Genetic Analysis and Combinatorial Chiral Separations Based on Capillary Electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Wenwan [Iowa State Univ., Ames, IA (United States)

    2003-01-01

    Capillary electrophoresis (CE) offers many advantages over conventional analytical methods, such as speed, simplicity, high resolution, low cost, and small sample consumption, especially for the separation of enantiomers. However, chiral method developments still can be time consuming and tedious. They designed a comprehensive enantioseparation protocol employing neutral and sulfated cyclodextrins as chiral selectors for common basic, neutral, and acidic compounds with a 96-capillary array system. By using only four judiciously chosen separation buffers, successful enantioseparations were achieved for 49 out of 54 test compounds spanning a large variety of pKs and structures. Therefore, unknown compounds can be screened in this manner to identify optimal enantioselective conditions in just one rn. In addition to superior separation efficiency for small molecules, CE is also the most powerful technique for DNA separations. Using the same multiplexed capillary system with UV absorption detection, the sequence of a short DNA template can be acquired without any dye-labels. Two internal standards were utilized to adjust the migration time variations among capillaries, so that the four electropherograms for the A, T, C, G Sanger reactions can be aligned and base calling can be completed with a high level of confidence. the CE separation of DNA can be applied to study differential gene expression as well. Combined with pattern recognition techniques, small variations among electropherograms obtained by the separation of cDNA fragments produced from the total RNA samples of different human tissues can be revealed. These variations reflect the differences in total RNA expression among tissues. Thus, this Ce-based approach can serve as an alternative to the DNA array techniques in gene expression analysis.