WorldWideScience

Sample records for electronic nose applied

  1. Electronic Nose and Electronic Tongue

    Science.gov (United States)

    Bhattacharyya, Nabarun; Bandhopadhyay, Rajib

    Human beings have five senses, namely, vision, hearing, touch, smell and taste. The sensors for vision, hearing and touch have been developed for several years. The need for sensors capable of mimicking the senses of smell and taste have been felt only recently in food industry, environmental monitoring and several industrial applications. In the ever-widening horizon of frontier research in the field of electronics and advanced computing, emergence of electronic nose (E-Nose) and electronic tongue (E-Tongue) have been drawing attention of scientists and technologists for more than a decade. By intelligent integration of multitudes of technologies like chemometrics, microelectronics and advanced soft computing, human olfaction has been successfully mimicked by such new techniques called machine olfaction (Pearce et al. 2002). But the very essence of such research and development efforts has centered on development of customized electronic nose and electronic tongue solutions specific to individual applications. In fact, research trends as of date clearly points to the fact that a machine olfaction system as versatile, universal and broadband as human nose and human tongue may not be feasible in the decades to come. But application specific solutions may definitely be demonstrated and commercialized by modulation in sensor design and fine-tuning the soft computing solutions. This chapter deals with theory, developments of E-Nose and E-Tongue technology and their applications. Also a succinct account of future trends of R&D efforts in this field with an objective of establishing co-relation between machine olfaction and human perception has been included.

  2. Electronic Noses and Applications

    Directory of Open Access Journals (Sweden)

    Martine LUMBRERAS

    2014-05-01

    Full Text Available Electronic noses are customized devices employed to detect and to identify gaseous mixtures, even to give the concentration of the atmosphere components. Nowadays, the research in this domain is more and more growing, in Europe and other countries in the world, for many applications, such as environmental protection, food industries, perfumery, public safety, medicine, and pharmacy. Electronic noses allow to detect many organic volatile compounds, for which there is no specific detector. They constitute an alternative to complex, long, and too expensive existing methods, unable to ensure continuous monitoring. Their conception deals with many related areas (metrology, chemistry, physics, electronics, informatics, statistics, modelisation as well as areas related to the molecules to be detected. The system training is a primary step: during a measurement under a gaseous atmosphere, we must record the sensor time-responses in a treatment system, while specifying the name of the concerned odor. This process must be repeated many times for each studied atmosphere, and for all the chosen atmospheres. So a learning data base can be created, made from representative parameters of all the realized measures. After this training stage, clustering software will classify the data analysis in “concentration” or “nature” groups. Using the group separation rules given by this supervised classification, the system will be able to find itself the name of an odor or a concentration.

  3. Nose: Applied aspects in dermatology

    Directory of Open Access Journals (Sweden)

    Dammaningala Venkataramaiah Lakshmi

    2016-01-01

    Full Text Available Nose is the most prominent part of the mid-face and has important physiological, aesthetic and psychological functions. Skin diseases on the nose are commonly seen by dermatologists, otorhinolaryngologists, and plastic surgeons. Because of its exposed, highly visible localization, lesions on the skin of the nose are often noticed by patients themselves, typically very early in the course of the disease. Similarly, the dermatological lexicon is well known with descriptive terminologies, synonyms, acronyms, eponyms, toponyms, misnomers. We have tried to compile the anatomical applications of nose in cosmetology and dermatosurgery subspecialities with nasal eponyms and signs encountered in clinical dermatology that would be helpful for residents.

  4. Micro-Electronic Nose System

    Science.gov (United States)

    Zee, Frank C.

    2011-12-01

    at low gas concentrations between 100 and 600 ppm for two gas vapors and the other at high gas concentrations between 2000 ppm and the saturated vapor pressure of three gas vapors. The array of sensors and circuits were able to uniquely detect and measure these gas vapors and showed a linear response to their concentration levels for both experiments. The results also demonstrated that a reduction in the sensor area by two orders of magnitude (from 4.32 mm² to 0.0625 mm²) did not affect the sensor response. By applying pattern-recognition algorithms, the electronic nose system was able to correctly identify the different gas vapors from the pattern responses of the sensor array.

  5. Electronic Noses and Tongues in Wine Industry

    Directory of Open Access Journals (Sweden)

    Maria Luz Rodriguez-Mendez

    2016-10-01

    Full Text Available The quality of wines is usually evaluated by a sensory panel formed of trained experts or traditional chemical analysis. Over the last few decades, electronic noses and electronic tongues have been developed to determine the quality of foods and beverages. They consist of arrays of sensors with cross-sensitivity, combined with pattern recognition software, which provide a fingerprint of the samples that can be used to discriminate or classify the samples. This holistic approach is inspired by the method used in mammals to recognize food through their senses. They have been widely applied to the analysis of wines, including quality control, aging control or the detection of fraudulence, among others. In this paper, the current status of research and development in the field of electronic noses and tongues applied to the analysis of wines is reviewed. Their potential applications in the wine industry are described. The review ends with a final comment about expected future developments.

  6. Applications and advances in electronic-nose technologies

    Science.gov (United States)

    A. D. Wilson; M. Baietto

    2009-01-01

    Electronic-nose devices have received considerable attention in the field of sensor technology during the past twenty years, largely due to the discovery of numerous applications derived from research in diverse fields of applied sciences. Recent applications of electronic nose technologies have come through advances in sensor design, material improvements, software...

  7. Electronic Nose Technology and its Applications

    Directory of Open Access Journals (Sweden)

    Esmaeil MAHMOUDI

    2009-08-01

    Full Text Available In the past decade, Electronic Nose instrumentation has generated much interest internationally for its potential to solve a wide variety of problems in fragrance and cosmetics production, food and beverages manufacturing, chemical engineering, environmental monitoring and more recently medical diagnostic, bioprocesses and clinical diagnostic plant diseases. This instrument measure electrical resistance changes generated by adsorption of volatiles to the surface of electro active- polymer coated sensor- unique digital electronic fingerprint of aroma derived from multi-sensor- responses to distinct mixture of microbial volatiles. Major advances in information and gas sensor technology could enhance the diagnostic power of future bio-electronic nose and facilitate global surveillance mode of disease control and management. Several dozen companies are now designed and selling electronic nose units globally for a wide variety of expending markets. The present review includes principles of electronic nose technology, biosensor structure and applications of electronic nose in many fields.

  8. Electronic nose in edible insects area

    OpenAIRE

    Martin Adámek; Anna Adámková; Marie Borkovcová; Jiří Mlček; Martina Bednářová; Lenka Kouřimská; Josef Skácel; Michal Řezníček

    2017-01-01

    Edible insect is appraised by many cultures as delicious and nutritionally beneficial food. In western countries this commodity is not fully appreciated, and the worries about edible insect food safety prevail. Electronic noses can become a simple and cheap way of securing the health safety of food, and they can also become a tool for evaluating the quality of certain commodities. This research is a pilot project of using an electronic nose in edible insect culinary treatment, and this manusc...

  9. Applications of electronic noses in meat analysis

    Directory of Open Access Journals (Sweden)

    Elżbieta GÓRSKA-HORCZYCZAK

    2016-01-01

    Full Text Available Abstract Electronic noses are devices able to characterize and differentiate the aroma profiles of various food, especially meat and meat products. During recent years e-noses have been widely used in food analysis and proved to provide a fast, simple, non-expensive and non-destructive method of food assessment and quality control. The aim of this study is to summarize the most important features of this analytic tool and to present basic fields and typical areas of e-nose use as well as most commonly used sensor types and patterns for e-nose design. Prospects for the future development of this technique are presented. Methods and research results presented in this manuscript may be a guideline for practical e-nose use.

  10. Applications and Advances in Electronic-Nose Technologies

    Directory of Open Access Journals (Sweden)

    Manuela Baietto

    2009-06-01

    Full Text Available Electronic-nose devices have received considerable attention in the field of sensor technology during the past twenty years, largely due to the discovery of numerous applications derived from research in diverse fields of applied sciences. Recent applications of electronic nose technologies have come through advances in sensor design, material improvements, software innovations and progress in microcircuitry design and systems integration. The invention of many new e-nose sensor types and arrays, based on different detection principles and mechanisms, is closely correlated with the expansion of new applications. Electronic noses have provided a plethora of benefits to a variety of commercial industries, including the agricultural, biomedical, cosmetics, environmental, food, manufacturing, military, pharmaceutical, regulatory, and various scientific research fields. Advances have improved product attributes, uniformity, and consistency as a result of increases in quality control capabilities afforded by electronic-nose monitoring of all phases of industrial manufacturing processes. This paper is a review of the major electronic-nose technologies, developed since this specialized field was born and became prominent in the mid 1980s, and a summarization of some of the more important and useful applications that have been of greatest benefit to man.

  11. Electronic nose in edible insects area

    Directory of Open Access Journals (Sweden)

    Martin Adámek

    2017-01-01

    Full Text Available Edible insect is appraised by many cultures as delicious and nutritionally beneficial food. In western countries this commodity is not fully appreciated, and the worries about edible insect food safety prevail. Electronic noses can become a simple and cheap way of securing the health safety of food, and they can also become a tool for evaluating the quality of certain commodities. This research is a pilot project of using an electronic nose in edible insect culinary treatment, and this manuscript describes the phases of edible insect culinary treatment and methods of distinguishing mealworm (Tenebrio molitor and giant mealworm (Zophobas morio using simple electronic nose. These species were measured in the live stage, after killing with boiling water, after drying and after inserting into the chocolate.The sensing device was based on the Arduino Mega platform with the ability to store the recorded data on the SD memory card, and with the possibility to communicate via internet. Data analysis shows that even a simple, cheap and portable electronic nose can distinguish between the different steps of culinary treatment (native samples, dried samples, samples enriched with chocolate for cooking and selected species. Another benefit of the electronic nose could be its future introduction into the control mechanisms of food security systems (e.g. HACCP.

  12. Toward a minituarized low-power micromechanical electronic nose

    NARCIS (Netherlands)

    Karabaçak, D.; Sieben-Xu, L.; Vandecasteele, M.; Andel, Y. van; Wouters, D.; Calama, M.C.; Brongersma, S.H.

    2012-01-01

    An electronic nose based on an array of vibrating doubly clamped beams is proposed. These very high aspect ratio (length/thickness) suspended resonators can be individually functionalized by applying polymer coatings with an inkjet printing approach. The absorption of volatile compounds induces a

  13. Handbook of Machine Olfaction: Electronic Nose Technology

    Science.gov (United States)

    Pearce, Tim C.; Schiffman, Susan S.; Nagle, H. Troy; Gardner, Julian W.

    2003-02-01

    "Electronic noses" are instruments which mimic the sense of smell. Consisting of olfactory sensors and a suitable signal processing unit, they are able to detect and distinguish odors precisely and at low cost. This makes them very useful for a remarkable variety of applications in the food and pharmaceutical industry, in environmental control or clinical diagnostics and more. The scope covers biological and technical fundamentals and up-to-date research. Contributions by renowned international scientists as well as application-oriented news from successful "e-nose" manufacturers give a well-rounded account of the topic, and this coverage from R&D to applications makes this book a must-have read for e-nose researchers, designers and users alike.

  14. Sensors: From Biosensors to the Electronic Nose

    OpenAIRE

    García-González, Diego L.; Aparicio López, Ramón

    2002-01-01

    The recent advances in sensor devices have allowed the developing of new applications in many technological fields. This review describes the current state-of-the-art of this sensor technology, placing special emphasis on the food applications. The design, technology and sensing mechanism of each type of sensor are analysed. A description of the main characteristics of the electronic nose and electronic tongue (taste sensors) is also given. Finally, the applications of some statistical pro...

  15. Sensors: From biosensors to the electronic nose

    OpenAIRE

    Aparicio, Ramón; García-González, Diego L.

    2002-01-01

    The recent advances in sensor devices have allowed the developing of new applications in many technological fields. This review describes the current state-of-the-art of this sensor technology, placing special emphasis on the food applications. The design, technology and sensing mechanism of each type of sensor are analysed. A description of the main characteristics of the electronic nose and electronic tongue (taste sensors) is also given. Finally, the applications of some statistical proced...

  16. Miniature sensor suitable for electronic nose applications

    DEFF Research Database (Denmark)

    Pinnaduwage, L. A.; Gehl, A. C.; Allman, S. L.

    2007-01-01

    A major research effort has been devoted over the years for the development of chemical sensors for the detection of chemical and explosive vapors. However, the deployment of such chemical sensors will require the use of multiple sensors probably tens of sensors in a sensor package to achieve sel...... microcantilevers. The sensor can detect parts-per-trillion concentrations of DMMP within 10 s exposure times. The small size of the sensor makes it ideally suited for electronic nose applications. © 2007 American Institute of Physics....

  17. Towards a Chemiresistive Sensor-Integrated Electronic Nose: A Review

    Directory of Open Access Journals (Sweden)

    Kea-Tiong Tang

    2013-10-01

    Full Text Available Electronic noses have potential applications in daily life, but are restricted by their bulky size and high price. This review focuses on the use of chemiresistive gas sensors, metal-oxide semiconductor gas sensors and conductive polymer gas sensors in an electronic nose for system integration to reduce size and cost. The review covers the system design considerations and the complementary metal-oxide-semiconductor integrated technology for a chemiresistive gas sensor electronic nose, including the integrated sensor array, its readout interface, and pattern recognition hardware. In addition, the state-of-the-art technology integrated in the electronic nose is also presented, such as the sensing front-end chip, electronic nose signal processing chip, and the electronic nose system-on-chip.

  18. Bacteria classification using Cyranose 320 electronic nose

    Directory of Open Access Journals (Sweden)

    Gardner Julian W

    2002-10-01

    Full Text Available Abstract Background An electronic nose (e-nose, the Cyrano Sciences' Cyranose 320, comprising an array of thirty-two polymer carbon black composite sensors has been used to identify six species of bacteria responsible for eye infections when present at a range of concentrations in saline solutions. Readings were taken from the headspace of the samples by manually introducing the portable e-nose system into a sterile glass containing a fixed volume of bacteria in suspension. Gathered data were a very complex mixture of different chemical compounds. Method Linear Principal Component Analysis (PCA method was able to classify four classes of bacteria out of six classes though in reality other two classes were not better evident from PCA analysis and we got 74% classification accuracy from PCA. An innovative data clustering approach was investigated for these bacteria data by combining the 3-dimensional scatter plot, Fuzzy C Means (FCM and Self Organizing Map (SOM network. Using these three data clustering algorithms simultaneously better 'classification' of six eye bacteria classes were represented. Then three supervised classifiers, namely Multi Layer Perceptron (MLP, Probabilistic Neural network (PNN and Radial basis function network (RBF, were used to classify the six bacteria classes. Results A [6 × 1] SOM network gave 96% accuracy for bacteria classification which was best accuracy. A comparative evaluation of the classifiers was conducted for this application. The best results suggest that we are able to predict six classes of bacteria with up to 98% accuracy with the application of the RBF network. Conclusion This type of bacteria data analysis and feature extraction is very difficult. But we can conclude that this combined use of three nonlinear methods can solve the feature extraction problem with very complex data and enhance the performance of Cyranose 320.

  19. Rapid lard identification with portable electronic nose

    Science.gov (United States)

    Latief, Marsad; Khorsidtalab, Aida; Saputra, Irwan; Akmeliawati, Rini; Nurashikin, Anis; Jaswir, Irwandi; Witjaksono, Gunawan

    2017-11-01

    Human sensory systems are limited in many different regards, yet they are great sources of inspiration for development of technologies that help humans to overcome their restraints. This paper signifies the capability of our developed electronic nose in rapid lard identification. The developed device, known as E-Nose, mimics human’s olfactory system’s technique to identify a particular substance. Lard is a common pig derivative which is often used as a food additive, emulsion or shortening. It’s also commonly used as an adulterant or as an alternative for cooking oils, margarine and butter. This substance is prohibited to be consumed by Muslims and Orthodox Jews for religious reasons. A portable reliable device with an ability to identify lard rapidly can be convenient to users concerned about lard adulteration. The prototype was examined using K-Nearest Neighbors algorithm (KNN), Support Vector Machine (SVM), Bagged Trees and Simple Tree, and can identify lard with the highest accuracy of 95.6% among three types of fat (lard, chicken and beef) in liquid form over a certain range of temperature using KNN.

  20. Classification of buildings mold threat using electronic nose

    Science.gov (United States)

    Łagód, Grzegorz; Suchorab, Zbigniew; Guz, Łukasz; Sobczuk, Henryk

    2017-07-01

    Mold is considered to be one of the most important features of Sick Building Syndrome and is an important problem in current building industry. In many cases it is caused by the rising moisture of building envelopes surface and exaggerated humidity of indoor air. Concerning historical buildings it is mostly caused by outdated raising techniques among that is absence of horizontal isolation against moisture and hygroscopic materials applied for construction. Recent buildings also suffer problem of mold risk which is caused in many cases by hermetization leading to improper performance of gravitational ventilation systems that make suitable conditions for mold development. Basing on our research there is proposed a method of buildings mold threat classification using electronic nose, based on a gas sensors array which consists of MOS sensors (metal oxide semiconductor). Used device is frequently applied for air quality assessment in environmental engineering branches. Presented results show the interpretation of e-nose readouts of indoor air sampled in rooms threatened with mold development in comparison with clean reference rooms and synthetic air. Obtained multivariate data were processed, visualized and classified using a PCA (Principal Component Analysis) and ANN (Artificial Neural Network) methods. Described investigation confirmed that electronic nose - gas sensors array supported with data processing enables to classify air samples taken from different rooms affected with mold.

  1. Potential Applications and Limitations of Electronic Nose Devices for Plant Disease Diagnosis

    Directory of Open Access Journals (Sweden)

    Antonio Cellini

    2017-11-01

    Full Text Available Electronic nose technology has recently been applied to the detection of several plant diseases and pests, with promising results. However, in spite of its numerous advantages, including operational simplicity, non-destructivity, and bulk sampling, drawbacks include a low sensitivity and specificity in comparison with microbiological and molecular methods. A critical review of the use of an electronic nose for plant disease diagnosis and pest detection is presented, describing the instrumental and procedural advances of sensorial analysis, for the improvement of discrimination between healthy and infected or infested plants. In conclusion, the use of electronic nose technology is suggested to assist, direct, and optimise traditionally adopted diagnostic techniques.

  2. Sensors: From biosensors to the electronic nose

    Directory of Open Access Journals (Sweden)

    Aparicio, Ramón

    2002-03-01

    Full Text Available The recent advances in sensor devices have allowed the developing of new applications in many technological fields. This review describes the current state-of-the-art of this sensor technology, placing special emphasis on the food applications. The design, technology and sensing mechanism of each type of sensor are analysed. A description of the main characteristics of the electronic nose and electronic tongue (taste sensors is also given. Finally, the applications of some statistical procedures in sensor systems are described briefly.Los recientes avances en los sistemas de sensores han permitido el desarrollo de nuevas aplicaciones en muchos campos tecnológicos. Este artículo de revisión describe el estado actual de esta nueva tecnología, con especial énfasis en las aplicaciones alimentarias. El diseño, la tecnología y el mecanismo sensorial de cada tipo de sensor son analizados en el artículo. También se describen las principales características de la nariz y la lengua electrónica (sensores de sabor. Finalmente, se describe brevemente el uso de algunos procedimientos estadísticos en sistemas de sensores.

  3. Advances in electronic-nose technologies developed for biomedical applications

    Science.gov (United States)

    Dan Wilson; Manuela. Baietto

    2011-01-01

    The research and development of new electronic-nose applications in the biomedical field has accelerated at a phenomenal rate over the past 25 years. Many innovative e-nose technologies have provided solutions and applications to a wide variety of complex biomedical and healthcare problems. The purposes of this review are to present a comprehensive analysis of past and...

  4. Quality Evaluation of Agricultural Distillates Using an Electronic Nose

    OpenAIRE

    Dymerski, Tomasz; Gębicki, Jacek; Wardencki, Waldemar; Namieśnik, Jacek

    2013-01-01

    The paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction of the agricultural distillate samples differing ...

  5. Advances in electronic-nose technologies developed for biomedical applications.

    Science.gov (United States)

    Wilson, Alphus D; Baietto, Manuela

    2011-01-01

    The research and development of new electronic-nose applications in the biomedical field has accelerated at a phenomenal rate over the past 25 years. Many innovative e-nose technologies have provided solutions and applications to a wide variety of complex biomedical and healthcare problems. The purposes of this review are to present a comprehensive analysis of past and recent biomedical research findings and developments of electronic-nose sensor technologies, and to identify current and future potential e-nose applications that will continue to advance the effectiveness and efficiency of biomedical treatments and healthcare services for many years. An abundance of electronic-nose applications has been developed for a variety of healthcare sectors including diagnostics, immunology, pathology, patient recovery, pharmacology, physical therapy, physiology, preventative medicine, remote healthcare, and wound and graft healing. Specific biomedical e-nose applications range from uses in biochemical testing, blood-compatibility evaluations, disease diagnoses, and drug delivery to monitoring of metabolic levels, organ dysfunctions, and patient conditions through telemedicine. This paper summarizes the major electronic-nose technologies developed for healthcare and biomedical applications since the late 1980s when electronic aroma detection technologies were first recognized to be potentially useful in providing effective solutions to problems in the healthcare industry.

  6. Advances in Electronic-Nose Technologies Developed for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Alphus D. Wilson

    2011-01-01

    Full Text Available The research and development of new electronic-nose applications in the biomedical field has accelerated at a phenomenal rate over the past 25 years. Many innovative e-nose technologies have provided solutions and applications to a wide variety of complex biomedical and healthcare problems. The purposes of this review are to present a comprehensive analysis of past and recent biomedical research findings and developments of electronic-nose sensor technologies, and to identify current and future potential e-nose applications that will continue to advance the effectiveness and efficiency of biomedical treatments and healthcare services for many years. An abundance of electronic-nose applications has been developed for a variety of healthcare sectors including diagnostics, immunology, pathology, patient recovery, pharmacology, physical therapy, physiology, preventative medicine, remote healthcare, and wound and graft healing. Specific biomedical e-nose applications range from uses in biochemical testing, blood-compatibility evaluations, disease diagnoses, and drug delivery to monitoring of metabolic levels, organ dysfunctions, and patient conditions through telemedicine. This paper summarizes the major electronic-nose technologies developed for healthcare and biomedical applications since the late 1980s when electronic aroma detection technologies were first recognized to be potentially useful in providing effective solutions to problems in the healthcare industry.

  7. A Compact and Low Cost Electronic Nose for Aroma Detection

    Directory of Open Access Journals (Sweden)

    Ramón Gallardo Caballero

    2013-04-01

    Full Text Available This article explains the development of a prototype of a portable and a very low-cost electronic nose based on an mbed microcontroller. Mbeds are a series of ARM microcontroller development boards designed for fast, flexible and rapid prototyping. The electronic nose is comprised of an mbed, an LCD display, two small pumps, two electro-valves and a sensor chamber with four TGS Figaro gas sensors. The performance of the electronic nose has been tested by measuring the ethanol content of wine synthetic matrices and special attention has been paid to the reproducibility and repeatability of the measurements taken on different days. Results show that the electronic nose with a neural network classifier is able to discriminate wine samples with 10, 12 and 14% V/V alcohol content with a classification error of less than 1%.

