WorldWideScience

Sample records for electronically stored blood

  1. Platelet-rich fibrin prepared from stored whole-blood samples.

    Science.gov (United States)

    Isobe, Kazushige; Suzuki, Masashi; Watanabe, Taisuke; Kitamura, Yutaka; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2017-12-01

    In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Blood samples were collected from non-smoking, healthy male donors (aged 27-67 years, N = 6), and PRF clots were prepared immediately or after storage for 1-2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Addition of optimal amounts of a 10% CaCl 2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.

  2. (G6PD) in stored blood

    African Journals Online (AJOL)

    Red blood cell viability in stored blood determines successful transfusion. Glucose-6-phosphate dehydrogenase (G6PD) activity has been shown to maintain red blood cell membrane integrity. This study was, therefore, aimed at estimating the G6PD activity in stored blood bags at the blood bank of the University of Nigeria ...

  3. Hemoglobin Function in Stored Blood.

    Science.gov (United States)

    1974-08-01

    States during 1973. Several advantages over ACA) are important. Blood stored in CPD maintains higher ./ levels of 2,3-DPG (2,3- diphosphoglycerate ) and a...survival and ATP levels in stored blood is explained by the several functions of ATP which are necessary for cell viability. However, ATP levels do...not correlate with oxygen affinity during storage. Levels of 2,3-DPG determine oxygen affinity and thus hemoglobin function. (12,13) When normal levels

  4. Autologous Transfusion of Stored Red Blood Cells Increases Pulmonary Artery Pressure

    Science.gov (United States)

    Pinciroli, Riccardo; Stowell, Christopher P.; Wang, Lin; Yu, Binglan; Fernandez, Bernadette O.; Feelisch, Martin; Mietto, Cristina; Hod, Eldad A.; Chipman, Daniel; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Zapol, Warren M.

    2014-01-01

    Rationale: Transfusion of erythrocytes stored for prolonged periods is associated with increased mortality. Erythrocytes undergo hemolysis during storage and after transfusion. Plasma hemoglobin scavenges endogenous nitric oxide leading to systemic and pulmonary vasoconstriction. Objectives: We hypothesized that transfusion of autologous blood stored for 40 days would increase the pulmonary artery pressure in volunteers with endothelial dysfunction (impaired endothelial production of nitric oxide). We also tested whether breathing nitric oxide before and during transfusion could prevent the increase of pulmonary artery pressure. Methods: Fourteen obese adults with endothelial dysfunction were enrolled in a randomized crossover study of transfusing autologous, leukoreduced blood stored for either 3 or 40 days. Volunteers were transfused with 3-day blood, 40-day blood, and 40-day blood while breathing 80 ppm nitric oxide. Measurements and Main Results: The age of volunteers was 41 ± 4 years (mean ± SEM), and their body mass index was 33.4 ± 1.3 kg/m2. Plasma hemoglobin concentrations increased after transfusion with 40-day and 40-day plus nitric oxide blood but not after transfusing 3-day blood. Mean pulmonary artery pressure, estimated by transthoracic echocardiography, increased after transfusing 40-day blood (18 ± 2 to 23 ± 2 mm Hg; P transfusing 3-day blood (17 ± 2 to 18 ± 2 mm Hg; P = 0.5). Breathing nitric oxide decreased pulmonary artery pressure in volunteers transfused with 40-day blood (17 ± 2 to 12 ± 1 mm Hg; P Transfusion of autologous leukoreduced blood stored for 40 days was associated with increased plasma hemoglobin levels and increased pulmonary artery pressure. Breathing nitric oxide prevents the increase of pulmonary artery pressure produced by transfusing stored blood. Clinical trial registered with www.clinicaltrials.gov (NCT 01529502). PMID:25162920

  5. Vitamin E nanoemulsion activity on stored red blood cells.

    Science.gov (United States)

    Silva, C A L; Azevedo Filho, C A; Pereira, G; Silva, D C N; Castro, M C A B; Almeida, A F; Lucena, S C A; Santos, B S; Barjas-Castro, M L; Fontes, A

    2017-06-01

    Stored red blood cells (RBCs) undergo numerous changes that have been termed RBC storage lesion, which can be related to oxidative damage. Vitamin E is an important antioxidant, acting on cell lipids. Thus, this study aimed to investigate vitamin E activity on stored RBCs. We prepared a vitamin E nanoemulsion that was added to RBC units and stored at 4 °C. Controls, without vitamin E, were kept under the same conditions. Reactive oxygen species (ROS) production was monitored for up to 35 days of storage. RBC elasticity was also evaluated using an optical tweezer system. Vitamin E-treated samples presented a significant decrease in ROS production. Additionally, the elastic constant for vitamin E-treated RBCs did not differ from the control. Vitamin E decreased the amount of ROS in stored RBCs. Because vitamin E acts on lipid oxidation, results suggest that protein oxidation should also be considered a key factor for erythrocyte elastic properties. Thus, further studies combining vitamin E with protein antioxidants deserve attention, aiming to better preserve overall stored RBC properties. © 2017 British Blood Transfusion Society.

  6. Stability of carboxyhemoglobin in stored and mailed blood samples.

    Science.gov (United States)

    Hampson, Neil B

    2008-02-01

    Elevated blood carboxyhemoglobin (COHb) levels are used to confirm a clinical diagnosis of exposure to carbon monoxide (CO) and, in some instances, assess severity of poisoning. However, many hospital laboratories cannot measure COHb because they do not have CO-oximeters. In such instances, blood samples are often sent to outside laboratories or with a transported patient for measurement at the receiving hospital. This study was conducted to assess the stability of COHb in stored and mailed blood samples anticoagulated with heparin. Adult human blood was drawn into standard sample tubes anticoagulated with sodium heparin. Carbon monoxide gas was infused to raise the COHb level to 25% to 35%. Samples were then refrigerated or stored at room temperature, and serial COHb determinations were performed for 28 days. Additional samples were measured after being mailed locally or across the United States and back. No significant changes in COHb levels were seen in samples stored either in refrigeration or at room temperature over a period of 28 days or in samples shipped without refrigeration locally or across the United States. Carboxyhemoglobin levels in whole blood samples anticoagulated with heparin are stable with or without refrigeration for up to 4 weeks. If COHb measurement capability is not available, such samples may be shipped or transported with patients with confidence that the COHb level will be stable when measured at a later time.

  7. Modelling impulsive factors for electronics and restaurant coupons’ e-store display

    Science.gov (United States)

    Ariningsih, P. K.; Nainggolan, M.; Sandy, I. A.

    2018-04-01

    In many times, the increment of e-store visitors does not followed by sales increment. Most purchases through e-commerce are impulsive buying, however only small amount of study is available to understand impulsive factors of e-store display. This paper suggests a preliminary concept on understanding the impulsive factors in Electronics and Restaurant Coupons e-store display, which are two among few popular group products sold through e-commerce. By conducting literature study and survey, 31 attributes were identified as impulsive factors in electronics e-store display and 20 attributes were identified as impulsive factors for restaurant coupon e-store. The attributes were then grouped into comprehensive impulsive factors by factor analysis. Each group of impulsive attributes were generated into 3 factors. Accessibility Factors and Trust Factors appeared for each group products. The other factors are Internal Factors for electronics e-store and Marketing factors for restaurant coupons e-store. Structural Equation Model of the impulsive factors was developed for each type of e-store, which stated the covariance between Trust Factors and Accessibility Factors. Based on preliminary model, Internal Factor and Trust Factor are influencing impulsive buying in electronics store. Special factor for electronics e-store is Internal Factor, while for restaurant coupons e-store is Marketing Factor.

  8. Reduction of bioactive substances in stored donor blood: prestorage versus bedside leucofiltration

    DEFF Research Database (Denmark)

    Hammer, J H; Mynster, T; Reimert, C M

    1999-01-01

    Leucocyte filtration has been suggested to improve transfusion products. We studied the effect of prestorage versus bedside leucofiltration on reduction of bioactive substances and leucocyte content in donor blood. Forty-five units of whole blood from healthy blood donors were studied....... Of these units, 9 were stored under standard conditions for 35 d, 9 were leucofiltered after donation and then stored for 35 d, and 3x9 units were stored for 7, 21 and 35 d, respectively, before leucofiltration. Samples were collected from blood units immediately after donation, and before and after...... leucofiltration, and analysed by ELISA and RIA methods for extracellular content of myeloperoxidase (MPO), eosinophil cationic protein (ECP), histamine (HIS) and plasminogen activator inhibitor-1 (PAI-1). Leucocyte content was counted in all samples. In non-filtered blood extracellular MPO, ECP, HIS and PAI-1...

  9. Analysis of RBC-microparticles in stored whole blood bags - a promising marker to detect blood doping in sports?

    Science.gov (United States)

    Voss, Sven Christian; Jaganjac, Morana; Al-Thani, Amna Mohamed; Grivel, Jean-Charles; Raynaud, Christophe Michel; Al-Jaber, Hind; Al-Menhali, Afnan Saleh; Merenkov, Zeyed Ahmad; Alsayrafi, Mohammed; Latiff, Aishah; Georgakopoulos, Costas

    2017-11-01

    Blood doping in sports is prohibited by the World Anti-Doping Agency (WADA). To find a possible biomarker for the detection of blood doping, we investigated the changes in blood stored in CPDA-1 blood bags of eight healthy subjects who donated one unit of blood. Aliquots were taken on days 0, 14, and 35. Platelet-free plasma was prepared and stored at -80°C until analysis on a flow cytometer dedicated for the analysis of microparticles (MPs). Changes in the number of red blood cell (RBC) -MPs were highly significant (p doping control but confirmation by a transfusion study is necessary. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Time Dependent Assessment of Morphological Changes: Leukodepleted Packed Red Blood Cells Stored in SAGM

    Directory of Open Access Journals (Sweden)

    Ibrahim Mustafa

    2016-01-01

    Full Text Available Usually packed red blood cells (pRBCs require specific conditions in storage procedures to ensure the maximum shelf life of up to 42 days in 2–6°C. However, molecular and biochemical consequences can affect the stored blood cells; these changes are collectively labeled as storage lesions. In this study, the effect of prolonged storage was assessed through investigating morphological changes and evaluating oxidative stress. Samples from leukodepleted pRBC in SAGM stored at 4°C for 42 days were withdrawn aseptically on day 0, day 14, day 28, and day 42. Morphological changes were observed using scanning electron microscopy and correlated with osmotic fragility and hematocrit. Oxidative injury was studied through assessing MDA level as a marker for lipid peroxidation. Osmotic fragility test showed that extended storage time caused increase in the osmotic fragility. The hematocrit increased by 6.6% from day 0 to day 42. The last 2 weeks show alteration in the morphology with the appearance of echinocytes and spherocytes. Storage lesions and morphological alterations appeared to affect RBCs during the storage period. Further studies should be performed to develop strategies that will aid in the improvement of stored pRBC quality and efficacy.

  11. Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags.

    Science.gov (United States)

    Buckley, K; Atkins, C G; Chen, D; Schulze, H G; Devine, D V; Blades, M W; Turner, R F B

    2016-03-07

    After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 °C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.

  12. Time-dependent histamine release from stored human blood products

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørgen; Edvardsen, L; Vangsgaard, K

    1996-01-01

    storage. Whole blood (six units), plasma-reduced whole blood (six units), and plasma- and buffy coat-reduced (saline-adenine-glucose-mannitol) (SAGM) blood (six units) from unpaid healthy donors were stored in the blood bank for 35 days at 4 degrees C. Plasma histamine and total cell-bound histamine......Perioperative transfusion of whole blood has been shown to amplify trauma-induced immunosuppression, which could be attenuated by perioperative administration of histamine2 receptor antagonists. Supernatants from different blood products were, therefore, analysed for histamine content during.......0 (range 176.0-910.0) nmol/l in whole blood and 475.0 (range 360.0-1560.0) nmol/l in plasma-reduced whole blood, while it was undetectable in SAGM blood. Spontaneous histamine release increased in a time-dependent manner from a median of 6.7 (range 2.2-17.4) nmol/l at the time of storage to 175.0 (range 33...

  13. 2,3-Diphosphoglycerate Concentrations in Autologous Salvaged Versus Stored Red Blood Cells and in Surgical Patients After Transfusion.

    Science.gov (United States)

    Scott, Andrew V; Nagababu, Enika; Johnson, Daniel J; Kebaish, Khaled M; Lipsitz, Joshua A; Dwyer, Ian M; Zuckerberg, Gabriel S; Barodka, Viachaslau M; Berkowitz, Dan E; Frank, Steven M

    2016-03-01

    Stored red blood cells (RBCs) are deficient in 2,3-diphosphoglycerate (2,3-DPG), but it is unclear how autologous salvaged blood (ASB) compares with stored blood and how rapidly 2,3-DPG levels return to normal after transfusion. Therefore, we compared levels of 2,3-DPG in stored versus ASB RBCs and in patients' blood after transfusion. Twenty-four patients undergoing multilevel spine fusion surgery were enrolled. We measured 2,3-DPG and the oxyhemoglobin dissociation curve (P50) in samples taken from the ASB and stored blood bags before transfusion and in blood samples drawn from patients before and after transfusion. The mean storage duration for stored RBCs was 24 ± 8 days. Compared with fresh RBCs, stored RBCs had decreased 2,3-DPG levels (by approximately 90%; P levels recovered gradually over 3 postoperative days in patients who received stored RBCs. Stored RBCs, but not ASB RBCs, have decreased levels of 2,3-DPG and a left-shift in the oxyhemoglobin dissociation curve. Postoperatively, 2,3-DPG levels remain below preoperative baseline levels for up to 3 postoperative days in patients who receive stored RBCs but are unchanged in those who receive only ASB RBCs.

  14. Comparison of Stored Umbilical Cord Blood and Adult Donor Blood: Transfusion Feasibility

    Directory of Open Access Journals (Sweden)

    Rola Sahyoun-tokan

    2012-09-01

    Full Text Available OBJECTIVE: This study aimed to compare the storage properties of red blood cell (RBC concentrates of umbilical cord blood (UCB and adult donor blood (ADB, and to evaluate the feasibility of UCB-RBC concentrate as an autologous source for blood transfusion in very low birth weight (VLBW preterm neonates. METHODS: In all, 30 newborn (10 preterm, 20 full term UCB and 31 ADB units were collected. RBC concentrates were stored and compared with regard to pH, potassium (K+, 2,3-biphosphoglycerate (2-3-BPG, adenosine tri-phosphate (ATP, plasma Hb, and bacterial contamination on d 1, 21, and 35 of storage. RESULTS: The K+ level increased with time and differed significantly between storage d 1 and 21, and between storage d 1 and 35 in both the UCB and ADB units. Initial and d 21 K+ levels were higher in the UCB units than in the ADB units. The 2,3-BPG level did not differ significantly between the UCB-PRC and ADB-PRC samples. After 35 d of storage both UCB-PRC and ADB-PRC samples exhibited significant differences from the initial free Hb, intracellular ATP, and pH values. Significant differences in intracellular ATP and pH were also observed between the UCB-PRC and ADB-PRC samples. CONCLUSION: The volume of harvested and prepared UCB-PRC can be used for some of the blood transfusions required during the neonatal period and thus may decrease the number of allogeneic transfusions, especially in preterm newborns. The hematological and biochemical changes that occurred in UCB during storage were comparable with those observed in ADB, and do not pose a risk to the immature metabolism of neonates. UCB-RPC prepared and stored under standard conditions can be a safe alternative RBC source for transfusions in VLBW newborns.

  15. Comparison of stored umbilical cord blood and adult donor blood: transfusion feasibility.

    Science.gov (United States)

    Tokan, Rola Sahyoun; Arsan, Saadet; Erdeve, Omer; Solaz, Nuri; Avcı, Aslıhan; Ulkar, Serenay Elgün; Gülyapar, Elif; Ustünyurt, Zeynep; Bıyıklı, Zeynep; Kemahlı, Sabri

    2012-09-01

    This study aimed to compare the storage properties of red blood cell (RBC) concentrates of umbilical cordblood (UCB) and adult donor blood (ADB), and to evaluate the feasibility of UCB-RBC concentrate as an autologoussource for blood transfusion in very low birth weight (VLBW) preterm neonates. In all, 30 newborn (10 preterm, 20 full term) UCB and 31 ADB units were collected.RBC concentrates were stored and compared with regard to pH, potassium (K(+)), 2,3-biphosphoglycerate (2-3-BPG),adenosine tri-phosphate (ATP), plasma Hb, and bacterial contamination on d 1, 21, and 35 of storage. The K(+) level increased with time and differed significantly between storage d 1 and 21, and between storaged 1 and 35 in both the UCB and ADB units. Initial and d 21 K(+) levels were higher in the UCB units than in the ADBunits. The 2,3-BPG level did not differ significantly between the UCB-PRC and ADB-PRC samples. After 35 d of storageboth UCB-PRC and ADB-PRC samples exhibited significant differences from the initial free Hb, intracellular ATP, andpH values. Significant differences in intracellular ATP and pH were also observed between the UCB-PRC and ADB-PRCsamples. The volume of harvested and prepared UCB-PRC can be used for some of the blood transfusions requiredduring the neonatal period and thus may decrease the number of allogeneic transfusions, especially in preterm newborns.The hematological and biochemical changes that occurred in UCB during storage were comparable with those observedin ADB, and do not pose a risk to the immature metabolism of neonates. UCB-RPC prepared and stored under standardconditions can be a safe alternative RBC source for transfusions in VLBW newborns.

  16. Platelet function in stored heparinised autologous blood is not superior to in patient platelet function during routine cardiopulmonary bypass.

    Directory of Open Access Journals (Sweden)

    Rolf C G Gallandat Huet

    Full Text Available BACKGROUND: In cardiac surgery, cardiopulmonary bypass (CPB and unfractionated heparin have negative effects on blood platelet function. In acute normovolemic haemodilution autologous unfractionated heparinised blood is stored ex-vivo and retransfused at the end of the procedure to reduce (allogeneic transfusion requirements. In this observational study we assessed whether platelet function is better preserved in ex vivo stored autologous blood compared to platelet function in the patient during CPB. METHODOLOGY/PRINCIPAL FINDING: We measured platelet aggregation responses pre-CPB, 5 min after the start of CPB, at the end of CPB, and after unfractionated heparin reversal, using multiple electrode aggregometry (Multiplate® with adenosine diphosphate (ADP, thrombin receptor activating peptide (TRAP and ristocetin activated test cells. We compared blood samples taken from the patient with samples taken from 100 ml ex-vivo stored blood, which we took to mimick blood storage during normovolemic haemodilution. Platelet function declined both in ex-vivo stored blood as well as in blood taken from the patient. At the end of CPB there were no differences in platelet aggregation responses between samples from the ex vivo stored blood and the patient. CONCLUSION/SIGNIFICANCE: Ex vivo preservation of autologous blood in unfractionated heparin does not seem to be profitable to preserve platelet function.

  17. Mechanical properties of stored red blood cells using optical tweezers

    Science.gov (United States)

    Fontes, Adriana; Alexandre de Thomaz, Andre; de Ysasa Pozzo, Liliana; de Lourdes Barjas-Castro, Maria; Brandao, Marcelo M.; Saad, Sara T. O.; Barbosa, Luiz Carlos; Cesar, Carlos Lenz

    2005-08-01

    We have developed a method for measuring the red blood cell (RBC) membrane overall elasticity μ by measuring the deformation of the cells when dragged at a constant velocity through a plasma fluid by an optical tweezers. The deformability of erythrocytes is a critical determinant of blood flow in the microcirculation. We tested our method and hydrodynamic models, which included the presence of two walls, by measuring the RBC deformation as a function of drag velocity and of the distance to the walls. The capability and sensitivity of this method can be evaluated by its application to a variety of studies, such as, the measurement of RBC elasticity of sickle cell anemia patients comparing homozygous (HbSS), including patients taking hydroxyrea (HU) and heterozygous (HbAS) with normal donors and the RBC elasticity measurement of gamma irradiated stored blood for transfusion to immunosupressed patients as a function of time and dose. These studies show that the technique has the sensitivity to discriminate heterozygous and homozygous sickle cell anemia patients from normal donors and even follow the course of HU treatment of Homozygous patients. The gamma irradiation studies show that there is no significant change in RBC elasticity over time for up to 14 days of storage, regardless of whether the unit was irradiated or not, but there was a huge change in the measured elasticity for the RBC units stored for more than 21 days after irradiation. These finds are important for the assessment of stored irradiated RBC viability for transfusion purposes because the present protocol consider 28 storage days after irradiation as the limit for the RBC usage.

  18. Whole blood samples for adrenocorticotrophic hormone measurement can be stored at room temperature for 4 hours

    DEFF Research Database (Denmark)

    Christensen, Mette; Madsen, Rikke Fogt; Møller, Line Rosengreen

    2016-01-01

    INTRODUCTION: The aim of this study was to investigate and compare the stability of adrenocorticotrophic hormone (ACTH) in whole blood stored on ice and at room temperature for up to 48 hours. This study differs from previous studies by a larger data material. MATERIALS AND METHODS: EDTA-blood sa......INTRODUCTION: The aim of this study was to investigate and compare the stability of adrenocorticotrophic hormone (ACTH) in whole blood stored on ice and at room temperature for up to 48 hours. This study differs from previous studies by a larger data material. MATERIALS AND METHODS: EDTA......-blood samples from 30 patients were collected, aliquoted and stored on ice or at room temperature for 0, 2, 4, 24, or 48 h before centrifugation, and the plasma was stored frozen until analysis. All samples were analyzed using an automated electrochemiluminescence immunoassay on cobas 6000 e601. The change...

  19. Iron stores in regular blood donors in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Adediran A

    2013-06-01

    Full Text Available Adewumi Adediran,1 Ebele I Uche,2 Titilope A Adeyemo,1 Dapus O Damulak,3 Akinsegun A Akinbami,4 Alani S Akanmu1 1Department of Hematology and Blood Transfusion, University of Lagos, Lagos, Nigeria; 2Department of Hematology and Blood Transfusion, Lagos University Teaching Hospital, Lagos, Nigeria; 3Department of Hematology and Blood Transfusion, Jos University Teaching Hospital, Jos, Nigeria; 4Department of Hematology and Blood Transfusion, Lagos State University, Ikeja, Nigeria Background: Apart from challenging the bone marrow to increase its red cell production, thereby producing more blood for the donor, regular blood donation has been shown to have several benefits, one of which is preventing accumulation of body iron which can cause free radical formation in the body. This study was carried out to assess body iron stores in regular blood donors. Methods: A total of 52 regular (study and 30 first-time (control volunteer blood donors were studied prospectively. Twenty milliliters of venous blood was drawn from each subject, 5 mL of which was put into sodium ethylenediamine tetra-acetic acid specimen bottles for a full blood count, including red blood cell indices. The remaining sample was allowed to clot in a plain container, and the serum was then retrieved for serum ferritin, serum iron, and serum transferrin receptor measurement by enzyme-linked immunosorbent assay. Results: Mean hemoglobin and packed cell volume in the study group (13.47 ± 2.36 g/dL and 42.00 ± 7.10, respectively, P = 0.303 were not significantly higher than in the control group (12.98 ± 1.30 g/dL and 39.76 ± 4.41, respectively, P = 0.119. Mean serum ferritin was 102.46 ± 80.26 ng/mL in the control group and 41.46 ± 40.33 ng/mL in the study group (P = 0.001. Mean serum ferritin for women in the study group (28.02 ± 25.00 ng/mL was significantly lower than for women in the control group (56.35 ± 34.03 ng/mL, P = 0.014. Similarly, men in the study group had a lower

  20. Evaluation of hematologic, blood gas, and select biochemical variables in ovine whole blood stored in CPDA-1 bags.

    Science.gov (United States)

    Sousa, Rejane S; Barrêto, Raimundo A; Sousa, Isadora K F; Chaves, Dowglish F; Soares, Herbert S; Barros, Isabella O; Minervino, Antonio H H; Ortolani, Enrico L

    2013-03-01

    The economic consequences from mortality of sheep after blood loss can be considerable. To date there are no reports addressing hematologic, blood gas, and biochemical changes in ovine blood stored in CPDA-1 bags. The aim of this study was to investigate hematologic, blood gas, and biochemical alterations resulting from storage of ovine blood in CPDA-1 bags to establish transfusion protocols in sheep. From each of 7 healthy 8-month-old sheep 450 mL of blood were collected into CPDA-1 bags and stored for 35 days in at 3-6°C. Samples were taken from the bags at days 0, 7, 14, 21, and 35. Whole blood was used to assess PCV, MCV, RBC count, pH, pO2 , pCO2 , and concentrations of bicarbonate, sodium, and lactate. Plasma was used to measure potassium, hemoglobin, and glucose concentrations. The PCV remained stable throughout the storage period, while plasma hemoglobin and MCV began to increase on days 7 and 21, respectively. The RBC count began to decrease on day 21. Blood pH decreased and pCO2 increased steadily throughout the storage period. Potassium concentration increased from 3.8 to 18.3 mmol/L on day 7 and remained high thereafter. In contrast, sodium concentration began to decrease on day 7. The results show that ovine blood undergoes hematologic, blood gas, and biochemical changes during storage. Further studies are required to establish RBC viability in CPDA-1 bags after a storage period of 35 days. © 2012 American Society for Veterinary Clinical Pathology.

  1. Inhibition of Platelet Aggregation by Supernates from Stored Red Blood Cells

    Science.gov (United States)

    2010-04-01

    450 μl of blood or 450 μl of platelet rich plasma (PRP) was mixed with 225 μl of supernate plus 225 μl of Tyrode’s buffer and incubated for ten... platelet counts, prothrombin time, activated partial thromboplastin time, fibrinogen, fibrin split products, and FVIII:Rag also measured 30 minutes...RTO-MP-HFM-182 22 - 1 Inhibition of Platelet Aggregation by Supernates from Stored Red Blood Cells Dr. Steve J. McFaul, LT Frederick A

  2. Biomarker Analysis of Stored Blood Products: Emphasis on Pre-Analytical Issues

    Science.gov (United States)

    Delobel, Julien; Rubin, Olivier; Prudent, Michel; Crettaz, David; Tissot, Jean-Daniel; Lion, Niels

    2010-01-01

    Millions of blood products are transfused every year; many lives are thus directly concerned by transfusion. The three main labile blood products used in transfusion are erythrocyte concentrates, platelet concentrates and fresh frozen plasma. Each of these products has to be stored according to its particular components. However, during storage, modifications or degradation of those components may occur, and are known as storage lesions. Thus, biomarker discovery of in vivo blood aging as well as in vitro labile blood products storage lesions is of high interest for the transfusion medicine community. Pre-analytical issues are of major importance in analyzing the various blood products during storage conditions as well as according to various protocols that are currently used in blood banks for their preparations. This paper will review key elements that have to be taken into account in the context of proteomic-based biomarker discovery applied to blood banking. PMID:21151459

  3. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  4. Digital stacks, how to store and manage your electronic digital stacks

    NARCIS (Netherlands)

    Boheemen, van P.J.C.

    2009-01-01

    Libraries have always been known for their skills in describing, archiving and storing books and journals. Now we see that libraries have to deal with local copies of electronic publications. Describing them the way they have described paper publications can be done in the same way. Storing them on

  5. 76 FR 51041 - Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop

    Science.gov (United States)

    2011-08-17

    ...] Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop AGENCY: Food and... Donors.'' The purpose of this public workshop is to discuss blood donor hemoglobin and hematocrit qualification standards in the United States, its impact on donor safety and blood availability, and potential...

  6. Evaluation of Glucose-6-Phosphate Dehydrogenase stability in stored blood samples.

    Science.gov (United States)

    Jalil, Norunaluwar; Azma, Raja Zahratul; Mohamed, Emida; Ithnin, Azlin; Alauddin, Hafiza; Baya, Siti Noor; Othman, Ainoon

    2016-01-01

    Glucose-6-Phosphate Dehydrogenase (G6PD) deficiency is the commonest cause of neonatal jaundice in Malaysia. Recently, OSMMR2000-D G6PD Assay Kit has been introduced to quantitate the level of G6PD activity in newborns delivered in Universiti Kebangsaan Malaysia Medical Centre (UKMMC). As duration of sample storage prior to analysis is one of the matters of concern, this study was conducted to identify the stability of G6PD enzyme during storage. A total of 188 cord blood samples from normal term newborns delivered at UKMMC were selected for this study. The cord bloods samples were collected in ethylene-diamine-tetra-acetic acid (EDTA) tubes and refrigerated at 2-8 °C. In addition, 32 out of 188 cord blood samples were spotted on chromatography paper, air-dried and stored at room temperature. G6PD enzyme activities were measured daily for 7 days using the OSMMR2000-D G6PD Assay Kit on both the EDTA blood and dried blood samples. The mean value for G6PD activity was compared between days of analysis using Student Paired T-Test. In this study, 172 out of 188 cord blood samples showed normal enzyme levels while 16 had levels corresponding to severe enzyme deficiency. The daily mean G6PD activity for EDTA blood samples of newborns with normal G6PD activity showed a significant drop on the fourth day of storage (p samples with severely deficient G6PD activity, significant drop was seen on third day of storage (p = 0.002). Analysis of dried cord blood showed a significant reduction in enzyme activity as early as the second day of storage (p = 0.001). It was also noted that mean G6PD activity for spotted blood samples were lower compared to those in EDTA tubes for all days (p = 0.001). Thus, EDTA blood samples stored at 2-8 °C appeared to have better stability in terms of their G6PD enzyme level as compared to dried blood samples on filter paper, giving a storage time of up to 3 days.

  7. The Heritability of Glutathione and Related Metabolites in Stored Red Blood Cells

    OpenAIRE

    van ‘t Erve, Thomas J.; Doskey, Claire M.; Wagner, Brett A.; Hess, John R.; Darbro, Benjamin W.; Ryckman, Kelli K.; Murray, Jeffrey C.; Raife, Thomas J.; Buettner, Garry R.

    2014-01-01

    Red blood cells (RBCs) collected for transfusion deteriorate during storage. This deterioration is termed the “RBC storage lesion”. There is increasing concern over the safety, therapeutic efficacy, and toxicity of transfusing longer-stored units of blood. The severity of the RBC storage lesion is dependent on storage-time and varies markedly between individuals. Oxidative damage is considered a significant factor in development of the RBC storage lesion. In this study, the variability during...

  8. Stability and reliability of glycated haemoglobin measurements in blood samples stored at -20°C.

    Science.gov (United States)

    Venkataraman, Vijayachandrika; Anjana, Ranjit Mohan; Pradeepa, Rajendra; Deepa, Mohan; Jayashri, Ramamoorthy; Anbalagan, Viknesh Prabu; Akila, Bridgitte; Madhu, Sri Venkata; Lakshmy, Ramakrishnan; Mohan, Viswanathan

    2016-01-01

    To validate the stability of glycated haemoglobin (HbA1c) measurements in blood samples stored at -20°C for up to one month. The study group comprised 142 type 2 diabetic subjects visiting a tertiary centre for diabetes at Chennai city in south India. The HbA1c assay was done on a fasting blood sample using the Bio-Rad Variant machine on Day 0 (day of blood sample collection). Several aliquots were stored at -20°C and the assay was repeated on the 3rd, 7th, 15th, and 30th day after the sample collection. Bland-Altman plots were constructed and variation in the HbA1c levels on the different days was compared with the day 0 level. The median differences between HbA1c levels measured on Day 0 and the 3rd, 7th, 15th, and 30th day after blood collection were 0.0%, 0.2%, 0.3% and 0.5% respectively. Bland-Altman plot analysis showed that the differences between the day '0' and the different time points tend to get larger with time, but these were not clinically significant. HbA1c levels are relatively stable up to 2weeks, if blood samples are stored at -20°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. The Relationship of Oxidation Sensitivity of Red Blood Cells and Carbonic Anhydrase Activity in Stored Human Blood: Effect of Certain Phenolic Compounds

    Directory of Open Access Journals (Sweden)

    Zübeyir Huyut

    2016-01-01

    Full Text Available It has been reported that many modifications occur with the increase of oxidative stress during storage in erythrocytes. In order to delay these negative changes, we evaluated whether the addition of substances likely to protect antioxidant capacity in stored blood would be useful. Therefore, we investigated the effects of resveratrol, tannic acid, and caffeic acid in lipid peroxidation and antioxidant capacity of erythrocytes in stored blood. Donated blood was taken into four CPD containing blood bags. One bag was used as the control, and the others were supplemented with caffeic acid (30 μg/mL, resveratrol (30 μg/mL, and tannic acid (15 μg/mL, respectively. Erythrocyte lipid peroxidation, sensitivity to oxidation, glutathione levels and carbonic anhydrase, glutathione peroxidase, and catalase activities were measured on days 0, 7, 14, 21, and 28. In the control group, erythrocyte malondialdehyde levels and sensitivity to oxidation were increased whereas glutathione, glutathione peroxidase, and catalase levels were decreased (p<0.05. Resveratrol and caffeic acid prevented malondialdehyde accumulation and preserved glutathione, glutathione peroxidase, and catalase activities in erythrocytes. We demonstrated that resveratrol, caffeic acid, and tannic acid in stored blood could decrease the sensitivity to oxidation of erythrocytes in vitro but did not exhibit such effects on CA activity.

  10. Electron, photons, and molecules: Storing energy from light

    Energy Technology Data Exchange (ETDEWEB)

    Miller, J.R. [Argonne National Laboratory, IL (United States)

    1996-09-01

    Molecular charge separation has important potential for photochemical energy storage. Its efficiency can be enhanced by principals which maximize the rates of the electron transfer steps which separate charge and minimize those which recombine high-energy charge pairs to lose stored energy. Dramatic scientific progress in understanding these principals has occurred since the founding of DOE and its predecessor agency ERDA. While additional knowledge in needed in broad areas of molecular electron transfer, some key areas of knowledge hold particular promise for the possibility of moving this area from science toward technology capable of contributing to the nation`s energy economy.

  11. The efficacy of erythrocytes isolated from blood stored under blood bank conditions.

    Science.gov (United States)

    Rajashekharaiah, Vani; Koshy, Abel Abraham; Koushik, Amit Kumar; Kaur, Harsimran; Kumari, Kavita; Agrawal, Madhusudan; Priyanka; Ramya; Khatai, Smrutishree; Gowda, Vaishnavi; Kumar, Vinay

    2012-12-01

    The RBCs storage lesion is most carefully viewed as the sum of all the changes in RBCs occurring during the course of storage and that limit their survival. Erythrocytes were isolated from stored blood at regular intervals. Oxidative stress markers were analyzed to determine the changes during the storage. Antioxidant enzymes--(SOD and CAT), and SH showed insignificant variation whereas hemolysis, MDA and AOPP showed significant variations. The oxidative stress has not successfully overridden the protection offered by the endogenous antioxidant system. Prolonged storage may result in the onset of erythrocyte deterioration. This clearly indicates that the erythrocytes are capable of attenuating ROS with 2 weeks of storage. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Platelets in blood stored in untreated and siliconed glass bottles and plastic bags

    Science.gov (United States)

    Kissmeyer-Nielsen, F.; Madsen, C. B.; Nedergaard, Jytte

    1961-01-01

    Platelet survival was determined using untreated and siliconed glass bottles and plastic bags (Fenwal) for collecting and storing blood. The platelets were tagged in vivo with P32 in six polycythaemic patients undergoing treatment with P32. The results showed that fresh ACD blood collected in untreated glass, siliconed glass, and plastic gave the same recovery of platelets in the recipients. The use of EDTA (Fenwal formula) as anticoagulant gave results inferior to those obtained with blood using ACD as anticoagulant. Even after storage up to 24 hours in untreated glass bottles (ordinary bank blood) a satisfactory recovery of platelets was observed. After storage for 72 hours the recovery was less but not negligible. PMID:14456481

  13. Unusual spontaneous cold auto-hemagglutination phenomenon in blood units stored under blood bank condition: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Sanmukh R Joshi

    2015-01-01

    Full Text Available Background: Cold agglutinins (CA are benign naturally occurring low titer autoantibodies present in most individuals. Those with moderate strength are found in infections, malignancies or autoimmune conditions with diagnostic importance. Aim: Present report deals with CA that brought spontaneous hemagglutination in blood units stored at 2-6°C. Study design: Over 32 months period between July 1993 and December 1995, blood units were inspected for spontaneous cold auto-hemagglutination (SpCA phenomenon. The plasma from these units was separated and investigated for serological specificity using in house red cell panel and standard serological methods. Results: Among 51,671 blood units, 112 units showed SpCA phenomenon. A rising trend seen in first half of study period significantly fell in remaining half. Specificities of the antibodies detected include anti-I (27, anti-i (53, anti-Pr (21 with remaining few being undetermined specificity. Absorption of serum using enzyme-treated red cells revealed a presence of anti-Pr among the cases, the two of which with new specificities that reacted preferentially with red cells from either new-born or adults and were tentatively named as anti-Pr Fetal and anti-Pr adult , respectively. While 9 cases showed optimum reaction at neutral pH of 7, 68 (62% cases reacted at pH 5.8 through 8.0, 28 (26% cases preferred an acidic pH 5.8 and 4 cases opted an alkaline pH 8. Of 28 cases with antibodies preferentially reacting in acidic medium, 17 (60% cases were anti-i and 7 (25% cases were anti-Pr. Conclusion: Unique SpCA phenomenon observed in blood units stored under blood bank conditions seems to be due to CA developed in response to vector-borne infectious agents. Majority of the cases displayed their specificities, otherwise are rare to be encountered.

  14. Stability of benzodiazepines and cocaine in blood spots stored on filter paper.

    Science.gov (United States)

    Alfazil, Abdulkareem A; Anderson, Robert A

    2008-09-01

    Previous studies have shown that drug concentrations in blood can change during storage, especially at room temperature, but even labile drugs such as cocaine may be stable in dried blood spots (DBS). A new method has been developed for the analysis of hydrolytically labile drugs in blood spots on filter paper in order to assess their degradation during a storage period of one month. The drugs selected included flunitrazepam, temazepam, oxazepam, lorazepam, nitrazepam, diazepam, and cocaine. A Guthrie card 903 was spotted with 100 microL of blood containing the drugs at concentrations of 1000 ng/mL and left overnight to dry at room temperature. The filter paper was suspended in extraction buffer for 1 h with ultrasonication. Drugs were then extracted from the buffer by solid-phase extraction using Clean Screen((R)) columns and analyzed by liquid chromatography-tandem mass spectrometry. Method validation showed that all calibration curves were linear over the concentration range 5-200 ng/spot with correlation coefficients of 0.994-0.999. Interday and intraday precisions at three concentrations (10, 50, and 100 ng/spot) were 1.6-18.3% and 2.8-14.7%, respectively. Limits of detection were 0.29-0.74 ng/spot, and lower limits of quantitation were 0.99-2.46 ng/spot. Recoveries of all analytes were in the range 81-106%. DBS were stored in duplicate at room temperature, 4 degrees C, and -20 degrees C for up to one month. Degradation of the drugs in DBS at all storage conditions was less than for the corresponding liquid blood samples stored under similar conditions and more than 80% of each analyte could be recovered from the samples.

  15. Stores

    CERN Multimedia

    2004-01-01

    Following the introduction of Condensators, resistors and potentiometers from the Farnell electronic-catalogue into CERN Stores' catalogue, following products are now available: PRODUCT FAMILY GROUP SCEM Oscillators and quartz crystals 07.94.10 / 07.94.12 Diodes 08.51.14 / 08.51.54 Thyristors 08.51.60 / 08.51.66 Opto-electronics 08.52 Transistors 08.53 Integrated circuits 08.54 / 08.55 These articles can be procured in the same way as any other stores item, by completing a Material Request. N.B. Individual Farnell order codes can be used as keywords to facilitate searches in the CERN Stores Catalogue.

  16. Non-perturbative calculation of equilibrium polarization of stored electron beams

    International Nuclear Information System (INIS)

    Yokoya, Kaoru.

    1992-05-01

    Stored electron/positron beams polarize spontaneously owing to the spin-flip synchrotron radiation. In the existing computer codes, the degree of the equilibrium polarization has been calculated using perturbation expansions in terms of the orbital oscillation amplitudes. In this paper a new numerical method is presented which does not employ the perturbation expansion. (author)

  17. Coagulation function of stored whole blood is preserved for 14 days in austere conditions: A ROTEM feasibility study during a Norwegian antipiracy mission and comparison to equal ratio reconstituted blood.

    Science.gov (United States)

    Strandenes, Geir; Austlid, Ivar; Apelseth, Torunn O; Hervig, Tor A; Sommerfelt-Pettersen, Jan; Herzig, Maryanne C; Cap, Andrew P; Pidcoke, Heather F; Kristoffersen, Einar K

    2015-06-01

    Formulation of a medical preparedness plan for treating severely bleeding casualties during naval deployment is a significant challenge because of territory covered during most missions. The aim of this study was to evaluate the concept of "walking blood bank" as a supportable plan for supplying safe blood and blood products. In 2013, the Royal Norwegian Navy conducted antipiracy operations from a frigate, beginning in the Gulf of Aden and ending in the Indian Ocean. Crews were on 24-hour emergency alert in preparation for an enemy assault on the frigate. Under an approved command protocol, a "walking blood bank," using crew blood donations, was established for use on board and on missions conducted in rigid-hulled inflatable boats, during which freeze-dried plasma and leukoreduced, group O low anti-A/anti-B titer, cold-stored whole blood were stored in Golden Hour Boxes. Data demonstrating the ability to collect, store, and provide whole blood were collected to establish feasibility of implementing a whole blood-focused remote damage-control resuscitation program aboard a naval vessel. In addition, ROTEM data were collected to demonstrate feasibility of performing this analysis on a large naval vessel and to also measure hemostatic efficacy of cold-stored leukoreduced whole blood (CWB) stored during a period of 14 days. ROTEM data on CWB was compared with reconstituted whole blood. Drills simulating massive transfusion activation were conducted, in which 2 U of warm fresh whole blood with platelet sparing leukoreduction were produced in 40 minutes, followed by collection of two additional units at 15-minute increments. The ROTEM machine performed well during ship-rolling, as shown by the overlapping calculated and measured mechanical piston movements measured by the ROTEM device. Error messages were recorded in 4 (1.5%) of 267 tests. CWB yielded reproducible ROTEM results demonstrating preserved fibrinogen function and platelet function for at least 3.5 weeks and

  18. Prospects of Vitamin C as an Additive in Plasma of Stored Blood

    Directory of Open Access Journals (Sweden)

    R. Vani

    2015-01-01

    Full Text Available There is a dire necessity to improve blood storage and prolong shelf-life of blood. Very few studies have focused on oxidative stress (OS in blood and its influence on plasma with storage. This study attempts to (i elucidate the continuous changes occurring in plasma during storage through oxidant levels and antioxidant status and (ii evaluate the influence of vitamin C (VC as an additive during blood storage. Blood was drawn from male Wistar rats and stored for 25 days at 4°C. Blood samples were divided into control and experimental groups. Plasma was isolated every 5 days and the OS markers, antioxidant enzymes, lipid peroxidation, and protein oxidation products, were studied. Catalase activity increased in all groups with storage. Lipid peroxidation decreased in VC (10 but was maintained in VC (30 and VC (60. Although there were variations in all groups, carbonyls were maintained towards the end of storage. Advanced oxidation protein products (AOPP increased in VC (30 and were maintained in VC (10 and VC (60. Sulfhydryls were maintained in all groups. Vitamin C could not sufficiently attenuate OS and hence, this opens the possibilities for further studies on vitamin C in combination with other antioxidants, in storage solutions.

  19. Time-Course Investigation of Small Molecule Metabolites in MAP-Stored Red Blood Cells Using UPLC-QTOF-MS

    Directory of Open Access Journals (Sweden)

    Yong Zhou

    2018-04-01

    Full Text Available Red blood cells (RBCs are routinely stored for 35 to 42 days in most countries. During storage, RBCs undergo biochemical and biophysical changes known as RBC storage lesion, which is influenced by alternative storage additive solutions (ASs. Metabolomic studies have been completed on RBCs stored in a number of ASs, including SAGM, AS-1, AS-3, AS-5, AS-7, PAGGGM, and MAP. However, the reported metabolome analysis of laboratory-made MAP-stored RBCs was mainly focused on the time-dependent alterations in glycolytic intermediates during storage. In this study, we investigated the time-course of alterations in various small molecule metabolites in RBCs stored in commercially used MAP for 49 days using ultra-high performance liquid chromatography quadruple time-of-flight mass spectrometry (UPLC-QTOF-MS. These alterations indicated that RBC storage lesion is related to multiple pathways including glycolysis, pentose phosphate pathway, glutathione homeostasis, and purine metabolism. Thus, our findings might be useful for understanding the complexity of metabolic mechanisms of RBCs in vitro aging and encourage the deployment of systems biology methods to blood products in transfusion medicine.

  20. Serial transmission of human T-cell leukemia virus type I by blood transfusion in rabbits and its prevention by use of X-irradiated stored blood

    Energy Technology Data Exchange (ETDEWEB)

    Kotani, S.; Yoshimoto, S.; Yamato, K.; Fujishita, M.; Yamashita, M.; Ohtsuki, Y.; Taguchi, H.; Miyoshi, I.

    1986-06-15

    Human T-cell leukemia virus type I (HTLV-I) was serially transmitted for 5 passages from rabbit to rabbit by blood transfusion. The virus could be transmitted with 20 ml of whole blood or washed blood cell suspension (fresh or stored for 1-2 weeks at 4 degrees C) but not with cell-free plasma from seroconverted rabbits. Seroconversion occurred 2-4 weeks after blood transfusion and serum anti-HTLV-I titers ranged from 1:20 to 1:640 with the immunofluorescence assay. From transfusion recipients of the 1st to 4th passages, virus-producing cell lines were established by culturing lymphocytes in the presence of T-cell growth factor (TCGF). Three of the 4 cell lines became TCGF-independent after 2-12 months of continuous culture. Blood was transfused between rabbits of opposite sexes and the recipient origin of each cell line was determined by chromosome analysis. We also investigated the effect of X-irradiation (6,000 rad) on blood from seropositive rabbits. Seroconversion likewise occurred in rabbits transfused with blood that had been irradiated immediately before transfusion but not in rabbits transfused with blood that had been irradiated and stored for 1-2 weeks at 4 degrees C. Thus, our rabbit model shows that HTLV-I is serially transmissible by blood transfusion and that this can be prevented by irradiation of blood. The same procedure, therefore, may be useful for the prevention of transfusion-related transmission of HTLV-I in humans.

  1. Urinary di-(2-ethylhexyl) phthalate metabolites for detecting transfusion of autologous blood stored in plasticizer-free bags.

    Science.gov (United States)

    Leuenberger, Nicolas; Barras, Laura; Nicoli, Raul; Robinson, Neil; Baume, Norbert; Lion, Niels; Barelli, Stefano; Tissot, Jean-Daniel; Saugy, Martial

    2016-03-01

    Autologous blood transfusion (ABT) efficiently increases sport performance and is the most challenging doping method to detect. Current methods for detecting this practice center on the plasticizer di(2-ethlyhexyl) phthalate (DEHP), which enters the stored blood from blood bags. Quantification of this plasticizer and its metabolites in urine can detect the transfusion of autologous blood stored in these bags. However, DEHP-free blood bags are available on the market, including n-butyryl-tri-(n-hexyl)-citrate (BTHC) blood bags. Athletes may shift to using such bags to avoid the detection of urinary DEHP metabolites. A clinical randomized double-blinded two-phase study was conducted of healthy male volunteers who underwent ABT using DEHP-containing or BTHC blood bags. All subjects received a saline injection for the control phase and a blood donation followed by ABT 36 days later. Kinetic excretion of five urinary DEHP metabolites was quantified with liquid chromatography coupled with tandem mass spectrometry. Surprisingly, considerable levels of urinary DEHP metabolites were observed up to 1 day after blood transfusion with BTHC blood bags. The long-term metabolites mono-(2-ethyl-5-carboxypentyl) phthalate and mono-(2-carboxymethylhexyl) phthalate were the most sensitive biomarkers to detect ABT with BTHC blood bags. Levels of DEHP were high in BTHC bags (6.6%), the tubing in the transfusion kit (25.2%), and the white blood cell filter (22.3%). The BTHC bag contained DEHP, despite being labeled DEHP-free. Urinary DEHP metabolite measurement is a cost-effective way to detect ABT in the antidoping field even when BTHC bags are used for blood storage. © 2015 AABB.

  2. Pleomorphic Structures in Human Blood Are Red Blood Cell-Derived Microparticles, Not Bacteria.

    Science.gov (United States)

    Mitchell, Adam J; Gray, Warren D; Schroeder, Max; Yi, Hong; Taylor, Jeannette V; Dillard, Rebecca S; Ke, Zunlong; Wright, Elizabeth R; Stephens, David; Roback, John D; Searles, Charles D

    2016-01-01

    Red blood cell (RBC) transfusions are a common, life-saving therapy for many patients, but they have also been associated with poor clinical outcomes. We identified unusual, pleomorphic structures in human RBC transfusion units by negative-stain electron microscopy that appeared identical to those previously reported to be bacteria in healthy human blood samples. The presence of viable, replicating bacteria in stored blood could explain poor outcomes in transfusion recipients and have major implications for transfusion medicine. Here, we investigated the possibility that these structures were bacteria. Flow cytometry, miRNA analysis, protein analysis, and additional electron microscopy studies strongly indicated that the pleomorphic structures in the supernatant of stored RBCs were RBC-derived microparticles (RMPs). Bacterial 16S rDNA PCR amplified from these samples were sequenced and was found to be highly similar to species that are known to commonly contaminate laboratory reagents. These studies suggest that pleomorphic structures identified in human blood are RMPs and not bacteria, and they provide an example in which laboratory contaminants may can mislead investigators.

  3. Biofabricated film with enzymatic and redox-capacitor functionalities to harvest and store electrons

    International Nuclear Information System (INIS)

    Liba, Benjamin D; Kim, Eunkyoung; Martin, Alexandra N; Liu Yi; Bentley, William E; Payne, Gregory F

    2013-01-01

    Exciting opportunities in bioelectronics will be facilitated by materials that can bridge the chemical logic of biology and the digital logic of electronics. Here we report the fabrication of a dual functional hydrogel film that can harvest electrons from its chemical environment and store these electrons by switching the film's redox-state. The hydrogel scaffold was formed by the anodic deposition of the aminopolysaccharide chitosan. Electron-harvesting function was conferred by co-depositing the enzyme glucose dehydrogenase (GDH) with chitosan. GDH catalyzes the transfer of electrons from glucose to the soluble redox-shuttle NADP + . Electron-storage function was conferred by the redox-active food phenolic chlorogenic acid (CA) that was enzymatically grafted to the chitosan scaffold using tyrosinase. The grafted CA undergoes redox-cycling reactions with NADPH resulting in the net transfer of electrons to the film where they are stored in the reduced state of CA. The individual and dual functionalities of these films were demonstrated experimentally. There are three general conclusions from this proof-of-concept study. First, enzymatically-grafted catecholic moieties confer redox-capacitor function to the chitosan scaffold. Second, biological materials (i.e. chitosan and CA) and mechanisms (i.e. tyrosinase-mediated grafting) allow the reagentless fabrication of functional films that should be environmentally-friendly, safe and potentially even edible. Finally, the film's ability to mediate the transfer of electrons from a biological metabolite to an electrode suggests an approach to bridge the chemical logic of biology with the digital logic of electronics. (paper)

  4. Measurement of adenosine triphosphate and 2,3-diphosphoglycerate in stored blood with 31P nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Ambruso, D R; Hawkins, B; Johnson, D L; Fritzberg, A R; Klingensmith, W C; McCabe, E R

    1986-06-01

    Conditions for blood storage are chosen to assure adequate levels of adenosine triphosphate (ATP) and 2,3-diphosphoglycerate (2,3-DPG). Because of the invasive nature of the techniques, biochemical assays are not routinely used to measure levels of these compounds in stored blood. However, 31P NMR spectroscopy measures phosphorylated intermediates in intact cells and could be used without disruption of the storage pack. We compared levels of ATP and 2,3-DPG measured by 31P spectroscopy and standard enzyme-linked biochemical assays in whole blood (WB) and packed red blood cells (PRBCs) at weekly intervals during a 35-day storage period. NMR demonstrated a marked decrease in 2,3-DPG and an increase in inorganic phosphate after the first week of storage. No significant differences in ATP concentrations were seen in WB during the storage period, but a significant decrease in ATP in PRBCs was documented. There was good agreement in levels of ATP and 2,3-DPG measured by NMR and biochemical techniques. 31P NMR spectroscopy is a noninvasive technique for measuring ATP and 2,3-DPG which has a potential use in quality assurance of stored blood.

  5. The stability of iso-α-acids and reduced iso-α-acids in stored blood specimens.

    Science.gov (United States)

    Rodda, Luke N; Gerostamoulos, Dimitri; Drummer, Olaf H

    2014-06-01

    The long-term stability of the iso-α-acids, and three structurally similar but chemically altered iso-α-acids (known as 'reduced iso-α-acids' and consisting of the rho-, tetrahydro- and hexahydro-iso-α-acid groups) were investigated in whole blood. Pools of blank blood spiked with the four beer-specific ingredient congener groups at two different concentration levels were stored at 20°C, 4°C and -20°C; and extracted in duplicate in weeks 1, 3, 5 and 8, using a previously published method. A loss of 15% of the initial concentration was considered to indicate possible instability and losses greater than 30% demonstrated significant losses. The individual analytes within the four iso-α-acid groups were also measured to determine which iso-α-acids were subject to greater degradation and were responsible for the overall group instability. All four iso-α-acid groups showed significant losses after 8 weeks of storage under room temperature conditions in particularly the natural iso-α-acid group where major losses were observed (96% and 85% losses for low and high concentrations, respectively). Some degradation in all iso-α-acid groups were seen at 4°C samples predominantly due to the 'n' analogs of the groups showing an increased instability in blood. The -20°C storage conditions resulted in minimal changes in concentrations of all analytes. Higher than frozen storage temperatures can result in substantial changes on the stability of the iso-α-acid type groups in blood. The aim of this study was to highlight the stabilities of the IAA analytes in order to assist in the interpretation of IAA in stored blood specimens. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Donating umbilical cord blood to a public bank or storing it in a private bank: knowledge and preference of blood donors and of pregnant women.

    Science.gov (United States)

    Screnci, Maria; Murgi, Emilia; Pirrè, Guglielma; Valente, Elisabetta; Gesuiti, Paola; Corona, Francesca; Girelli, Gabriella

    2012-07-01

    Umbilical cord blood (UCB) is a source of stem cells for allogeneic haematopoietic transplantation in paediatric and adult patients with haematological malignancies and other indications. Voluntary donation is the basis for the success of unrelated UCB transplantation programmes. In the last few years a growing number of private banks offer their services to expectant parents, to store UCB for future use. The debate concerning UCB donation and private preservation has been ongoing for several years. The aims of this single centre study were to explore knowledge about UCB stem cells and attitudes towards voluntary UCB donation or private UCB preservation among both blood donors and pregnant women. This study was conducted at the "Sapienza" University of Rome. Two types of anonymous questionnaires were prepared: one type was administered to 1,000 blood donors while the other type was distributed to 300 pregnant women. Most blood donors as well as the majority of pregnant women had some general knowledge about UCB (89% and 93%, respectively) and were aware of the possibility of donating it (82% and 95%). However, the level of knowledge regarding current therapeutic use resulted generally low, only 91 (10%) among informed blood donors and 69 (31%) among informed pregnant women gave a correct answer. The survey revealed a preference for voluntary donation both among blood donors (76%) and among pregnant woman (55%). Indeed, a minority of blood donors (6.5%) and of pregnant women (9%) would opt to store UCB for private use. The study raises the following considerations: (i) the large support for UCB donation expressed by blood donors and by pregnant women suggests that UCB preservation does not represent an obstacle to the expansion of UCB donation and to development of unrelated transplantation programmes; (ii) information about UCB donation and preservation should be carefully given by professionals and institutions.

  7. An observational study of compliance with North Dakota's smoke-free law among retail stores that sell electronic smoking devices.

    Science.gov (United States)

    Buettner-Schmidt, Kelly; Miller, Donald R

    2017-07-01

    To determine whether retail stores selling electronic smoking devices or liquid nicotine were compliant with North Dakota's smoke-free law. During June 2015, retail stores selling electronic smoking devices or liquid nicotine (n=16), but not legally required to be licensed to sell tobacco products, were assessed for compliance with North Dakota's smoke-free law by observing for smoking or e-smoking, or evidence of such, in prohibited areas and for the presence of required no-smoking signs. Use of e-cigarettes, or evidence of use, was observed inside 8 (50%) stores required to be smoke-free. On the basis of all indicators of compliance assessed, compliance with the state's smoke-free law was low, with only 6% and 44% of stores compliant with all indoor and outdoor requirements, respectively. To the best of our knowledge, this is the first U.S. study assessing retail stores selling electronic smoking devices or liquid nicotine for compliance with the smoke-free law. The use of e-cigarettes, or evidence of use, occurred in the stores where it is prohibited by law. Overall compliance with the smoke-free law was low. These stores should be licensed by the state, as are other tobacco retailers, because this may assist in education, enforcement and compliance with the law and increase public health protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Detection of African Swine Fever Virus DNA in Blood Samples Stored on FTA Cards from Asymptomatic Pigs in Mbeya Region, Tanzania

    DEFF Research Database (Denmark)

    Braae, U. C.; Johansen, M. V.; Ngowi, H. A.

    2015-01-01

    The aim of the study was to assess whether blood samples collected onto FTA® cards could be used in combination with real-time PCR for the detection of African swine fever virus (ASFV) DNA in samples from resource-poor settings under the assumption that asymptomatically (sub-clinically) infected...... pigs may be present. Blood samples were collected from clinically healthy pigs from Mbeya Region, Tanzania. The blood samples were stored on FTA® cards and analysed by real-time PCR assays in duplicate; three pigs had high levels of viral DNA (Ct values of 27-29), and three pigs had a low level....../1) or a non-pathogenic (OURT T88/3) isolate of ASFV were collected, stored on FTA® cards and analysed in the same way. The blood from pigs infected with the OURT T88/1 isolate showed high levels of viral DNA (Ct 22-33), whereas infection with non-pathogenic OURT T88/3 isolate resulted in only low levels...

  9. High DNA stability in white blood cells and buffy coat lysates stored at ambient temperature under anoxic and anhydrous atmosphere

    Science.gov (United States)

    Luis, Aurélie; Colotte, Marthe; Tuffet, Sophie; Bonnet, Jacques

    2017-01-01

    Conventional storage of blood-derived fractions relies on cold. However, lately, ambient temperature preservation has been evaluated by several independent institutions that see economic and logistic advantages in getting rid of the cold chain. Here we validated a novel procedure for ambient temperature preservation of DNA in white blood cell and buffy coat lysates based on the confinement of the desiccated biospecimens under anoxic and anhydrous atmosphere in original hermetic minicapsules. For this validation we stored encapsulated samples either at ambient temperature or at several elevated temperatures to accelerate aging. We found that DNA extracted from stored samples was of good quality with a yield of extraction as expected. Degradation rates were estimated from the average fragment size of denatured DNA run on agarose gels and from qPCR reactions. At ambient temperature, these rates were too low to be measured but the degradation rate dependence on temperature followed Arrhenius’ law, making it possible to extrapolate degradation rates at 25°C. According to these values, the DNA stored in the encapsulated blood products would remain larger than 20 kb after one century at ambient temperature. At last, qPCR experiments demonstrated the compatibility of extracted DNA with routine DNA downstream analyses. Altogether, these results showed that this novel storage method provides an adequate environment for ambient temperature long term storage of high molecular weight DNA in dehydrated lysates of white blood cells and buffy coats. PMID:29190767

  10. High DNA stability in white blood cells and buffy coat lysates stored at ambient temperature under anoxic and anhydrous atmosphere.

    Directory of Open Access Journals (Sweden)

    Anne-Lise Fabre

    Full Text Available Conventional storage of blood-derived fractions relies on cold. However, lately, ambient temperature preservation has been evaluated by several independent institutions that see economic and logistic advantages in getting rid of the cold chain. Here we validated a novel procedure for ambient temperature preservation of DNA in white blood cell and buffy coat lysates based on the confinement of the desiccated biospecimens under anoxic and anhydrous atmosphere in original hermetic minicapsules. For this validation we stored encapsulated samples either at ambient temperature or at several elevated temperatures to accelerate aging. We found that DNA extracted from stored samples was of good quality with a yield of extraction as expected. Degradation rates were estimated from the average fragment size of denatured DNA run on agarose gels and from qPCR reactions. At ambient temperature, these rates were too low to be measured but the degradation rate dependence on temperature followed Arrhenius' law, making it possible to extrapolate degradation rates at 25°C. According to these values, the DNA stored in the encapsulated blood products would remain larger than 20 kb after one century at ambient temperature. At last, qPCR experiments demonstrated the compatibility of extracted DNA with routine DNA downstream analyses. Altogether, these results showed that this novel storage method provides an adequate environment for ambient temperature long term storage of high molecular weight DNA in dehydrated lysates of white blood cells and buffy coats.

  11. Centrifugation-free washing: A novel approach for removing immunoglobulin A from stored red blood cells.

    Science.gov (United States)

    Vörös, Eszter; Piety, Nathaniel Z; Strachan, Briony C; Lu, Madeleine; Shevkoplyas, Sergey S

    2018-08-01

    Washed red blood cells (RBCs) are indicated for immunoglobulin A (IgA) deficient recipients. Centrifugation-based cell processors commonly used by hospital blood banks cannot consistently reduce IgA below the recommended levels, hence double washing is frequently required. Here, we describe a prototype of a simple, portable, disposable system capable of washing stored RBCs without centrifugation, while reducing IgA below 0.05 mg/dL in a single run. Samples from RBC units (n = 8, leukoreduced, 4-6 weeks storage duration) were diluted with normal saline to a hematocrit of 10%, and then washed using either the prototype washing system, or via conventional centrifugation. The efficiency of the two washing methods was quantified and compared by measuring several key in vitro quality metrics. The prototype of the washing system was able to process stored RBCs at a rate of 300 mL/hour, producing a suspension of washed RBCs with 43 ± 3% hematocrit and 86 ± 7% cell recovery. Overall, the two washing methods performed similarly for most measured parameters, lowering the concentration of free hemoglobin by >4-fold and total free protein by >10-fold. Importantly, the new washing system reduced the IgA level to 0.02 ± 0.01 mg/mL, a concentration 5-fold lower than that produced by conventional centrifugation. This proof-of-concept study showed that centrifugation may be unnecessary for washing stored RBCs. A simple, disposable, centrifugation-free washing system could be particularly useful in smaller medical facilities and resource limited settings that may lack access to centrifugation-based cell processors. © 2017 Wiley Periodicals, Inc.