  8. Electronic Nose Odor Classification with Advanced Decision Tree Structures

    Directory of Open Access Journals (Sweden)

    S. Guney

    2013-09-01

    Full Text Available Electronic nose (e-nose is an electronic device which can measure chemical compounds in air and consequently classify different odors. In this paper, an e-nose device consisting of 8 different gas sensors was designed and constructed. Using this device, 104 different experiments involving 11 different odor classes (moth, angelica root, rose, mint, polis, lemon, rotten egg, egg, garlic, grass, and acetone were performed. The main contribution of this paper is the finding that using the chemical domain knowledge it is possible to train an accurate odor classification system. The domain knowledge about chemical compounds is represented by a decision tree whose nodes are composed of classifiers such as Support Vector Machines and k-Nearest Neighbor. The overall accuracy achieved with the proposed algorithm and the constructed e-nose device was 97.18 %. Training and testing data sets used in this paper are published online.

  9. Graphene-Based Chemical Vapor Sensors for Electronic Nose Applications

    Science.gov (United States)

    Nallon, Eric C.

    An electronic nose (e-nose) is a biologically inspired device designed to mimic the operation of the olfactory system. The e-nose utilizes a chemical sensor array consisting of broadly responsive vapor sensors, whose combined response produces a unique pattern for a given compound or mixture. The sensor array is inspired by the biological function of the receptor neurons found in the human olfactory system, which are inherently cross-reactive and respond to many different compounds. The use of an e-nose is an attractive approach to predict unknown odors and is used in many fields for quantitative and qualitative analysis. If properly designed, an e-nose has the potential to adapt to new odors it was not originally designed for through laboratory training and algorithm updates. This would eliminate the lengthy and costly R&D costs associated with materiel and product development. Although e-nose technology has been around for over two decades, much research is still being undertaken in order to find new and more diverse types of sensors. Graphene is a single-layer, 2D material comprised of carbon atoms arranged in a hexagonal lattice, with extraordinary electrical, mechanical, thermal and optical properties due to its 2D, sp2-bonded structure. Graphene has much potential as a chemical sensing material due to its 2D structure, which provides a surface entirely exposed to its surrounding environment. In this configuration, every carbon atom in graphene is a surface atom, providing the greatest possible surface area per unit volume, so that electron transport is highly sensitive to adsorbed molecular species. Graphene has gained much attention since its discovery in 2004, but has not been realized in many commercial electronics. It has the potential to be a revolutionary material for use in chemical sensors due to its excellent conductivity, large surface area, low noise, and versatile surface for functionalization. In this work, graphene is incorporated into a

  10. A Hybrid System Based on an Electronic Nose Coupled with an Electronic Tongue for the Characterization of Moroccan Waters

    Directory of Open Access Journals (Sweden)

    Z. Haddi

    2014-05-01

    Full Text Available A hybrid multisensor system combined with multivariate analysis was applied to the characterization of different kinds of Moroccan waters. The proposed hybrid system based on an electronic nose coupled with an electronic tongue consisted of metal oxide semiconductors and potentiometric sensors respectively. Five Taguchi Gas Sensors were implemented in the electronic nose for the discrimination between mineral, natural, sparkling, river and tap waters. Afterwards, the electronic tongue, based on series of Ion-Selective-Electrodes was applied to the analysis of the same waters. Multisensor responses obtained from the waters were processed by two chemometrics: Principal Component Analysis (PCA and Linear Discriminant Analysis (LDA. PCA results using electronic nose data depict all of the potable water samples in a separate group from the samples that were originated from river. Furthermore, PCA and LDA analysis on electronic tongue data permitted clear and rapid recognizing of the different waters due to the concentration changes of the chemical parameters from source to another.

  11. A new kernel discriminant analysis framework for electronic nose recognition

    International Nuclear Information System (INIS)

    Zhang, Lei; Tian, Feng-Chun

    2014-01-01

    Graphical abstract: - Highlights: • This paper proposes a new discriminant analysis framework for feature extraction and recognition. • The principle of the proposed NDA is derived mathematically. • The NDA framework is coupled with kernel PCA for classification. • The proposed KNDA is compared with state of the art e-Nose recognition methods. • The proposed KNDA shows the best performance in e-Nose experiments. - Abstract: Electronic nose (e-Nose) technology based on metal oxide semiconductor gas sensor array is widely studied for detection of gas components. This paper proposes a new discriminant analysis framework (NDA) for dimension reduction and e-Nose recognition. In a NDA, the between-class and the within-class Laplacian scatter matrix are designed from sample to sample, respectively, to characterize the between-class separability and the within-class compactness by seeking for discriminant matrix to simultaneously maximize the between-class Laplacian scatter and minimize the within-class Laplacian scatter. In terms of the linear separability in high dimensional kernel mapping space and the dimension reduction of principal component analysis (PCA), an effective kernel PCA plus NDA method (KNDA) is proposed for rapid detection of gas mixture components by an e-Nose. The NDA framework is derived in this paper as well as the specific implementations of the proposed KNDA method in training and recognition process. The KNDA is examined on the e-Nose datasets of six kinds of gas components, and compared with state of the art e-Nose classification methods. Experimental results demonstrate that the proposed KNDA method shows the best performance with average recognition rate and total recognition rate as 94.14% and 95.06% which leads to a promising feature extraction and multi-class recognition in e-Nose

  12. Future applications of electronic-nose technologies in healthcare and biomedicine

    Science.gov (United States)

    Alphus D. Wilson

    2011-01-01

    The development and utilization of many new electronic-nose (e-nose) applications in the healthcare and biomedical fields have continued to rapidly accelerate over the past 20 years. Innovative e-nose technologies are providing unique solutions to a diversity of complex problems in biomedicine that are now coming to fruition. A wide range of electronic-nose instrument...

  13. Determination of authenticity of brand perfume using electronic nose prototypes

    International Nuclear Information System (INIS)

    Gebicki, Jacek; Szulczynski, Bartosz; Kaminski, Marian

    2015-01-01

    The paper presents the practical application of an electronic nose technique for fast and efficient discrimination between authentic and fake perfume samples. Two self-built electronic nose prototypes equipped with a set of semiconductor sensors were employed for that purpose. Additionally 10 volunteers took part in the sensory analysis. The following perfumes and their fake counterparts were analysed: Dior—Fahrenheit, Eisenberg—J’ose, YSL—La nuit de L’homme, 7 Loewe and Spice Bomb. The investigations were carried out using the headspace of the aqueous solutions. Data analysis utilized multidimensional techniques: principle component analysis (PCA), linear discrimination analysis (LDA), k-nearest neighbour (k-NN). The results obtained confirmed the legitimacy of the electronic nose technique as an alternative to the sensory analysis as far as the determination of authenticity of perfume is concerned. (paper)

  14. Determination of authenticity of brand perfume using electronic nose prototypes

    Science.gov (United States)

    Gebicki, Jacek; Szulczynski, Bartosz; Kaminski, Marian

    2015-12-01

    The paper presents the practical application of an electronic nose technique for fast and efficient discrimination between authentic and fake perfume samples. Two self-built electronic nose prototypes equipped with a set of semiconductor sensors were employed for that purpose. Additionally 10 volunteers took part in the sensory analysis. The following perfumes and their fake counterparts were analysed: Dior—Fahrenheit, Eisenberg—J’ose, YSL—La nuit de L’homme, 7 Loewe and Spice Bomb. The investigations were carried out using the headspace of the aqueous solutions. Data analysis utilized multidimensional techniques: principle component analysis (PCA), linear discrimination analysis (LDA), k-nearest neighbour (k-NN). The results obtained confirmed the legitimacy of the electronic nose technique as an alternative to the sensory analysis as far as the determination of authenticity of perfume is concerned.

  15. Identification of Chinese Herbal Medicines with Electronic Nose Technology: Applications and Challenges

    Directory of Open Access Journals (Sweden)

    Huaying Zhou

    2017-05-01

    Full Text Available This paper provides a review of the most recent works in machine olfaction as applied to the identification of Chinese Herbal Medicines (CHMs. Due to the wide variety of CHMs, the complexity of growing sources and the diverse specifications of herb components, the quality control of CHMs is a challenging issue. Much research has demonstrated that an electronic nose (E-nose as an advanced machine olfaction system, can overcome this challenge through identification of the complex odors of CHMs. E-nose technology, with better usability, high sensitivity, real-time detection and non-destructive features has shown better performance in comparison with other analytical techniques such as gas chromatography-mass spectrometry (GC-MS. Although there has been immense development of E-nose techniques in other applications, there are limited reports on the application of E-noses for the quality control of CHMs. The aim of current study is to review practical implementation and advantages of E-noses for robust and effective odor identification of CHMs. It covers the use of E-nose technology to study the effects of growing regions, identification methods, production procedures and storage time on CHMs. Moreover, the challenges and applications of E-nose for CHM identification are investigated. Based on the advancement in E-nose technology, odor may become a new quantitative index for quality control of CHMs and drug discovery. It was also found that more research could be done in the area of odor standardization and odor reproduction for remote sensing.

  16. Identification of Chinese Herbal Medicines with Electronic Nose Technology: Applications and Challenges.

    Science.gov (United States)

    Zhou, Huaying; Luo, Dehan; GholamHosseini, Hamid; Li, Zhong; He, Jiafeng

    2017-05-09

    This paper provides a review of the most recent works in machine olfaction as applied to the identification of Chinese Herbal Medicines (CHMs). Due to the wide variety of CHMs, the complexity of growing sources and the diverse specifications of herb components, the quality control of CHMs is a challenging issue. Much research has demonstrated that an electronic nose (E-nose) as an advanced machine olfaction system, can overcome this challenge through identification of the complex odors of CHMs. E-nose technology, with better usability, high sensitivity, real-time detection and non-destructive features has shown better performance in comparison with other analytical techniques such as gas chromatography-mass spectrometry (GC-MS). Although there has been immense development of E-nose techniques in other applications, there are limited reports on the application of E-noses for the quality control of CHMs. The aim of current study is to review practical implementation and advantages of E-noses for robust and effective odor identification of CHMs. It covers the use of E-nose technology to study the effects of growing regions, identification methods, production procedures and storage time on CHMs. Moreover, the challenges and applications of E-nose for CHM identification are investigated. Based on the advancement in E-nose technology, odor may become a new quantitative index for quality control of CHMs and drug discovery. It was also found that more research could be done in the area of odor standardization and odor reproduction for remote sensing.

  17. Assessment of compost maturity by using an electronic nose.

    Science.gov (United States)

    López, Rafael; Giráldez, Inmaculada; Palma, Alberto; Jesús Díaz, M

    2016-02-01

    The composting process produces and emits hundreds of different gases. Volatile organic compounds (VOCs) can provide information about progress of composting process. This paper is focused on the qualitative and quantitative relationships between compost age, as sign of compost maturity, electronic-nose (e-nose) patterns and composition of compost and composting gas at an industrial scale plant. Gas and compost samples were taken at different depths from composting windrows of different ages. Temperature, classical chemical parameters, O2, CO, combustible gases, VOCs and e-nose profiles were determined and related using principal component analysis (PCA). Factor analysis carried out to a data set including compost physical-chemical properties, pile pore gas composition and composting time led to few factors, each one grouping together standard composting parameters in an easy to understand way. PCA obtained from e-nose profiles allowed the classifying of piles, their aerobic-anaerobic condition, and a rough estimation of the composting time. That would allow for immediate and in-situ assessment of compost quality and maturity by using an on-line e-nose. The e-nose patterns required only 3-4 sensor signals to account for a great percentage (97-98%) of data variance. The achieved patterns both from compost (chemical analysis) and gas (e-nose analysis) samples are robust despite the high variability in feedstock characteristics (3 different materials), composting conditions and long composting time. GC-MS chromatograms supported the patterns. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Using Electronic Noses to Detect Tumors During Neurosurgery

    Science.gov (United States)

    Homer, Margie L.; Ryan, Margaret A.; Lara, Liana M.; Kateb, Babak; Chen, Mike

    2008-01-01

    It has been proposed to develop special-purpose electronic noses and algorithms for processing the digitized outputs of the electronic noses for determining whether tissue exposed during neurosurgery is cancerous. At present, visual inspection by a surgeon is the only available intraoperative technique for detecting cancerous tissue. Implementation of the proposal would help to satisfy a desire, expressed by some neurosurgeons, for an intraoperative technique for determining whether all of a brain tumor has been removed. The electronic-nose technique could complement multimodal imaging techniques, which have also been proposed as means of detecting cancerous tissue. There are also other potential applications of the electronic-nose technique in general diagnosis of abnormal tissue. In preliminary experiments performed to assess the viability of the proposal, the problem of distinguishing between different types of cultured cells was substituted for the problem of distinguishing between normal and abnormal specimens of the same type of tissue. The figure presents data from one experiment, illustrating differences between patterns that could be used to distinguish between two types of cultured cancer cells. Further development can be expected to include studies directed toward answering questions concerning not only the possibility of distinguishing among various types of normal and abnormal tissue but also distinguishing between tissues of interest and other odorous substances that may be present in medical settings.

  19. Monitoring of alcoholic fermentation using near infrared and mid infrared spectroscopies combined with electronic nose and electronic tongue

    International Nuclear Information System (INIS)

    Buratti, S.; Ballabio, D.; Giovanelli, G.; Dominguez, C.M. Zuluanga; Moles, A.; Benedetti, S.; Sinelli, N.

    2011-01-01

    Graphical abstract: Application of non destructive methods for the monitoring of red wine fermentation in correlation with the evolution of chemical parameters. Highlights: → We monitored time-related changes in red wine fermentation process. → NIR and MIR spectroscopies, electronic nose and tongue were applied. → Data were kinetically modelled to identify critical points during fermentation. → NIR, MIR electronic nose and tongue were able to follow the fermentation process. → The models agreed with the evolution of chemical parameters. - Abstract: Effective fermentation monitoring is a growing need due to the rapid pace of change in the wine industry, which calls for fast methods providing real time information in order to assure the quality of the final product. The objective of this work is to investigate the potential of non-destructive techniques associated with chemometric data analysis, to monitor time-related changes that occur during red wine fermentation. Eight micro-fermentation trials conducted in the Valtellina region (Northern Italy) during the 2009 vintage, were monitored by a FT-NIR and a FT-IR spectrometer and by an electronic nose and tongue. The spectroscopic technique was used to investigate molecular changes, while electronic nose and electronic tongue evaluated the evolution of the aroma and taste profile during the must-wine fermentation. Must-wine samples were also analysed by traditional chemical methods in order to determine sugars (glucose and fructose) consumption and alcohol (ethanol and glycerol) production. Principal Component Analysis was applied to spectral, electronic nose and electronic tongue data, as an exploratory tool, to uncover molecular, aroma and taste modifications during the fermentation process. Furthermore, the chemical data and the PC1 scores from spectral, electronic nose and electronic tongue data were modelled as a function of time to identify critical points during fermentation. The results showed that

  20. Monitoring of alcoholic fermentation using near infrared and mid infrared spectroscopies combined with electronic nose and electronic tongue

    Energy Technology Data Exchange (ETDEWEB)

    Buratti, S., E-mail: susanna.buratti@unimi.it [Department of Food Science and Technology, Universita degli Studi di Milano, Via Celoria 2, 20133 Milano (Italy); Ballabio, D. [Department of Environmental Sciences, University of Milano-Bicocca, Piazza della Scienza 1, 20126 Milano (Italy); Giovanelli, G. [Department of Food Science and Technology, Universita degli Studi di Milano, Via Celoria 2, 20133 Milano (Italy); Dominguez, C.M. Zuluanga [Instituto de Ciencia y Tecnologia de Alimentos, Universidad Nacional de Colombia, Ciudad Universitaria, Bogota (Colombia); Moles, A.; Benedetti, S.; Sinelli, N. [Department of Food Science and Technology, Universita degli Studi di Milano, Via Celoria 2, 20133 Milano (Italy)

    2011-07-04

    Graphical abstract: Application of non destructive methods for the monitoring of red wine fermentation in correlation with the evolution of chemical parameters. Highlights: > We monitored time-related changes in red wine fermentation process. > NIR and MIR spectroscopies, electronic nose and tongue were applied. > Data were kinetically modelled to identify critical points during fermentation. > NIR, MIR electronic nose and tongue were able to follow the fermentation process. > The models agreed with the evolution of chemical parameters. - Abstract: Effective fermentation monitoring is a growing need due to the rapid pace of change in the wine industry, which calls for fast methods providing real time information in order to assure the quality of the final product. The objective of this work is to investigate the potential of non-destructive techniques associated with chemometric data analysis, to monitor time-related changes that occur during red wine fermentation. Eight micro-fermentation trials conducted in the Valtellina region (Northern Italy) during the 2009 vintage, were monitored by a FT-NIR and a FT-IR spectrometer and by an electronic nose and tongue. The spectroscopic technique was used to investigate molecular changes, while electronic nose and electronic tongue evaluated the evolution of the aroma and taste profile during the must-wine fermentation. Must-wine samples were also analysed by traditional chemical methods in order to determine sugars (glucose and fructose) consumption and alcohol (ethanol and glycerol) production. Principal Component Analysis was applied to spectral, electronic nose and electronic tongue data, as an exploratory tool, to uncover molecular, aroma and taste modifications during the fermentation process. Furthermore, the chemical data and the PC1 scores from spectral, electronic nose and electronic tongue data were modelled as a function of time to identify critical points during fermentation. The results showed that NIR and MIR

  1. Classification of human pathogen bacteria for early screening using electronic nose

    Science.gov (United States)

    Zulkifli, Syahida Amani; Mohamad, Che Wan Syarifah Robiah; Abdullah, Abu Hassan

    2017-10-01

    This paper present human pathogen bacteria for early screening using electronic nose. Electronic nose (E-nose) known as gas sensor array is a device that analyze the odor measurement give the fast response and less time consuming for clinical diagnosis. Many bacterial pathogens could lead to life threatening infections. Accurate and rapid diagnosis is crucial for the successful management of these infections disease. The conventional method need more time to detect the growth of bacterial. Alternatively, the bacteria are Pseudomonas aeruginosa and Shigella cultured on different media agar can be detected and classifies according to the volatile compound in shorter time using electronic nose (E-nose). Then, the data from electronic nose (E-nose) is processed using statistical method which is principal component analysis (PCA). The study shows the capability of electronic nose (E-nose) for early screening for bacterial infection in human stomach.

  2. Design of a portable electronic nose for real-fake detection of liquors

    Science.gov (United States)

    Qi, Pei-Feng; Zeng, Ming; Li, Zhi-Hua; Sun, Biao; Meng, Qing-Hao

    2017-09-01

    Portability is a major issue that influences the practical application of electronic noses (e-noses). For liquors detection, an e-nose must preprocess the liquid samples (e.g., using evaporation and thermal desorption), which makes the portable design even more difficult. To realize convenient and rapid detection of liquors, we designed a portable e-nose platform that consists of hardware and software systems. The hardware system contains an evaporation/sampling module, a reaction module, a control/data acquisition and analysis module, and a power module. The software system provides a user-friendly interface and can achieve automatic sampling and data processing. This e-nose platform has been applied to the real-fake recognition of Chinese liquors. Through parameter optimization of a one-class support vector machine classifier, the error rate of the negative samples is greatly reduced, and the overall recognition accuracy is improved. The results validated the feasibility of the designed portable e-nose platform.

  3. A Solid Trap and Thermal Desorption System with Application to a Medical Electronic Nose

    Directory of Open Access Journals (Sweden)

    Xuntao Xu

    2008-11-01

    Full Text Available In this paper, a solid trap/thermal desorption-based odorant gas condensation system has been designed and implemented for measuring low concentration odorant gas. The technique was successfully applied to a medical electronic nose system. The developed system consists of a flow control unit, a temperature control unit and a sorbent tube. The theoretical analysis and experimental results indicate that gas condensation, together with the medical electronic nose system can significantly reduce the detection limit of the nose system and increase the system’s ability to distinguish low concentration gas samples. In addition, the integrated system can remove the influence of background components and fluctuation of operational environment. Even with strong disturbances such as water vapour and ethanol gas, the developed system can classify the test samples accurately.

  4. Quality Evaluation of Agricultural Distillates Using an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Tomasz Dymerski

    2013-11-01

    Full Text Available The paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction of the agricultural distillate samples differing in quality was obtained by barbotage. Interpretation of the results involved three data analysis techniques: principal component analysis, single-linkage cluster analysis and cluster analysis with spheres method. The investigations prove the usefulness of the presented technique in the quality control of agricultural distillates. Optimum measurements conditions were also defined, including volumetric flow rate of carrier gas (15 L/h, thermostat temperature during the barbotage process (15 °C and time of sensor signal acquisition from the onset of the barbotage process (60 s.

  5. Quality evaluation of agricultural distillates using an electronic nose.

    Science.gov (United States)

    Dymerski, Tomasz; Gębicki, Jacek; Wardencki, Waldemar; Namieśnik, Jacek

    2013-11-25

    The paper presents the application of an electronic nose instrument to fast evaluation of agricultural distillates differing in quality. The investigations were carried out using a prototype of electronic nose equipped with a set of six semiconductor sensors by FIGARO Co., an electronic circuit converting signal into digital form and a set of thermostats able to provide gradient temperature characteristics to a gas mixture. A volatile fraction of the agricultural distillate samples differing in quality was obtained by barbotage. Interpretation of the results involved three data analysis techniques: principal component analysis, single-linkage cluster analysis and cluster analysis with spheres method. The investigations prove the usefulness of the presented technique in the quality control of agricultural distillates. Optimum measurements conditions were also defined, including volumetric flow rate of carrier gas (15 L/h), thermostat temperature during the barbotage process (15 °C) and time of sensor signal acquisition from the onset of the barbotage process (60 s).

  6. Meat quality assessment by electronic nose (machine olfaction technology).

    Science.gov (United States)

    Ghasemi-Varnamkhasti, Mahdi; Mohtasebi, Seyed Saeid; Siadat, Maryam; Balasubramanian, Sundar

    2009-01-01

    Over the last twenty years, newly developed chemical sensor systems (so called "electronic noses") have made odor analyses possible. These systems involve various types of electronic chemical gas sensors with partial specificity, as well as suitable statistical methods enabling the recognition of complex odors. As commercial instruments have become available, a substantial increase in research into the application of electronic noses in the evaluation of volatile compounds in food, cosmetic and other items of everyday life is observed. At present, the commercial gas sensor technologies comprise metal oxide semiconductors, metal oxide semiconductor field effect transistors, organic conducting polymers, and piezoelectric crystal sensors. Further sensors based on fibreoptic, electrochemical and bi-metal principles are still in the developmental stage. Statistical analysis techniques range from simple graphical evaluation to multivariate analysis such as artificial neural network and radial basis function. The introduction of electronic noses into the area of food is envisaged for quality control, process monitoring, freshness evaluation, shelf-life investigation and authenticity assessment. Considerable work has already been carried out on meat, grains, coffee, mushrooms, cheese, sugar, fish, beer and other beverages, as well as on the odor quality evaluation of food packaging material. This paper describes the applications of these systems for meat quality assessment, where fast detection methods are essential for appropriate product management. The results suggest the possibility of using this new technology in meat handling.