  12. In vivo viability of stored red blood cells derived from riboflavin plus ultraviolet light-treated whole blood.

    Science.gov (United States)

    Cancelas, Jose A; Rugg, Neeta; Fletcher, Dana; Pratt, P Gayle; Worsham, D Nicole; Dunn, Susan K; Marschner, Susanne; Reddy, Heather L; Goodrich, Raymond P

    2011-07-01

    A novel system using ultraviolet (UV) light and riboflavin (Mirasol System, CaridianBCT Biotechnologies) to fragment nucleic acids has been developed to treat whole blood (WB), aiming at the reduction of potential pathogen load and white blood cell inactivation. We evaluated stored red blood cell (RBC) metabolic status and viability, in vitro and in vivo, of riboflavin/UV light-treated WB (IMPROVE study). The study compared recovery and survival of RBCs obtained from nonleukoreduced WB treated using three different UV light energies (22, 33, or 44 J/mL(RBC)). After treatment, WB from 12 subjects was separated into components and tested at the beginning and end of component storage. After 42 days of storage, an aliquot of RBCs was radiolabeled and autologously reinfused into subjects for analysis of 24-hour recovery and survival of RBCs. Eleven subjects completed the in vivo study. No device-related adverse events were observed. By Day 42 of storage, a significant change in the concentrations of sodium and potassium was observed. Five subjects had a 24-hour RBC recovery of 75% or more with no significant differences among the energy groups. RBC t(1/2) was 24 ± 9 days for the combined three groups. Significant correlations between 24-hour RBC recovery and survival, hemolysis, adenosine triphosphate (ATP), and CO(2) levels were observed. This study shows that key RBC quality variables, hemolysis, and ATP concentration may be predictive of their 24-hour recovery and t(1/2) survival. These variables will now be used to assess modifications to the system including storage duration, storage temperature, and appropriate energy dose for treatment. © 2011 American Association of Blood Banks.

  13. An elapsed time-temperature monitor for blood storage.

    Science.gov (United States)

    Harris, G E; Cloud, S; Myhre, B A

    1977-01-01

    Blood should not be allowed to exceed 10 C while being stored or transported. However, one cannot test the internal temperature of a unit of blood without contaminating it. Most blood banks have established an arbitrary time limit beyond which a blood unit cannot be kept out of the refrigerator. This method is ineffective if blood is stored in a satellite refrigerator, since the blood may be moved in and out of the refrigerator and the blood bank personnel will be unaware of it. An elapsed time indicator is described which employs a small condenser (E-Cell-Plessey Electronics) charged with a known amount of electricity. If the device is removed from the refrigerator, it begins to discharge at a known rate. The amount of time subsequently can be determined by the loss of charge. The prototype of this instrument has been found to be quite accurate and small (2 inches X 2 inches X 1 inch). It would be rather inexpensive if made in considerable numbers.

  14. The miRNA Profile of Platelets Stored in a Blood Bank and Its Relation to Cellular Damage from Storage.

    Directory of Open Access Journals (Sweden)

    Thaís Brilhante Pontes

    Full Text Available Millions of blood products are transfused each year, and many lives are directly affected by transfusion. Platelet concentrate (PC is one of the main products derived from blood. Even under good storage conditions, PC is likely to suffer cell damage. The shape of platelets changes after 5 to 7 days of storage at 22°C. Taking into consideration that some platelet proteins undergo changes in their shape and functionality during PC storage. Sixteen PC bags were collected and each PC bag tube was cut into six equal pieces to perform experiments with platelets from six different days of storage. Thus, on the first day of storage, 1/6 of the tube was used for miRNA extraction, and the remaining 5/6 was stored under the same conditions until extraction of miRNAs on each the following five days. Samples were sequenced on an Illumina Platform to demonstrate the most highly expressed miRNAs. Three miRNAs, mir127, mir191 and mir320a were validated by real-time quantitative PCR (RQ-PCR in 100 PC bags tubes. Our method suggests, the use of the miRNAs mir127 and mir320a as biomarkers to assess the "validity period" of PC bags stored in blood banks for long periods. Thus, bags can be tested on the 5th day of storage for the relative expression levels of mir127 and mir320a. Thus, we highlight candidate miRNAs as biomarkers of storage damage that can be used as tools to evaluate the quality of stored PC. The use of miRNAs as biomarkers of damage is unprecedented and will contribute to improved quality of blood products for transfusions.

  15. Electronic remote blood issue: a combination of remote blood issue with a system for end-to-end electronic control of transfusion to provide a "total solution" for a safe and timely hospital blood transfusion service.

    Science.gov (United States)

    Staves, Julie; Davies, Amanda; Kay, Jonathan; Pearson, Oliver; Johnson, Tony; Murphy, Michael F

    2008-03-01

    The rapid provision of red cell (RBC) units to patients needing blood urgently is an issue of major importance in transfusion medicine. The development of electronic issue (sometimes termed "electronic crossmatch") has facilitated rapid provision of RBC units by avoidance of the serologic crossmatch in eligible patients. A further development is the issue of blood under electronic control at blood refrigerator remote from the blood bank. This study evaluated a system for electronic remote blood issue (ERBI) developed as an enhancement of a system for end-to-end electronic control of hospital transfusion. Practice was evaluated before and after its introduction in cardiac surgery. Before the implementation of ERBI, the median time to deliver urgently required RBC units to the patient was 24 minutes. After its implementation, RBC units were obtained from the nearby blood refrigerator in a median time of 59 seconds (range, 30 sec to 2 min). The study also found that unused requests were reduced significantly from 42 to 20 percent, the number of RBC units issued reduced by 52 percent, the number of issued units that were transfused increased from 40 to 62 percent, and there was a significant reduction in the workload of both blood bank and clinical staff. This study evaluated a combination of remote blood issue with an end-to-end electronically controlled hospital transfusion process, ERBI. ERBI reduced the time to make blood available for surgical patients and improved the efficiency of hospital transfusion.

  16. Electron beam potential measurements on an inductive-store, opening-switch accelerator

    International Nuclear Information System (INIS)

    Riordan, J.C.; Goyer, J.R.; Kortbawi, D.; Meachum, J.S.; Mendenhall, R.S.; Roth, I.S.

    1993-01-01

    Direct measurement of the accelerating potential in a relativistic electron beam accelerator is difficult, particularly when the diode is downstream from a plasma opening switch. An indirect potential measurement can be obtained from the high energy tail of the bremsstrahlung spectrum generated as the electron beam strikes the anode. The authors' time-resolved spectrometer contains 7 silicon pin diode detectors filtered with 2 to 15 mm of lead to span an electron energy range of 0.5 to 2 MeV. A Monte-Carlo transport code was used to provide calibration curves, and the resulting potential measurements have been confirmed in experiments on the PITHON accelerator. The spectrometer has recently been deployed on PM1, an inductive-store, opening-switch testbed. The diode voltage measurements from the spectrometer are in good agreement with the diode voltage measured upstream and corrected using transmission line relations. The x-ray signal and spectral voltage rise 10 ns later than the corrected electrical voltage, however, indicating plasma motion between the opening switch and the diode

  17. Ammonia concentration and bacterial evaluation of feline whole blood and packed red blood cell units stored for transfusion

    Directory of Open Access Journals (Sweden)

    Eva Spada

    2014-10-01

    Full Text Available Ammonia concentrations increase in human, canine and equine WB and PRBC units during storage. The aim of this study was to determine the effect of storage on ammonia concentration in feline WB and PRBC units stored in a veterinary blood bank and to evaluate possible correlations with bacterial contamination. Ammonia concentration was evaluated in 15 WB units and 2 PRBC units on day 1 and at the end of storage after 35 and 42 days, respectively. In an additional 5 WB units and 4 PRBC units ammonia concentrations were determined daily until the day the normal reference range was exceeded and then weekly to the end of storage. All units were evaluated for bacterial contamination. Ammonia increased markedly during storage as a linear function over time. On the 35th and 42th day of storage at 4±2°C mean±SD ammonia concentration reached 909±158 µg/dl and 1058±212 µg/dl in WB and PRBC units, respectively. Bacterial culture was negative in all units. High ammonia concentrations in stored WB and PRBC units could result in toxicity, particularly in feline recipients with liver failure, portosystemic shunts or those receiving large transfusion volumes. Clinical in vivo studies evaluating the effects on recipients should be performed.

  18. Stored blood--an effective immunosuppressive method for transplantation of kidneys from unrelated donors. An 11-year follow-up.

    Science.gov (United States)

    Galvão, M M; Peixinho, Z F; Mendes, N F; Sabbaga, E

    1997-06-01

    Thirty-seven patients were submitted to kidney transplantation after transfusion at 2-week intervals with 4-week stored blood from their potential donors. All patients and donors were typed for HLA-A-B and DR antigens. The patients were also tested for cytotoxic antibodies against donor antigens before each transfusion. The percentage of panel reactive antibodies (PRA) was determined against a selected panel of 30 cell donors before and after the transfusions. The patients were immunosuppressed with azathioprine and prednisone. Rejection crises were treated with methylprednisolone. The control group consisted of 23 patients who received grafts from an unrelated donor but who did not receive donor-specific pretransplant blood transfusion. The incidence and reversibility of rejection episodes, allograft loss caused by rejection, and patient and graft survival rates were determined for both groups. Non-parametric methods (chi-square and Fisher tests) were used for statistical analysis, with the level of significance set at P transplant days did not differ significantly between groups. The actuarial graft and patient survival rates at five years were 56% and 77%, respectively, for the treated group and 39.8% and 57.5% for the control group. Graft loss due to rejection was significantly higher in the untreated group (P = 0.0026) which also required more intense immunosuppression (P = 0.0001). We conclude that transfusions using stored blood have the immunosuppressive effect of fresh blood transfusions without the risk of provoking a widespread formation of antibodies. In addition, this method permits a reduction of the immunosuppressive drugs during the process without impairing the adequate functioning of the renal graft.

  19. Rejuvenation of stored human red blood cells reverses the renal microvascular oxygenation deficit in an isovolemic transfusion model in rats

    NARCIS (Netherlands)

    Raat, Nicolaas J. H.; Hilarius, Petra M.; Johannes, Tanja; de Korte, Dirk; Ince, Can; Verhoeven, Arthur J.

    2009-01-01

    BACKGROUND: Storage of red blood cells (RBCs) results in various biochemical changes, including a decrease in cellular adenosine triphosphate and 2,3-diphosphoglycerate acid. Previously it was shown that stored human RBCs show a deficit in the oxygenation of the microcirculation in the gut of

  20. Whole-genome amplified DNA from stored dried blood spots is reliable in high resolution melting curve and sequencing analysis

    DEFF Research Database (Denmark)

    Winkel, Bo G; Hollegaard, Mads V; Olesen, Morten S

    2011-01-01

    BACKGROUND: The use of dried blood spots (DBS) samples in genomic workup has been limited by the relative low amounts of genomic DNA (gDNA) they contain. It remains to be proven that whole genome amplified DNA (wgaDNA) from stored DBS samples, constitutes a reliable alternative to gDNA.We wanted...

  1. Reintoxication: the release of fat-stored delta(9)-tetrahydrocannabinol (THC) into blood is enhanced by food deprivation or ACTH exposure.

    Science.gov (United States)

    Gunasekaran, N; Long, L E; Dawson, B L; Hansen, G H; Richardson, D P; Li, K M; Arnold, J C; McGregor, I S

    2009-11-01

    Delta(9)-tetrahydrocannabinol (THC), the main psychoactive constituent of cannabis, accumulates in adipose tissue where it is stored for long periods of time. Here we investigated whether conditions that promote lipolysis can liberate THC from adipocytes to yield increased blood levels of THC. In vitro studies involved freshly isolated rat adipocytes that were incubated with THC before exposure to the lipolytic agent adrenocorticotrophic hormone (ACTH). A complementary in vivo approach examined the effects of both food deprivation and ACTH on blood levels of THC in rats that had been repeatedly injected with THC (10 mg.kg(-1)) for 10 consecutive days. Lipolysis promoted by ACTH or food deprivation was indexed by measurement of glycerol levels. ACTH increased THC levels in the medium of THC-pretreated adipocytes in vitro. ACTH also enhanced THC release from adipocytes in vitro when taken from rats repeatedly pretreated with THC in vivo. Finally, in vivo ACTH exposure and 24 h food deprivation both enhanced the levels of THC and its metabolite, (-)-11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH) in the blood of rats that had been pre-exposed to repeated THC injections. The present study shows that lipolysis enhances the release of THC from fat stores back into blood. This suggests the likelihood of 'reintoxication' whereby food deprivation or stress may raise blood THC levels in animals chronically exposed to the drug. Further research will need to confirm whether this can lead to functional effects, such as impaired cognitive function or 'flashbacks'.

  2. Polarizing a stored proton beam by spin flip?

    International Nuclear Information System (INIS)

    Oellers, D.; Barion, L.; Barsov, S.; Bechstedt, U.; Benati, P.; Bertelli, S.; Chiladze, D.; Ciullo, G.; Contalbrigo, M.; Dalpiaz, P.F.; Dietrich, J.; Dolfus, N.; Dymov, S.; Engels, R.; Erven, W.; Garishvili, A.; Gebel, R.; Goslawski, P.

    2009-01-01

    We discuss polarizing a proton beam in a storage ring, either by selective removal or by spin flip of the stored ions. Prompted by recent, conflicting calculations, we have carried out a measurement of the spin-flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam. This invalidates a recent proposal to use co-moving polarized positrons to polarize a stored antiproton beam.

  3. Detection of African swine fever virus DNA in blood samples stored on FTA cards from asymptomatic pigs in Mbeya region, Tanzania.

    Science.gov (United States)

    Braae, U C; Johansen, M V; Ngowi, H A; Rasmussen, T B; Nielsen, J; Uttenthal, Å

    2015-02-01

    The aim of the study was to assess whether blood samples collected onto FTA(®) cards could be used in combination with real-time PCR for the detection of African swine fever virus (ASFV) DNA in samples from resource-poor settings under the assumption that asymptomatically (sub-clinically) infected pigs may be present. Blood samples were collected from clinically healthy pigs from Mbeya Region, Tanzania. The blood samples were stored on FTA(®) cards and analysed by real-time PCR assays in duplicate; three pigs had high levels of viral DNA (Ct values of 27-29), and three pigs had a low level of viral DNA (Ct 36-45). Four pigs were positive in one of the duplicate samples only, but clear products of the expected size were obtained when the reactions were analysed by gel electrophoresis. For comparison, blood samples from pigs experimentally infected with either a pathogenic (OURT T88/1) or a non-pathogenic (OURT T88/3) isolate of ASFV were collected, stored on FTA(®) cards and analysed in the same way. The blood from pigs infected with the OURT T88/1 isolate showed high levels of viral DNA (Ct 22-33), whereas infection with non-pathogenic OURT T88/3 isolate resulted in only low levels of viral DNA (Ct 39) in samples collected at 10-14 days after inoculation. © 2013 Blackwell Verlag GmbH.

  4. From manager's emotional intelligence to objective store performance: Through store cohesiveness and sales-directed employee behavior

    NARCIS (Netherlands)

    Wilderom, Celeste P.M.; Hur, YounHee; Wiersma, Uco J.; van den Berg, Peter T.; Lee, Jaehoon

    2015-01-01

    The relationships among manager's emotional intelligence, store cohesiveness, sales-directed employee behavior, and objective store performance were investigated. Non-managerial sales employees of a large retail electronics chain in South Korea (N = 1611) rated the emotional intelligence of their

  5. Influence of Pre-Storage Irradiation on the Oxidative Stress Markers, Membrane Integrity, Size and Shape of the Cold Stored Red Blood Cells.

    Science.gov (United States)

    Antosik, Adam; Czubak, Kamila; Gajek, Arkadiusz; Marczak, Agnieszka; Glowacki, Rafal; Borowczyk, Kamila; Zbikowska, Halina Malgorzata

    2015-05-01

    To investigate the extent of oxidative damage and changes in morphology of manually isolated red blood cells (RBCs) from whole blood, cold stored (up to 20 days) in polystyrene tubes and subjected to pre-storage irradiation (50 Gy) and to compare the properties of SAGM-preserved RBCs stored under experimental conditions (polystyrene tubes) with RBCs from standard blood bag storage. The percentage of hemolysis as well as the extracellular activity of LDH, thiobarbituric acid-reactive substances, reduced glutathione (GSH), and total antioxidant capacity (TAC) were measured. Changes in the topology of RBC membrane, shape, and size were evaluated by flow cytometry and judged against microscopy images. Irradiation caused significant LDH release as well as increased hemolysis and lipid peroxidation, GSH depletion, and reduction of TAC. Prolonged storage of irradiated RBCs resulted in phosphatidylserine exposure on the cell surface. By day 20, approximately 60% of RBCs displayed non-discoid shape. We did not notice significant differences in percentage of altered cells and cell volume between RBCs exposed to irradiation and those not exposed. Irradiation of RBC transfusion units with a dose of 50 Gy should be avoided. For research purposes such as studying the role of antioxidants, storage of small volumes of RBCs derived from the same donor would be more useful, cheaper, and blood-saving.

  6. The mechanical properties of stored red blood cells measured by a convenient microfluidic approach combining with mathematic model.

    Science.gov (United States)

    Wang, Ying; You, Guoxing; Chen, Peipei; Li, Jianjun; Chen, Gan; Wang, Bo; Li, Penglong; Han, Dong; Zhou, Hong; Zhao, Lian

    2016-03-01

    The mechanical properties of red blood cells (RBCs) are critical to the rheological and hemodynamic behavior of blood. Although measurements of the mechanical properties of RBCs have been studied for many years, the existing methods, such as ektacytometry, micropipette aspiration, and microfluidic approaches, still have limitations. Mechanical changes to RBCs during storage play an important role in transfusions, and so need to be evaluated pre-transfusion, which demands a convenient and rapid detection method. We present a microfluidic approach that focuses on the mechanical properties of single cell under physiological shear flow and does not require any high-end equipment, like a high-speed camera. Using this method, the images of stretched RBCs under physical shear can be obtained. The subsequent analysis, combined with mathematic models, gives the deformability distribution, the morphology distribution, the normalized curvature, and the Young's modulus (E) of the stored RBCs. The deformability index and the morphology distribution show that the deformability of RBCs decreases significantly with storage time. The normalized curvature, which is defined as the curvature of the cell tail during stretching in flow, suggests that the surface charge of the stored RBCs decreases significantly. According to the mathematic model, which derives from the relation between shear stress and the adherent cells' extension ratio, the Young's moduli of the stored RBCs are also calculated and show significant increase with storage. Therefore, the present method is capable of representing the mechanical properties and can distinguish the mechanical changes of the RBCs during storage. The advantages of this method are the small sample needed, high-throughput, and easy-use, which make it promising for the quality monitoring of RBCs.

  7. From manager’s emotional intelligence to objective store performance : Through store cohesiveness and sales-directed employee behavior

    NARCIS (Netherlands)

    Wilderom, C.P.M.; Hur, Y.; Wiersma, U.J.; van den Berg, Petrus; Lee, J.

    2015-01-01

    The relationships among manager's emotional intelligence, store cohesiveness, sales-directed employee behavior, and objective store performance were investigated. Non-managerial sales employees of a large retail electronics chain in South Korea (N = 1611) rated the emotional intelligence of their

  8. A modified Fricke gel dosimeter for fast electron blood dosimetry

    International Nuclear Information System (INIS)

    Del Lama, L.S.; Góes, E.G. de; Sampaio, F.G.A.; Petchevist, P.C.D.; Almeida, A. de

    2014-01-01

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXG p ) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXG p dosimeter were also able to provide isodose curves and field profiles for the irradiated samples

  9. A modified Fricke gel dosimeter for fast electron blood dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Del Lama, L.S., E-mail: lucasdellama@gmail.com [Departamento de Fsica, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP/USP), Av. Bandeirantes, 3900, CEP 14040-901, Bairro Monte Alegre, Ribeirão Preto, São Paulo (Brazil); Góes, E.G. de [Instituto de Matemática, Estatística e Física, Universidade Federal de Rio Grande (IMEF/FURG), Av. Itália, km 8, CEP 96201-900, Bairro Carreiros, Rio Grande, Rio Grande do Sul (Brazil); Sampaio, F.G.A.; Petchevist, P.C.D.; Almeida, A. de [Departamento de Fsica, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP/USP), Av. Bandeirantes, 3900, CEP 14040-901, Bairro Monte Alegre, Ribeirão Preto, São Paulo (Brazil)

    2014-12-15

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXG{sub p}) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXG{sub p} dosimeter were also able to provide isodose curves and field profiles for the irradiated samples.

  10. Age of blood and survival after massive transfusion.

    Science.gov (United States)

    Sanz, C C; Pereira, A

    2017-11-01

    Massive transfusion is the clinical scenario where the presumed adverse effects of stored blood are expected to be more evident because the whole patient's blood volume is replaced by stored blood. To analyse the association between age of transfused red blood cells (RBC) and survival in massively transfused patients. In this retrospective study, clinical and transfusion data of all consecutive patients massively transfused between 2008 and 2014 in a large, tertiary-care hospital were electronically extracted from the Transfusion Service database and the patients' electronic medical records. Prognostic factors for in-hospital mortality were investigated by multivariate logistic regression. A total of 689 consecutive patients were analysed (median age: 61 years; 65% males) and 272 died in-hospital. Projected mortality at 2, 30, and 90 days was 21%, 35% and 45%, respectively. The odds ratio (OR) for in-hospital mortality among patients who survived after the 2nd day increased with patient age (OR: 1.037, 95% CI: 1.021-1.054; per year Ptransfused in the first 48hours (OR: 1.060; 95% CI: 1.038-1.020 per unit; Ptransfusion was associated with a higher proportion of old RBCs transfused in the first 48hours. Other factors associated with poor prognosis were older patient's age and larger volumes of transfused RBCs. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Modified expression of surface glyconjugates in stored human platelets

    International Nuclear Information System (INIS)

    Dhar, A.; Ganguly, P.

    1987-01-01

    Platelets are anucleated cells which play an important part in blood coagulation and thrombosis. These cells may be stored in the blood bank for only 4/5 days. In order to improve the storage of platelets, it is essential to first understand the changes in these cells due to storage. In this work, human platelets were stored in autologous plasma at 4 0 or 22 0 and their surface changes were monitored with three lectins - wheat germ afflutinin (WGA), concanavalin A (Con A) and lentil lectin (LL). Blood was drawn from healthy donors and platelet rich plasma (PRP) was collected by slow speed centrifugation. Platelets stored at either temperature for different times showed increased sensitivity to agglutination by WGA after 34-48 hrs. Lectins, Con A and LL, which were not agglutinating to fresh platelets readily caused agglutination after 48-72 hrs. The platelets stored for 25 hrs or longer period were insensitive to thrombin but showed enhanced aggregation with WGA. Labelling of surface glycoconjugates of stored platelets with 3 H-boro-hydride revealed progressive loss of a glycoprotein of Mr 150,000 (GPIb infinity) together with the appearance of components of Mr 69,000; Mr 60,000; Mr 25,000. New high molecular weight glycoproteins were also detected only in stored platelets. The author studies clearly indicate that modification or altered expression of platelets surface glycoproteins may be one factor of storage related dysfunction of platelets

  12. Modified expression of surface glyconjugates in stored human platelets

    Energy Technology Data Exchange (ETDEWEB)

    Dhar, A.; Ganguly, P.

    1987-05-01

    Platelets are anucleated cells which play an important part in blood coagulation and thrombosis. These cells may be stored in the blood bank for only 4/5 days. In order to improve the storage of platelets, it is essential to first understand the changes in these cells due to storage. In this work, human platelets were stored in autologous plasma at 4/sup 0/ or 22/sup 0/ and their surface changes were monitored with three lectins - wheat germ afflutinin (WGA), concanavalin A (Con A) and lentil lectin (LL). Blood was drawn from healthy donors and platelet rich plasma (PRP) was collected by slow speed centrifugation. Platelets stored at either temperature for different times showed increased sensitivity to agglutination by WGA after 34-48 hrs. Lectins, Con A and LL, which were not agglutinating to fresh platelets readily caused agglutination after 48-72 hrs. The platelets stored for 25 hrs or longer period were insensitive to thrombin but showed enhanced aggregation with WGA. Labelling of surface glycoconjugates of stored platelets with /sup 3/H-boro-hydride revealed progressive loss of a glycoprotein of Mr 150,000 (GPIb infinity) together with the appearance of components of Mr 69,000; Mr 60,000; Mr 25,000. New high molecular weight glycoproteins were also detected only in stored platelets. The author studies clearly indicate that modification or altered expression of platelets surface glycoproteins may be one factor of storage related dysfunction of platelets.

  13. Post mortem concentrations of endogenous gamma hydroxybutyric acid (GHB) and in vitro formation in stored blood and urine samples.

    Science.gov (United States)

    Busardò, Francesco Paolo; Bertol, Elisabetta; Vaiano, Fabio; Baglio, Giovanni; Montana, Angelo; Barbera, Nunziata; Zaami, Simona; Romano, Guido

    2014-10-01

    Gamma-hydroxybutyrate (GHB) is a central nervous system depressant, primarily used as a recreational drug of abuse with numerous names. It has also been involved in various instances of drug-facilitated sexual assault due to its potential incapacitating effects. The first aim of this paper is to measure the post-mortem concentration of endogenous GHB in whole blood and urine samples of 30 GHB free-users, who have been divided according to the post-mortem interval (PMI) in three groups (first group: 24-36h; second group: 37-72h; third group: 73-192h), trying to evaluate the role of PMI in affecting post mortem levels. Second, the Authors have evaluated the new formation of GHB in vitro in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month. The concentrations were measured by GC-MS after liquid-liquid extraction according to the method validated and published by Elliot (For. Sci. Int., 2003). For urine samples, GHB concentrations were creatinine-normalized. In the first group the GHB mean concentration measured after autopsy was: 2.14mg/L (range 0.54-3.21mg/L) in blood and 3.90mg/g (range 0.60-4.81mg/g) in urine; in the second group it was: 5.13mg/L (range 1.11-9.60mg/L) in blood and 3.93mg/g (range 0.91-7.25mg/g) in urine; in the third group it was: 11.8mg/L (range 3.95-24.12mg/L) in blood and 9.83mg/g (range 3.67-21.90mg/g) in urine. The results obtained in blood and urine samples showed a statistically significant difference among groups (pblood and urine samples a mean difference at 20°C compared to -20°C not statistically significant at the 10% level. These findings allow us to affirm that the PMI strongly affects the post mortem production of GHB in blood and urine samples. Regarding the new formation of GHB in vitro both in blood and urine samples of the three groups, which have been stored at -20°C, 4°C and 20°C over a period of one month, although there was no significant increases of

  14. Comparison of blood RNA isolation methods from samples stabilized in Tempus tubes and stored at a large human biobank.

    Science.gov (United States)

    Aarem, Jeanette; Brunborg, Gunnar; Aas, Kaja K; Harbak, Kari; Taipale, Miia M; Magnus, Per; Knudsen, Gun Peggy; Duale, Nur

    2016-09-01

    More than 50,000 adult and cord blood samples were collected in Tempus tubes and stored at the Norwegian Institute of Public Health Biobank for future use. In this study, we systematically evaluated and compared five blood-RNA isolation protocols: three blood-RNA isolation protocols optimized for simultaneous isolation of all blood-RNA species (MagMAX RNA Isolation Kit, both manual and semi-automated protocols; and Norgen Preserved Blood RNA kit I); and two protocols optimized for large RNAs only (Tempus Spin RNA, and Tempus 6-port isolation kit). We estimated the following parameters: RNA quality, RNA yield, processing time, cost per sample, and RNA transcript stability of six selected mRNAs and 13 miRNAs using real-time qPCR. Whole blood samples from adults (n = 59 tubes) and umbilical cord blood (n = 18 tubes) samples collected in Tempus tubes were analyzed. High-quality blood-RNAs with average RIN-values above seven were extracted using all five RNA isolation protocols. The transcript levels of the six selected genes showed minimal variation between the five protocols. Unexplained differences within the transcript levels of the 13 miRNA were observed; however, the 13 miRNAs had similar expression direction and they were within the same order of magnitude. Some differences in the RNA processing time and cost were noted. Sufficient amounts of high-quality RNA were obtained using all five protocols, and the Tempus blood RNA system therefore seems not to be dependent on one specific RNA isolation method.

  15. Risk of iatrogenic human immunodeficiency virus infection through transfusion of blood tested by inappropriately stored or expired rapid antibody assays in a Zambian hospital

    NARCIS (Netherlands)

    Consten, E. C.; van der Meer, J. T.; de Wolf, F.; Heij, H. A.; Henny, P. C.; van Lanschot, J. J.

    1997-01-01

    BACKGROUND: The purpose of this study was to estimate the risk of human immunodeficiency virus (HIV) infection via the transfusion of blood tested by inappropriately stored or expired rapid antibody assays in Zambia. STUDY DESIGN AND METHODS: Surgical patients (n = 370) were tested with antibody

  16. Platelet concentrates stored in plasma for 72 hours at 22 degrees C prepared from buffycoats of citrate-phosphate-dextrose blood collected in a quadruple-bag saline-adenine-glucose-mannitol system

    NARCIS (Netherlands)

    Pietersz, R. N.; Loos, J. A.; Reesink, H. W.

    1985-01-01

    A method is described to prepare platelet concentrates from the buffycoat of citrate-phosphate-dextrose (CPD) blood in a closed four-bag system and to store the platelets in autologous plasma under sterile conditions. After separation of the blood into plasma, buffycoat and leukocyte- and

  17. Electron beam irradiation, oxygen, and temperature effects on nucleotide degradation in stored aquaculture hybrid striped bass fillets

    International Nuclear Information System (INIS)

    Karahadian, C.; Brannan, R.G.; Heath, J.L.

    1997-01-01

    Skinless fillets from commercially-grown aquaculture hybrid striped bass (Morone saxatilis x M. chrysops) were electron beam-irradiated in the presence of air or vacuum-packaged and stored at 4C and -20C for 14 days. A mean low dose level of 2.0 or 3.0 kGy (+/- 0.5 kGy) and high dose level of 20 kGy (+/- 4 kGy) were used for irradiated samples. Hypoxanthine (Hx) concentrations, Ki-values ([(INO + Hx)/(IMP + INO + Hx)] x 100), and H-values ([(Hx)/(IMP + INO + Hx)] x 100) indicated that irradiation did not influence the rate of nucleotide degradation compared with nonirradiated controls at either refrigerated or frozen temperatures. Vacuum packaging or freezing of stored samples resulted in lower H-values and Hx contents compared with nonirradiated controls regardless of irradiation treatment

  18. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    of whole blood samples at low temperatures and rapid isolation of plasma and serum. Effects of different handling procedures for all markers studied are given. DBSS proved to be a robust and convenient way to handle samples for immunoassay analysis of inflammatory markers in whole blood Udgivelsesdato......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  19. The Impact of an Electronic Ordering System on Blood Bank Specimen Rejection Rates.

    Science.gov (United States)

    Forest, Stefanie K; Shirazi, Maryam; Wu-Gall, Charlotte; Stotler, Brie A

    2017-01-01

    To evaluate the impact that an electronic ordering system has on the rate of rejection of blood type and screen testing samples and the impact on the number of ABO blood-type discrepancies over a 4-year period. An electronic ordering system was implemented in May 2011. Rejection rates along with reasons for rejection were tracked between January 2010 and December 2013. A total of 40,104 blood samples were received during this period, of which 706 (1.8%) were rejected for the following reasons: 382 (54.0%) unsigned samples, 235 (33.0%) mislabeled samples, 57 (8.0%) unsigned requisitions, 18 (2.5%) incorrect tubes, and 14 (1.9%) ABO discrepancies. Of the samples, 2.5% were rejected in the year prior to implementing the electronic ordering system compared with 1.2% in the year following implementation ( P  blood sample rejection. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  20. CO2 -dependent metabolic modulation in red blood cells stored under anaerobic conditions.

    Science.gov (United States)

    Dumont, Larry J; D'Alessandro, Angelo; Szczepiorkowski, Zbigniew M; Yoshida, Tatsuro

    2016-02-01

    Anaerobic red blood cell (RBC) storage reduces oxidative damage, maintains adenosine triphosphate (ATP) and 2,3-diphosphoglycerate (DPG) levels, and has superior 24-hour recovery at 6 weeks compared to standard storage. This study will determine if removal of CO2 during O2 depletion by gas exchange may affect RBCs during anaerobic storage. This is a matched three-arm study (n = 14): control, O2 and CO2 depleted with Ar (AN), and O2 depleted with 95%Ar/5%CO2 (AN[CO2 ]). RBCs in additives AS-3 or OFAS-3 were evenly divided into three bags, and anaerobic conditions were established by gas exchange. Bags were stored at 1 to 6°C in closed chambers under anaerobic conditions or ambient air, sampled weekly for up to 9 weeks for a panel of in vitro tests. A full metabolomics screening was conducted for the first 4 weeks of storage. Purging with Ar (AN) results in alkalization of the RBC and increased glucose consumption. The addition of 5% CO2 to the purging gas prevented CO2 loss with an equivalent starting and final pH and lactate to control bags (p > 0.5, Days 0-21). ATP levels are higher in AN[CO2 ] (p < 0.0001). DPG was maintained beyond 2 weeks in the AN arm (p < 0.0001). Surprisingly, DPG was lost at the same rate in both control and AN[CO2 ] arms (p = 0.6). Maintenance of ATP in the AN[CO2 ] arm demonstrates that ATP production is not solely a function of the pH effect on glycolysis. CO2 in anaerobic storage prevented the maintenance of DPG, and DPG production appears to be pH dependent. CO2 as well as O2 depletion provides metabolic advantage for stored RBCs. © 2015 AABB.

  1. Coagulation Function of Stored Whole Blood is Preserved for 14 Days in Austere Conditions: A ROTEM Feasibility Study During a Norwegian Antipiracy Mission and Comparison to Equal Ratio Reconstituted Blood

    Science.gov (United States)

    2015-06-24

    mechanical piston movements measured by the ROTEM device. Error messages were recorded in 4 (1.5%) of 267 tests. CWB yielded repro- ducible ROTEM results... piston movement analysis, error message frequency, and result variability and (2) compare the clotting properties of cold-stored WB obtained from a walking...signed the selection form, which tracked TTD screening and blood grouping results. That same form doubled as a transfusion form and was used to

  2. Time-dependent histamine release from stored human blood products

    DEFF Research Database (Denmark)

    Nielsen, Hans Jørgen; Edvardsen, L; Vangsgaard, K

    1996-01-01

    .0 (range 176.0-910.0) nmol/l in whole blood and 475.0 (range 360.0-1560.0) nmol/l in plasma-reduced whole blood, while it was undetectable in SAGM blood. Spontaneous histamine release increased in a time-dependent manner from a median of 6.7 (range 2.2-17.4) nmol/l at the time of storage to 175.0 (range 33...

  3. Cord Blood and Transplants

    Science.gov (United States)

    ... donate their baby’s umbilical cord blood to a public cord blood bank. We have more than 249,000 cord blood ... stored as a cord blood unit at a public cord blood bank for future use. It can then be listed ...

  4. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    OpenAIRE

    Daniel D. Reidpath; Mei Lee Ling; Shajahan Yasin; Kanason Rajagobal; Pascale Allotey

    2012-01-01

    Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers usin...

  5. The importance of store windows in creating store identity and store attractiveness

    Directory of Open Access Journals (Sweden)

    Renko Sanda

    2012-01-01

    Full Text Available While choosing the store, customer first notices the store window and it plays an important role in retailing strategy. Store's window is what customers see first in meeting with the store. Store window design can lead customer to enter the store, and can give a lot of information about store brands and products. Besides the analysis of the way how specific elements of the window design affect customers and their perception, the explanation of their attraction and rejection to customers is given. If we consider the importance of the topics, we can point out the lack of literature about store windows as the communication tool which allow store to communicate with its customers and to create its retailing strategy as well. There is the scientific contribution of this paper. The paper gives theoretical comprehensions completed with the results of the study about the importance of store windows for retailers as well as for customers. Therefore, for the purpose of this paper, a two-phase research study, including a qualitative and a quantitative approach, was used: 1 the qualitative study among retailers which indicated the most important elements of store windows, the level of financial sources invested in the window design, the basis for the decisions about store window design, etc.; 2 the quantitative study on the sample of consumers conducted with on-line questionnaire. Findings suggest that store window attractiveness is the main motif for store visits. The results of the research confirm that by means of store window and its elements (with special emphasis on price and pricing actions retail store sends messages to its consumers.

  6. Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.

    Science.gov (United States)

    Mohammadhoseini, Elham; Safavi, Enayat; Seifi, Sepideh; Seifirad, Soroush; Firoozbakhsh, Shahram; Peiman, Soheil

    2015-03-01

    Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.

  7. Ammonia synthesis using a stable electride as an electron donor and reversible hydrogen store

    Science.gov (United States)

    Kitano, Masaaki; Inoue, Yasunori; Yamazaki, Youhei; Hayashi, Fumitaka; Kanbara, Shinji; Matsuishi, Satoru; Yokoyama, Toshiharu; Kim, Sung-Wng; Hara, Michikazu; Hosono, Hideo

    2012-11-01

    Industrially, the artificial fixation of atmospheric nitrogen to ammonia is carried out using the Haber-Bosch process, but this process requires high temperatures and pressures, and consumes more than 1% of the world's power production. Therefore the search is on for a more environmentally benign process that occurs under milder conditions. Here, we report that a Ru-loaded electride [Ca24Al28O64]4+(e-)4 (Ru/C12A7:e-), which has high electron-donating power and chemical stability, works as an efficient catalyst for ammonia synthesis. Highly efficient ammonia synthesis is achieved with a catalytic activity that is an order of magnitude greater than those of other previously reported Ru-loaded catalysts and with almost half the reaction activation energy. Kinetic analysis with infrared spectroscopy reveals that C12A7:e- markedly enhances N2 dissociation on Ru by the back donation of electrons and that the poisoning of ruthenium surfaces by hydrogen adatoms can be suppressed effectively because of the ability of C12A7:e- to store hydrogen reversibly.

  8. Fluorescence Exclusion: A Simple Method to Assess Projected Surface, Volume and Morphology of Red Blood Cells Stored in Blood Bank

    Directory of Open Access Journals (Sweden)

    Camille Roussel

    2018-05-01

    Full Text Available Red blood cells (RBC ability to circulate is closely related to their surface area-to-volume ratio. A decrease in this ratio induces a decrease in RBC deformability that can lead to their retention and elimination in the spleen. We recently showed that a subpopulation of “small RBC” with reduced projected surface area accumulated upon storage in blood bank concentrates, but data on the volume of these altered RBC are lacking. So far, single cell measurement of RBC volume has remained a challenging task achieved by a few sophisticated methods some being subject to potential artifacts. We aimed to develop a reproducible and ergonomic method to assess simultaneously RBC volume and morphology at the single cell level. We adapted the fluorescence exclusion measurement of volume in nucleated cells to the measurement of RBC volume. This method requires no pre-treatment of the cell and can be performed in physiological or experimental buffer. In addition to RBC volume assessment, brightfield images enabling a precise definition of the morphology and the measurement of projected surface area can be generated simultaneously. We first verified that fluorescence exclusion is precise, reproducible and can quantify volume modifications following morphological changes induced by heating or incubation in non-physiological medium. We then used the method to characterize RBC stored for 42 days in SAG-M in blood bank conditions. Simultaneous determination of the volume, projected surface area and morphology allowed to evaluate the surface area-to-volume ratio of individual RBC upon storage. We observed a similar surface area-to-volume ratio in discocytes (D and echinocytes I (EI, which decreased in EII (7% and EIII (24%, sphero-echinocytes (SE; 41% and spherocytes (S; 47%. If RBC dimensions determine indeed the ability of RBC to cross the spleen, these modifications are expected to induce the rapid splenic entrapment of the most morphologically altered RBC

  9. Data on how several physiological parameters of stored red blood cells are similar in glucose 6-phosphate dehydrogenase deficient and sufficient donors

    Directory of Open Access Journals (Sweden)

    Vassilis L. Tzounakas

    2016-09-01

    Full Text Available This article contains data on the variation in several physiological parameters of red blood cells (RBCs donated by eligible glucose-6-phosphate dehydrogenase (G6PD deficient donors during storage in standard blood bank conditions compared to control, G6PD sufficient (G6PD+ cells. Intracellular reactive oxygen species (ROS generation, cell fragility and membrane exovesiculation were measured in RBCs throughout the storage period, with or without stimulation by oxidants, supplementation of N-acetylcysteine and energy depletion, following incubation of stored cells for 24 h at 37 °C. Apart from cell characteristics, the total or uric acid-dependent antioxidant capacity of the supernatant in addition to extracellular potassium concentration was determined in RBC units. Finally, procoagulant activity and protein carbonylation levels were measured in the microparticles population. Further information can be found in “Glucose 6-phosphate dehydrogenase deficient subjects may be better “storers” than donors of red blood cells” [1]. Keywords: G6PD deficiency, Red blood cell storage lesion, Oxidative stress, Cell fragility, Microparticles

  10. Marketing practices of vapor store owners.

    Science.gov (United States)

    Cheney, Marshall; Gowin, Mary; Wann, Taylor Franklin

    2015-06-01

    We examined the marketing strategies for local vapor stores in a large metropolitan area in Oklahoma. Vapor store owners or managers (n = 33) participated in individual interviews regarding marketing practices in 2014. We asked owners about their marketing strategies and the groups they targeted. We transcribed the interviews and analyzed them for themes. Store owners used a variety of marketing strategies to bring new customers to their stores and keep current customers coming back. These marketing strategies showed many parallels to tobacco industry strategies. Most owners engaged in some form of traditional marketing practices (e.g., print media), but only a few used radio or television advertising because of budget constraints. Owners used social media and other forms of electronic communication, pricing discounts and specials, and loyalty programs. Owners also had booths at local events, sponsored community events, and hosted them in their stores. Owners attempted to target different groups of users, such as college students and long-term smokers. Local vapor store marketing practices closely resemble current and former tobacco industry marketing strategies. Surveillance of marketing practices should include local and Web-based strategies.

  11. Marketing Practices of Vapor Store Owners

    Science.gov (United States)

    Gowin, Mary; Wann, Taylor Franklin

    2015-01-01

    Objectives. We examined the marketing strategies for local vapor stores in a large metropolitan area in Oklahoma. Methods. Vapor store owners or managers (n = 33) participated in individual interviews regarding marketing practices in 2014. We asked owners about their marketing strategies and the groups they targeted. We transcribed the interviews and analyzed them for themes. Results. Store owners used a variety of marketing strategies to bring new customers to their stores and keep current customers coming back. These marketing strategies showed many parallels to tobacco industry strategies. Most owners engaged in some form of traditional marketing practices (e.g., print media), but only a few used radio or television advertising because of budget constraints. Owners used social media and other forms of electronic communication, pricing discounts and specials, and loyalty programs. Owners also had booths at local events, sponsored community events, and hosted them in their stores. Owners attempted to target different groups of users, such as college students and long-term smokers. Conclusions. Local vapor store marketing practices closely resemble current and former tobacco industry marketing strategies. Surveillance of marketing practices should include local and Web-based strategies. PMID:25880960

  12. Storing red blood cells with vitamin C and N-acetylcysteine prevents oxidative stress-related lesions: a metabolomics overview.

    Science.gov (United States)

    Pallotta, Valeria; Gevi, Federica; D'alessandro, Angelo; Zolla, Lello

    2014-07-01

    Recent advances in red blood cell metabolomics have paved the way for further improvements of storage solutions. In the present study, we exploited a validated high performance liquid chromatography-mass spectrometry analytical workflow to determine the effects of vitamin C and N-acetylcysteine supplementation (anti-oxidants) on the metabolome of erythrocytes stored in citrate-phosphate-dextrose saline-adenine-glucose-mannitol medium under blood bank conditions. We observed decreased energy metabolism fluxes (glycolysis and pentose phosphate pathway). A tentative explanation of this phenomenon could be related to the observed depression of the uptake of glucose, since glucose and ascorbate are known to compete for the same transporter. Anti-oxidant supplementation was effective in modulating the redox poise, through the promotion of glutathione homeostasis, which resulted in decreased haemolysis and less accumulation of malondialdehyde and oxidation by-products (including oxidized glutathione and prostaglandins). Anti-oxidants improved storage quality by coping with oxidative stress at the expense of glycolytic metabolism, although reservoirs of high energy phosphate compounds were preserved by reduced cyclic AMP-mediated release of ATP.

  13. DNA quality and quantity from up to 16 years old post-mortem blood stored on FTA cards.

    Science.gov (United States)

    Rahikainen, Anna-Liina; Palo, Jukka U; de Leeuw, Wiljo; Budowle, Bruce; Sajantila, Antti

    2016-04-01

    Blood samples preserved on FTA cards offer unique opportunities for genetic research. DNA recovered from these cards should be stable for long periods of time. However, it is not well established as how well the DNA stored on FTA card for substantial time periods meets the demands of forensic or genomic DNA analyses and especially so for from post-mortem (PM) samples in which the quality can vary upon initial collection. The aim of this study was to evaluate the time-dependent degradation on DNA quality and quantity extracted from up to 16 years old post-mortem bloodstained FTA cards. Four random FTA samples from eight time points spanning 1998 to 2013 (n=32) were collected and extracted in triplicate. The quantity and quality of the extracted DNA samples were determined with Quantifiler(®) Human Plus (HP) Quantification kit. Internal sample and sample-to-sample variation were evaluated by comparing recovered DNA yields. The DNA from the triplicate samplings were subsequently combined and normalized for further analysis. The practical effect of degradation on DNA quality was evaluated from normalized samples both with forensic and pharmacogenetic target markers. Our results suggest that (1) a PM change, e.g. blood clotting prior to sampling, affects the recovered DNA yield, creating both internal and sample-to-sample variation; (2) a negative correlation between the FTA card storage time and DNA quantity (r=-0.836 at the 0.01 level) was observed; (3) a positive correlation (r=0.738 at the level 0.01) was found between FTA card storage time and degradation levels. However, no inhibition was observed with the method used. The effect of degradation was manifested clearly with functional applications. Although complete STR-profiles were obtained for all samples, there was evidence of degradation manifested as decreased peak heights in the larger-sized amplicons. Lower amplification success was notable with the large 5.1 kb CYP2D6 gene fragment which strongly supports

  14. Inductive energy store (IES) technology for multi-terrawatt generators

    International Nuclear Information System (INIS)

    Sincerny, P.S.; Ashby, S.R.; Childers, F.K.; Deeney, C.; Kortbawi, D.; Goyer, J.R.; Riordan, J.C.; Roth, I.S.; Stallings, C.; Schlitt, L.

    1993-01-01

    An IES pulsed power machine has been built at Physics International Company that serves as a prototype demonstration of IES technology that is scaleable to very large TW generators. The prototype module utilizes inductive store opening switch technology for the final stage of pulse compression and is capable of driving both electron beam Bremsstrahlung loads or imploding plasma loads. Each module consists of a fast discharge Marx driving a water dielectric transfer capacitor which is command triggered to drive the inductive store section of the machine. The inductive store is discharged into the load using a plasma erosion opening switch. Data demonstrating 22% efficient operation into an electron beam diode load are presented. The system issues addressing the combining of these modules into a very large pulsed power machine are discussed

  15. Retail marketing a in-store promotion společnosti Samsung Electronics Czech and Slovak s.r.o.

    OpenAIRE

    Košťál, Michal

    2015-01-01

    This thesis deals with the retail marketing and the in-store promotion. It is prima-rily focused on merchandising, sales promotion and other selected activities. The work itself is devoted to Samsung Electronics Czech and Slovak s.r.o. and is mostly based on a practical experience gained from a position of an employee. Firstly, the amount of investments in marketing of Samsung in comparison with the competition is introduced. The following part describes the basic retail acti-vities across th...

  16. Immunomodulating effect of blood transfusion: is storage time important?

    DEFF Research Database (Denmark)

    Mynster, T; Dybkjoer, E; Kronborg, Gitte

    1998-01-01

    in stimulating TNF-alpha and IL-2 release in an ex vivo assay. METHODS: Supernatants of 10 units of whole blood and 10 units of SAGM blood were collected after 1, 21 and 35 days of standard blood bank storage. Heparinized blood from 20 healthy volunteers (as 'recipients'), corresponding in ABO and Rh type......OBJECTIVES: TNF-alpha and IL-2 are important cytokines in macrophage and T-lymphocyte activity against infection and dissemination of malignant cells. We studied the influence of supernatants from stored whole blood and buffy-coat-depleted SAGM (saline, adenine, glucose and mannitol) blood...... to the stored blood, were used in a culture system with LPS and PHA as stimulators of TNF-alpha and IL-2 release. The effect of added supernatants, from either stored whole blood or SAGM blood, on cytokine release was evaluated compared to saline as control. TNF-alpha concentration was analyzed by ELISA after...

  17. Store manager performance and satisfaction: effects on store employee performance and satisfaction, store customer satisfaction, and store customer spending growth.

    Science.gov (United States)

    Netemeyer, Richard G; Maxham, James G; Lichtenstein, Donald R

    2010-05-01

    Based on emotional contagion theory and the value-profit chain literatures, the present study posits a number of hypotheses that show how managers in the small store, small number of employees retail context may affect store employees, customers, and potentially store performance. With data from 306 store managers, 1,615 store customer-contact employees, and 57,656 customers of a single retail chain, the authors examined relationships among store manager job satisfaction and job performance, store customer-contact employee job satisfaction and job performance, customer satisfaction with the retailer, and a customer-spending-based store performance metric (customer spending growth over a 2-year period). Via path analysis, several hypothesized direct and interaction relations among these constructs are supported. The results suggest implications for academic researchers and retail managers. PsycINFO Database Record (c) 2010 APA, all rights reserved.

  18. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  19. Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC for up to 7 days

    Directory of Open Access Journals (Sweden)

    Mahmoud Mohammed Sirdah

    2013-01-01

    Full Text Available BACKGROUND: The complete blood count is one of the most common routine tests. This study aimed to evaluate possible effects of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC over seven days. METHODS: Venous blood samples of 25 healthy males were distributed into two sets of tubes with each set of four tubes containing 50 µL of solutions with zero, 2.5 g/L, 5 g/L, 10 g/L taurine. The tubes were kept at room temperature or at 4ºC. Complete blood counts were performed on seven successive days. The mean percentage changes [Δ = (mean value - mean baseline value / mean baseline value x 100] were calculated and compared. RESULTS: Complete blood count parameters exhibited different patterns of behavior which were affected by the storage temperature, time and taurine concentration. Taurine at room temperature significantly enhancedthe stability of: the platelet count over seven days (Δ7 at 2.5, 5 and 10 g/L taurine were 5.45, 6.11, and 5.80 x 10(9 cells/L, respectively; the red blood cell count over five days (Δ5 at 2.5, 5 and 10 g/L taurine were 1.59, 2.79, and 1.98 x 10(12 cells/L, respectively; mean corpuscular hemoglobin over five days (Δ5 at 2.5, 5 and 10 g/L taurine were -0.91,-1.52 and -0.84 fl respectively; and red cell distribution width over two days (Δ2 at 2.5, 5 and 10 g/L taurine were 0.90%, 1.30% and -0.1%, respectively. No additional stabilizing effects of taurine were reported for the mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, hematocrit and hemoglobin, while it negatively affected the white blood cell stability. CONCLUSION: Complete blood count parameters exhibited variable stability patterns in respect to temperature, time and taurine concentration.

  20. Determination of proguanil and metabolites in small sample volumes of whole blood stored on filter paper by high-performance liquid chromatography.

    Science.gov (United States)

    Kolawole, J A; Taylor, R B; Moody, R R

    1995-12-01

    A method is reported for the determination of proguanil and its two metabolites cycloguanil and 4-chlorophenylbiguanide in whole blood and plasma samples obtained by thumbprick and stored dry on filter paper. The sample preparation involves liquid extraction from the filter paper and subsequent solid-phase extraction using C8 Bond-Elut cartridges. Separation and quantification is by a previously reported ion-pairing high-performance liquid chromatographic system with ODS Hypersil as stationary phase and an 50:50 acetonitrile-pH 2 phosphate buffer mobile phase containing 200 mM sodium dodecylsulphate as ion-pairing agent. The analytical characteristics of the method are reported. Representative concentrations are shown as a function of time from a human subject after ingestion of a single 200-mg dose of proguanil hydrochloride. Typical ranges of concentration detected by the proposed method in human subjects were proguanil 12-900 ng/ml, cycloguanil 16-44 ng/ml and 4-chlorophenylbiguanide 1.5-10 ng/ml in whole blood.

  1. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with an ... 0544 | Fax 202-776-0545 ASH Store ASH Job Center ASH Apps Share Your Idea Donate Research ...

  2. Electron arc therapy: Influence of heterogeneities on dose to blood-forming organs

    International Nuclear Information System (INIS)

    Leavitt, D.D.; Gibbs, F.A.; Moeller, J.H.

    1986-01-01

    Electron arc therapy has been used successfully to treat extended chest wall surfaces after mastectomy. Treatment is frequently given simultaneously with chemotherapy. Although the primary electron arc treatment volume consists only of the chest wall and mediastinum, dose is accumulated at the isocenter of rotation due to the photon contamination of the arcing electron beam. Additionally, higher energy electron fields which are occasionally used over segments of the arc may contribute to the dose at isocenter if the electron range has been extended due to passage through a low-density heterogeneity such as lung. In some patient setups, the isocenter may intersect blood-forming organs, such as the vertebral bodies. Thermoluminescent dosimetry has been used to measure the dose at isocenter for the following setups: polystyrene phantom, polystyrene phantom covered by 1-cm-thick lead cast, polystyrene phantom with cork insert to simulate lung, and phantom plus cork insert plus lead cast. For the 9-MeV treatment mode, dose at isocenter per 90 0 of arc (as a percentage of maximum tumor dose) is as follows: phantom, 6.5%; phantom plus lead, 5%; phantom plus cork, 8%; and phantom plus cork plus lead, 6%. These values must be scaled by the size of the arc to estimate dose at isocenter in actual treatments. Computer calculation showed good agreement with these measured values, indicating that the computerized treatment plans can be used as a predictor of electron arc dose to blood-forming organs

  3. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    Science.gov (United States)

    Metelkin, A.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.

    2015-11-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.

  4. Membrane materials for storing biological samples intended for comparative nanotoxicological testing

    International Nuclear Information System (INIS)

    Metelkin, A; Kuznetsov, D; Kolesnikov, E; Chuprunov, K; Kondakov, S; Osipov, A; Samsonova, J

    2015-01-01

    The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems. (paper)

  5. Na2EDTA anticoagulant impaired blood samples from the teleost Piaractus mesopotamicus

    Directory of Open Access Journals (Sweden)

    Thaís Heloisa Vaz Farias

    2016-05-01

    Full Text Available Abstract: The present study aimed to evaluate the effects of Na heparin and Na2EDTA on blood of Piaractus mesopotamicus (360.7±42.4g, 26.4±1.0cm. Twenty fishes were sampled in two experiment trials, ten for erythrocyte fragility analysis and ten for hematologic and plasma biochemical study. The blood collected by venous-caudal puncture was fractioned and stored in anticoagulants solution: Na2EDTA 10%, Na2EDTA 3%, Na heparin 5000 IU and Na heparin 100 IU. Plasmatic levels of calcium presented in the Na2EDTA stored samples were about 80% lower than both heparin groups. Blood samples of P. mesopotamicus stored with Na2EDTA demonstrated increase in the hematocrit and MCV, and decrease in MCHC. The dose-response effect was observed in this study. The results are reinforced by the higher levels of plasmatic protein and hemolysis presented in the Na2EDTA 10% stored blood, confirming the deleterious effect of this anticoagulant treatment on the quality of blood samples. Na2EDTA is not indicated to store P. mesopotamicus blood samples, but sodium heparin at 100 IU is the most recommended anticoagulant, since this treatment presented the lower rate of alterations in the stored blood.

  6. Flushable reagent stool blood test

    Science.gov (United States)

    Stool occult blood test - flushable home test; Fecal occult blood test - flushable home test ... This test is performed at home with disposable pads. You can buy the pads at the drug store without ...

  7. Imaging transient blood vessel fusion events in zebrafish by correlative volume electron microscopy.

    Directory of Open Access Journals (Sweden)

    Hannah E J Armer

    Full Text Available The study of biological processes has become increasingly reliant on obtaining high-resolution spatial and temporal data through imaging techniques. As researchers demand molecular resolution of cellular events in the context of whole organisms, correlation of non-invasive live-organism imaging with electron microscopy in complex three-dimensional samples becomes critical. The developing blood vessels of vertebrates form a highly complex network which cannot be imaged at high resolution using traditional methods. Here we show that the point of fusion between growing blood vessels of transgenic zebrafish, identified in live confocal microscopy, can subsequently be traced through the structure of the organism using Focused Ion Beam/Scanning Electron Microscopy (FIB/SEM and Serial Block Face/Scanning Electron Microscopy (SBF/SEM. The resulting data give unprecedented microanatomical detail of the zebrafish and, for the first time, allow visualization of the ultrastructure of a time-limited biological event within the context of a whole organism.

  8. Long-term stability of morphine, codeine, and 6-acetylmorphine in real-life whole blood samples, stored at -20°C.

    Science.gov (United States)

    Høiseth, Gudrun; Fjeld, Bente; Burns, Margrete Larsen; Strand, Dag Helge; Vindenes, Vigdis

    2014-06-01

    Stability of drugs during storage is important in forensic toxicology. For the analytes detected after intake of heroin (6-acetylmorphine (6-AM), morphine and codeine), long-time stability in real life whole blood samples are studied in only a small number of cases. Whole blood post mortem (n=37) and whole blood samples from living persons (n=22) containing morphine and codeine as well as 6-AM in blood or urine were selected. All cases represented intake of heroin. All samples contained fluoride and were initially analysed and stored in normal conditions (-20°C) for 4-9 years. All samples were then reanalysed using the same analytical methods and the results were compared. For samples from living persons, the median change in concentration was -3.7% for morphine and -5.3% for codeine. For post mortem samples, the median change in concentration was -12% for morphine and -11% for codeine. Both for samples from living persons and post mortem samples, the decrease in the concentrations from the original analysis to reanalysis were statistically significant for morphine and codeine. Regarding 6-AM, all living samples were negative at reanalysis. For post mortem samples, four cases still tested positive for 6-AM at reanalysis with a median change in the concentrations of -81%. There was no significant change in the morphine to codeine concentration ratios neither for living nor post mortem samples. This study showed that in real life whole blood samples, the concentrations of morphine and codeine are relatively stable during long-term storage at -20°C. 6-AM on the other hand, shows a considerable decrease in concentrations that is important to consider when interpreting results from reanalyses of forensic cases. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  9. Can latent heat safely warm blood? – in vitro testing of a portable prototype blood warmer

    OpenAIRE

    McEwen, Mark P; Roxby, David

    2007-01-01

    Abstract Background Trauma/retrieval patients are often in shock and hypothermic. Treatment of such patients usually involves restoring their blood volume with transfusion of blood (stored at 2°C – 6°C) and/or crystalloids or colloids (stored at ambient temperature). Rapid infusion of these cold fluids can worsen or even induce hypothermia in these patients. Warming of intravenous fluids at accident sites has traditionally been difficult due to a lack of suitable portable fluid warmers that a...

  10. Diagnostic potential of stored dried blood spots for inborn errors of metabolism: a metabolic autopsy of medium-chain acyl-CoA dehydrogenase deficiency.

    Science.gov (United States)

    Kaku, Noriyuki; Ihara, Kenji; Hirata, Yuichiro; Yamada, Kenji; Lee, Sooyoung; Kanemasa, Hikaru; Motomura, Yoshitomo; Baba, Haruhisa; Tanaka, Tamami; Sakai, Yasunari; Maehara, Yoshihiko; Ohga, Shouichi

    2018-05-02

    It is estimated that 1-5% of sudden infant death syndrome (SIDS) cases might be caused by undiagnosed inborn errors of metabolism (IEMs); however, the postmortem identification of IEMs remains difficult. This study aimed to evaluate the usefulness of dried blood spots (DBSs) stored after newborn screening tests as a metabolic autopsy to determine the causes of death in infants and children who died suddenly and unexpectedly. Infants or toddlers who had suddenly died without a definite diagnosis between July 2008 and December 2012 at Kyushu University Hospital in Japan were enrolled in this study. Their Guthrie cards, which had been stored for several years at 4-8°C, were used for an acylcarnitine analysis by tandem mass spectrometry to identify inborn errors of metabolism. Fifteen infants and children who died at less than 2 years of age and for whom the cause of death was unknown were enrolled for the study. After correcting the C0 and C8 values assuming the hydrolysation of acylcarnitine in the stored DBSs, the corrected C8 value of one case just exceeded the cut-off level for medium-chain acyl-CoA dehydrogenase (MCAD) deficiency screening. Genetic and biochemical analyses confirmed this patient to have MCAD deficiency. DBSs stored after newborn screening tests are a promising tool for metabolic autopsy. The appropriate compensation of acylcarnitine data and subsequent genetic and biochemical analyses are essential for the postmortem diagnosis of inborn errors of metabolism. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Specialty Store and Multi-Brand Store loyalty: An Indian consumer perspective

    Directory of Open Access Journals (Sweden)

    Sarabjot Singh

    2013-12-01

    Full Text Available In the competitive era of retailing, retailers need to understand the importance of store format preferences. The study aimed to understand consumer store loyalty; in-depth interview was conducted to examine consumer store loyalty antecedents for two retail formats: specialty stores and multi brand stores. The study conceptualizes store loyalty factors like program loyalty, trust and brand commitment. Trust and brand commitment act as mediating factors between store image and store loyalty formats, and also between brand image and store loyalty formats. The findings highlight how consumer store loyalty preference differ for these two formats.

  12. Net haemoglobin increase from reinfusion of refrigerated vs. frozen red blood cells after autologous blood transfusions

    DEFF Research Database (Denmark)

    Ashenden, M; Mørkeberg, Jakob Sehested

    2011-01-01

    BACKGROUND AND OBJECTIVES  Two main blood storage procedures can be used for storing red blood cells: refrigeration and freezing. Nevertheless, the efficiency of these procedures measured as the increase in haemoglobin after reinfusion compared with baseline has never been examined. The main...... objective was to examine which storage procedure yielded the largest increase in circulating haemoglobin after reinfusion compared to baseline. MATERIALS AND METHODS  Equal volumes of blood from 15 men were withdrawn and stored either frozen or refrigerated as packed red blood cells. Serial measures...... of circulating haemoglobin by carbon monoxide rebreathing provided an opportunity to monitor recovery from anaemia, as well as the net increase in circulating haemoglobin after transfusion. RESULTS  The post-thaw yield of haemoglobin in the bags was 72% after refrigerated storage compared with only 52% after...

  13. Electron cloud buildup driving spontaneous vertical instabilities of stored beams in the Large Hadron Collider

    Directory of Open Access Journals (Sweden)

    Annalisa Romano

    2018-06-01

    Full Text Available At the beginning of the 2016 run, an anomalous beam instability was systematically observed at the CERN Large Hadron Collider (LHC. Its main characteristic was that it spontaneously appeared after beams had been stored for several hours in collision at 6.5 TeV to provide data for the experiments, despite large chromaticity values and high strength of the Landau-damping octupole magnet. The instability exhibited several features characteristic of those induced by the electron cloud (EC. Indeed, when LHC operates with 25 ns bunch spacing, an EC builds up in a large fraction of the beam chambers, as revealed by several independent indicators. Numerical simulations have been carried out in order to investigate the role of the EC in the observed instabilities. It has been found that the beam intensity decay is unfavorable for the beam stability when LHC operates in a strong EC regime.

  14. Survival of the fittest?--survival of stored red blood cells after transfusion.

    NARCIS (Netherlands)

    Luten, M.; Roerdinkholder-Stoelwinder, B.; Bost, H.J.; Bosman, G.J.C.G.M.

    2004-01-01

    During the last 90 years many developments have taken place in the world of blood transfusion. Several anticoagulants and storage solutions have been developed. Also the blood processing has undergone many changes. At the moment, in The Netherlands, red blood cell (RBC) concentrates (prepared from a

  15. Localization of tritiated vitamin A in lymph nodes of the mouse: an autoradiographic study of vitamin A-storing cells

    International Nuclear Information System (INIS)

    Hirosawa, K.; Yamada, E.

    1981-01-01

    Localization of tritiated vitamin A in lymph nodes of the mouse was investigated by the use of light- and electron-microscopic autoradiography. Young male mice were fed a diet containing 3H-vitamin A acetate for a week. Lymph nodes were removed and prepared for autoradiography. Lipid droplets in fibroblast-like cells showed high concentrations of radioactivity. These cells were distributed around lymphatic sinuses and blood vessels. The cells can, therefore, be classified as ''vitamin A-storing cells'' according to criteria proposed earlier by Yamada and Hirosawa (1976). Control animals from the same litter were maintained on ordinary laboratory food for the same period and examined by electron microscopy. Lipid-droplet-containing cells were found in the same areas as in the experimental animals but in fewer numbers. This suggests that the increased number of vitamin A-containing lipid droplets is due to hypervitaminosis A in the experimental animals. The presence of some cells containing these droplets in the control animals would imply that even under normal feeding conditions the animals ingested excess amounts of vitamin A, which was retained in lipid droplets. The stored vitamin A probably participates in metabolic processes such as the formation of glycoproteins in ground substance

  16. Beam electron microprobe

    CERN Document Server

    Stoller, D; Muterspaugh, M W; Pollock, R E

    1999-01-01

    A beam profile monitor based on the deflection of a probe electron beam by the electric field of a stored, electron-cooled proton beam is described and first results are presented. Electrons were transported parallel to the proton beam by a uniform longitudinal magnetic field. The probe beam may be slowly scanned across the stored beam to determine its intensity, position, and size. Alternatively, it may be scanned rapidly over a narrow range within the interior of the stored beam for continuous observation of the changing central density during cooling. Examples of a two dimensional charge density profile obtained from a raster scan and of a cooling alignment study illustrate the scope of measurements made possible by this device.

  17. The Changing Face of the College Store

    Science.gov (United States)

    Halligan, Tom

    2008-01-01

    Increased competition from Internet merchants, coupled with the swelling popularity of electronic books and skyrocketing textbook prices, is forcing the nation's college stores to get creative, find new ways to boost revenues, and drive sales of books and other merchandise to students and faculty. To make up for lost revenue as a result of…

  18. STORE IN STORE FRANCHISING STRATEGY: THE TREND IN FRANCHISING NEGOTIATION

    OpenAIRE

    Rosado-Serrano, Alexander; Universidad de Puerto Rico

    2016-01-01

    The literature on franchising has traditionally focused on the effects and transformation it has promoted in the service sector, retailing, restaurants, hotels and other service-related industries. Store within a store research has been focused on the perspective of the manufacturer entering department stores. To date, little research has been carried out for the store in store strategy from the franchising perspective. This paper explores why big box retailers such as Walmart are adopting th...

  19. Extending The Shelf Life Of Blood Platelets

    Science.gov (United States)

    Surgenor, Douglas M.

    1988-01-01

    New method of storing human blood platelets extends vitality for transfusions. Packaged as suspension in sterile liquid in plastic blood bags. Each bag placed between pair of plastic grids, and rubberbands placed around sandwich thus formed to hold together. Stored upright in open air or in container through which air pumped at rate of at least 45 L/min. Ensures that platelets receive ample oxygen and expiratory carbon dioxide form platelets removed before pH drops to harmful levels.

  20. Prolonged storage of packed red blood cells for blood transfusion.

    Science.gov (United States)

    Martí-Carvajal, Arturo J; Simancas-Racines, Daniel; Peña-González, Barbra S

    2015-07-14

    A blood transfusion is an acute intervention, used to address life- and health-threatening conditions on a short-term basis. Packed red blood cells are most often used for blood transfusion. Sometimes blood is transfused after prolonged storage but there is continuing debate as to whether transfusion of 'older' blood is as beneficial as transfusion of 'fresher' blood. To assess the clinical benefits and harms of prolonged storage of packed red blood cells, in comparison with fresh, on recipients of blood transfusion. We ran the search on 1st May 2014. We searched the Cochrane Injuries Group Specialized Register, Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), MEDLINE (OvidSP), Embase (OvidSP), CINAHL (EBSCO Host) and two other databases. We also searched clinical trials registers and screened reference lists of the retrieved publications and reviews. We updated this search in June 2015 but these results have not yet been incorporated. Randomised clinical trials including participants assessed as requiring red blood cell transfusion were eligible for inclusion. Prolonged storage was defined as red blood cells stored for ≥ 21 days in a blood bank. We did not apply limits regarding the duration of follow-up, or country where the study took place. We excluded trials where patients received a combination of short- and long-stored blood products, and also trials without a clear definition of prolonged storage. We independently performed study selection, risk of bias assessment and data extraction by at least two review authors. The major outcomes were death from any cause, transfusion-related acute lung injury, and adverse events. We estimated relative risk for dichotomous outcomes. We measured statistical heterogeneity using I(2). We used a random-effects model to synthesise the findings. We identified three randomised clinical trials, involving a total of 120 participants, comparing packed red blood cells with ≥ 21 days storage

  1. Polarizing a stored proton beam by spin-flip?

    International Nuclear Information System (INIS)

    Oellers, Dieter Gerd Christian

    2010-01-01

    The present thesis discusses the extraction of the electron-proton spin-flip cross-section. The experimental setup, the data analysis and the results are pictured in detail. The proton is described by a QCD-based parton model. In leading twist three functions are needed. The quark distribution, the helicity distribution and the transversity distribution. While the first two are well-known, the transversity distribution is largely unknown. A self-sufficient measurement of the transversity is possible in double polarized proton-antiproton scattering. This rises the need of a polarized antiproton beam. So far spin filtering is the only tested method to produce a polarized proton beam, which may be capable to hold also for antiprotons. In-situ polarization build-up of a stored beam either by selective removal or by spin-flip of a spin-(1)/(2) beam is mathematically described. A high spin-flip cross-section would create an effective method to produce a polarized antiproton beam by polarized positrons. Prompted by conflicting calculations, a measurement of the spin-flip cross-section in low-energy electron-proton scattering was carried out. This experiment uses the electron beam of the electron cooler at COSY as an electron target. The depolarization of the stored proton beam is detected. An overview of the experiment is followed by detailed descriptions of the cycle setup, of the electron target and the ANKE silicon tracking telescopes acting as a beam polarimeter. Elastic protondeuteron scattering is the analyzing reaction. The event selection is depicted and the beam polarization is calculated. Upper limits of the two electron-proton spin-flip cross-sections σ parallel and σ perpendicular to are deduced using the likelihood method. (orig.)

  2. Removal of stored particle background via the electric dipole method in the KATRIN main spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hilk, Daniel [Institut fuer Experimentelle Kernphysik, KIT, Karlsruhe (Germany); Collaboration: KATRIN-Collaboration

    2016-07-01

    The goal of the KArlsruhe TRItium Neutrino (KATRIN) experiment is to determine the effective mass of the electron anti neutrino by measuring the electron energy spectrum of tritium beta decay near the endpoint. The goal is to reach a sensitivity on the neutrino mass of 200 meV for which a low background level of 10{sup -2} counts per second is mandatory. Electrons from single radioactive decays of radon and tritium in the KATRIN main spectrometer with energies in the keV range can be magnetically stored for hours. While cooling down via ionization of residual gas molecules, they produce hundreds of secondary electrons, which can reach the detector and contribute to the background signals. In order to suppress this background component, several methods are investigated to remove stored electrons, such as the application of an electric dipole field and the application of magnetic pulses. This talk introduces the mechanism of background production due to stored electrons and their removal by the electric dipole method in the main spectrometer. In context of the spectrometer- and detector-commissioning phase in summer 2015, measurement results of the application of the electric dipole method are presented.

  3. Store tobacco policies: a survey of store managers, California, 1996-1997.

    Science.gov (United States)

    Weinbaum, Z; Quinn, V; Rogers, T; Roeseler, A

    1999-01-01

    To identify store tobacco policies and retailer perception and beliefs that may have contributed to changes in compliance with youth access laws in California. In the winter of 1996-7, a cross sectional, follow up telephone survey was conducted of California store managers whose stores were anonymously surveyed for illegal tobacco sales in the summer of 1996 (that is, 1996 Youth Tobacco Purchase Survey, YTPS). A simple random sample of stores from a list of California stores likely to sell tobacco, used in the 1996 YTPS. 334 managers (77%) of the 434 stores surveyed in 1996 responded to the survey. After eliminating stores that stopped selling tobacco or were under new management or ownership, 320 responses of store managers were included in the analysis. The stores were analysed by type of ownership: chain, which included corporate managed (n = 61); franchise owned (n = 56); and independent (n = 203). Responses of store managers were linked with the 1996 YTPS outcomes. Manager responses were compared by chi2 tests. Logistic regression analyses were conducted to identify store factors associated with illegal tobacco sales. A lower likelihood of illegal sales rate was associated with the chain stores when compared with the independent stores (odds ratio (OR) = 0.4, 95% confidence interval (CI) 0.2 to 0.9). A lower likelihood of illegal tobacco sales was found in stores that implemented tobacco related activities in the previous year such as changing tobacco displays (OR = 0.5, 95% CI 0.2 to 0.9) or adding new warning signs (OR = 0.7, 95% CI 0.4 to 1.2). Store managers' beliefs that youth were sent to their stores to do compliance checks also resulted in a lower likelihood of illegal sales (OR = 0.7, 95% CI 0.4 to 1.1). Store tobacco youth access policies, and managers' beliefs about the extent of youth access enforcement in the community, are important in reducing illegal tobacco sales to minors.

  4. Store and forward teledermatology

    Directory of Open Access Journals (Sweden)

    Kanthraj Garehatty

    2007-01-01

    Full Text Available Store and forward and real time or videoconferences are the two types of teledermatology services practiced. Dermatology and radio-diagnosis are visual specialties suited for store-and-forward teledermatology (SAFT. Advances in information technology, electronic instruments and biotechnology have revolutionized and brought changes in SAFT. Cellular phone, digital camera, personal digital assistants, Wi-Fi, Wi-Max and computer- aided-design software are incorporated to deliver the quality health care to remote geographic regions. Complete SAFT care equivalent to face-to-face consultation (Gold standard is essential. Health care providers in rural areas are the ′eyes′ for the consultants. Consultants to guide them should have a rapid periodic audit of visual parameters and dimensions of lesions. Given this background, this article reviews advances in 1 capture, store and transfer of images. 2 Computer Aided measurements of generalized and localized lesions and 3 the integration model to meet all the above two requirements in a centralized location. This process enables diagnosis, management, periodic assessment and complete follow-up care to achieve patient and physician satisfaction. Preservation of privacy and confidentiality of digital images is important. Uniform rules and regulations are required. Indian space research organization (ISRO, Government of India has demonstrated telemedicine pilot projects utilizing the satellite communication and mobile telemedicine units to be useful in meeting the health care needs of remote and rural India. we have to join hands with them to meet dermatology problems in rural areas.

  5. Reproducibility of Serum Potassium Values in Serum From Blood Samples Stored for Increasing Times Prior to Centrifugation and Analysis.

    Science.gov (United States)

    Harper, Aaron; Lu, Chuanyong; Sun, Yi; Garcia, Rafael; Rets, Anton; Alexis, Herol; Saad, Heba; Eid, Ikram; Harris, Loretta; Marshall, Barbara; Tafani, Edlira; Pincus, Matthew R

    2016-05-01

    The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values. © 2015 Wiley Periodicals, Inc.

  6. Sodium in Store and Restaurant Food Environments - Guam, 2015.

    Science.gov (United States)

    Jackson, Sandra L; VanFrank, Brenna K; Lundeen, Elizabeth; Uncangco, Alyssa; Alam, Lawrence; King, Sallyann M Coleman; Cogswell, Mary E

    2016-05-27

    Compared with the United States overall, Guam has higher mortality rates from cardiovascular disease and stroke (1). Excess sodium intake can increase blood pressure and risk for cardiovascular disease (2,3). To determine the availability and promotion of lower-sodium options in the nutrition environment, the Guam Department of Public Health and Social Services (DPHSS) conducted an assessment in September 2015 using previously validated tools adapted to include sodium measures. Stores (N = 114) and restaurants (N = 63) were randomly sampled by region (north, central, and south). Data from 100 stores and 62 restaurants were analyzed and weighted to account for the sampling design. Across the nine product types assessed, lower-sodium products were offered less frequently than regular-sodium products (prestaurants engaged in promotion practices such as posting sodium information (3%) or identifying lower-sodium entrées (1%). Improving the availability and promotion of lower-sodium foods in stores and restaurants could help support healthier eating in Guam.

  7. Establishing an online store in the furniture retail business : Case study of Lähdesmäki Oy

    OpenAIRE

    Kareno, Justus

    2013-01-01

    This thesis describes the process of establishing an online store for a Finnish furniture retailer. The development of electronic commerce as a means of business is introduced as the force driving furniture retailers to establish an online presence. The theory of electronic commerce is presented and analyzed in terms of differences compared to sales via a conventional store. The development of electronic furniture retailing is analyzed by researching furniture retailers in Finland and th...

  8. Quality Assessment of Platelet-Rich Fibrin-Like Matrix Prepared from Whole Blood Samples after Extended Storage

    Directory of Open Access Journals (Sweden)

    Hideo Kawabata

    2017-09-01

    Full Text Available The platelet-rich fibrin–like matrix (PRFM is usually prepared onsite and immediately used for regenerative therapy. Nonetheless, to meet the clinical necessity of preserving the PRFM without quality deterioration, we developed a method for preparation of PRFMs from short-term-stored whole blood (WB samples. In this study, to evaluate the practical expiration date of storage, we extended the storage time of WB samples from 2 to 7 days and assessed the quality of the resulting PRFMs. WB samples collected with acid-citrate-dextrose were stored with gentle agitation at ambient temperature. To prepare PRFMs, the stored WB samples were mixed with CaCl2 in glass tubes and centrifuged. Fibrin fiber networks, CD41 and CD62P expression, and Platelet Derived Growth Factor-BB (PDGF-BB levels were examined by scanning electron microscopy (SEM, flow cytometry, and an Enzyme-Linked ImmunoSorbent Assay (ELISA, respectively. Long-term storage had no significant effect on either blood cell counts or platelet functions tested. The resulting PRFMs were visually identical to freshly prepared ones. PDGF-BB levels did not markedly decrease in a time-dependent manner. However, fibrin fibers gradually became thinner after storage. Although the coagulation activity may diminish, we propose that PRFMs can be prepared—without evident loss of quality—from WB samples stored for up to 7 days by our previously developed method.

  9. Electron transfer from H2 and Ar to stored multiply charged argon ions produced by synchrotron radiation

    International Nuclear Information System (INIS)

    Kravis, S.D.; Church, D.A.; Johnson, B.M.; Meron, M.; Jones, K.W.; Levin, J.C.; Sellin, I.A.; Azuma, Y.; Berrah-Mansour, N.; Berry, H.G.; Druetta, M.

    1992-01-01

    The rate coefficients for electron transfer from Ar and H 2 to Ar q+ ions (3≤q≤6) have been measured using an ion-storage technique in a Penning ion trap. The ions were produced in the trap by K-shell photoionization of Ar atoms, using broadband synchrotron x-ray radiation. K-electron removal resulted in vacancy cascading, yielding a distribution of argon-ion charge states peaked near Ar 4+ . The stored ion gas had an initial temperature near 480 K. The basic data determining the rate coefficients k(Ar q+ ) are the storage time constants of each charge state in the trap, in the presence of a measured pressure of target gas. The results of the measurements (in units of 10 -9 cm 3 s -1 ) are k(Ar 3+ ,H 2 )=4.3(0.7), k(Ar 3+ ,Ar)=1.6(0.2), k(Ar 4+ ,H 2 )=5.2(0.6), k(Ar 4+ ,Ar)=2.5(0.3), k(Ar 5+ ,H 2 )=5.9(0.7), k(Ar 5+ ,Ar)=2.9(0.3), k(Ar 6+ ,H 2 )=8.5(1.2), and k(Ar 6+ ,Ar)=2.5(0.3)

  10. Organizational choices and financial performance: the case of company-owned stores, franchisee-owned stores and stores-within-a-store among French fashion retailers

    OpenAIRE

    Paul Amadieu; Karine Picot-Coupey; Jean-Laurent Viviani

    2013-01-01

    This paper deals with the governance and financial performance issues in the context of French Fashion retail companies. In this study, we analyze the influence of the organizational choices on the financial performance at the network level. We consider three forms used in isolation (company-owned stores, franchisee-owned stores and stores-within-a-store), three dually-organized forms (dual forms mixing two of the three forms) as well as a combined form associating the three ones. We study a ...

  11. Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results.

    Science.gov (United States)

    Iwersen, M; Klein-Jöbstl, D; Pichler, M; Roland, L; Fidlschuster, B; Schwendenwein, I; Drillich, M

    2013-01-01

    The objective of this study was to determine the suitability of 2 electronic hand-held devices [FreeStyle Precision (FSP), Abbott GmbH & Co. KG, Wiesbaden, Germany and GlucoMen LX Plus (GLX), A. Menarini GmbH, Vienna, Austria] for measuring β-hydroxybutyrate (BHBA) in dairy cows. Three experiments were conducted to evaluate (1) the diagnostic performance of the devices, (2) the effect of the type of blood sample, and (3) the influence of the ambient temperature on the determined results. A total of 415 blood samples from lactating Holstein and Simmental cows were collected and analyzed with both devices (whole blood) and in a laboratory (serum). Correlation coefficients between whole-blood and serum BHBA concentrations were highly significant, with 94% for the FSP and 80% for the GLX device. Based on thresholds for subclinical ketosis of 1.2 and 1.4 mmol of BHBA/L, results obtained with the hand-held devices were evaluated by receiver operating characteristics analyses. This resulted in adjusted thresholds of 1.2 and 1.4 mmol/L for the FSP and 1.1 and 1.3 mmol/L for the GLX device. Applying these thresholds, sensitivities were 98 and 100% for the FSP and 80 and 86% for the GLX device, respectively. Corresponding specificities were 90 and 97% for the FSP and 87 and 96% for the GLX device, respectively. Additionally, concentrations of BHBA were tested with both devices in whole blood, EDTA-added whole blood, and in their resulting serum and plasma, collected from 65 animals. Determined BHBA concentrations were similar within each device for whole and EDTA-added blood, and in serum and plasma, but differed between whole blood and serum and between EDTA-added blood and plasma. Blood samples with low (0.4 mmol/L), medium (1.1 mmol/L), and high (1.6 mmol/L) BHBA concentrations were stored between +5 to +32°C and analyzed repeatedly at temperature levels differing by 4°C. Additionally, devices and test strips were stored at equal conditions and used for measurement

  12. Reduction in unnecessary red blood cell folate testing by restricting computerized physician order entry in the electronic health record.

    Science.gov (United States)

    MacMillan, Thomas E; Gudgeon, Patrick; Yip, Paul M; Cavalcanti, Rodrigo B

    2018-05-02

    Red blood cell folate is a laboratory test with limited clinical utility. Previous attempts to reduce physician ordering of unnecessary laboratory tests, including folate, have resulted in only modest success. The objective of this study was to assess the effectiveness and impacts of restricting red blood cell folate ordering in the electronic health record. This was a retrospective observational study from January 2010 to December 2016 at a large academic healthcare network in Toronto, Canada. All inpatients and outpatients who underwent at least 1 red blood cell folate or vitamin B12 test during the study period were included. Red blood cell folate ordering was restricted to clincians in gastroenterology and hematology and was removed from other physicians' computerized order entry screen in the electronic health record in June 2013. Red blood cell folate testing decreased by 94.4% during the study, from a mean of 493.0 (SD 48.0) tests/month before intervention to 27.6 (SD 10.3) tests/month after intervention (P<.001). Restricting red blood cell folate ordering in the electronic health record resulted in a large and sustained reduction in red blood cell folate testing. Significant cost savings estimated at over a quarter-million dollars (CAD) over three years were achieved. There was no significant clinical impact of the intervention on the diagnosis of folate deficiency. Copyright © 2018. Published by Elsevier Inc.

  13. TO STORES USERS

    CERN Multimedia

    SPL Division

    2001-01-01

    Stores users are informed that the Stores (Central, Emergency window, Raw materials, Chemical products and Prévessin Self service stores) will be closed on Friday, 7 December owing to migration of the Stores computers to Windows 2000. Thank you for your understanding.

  14. The volume-expanding effects of autologous liquid stored plasma following hemorrhage

    DEFF Research Database (Denmark)

    Bentzer, Peter; Thomas, Owain D; Westborg, Johan

    2012-01-01

    of plasma transfusion on plasma volume. We report a prospective interventional study in which the plasma volume-expanding effect of autologous plasma was investigated after a controlled hemorrhage. Methods. Plasma obtained by plasmapheresis from nine healthy regular blood donors was stored at 2-6°C. Five...

  15. Long-Term Stored Hemoglobin-Vesicles, a Cellular Type of Hemoglobin-Based Oxygen Carrier, Has Resuscitative Effects Comparable to That for Fresh Red Blood Cells in a Rat Model with Massive Hemorrhage without Post-Transfusion Lung Injury.

    Directory of Open Access Journals (Sweden)

    Masahiro Tokuno

    Full Text Available Hemoglobin-vesicles (HbV, encapsulating highly concentrated human hemoglobin in liposomes, were developed as a substitute for red blood cells (RBC and their safety and efficacy in transfusion therapy has been confirmed in previous studies. Although HbV suspensions are structurally and physicochemically stabile for least 1-year at room temperature, based on in vitro experiments, the issue of whether the use of long-term stored HbV after a massive hemorrhage can be effective in resuscitations without adverse, post-transfusion effects remains to be clarified. We report herein on a comparison of the systemic response and the induction of organ injuries in hemorrhagic shock model rats resuscitated using 1-year-stored HbV, freshly packed RBC (PRBC-0 and by 28-day-stored packed RBC (PRBC-28. The six-hour mortality after resuscitation was not significantly different among the groups. Arterial blood pressure and blood gas parameters revealed that, using HbV, recovery from the shock state was comparable to that when PRBC-0 was used. Although no significant change was observed in serum parameters reflecting liver and kidney injuries at 6 hours after resuscitation among the three resuscitation groups, results based on Evans Blue and protein leakage in bronchoalveolar lavage fluid, the lung wet/dry weight ratio and histopathological findings indicated that HbV as well as PRBC-0 was less predisposed to result in a post-transfusion lung injury than PRBC-28, as evidenced by low levels of myeloperoxidase accumulation and subsequent oxidative damage in the lung. The findings reported herein indicate that 1-year-stored HbV can effectively function as a resuscitative fluid without the induction of post-transfused lung injury and that it is comparable to fresh PRBC, suggesting that HbV is a promising RBC substitute with a long shelf-life.

  16. Can routine commercial cord blood banking be scientifically and ethically justified?

    Directory of Open Access Journals (Sweden)

    Nicholas M Fisk

    2005-02-01

    Full Text Available BACKGROUND TO THE DEBATE: Umbilical cord blood--the blood that remains in the placenta after birth--can be collected and stored frozen for years. A well-accepted use of cord blood is as an alternative to bone marrow as a source of hematopoietic stem cells for allogeneic transplantation to siblings or to unrelated recipients; women can donate cord blood for unrelated recipients to public banks. However, private banks are now open that offer expectant parents the option to pay a fee for the chance to store cord blood for possible future use by that same child (autologous transplantation.

  17. Quality assessment of buccal versus blood genomic DNA using the Affymetrix 500 K GeneChip

    Directory of Open Access Journals (Sweden)

    Martin Lisa J

    2007-11-01

    Full Text Available Abstract Background With the advent of genome-wide genotyping, the utility of stored buccal brushes for DNA extraction and genotyping has been questioned. We sought to describe the genomic DNA yield and concordance between stored buccal brushes and blood samples from the same individuals in the context of Affymetrix 500 K Human GeneChip genotyping. Results Buccal cytobrushes stored for ~7 years at -80°C prior to extraction yielded sufficient double stranded DNA (dsDNA to be successfully genotyped on the Affymetrix ~262 K NspI chip, with yields between 536 and 1047 ng dsDNA. Using the BRLMM algorithm, genotyping call rates for blood samples averaged 98.4%, and for buccal samples averaged 97.8%. Matched blood samples exhibited 99.2% concordance, while matched blood and buccal samples exhibited 98.8% concordance. Conclusion Buccal cytobrushes stored long-term result in sufficient dsDNA concentrations to achieve high genotyping call rates and concordance with stored blood samples in the context of Affymetrix 500 K SNP genotyping. Thus, given high-quality collection and storage protocols, it is possible to use stored buccal cytobrush samples for genome-wide association studies.

  18. Polarizing a stored proton beam by spin-flip?

    Energy Technology Data Exchange (ETDEWEB)

    Oellers, Dieter Gerd Christian

    2010-04-15

    The present thesis discusses the extraction of the electron-proton spin-flip cross-section. The experimental setup, the data analysis and the results are pictured in detail. The proton is described by a QCD-based parton model. In leading twist three functions are needed. The quark distribution, the helicity distribution and the transversity distribution. While the first two are well-known, the transversity distribution is largely unknown. A self-sufficient measurement of the transversity is possible in double polarized proton-antiproton scattering. This rises the need of a polarized antiproton beam. So far spin filtering is the only tested method to produce a polarized proton beam, which may be capable to hold also for antiprotons. In-situ polarization build-up of a stored beam either by selective removal or by spin-flip of a spin-(1)/(2) beam is mathematically described. A high spin-flip cross-section would create an effective method to produce a polarized antiproton beam by polarized positrons. Prompted by conflicting calculations, a measurement of the spin-flip cross-section in low-energy electron-proton scattering was carried out. This experiment uses the electron beam of the electron cooler at COSY as an electron target. The depolarization of the stored proton beam is detected. An overview of the experiment is followed by detailed descriptions of the cycle setup, of the electron target and the ANKE silicon tracking telescopes acting as a beam polarimeter. Elastic protondeuteron scattering is the analyzing reaction. The event selection is depicted and the beam polarization is calculated. Upper limits of the two electron-proton spin-flip cross-sections {sigma} {sub parallel} and {sigma} {sub perpendicular} {sub to} are deduced using the likelihood method. (orig.)

  19. Virtual and game-inspired approaches to concept store planning

    DEFF Research Database (Denmark)

    Andreasen, Kristian Emil; Tambo, Torben

    2012-01-01

    will typically involve engagement from franchisers, landlord, chain management, visual merchandisers, architects and construction specialists. In this paper a system is presented and discussed for electronic modeling of concept store. The system is based on principles of computer games, gamification, to let...

  20. New results with stored exotic nuclei at relativistic energies

    Energy Technology Data Exchange (ETDEWEB)

    Bosch, F. (Fritz); Boutin, D. (Daniel); Fastermann, T. (Thomas); Falch, M. (Markus); Franzke, B. (Bernhard); Hausmann, M. (Marc); Hellstrom, M. (Margarete); Kaza, E. (Evangelia); Kerscher, T. (Thomas); Klepper, O. (Otto); Kluge, H.-Jürgen; Kozhuharov, C. (Christophor); Kratz, K. L.; Litinov, S. A. (Sergei A); Lobner, G. K. E. (Gunther K. E.); Maier, L. (Ludwig); Matos, M. (Milan); Munzenberg, G. (Gottfried); Nolden, F. (Fritz); Novikov, Y. N. (Yuri N.); Ohtsubo, T. (Takashi); Ostrowski, A. (Alexander); Patyk, Z. (Zygmund); Pfeiffer, B.; Portillo, M. (Mauricio); Radon, T. P. (Torsten P.); Scheidenberger, C. (Christoph); Shishkin, V. (Vladimir); Stadlman, J. (Jens); Steck, M. (Markus); Vieira, D. J. (David J.); Weick, H. (Helmut); Winkler, M. (Martin); Wollnik, Hermann; Yamaguchi, T. (Takayuki)

    2004-01-01

    Recently, much progress has been made with stored exotic nuclei at relativistic velocities v/c = 0.7. Fragments of {sup 208}Pb and {sup 209}Bi projectiles and fission fragments from {sup 238}U ions have been produced, separated in flight with the fragment separator FRS, and injected into the storage-cooler ring ESR for precision measurements. Precise masses of neutron-deficient isotopes in the lead region have been measured with time-resolved Schottky Mass Spectrometry (SMS). A new isospin dependence of the pairing energy was observed due to the improved mass accuracy of typical 1.5 x 10{sup -7} (30 keV). New masses of short-lived neutron-rich fission fragments have been obtained with Isochronous Mass Spectrometry (IMS). An innovative field of spectroscopy has been opened up with lifetime measurements of stored bare and few-electron fragments after applying both stochastic and electron cooling.

  1. The effect of frequent whole blood donation on ferritin, hepcidin, and subclinical atherosclerosis

    NARCIS (Netherlands)

    Peffer, K.; Heijer, M. den; Holewijn, S.; Graaf, J. de; Swinkels, D.W.; Verbeek, A.L.M.; Atsma, F.

    2013-01-01

    BACKGROUND: Iron catalyzes the formation of free radicals, which could lead to damaged vascular walls and subsequent atherosclerosis. Blood donation decreases iron stores and can thus decrease cardiovascular risk. Even within blood donors, differences in stored iron are observed. This study

  2. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Store ASH Job Center ASH Apps Share Your Idea Donate My Account ... Edition Abstracts Blood Advances A peer-reviewed journal with a unique focus on scholarly and educational ...

  3. A cell transportation solution that preserves live circulating tumor cells in patient blood samples

    International Nuclear Information System (INIS)

    Stefansson, Steingrimur; Adams, Daniel L.; Ershler, William B.; Le, Huyen; Ho, David H.

    2016-01-01

    Circulating tumor cells (CTCs) are typically collected into CellSave fixative tubes, which kills the cells, but preserves their morphology. Currently, the clinical utility of CTCs is mostly limited to their enumeration. More detailed investigation of CTC biology can be performed on live cells, but obtaining live CTCs is technically challenging, requiring blood collection into biocompatible solutions and rapid isolation which limits transportation options. To overcome the instability of CTCs, we formulated a sugar based cell transportation solution (SBTS) that stabilizes cell viability at ambient temperature. In this study we examined the long term viability of human cancer cell lines, primary cells and CTCs in human blood samples in the SBTS for transportation purposes. Four cell lines, 5 primary human cells and purified human PBMCs were tested to determine the viability of cells stored in the transportation solution at ambient temperature for up to 7 days. We then demonstrated viability of MCF-7 cells spiked into normal blood with SBTS and stored for up to 7 days. A pilot study was then run on blood samples from 3 patients with metastatic malignancies stored with or without SBTS for 6 days. CTCs were then purified by Ficoll separation/microfilter isolation and identified using CTC markers. Cell viability was assessed using trypan blue or CellTracker™ live cell stain. Our results suggest that primary/immortalized cell lines stored in SBTS remain ~90 % viable for > 72 h. Further, MCF-7 cells spiked into whole blood remain viable when stored with SBTS for up to 7 days. Finally, live CTCs were isolated from cancer patient blood samples kept in SBTS at ambient temperature for 6 days. No CTCs were isolated from blood samples stored without SBTS. In this proof of principle pilot study we show that viability of cell lines is preserved for days using SBTS. Further, this solution can be used to store patient derived blood samples for eventual isolation of viable CTCs

  4. A cell transportation solution that preserves live circulating tumor cells in patient blood samples.

    Science.gov (United States)

    Stefansson, Steingrimur; Adams, Daniel L; Ershler, William B; Le, Huyen; Ho, David H

    2016-05-06

    Circulating tumor cells (CTCs) are typically collected into CellSave fixative tubes, which kills the cells, but preserves their morphology. Currently, the clinical utility of CTCs is mostly limited to their enumeration. More detailed investigation of CTC biology can be performed on live cells, but obtaining live CTCs is technically challenging, requiring blood collection into biocompatible solutions and rapid isolation which limits transportation options. To overcome the instability of CTCs, we formulated a sugar based cell transportation solution (SBTS) that stabilizes cell viability at ambient temperature. In this study we examined the long term viability of human cancer cell lines, primary cells and CTCs in human blood samples in the SBTS for transportation purposes. Four cell lines, 5 primary human cells and purified human PBMCs were tested to determine the viability of cells stored in the transportation solution at ambient temperature for up to 7 days. We then demonstrated viability of MCF-7 cells spiked into normal blood with SBTS and stored for up to 7 days. A pilot study was then run on blood samples from 3 patients with metastatic malignancies stored with or without SBTS for 6 days. CTCs were then purified by Ficoll separation/microfilter isolation and identified using CTC markers. Cell viability was assessed using trypan blue or CellTracker™ live cell stain. Our results suggest that primary/immortalized cell lines stored in SBTS remain ~90% viable for > 72 h. Further, MCF-7 cells spiked into whole blood remain viable when stored with SBTS for up to 7 days. Finally, live CTCs were isolated from cancer patient blood samples kept in SBTS at ambient temperature for 6 days. No CTCs were isolated from blood samples stored without SBTS. In this proof of principle pilot study we show that viability of cell lines is preserved for days using SBTS. Further, this solution can be used to store patient derived blood samples for eventual isolation of viable CTCs after

  5. Cryopreservation of human blood for alkaline and Fpg-modified comet assay.

    Science.gov (United States)

    Pu, Xinzhu; Wang, Zemin; Klaunig, James E

    2016-01-01

    The Comet assay is a reproducible and sensitive assay for the detection of DNA damage in eukaryotic cells and tissues. Incorporation of lesion specific, oxidative DNA damage repair enzymes (for example, Fpg, OGG1 and EndoIII) in the standard alkaline Comet assay procedure allows for the detection and measurement of oxidative DNA damage. The Comet assay using white blood cells (WBC) has proven useful in monitoring DNA damage from environmental agents in humans. However, it is often impractical to performance Comet assay immediately after blood sampling. Thus, storage of blood sample is required. In this study, we developed and tested a simple storage method for very small amount of whole blood for standard and Fpg-modified modified Comet assay. Whole blood was stored in RPMI 1640 media containing 10% FBS, 10% DMSO and 1 mM deferoxamine at a sample to media ratio of 1:50. Samples were stored at -20 °C and -80 °C for 1, 7, 14 and 28 days. Isolated lymphocytes from the same subjects were also stored under the same conditions for comparison. Direct DNA strand breakage and oxidative DNA damage in WBC and lymphocytes were analyzed using standard and Fpg-modified alkaline Comet assay and compared with freshly analyzed samples. No significant changes in either direct DNA strand breakage or oxidative DNA damage was seen in WBC and lymphocytes stored at -20 °C for 1 and 7 days compared to fresh samples. However, significant increases in both direct and oxidative DNA damage were seen in samples stored at -20 °C for 14 and 28 days. No changes in direct and oxidative DNA damage were observed in WBC and lymphocytes stored at -80 °C for up to 28 days. These results identified the proper storage conditions for storing whole blood or isolated lymphocytes to evaluate direct and oxidative DNA damage using standard and Fpg-modified alkaline Comet assay.

  6. Fire behavior of e-tablets stored in aircraft galley carts.

    Science.gov (United States)

    2015-04-01

    The use of electronic-tablets (e-tablets) as replacements for conventional in-flight entertainment systems has gained popularity : among airlines globally. Innovative methods of storing and charging e-tablets in galley carts have been suggested or ar...

  7. Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood.

    Science.gov (United States)

    Hussein, H A; Aamer, A A

    2013-01-01

    The present study was designed to investigate the effects of storage temperature and time on blood gas and acid-base balance of ovine venous blood. Ten clinically healthy sheep were used in this study. A total number of 30 blood samples, were divided into three different groups, and were stored in a refrigerator adjusted to +4 ºC (Group I, n = 10), at RT of about 22-25 ºC (Group II, n = 10) and in an incubator adjusted to 37 ºC (Group III, n = 10) for up to 48 h. Blood samples were analysed for blood gas and acid-base indices at 0, 1, 2, 3, 4, 5, 6, 12, 24 and 48 h of storage. In comparison to the baseline value (0), there were significant decreases of blood pH of samples stored at RT and in the incubator after 1 h (ppO2 values were significantly higher for Group I after 2 h and for Groups II and III after 1 h (preference range and it may be of clinical diagnostic use for up to 6 h.

  8. Accumulation of pro-cancer cytokines in the plasma fraction of stored packed red cells.

    Science.gov (United States)

    Benson, Douglas D; Beck, Adam W; Burdine, Marie S; Brekken, Rolf; Silliman, Christopher C; Barnett, Carlton C

    2012-03-01

    Perioperative blood transfusion has been linked to decreased survival in pancreatic cancer; however, the exact causal mechanism has not been elucidated. Allogeneic transfusions are known to expose patients to foreign cells and lipid mediators. We hypothesize that stored packed red cells (pRBCs) contain pro-cancer cytokines that augment tumor progression. We analyzed the plasma fraction of stored pRBCs for pro-cancer cytokines and evaluated the affect of both storage time and leukocyte reduction on these mediators. Chemiarray™ analysis for pro-cancer cytokines was performed on the acellular plasma fraction of stored leukocyte-reduced (LR) and non-leukocyte-reduced (NLR) pRBCs at day 1 (D.1-fresh) and day 42 (D.42-outdate) of storage. Elevated expression of monocyte chemotactic protein-1 (MCP-1), regulated on activation, normal T cell expressed and secreted (RANTES), angiogenin, tumor necrosis factor-alpha (TNF-α), epidermal growth factor (EGF), and platelet-derived growth factor (PDGF) was found. Specific enzyme-linked immunosorbent assay was performed for each of these factors in LR and NLR blood at D.1, day 28, and D.42. Data were analyzed by ANOVA. A p value ≤ 0.05 was considered significant; N ≥ 4 per group. Migration assays were performed using inhibitors of EGF (gefitinib) and PDGF (imatinib) on murine pancreatic adenocarcinoma cells (Pan02) exposed to D.1 and D.42 LR and NLR plasma. Proliferation assays were performed on Pan02 cells to test the inhibition of PDGF. MCP-1 levels increased with storage time in LR blood, 86.3 ± 6.3 pg/ml at D.1 vs. 121.2 ± 6.1 pg/ml at D.42 (p = 0.007), and NLR blood, 78.2 ± 7.3 pg/ml at D.1 vs. 647.8 ± 220.7 pg/ml at D.42 (p = 0.02). RANTES levels are lower in LR compared to NLR stored blood, 3.0 ± 1.9 vs. 15.8 ± 0.7 pg/ml at D.42 (p Pro-cancer cytokines that can augment tumor progression were identified in pRBCs. Some of these factors are present in fresh blood. The soluble factors identified herein may represent

  9. In vitro function of random donor platelets stored for 7 days in composol platelet additive solution

    Directory of Open Access Journals (Sweden)

    Gupta Ashish

    2011-01-01

    Full Text Available Background and Aim: Platelets are routinely isolated from whole blood and stored in plasma for 5 days. The present study was done to assess the in vitro function of random donor platelets stored for 7 days in composol platelet additive solution at 22°C. Materials and Methods: The study sample included 30 blood donors of both sex in State Blood Bank, CSM Medical University, Lucknow. Random donor platelets were prepared by platelet rich plasma method. Whole blood (350 ml was collected in anticoagulant Citrate Phosphate Dextrose Adenine triple blood bags. Random donor platelets were stored for 7 days at 22°C in platelet incubators and agitators, with and without additive solution. Results: Platelet swirling was present in all the units at 22°C on day 7, with no evidence of bacterial contamination. Comparison of the mean values of platelet count, platelet factor 3, lactate dehydrogenase, pH, glucose and platelet aggregation showed no significant difference in additive solution, whereas platelet factor 3, glucose and platelet aggregation showed significant difference (P < 0.001 on day 7 without additive solution at 22°C. Conclusion: Our study infers that platelet viability and aggregation were best maintained within normal levels on day 7 of storage in platelet additive solution at 22°C. Thus, we may conclude that in vitro storage of random donor platelets with an extended shelf life of 7 days using platelet additive solution may be advocated to improve the inventory of platelets.

  10. In vitro function of random donor platelets stored for 7 days in composol platelet additive solution

    Directory of Open Access Journals (Sweden)

    Gupta Ashish

    2011-01-01

    Full Text Available Background and Aim: Platelets are routinely isolated from whole blood and stored in plasma for 5 days. This study was done to assess the in vitro function of random donor platelets stored for 7 days in composol platelet additive solution at 22°C. Materials and Methods: The study sample included 30 blood donors of both sex in State Blood Bank, C S M Medical University, Lucknow. Random donor platelets were prepared by the platelet-rich plasma method. Whole blood (350 ml was collected in anticoagulant Citrate Phosphate Dextrose Adenine triple blood bags. Random donor platelets were stored for 7 days at 22°C in platelet incubators and agitators with and without additive solution. Results: Platelet swirling was present in all the units at 22°C on day 7 with no evidence of bacterial contamination. Comparison of the mean values of platelet count, platelet factor 3, lactate dehydrogenase, pH, glucose and platelet aggregation showed no significant difference in additive solution while platelet factor 3, glucose and platelet aggregation showed significant difference (P < 0.001 on day 7 without additive solution at 22°C. Conclusion: Our study infers that the platelet viability and aggregation were the best maintained within normal levels on day 7 of storage in platelet additive solution at 22°C. Thus, we may conclude that in vitro storage of random donor platelets with an extended shelf life of 7 days using platelet additive solution may be advocated to improve the inventory of platelets.

  11. Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

    Science.gov (United States)

    Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.

    2017-03-01

    Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

  12. The relationship between body iron stores and blood and urine cadmium concentrations in US never-smoking, non-pregnant women aged 20-49 years

    International Nuclear Information System (INIS)

    Gallagher, Carolyn M.; Chen, John J.; Kovach, John S.

    2011-01-01

    Background: Cadmium is a ubiquitous environmental pollutant associated with increased risk of leading causes of mortality and morbidity in women, including breast cancer and osteoporosis. Iron deficiency increases absorption of dietary cadmium, rendering women, who tend to have lower iron stores than men, more susceptible to cadmium uptake. We used body iron, a measure that incorporates both serum ferritin and soluble transferrin receptor, as recommended by the World Health Organization, to evaluate the relationships between iron status and urine and blood cadmium. Methods: Serum ferritin, soluble transferrin receptor, urine and blood cadmium values in never-smoking, non-pregnant, non-lactating, non-menopausal women aged 20-49 years (n=599) were obtained from the 2003-2008 National Health and Nutrition Examination Surveys. Body iron was calculated from serum ferritin and soluble transferrin receptor, and iron deficiency defined as body iron <0 mg/kg. Robust linear regression was used to evaluate the relationships between body iron and blood and urine cadmium, adjusted for age, race, poverty, body mass index, and parity. Results: Per incremental (mg/kg) increase in body iron, urine cadmium decreased by 0.003 μg/g creatinine and blood cadmium decreased by 0.014 μg/L. Iron deficiency was associated with 0.044 μg/g creatinine greater urine cadmium (95% CI=0.020, 0.069) and 0.162 μg/L greater blood cadmium (95% CI=0.132, 0.193). Conclusions: Iron deficiency is a risk factor for increased blood and urine cadmium among never-smoking, pre-menopausal, non-pregnant US women, independent of age, race, poverty, body mass index and parity. Expanding programs to detect and correct iron deficiency among non-pregnant women merits consideration as a potential means to reduce the risk of cadmium associated diseases. - Highlights: → Body iron was calculated from serum ferritin and soluble transferrin receptor. → Body iron was inversely associated with blood and urine cadmium

  13. The relationship between body iron stores and blood and urine cadmium concentrations in US never-smoking, non-pregnant women aged 20-49 years

    Energy Technology Data Exchange (ETDEWEB)

    Gallagher, Carolyn M., E-mail: 2crgallagher@optonline.net [PhD Program in Population Health and Clinical Outcomes Research, Stony Brook University, NY (United States) and Department of Preventive Medicine, Stony Brook University, Z-8036, Level 3, HSC, Stony Brook, NY 11794-8036 (United States); Chen, John J.; Kovach, John S. [Department of Preventive Medicine, Stony Brook University, Z-8036, Level 3, HSC, Stony Brook, NY 11794-8036 (United States)

    2011-07-15

    Background: Cadmium is a ubiquitous environmental pollutant associated with increased risk of leading causes of mortality and morbidity in women, including breast cancer and osteoporosis. Iron deficiency increases absorption of dietary cadmium, rendering women, who tend to have lower iron stores than men, more susceptible to cadmium uptake. We used body iron, a measure that incorporates both serum ferritin and soluble transferrin receptor, as recommended by the World Health Organization, to evaluate the relationships between iron status and urine and blood cadmium. Methods: Serum ferritin, soluble transferrin receptor, urine and blood cadmium values in never-smoking, non-pregnant, non-lactating, non-menopausal women aged 20-49 years (n=599) were obtained from the 2003-2008 National Health and Nutrition Examination Surveys. Body iron was calculated from serum ferritin and soluble transferrin receptor, and iron deficiency defined as body iron <0 mg/kg. Robust linear regression was used to evaluate the relationships between body iron and blood and urine cadmium, adjusted for age, race, poverty, body mass index, and parity. Results: Per incremental (mg/kg) increase in body iron, urine cadmium decreased by 0.003 {mu}g/g creatinine and blood cadmium decreased by 0.014 {mu}g/L. Iron deficiency was associated with 0.044 {mu}g/g creatinine greater urine cadmium (95% CI=0.020, 0.069) and 0.162 {mu}g/L greater blood cadmium (95% CI=0.132, 0.193). Conclusions: Iron deficiency is a risk factor for increased blood and urine cadmium among never-smoking, pre-menopausal, non-pregnant US women, independent of age, race, poverty, body mass index and parity. Expanding programs to detect and correct iron deficiency among non-pregnant women merits consideration as a potential means to reduce the risk of cadmium associated diseases. - Highlights: {yields} Body iron was calculated from serum ferritin and soluble transferrin receptor. {yields} Body iron was inversely associated with blood

  14. Screening for autologous blood transfusions

    DEFF Research Database (Denmark)

    Mørkeberg, J; Belhage, B; Ashenden, M

    2009-01-01

    parameter in the screening for autologous blood doping. Three bags of blood (approximately 201+/-11 g of Hb) were withdrawn from 16 males and stored at either -80 degrees C (-80 T, n=8) or +4 degrees C (+4 T, n=8) and reinfused 10 weeks or 4 weeks later, respectively. Seven subjects served as controls...

  15. Length of Storage of Red Blood Cells and Patient Survival After Blood Transfusion: A Binational Cohort Study.

    Science.gov (United States)

    Halmin, Märit; Rostgaard, Klaus; Lee, Brian K; Wikman, Agneta; Norda, Rut; Nielsen, Kaspar René; Pedersen, Ole B; Holmqvist, Jacob; Hjalgrim, Henrik; Edgren, Gustaf

    2017-02-21

    Possible negative effects, including increased mortality, among persons who receive stored red blood cells (RBCs) have recently garnered considerable attention. Despite many studies, including 4 randomized trials, no consensus exists. To study the association between the length of RBC storage and mortality in a large population-based cohort of patients who received transfusions, allowing detection of small yet clinically significant effects. Binational cohort study. All transfusion recipients in Sweden and Denmark. 854 862 adult patients who received transfusions from 2003 to 2012. Patients were followed from first blood transfusion. Relative and absolute risks for death in 30 days or 1 year in relation to length of RBC storage were assessed by using 3 independent analytic approaches. All analyses were conducted by using Cox proportional hazards regression. Regardless of the analytic approach, no association was found between the length of RBC storage and mortality. The difference in 30-day cumulative mortality between patients receiving blood stored for 30 to 42 days and those receiving blood stored for 10 to 19 days was -0.2% (95% CI, -0.5% to 0.1%). Even among patients who received more than 6 units of RBCs stored for 30 days or longer, the hazard ratio of death was 1.00 (CI, 0.96 to 1.05) compared with those who received no such units. Observational study; risk of confounding by indication. Consistent with previous randomized trials, this study found no association between the length of storage of transfused RBCs and patient mortality. Results were homogeneous, with differences in absolute mortality consistently less than 1% among the most extreme exposure categories. These findings suggest that the current practice of storing RBCs for up to 42 days does not need to be changed. The Swedish Research Council, Swedish Heart-Lung Foundation, Swedish Society for Medical Research, Strategic Research Program in Epidemiology at Karolinska Institutet, and Danish

  16. Identifying e-cigarette vape stores: description of an online search methodology.

    Science.gov (United States)

    Kim, Annice E; Loomis, Brett; Rhodes, Bryan; Eggers, Matthew E; Liedtke, Christopher; Porter, Lauren

    2016-04-01

    Although the overall impact of Electronic Nicotine Delivery Systems (ENDS) on public health is unclear, awareness, use, and marketing of the products have increased markedly in recent years. Identifying the increasing number of 'vape stores' that specialise in selling ENDS can be challenging given the lack of regulatory policies and licensing. This study assesses the utility of online search methods in identifying ENDS vape stores. We conducted online searches in Google Maps, Yelp, and YellowPages to identify listings of ENDS vape stores in Florida, and used a crowdsourcing platform to call and verify stores that primarily sold ENDS to consumers. We compared store listings generated from the online search and crowdsourcing methodology to list licensed tobacco and ENDS retailers from the Florida Department of Business and Professional Regulation. The combined results from all three online sources yielded a total of 403 ENDS vape stores. Nearly 32.5% of these stores were on the state tobacco licensure list, while 67.5% were not. Accuracy of online results was highest for Yelp (77.6%), followed by YellowPages (77.1%) and Google (53.0%). Using the online search methodology we identified more ENDS vape stores than were on the state tobacco licensure list. This approach may be a promising strategy to identify and track the growth of ENDS vape stores over time, especially in states without a systematic licensing requirement for such stores. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Electron cooling and elementary particle physics

    International Nuclear Information System (INIS)

    Budker, G.I.; Skrinskij, A.N.

    1978-01-01

    This review is devoted to a new method in experimental physics - the electron cooling. This method opens possibilities in storing the intense and highly monochromatic beams of heavy particles and allows to carry out a wide series of experiments of a high luminocity and resolution. The method is based on the beam cooling by an accompanying flux of electrons. The cooling is due to Coulomb collisions of the beam particles with electrons. In the first part the theoretical aspects of the method are considered shortly. The layout of the NAP-M installation with electron cooling and results of successful experiments on cooling the proton beam are given. In the second part the new possibilities are discussed which appear due to application of electron cooling: storing the intense antiproton beams and realization of the proton - antiproton colliding beams, carrying out experiments with the super fine targets in storage rings, experiments with particles and antiparticles at ultimately low energies, storing the polarized antiprotons and other particles, production of antiatoms, antideuton storing, experiments with ion beams

  18. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... If you find that you are interested in learning more about blood diseases and disorders, here are ... 0544 | Fax 202-776-0545 ASH Store ASH Job Center ASH Apps Share Your Idea Donate Research ...

  19. Systems biology of stored blood cells: can it help to extend the expiration date?

    Science.gov (United States)

    Paglia, Giuseppe; Palsson, Bernhard Ø; Sigurjonsson, Olafur E

    2012-12-05

    With increasingly stringent regulations regarding deferral and elimination of blood donors it will become increasingly important to extend the expiration date of blood components beyond the current allowed storage periods. One reason for the storage time limit for blood components is that platelets and red blood cells develop a condition called storage lesions during their storage in plastic blood containers. Systems biology provides comprehensive bio-chemical descriptions of organisms through quantitative measurements and data integration in mathematical models. The biological knowledge for a target organism can be translated in a mathematical format and used to compute physiological properties. The use of systems biology represents a concrete solution in the study of blood cell storage lesions, and it may open up new avenues towards developing better storage methods and better storage media, thereby extending the storage period of blood components. This article is part of a Special Issue entitled: Integrated omics. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. A genetic risk factor for low serum ferritin levels in Danish blood donors

    DEFF Research Database (Denmark)

    Sørensen, Erik; Grau, Katrine; Berg, Trine

    2012-01-01

    BACKGROUND: Iron deficiency is a frequent side effect of blood donation. In recent years, several studies have described genetic variants associated with iron concentrations. However, the impact of these variants on iron levels is unknown in blood donors. Knowledge of genetic variants....../or restless leg syndrome (RLS) were investigated in two groups of female blood donors. The first group had low iron stores (serum ferritin ≤ 12 µg/L, n = 657), and the second group had normal to high iron stores (serum ferritin > 30 µg/L, n = 645). Genotype distribution for each of the SNPs was compared......: A frequent polymorphism in BTBD9 was significantly associated with serum ferritin. This polymorphism has previously been associated with RLS, but not low iron stores in blood donors....

  1. Effects of helicopter transport on red blood cell components.

    Science.gov (United States)

    Otani, Taiichi; Oki, Ken-ichi; Akino, Mitsuaki; Tamura, Satoru; Naito, Yuki; Homma, Chihiro; Ikeda, Hisami; Sumita, Shinzou

    2012-01-01

    There are no reported studies on whether a helicopter flight affects the quality and shelf-life of red blood cells stored in mannitol-adenine-phosphate. Seven days after donation, five aliquots of red blood cells from five donors were packed into an SS-BOX-110 container which can maintain the temperature inside the container between 2 °C and 6 °C with two frozen coolants. The temperature of an included dummy blood bag was monitored. After the box had been transported in a helicopter for 4 hours, the red blood cells were stored again and their quality evaluated at day 7 (just after the flight), 14, 21 and 42 after donation. Red blood cell quality was evaluated by measuring adenosine triphosphate, 2,3-diphosphoglycerate, and supernatant potassium, as well as haematocrit, intracellular pH, glucose, supernatant haemoglobin, and haemolysis rate at the various time points. During the experiment the recorded temperature remained between 2 and 6 °C. All data from the red blood cells that had undergone helicopter transportation were the same as those from a control group of red blood cell samples 7 (just after the flight), 14, 21, and 42 days after the donation. Only supernatant Hb and haemolysis rate 42 days after the donation were slightly increased in the helicopter-transported group of red blood cell samples. All other parameters at 42 days after donation were the same in the two groups of red blood cells. These results suggest that red blood cells stored in mannitol-adenine-phosphate are not significantly affected by helicopter transportation. The differences in haemolysis by the end of storage were small and probably not of clinical significance.

  2. CORPORATE REBRANDING OF GRAMEDIA STORE (CORPORATE REBRANDING DI GRAMEDIA STORE

    Directory of Open Access Journals (Sweden)

    Natasha Helena Kairupan

    2016-10-01

    Full Text Available Abstract. The purposes of this research are to determine the stages of analysis, planning, and evaluation of corporate rebranding process of Gramedia Book Store to be Gramedia Store to rise stakeholder’s awareness. The method used is descriptive qualitative with positivism paradigm. The technique of collecting data through in-depth interview, observation, and literature study. The result of this research showed the analysis stage by analyzing the market through insights and foresights, brand audit through SWOT analysis, and identifying opportunities. The planning stage is by determine the purpose of the planning process and then determine the target audience, consist of external and internal customer. The planning of external customer by renaming and change of corporate identity, and marketing planning using communication channel (above the line and below the line. The planning of internal customer by Brand Induction, training, inspiration briefing at store, and innovation competition. The evaluation of rebranding process of Gramedia Store is having a focus group discussion with customer, media monitoring, and presentation to BOD. Keywords : Process, Corporate Rebranding, Stakeholder Awareness, Corporate Identity, Gramedia Store Abstrak.Tujuan penelitian ini adalah untuk mengetahui bagaimana tahapan analisis, perencanaan, dan evaluasi proses corporate rebranding Gramedia Book Store menjadi Gramedia Store untuk meningkatkan stakeholder awareness. Pendekatan yang digunakan adalah kualitatif dengan paradigma positivisme dan jenis studi deksriptif. Teknik pengumpulan data yang dilakukan melalui wawancara mendalam, observasi, dan studi pustaka. Berdasarkan hasil penelitian, tahapan analisis dilakukan dengan menganalisis pasar melalui insights dan foresights, audit merek dengan analisis SWOT, dan mengidentifikasi peluang. Dalam tahapan perencanaan dengan menentukan tujuan kemudian menentukan target audiens, yaitu eksternal dan internal. Perencanaan

  3. Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood

    Directory of Open Access Journals (Sweden)

    H.A. Hussein

    2013-01-01

    Full Text Available The present study was designed to investigate the effects of storage temperature and time on blood gas and acid-base balance of ovine venous blood. Ten clinically healthy sheep were used in this study. A total number of 30 blood samples, were divided into three different groups, and were stored in a refrigerator adjusted to +4 ºC (Group I, n = 10, at RT of about 22-25 ºC (Group II, n = 10 and in an incubator adjusted to 37 ºC (Group III, n = 10 for up to 48 h. Blood samples were analysed for blood gas and acid-base indices at 0, 1, 2, 3, 4, 5, 6, 12, 24 and 48 h of storage. In comparison to the baseline value (0, there were significant decreases of blood pH of samples stored at RT and in the incubator after 1 h (p<0.05, the pH value of refrigerated blood samples exhibited insignificant changes during the study (p<0.05. Mean values of pCO2 showed a significant increase in Group I and Group III after 1 h then a progressive decrease after 12 h in all Groups. Mean pO2 values were significantly higher for Group I after 2 h and for Groups II and III after 1 h (p<0.05. In general, base excess decreased significantly for all the groups during the study especially in Groups II and III. In comparison with baseline values, in all groups, bicarbonate (HCO3 increased between 1 h and 6 h (p<0.05, and later decreased at the end of the study (p<0.05. In conclusion, status of acid-base indices of the samples stored at refrigerator and RT were found within normal reference range and it may be of clinical diagnostic use for up to 6 h.

  4. Energy saving by optimized controls for supermarket stores; Energie sparen mit optimierter Regeltechnik im Supermarkt

    Energy Technology Data Exchange (ETDEWEB)

    Wendelborn, Horst [Danfoss GmbH, Offenbach (Germany)

    2011-06-15

    Danfoss has been delivering for 20 years the optimizing ADAP-KOOL(R) control system. It enables the store to save 30% of the yearly energy bill, compared to a store with electronic standard controls. Over years the stores took the cheap standard solution, but now several German supermarket chains decide to take the best for the investment and lifecycle cost. This article describes the main control circuits and shows the measurements of the energy consumption of two stores with standard and optimized controls. This control system is available for chemical and for the natural refrigerant R744. (orig.)

  5. Food and beverage purchases in corner stores, gas-marts, pharmacies and dollar stores.

    Science.gov (United States)

    Caspi, Caitlin E; Lenk, Kathleen; Pelletier, Jennifer E; Barnes, Timothy L; Harnack, Lisa; Erickson, Darin J; Laska, Melissa N

    2017-10-01

    Little is known about customer purchases of foods and beverages from small and non-traditional food retailers (i.e. corner stores, gas-marts, dollar stores and pharmacies). The present study aimed to: (i) describe customer characteristics, shopping frequency and reasons for shopping at small and non-traditional food retailers; and (ii) describe food/beverage purchases and their nutritional quality, including differences across store type. Data were collected through customer intercept interviews. Nutritional quality of food/beverage purchases was analysed; a Healthy Eating Index-2010 (HEI-2010) score for purchases was created by aggregating participant purchases at each store. Small and non-traditional food stores that were not WIC-authorized in Minneapolis and St. Paul, MN, USA. Customers (n 661) from 105 food retailers. Among participants, 29 % shopped at the store at least once daily; an additional 44 % shopped there at least once weekly. Most participants (74 %) cited convenient location as the primary draw to the store. Customers purchased a median of 2262 kJ (540 kcal), which varied by store type (P=0·04). The amount of added sugar far surpassed national dietary recommendations. At dollar stores, participants purchased a median of 5302 kJ (1266 kcal) for a median value of $US 2·89. Sugar-sweetened beverages were the most common purchase. The mean HEI-2010 score across all stores was 36·4. Small and non-traditional food stores contribute to the urban food environment. Given the poor nutritional quality of purchases, findings support the need for interventions that address customer decision making in these stores.

  6. Association between store food environment and customer purchases in small grocery stores, gas-marts, pharmacies and dollar stores.

    Science.gov (United States)

    Caspi, Caitlin E; Lenk, Kathleen; Pelletier, Jennifer E; Barnes, Timothy L; Harnack, Lisa; Erickson, Darin J; Laska, Melissa N

    2017-06-05

    Purchases at small/non-traditional food stores tend to have poor nutritional quality, and have been associated with poor health outcomes, including increased obesity risk The purpose of this study was to examine whether customers who shop at small/non-traditional food stores with more health promoting features make healthier purchases. In a cross-sectional design, data collectors assessed store features in a sample of 99 small and non-traditional food stores not participating in the Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) in Minneapolis/St. Paul, MN in 2014. Customer intercept interviews (n = 594) collected purchase data from a bag check and demographics from a survey. Store measures included fruit/vegetable and whole grain availability, an overall Healthy Food Supply Score (HFSS), healthy food advertisements and in-store placement, and shelf space of key items. Customer nutritional measures were analyzed using Nutrient Databases System for Research (NDSR), and included the purchase of ≥1 serving of fruits/vegetables; ≥1 serving of whole grains; and overall Healthy Eating Index-2010 (HEI-2010) score for foods/beverages purchased. Associations between store and customer measures were estimated in multilevel linear and logistic regression models, controlling for customer characteristics and store type. Few customers purchased fruits and vegetables (8%) or whole grains (8%). In fully adjusted models, purchase HEI-2010 scores were associated with fruit/vegetable shelf space (p = 0.002) and the ratio of shelf space devoted to healthy vs. less healthy items (p = 0.0002). Offering ≥14 varieties of fruit/vegetables was associated with produce purchases (OR 3.9, 95% CI 1.2-12.3), as was having produce visible from the store entrance (OR 2.3 95% CI 1.0 to 5.8), but whole grain availability measures were not associated with whole grain purchases. Strategies addressing both customer demand and the availability of healthy food

  7. Using a Virtual Store As a Research Tool to Investigate Consumer In-store Behavior.

    Science.gov (United States)

    Ploydanai, Kunalai; van den Puttelaar, Jos; van Herpen, Erica; van Trijp, Hans

    2017-07-24

    People's responses to products and/or choice environments are crucial to understanding in-store consumer behaviors. Currently, there are various approaches (e.g., surveys or laboratory settings) to study in-store behaviors, but the external validity of these is limited by their poor capability to resemble realistic choice environments. In addition, building a real store to meet experimental conditions while controlling for undesirable effects is costly and highly difficult. A virtual store developed by virtual reality techniques potentially transcends these limitations by offering the simulation of a 3D virtual store environment in a realistic, flexible, and cost-efficient way. In particular, a virtual store interactively allows consumers (participants) to experience and interact with objects in a tightly controlled yet realistic setting. This paper presents the key elements of using a desktop virtual store to study in-store consumer behavior. Descriptions of the protocol steps to: 1) build the experimental store, 2) prepare the data management program, 3) run the virtual store experiment, and 4) organize and export data from the data management program are presented. The virtual store enables participants to navigate through the store, choose a product from alternatives, and select or return products. Moreover, consumer-related shopping behaviors (e.g., shopping time, walking speed, and number and type of products examined and bought) can also be collected. The protocol is illustrated with an example of a store layout experiment showing that shelf length and shelf orientation influence shopping- and movement-related behaviors. This demonstrates that the use of a virtual store facilitates the study of consumer responses. The virtual store can be especially helpful when examining factors that are costly or difficult to change in real life (e.g., overall store layout), products that are not presently available in the market, and routinized behaviors in familiar

  8. How safe is the blood supply?

    Science.gov (United States)

    1992-06-26

    Many poor people in Indian cities sell their blood to commercial blood banks for up to US$2.50. In fact, so many have done so that there once was a Professional Blood Donors Association. It dissolved though after some members died of AIDS. Health workers believe at least 25% of blood donors in Bombay are HIV positive. Yet a recent study of 70 professional blood donors in Bombay shows only 7 who did not test positive for HIV. Still the government of India does not require blood banks to test for HIV, hepatitis, or other blood borne diseases. In fact, the blood supply is monitored in only 5 cities in India. In India as well as in other Asian countries, physicians advise patients to donate their own blood and have it stored until needed for surgery or to ask for safer blood substitutes, e.g., plasma expanders. In fact, in Singapore, the Autologous Blood Bank charges US$21/year to store units of blood for future use. In Japan, most of the 2008 HIV infected people had received blood plasma from mainly the US before Japan required new sterilization regulations on blood imports. The greatest risk from blood donors comes from those who are paid for their blood because they tend to be poor, to practice unsafe sex, and not to be mindful of their health. Most Asian nations such as Japan and Singapore do screen the blood supply. Further, for almost 20 years, Thailand has checked its blood supply for hepatitis B and syphilis. In 1987, it began testing for AIDS. It does not pay for donated blood. In the Philippines, however, even paying blood donors does not meet the needed blood supply and much of the blood comes from commercial blood banks. Yet the Philippine Red Cross has screened for other diseases since 1960 and for AIDS since 1988.