  7. Differentiation of closely related fungi by electronic nose analysis

    DEFF Research Database (Denmark)

    Karlshøj, Kristian; Nielsen, Per Væggemose; Larsen, Thomas Ostenfeld

    2007-01-01

    the electronic nose potentially responded to, volatile metabolites were collected, by diffusive sampling overnight onto tubes containing Tenax TA, between the 7th and 8th day of Incubation.Volatiles were analyzed by gas chromatography coupled to mass spectrometry and the results indicated that mail alcohols...... as well as the noacheese ociated P. expansum have been investigated by electronic nose, GC-MS, and LGMS analysis. The isolates were inoculated on yeast extract sucroseagar in 20-mL headspace flasks and electronicnose analysis was performed daily for a-74period. To assess which volatile metabolites...... by high pressure liquid chromatography, coupled-to a diode array detector and a time of flight mass spectrometer. Several mycotoxins were detected in samples from the specles P.nordicum, P.roqueforti, P.paneum, P.carneum, and P.expansum. Differentiation of closely related mycotoxin producing fungi...

  8. Development of an electronic nose for environmental odour monitoring.

    Science.gov (United States)

    Dentoni, Licinia; Capelli, Laura; Sironi, Selena; Del Rosso, Renato; Zanetti, Sonia; Della Torre, Matteo

    2012-10-25

    Exhaustive odour impact assessment should involve the evaluation of the impact of odours directly on citizens. For this purpose it might be useful to have an instrument capable of continuously monitoring ambient air quality, detecting the presence of odours and also recognizing their provenance. This paper discusses the laboratory and field tests conducted in order to evaluate the performance of a new electronic nose, specifically developed for monitoring environmental odours. The laboratory tests proved the instrument was able to discriminate between the different pure substances being tested, and to estimate the odour concentrations giving correlation indexes (R2) of 0.99 and errors below 15%. Finally, the experimental monitoring tests conducted in the field, allowed us to verify the effectiveness of this electronic nose for the continuous detection of odours in ambient air, proving its stability to variable atmospheric conditions and its capability to detect odour peaks.

  9. Acetic Acid Detection Threshold in Synthetic Wine Samples of a Portable Electronic Nose

    Directory of Open Access Journals (Sweden)

    Miguel Macías Macías

    2012-12-01

    Full Text Available Wine quality is related to its intrinsic visual, taste, or aroma characteristics and is reflected in the price paid for that wine. One of the most important wine faults is the excessive concentration of acetic acid which can cause a wine to take on vinegar aromas and reduce its varietal character. Thereby it is very important for the wine industry to have methods, like electronic noses, for real-time monitoring the excessive concentration of acetic acid in wines. However, aroma characterization of alcoholic beverages with sensor array electronic noses is a difficult challenge due to the masking effect of ethanol. In this work, in order to detect the presence of acetic acid in synthetic wine samples (aqueous ethanol solution at 10% v/v we use a detection unit which consists of a commercial electronic nose and a HSS32 auto sampler, in combination with a neural network classifier (MLP. To find the characteristic vector representative of the sample that we want to classify, first we select the sensors, and the section of the sensors response curves, where the probability of detecting the presence of acetic acid will be higher, and then we apply Principal Component Analysis (PCA such that each sensor response curve is represented by the coefficients of its first principal components. Results show that the PEN3 electronic nose is able to detect and discriminate wine samples doped with acetic acid in concentrations equal or greater than 2 g/L.

  10. Electronic Nose using Gas Chromatography Column and Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Hari Agus Sujono

    2011-08-01

    Full Text Available The conventional electronic nose usually consists of an array of dissimilar chemical sensors such as quartz crystal microbalance (QCM combined with pattern recognition algorithm such as Neural network. Because of parallel processing, the system needs a huge number of sensors and circuits which may emerge complexity and inter-channel crosstalk problems. In this research, a new type of odor identification which combines between gas chromatography (GC and electronic nose methods has been developed. The system consists of a GC column and a 10-MHz quartz crystal microbalance sensor producing a unique pattern for an odor in time domain. This method offers advantages of substantially reduced size, interferences and power consumption in comparison to existing odor identification system. Several odors of organic compounds were introduced to evaluate the selectivity of the system. Principle component analysis method was used to visualize the classification of each odor in two-dimensional space. This system could resolve common organic solvents, including molecules of different classes (aromatic from alcohols as well as those within a particular class (methanol from ethanol and also fuels (premium from pertamax. The neural network can be taught to recognize the odors tested in the experiment with identification rate of 85 %. It is therefore the system may take the place of human nose, especially for poisonous odor evaluations.

  11. Analog Multilayer Perceptron Circuit with On-chip Learning: Portable Electronic Nose

    Science.gov (United States)

    Pan, Chih-Heng; Tang, Kea-Tiong

    2011-09-01

    This article presents an analog multilayer perceptron (MLP) neural network circuit with on-chip back propagation learning. This low power and small area analog MLP circuit is proposed to implement as a classifier in an electronic nose (E-nose). Comparing with the E-nose using microprocessor or FPGA as a classifier, the E-nose applying analog circuit as a classifier can be faster and much smaller, demonstrate greater power efficiency and be capable of developing a portable E-nose [1]. The system contains four inputs, four hidden neurons, and only one output neuron; this simple structure allows the circuit to have a smaller area and less power consumption. The circuit is fabricated using TSMC 0.18 μm 1P6M CMOS process with 1.8 V supply voltage. The area of this chip is 1.353×1.353 mm2 and the power consumption is 0.54 mW. Post-layout simulations show that the proposed analog MLP circuit can be successively trained to identify three kinds of fruit odors.

  12. Prediction of egg freshness during storage using electronic nose.

    Science.gov (United States)

    Yimenu, Samuel M; Kim, J Y; Kim, B S

    2017-10-01

    The aim of the present study was to investigate the potential of a fast gas chromatography (GC) e-nose for freshness discrimination and for prediction of storage time as well as sensory and internal quality changes during storage of hen eggs. All samples were obtained from the same egg production farm and stored at 20 °C for 20 d. Egg sampling was conducted every 0, 3, 6, 9, 12, 16, and 20 d. During each sampling time, 4 egg cartons (each containing 10 eggs) were randomly selected: one carton for Haugh units, one carton for sensory evaluation and 2 cartons for the e-nose experiment. The e-nose study included 2 independent test sets; calibration (35 samples) and validation (28 samples). Every sampling time, 5 replicates were prepared from one egg carton for calibration samples and 4 replicates were prepared from the remaining egg carton for validation samples. Sensors (peaks) were selected prior to multivariate chemometric analysis; qualitative sensors for principal component analysis (PCA) and discriminant factor analysis (DFA) and quantitative sensors for partial least square (PLS) modeling. PCA and DFA confirmed the difference in volatile profiles of egg samples from 7 different storage times accounting for a total variance of 95.7% and 93.71%, respectively. Models for predicting storage time, Haugh units, odor score, and overall acceptability score from e-nose data were developed using calibration samples by PLS regression. The results showed that these quality indices were well predicted from the e- nose signals, with correlation coefficients of R2 = 0.9441, R2 = 0.9511, R2 = 0.9725, and R2 = 0.9530 and with training errors of 0.887, 1.24, 0.626, and 0.629, respectively. As a result of ANOVA, most of the PLS model results were not significantly (P > 0.05) different from the corresponding reference values. These results proved that the fast GC electronic nose has the potential to assess egg freshness and feasibility to predict multiple egg freshness indices

  13. Review of electronic-nose technologies and algorithms to detect hazardous chemicals in the environment

    Science.gov (United States)

    Alphus D. Wilson

    2012-01-01

    Novel mobile electronic-nose (e-nose) devices and algorithms capable of real-time detection of industrial and municipal pollutants, released from point-sources, recently have been developed by scientists worldwide that are useful for monitoring specific environmental-pollutant levels for enforcement and implementation of effective pollution-abatement programs. E-nose...

  14. Meat Quality Assessment by Electronic Nose (Machine Olfaction Technology

    Directory of Open Access Journals (Sweden)

    Sundar Balasubramanian

    2009-07-01

    Full Text Available Over the last twenty years, newly developed chemical sensor systems (so called “electronic noses” have made odor analyses possible. These systems involve various types of electronic chemical gas sensors with partial specificity, as well as suitable statistical methods enabling the recognition of complex odors. As commercial instruments have become available, a substantial increase in research into the application of electronic noses in the evaluation of volatile compounds in food, cosmetic and other items of everyday life is observed. At present, the commercial gas sensor technologies comprise metal oxide semiconductors, metal oxide semiconductor field effect transistors, organic conducting polymers, and piezoelectric crystal sensors. Further sensors based on fibreoptic, electrochemical and bi-metal principles are still in the developmental stage. Statistical analysis techniques range from simple graphical evaluation to multivariate analysis such as artificial neural network and radial basis function. The introduction of electronic noses into the area of food is envisaged for quality control, process monitoring, freshness evaluation, shelf-life investigation and authenticity assessment. Considerable work has already been carried out on meat, grains, coffee, mushrooms, cheese, sugar, fish, beer and other beverages, as well as on the odor quality evaluation of food packaging material. This paper describes the applications of these systems for meat quality assessment, where fast detection methods are essential for appropriate product management. The results suggest the possibility of using this new technology in meat handling.

  15. Screening Cereals Quality by Electronic Nose: the Example of Mycotoxins Naturally Contaminated Maize and Durum Wheat

    Science.gov (United States)

    Campagnoli, Anna; Dell'Orto, Vittorio; Savoini, Giovanni; Cheli, Federica

    2009-05-01

    Mycotoxins represent an heterogeneous group of toxic compounds from fungi metabolism. Due to the frequent occurrence of mycotoxins in cereals commodities the develop of cost/effective screening methods represent an important topic to ensure food and feed safety. In the presented study a commercial electronic nose constituted by ten MOS (Metal Oxide Sensors) was applied to verify the possibility of discriminating between mycotoxins contaminated and non-contaminated cereals. The described analytical approach was able to discriminate contaminated and non-contaminated samples both in the case of aflatoxins infected maize and deoxynivalenol infected durum wheat samples. In the case of maize data two sensors from the array revealed a partial relation with the level of aflatoxins. These results could be promising for a further improvement of electronic nose application in order to develop a semi-quantitative screening approach to mycotoxins contamination.

  16. Towards an electronic dog nose: surface plasmon resonance immunosensor for security and safety.

    Science.gov (United States)

    Onodera, Takeshi; Toko, Kiyoshi

    2014-09-05

    This review describes an "electronic dog nose" based on a surface plasmon resonance (SPR) sensor and an antigen-antibody interaction for security and safety. We have concentrated on developing appropriate sensor surfaces for the SPR sensor for practical use. The review covers different surface fabrications, which all include variations of a self-assembled monolayer containing oligo(ethylene glycol), dendrimer, and hydrophilic polymer. We have carried out detection of explosives using the sensor surfaces. For the SPR sensor to detect explosives, the vapor or particles of the target substances have to be dissolved in a liquid. Therefore, we also review the development of sampling processes for explosives, and a protocol for the measurement of explosives on the SPR sensor in the field. Additionally, sensing elements, which have the potential to be applied for the electronic dog nose, are described.

  17. Electronic Nose to Determine the Maturity Index of the Tree Tomato (Cyphomandra Betacea Sendt

    Directory of Open Access Journals (Sweden)

    Durán-Acevedo Cristhian Manuel

    2014-07-01

    Full Text Available This paper presents the development of an Electronic Nose for nondestructive monitoring of tree tomato ripening process (Cyphomandra Betacea Sendt. An array of 16 chemical gas sensors was arranged for the detection of three ripeness levels of tree types of tomato (green, ripe and overripe. A Probabilistic Neural Network (PNN as variable selection technique (Simulated Annealing was coupled to improve the result and the PCA (Principal Component Analysis technique was applied to discriminate each one of volatile compounds. A number of measures for physicochemical tests were analyzed with the goal of evaluating the physical, chemical and sensory properties (i.e, pH, acidity and Brix of the product, and the results of the Electronic Nose were compared. The olfactory system was able to classify the samples of tree tomato in three different stages with very high accuracy, to reach a success rate 99.886% in classification.

  18. Advances of electronic nose and its application in fresh foods: A review.

    Science.gov (United States)

    Shi, Hao; Zhang, Min; Adhikari, Benu

    2017-06-30

    The science and technology aspects of electronic nose (E-nose) has been developed rapidly in last decade (2006-2016). This paper reviews of the publications that that cover the developments in science and technological aspects of electronic nose together with its application in fresh foods. The first part of this review covers the sensing and pattern recognition system (PR) of E-nose. The second part covers the application of E-nose in classification, flavor detection, and evaluation of spoilage in fresh foods area. With more new sensor materials to be found and more combination between E-nose and other analysis technologies, the usages of E-nose in fresh foods will have wider prospects.

  19. Gas Classification Using Combined Features Based on a Discriminant Analysis for an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Sang-Il Choi

    2016-01-01

    Full Text Available This paper proposes a gas classification method for an electronic nose (e-nose system, for which combined features that have been configured through discriminant analysis are used. First, each global feature is extracted from the entire measurement section of the data samples, while the same process is applied to the local features of the section that corresponds to the stabilization, exposure, and purge stages. The discriminative information amounts in the individual features are then measured based on the discriminant analysis, and the combined features are subsequently composed by selecting the features that have a large amount of discriminative information. Regarding a variety of volatile organic compound data, the results of the experiment show that, in a noisy environment, the proposed method exhibits classification performance that is relatively excellent compared to the other feature types.

  20. Electronic Nose for Microbiological Quality Control of Food Products

    Directory of Open Access Journals (Sweden)

    M. Falasconi

    2012-01-01

    Full Text Available Electronic noses (ENs have recently emerged as valuable candidates in various areas of food quality control and traceability, including microbial contamination diagnosis. In this paper, the EN technology for microbiological screening of food products is reviewed. Four paradigmatic and diverse case studies are presented: (a Alicyclobacillus spp. spoilage of fruit juices, (b early detection of microbial contamination in processed tomatoes, (c screening of fungal and fumonisin contamination of maize grains, and (d fungal contamination on green coffee beans. Despite many successful results, the high intrinsic variability of food samples together with persisting limits of the sensor technology still impairs ENs trustful applications at the industrial scale. Both advantages and drawbacks of sensor technology in food quality control are discussed. Finally, recent trends and future directions are illustrated.

  1. Electronic Nose For Measuring Wine Evolution In Wine Cellars

    International Nuclear Information System (INIS)

    Lozano, J.; Santos, J. P.; Horrillo, M. C.; Cabellos, J. M.; Arroyo, T.

    2009-01-01

    An electronic nose installed in a wine cellar for measuring the wine evolution is presented in this paper. The system extract the aroma directly from the tanks where wine is stored and carry the volatile compounds to the sensors cell. A tin oxide multisensor, prepared with RF sputtering onto an alumina substrate and doped with chromium and indium, is used. The whole system is fully automated and controlled by computer and can be supervised by internet. Linear techniques like principal component analysis (PCA) and nonlinear ones like probabilistic neural networks (PNN) are used for pattern recognition. Results show that system can detect the evolution of two different wines along 9 months stored in tanks. This system could be trained to detect off-odours of wine and warn the wine expert to correct it as soon as possible, improving the final quality of wine.

  2. Electronic Nose Technology to Measure Soil Microbial Activity and Classify Soil Metabolic Status

    OpenAIRE

    Fabrizio De Cesare; Elena Di Mattia; Simone Pantalei; Emiliano Zampetti; Vittorio Vinciguerra; Antonella Macagnano

    2011-01-01

    The electronic nose (E-nose) is a sensing technology that has been widely used to monitor environments in the last decade. In the present study, the capability of an E-nose, in combination with biochemical and microbiological techniques, of both detecting the microbial activity and estimating the metabolic status of soil ecosystems, was tested by measuring on one side respiration, enzyme activities and growth of bacteria in natural but simplified soil ecosystems over 23 days of incubation thr...

  3. Determination of Ignitable Liquids in Fire Debris: Direct Analysis by Electronic Nose

    Directory of Open Access Journals (Sweden)

    Marta Ferreiro-González

    2016-05-01

    Full Text Available Arsonists usually use an accelerant in order to start or accelerate a fire. The most widely used analytical method to determine the presence of such accelerants consists of a pre-concentration step of the ignitable liquid residues followed by chromatographic analysis. A rapid analytical method based on headspace-mass spectrometry electronic nose (E-Nose has been developed for the analysis of Ignitable Liquid Residues (ILRs. The working conditions for the E-Nose analytical procedure were optimized by studying different fire debris samples. The optimized experimental variables were related to headspace generation, specifically, incubation temperature and incubation time. The optimal conditions were 115 °C and 10 min for these two parameters. Chemometric tools such as hierarchical cluster analysis (HCA and linear discriminant analysis (LDA were applied to the MS data (45–200 m/z to establish the most suitable spectroscopic signals for the discrimination of several ignitable liquids. The optimized method was applied to a set of fire debris samples. In order to simulate post-burn samples several ignitable liquids (gasoline, diesel, citronella, kerosene, paraffin were used to ignite different substrates (wood, cotton, cork, paper and paperboard. A full discrimination was obtained on using discriminant analysis. This method reported here can be considered as a green technique for fire debris analyses.

  4. Determination of Ignitable Liquids in Fire Debris: Direct Analysis by Electronic Nose

    Science.gov (United States)

    Ferreiro-González, Marta; Barbero, Gerardo F.; Palma, Miguel; Ayuso, Jesús; Álvarez, José A.; Barroso, Carmelo G.

    2016-01-01

    Arsonists usually use an accelerant in order to start or accelerate a fire. The most widely used analytical method to determine the presence of such accelerants consists of a pre-concentration step of the ignitable liquid residues followed by chromatographic analysis. A rapid analytical method based on headspace-mass spectrometry electronic nose (E-Nose) has been developed for the analysis of Ignitable Liquid Residues (ILRs). The working conditions for the E-Nose analytical procedure were optimized by studying different fire debris samples. The optimized experimental variables were related to headspace generation, specifically, incubation temperature and incubation time. The optimal conditions were 115 °C and 10 min for these two parameters. Chemometric tools such as hierarchical cluster analysis (HCA) and linear discriminant analysis (LDA) were applied to the MS data (45–200 m/z) to establish the most suitable spectroscopic signals for the discrimination of several ignitable liquids. The optimized method was applied to a set of fire debris samples. In order to simulate post-burn samples several ignitable liquids (gasoline, diesel, citronella, kerosene, paraffin) were used to ignite different substrates (wood, cotton, cork, paper and paperboard). A full discrimination was obtained on using discriminant analysis. This method reported here can be considered as a green technique for fire debris analyses. PMID:27187407

  5. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis

    NARCIS (Netherlands)

    de Vries, R.; Brinkman, P.; van der Schee, M. P.; Fens, N.; Dijkers, E.; Bootsma, S. K.; de Jongh, F. H. C.; Sterk, P. J.

    2015-01-01

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We

  6. Identification of insecticide residues with a conducting-polymer electronic nose

    Science.gov (United States)

    A.D. Wilson

    2014-01-01

    The identification of insecticide residues on crop foliage is needed to make periodic pest management decisions. Electronic-nose (e-nose) methods were developed and tested as a means of acquiring rapid identifications of insecticide residue types at relatively low cost by detection of headspace volatiles released from inert surfaces in vitro. Detection methods were...

  7. Identification and discrimination of herbicide residues using a conducting polymer electronic nose

    Science.gov (United States)

    Alphus Dan Wilson

    2016-01-01

    The identification of herbicide residues on crop foliage is necessary to make crop-management decisions for weed pest control and to monitor pesticide residue levels on food crops. Electronic-nose (e-nose) methods were tested as a cheaper, alternative means of discriminating between herbicide residue types (compared with conventional chromatography methods), by...

  8. Identification of the Rice Wines with Different Marked Ages by Electronic Nose Coupled with Smartphone and Cloud Storage Platform.

    Science.gov (United States)

    Wei, Zhebo; Xiao, Xize; Wang, Jun; Wang, Hui

    2017-10-31

    In this study, a portable electronic nose (E-nose) was self-developed to identify rice wines with different marked ages-all the operations of the E-nose were controlled by a special Smartphone Application. The sensor array of the E-nose was comprised of 12 MOS sensors and the obtained response values were transmitted to the Smartphone thorough a wireless communication module. Then, Aliyun worked as a cloud storage platform for the storage of responses and identification models. The measurement of the E-nose was composed of the taste information obtained phase (TIOP) and the aftertaste information obtained phase (AIOP). The area feature data obtained from the TIOP and the feature data obtained from the TIOP-AIOP were applied to identify rice wines by using pattern recognition methods. Principal component analysis (PCA), locally linear embedding (LLE) and linear discriminant analysis (LDA) were applied for the classification of those wine samples. LDA based on the area feature data obtained from the TIOP-AIOP proved a powerful tool and showed the best classification results. Partial least-squares regression (PLSR) and support vector machine (SVM) were applied for the predictions of marked ages and SVM (R² = 0.9942) worked much better than PLSR.

  9. Identification of the Rice Wines with Different Marked Ages by Electronic Nose Coupled with Smartphone and Cloud Storage Platform

    Directory of Open Access Journals (Sweden)

    Zhebo Wei

    2017-10-01

    Full Text Available In this study, a portable electronic nose (E-nose was self-developed to identify rice wines with different marked ages—all the operations of the E-nose were controlled by a special Smartphone Application. The sensor array of the E-nose was comprised of 12 MOS sensors and the obtained response values were transmitted to the Smartphone thorough a wireless communication module. Then, Aliyun worked as a cloud storage platform for the storage of responses and identification models. The measurement of the E-nose was composed of the taste information obtained phase (TIOP and the aftertaste information obtained phase (AIOP. The area feature data obtained from the TIOP and the feature data obtained from the TIOP-AIOP were applied to identify rice wines by using pattern recognition methods. Principal component analysis (PCA, locally linear embedding (LLE and linear discriminant analysis (LDA were applied for the classification of those wine samples. LDA based on the area feature data obtained from the TIOP-AIOP proved a powerful tool and showed the best classification results. Partial least-squares regression (PLSR and support vector machine (SVM were applied for the predictions of marked ages and SVM (R2 = 0.9942 worked much better than PLSR.

  10. A processing architecture for associative short-term memory in electronic noses

    Science.gov (United States)

    Pioggia, G.; Ferro, M.; Di Francesco, F.; DeRossi, D.

    2006-11-01

    Electronic nose (e-nose) architectures usually consist of several modules that process various tasks such as control, data acquisition, data filtering, feature selection and pattern analysis. Heterogeneous techniques derived from chemometrics, neural networks, and fuzzy rules used to implement such tasks may lead to issues concerning module interconnection and cooperation. Moreover, a new learning phase is mandatory once new measurements have been added to the dataset, thus causing changes in the previously derived model. Consequently, if a loss in the previous learning occurs (catastrophic interference), real-time applications of e-noses are limited. To overcome these problems this paper presents an architecture for dynamic and efficient management of multi-transducer data processing techniques and for saving an associative short-term memory of the previously learned model. The architecture implements an artificial model of a hippocampus-based working memory, enabling the system to be ready for real-time applications. Starting from the base models available in the architecture core, dedicated models for neurons, maps and connections were tailored to an artificial olfactory system devoted to analysing olive oil. In order to verify the ability of the processing architecture in associative and short-term memory, a paired-associate learning test was applied. The avoidance of catastrophic interference was observed.

  11. Calibration of an electronic nose for poultry farm

    Science.gov (United States)

    Abdullah, A. H.; Shukor, S. A.; Kamis, M. S.; Shakaff, A. Y. M.; Zakaria, A.; Rahim, N. A.; Mamduh, S. M.; Kamarudin, K.; Saad, F. S. A.; Masnan, M. J.; Mustafa, H.

    2017-03-01

    Malodour from the poultry farms could cause air pollution and therefore potentially dangerous to humans' and animals' health. This issue also poses sustainability risk to the poultry industries due to objections from local community. The aim of this paper is to develop and calibrate a cost effective and efficient electronic nose for poultry farm air monitoring. The instrument main components include sensor chamber, array of specific sensors, microcontroller, signal conditioning circuits and wireless sensor networks. The instrument was calibrated to allow classification of different concentrations of main volatile compounds in the poultry farm malodour. The outcome of the process will also confirm the device's reliability prior to being used for poultry farm malodour assessment. The Multivariate Analysis (HCA and KNN) and Artificial Neural Network (ANN) pattern recognition technique was used to process the acquired data. The results show that the instrument is able to calibrate the samples using ANN classification model with high accuracy. The finding verifies the instrument's performance to be used as an effective poultry farm malodour monitoring.

  12. A Novel Semi-Supervised Electronic Nose Learning Technique: M-Training

    Directory of Open Access Journals (Sweden)

    Pengfei Jia

    2016-03-01

    Full Text Available When an electronic nose (E-nose is used to distinguish different kinds of gases, the label information of the target gas could be lost due to some fault of the operators or some other reason, although this is not expected. Another fact is that the cost of getting the labeled samples is usually higher than for unlabeled ones. In most cases, the classification accuracy of an E-nose trained using labeled samples is higher than that of the E-nose trained by unlabeled ones, so gases without label information should not be used to train an E-nose, however, this wastes resources and can even delay the progress of research. In this work a novel multi-class semi-supervised learning technique called M-training is proposed to train E-noses with both labeled and unlabeled samples. We employ M-training to train the E-nose which is used to distinguish three indoor pollutant gases (benzene, toluene and formaldehyde. Data processing results prove that the classification accuracy of E-nose trained by semi-supervised techniques (tri-training and M-training is higher than that of an E-nose trained only with labeled samples, and the performance of M-training is better than that of tri-training because more base classifiers can be employed by M-training.

  13. Post-harvest Quality Evaluation of Grapes using Non-destructive Electronic Nose

    Directory of Open Access Journals (Sweden)

    RAJIN S. M. Ataul Karim

    2015-10-01

    Full Text Available Over the past decades, electronic nose has opened a variety of possibilities and is becoming one of the most important non-destructive odour inspection technologies in the food industry. The objective of this study is to determine the quality degradation of the fruit by monitoring the change in the volatile compound while kept in storage using a lab manufactured electronic nose. Here, grapes are chosen as the fruit sample for experiment. Principal component analysis (PCA is used to determine the ability of the electronic nose to distinguish the different quality of the fruit stored over an interval of time. The result shows that using PCA analysis, the electronic nose is able to identify a clear distinction between the aromas of grapes stored for different time intervals.

  14. Electronic nose breathprints are independent of acute changes in airway caliber in asthma

    NARCIS (Netherlands)

    Lazar, Zsofia; Fens, Niki; Van der Maten, Jan; van der Schee, Marc P.; Wagener, Ariane H.; de Nijs, Selma B.; Dijkers, Erica; Sterk, Peter J.

    2010-01-01

    Molecular profiling of exhaled volatile organic compounds (VOC) by electronic nose technology provides breathprints that discriminate between patients with different inflammatory airway diseases, such as asthma and COPD. However, it is unknown whether this is determined by differences in airway

  15. Electronic Nose Breathprints Are Independent of Acute Changes in Airway Caliber in Asthma

    NARCIS (Netherlands)

    Lazar, Z.; Fens, N.; Van der Maten, J.; van der Schee, M.P.; Wagener, A.H.; de Nijs, S.B.; Dijkers, E.; Sterk, P.J.

    2010-01-01

    Molecular profiling of exhaled volatile organic compounds (VOC) by electronic nose technology provides breathprints that discriminate between patients with different inflammatory airway diseases, such as asthma and COPD. However, it is unknown whether this is determined by differences in airway

  16. Quantification of Wine Mixtures with an Electronic Nose and a Human Panel

    Science.gov (United States)

    Aleixandre, Manuel; Cabellos, Juan M.; Arroyo, Teresa; Horrillo, M. C.

    2018-01-01

    In this work, an electronic nose and a human panel were used for the quantification of wines formed by binary mixtures of four white grape varieties and two varieties of red wines at different percentages (from 0 to 100% in 10% steps for the electronic nose and from 0 to 100% in 25% steps for the human panel). The wines were prepared using the traditional method with commercial yeasts. Both techniques were able to quantify the mixtures tested, but it is important to note that the technology of the electronic nose is faster, simpler, and more objective than the human panel. In addition, better results of quantification were also obtained using the electronic nose. PMID:29484296

  17. Discrimination of chicken seasonings and beef seasonings using electronic nose and sensory evaluation.

    Science.gov (United States)

    Tian, Huaixiang; Li, Fenghua; Qin, Lan; Yu, Haiyan; Ma, Xia

    2014-11-01

    This study examines the feasibility of electronic nose as a method to discriminate chicken and beef seasonings and to predict sensory attributes. Sensory evaluation showed that 8 chicken seasonings and 4 beef seasonings could be well discriminated and classified based on 8 sensory attributes. The sensory attributes including chicken/beef, gamey, garlic, spicy, onion, soy sauce, retention, and overall aroma intensity were generated by a trained evaluation panel. Principal component analysis (PCA), discriminant factor analysis (DFA), and cluster analysis (CA) combined with electronic nose were used to discriminate seasoning samples based on the difference of the sensor response signals of chicken and beef seasonings. The correlation between sensory attributes and electronic nose sensors signal was established using partial least squares regression (PLSR) method. The results showed that the seasoning samples were all correctly classified by the electronic nose combined with PCA, DFA, and CA. The electronic nose gave good prediction results for all the sensory attributes with correlation coefficient (r) higher than 0.8. The work indicated that electronic nose is an effective method for discriminating different seasonings and predicting sensory attributes. © 2014 Institute of Food Technologists®

  18. Is it possible to rapidly and noninvasively identify different plants from Asteraceae using electronic nose with multiple mathematical algorithms?

    Directory of Open Access Journals (Sweden)

    Hui-Qin Zou

    2015-12-01

    Full Text Available Many plants originating from the Asteraceae family are applied as herbal medicines and also beverage ingredients in Asian areas, particularly in China. However, they may be confused due to their similar odor, especially when ground into powder, losing their typical macroscopic characteristics. In this paper, 11 different multiple mathematical algorithms, which are commonly used in data processing, were utilized and compared to analyze the electronic nose (E-nose response signals of different plants from Asteraceae family. Results demonstrate that three-dimensional plot scatter figure of principal component analysis with less extracted components could offer the identification results more visually; simultaneously, all nine kinds of artificial neural network could give classification accuracies at 100%. This paper presents a rapid, accurate, and effective method to distinguish Asteraceae plants based on their response signals in E-nose. It also gives insights to further studies, such as to find unique sensors that are more sensitive and exclusive to volatile components in Chinese herbal medicines and to improve the identification ability of E-nose. Screening sensors made by other novel materials would be also an interesting way to improve identification capability of E-nose.

  19. Electronic Noses and Tongues: Applications for the Food and Pharmaceutical Industries

    Directory of Open Access Journals (Sweden)

    Sharon Dea

    2011-05-01

    Full Text Available The electronic nose (e-nose is designed to crudely mimic the mammalian nose in that most contain sensors that non-selectively interact with odor molecules to produce some sort of signal that is then sent to a computer that uses multivariate statistics to determine patterns in the data. This pattern recognition is used to determine that one sample is similar or different from another based on headspace volatiles. There are different types of e-nose sensors including organic polymers, metal oxides, quartz crystal microbalance and even gas-chromatography (GC or combined with mass spectroscopy (MS can be used in a non-selective manner using chemical mass or patterns from a short GC column as an e-nose or “Z” nose. The electronic tongue reacts similarly to non-volatile compounds in a liquid. This review will concentrate on applications of e-nose and e-tongue technology for edible products and pharmaceutical uses.

  20. Towards an Electronic Dog Nose: Surface Plasmon Resonance Immunosensor for Security and Safety

    Directory of Open Access Journals (Sweden)

    Takeshi Onodera

    2014-09-01

    Full Text Available This review describes an “electronic dog nose” based on a surface plasmon resonance (SPR sensor and an antigen–antibody interaction for security and safety. We have concentrated on developing appropriate sensor surfaces for the SPR sensor for practical use. The review covers different surface fabrications, which all include variations of a self-assembled monolayer containing oligo(ethylene glycol, dendrimer, and hydrophilic polymer. We have carried out detection of explosives using the sensor surfaces. For the SPR sensor to detect explosives, the vapor or particles of the target substances have to be dissolved in a liquid. Therefore, we also review the development of sampling processes for explosives, and a protocol for the measurement of explosives on the SPR sensor in the field. Additionally, sensing elements, which have the potential to be applied for the electronic dog nose, are described.

  1. Data Fusion of Electronic Nose and Electronic Tongue for Detection of Mixed Edible-Oil

    OpenAIRE

    Men, Hong; Chen, Donglin; Zhang, Xiaoting; Liu, Jingjing; Ning, Ke

    2014-01-01

    For the problem of the waste of the edible-oil in the food processing, on the premise of food security, they often need to add new edible-oil to the old frying oil which had been used in food processing to control the cost of the production. Due to the fact that the different additive proportion of the oil has different material and different volatile gases, we use fusion technology based on the electronic nose and electronic tongue to detect the blending ratio of the old frying oil and the n...

  2. Use of a MS-electronic nose for prediction of early fungal spoilage of bakery products.

    Science.gov (United States)

    Marín, S; Vinaixa, M; Brezmes, J; Llobet, E; Vilanova, X; Correig, X; Ramos, A J; Sanchis, V

    2007-02-28

    A MS-based electronic nose was used to detect fungal spoilage (measured as ergosterol concentration) in samples of bakery products. Bakery products were inoculated with different Eurotium, Aspergillus and Penicillium species, incubated in sealed vials and their headspace sampled after 2, 4 and 7 days. Once the headspace was sampled, ergosterol content was determined in each sample. Different electronic nose signals were recorded depending on incubation time. Both the e-nose signals and ergosterol levels were used to build models for prediction of ergosterol content using e-nose measurements. Accuracy on prediction of those models was between 87 and 96%, except for samples inoculated with Penicillium corylophilum where the best predictions only reached 46%.

  3. Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants

    Directory of Open Access Journals (Sweden)

    Bartosz Szulczyński

    2017-11-01

    Full Text Available This review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents commercially available sensors utilized in the electronic noses and characterized by the limit of quantification below 1 ppm v/v, which is close to the odour threshold of some odorants. Additionally, information about bioelectronic noses being a possible alternative to electronic noses and their principle of operation and application potential in the field of air evaluation with respect to detection of the odorants characterized by unpleasant odour was provided.

  4. Gestão de odores: fundamentos do Nariz Eletrônico Odor management: fundamentals of Electronic Nose

    Directory of Open Access Journals (Sweden)

    Henrique de Melo Lisboa

    2009-03-01

    Full Text Available Narizes Eletrônicos têm sido desenvolvidos para detecção automática e classificação de odores, vapores e gases. São instrumentos capazes de medir a concentração ou intensidade odorante de modo similar a um olfatômetro, mas sem as limitações inerentes ao uso de painéis humanos, o que é altamente desejável. Um Nariz Eletrônico é geralmente composto por um sistema de sensores químicos e um sistema eletrônico associado à inteligência artificial para reconhecimento. Têm sido aplicados em muitas áreas, tais como análise de alimentos, controles ambientais e diagnósticos médicos. Do ponto de vista ambiental, sistemas de Narizes Eletrônicos vêm sendo usados para monitorar a qualidade do ar, detectar fontes e quantificar emissões odorantes. Este artigo pretende apresentar os fundamentos dos Narizes Eletrônicos.Electronic noses have been developed for automatic detection and classification of odors, vapors and gases. They are instruments capable to identify odors as the human nose does, and measure the odor concentration or intensity according to similar metrics as an olfactometer, but without the inherent limitations of human panels. An Electronic Nose is generally composed of a matrix of chemical sensors and computer based system for odor recognition and classification. It has been applied in many areas, such as food quality analysis, explosives detection, environmental monitoring and medical diagnosis. In the ambient environment, systems of Electronic Noses have been used to monitor the quality of air and to detect and quantify odor sources and emissions. This article intends to present the fundamentals and main characteristics of Electronic Noses.

  5. Development of a Portable Electronic Nose System for the Detection and Classification of Fruity Odors

    Directory of Open Access Journals (Sweden)

    Kea-Tiong Tang

    2010-10-01

    Full Text Available In this study, we have developed a prototype of a portable electronic nose (E-Nose comprising a sensor array of eight commercially available sensors, a data acquisition interface PCB, and a microprocessor. Verification software was developed to verify system functions. Experimental results indicate that the proposed system prototype is able to identify the fragrance of three fruits, namely lemon, banana, and litchi.

  6. On-line monitoring of food fermentation processes using electronic noses and electronic tongues: A review

    Energy Technology Data Exchange (ETDEWEB)

    Peris, Miguel, E-mail: mperist@qim.upv.es [Departamento de Química, Universidad Politécnica de Valencia, 46071 Valencia (Spain); Escuder-Gilabert, Laura [Departamento de Química Analítica, Universitat de Valencia, C/ Vicente Andrés Estellés s/n, E-46100 Burjasot, Valencia (Spain)

    2013-12-04

    Graphical abstract: -- Highlights: •This review paper deals with the applications of electronic noses and electronic tongues to the monitoring of fermentation processes. •Positive and negative aspects of the different approaches reviewed are analyzed. •Current and future endeavors in this field are also commented. -- Abstract: Fermentation processes are often sensitive to even slight changes of conditions that may result in unacceptable end-product quality. Thus, close follow-up of this type of processes is critical for detecting unfavorable deviations as early as possible in order to save downtime, materials and resources. Nevertheless the use of traditional analytical techniques is often hindered by the need for expensive instrumentation and experienced operators and complex sample preparation. In this sense, one of the most promising ways of developing rapid and relatively inexpensive methods for quality control in fermentation processes is the use of chemical multisensor systems. In this work we present an overview of the most important contributions dealing with the monitoring of fermentation processes using electronic noses and electronic tongues. After a brief description of the fundamentals of both types of devices, the different approaches are critically commented, their strengths and weaknesses being highlighted. Finally, future trends in this field are also mentioned in the last section of the article.

  7. On-line monitoring of food fermentation processes using electronic noses and electronic tongues: A review

    International Nuclear Information System (INIS)

    Peris, Miguel; Escuder-Gilabert, Laura

    2013-01-01

    Graphical abstract: -- Highlights: •This review paper deals with the applications of electronic noses and electronic tongues to the monitoring of fermentation processes. •Positive and negative aspects of the different approaches reviewed are analyzed. •Current and future endeavors in this field are also commented. -- Abstract: Fermentation processes are often sensitive to even slight changes of conditions that may result in unacceptable end-product quality. Thus, close follow-up of this type of processes is critical for detecting unfavorable deviations as early as possible in order to save downtime, materials and resources. Nevertheless the use of traditional analytical techniques is often hindered by the need for expensive instrumentation and experienced operators and complex sample preparation. In this sense, one of the most promising ways of developing rapid and relatively inexpensive methods for quality control in fermentation processes is the use of chemical multisensor systems. In this work we present an overview of the most important contributions dealing with the monitoring of fermentation processes using electronic noses and electronic tongues. After a brief description of the fundamentals of both types of devices, the different approaches are critically commented, their strengths and weaknesses being highlighted. Finally, future trends in this field are also mentioned in the last section of the article

  8. Electronic Nose Testing Procedure for the Definition of Minimum Performance Requirements for Environmental Odor Monitoring

    Directory of Open Access Journals (Sweden)

    Lidia Eusebio

    2016-09-01

    Full Text Available Despite initial enthusiasm towards electronic noses and their possible application in different fields, and quite a lot of promising results, several criticalities emerge from most published research studies, and, as a matter of fact, the diffusion of electronic noses in real-life applications is still very limited. In general, a first step towards large-scale-diffusion of an analysis method, is standardization. The aim of this paper is describing the experimental procedure adopted in order to evaluate electronic nose performances, with the final purpose of establishing minimum performance requirements, which is considered to be a first crucial step towards standardization of the specific case of electronic nose application for environmental odor monitoring at receptors. Based on the experimental results of the performance testing of a commercialized electronic nose type with respect to three criteria (i.e., response invariability to variable atmospheric conditions, instrumental detection limit, and odor classification accuracy, it was possible to hypothesize a logic that could be adopted for the definition of minimum performance requirements, according to the idea that these are technologically achievable.

  9. Recent advances in electronic nose techniques for monitoring of fermentation process.

    Science.gov (United States)

    Jiang, Hui; Zhang, Hang; Chen, Quansheng; Mei, Congli; Liu, Guohai

    2015-12-01

    Microbial fermentation process is often sensitive to even slight changes of conditions that may result in unacceptable end-product quality. Thus, the monitoring of the process is critical for discovering unfavorable deviations as early as possible and taking the appropriate measures. However, the use of traditional analytical techniques is often time-consuming and labor-intensive. In this sense, the most effective way of developing rapid, accurate and relatively economical method for quality assurance in microbial fermentation process is the use of novel chemical sensor systems. Electronic nose techniques have particular advantages in non-invasive monitoring of microbial fermentation process. Therefore, in this review, we present an overview of the most important contributions dealing with the quality control in microbial fermentation process using the electronic nose techniques. After a brief description of the fundamentals of the sensor techniques, some examples of potential applications of electronic nose techniques monitoring are provided, including the implementation of control strategies and the combination with other monitoring tools (i.e. sensor fusion). Finally, on the basis of the review, the electronic nose techniques are critically commented, and its strengths and weaknesses being highlighted. In addition, on the basis of the observed trends, we also propose the technical challenges and future outlook for the electronic nose techniques.

  10. A novel method for qualitative analysis of edible oil oxidation using an electronic nose.

    Science.gov (United States)

    Xu, Lirong; Yu, Xiuzhu; Liu, Lei; Zhang, Rui

    2016-07-01

    An electronic nose (E-nose) was used for rapid assessment of the degree of oxidation in edible oils. Peroxide and acid values of edible oil samples were analyzed using data obtained by the American Oil Chemists' Society (AOCS) Official Method for reference. Qualitative discrimination between non-oxidized and oxidized oils was conducted using the E-nose technique developed in combination with cluster analysis (CA), principal component analysis (PCA), and linear discriminant analysis (LDA). The results from CA, PCA and LDA indicated that the E-nose technique could be used for differentiation of non-oxidized and oxidized oils. LDA produced slightly better results than CA and PCA. The proposed approach can be used as an alternative to AOCS Official Method as an innovative tool for rapid detection of edible oil oxidation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    Science.gov (United States)

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Quality evaluation of agricultural distillates using different types of electronic noses

    Science.gov (United States)

    Dymerski, Tomasz; Gebicki, Jacek; Namieśnik, Jacek

    2014-08-01

    The paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type- HERACLES II. The prototype was equipped with TGS type semiconductor sensors. HERACLES II included two chromatographic columns with different polarity of stationary phase and two FID detectors. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process, whereas HERACLES II analysed the headspace fraction. Classification of the samples into three quality classes was performed using: quadratic discriminant function (QDA), supported with cross-validation method. Over 95% correct classification of the agricultural distillates into particular quality classes was observed for the analyses with HERACLES II. The prototype of electronic nose provided correct classification at the level of 70%.

  13. Bacterial Infection Potato Tuber Soft Rot Disease Detection Based on Electronic Nose

    Directory of Open Access Journals (Sweden)

    Chang Zhiyong

    2017-11-01

    Full Text Available Soft rot is a severe bacterial disease of potatoes, and soft rot infection can cause significant economic losses during the storage period of potatoes. In this study, potato soft rot was selected as the research object, and a type of potato tuber soft rot disease early detection method based on the electronic nose technology was proposed. An optimized bionic electronic nose gas chamber and a scientific and reasonable sampling device were designed to detect a change in volatile substances of the infected soft rot disease of potato tuber. The infection of soft rot disease in potato tuber samples was detected and identified by using the RBF NN algorithm and SVM algorithm. The results revealed that the proposed bionic electronic nose system can be utilized for early detection of potato tuber soft rot disease. Through comparison and analysis, the recognition rate using the SVM algorithm reached up to 89.7%, and the results were superior to the RBF NN algorithm.

  14. Potential application of electronic nose in processed animal proteins (PAP detection in feedstuffs

    Directory of Open Access Journals (Sweden)

    Dell'Orto V.

    2004-01-01

    Full Text Available Electronic nose and olfactometry techniques represent a modern analytical approach in food industry since they could potentially improve quality and safety of food processing. The aim of this study was to evaluate possible application of electronic nose in PA P detection and recognition in feed. For this purpose 6 reference feedstuffs (CRA-W / UE STRAT F E E D Project were used. The basis of the test samples was a compound feed for bovine fortified with processed animal proteins ( PAP consisting of meat and bone meal (MBM and/or fish meal at different concentrations. Each feed sample was tested in glass vials and the odour profile was determined by the ten MOS (metal oxide semi-conductor sensors of the electronic nose. Ten different descriptors, representing each ten sensors of electronic nose, were used to characterise the odour of each sample. In the present study, electronic nose was able to discriminate the blank sample from all other samples containing PA P ( M B M , fish meal or both. Samples containing either 0.5% of MBM or 5% of fish meal were identified, while samples containing a high fish meal content (5% associated with a low MBM content (0.5% were not discriminated from samples containing solely fish meal at that same high level (5%. This latter indicates that probably the high fish meal level, in samples containing both MBM and fish meal, tended to mask MBM odour. It was also evident that two odour descriptors were enough to explain 72.12% of total variability in odour pattern. In view of these results, it could be suggested that electronic nose and olfactometry techniques can provide an interesting approach for screening raw materials in feed industry, even though further studies using a wider set of samples are needed.