  9. Effects of helicopter transport on red blood cell components

    Science.gov (United States)

    Otani, Taiichi; Oki, Ken-ichi; Akino, Mitsuaki; Tamura, Satoru; Naito, Yuki; Homma, Chihiro; Ikeda, Hisami; Sumita, Shinzou

    2012-01-01

    Background There are no reported studies on whether a helicopter flight affects the quality and shelf-life of red blood cells stored in mannitol-adenine-phosphate. Materials and methods Seven days after donation, five aliquots of red blood cells from five donors were packed into an SS-BOX-110 container which can maintain the temperature inside the container between 2 °C and 6 °C with two frozen coolants. The temperature of an included dummy blood bag was monitored. After the box had been transported in a helicopter for 4 hours, the red blood cells were stored again and their quality evaluated at day 7 (just after the flight), 14, 21 and 42 after donation. Red blood cell quality was evaluated by measuring adenosine triphosphate, 2,3-diphosphoglycerate, and supernatant potassium, as well as haematocrit, intracellular pH, glucose, supernatant haemoglobin, and haemolysis rate at the various time points. Results During the experiment the recorded temperature remained between 2 and 6 °C. All data from the red blood cells that had undergone helicopter transportation were the same as those from a control group of red blood cell samples 7 (just after the flight), 14, 21, and 42 days after the donation. Only supernatant Hb and haemolysis rate 42 days after the donation were slightly increased in the helicopter-transported group of red blood cell samples. All other parameters at 42 days after donation were the same in the two groups of red blood cells. Discussion These results suggest that red blood cells stored in mannitol-adenine-phosphate are not significantly affected by helicopter transportation. The differences in haemolysis by the end of storage were small and probably not of clinical significance. PMID:22153688

  10. Donation intensity and metabolic syndrome in active whole-blood donors

    NARCIS (Netherlands)

    Peffer, K.; Verbeek, A.L.M.; Swinkels, D.W.; Geurts-Moespot, A.J.; den Heijer, M.; Atsma, F.

    2015-01-01

    Background and Objectives: Increased iron and metabolic syndrome (MetS) go hand in hand. Frequent blood donation depletes iron stores. This study investigates whether high-intensity blood donation is associated with lower MetS prevalence compared with low-intensity blood donation, and whether iron

  11. Polarizing a stored proton beam by spin flip? - A high statistic reanalysis

    International Nuclear Information System (INIS)

    Oellers, Dieter

    2011-01-01

    Prompted by recent, conflicting calculations, we have carried out a measurement of the spin flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. A reanalysis of the data leeds to a reduced statistical errors resulting in a factor of 4 reduced upper limit for the spin flip cross section. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam.

  12. Get the Most Out of Home Blood Pressure Monitoring

    Science.gov (United States)

    Get the most out of home blood pressure monitoring Checking your blood pressure at home is an important part of managing ... monitors might not give you an accurate reading. Most pharmacies, medical supply stores and some websites sell ...

  13. Dried blood spots as a source of anti-malarial antibodies for epidemiological studies

    Science.gov (United States)

    Corran, Patrick H; Cook, Jackie; Lynch, Caroline; Leendertse, Heleen; Manjurano, Alphaxard; Griffin, Jamie; Cox, Jonathan; Abeku, Tarekegn; Bousema, Teun; Ghani, Azra C; Drakeley, Chris; Riley, Eleanor

    2008-01-01

    Background Blood spots collected onto filter paper are an established and convenient source of antibodies for serological diagnosis and epidemiological surveys. Although recommendations for the storage and analysis of small molecule analytes in blood spots exist, there are no published systematic studies of the stability of antibodies under different storage conditions. Methods Blood spots, on filter paper or glass fibre mats and containing malaria-endemic plasma, were desiccated and stored at various temperatures for different times. Eluates of these spots were assayed for antibodies against two Plasmodium falciparum antigens, MSP-119 and MSP2, and calculated titres used to fit an exponential (first order kinetic) decay model. The first order rate constants (k) for each spot storage temperature were used to fit an Arrhenius equation, in order to estimate the thermal and temporal stability of antibodies in dried blood spots. The utility of blood spots for serological assays was confirmed by comparing antibodies eluted from blood spots with the equivalent plasma values in a series of samples from North Eastern Tanzania and by using blood spot-derived antibodies to estimate malaria transmission intensity in this site and for two localities in Uganda. Results Antibodies in spots on filter paper and glass fibre paper had similar stabilities but blood was more easily absorbed onto filter papers than glass fibre, spots were more regular and spot size was more closely correlated with blood volume for filter paper spots. Desiccated spots could be stored at or below 4°C for extended periods, but were stable for only very limited periods at ambient temperature. When desiccated, recoveries of antibodies that are predominantly of IgG1 or IgG3 subclasses were similar. Recoveries of antibodies from paired samples of serum and of blood spots from Tanzania which had been suitably stored showed similar recoveries of antibodies, but spots which had been stored for extended periods

  14. Thermal annealing of high dose radiation induced damage at room temperature in alkaline. Stored energy, thermoluminescence and coloration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminescence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminescence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KC1 samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose.Capacity of alkali halides to store energy by irradiation increases as the cation size decreases. (Author) 51 refs

  15. [Alternatives to allogenous blood transfusion].

    Science.gov (United States)

    Cernea, Daniela; Vlădoianu, Alice; Stoica, Maria; Novac, M; Berteanu, Cristina

    2009-01-01

    Blood transfusion is usually meant to lower morbidity and mortality rates. Allogenous blood transfusion implies certain risks that can be avoided by autologous blood transfusions techniques including: preoperatory autologous blood donation, acute normovolemic hemodilution, intraoperatory and postoperatory blood salvage. Preoperatory blood donation and acute normovolemic hemodilution are used for planned interventions with an estimated blood loss higher than 20% of blood volume. These methods imply Erythropoietin and iron treatment. Intraoperatory and postoperatory blood salvage is performed by personnel trained in blood donation, handling and storage. Autologous blood transfusions are used for certain surgical procedures that commonly require transfusions: orthopedic surgery, radical prostatectomy, cardiovascular surgery, organ transplantation. An alternative to allogenous blood transfusion is the use of artificial oxygen transporters: human or animal hemoglobin solutions or pefluorocarbonate solutions. These solutions do not require cross reactions, do not carry diseases and are generally well tolerated and easily stored in the operating room, ambulance and other transport means. They have however a slight degree of toxicity.

  16. Storage time of transfused blood and disease recurrence after colorectal cancer surgery

    DEFF Research Database (Denmark)

    Mynster, T; Nielsen, Hans Jørgen

    2001-01-01

    of the transfused blood. Therefore, we studied the relationship between blood storage time and the development of disease recurrence and long-term survival after colorectal cancer surgery. METHODS: Preoperative and postoperative data were prospectively recorded in 740 patients undergoing elective resection......BACKGROUND: Perioperative blood transfusion and subsequent development of postoperative infectious complications may lead to poor prognosis of patients with colorectal cancer. It has been suggested that the development of postoperative infectious complications may be related to the storage time...... transfused patients (P = 0.004). The survival of patients receiving blood exclusively stored blood stored > or = 21 days, survival was 3.7 years (P = 0.12). Among patients with curative resection (n = 532), the hazard ratio of disease recurrence was 1.5 (95...

  17. Feasibility of Using the Mosquito Blood Meal for Rapid and Efficient Human and Animal Virus Surveillance and Discovery

    Science.gov (United States)

    Yang, Yu; Garver, Lindsey S.; Bingham, Karen M.; Hang, Jun; Jochim, Ryan C.; Davidson, Silas A.; Richardson, Jason H.; Jarman, Richard G.

    2015-01-01

    Mosquito blood meals taken from humans and animals potentially represent a useful source of blood for the detection of blood-borne pathogens. In this feasibility study, Anopheles stephensi mosquitoes were fed with blood meals spiked with dengue virus type 2 (DENV-2) and harvested at serial time points. These mosquitoes are not competent vectors, and the virus is not expected to replicate. Ingested blood was spotted on Whatman FTA cards and stored at room temperature. Mosquito abdomens were removed and stored at −80°C. Control blood meal aliquots were stored in vials or applied onto FTA cards. After 4 weeks of storage, the samples were extracted using beadbeating and QIAamp Viral RNA kit (Qiagen Sciences, Germantown, MD). Recovered viral RNA was analyzed by DENV-2 TaqMan RT-PCR assay and next-generation sequencing (NGS). Overall viral RNA recovery efficiency was 15% from the directly applied dried blood spots and approximately 20% or higher for dried blood spots made by blotting mosquito midgut on FTA cards. Viral RNA in mosquito-ingested blood decreases over time, but remains detectable 24 hours after blood feeding. The viral sequences in FTA-stored specimens can be maintained at room temperature. The strategy has the potential utility in expedited zoonotic virus discovery and blood-borne pathogen surveillance. PMID:26416112

  18. Low iron stores are related to higher blood concentrations of manganese, cobalt and cadmium in non-smoking, Norwegian women in the HUNT 2 study

    International Nuclear Information System (INIS)

    Margrete Meltzer, Helle; Lise Brantsaeter, Anne; Borch-Iohnsen, Berit; Ellingsen, Dag G.; Alexander, Jan; Thomassen, Yngvar; Stigum, Hein; Ydersbond, Trond A.

    2010-01-01

    Low iron (Fe) stores may influence absorption or transport of divalent metals in blood. To obtain more knowledge about such associations, the divalent metal ions cadmium (Cd), manganese (Mn), cobalt (Co), copper (Cu), zinc (Zn) and lead (Pb) and parameters of Fe metabolism (serum ferritin, haemoglobin (Hb) and transferrin) were investigated in 448 healthy, menstruating non-smoking women, age 20-55 years (mean 38 years), participating in the Norwegian HUNT 2 study. The study population was stratified for serum ferritin: 257 were iron-depleted (serum ferritin 2 for the models were 0.28, 0.48 and 0.34, respectively. Strong positive associations between blood concentrations of Mn, Co and Cd were observed, also when controlled for their common association with ferritin. Apart from these associations, the models showed no significant interactions between the six divalent metals studied. Very mild anaemia (110≤Hb<120 g/L) did not seem to have any effect independent of low ferritin. Approximately 26% of the women with iron deficiency anaemia had high concentrations of all of Mn, Co and Cd as opposed to 2.3% of iron-replete subjects. The results confirm that low serum ferritin may have an impact on body kinetics of certain divalent metal ions, but not all. Only a fraction of women with low iron status exhibited an increased blood concentration of divalent metals, providing indication of complexities in the body's handling of these metals.

  19. Calcium in drinking water: effect on iron stores in Danish blood donors-results from the Danish Blood Donor Study.

    Science.gov (United States)

    Rigas, Andreas S; Ejsing, Benedikte H; Sørensen, Erik; Pedersen, Ole B; Hjalgrim, Henrik; Erikstrup, Christian; Ullum, Henrik

    2018-03-25

    Studies confirm that calcium inhibits iron absorption. Danish tap water comes from groundwater, which contains varying amounts of calcium depending on the subsoil. We investigated the association of calcium in drinking water with iron levels in Danish blood donors. We used data on Danish blood donors including dietary and lifestyle habits, blood donation history, and physiologic characteristics including measures of ferritin levels along with information on area of residence from The Danish Blood Donor Study. Data on calcium levels in groundwater ("water hardness") were obtained through the Geological Survey of Denmark and Greenland. We performed multiple linear and logistic regression analyses to evaluate the effect of water hardness on ferritin levels and risk of having iron deficiency (defined as ferritin levels water hardness and ferritin levels in both men and women. Risk of iron deficiency was correspondingly increased in both men (odds ratio [OR], 1.55; 95% confidence interval [CI], 1.14-2.12) and women (OR, 1.20; 95% CI, 1.03-1.40) with increasing water hardness. In analyses restricted to individuals who received supplemental iron tablets no significant association between groundwater hardness and ferritin levels was observed. As measured by ferritin levels, residential drinking water calcium content is associated with blood donors- iron levels and risk of iron deficiency. However, effect sizes are small. © 2018 AABB.

  20. Present and Future Experiments with Stored Exotic Nuclei at GSI

    International Nuclear Information System (INIS)

    Geissel, H.

    2009-01-01

    Recent results and perspectives of experiments with stored exotic nuclei at GSI-FAIR will presented. An overview on the planned NUSTAR experiments will also presented. Relativistic exotic nuclei produced via projectile fragmentation and fission were separated in flight by the fragment separator FRS and injected into the storage-cooler ring ESR for accurate mass- and lifetime measurements. Direct mass measurements of electron-cooled exotic nuclei were performed using time-resolved Schottky spectrometry. Fragments with half-lives shorter than the time required for electron cooling have been investigated by time-of-flight measurements with the ESR being operated in the isochronous mode. This novel experimental technique gives access to all nuclei with half-lives down to the microsecond range and has been successfully applied. Lifetimes of stored bare and few-electron ions have been measured with the goal to study the beta-decay under ionization conditions prevailing in stellar plasma. For the first time the direct observation of bound-state beta decay has been achieved with 2 07T l fragments. The future project FAIR includes a new large-acceptance in-flight separator (Super-FRS) in combination with a new storage ring system (CR, NESR) which will be ideal tools to study exotic nuclei far from stability.(author)

  1. Effect of meals with milk on body iron stores and improvement of dietary habit during weight loss in female rhythmic gymnasts.

    Science.gov (United States)

    Kawano, Yukari; Ishizaki, Sakuko; Sasamoto, Shigeko; Katoh, Youko; Kobayashi, Shuhei

    2002-10-01

    This study investigated the effect of different timings of milk intake on body iron stores and improvement in the dietary habit of female collegiate rhythmic gymnasts. Subjects took iron tablets at both breakfast and dinner times during a weight-loss period. In addition, subjects ingested low-fat milk twice a day either at breakfast or dinner (group I; n = 7), or between meals (group II; n = 6) for 3 mo. Blood was collected four times. Red blood cell count, hemoglobin, serum iron, ferritin and erythropoietin concentrations were measured. Subjects completed a dietary survey for three consecutive days before each blood sampling. The mean body fat in both groups I and II was significantly lower after 3 mo than at the start of the study (p meals. In conclusion, iron-supplemented meals via milk ingestion did not decrease body iron stores and maintained higher body iron stores compared to a diet that included milk intake between meals. Further, milk intake with meals is related to keeping regular meal times and frequency.

  2. The effects of cryopreservation on red blood cell rheologic properties

    NARCIS (Netherlands)

    Henkelman, Sandra; Lagerberg, Johan W. M.; Graaff, Reindert; Rakhorst, Gerhard; van Oeveren, Willem

    2010-01-01

    BACKGROUND: In transfusion medicine, frozen red blood cells (RBCs) are an alternative for liquid-stored RBCs. Little is known about the rheologic properties (i.e., aggregability and deformability) of thawed RBCs. In this study the rheologic properties of high-glycerol frozen RBCs and postthaw stored

  3. Field study of dried blood spot specimens for HIV-1 drug resistance genotyping.

    Science.gov (United States)

    Parry, C M; Parkin, N; Diallo, K; Mwebaza, S; Batamwita, R; DeVos, J; Bbosa, N; Lyagoba, F; Magambo, B; Jordan, M R; Downing, R; Zhang, G; Kaleebu, P; Yang, C; Bertagnolio, S

    2014-08-01

    Dried blood spots (DBS) are an alternative specimen type for HIV drug resistance genotyping in resource-limited settings. Data relating to the impact of DBS storage and shipment conditions on genotyping efficiency under field conditions are limited. We compared the genotyping efficiencies and resistance profiles of DBS stored and shipped at different temperatures to those of plasma specimens collected in parallel from patients receiving antiretroviral therapy in Uganda. Plasma and four DBS cards from anti-coagulated venous blood and a fifth card from finger-prick blood were prepared from 103 HIV patients with a median viral load (VL) of 57,062 copies/ml (range, 1,081 to 2,964,191). DBS were stored at ambient temperature for 2 or 4 weeks or frozen at -80 °C and shipped from Uganda to the United States at ambient temperature or frozen on dry ice for genotyping using a broadly sensitive in-house method. Plasma (97.1%) and DBS (98.1%) stored and shipped frozen had similar genotyping efficiencies. DBS stored frozen (97.1%) or at ambient temperature for 2 weeks (93.2%) and shipped at ambient temperature also had similar genotyping efficiencies. Genotyping efficiency was reduced for DBS stored at ambient temperature for 4 weeks (89.3%, P = 0.03) or prepared from finger-prick blood and stored at ambient temperature for 2 weeks (77.7%, P blood and handled similarly. Resistance profiles were similar between plasma and DBS specimens. This report delineates the optimal DBS collection, storage, and shipping conditions and opens a new avenue for cost-saving ambient-temperature DBS specimen shipments for HIV drug resistance (HIVDR) surveillances in resource-limited settings. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  4. Family-directed umbilical cord blood banking.

    Science.gov (United States)

    Gluckman, Eliane; Ruggeri, Annalisa; Rocha, Vanderson; Baudoux, Etienne; Boo, Michael; Kurtzberg, Joanne; Welte, Kathy; Navarrete, Cristina; van Walraven, Suzanna M

    2011-11-01

    Umbilical cord blood transplantation from HLA-identical siblings provides good results in children. These results support targeted efforts to bank family cord blood units that can be used for a sibling diagnosed with a disease which can be cured by allogeneic hematopoietic stem cell transplantation or for research that investigates the use of allogeneic or autologous cord blood cells. Over 500 patients transplanted with related cord blood units have been reported to the Eurocord registry with a 4-year overall survival of 91% for patients with non-malignant diseases and 56% for patients with malignant diseases. Main hematologic indications in children are leukemia, hemoglobinopathies or inherited hematologic, immunological or metabolic disorders. However, family-directed cord blood banking is not widely promoted; many cord blood units used in sibling transplantation have been obtained from private banks that do not meet the necessary criteria required to store these units. Marketing by private banks who predominantly store autologous cord blood units has created public confusion. There are very few current validated indications for autologous storage but some new indications might appear in the future. Little effort is devoted to provide unbiased information and to educate the public as to the distinction between the different types of banking, economic models and standards involved in such programs. In order to provide a better service for families in need, directed-family cord blood banking activities should be encouraged and closely monitored with common standards, and better information on current and future indications should be made available.

  5. Storing quantum information in spins and high-sensitivity ESR

    Science.gov (United States)

    Morton, John J. L.; Bertet, Patrice

    2018-02-01

    Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per √{ Hz } , with prospects to scale down to even fewer spins.

  6. Storing quantum information in spins and high-sensitivity ESR.

    Science.gov (United States)

    Morton, John J L; Bertet, Patrice

    2018-02-01

    Quantum information, encoded within the states of quantum systems, represents a novel and rich form of information which has inspired new types of computers and communications systems. Many diverse electron spin systems have been studied with a view to storing quantum information, including molecular radicals, point defects and impurities in inorganic systems, and quantum dots in semiconductor devices. In these systems, spin coherence times can exceed seconds, single spins can be addressed through electrical and optical methods, and new spin systems with advantageous properties continue to be identified. Spin ensembles strongly coupled to microwave resonators can, in principle, be used to store the coherent states of single microwave photons, enabling so-called microwave quantum memories. We discuss key requirements in realising such memories, including considerations for superconducting resonators whose frequency can be tuned onto resonance with the spins. Finally, progress towards microwave quantum memories and other developments in the field of superconducting quantum devices are being used to push the limits of sensitivity of inductively-detected electron spin resonance. The state-of-the-art currently stands at around 65 spins per Hz, with prospects to scale down to even fewer spins. Copyright © 2017. Published by Elsevier Inc.

  7. Tobacco advertising in retail stores.

    Science.gov (United States)

    Cummings, K M; Sciandra, R; Lawrence, J

    1991-01-01

    Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were surveyed to determine their store's policy regarding tobacco advertising, receipt of monetary incentives from distributors for displaying tobacco ads, and willingness to display antitobacco ads. Six types of stores were involved in the study: 10 supermarkets, 10 privately owned grocery stores, 9 chain convenience food stores that do not sell gasoline, 11 chain convenience food stores that sell gasoline, 11 chain pharmacies, and 10 private pharmacies. Two-thirds of the stores displayed tobacco posters, and 87 percent had promotional items advertising tobacco products, primarily cigarettes. Larger stores, and those that were privately owned, tended to display more posters and promotional items. Eighty percent of tobacco product displays were for cigarettes, 16 percent for smokeless tobacco products, and 4 percent for cigars and pipe tobacco. Convenience stores selling gasoline had the most separate tobacco product displays. Of tobacco product displays, 24 percent were located adjacent to candy and snack displays. Twenty-nine of the 61 store owners or managers indicated that their store had a policy regulating the display of tobacco ads and tobacco product displays.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1910192

  8. Circadian blood pressure variability in type 1 diabetes subjects and their nondiabetic siblings - influence of erythrocyte electron transfer.

    Science.gov (United States)

    Matteucci, Elena; Consani, Cristina; Masoni, Maria Chiara; Giampietro, Ottavio

    2010-10-05

    Normotensive non-diabetic relatives of type 1 diabetes (T1D) patients have an abnormal blood pressure response to exercise testing that is associated with indices of metabolic syndrome and increased oxidative stress. The primary aim of this study was to investigate the circadian variability of blood pressure and the ambulatory arterial stiffness index (AASI) in healthy siblings of T1D patients vs healthy control subjects who had no first-degree relative with T1D. Secondary aims of the study were to explore the influence of both cardiovascular autonomic function and erythrocyte electron transfer activity as oxidative marker on the ambulatory blood pressure profile. Twenty-four hour ambulatory blood pressure monitoring (ABPM) was undertaken in 25 controls, 20 T1D patients and 20 siblings. In addition to laboratory examination (including homeostasis model assessment of insulin sensitivity) and clinical testing of autonomic function, we measured the rate of oxidant-induced erythrocyte electron transfer to extracellular ferricyanide (RBC vfcy). Systolic blood pressure (SBP) midline-estimating statistic of rhythm and pulse pressure were higher in T1D patients and correlated positively with diabetes duration and RBC vfcy; autonomic dysfunction was associated with diastolic BP ecphasia and increased AASI. Siblings had higher BMI, lower insulin sensitivity, larger SBP amplitude, and higher AASI than controls. Daytime SBP was positively, independently associated with BMI and RBC vfcy. Among non-diabetic people, there was a significant correlation between AASI and fasting plasma glucose. Siblings of T1D patients exhibited a cluster of sub-clinical metabolic abnormalities associated with consensual perturbations in BP variability. Moreover, our findings support, in a clinical setting, the proposed role of transplasma membrane electron transport systems in vascular pathobiology.

  9. Circadian blood pressure variability in type 1 diabetes subjects and their nondiabetic siblings - influence of erythrocyte electron transfer

    Directory of Open Access Journals (Sweden)

    Masoni Maria

    2010-10-01

    Full Text Available Abstract Background Normotensive non-diabetic relatives of type 1 diabetes (T1D patients have an abnormal blood pressure response to exercise testing that is associated with indices of metabolic syndrome and increased oxidative stress. The primary aim of this study was to investigate the circadian variability of blood pressure and the ambulatory arterial stiffness index (AASI in healthy siblings of T1D patients vs healthy control subjects who had no first-degree relative with T1D. Secondary aims of the study were to explore the influence of both cardiovascular autonomic function and erythrocyte electron transfer activity as oxidative marker on the ambulatory blood pressure profile. Methods Twenty-four hour ambulatory blood pressure monitoring (ABPM was undertaken in 25 controls, 20 T1D patients and 20 siblings. In addition to laboratory examination (including homeostasis model assessment of insulin sensitivity and clinical testing of autonomic function, we measured the rate of oxidant-induced erythrocyte electron transfer to extracellular ferricyanide (RBC vfcy. Results Systolic blood pressure (SBP midline-estimating statistic of rhythm and pulse pressure were higher in T1D patients and correlated positively with diabetes duration and RBC vfcy; autonomic dysfunction was associated with diastolic BP ecphasia and increased AASI. Siblings had higher BMI, lower insulin sensitivity, larger SBP amplitude, and higher AASI than controls. Daytime SBP was positively, independently associated with BMI and RBC vfcy. Among non-diabetic people, there was a significant correlation between AASI and fasting plasma glucose. Conclusions Siblings of T1D patients exhibited a cluster of sub-clinical metabolic abnormalities associated with consensual perturbations in BP variability. Moreover, our findings support, in a clinical setting, the proposed role of transplasma membrane electron transport systems in vascular pathobiology.

  10. Beyond Promotion-Based Store Switching: Antecedents and Consequences of Systematic Multiple-Store Shopping

    OpenAIRE

    Gijsbrechts, E.; Campo, K.; Nisol, P.

    2005-01-01

    In this paper, we demonstrate that single-purpose multiple store shopping is not only driven by opportunistic, promotion-based motivations, but may also be part of a longer term shopping planning process based on stable store characteristics.Starting from a utility-maximizing shopping behavior model, we find that consumers systematically visit multiple stores to take advantage of two types of store complementarity.With 'fixed cost complementarity', consumers alternate visits to highly preferr...

  11. Why an alternative to blood transfusion?

    Science.gov (United States)

    Shander, Aryeh; Goodnough, Lawrence Tim

    2009-04-01

    Allogeneic blood transfusions have been associated with several risks and complications and with worse outcomes in a substantial number of patient populations and clinical scenarios. Allogeneic blood is costly and difficult to procure, transport, and store. Global and local shortages are imminent. Alternatives to transfusion provide many advantages, and their use is likely to improve outcomes as safer and more effective agents are developed.

  12. NACS Store Planning Manual.

    Science.gov (United States)

    College Store Journal, 1979

    1979-01-01

    Topics discussed by the NACS Store Planning/Renovation Committees in this updated version of the college store renovation manual include: short- and long-range planning, financial considerations, professional planning assistance, the store's image and business character, location considerations, building requirements, space requirements, fixtures,…

  13. Low iron stores are related to higher blood concentrations of manganese, cobalt and cadmium in non-smoking, Norwegian women in the HUNT 2 study

    Energy Technology Data Exchange (ETDEWEB)

    Margrete Meltzer, Helle, E-mail: helle.margrete.meltzer@fhi.no [Division of Environmental Medicine, Department of Food Safety and Nutrition, Norwegian Institute of Public Health, PO Box 4404 Nydalen, N-0403 Oslo (Norway); Lise Brantsaeter, Anne [Division of Environmental Medicine, Department of Food Safety and Nutrition, Norwegian Institute of Public Health, PO Box 4404 Nydalen, N-0403 Oslo (Norway); Borch-Iohnsen, Berit [Institute of Basic Medical Sciences, Department of Nutrition, University of Oslo, PO Box 1046 Blindern, N-0316 Oslo (Norway); Ellingsen, Dag G. [National Institute of Occupational Health, PO Box 8149 Dep, N-0033 Oslo (Norway); Alexander, Jan [Division of Environmental Medicine, Department of Food Safety and Nutrition, Norwegian Institute of Public Health, PO Box 4404 Nydalen, N-0403 Oslo (Norway); Thomassen, Yngvar [National Institute of Occupational Health, PO Box 8149 Dep, N-0033 Oslo (Norway); Stigum, Hein [Division of Epidemiology, Department of Chronic Diseases, Norwegian Institute of Public Health, PO Box 4404 Nydalen, N-0403 Oslo (Norway); Ydersbond, Trond A. [Statistics Norway, P.Box 8131 Dep, N-0033 Oslo (Norway)

    2010-07-15

    Low iron (Fe) stores may influence absorption or transport of divalent metals in blood. To obtain more knowledge about such associations, the divalent metal ions cadmium (Cd), manganese (Mn), cobalt (Co), copper (Cu), zinc (Zn) and lead (Pb) and parameters of Fe metabolism (serum ferritin, haemoglobin (Hb) and transferrin) were investigated in 448 healthy, menstruating non-smoking women, age 20-55 years (mean 38 years), participating in the Norwegian HUNT 2 study. The study population was stratified for serum ferritin: 257 were iron-depleted (serum ferritin <12 {mu}g/L) and 84 had iron deficiency anaemia (serum ferritin <12 {mu}g/L and Hb<120 g/L). The low ferritin group had increased blood concentrations of Mn, Co and Cd but normal concentrations of Cu, Zn and Pb. In multiple regression models, ferritin emerged as the main determinant of Mn, Co and Cd (p<0.001), while no significant associations with Cu, Zn and Pb were found. Adjusted r{sup 2} for the models were 0.28, 0.48 and 0.34, respectively. Strong positive associations between blood concentrations of Mn, Co and Cd were observed, also when controlled for their common association with ferritin. Apart from these associations, the models showed no significant interactions between the six divalent metals studied. Very mild anaemia (110{<=}Hb<120 g/L) did not seem to have any effect independent of low ferritin. Approximately 26% of the women with iron deficiency anaemia had high concentrations of all of Mn, Co and Cd as opposed to 2.3% of iron-replete subjects. The results confirm that low serum ferritin may have an impact on body kinetics of certain divalent metal ions, but not all. Only a fraction of women with low iron status exhibited an increased blood concentration of divalent metals, providing indication of complexities in the body's handling of these metals.

  14. HOW IN-STORE MARKETING AFFECTS PURCHASE AND SALESMAN’S RECOMMENDATION RATE IN TELECOM RETAIL STORES

    Directory of Open Access Journals (Sweden)

    Melik Karabıyıkoglu

    2013-01-01

    Full Text Available The authors study in-store marketing for telecom retail stores in GSM sector in Turkey which handset manufacturers practice special application in stores for increasing purchasing and improving suggestion rates of their products. They develop a theoretical model of dealers, and manufacturers behavior based on observations about key aspects of the mobile phone market. The analysis provides important insights about in-store marketing and their applications. For example, owner of the store and salesmen would like to support in-store marketing applications of manufacturers in spite of operators’s in-store rules. The authors find empirical support when they test the theoretical results.

  15. A simple assay of paracetamol based on dried blood

    African Journals Online (AJOL)

    User

    Dried blood spots in Guthrie cards are a reliable means of blood sampling suitable for pharmacoki- netic analysis in .... pers were then packed in plastic bags and stored at. 4ºC in the ..... of paracetamol and its metabolites in urine, plasma and ...

  16. Immunomodulating effect of blood transfusion: is storage time important?

    DEFF Research Database (Denmark)

    Mynster, T; Dybkjoer, E; Kronborg, Gitte

    1998-01-01

    OBJECTIVES: TNF-alpha and IL-2 are important cytokines in macrophage and T-lymphocyte activity against infection and dissemination of malignant cells. We studied the influence of supernatants from stored whole blood and buffy-coat-depleted SAGM (saline, adenine, glucose and mannitol) blood in sti...

  17. Predictors of iron levels in 14,737 Danish blood donors

    DEFF Research Database (Denmark)

    Rigas, Andreas Stribolt; Sørensen, Cecilie Juul; Pedersen, Ole Birger

    2014-01-01

    BACKGROUND: Dietary studies show a relationship between the intake of iron enhancers and inhibitors and iron stores in the general population. However, the impact of dietary factors on the iron stores of blood donors, whose iron status is affected by blood donations, is incompletely understood....... STUDY DESIGN AND METHODS: In the Danish Blood Donor Study, we assessed the effect of blood donation frequency, physiologic factors, lifestyle and supplemental factors, and dietary factors on ferritin levels. We used multiple linear and logistic regression analyses stratified by sex and menopausal status....... RESULTS: Among high-frequency donors (more than nine donations in the past 3 years), we found iron deficiency (ferritin below 15 ng/mL) in 9, 39, and 22% of men, premenopausal women, and postmenopausal women, respectively. The strongest predictors of iron deficiency were sex, menopausal status, the number...

  18. Quality of intraoperative autologous blood withdrawal used for retransfusion after cardiopulmonary bypass.

    Science.gov (United States)

    Flom-Halvorsen, Hanne I; Øvrum, Eivind; Øystese, Rolf; Brosstad, Frank

    2003-09-01

    Intraoperative autologous blood withdrawal protects the pooled blood from the deleterious effects of cardiopulmonary bypass. Following reinfusion after cardiopulmonary bypass, the fresh autologous blood contributes to less coagulation abnormalities and reduces postoperative bleeding and the need for allogeneic blood products. However, few data have been available concerning the quality and potential activation of fresh blood stored at room temperature in the operating room. Forty coronary artery bypass grafting patients undergoing a consistent intraoperative and postoperative autotransfusion protocol had a median of 1,000 mL of autologous blood withdrawn before cardiopulmonary bypass. After heparinization the blood was drained from the venous catheter via venous cannula into standard blood bags and stored in the operating room until termination of cardiopulmonary bypass. Samples for hemostatic and inflammatory markers were taken from the pooled blood immediately before it was returned to the patient. There was some activation of platelets in the stored autologous blood, as measured by an increase of beta-thromboglobulin. Indications of thrombin formation, as assessed by plasma levels of thrombin-antithrombin complex and prothrombin fragment 1.2 were not seen, and there was no fibrinolytic activity. The red blood cells remained intact, indicated by the absence of plasma free hemoglobin. As for the inflammatory response, the levels of the terminal complement complex remained stable, and the cytokines tumor necrosis factor-alpha and interleukin 6 levels were not increased during storage. The complement activation products increased minimally, but remained within normal ranges. Except for slight activation of platelets, there was no indication of coagulation, hemolysis, fibrinolysis, or immunologic activity in the autologous blood after approximately 1 hour of operating room storage. The autologous blood was preserved in a condition of high quality, and retransfusion

  19. Distributed energy store railgun

    International Nuclear Information System (INIS)

    Marshall, R.A.

    1991-01-01

    This paper reports that when the limiting case of a distributed energy store railgun is analyzed, i.e., the case where the space between adjacent energy stores become indefinitely small, three important results are obtained. First, the shape of the current pulse delivered by each store is sinusoidal and an exponential tail. Second, the rail-to-rail voltage behind the rear-most active store approaches zero. Third, it is not possible to choose parameters in such a way that capacitor crowbars can be eliminated

  20. Information for stores users

    CERN Multimedia

    Logistics Group - FI Department

    2005-01-01

    The Farnell catalogue can now be accessed from the Material Request form on EDH in addition to the CERN Stores catalogue. Users can order Farnell equipment as well as standard Stores equipment at the same time using a single document, the EDH Materials Request form. The Materials Request form offers users items from both the internal 'Stores' catalogue and the external 'Farnell' catalogue, all of which may be ordered on the same form. The system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Farnell equipment to Farnell. The delivery time is 48 hours in both cases. Requests for materials are routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  1. Biochemically verified smoking cessation and vaping beliefs among vape store customers.

    Science.gov (United States)

    Tackett, Alayna P; Lechner, William V; Meier, Ellen; Grant, DeMond M; Driskill, Leslie M; Tahirkheli, Noor N; Wagener, Theodore L

    2015-05-01

    To evaluate biochemically verified smoking status and electronic nicotine delivery systems (ENDS) use behaviors and beliefs among a sample of customers from vapor stores (stores specializing in ENDS). A cross-sectional survey of 215 adult vapor store customers at four retail locations in the Midwestern United States; a subset of participants (n = 181) also completed exhaled carbon monoxide (CO) testing to verify smoking status. Outcomes evaluated included ENDS preferences, harm beliefs, use behaviors, smoking history and current biochemically verified smoking status. Most customers reported starting ENDS as a means of smoking cessation (86%), using newer-generation devices (89%), vaping non-tobacco/non-menthol flavors (72%) and using e-liquid with nicotine strengths of ≤20 mg/ml (72%). There was a high rate of switching (91.4%) to newer-generation ENDS among those who started with a first-generation product. Exhaled CO readings confirmed that 66% of the tested sample had quit smoking. Among those who continued to smoke, mean cigarettes per day decreased from 22.1 to 7.5 (P customers in the United States who use electronic nicotine delivery devices to stop smoking, vaping longer, using newer-generation devices and using non-tobacco and non-menthol flavored e-liquid appear to be associated with higher rates of smoking cessation. © 2015 Society for the Study of Addiction.

  2. Building Store Satisfaction Centred on Customer Retention in Clothing Retailing: Store Design and Ease of Shopping

    Directory of Open Access Journals (Sweden)

    Gulden Turhan

    2016-01-01

    Full Text Available The study’s research model suggests that store design and ease of shopping are associated with customer retention through a mediated pathway in which store design and ease of shopping influence perceived store satisfaction, which in turn, influences customer retention. This survey was administered to two separate clothing stores offered to either females or males (in total, 533 participants. Using structural equation modelling methodology, data was analysed to explain the interrelations among the variables in the model. The results of an empirical study of a sample of store shoppers revealed that store design and ease of shopping influence customer retention in an indirect way through customer perception of satisfaction with the store. In building store satisfaction that is centred on customer retention, store design and shopping ease differ in their relative influences. This difference is high for females, but for men as low as to be considered negligible in males. As a result, improving customers’ perceptions of store design and ease of shopping is a way to ensure store satisfaction support customer retention. The results of the study provide a new insight into the relationships by suggesting indirect effects of shopping ease and store design on consumer retention by their impacts on store satisfaction, rather than direct effects.

  3. Building Store Satisfaction Centred on Customer Retention in Clothing Retailing: Store Design and Ease of Shopping

    Directory of Open Access Journals (Sweden)

    Gulden Turhan

    2014-01-01

    Full Text Available The study’s research model suggests that store design and ease of shopping are associated with customer retention through a mediated pathway in which store design and ease of shopping influence perceived store satisfaction, which in turn, influences customer retention. This survey was administered to two separate clothing stores offered to either females or males (in total, 533 participants. Using structural equation modelling methodology, data was analysed to explain the interrelations among the variables in the model. The results of an empirical study of a sample of store shoppers revealed that store design and ease of shopping influence customer retention in an indirect way through customer perception of satisfaction with the store. In building store satisfaction that is centred on customer retention, store design and shopping ease differ in their relative influences. This difference is high for females, but for men as low as to be considered negligible in males. As a result, improving customers’ perceptions of store design and ease of shopping is a way to ensure store satisfaction support customer retention. The results of the study provide a new insight into the relationships by suggesting indirect effects of shopping ease and store design on consumer retention by their impacts on store satisfaction, rather than direct effects.

  4. TruStore: Implementing a Trusted Store for Android

    OpenAIRE

    Yury, Zhauniarovich; Olga, Gadyatskaya; Bruno, Crispo

    2013-01-01

    In the Android ecosystem, the process of verifying the integrity of downloaded apps is left to the user. Different from other systems, e.g., Apple, App Store, Google does not provide any certified vetting process for the Android apps. This choice has a lot of advantages but it is also the open door to possible attacks as the recent one shown by Bluebox. To address this issue, we present how to enable the deployment of application certification service, we called TruStores, for the Android pla...

  5. Vapor Store Owner Beliefs and Messages to Customers.

    Science.gov (United States)

    Cheney, Marshall K; Gowin, Mary; Wann, Taylor Franklin

    2016-05-01

    Electronic cigarette (e-cigarette) use is becoming increasingly popular but little is known about the role of the local vapor store in promoting use and influencing customer attitudes and beliefs about vaping. Thirty-three vapor store owners were interviewed about their personal beliefs and attitudes about e-cigarettes and what they told customers about the health impact of using e-cigarettes. Interviews were recorded then transcribed, coded, and analyzed for themes. Vapor store owners used the internet to obtain information about vaping, most often from YouTube and industry sources. Owners often did not have the training to critically evaluate research studies posted on the internet. Owners promoted vaping as a healthier alternative to smoking and often compared it to a medical treatment. Owners considered ingredients in the e-liquid as safe to use if it was safe to eat and discussed other foods vapor ingredients were found in. Owners also discussed the safety of secondhand vapor. Owners described the health impact of nicotine in e-liquid by comparing nicotine to caffeine and promoted the nicotine in e-liquid as coming from vegetables rather than tobacco. Finally, owners talked about vaping as a habit rather than a continued addiction to nicotine. Local store owners are an important source of health information for current and potential e-cigarette users but their messages to customers may be based on incomplete or misinterpreted information. Understanding local store owner messages to customers in addition to internet-based messages is an important area for future public health research. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Influence of different storage times and temperatures on blood gas ...

    African Journals Online (AJOL)

    The present study was designed to investigate the effects of storage temperature and time on blood gas and acid-base balance of ovine venous blood. Ten clinically healthy sheep were used in this study. A total number of 30 blood samples, were divided into three different groups, and were stored in a refrigerator adjusted ...

  7. Acute effects of electronic and tobacco cigarette smoking on complete blood count.

    Science.gov (United States)

    Flouris, Andreas D; Poulianiti, Konstantina P; Chorti, Maria S; Jamurtas, Athanasios Z; Kouretas, Dimitrios; Owolabi, Emmanuel O; Tzatzarakis, Manolis N; Tsatsakis, Aristidis M; Koutedakis, Yiannis

    2012-10-01

    The World Health Organisation called for research assessing the safety of electronic cigarette (e-cigarette). We evaluated the acute effect of active and passive e-cigarette and tobacco cigarette smoking on complete blood count (CBC) markers in 15 smokers and 15 never-smokers, respectively. Smokers underwent a control session, an active tobacco cigarette smoking session, and an active e-cigarette smoking session. Never-smokers underwent a control session, a passive tobacco cigarette smoking session, and a passive e-cigarette smoking session. The results demonstrated that CBC indices remained unchanged during the control session and the active and passive e-cigarette smoking sessions (P>0.05). Active and passive tobacco cigarette smoking increased white blood cell, lymphocyte, and granulocyte counts for at least one hour in smokers and never smokers (Pissues and other areas of consumer product safety of e-cigarettes, because the nicotine content in the liquids used may vary considerably. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Electronic Commerce: Theory and Practice

    OpenAIRE

    Išoraitė, Margarita; Miniotienė, Neringa

    2018-01-01

    Electronic commerce in the world is becoming an increasingly popular form of trade. Most shoppers start looking for products, descriptions and quality features online before buying a product. In order to provide customers with more convenience, more and more companies and existing stores are setting up their own online stores where a person can buy at a convenient time, even at night when regular stores are no longer working. Online stores allow you to save time spent by a person searching fo...

  9. Controlled lecithin release from a hierarchical architecture on blood-contacting surface to reduce hemolysis of stored red blood cells.

    Science.gov (United States)

    Shi, Qiang; Fan, Qunfu; Ye, Wei; Hou, Jianwen; Wong, Shing-Chung; Xu, Xiaodong; Yin, Jinghua

    2014-06-25

    Hemolysis of red blood cells (RBCs) caused by implant devices in vivo and nonpolyvinyl chloride containers for RBC preservation in vitro has recently gained much attention. To develop blood-contacting biomaterials with long-term antihemolysis capability, we present a facile method to construct a hydrophilic, 3D hierarchical architecture on the surface of styrene-b-(ethylene-co-butylene)-b-styrene elastomer (SEBS) with poly(ethylene oxide) (PEO)/lecithin nano/microfibers. The strategy is based on electrospinning of PEO/lecithin fibers onto the surface of poly [poly(ethylene glycol) methyl ether methacrylate] [P(PEGMEMA)]-modified SEBS, which renders SEBS suitable for RBC storage in vitro. We demonstrate that the constructed 3D architecture is composed of hydrophilic micro- and nanofibers, which transforms to hydrogel networks immediately in blood; the controlled release of lecithin is achieved by gradual dissolution of PEO/lecithin hydrogels, and the interaction of lecithin with RBCs maintains the membrane flexibility and normal RBC shape. Thus, the blood-contacting surface reduces both mechanical and oxidative damage to RBC membranes, resulting in low hemolysis of preserved RBCs. This work not only paves new way to fabricate high hemocompatible biomaterials for RBC storage in vitro, but provides basic principles to design and develop antihemolysis biomaterials for implantation in vivo.

  10. Model/School Store Management Guide.

    Science.gov (United States)

    North Dakota State Board for Vocational Education, Bismarck.

    This teacher-coordinator manual assists in planning, organizing, directing, and evaluating student learning experiences associated with either a model store, school store, or combination. (A model store in a marketing laboratory simulates marketing functions; the school store markets merchandise to fellow students, faculty, and/or the public.)…

  11. Wireless connection of continuous glucose monitoring system to the electronic patient record

    Science.gov (United States)

    Murakami, Alexandre; Gutierrez, Marco A.; Lage, Silvia G.; Rebelo, Marina S.; Granja, Luiz A. R.; Ramires, Jose A. F.

    2005-04-01

    The control of blood sugar level (BSL) at near-normal levels has been documented to reduce both acute and chronic complications of diabetes mellitus. Recent studies suggested, the reduction of mortality in a surgical intensive care unit (ICU), when the BSL are maintained at normal levels. Despite of the benefits appointed by these and others clinical studies, the strict BSL control in critically ill patients suffers from some difficulties: a) medical staff need to measure and control the patient"s BSL using blood sample at least every hour. This is a complex and time consuming task; b) the inaccuracy of standard capillary glucose monitoring (fingerstick) in hypotensive patients and, if frequently used to sample arterial or venous blood, may lead to excess phlebotomy; c) there is no validated procedure for continuously monitoring of BSL levels. This study used the MiniMed CGMS in ill patients at ICU to send, in real-time, BSL values to a Web-Based Electronic Patient Record. The BSL values are parsed and delivered through a wireless network as an HL7 message. The HL7 messages with BSL values are collected, stored into the Electronic Patient Record and presented into a bed-side monitor at the ICU together with other relevant patient information.

  12. How the Measurement of Store Choice Behaviour Moderates the Relationship between Distance and Store Choice Behaviour

    DEFF Research Database (Denmark)

    Hansen, Torben; Cumberland, Flemming; Solgaard, Hans Stubbe

    2013-01-01

    The influence of distance on consumer store choice behaviour has been considered in many studies. In that respect, frequency and budget share are frequently used methods of measurement to determine the consumer's store choice behavour. In this study, we propose that the significance of distance...... is influenced by the way in which store choice behaviour is conceptualized. A survey among 631 consuemrs was performed in order to examine the research proposition. Structural equation results suggest that the negative effect of distance on store choice behaviour is larger when store choice behaviour...... is measured as number of visits to a particular store than wehen store cjoice behaviour is measured as the percentage of budget spend at a particular store. Our results indicate that researchers should carefully consider the measurement of store choice behaviour when carrying out empirical research invlving...

  13. Storing up trouble

    International Nuclear Information System (INIS)

    Townsley, M.

    1992-01-01

    Scottish Nuclear have applied for permission to build a temporary ground-level dry store for spent fuel at Torness. However, Nirex's failure to find a suitable site for a long-term repository could mean that the Torness store will be less temporary than planned. (author)

  14. Feasibility of trialling cord blood stem cell treatments for cerebral palsy in Australia.

    Science.gov (United States)

    Crompton, Kylie E; Elwood, Ngaire; Kirkland, Mark; Clark, Pamela; Novak, Iona; Reddihough, Dinah

    2014-07-01

    Umbilical cord blood may have therapeutic benefit in children with cerebral palsy (CP), but further studies are required. On first appearance it seems that Australia is well placed for such a trial because we have excellence in CP research backed by extensive CP registers, and both public and private cord blood banks. We aimed to examine the possibilities of conducting a trial of autologous umbilical cord blood cells (UCBCs) as a treatment for children with CP in Australia. Data linkages between CP registers and cord blood banks were used to estimate potential participant numbers for a trial of autologous UCBCs for children with CP. As of early 2013, one Victorian child with CP had cord blood stored in the public bank, and between 1 and 3 children had their cord blood stored at Cell Care Australia (private cord blood bank). In New South Wales, we counted two children on the CP register who had their stored cord blood available in early 2013. We estimate that there are between 10 and 24 children with CP of any type who have autologous cord blood available across Australia. In nations with small populations like Australia, combined with Australia's relatively low per capita cord blood storage to date, it is not currently feasible to conduct trials of autologous UCBCs for children with CP. Other options must be explored, such as allogeneic UCBCs or prospective trials for neonates at risk of CP. © 2014 The Authors. Journal of Paediatrics and Child Health © 2014 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  15. Store operations to maintain cache coherence

    Energy Technology Data Exchange (ETDEWEB)

    Evangelinos, Constantinos; Nair, Ravi; Ohmacht, Martin

    2017-08-01

    In one embodiment, a computer-implemented method includes encountering a store operation during a compile-time of a program, where the store operation is applicable to a memory line. It is determined, by a computer processor, that no cache coherence action is necessary for the store operation. A store-without-coherence-action instruction is generated for the store operation, responsive to determining that no cache coherence action is necessary. The store-without-coherence-action instruction specifies that the store operation is to be performed without a cache coherence action, and cache coherence is maintained upon execution of the store-without-coherence-action instruction.

  16. Store operations to maintain cache coherence

    Energy Technology Data Exchange (ETDEWEB)

    Evangelinos, Constantinos; Nair, Ravi; Ohmacht, Martin

    2017-09-12

    In one embodiment, a computer-implemented method includes encountering a store operation during a compile-time of a program, where the store operation is applicable to a memory line. It is determined, by a computer processor, that no cache coherence action is necessary for the store operation. A store-without-coherence-action instruction is generated for the store operation, responsive to determining that no cache coherence action is necessary. The store-without-coherence-action instruction specifies that the store operation is to be performed without a cache coherence action, and cache coherence is maintained upon execution of the store-without-coherence-action instruction.

  17. Mechanisms of pancreatic islet cell destruction. Dose-dependent cytotoxic effect of soluble blood mononuclear cell mediators on isolated islets of Langerhans

    DEFF Research Database (Denmark)

    Mandrup-Poulsen, T; Bendtzen, K; Nerup, J

    1986-01-01

    Supernatants of peripheral blood mononuclear cells from healthy human donors stimulated with recall antigen (purified protein derivative of tuberculin) or lectin (phytohaemagglutinin) markedly inhibited the insulin release from isolated human and rat islets of Langerhans, and decreased rat islet...... reconstituted with tuberculin or phytohaemagglutinin did not impair islet function. Electron microscopy demonstrated that supernatants were cytotoxic to islet cells. The cytotoxic mononuclear cell mediator(s) was non-dialysable, sensitive to heating to 56 degrees C, labile even when stored at -70 degrees C...

  18. High-affinity hemoglobin and blood oxygen saturation in diving emperor penguins.

    Science.gov (United States)

    Meir, Jessica U; Ponganis, Paul J

    2009-10-01

    The emperor penguin (Aptenodytes forsteri) thrives in the Antarctic underwater environment, diving to depths greater than 500 m and for durations longer than 23 min. To examine mechanisms underlying the exceptional diving ability of this species and further describe blood oxygen (O2) transport and depletion while diving, we characterized the O2-hemoglobin (Hb) dissociation curve of the emperor penguin in whole blood. This allowed us to (1) investigate the biochemical adaptation of Hb in this species, and (2) address blood O2 depletion during diving, by applying the dissociation curve to previously collected partial pressure of O2 (PO2) profiles to estimate in vivo Hb saturation (SO2) changes during dives. This investigation revealed enhanced Hb-O2 affinity (P50=28 mmHg, pH 7.5) in the emperor penguin, similar to high-altitude birds and other penguin species. This allows for increased O2 at low blood PO2 levels during diving and more complete depletion of the respiratory O2 store. SO2 profiles during diving demonstrated that arterial SO2 levels are maintained near 100% throughout much of the dive, not decreasing significantly until the final ascent phase. End-of-dive venous SO2 values were widely distributed and optimization of the venous blood O2 store resulted from arterialization and near complete depletion of venous blood O2 during longer dives. The estimated contribution of the blood O2 store to diving metabolic rate was low and highly variable. This pattern is due, in part, to the influx of O2 from the lungs into the blood during diving, and variable rates of tissue O2 uptake.

  19. Information for Stores Users

    CERN Multimedia

    Logistics Group

    2004-01-01

    As the FARNELL Catalogue CAPACITORS, RESISTORS and POTENTIOMETERS have now been integrated into the CERN Stores Catalogue (SCEM Groups 10 and 11) they can now be obtained via an EDH 'Material Request' like any other Stores item. N.B. The Farnell 'Order code' is one of the key-words that make it easier to find items in the Stores Catalogue. Logistics Group FI Department

  20. Inflammable materials stores

    International Nuclear Information System (INIS)

    Nandagopan, V.

    2017-01-01

    A new Inflammable Materials Stores has been constructed by A and SED, BARC near Gamma Field for storage of inflammable materials falling into Petroleum Class ‘A’ ‘B’ and “C” mainly comprising of oils and lubricants, Chemicals like Acetone, Petroleum Ether etc. which are regularly procured by Central Stores Unit (CSU) for issue to the various divisions of BARC. The design of the shed done by A and SED, BARC was duly got approved from Petroleum and Explosive Safety Organization (PESO) which is a mandatory requirement before commencement of the construction. The design had taken into account various safety factors which is ideally required for an inflammable materials stores

  1. Photoinduced discharge of electrons stored in a TiO2-MWCNT composite to an analyte: application to the fluorometric determination of hydrogen peroxide, glucose and aflatoxin B1.

    Science.gov (United States)

    Rhouati, Amina; Nasir, Muhammad; Marty, Jean-Louis; Hayat, Akhtar

    2017-12-06

    The authors describe an analytical detection scheme based on the use of multiwalled carbon nanotubes (MWCNTs) that accept and store electrons upon contact with photo-irradiated TiO 2 nanoparticles (TiO 2 -NPs). The Fermi level equilibration with photo-irradiated TiO 2 -NPs has a storage value of 0.35 mM of electrons per 120 mg·L -1 of MWCNTs. The stored electrons can be discharged on demand upon addition of electron acceptors to the TiO 2 -NP/MWCNT composite. These findings are applied to detect the quencher hydrogen peroxide. H 2 O 2 also is produced on enzymatic action of glucose oxidase on glucose, and this enables glucose also to be quantified by using the TiO 2 -NP/MWCNT fluorescent nanoprobe. The wide scope of the method also is demonstrated by an assay for aflatoxin B1 that is making use of an FAM-labeled aptamer where the FAM fluorophore on the aptamer quenches the emission of the nanoprobe. The following analytical linear ranges and limits of detection are found: H 2 O 2 : 0.1-100 μM and 15 nM; glucose: 5-200 μM and 0.5 μM; aflatoxin: 0.1-40 ng·mL -1 and 0.02 ng·mL -1 . The method was applied to the determination of glucose in human serum. Graphical abstract The assays demonstrated in (b) and (c) are based on the fluorescence quenching ability of MWCNTs-TiO 2 . In the presence of the target (analyte), the fluorescence is restored and the target concentration is determined from the percentage of fluorescence recovery.

  2. Patient blood management -- the GP's guide.

    Science.gov (United States)

    Minck, Sandra; Robinson, Kathryn; Saxon, Ben; Spigiel, Tracey; Thomson, Amanda

    2013-05-01

    There is accumulating evidence of a strong association between blood transfusion and adverse patient outcomes. Patient blood management aims to achieve improved patient outcomes by avoiding unnecessary exposure to blood products through effective conservation and management of a patient's own blood. To introduce the general practitioner's role in patient blood management. There are a number of ways in which GPs can contribute to patient blood management, particularly in the care of patients scheduled for elective surgery. These include awareness, identification, investigation and management of patients with or at risk of anaemia; assessment of the adequacy of iron stores in patients undergoing planned procedures in which substantial blood loss is anticipated; awareness and assessment of medications and complementary medicines that might increase bleeding risk; and awareness of and ability to discuss with patients, the possible risks associated with blood transfusion and alternatives that may be available.

  3. Use of near infrared correlation spectroscopy for quantitation of surface iron, absorbed water and stored electronic energy in a suite of Mars soil analog materials

    Science.gov (United States)

    Coyne, Lelia M.; Banin, Amos; Carle, Glenn; Orenberg, James; Scattergood, Thomas

    1989-01-01

    A number of questions concerning the surface mineralogy and the history of water on Mars remain unresolved using the Viking analyses and Earth-based telescopic data. Identification and quantitation of iron-bearing clays on Mars would elucidate these outstanding issues. Near infrared correlation analysis, a method typically applied to qualitative and quantitative analysis of individual constituents of multicomponent mixtures, is adapted here to selection of distinctive features of a small, highly homologous series of Fe/Ca-exchanged montmorillonites and several kalinites. Independently determined measures of surface iron, relative humidity and stored electronic energy were used as constituent data for linear regression of the constituent vs. reflectance data throughout the spectral region 0.68 to 2.5 micrometers. High correlations were found in appropriate regions for all three constituents, though that with stored energy is still considered tenuous. Quantitation was improved using 1st and 2nd derivative spectra. High resolution data over a broad spectral range would be required to quantitatively identify iron-bearing clays by remotely sensed reflectance.

  4. Haematological changes in the blood of cultured Clarias gariepinus ...

    African Journals Online (AJOL)

    This study investigated the artifactual changes in the haematological values of Clarias gariepinus blood stored at room (32oC) and refrigerator (4oC) temperatures. Blood samples were collected from 12 apparently healthy fish weighing between 0.8 and 1kg. Samples were divided into two parts immediately after collection ...

  5. The effect of high energy electron irradiation on blood-brain barrier permeability to haloperidol and stobadin in rats

    Energy Technology Data Exchange (ETDEWEB)

    Trnovec, T; Kallay, Z [Komenskeho Univ., Bratislava (Czechoslovakia). Inst. of Preventive and Clinical Medicine; Volenec, K [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta; Bezek, S; Durisova, M; Scasnar, V; Kubu, M [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Ustav Experimentalnej Farmakologie; Svoboda, V [Medical Academy J.E. Purkyne, Hradec Kralove (Czechoslovakia)

    1991-10-01

    The heads of rats were irradiated by 4 MeV electrons in doses 90, 180, and 360 Gy. The observed times of deaths ranged 120-600, 60-420, and 150-370 min after 90, 180, and 360 Gy, respectively. A dose dependent decrease of the brain uptake index of haloperidol was observed 1 and 3 h post radiation. On the other hand an increased brain uptake index was found for stobadin after head irradiation with doses of 180 and 360 Gy. Regional cerebral blood flow, blood pressure, and heart rate were not significantly altered in the period following irradiation with 180 Gy. The observed changes in blood-brain barrier (BBB) permeability seem to be the result of the damaged function of morphological structures forming the BBB rather than altered regional blood flow. (orig.).

  6. The Nord interim store

    International Nuclear Information System (INIS)

    Leushacke, D.F.; Rittscher, D.

    1996-01-01

    In line with the decision taken in 1990 to shut down and decommission the Greifswald and Rheinsberg Nuclear Power Stations, the waste management concept of the Energiewerke Nord is based on direct and complete decommissioning of the six shut down reactor units within the next fifteen years. One key element of this concept is the construction and use of the Zwischenlager Nord (Nord Interim Store, ZLN) for holding the existing nuclear fuels and for interim and decay storage of the radioactive materials arising in decommissioning and demolition. The owner and operator of the store is Energiewerke Nord GmbH. The interim store has the functions of a processing and Energiewerke Nord GmbH. The interim store has the functions of a processing and treatment station and buffer store for the flows of residues arising. As a radioactive waste management station, it accommodates nuclear fuels, radioactive waste or residues which are not treated any further. It is used as a buffer store to allow the materials accumulating in disassembly to be stored temporarily before or after treatment in order to ensure continuous loading of the treatment plants. When operated as a processing station, the ZLN is able to handle nearly all types of radioactive waste and residues arising, except for nuclear fuels. These installations allow the treatment of radioactive residues to be separated from the demolition work both physically and in time. The possibilities of interium storage and buffer storage of untreated waste and waste packages make for high flexibility in logistics and waste management strategy. (orig.) [de

  7. A Comparison of Customer Relationships between Large Chain Stores and Small Local Stores in the Fashion Industry

    OpenAIRE

    Krstevska, Biljana

    2017-01-01

    This research investigates customer relationships of two distinct store formats (small local stores and large chain stores) in the fashion industry. The aim is to find out if there are differences between the store formats regarding customer relationships. Relationship marketing theory was used to formulate hypotheses. Shoppers of small local stores and large chain stores in Würzburg, Germany, were surveyed to test the hypotheses. Results indicate that customer relationships significantly dif...

  8. Information for stores users

    CERN Multimedia

    2006-01-01

    The Bossard catalogue is now accessible alongside the CERN Stores catalogue from the Material Request form on EDH. Users will thus be able to order Bossard equipment using the EDH Materials Request form. As a reminder, the system automatically forwards orders for standard Stores equipment to the CERN Stores and those for Bossard equipment to Bossard. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Some items will remain available from the emergency desk in the event of urgent requests. These items will be visible in the Stores catalogue even if they cannot be purchased via the EDH material request form. Logistics Group FI Department

  9. Family cord blood banking for sickle cell disease: a twenty-year experience in two dedicated public cord blood banks.

    Science.gov (United States)

    Rafii, Hanadi; Bernaudin, Françoise; Rouard, Helene; Vanneaux, Valérie; Ruggeri, Annalisa; Cavazzana, Marina; Gauthereau, Valerie; Stanislas, Aurélie; Benkerrou, Malika; De Montalembert, Mariane; Ferry, Christele; Girot, Robert; Arnaud, Cecile; Kamdem, Annie; Gour, Joelle; Touboul, Claudine; Cras, Audrey; Kuentz, Mathieu; Rieux, Claire; Volt, Fernanda; Cappelli, Barbara; Maio, Karina T; Paviglianiti, Annalisa; Kenzey, Chantal; Larghero, Jerome; Gluckman, Eliane

    2017-06-01

    Efforts to implement family cord blood banking have been developed in the past decades for siblings requiring stem cell transplantation for conditions such as sickle cell disease. However, public banks are faced with challenging decisions about the units to be stored, discarded, or used for other endeavors. We report here 20 years of experience in family cord blood banking for sickle cell disease in two dedicated public banks. Participants were pregnant women who had a previous child diagnosed with homozygous sickle cell disease. Participation was voluntary and free of charge. All mothers underwent mandatory serological screening. Cord blood units were collected in different hospitals, but processed and stored in two public banks. A total of 338 units were stored for 302 families. Median recipient age was six years (11 months-15 years). Median collected volume and total nucleated cell count were 91 mL (range 23-230) and 8.6×10 8 (range 0.7-75×10 8 ), respectively. Microbial contamination was observed in 3.5% (n=12), positive hepatitis B serology in 25% (n=84), and homozygous sickle cell disease in 11% (n=37) of the collections. Forty-four units were HLA-identical to the intended recipient, and 28 units were released for transplantation either alone (n=23) or in combination with the bone marrow from the same donor (n=5), reflecting a utilization rate of 8%. Engraftment rate was 96% with 100% survival. Family cord blood banking yields good quality units for sibling transplantation. More comprehensive banking based on close collaboration among banks, clinical and transplant teams is recommended to optimize the use of these units. Copyright© Ferrata Storti Foundation.