  15. Continuous monitoring of odours from a composting plant using electronic noses.

    Science.gov (United States)

    Sironi, Selena; Capelli, Laura; Céntola, Paolo; Del Rosso, Renato; Il Grande, Massimiliano

    2007-01-01

    The odour impact of a composting plant situated in an urbanized area was evaluated by continuously monitoring the ambient air close to the plant during a period of about 4 days using two electronic noses. One electronic nose was installed in a nearby house, and the other one inside the perimeter of the composting plant in order to compare the response of both instruments. The results of the monitoring are represented by tables that report the olfactory class and the odour concentration value attributed to the analyzed air for each of the 370 measurements carried out during the monitoring period. The electronic nose installed at the house detected the presence of odours coming from the composting plant for about 7.8% of the monitoring total duration. Of the odour detections, 86% (25 of 29 measurements) were classified as belonging to the olfactory class corresponding to the open air storage of the waste screening overflows heaps, which was therefore identified to be the major odour source of the monitored composting plant. In correspondence of the measurements during which the electronic nose inside the house detected the presence of odours from the composting plant, the olfactory classes recognized by both instruments coincide. Moreover, the electronic nose at the house detected the presence of odours from the composting plant at issue in correspondence of each odour perception of the house occupants. The results of the study show the possibility of using an electronic nose for environmental odours monitoring, which enables the classification of the quality of the air and to quantify the olfactory nuisance from an industrial source in terms of duration and odour concentration.

  16. Detection and Classification of Human Body Odor Using an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Teerakiat Kerdcharoen

    2009-09-01

    Full Text Available An electronic nose (E-nose has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  17. Detection and classification of human body odor using an electronic nose.

    Science.gov (United States)

    Wongchoosuk, Chatchawal; Lutz, Mario; Kerdcharoen, Teerakiat

    2009-01-01

    An electronic nose (E-nose) has been designed and equipped with software that can detect and classify human armpit body odor. An array of metal oxide sensors was used for detecting volatile organic compounds. The measurement circuit employs a voltage divider resistor to measure the sensitivity of each sensor. This E-nose was controlled by in-house developed software through a portable USB data acquisition card with a principle component analysis (PCA) algorithm implemented for pattern recognition and classification. Because gas sensor sensitivity in the detection of armpit odor samples is affected by humidity, we propose a new method and algorithms combining hardware/software for the correction of the humidity noise. After the humidity correction, the E-nose showed the capability of detecting human body odor and distinguishing the body odors from two persons in a relative manner. The E-nose is still able to recognize people, even after application of deodorant. In conclusion, this is the first report of the application of an E-nose for armpit odor recognition.

  18. Diverse Applications of Electronic-Nose Technologies in Agriculture and Forestry

    Science.gov (United States)

    Wilson, Alphus D.

    2013-01-01

    Electronic-nose (e-nose) instruments, derived from numerous types of aroma-sensor technologies, have been developed for a diversity of applications in the broad fields of agriculture and forestry. Recent advances in e-nose technologies within the plant sciences, including improvements in gas-sensor designs, innovations in data analysis and pattern-recognition algorithms, and progress in material science and systems integration methods, have led to significant benefits to both industries. Electronic noses have been used in a variety of commercial agricultural-related industries, including the agricultural sectors of agronomy, biochemical processing, botany, cell culture, plant cultivar selections, environmental monitoring, horticulture, pesticide detection, plant physiology and pathology. Applications in forestry include uses in chemotaxonomy, log tracking, wood and paper processing, forest management, forest health protection, and waste management. These aroma-detection applications have improved plant-based product attributes, quality, uniformity, and consistency in ways that have increased the efficiency and effectiveness of production and manufacturing processes. This paper provides a comprehensive review and summary of a broad range of electronic-nose technologies and applications, developed specifically for the agriculture and forestry industries over the past thirty years, which have offered solutions that have greatly improved worldwide agricultural and agroforestry production systems. PMID:23396191

  19. Diverse applications of electronic-nose technologies in agriculture and forestry.

    Science.gov (United States)

    Wilson, Alphus D

    2013-02-08

    Electronic-nose (e-nose) instruments, derived from numerous types of aroma-sensor technologies, have been developed for a diversity of applications in the broad fields of agriculture and forestry. Recent advances in e-nose technologies within the plant sciences, including improvements in gas-sensor designs, innovations in data analysis and pattern-recognition algorithms, and progress in material science and systems integration methods, have led to significant benefits to both industries. Electronic noses have been used in a variety of commercial agricultural-related industries, including the agricultural sectors of agronomy, biochemical processing, botany, cell culture, plant cultivar selections, environmental monitoring, horticulture, pesticide detection, plant physiology and pathology. Applications in forestry include uses in chemotaxonomy, log tracking, wood and paper processing, forest management, forest health protection, and waste management. These aroma-detection applications have improved plant-based product attributes, quality, uniformity, and consistency in ways that have increased the efficiency and effectiveness of production and manufacturing processes. This paper provides a comprehensive review and summary of a broad range of electronic-nose technologies and applications, developed specifically for the agriculture and forestry industries over the past thirty years, which have offered solutions that have greatly improved worldwide agricultural and agroforestry production systems.

  20. An improved approach to identify irradiated spices using electronic nose, FTIR, and EPR spectroscopy.

    Science.gov (United States)

    Sanyal, Bhaskar; Ahn, Jae-Jun; Maeng, Jeong-Hwan; Kyung, Hyun-Kyu; Lim, Ha-Kyeong; Sharma, Arun; Kwon, Joong-Ho

    2014-09-01

    Changes in cumin and chili powder from India resulting from electron-beam irradiation were investigated using 3 analytical methods: electronic nose (E-nose), Fourier transform infrared (FTIR) spectroscopy, and electron paramagnetic resonance (EPR) spectroscopy. The spices had been exposed to 6 to 14 kGy doses recommended for microbial decontamination. E-nose measured a clear difference in flavor patterns of the irradiated spices in comparison with the nonirradiated samples. Principal component analysis further showed a dose-dependent variation. FTIR spectra of the samples showed strong absorption bands at 3425, 3007 to 2854, and 1746 cm(-1). However, both nonirradiated and irradiated spice samples had comparable patterns without any noteworthy changes in functional groups. EPR spectroscopy of the irradiated samples showed a radiation-specific triplet signal at g = 2.006 with a hyper-fine coupling constant of 3 mT confirming the results obtained with the E-nose technique. Thus, E-nose was found to be a potential tool to identify irradiated spices. © 2014 Institute of Food Technologists®

  1. Odor Profile of Different Varieties of Extra-Virgin Olive Oil During Deep Frying Using an Electronic Nose and SPME-GC-FID

    Science.gov (United States)

    Messina, Valeria; Biolatto, Andrea; Sancho, Ana; Descalzo, Adriana; Grigioni, Gabriela; de Reca, Noemí Walsöe

    2011-09-01

    The aim of the performed work was to evaluate with an electronic nose changes in odor profile of Arauco and Arbequina varieties of extra-virgin olive oil during deep-frying. Changes in odor were analyzed using an electronic nose composed of 16 sensors. Volatile compounds were analyzed by SPME-GC-FID. Principal Component Analysis was applied for electronic results. Arauco variety showed the highest response for sensors. Statistical analysis for volatile compounds indicated a significant (P<0.001) interaction between variety and time of frying processes. Arauco variety showed the highest production of volatile compounds at 60 min of deep frying. The two varieties presented distinct patterns of volatile products, being clearly identified with the electronic nose.

  2. Application of fuzzy logic to determine the odour intensity of model gas mixtures using electronic nose

    Science.gov (United States)

    Szulczyński, Bartosz; Gębicki, Jacek; Namieśnik, Jacek

    2018-01-01

    The paper presents the possibility of application of fuzzy logic to determine the odour intensity of model, ternary gas mixtures (α-pinene, toluene and triethylamine) using electronic nose prototype. The results obtained using fuzzy logic algorithms were compared with the values obtained using multiple linear regression (MLR) model and sensory analysis. As the results of the studies, it was found the electronic nose prototype along with the fuzzy logic pattern recognition system can be successfully used to estimate the odour intensity of tested gas mixtures. The correctness of the results obtained using fuzzy logic was equal to 68%.

  3. Monitoring storage time and quality attribute of egg based on electronic nose

    International Nuclear Information System (INIS)

    Wang Yongwei; Jun Wang; Bo Zhou; Qiujun Lu

    2009-01-01

    The objective of this study was to investigate the potential of an electronic nose (E-nose) technique for monitoring egg storage time and quality attributes. An electronic nose was used to distinguish eggs under cool and room-temperature storage by means of principal component analysis (PCA), linear discriminant analysis (LDA), BP neural network (BPNN) and the combination of a genetic algorithm and BP neural network (GANN). Results showed that the E-nose could distinguish eggs of different storage time under cool and room-temperature storage by LDA, PCA, BPNN and GANN; better prediction values were obtained by GANN than by BPNN. Relationships were established between the E-nose signal and egg quality indices (Haugh unit and yolk factor) by quadratic polynomial step regression (QPSR). The prediction models for Haugh unit and yolk factor indicated a good prediction performance. The Haugh unit model had a standard error of prediction of 3.74 and correlation coefficient 0.91; the yolk factor model had a 0.02 SEP and 0.93 correlation coefficient between predicted and measured values respectively.

  4. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD

    NARCIS (Netherlands)

    Dragonieri, Silvano; Annema, Jouke T.; Schot, Robert; van der Schee, Marc P. C.; Spanevello, Antonio; Carratú, Pierluigi; Resta, Onofrio; Rabe, Klaus F.; Sterk, Peter J.

    2009-01-01

    Background: Exhaled breath contains thousands of gaseous volatile organic compounds (VOCs) that may be used as non-invasive markers of lung disease. The electronic nose analyzes VOCs by composite nano-sensor arrays with learning algorithms. It has been shown that an electronic nose can distinguish

  5. Thermo-oxidation in Arauco and Arbequina Extra-virgin Olive Oil. Changes in Odour using and Electronic Nose and SPME-GC-FID

    Directory of Open Access Journals (Sweden)

    Valeria Messina

    2010-06-01

    Full Text Available Changes in odour of Arauco and Arbequina extra-virgin olive oil were monitored during frying by electronic nose and solid-phase microextraction–gas chromatography methodologies. Electronic nose data and volatile compounds were analyzed at intervals of 60 min (t60 during 180 min of frying (t180. Principal components analysis applied to electronic nose data showed one component, PC1 which accounted 96.3 % of the total odour variation. SnO2 sensors had a positive correlation with PC1. Arauco variety corresponding to frying t120 and t180 had the highest positive correlation with PC1. Analysis of variance results for volatile compounds showed an increase on production for: 3-methyl butanal, n-pentanal, n-hexanal, n-heptanal and n-nonanal at 60 min of frying for both varieties.

  6. Research on Electronic-nose Application Based on Wireless Sensor Networks

    International Nuclear Information System (INIS)

    Zhao, A; Wang, L; Yao, C H

    2006-01-01

    The paper proposed a structure of Wireless Sensor Networks based Electronic-nose system to monitors air quality in the building. In the study, the authors researched a data processing algorithm: fuzzy neural network based on RBF(Radial Basis Function) network model, to quantitatively analyze the gas ingredient and put forward a routing protocol for the system

  7. Electronic-nose technology using sputum samples in diagnosis of patients with tuberculosis

    NARCIS (Netherlands)

    Kolk, A.; Hoelscher, M.; Maboko, L.; Jung, J.; Kuijper, S.; Cauchi, M.; Bessant, C.; van Beers, S.; Dutta, R.; Gibson, T.; Reither, K.

    2010-01-01

    We investigated the potential of two different electronic noses (EN; code named "Rob" and "Walter") to differentiate between sputum headspace samples from tuberculosis (TB) patients and non-TB patients. Only samples from Ziehl-Neelsen stain (ZN)- and Mycobacterium tuberculosis culture-positive

  8. Monitoring of biological odour filtration in closed environments with olfactometry and an electronic nose

    NARCIS (Netherlands)

    Willers, H.C.; Gijsel, de P.; Ogink, N.W.M.; Amico, D' A.; Martinelli, E.; Natale, Di C.; Ras, van N.; Waarde, van der J.

    2004-01-01

    Air treatment with a compact biological membrane filter, and air quality monitoring with an electronic nose were tested in the laboratory on air from a cage containing six mice. Additional analyses of air to and from the filter were performed using olfactometry and ammonia and hydrogen sulphide gas

  9. Detection of Off-Flavor in Catfish Using a Conducting Polymer Electronic-Nose Technology

    Science.gov (United States)

    Wilson, Alphus D.; Oberle, Charisse S.; Oberle, Daniel F.

    2013-01-01

    The Aromascan A32S conducting polymer electronic nose was evaluated for the capability of detecting the presence of off-flavor malodorous compounds in catfish meat fillets to assess meat quality for potential merchantability. Sensor array outputs indicated that the aroma profiles of good-flavor (on-flavor) and off-flavor fillets were strongly different as confirmed by a Principal Component Analysis (PCA) and a Quality Factor value (QF > 7.9) indicating a significant difference at (P 90%) and with relatively low rates (≤5%) of unknown or indecisive determinations in three trials. This A32S e-nose instrument also was capable of detecting the incidence of mild off-flavor in fillets at levels lower than the threshold of human olfactory detection. Potential applications of e-nose technologies for pre- and post-harvest management of production and meat-quality downgrade problems associated with catfish off-flavor are discussed. PMID:24287526

  10. A Novel Wearable Electronic Nose for Healthcare Based on Flexible Printed Chemical Sensor Array

    Directory of Open Access Journals (Sweden)

    Panida Lorwongtragool

    2014-10-01

    Full Text Available A novel wearable electronic nose for armpit odor analysis is proposed by using a low-cost chemical sensor array integrated in a ZigBee wireless communication system. We report the development of a carbon nanotubes (CNTs/polymer sensor array based on inkjet printing technology. With this technique both composite-like layer and actual composite film of CNTs/polymer were prepared as sensing layers for the chemical sensor array. The sensor array can response to a variety of complex odors and is installed in a prototype of wearable e-nose for monitoring the axillary odor released from human body. The wearable e-nose allows the classification of different armpit odors and the amount of the volatiles released as a function of level of skin hygiene upon different activities.

  11. Application Of Electronic Nose And Ion Mobility Spectrometer To Quality Control Of Spice Mixtures

    International Nuclear Information System (INIS)

    Banach, U.; Tiebe, C.; Huebert, Th.

    2009-01-01

    The aim of the paper is to demonstrate the application of electronic nose (e-nose) and ion mobility spectrometry (IMS) to quality control and to find out product adulteration of spice mixtures. Therefore the gaseous head space phase of four different spice mixtures (spices for sausages and saveloy) was differed from original composition and product adulteration. In this set of experiments metal-oxide type e-nose (KAMINA-type) has been used, and characteristic patterns of data corresponding to various complex odors of the four different spice mixtures were generated. Simultaneously an ion mobility spectrometer was coupled also to an emission chamber for the detection of gaseous components of spice mixtures. The two main methods that have been used show a clear discrimination between the original spice mixtures and product adulteration could be distinguished from original spice mixtures.

  12. Application of Electronic Noses for Disease Diagnosis and Food Spoilage Detection

    OpenAIRE

    Casalinuovo, Ida A.; Di Pierro, Donato; Coletta, Massimiliano; Di Francesco, Paolo

    2006-01-01

    Over the last twenty years, newly developed chemical sensor systems (so-called “electronic noses”) have odour analyses made possible. This paper describes the applications of these systems for microbial detection in different fields such as medicine and the food industry, where fast detection methods are essential for appropriate management of health care. Several groups have employed different electronic noses for classification and quantification of bacteria and fungi to obtain accurate med...

  13. Detecting aroma changes of local flavored green tea (Camellia sinensis) using electronic nose

    Science.gov (United States)

    Ralisnawati, D.; Sukartiko, A. C.; Suryandono, A.; Triyana, K.

    2018-03-01

    Indonesia is currently the sixth largest tea producer in the world. However, consumption of the product in the country was considered low. Besides tea, the country also has various local flavor ingredients that are potential to be developed. The addition of local flavored ingredients such as ginger, lemon grass, and lime leaves on green tea products is gaining acceptance from consumers and producers. The aroma of local flavored green tea was suspected to changes during storage, while its sensory testing has some limitations. Therefore, the study aimed to detect aroma changes of local flavors added in green tea using electronic nose (e-nose), an instrument developed to mimic the function of the human nose. The test was performed on a four-gram sample. The data was collected with 120 seconds of sensing time and 60 seconds of blowing time. Principal Component Analysis (PCA) was used to find out the aroma changes of local flavored green tea during storage. We observed that electronic nose could detect aroma changes of ginger flavored green tea from day 0 to day 6 with variance percentage 99.6%. Variance proportion of aroma changes of lemon grass flavored green tea from day 0 to day 6 was 99.3%. Variance proportion of aroma changes of lime leaves flavored green tea from day 0 to day 6 was 99.4%.

  14. Training and Validating a Portable Electronic Nose for Lung Cancer Screening.

    Science.gov (United States)

    van de Goor, Rens; van Hooren, Michel; Dingemans, Anne-Marie; Kremer, Bernd; Kross, Kenneth

    2018-05-01

    Profiling volatile organic compounds in exhaled breath enables the diagnosis of several types of cancer. In this study we investigated whether a portable point-of-care version of an electronic nose (e-nose) (Aeonose, [eNose Company, Zutphen, the Netherlands]) is able to discriminate between patients with lung cancer and healthy controls on the basis of their volatile organic compound pattern. In this study, we used five e-nose devices to collect breath samples from patients with lung cancer and healthy controls. A total of 60 patients with lung cancer and 107 controls exhaled through an e-nose for 5 minutes. Patients were assigned either to a training group for building an artificial neural network model or to a blinded control group for validating this model. For differentiating patients with lung cancer from healthy controls, the results showed a diagnostic accuracy of 83% with a sensitivity of 83%, specificity of 84%, and area under the curve of 0.84. Results for the blinded group showed comparable results, with a sensitivity of 88%, specificity of 86%, and diagnostic accuracy of 86%. This feasibility study showed that this portable e-nose can properly differentiate between patients with lung cancer and healthy controls. This result could have important implications for future lung cancer screening. Further studies with larger cohorts, including also more participants with early-stage tumors, should be performed to increase the robustness of this noninvasive diagnostic tool and to determine its added value in the diagnostic chain for lung cancer. Copyright © 2018 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  15. Using the Electronic Nose to Identify Airway Infection during COPD Exacerbations.

    Directory of Open Access Journals (Sweden)

    Hanaa Shafiek

    Full Text Available The electronic nose (e-nose detects volatile organic compounds (VOCs in exhaled air. We hypothesized that the exhaled VOCs print is different in stable vs. exacerbated patients with chronic obstructive pulmonary disease (COPD, particularly if the latter is associated with airway bacterial infection, and that the e-nose can distinguish them.Smell-prints of the bacteria most commonly involved in exacerbations of COPD (ECOPD were identified in vitro. Subsequently, we tested our hypothesis in 93 patients with ECOPD, 19 of them with pneumonia, 50 with stable COPD and 30 healthy controls in a cross-sectional case-controlled study. Secondly, ECOPD patients were re-studied after 2 months if clinically stable. Exhaled air was collected within a Tedlar bag and processed by a Cynarose 320 e-nose. Breath-prints were analyzed by Linear Discriminant Analysis (LDA with "One Out" technique and Sensor logic Relations (SLR. Sputum samples were collected for culture.ECOPD with evidence of infection were significantly distinguishable from non-infected ECOPD (p = 0.018, with better accuracy when ECOPD was associated to pneumonia. The same patients with ECOPD were significantly distinguishable from stable COPD during follow-up (p = 0.018, unless the patient was colonized. Additionally, breath-prints from COPD patients were significantly distinguished from healthy controls. Various bacteria species were identified in culture but the e-nose was unable to identify accurately the bacteria smell-print in infected patients.E-nose can identify ECOPD, especially if associated with airway bacterial infection or pneumonia.

  16. Electronic-nose applications in forensic science and for analysis of volatile biomarkers in the human breath

    Science.gov (United States)

    AD Wilson

    2014-01-01

    The application of electronic-nose (E-nose) technologies in forensic science is a recent new development following a long history of progress in the development of diverse applications in the related biomedical and pharmaceutical fields. Data from forensic analyses must satisfy the needs and requirements of both the scientific and legal communities. The type of data...

  17. Advances in electronic-nose technologies for the detection of volatile biomarker metabolites in the human breath

    Science.gov (United States)

    Alphus D. Wilson

    2015-01-01

    Recent advancements in the use of electronic-nose (e-nose) devices to analyze human breath profiles for the presence of specific volatile metabolites, known as biomarkers or chemical bio-indicators of specific human diseases, metabolic disorders and the overall health status of individuals, are providing the potential for new noninvasive tools and techniques useful to...

  18. Integration of electronic nose technology with spirometry: validation of a new approach for exhaled breath analysis.

    Science.gov (United States)

    de Vries, R; Brinkman, P; van der Schee, M P; Fens, N; Dijkers, E; Bootsma, S K; de Jongh, F H C; Sterk, P J

    2015-10-15

    New 'omics'-technologies have the potential to better define airway disease in terms of pathophysiological and clinical phenotyping. The integration of electronic nose (eNose) technology with existing diagnostic tests, such as routine spirometry, can bring this technology to 'point-of-care'. We aimed to determine and optimize the technical performance and diagnostic accuracy of exhaled breath analysis linked to routine spirometry. Exhaled breath was collected in triplicate in healthy subjects by an eNose (SpiroNose) based on five identical metal oxide semiconductor sensor arrays (three arrays monitoring exhaled breath and two reference arrays monitoring ambient air) at the rear end of a pneumotachograph. First, the influence of flow, volume, humidity, temperature, environment, etc, was assessed. Secondly, a two-centre case-control study was performed using diagnostic and monitoring visits in day-to-day clinical care in patients with a (differential) diagnosis of asthma, chronic obstructive pulmonary disease (COPD) or lung cancer. Breathprint analysis involved signal processing, environment correction based on alveolar gradients and statistics based on principal component (PC) analysis, followed by discriminant analysis (Matlab2014/SPSS20). Expiratory flow showed a significant linear correlation with raw sensor deflections (R(2)  =  0.84) in 60 healthy subjects (age 43  ±  11 years). No correlation was found between sensor readings and exhaled volume, humidity and temperature. Exhaled data after environment correction were highly reproducible for each sensor array (Cohen's Kappa 0.81-0.94). Thirty-seven asthmatics (41  ±  14.2 years), 31 COPD patients (66  ±  8.4 years), 31 lung cancer patients (63  ±  10.8 years) and 45 healthy controls (41  ±  12.5 years) entered the cross-sectional study. SpiroNose could adequately distinguish between controls, asthma, COPD and lung cancer patients with cross-validation values

  19. Performance Comparison of Fuzzy ARTMAP and LDA in Qualitative Classification of Iranian Rosa damascena Essential Oils by an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Abbas Gorji-Chakespari

    2016-05-01

    Full Text Available Quality control of essential oils is an important topic in industrial processing of medicinal and aromatic plants. In this paper, the performance of Fuzzy Adaptive Resonant Theory Map (ARTMAP and linear discriminant analysis (LDA algorithms are compared in the specific task of quality classification of Rosa damascene essential oil samples (one of the most famous and valuable essential oils in the world using an electronic nose (EN system based on seven metal oxide semiconductor (MOS sensors. First, with the aid of a GC-MS analysis, samples of Rosa damascene essential oils were classified into three different categories (low, middle, and high quality, classes C1, C2, and C3, respectively based on the total percent of the most crucial qualitative compounds. An ad-hoc electronic nose (EN system was implemented to sense the samples and acquire signals. Forty-nine features were extracted from the EN sensor matrix (seven parameters to describe each sensor curve response. The extracted features were ordered in relevance by the intra/inter variance criterion (Vr, also known as the Fisher discriminant. A leave-one-out cross validation technique was implemented for estimating the classification accuracy reached by both algorithms. Success rates were calculated using 10, 20, 30, and the entire selected features from the response of the sensor array. The results revealed a maximum classification accuracy of 99% when applying the Fuzzy ARTMAP algorithm and 82% for LDA, using the first 10 features in both cases. Further classification results explained that sub-optimal performance is likely to occur when all the response features are applied. It was found that an electronic nose system employing a Fuzzy ARTMAP classifier could become an accurate, easy, and inexpensive alternative tool for qualitative control in the production of Rosa damascene essential oil.

  20. Detection of Off-Flavor in Catfish Using a Conducting Polymer Electronic-Nose Technology

    Directory of Open Access Journals (Sweden)

    Alphus D. Wilson

    2013-11-01

    Full Text Available The Aromascan A32S conducting polymer electronic nose was evaluated for the capability of detecting the presence of off-flavor malodorous compounds in catfish meat fillets to assess meat quality for potential merchantability. Sensor array outputs indicated that the aroma profiles of good-flavor (on-flavor and off-flavor fillets were strongly different as confirmed by a Principal Component Analysis (PCA and a Quality Factor value (QF > 7.9 indicating a significant difference at (P < 0.05. The A32S e-nose effectively discriminated between good-flavor and off-flavor catfish at high levels of accuracy (>90% and with relatively low rates (≤5% of unknown or indecisive determinations in three trials. This A32S e-nose instrument also was capable of detecting the incidence of mild off-flavor in fillets at levels lower than the threshold of human olfactory detection. Potential applications of e-nose technologies for pre- and post-harvest management of production and meat-quality downgrade problems associated with catfish off-flavor are discussed.

  1. Valid Probabilistic Predictions for Ginseng with Venn Machines Using Electronic Nose

    Directory of Open Access Journals (Sweden)

    You Wang

    2016-07-01

    Full Text Available In the application of electronic noses (E-noses, probabilistic prediction is a good way to estimate how confident we are about our prediction. In this work, a homemade E-nose system embedded with 16 metal-oxide semi-conductive gas sensors was used to discriminate nine kinds of ginsengs of different species or production places. A flexible machine learning framework, Venn machine (VM was introduced to make probabilistic predictions for each prediction. Three Venn predictors were developed based on three classical probabilistic prediction methods (Platt’s method, Softmax regression and Naive Bayes. Three Venn predictors and three classical probabilistic prediction methods were compared in aspect of classification rate and especially the validity of estimated probability. A best classification rate of 88.57% was achieved with Platt’s method in offline mode, and the classification rate of VM-SVM (Venn machine based on Support Vector Machine was 86.35%, just 2.22% lower. The validity of Venn predictors performed better than that of corresponding classical probabilistic prediction methods. The validity of VM-SVM was superior to the other methods. The results demonstrated that Venn machine is a flexible tool to make precise and valid probabilistic prediction in the application of E-nose, and VM-SVM achieved the best performance for the probabilistic prediction of ginseng samples.

  2. Pattern Classification Using an Olfactory Model with PCA Feature Selection in Electronic Noses: Study and Application

    Directory of Open Access Journals (Sweden)

    Junbao Zheng

    2012-03-01

    Full Text Available Biologically-inspired models and algorithms are considered as promising sensor array signal processing methods for electronic noses. Feature selection is one of the most important issues for developing robust pattern recognition models in machine learning. This paper describes an investigation into the classification performance of a bionic olfactory model with the increase of the dimensions of input feature vector (outer factor as well as its parallel channels (inner factor. The principal component analysis technique was applied for feature selection and dimension reduction. Two data sets of three classes of wine derived from different cultivars and five classes of green tea derived from five different provinces of China were used for experiments. In the former case the results showed that the average correct classification rate increased as more principal components were put in to feature vector. In the latter case the results showed that sufficient parallel channels should be reserved in the model to avoid pattern space crowding. We concluded that 6~8 channels of the model with principal component feature vector values of at least 90% cumulative variance is adequate for a classification task of 3~5 pattern classes considering the trade-off between time consumption and classification rate.

  3. Quantitative analysis of different volatile organic compounds using an improved electronic nose

    International Nuclear Information System (INIS)

    Gao, Daqi; Ji, Jiuming; Gong, Jiayu; Cai, Chaoqian

    2012-01-01

    This paper sets up an improved electronic nose with an automatic sampling mode, large volumetric vapors and constant temperature for headspace vapors and gas sensor array. In order to facilitate the fast recovery and good repeatability of gas sensors, the steps taken include (A) short-time contact with odors measured; (B) long-time purification using environmental air; (C) exact calibration using clean air before sampling. We employ multiple single-output perceptrons to discriminate and quantify multiple kinds of odors. This task is first regarded as multiple two-class discrimination problems and then multiple quantification problems, and accomplished by multiple single-output perceptrons followed by multiple single-output perceptrons. The experimental results for measuring and quantifying 12 kinds of volatile organic compounds with changing concentrations show that the type of electronic nose with a hierarchical perceptron model has a simple structure, easy operation, good repeatability and good discrimination and quantification performance. (paper)

  4. Quantitative analysis of different volatile organic compounds using an improved electronic nose

    Science.gov (United States)

    Gao, Daqi; Ji, Jiuming; Gong, Jiayu; Cai, Chaoqian

    2012-10-01

    This paper sets up an improved electronic nose with an automatic sampling mode, large volumetric vapors and constant temperature for headspace vapors and gas sensor array. In order to facilitate the fast recovery and good repeatability of gas sensors, the steps taken include (A) short-time contact with odors measured; (B) long-time purification using environmental air; (C) exact calibration using clean air before sampling. We employ multiple single-output perceptrons to discriminate and quantify multiple kinds of odors. This task is first regarded as multiple two-class discrimination problems and then multiple quantification problems, and accomplished by multiple single-output perceptrons followed by multiple single-output perceptrons. The experimental results for measuring and quantifying 12 kinds of volatile organic compounds with changing concentrations show that the type of electronic nose with a hierarchical perceptron model has a simple structure, easy operation, good repeatability and good discrimination and quantification performance.

  5. Electronic Nose Characterization of the Quality Parameters of Freeze-Dried Bacteria

    Science.gov (United States)

    Capuano, R.; Santonico, M.; Martinelli, E.; Paolesse, R.; Passot, S.; Fonseca, F.; Cenard, S.; Trelea, C.; Di Natale, C.

    2011-09-01

    Freeze-drying is the method of choice for preserving heat sensitive biological products such as microorganisms. The development of a fast analytical method for evaluating the properties of the dehydrated bacteria is then necessary for a proper utilization of the product in several food processes. In this paper, dried bacteria headspace is analyzed by a GC-MS and an electronic nose. Results indicate that headspace contains enough information to assess the products quality.

  6. Electronic Nose Breathprints Are Independent of Acute Changes in Airway Caliber in Asthma

    Directory of Open Access Journals (Sweden)

    Jan van der Maten

    2010-10-01

    Full Text Available Molecular profiling of exhaled volatile organic compounds (VOC by electronic nose technology provides breathprints that discriminate between patients with different inflammatory airway diseases, such as asthma and COPD. However, it is unknown whether this is determined by differences in airway caliber. We hypothesized that breathprints obtained by electronic nose are independent of acute changes in airway caliber in asthma. Ten patients with stable asthma underwent methacholine provocation (Visit 1 and sham challenge with isotonic saline (Visit 2. At Visit 1, exhaled air was repetitively collected pre-challenge, after reaching the provocative concentration (PC20 causing 20% fall in forced expiratory volume in 1 second (FEV1 and after subsequent salbutamol inhalation. At Visit 2, breath was collected pre-challenge, post-saline and post-salbutamol. At each occasion, an expiratory vital capacity was collected after 5 min of tidal breathing through an inspiratory VOC-filter in a Tedlar bag and sampled by electronic nose (Cyranose 320. Breathprints were analyzed with principal component analysis and individual factors were compared with mixed model analysis followed by pairwise comparisons. Inhalation of methacholine led to a 30.8 ± 3.3% fall in FEV1 and was followed by a significant change in breathprint (p = 0.04. Saline inhalation did not induce a significant change in FEV1, but altered the breathprint (p = 0.01. However, the breathprint obtained after the methacholine provocation was not significantly different from that after saline challenge (p = 0.27. The molecular profile of exhaled air in patients with asthma is altered by nebulized aerosols, but is not affected by acute changes in airway caliber. Our data demonstrate that breathprints by electronic nose are not confounded by the level of airway obstruction.

  7. Chemical Selectivity and Sensitivity of a 16-Channel Electronic Nose for Trace Vapour Detection

    Directory of Open Access Journals (Sweden)

    Drago Strle

    2017-12-01

    Full Text Available Good chemical selectivity of sensors for detecting vapour traces of targeted molecules is vital to reliable detection systems for explosives and other harmful materials. We present the design, construction and measurements of the electronic response of a 16 channel electronic nose based on 16 differential microcapacitors, which were surface-functionalized by different silanes. The e-nose detects less than 1 molecule of TNT out of 10+12 N2 molecules in a carrier gas in 1 s. Differently silanized sensors give different responses to different molecules. Electronic responses are presented for TNT, RDX, DNT, H2S, HCN, FeS, NH3, propane, methanol, acetone, ethanol, methane, toluene and water. We consider the number density of these molecules and find that silane surfaces show extreme affinity for attracting molecules of TNT, DNT and RDX. The probability to bind these molecules and form a surface-adsorbate is typically 10+7 times larger than the probability to bind water molecules, for example. We present a matrix of responses of differently functionalized microcapacitors and we propose that chemical selectivity of multichannel e-nose could be enhanced by using artificial intelligence deep learning methods.

  8. Sensory methods and electronic nose as innovative tools for the evaluation of the aroma transfer properties of food plastic bags.

    Science.gov (United States)

    Torri, Luisa; Piochi, Maria

    2016-07-01

    Despite the key role of the sensory quality for food acceptance, the aroma transfer properties of food packaging materials have not yet been studied using sensory approaches. This research investigated the suitability of sensory and electronic nose methods to evaluate the aroma transfer properties of plastic materials that come in contact with food. Four (W, X, Y, and Z) commercial freezer bags (polyethylene) for domestic uses were compared. The degree of the aroma transfer through the materials was estimated as the sensory contamination of an odor absorber food (bread) by an odor releaser food (onion), separated by the bags and stored under frozen conditions. Bread samples were analyzed by means of an electronic nose, and 42 assessors used three different sensory methods (triangle, scoring, and partial sorted Napping tests). From the triangle test, none of the plastic bags acted as a complete aroma barrier, showing a sensory contamination of bread stored in all four materials. Partial sorting Napping results clearly described the sensory contamination of bread as "onion flavor", due to the aroma transfer from the odor releaser food to the odor absorber food through the plastic bag. Scoring tests showed significant (pbags, revealing the highest aroma permeation for W (3.1±0.1), the lowest aroma transfer for X and Y (2.0±0.1), and intermediate aroma transfer properties for Z (2.6±0.1). Electronic nose data were in good agreement with the sensory responses, and a high correlation with the scoring data was observed (R 2 =0.988). The presented approaches had suitable results to provide meaningful information on the aroma transfer properties of freezer plastic bags, and could advantageously be applied in the future for analyzing other finished food containers (e.g. plastic trays, boxes, etc.) or packaging materials of a different nature (multilayer plastic films, biodegradable materials, composites, etc.). Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Pressure-driven fast reaction and recovery of peptide receptor for an electronic nose application

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Yong Kyoung [Department of Electrical Engineering, Kwangwoon University, Seoul 139-701 (Korea, Republic of); Center for Biomicrosystems, Korea Institute of Science and Technology, Seoul 136-791 (Korea, Republic of); Lee, Sang-Myung [Department of Chemical Engineering, Kangwon National University, Kangwon-do 200-701 (Korea, Republic of); Chae, Myung-Sic; Yoon Kang, Ji; Song Kim, Tae; Seon Hwang, Kyo, E-mail: kshwang@kist.re.kr, E-mail: jhlee@kw.ac.kr [Center for Biomicrosystems, Korea Institute of Science and Technology, Seoul 136-791 (Korea, Republic of); Hoon Lee, Jeong, E-mail: kshwang@kist.re.kr, E-mail: jhlee@kw.ac.kr [Department of Electrical Engineering, Kwangwoon University, Seoul 139-701 (Korea, Republic of)

    2014-02-24

    Combining a highly sensitive sensor platform with highly selective recognition elements is essential for micro/nanotechnology-based electronic nose applications. Particularly, the regeneration sensor surface and its conditions are key issues for practical e-nose applications. We propose a highly sensitive piezoelectric-driven microcantilever array chip with highly selective peptide receptors. By utilizing the peptide receptor, which was discovered by a phase display screening process, we immobilized a dinitrotoluene (DNT) specific peptide as well as a DNT nonspecific peptide on the surface of the cantilever array. The delivery of DNT gas via pressure-driven flow led to a greater instant response of ∼30 Hz, compared to diffusion only (∼15 Hz for 15 h). Using a simple pressure-driven air flow of ∼50 sccm, we confirmed that a ratio of ∼70% of the specific-bounded sites from DNT gas molecules could be regenerated, showing re-usability of the peptide receptor in on-site monitoring for electronic nose applications.

  10. Validation of honey-bee smelling profile by using a commercial electronic nose

    Directory of Open Access Journals (Sweden)

    Ana R. Correa

    2017-09-01

    Full Text Available Honey is a natural sweetener and its quality labels are associated to its botanical or geographical origin, which is being established by palynological and sensorial analysis. The use of fast and non-invasive techniques such as an electronic nose can become an alternative for honey classification. In this study, the operational parameters of a commercial electronic nose were validated to determine the honey odor profile. A central composite design with five factors, three levels and 28 assays was used, varying sample amounts (1, 2 and 3 g, incubation temperature (30, 40 and 50 °C, incubation time 30 min, gas flow (50, 150 and 250 mL/min and injection time (100, 200 and 300 s. The commercial nose had ten sensors. Repeatability was evaluated with a coefficient of variation of 10 %. The response surface methodology was used and the optimal operating conditions were: 3 g of sample, incubation at 50 °C for 17 min, gas flow of 100 mL/min and sampling time of 150 s. Finally, these parameters were used to analyze 19 samples of honey, which were classified according to their odor profiles, showing that it can be a useful tool to classify honey.

  11. The prediction of food additives in the fruit juice based on electronic nose with chemometrics.

    Science.gov (United States)

    Qiu, Shanshan; Wang, Jun

    2017-09-01

    Food additives are added to products to enhance their taste, and preserve flavor or appearance. While their use should be restricted to achieve a technological benefit, the contents of food additives should be also strictly controlled. In this study, E-nose was applied as an alternative to traditional monitoring technologies for determining two food additives, namely benzoic acid and chitosan. For quantitative monitoring, support vector machine (SVM), random forest (RF), extreme learning machine (ELM) and partial least squares regression (PLSR) were applied to establish regression models between E-nose signals and the amount of food additives in fruit juices. The monitoring models based on ELM and RF reached higher correlation coefficients (R 2 s) and lower root mean square errors (RMSEs) than models based on PLSR and SVM. This work indicates that E-nose combined with RF or ELM can be a cost-effective, easy-to-build and rapid detection system for food additive monitoring. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Quality-grade evaluation of petroleum waxes using an electronic nose with a TGS gas sensor array

    International Nuclear Information System (INIS)

    Wang, Ji; Gao, Daqi; Wang, Zejian

    2015-01-01

    In this paper, the potential of an improved electronic nose to discriminate the quality of petroleum waxes based on their volatile profile was analyzed. Two datasets at 25 and 50 °C were collected from an experiment in order to compare influence by temperature. More fine-grained levels were further labeled for classification to meet various purposes. As petroleum waxes with lower odor levels are more difficult and important to identify than those with higher odor levels, we focus on the discrimination task for low-level ones. Principal component analysis was used for dimensionality reduction and data visualization. k-nearest neighbors, support vector machine, and multilayer perceptron were employed to classify among different qualities of petroleum waxes. The leave-one-out cross-validation method was employed due to the small sample sizes. Results showed good performance on both datasets, and at a temperature of 50 °C all pattern recognition methods showed improved classification rates. The improved electronic nose can potentially be applied to discriminate the quality of petroleum wax. (paper)

  13. Calibration transfer between electronic nose systems for rapid In situ measurement of pulp and paper industry emissions

    International Nuclear Information System (INIS)

    Deshmukh, Sharvari; Kamde, Kalyani; Jana, Arun; Korde, Sanjivani; Bandyopadhyay, Rajib; Sankar, Ravi; Bhattacharyya, Nabarun; Pandey, R.A.

    2014-01-01

    Highlights: • E-nose developed for obnoxious emissions measurement at pulp and paper industrial site. • ANN model developed for prediction of (CH 3 ) 2 S, (CH 3 ) 2 S 2 , CH 3 SH and H 2 S concentration. • Calibration transfer methodology developed for transfer between two e-nose instruments. • Box–Behnken design and robust regression used for calibration transfer. • Results show effective transfer of training model from one e-nose system to other. - Abstract: Electronic nose systems when deployed in network mesh can effectively provide a low budget and onsite solution for the industrial obnoxious gaseous measurement. For accurate and identical prediction capability by all the electronic nose systems, a reliable calibration transfer model needs to be implemented in order to overcome the inherent sensor array variability. In this work, robust regression (RR) is used for calibration transfer between two electronic nose systems using a Box–Behnken (BB) design. Out of the two electronic nose systems, one was trained using industrial gas samples by four artificial neural network models, for the measurement of obnoxious odours emitted from pulp and paper industries. The emissions constitute mainly of hydrogen sulphide (H 2 S), methyl mercaptan (MM), dimethyl sulphide (DMS) and dimethyl disulphide (DMDS) in different proportions. A Box–Behnken design consisting of 27 experiment sets based on synthetic gas combinations of H 2 S, MM, DMS and DMDS, were conducted for calibration transfer between two identical electronic nose systems. Identical sensors on both the systems were mapped and the prediction models developed using ANN were then transferred to the second system using BB–RR methodology. The results showed successful transmission of prediction models developed for one system to other system, with the mean absolute error between the actual and predicted concentration of analytes in mg L −1 after calibration transfer (on second system) being 0.076, 0

  14. A False Alarm Reduction Method for a Gas Sensor Based Electronic Nose

    Directory of Open Access Journals (Sweden)

    Mohammad Mizanur Rahman

    2017-09-01

    Full Text Available Electronic noses (E-Noses are becoming popular for food and fruit quality assessment due to their robustness and repeated usability without fatigue, unlike human experts. An E-Nose equipped with classification algorithms and having open ended classification boundaries such as the k-nearest neighbor (k-NN, support vector machine (SVM, and multilayer perceptron neural network (MLPNN, are found to suffer from false classification errors of irrelevant odor data. To reduce false classification and misclassification errors, and to improve correct rejection performance; algorithms with a hyperspheric boundary, such as a radial basis function neural network (RBFNN and generalized regression neural network (GRNN with a Gaussian activation function in the hidden layer should be used. The simulation results presented in this paper show that GRNN has more correct classification efficiency and false alarm reduction capability compared to RBFNN. As the design of a GRNN and RBFNN is complex and expensive due to large numbers of neuron requirements, a simple hyperspheric classification method based on minimum, maximum, and mean (MMM values of each class of the training dataset was presented. The MMM algorithm was simple and found to be fast and efficient in correctly classifying data of training classes, and correctly rejecting data of extraneous odors, and thereby reduced false alarms.

  15. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    Science.gov (United States)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  16. Identification of Four Wood Species by an Electronic Nose and by LIBS

    Directory of Open Access Journals (Sweden)

    Juliana R. Cordeiro

    2012-01-01

    Full Text Available This paper presents two complementary methods capable of identifying four wood species (Cedrela fissilis, Ocotea porosa, Hymenolobium petraeum, and Aspidosperma subincanum both by their volatile organic compounds and by the presence of 10 chemical elements: Al, B, Ca, Mg, Zn, Cu, Mn, Fe, Na, and Si. The volatile compounds were detected by an electronic nose formed by an array of three different conductive polymer gas sensors. The elemental determination was made by laser-induced breakdown spectrometry (LIBS. The emissions measured were treated by principal component analysis (PCA. Leave-one-out analysis showed a rate of hits of 100%.

  17. Identification Of Geographical Origin Of Coffee Before And After Roasting By Electronic Noses

    Science.gov (United States)

    Sberveglieri, V.; Concina, I.; Falasconi, M.; Ongo, E.; Pulvirenti, A.; Fava, P.

    2011-09-01

    Geographical origin traceability of food is a relevant issue for both producers' business protection and customers' rights safeguard. Differentiation of coffees on the basis of geographical origin is still a challenging issue, though possible by means of chemical techniques [1]. Between the most widely consumed beverage, coffee is a valuable one, with an aroma constituted by hundreds of volatiles [2]. Since the final global volatile composition is also determined by the cultivation climatic conditions, Electronic Noses (ENs) could be interesting candidates for distinguishing the geographical provenience by exploiting differences in chemical volatile profile. The present investigation is directed toward the characterization of green and roasted coffees samples according to their geographical origin.

  18. Polymer-carbon black composite sensors in an electronic nose for air-quality monitoring

    Science.gov (United States)

    Ryan, M. A.; Shevade, A. V.; Zhou, H.; Homer, M. L.

    2004-01-01

    An electronic nose that uses an array of 32 polymer-carbon black composite sensors has been developed, trained, and tested. By selecting a variety of chemical functionalities in the polymers used to make sensors, it is possible to construct an array capable of identifying and quantifying a broad range of target compounds, such as alcohols and aromatics, and distinguishing isomers and enantiomers (mirror-image isomers). A model of the interaction between target molecules and the polymer-carbon black composite sensors is under development to aid in selecting the array members and to enable identification of compounds with responses not stored in the analysis library.