  10. Fate in humans of the plasticizer, DI (2-ethylhexyl) phthalate, arising from transfusion of platelets stored in vinyl plastic bags. [plasticizer migration into human blood from vinyl plastic bags during transfusion

    Science.gov (United States)

    Rubin, R. J.; Schiffer, C. A.

    1975-01-01

    Platelet concentrates were shown to contain 18-38 mg/100 ml of a phthalate plasticizer (DEHP) which arose by migration from the vinyl plastic packs in which the plateletes were prepared and stored. Transfusion of these platelets into 6 adult patients with leukemia resulted in peak blood plasma levels of DEHP ranging from 0.34 - 0.83 mg/100 ml. The blood levels fell mono-exponentially with a mean rate of 2.83 percent per minute and a half-life of 28.0 minutes. Urine was assayed by a method that would measure unchanged DEHP as well as all phthalic acid-containing metabolities. In two patients, at most 60 and 90% of the infused dose, respectively, was excreted in the urine collected for 24 hours post-transfusion. These estimates, however, could be high due to the simultaneous excretion of DEHP remaining from previous transfusions or arising from uncontrolled environmental exposures.

  11. Trans-membrane electron transfer in red blood cells immobilized in a chitosan film on a glassy carbon electrode

    International Nuclear Information System (INIS)

    Yu, Chunmei; Wang, Li; Zhu, Zhenkun; Bao, Ning; Gu, Haiying

    2014-01-01

    We have studied the trans-membrane electron transfer in human red blood cells (RBCs) immobilized in a chitosan film on a glassy carbon electrode (GCE). Electron transfer results from the presence of hemoglobin (Hb) in the RBCs. The electron transfer rate (k s ) of Hb in RBCs is 0.42 s −1 , and <1.13 s −1 for Hb directly immobilized in the chitosan film. Only Hb molecules in RBCs that are closest to the plasma membrane and the surface of the electrode can undergo electron transfer to the electrode. The immobilized RBCs displayed sensitive electrocatalytic response to oxygen and hydrogen peroxide. It is believed that this cellular biosensor is of potential significance in studies on the physiological status of RBCs based on observing their electron transfer on the modified electrode. (author)

  12. The influence of store image on customer satisfaction: a case study of a shoe store

    Directory of Open Access Journals (Sweden)

    Tarsis Souza Silva

    2010-01-01

    Full Text Available Knowledge of customers' image of a store is an essential factor in the management of retail outlets. This article presents a case study of the effect of the image customers have of a shoe store on their satisfaction, based on a descriptive and quantitative survey, with the application of a structured questionnaire. We then employed factor analysis to obtain seven store image factors: assortment, convenience, reputation, price, atmosphere, layout and service. The results show that the factor that most affects customer satisfaction in the store studied is service, and that atmosphere and layout have no effect in this respect. The results provide a better understanding of the role store image plays in customer satisfaction and loyalty.

  13. Buying in multiple stores : Shopping strategies beyond price promotions and their effects on Store Competition

    NARCIS (Netherlands)

    Gijsbrechts, E.; Campo, K.; Nisol, P.

    2013-01-01

    Grocery-store switching has typically been viewed as evidence of cherry-picking behavior, with consumers switching stores to benefit from temporary promotional offers. However, research reveals that it may also result from a longer-term planning process based on stable store characteristics. Even in

  14. Provenance Store Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Paulson, Patrick R.; Gibson, Tara D.; Schuchardt, Karen L.; Stephan, Eric G.

    2008-03-01

    Requirements for the provenance store and access API are developed. Existing RDF stores and APIs are evaluated against the requirements and performance benchmarks. The team’s conclusion is to use MySQL as a database backend, with a possible move to Oracle in the near-term future. Both Jena and Sesame’s APIs will be supported, but new code will use the Jena API

  15. Structural Changes in the Surface of Red Blood Cell Membranes during Long-Term Donor Blood Storage

    Directory of Open Access Journals (Sweden)

    V. V. Moroz

    2012-01-01

    Full Text Available Objective: to study changes in the surface of red blood cell membranes of donor blood at the macro- and ultrastructural level during its storage for 30 days and to evaluate the functional state of the red blood cell membrane during the whole storage period. Material and methods. The investigation was conducted on human whole blood and packed red blood cells placed in the specialized packs containing the preservative CPDA-1, by using calibrated electroporation and atomic force microscopy and measuring plasma pH. Conclusion. The long-term, up to 30-day, storage of whole blood and packed red blood cells at 4°C was attended by lower plasma pH and increased hemolysis rate constant during calibrated electroporation and by the development of oxidative processes. The hemolysis rate constant was also higher in the packed red blood cells than that in the whole blood. On days 5—6, the membrane structure showed defects that developed, as the blood was stored, and caused irreversible cell membrane damage by day 30. Key words: donor blood, red blood cell membranes, atomic force microscopy.

  16. Understanding Retailers’ Acceptance of Virtual Stores

    OpenAIRE

    Irene Y.L. Chen

    2010-01-01

    The acceptance of e-commerce among consumers has stimulated the rise of virtual stores. Increasing traditional retailers or people who do not have sufficient capital for maintaining a brick-and-mortar store have considered using virtual stores to reach global market. In the e-commerce literature, there has been rich research evidence concerning consumers’ acceptance of virtual stores. However, rigorous academic research on retailers’ acceptance of virtual stores is relatively scarce today. Th...

  17. Portable regional cerebral blood flow system based on IBM PC/AT and microprocessor electronics

    International Nuclear Information System (INIS)

    Mun, S.K.; Mun, I.K.; Petite, J.; Cohan, S.L.; Fahey, F.H.

    1986-01-01

    A portable 16-channel reginal cerebral blood flow (rCBF) measuring system has been developed using an IBM PC/AT and new microelectronics to improve processing speed and portability. The detector electronics were developed by Scan Detectronics A/S of Denmark. The counter module contains 18 16-bit counters, each programmable in four different modes. The rate meter has three independent microprocessor controllers for rate meter functions, window controller, and channel controller. The detector electronics and detection parameters can be fully controlled by the host PC/AT. The menu-driven system (Better Basic) assists the operator at each step. The collected data from 16 channels can be processed automatically or postprocessed using more flexible and sophisticated techniques within 20 minutes. The headgear holding 16 sodium iodide detectors is fabricated by modifying a motorcycle helmet

  18. Electron-ionic technology of storage of foodstuffs

    International Nuclear Information System (INIS)

    Tsoj, A.P.

    1996-01-01

    Work is trained on reduction of food suffer losses under cold store due to its drying and spoiling. Experimental cold store of fruits in 'microclimates' in electron-ionic medium created with help of pilot unit is carried out

  19. l-carnitine as a Potential Additive in Blood Storage Solutions: A Study on Erythrocytes

    OpenAIRE

    Soumya, R.; Carl, H.; Vani, R.

    2015-01-01

    Erythrocytes undergo various changes during storage (storage lesion) that in turn reduces their functioning and survival. Oxidative stress plays a major role in the storage lesion and antioxidants can be used to combat this stress. This study elucidates the effects of l-carnitine (LC) on erythrocytes of stored blood. Blood was obtained from male Wistar rats and stored (4 °C) for 20 days in CPDA-1 (citrate phosphate dextrose adenine) solution. Samples were divided into–(i) controls (ii) LC 10 ...

  20. Factors affecting the longevity of interim ILW stores, monitoring methods and techniques supporting store life extension - 59151

    International Nuclear Information System (INIS)

    Morris, Jenny; Wickham, Stephen; Hicks, Tim; Richardson, Phil; McKinney, James; Morris, Darrell; Brownridge, Melanie; Tearle, Mark

    2012-01-01

    Life-limiting features of stores (i.e. components of a typical Intermediate Level Waste (ILW) store that are vulnerable to failure) can be separated into those related to store design, the continuing operation of the store and equipment and store management. Environmental factors, including temperature, humidity, atmospheric pollutants and radiation fields also affect the longevity of ILW storage buildings and the integrity of the waste packages within the store. The current condition of the store and the causes and rates of any observed deterioration need to be determined to estimate the current operating life of the store and to analyse the costs and benefits associated with life extension. Suitable monitoring techniques and methods for extending the operating life of stores, either by remediation or replacement of identified life-limiting features, have also been assessed. Techniques including visual inspection (directly or by use of CCTV or inspection cells), corrosion coupons, crane monitoring and a wide range of indirect measurement methods can be used to monitor the condition of life-limiting features and the store environment. Methods for extending store life include the application of paint or coatings to retard degradation, use of electro-chemical treatments and repair of the concrete structure or replacement of components. Life-limiting features and environmental factors that affect the longevity of facilities for the interim storage of ILW have been identified through a literature review and Expert Workshop. Monitoring techniques are available for the key life-limiting feature of structural integrity of reinforced concrete, and for the atmospheric or surface concentration of corrosion-accelerating substances. Methods for remediating the reinforced concrete structure or crane rails to increase the expected lifetime of the store are also reviewed. Many of these techniques have previously been used at radioactive waste stores or other nuclear facilities in

  1. Information for stores users

    CERN Multimedia

    2006-01-01

    The Radiospares Catalogue is now accessible from the Material Request page on EDH in the same way as the CERN Stores Catalogue. This means that users can order Radiospares equipment by completing an EDH Materials Request form. N.B.: The system will automatically forward orders for standard Stores equipment to the CERN Stores and those for Radiospares equipment to Radiospares. In both cases the delivery time will be a maximum of 48 hours. Requests for materials will be routed for approval in accordance with the standard EDH routing procedures. Logistics Group FI Department

  2. INFORMATION FOR STORES USERS

    CERN Multimedia

    SPL Division

    1999-01-01

    You can now make Material Request from CERN Stores over the WEB :CERN Home/Administrative Tools/EDH/Material Requestor https://edh.cern.ch/Document/MAGVia the Stores Catalogue : CERN Home/Administrative Tools/Stores Catalogueor http://edhcat.cern.ch/In both cases, you need to enter your EDH login and password.For more details, you can consult the Quick Reference Guide on :http://edh.cern.ch/doc/quickrefguides.htmlor obtain a printed version from AIS Support at tel: 79933or e-mail to: ais.support@cern.chSPL DivisionLogistics Group

  3. Store-operate-coherence-on-value

    Science.gov (United States)

    Chen, Dong; Heidelberger, Philip; Kumar, Sameer; Ohmacht, Martin; Steinmacher-Burow, Burkhard

    2014-11-18

    A system, method and computer program product for performing various store-operate instructions in a parallel computing environment that includes a plurality of processors and at least one cache memory device. A queue in the system receives, from a processor, a store-operate instruction that specifies under which condition a cache coherence operation is to be invoked. A hardware unit in the system runs the received store-operate instruction. The hardware unit evaluates whether a result of the running the received store-operate instruction satisfies the condition. The hardware unit invokes a cache coherence operation on a cache memory address associated with the received store-operate instruction if the result satisfies the condition. Otherwise, the hardware unit does not invoke the cache coherence operation on the cache memory device.

  4. Restoration of blood 2,3-diphosphoglycerate levels in multi-transfused patients: effect of organic and inorganic phosphate.

    Science.gov (United States)

    Iapichino, G; Radrizzani, D; Solca, M; Franzosi, M G; Pallavicini, F B; Spina, G; Scherini, A

    1984-01-01

    Blood stored in acid-citrate-dextrose (ACD) shows a progressive decrease in 2,3-diphosphoglycerate (DPG) content. Since the decrease in DPG increases hemoglobin oxygen affinity, which in turn may reduce tissue and venous PO2 and peripheral oxygen delivery, many efforts have been made to preserve or restore DPG levels in stored blood. An in vivo rejuvenating technique, employing fructose-1,6-diphosphate (FDP) at a mean dosage of 1 mmol kg-1 day-1 of phosphate, to increase the DPG circulating level in multi-transfused patients is proposed. Eighteen patients, who received at least one-third of their estimated blood volume (3990 +/- 480 (SEM) ml of ACD stored blood) in blood transfusion, were treated: nine with inorganic phosphate, and nine with FDP. Basal DPG was very low in both groups: 12.61 +/- 1.34 (SEM) and 10.42 +/- 0.98 (SEM) mumol g-1, respectively (normal value is 14.5 mumol g-1, at pH 7.40). However, DPG values increased significantly and promptly in patients receiving FDP, whereas in cases of inorganic phosphate administration, it was not significantly raised over the basal value until the third day. Phosphatemia remained normal and constant with FDP, but it rose significantly on the third day of treatment with inorganic phosphate. FDP appears to consistently and rapidly increase DPG levels after transfusion with blood stored in ACD, and to be particularly safe.

  5. Differences in healthy food supply and stocking practices between small grocery stores, gas-marts, pharmacies and dollar stores.

    Science.gov (United States)

    Caspi, Caitlin Eicher; Pelletier, Jennifer E; Harnack, Lisa; Erickson, Darin J; Laska, Melissa N

    2016-02-01

    Little is known about the practices for stocking and procuring healthy food in non-traditional food retailers (e.g., gas-marts, pharmacies). The present study aimed to: (i) compare availability of healthy food items across small food store types; and (ii) examine owner/manager perceptions and stocking practices for healthy food across store types. Descriptive analyses were conducted among corner/small grocery stores, gas-marts, pharmacies and dollar stores. Data from store inventories were used to examine availability of twelve healthy food types and an overall healthy food supply score. Interviews with managers assessed stocking practices and profitability. Small stores in Minneapolis and St. Paul, MN, USA, not participating in the Special Supplemental Nutrition Program for Women, Infants, and Children. One hundred and nineteen small food retailers and seventy-one store managers. Availability of specific items varied across store type. Only corner/small grocery stores commonly sold fresh vegetables (63% v. 8% of gas-marts, 0% of dollar stores and 23% of pharmacies). More than half of managers stocking produce relied on cash-and-carry practices to stock fresh fruit (53%) and vegetables (55%), instead of direct store delivery. Most healthy foods were perceived by managers to have at least average profitability. Interventions to improve healthy food offerings in small stores should consider the diverse environments, stocking practices and supply mechanisms of small stores, particularly non-traditional food retailers. Improvements may require technical support, customer engagement and innovative distribution practices.

  6. Method for extending the useful shelf-life of refrigerated red blood cells by flushing with inert gas

    Science.gov (United States)

    Bitensky, M.W.; Yoshida, Tatsuro

    1997-04-29

    A method is disclosed using oxygen removal for extending the useful shelf-life of refrigerated red blood cells. A cost-effective, 4 C storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. Preservation of adenosine triphosphate levels and reduction in hemolysis and in membrane vesicle production of red blood cells stored at 4 C for prolonged periods of time is achieved by removing oxygen from the red blood cells at the time of storage; in particular, by flushing with an inert gas. Adenosine triphosphate levels of the stored red blood cells are boosted in some samples by addition of ammonium phosphate. 4 figs.

  7. CO2-dependent metabolic modulation in red blood cells stored under anaerobic conditions

    Science.gov (United States)

    Dumont, Larry J.; D'Alessandro, Angelo; Szczepiorkowski, Zbigniew M.; Yoshida, Tatsuro

    2015-01-01

    Background Anaerobic RBC storage reduces oxidative damage, maintains ATP & 2,3-diphosphoglycerate (DPG) levels and has superior 24hr recovery at 6weeks compared to standard storage. This study will determine if removal of CO2 during O2 depletion by gas exchange may affect RBC during anaerobic storage. Methods This is a matched 3 arm study (n=14): control, O2&CO2 depleted with Ar (AN), O2 depleted with 95%Ar/5%CO2 (AN[CO2]). RBC in additives AS-3 or OFAS3 were evenly divided into 3 bags, and anaerobic conditions were established by gas exchange. Bags were stored 1-6°C in closed chambers under anaerobic conditions or ambient air, sampled weekly for up to 9weeks for a panel of in vitro tests. A full metabolomics screening was conducted for the first 4 weeks of storage. Results Purging with Ar (AN) results in alkalization of the RBC and increased glucose consumption. The addition of 5%CO2 to the purging gas prevented CO2 loss with an equivalent starting and final pH and lactate to control bags (p>0.5, days0-21). ATP levels are higher in AN[CO2] (p<0.0001). DPG was maintained beyond 2 weeks in the AN arm (p<0.0001). Surprisingly, DPG was lost at the same rate in both control and AN[CO2] arms (p=0.6). Conclusion Maintenance of ATP in the AN[CO2] arm demonstrates that ATP production is not solely a function of the pH effect on glycolysis. CO2 in anaerobic storage prevented the maintenance of DPG, and DPG production appears to be pH dependent. CO2 as well as O2 depletion provides metabolic advantage for stored RBC. PMID:26477888

  8. Electron collisions and internal excitation in stored molecular ion beams

    International Nuclear Information System (INIS)

    Buhr, H.

    2006-01-01

    In storage ring experiments the role, which the initial internal excitation of a molecular ion can play in electron collisions, and the effect of these collisions on the internal excitation are investigated. Dissociative recombination (DR) and inelastic and super-elastic collisions are studied in the system of He + 2 . The DR rate coefficient at low energies depends strongly on the initial vibrational excitation in this system. Therefore changes in the DR rate coefficient are a very sensitive probe for changes in the vibrational excitation in He + 2 , which is used to investigate the effects of collisions with electrons and residual gas species. The low-energy DR of HD + is rich with resonances from the indirect DR process, when certain initial rotational levels in the molecular ion are coupled to levels in neutral Rydberg states lying below the ion state. Using new procedures for high-resolution electron-ion collision spectroscopy developed here, these resonances in the DR cross section can be measured with high energy sensitivity. This allows a detailed comparison with results of a MQDT calculation in an effort to assign some or all of the resonances to certain intermediate Rydberg levels. (orig.)

  9. Electron collisions and internal excitation in stored molecular ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Buhr, H.

    2006-07-26

    In storage ring experiments the role, which the initial internal excitation of a molecular ion can play in electron collisions, and the effect of these collisions on the internal excitation are investigated. Dissociative recombination (DR) and inelastic and super-elastic collisions are studied in the system of He{sup +}{sub 2}. The DR rate coefficient at low energies depends strongly on the initial vibrational excitation in this system. Therefore changes in the DR rate coefficient are a very sensitive probe for changes in the vibrational excitation in He{sup +}{sub 2}, which is used to investigate the effects of collisions with electrons and residual gas species. The low-energy DR of HD{sup +} is rich with resonances from the indirect DR process, when certain initial rotational levels in the molecular ion are coupled to levels in neutral Rydberg states lying below the ion state. Using new procedures for high-resolution electron-ion collision spectroscopy developed here, these resonances in the DR cross section can be measured with high energy sensitivity. This allows a detailed comparison with results of a MQDT calculation in an effort to assign some or all of the resonances to certain intermediate Rydberg levels. (orig.)

  10. Electronic repository and standardization of processes and electronic documents in transport

    Directory of Open Access Journals (Sweden)

    Tomasz DĘBICKI

    2007-01-01

    Full Text Available The article refers to the idea of the use of electronic repository to store standardised scheme of processes between a Logistics Service Provider and its business partners. Application of repository for automatic or semi-automatic configuration of interoperability in electronic data interchange between information systems of differentcompanies based on transport (road, rail, sea and combined related processes. Standardisation includes processes, scheme of cooperation and related to them, electronic messages.

  11. A method for red blood cell biotinylation in a closed system

    NARCIS (Netherlands)

    de Back, Djuna Z.; Vlaar, Richard; Beuger, Boukje; Daal, Brunette; Lagerberg, Johan; Vlaar, Alexander P. J.; de Korte, Dirk; van Kraaij, Marian; van Bruggen, Robin

    2018-01-01

    Several circumstances require the accurate measurement of red blood cell (RBC) survival and clearance, such as determination of posttransfusion recovery of stored RBCs to investigate the effect of new additive solutions. To this end, biotin as a marker of RBCs to track donor RBCs in the blood of the

  12. Temperature and time stability of whole blood lactate: implications for feasibility of pre-hospital measurement

    Directory of Open Access Journals (Sweden)

    Watkins Timothy R

    2011-05-01

    Full Text Available Abstract Background To determine the time and temperature stability of whole blood lactate using experimental conditions applicable to the out-of-hospital environment. Findings We performed a prospective, clinical laboratory-based study at an academic hospital. Whole blood lactate was obtained by venipuncture from five post-prandial, resting subjects. Blood was stored in lithium heparinized vacutainers in three temperature conditions: 1 room temperature (20°C, 2 wrapped in a portable, instant ice pack (0°C, or 3 wet ice (0°C. Lactate concentrations (mmol/L were measured at 0, 5, 10, 20, and 30 minutes after sampling, and compared using repeated measures analysis of variance. Mean baseline lactate among resting subjects (N = 5 was 1.24 mmol/L (95%CI: 0.49,1.98 mmol/L. After 30 minutes, lactate concentration increased, on average, by 0.08 mmol/L (95%CI: 0.02,0.13 mmol/L, 0.18 mmol/L (95%CI: 0.07,0.28 mmol/L, and 0.36 mmol/L (95%CI: 0.24,0.47 mmol/L when stored in wet ice, ice pack, and room temperature, respectively. The increase in lactate was similar in samples wrapped in portable ice pack or stored in wet ice at all time points (p > 0.05, and met criteria for equivalence at 30 minutes. However, lactate measurements from whole blood stored at room temperature were significantly greater, on average, than wet ice or portable ice pack within five and ten minutes, respectively (p Conclusions Whole blood lactate measurements using samples stored in a portable ice pack are similar to wet ice for up to 30 minutes. These conditions are applicable to the out-of-hospital environment, and should inform future studies of pre-hospital measurement of lactate.

  13. 32 CFR 701.21 - Electronic record.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 5 2010-07-01 2010-07-01 false Electronic record. 701.21 Section 701.21... THE NAVY DOCUMENTS AFFECTING THE PUBLIC FOIA Definitions and Terms § 701.21 Electronic record. Records (including e-mail) which are created, stored, and retrieved by electronic means. ...

  14. Evaluating the use of in-store measures in retail food stores and restaurants in Brazil

    Science.gov (United States)

    Duran, Ana Clara; Lock, Karen; Latorre, Maria do Rosario D O; Jaime, Patricia Constante

    2015-01-01

    ABSTRACT OBJECTIVE To assess inter-rater reliability, test-retest reliability, and construct validity of retail food store, open-air food market, and restaurant observation tools adapted to the Brazilian urban context. METHODS This study is part of a cross-sectional observation survey conducted in 13 districts across the city of Sao Paulo, Brazil in 2010-2011. Food store and restaurant observational tools were developed based on previously available tools, and then tested it. They included measures on the availability, variety, quality, pricing, and promotion of fruits and vegetables and ultra-processed foods. We used Kappa statistics and intra-class correlation coefficients to assess inter-rater and test-retest reliabilities in samples of 142 restaurants, 97 retail food stores (including open-air food markets), and of 62 restaurants and 45 retail food stores (including open-air food markets), respectively. Construct validity as the tool’s abilities to discriminate based on store types and different income contexts were assessed in the entire sample: 305 retail food stores, 8 fruits and vegetable markets, and 472 restaurants. RESULTS Inter-rater and test-retest reliability were generally high, with most Kappa values greater than 0.70 (range 0.49-1.00). Both tools discriminated between store types and neighborhoods with different median income. Fruits and vegetables were more likely to be found in middle to higher-income neighborhoods, while soda, fruit-flavored drink mixes, cookies, and chips were cheaper and more likely to be found in lower-income neighborhoods. CONCLUSIONS The measures were reliable and able to reveal significant differences across store types and different contexts. Although some items may require revision, results suggest that the tools may be used to reliably measure the food stores and restaurant food environment in urban settings of middle-income countries. Such studies can help .inform health promotion interventions and policies in these

  15. Experiential Marketing and Customer Experience - How apparel stores build customer experience and interaction using in-store touchpoints

    OpenAIRE

    Nyberg, Emma; Soini, Mathias

    2017-01-01

    Abstract Purpose:The purpose of this study is to explore in-store touchpoints that help creating a positive customer experience in apparel stores. The aim of this thesis is to provide further insight that may be used for implementation of experiential marketing in stores.   Problem:As e-commerce channels are gaining more customers to the detriment of brick and mortar stores, the authors of this thesis believe it is relevant to study what apparel stores can do to enhance their customer experie...

  16. A Bench Measurement of the Energy Loss of a Stored Beam to a Cavity

    Energy Technology Data Exchange (ETDEWEB)

    Sands, M; Rees, J.; /SLAC

    2016-12-19

    A rather simple electronic bench experiment is proposed for obtaining a measure of the impulse energy loss of a stored particle bunch to an rf cavity or other vacuum-chamber structure--the so-called "cavity radiation". The proposed method is analyzed in some detail.

  17. [Bioactivity of ultraviolet ray-treated titanium surface in nitrogen storing environment].

    Science.gov (United States)

    Wang, Heng; Shang, Ren; Guan, Yun; Wang, Yan; Teng, Wei

    2013-05-01

    To evaluate the adhesion, proliferation and differentiation of osteoblast-like cells on the ultraviolet (UV)-treated titanium in different storing environment, and to find a way to enhance the bioactivity of titanium and to prevent its age-related degradation. Acid-etched titanium disks stored under ambient conditions for 4 weeks and treated with UV light for 48 h.Then disks were divided into three groups and placed in a sealed container for 0 h (no-stored,NO group) , 4 weeks (air-stored, AS group) or in a sealed container filled with nitrogen for 4 weeks (nitrogen-stored,NS group) respectively. A group of UV-untreated titanium served as negative control (NC group).The surface morphology was evaluated using scanning electron microscopy (SEM), and hydrophilicity of disks were measured using contact angle measuring device. Cell counting kit-8 was used to measure the cell adhesion and proliferation. Cell differentiation was evaluated by testing alkaline phosphatase (ALP) activity using ALP reagent kit. There was no difference in surface topography among groups.Contact angels in NS group [(67.70 ± 3.59)°] and NO group [(0.70 ± 0.28)°] were smaller than the others (P 0.05). Osteoblast-like cells had an abundant spread on NS and NO group during 2 h incubation, but did not exactly spread on AS and NC group after incubation for 4 h. No difference were found in ALP among groups. UV treatment can enhance bioactivity of titanium, and nitrogen storage can slow down its biological aging.

  18. Functional Store Image and Corporate Social Responsibility Image: A Congruity Analysis on Store Loyalty

    OpenAIRE

    Jamaliah Mohd. Yusof; Rosidah Musa; Sofiah Abd. Rahman

    2011-01-01

    With previous studies that examined the importance of functional store image and CSR, this study is aimed at examining their effects in the self-congruity model in influencing store loyalty. In particular, this study developed and tested a structural model in the context of retailing industry on the self-congruity theory. Whilst much of the self-congruity studies have incorporated functional store image, there has been lack of studies that examined social responsibility i...

  19. Predicting Commissary Store Success

    Science.gov (United States)

    2014-12-01

    stores or if it is possible to predict that success. Multiple studies of private commercial grocery consumer preferences , habits and demographics have...appropriate number of competitors due to the nature of international cultures and consumer preferences . 2. Missing Data Four of the remaining stores

  20. Signature-based store checking buffer

    Science.gov (United States)

    Sridharan, Vilas; Gurumurthi, Sudhanva

    2015-06-02

    A system and method for optimizing redundant output verification, are provided. A hardware-based store fingerprint buffer receives multiple instances of output from multiple instances of computation. The store fingerprint buffer generates a signature from the content included in the multiple instances of output. When a barrier is reached, the store fingerprint buffer uses the signature to verify the content is error-free.

  1. Corner stores: the perspective of urban youth.

    Science.gov (United States)

    Sherman, Sandra; Grode, Gabrielle; McCoy, Tara; Vander Veur, Stephanie S; Wojtanowski, Alexis; Sandoval, Brianna Almaguer; Foster, Gary D

    2015-02-01

    We examined the perspectives of low-income, urban youth about the corner store experience to inform the development of corner store interventions. Focus groups were conducted to understand youth perceptions regarding their early shopping experiences, the process of store selection, reasons for shopping in a corner store, parental guidance about corner stores, and what their ideal, or "dream corner store" would look like. Thematic analysis was employed to identify themes using ATLAS.ti (version 6.1, 2010, ATLAS.ti GmbH) and Excel (version 2010, Microsoft Corp). Focus groups were conducted in nine kindergarten-through-grade 8 (K-8) public schools in low-income neighborhoods with 40 fourth- to sixth-graders with a mean age of 10.9±0.8 years. Youth report going to corner stores with family members at an early age. By second and third grades, a growing number of youth reported shopping unaccompanied by an older sibling or adult. Youth reported that the products sold in stores were the key reason they choose a specific store. A small number of youth said their parents offered guidance on their corner store purchases. When youth were asked what their dream corner store would look like, they mentioned wanting a combination of healthy and less-healthy foods. These data suggest that, among low-income, urban youth, corner store shopping starts at a very young age and that product, price, and location are key factors that affect corner store selection. The data also suggest that few parents offer guidance about corner store purchases, and youth are receptive to having healthier items in corner stores. Corner store intervention efforts should target young children and their parents/caregivers and aim to increase the availability of affordable, healthier products. Copyright © 2015 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  2. TEMPO DE VIABILIDADE DE AMOSTRAS DE SANGUE VENOSO BOVINO DESTINADAS AO EXAME HEMOGASOMÉTRICO, QUANDO MANTIDAS SOB CONSERVAÇÃO EM ÁGUA GELADA VIABILITY TIME OF BLOOD GAS ANALYSIS IN BOVINE VENOUS BLOOD SAMPLES STORED IN ICE WATER BATH

    Directory of Open Access Journals (Sweden)

    Júlio Augusto Naylor Lisbôa

    2001-04-01

    adequadamente conservadas em banho de água gelada, mantendo, assim, o seu valor diagnóstico.In order to verify the viability of blood gas analysis in bovine venous blood stored on ice water bath, two samples (10ml each were taken from the jugular vein of 14 healthy animals (7 males and 7 females, 1- to 5-year-old, using plastic syringes and attached needles filled with sodium heparin (1,000IU. The blood samples were obtained anaerobically, the air bubbles observed were immediately removed, and the needle was maintened capped with a rubber stopper. Each syringe of the pair was distinctally stored at room temperature (23-30ºC or in ice water bath (0-4ºC during the experimental period. Values of pH, carbon dioxide (PvCO2 and oxigen (PvO2 tensions, bicarbonate (HCO3-, total carbon dioxide (TCO2, base excess (BE, standard bicarbonate (StB, oxigen saturation (SatO2, and oxigen content (O2 were determined soon after sampling and after 1, 2, 3, 4, 5, 6, 8, 10, 12 and 24 hours. According to the type of storage temperature, the results were analysed through repeated measurements ANOVA, considering the contrast between the mean value of each time and the initial one. On the storage at room temperature, the in vitro changes were characterized from continuous decreases in pH, PvO2, BE, StB, SatO2, and O2 values, and gradual increase in PvCO2, starting at 2- or 3-hour after the collection. In the samples stored at 0-4ºC, on the other hand, the changes in pH occurred only at the 4th hour, and the stability of the PvCO2, BE, and StB values were maintened for up to the 6th hour. These results indicated that the diagnostic utility of blood gas analysis is conserved in bovine venous blood samples adequately stored up to 6 hours in ice water bath, at 0-4ºC.

  3. Method and electronic database search engine for exposing the content of an electronic database

    NARCIS (Netherlands)

    Stappers, P.J.

    2000-01-01

    The invention relates to an electronic database search engine comprising an electronic memory device suitable for storing and releasing elements from the database, a display unit, a user interface for selecting and displaying at least one element from the database on the display unit, and control

  4. Beyond Promotion-Based Store Switching : Antecedents and Consequences of Systematic Multiple-Store Shopping

    NARCIS (Netherlands)

    Gijsbrechts, E.; Campo, K.; Nisol, P.

    2005-01-01

    In this paper, we demonstrate that single-purpose multiple store shopping is not only driven by opportunistic, promotion-based motivations, but may also be part of a longer term shopping planning process based on stable store characteristics.Starting from a utility-maximizing shopping behavior

  5. Home blood pressure monitoring, secure electronic messaging and medication intensification for improving hypertension control: a mediation analysis.

    Science.gov (United States)

    Ralston, J D; Cook, A J; Anderson, M L; Catz, S L; Fishman, P A; Carlson, J; Johnson, R; Green, B B

    2014-01-01

    We evaluated the role of home monitoring, communication with pharmacists, medication intensification, medication adherence and lifestyle factors in contributing to the effectiveness of an intervention to improve blood pressure control in patients with uncontrolled essential hypertension. We performed a mediation analysis of a published randomized trial based on the Chronic Care Model delivered over a secure patient website from June 2005 to December 2007. Study arms analyzed included usual care with a home blood pressure monitor and usual care with home blood pressure monitor and web-based pharmacist care. Mediator measures included secure messaging and telephone encounters; home blood pressure monitoring; medications intensification and adherence and lifestyle factors. Overall fidelity to the Chronic Care Model was assessed with the Patient Assessment of Chronic Care (PACIC) instrument. The primary outcome was percent of participants with blood pressure (BP) <140/90 mm Hg. At 12 months follow-up, patients in the web-based pharmacist care group were more likely to have BP <140/90 mm Hg (55%) compared to patients in the group with home blood pressure monitors only (37%) (p = 0.001). Home blood pressure monitoring accounted for 30.3% of the intervention effect, secure electronic messaging accounted for 96%, and medication intensification for 29.3%. Medication adherence and self-report of fruit and vegetable intake and weight change were not different between the two study groups. The PACIC score accounted for 22.0 % of the main intervention effect. The effect of web-based pharmacist care on improved blood pressure control was explained in part through a combination of home blood pressure monitoring, secure messaging, and antihypertensive medication intensification.

  6. Nutrition environments in corner stores in Philadelphia.

    Science.gov (United States)

    Cavanaugh, Erica; Mallya, Giridhar; Brensinger, Colleen; Tierney, Ann; Glanz, Karen

    2013-02-01

    To examine the availability, quality, and price of key types of healthy and less-healthy foods found in corner stores in low-income urban neighborhoods and the associations between store characteristics and store food environments. A sample of 246 corner stores was selected from all corner stores participating in the Philadelphia Healthy Corner Store Initiative (HCSI). The Nutrition Environment Measures Survey for Corner Stores (NEMS-CS) was used to assess the availability, quality, and price of foods and beverages in 11 common categories between February and May, 2011. NEMS-CS measures were completed in 233 stores, 94.7% of the 246 stores approached. The healthier options were significantly less available in all food categories and often more expensive. Baked goods, bread, chips and cereals were sold at nearly all stores, with significantly fewer offering low-fat baked goods (5.7%, pbread (56.2%, pfood environment and dietary choices among low-income urban populations. Availability of certain healthier foods could be improved. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. The Journal of Stored-Products Research: The living history of stored product protection

    Science.gov (United States)

    This year, the Journal of Stored Products Research (JSPR) completes 52 years of history with publications of research papers. With approx. one hundred articles annually, the JSPR is an important scientific forum for stored product researchers throughout the globe. The aims and scope of JSPR are focu...

  8. Information for stores users

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  9. INFORMATION FOR STORES USERS

    CERN Multimedia

    2007-01-01

    From next week, the SFS UNIMARKET (tooling) catalogue will be accessible using the Material Request form on EDH in addition to the CERN Stores catalogue and those of existing suppliers. Users will now be able to place orders from the SFS catalogue using the Material Request form on EDH. Note: The system automatically forwards orders for standard Stores equipment and those for SFS equipment, placed using the same Material Request form, to the CERN Stores and SFS respectively. In both cases, the maximum delivery time will be 48 hours. Requests for equipment will be routed for approval in accordance with standard EDH routing procedures. Logistics Group FI Department

  10. Rethinking the grocery store: inclusive wayfinding system for visually impaired shoppers in grocery stores

    OpenAIRE

    Khattab, Doaa

    2015-01-01

    Many people with disabilities face considerable barriers while shopping in grocery stores.  One such barrier is that they cannot find their way around easily, especially when they visit the grocery store for the first time and have not yet built a cognitive map in their memory. They may also experience delays in finding the right product or waiting for assistance from store employees, thus leading them to rely on family, friends, relatives, or volunteers to help them with their shopping. Prob...

  11. Achieving blood pressure control among renal transplant recipients by integrating electronic health technology and clinical pharmacy services.

    Science.gov (United States)

    Migliozzi, Daniel R; Zullo, Andrew R; Collins, Christine; Elsaid, Khaled A

    2015-11-15

    The implementation and outcomes of a program combining electronic home blood pressure monitoring (HBPM) and pharmacist-provided medication therapy management (MTM) services in a renal transplantation clinic are described. Patients enrolled in the program were provided with a computer-enabled blood pressure monitor. A dedicated renal transplantation pharmacist was integrated into the renal transplantation team under a collaborative care practice agreement. The collaborative care agreement allowed the pharmacist to authorize medication additions, deletions, and dosage changes. Comprehensive disease and blood pressure education was provided by a clinical pharmacist. In the pretransplantation setting, the pharmacist interviewed the renal transplant candidate and documents allergies, verified the patient's medication profile, and identified and assessed barriers to medication adherence. A total of 50 renal transplant recipients with at least one recorded home blood pressure reading and at least one year of follow-up were included in our analysis. A significant reduction in mean systolic and diastolic blood pressure values were observed at 30, 90, 180, and 360 days after enrollment in the program (p services implemented in a renal transplant clinic was associated with sustained improvements in blood pressure control. Incorporation of a pharmacist in the renal transplant clinic resulted in the detection and resolution of medication-related problems. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  12. Breastfeeding FAQs: Safely Storing Breast Milk

    Science.gov (United States)

    ... Search English Español Breastfeeding FAQs: Safely Storing Breast Milk KidsHealth / For Parents / Breastfeeding FAQs: Safely Storing Breast ... may have. How do I store my breast milk? You can freeze and/or refrigerate your pumped ( ...

  13. The management of online resources and long-term saving of electronic documents by transfer into the digital space

    Directory of Open Access Journals (Sweden)

    Marius Daniel MAREŞ

    2011-12-01

    The electronic archive refers to the electronic storage system, along with the totality of electronic-type stored documents, while using as storage support any environment that can support storing and from which an electronic document can be presented.

  14. SURVEY ON THE USE AND THE INTEREST OF INDIVIDUALS IN ONLINE STORES

    Directory of Open Access Journals (Sweden)

    Corina Rusu

    2012-12-01

    Full Text Available In Romania, most products sold in online stores are technology and communication ones. Best sold products through the Internet, globally speaking (games, toys, flowers, watches, tickets, are only 30% of the online products offered in Romania. Culture (books and information only represents 10% of all products, as well as clothing and grooming products. In recent years electronic commerce has had an explosive increase, starting to gain more and more ground on the traditional trade. In what follows, we will analyze the factors that favoured the development of electronic commerce, both in terms of consumers as well as vendors.

  15. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Hamada, Seiki; Takamiya, Makoto; Kuribayashi, Sachio; Naito, Hiroaki

    1994-01-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  16. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Hamada, Seiki [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Takamiya, Makoto [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Kuribayashi, Sachio [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Naito, Hiroaki [Biomedical Research Center, Osaka Univ. School of Medicine, Suita (Japan)

    1994-10-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  17. Understanding Retailers’ Acceptance of Virtual Stores

    Directory of Open Access Journals (Sweden)

    Irene Y.L. Chen

    2010-09-01

    Full Text Available The acceptance of e-commerce among consumers has stimulated the rise of virtual stores. Increasing traditional retailers or people who do not have sufficient capital for maintaining a brick-and-mortar store have considered using virtual stores to reach global market. In the e-commerce literature, there has been rich research evidence concerning consumers’ acceptance of virtual stores. However, rigorous academic research on retailers’ acceptance of virtual stores is relatively scarce today. This study draws upon the theory of planned behavior and information richness theory to propose an integrated theoretical model. A field survey is used to collect data from e-tailers. The data are analyzed to examine the six relationships posited in the research model. Findings of this study provide a further research avenue for e-commerce, and implications for those who are managing or considering using virtual stores.

  18. Consumer behaviour in Apple's App Store

    OpenAIRE

    Ayalew, Romel

    2011-01-01

    Mobile applications stores such as Apple’s App Store and Google’s Android Market revolutionized the distribution of applications for mobile devices. However, with thousands of application submissions, limited testing resources and the lack of an effective filtering mechanism, application stores suffer from information overload and a risk of releasing poor quality applications that could create confusion to consumers and may seriously affect the App store markets. Thus concern has been raised ...

  19. Ethical considerations in umbilical cord blood banking.

    Science.gov (United States)

    Fox, Nathan S; Chervenak, Frank A; McCullough, Laurence B

    2008-01-01

    Pregnant patients have the option at delivery of having their cord blood collected and stored for future use. At many hospitals, they have the option of donating their cord blood to the public banking system for future use by anyone who is an appropriate match (public banking). Patients also have the option of having their cord blood stored for a fee with a commercial/private company for future use within their family (private banking). Currently, private banking is not recommended by major obstetric and pediatric professional organizations. We applied current evidence of the risks and benefits of private and public cord blood banking and accepted ethical principles to answer the following two related questions: 1) Do obstetricians have an ethical obligation to comply with a request for private banking? and 2) Do obstetricians have an ethical obligation to routinely offer private banking to women who do not request it? The only situation where there is a known benefit to private banking is when public banking is not available and the patient currently has an affected family member who may benefit from cord blood therapy. We conclude that when presented with a request for private banking, obstetricians have an ethical obligation to explain the lack of proven benefit of this procedure. If the patient still requests private banking, it would be appropriate to comply, because there is minimal or no risk to the procedure. However, obstetricians are not ethically obligated to offer private banking, even when public banking is not available, except in the limited circumstance when the patient currently has an affected family member who may benefit from cord blood therapy.

  20. Method for extending the useful shelf-life of refrigerated red blood cells by flushing with inert gas

    Science.gov (United States)

    Bitensky, Mark W.; Yoshida, Tatsuro

    1997-01-01

    Method using oxygen removal for extending the useful shelf-life of refrigerated red blood cells. A cost-effective, 4.degree. C. storage procedure that preserves red cell quality and prolongs post-transfusion in vivo survival is described. Preservation of adenosine triphosphate levels and reduction in hemolysis and in membrane vesicle production of red blood cells stored at 4.degree. C. for prolonged periods of time is achieved by removing oxygen therefrom at the time of storage; in particular, by flushing with an inert gas. Adenosine triphosphate levels of the stored red blood cells are boosted in some samples by addition of ammonium phosphate.

  1. Thermal annealing of high dose radiation induced damage at room temperature in alkali halides. Stored energy, thermoluminiscence and colouration

    International Nuclear Information System (INIS)

    Delgado, L.

    1980-01-01

    The possible relation between stored energy, thermoluminiscence and colour centre annealing in gamma and electron irradiated alkali halides is studied. Thermoluminiscence occurs at temperature higher than the temperature at which the main stored energy peak appears. No stored energy release is detected in additively coloured KCl samples. Plastic deformation and doping with Ca and Sr induce a stored energy spectrum different from the spectrum observed in pure and as cleaved samples, but the amount of stored energy does not change for a given irradiation dose. Capacity of alkali halides to sotore energy by irradiation increases as the cation size decreases. It appears that most of the observed release is not related to annealing processes of the radiation induced anion Frenkel pairs. The existence of damage in the cation sublattice with which this energy release might be related is considered. (auth.)

  2. Retail grocery store marketing strategies and obesity: an integrative review.

    Science.gov (United States)

    Glanz, Karen; Bader, Michael D M; Iyer, Shally

    2012-05-01

    In-store food marketing can influence food-purchasing behaviors and warrants increased attention given the dramatic rise in obesity. Descriptive and experimental studies of key marketing components have been conducted by consumer scientists, marketing researchers, and public health experts. This review synthesizes research and publications from industry and academic sources and provides direction for developing and evaluating promising interventions. Literature sources for the review were English-language articles published from 1995 to 2010, identified from multidisciplinary search indexes, backward searches of cited articles, review articles, industry reports, and online sources. Only articles that focused on physical grocery stores and food products were included. Data collection occurred in 2010 and 2011. Articles were classified in the categories of product, price, placement, and promotion and divided into controlled laboratory experiments, observation, and field experiments; 125 primary peer-reviewed articles met the inclusion criteria. Narrative synthesis methods were used. Key findings were synthesized by category of focus and study design. Evidence synthesis was completed in 2011. Findings suggest several strategies for in-store marketing to promote healthful eating by increasing availability, affordability, prominence, and promotion of healthful foods and/or restricting or de-marketing unhealthy foods. Key results of research in controlled laboratory studies should be adapted and tested in real-world in-store settings. Industry methods for assessing consumer behavior, such as electronic sales data and individually linked sales information from loyalty card holders, can help public health researchers increase the scientific rigor of field studies. Copyright © 2012 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  3. In-Store Media and Channel Management

    OpenAIRE

    Anthony Dukes; Yunchuan Liu

    2007-01-01

    In this paper, we study the interesting and complicated effects of retailer in-store media on distribution channel relationships. With the help of advanced technology, retailers can open in-store media in their stores and allow manufacturers to advertise through the instore media. We show that opening in-store media is a strategic decision for a retailer, and a retailer may strategically subsidize manufacturers on their advertising through instore media to better coordinate the channel. Even ...

  4. Iron status in Danish women, 1984-1994: a cohort comparison of changes in iron stores and the prevalence of iron deficiency and iron overload

    DEFF Research Database (Denmark)

    Milman, N.; Byg, K.E.; Ovesen, Lars

    2003-01-01

    Background and objectives: From 1954 to 1986, flour in Denmark was fortified with 30 mg carbonyl iron per kilogram. This mandatory enrichment of cereal products was abolished in 1987. The aim was to evaluate iron status in the Danish female population before and after abolishment of iron...... fortification. Methods: Iron status, serum ferritin and haemoglobin, was assessed in population surveys in 1983-1984 comprising 1221 Caucasian women (1089 non-blood-donors, 130 donors) and in 1993-1994 comprising 1261 women (1155 non-blood-donors, 104 donors) equally distributed in age cohorts of 40, 50, 60......, postmenopausal women had median ferritin of 75 mug/L and in 1994 of 93 mug/L (P iron stores (ferritin iron stores (ferritin less...

  5. Effect of 60Co γ-ray irradiation on cytoskeleton of human peripheral blood monocytes with whole mount cell electron microscopy in vitro

    International Nuclear Information System (INIS)

    Chen Xiaomei; Guo Yuhua; Yin Zhiwei

    1992-01-01

    Whole mount cell electron microscopy was used in combination with selective extraction to prepare cytoskeletal framework. Cytoskeleton prepared by Triton X-100 treatment of human peripheral blood monocytes appeared on electron microscopy as a highly organized and interconnected three-dimensional matrix of different fibrous elements. By three-dimensional visualization of Triton X-100 resistant cytoskeletons it was demonstrated that different doses of 60 Co γ-rays caused distinctive and reproducible alterations of the cytoskeleton of intact human peripheral blood monocytes in vitro. The alterations were similar to those caused by cytochalasin B and by colchicine. From these observations and other workers'studies, it is presumed that 60 Co γ-ray irradiation may inhibit cytoplasmic microtubule and microfilament assembling

  6. Tobacco advertising in retail stores.

    OpenAIRE

    Cummings, K M; Sciandra, R; Lawrence, J

    1991-01-01

    Recent studies have described tobacco advertising in the print media, on billboards, and through sponsorship of cultural and sporting events. However, little attention has been given to another common and unavoidable source of tobacco advertising, that which is encountered in retail stores. In July 1987, we conducted a survey of 61 packaged goods retail stores in Buffalo, NY, to assess the prevalence and type of point-of-sale tobacco advertising. In addition, store owners or managers were sur...

  7. Consumers' quality perception of national branded, national store branded, and imported store branded beef

    DEFF Research Database (Denmark)

    Banovic, Marija; Grunert, Klaus G.; Barreira, Maria Madalena

    2010-01-01

    This study investigated the differences in the consumers' quality perception of national branded, national store branded, and imported store branded beef. Partial Least Squares analysis is used for modelling the quality perception process. Results show that consumers perceived national branded...

  8. The Strategic Management of Store Brand Perceived Quality

    Science.gov (United States)

    Yang, Defeng

    Store brand plays a vital role in the success of retailers. Perceived quality is one of important factors influencing consumers' store brand purchase intention. Store brand perceived quality is lower compared with objective quality or national brand. For this end, the purpose of this article is to examine how to manage store brand perceived quality in strategic level. This article firstly discusses how consumers evaluate product quality, and the theoretical background of the reason that store brand perceived quality is lower from the view of cue related theories. Then, consumers' store brand quality evaluation is explored. Finally, this article presents several strategic tactics to increase store brand perceived quality. These tactics include choosing store's name as store brand name, making large advertising investment, improving store brand product package, and strengthening the relationship with store brand product suppliers.

  9. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W. Sr.

    1992-01-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system use relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, Monte Carlo calculations were performed using the code Electron Gamma Shower (EGS4). Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessel sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was or cross fire between blood vessels was assumed. Results are useful in assessing the doses to blood and blood vessel walls for different nuclear medicine procedures

  10. Electronic Health Object

    Science.gov (United States)

    Almunawar, Mohammad Nabil; Anshari, Muhammad; Younis, Mustafa Z.; Kisa, Adnan

    2015-01-01

    Electronic health records (EHRs) store health-related patient information in an electronic format, improving the quality of health care management and increasing efficiency of health care processes. However, in existing information systems, health-related records are generated, managed, and controlled by health care organizations. Patients are perceived as recipients of care and normally cannot directly interact with the system that stores their health-related records; their participation in enriching this information is not possible. Many businesses now allow customers to participate in generating information for their systems, strengthening customer relationships. This trend is supported by Web 2.0, which enables interactivity through various means, including social networks. Health care systems should be able to take advantage of this development. This article proposes a novel framework in addressing the emerging need for interactivity while preserving and extending existing electronic medical data. The framework has 3 dimensions of patient health record: personal, social, and medical dimensions. The framework is designed to empower patients, changing their roles from static recipient of health care services to dynamic and active partners in health care processes. PMID:26660486

  11. Mechanism of store-operated calcium entry

    Indian Academy of Sciences (India)

    Activation of receptors coupled to the phospholipase C/IP3 signalling pathway results in a rapid release of calcium from its intracellular stores, eventually leading to depletion of these stores. Calcium store depletion triggers an influx of extracellular calcium across the plasma membrane, a mechanism known as the ...

  12. The Heidelberg CSR: Stored Ion Beams in a Cryogenic Environment

    International Nuclear Information System (INIS)

    Wolf, A.; Hahn, R. von; Grieser, M.; Orlov, D. A.; Fadil, H.; Welsch, C. P.; Andrianarijaona, V.; Diehl, A.; Schroeter, C. D.; Crespo Lopez-Urrutia, J. R.; Weber, T.; Mallinger, V.; Schwalm, D.; Ullrich, J.; Rappaport, M.; Urbain, X.; Haberstroh, Ch.; Quack, H.; Zajfman, D.

    2006-01-01

    A cryogenic electrostatic ion storage ring CSR is under development at the Max-Planck Institute for Nuclear Physics in Heidelberg, Germany. Cooling of the ultrahigh vacuum chamber is envisaged to lead to extremely low pressures as demonstrated by cryogenic ion traps. The ring will apply electron cooling with electron beams of a few eV up to 200 eV. Through long storage times of 1000 s as well as through the low wall temperature, internal cooling of infrared-active molecular ions to their rotational ground state will be possible and their collisions with merged collinear beams of electrons and neutral atoms can be detected with high energy resolution. In addition storage of slow highly charged ions is foreseen. Using a fixed in-ring gas target and a reaction microscope, collisions of the stored ions at a speed of the order of the atomic unit can be kinematically reconstructed. The layout and the cryogenic concept are introduced

  13. RETHINKING THE GROCERY STORE: INCLUSIVE WAYFINDING SYSTEM FOR VISUALLY IMPAIRED SHOPPERS IN GROCERY STORES

    Directory of Open Access Journals (Sweden)

    Doaa Khattab

    2015-11-01

    Full Text Available Many people with disabilities face considerable barriers while shopping in grocery stores.  One such barrier is that they cannot find their way around easily, especially when they visit the grocery store for the first time and have not yet built a cognitive map in their memory. They may also experience delays in finding the right product or waiting for assistance from store employees, thus leading them to rely on family, friends, relatives, or volunteers to help them with their shopping. Problems start when these people are not available, in which case the individual is forced to cancel their visit to the grocery store and reschedule the trip. Grocery stores include many different zones and services, the aisles area being one of the main barriers to access for people with different disabilities. This area features many different sections such as canned goods, dry packaged goods, spices, drinks and snacks, baking supplies, baby items, cereals, cleaning products, pet supplies, and health and beauty items. For visually impaired individuals, however, it can be hard to reach these various sections and find the relevant products. The objective of this research is to design an inclusive and innovative wayfinding system in grocery stores for visually impaired shoppers in order to help them find the center zone, orient between different aisles, decide where to go, move easily between different sections, and select products with ease. The research approach will be based on the literature review and the application of the Delphi method.

  14. Heavy metals analysis in blood by the X-ray fluorescence method

    International Nuclear Information System (INIS)

    Perez Novara, Ana Ma.

    1988-05-01

    The analytical procedure for determination of heavy metals in blood is described. Blood was taken from active smelter workers, samples were stored in special flasks at 2 grades C. After freeze drying, dried samples was analyzed using X-ray fluorescence, sources excited: Pu-238 and Cd-109 was used. Br in Pb interferences were corrected. The agreement of the results with values in similar workers is satisfactory Median Pb level was 42.6 micro grams/100 ml (total blood), Cu was less 2.5 micro grams/g (dry blood) and Zn was 11 micro grams/g (dry blood). (author)

  15. THE WHITE BLOOD ANCESTOR?

    OpenAIRE

    M.Arulmani; V.R.Hema Latha

    2014-01-01

    This scientific research article focus that “Red colour blood” of human shall be considered as the 3rd generation Blood and the Human on origin shall be considered having white colour Blood. The white colour blood of human Ancestor shall be considered composed of only ions of Photon, Electron, Proton and free from Hydrogen, Carbon, Nitrogen, Ozone.

  16. Re-thinking the store image study approach

    DEFF Research Database (Denmark)

    Hansen, Kåre

    2001-01-01

    Store image has traditionally been of interest in the Western markets. Studies of store image have also assessed the image of one or a few competing stores. This paper develops an approach to capture store images of an entire retail sector, an issue of importance when enter-ing the new emerging...

  17. Awareness of cord blood banking among pregnant women in semi urban area

    OpenAIRE

    Poomalar G. K.; Jayasree M.

    2016-01-01

    Background: Hematopoietic stem cells (HSCs) are multipotent stem cells, derived from bone marrow, peripheral blood and umbilical cord. These HSC are accepted method of treatment for various disorders. Cord blood can be stored either in private or public bank. Awareness about cord blood banking among semi urban and rural population is less compared to urban population. The aim of our study is to evaluate the awareness of cord blood banking among pregnant women in semi urban area and to evaluat...

  18. Store Image: Scale implementation Part 3

    Directory of Open Access Journals (Sweden)

    Ronel du Preez

    2008-10-01

    Full Text Available This paper is the final in the three-part series regarding store image. The purposes of this article are to (1 implement the developed scale to assess whether it illustrates acceptable psychometric properties of reliability and validity, (2 assess the model fit of the developed scale and (3 formulate recommendations for future research. Results indicated that the Apparel Store Image Scale (ASIS show acceptable reliability and model fit. A refined definition of store image was proposed together with a Final Model of Apparel Store Image. Recommendations for future research are made.

  19. The Key Points of Building an Online Store

    OpenAIRE

    Etuaro, Mari

    2014-01-01

    Online shopping is becoming more popular in Finland and online shopping sales levels have increased. There has been concern that brick and mortar stores are losing their customers to online stores and that Finnish stores are losing their customers to international online stores. One solution to this concern is that Finnish brick and mortar stores also start selling online. But how to build online stores? The aim of this thesis was to study about building an online store based on theory and...

  20. Metal Exposures at three U.S. electronic scrap recycling facilities.

    Science.gov (United States)

    Ceballos, Diana; Beaucham, Catherine; Page, Elena

    2017-06-01

    Many metals found in electronic scrap are known to cause serious health effects, including but not limited to cancer and respiratory, neurologic, renal, and reproductive damage. The National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention performed three health hazard evaluations at electronic scrap recycling facilities in the U.S. to characterize employee exposure to metals and recommend control strategies to reduce these exposures. We performed air, surface, and biological monitoring for metals. We found one overexposure to lead and two overexposures to cadmium. We found metals on non-production surfaces, and the skin and clothing of workers before they left work in all of the facilities. We also found some elevated blood lead levels (above 10 micrograms per deciliter), however no employees at any facility had detectable mercury in their urine or exceeded 34% of the OELs for blood or urine cadmium. This article focuses on sampling results for lead, cadmium, mercury, and indium. We provided recommendations for improving local exhaust ventilation, reducing the recirculation of potentially contaminated air, using respirators until exposures are controlled, and reducing the migration of contaminants from production to non-production areas. We also recommended ways for employees to prevent taking home metal dust by using work uniforms laundered on-site, storing personal and work items in separate lockers, and using washing facilities equipped with lead-removing cleaning products.

  1. Automatic public access to documents and maps stored on and internal secure system.

    Science.gov (United States)

    Trench, James; Carter, Mary

    2013-04-01

    The Geological Survey of Ireland operates a Document Management System for providing documents and maps stored internally in high resolution and in a high level secure environment, to an external service where the documents are automatically presented in a lower resolution to members of the public. Security is devised through roles and Individual Users where role level and folder level can be set. The application is an electronic document/data management (EDM) system which has a Geographical Information System (GIS) component integrated to allow users to query an interactive map of Ireland for data that relates to a particular area of interest. The data stored in the database consists of Bedrock Field Sheets, Bedrock Notebooks, Bedrock Maps, Geophysical Surveys, Geotechnical Maps & Reports, Groundwater, GSI Publications, Marine, Mine Records, Mineral Localities, Open File, Quaternary and Unpublished Reports. The Konfig application Tool is both an internal and public facing application. It acts as a tool for high resolution data entry which are stored in a high resolution vault. The public facing application is a mirror of the internal application and differs only in that the application furnishes high resolution data into low resolution format which is stored in a low resolution vault thus, making the data web friendly to the end user for download.

  2. Recruitment of feces donors among blood donors

    DEFF Research Database (Denmark)

    Dahl Jørgensen, Simon Mark; Erikstrup, Christian; Dinh, Khoa Manh

    2018-01-01

    As the use of fecal microbiota transplantation (FMT) has gained momentum, an increasing need for continuous access to healthy feces donors has developed. Blood donors constitute a healthy subset of the general population and may serve as an appropriate group for recruitment. In this study, we...... investigated the suitability of blood donors as feces donors. In a prospective cohort study, we recruited blood donors onsite at a public Danish blood bank. Following their consent, the blood donors underwent a stepwise screening process: First, blood donors completed an electronic pre-screening questionnaire...... to rule out predisposing risk factors. Second, eligible blood donors had blood and fecal samples examined. Of 155 blood donors asked to participate, 137 (88%) completed the electronic pre-screening questionnaire, 16 declined, and 2 were excluded. Of the 137 donors who completed the questionnaire, 79 (58...

  3. A Comparative Study of the use of Dried Blood on Filter Papers and ...

    African Journals Online (AJOL)

    A study was conducted to compare the suitability of blood collected on filter papers with corresponding fluid serum samples in serodiagnosis of bovine anaplasmosis using DOT-ELISA, RCAT and Western imunobtotting. Serum was obtained from blood collected by jugular venipuncture of288 heads of cattle and stored at ...

  4. Blood cell mRNAs and microRNAs: optimized protocols for extraction and preservation.

    Science.gov (United States)

    Eikmans, Michael; Rekers, Niels V; Anholts, Jacqueline D H; Heidt, Sebastiaan; Claas, Frans H J

    2013-03-14

    Assessing messenger RNA (mRNA) and microRNA levels in peripheral blood cells may complement conventional parameters in clinical practice. Working with small, precious samples requires optimal RNA yields and minimal RNA degradation. Several procedures for RNA extraction and complementary DNA (cDNA) synthesis were compared for their efficiency. The effect on RNA quality of freeze-thawing peripheral blood cells and storage in preserving reagents was investigated. In terms of RNA yield and convenience, quality quantitative polymerase chain reaction signals per nanogram of total RNA and using NucleoSpin and mirVana columns is preferable. The SuperScript III protocol results in the highest cDNA yields. During conventional procedures of storing peripheral blood cells at -180°C and thawing them thereafter, RNA integrity is maintained. TRIzol preserves RNA in cells stored at -20°C. Detection of mRNA levels significantly decreases in degraded RNA samples, whereas microRNA molecules remain relatively stable. When standardized to reference targets, mRNA transcripts and microRNAs can be reliably quantified in moderately degraded (quality index 4-7) and severely degraded (quality index <4) RNA samples, respectively. We describe a strategy for obtaining high-quality and quantity RNA from fresh and stored cells from blood. The results serve as a guideline for sensitive mRNA and microRNA expression assessment in clinical material.

  5. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  6. Dorte Nors "Den store tomat"

    DEFF Research Database (Denmark)

    Michelsen, Jimmi

    2017-01-01

    Tekstgennemgang og undervisningsforløb til Dorte Nors "Den store tomat". Undervisningsforløbet er henvendt til elever i folkeskolens udskoling......Tekstgennemgang og undervisningsforløb til Dorte Nors "Den store tomat". Undervisningsforløbet er henvendt til elever i folkeskolens udskoling...

  7. Prevalence and determinants of declining versus stable hemoglobin levels in whole blood donors

    NARCIS (Netherlands)

    Nasserinejad, Kazem; van Rosmalen, Joost; van den Hurk, Katja; Baart, Mireille; Hoekstra, Trynke; Rizopoulos, Dimitris; Lesaffre, Emmanuel; de Kort, Wim

    2015-01-01

    A too short recovery time after blood donation results in a gradual depletion of iron stores and a subsequent decline in hemoglobin (Hb) levels over time. This decline in Hb levels may depend on individual, unobserved characteristics of the donor. We used a data set of 5388 Dutch blood donors from

  8. Alcoholic fermentation of stored sweet potatoes

    Energy Technology Data Exchange (ETDEWEB)

    Yutaka, Y; One, H

    1958-01-01

    Sweet potatoes were ground and stored in a ground hold. The stored sweet potatoes gave about 90% fermentation efficiency by the koji process. A lower fermentation efficiency by the amylo process was improved by adding 20 to 30 mg/100 ml of organic N. Inorganic N has no effect in improving the fermentation efficiency of the stored sweet potatoes by the amylo process.

  9. Virtual store atmosphere in internet retailing: Measuring virtual retail store layout effects on consumer buying behaviour

    OpenAIRE

    Vrechopoulos, Adam P

    2001-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. The research presented in this dissertation is concerned with the effects of the "virtual store atmosphere" on consumer buying behaviour within the context of Internet retailing. More specifically, the focus of this research is to investigate whether the virtual store layout, as a major virtual store atmosphere determinant, affects consumer buying behaviour during shopping activity w...