  19. Application of the Electronic Nose Technique to Differentiation between Model Mixtures with COPD Markers

    Directory of Open Access Journals (Sweden)

    Jacek Namieśnik

    2013-04-01

    Full Text Available The paper presents the potential of an electronic nose technique in the field of fast diagnostics of patients suspected of Chronic Obstructive Pulmonary Disease (COPD. The investigations were performed using a simple electronic nose prototype equipped with a set of six semiconductor sensors manufactured by FIGARO Co. They were aimed at verification of a possibility of differentiation between model reference mixtures with potential COPD markers (N,N-dimethylformamide and N,N-dimethylacetamide. These mixtures contained volatile organic compounds (VOCs such as acetone, isoprene, carbon disulphide, propan-2-ol, formamide, benzene, toluene, acetonitrile, acetic acid, dimethyl ether, dimethyl sulphide, acrolein, furan, propanol and pyridine, recognized as the components of exhaled air. The model reference mixtures were prepared at three concentration levels—10 ppb, 25 ppb, 50 ppb v/v—of each component, except for the COPD markers. Concentration of the COPD markers in the mixtures was from 0 ppb to 100 ppb v/v. Interpretation of the obtained data employed principal component analysis (PCA. The investigations revealed the usefulness of the electronic device only in the case when the concentration of the COPD markers was twice as high as the concentration of the remaining components of the mixture and for a limited number of basic mixture components.

  20. Volatile aroma components and MS-based electronic nose profiles of dogfruit (Pithecellobium jiringa and stink bean (Parkia speciosa

    Directory of Open Access Journals (Sweden)

    Yonathan Asikin

    2018-01-01

    Full Text Available Dogfruit (Pithecellobium jiringa and stink bean (Parkia speciosa are two typical smelly legumes from Southeast Asia that are widely used in the cuisines of this region. Headspace/gas chromatography/flame ionization detection analysis and mass spectrometry (MS-based electronic nose techniques were applied to monitor ripening changes in the volatile flavor profiles of dogfruit and stink bean. Compositional analysis showed that the ripening process greatly influenced the composition and content of the volatile aroma profiles of these two smelly food materials, particularly their alcohol, aldehyde, and sulfur components. The quantity of predominant hexanal in stink bean significantly declined (P < 0.05 during the ripening process, whereas the major volatile components of dogfruit changed from 3-methylbutanal and methanol in the unripe state to acetaldehyde and ethanol in the ripe bean. Moreover, the amount of the typical volatile flavor compound 1,2,4-trithiolane significantly increased (P < 0.05 in both ripened dogfruit and stink bean from 1.70 and 0.93%, to relative amounts of 19.97 and 13.66%, respectively. MS-based nose profiling gave further detailed differentiation of the volatile profiles of dogfruit and stink bean of various ripening stages through multivariate statistical analysis, and provided discriminant ion masses, such as m/z 41, 43, 58, 78, and 124, as valuable “digital fingerprint” dataset that can be used for fast flavor monitoring of smelly food resources.

  1. A Novel Feature Extraction Approach Using Window Function Capturing and QPSO-SVM for Enhancing Electronic Nose Performance

    Directory of Open Access Journals (Sweden)

    Xiuzhen Guo

    2015-06-01

    Full Text Available In this paper, a novel feature extraction approach which can be referred to as moving window function capturing (MWFC has been proposed to analyze signals of an electronic nose (E-nose used for detecting types of infectious pathogens in rat wounds. Meanwhile, a quantum-behaved particle swarm optimization (QPSO algorithm is implemented in conjunction with support vector machine (SVM for realizing a synchronization optimization of the sensor array and SVM model parameters. The results prove the efficacy of the proposed method for E-nose feature extraction, which can lead to a higher classification accuracy rate compared to other established techniques. Meanwhile it is interesting to note that different classification results can be obtained by changing the types, widths or positions of windows. By selecting the optimum window function for the sensor response, the performance of an E-nose can be enhanced.

  2. Diagnosing viral and bacterial respiratory infections in acute COPD exacerbations by an electronic nose: a pilot study.

    Science.gov (United States)

    van Geffen, Wouter H; Bruins, Marcel; Kerstjens, Huib A M

    2016-06-16

    Respiratory infections, viral or bacterial, are a common cause of acute exacerbations of chronic obstructive pulmonary disease (AECOPD). A rapid, point-of-care, and easy-to-use tool distinguishing viral and bacterial from other causes would be valuable in routine clinical care. An electronic nose (e-nose) could fit this profile but has never been tested in this setting before. In a single-center registered trial (NTR 4601) patients admitted with AECOPD were tested with the Aeonose(®) electronic nose, and a diagnosis of viral or bacterial infection was obtained by bacterial culture on sputa and viral PCR on nose swabs. A neural network with leave-10%-out cross-validation was used to assess the e-nose data. Forty three patients were included. In the bacterial infection model, 22 positive cases were tested versus the negatives; and similarly 18 positive cases were tested in the viral infection model. The Aeonose was able to distinguish between COPD-subjects suffering from a viral infection and COPD patients without infection, showing an area under the curve (AUC) of 0.74. Similarly, for bacterial infections, an AUC of 0.72 was obtained. The Aeonose e-nose yields promising results in 'smelling' the presence or absence of a viral or bacterial respiratory infection during an acute exacerbation of COPD. Validation of these results using a new and large cohort is required before introduction into clinical practice.

  3. Mining Data of Noisy Signal Patterns in Recognition of Gasoline Bio-Based Additives using Electronic Nose

    Directory of Open Access Journals (Sweden)

    Osowski Stanisław

    2017-03-01

    Full Text Available The paper analyses the distorted data of an electronic nose in recognizing the gasoline bio-based additives. Different tools of data mining, such as the methods of data clustering, principal component analysis, wavelet transformation, support vector machine and random forest of decision trees are applied. A special stress is put on the robustness of signal processing systems to the noise distorting the registered sensor signals. A special denoising procedure based on application of discrete wavelet transformation has been proposed. This procedure enables to reduce the error rate of recognition in a significant way. The numerical results of experiments devoted to the recognition of different blends of gasoline have shown the superiority of support vector machine in a noisy environment of measurement.

  4. Rapid direct analysis to discriminate geographic origin of extra virgin olive oils by flash gas chromatography electronic nose and chemometrics.

    Science.gov (United States)

    Melucci, Dora; Bendini, Alessandra; Tesini, Federica; Barbieri, Sara; Zappi, Alessandro; Vichi, Stefania; Conte, Lanfranco; Gallina Toschi, Tullia

    2016-08-01

    At present, the geographical origin of extra virgin olive oils can be ensured by documented traceability, although chemical analysis may add information that is useful for possible confirmation. This preliminary study investigated the effectiveness of flash gas chromatography electronic nose and multivariate data analysis to perform rapid screening of commercial extra virgin olive oils characterized by a different geographical origin declared in the label. A comparison with solid phase micro extraction coupled to gas chromatography mass spectrometry was also performed. The new method is suitable to verify the geographic origin of extra virgin olive oils based on principal components analysis and discriminant analysis applied to the volatile profile of the headspace as a fingerprint. The selected variables were suitable in discriminating between "100% Italian" and "non-100% Italian" oils. Partial least squares discriminant analysis also allowed prediction of the degree of membership of unknown samples to the classes examined. Copyright © 2016. Published by Elsevier Ltd.

  5. Advances in Electronic-Nose Technologies for the Detection of Volatile Biomarker Metabolites in the Human Breath

    Directory of Open Access Journals (Sweden)

    Alphus D. Wilson

    2015-03-01

    Full Text Available Recent advancements in the use of electronic-nose (e-nose devices to analyze human breath profiles for the presence of specific volatile metabolites, known as biomarkers or chemical bio-indicators of specific human diseases, metabolic disorders and the overall health status of individuals, are providing the potential for new noninvasive tools and techniques useful to point-of-care clinical disease diagnoses. This exciting new area of electronic disease detection and diagnosis promises to yield much faster and earlier detection of human diseases and disorders, allowing earlier, more effective treatments, resulting in more rapid patient recovery from various afflictions. E-nose devices are particularly suited for the field of disease diagnostics, because they are sensitive to a wide range of volatile organic compounds (VOCs and can effectively distinguish between different complex gaseous mixtures via analysis of electronic aroma sensor-array output profiles of volatile metabolites present in the human breath. This review provides a summary of some recent developments of electronic-nose technologies, particularly involving breath analysis, with the potential for providing many new diagnostic applications for the detection of specific human diseases associated with different organs in the body, detectable from e-nose analyses of aberrant disease-associated VOCs present in air expired from the lungs.

  6. Exhaled breath analysis using electronic nose in cystic fibrosis and primary ciliary dyskinesia patients with chronic pulmonary infections

    DEFF Research Database (Denmark)

    Joensen, Odin; Paff, Tamara; Haarman, Eric G

    2014-01-01

    The current diagnostic work-up and monitoring of pulmonary infections may be perceived as invasive, is time consuming and expensive. In this explorative study, we investigated whether or not a non-invasive exhaled breath analysis using an electronic nose would discriminate between cystic fibrosis...... (CF) and primary ciliary dyskinesia (PCD) with or without various well characterized chronic pulmonary infections. We recruited 64 patients with CF and 21 with PCD based on known chronic infection status. 21 healthy volunteers served as controls. An electronic nose was employed to analyze exhaled......, this method significantly discriminates CF patients suffering from a chronic pulmonary P. aeruginosa (PA) infection from CF patients without a chronic pulmonary infection. Further studies are needed for verification and to investigate the role of electronic nose technology in the very early diagnostic workup...

  7. Validation of exhaled volatile organic compounds analysis using electronic nose as index of COPD severity

    Directory of Open Access Journals (Sweden)

    Finamore P

    2018-05-01

    Full Text Available Panaiotis Finamore,1 Claudio Pedone,1 Simone Scarlata,1 Alessandra Di Paolo,1 Simone Grasso,2 Marco Santonico,2 Giorgio Pennazza,2 Raffaele Antonelli Incalzi1 1Unit of Geriatrics, Campus Bio-Medico di Roma University, Rome, Italy; 2Unit of Electronics for Sensor Systems, Campus Bio-Medico di Roma University, Rome, Italy Aim: Six-minute walking test distance (6MWD and body mass index, obstruction, dyspnea and exercise (BODE index are measures of functional status in COPD patients, but require space, time and patient’s compliance. Exhaled volatile organic compounds (VOCs analysis via electronic nose is a quick and easy method that has already been used to discriminate COPD phenotypes. The aim of this study is to evaluate whether VOCs analysis can predict functional status and its variation over time in COPD patients.Methods: A monocentric prospective study with 1 year of follow-up was carried out. All patients underwent pulmonary function tests, arterial gas analysis, bioimpedance analysis, 6-minute walking test, and VOCs collection. Exhaled breath was collected with Pneumopipe® and analyzed using BIONOTE electronic nose. Outcomes prediction was performed by k-fold cross-validated partial least square discriminant analysis: accuracy, sensitivity and specificity as well as Cohen’s kappa for agreement were calculated.Results: We enrolled 63 patients, 60.3% men, with a mean age of 71 (SD: 8 years, median BODE index of 1 (interquartile range: 0–3 and mean 6MWD normalized by squared height (n6MWD of 133.5 (SD: 42 m/m2. The BIONOTE predicted baseline BODE score (dichotomized as BODE score <3 or ≥3 with an accuracy of 86% and quartiles of n6MWD with an accuracy of 79%. n6MWD decline more than the median value after 1 year was predicted with an accuracy of 86% by BIONOTE, 52% by Global Initiative for Chronic Obstructive Lung Disease (GOLD class and 78% by combined BIONOTE and GOLD class.Conclusion: Exhaled VOCs analysis identifies classes of BODE

  8. Volatile Discrimination of Irradiated and Fumigated White Ginseng Powders at Different Storage Times and Temperatures Using the Electronic Nose

    International Nuclear Information System (INIS)

    Kwon, J.H.; Shin, J.A.; Lee, K.T.

    2006-01-01

    The pattern of volatile emissions from white ginseng powders (WGP) that were treated with selected preservatives was investigated during 5-months of storage (at-10 and 25℃) by an electronic nose system equipped with 12 metal-oxide sensors. WGP were treated with gamma radiation at 5 kGy, commercial methyl bromide (MeBr), and phosphine fumigations. Electronic nose differentiated the volatile patterns of the WGP with each different preservative treatment. In addition, each volatile pattern was affected by both storage time (1, 2 and 5 months) and temperature (-10 and 25℃)

  9. Development of fabric-based chemical gas sensors for use as wearable electronic noses.

    Science.gov (United States)

    Seesaard, Thara; Lorwongtragool, Panida; Kerdcharoen, Teerakiat

    2015-01-16

    Novel gas sensors embroidered into fabric substrates based on polymers/ SWNT-COOH nanocomposites were proposed in this paper, aiming for their use as a wearable electronic nose (e-nose). The fabric-based chemical gas sensors were fabricated by two main processes: drop coating and embroidery. Four potential polymers (PVC, cumene-PSMA, PSE and PVP)/functionalized-SWCNT sensing materials were deposited onto interdigitated electrodes previously prepared by embroidering conductive thread on a fabric substrate to make an optimal set of sensors. After preliminary trials of the obtained sensors, it was found that the sensors yielded a electrical resistance in the region of a few kilo-Ohms. The sensors were tested with various volatile compounds such as ammonium hydroxide, ethanol, pyridine, triethylamine, methanol and acetone, which are commonly found in the wastes released from the human body. These sensors were used to detect and discriminate between the body odors of different regions and exist in various forms such as the urine, armpit and exhaled breath odor. Based on a simple pattern recognition technique, we have shown that the proposed fabric-based chemical gas sensors can discriminate the human body odor from two persons.

  10. Development of Fabric-Based Chemical Gas Sensors for Use as Wearable Electronic Noses

    Directory of Open Access Journals (Sweden)

    Thara Seesaard

    2015-01-01

    Full Text Available Novel gas sensors embroidered into fabric substrates based on polymers/ SWNT-COOH nanocomposites were proposed in this paper, aiming for their use as a wearable electronic nose (e-nose. The fabric-based chemical gas sensors were fabricated by two main processes: drop coating and embroidery. Four potential polymers (PVC, cumene-PSMA, PSE and PVP/functionalized-SWCNT sensing materials were deposited onto interdigitated electrodes previously prepared by embroidering conductive thread on a fabric substrate to make an optimal set of sensors. After preliminary trials of the obtained sensors, it was found that the sensors yielded a electrical resistance in the region of a few kilo-Ohms. The sensors were tested with various volatile compounds such as ammonium hydroxide, ethanol, pyridine, triethylamine, methanol and acetone, which are commonly found in the wastes released from the human body. These sensors were used to detect and discriminate between the body odors of different regions and exist in various forms such as the urine, armpit and exhaled breath odor. Based on a simple pattern recognition technique, we have shown that the proposed fabric-based chemical gas sensors can discriminate the human body odor from two persons.

  11. Classification of root canal microorganisms using electronic-nose and discriminant analysis

    Directory of Open Access Journals (Sweden)

    Özbilge Hatice

    2010-11-01

    Full Text Available Abstract Background Root canal treatment is a debridement process which disrupts and removes entire microorganisms from the root canal system. Identification of microorganisms may help clinicians decide on treatment alternatives such as using different irrigants, intracanal medicaments and antibiotics. However, the difficulty in cultivation and the complexity in isolation of predominant anaerobic microorganisms make clinicians resort to empirical medical treatments. For this reason, identification of microorganisms is not a routinely used procedure in root canal treatment. In this study, we aimed at classifying 7 different standard microorganism strains which are frequently seen in root canal infections, using odor data collected using an electronic nose instrument. Method Our microorganism odor data set consisted of 5 repeated samples from 7 different classes at 4 concentration levels. For each concentration, 35 samples were classified using 3 different discriminant analysis methods. In order to determine an optimal setting for using electronic-nose in such an application, we have tried 3 different approaches in evaluating sensor responses. Moreover, we have used 3 different sensor baseline values in normalizing sensor responses. Since the number of sensors is relatively large compared to sample size, we have also investigated the influence of two different dimension reduction methods on classification performance. Results We have found that quadratic type dicriminant analysis outperforms other varieties of this method. We have also observed that classification performance decreases as the concentration decreases. Among different baseline values used for pre-processing the sensor responses, the model where the minimum values of sensor readings in the sample were accepted as the baseline yields better classification performance. Corresponding to this optimal choice of baseline value, we have noted that among different sensor response model and

  12. A conductive polymer based electronic nose for early detection of Penicillium digitatum in post-harvest oranges

    International Nuclear Information System (INIS)

    Gruber, Jonas; Nascimento, Henry M.; Yamauchi, Elaine Y.; Li, Rosamaria W.C.; Esteves, Carlos H.A.; Rehder, Gustavo P.; Gaylarde, Christine C.; Shirakawa, Márcia A.

    2013-01-01

    We describe the construction of an electronic nose, comprising four chemiresistive sensors formed by the deposition of thin conductive polymer films onto interdigitated electrodes, attached to a personal computer via a data acquisition board. This e-nose was used to detect biodeterioration of oranges colonized by Penicillium digitatum. Significant responses were obtained after only 24 h of incubation i.e. at an early stage of biodeterioration, enabling remedial measures to be taken in storage facilities and efficiently distinguishing between good and poor quality fruits. The instrument has a very low analysis time of 40 s. - Highlights: • Early detection of Penicillium digitatum in oranges • Low cost electronic nose based on conductive polymers • Efficient distinction between good and poor quality fruits

  13. A conductive polymer based electronic nose for early detection of Penicillium digitatum in post-harvest oranges

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, Jonas, E-mail: jogruber@iq.usp.br [Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP (Brazil); Nascimento, Henry M. [Sociedade Brasileira de Microbiologia, São Paulo, SP (Brazil); Yamauchi, Elaine Y. [Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP (Brazil); Li, Rosamaria W.C. [Centro Universitário Estácio Radial São Paulo, São Paulo, SP (Brazil); Esteves, Carlos H.A. [Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes, 748, CEP 05508-000 São Paulo, SP (Brazil); Rehder, Gustavo P. [Escola Politécnica, Universidade de São Paulo, São Paulo, SP (Brazil); Gaylarde, Christine C. [University of Portsmouth, Portsmouth (United Kingdom); Shirakawa, Márcia A. [Escola Politécnica, Universidade de São Paulo, São Paulo, SP (Brazil)

    2013-07-01

    We describe the construction of an electronic nose, comprising four chemiresistive sensors formed by the deposition of thin conductive polymer films onto interdigitated electrodes, attached to a personal computer via a data acquisition board. This e-nose was used to detect biodeterioration of oranges colonized by Penicillium digitatum. Significant responses were obtained after only 24 h of incubation i.e. at an early stage of biodeterioration, enabling remedial measures to be taken in storage facilities and efficiently distinguishing between good and poor quality fruits. The instrument has a very low analysis time of 40 s. - Highlights: • Early detection of Penicillium digitatum in oranges • Low cost electronic nose based on conductive polymers • Efficient distinction between good and poor quality fruits.

  14. Electronic nose as an innovative tool for the diagnosis of grapevine crown gall

    Energy Technology Data Exchange (ETDEWEB)

    Blasioli, S., E-mail: sonia.blasioli@unibo.it [Dipartimento di Scienze e Tecnologie Agroambientali, Universita di Bologna, V.le Fanin, 44, 40127 Bologna (Italy); Biondi, E., E-mail: erbiondi@tin.it [Dipartimento di Scienze e Tecnologie Agroambientali, Universita di Bologna, V.le Fanin, 44, 40127 Bologna (Italy); Braschi, I., E-mail: ilaria.braschi@unibo.it [Dipartimento di Scienze e Tecnologie Agroambientali, Universita di Bologna, V.le Fanin, 44, 40127 Bologna (Italy); Mazzucchi, U., E-mail: umberto.mazzucchi@unibo.it [Dipartimento di Scienze e Tecnologie Agroambientali, Universita di Bologna, V.le Fanin, 44, 40127 Bologna (Italy); Bazzi, C., E-mail: carlo.bazzi@unibo.it [Dipartimento di Scienze e Tecnologie Agroambientali, Universita di Bologna, V.le Fanin, 44, 40127 Bologna (Italy); Gessa, C.E., E-mail: carloemanuele.gessa@unibo.it [Dipartimento di Scienze e Tecnologie Agroambientali, Universita di Bologna, V.le Fanin, 44, 40127 Bologna (Italy)

    2010-07-05

    For the first time, a portable electronic nose was used to discriminate between healthy and galled grapevines, experimentally inoculated with two tumourigenic strains of Agrobacterium vitis. The volatile profile of target cutting samples was analysed by headspace solid phase microextraction coupled with gas chromatography-mass spectrometry. Spectra from tumoured samples revealed the presence of styrene which is compatible with decarboxylation of cinnamic acid involved in secondary metabolism of plants. Principal Component Analysis confirmed the difference in volatile profiles of infected vines and their healthy controls. Linear Discriminant Analysis allowed the correct discrimination between healthy and galled grapevines (83.3%, cross-validation). Although a larger number of samples should be analysed to create a more robust model, our results give novel interesting clues to go further with research on the diagnostic potential of this innovative system associated with multi-dimensional chemometric techniques.

  15. Tracking Dynamic Source Direction with a Novel Stationary Electronic Nose System

    Directory of Open Access Journals (Sweden)

    David C. Levy

    2006-11-01

    Full Text Available Arrays of chemical sensors, usually called electronic noses (ENose, are widelyused in industry for classifying and identifying odours. They may also be used to locate theposition and detect the direction of an emission source. Usually this task is performed by anENose cooperating with a mobile vehicle, but when a source is instantaneous, or thesurrounding terrain is hard for vehicles to traverse, an alternative approach is needed. Thus athree-step method for a stationary ENose with a novel structure to detect the direction of adynamic source is presented in this paper. The method uses the ratio of measuredconcentration from different sensors (Cn /C1 where n=2, 4 as a discriminator. In addition,this method could easily be adapted to robotics as an optimized algorithm for path trackingto a source location. The paper presents the results of a simulation of the method.

  16. Development of an electronic nose sensing platform for undergraduate education in nanotechnology

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Daniel V; Burek, Michael J; Iutzi, Ryan M; Mracek, James A; Hesjedal, Thorsten, E-mail: thesjeda@uwaterloo.ca [Nanotechnology Engineering Program and Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1 (Canada)

    2011-05-15

    The teaching of the different aspects of a sensor system, with a focus on the involved nanotechnology, is a challenging, yet important task. We present the development of an electronic nose system that utilizes a nanoscale amperometric sensing mechanism for gas mixtures. The fabrication of the system makes use of a basic microfabrication facility, as well as an undergraduate chemistry laboratory for material synthesis and preparation. The sensing device consists of an array of cross-reactive sensors composed of metal-oxide semiconducting nanoparticles. Each sensor in the array produces a unique response in the presence of a target gas, allowing the sensor to determine the identity and concentration of multiple gases in a mixture. The educational aspects include microheater simulation and fabrication, design and fabrication of interdigitated electrodes, development of interfacing circuitry and software, development and calibration of a sensory array, sol-gel processing of nanoparticle films and their characterization, and details of the fundamental chemical sensing mechanism.