  10. Storing Empty Calories and Chronic Disease Risk: Snack-Food Products, Nutritive Content, and Manufacturers in Philadelphia Corner Stores

    OpenAIRE

    Lucan, Sean C.; Karpyn, Allison; Sherman, Sandy

    2010-01-01

    Corner stores are part of the urban food environment that may contribute to obesity and diet-related diseases, particularly for low-income and minority children. The snack foods available in corner stores may be a particularly important aspect of an urban child’s food environment. Unfortunately, there is little data on exactly what snack foods corner stores stock, or where these foods come from. We evaluated snack foods in 17 Philadelphia corner stores, located in three ethnically distinct, l...

  11. Electronic tagging and integrated product intelligence

    Science.gov (United States)

    Swerdlow, Martin; Weeks, Brian

    1996-03-01

    The advent of 'intelligent,' electronic data bearing tags is set to revolutionize the way industrial and retail products are identified and tracked throughout their life cycles. The dominant system for unique identification today is the bar code, which is based on printed symbology and regulated by the International Article Numbering Association. Bar codes provide users with significant operational advantages and generate considerable added value to packaging companies, product manufacturers, distributors and retailers, across supply chains in many different sectors, from retailing, to baggage handling and industrial components, e.g., for vehicles or aircraft. Electronic tags offer the potential to: (1) record and store more complex data about the product or any modifications which occur during its life cycle; (2) access (and up-date) stored data in real time in a way which does not involve contact with the product or article; (3) overcome the limitations imposed by systems which rely on line-of-sight access to stored data. Companies are now beginning to consider how electronic data tags can be used, not only to improve the efficiency of their supply chain processes, but also to revolutionize the way they do business. This paper reviews the applications and business opportunities for electronic tags and outlines CEST's strategy for achieving an 'open' standard which will ensure that tags from different vendors can co-exist on an international basis.

  12. A concept for canceling the leakage field inside the stored beam chamber of a septum magnet

    Science.gov (United States)

    Abliz, M.; Jaski, M.; Xiao, A.; Jain, A.; Wienands, U.; Cease, H.; Borland, M.; Decker, G.; Kerby, J.

    2018-04-01

    The Advanced Photon Source (APS) is planning to upgrade its storage ring from a double-bend achromat to a multi-bend achromat lattice as part of the APS Upgrade Project (APS-U). A swap-out injection scheme is planned for the APS-U in order to keep the beam current constant and to reduce the dynamic aperture requirements. The injection scheme, combined with the constraints in the booster to storage ring transfer region of the APS-U, results in requiring a septum magnet which deflects the injected 6 GeV electron beam by 89 mrad, while not appreciably disturbing the stored beam. The proposed magnet is straight; however, it is rotated in yaw, roll, and pitch from the stored beam chamber to meet the on-axis swap-out injection requirements for the APS-U lattice. The concept utilizes cancellation of the leakage field inside the 8 mm x 6 mm super-ellipsoidal stored beam chamber. As a result, the horizontal deflection angle of the 6 GeV stored beam is reduced to less than 1 μrad with only a 2-mm-thick septum separating the stored beam and the 1.06 T field seen by the injected beam. This design also helps to minimize the integrated skew quadrupole and normal sextupole fields inside the stored beam chamber.

  13. Silent store detection and recording in memory storage

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Pradip; Cher, Chen-Yong; Nair, Ravi

    2017-03-14

    An aspect includes receiving a write request that includes a memory address and write data. Stored data is read from a memory location at the memory address. Based on determining that the memory location was not previously modified, the stored data is compared to the write data. Based on the stored data matching the write data, the write request is completed without writing the write data to the memory and a corresponding silent store bit, in a silent store bitmap is set. Based on the stored data not matching the write data, the write data is written to the memory location, the silent store bit is reset and a corresponding modified bit is set. At least one of an application and an operating system is provided access to the silent store bitmap.

  14. Silent store detection and recording in memory storage

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Pradip; Cher, Chen-Yong; Nair, Ravi

    2017-03-07

    An aspect includes receiving a write request that includes a memory address and write data. Stored data is read from a memory location at the memory address. Based on determining that the memory location was not previously modified, the stored data is compared to the write data. Based on the stored data matching the write data, the write request is completed without writing the write data to the memory and a corresponding silent store bit, in a silent store bitmap is set. Based on the stored data not matching the write data, the write data is written to the memory location, the silent store bit is reset and a corresponding modified bit is set. At least one of an application and an operating system is provided access to the silent store bitmap.

  15. Retail brand architecture and consumer store loyalty

    DEFF Research Database (Denmark)

    Brunsø, Karen; Grunert, Klaus G.

    is to investigate the relationship between consumers perceived retail brand architecture, their store satisfaction and loyalty. Furthermore we use perceived store image as a mediating factor in our framework. In total 772 Danish households participated in a telephone interview and returned questionnaires by mail....... The major contribution of this research is to conceptualise and empirically investigate the role of brand architecture for perceived store image, store satisfaction and loyalty....

  16. Body mass dependence of glycogen stores in the anoxia-tolerant crucian carp ( Carassius carassius L.)

    Science.gov (United States)

    Vornanen, Matti; Asikainen, Juha; Haverinen, Jaakko

    2011-03-01

    Glycogen is a vital energy substrate for anaerobic organisms, and the size of glycogen stores can be a limiting factor for anoxia tolerance of animals. To this end, glycogen stores in 12 different tissues of the crucian carp ( Carassius carassius L.), an anoxia-tolerant fish species, were examined. Glycogen content of different tissues was 2-10 times higher in winter (0.68-18.20% of tissue wet weight) than in summer (0.12-4.23%). In scale, bone and brain glycogen stores were strongly dependent on body mass (range between 0.6 and 785 g), small fish having significantly more glycogen than large fish ( p glycogen reserves, measured as a sum of glycogen from different tissues, varied from 6.1% of the body mass in the 1-g fish to 2.0% in the 800-g fish. Since anaerobic metabolic rate scales down with body size, the whole body glycogen reserves could provide energy for approximately 79 and 88 days of anoxia in small and large fish, respectively. There was, however, a drastic difference in tissue distribution of glycogen between large and small fish: in the small fish, the liver was the major glycogen store (68% of the stores), while in the large fish, the white myotomal muscle was the principal deposit of glycogen (57%). Since muscle glycogen is considered to be unavailable for blood glucose regulation, its usefulness in anoxia tolerance of the large crucian carp might be limited, although not excluded. Therefore, mobilization of muscle glycogen under anoxia needs to be rigorously tested.

  17. The involvement of cation leaks in the storage lesion of red blood cells.

    Directory of Open Access Journals (Sweden)

    Joanna F Flatt

    2014-06-01

    Full Text Available Stored blood components are a critical life-saving tool provided to patients by health services worldwide. Red cells may be stored for up to 42 days, allowing for efficient blood bank inventory management, but with prolonged storage comes an unwanted side-effect known as the ‘storage lesion’, which has been implicated in poorer patient outcomes. This lesion is comprised of a number of processes that are inter-dependent. Metabolic changes include a reduction in glycolysis and ATP production after the first week of storage. This leads to an accumulation of lactate and drop in pH. Longer term damage may be done by the consequent reduction in anti-oxidant enzymes, which contributes to protein and lipid oxidation via reactive oxygen species. The oxidative damage to the cytoskeleton and membrane is involved in increased vesiculation and loss of cation gradients across the membrane. The irreversible damage caused by extensive membrane loss via vesiculation alongside dehydration is likely to result in immediate splenic sequestration of these dense, spherocytic cells. Although often overlooked in the literature, the loss of the cation gradient in stored cells will be considered in more depth in this review as well as the possible effects it may have on other elements of the storage lesion. It has now become clear that blood donors can exhibit quite large variations in the properties of their red cells, including microvesicle production and the rate of cation leak. Further study of stored red blood cells from donors known to have a high or low-rate of cation leak will shed more light on the relationship between cation gradients and the manifestation of the various elements of the storage lesion.

  18. Low stored energy 100 kV regulator for ion sources at LANSCE

    International Nuclear Information System (INIS)

    Jacobson, E.G.; Haffner, R.L.; Ingalls, W.B.; Meyer, B.J.; Stelzer, J.E.

    1998-01-01

    To minimize accelerating column damage caused by uncontrolled energy release during arc-downs, it is desirable to minimize the available stored electrical energy. For the Los Alamos Neutron Science Center (LANSCE) H - ion sources, the stored energy includes, in addition to the charge in the power supply output capacitance, the charge on the electronics racks. They are supported and insulated from ground by PVC pipe and have a capacitance to ground of approximately 900 pf. In 1988 (LANSCE) personnel designed a high-voltage current source using a low-stored-energy power supply and planar triode with the goal of eliminating uncontrolled release of charge stored in the power supply. Construction and testing were performed intermittently as resources permitted until 1993. When work on the Short Pulse Spallation Source (SPSS) started on the LANSCE Ion Source Test Stand (ISTS) it was recognized that a higher current power supply would be needed and work resumed on the regulator circuitry. A 120 kV power supply having low output capacitance, and a planar triode have been used to supply 40 mA, 120 Hz, 12% duty-factor current for the ISTS beam. The triode's cathode current is controlled by circuitry operating both at power-supply voltage level and at ground level via a fiber optic link. Voltage droop is approximately 600 V during the 1 ms beam pulse. The authors present the status of the regulator and its special challenges

  19. Stores, Weight and Inertial System Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides stores weight, center of gravity, and inertia measurements in support of weapon/aircraft compatibility testing. System provides store weight...

  20. Microbiological viability of bovine amniotic membrane stored in glycerin 99% at room temperature for 48 months

    Directory of Open Access Journals (Sweden)

    Kelly Cristine de Sousa Pontes

    Full Text Available ABSTRACT The medium for storing biological tissues is of great importance for their optimal use in surgery. Glycerin has been proven efficient for storing diverse tissues for prolonged time, but the preservation of the bovine amniotic membrane in glycerin 99% at room temperature has never been evaluated to be used safely in surgical procedures. This study evaluated the preservation of 80 bovine amniotic membrane samples stored in glycerin 99% at room temperature. The samples were randomly divided evenly into four groups. Samples were microbiologically tested after 1, 6, 12 and 48 months of storage. The presence of bacteria and fungi in the samples was evaluated by inoculation on blood agar and incubation at 37 ºC for 48 hours and on Sabouraud agar at 25 ºC for 5 to 10 days. No fungal or bacterial growth was detected in any of the samples. It was concluded that glycerin is an efficient medium, regarding microbiology, for preserving pre-prepared bovine amniotic membrane, keeping the tissue free of microorganisms that grow in the media up to 48 months at room temperature.

  1. Insect pests of stored grain products

    International Nuclear Information System (INIS)

    Chuaqui-Offermanns, N.

    1987-01-01

    The presence of insects in stored products is a worldwide recognized problem. In this report chemical and physical methods to control insect infestations in stored products are discussed. Special attention is given to the use of ionizing radiation to control insect pests in stored grains. The radiosensitivity of the most common insect pests at their different developmental stages is presented and discussed. The conclusions of this review are compiled in an executive summary. 62 refs

  2. Electronic Official Personnel Folder System

    Data.gov (United States)

    US Agency for International Development — The eOPF is a digital recreation of paper personnel folder that stores electronic personnel data spanning an individual's Federal career. eOPF allows employees to...

  3. Apple iTunes music store

    OpenAIRE

    Lenzi, R.; Schmucker, M.; Spadoni, F.

    2003-01-01

    This technical report analyses the Apple iTunes Music Store and its success factors. Besides the technical aspects, user and customer aspects as well as content aspects are considered. Furthermore, iTunes Music Store's impact to online music distribution services is analysed and a short outlook to future music online distribution is given.

  4. Cost-effective and rapid blood analysis on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  5. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  6. Automated electronic monitoring of circuit pressures during continuous renal replacement therapy: a technical report.

    Science.gov (United States)

    Zhang, Ling; Baldwin, Ian; Zhu, Guijun; Tanaka, Aiko; Bellomo, Rinaldo

    2015-03-01

    Automated electronic monitoring and analysis of circuit pressures during continuous renal replacement therapy (CRRT) has the potential to predict failure and allow intervention to optimise function. Current CRRT machines can measure and store pressure readings for downloading into databases and for analysis. We developed a procedure to obtain such data at intervals of 1 minute and analyse them using the Prismaflex CRRT machine, and we present an example of such analysis. We obtained data on pressures obtained at intervals of 1 minute in a patient with acute kidney injury and sepsis treated with continuous haemofiltration at 2 L/hour of ultrafiltration and a blood flow of 200 mL/minute. Data analysis identified progressive increases in transmembrane pressure (TMP) and prefilter pressure (PFP) from time 0 until 33 hours or clotting. TMP increased from 104 mmHg to 313 mmHg and PFP increased from from 131 mmHg to 185 mmHg. Effluent pressure showed a progressive increase in the negative pressure applied to achieve ultrafiltration from 0 mmHg to -168 mmHg. The inflection point for such changes was also identified. Blood pathway pressures for access and return remained unchanged throughout. Automated electronic monitoring of circuit pressure during CRRT is possible and provides useful information on the evolution of circuit clotting.

  7. Forhastet regulering af de store

    DEFF Research Database (Denmark)

    Thomsen, Steen

    2013-01-01

    Christiansborg gennemfører sandsynligvis en markant skærpet regulering af de store finansielle virksomheder. Det vil virke kontraktivt og medvirke til erhvervslivets kredittørke.......Christiansborg gennemfører sandsynligvis en markant skærpet regulering af de store finansielle virksomheder. Det vil virke kontraktivt og medvirke til erhvervslivets kredittørke....

  8. Consumers’ preferences regarding department stores

    NARCIS (Netherlands)

    van Laarhoven, W.; Borgers, A.W.J.; van den Berg, P.E.W.

    2017-01-01

    The main reason for this research was the bankruptcy of one the Dutch oldest and largest chain of department stores at the end of 2015. The main goal of this research is to find what, from a consumers’ perspective, a department store should look like. A four storey (1500 m2 each) building was

  9. Baseline extracellular potassium level as an indicator of the rate of increase of the same on further storage in CPDA-1 whole blood units: a potential approach to complement FIFO system for prioritisation of blood bags for release from blood-banks.

    Science.gov (United States)

    Baliarsingh, S; Jaiswal, M

    2014-02-01

    Potassium levels in stored blood bags increases as they age. Hyperkalemia in transfused blood has undesirable cardiac effects. Within a 19-month period, baseline and weekly samples from 15 CPDA-1 whole blood bags were collected till 28 days of storage and analysed for potassium, sodium, uric acid, albumin and whole blood haemoglobin. One unit increase in baseline (0 day) potassium in extracellular fluid of blood units was associated with the following increases in potassium levels on later days of storage: around two unit increase at 1 week (r2 = 0·50, P values. For CPDA-1 blood bags (i) low baseline potassium blood bags might be preferred for transfusion in cases demanding a low potassium load and (ii) coordinating the ‘first-in-first-out’ (FIFO) policy with ‘early release of blood-bags with high initial potassium’ might be helpful in improving the release of suitable blood units from blood-banks.

  10. Reduced ferritin levels in individuals with non-O blood group

    DEFF Research Database (Denmark)

    Rigas, Andreas S; Berkfors, Adam A; Pedersen, Ole B

    2017-01-01

    stores expressed as ferritin levels. STUDY DESIGN AND METHODS: Ferritin levels were measured at least once for 30,595 Danish Blood Donor Study participants. Linear regression analyses were performed with the ABO blood group as explanatory variable and adjusted for age, number of donations 3 years before......BACKGROUND: Genomewide association studies have reported alleles in the ABO locus to be associated with ferritin levels. These studies warrant the investigation of a possible association between the ABO blood group and ferritin levels. We aimed to explore if ABO blood group is associated with iron...... blood group was associated with a ferritin level of less than 15 ng/mL. RESULTS: Non-O blood group donors had lower ferritin levels than blood group O donors, regardless of sex. Accordingly, risk of ferritin level of less than 15 ng/mL was increased for individuals with non-O blood group compared with O...

  11. Length of Storage of Red Blood Cells and Patient Survival After Blood Transfusion

    DEFF Research Database (Denmark)

    Halmin, Märit; Rostgaard, Klaus; Lee, Brian K

    2017-01-01

    received transfusions from 2003 to 2012. Measurements: Patients were followed from first blood transfusion. Relative and absolute risks for death in 30 days or 1 year in relation to length of RBC storage were assessed by using 3 independent analytic approaches. All analyses were conducted by using Cox......Background: Possible negative effects, including increased mortality, among persons who receive stored red blood cells (RBCs) have recently garnered considerable attention. Despite many studies, including 4 randomized trials, no consensus exists. Objective: To study the association between...... the length of RBC storage and mortality in a large population-based cohort of patients who received transfusions, allowing detection of small yet clinically significant effects. Design: Binational cohort study. Setting: All transfusion recipients in Sweden and Denmark. Patients: 854 862 adult patients who...

  12. Virtual blood bank

    Directory of Open Access Journals (Sweden)

    Kit Fai Wong

    2011-01-01

    Full Text Available Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time.

  13. Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin.

    Science.gov (United States)

    Yoo, H M; Pereira, P N R

    2006-01-01

    This study evaluated the effect of blood contamination and decontamination methods on the microtensile bond strength of 1-step self-etching adhesive systems to dentin contaminated after adhesive application and light curing. Three commercially available "all-in-one" adhesives (One Up Bond F, Xeno III and Adper Prompt L-Pop) and 1 resin composite (Clearfil AP-X) were used. Third molars that had been stored in distilled water with 0.5% thymol at 4 degrees C were ground with #600 SiC paper under running water to produce a standardized smear layer. The specimens were randomly divided into groups according to the 3 adhesive systems. The adhesive systems were used under 3 conditions: no contamination, which was the control (C); contamination of the light-cured adhesive surface with blood and reapplication of adhesive (Contamination 1) and contamination of the light-cured adhesive surface with blood, then washing, drying and reapplication of the adhesive (Contamination 2). Following light curing of the adhesive, the resin composite was placed in 3 increments up to a 5-mm-thick layer on the bonded surface. All specimens were stored in distilled water at 37 degrees C for 24 hours. The microtensile bond strength was measured using a universal testing machine (EZ test), and data were analyzed by 1-way ANOVA followed by the Duncan test to make comparisons among the groups (p=0.05). After debonding, 5 specimens were selected from each group and examined in a scanning electron microscope to evaluate the modes of fracture. For all adhesives, contamination groups showed lower bond strength than the control (p0.05). For Xeno III and Adper Prompt L-Pop, contamination group #2 showed the lowest bond strength among the groups (pcontamination group #2 showed higher bond strength than contamination group #1 but showed no statistical significance between them (p>0.05).

  14. Longitudinal Trends in Tobacco Availability, Tobacco Advertising, and Ownership Changes of Food Stores, Albany, New York, 2003-2015.

    Science.gov (United States)

    Hosler, Akiko S; Done, Douglas H; Michaels, Isaac H; Guarasi, Diana C; Kammer, Jamie R

    2016-05-12

    Frequency of visiting convenience and corner grocery stores that sell tobacco is positively associated with the odds of ever smoking and the risk of smoking initiation among youth. We assessed 12-year trends of tobacco availability, tobacco advertising, and ownership changes in various food stores in Albany, New York. Eligible stores were identified by multiple government lists and community canvassing in 2003 (n = 107), 2009 (n = 117), 2012 (n = 135), and 2015 (n = 137). Tobacco availability (all years) and advertising (2009, 2012, and 2015) were directly measured; electronic cigarettes (e-cigarettes) were included in 2015. Percentage of stores selling tobacco peaked at 83.8% in 2009 and declined to 74.5% in 2015 (P for trend = .11). E-cigarettes were sold by 63.7% of tobacco retailers. The largest decline in tobacco availability came from convenience stores that went out of business (n = 11), followed by pharmacies that dropped tobacco sales (n = 4). The gain of tobacco availability mostly came from new convenience stores (n = 24) and new dollar stores (n = 8). Significant declining trends (P advertising in pharmacies and in low (advertising in convenience stores and stores overall. Only one-third of stores that sold tobacco in 2003 continued to sell tobacco with the same owner in 2015. The observed subtle declines in tobacco availability and advertising were explained in part by local tobacco control efforts, the pharmacy industry's self-regulation of tobacco sales, and an increase in the state's tobacco retailer registration fee. Nonetheless, overall tobacco availability remained high (>16 retailers per 10,000 population) in this community. The high store ownership turnover rate suggests that a moratorium of new tobacco retailer registrations would be an integral part of a multi-prong policy strategy to reduce tobacco availability and advertising.

  15. Measurement of insulin-like growth factor-1 and insulin-like growth factor binding protein-3 after delayed separation of whole blood samples

    NARCIS (Netherlands)

    Hartog, Hermien; van der Graaf, Winette T. A.; Wesseling, Jelle; van der Veer, Eveline; Boezen, H. Marike

    Objectives: Epidemiological studies benefit from unbiased blood specimens collected with minimal cost and effort of blood collection and storage. We evaluated the stability of IGF-1 and IGFBP-3 in whole blood samples stored at room temperature to justify delays in blood processing. Design and

  16. Measurement of insulin-like growth factor-1 and insulin-like growth factor binding protein-3 after delayed separation of whole blood samples.

    NARCIS (Netherlands)

    Hartog, H.; Graaf, W.T.A. van der; Wesseling, J.; Veer, E. van der; Boezen, H.M.

    2008-01-01

    OBJECTIVES: Epidemiological studies benefit from unbiased blood specimens collected with minimal cost and effort of blood collection and storage. We evaluated the stability of IGF-1 and IGFBP-3 in whole blood samples stored at room temperature to justify delays in blood processing. DESIGN AND

  17. Senior's lifestyle and their store choice

    Directory of Open Access Journals (Sweden)

    Lesakova Dagmar

    2014-01-01

    Full Text Available To attract and retain customers, an understanding of their motives and reasons for selecting particular food and grocery store is needed. This is of particular importance in the growing segment of seniors. The size of the senior's market demands a better understanding of the older consumer. The aim of our study is to identify psychographic characteristics of the elderly consumer, and to indicate the lifestyle groups and the relationship between these groups and retail store attributes. Differences in the motives for patronizing specific food stores are analyzed for lifestyle groups. We use the lifestyle as a segmentation variable in the diverse population of seniors for the reason, that the lifestyle of the elderly provides more valuable information than chronological age alone. This information can be used by retailers to improve marketing strategies in order to appeal to a target group of senior shoppers. Empirical research is based on a self-administrated questionnaire aimed on the identification of the lifestyle characteristics and retail store attributes of the consumers in 65+ age, used for the choice of food purchasing retail stores. Lifestyles characteristics were measured by the respondents activities, interests and opinions (AIO. The results of the research indicate that there are differences among the lifestyle groups with significant differences in attitudes towards quality of products or internal store environment. Our research demonstrates the value of psychographic information over age alone regarding the patronage factors in store selection. Our study is a part of the research project VEGA 1/0612/12 'Determinants of the size, structure and tendences in the individual consumption of seniors'.

  18. Immersive volume rendering of blood vessels

    Science.gov (United States)

    Long, Gregory; Kim, Han Suk; Marsden, Alison; Bazilevs, Yuri; Schulze, Jürgen P.

    2012-03-01

    In this paper, we present a novel method of visualizing flow in blood vessels. Our approach reads unstructured tetrahedral data, resamples it, and uses slice based 3D texture volume rendering. Due to the sparse structure of blood vessels, we utilize an octree to efficiently store the resampled data by discarding empty regions of the volume. We use animation to convey time series data, wireframe surface to give structure, and utilize the StarCAVE, a 3D virtual reality environment, to add a fully immersive element to the visualization. Our tool has great value in interdisciplinary work, helping scientists collaborate with clinicians, by improving the understanding of blood flow simulations. Full immersion in the flow field allows for a more intuitive understanding of the flow phenomena, and can be a great help to medical experts for treatment planning.

  19. Stored energy in irradiated silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Snead, L.L.; Burchell, T.D. [Oak Ridge National Lab., TN (United States)

    1997-04-01

    This report presents a short review of the phenomenon of Wigner stored energy release from irradiated graphite and discusses it in relation to neutron irradiation of silicon carbide. A single published work in the area of stored energy release in SiC is reviewed and the results are discussed. It appears from this previous work that because the combination of the comparatively high specific heat of SiC and distribution in activation energies for recombining defects, the stored energy release of SiC should only be a problem at temperatures lower than those considered for fusion devices. The conclusion of this preliminary review is that the stored energy release in SiC will not be sufficient to cause catastrophic heating in fusion reactor components, though further study would be desirable.

  20. Experiments with stored relativistic exotic nuclei

    International Nuclear Information System (INIS)

    Klepper, O.; Attallah, F.; Beckert, K.; Bosch, F.; Dolinskiy, A.; Eickhoff, H.; Franczak, B.; Franzke, B.; Geissel, H.; Hausmann, M.; Hellstroem, M.; Herfurth, F.; Kluge, H.-J.; Kozhuharov, C.; Muenzenberg, G.; Nolden, F.; Quint, W.; Tradon, T.; Reich, H.; Scheidenberger, C.; Schlitt, B.; Steck, M.; Suemmerer, K.; Vermeeren, L.; Winkler, M.; Winkler, Th.; Falch, M.; Kerscher, Th.; Loebner, K.E.G.; Fujita, Y.; Novikov, Yu.; Patyk, Z.; Stadlmann, J.; Wollnik, H.

    1999-01-01

    Beams of relativistic exotic nuclei were produced, separated and investigated with the combination of the fragment separator FRS and the storage ring ESR. The following experiments are presented: 1) Direct mass measurements of relativistic nickel and bismuth projectile fragments were performed using Schottky spectrometry. Applying electron cooling, the relative velocity spread of the circulating secondary nuclear beams of low intensity was reduced to below 10 -6 . The achieved mass resolving power of m/Δm = 6.5·10 5 (FWHM) in recent measurements represents an improvement by a factor of two compared to authors' previous experiments. The previously unknown masses of more than 100 proton-rich isotopes have been measured in the range of 54≤Z≤84. The results are compared with mass models and estimated values based on extrapolations of experimental values. 2) Exotic nuclei with half-lives shorter than the time required for electron cooling can be investigated by time-of-flight measurements with the ESR being operated in the isochronous mode. This novel experimental technique has been successfully applied in a first measurement with nickel fragments. A mass resolving power of m/Δm = 1.5·10 5 (FWHM) was achieved in this mode of operation. 3) Nuclear half-lives of stored and cooled bare projectile fragments have been measured to study the influence of the ionic charge state on the beta-decay probability

  1. Cord blood banking and transplantation: advances and controversies.

    Science.gov (United States)

    Yoder, Mervin C

    2014-04-01

    A review of articles published since January 2012 on the topic of cord blood banking and cord blood stem cell transplantation was conducted for this the 25th anniversary year of the first cord blood transplant performed in a human. Cord blood banking is performed throughout the world. Umbilical cord blood (UCB) transplantation is recognized as an acceptable alternative stem cell source for paediatric and adults requiring a haematopoietic transplant, particularly for patients of racial and ethnic minorities. To further advance the use of UCB, methods to enhance UCB stem cell expansion, engraftment and maintenance may be required. Controversy on the most effective and economically sustainable model for banking and storing an optimal UCB product continues to persist. Cord blood banking and transplantation of cord blood stem cells has advanced rapidly over the initial 25 years, as more than 30 ,000 patients have benefited from the therapy. New concepts on the use of methods to expand UCB stem cells for transplantation and use for nonhaematopoietic indications may increase demand for UCB over the next few decades.

  2. Vesicular-arbuscular mycorrhizal populations in stored topsoil

    Energy Technology Data Exchange (ETDEWEB)

    Harris, J.A.; Hunter, D.; Birch, P.; Short, K.C. (North East London Polytechnic, London (UK). Environment and Industry Research Unit, Dept. of Biology and Biochemistry)

    1987-01-01

    Two soil stores of different ages were sampled to investigate their vesicular-arbuscular mycorrhizal (VAM) populations. The soils collected were assessed for pH, moisture content, loss on ignition, spore numbers, number and size of root fragments present and percentage of these roots infected with VAM. A corn-root bioassay was used to determine soil infectivity. Root fragment number, size, % root infection and soil infectivity were negatively correlated with soil depth. VAM spore number was not significantly correlated with depth in either store. It appears that infected root fragments and fresh roots were the source of inoculum although there may have been a contribution from spores in the younger store. The infectivity of the older store soil was less than that of the younger store. 12 refs., 5 tabs.

  3. Significance of myoglobin as an oxygen store and oxygen transporter in the intermittently perfused human heart: a model study.

    Science.gov (United States)

    Endeward, Volker; Gros, Gerolf; Jürgens, Klaus D

    2010-07-01

    The mechanisms by which the left ventricular wall escapes anoxia during the systolic phase of low blood perfusion are investigated, especially the role of myoglobin (Mb), which can (i) store oxygen and (ii) facilitate intracellular oxygen transport. The quantitative role of these two Mb functions is studied in the maximally working human heart. Because discrimination between Mb functions has not been achieved experimentally, we use a Krogh cylinder model here. At a heart rate of 200 beats/min and a 1:1 ratio of diastole/systole, the systole lasts for 150 ms. The basic model assumption is that, with mobile Mb, the oxygen stored in the end-diastolic left ventricle wall exactly meets the demand during the 150 ms of systolic cessation of blood flow. The coronary blood flow necessary to achieve this agrees with literature data. By considering Mb immobile or setting its concentration to zero, respectively, we find that, depending on Mb concentration, Mb-facilitated O(2) transport maintains O(2) supply to the left ventricle wall during 22-34 of the 150 ms, while Mb storage function accounts for a further 12-17 ms. When Mb is completely absent, anoxia begins to develop after 116-99 ms. While Mb plays no significant role during diastole, it supplies O(2) to the left ventricular wall for < or = 50 ms of the 150 ms systole, whereas capillary haemoglobin is responsible for approximately 80 ms. Slight increases in haemoglobin concentration, blood flow, or capillary density can compensate the absence of Mb, a finding which agrees well with the observations using Mb knockout mice.

  4. Fundamental tests of nature with cooled and stored exotic ions

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The presentation will concentrate on recent applications with exciting results of Penning traps in atomic and nuclear physics with cooled and stored exotic ions. These are high-accuracy mass measurements of short-lived radionuclides, g-factor determinations of the bound-electron in highly-charged, hydrogen-like ions and g-factor measurements of the proton and antiproton. The experiments are dedicated, e.g., to astrophysics studies and to tests of fundamental symmetries in the case of mass measurements on radionuclides, and to the determination of fundamental constants and a CPT test in the case of the g-factor measurements.

  5. Stability of creatinine and cystatin C in whole blood

    NARCIS (Netherlands)

    Spithoven, E. M.; Bakker, S. J. L.; Kootstra-Ros, J.E.; de Jong, P. E.; Gansevoort, R. T.

    2013-01-01

    Background: As yet little is known about the effect of delayed separation of whole blood stored at room temperature on the stability of the kidney function markers creatinine and cystatin C. Methods: We used plasma samples of 45 patients with a wide range of creatinine and cystatin C concentration.

  6. Store Separations From a Supersonic Cone

    National Research Council Canada - National Science Library

    Simko, Richard J

    2006-01-01

    ... analyses of supersonic store separations. Also included in this research is a study of supersonic base pressure profiles, near-wake velocity profiles, wind tunnel shock interactions and force/moment studies on a conical store and parent vehicle...

  7. Runaway electrons during tokamak startup

    International Nuclear Information System (INIS)

    Sharma, A.S.; Jayakumar, R.

    1988-01-01

    Runaway electrons significantly affect the plasma and impurity evolution during tokamak startup. During its rise, a runaway pulse stores magnetic flux inductively; this is then released during the decay phase of the runaway pulse. This process affects plasma formation, current initiation and current buildup. Because of their relativistic velocities the runaway electrons have higher ionization and excitation rates than the plasma electrons. This leads to a significant modification of the impurity behaviour and consequently the plasma evolution. (author). 20 refs, 8 figs

  8. Effectiveness of structured teaching programme on knowledge regarding menstrual blood stem cells banking among nursing students

    OpenAIRE

    Neelam Hans; Sandeep Kaur

    2016-01-01

    Background: Menstrual blood banking enables women to store their menstrual blood under required conditions and preserve it for future. Stem cells present in the menstrual blood have the remarkable potential to develop into many different cell types in the body. The objective of the study was to assess the effectiveness of structured teaching programme on knowledge regarding menstrual blood stem cells banking among nursing students studying in selected nursing college of Amritsar, Punjab. M...

  9. Dose rate effect on micronuclei induction in human blood lymphocytes exposed to single pulse and multiple pulses of electrons.

    Science.gov (United States)

    Acharya, Santhosh; Bhat, N N; Joseph, Praveen; Sanjeev, Ganesh; Sreedevi, B; Narayana, Y

    2011-05-01

    The effects of single pulses and multiple pulses of 7 MV electrons on micronuclei (MN) induction in cytokinesis-blocked human peripheral blood lymphocytes (PBLs) were investigated over a wide range of dose rates per pulse (instantaneous dose rate). PBLs were exposed to graded doses of 2, 3, 4, 6, and 8 Gy of single electron pulses of varying pulse widths at different dose rates per pulse, ranging from 1 × 10(6) Gy s(-1) to 3.2 × 10(8) Gy s(-1). Different dose rates per pulse were achieved by changing the dose per electron pulse by adjusting the beam current and pulse width. MN yields per unit absorbed dose after irradiation with single electron pulses were compared with those of multiple pulses of electrons. A significant decrease in the MN yield with increasing dose rates per pulse was observed, when dose was delivered by a single electron pulse. However, no reduction in the MN yield was observed when dose was delivered by multiple pulses of electrons. The decrease in the yield at high dose rates per pulse suggests possible radical recombination, which leads to decreased biological damage. Cellular response to the presence of very large numbers of chromosomal breaks may also alter the damage.

  10. Efficacy of fresh packed red blood transfusion in organophosphate poisoning.

    Science.gov (United States)

    Bao, Hang-Xing; Tong, Pei-Jian; Li, Cai-Xia; Du, Jing; Chen, Bing-Yu; Huang, Zhi-Hui; Wang, Ying

    2017-03-01

    The mortality rate caused by organophosphate (OP) poisoning is still high, even the standard treatment such as atropine and oxime improves a lot. To search for alternative therapies, this study was aimed to investigate the effects of packed red blood cell (RBC) transfusion in acute OP poisoning, and compare the therapeutic effects of RBCs at different storage times.Patients diagnosed with OP poisoning were included in this prospective study. Fresh RBCs (packed RBCs stored less than 10 days) and longer-storage RBCs (stored more than 10 days but less than 35 days) were randomly transfused or not into OP poisoning patients. Cholinesterase (ChE) levels in blood, atropine usage and durations, pralidoxime durations were measured.We found that both fresh and longer-storage RBCs (200-400 mL) significantly increased blood ChE levels 6 hours after transfusion, shortened the duration for ChE recovery and length of hospital stay, and reduced the usage of atropine and pralidoxime. In addition, fresh RBCs demonstrated stronger therapeutic effects than longer-storage RBCs.Packed RBCs might be an alternative approach in patients with OP poisoning, especially during early stages.

  11. [Changes in 2,3-diphosphoglycerate Levels in Blood and Brain Tissue after Craniocerebral Trauma and Cardiac Surgery].

    Science.gov (United States)

    Hausdörfer, J; Heller, W; Junger, H; Oldenkott, P; Stunkat, R

    1976-10-01

    The response of the 2,3-diphosphoglycerate (DPG) levels in the blood and brain tissue to a craniocerebral trauma of varying severity was studied in anaesthetized rats. A trauma producing cerebral contusion was followed within two hours by a highly significant rise in DPG concentration in the blood as compared with the control animals or only mildly traumatized rats. The DPG levels in the brain tissue showed no significant differences. Similar changes in DPG concentration were observed in the blood of patients with craniocerebral injuries. The DPG-mediated increased release of oxygen to the tissues represents a compensatory mechanism and is pathognomic for craniocerebral trauma. Patients undergoing surgery with extracorporeal circulation lack this mechanism for counteracting hypoxaemia; already during thoracotomy the DPG concentration in the blood fell significantly and did not reach its original level until 72 hours after the operation. In stored, ACD stabilized, blood the DPG concentration gradually decreases. Estimations carried out over 28 days showed a continuous statistically significant loss of DPG. After 24 hours the DPG levels in stored blood had already dropped to the lower limits of normal - a fact that has to be taken into account in massive blood transfusions.

  12. effects of catha edulis' leaf extract on blood chemistry and kidney

    African Journals Online (AJOL)

    2014-06-06

    Jun 6, 2014 ... (WHO) has classified khat as a substance of abuse although the .... It was then stored at -20ºC under the ... Blood Samples Collection, and determination of plasma ..... clearance which may be associated with reduced urine.

  13. The School Store...Making It Work. Second Edition. Selling, Buying, Promotion, Operation, Store Security, Management, Accounting.

    Science.gov (United States)

    Michigan State Univ., East Lansing. Michigan Vocational Education Resource Center.

    This handbook is intended as a resource for individuals involved in the development, operation, and expansion of school store laboratories. The first of three sections covers facility/laboratory planning. It includes detailed guidelines for establishing a new school store operation and remodeling or relocating an existing operation. Section II…

  14. Stored energy analysis in the scaled-down test facilities

    International Nuclear Information System (INIS)

    Deng, Chengcheng; Chang, Huajian; Qin, Benke; Wu, Qiao

    2016-01-01

    Highlights: • Three methods are developed to evaluate stored energy in the scaled-down test facilities. • The mechanism behind stored energy distortion in the test facilities is revealed. • The application of stored energy analysis is demonstrated for the ACME facility of China. - Abstract: In the scaled-down test facilities that simulate the accident transient process of the prototype nuclear power plant, the stored energy release in the metal structures has an important influence on the accuracy and effectiveness of the experimental data. Three methods of stored energy analysis are developed, and the mechanism behind stored energy distortion in the test facilities is revealed. Moreover, the application of stored energy analysis is demonstrated for the ACME test facility newly built in China. The results show that the similarity requirements of three methods analyzing the stored energy release decrease gradually. The physical mechanism of stored energy release process can be characterized by the dimensionless numbers including Stanton number, Fourier number and Biot number. Under the premise of satisfying the overall similarity of natural circulation, the stored energy release process in the scale-down test facilities cannot maintain exact similarity. The results of the application of stored energy analysis illustrate that both the transient release process and integral total stored energy of the reactor pressure vessel wall of CAP1400 power plant can be well reproduced in the ACME test facility.

  15. Win-Win Strategies at Discount Stores

    NARCIS (Netherlands)

    B. Deleersnyder (Barbara); M.G. Dekimpe (Marnik); J-B.E.M. Steenkamp (Jan-Benedict); O. Koll (Oliver)

    2005-01-01

    textabstractAn important development that contributes to store brands’ growing success in the grocery market is the increasing number of discount stores that sell predominantly own, private-label, brands. To fight private labels, manufacturers of national brands feel increasingly compelled to

  16. Red blood cells intended for transfusion : quality criteria revisited

    NARCIS (Netherlands)

    Hogman, CF; Meryman, HT

    Great variation exists with respect to viability and function of fresh and stored red blood cells (RBCs) as well as of the contents of RBC hemoglobin (Hb) in individual units. Improved technology is available for the preparation as well as the storage of RBCs. The authors raise the question whether

  17. Quantitative grading of store separation trajectories

    CSIR Research Space (South Africa)

    Jamison, Kevin A

    2017-09-01

    Full Text Available When a new store is integrated with an aircraft, it is necessary to verify that it separates safely for all possible release and emergency jettison scenarios. A large number of store separation analyses are required to comply with this requirement...

  18. The ELSA laser beamline for electron polarization measurements via Compton backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Switka, Michael; Hinterkeuser, Florian; Koop, Rebecca; Hillert, Wolfgang [Electron Stretcher Facility ELSA, Physics Institute of Bonn University (Germany)

    2016-07-01

    The Electron Stretcher Facility ELSA provides a spin polarized electron beam with energies of 0.5 - 3.2 GeV for double polarization hadron physics experiments. As of 2015, the laser beamline of the polarimeter based on Compton backscattering restarted operation. It consists of a cw disk laser with design total beam power of 40 W and features two polarized 515 nm photon beams colliding head-on with the stored electron beam in ELSA. The polarization measurement is based on the vertical profile asymmetry of the back-scattered photons, which is dependent on the polarization degree of the stored electron beam. After recent laser repairs, beamline and detector modifications, the properties of the beamline have been determined and first measurements of the electron polarization degree were conducted. The beamline performance and first measurements are presented.

  19. Longitudinal Trends in Tobacco Availability, Tobacco Advertising, and Ownership Changes of Food Stores, Albany, New York, 2003–2015

    Science.gov (United States)

    Done, Douglas H.; Michaels, Isaac H.; Guarasi, Diana C.; Kammer, Jamie R.

    2016-01-01

    Introduction Frequency of visiting convenience and corner grocery stores that sell tobacco is positively associated with the odds of ever smoking and the risk of smoking initiation among youth. We assessed 12-year trends of tobacco availability, tobacco advertising, and ownership changes in various food stores in Albany, New York. Methods Eligible stores were identified by multiple government lists and community canvassing in 2003 (n = 107), 2009 (n = 117), 2012 (n = 135), and 2015 (n = 137). Tobacco availability (all years) and advertising (2009, 2012, and 2015) were directly measured; electronic cigarettes (e-cigarettes) were included in 2015. Results Percentage of stores selling tobacco peaked at 83.8% in 2009 and declined to 74.5% in 2015 (P for trend = .11). E-cigarettes were sold by 63.7% of tobacco retailers. The largest decline in tobacco availability came from convenience stores that went out of business (n = 11), followed by pharmacies that dropped tobacco sales (n = 4). The gain of tobacco availability mostly came from new convenience stores (n = 24) and new dollar stores (n = 8). Significant declining trends (P advertising in pharmacies and in low (advertising in convenience stores and stores overall. Only one-third of stores that sold tobacco in 2003 continued to sell tobacco with the same owner in 2015. Conclusion The observed subtle declines in tobacco availability and advertising were explained in part by local tobacco control efforts, the pharmacy industry’s self-regulation of tobacco sales, and an increase in the state’s tobacco retailer registration fee. Nonetheless, overall tobacco availability remained high (>16 retailers per 10,000 population) in this community. The high store ownership turnover rate suggests that a moratorium of new tobacco retailer registrations would be an integral part of a multi-prong policy strategy to reduce tobacco availability and advertising. PMID:27172257

  20. Boligmarkedet uden for de store byer

    DEFF Research Database (Denmark)

    Larsen, Jacob Norvig; Andersen, Hans Thor; Haldrup, Karin

    landet som helhed, hvor den østjyske millionby og hovedstaden er migrationens mål. Dermed må der på steder langt fra de store byers infrastruktur og arbejdspladser forventes faldende eller meget begrænset efterspørgsel efter boliger. Det gælder især gamle, dårligt vedligeholdte boliger og boliger med...... og lokalpolitiske planer og indsatser. Tre casestudier belyser, hvordan man i lokalsamfund i tre kommuner uden for de store byer aktivt tager den udfordring op, som følger af en generel strukturændring med øget urbanisering og aldrende befolkning i områderne uden for de store byer. Med blandt andet...... nye samarbejdsformer mellem private, frivillige og kommunale aktører og aktivitets- og beboerhuse som base for foreningsaktivitet er det flere steder lykkedes at tiltrække tilflyttere til samfund langt uden for de store byer....

  1. Pricing of Staple Foods at Supermarkets versus Small Food Stores.

    Science.gov (United States)

    Caspi, Caitlin E; Pelletier, Jennifer E; Harnack, Lisa J; Erickson, Darin J; Lenk, Kathleen; Laska, Melissa N

    2017-08-15

    Prices affect food purchase decisions, particularly in lower-income communities, where access to a range of food retailers (including supermarkets) is limited. The aim of this study was to examine differences in staple food pricing between small urban food stores and the closest supermarkets, as well as whether pricing differentials varied based on proximity between small stores and larger retailers. In 2014, prices were measured for 15 staple foods during store visits in 140 smaller stores (corner stores, gas-marts, dollar stores, and pharmacies) in Minneapolis/St. Paul, MN and their closest supermarket. Mixed models controlling for store type were used to estimate the average price differential between: (a) smaller stores and supermarkets; (b) isolated smaller stores (>1 mile to closest supermarket) and non-isolated smaller stores; and (c) isolated smaller stores inside versus outside USDA-identified food deserts. On average, all items except white bread were 10-54% more expensive in smaller stores than in supermarkets ( p Prices were generally not significantly different in isolated stores compared with non-isolated stores for most items. Among isolated stores, there were no price differences inside versus outside food deserts. We conclude that smaller food stores have higher prices for most staple foods compared to their closest supermarket, regardless of proximity. More research is needed to examine staple food prices in different retail spaces.

  2. nuSTORM - Neutrinos from STORed Muons: Proposal to the Fermilab PAC

    CERN Document Server

    Adey, D.; Ankenbrandt, C.M.; Asfandiyarov, R.; Back, J.J.; Barker, G.; Baussan, E.; Bayes, R.; Bhadra, S.; Blackmore, V.; Blondel, A.; Bogacz, S.A.; Booth, C.; Boyd, S.B.; Bravar, A.; Brice, S.J.; Bross, A.D.; Cadoux, F.; Cease, H.; Cervera, A.; Cobb, J.; Colling, D.; Coloma, P.; Coney, L.; Dobbs, A.; Dobson, J.; Donini, A.; Dornan, P.; Dracos, M.; Dufour, F.; Edgecock, R.; Evans, J.; Geelhoed, M.; George, M.A.; Ghosh, T.; Gomez-Cadenas, J.J.; de Gouvea, A.; Haesler, A.; Hanson, G.; Harrison, P.F.; Hartz, M.; Hernandez, P.; Hernando Morata, J.A.; Hodgson, P.; Huber, P.; Izmaylov, A.; Karadzhov, Y.; Kobilarcik, T.; Kopp, J.; Kormos, L.; Korzenev, A.; Kuno, Y.; Kurup, A.; Kyberd, P.; Lagrange, J.B.; Laing, A.; Liu, A.; Link, J.M.; Long, K.; Mahn, K.; Mariani, C.; Martin, C.; Martin, J.; McCauley, N.; McDonald, K.T.; Mena, O.; Mishra, S.R.; Mokhov, N.; Morfin, J.; Mori, Y.; Murray, W.; Neuffer, D.; Nichol, R.; Noah, E.; Parke, S.; Palmer, M.A.; Pascoli, S.; Pasternak, J.; Popovic, M.; Ratoff, P.; Ravonel, M.; Rayner, M.; Ricciardi, S.; Rogers, C.; Rubinov, P.; Santos, E.; Sato, A.; Sen, T.; Scantamburlo, E.; Sedgbeer, J.K.; Smith, D.R.; Smith, P.J.; Sobczyk, J.T.; Soby, L.; Soler, F.J.P.; Soldner-Rembold, S.; Sorel, M.; Snopok, P.; Stamoulis, P.; Stanco, L.; Striganov, S.; Tanaka, H.A.; Taylor, I.J.; Touramanis, C.; Tunnell, C.D.; Uchida, Y.; Vassilopoulos, N.; Wascko, M.O.; Weber, A.; Wilking, M.J.; Wildner, E.; Winter, W.; Yang, U.K.

    2013-01-01

    The nuSTORM facility has been designed to deliver beams of electron neutrinos and muon neutrinos (and their anti-particles) from the decay of a stored muon beam with a central momentum of 3.8 GeV/c and a momentum acceptance of 10%. The facility is unique in that it will: 1. Allow searches for sterile neutrinos of exquisite sensitivity to be carried out; 2. Serve future long- and short-baseline neutrino-oscillation programs by providing definitive measurements of electron neutrino and muon neutrino scattering cross sections off nuclei with percent-level precision; and 3. Constitutes the crucial first step in the development of muon accelerators as a powerful new technique for particle physics. The document describes the facility in detail and demonstrates its physics capabilities. This document was submitted to the Fermilab Physics Advisory Committee in consideration for Stage I approval.

  3. Information from the central stores

    CERN Multimedia

    GS Department

    2010-01-01

    All items sold in the CERN shop (Bldg. 33) are now available in the central stores (Bldg. 73) and can be purchased on-line via EDH “Material Request” or at the “Emergency Desk” of the stores on the ground floor of Bldg. 73. These items are visible in the CERN catalogue under the “SCEM” codes beginning with 92. Department of General Infrastructure Services (GS) GS-SEM Group

  4. Compliance to two city convenience store ordinance requirements

    Science.gov (United States)

    Menéndez, Cammie K Chaumont; Amandus, Harlan E; Wu, Nan; Hendricks, Scott A

    2015-01-01

    Background Robbery-related homicides and assaults are the leading cause of death in retail businesses. Robbery reduction approaches focus on compliance to Crime Prevention Through Environmental Design (CPTED) guidelines. Purpose We evaluated the level of compliance to CPTED guidelines specified by convenience store safety ordinances effective in 2010 in Dallas and Houston, Texas, USA. Methods Convenience stores were defined as businesses less than 10 000 square feet that sell grocery items. Store managers were interviewed for store ordinance requirements from August to November 2011, in a random sample of 594 (289 in Dallas, 305 in Houston) convenience stores that were open before and after the effective dates of their city’s ordinance. Data were collected in 2011 and analysed in 2012–2014. Results Overall, 9% of stores were in full compliance, although 79% reported being registered with the police departments as compliant. Compliance was consistently significantly higher in Dallas than in Houston for many requirements and by store type. Compliance was lower among single owner-operator stores compared with corporate/franchise stores. Compliance to individual requirements was lowest for signage and visibility. Conclusions Full compliance to the required safety measures is consistent with industry ‘best practices’ and evidence-based workplace violence prevention research findings. In Houston and Dallas compliance was higher for some CPTED requirements but not the less costly approaches that are also the more straightforward to adopt. PMID:26337569

  5. The Antecedents of Store Image and Customer Satisfaction

    Directory of Open Access Journals (Sweden)

    Banu Kulter Demirgunes

    2016-01-01

    Full Text Available Definition of store image is argued to be useful if it predicts phenomena such as satisfaction, loyalty, customer retention and other attitudinal and behavioral outcomes. Previous researches show that customers are affected by the store attributes and consider them to assess perceived benefits and attitudes. One of the biggest challenges for companies is to build a positive image. Knowing the alternatives which could be used to form a positive image is an important issue. A positive image which is created in the customer’s mind about store is seen to have a strong and positive influence on satisfaction. A satisfied customer is likely to be loyal to the store. Therefore, image and customer satisfaction gain importance in the stores which aim to survive. This study focuses on store image, customer satisfaction and the relationship between them. The study primarily explains these two concepts, and then provides a literature review on the researches related with them. The study presents researches in which store image and customer satisfaction are separately discussed, thus it also shows other variables which can be influential on these concepts. Implications for both store image theory and practices are discussed. The literature review reveals that store image plays an important role in customer satisfaction.  Since most of the studies in literature are based on retail industry, in this study ‘store’ concept mostly refers to ‘retail store’.

  6. Individual and Store Characteristics Associated with Brand Choices in Select Food Category Redemptions among WIC Participants in Virginia

    Directory of Open Access Journals (Sweden)

    Qi Zhang

    2017-03-01

    Full Text Available The Special Supplemental Nutrition Program for Women, Infants, and Children (WIC often allows participants to redeem food benefits for various brands at different costs. To aid the program’s food cost containment efforts, it is important to understand the individual and store characteristics associated with brand choices. This study used the WIC Electronic Benefit Transfer (EBT data for 239,062 Virginia WIC participants’ brand choices in infant fruits and vegetables (F&Vs and whole grain bread in May 2014–February 2015, one of the first such data sets available in the U.S. for research purposes. Mixed effects logistic regression models were used to analyze the choice of higher-priced brands over lower-priced brands. Minority participants were significantly more likely to redeem higher-priced brands of infant F&Vs, but more likely to choose lower-priced brands of bread. Participants shopping in urban stores or midsized stores (with 5–9 registers were less likely to choose higher-priced brands compared to rural stores or large stores (with 9+ registers. Race/ethnicity and store characteristics may be significant factors in participants’ brand choices. The results can help develop interventions that encourage targeted participants to redeem lower-priced but equivalently healthy brands. This may not only help contain WIC program costs, but help participants manage their own non-WIC food expenses as well.

  7. Individual and Store Characteristics Associated with Brand Choices in Select Food Category Redemptions among WIC Participants in Virginia

    Science.gov (United States)

    Zhang, Qi; Tang, Chuanyi; McLaughlin, Patrick W.; Diggs, Leigh

    2017-01-01

    The Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) often allows participants to redeem food benefits for various brands at different costs. To aid the program’s food cost containment efforts, it is important to understand the individual and store characteristics associated with brand choices. This study used the WIC Electronic Benefit Transfer (EBT) data for 239,062 Virginia WIC participants’ brand choices in infant fruits and vegetables (F&Vs) and whole grain bread in May 2014–February 2015, one of the first such data sets available in the U.S. for research purposes. Mixed effects logistic regression models were used to analyze the choice of higher-priced brands over lower-priced brands. Minority participants were significantly more likely to redeem higher-priced brands of infant F&Vs, but more likely to choose lower-priced brands of bread. Participants shopping in urban stores or midsized stores (with 5–9 registers) were less likely to choose higher-priced brands compared to rural stores or large stores (with 9+ registers). Race/ethnicity and store characteristics may be significant factors in participants’ brand choices. The results can help develop interventions that encourage targeted participants to redeem lower-priced but equivalently healthy brands. This may not only help contain WIC program costs, but help participants manage their own non-WIC food expenses as well. PMID:28362350

  8. Individual and Store Characteristics Associated with Brand Choices in Select Food Category Redemptions among WIC Participants in Virginia.

    Science.gov (United States)

    Zhang, Qi; Tang, Chuanyi; McLaughlin, Patrick W; Diggs, Leigh

    2017-03-31

    The Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) often allows participants to redeem food benefits for various brands at different costs. To aid the program's food cost containment efforts, it is important to understand the individual and store characteristics associated with brand choices. This study used the WIC Electronic Benefit Transfer (EBT) data for 239,062 Virginia WIC participants' brand choices in infant fruits and vegetables (F&Vs) and whole grain bread in May 2014-February 2015, one of the first such data sets available in the U.S. for research purposes. Mixed effects logistic regression models were used to analyze the choice of higher-priced brands over lower-priced brands. Minority participants were significantly more likely to redeem higher-priced brands of infant F&Vs, but more likely to choose lower-priced brands of bread. Participants shopping in urban stores or midsized stores (with 5-9 registers) were less likely to choose higher-priced brands compared to rural stores or large stores (with 9+ registers). Race/ethnicity and store characteristics may be significant factors in participants' brand choices. The results can help develop interventions that encourage targeted participants to redeem lower-priced but equivalently healthy brands. This may not only help contain WIC program costs, but help participants manage their own non-WIC food expenses as well.

  9. Distributed energy store railguns experiment and analysis

    International Nuclear Information System (INIS)

    Holland, L.D.

    1984-01-01

    Electromagnetic acceleration of projectiles holds the potential for achieving higher velocities than yet achieved by any other means. A railgun is the simplest form of electromagnetic macroparticle accelerator and can generate the highest sustained accelerating force. The practical length of conventional railguns is limited by the impedance of the rails because current must be carried along the entire length of the rails. A railgun and power supply system called the distributed energy store railgun was proposed as a solution to this limitation. The distributed energy store railgun used multiple current sources connected to the rails of a railgun at points distributed along the bore. These current sources (energy stores) are turned on in sequence as the projectile moves down the bore so that current is fed to the railgun from behind the armature. In this system the length of the rails that carry the full armature current is less than the total length of the railgun. If a sufficient number of energy stores is used, this removes the limitation on the length of a railgun. An additional feature of distributed energy store type railguns is that they can be designed to maintain a constant pressure on the projectile being accelerated. A distributed energy store railgun was constructed and successfully operated. In addition to this first demonstration of the distributed energy store railgun principle, a theoretical model of the system was also constructed

  10. EAST: Developing an Electronic Assessment and Storage Tool.

    Science.gov (United States)

    Edwards, Katherine I.; Fernandez, Eugenia; Milionis, Tracey M.; Williamson, David M.

    2002-01-01

    Describes the purpose, development, analysis, prototyping, and features of the Electronic Assessment and Storage Tool (EAST). The Web-based system aids curriculum assessment at Purdue School of Engineering and Technology at Indiana University Purdue University Indianapolis through the ability to easily store artifacts in electronic form, support…

  11. 76 FR 19741 - Exemption for Retail Store Operations

    Science.gov (United States)

    2011-04-08

    ... the types of operations traditionally and usually conducted at retail stores and restaurants when those operations are conducted at any retail store or restaurant or similar retail-type establishment... Retail Store Operations AGENCY: Food Safety and Inspection Service, USDA. [[Page 19742

  12. Mechanical and electrical properties of red blood cells using optical tweezers

    International Nuclear Information System (INIS)

    Fontes, A; Castro, M L Barjas; Brandão, M M; Fernandes, H P; Huruta, R R; Costa, F F; Saad, S T O; Thomaz, A A; Pozzo, L Y; Barbosa, L C; Cesar, C L

    2011-01-01

    Optical tweezers are a very sensitive tool, based on photon momentum transfer, for individual, cell by cell, manipulation and measurements, which can be applied to obtain important properties of erythrocytes for clinical and research purposes. Mechanical and electrical properties of erythrocytes are critical parameters for stored cells in transfusion centers, immunohematological tests performed in transfusional routines and in blood diseases. In this work, we showed methods, based on optical tweezers, to study red blood cells and applied them to measure apparent overall elasticity, apparent membrane viscosity, zeta potential, thickness of the double layer of electrical charges and adhesion in red blood cells

  13. Nudging consumer behaviour in retail stores

    DEFF Research Database (Denmark)

    Adam, Abdulfatah

    2016-01-01

    -effectiveness of alternative interventions in retail store settings. In cooperation with a supermarket chain in Denmark, we manipulated food locations inside the store so that relatively low energy dense products were placed favorable shelf locations. The underlying theory for the experiment was the behavioral approach (so...

  14. The functions of store-operated calcium channels.

    Science.gov (United States)

    Putney, James W; Steinckwich-Besançon, Natacha; Numaga-Tomita, Takuro; Davis, Felicity M; Desai, Pooja N; D'Agostin, Diane M; Wu, Shilan; Bird, Gary S

    2017-06-01

    Store-operated calcium channels provide calcium signals to the cytoplasm of a wide variety of cell types. The basic components of this signaling mechanism include a mechanism for discharging Ca 2+ stores (commonly but not exclusively phospholipase C and inositol 1,4,5-trisphosphate), a sensor in the endoplasmic reticulum that also serves as an activator of the plasma membrane channel (STIM1 and STIM2), and the store-operated channel (Orai1, 2 or 3). The advent of mice genetically altered to reduce store-operated calcium entry globally or in specific cell types has provided important tools to understand the functions of these widely encountered channels in specific and clinically important physiological systems. This review briefly discusses the history and cellular properties of store-operated calcium channels, and summarizes selected studies of their physiological functions in specific physiological or pathological contexts. This article is part of a Special Issue entitled: ECS Meeting edited by Claus Heizmann, Joachim Krebs and Jacques Haiech. Published by Elsevier B.V.

  15. Observation of Electron Cloud Instabilities and Emittance Dilution at the Cornell Electron-Positron Storage Ring Test Accelerator

    International Nuclear Information System (INIS)

    Holtzapple, R.L.; Campbell, R.C.; McArdle, K.E.; Miller, M.I.; Totten, M.M.; Tucker, S.L.; Billing, M.G.; Dugan, G.F.; Ramirez, G.A.; Sonnad, K.G.; Williams, H.A.; Flanagan, J.; Palmer, M.A.

    2016-01-01

    Electron cloud related emittance dilution and instabilities of bunch trains limit the performance of high intensity circular colliders. One of the key goals of the Cornell electron-positron storage ring Test Accelerator (CesrTA) research program is to improve our understanding of how the electron cloud alters the dynamics of bunches within the train. Single bunch beam diagnotics have been developed to measure the beam spectra, vertical beam size, two important dynamical effects of beams interacting with the electron cloud, for bunch trains on a turn-by-turn basis. Experiments have been performed at CesrTA to probe the interaction of the electron cloud with stored positron bunch trains. The purpose of these experiments was to characterize the dependence of beam-electron cloud interactions on the machine parameters such as bunch spacing, vertical chromaticity, and bunch current. The beam dynamics of the stored beam, in the presence of the electron cloud, was quantified using: 1) a gated beam position monitor (BPM) and spectrum analyzer to measure the bunch-by-bunch frequency spectrum of the bunch trains; 2) an x-ray beam size monitor to record the bunch-by-bunch, turn-by-turn vertical size of each bunch within the trains. In this paper we report on the observations from these experiments and analyze the effects of the electron cloud on the stability of bunches in a train under many different operational conditions

  16. Propagating separable equalities in an MDD store

    DEFF Research Database (Denmark)

    Hadzic, Tarik; Hooker, John N.; Tiedemann, Peter

    2008-01-01

    We present a propagator that achieves MDD consistency for a separable equality over an MDD (multivalued decision diagram) store in pseudo-polynomial time. We integrate the propagator into a constraint solver based on an MDD store introduced in [1]. Our experiments show that the new propagator pro...... provides substantial computational advantage over propagation of two inequality constraints, and that the advantage increases when the maximum width of the MDD store increases....

  17. 75 FR 66110 - Guidelines for Use of Stored Specimens and Access to Ancillary Data and Proposed Cost Schedule...

    Science.gov (United States)

    2010-10-27

    ..., obstetric, pediatric, infant neurological, and child psychological information. Electronic data files, forms... that the project is intended to fill. State concisely the importance of the research in terms of the... be reported immediately to a participant is not appropriate for testing on the stored samples. (5...

  18. Insect pest management in stored grain

    Science.gov (United States)

    Stored grain is vulnerable to attach by a variety of insect pests, that can generally be classified as external or internal feeders. Infestations primarily occur after grain is stored, though there is some evidence that infestations can occur in the field right before harvest. There are a variety of...

  19. Compliance to two city convenience store ordinance requirements.

    Science.gov (United States)

    Chaumont Menéndez, Cammie K; Amandus, Harlan E; Wu, Nan; Hendricks, Scott A

    2016-04-01

    Robbery-related homicides and assaults are the leading cause of death in retail businesses. Robbery reduction approaches focus on compliance to Crime Prevention Through Environmental Design (CPTED) guidelines. We evaluated the level of compliance to CPTED guidelines specified by convenience store safety ordinances effective in 2010 in Dallas and Houston, Texas, USA. Convenience stores were defined as businesses less than 10 000 square feet that sell grocery items. Store managers were interviewed for store ordinance requirements from August to November 2011, in a random sample of 594 (289 in Dallas, 305 in Houston) convenience stores that were open before and after the effective dates of their city's ordinance. Data were collected in 2011 and analysed in 2012-2014. Overall, 9% of stores were in full compliance, although 79% reported being registered with the police departments as compliant. Compliance was consistently significantly higher in Dallas than in Houston for many requirements and by store type. Compliance was lower among single owner-operator stores compared with corporate/franchise stores. Compliance to individual requirements was lowest for signage and visibility. Full compliance to the required safety measures is consistent with industry 'best practices' and evidence-based workplace violence prevention research findings. In Houston and Dallas compliance was higher for some CPTED requirements but not the less costly approaches that are also the more straightforward to adopt. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Attenuation of Red Blood Cell Storage Lesions with Vitamin C

    Directory of Open Access Journals (Sweden)

    Kimberly Sanford

    2017-07-01

    Full Text Available Stored red blood cells (RBCs undergo oxidative stress that induces deleterious metabolic, structural, biochemical, and molecular changes collectively referred to as “storage lesions”. We hypothesized that vitamin C (VitC, reduced or oxidized would reduce red cell storage lesions, thus prolonging their storage duration. Whole-blood-derived, leuko-reduced, SAGM (saline-adenine-glucose-mannitol-preserved RBC concentrates were equally divided into four pediatric storage bags and the following additions made: (1 saline (saline; (2 0.3 mmol/L reduced VitC (Lo VitC; (3 3 mmol/L reduced VitC (Hi VitC; or (4 0.3 mmol/L oxidized VitC (dehydroascorbic acid, DHA as final concentrations. Biochemical and rheological parameters were serially assessed at baseline (prior to supplementation and Days 7, 21, 42, and 56 for RBC VitC concentration, pH, osmotic fragility by mechanical fragility index, and percent hemolysis, LDH release, glutathione depletion, RBC membrane integrity by scanning electron microscopy, and Western blot for β-spectrin. VitC exposure (reduced and oxidized significantly increased RBC antioxidant status with varying dynamics and produced trends in reduction in osmotic fragility and increases in membrane integrity. Conclusion: VitC partially protects RBC from oxidative changes during storage. Combining VitC with other antioxidants has the potential to improve long-term storage of RBC.

  1. Iron deficiency in blood donors

    Directory of Open Access Journals (Sweden)

    Rodolfo Delfini Cançado

    Full Text Available CONTEXT: Blood donation results in a substantial loss of iron (200 to 250 mg at each bleeding procedure (425 to 475 ml and subsequent mobilization of iron from body stores. Recent reports have shown that body iron reserves generally are small and iron depletion is more frequent in blood donors than in non-donors. OBJECTIVE: The aim of this study was to evaluate the frequency of iron deficiency in blood donors and to establish the frequency of iron deficiency in blood donors according to sex, whether they were first-time or multi-time donors, and the frequency of donations per year. DESIGN: From September 20 to October 5, 1999, three hundred blood donors from Santa Casa Hemocenter of São Paulo were studied. DIAGNOSTIC TESTS: Using a combination of biochemical measurements of iron status: serum iron, total iron-binding capacity, transferrin saturation index, serum ferritin and the erythrocyte indices. RESULTS: The frequency of iron deficiency in blood donors was 11.0%, of whom 5.5% (13/237 were male and 31.7% (20/63 female donors. The frequency of iron deficiency was higher in multi-time blood donors than in first-time blood donors, for male blood donors (7.6% versus 0.0%, P < 0.05 and female ones (41.5% versus 18.5%, P < 0.05. The frequency of iron deficiency found was higher among the male blood donors with three or more donations per year (P < 0.05 and among the female blood donors with two or more donations per year (P < 0.05. CONCLUSIONS: We conclude that blood donation is a very important factor for iron deficiency in blood donors, particularly in multi-time donors and especially in female donors. The high frequency of blood donors with iron deficiency found in this study suggests a need for a more accurate laboratory trial, as hemoglobin or hematocrit measurement alone is not sufficient for detecting and excluding blood donors with iron deficiency without anemia.

  2. Information for Stores users

    CERN Multimedia

    FI Department

    2008-01-01

    The DISTRELEC catalogue (IT) is now available in EDH in addition to the CERN Stores catalogue and the catalogues of existing suppliers. Using an EDH materials request form, users can now order DISTRELEC equipment from amongst the following product groups: peripherals, multimedia, PC components, data media, communication and data cables and adapters. Non-authorised materials will be clearly indicated. As a reminder, the system automatically manages the distribution of standard Stores equipment and punch out equipment ordered on the same request form. In both cases, delivery will take a maximum of 48 hours. The approval of the EDH document will follow the usual EDH routing procedures. Logistics Group FI Department

  3. Characterization of bacteriophages infecting clinical isolates of Pseudomonas aeruginosa stored in a culture collection

    Directory of Open Access Journals (Sweden)

    C.C.S. Zanetti

    2013-08-01

    Full Text Available Some clinical isolates of Pseudomonas aeruginosa stored in our culture collection did not grow or grew poorly and showed lysis on the culture plates when removed from the collection and inoculated on MacConkey agar. One hypothesis was that bacteriophages had infected and killed those clinical isolates. To check the best storage conditions to maintain viable P. aeruginosa for a longer time, clinical isolates were stored at various temperatures and were grown monthly. We investigated the presence of phage in 10 clinical isolates of P. aeruginosa stored in our culture collection. Four strains of P. aeruginosa were infected by phages that were characterized by electron microscopy and isolated to assess their ability to infect. The best condition to maintain the viability of the strains during storage was in water at room temperature. Three Siphoviridae and two Myoviridae phages were visualized and characterized by morphology. We confirmed the presence of bacteriophages infecting clinical isolates, and their ability to infect and lyse alternative hosts. Strain PAO1, however, did not show lysis to any phage. Mucoid and multidrug resistant strains of P. aeruginosa showed lysis to 50% of the phages tested.

  4. Stored energy analysis in scale-down test facility

    International Nuclear Information System (INIS)

    Deng Chengcheng; Qin Benke; Fang Fangfang; Chang Huajian; Ye Zishen

    2013-01-01

    In the integral test facilities that simulate the accident transient process of the prototype nuclear power plant, the stored energy in the metal components has a direct influence on the simulation range and the test results of the facilities. Based on the heat transfer theory, three methods analyzing the stored energy were developed, and a thorough study on the stored energy problem in the scale-down test facilities was further carried out. The lumped parameter method and power integration method were applied to analyze the transient process of energy releasing and to evaluate the average total energy stored in the reactor pressure vessel of the ACME (advanced core-cooling mechanism experiment) facility, which is now being built in China. The results show that the similarity requirements for such three methods to analyze the stored energy in the test facilities are reduced gradually. Under the condition of satisfying the integral similarity of natural circulation, the stored energy releasing process in the scale-down test facilities can't maintain exact similarity. The stored energy in the reactor pressure vessel wall of ACME, which is released quickly during the early stage of rapid depressurization of system, will not make a major impact on the long-term behavior of system. And the scaling distortion of integral average total energy of the stored heat is acceptable. (authors)

  5. EFFECTS OF STORAGE, RNA EXTRACTION, GENECHIP TYPE, AND DONOR SEX ON GENE EXPRESSION PROFILING OF HUMAN WHOLE BLOOD

    Science.gov (United States)

    Background: Gene expression profiling of whole blood may be useful for monitoring toxicological exposure and for diagnosis and monitoring of various diseases. Several methods are available that can be used to transport, store, and extract RNA from whole blood, but it is not clear...

  6. Perturbed Motion of Airplane and Safe Store Separation

    OpenAIRE

    S. C. Raisinghani; S. Rao

    1983-01-01

    A method is presented to predict the perturbed motion of an airplane following stores jettisoning. The mass, moment of inertia, forces, and moments acting on the airplane are suitable split into contributions from the stores and the rest of the airplane parts. The seperation of stores is assumed to result in a step change of mass, moment of intertai, forces, and moments contributed by stores. The resulting set of perturbed state equations of motion are solved for two illustrative airplane str...

  7. Ultrastructure of Pericystic or Intracystic Blood Vessels in Epidermoid Cysts-A Transmission Electron Microscopy Study: Laboratory Investigation.

    Science.gov (United States)

    Ren, Xiao-Hui; Ma, Jun; Zeng, Chun; Sun, Yi-Lin; Lin, Song

    2017-07-01

    Recently, we reported a tendency toward spontaneous hemorrhage in both the preoperative and postoperative periods in patients with intracranial epidermoid cyst (EC). According to our experience, this tendency for spontaneous hemorrhage was partly caused by the pathologic blood vessels adjacent to the EC. This study was designed to testify this hypothesis. Twenty-three removable pericystic or intracystic blood vessels from 17 patients with EC were collected during surgery and were then examined by transmission electron microscopy. The microvascular structure in gliomas was chosen as the control. Under electron microscopy, variant pathologic changes of vessels were found in all patients with EC. In the tunicae intima, we found vacuolization, apoptosis, necrosis, and intralumenal protrusion of endothelial cells, as well as swollen basement and highly flexed and discontinued elastic plate. In the tunicae media, vacuolization and swollen mitochondria were found in muscular cells. In the tunicae adventitia, extravascular erythrocytes, edema or apoptosis of pericytes, collagen predominance, and inflammatory cell infiltration and destruction were found. Neuron denature and necrosis were found in the peripheral brain tissue. In the microvascular structure of 5 glioma specimens, we found enlargement and hyperplasia of endothelial cells, swollen basement membrane, swollen pericytes, and astrocytic hyperplasia and neuron denature in adjacent brain tissues. Our findings provide strong evidence for the hypothesis that intracystic or pericystic vascular degeneration or destruction accounts for the spontaneous hemorrhage tendency before and after surgical resection of ECs. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Control of stored product pests by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Hallman, Guy J [United States Department of Agriculture, Agricultural Research Service, Weslaco, TX (United States)

    2013-01-15

    Food irradiation for prevention of food-borne illness and disinfestation of commodities of pests is increasing in a number of countries. The goal of this review is to analyze the literature and current use of irradiation to control stored product pests and suggest research to optimize its potential. Doses to prevent reproduction of stored product pests range from 0.05 kGy for Tenebrio molitor L. to 0.45 kGy for Sitotroga cereallela (Olivier). Small but increasing amounts of grains and pulses are being irradiated in the world today especially in Asia. At least 33 countries permit irradiation of some stored products with 14 countries permitting it for all stored products. Ways in which stored product irradiation research and application may influence other uses of irradiation technology are also discussed. Deactivation of weed seeds might be an area of stored product phytosanitation where irradiation would have an advantage over other measures. (author)

  9. Stored energy recovery of irradiated copper

    International Nuclear Information System (INIS)

    Richard, R.T.; Chaplin, R.L.; Coltman, R.R. Jr.; Kerchner, H.R.; Klabunde, C.E.

    1990-01-01

    The stored energy released in Stage I recovery of reactor neutron irradiated copper was measured by differential thermal analysis calorimetry for three fluences up to a maximum of 3.5 x 10 18 n/cm 2 (E>0.1 MeV) after irradiation at temperatures of less than 10 K. The dependence of the stored energy upon fluence, and a tendency toward saturation, were observed. Theoretical reaction rate processes were compared directly with the experimental rates of stored energy release, and the parameters associated with the theory were compared with results from previous resistivity measurements. Good agreement was found for several parameters, but major differences with previous D + E substage results lead to the conclusion that the point defect model may not describe materials experiencing severe neutron damage. Computer studies of warmup rates were made for first and second order and for correlated recovery processes as a function of defect concentration and of external power input. First and second order processes show definite distortion in their recovery rate curves for high defect concentrations; the correlated recovery process shows a much less pronounced effect. This investigation of stored energy used several new approaches. The use of induced radioactivity within the sample as the heating source, and the use of computer generated theoretical stored energy release curves to analyze the data were unique. (author)

  10. Shielding required for radiation produced by 15 GeV stored electrons

    International Nuclear Information System (INIS)

    Jenkins, T.M.; McCaslin, J.B.; Thomas, R.H.

    1974-01-01

    The first phase of PEP will consist of a 15 GeV electron and positron storage ring. This note examines the shielding required by such a facility. Shielding of neutrons and muons produced by 200 GeV protons in the second phase of PEP has been discussed in previous notes. 9 refs., 9 figs., 5 tabs

  11. Customers' willingness to purchase new store brands

    OpenAIRE

    Zielke, Stephan; Dobbelstein, Thomas

    2007-01-01

    Purpose – The purpose of this paper is to identify factors influencing customers’ willingness to purchase new store brands. Design/methodology/approach – The paper develops a 3 £ 3 design to investigate the impact of price and quality positioning on the willingness to purchase new store brands in five product groups. A total of 990 respondents completed a questionnaire about store brand perception, aspects of purchasing behavior and willingness to buy. Data are analyzed with analysis...

  12. Pressure Systems Stored-Energy Threshold Risk Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Paulsen, Samuel S.

    2009-08-25

    Federal Regulation 10 CFR 851, which became effective February 2007, brought to light potential weaknesses regarding the Pressure Safety Program at the Pacific Northwest National Laboratory (PNNL). The definition of a pressure system in 10 CFR 851 does not contain a limit based upon pressure or any other criteria. Therefore, the need for a method to determine an appropriate risk-based hazard level for pressure safety was identified. The Laboratory has historically used a stored energy of 1000 lbf-ft to define a pressure hazard; however, an analytical basis for this value had not been documented. This document establishes the technical basis by evaluating the use of stored energy as an appropriate criterion to establish a pressure hazard, exploring a suitable risk threshold for pressure hazards, and reviewing the methods used to determine stored energy. The literature review and technical analysis concludes the use of stored energy as a method for determining a potential risk, the 1000 lbf-ft threshold, and the methods used by PNNL to calculate stored energy are all appropriate. Recommendations for further program improvements are also discussed

  13. Method for storing radioactive rare gases

    International Nuclear Information System (INIS)

    Watabe, Atsushi; Nagao, Hiroyuki; Takiguchi, Yukio; Kanazawa, Toshio; Soya, Masataka.

    1975-01-01

    Object: To safely and securely store radioactive rare gases for a long period of time. Structure: The waste gases produced in nuclear power plant are cooled by a cooler and then introduced into a low temperature adsorbing device so that the gases are adsorbed by adsorbents, and then discharged into atmosphere through the purifying gas discharge line. When the radioactive rare gases reach a level of saturation in the amount of adsorption, they are heated and extracted by a suction pump and heated by a heater. The gases are then introduced into an oxygen-impurity removing device and the purified rare gases containing no oxygen and impurities are cooled by a cooler and fed into a gas holder. When the amount of radioactive rare gases stored within the gas holder reaches a given level, they are compressed and sealed by a compressure into a storing cylinder and residual gases in the piping are sucked and recovered into the gas holder, after which the cylinder is removed and stored in a fixed room. (Kamimura, M.)

  14. Walmart Experimental Store Performance Stories: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Kozubal, E.; Norton, P.

    2010-08-01

    Walmart opened two experimental stores--one in Colorado and one in Texas--in 2005 to serve as test beds for several advanced building systems. Each embodied more than 50 experiments covering materials, water systems, energy systems, and renewable energy production. Walmart worked for three years with the National Renewable Energy Laboratory for the Colorado Store and Oak Ridge National Laboratory for the Texas store to monitor, analyze, and report on their performance. HVAC experiments included waste oil boilers, a microturbine/absorption chiller combined heat and power system, evaporative cooling, and a transpired solar collector. The refrigeration systems integrated a medium-temperature secondary loop, evaporatively cooled condenser, doors on medium-temperature cases, and light-emitting diodes on cases. Experiments in the lighting systems included a redesigned roof for clerestory daylighting and T-5 fluorescent lamps. Three photovoltaic systems for a total of 135 kW and a 50-kW wind turbine are also included. The energy system performance was compared to the measured performance of a prototypical Walmart store and to other benchmarks.

  15. Current Knowledge and Practice of Pediatric Providers in Umbilical Cord Blood Banking.

    Science.gov (United States)

    Armstrong, Amy E; Fonstad, Rachel; Spellman, Stephen; Tullius, Zoe; Chaudhury, Sonali

    2018-02-01

    More than 35 000 umbilical cord blood (UCB) transplants have been performed worldwide, prompting the development of private and public banks to collect and store UCB cells. We hypothesized that pediatricians, who are uniquely poised to discuss UCB banking (UCBB) during prenatal or sibling visits, rarely do so. Through distribution of a 26-question electronic survey to general and subspecialty pediatric providers, we assessed baseline knowledge and conversations about UCBB. A total of 473 providers completed the survey; only 22% of physicians ever discussed UCBB with expectant parents. The majority responded that autologous UCB transplants were indicated in malignant (73%) and nonmalignant (61%) conditions; however, these are rare indications. Providers practicing >10 years were more likely to address UCBB ( P ≤ .001), whereas younger and female general pediatric providers were significantly less likely ( P < .001). Overall, pediatric providers rarely speak to families about UCBB, and we believe that they can be better informed to its current clinical utility.

  16. Blood banking-induced alteration of red blood cell oxygen release ability.

    Science.gov (United States)

    Li, Yaojin; Xiong, Yanlian; Wang, Ruofeng; Tang, Fuzhou; Wang, Xiang

    2016-05-01

    Current blood banking procedures may not fully preserve red blood cell (RBC) function during storage, contributing to the decrease of RBC oxygen release ability. This study was undertaken to evaluate the impact of routine cold storage on RBC oxygen release ability. RBC units were collected from healthy donors and each unit was split into two parts (whole blood and suspended RBC) to exclude possible donor variability. Oxygen dissociation measurements were performed on blood units stored at 4 °C during a 5-week period. 2,3-diphosphoglycerate levels and fluorescent micrographs of erythrocyte band 3 were also analysed. P50 and oxygen release capacity decreased rapidly during the first 3 weeks, and then did not change significantly. In contrast, the kinetic properties (PO2-t curve and T*50) of oxygen release changed slowly during the first 3 weeks of storage, but then decreased significantly in the last 2 weeks. 2,3-diphosphoglycerate decreased quickly during the first 3 weeks of storage to almost undetectable levels. Band 3 aggregated significantly during the last 2 weeks of storage. RBC oxygen release ability appears to be sensitive to routine cold storage. The thermodynamic characteristics of RBC oxygen release ability changed mainly in the first 3 weeks of storage, due to the decrease of 2,3-diphosphoglycerate, whereas the kinetic characteristics of RBC oxygen release ability decreased significantly at the end of storage, probably affected by alterations of band 3.

  17. Evaluation of dry blood spot technique for quantification of an Anti-CD20 monoclonal antibody drug in human blood samples.

    Science.gov (United States)

    Lin, Yong-Qing; Zhang, Yilu; Li, Connie; Li, Louis; Zhang, Kelley; Li, Shawn

    2012-01-01

    To evaluate the dried blood spot (DBS) technique in ELISA quantification of larger biomolecular drugs, an anti-CD20 monoclonal antibody drug was used as an example. A method for the quantification of the anti-CD20 drug in human DBS was developed and validated. The drug standard and quality control samples prepared in fresh human blood were spotted on DBS cards and then extracted. A luminescent ELISA was used for quantification of the drug from DBS samples. The assay range of the anti-CD20 drug standards in DBS was 100-2500ng/mL. The intra-assay precision (%CV) ranged from 0.4% to 10.1%, and the accuracy (%Recovery) ranged from 77.9% to 113.9%. The inter assay precision (%CV) ranged from 5.9% to 17.4%, and the accuracy ranged from 81.5% to 110.5%. The DBS samples diluted 500 and 50-fold yielded recovery of 88.7% and 90.7%, respectively. The preparation of DBS in higher and lower hematocrit (53% and 35%) conditions did not affect the recovery of the drug. Furthermore, the storage stability of the anti-CD20 drug on DBS cards was tested at various conditions. It was found that the anti-CD20 drug was stable for one week in DBS stored at room temperature. However, it was determined that the stability was compro]mised in DBS stored at high humidity, high temperature (55°C), and exposed to direct daylight for a week, as well as for samples stored at room temperature and high humidity conditions for a month. Stability did not change significantly in samples that underwent 3 freeze/thaw cycles. Our results demonstrated a successful use of DBS technique in ELISA quantification of an anti-CD20 monoclonal antibody drug in human blood. The stability data provides information regarding sample storage and shipping for future clinical studies. It is, therefore, concluded that the DBS technique is applicable in the quantification of other large biomolecule drugs or biomarkers. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Post-harvest Quality Evaluation of Grapes using Non-destructive Electronic Nose

    Directory of Open Access Journals (Sweden)

    RAJIN S. M. Ataul Karim

    2015-10-01

    Full Text Available Over the past decades, electronic nose has opened a variety of possibilities and is becoming one of the most important non-destructive odour inspection technologies in the food industry. The objective of this study is to determine the quality degradation of the fruit by monitoring the change in the volatile compound while kept in storage using a lab manufactured electronic nose. Here, grapes are chosen as the fruit sample for experiment. Principal component analysis (PCA is used to determine the ability of the electronic nose to distinguish the different quality of the fruit stored over an interval of time. The result shows that using PCA analysis, the electronic nose is able to identify a clear distinction between the aromas of grapes stored for different time intervals.

  19. Method of storing solidification products

    International Nuclear Information System (INIS)

    Tani, Yutaro.

    1985-01-01

    Purpose: To enable to efficiently and satisfactorily cool and store solidification products of liquid wastes generated from the reactor spent fuel reprocessing process by a simple facility. Method: Liquid wastes generated from the reactor spent fuel reprocessing process are caused to flow from the upper opening to the inside of a spherical canistor. The opening of the spherical canistor is welded with a lid by a remote control and the liquid wastes are tightly sealed within the spherical canistor as glass solidification products. Spherical canistors having the solidification products tightly sealed therein are sent into and stored in a hopper by the remote control. Further, a blower is driven upon storing to suck cooling air from the cooling air intake port to the inside of the hopper to absorb the decay heat of radioactive materials in the solidification products and the air is discharged from the duct and through the stack to the atmosphere. (Kawakami, Y.)

  20. Performance Determinants for Convenience Store Suppliers

    OpenAIRE

    Zainah Abdullah; Aznur Hajar Abdullah

    2012-01-01

    This paper examines the impact of information and communication technology (ICT) usage, internal relationship, supplier-retailer relationship, logistics services and inventory management on convenience store suppliers- performance. Data was collected from 275 convenience store managers in Malaysia using a set of questionnaire. The multiple linear regression results indicate that inventory management, supplier-retailer relationship, logistics services and internal relation...

  1. Apparatus and method for monitoring stored material

    International Nuclear Information System (INIS)

    Price, W.E.; Lewis, D.R.; Galloway, L.A.; Lowrey, C.B.

    1983-01-01

    Material, e.g. radioactive waste or other hazardous material, which is to be stored and monitored is placed within the innermost container of a series of nested containers and monitoring fluids are circulated in a closed loop of fluid flow through the spaces between the nested containers. Monitoring devices are used to analyse said monitoring fluids to detect leakage of the stored material from the innermost nested container and to detect the migration of external fluids into the series of nested containers. A computer based monitoring system continually checks the values of various parameters of the monitoring fluids to immediately detect and report the presence of stored material or external fluid in the monitoring fluids. The stored material may then be immediately retrieved from storage to repair leaks in the series of nested containers. (author)

  2. Chagas disease vector blood meal sources identified by protein mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Judith I Keller

    Full Text Available Chagas disease is a complex vector borne parasitic disease involving blood feeding Triatominae (Hemiptera: Reduviidae insects, also known as kissing bugs, and the vertebrates they feed on. This disease has tremendous impacts on millions of people and is a global health problem. The etiological agent of Chagas disease, Trypanosoma cruzi (Kinetoplastea: Trypanosomatida: Trypanosomatidae, is deposited on the mammalian host in the insect's feces during a blood meal, and enters the host's blood stream through mucous membranes or a break in the skin. Identifying the blood meal sources of triatomine vectors is critical in understanding Chagas disease transmission dynamics, can lead to identification of other vertebrates important in the transmission cycle, and aids management decisions. The latter is particularly important as there is little in the way of effective therapeutics for Chagas disease. Several techniques, mostly DNA-based, are available for blood meal identification. However, further methods are needed, particularly when sample conditions lead to low-quality DNA or to assess the risk of human cross-contamination. We demonstrate a proteomics-based approach, using liquid chromatography tandem mass spectrometry (LC-MS/MS to identify host-specific hemoglobin peptides for blood meal identification in mouse blood control samples and apply LC-MS/MS for the first time to Triatoma dimidiata insect vectors, tracing blood sources to species. In contrast to most proteins, hemoglobin, stabilized by iron, is incredibly stable even being preserved through geologic time. We compared blood stored with and without an anticoagulant and examined field-collected insect specimens stored in suboptimal conditions such as at room temperature for long periods of time. To our knowledge, this is the first study using LC-MS/MS on field-collected arthropod disease vectors to identify blood meal composition, and where blood meal identification was confirmed with more

  3. Pregnant women's knowledge and attitudes about stem cells and cord blood banking.

    Science.gov (United States)

    Dinç, H; Sahin, N H

    2009-06-01

    This study was to determine pregnant women's knowledge and attitudes towards stem cells and cord blood banking in Istanbul, Turkey. Stem cell research is one of the most important and, at the same time, the most controversial topics of science and technology today. Nurses need to understand stem cell research so they can enter the debate on this issue. They can become important sources of information in order to help parents understand the issues. This exploratory descriptive study was conducted in two antenatal outpatient clinics in Istanbul. The sample consisted of 334 pregnant women during routine prenatal visits. Data were collected in interviews by using an interview form developed by the researchers according to the literature. The form included demographic characteristics of participants and 20 questions about stem cells, storing cord blood and banking and 10 independent attitude statements. The majority of the participants had a lack of knowledge about stem cells and cord blood banking and wanted more information. Before pregnancy, they received some information through the media (newspaper, Internet, television, etc.), but unintentionally. It was determined that they wanted information before becoming pregnant, more from their obstetrician but also from nurses and midwives. The majority also wanted to store their infants' cord blood and stated that they would be more likely to choose a public cord blood bank. Those giving ante- and perinatal care need to offer accurate and scientific counselling services on this subject to parents who need to be informed.

  4. Umbilical cord blood donation: public or private?

    Science.gov (United States)

    Ballen, K K; Verter, F; Kurtzberg, J

    2015-10-01

    Umbilical cord blood (UCB) is a graft source for patients with malignant or genetic diseases who can be cured by allogeneic hematopoietic cell transplantation (HCT), but who do not have an appropriately HLA-matched family or volunteer unrelated adult donor. Starting in the 1990s, unrelated UCB banks were established, accepting donations from term deliveries and storing UCB units for public use. An estimated 730 000 UCB units have been donated and stored to date and ~35 000 UCB transplants have been performed worldwide. Over the past 20 years, private and family banks have grown rapidly, storing ~4 million UCB units for a particular patient or family, usually charging an up-front and yearly storage fee; therefore, these banks are able to be financially sustainable without releasing UCB units. Private banks are not obligated to fulfill the same regulatory requirements of the public banks. The public banks have released ~30 times more UCB units for therapy. Some countries have transitioned to an integrated banking model, a hybrid of public and family banking. Today, pregnant women, their families, obstetrical providers and pediatricians are faced with multiple choices about the disposition of their newborn's cord blood. In this commentary, we review the progress of UCB banking technology; we also analyze the current data on pediatric and adult unrelated UCB, including the recent expansion of interest in transplantation for hemoglobinopathies, and discuss emerging studies on the use of autologous UCB for neurologic diseases and regenerative medicine. We will review worldwide approaches to UCB banking, ethical considerations, criteria for public and family banking, integrated banking ideas and future strategies for UCB banking.

  5. Changes in electrolytes and blood gas after transfusion of irradiated MAP

    International Nuclear Information System (INIS)

    Miyao, Hideki; Katayama, Akinori; Okamoto, Yumi; Koyama, Kaoru; Kawasaki, Jun; Kawazoe, Taro

    2001-01-01

    This study was undertaken to investigate the changes in recipient serum electrolytes and arterial blood gas after irradiated blood transfusion. We measured electrolytes and arterial blood gas before and after the transfusion during elective surgery in 55 patients. The mean blood loss was 1,477 g and the mean transfused blood unit of irradiated Mannitol-Adenine-Phosphate (MAP) was 5.9 units. Potassium concentration increased from 3.8 to 4.2 mEq·l -1 . A total of 187 units, which had been stored for 12.3±3.5 days after donation and for 5.1±3.8 days after irradiation, was used. There was a significant correlation between the storage period from the day of irradiation and the potassium concentration of the supernatant (r=0.56, p<0.0001). This study recommends that a safe transfusion rate of irradiated blood should be determined because the high potassium concentration of irradiated blood may lead to lethal complications in case of rapid transfusion. (author)

  6. Extension technology of store ability of spent fuel

    International Nuclear Information System (INIS)

    1991-05-01

    It is the introduction of the extension technology of store ability of spent fuel including metal store cask, transport and store cask, concrete cask, NUHOMS and MVDS. It explains of technology of recombination of spent fuel including the purpose and real application, demonstration, presumption of expense, major interesting issue and the present condition of relevant licences permit and approvals.

  7. Electronic remote blood issue combined with a computer-controlled, automated refrigerator for major surgery in operating theatres at a distance from the transfusion service.

    Science.gov (United States)

    Verlicchi, Franco; Pacilli, Pasqua; Bragliani, Arianna; Rapuano, Silvia; Dini, Daniele; Vincenzi, Daniele

    2018-02-01

    The difficulty of supplying red blood cells within an adequate time to patients undergoing surgery is a known problem for transfusion services, particularly if the operating theater is located at some distance from the blood bank. The consequences frequently are that more blood is ordered than required; several units are allocated and issued; and unused units must be returned to the blood bank. Some sparse reports have demonstrated that remote blood issue systems can improve the efficiency of issuing blood. This study describes a computer-controlled, self-service, remote blood-release system, combined with an automated refrigerator, installed in a hospital at which major surgery was performed, located 5 kilometers away from the transfusion service. With this system, red blood cell units were electronically allocated to patients immediately before release, when the units actually were needed. Two 2-year periods, before and after implementation of the system, were compared. After implementation of the system, the ratio of red blood cell units returned to the transfusion service was reduced from 48.9% to 1.6% of the issued units (8852 of 18,090 vs. 182 of 11,152 units; p blood cell units was observed, probably mainly due to changes in the number and complexity of surgical procedures. No transfusion errors occurred in the two periods. The current results demonstrate that the remote blood-release system is safe and useful for improving the efficiency of blood issue for patients in remote operating theatres. © 2017 AABB.

  8. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test acknow...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  9. The effects of storage temperature and duration of blood samples on DNA and RNA qualities.

    Science.gov (United States)

    Huang, Lien-Hung; Lin, Pei-Hsien; Tsai, Kuo-Wang; Wang, Liang-Jen; Huang, Ying-Hsien; Kuo, Ho-Chang; Li, Sung-Chou

    2017-01-01

    DNA and RNA samples from blood are the common examination target for non-invasive physical tests and/or biomedical studies. Since high-quality DNA and RNA samples guarantee the correctness of these tests and/or studies, we investigated the effects of storage temperature and storage duration of whole blood on DNA and RNA qualities. Subjects were enrolled to donate blood samples which were stored for different durations and at different temperatures, followed by the examinations on RNA quality, qPCR, DNA quality and DNA methylation. For RNA, we observed obvious quality decline with storage duration longer than 24 hours. Storage at low temperature does not keep RNA samples from degradation. And, storing whole blood samples in freezer dramatically damage RNA. For DNA, quality decline was not observed even with storage duration for 15 days. However, DNA methylation significantly altered with storage duration longer than three days. Storage duration within 24 hours is critical for collecting high-quality RNA samples for next-generation sequencing (NGS) assays (RIN≧8). If microarray assays are expected (RIN≧7), storage duration within 32 hours is acceptable. Although DNA is resistant within 15 days when kept in whole blood, DNA quantity dramatically decreases owing to WBC lysis. In addition, duration for more than three days significantly alter DNA methylation status, globally and locally. Our result provides a reference for dealing with blood samples.

  10. Empirical Study of Consumers' Purchase Intentions in C2C Electronic Commerce

    Institute of Scientific and Technical Information of China (English)

    HE Dehua; LU Yaobin; ZHOU Deyi

    2008-01-01

    Electronic commerce is becoming increasingly important in business, but lack of intention to purchase has become a main barrier in the development of electronic commerce. Thus, effective measures are needed to promote consumers' intentions to purchase in online consumer to consumer (C2C) stores. This paper postulates that five factors, the perceived ease of use of the website, perceived usefulness of the website, vendor competence, introduction and recommendations of third parties, and vendors' attitude toward customers, influence consumers' intentions to purchase in online C2C stores and this intention directly leads to their action to purchase from online C2C stores. The structural equation modeling (SEM) method was used to analyze empirical data, supporting these hypotheses except for the effect of vendor competence.

  11. Peranan Store Atmosphere Dalam Meningkatkan Keputusan Pembelian

    Directory of Open Access Journals (Sweden)

    Rennyta Yusiana

    2017-04-01

    ABSTRACT Bandung is a destination for domestic and foreign tourists with culinary goals. There are many restaurants and cafes offering a variety of culinary tastes, ranging from culinary archipelago to abroad. Nowadays consumers are attracted to the restaurant and cafe with a different atmosphere. One of them is the Hummingbird Eatery which implementing store homey atmosphere, with the cozy interior and dominated by furniture made of wood. Atmosphere is an important factor for consumers in choosing where to dine and relax. Cozy atmosphere with unique decor and creative appeal to a restaurant that makes consumers visit. This study aims to determine consumer response regarding the role of Store Atmosphere in increasing consumer purchasing decisions. This type of research is descriptive and quantitative, using 100 samples. Data collection techniques used were questionnaires, observations, interviews, and literature studies. This study uses SPSS V.22 and simple linear regression. The results of this study indicate that the general interior becomes a major consideration as a benefit for consumers in making purchasing decisions apart from other sub variables store atmosphere. Managers can prioritize managing general interior more effectively, because consumers prefer it in the store atmosphere. Keywords: Store Atmosphere, Purchase Decision

  12. Relationship between Serum Iron Profile and Blood Groups among the Voluntary Blood Donors of Bangladesh.

    Science.gov (United States)

    Hoque, M M; Adnan, S D; Karim, S; Al-Mamun, M A; Faruki, M A; Islam, K; Nandy, S

    2016-04-01

    Blood donation results in a substantial iron loss and subsequent mobilization from body stores. Chronic iron deficiency is a well-recognized complication of regular blood donation. The present study conducted to compare the level of serum ferritin, serum iron, total iron binding capacity (TIBC) and percentage transferrin saturation in different ABO and Rhesus type blood groups among the voluntary blood donors of Bangladesh. The present prospective study included 100 healthy voluntary donors attending at Department of Blood Transfusion, Dhaka Medical College, Dhaka between the periods of July 2013 to Jun 2014. From each donor 10mL venous blood sample was taken and divided into heparinized and non-heparinized tubes for determination of hemoglobin (Hb), hematocrit (Hct), serum iron (SI), total iron binding capacity (TIBC) and serum ferritin by standard laboratory methods. Percentage of transferrin saturation (TS) calculated from serum iron and TIBC. Data were analyzed with SPSS (version 16) software and comparisons between groups were made using student's t-test and one way ANOVA. In the present study mean±SD of age of the respondents was 27.2±6.5 years with a range of 18 to 49 years and 81.0% were male and 19.0% were female. Among the donors 18.0% had blood group A, 35.0% had blood group B, 14.0% had blood group AB and 33.0% had blood group O. Among the donors 91.0% had rhesus positive and 9.0% had rhesus negative. Donors with blood group O had lowest haemoglobin, serum iron and transferring saturation levels. Donors with blood group A had highest TIBC level. Donors with blood group B had lowest serum ferritin level. An independent samples 't' test showed statistically significant difference in serum ferritin and percentage transferrin saturation between blood group AB and blood group O and in percentage transferrin saturation between blood group B and blood group O. One way ANOVA showed that there is no significant difference in haemoglobin, serum iron, serum

  13. Design variables and constraints in fashion store design processes

    DEFF Research Database (Denmark)

    Haug, Anders; Borch Münster, Mia

    2015-01-01

    is to identify the most important store design variables, organise these variables into categories, understand the design constraints between categories, and determine the most influential stakeholders. Design/methodology/approach: – Based on a discussion of existing literature, the paper defines a framework...... into categories, provides an understanding of constraints between categories of variables, and identifies the most influential stakeholders. The paper demonstrates that the fashion store design task can be understood through a system perspective, implying that the store design task becomes a matter of defining......Purpose: – Several frameworks of retail store environment variables exist, but as shown by this paper, they are not particularly well-suited for supporting fashion store design processes. Thus, in order to provide an improved understanding of fashion store design, the purpose of this paper...

  14. 16-channel analog store and multiplexer unit

    Energy Technology Data Exchange (ETDEWEB)

    Brossard, M; Kulka, Z [Clermont-Ferrand-2 Univ., 63 - Aubiere (France). Lab. de Physique Corpusculaire

    1979-03-15

    A 16-channel analog store and multiplexer unit is described. The unit enables storing and selection of analog information which is then digitally encoded by single ADC. This solution becomes economically attractive particularly in multidetector pulse height analysis systems.

  15. Red blood cells, still vital after all these years: Commentary on Canadian Blood Services' International Symposium 2017.

    Science.gov (United States)

    Qadri, Syed M; Donkor, David A; Yan, Matthew; Ning, Shuoyan; Branch, Donald R; Seghatchian, Jerard; Sheffield, William P

    2018-04-01

    Canadian Blood Services (CBS), Canada's national blood transfusion service, has for many years sponsored an annual conference, for the education and awareness of interested participants, showcasing the latest evidence-based understanding of both basic science and clinical issues in transfusion medicine and science. The 15th iteration of this symposium took place September 9, 2017 and focused on some of the vital aspects of red blood cells (RBC), in line with the" 3Rs" concept, namely the provision of the Right red blood cell (RBC) product to the Right patient at the Right time. Presentations touched upon: the evolution of blood banking in North America; the monocyte monolayer assay as a predictor of post-transfusion hemolysis; hemoglobin-based oxygen carriers; RBC alloimmunization; serological approaches to complex RBC antibody problems; randomized clinical trials related to the age of stored RBC; RBC genotyping; pathophysiology, prevention and treatment of hemolytic disease of the fetus and newborn (HDFN); and testing and timing in perinatal serology. This commentary provides summaries of all speakers' presentations annotated with relevant references. Special thanks are due to all contributors for their praiseworthy approaches in sharing their experiences and knowledge on this interesting scientific/clinical and management theme. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Blood lead levels and bone turnover with weight reduction in women

    OpenAIRE

    RIEDT, CLAUDIA S.; BUCKLEY, BRIAN T.; BROLIN, ROBERT E.; AMBIA-SOBHAN, HASINA; RHOADS, GEORGE G.; SHAPSES, SUE A.

    2008-01-01

    High bone turnover states are known to raise blood lead levels (BPb). Caloric restriction will increase bone turnover, yet it remains unknown if weight reduction increases BPb due to mobilization of skeletal stores. We measured whole blood Pb levels (206Pb) by inductively coupled plasma mass spectrometry in 73 women (age 24–75 years; BMI 23– 61 kg/m2) before and after 6 months of severe weight loss (S-WL), moderate weight loss (M-WL), or weight maintenance (WM). Baseline BPb levels were relat...

  17. The impact of storage time of transfused blood on postoperative infectious complications in rectal cancer surgery. Danish RANX05 Colorectal Cancer Study Group

    DEFF Research Database (Denmark)

    Mynster, T; Nielsen, Hans Jørgen

    2000-01-01

    BACKGROUND: We have studied the impact of storage time of transfused allogeneic blood together with other known risk factors on postoperative infectious complications after operation for rectal cancer. METHODS: Intra-abdominal abscess, anastomotic leakage, septicaemia, wound infection...... and storage time of saline-adenine-glucose-mannitol (SAGM) blood, administered to each patient, were recorded retrospectively. RESULTS: The overall infection rate was 24% in 78 non-transfused and 40% in 225 transfused patients (P = 0.011). The proportion of SAGM blood stored for > or = 21 days administered...... to each transfused patient was a median of 60% in patients developing postoperative infections versus 25% (P = 0.037) in patients without infections. A multivariate analysis of significant risk variables showed weight > 75 kg (odds ratio, 2.0 versus transfusion of SAGM blood stored > or = 21...

  18. [Allogenic hematopoietic stem cell transplantation with unrelated cord blood: report of three cases from the Chilean cord blood bank].

    Science.gov (United States)

    Barriga, Francisco; Wietstruck, Angélica; Rojas, Nicolás; Bertin, Pablo; Pizarro, Isabel; Carmona, Amanda; Guilof, Alejandro; Rojas, Iván; Oyarzún, Enrique

    2013-08-01

    Public cord blood banks are a source of hematopoietic stem cells for patients with hematological diseases who lack a family donor and need allogeneic transplantation. In June 2007 we started a cord blood bank with units donated in three maternity wards in Santiago, Chile. We report the first three transplants done with cord blood units form this bank. Cord blood units were obtained by intrauterine collection at delivery. They were depleted of plasma and red cells and frozen in liquid nitrogen. Tests for total nucleated cells, CD34 cell content, viral serology, bacterial cultures and HLA A, B and DRB1 were done. Six hundred cord blood units were stored by March 2012. Three patients received allogeneic transplant with cord blood from our bank, two with high risk lymphoblastic leukemia and one with severe congenital anemia. They received conditioning regimens according to their disease and usual supportive care for unrelated donor transplantation until full hematopoietic and immune reconstitution was achieved. The three patients had early engraftment of neutrophils and platelets. The child corrected his anemia and the leukemia patients remain in complete remission. The post-transplant course was complicated with Epstein Barr virus, cytomegalovirus and BK virus infection. Two patients are fully functional 24 and 33 months after transplant, the third is still receiving immunosuppression.

  19. Storing empty calories and chronic disease risk: snack-food products, nutritive content, and manufacturers in Philadelphia corner stores.

    Science.gov (United States)

    Lucan, Sean C; Karpyn, Allison; Sherman, Sandy

    2010-05-01

    Corner stores are part of the urban food environment that may contribute to obesity and diet-related diseases, particularly for low-income and minority children. The snack foods available in corner stores may be a particularly important aspect of an urban child's food environment. Unfortunately, there is little data on exactly what snack foods corner stores stock, or where these foods come from. We evaluated snack foods in 17 Philadelphia corner stores, located in three ethnically distinct, low-income school neighborhoods. We recorded the manufacturer, calories, fat, sugar, and sodium for all snack items, excluding candy and prepared foods. We then compared the nutritive content of assessed snack items to established dietary recommendations and a school nutrition standard. In total, stores stocked 452 kinds of snacks, with only 15% of items common between all three neighborhoods. Total and unique snacks and snack food manufacturers varied by neighborhood, but distributions in snack type varied negligibly: overall, there were no fruit snacks, no vegetable snacks, and only 3.6% of all snacks (by liberal definition) were whole grain. The remainder (96.4% of snacks) was highly processed foods. Five of 65 manufacturers supplied 73.4% of all kinds of snack foods. Depending on serving size definition, 80.0-91.5% of snack foods were "unhealthy" (by the school nutrition standard), including seven of 11 wholegrain products. A single snack item could supply 6-14% of a day's recommended calories, fat, sugar, and sodium on average (or 56-169% at the extreme) for a "typical" child. We conclude that corner store snack food inventories are almost entirely unhealthful, and we discuss possible implications and next steps for research and intervention.

  20. The hematocrit paradox--how does blood doping really work?

    Science.gov (United States)

    Böning, D; Maassen, N; Pries, A

    2011-04-01

    The wide-spread assumption that doping with erythropoietin or blood transfusion is only effective by increasing arterial blood O2 content because of rising hematocrit is not self-evident. "Natural blood dopers" (horses, dogs) increase both hematocrit and circulating blood volume during exercise by releasing stored erythrocytes from the spleen. Improvement of aerobic performance by augmenting hemoglobin concentration may be expected until the optimal hematocrit is reached; above this value maximal cardiac output declines due to the steep increase of blood viscosity. Therefore an enlarged blood oxygen content might only be useful if the normal hematocrit of man during exercise is suboptimal. However, recent studies suggest that cardiac power rises after erythropoietin allowing an unchanged cardiac output in spite of increased viscosity. Other factors underlying improved performance after blood doping might be: augmented diffusion capacity for oxygen in lungs and tissues, increased percentage of young red cells with good functional properties (after erythropoietin), increased buffer capacity, increase of blood volume, vasoconstriction, reduced damage by radicals, mood improvement by cerebral effects of erythropoietin. Also the importance of placebo is unknown since double-blind studies are rare. It is suggested that blood doping has multifactorial effects not restricted to the increase in arterial oxygen content. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Conditional load and store in a shared memory

    Science.gov (United States)

    Blumrich, Matthias A; Ohmacht, Martin

    2015-02-03

    A method, system and computer program product for implementing load-reserve and store-conditional instructions in a multi-processor computing system. The computing system includes a multitude of processor units and a shared memory cache, and each of the processor units has access to the memory cache. In one embodiment, the method comprises providing the memory cache with a series of reservation registers, and storing in these registers addresses reserved in the memory cache for the processor units as a result of issuing load-reserve requests. In this embodiment, when one of the processor units makes a request to store data in the memory cache using a store-conditional request, the reservation registers are checked to determine if an address in the memory cache is reserved for that processor unit. If an address in the memory cache is reserved for that processor, the data are stored at this address.

  2. Point-of-Sale E-cigarette Advertising Among Tobacco Stores.

    Science.gov (United States)

    Wan, Neng; Siahpush, Mohammad; Shaikh, Raees A; McCarthy, Molly; Ramos, Athena; Correa, Antonia

    2017-12-01

    The marketing expenditure and sale of e-cigarettes increased sharply in the United States in recent years. However, little is known about neighborhood characteristics of point-of-sale (POS) e-cigarette advertising among tobacco stores. The purpose of this study was to examine socio-demographic characteristics of POS e-cigarette advertising among tobacco stores in the Omaha metropolitan area of Nebraska, USA. Between April and June 2014, trained fieldworkers completed marketing audits of all stores that sell tobacco (n = 463) in the Omaha metropolitan area and collected comprehensive e-cigarette advertising data of these stores. Based on the auditing information, we categorized tobacco stores based on e-cigarette advertising status. Logistic regression was used to examine the association between neighborhood socio-demographic factors and e-cigarette advertising among tobacco stores. 251 (54.2%) of the 463 tobacco stores had e-cigarette advertisements. We found that neighborhoods of stores with POS e-cigarette advertising had higher per capita income (p advertising. There were negative associations between e-cigarette advertising and number of adolescents or number of middle/high school students. After adjusting for covariates, only percentage of non-Hispanic Whites remained a significant factor for e-cigarette advertising. POS e-cigarette advertising among tobacco stores is related with neighborhood socioeconomic and demographic characteristics. Future studies are needed to understand how these characteristics are related with e-cigarette purchasing and e-cigarette prevalence among social groups.

  3. Investigating the effects of E-CRM's Functions on customer's E-satisfaction and E-loyalty (Case Study: Digikala Online Store

    Directory of Open Access Journals (Sweden)

    hashem aghazade

    2016-12-01

    Full Text Available Considering the importance of the factors affecting customer satisfaction and loyalty, this study aimed to investigate the relationship between performance and characteristic of a online stores – Digi-Kala in this particular case, as a perfect example of an electronic customer relationship system, and customer's electronic loyalty and satisfaction. As a practical-descriptive, research, electronic questionnaires were distributed among customers of Digikala , In which, functions of internet shopping system have been linked into three stages; before- purchase, during-purchase, after-purchase, and its relations with electronic loyalty and satisfaction have been estimated using structural -equations method. Based on the results, satisfaction of E-CRM's functions affected electronic loyalty and satisfaction. Also, satisfaction of during-purchase and after-purchase functions affected electronic satisfaction. However, the, effect of satisfaction in before-purchase functions in the electronic relation system has not been proven on satisfaction electronic customer's. Furthermore, the effect of satisfaction in system's functions in the whole stages has been proven on loyalty electronic.

  4. The novel in the electronic era? The arrival in Italy of In Cold Blood> and he very first reactions

    Directory of Open Access Journals (Sweden)

    Giulio Obici

    2014-12-01

    Full Text Available «Novel of the electronic era»: this was the definition of Truman Capote's In Cold Blood when it appeared periodically on the «New Yorker» in 1965 and then published in volume in 1966, a surprising best seller, hardly discussed, and both paradigmatic and controversial model for the so called non fiction novel. Nowadays, when we assist to a return of realism and different trends of non fiction, In Cold Blood has been quoted extensively as well as misunderstood and put together with very different texts such as Emmanuel Carrère's Adversaire di Emmanuel Carrère or Saviano's Gomorra. The further readings that we propose here might suggest a reconsideration of its interest and its innovative power; and maybe also a second reading or a very first reading.

  5. [Effect of stress actions on some hematologic and biochemical parameters of rat blood and on energetic intermolecular interactions in lipid extract under effect of light radiation].

    Science.gov (United States)

    Zabelinskiĭ, S A; Chebotareva, M A; Tavrovskaia, T V; Skverchinskaia, E A; Shukoliukova, E P; Maslov, M N; Krivchenko, A I

    2012-01-01

    Comparative study has been carried of effect of the three-day long starvation, running, and their combination on morphological parameters of rat blood, lipid metabolism, and activity of blood Na,K-ATPase. Different effect has been shown of these stress factors on the blood erythrocyte composition. Starvation is accompanied by the most pronounced release of stored erythrocyte into blood, which results in a significant decrease both of the total amount of reticulocytes and the complete absence of reticulocytes of the I stage of maturity (the youngest). The running on treadmill led to a significant increase of the total amount of blood reticulocytes and to multiple increase of immature reticulocytes (RC-I and RC-II), which can indicate some stress of the bone marrow erythroid stem line. The curve of acid resistance of blood reticulocytes has shown the animal to experience the greatest stress at a combination of starvation and running. Starvation and running produced different effects on blood lipid characteristics. The content of triacylglycerides (TAG) in blood rose by 40% at starvation and decreased by 30% at running, a similar tendency being found for index of atherogeneity. The fatty acid composition of blood phospholipids at running and its combination with starvation practically did not differ from control. A change of Na,K-ATPase, which is so characteristic of reaction to various kinds of stress, sharply fell at starvation (by 22%), but increased at running (by 13%) and decreased markedly at combination of these actions. Absorption spectra of lipid extracts of the whole blood of the rats submitted to various stress actions showed that extracted from blood (at different amount depending on the kind of action) is an organic substance with coupled bonds, which absorbs light in the diapason of 360-620 nm. The absorption of light in the diapason of 400-410 nm has been found to belong to the Soret band of ferroheme and ferriheme. The shift of the Soret band indicates

  6. [Scanning electron microscopy of peripheral blood erythrocytes in the diagnosis and treatment of hemorrhagic vasculitis in children].

    Science.gov (United States)

    Nagaeva, T A; Balasheva, I I; Saratikov, A S; Bocharova, M N; Mikhalenko, A N

    2001-01-01

    Twenty-four children aged 3-15 years were examined, 16 of these with cutaneous and articulo-cutaneous hemorrhagic vasculitis (HV) and 8 normal controls. The patients were divided into 2 groups: 10 patients treated by basic therapy and 6 children whose treatment protocols were supplemented by membranoprotector locheine. The children were repeatedly examined 1 month after discharge from hospital. Scanning electron microscopy of peripheral blood erythrocytes provides valuable diagnostic data on erythrocyte membrane morphology and function in children with HV and can serve as a method for monitoring the efficiency of new approaches to therapy of this disease.

  7. Understanding Consumers' In-store Visual Perception

    DEFF Research Database (Denmark)

    Clement, Jesper; Kristensen, Tore; Grønhaug, Kjell

    2013-01-01

    It is widely accepted that the human brain has limited capacity for perceptual stimuli and consumers'' visual attention, when searching for a particular product or brand in a grocery store, should then be limited by the boundaries of their own perceptual capacity. In this exploratory study, we...... examine the relationship between abundant in-store stimuli and limited human perceptual capacity. Specifically, we test the influence of package design features on visual attention. Data was collected through two eye-tracking experiments, one in a grocery store using wireless eye-tracking equipment......, and another in a lab setting. Findings show that consumers have fragmented visual attention during grocery shopping, and that their visual attention is simultaneously influenced and disrupted by the shelf display. Physical design features such as shape and contrast dominate the initial phase of searching...

  8. Development and reliability testing of a food store observation form.

    Science.gov (United States)

    Rimkus, Leah; Powell, Lisa M; Zenk, Shannon N; Han, Euna; Ohri-Vachaspati, Punam; Pugach, Oksana; Barker, Dianne C; Resnick, Elissa A; Quinn, Christopher M; Myllyluoma, Jaana; Chaloupka, Frank J

    2013-01-01

    To develop a reliable food store observational data collection instrument to be used for measuring product availability, pricing, and promotion. Observational data collection. A total of 120 food stores (26 supermarkets, 34 grocery stores, 54 gas/convenience stores, and 6 mass merchandise stores) in the Chicago metropolitan statistical area. Inter-rater reliability for product availability, pricing, and promotion measures on a food store observational data collection instrument. Cohen's kappa coefficient and proportion of overall agreement for dichotomous variables and intra-class correlation coefficient for continuous variables. Inter-rater reliability, as measured by average kappa coefficient, was 0.84 for food and beverage product availability measures, 0.80 for interior store characteristics, and 0.70 for exterior store characteristics. For continuous measures, average intra-class correlation coefficient was 0.82 for product pricing measures; 0.90 for counts of fresh, frozen, and canned fruit and vegetable options; and 0.85 for counts of advertisements on the store exterior and property. The vast majority of measures demonstrated substantial or almost perfect agreement. Although some items may require revision, results suggest that the instrument may be used to reliably measure the food store environment. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  9. Tirilazad mesylate protects stored erythrocytes against osmotic fragility.

    Science.gov (United States)

    Epps, D E; Knechtel, T J; Bacznskyj, O; Decker, D; Guido, D M; Buxser, S E; Mathews, W R; Buffenbarger, S L; Lutzke, B S; McCall, J M

    1994-12-01

    The hypoosmotic lysis curve of freshly collected human erythrocytes is consistent with a single Gaussian error function with a mean of 46.5 +/- 0.25 mM NaCl and a standard deviation of 5.0 +/- 0.4 mM NaCl. After extended storage of RBCs under standard blood bank conditions the lysis curve conforms to the sum of two error functions instead of a possible shift in the mean and a broadening of a single error function. Thus, two distinct sub-populations with different fragilities are present instead of a single, broadly distributed population. One population is identical to the freshly collected erythrocytes, whereas the other population consists of osmotically fragile cells. The rate of generation of the new, osmotically fragile, population of cells was used to probe the hypothesis that lipid peroxidation is responsible for the induction of membrane fragility. If it is so, then the antioxidant, tirilazad mesylate (U-74,006f), should protect against this degradation of stored erythrocytes. We found that tirilazad mesylate, at 17 microM (1.5 mol% with respect to membrane lecithin), retards significantly the formation of the osmotically fragile RBCs. Concomitantly, the concentration of free hemoglobin which accumulates during storage is markedly reduced by the drug. Since the presence of the drug also decreases the amount of F2-isoprostanes formed during the storage period, an antioxidant mechanism must be operative. These results demonstrate that tirilazad mesylate significantly decreases the number of fragile erythrocytes formed during storage in the blood bank.

  10. Consumers' store choice behavior for fresh food

    NARCIS (Netherlands)

    Meulenberg, M.T.G.; Trijp, van J.C.M.

    1991-01-01

    Consumers' preference for fresh food stores is analyzed. In particular the choice between supermarkets and specialized shops for purchasing fresh food is analyzed. Attention is given to the factors influencing this choice. For this purpose a number of research questions with respect to store choice

  11. Electron energy confinement in ELMO Bumpy Torus (EBT)

    International Nuclear Information System (INIS)

    Hiroe, S.; Haste, G.R.; Dandl, R.A.

    1979-06-01

    Using a calibrated, solid-state, soft x-ray detector, the electron temperature and density have been measured over a wide range of operating conditions of ELMO Bumpy Torus (EBT). The empirical relations of the temperature or the density to the microwave power and the ambient pressure have been determined. The toroidally stored energy has been observed to increase as the stored energy of the hot electron annulus increases. The energy confinement time has been obtained for various plasma parameters and has been found to agree with the neoclassical theory. The advantages of EBT collisionless scaling for fusion plasma confinement have been noted, i.e., n/sub e/tau/sub E/ increases as T/sub e/ 1 5 in the collisionless regime

  12. One size doesn’t fit all: Should we reconsider the introduction of cold-stored platelets in blood bank inventories? [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Alessandra Berzuini

    2017-02-01

    Full Text Available Platelet concentrates are universally prepared with a standard method and stored for 5 days at room temperature (20–24°C in gentle agitation. Currently, there is a renewed interest in the possibility of storing platelet concentrates below the standard temperatures. In fact, cold platelets might be more effective in bleeding patients and have a lower risk of bacterial transmission. Inventories including platelets at different temperatures may favour patient-centred strategies for prophylactic or therapeutic transfusions.

  13. Real-time video analysis for retail stores

    Science.gov (United States)

    Hassan, Ehtesham; Maurya, Avinash K.

    2015-03-01

    With the advancement in video processing technologies, we can capture subtle human responses in a retail store environment which play decisive role in the store management. In this paper, we present a novel surveillance video based analytic system for retail stores targeting localized and global traffic estimate. Development of an intelligent system for human traffic estimation in real-life poses a challenging problem because of the variation and noise involved. In this direction, we begin with a novel human tracking system by an intelligent combination of motion based and image level object detection. We demonstrate the initial evaluation of this approach on available standard dataset yielding promising result. Exact traffic estimate in a retail store require correct separation of customers from service providers. We present a role based human classification framework using Gaussian mixture model for this task. A novel feature descriptor named graded colour histogram is defined for object representation. Using, our role based human classification and tracking system, we have defined a novel computationally efficient framework for two types of analytics generation i.e., region specific people count and dwell-time estimation. This system has been extensively evaluated and tested on four hours of real-life video captured from a retail store.

  14. Robbery characteristics and employee injuries in convenience stores.

    Science.gov (United States)

    Faulkner, K A; Landsittel, D P; Hendricks, S A

    2001-12-01

    Each year approximately 30,000 convenience store employees are at risk for injuries related to robberies and many are fatal. A prospective cohort study of 460 convenience store robberies from 1 February 1995 to 30 September 1996 was conducted to uncover possible associations between injury and pertinent robbery circumstances and work environments. Data collection sources included police reports, employee interviews, store evaluations, and relevant Census data. Rate ratios and correlation statistics were calculated to identify associations with injury and relationships between variables. Injury risk was strongly associated with the following characteristics: employee resistance, robberies without firearms or money taken, daytime and merchandise robberies, stores with limited escape routes and no cash policy or drop safe, older clerks, and surrounding areas with lower valued buildings, less expensive rent, more vacant structures, and younger residents. Numerous intercorrelations between these characteristics were identified. Training opportunities, store procedures, and environmental designs are important factors to consider in reducing robbery-related injuries. Published 2001 Wiley-Liss, Inc

  15. Partitioned key-value store with atomic memory operations

    Energy Technology Data Exchange (ETDEWEB)

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2017-02-07

    A partitioned key-value store is provided that supports atomic memory operations. A server performs a memory operation in a partitioned key-value store by receiving a request from an application for at least one atomic memory operation, the atomic memory operation comprising a memory address identifier; and, in response to the atomic memory operation, performing one or more of (i) reading a client-side memory location identified by the memory address identifier and storing one or more key-value pairs from the client-side memory location in a local key-value store of the server; and (ii) obtaining one or more key-value pairs from the local key-value store of the server and writing the obtained one or more key-value pairs into the client-side memory location identified by the memory address identifier. The server can perform functions obtained from a client-side memory location and return a result to the client using one or more of the atomic memory operations.

  16. Decisive Visual Saliency and Consumers' In-store Decisions

    DEFF Research Database (Denmark)

    Clement, Jesper; Aastrup, Jesper; Forsberg, Signe Charlotte

    2015-01-01

    This paper focuses on consumers' in-store visual tactics and decision-making. It has been argued that many consumers shop by routine or by simple rules and justification techniques when they purchase daily commodities. It has also been argued that they make a majority of decisions in the shop......, and that they are affected by the visual stimuli in the store. The objective for this paper is to investigate the visual saliency from two factors: 1) in-store signage and 2) placement of products. This is done by a triangulation method where we utilize data from an eye-track study and sales data from grocery stores....... The first study takes place in laboratory settings with a simulated purchase situation, and the second research design builds on manipulated in-store settings and data from real purchases. We found optimal placement of two comparable goods (branded good and private label) to increase visual attention...

  17. Investigation of the quality of stored red blood cells after simulated air drop in the maritime environment.

    Science.gov (United States)

    Meli, Athinoula; Hancock, Vicky; Doughty, Heidi; Smedley, Steve; Cardigan, Rebecca; Wiltshire, Michael

    2018-02-01

    Maritime medical capability may be compromised by blood resupply. Air-dropped red blood cells (RBCs) is a possible mitigation factor. This study set out to evaluate RBC storage variables after a simulated parachute air drop into the sea, as limited data exist. The air load construction for the air drop of blood was subject to static drop assessment to simulate a worst-case parachute drop scenario. One control and two test Golden Hour shipping containers were each packaged with 10 RBC units. The control box was not dropped; Test Boxes 1 and 2 were further reinforced with waterproof boxes and underwent a simulated air drop on Day 7 or Day 8 postdonation, respectively. One day after the drop and once a week thereafter until Day 43 of storage, RBCs from each box were sampled and tested for full blood counts, hemolysis, adenosine triphosphate, 2,3-diphosphoglycerate, pH, extracellular potassium, glucose, lactate, deformability, and RBC microvesicles. The packaging configuration completed the air drop with no water ingress or physical damage. All units met UK specifications for volume, hemoglobin, and hemolysis. There were no significant differences for any of the variables studied between RBCs in the control box compared to RBCs in Test Boxes 1 and 2 combined over storage. The test proved that the packaging solution and the impact of a maritime air drop as performed in this study, on Day 7 or Day 8 postdonation, did not affect the in vitro quality of RBCs in SAGM over storage for 35 days. © 2017 AABB.

  18. Description of the digital formats of electronic documents used in digital library

    International Nuclear Information System (INIS)

    Galabova, Sevdalina; Trencheva, Tereza; Trenchev, Ivan

    2009-01-01

    A digital library is a library where collections are stored in electronic formats and are easy to be accessed by computers. The digital content may be stored by local machine, or accessed remotely via computer networks. A digital library is a type of information retrieval system. In this paper we will present a few digital format as pdf, djvu and etc. It will be denote the specific of the formats, their history and licenses policy. We will discuss different similarities between these formats.. Keywords: digital library, electronic formats, pdf, djvu

  19. A novel system for providing compatible blood to patients during surgery: "self-service" electronic blood banking by nursing staff.

    Science.gov (United States)

    Cheng, G; Chiu, D S; Chung, A S; Wong, H F; Chan, M W; Lui, Y K; Choy, F M; Chan, J C; Chan, A H; Lam, S T; Fan, T C

    1996-04-01

    A good blood bank must be able to provide compatible blood units promptly to operating room patients with minimal wastage. A "self-service" by nursing staff blood banking system that is safe, efficient, and well-accepted has been developed. Specific blood units are no longer assigned to surgical patients who have a negative pretransfusion antibody screen, irrespective of the type of surgery. A computer-generated list of the serial numbers of all group-identical blood units currently in the blood bank inventory is provided for each patient. The units themselves are not labeled with a patient's name. The group O list will be provided for group O patients, the group A list for group A patients, and so forth. Should the patient require transfusion during surgery, the operating room nurses go to the refrigerator, remove any group-identical unit, and check the serial number of the unit against the serial numbers on the patient's list. If the serial number is on that list, the blood bank will accept responsibility for compatibility. The system was implemented in 1995. Since implementation, a total of 2154 patients have undergone operations at this hospital. Thirty-two patients received more than 10 units of red cells each. There were no transfusion errors. The crossmatch-to-transfusion ratio was reduced from 1.67 to 1.12. Turnaround time for supplying additional or urgent units to patients in operating room was shortened from 33 to 2.5 minutes. There was no incidence of a blood unit's serial number not being on the list. Work by nurses and technical staff was reduced by nearly 50 percent. The "self-service" (by nursing staff) blood banking system described is safe and efficient. It saves staff time and can be easily set up.

  20. 41 CFR 109-27.5006 - Stores catalogs.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Stores catalogs. 109-27.5006 Section 109-27.5006 Public Contracts and Property Management Federal Property Management...-INVENTORY MANAGEMENT 27.50-Inventory Management Policies, Procedures, and Guidelines § 109-27.5006 Stores...

  1. Designing pharmacy services based on grocery store patron preferences.

    Science.gov (United States)

    Lindstrom, Nicolette S Raya; Casper, Kristin A; Green, Tara R; Pedersen, Craig A

    2007-01-01

    To assess preferences of grocery store patrons concerning pharmacy services and identify study participant characteristics that may predict the success of pharmacy services in the community setting. Self-administered survey. Central Ohio from December 16, 2005, to January 12, 2006. 163 grocery store patrons. Eight grocery store survey events. Responses to survey items about (1) perceived importance of 28 pharmacy services, (2) identification of the 3 most important services, (3) frequency of grocery store and pharmacy use, (4) preferred methods of advertising pharmacy services, and (5) socioeconomic demographics. Preferred services delineated by various demographics also were analyzed. A total of 163 surveys were returned from study participants. Nine services appeared in both the top 12 overall preferred services and the 12 highest-ranked services. Statistically significant differences were observed among services ranked as important or very important by age, race, employment, income, caregiver status, and prescription drug coverage status. The three advertising tools selected most frequently included: weekly grocery store ads (68.6%), in-store signs (51.0%), and flyers attached to prescription bags (36.0%). Grocery store patrons would like a wide range of nontraditional pharmacy services that could be implemented into community pharmacies. Pharmacies in grocery stores need to provide both traditional and expanded pharmacy services to meet the desires and expectations of current and potential patients, and expanded marketing methods should be considered.

  2. Explaining Online Purchase Intentions: A Multi-Channel Store Image Perspective

    OpenAIRE

    Dolen, van, Willemijn; Verhagen, Tibert

    2007-01-01

    This study is one of the few empirical works addressing the impact of offline and online store impressions on consumer online purchase intentions. Building upon the literature on store image and consumer online purchasing, we propose positive effects of online store image and suggest mixed influences of offline store image perceptions. Drawing on a sample of 630 customers of one of the largest music retail stores in the Netherlands, hypotheses are tested. The empirical results clearly support...

  3. A simple cryo-holder facilitates specimen observation under a conventional scanning electron microscope.

    Science.gov (United States)

    Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun

    2012-02-01

    A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.

  4. Toroidal electron beam energy storage for controlled fusion

    International Nuclear Information System (INIS)

    Clark, W.; Korn, P.; Mondelli, A.; Rostoker, N.

    1976-01-01

    In the presence of an external magnetic field stable equilibria exist for an unneutralized electron beam with ν/γ >1. As a result, it is in principle, possible to store very large quantities of energy in relatively small volumes by confining an unneutralized electron beam in a Tokamak-like device. The energy is stored principally in the electrostatic and self-magnetic fields associated with the beam and is available for rapid heating of pellets for controlled fusion. The large electrostatic potential well in such a device would be sufficient to contain energetic alpha particles, thereby reducing reactor wall bombardment. This approach also avoids plasma loss and wall bombardment by charge exchange neutrals. The conceptual design of an electrostatic Tokamak fusion reactor (ETFR) is discussed. A small toroidal device (the STP machine) has been constructed to test the principles involved. Preliminary experiments on this device have produced electron densities approximately 10% of those required in a reactor

  5. Spontaneous transfer of magnetically stored energy to Kinetic energy by electric double layers

    International Nuclear Information System (INIS)

    Lindberg, L.; Torven, S.

    1983-05-01

    Current disruptions are investigated in a magnetized plasma column with an inductive external electric circuit. It is found that they persist in spite of the fact that each disruption gives rise to a large inductive over-voltage. This drops off at an electric double layer formed in the plasma where most of the magnetic energy, initially stored in the circuit inductance, is released as particle energy. Simultanously as the current disrupts, the potential level at a local potential minimum in the plasma decreases. This is expected to cause the disruption by reflection of electrons. (authors)

  6. Energy stored in irradiated NaCl

    International Nuclear Information System (INIS)

    Lidiard, A.B.

    1979-01-01

    Recently reported measurements of the energy stored in heavily irradiated NaCl are reviewed in the light of recent understanding of radiation-damage processes in this material. It is shown that, in the ranges of temperatures and dose rates of these experiments, the F-centres produced by the irradiation are retained principally in the form of colloids: the stored energy is thus a direct measure of the number of F-centres retained in this form. Comparison of these results with the prediction of the recently proposed theory of colloid growth shows that the predictions of the dependence of colloid growth rates upon temperature and dose rate are qualitatively correct. The dependence of stored energy dose, however, appears to require the inclusion of a thermally activated back-reaction and possible modifications to the theory are briefly discussed. However, further experiments in this range of temperatures and dose rates are necessary for more quantitative tests of the theory. This reconsideration of the data does not alter the broad conclusion as to the relative insignificance of stored energy in a natural salt formation used as a radioactive waste repository, although more extensive measurements permitting a more exact test of theory would allow better predictions to be made for such applications. (author)

  7. [Complete blood count reference values of donated cord blood from Korean neonates].

    Science.gov (United States)

    Lee, Hye Ryun; Shin, Sue; Yoon, Jong Hyun; Kim, Byoung Jae; Hwang, Kyu Ri; Kim, Jin Ju; Roh, Eun Youn

    2009-06-01

    In the public cord blood (CB) banks, only safe CB units with adequate cell doses are processed and stored. Complete blood count (CBC) of CB is crucial for estimating total nucleated cells (TNC) and screening suitable CB units without hematologic abnormalities. We analyzed CBC parameters of the donated CB from healthy Korean neonates to establish CBC reference values. A total of 2,129 Korean CB units, donated and processed during the period from August 2007 to December 2007, were enrolled. We measured hemoglobin (Hb), white blood cell (WBC) count, differential count of WBC, platelets and nucleated red blood cell (nRBC) count by XE-2100 automated hematology analyzer (Sysmex, Japan), and estimated reference value of each parameter by using parametric (Mean+/-2SD) and/or non-parametric methods (2.5-97.5 percentile). And also, we compared the result of each parameter in relation to sex of neonates and delivery method. Because the differences of CBC values among different subgroups were not remarkable, we established the reference intervals as follows without subgroup division: Hb, 9.0-14.4 g/dL; WBC count, 5.6-18.5 x 10(3)/microL; differential count of WBC (neutrophils, 40.8-72.4%; lymphocytes, 17.2-46.7%; monocytes, 4.9-12.8%; eosinophils, 0.7-7.0%; basophils, 0.0-1.6%); platelet, 130-287 x 10(3)/microL; nRBCs, 0.0-13.1/100 WBC. We established cord blood CBC reference values of healthy Korean neonates using a large-scale CB units. The established CBC reference values from our study will be useful as basic data for CBC interpretation and assessment of transplant suitability of donated CB.

  8. Autologous Blood Transfusion in Sports: Emerging Biomarkers.

    Science.gov (United States)

    Salamin, Olivier; De Angelis, Sara; Tissot, Jean-Daniel; Saugy, Martial; Leuenberger, Nicolas

    2016-07-01

    Despite being prohibited by the World Anti-Doping Agency, blood doping through erythropoietin injection or blood transfusion is frequently used by athletes to increase oxygen delivery to muscles and enhance performance. In contrast with allogeneic blood transfusion and erythropoietic stimulants, there is presently no direct method of detection for autologous blood transfusion (ABT) doping. Blood reinfusion is currently monitored with individual follow-up of hematological variables via the athlete biological passport, which requires further improvement. Microdosage is undetectable, and suspicious profiles in athletes are often attributed to exposure to altitude, heat stress, or illness. Additional indirect biomarkers may increase the sensitivity and specificity of the longitudinal approach. The emergence of "-omics" strategies provides new opportunities to discover biomarkers for the indirect detection of ABT. With the development of direct quantitative methods, transcriptomics based on microRNA or messenger RNA expression is a promising approach. Because blood donation and blood reinfusion alter iron metabolism, quantification of proteins involved in metal metabolism, such as hepcidin, may be applied in an "ironomics" strategy to improve the detection of ABT. As red blood cell (RBC) storage triggers changes in membrane proteins, proteomic methods have the potential to identify the presence of stored RBCs in blood. Alternatively, urine matrix can be used for the quantification of the plasticizer di(2-ethyhexyl)phthalate and its metabolites that originate from blood storage bags, suggesting recent blood transfusion, and have an important degree of sensitivity and specificity. This review proposes that various indirect biomarkers should be applied in combination with mathematical approaches for longitudinal monitoring aimed at improving ABT detection. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Effect of warming and flow rate conditions of blood warmers on red blood cell integrity.

    Science.gov (United States)

    Poder, T G; Pruneau, D; Dorval, J; Thibault, L; Fisette, J-F; Bédard, S K; Jacques, A; Beauregard, P

    2016-11-01

    Fluid warmers are routinely used to reduce the risk of hypothermia and cardiac complications associated with the infusion of cold blood products. However, warming blood products could generate haemolysis. This study was undertaken to compare the impact of temperature of blood warmers on the per cent haemolysis of packed red blood cells (RBCs) heated at different flow rates as well as non-flow conditions. Infusion warmers used were calibrated at 41·5°C ± 0·5°C and 37·5°C ± 0·5°C. Cold RBC units stored at 4°C in AS-3 (n = 30), aged 30-39 days old, were divided into half units before being allocated under two different scenarios (i.e. infusion pump or syringe). Blood warmers were effective to warm cold RBCs to 37·5°C or 41·5°C when used in conjunction with an infusion pump at flow rate up to 600 ml/h. However, when the warmed blood was held in a syringe for various periods of time, such as may occur in neonatal transfusions, the final temperature was below the expected requirements with measurement as low as 33·1°C. Increasing the flow with an infusion pump increased haemolysis in RBCs from 0·2% to up to 2·1% at a flow rate of 600 ml/h regardless of the warming device used (P < 0·05). No relevant increase of haemolysis was observed using a syringe. The use of a blood warmer adjusted to 41·5°C is probably the best choice for reducing the risk of hypothermia for the patient without generating haemolysis. However, we should be cautious with the use of an infusion pump for RBC transfusion, particularly at high flow rates. © 2016 International Society of Blood Transfusion.

  10. Electronic Textbook in Human Physiology.

    Science.gov (United States)

    Broering, Naomi C.; Lilienfield, Lawrence S.

    1994-01-01

    Describes the development of an electronic textbook in human physiology at the Georgetown University Medical Center Library that was designed to enhance learning and visualization through a prototype knowledge base of core instructional materials stored in digital format on Macintosh computers. The use of computers in the medical curriculum is…

  11. Platelet-, leucocyte- and red cell-derived microparticles in stored whole blood, with and without leucofiltration, with and without ionising radiation.

    Science.gov (United States)

    Saito, Shunnichi; Nollet, Kenneth E; Ngoma, Alain M; Ono, Takako; Ohto, Hitoshi

    2018-02-01

    Storage lesion, including microparticle formation, has been partially characterised in whole blood, but not in all combinations of pre-storage leucofiltration and/or irradiation. Single-donor whole blood products were processed into four subunits: with and without leucofiltration, with and without X-irradiation (25 Gy). Platelet-, leucocyte-, and erythrocyte-derived microparticles and free haemoglobin were measured periodically throughout 42 days of storage. Pre-storage leucofiltration substantially reduced platelet- and leucocyte-derived microparticle counts throughout storage. Irradiation, in contrast, had no significant effect on microparticle counts. A gate for all microparticles showed a substantial time-dependent increase in unfiltered whole blood. A time-dependent increase in free haemoglobin was greatest in unfiltered, irradiated whole blood. This study indicates that leucofiltration can prevent the formation of leucocyte- and platelet-derived microparticles, and might reduce haemolysis in irradiated whole blood, either by removing factors that provoke haemolysis, or by selective retention of senescent or effete red cells most prone to haemolysis.

  12. Electronic health records

    DEFF Research Database (Denmark)

    Kierkegaard, Patrick

    2011-01-01

    that a centralised European health record system will become a reality even before 2020. However, the concept of a centralised supranational central server raises concern about storing electronic medical records in a central location. The privacy threat posed by a supranational network is a key concern. Cross......-border and Interoperable electronic health record systems make confidential data more easily and rapidly accessible to a wider audience and increase the risk that personal data concerning health could be accidentally exposed or easily distributed to unauthorised parties by enabling greater access to a compilation...... of the personal data concerning health, from different sources, and throughout a lifetime....

  13. Detection of newly produced T and B lymphocytes by digital PCR in blood stored dry on nylon flocked swabs.

    Science.gov (United States)

    Tessitore, Marion Vaglio; Sottini, Alessandra; Roccaro, Aldo M; Ghidini, Claudia; Bernardi, Simona; Martellosio, Giovanni; Serana, Federico; Imberti, Luisa

    2017-04-05

    A normal number of T-cell receptor excision circles (TRECs) and K-deleting recombination excision circles (KRECs) is considered a biomarker for adequate new T- and B-cell production. In newborns, detection of TRECs and KRECs by real time PCR from dried blood spotted on filter paper is used for the screening of severe immunodeficiency. In adults, elderly and during diseases, where the number of TRECs is lower than in newborns and children, a large amount of DNA and a sensitive method of amplification are necessary to identify newly produced lymphocytes. DNA was prepared from blood of 203 healthy adults (range: 18-91 years old) absorbed for 10 s on flocked swabs and let to dry, or from peripheral blood mononuclear cells. DNA was subjected to digital PCR and to well established conventional real time PCR-based method using TREC- and KREC-specific primers and probes. The number of TRECs and KRECs was expressed per mL of blood. Statistical analysis was performed by nested ANOVA, Pearson coefficient of determination, and by linear regression tests. The novel method for the storage of dried blood on nylon flocked swabs and the use of digital PCR allow quantification of TRECs and KRECs with high degree of sensitivity, specificity, accuracy, and precision. TRECs and KRECs were amplified by digital PCR in all tested blood samples, including those obtained from elderly individuals (>70 years old) and that were negative by real time PCR. Furthermore, values of TRECs and KRECs obtained by digital PCR were in the range of those acquired by real time PCR. Our findings demonstrate that DNA isolation from dried blood on flocked swabs followed by digital PCR-based analysis represents a useful tool for studying new lymphocyte production in adults and elderly individuals. This suggests the potential use of the methodology when monitoring of clinical variables is limited by the number of molecules that can be amplified and detected, such as in patients with immunodeficiency or under

  14. Inexpensive read-out for coincident electron spectroscopy with a transmission electron microscope at nanometer scale using micro channel plates and multistrip anodes

    International Nuclear Information System (INIS)

    Hollander, R.W.; Bom, V.R.; Van Eijk, C.W.E.; Faber, J.S.; Hoevers, H.; Kruit, P.

    1994-01-01

    The elemental composition of a sample at nanometer scale is determined by measurement of the characteristic energy of Auger electrons, emitted in coincidence with incoming primary electrons from a microbeam in a scanning transmission electron microscope (STEM). Single electrons are detected with position sensitive detectors, consisting of MicroChannel Plates (MCP) and MultiStrip Anodes (MSA), one for the energy of the Auger electrons (Auger-detector) and one for the energy loss of primary electrons (EELS-detector). The MSAs are sensed with LeCroy 2735DC preamplifiers. The fast readout is based on LeCroy's PCOS III system. On the detection of a coincidence (Event) energy data of Auger and EELS are combined with timing data to an Event word. Event words are stored in list mode in a VME memory module. Blocks of Event words are scanned by transputers in VME and two-dimensional energy histograms are filled using the timing information to obtain a maximal true/accidental ratio. The resulting histograms are stored on disk of a PC-386, which also controls data taking. The system is designed to handle 10 5 Events per second, 90% of which are accidental. In the histograms the ''true'' to ''accidental'' ratio will be 5. The dead time is 15%. ((orig.))

  15. NASA Armstrong's Approach to Store Separation Analysis

    Science.gov (United States)

    Acuff, Chris; Bui, Trong

    2015-01-01

    Presentation will an overview of NASA Armstrong's store separation capabilities and how they have been applied recently. Objective of the presentation is to brief Generation Orbit and other potential partners on NASA Armstrong's store separation capabilities. It will include discussions on the use of NAVSEP and Cart3D, as well as some Python scripting work to perform the analysis, and a short overview of this methodology applied to the Towed Glider Air Launch System. Collaboration with potential customers in this area could lead to funding for the further development of a store separation capability at NASA Armstrong, which would boost the portfolio of engineering expertise at the center.

  16. Deploying Electronic Roadside Vehicle Identification Technology to ...

    African Journals Online (AJOL)

    ... suicide bombing, ritual murders and human parts selling. ..... Table 1.1: Prototype Platforms For VANET And WSN Nodes [11] ... store items are common examples. This is the one .... viewed on electronic maps via the internet or specialized ...

  17. The impact of storage time of transfused blood on postoperative infectious complications in rectal cancer surgery. Danish RANX05 Colorectal Cancer Study Group

    DEFF Research Database (Denmark)

    Mynster, T; Nielsen, Hans Jørgen

    2000-01-01

    BACKGROUND: We have studied the impact of storage time of transfused allogeneic blood together with other known risk factors on postoperative infectious complications after operation for rectal cancer. METHODS: Intra-abdominal abscess, anastomotic leakage, septicaemia, wound infection, and pneumo......BACKGROUND: We have studied the impact of storage time of transfused allogeneic blood together with other known risk factors on postoperative infectious complications after operation for rectal cancer. METHODS: Intra-abdominal abscess, anastomotic leakage, septicaemia, wound infection...... and storage time of saline-adenine-glucose-mannitol (SAGM) blood, administered to each patient, were recorded retrospectively. RESULTS: The overall infection rate was 24% in 78 non-transfused and 40% in 225 transfused patients (P = 0.011). The proportion of SAGM blood stored for > or = 21 days administered...... to each transfused patient was a median of 60% in patients developing postoperative infections versus 25% (P = 0.037) in patients without infections. A multivariate analysis of significant risk variables showed weight > 75 kg (odds ratio, 2.0 versus blood stored > or = 21...

  18. High Performance Experiment Data Archiving with gStore

    Energy Technology Data Exchange (ETDEWEB)

    Goeringer, H; Feyerabend, M; Sedykh, S [GSI Helmholtzzentrum fuer Schwerionenforschung - Center for Heavy Ion Research Planckstr. 1, D-64291 Darmstadt (Germany)

    2012-12-13

    GSI in Darmstadt (Germany) is a center for heavy ion research. It hosts an Alice Tier2 center and is the home of the future FAIR facility. The planned data rates of the largest FAIR experiments, CBM and Panda, will be similar to those of the current LHC experiments at Cern. gStore is a hierarchical storage system with unique name space and successfully in operation since more than fifteen years. Its core consists of several tape libraries and currently {approx}20 data mover nodes connected within a SAN network. The gStore clients transfer data via fast socket connections from/to the disk cache of the data movers ({approx}200 TByte currently). Each data mover has also a high speed connection to the GSI lustre file system ({approx}3 PByte data capacity currently). The overall bandwidth between gStore (disk cache or tape) and lustre amounts to 5 GByte/s and will be duplicated in 2012. In the near future the lustre HSM functionality will be implemented with gStore. Each tape drive is accessible from any data mover, fully transparent to the users. The tapes and libraries are managed by commercial software (IBM Tivoli Storage Manager TSM), whereas the disk cache management and the TSM and user interfaces are provided by GSI software. This provides the flexibility needed to tailor gStore according to the always developing requirements of the GSI and FAIR user communities. For Alice users all gStore data are worldwide accessible via Alice grid software. Data streams from running experiments at GSI (up to 500 MByte/s) are written via sockets from the event builders to gStore write cache for migration to tape. In parallel the data are also copied to lustre for online evaluation and monitoring. As all features related to tapes and libraries are handled by TSM gStore is practically completely hardware independent. Additionally, according to the design principles gStore is fully scalable in data capacity and I/O bandwidth. Therefore we are optimistic to fulfill also the

  19. High Performance Experiment Data Archiving with gStore

    International Nuclear Information System (INIS)

    Goeringer, H; Feyerabend, M; Sedykh, S

    2012-01-01

    GSI in Darmstadt (Germany) is a center for heavy ion research. It hosts an Alice Tier2 center and is the home of the future FAIR facility. The planned data rates of the largest FAIR experiments, CBM and Panda, will be similar to those of the current LHC experiments at Cern. gStore is a hierarchical storage system with unique name space and successfully in operation since more than fifteen years. Its core consists of several tape libraries and currently ∼20 data mover nodes connected within a SAN network. The gStore clients transfer data via fast socket connections from/to the disk cache of the data movers (∼200 TByte currently). Each data mover has also a high speed connection to the GSI lustre file system (∼3 PByte data capacity currently). The overall bandwidth between gStore (disk cache or tape) and lustre amounts to 5 GByte/s and will be duplicated in 2012. In the near future the lustre HSM functionality will be implemented with gStore. Each tape drive is accessible from any data mover, fully transparent to the users. The tapes and libraries are managed by commercial software (IBM Tivoli Storage Manager TSM), whereas the disk cache management and the TSM and user interfaces are provided by GSI software. This provides the flexibility needed to tailor gStore according to the always developing requirements of the GSI and FAIR user communities. For Alice users all gStore data are worldwide accessible via Alice grid software. Data streams from running experiments at GSI (up to 500 MByte/s) are written via sockets from the event builders to gStore write cache for migration to tape. In parallel the data are also copied to lustre for online evaluation and monitoring. As all features related to tapes and libraries are handled by TSM gStore is practically completely hardware independent. Additionally, according to the design principles gStore is fully scalable in data capacity and I/O bandwidth. Therefore we are optimistic to fulfill also the dramatically increased

  20. [Organization and technology in the grocery store sector].

    Science.gov (United States)

    Gambetti, Edy

    2014-01-01

    In Italy, grocery stores develop an annual turnover of 92 billion of , (data referred to 2013) and have 28.232 stores spread over a commercial area of 17.224.000 m2. The business involved are 252, linked with 30 important distribution leader companies. The total workforce is about 280.000 people. The grocery stores structure is composed by suppliers and producers warehouses and different kinds of stores (hypermarkets, supermarkets, shops and discounts). In the stores, the technological progress concerns fundamentally back-office operations; the improvement of information and computer science is the main renewal source. Other tasks as receiving goods and stocking shelves are still executed without specific inovations. In terms of organization, we observed a strong increase of part-time workers, the development of atypical contract and thie inclination to contract the easiest jobs (for example, stocking shelves). Also the warehouses often use to sub-contract the picking tasks. The increase of on-line shopping, also concerning the groceries, represents the most relevant evolution in tire near future.

  1. Around the Corner to Better Health: A Milwaukee Corner Store Initiative.

    Science.gov (United States)

    Young, Staci; DeNomie, Melissa; Sabir, JoAnne; Gass, Eric; Tobin, Jessie

    2017-01-01

    To discuss successes and challenges of a collaborative pilot project to increase healthy food availability in corner stores in Milwaukee, Wisconsin. The Lindsay Heights Healthy Corner Store Initiative aimed to help corner stores sell high-quality produce by increasing supply of healthy foods and funding minor store upgrades to facilitate change. Evaluation research. Milwaukee, Wisconsin. Corner stores; youth and adult community members. (1) Supporting businesses in purchasing equipment to stock fresh produce, (2) connecting stores with produce sources, and (3) community outreach and marketing. Partnership capacity, youth engagement in food justice, and community members' usage of corner stores. Qualitative analysis; descriptive statistics. Storeowners reported more sold produce items per week and increased noticeable fresh produce upon entrance into the store. There was increased or improved store redesign, fresh produce signage, in-store cooking demonstrations, and small business development resources. Youth learned about new vegetables, increased kitchen skills and proper food storage, and the effects of obesity on overall health. Similar interventions must address infrastructure costs, cooperation with property owners, and local policies and regulations affecting business practices.

  2. Threshold voltage variation depending on single grain boundary and stored charges in an adjacent cell for vertical silicon–oxide–nitride–oxide–silicon NAND flash memory

    Science.gov (United States)

    Oh, Hyeongwan; Kim, Jiwon; Baek, Rock-Hyun; Lee, Jeong-Soo

    2018-04-01

    The effects of single grain boundary (SGB) position and stored electron charges in an adjacent cell in silicon–oxide–nitride–oxide–silicon (SONOS) structures on the variations of threshold voltage (V th) were investigated using technology computer-aided design (TCAD) simulation. As the bit line voltage increases, the SGB position causing the maximum V th variation was shifted from the center to the source side in the channel, owing to the drain-induced grain barrier lowering effect. When the SGB is located in the spacer region, the potential interaction from both the SGB and the stored electron charges in the adjacent cell becomes significant and thus resulting in larger V th variation. In contrast, when the SGB is located at the center of the channel, the peak position of potential barrier is shifted to the center, so that the influence of the adjacent cell is diminished. As the gate length is scaled down to 20 nm, the influence of stored charges in adjacent cells becomes significant, resulting in larger V th variations.

  3. Transfusion of 35-day-stored red blood cells does not alter lipopolysaccharide tolerance during human endotoxemia

    NARCIS (Netherlands)

    Peters, Anna L.; van Hezel, Maike E.; Klanderman, Robert B.; Tuip-de Boer, Anita M.; Wiersinga, W. Joost; van der Spek, Anne H.; van Bruggen, Robin; de Korte, Dirk; Juffermans, Nicole P.; Vlaar, Alexander P. J.

    2017-01-01

    Transfusion-related immunomodulation (TRIM) encompasses immunosuppressive and proinflammatory effects induced by red blood cell (RBC) transfusion. Changes that occur during storage in the RBC product have been hypothesized to underlie TRIM, mediated by tolerance of toll-like receptors (TLR). We

  4. An experiment to examine the mechanistic behaviour of irradiated CANDU fuel stored under dry conditions

    International Nuclear Information System (INIS)

    Oldaker, I.E.; Crosthwaite, J.L.; Keltie, R.J.; Truss, K.J.

    1979-01-01

    A program has begun to use the Whiteshell Nuclear Research Establishment dry-storage canisters to store some selected CANDU irradiated fuel bundles in an 'easily retrievable basket.' The object of the experimental program is to study the long-term stability of the Zircaloy-sheathed UO 2 and UC fuel elements when stored in air. Bundles were loaded into a canister in October 1979 following detailed examination and removal of up to three complete elements from most bundles. These elements are currently being subjected to detailed destructive examinations, including metallography and scanning electron micrography, to fully characterize their pre-storage condition. After four years, and every five years thereafter, further elements will be examined similarly to study the effects of the storage environment on the stability of the Zircaloy sheathing, and on its continued ability to contain the fuel safely in an interim storage facility. (author)

  5. Torness delay is storing up trouble

    International Nuclear Information System (INIS)

    Cavenagh, Andrew.

    1994-01-01

    A recent decision by the Scottish Office to delay planning permission for the construction of a 50 million dry store for spent nuclear fuel at Torness Power Station is proving frustrating and inexplicable to many in the nuclear industry. The possible reasons for this apparent about face in government policy on spent fuel management are debated and the economic ramifications of the decision for British Nuclear Fuels Limited (BNFL), if the store were to go ahead, are outlined. (UK)

  6. Method of storing fissile mateiral

    International Nuclear Information System (INIS)

    Onoshita, Toshio; Ishitobi, Masuhiro

    1989-01-01

    Upon storing nuclear fissile materials in a storing building, vessels packed with fissile materials are inserted into a containing chamber divided with partition walls comprising neutron absorbers and neutron moderators. Thus, released neutrons permeating the vessel are moderated by the neutron moderators and then absorbed by the neutron absorbers. Accordingly, the neutron absorbing effect by the neutron absorbers is improved, and irradiation of neutrons released from one of vessels to the other of vessels can be suppressed. Accordingly, it is possible to shorten the distance between the vessels in a contained state as much as possible, while securing the critical safety, to improve the containing density during storage. (T.M.)

  7. Academic Freedom and Electronic Communications

    Science.gov (United States)

    Academe, 2005

    2005-01-01

    The advent of electronic and digital communication as an integral part of academic discourse has profoundly changed the ways in which universities and their faculties pursue teaching and scholarship. Such changes are manifest in the methods by which information is obtained and disseminated, the means of storing and retrieving such information, and…

  8. Nanodefects of membranes cause destruction of packed red blood cells during long-term storage

    International Nuclear Information System (INIS)

    Kozlova, Elena; Chernysh, Aleksandr; Moroz, Victor; Sergunova, Victoria; Gudkova, Olga; Kuzovlev, Artem

    2015-01-01

    Packed red blood cells (PRBC) are used for blood transfusion. PRBC were stored for 30 days under 4 °C in hermetic blood bags with CPD anticoagulant-preservative solution. Hematocrit was 50–55%. The distortions of PRBC membranes nanostructure and cells morphology during storage were studied by atomic force microscopy. Basic measurements were performed at the day 2, 6, 9, 16, 23 and 30 of storage and additionally 2–3 days after it. Topological defects occurred on RBC membranes by day 9. They appeared as domains with grain-like structures (“grains”) sized up to 200 nm. These domains were appeared in almost all cells. Later these domains merged and formed large defects on cells. It was the formation of domains with the “grains” which was onset process leading eventually to destruction of PRBC. Possible mechanisms of transformation of PRBC and their membrane are related to the alterations of spectrin cytoskeleton. During this storage period potassium ions and lactat concentrations increased, pH decreased, intracellular concentration of reduced glutathione diminished in the preservative solution. Changes of PRBC morphology were detected within the entire period of PRBC storage. Discocytes predominated at the days 1 and 2. By day 30 PRBC transformed into irreversible echinocytes and spheroechinocytes. Study of defects of membranes nanostructure may form the basis of assessing the quality of the stored PRBC. This method may allow to work out the best recommendations for blood transfusion. - Highlights: • Domains with “grains” are formed on membranes surface on 9–16 days of PRBC storage. • The development of domains is the reason of irreversible changes of PRBC structure. • The origin of domains is the consequence of alterations of spectrin cytoskeleton. • Study of nanostructure may form basis of assessing the quality of the stored PRBC

  9. Nanodefects of membranes cause destruction of packed red blood cells during long-term storage

    Energy Technology Data Exchange (ETDEWEB)

    Kozlova, Elena, E-mail: waterlake@mail.ru [V.A. Negovsky Scientific Research Institute of General Reanimatology, Moscow (Russian Federation); I.M. Sechenov First Moscow State Medical University, Moscow (Russian Federation); Chernysh, Aleksandr [V.A. Negovsky Scientific Research Institute of General Reanimatology, Moscow (Russian Federation); I.M. Sechenov First Moscow State Medical University, Moscow (Russian Federation); Moroz, Victor; Sergunova, Victoria; Gudkova, Olga; Kuzovlev, Artem [V.A. Negovsky Scientific Research Institute of General Reanimatology, Moscow (Russian Federation)

    2015-10-01

    Packed red blood cells (PRBC) are used for blood transfusion. PRBC were stored for 30 days under 4 °C in hermetic blood bags with CPD anticoagulant-preservative solution. Hematocrit was 50–55%. The distortions of PRBC membranes nanostructure and cells morphology during storage were studied by atomic force microscopy. Basic measurements were performed at the day 2, 6, 9, 16, 23 and 30 of storage and additionally 2–3 days after it. Topological defects occurred on RBC membranes by day 9. They appeared as domains with grain-like structures (“grains”) sized up to 200 nm. These domains were appeared in almost all cells. Later these domains merged and formed large defects on cells. It was the formation of domains with the “grains” which was onset process leading eventually to destruction of PRBC. Possible mechanisms of transformation of PRBC and their membrane are related to the alterations of spectrin cytoskeleton. During this storage period potassium ions and lactat concentrations increased, pH decreased, intracellular concentration of reduced glutathione diminished in the preservative solution. Changes of PRBC morphology were detected within the entire period of PRBC storage. Discocytes predominated at the days 1 and 2. By day 30 PRBC transformed into irreversible echinocytes and spheroechinocytes. Study of defects of membranes nanostructure may form the basis of assessing the quality of the stored PRBC. This method may allow to work out the best recommendations for blood transfusion. - Highlights: • Domains with “grains” are formed on membranes surface on 9–16 days of PRBC storage. • The development of domains is the reason of irreversible changes of PRBC structure. • The origin of domains is the consequence of alterations of spectrin cytoskeleton. • Study of nanostructure may form basis of assessing the quality of the stored PRBC.

  10. The effect of repeated blood donations on the iron status of male Saudi blood donors

    Science.gov (United States)

    Abdullah, Saleh M.

    2011-01-01

    Background. Regular blood donation can lead to iron deficiency. Screening donors’ serum ferritin levels at the time of first donation and subsequently once every year is a very rational way to pick up iron deficiency in a voluntary blood donor population. The aim of this study was to determine the effect of blood donation and the prevalence of erythropoiesis with iron deficiency (sideropenia) in Saudi male blood donors. Materials and methods. The study was prospectively conducted, between December 2008 and March 2009, on 182 male native Saudi blood donors at King Fahd Central Hospital in Jazan region, Saudi Arabia. Each donor gave 450±50 mL of whole blood. Following the donation, samples were removed into 2.5 mL EDTA tubes for measurement of mean cell volume (MCV) and mean corpuscular haemoglobin (MCH) and into 7.5 mL plain tubes for estimation of iron and serum ferritin concentrations. The blood donors were divided into five groups, according to the number of donations they had given in the preceding 3 years. The blood donors in group I were first-time donors, with no previous history of blood donation. Group II donors had donated once in the last 3 years. Subjects in groups III, IV and V had donated more than once in the preceding 3 years and were considered regular donors. Results. The mean serum iron was significantly higher among subjects with no previous history of blood donation (group I) than among regular donors who had donated twice or more. The difference in serum ferritin concentration was statistically significant (pdonated once in the last 3 years, and in first-time blood donors (131.4 μg/L) was not statistically significant (pdonated between two to five times had iron deficiency. The prevalence of erythropoiesis with iron deficiency in regular blood donors was 4.3%. Conclusion. The results of this study show that an increase in the number of donations results in an increase in the frequency of depleted iron stores and subsequently in

  11. Blood transport method for chromosome analysis of residents living near Semipalatinsk nuclear test site.

    Science.gov (United States)

    Rodzi, Mohd; Ihda, Shozo; Yokozeki, Masako; Takeichi, Nobuo; Tanaka, Kimio; Hoshi, Masaharu

    2009-12-01

    A study was conducted to compare the storage conditions and transportation period for blood samples collected from residents living in areas near the Semipalatinsk nuclear test site (SNTS). Experiments were performed to simulate storage and shipping environments. Phytohaemagglutinin (PHA)-stimulated blood was stored in 15-ml tubes (condition A: current transport method) in the absence or in 50-ml flasks (condition B: previous transport method) in the presence of RPMI-1640 and 20% fetal bovine serum (FBS). Samples were kept refrigerated at 4 degrees C and cell viability was assessed after 3, 8, 12 and 14 days of storage. RPMI-1640, 20% FBS and further PHA were added to blood samples under condition A in 50-ml flasks for culture. Whole-blood samples under condition B were directly incubated without further sub-culturing process, neither media nor PHA were added, to adopt a similar protocol to that employed in the previous transport method. Samples in condition A and condition B were incubated for 48 hr at 37 degrees C and their mitotic index was determined. The results showed that viable lymphocytes were consistent in both storage conditions but the mitotic index was higher in condition A than in condition B. Although further confirmation studies have to be carried out, previous chromosomal studies and the present experiment have shown that PHA-stimulated blood could be stored without culture medium for up to 8 days under condition A. The present results will be useful for cytogenetic analysis of blood samples that have been transported long distances wherever a radiation accident has occurred.

  12. Shaktismen - hinduismens store gudindetradition

    DEFF Research Database (Denmark)

    Olesen, Bjarne Wernicke

    2008-01-01

    Artiklen giver en introduktion til shaktismen - hinduismens store gudindetradition. Den ser på de vigtigste gudinder, begreber, traditioner og forestillinger, ligesom den giver et vue over forskningssituationen. Shaktismens opståen i sin klassiske form, dens hovedretninger, virkelighedsforståelse...

  13. Erythrocyte endogenous proteinase activity during blood bank storage.

    Science.gov (United States)

    de Angelis, V; de Matteis, M C; Orazi, B M; Santarossa, L; Della Toffola, L; Raineri, A; Vettore, L

    1990-01-01

    We studied proteolytic alterations of membrane proteins in ghosts derived from human red blood cells, preserved up to 35 days in the liquid state either as whole blood or with additive solution. The study was carried out by performing sodium dodecyl sulfate polyacrylamide gel electrophoresis of stromal proteins from erythrocytes, either previously treated with proteinase inhibitors or previously incubated in conditions promoting proteolysis. To differentiate the effect of erythrocyte from granulocyte proteinases, the investigation was also carried out in leukocyte-free red cell preparations. The results show: (1) the effects of endogenous proteinases on membrane proteins derived from red cells stored under blood bank conditions; (2) a decrease of proteolytic effects in ghosts derived from red cells which have been submitted to a longer storage; (3) a relevant influence of the red cell resuspending medium before lysis on the time-dependent onset and exhaustion of proteolysis in ghosts. The presence of increased proteolysis in ghosts could be regarded as a marker of molecular lesions induced in red cells by storage under blood bank conditions.

  14. In-Store Experimental Approach to Pricing and Consumer Behavior

    Science.gov (United States)

    Sigurdsson, Valdimar; Foxall, Gordon; Saevarsson, Hugi

    2010-01-01

    This study assessed how, and to what extent, it is possible to use behavioral experimentation and relative sales analysis to study the effects of price on consumers' brand choices in the store environment. An in-store experiment was performed in four stores to investigate the effects of different prices of a target brand on consumers' relative…

  15. Dry fuel store for advanced gas cooled reactor fuels

    International Nuclear Information System (INIS)

    Grant, J.S.; Boocock, P.M.; Ealing, C.J.

    1992-01-01

    This paper summarizes the fuel storage requirements in Scotland and the selection of a Dry Fuel Store of the Modular Vault Dry Store (MVDS) design developed by GEC ALSTHOM Engineering Systems Limited (GECA). A similar design of store has been selected and has been constructed in the USA by Foster Wheeler Energy Corporation in collaboration with GECA

  16. DEVELOPMENT OF A METHOD FOR QUANTITATING SPHINGOID BASE 1-PHOSPHATES IN BLOOD SPOTS

    Science.gov (United States)

    Red blood cells (RBC) accumulate, store and release sphingoid base 1-phosphates,important ligands for the extracellular receptors S1P1-5. The ability of RBC to accumulate these bioactive lipids is because, with the exception of sphingosine kinase, the enzymes responsible for metabolizing sphingosine...

  17. An astrophysical engine that stores gravitational work as nuclear Coulomb energy

    Science.gov (United States)

    Clayton, Donald

    2014-03-01

    I describe supernovae gravity machines that store large internal nuclear Coulomb energy, 0.80Z2A- 1 / 3MeV per nucleus. Excess of it is returned later by electron capture and positron emission. Decay energy manifests as (1) observable gamma-ray lines (2) light curves of supernovae (3) chemical energy of free carbon dissociated from CO molecules (4) huge abundances of radiogenic daughters. I illustrate by rapid silicon burning, a natural epoch in SN II. Gravitational work produces the high temperatures that photoeject nucleons and alpha particles from heavy nuclei. These are retained by other nuclei to balance photoejection rates (quasiequilibrium). The abundance distribution adjusts slowly as remaining abundance of Z = N 28Si decomposes, so p, n, α recaptures hug the Z = N line. This occurs in milliseconds, too rapidly for weak decay to alter bulk Z/N ratio. The figure displays those quasiequilibrium abundances color-coded to their decays. Z = N = 2k nuclei having k 10 are radioactive owing to excess Coulomb energy. Weak decays radiate that excess energy weeks later to fuel the four macroscopic energetic phenomena cited. How startling to think of the Coulomb nuclear force as storing cosmic energy and its weak decay releasing macroscopic activation to SNII.

  18. An Electronic open-quotes Barn Bookclose quotes

    International Nuclear Information System (INIS)

    James, J.Z.

    1996-01-01

    Electronic publication of a comprehensive compilation of neutron cross sections - an open-quotes electronic barn bookclose quotes - can be of immense value to the practicing nuclear engineer, as well as in nuclear education and training. This paper describes such a publication. The files are published on compact disk-read-only memory (CD-ROM), with automatic updating over the Internet. The current version stores the curves graphically, but a future version will take better advantage of the interactive capabilities of electronic publishing by drawing the curves from ACE files open-quotes on the fly.close quotes

  19. 76 FR 48167 - Agency Information Collection Activities; Proposed Collection; Comment Request; Blood...

    Science.gov (United States)

    2011-08-08

    ... requirements in the Agency's regulations and Form FDA 2830. DATES: Submit either electronic or written comments on the collection of information by October 7, 2011. ADDRESSES: Submit electronic comments on the... plasma donor centers, blood banks, certain transfusion services, other blood product manufacturers, and...

  20. High-Quality and -Quantity DNA Extraction from Frozen Archival Blood Clots for Genotyping of Single-Nucleotide Polymorphisms

    DEFF Research Database (Denmark)

    Bank, Steffen; Nexø, Bjørn Andersen; Andersen, Vibeke

    2013-01-01

    the efficiency of commercial purification kits for extracting DNA from long-term frozen clotted blood. Methods: Serum tubes with clotted blood were stored at −20°C for 1 to 2.5 years before DNA extraction. DNA was extracted from 10 blood clot samples using PureGene (Qiagen) with and without glycogen, the QIAamp...... with a median of 0.65 μg (range 0.5–2.6 μg) pr 300 μL total blood. Conclusion: The yield obtained by the different commercial kits varied considerably. Our work demonstrates that high-quality and -quantity DNA can be extracted with the Maxwell 16 Blood purification kit (Promega) from cryopreserved blood clots...

  1. Comparison of some storage and isolation methods to recover bluetongue virus from bovine blood.

    OpenAIRE

    Thomas, F C

    1984-01-01

    Bovine blood containing bluetongue virus was stored as whole blood with EDTA (4 degrees C), as washed cellular components (4 degrees C), and as washed cellular components with 10% DMSO (-70 degrees C). Periodic isolation attempts were made over a period of 330 days in four cell lines and embryonating chicken eggs (intravenous inoculation). Bluetongue virus was successfully isolated in all systems from most samples throughout the test period. There appeared to be more variation amongst days of...

  2. Comparing Relational and Ontological Triple Stores in Healthcare Domain

    Directory of Open Access Journals (Sweden)

    Ozgu Can

    2017-01-01

    Full Text Available Today’s technological improvements have made ubiquitous healthcare systems that converge into smart healthcare applications in order to solve patients’ problems, to communicate effectively with patients, and to improve healthcare service quality. The first step of building a smart healthcare information system is representing the healthcare data as connected, reachable, and sharable. In order to achieve this representation, ontologies are used to describe the healthcare data. Combining ontological healthcare data with the used and obtained data can be maintained by storing the entire health domain data inside big data stores that support both relational and graph-based ontological data. There are several big data stores and different types of big data sets in the healthcare domain. The goal of this paper is to determine the most applicable ontology data store for storing the big healthcare data. For this purpose, AllegroGraph and Oracle 12c data stores are compared based on their infrastructural capacity, loading time, and query response times. Hence, healthcare ontologies (GENE Ontology, Gene Expression Ontology (GEXO, Regulation of Transcription Ontology (RETO, Regulation of Gene Expression Ontology (REXO are used to measure the ontology loading time. Thereafter, various queries are constructed and executed for GENE ontology in order to measure the capacity and query response times for the performance comparison between AllegroGraph and Oracle 12c triple stores.

  3. Role of transfused red blood cells for shock and coagulopathy within remote damage control resuscitation.

    Science.gov (United States)

    Spinella, Philip C; Doctor, Allan

    2014-05-01

    The philosophy of damage control resuscitation (DCR) and remote damage control resuscitation (RDCR) can be summarized by stating that the goal is to prevent death from hemorrhagic shock by "staying out of trouble instead of getting out of trouble." In other words, it is preferred to arrest the progression of shock, rather than also having to reverse this condition after significant tissue damage and organ injury cascades are established. Moreover, to prevent death from exsanguination, a balanced approach to the treatment of both shock and coagulopathy is required. This was military doctrine during World War II, but seemed to be forgotten during the last half of the 20th century. Damage control resuscitation and RDCR have revitalized the approach, but there is still more to learn about the most effective and safe resuscitative strategies to simultaneously treat shock and hemorrhage. Current data suggest that our preconceived notions regarding the efficacy of standard issue red blood cells (RBCs) during the hours after transfusion may be false. Standard issue RBCs may not increase oxygen delivery and may in fact decrease it by disturbing control of regional blood flow distribution (impaired nitric oxide processing) and failing to release oxygen, even when perfusing hypoxic tissue (abnormal oxygen affinity). Standard issue RBCs may assist with hemostasis but appear to have competing effects on thrombin generation and platelet function. If standard issue or RBCs of increased storage age are not optimal, then are there alternatives that will allow for an efficacious and safe treatment of shock while also supporting hemostasis? Studies are required to determine if fresh RBCs less than 7 to 10 days provide an outcome advantage. A resurgence in the study of whole blood stored at 4°C for up to 10 days also holds promise. Two randomized controlled trials in humans have indicated that following transfusion with either whole blood stored at 4°C or platelets stored at 4

  4. Blood Glucose Monitoring Before and After Type 1 Diabetes Clinic Visits.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Wright, Nancy; Deeb, Larry C

    2017-12-23

    To determine patterns of blood glucose monitoring in children and adolescents with type 1 diabetes (T1D) before and after routine T1D clinic visits. Blood glucose monitoring data were downloaded at four consecutive routine clinic visits from children and adolescents aged 5-18 years. Linear mixed models were used to analyze patterns of blood glucose monitoring in patients who had at least 28 days of data stored in their blood glucose monitors. In general, the frequency of blood glucose monitoring decreased across visits, and younger children engaged in more frequent blood glucose monitoring. Blood glucose monitoring increased before the T1D clinic visits in younger children, but not in adolescents. It declined after the visit regardless of age. Members of the T1D care team need to consider that a T1D clinic visit may prompt an increase in blood glucose monitoring when making treatment changes and recommendations. Tailored interventions are needed to maintain that higher level of adherence across time. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  5. An investigation of radiosensitivity of selected stored seed and seed borne fungi

    International Nuclear Information System (INIS)

    Maity, Jyoti Prakash; Chatterjee, S.; Mishra, D.; Chakraborty, A.; Saha, A.; Santra, S.C.; Chanda, S.

    2004-01-01

    Spoilage of nutritional value of the grains by the microbes, especially those producing mycotoxins, is a worldwide economic problem. The decontamination method, using gamma ray or fast electrons, is receiving growing attention. The present investigation was designed to determine an appropriate dose-range of gamma radiation for the stored grains to reduce levels of pathogenic fungi with minimal loss in viability, food value and/or germinating potential of the selected seeds. Further the study also aimed at assessing response of specific fungus to gamma irradiation in isolated condition and when attached to seeds to discern host-specific interaction if any, of the concerned fungi

  6. Systems and methods of storing combustion waste products

    Science.gov (United States)

    Chen, Shen-En; Wang, Peng; Miao, Xiexing; Feng, Qiyan; Zhu, Qianlin

    2016-04-12

    In one aspect, methods of storing one or more combustion waste products are described herein. Combustion waste products stored by a method described herein can include solid combustion waste products such as coal ash and/or gaseous combustion products such as carbon dioxide. In some embodiments, a method of storing carbon dioxide comprises providing a carbon dioxide storage medium comprising porous concrete having a macroporous and microporous pore structure and flowing carbon dioxide captured from a combustion flue gas source into the pore structure of the porous concrete.

  7. Measurement of the viability of stored red cells by the single-isotope technique using 51Cr. Analysis of validity

    International Nuclear Information System (INIS)

    Beutler, E.; West, C.

    1984-01-01

    A single-isotope 51 Cr method often is used to evaluate the viability of stored red cells. In this technique, the red cell mass is measured by back-extrapolation to time zero (t0) of the radioactivity of the blood between 5 and 20 minutes after infusion of the sample. If there is early destruction of stored cells, this method provides an overestimate of the red cell mass and, hence, of the viability of the stored cells. Freshly drawn red cells from normal donors were labeled with /sup 99m/Tc, and cells from the same donor which had been stored in citrate-phosphate-dextrose-adenine-one (CPDA-1) for periods ranging from 7 to 49 days were labeled with 51 Cr. A comparison of the ''true red cell mass'' as determined with /sup 99m/Tc with the back-extrapolated red cell mass from stored 51 Cr-labeled cells has made it possible to define the magnitude of error introduced by early loss of red cells. The overestimation of red cell mass and viability was diminished if only the 51 Cr radioactivity between 5 and 15 minutes after infusion was used in back-extrapolating to t0. The degree of overestimation of red cell mass was greatest when the red cell viability had declined to very low levels. However, in the entire range of 10 to 80 percent viability, the overestimate of viability was usually less than 4 percent. The overestimate of viability proved to be quite similar for all samples and may be taken into account when using the single-isotope technique for measurement of red cell viability

  8. Prevalence and determinants of declining versus stable hemoglobin levels in whole blood donors

    NARCIS (Netherlands)

    Nasserinejad, K.; van Rosmalen, J.; van den Hurk, K.; Baart, M.; Hoekstra, T.; Rizopoulos, D.; Lesaffre, E.; Kort, W.

    2015-01-01

    Background A too short recovery time after blood donation Results in a gradual depletion of iron stores and a subsequent decline in hemoglobin (Hb) levels over time. This decline in Hb levels may depend on individual, unobserved characteristics of the donor. Study Design and Methods We used a data

  9. Strategies to reduce blood product utilization in obstetric practice.

    Science.gov (United States)

    Neb, Holger; Zacharowski, Kai; Meybohm, Patrick

    2017-06-01

    Patient blood management (PBM) aims to improve patient outcome and safety by reducing the number of unnecessary RBC transfusions and vitalizing patient-specific anemia reserves. Although PBM is increasingly recognized as best clinical practice in elective surgery, implementation of PBM is restrained in the setting of obstetrics. This review summarizes recent findings to reduce blood product utilization in obstetric practice. PBM-related evidence-based benefits should be urgently adopted in the field of obstetric medicine. Intravenous iron can be considered a safe, effective strategy to replenish iron stores and to correct both pregnancy-related and hemorrhage-related iron deficiency anemia. In addition to surgical techniques and the use of uterotonics, recent findings support early administration of tranexamic acid, fibrinogen and a coagulation factor concentrate-based, viscoelastically guided practice in case of peripartum hemorrhage to manage coagulopathy. In patients with cesarean section, autologous red cell blood salvage may reduce blood product utilization, although its use in this setting is controversial. Implementation of PBM in obstetric practice offers large potential to reduce blood loss and transfusion requirements of allogeneic blood products, even though large clinical trials are lacking in this specific field. Intravenous iron supplementation may be suggested to increase peripartum hemoglobin levels. Additionally, tranexamic acid and point-of-care-guided supplementation of coagulation factors are potent methods to reduce unnecessary blood loss and blood transfusions in obstetrics.

  10. A review on plasmonic metal–TiO{sub 2} composite for generation, trapping, storing and dynamic vectorial transfer of photogenerated electrons across the Schottky junction in a photocatalytic system

    Energy Technology Data Exchange (ETDEWEB)

    Gomathi Devi, L., E-mail: gomatidevi_naik@yahoo.co.in; Kavitha, R.

    2016-01-01

    Graphical abstract: A review on noble metal deposited titania heterostructure for energy and environmental application: an exploration on site specific interaction, electrostatic effects, surface adsorption, metallic nature, size of the deposits and oxidation state of the metal. - Highlights: • Fundamental and critical issues of metal deposited TiO{sub 2} is reviewed. • Comprehensive update of design, fabrication and activity of M/TiO{sub 2} is highlighted. • Interfacial charge carrier dynamics and SPR effect of M/TiO{sub 2} is discussed. • The photophysical and photochemical properties of Pt, Au, Ag, Pd/TiO{sub 2} is analyzed. • The electrons are captured, stored and discharged through the Schottky barrier. - Abstract: The titania based nanomaterials are an attractive candidates for energy and environmental applications. TiO{sub 2} is one of the most important photocatalyst for its special multiple characteristics like high reactivity, low toxicity, low cost, high flexibility, long term stability especially in aqueous medium, shows relatively high energy conversion efficiency, easy to prepare several modifications with various morphologies, with good recycle ability, favorable band edge positions and superior physicochemical and optoelectronic properties. However, large band gap of titania and massive charge carrier recombination impairs its wide photocatalytic applications. As an alternative to various strategies reported extensively in literature, noble metal deposition on the titania surface seems to be effective and reliable method for increasing the life time of excitonic pairs and to extend the band gap absorption to visible range of the solar spectrum. In this focused review, we discuss the fundamental and critical issues in the photocatalytic activity of metal deposited titania taking into consideration the influence of various parameters like preparation methods, metal dispersion on titania, formation of heterojunctions and optimum metal

  11. ACOG committee opinion number 399, February 2008: umbilical cord blood banking.

    Science.gov (United States)

    2008-02-01

    Two types of banks have emerged for the collection and storage of umbilical cord blood--public banks and private banks. Public banks promote allogenic (related or unrelated) donation, analogous to the current collection of whole blood units in the United States. Private banks were initially developed to store stem cells from umbilical cord blood for autologous use (taken from an individual for subsequent use by the same individual) by a child if the child develops disease later in life. If a patient requests information on umbilical cord blood banking, balanced and accurate information regarding the advantages and disadvantages of public versus private banking should be provided. The remote chance of an autologous unit of umbilical cord blood being used for a child or a family member (approximately 1 in 2,700 individuals) should be disclosed. The collection should not alter routine practice for the timing of umbilical cord clamping. Physicians or other professionals who recruit pregnant women and their families for for-profit umbilical cord blood banking should disclose any financial interests or other potential conflicts of interest.

  12. Electron Beam Polarization Measurement Using Touschek Lifetime Technique

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Changchun; /Duke U., DFELL; Li, Jingyi; /Duke U., DFELL; Mikhailov, Stepan; /Duke U., DFELL; Popov, Victor; /Duke U., DFELL; Wu, Wenzhong; /Duke U., DFELL; Wu, Ying; /Duke U., DFELL; Chao, Alex; /SLAC; Xu, Hong-liang; /Hefei, NSRL; Zhang, Jian-feng; /Hefei, NSRL

    2012-08-24

    Electron beam loss due to intra-beam scattering, the Touschek effect, in a storage ring depends on the electron beam polarization. The polarization of an electron beam can be determined from the difference in the Touschek lifetime compared with an unpolarized beam. In this paper, we report on a systematic experimental procedure recently developed at Duke FEL laboratory to study the radiative polarization of a stored electron beam. Using this technique, we have successfully observed the radiative polarization build-up of an electron beam in the Duke storage ring, and determined the equilibrium degree of polarization and the time constant of the polarization build-up process.

  13. Blood oxygen depletion is independent of dive function in a deep diving vertebrate, the northern elephant seal.

    Directory of Open Access Journals (Sweden)

    Jessica U Meir

    Full Text Available Although energetics is fundamental to animal ecology, traditional methods of determining metabolic rate are neither direct nor instantaneous. Recently, continuous blood oxygen (O2 measurements were used to assess energy expenditure in diving elephant seals (Mirounga angustirostris, demonstrating that an exceptional hypoxemic tolerance and exquisite management of blood O2 stores underlie the extraordinary diving capability of this consummate diver. As the detailed relationship of energy expenditure and dive behavior remains unknown, we integrated behavior, ecology, and physiology to characterize the costs of different types of dives of elephant seals. Elephant seal dive profiles were analyzed and O2 utilization was classified according to dive type (overall function of dive: transit, foraging, food processing/rest. This is the first account linking behavior at this level with in vivo blood O2 measurements in an animal freely diving at sea, allowing us to assess patterns of O2 utilization and energy expenditure between various behaviors and activities in an animal in the wild. In routine dives of elephant seals, the blood O2 store was significantly depleted to a similar range irrespective of dive function, suggesting that all dive types have equal costs in terms of blood O2 depletion. Here, we present the first physiological evidence that all dive types have similarly high blood O2 demands, supporting an energy balance strategy achieved by devoting one major task to a given dive, thereby separating dive functions into distinct dive types. This strategy may optimize O2 store utilization and recovery, consequently maximizing time underwater and allowing these animals to take full advantage of their underwater resources. This approach may be important to optimizing energy expenditure throughout a dive bout or at-sea foraging trip and is well suited to the lifestyle of an elephant seal, which spends > 90% of its time at sea submerged making diving its

  14. Effective Factors in Environmental Health Status of Grocery Stores

    Directory of Open Access Journals (Sweden)

    Mehdi Asadi

    2012-08-01

    Full Text Available Aims of the Study: This study was carried out to determine the effective factors in environmental health status of grocery stores in the city of Qom (located in the center of Iran. Materials & Methods: In this cross-sectional study, 283 grocery stores from 3 different regions were selected randomly using stratified sampling. Data were gathered through observation, interview, and questionnaire. The questionnaire consisted of two sections: section 1 dealt with some shop managers’ features including the age, educational level, job satisfaction, passing “food and occupational hygiene training courses”, store ownership, duration of employment, and features of stores including their location (Region and environmental health condition. And section 2 dealt with the important aspects of regulations of Article 13. The data analyzed using statistical procedures such as Spearman Rank Correlation and Multivariate Regression Analysis. P-values less than 0.05 were considered as statistically significant. Results: Among the investigated factors, the manager’s educational level had a greater impact on the environmental health conditions of grocery stores. The ownership status of grocery stores, Job satisfaction and passing “food and occupational hygiene training courses” were next in the ranking, respectively (p <0.001 for all measures, except for shop ownership, for which p-value was <0.02. Conclusions: Planning and implementation of effective operational and strategic programs addressing the above mentioned issues seems to be necessary. Such programs will improve the health status of the stores over time.

  15. A survey on consumers' attitude towards storing and end of life strategies of small information and communication technology devices in Spain.

    Science.gov (United States)

    Bovea, María D; Ibáñez-Forés, Valeria; Pérez-Belis, Victoria; Juan, Pablo

    2018-01-01

    This study analyses the current habits and practices towards the store, repair and second-hand purchase of small electrical and electronic devices belonging to the category of information and communication technology (ICT). To this end, a survey was designed and conducted with a representative sample size of 400 individuals through telephone interviews for the following categories: MP3/MP4, video camera, photo camera, mobile phone, tablet, e-book, laptop, hard disk drive, navigator-GPS, radio/radio alarm clock. According to the results obtained, there is a tendency to store disused small ICT devices at home. On average for all the small ICT categories analysed, 73.91% of the respondents store disused small ICT devices at home. Related to the habits towards the repair and second-hand purchase of small ICT devices, 65.5% and 87.6% of the respondents have never taken to repair and have never purchased second-hand, respectively, small ICT devices. This paper provides useful and hitherto unavailable information about the current habits of discarding and reusing ICT devices. It can be concluded that there is a need to implement awareness-raising campaigns to encourage these practices, which are necessary to reach the minimum goals established regarding preparation for reuse set out in the Directive 2012/19/EU for the category small electrical and electronic equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Store Format Choice in an Evolving Market . A TPB Approach

    OpenAIRE

    Singh, Kamaljit Anand; Sinha, Piyush Kumar

    2008-01-01

    The store choice has been studied extensively in the literature, but store format choice has had limited research attention. The store choice modeling has been primarily done in the random utility theory framework, which however is a neo-economics based view of choice decision that ignores the psychological and behavioral aspects of this planned behavior. The store format choice for bulk grocery purchase despite being a rational context has not been conceptualized in the most accepted constru...

  17. Storing of free neutrons

    International Nuclear Information System (INIS)

    Trinks, U.

    1978-12-01

    The applied method makes use of the interaction between the magnetic moment μ vector of the neutron and a magnetic field B vector. By means of superconducting magnets there can easily be achieved potential walls of μ B approximately 2 x 10 -7 eV. The principle of magnetic storing was first used for the storage ring NESTOR and showed immediate success: the stored neutrons decreased exponentially with a time constant tau = (907 +- 70) sec corresponding to the natural lifetime of the neutrons within the statistical errors. This means that there occurred no measurable additional losses (e.g. by resonance excitation) Neutrons therefore could be observed in the storage ring during about 5 half-lives (in principle of course longer, too). The orbit dynamics for neutrons in the storage ring is smilar to that in circular accelerators for charged particles. It is so well understood that the problem of the storage ring for uncharged particles (with magnetic moment) may be considered to e solved. (orig./HSI) [de

  18. Healthful Nutrition of Foods in Navajo Nation Stores: Availability and Pricing.

    Science.gov (United States)

    Kumar, Gayathri; Jim-Martin, Sonlatsa; Piltch, Emily; Onufrak, Stephen; McNeil, Carrie; Adams, Laura; Williams, Nancy; Blanck, Heidi M; Curley, Larry

    2016-09-01

    Low availability and affordability of healthier foods in food stores on the Navajo Nation (NN) may be a community-level risk factor for the high prevalence of obesity among the Navajo people. This study assessed the availability and pricing of foods and beverages in supermarkets and convenience stores throughout the NN. Descriptive study design using the Nutrition Environment Measurement Survey in Stores audit tool. Supermarkets (n = 13) and convenience stores (n = 50) on NN and border-town supermarkets (n = 9). Not applicable. Availability and pricing of healthy and less-healthy foods. Descriptive and χ(2) analyses. Navajo convenience stores offered fewer healthier food options compared to Navajo supermarkets. In Navajo convenience stores, 100% whole grain products, reduced-fat cheese, lean meats, reduced-fat chips, and fat-free or light hot dogs were available in fewer stores than their corresponding less-healthy versions (all with p foods are not as readily available in Navajo convenience stores as they are in Navajo supermarkets. Improving access to and affordability of healthier foods in reservation stores of all sizes may support healthy eating among Navajo residents. © 2016 by American Journal of Health Promotion, Inc.

  19. How to improve cord blood engraftment?

    Directory of Open Access Journals (Sweden)

    Meral eBeksac

    2016-02-01

    Full Text Available Various factors make cord blood (CB a significant source of hematopoietic stem cells (HSC, including ease of procurement and lack of donor attrition, with the ability to process and store the donor cells long term. Importantly, high proliferative potential of the immature HSCs allows one log less use of cells compared to bone marrow (BM or peripheral blood stem cells. As total nucleated cell (TNC and CD34 + cell content of CB grafts are correlated with engraftment rate and speed, strategies to expand HSC and homing have been developed. This chapter will focus on modalities such as intra-bone administration, fucosylation, CD26 inhibition, Prostaglandin G2 derivative or complement 3 exposure and SDF-1/CXCR4/CXCL-12 pathway interventions that have been experimented successfully. Furthermore increasing evidence in line with better recognition of CB progenitors that are involved in engraftment and homing will also be addressed.

  20. Control of stored-product pests by irradiation

    International Nuclear Information System (INIS)

    Mahbub Hasan; Khan, A.R.

    1998-01-01

    The present review deals with the effects of irradiation on some aspects of the biology of major stored-product pests, namely mortality, stages of development, reproductive organs and reproductive potential, histology of the gut, factors influencing irradiation and the synergism of irradiation with other control agents. It also reports on the irradiation effects on stored commodities. Further guidelines for future research have been suggested. (author)