  17. Molecular modeling of interactions in electronic nose sensors for environmental monitoring

    Science.gov (United States)

    Shevade, A. V.; Ryan, M. A.; Homer, M. L.; Manfreda, A. M.; Yen, S. -P. S.; Zhou, H.; Manatt, K.

    2002-01-01

    We report a study aimed at understanding analyte interactions with sensors made from polymer-carbon black composite films. The sensors are used in an Electronic Nose (ENose) which is used for monitoring the breathing air quality in human habitats. The model mimics the experimental conditions of the composite film deposition and formation and was developed using molecular modeling and simulation tools. The Dreiding 2.21 Force Field was used for the polymer and analyte molecules while graphite parameters were assigned to the carbon black atoms. The polymer considered for this work is methyl vinyl ether / maleic acid copolymer. The target analytes include both inorganic (NH3) and organic (methanol) types of compound. Results indicate different composite-analyte interaction behavior.

  18. Monitoring space shuttle air quality using the Jet Propulsion Laboratory electronic nose

    Science.gov (United States)

    Ryan, Margaret Amy; Zhou, Hanying; Buehler, Martin G.; Manatt, Kenneth S.; Mowrey, Victoria S.; Jackson, Shannon P.; Kisor, Adam K.; Shevade, Abhijit V.; Homer, Margie L.

    2004-01-01

    A miniature electronic nose (ENose) has been designed and built at the Jet Propulsion Laboratory (JPL), Pasadena, CA, and was designed to detect, identify, and quantify ten common contaminants and relative humidity changes. The sensing array includes 32 sensing films made from polymer carbon-black composites. Event identification and quantification were done using the Levenberg-Marquart nonlinear least squares method. After successful ground training, this ENose was used in a demonstration experiment aboard STS-95 (October-November, 1998), in which the ENose was operated continuously for six days and recorded the sensors' response to the air in the mid-deck. Air samples were collected daily and analyzed independently after the flight. Changes in shuttle-cabin humidity were detected and quantified by the JPL ENose; neither the ENose nor the air samples detected any of the contaminants on the target list. The device is microgravity insensitive.

  19. Calibration transfer between electronic nose systems for rapid In situ measurement of pulp and paper industry emissions

    Energy Technology Data Exchange (ETDEWEB)

    Deshmukh, Sharvari [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata (India); Kamde, Kalyani [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Jana, Arun [Center for Development of Advance Computing, Kolkata (India); Korde, Sanjivani [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Bandyopadhyay, Rajib [Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata (India); Sankar, Ravi [Center for Development of Advance Computing, Kolkata (India); Bhattacharyya, Nabarun, E-mail: nabarun.bhattacharya@cdac.in [Center for Development of Advance Computing, Kolkata (India); Pandey, R.A., E-mail: ra_pandey@neeri.res.in [CSIR-National Environmental Engineering and Research Institute, Nagpur (India)

    2014-09-02

    Highlights: • E-nose developed for obnoxious emissions measurement at pulp and paper industrial site. • ANN model developed for prediction of (CH{sub 3}){sub 2}S, (CH{sub 3}){sub 2}S{sub 2}, CH{sub 3}SH and H{sub 2}S concentration. • Calibration transfer methodology developed for transfer between two e-nose instruments. • Box–Behnken design and robust regression used for calibration transfer. • Results show effective transfer of training model from one e-nose system to other. - Abstract: Electronic nose systems when deployed in network mesh can effectively provide a low budget and onsite solution for the industrial obnoxious gaseous measurement. For accurate and identical prediction capability by all the electronic nose systems, a reliable calibration transfer model needs to be implemented in order to overcome the inherent sensor array variability. In this work, robust regression (RR) is used for calibration transfer between two electronic nose systems using a Box–Behnken (BB) design. Out of the two electronic nose systems, one was trained using industrial gas samples by four artificial neural network models, for the measurement of obnoxious odours emitted from pulp and paper industries. The emissions constitute mainly of hydrogen sulphide (H{sub 2}S), methyl mercaptan (MM), dimethyl sulphide (DMS) and dimethyl disulphide (DMDS) in different proportions. A Box–Behnken design consisting of 27 experiment sets based on synthetic gas combinations of H{sub 2}S, MM, DMS and DMDS, were conducted for calibration transfer between two identical electronic nose systems. Identical sensors on both the systems were mapped and the prediction models developed using ANN were then transferred to the second system using BB–RR methodology. The results showed successful transmission of prediction models developed for one system to other system, with the mean absolute error between the actual and predicted concentration of analytes in mg L{sup −1} after calibration

  20. Diagnosing viral and bacterial respiratory infections in acute COPD exacerbations by an electronic nose : a pilot study

    NARCIS (Netherlands)

    van Geffen, Wouter H; Bruins, Marcel; Kerstjens, Huib A M

    2016-01-01

    Respiratory infections, viral or bacterial, are a common cause of acute exacerbations of chronic obstructive pulmonary disease (AECOPD). A rapid, point-of-care, and easy-to-use tool distinguishing viral and bacterial from other causes would be valuable in routine clinical care. An electronic nose

  1. ``Low-cost Electronic nose evaluated on Thai-herb of Northern-Thailand samples using multivariate analysis methods''

    Science.gov (United States)

    na ayudhaya, Paisarn Daungjak; Klinbumrung, Arrak; Jaroensutasinee, Krisanadej; Pratontep, Sirapat; Kerdcharoen, Teerakiat

    2009-05-01

    In case of species of natural and aromatic plant originated from the northern Thailand, sensory characteristics, especially odours, have unique identifiers of herbs. The instruments sensory analysis have performed by several of differential of sensing, so call `electronic nose', to be a significantly and rapidly for chemometrics. The signal responses of the low cost electronic nose were evaluated by principal component analysis (PCA). The aims of this paper evaluated various of Thai-herbs grown in Northern of Thailand as data preprocessing tools of the Low-cost electronic nose (enNU-PYO1). The essential oil groups of Thai herbs such as Garlic, Lemongrass, Shallot (potato onion), Onion, Zanthoxylum limonella (Dennst.) Alston (Thai name is Makaen), and Kaffir lime leaf were compared volatilized from selected fresh herbs. Principal component analysis of the original sensor responses did clearly distinguish either all samples. In all cases more than 97% for cross-validated group were classified correctly. The results demonstrated that it was possible to develop in a model to construct a low-cost electronic nose to provide measurement of odoriferous herbs.

  2. Ultra-Low-Power Smart Electronic Nose System Based on Three-Dimensional Tin Oxide Nanotube Arrays.

    Science.gov (United States)

    Chen, Jiaqi; Chen, Zhuo; Boussaid, Farid; Zhang, Daquan; Pan, Xiaofang; Zhao, Huijuan; Bermak, Amine; Tsui, Chi-Ying; Wang, Xinran; Fan, Zhiyong

    2018-06-04

    In this work, we present a high-performance smart electronic nose (E-nose) system consisting of a multiplexed tin oxide (SnO 2 ) nanotube sensor array, read-out circuit, wireless data transmission unit, mobile phone receiver, and data processing application (App). Using the designed nanotube sensor device structure in conjunction with multiple electrode materials, high-sensitivity gas detection and discrimination have been achieved at room temperature, enabling a 1000 times reduction of the sensor's power consumption as compared to a conventional device using thin film SnO 2 . The experimental results demonstrate that the developed E-nose can identify indoor target gases using a simple vector-matching gas recognition algorithm. In addition, the fabricated E-nose has achieved state-of-the-art sensitivity for H 2 and benzene detection at room temperature with metal oxide sensors. Such a smart E-nose system can address the imperative needs for distributed environmental monitoring in smart homes, smart buildings, and smart cities.

  3. Rapid and accurate detection of urinary pathogens by mobile IMS-based electronic nose: a proof-of-principle study.

    Science.gov (United States)

    Roine, Antti; Saviauk, Taavi; Kumpulainen, Pekka; Karjalainen, Markus; Tuokko, Antti; Aittoniemi, Janne; Vuento, Risto; Lekkala, Jukka; Lehtimäki, Terho; Tammela, Teuvo L; Oksala, Niku K J

    2014-01-01

    Urinary tract infection (UTI) is a common disease with significant morbidity and economic burden, accounting for a significant part of the workload in clinical microbiology laboratories. Current clinical chemisty point-of-care diagnostics rely on imperfect dipstick analysis which only provides indirect and insensitive evidence of urinary bacterial pathogens. An electronic nose (eNose) is a handheld device mimicking mammalian olfaction that potentially offers affordable and rapid analysis of samples without preparation at athmospheric pressure. In this study we demonstrate the applicability of ion mobility spectrometry (IMS) -based eNose to discriminate the most common UTI pathogens from gaseous headspace of culture plates rapidly and without sample preparation. We gathered a total of 101 culture samples containing four most common UTI bacteries: E. coli, S. saprophyticus, E. faecalis, Klebsiella spp and sterile culture plates. The samples were analyzed using ChemPro 100i device, consisting of IMS cell and six semiconductor sensors. Data analysis was conducted by linear discriminant analysis (LDA) and logistic regression (LR). The results were validated by leave-one-out and 5-fold cross validation analysis. In discrimination of sterile and bacterial samples sensitivity of 95% and specificity of 97% were achieved. The bacterial species were identified with sensitivity of 95% and specificity of 96% using eNose as compared to urine bacterial cultures. These findings strongly demonstrate the ability of our eNose to discriminate bacterial cultures and provides a proof of principle to use this method in urinanalysis of UTI.

  4. Rapid and accurate detection of urinary pathogens by mobile IMS-based electronic nose: a proof-of-principle study.

    Directory of Open Access Journals (Sweden)

    Antti Roine

    Full Text Available Urinary tract infection (UTI is a common disease with significant morbidity and economic burden, accounting for a significant part of the workload in clinical microbiology laboratories. Current clinical chemisty point-of-care diagnostics rely on imperfect dipstick analysis which only provides indirect and insensitive evidence of urinary bacterial pathogens. An electronic nose (eNose is a handheld device mimicking mammalian olfaction that potentially offers affordable and rapid analysis of samples without preparation at athmospheric pressure. In this study we demonstrate the applicability of ion mobility spectrometry (IMS -based eNose to discriminate the most common UTI pathogens from gaseous headspace of culture plates rapidly and without sample preparation. We gathered a total of 101 culture samples containing four most common UTI bacteries: E. coli, S. saprophyticus, E. faecalis, Klebsiella spp and sterile culture plates. The samples were analyzed using ChemPro 100i device, consisting of IMS cell and six semiconductor sensors. Data analysis was conducted by linear discriminant analysis (LDA and logistic regression (LR. The results were validated by leave-one-out and 5-fold cross validation analysis. In discrimination of sterile and bacterial samples sensitivity of 95% and specificity of 97% were achieved. The bacterial species were identified with sensitivity of 95% and specificity of 96% using eNose as compared to urine bacterial cultures.These findings strongly demonstrate the ability of our eNose to discriminate bacterial cultures and provides a proof of principle to use this method in urinanalysis of UTI.

  5. Electronic nose with a new feature reduction method and a multi-linear classifier for Chinese liquor classification

    Energy Technology Data Exchange (ETDEWEB)

    Jing, Yaqi; Meng, Qinghao, E-mail: qh-meng@tju.edu.cn; Qi, Peifeng; Zeng, Ming; Li, Wei; Ma, Shugen [Tianjin Key Laboratory of Process Measurement and Control, Institute of Robotics and Autonomous Systems, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072 (China)

    2014-05-15

    An electronic nose (e-nose) was designed to classify Chinese liquors of the same aroma style. A new method of feature reduction which combined feature selection with feature extraction was proposed. Feature selection method used 8 feature-selection algorithms based on information theory and reduced the dimension of the feature space to 41. Kernel entropy component analysis was introduced into the e-nose system as a feature extraction method and the dimension of feature space was reduced to 12. Classification of Chinese liquors was performed by using back propagation artificial neural network (BP-ANN), linear discrimination analysis (LDA), and a multi-linear classifier. The classification rate of the multi-linear classifier was 97.22%, which was higher than LDA and BP-ANN. Finally the classification of Chinese liquors according to their raw materials and geographical origins was performed using the proposed multi-linear classifier and classification rate was 98.75% and 100%, respectively.

  6. Electronic nose with a new feature reduction method and a multi-linear classifier for Chinese liquor classification

    International Nuclear Information System (INIS)

    Jing, Yaqi; Meng, Qinghao; Qi, Peifeng; Zeng, Ming; Li, Wei; Ma, Shugen

    2014-01-01

    An electronic nose (e-nose) was designed to classify Chinese liquors of the same aroma style. A new method of feature reduction which combined feature selection with feature extraction was proposed. Feature selection method used 8 feature-selection algorithms based on information theory and reduced the dimension of the feature space to 41. Kernel entropy component analysis was introduced into the e-nose system as a feature extraction method and the dimension of feature space was reduced to 12. Classification of Chinese liquors was performed by using back propagation artificial neural network (BP-ANN), linear discrimination analysis (LDA), and a multi-linear classifier. The classification rate of the multi-linear classifier was 97.22%, which was higher than LDA and BP-ANN. Finally the classification of Chinese liquors according to their raw materials and geographical origins was performed using the proposed multi-linear classifier and classification rate was 98.75% and 100%, respectively

  7. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD.

    Science.gov (United States)

    Dragonieri, Silvano; Annema, Jouke T; Schot, Robert; van der Schee, Marc P C; Spanevello, Antonio; Carratú, Pierluigi; Resta, Onofrio; Rabe, Klaus F; Sterk, Peter J

    2009-05-01

    Exhaled breath contains thousands of gaseous volatile organic compounds (VOCs) that may be used as non-invasive markers of lung disease. The electronic nose analyzes VOCs by composite nano-sensor arrays with learning algorithms. It has been shown that an electronic nose can distinguish the VOCs pattern in exhaled breath of lung cancer patients from healthy controls. We hypothesized that an electronic nose can discriminate patients with lung cancer from COPD patients and healthy controls by analyzing the VOC-profile in exhaled breath. 30 subjects participated in a cross-sectional study: 10 patients with non-small cell lung cancer (NSCLC, [age 66.4+/-9.0, FEV(1) 86.3+/-20.7]), 10 patients with COPD (age 61.4+/-5.5, FEV(1) 70.0+/-14.8) and 10 healthy controls (age 58.3+/-8.1, FEV(1) 108.9+/-14.6). After 5 min tidal breathing through a non-rebreathing valve with inspiratory VOC-filter, subjects performed a single vital capacity maneuver to collect dried exhaled air into a Tedlar bag. The bag was connected to the electronic nose (Cyranose 320) within 10 min, with VOC-filtered room air as baseline. The smellprints were analyzed by onboard statistical software. Smellprints from NSCLC patients clustered distinctly from those of COPD subjects (cross validation value [CVV]: 85%; M-distance: 3.73). NSCLC patients could also be discriminated from healthy controls in duplicate measurements (CVV: 90% and 80%, respectively; M-distance: 2.96 and 2.26). VOC-patterns of exhaled breath discriminates patients with lung cancer from COPD patients as well as healthy controls. The electronic nose may qualify as a non-invasive diagnostic tool for lung cancer in the future.

  8. A Novel Method for the Discrimination of Semen Arecae and Its Processed Products by Using Computer Vision, Electronic Nose, and Electronic Tongue

    Directory of Open Access Journals (Sweden)

    Min Xu

    2015-01-01

    Full Text Available Areca nut, commonly known locally as Semen Arecae (SA in China, has been used as an important Chinese herbal medicine for thousands of years. The raw SA (RAW is commonly processed by stir-baking to yellow (SBY, stir-baking to dark brown (SBD, and stir-baking to carbon dark (SBC for different clinical uses. In our present investigation, intelligent sensory technologies consisting of computer vision (CV, electronic nose (E-nose, and electronic tongue (E-tongue were employed in order to develop a novel and accurate method for discrimination of SA and its processed products. Firstly, the color parameters and electronic sensory responses of E-nose and E-tongue of the samples were determined, respectively. Then, indicative components including 5-hydroxymethyl furfural (5-HMF and arecoline (ARE were determined by HPLC. Finally, principal component analysis (PCA and discriminant factor analysis (DFA were performed. The results demonstrated that these three instruments can effectively discriminate SA and its processed products. 5-HMF and ARE can reflect the stir-baking degree of SA. Interestingly, the two components showed close correlations to the color parameters and sensory responses of E-nose and E-tongue. In conclusion, this novel method based on CV, E-nose, and E-tongue can be successfully used to discriminate SA and its processed products.

  9. Geographical origin of Sauvignon Blanc wines predicted by mass spectrometry and metal oxide based electronic nose

    Energy Technology Data Exchange (ETDEWEB)

    Berna, Amalia Z., E-mail: Amalia.Berna@csiro.au [CSIRO Entomology and Food Futures Flagship, PO Box 1700, Canberra, ACT 2601 (Australia); Trowell, Stephen [CSIRO Entomology and Food Futures Flagship, PO Box 1700, Canberra, ACT 2601 (Australia); Clifford, David [CSIRO Mathematical and Information Sciences, Locked Bag 17, North Ryde, NSW 1670 (Australia); Cynkar, Wies; Cozzolino, Daniel [The Australian Wine Research Institute, Waite Road, Urrbrae, PO Box 197, Adelaide, SA 5064 (Australia)

    2009-08-26

    Analysis of 34 Sauvignon Blanc wine samples from three different countries and six regions was performed by gas chromatography-mass spectrometry (GC-MS). Linear discriminant analysis (LDA) showed that there were three distinct clusters or classes of wines with different aroma profiles. Wines from the Loire region in France and Australian wines from Tasmania and Western Australia were found to have similar aroma patterns. New Zealand wines from the Marlborough region as well as the Australian ones from Victoria were grouped together based on the volatile composition. Wines from South Australia region formed one discrete class. Seven analytes, most of them esters, were found to be the relevant chemical compounds that characterized the classes. The grouping information obtained by GC-MS, was used to train metal oxide based electronic (MOS-Enose) and mass spectrometry based electronic (MS-Enose) noses. The combined use of solid phase microextraction (SPME) and ethanol removal prior to MOS-Enose analysis, allowed an average error of prediction of the regional origins of Sauvignon Blanc wines of 6.5% compared to 24% when static headspace (SHS) was employed. For MS-Enose, the misclassification rate was higher probably due to the requirement to delimit the m/z range considered.

  10. Geographical origin of Sauvignon Blanc wines predicted by mass spectrometry and metal oxide based electronic nose

    International Nuclear Information System (INIS)

    Berna, Amalia Z.; Trowell, Stephen; Clifford, David; Cynkar, Wies; Cozzolino, Daniel

    2009-01-01

    Analysis of 34 Sauvignon Blanc wine samples from three different countries and six regions was performed by gas chromatography-mass spectrometry (GC-MS). Linear discriminant analysis (LDA) showed that there were three distinct clusters or classes of wines with different aroma profiles. Wines from the Loire region in France and Australian wines from Tasmania and Western Australia were found to have similar aroma patterns. New Zealand wines from the Marlborough region as well as the Australian ones from Victoria were grouped together based on the volatile composition. Wines from South Australia region formed one discrete class. Seven analytes, most of them esters, were found to be the relevant chemical compounds that characterized the classes. The grouping information obtained by GC-MS, was used to train metal oxide based electronic (MOS-Enose) and mass spectrometry based electronic (MS-Enose) noses. The combined use of solid phase microextraction (SPME) and ethanol removal prior to MOS-Enose analysis, allowed an average error of prediction of the regional origins of Sauvignon Blanc wines of 6.5% compared to 24% when static headspace (SHS) was employed. For MS-Enose, the misclassification rate was higher probably due to the requirement to delimit the m/z range considered.

  11. Analysis of volatile flavor compounds influencing Chinese-type soy sauces using GC-MS combined with HS-SPME and discrimination with electronic nose.

    Science.gov (United States)

    Gao, Lihua; Liu, Ting; An, Xinjing; Zhang, Jinlan; Ma, Xiaoran; Cui, Jinmei

    2017-01-01

    Soy sauce contains a variety of volatiles that are highly valuable to its quality with regard to sensory characteristics. This paper describes the analysis of volatile compounds influencing the flavor quality of Chinese-type soy sauces. Gas chromatography-mass spectrometry (GC-MS) combined with headspace-solid phase microextraction and electronic nose (E-nose) were applied for identifying the volatile flavor compounds as well as determining their volatile profiles of 12 soy sauces manufactured by different fermentation process. Forty one key volatile components of these 12 soy sauce products, a pure soy sauce and an acid-hydrolyzed vegetable protein sample, were compared in semi-quantitative form, and their volatile flavor profiles were analyzed by E-nose. The substantially similar results between hierarchical cluster analysis based on GC-MS data and E-nose analysis suggested that both techniques may be useful in evaluating the flavor quality of soy sauces and differentiating soy sauce products. The study also showed that there were less volatile flavor compounds in soy sauces produced through low-salt solid-state fermentation process, a traditional manufacturing technology and a widely adopted technology in Chinese soy sauce industries. In addition, the investigation suggested that the flavor quality of soy sauce varied widely in Chinese domestic market, and that the present Chinese national standards of soy sauce should be further perfected by the addition of flavor grades of soy sauce in the physical and chemical index. Meanwhile, this research provided valuable information to manufacturers and government regulators, which have practical significance to improve quality of soy sauces.

  12. Molecular modeling of polymer composite-analyte interactions in electronic nose sensors

    Science.gov (United States)

    Shevade, A. V.; Ryan, M. A.; Homer, M. L.; Manfreda, A. M.; Zhou, H.; Manatt, K. S.

    2003-01-01

    We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL electronic nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereoisomerism and sequence isomerism, while the CB is modeled as uncharged naphthalene rings with no hydrogens. The Dreiding 2.21 force field is used for the polymer, solvent molecules and graphite parameters are assigned to the carbon black atoms. A combination of molecular mechanics (MM) and molecular dynamics (NPT-MD and NVT-MD) techniques are used to obtain the equilibrium composite structure by inserting naphthalene rings in the polymer matrix. Polymers considered for this work include poly(4-vinylphenol), polyethylene oxide, and ethyl cellulose. Analytes studied are representative of both inorganic and organic compounds. The results are analyzed for the composite microstructure by calculating the radial distribution profiles as well as for the sensor response by predicting the interaction energies of the analytes with the composites. c2003 Elsevier Science B.V. All rights reserved.

  13. Early detection of fungal contamination on green coffee by a MOX sensors based Electronic Nose

    International Nuclear Information System (INIS)

    Sberveglieri, V.; Pulvirenti, A.; Fava, P.; Concina, I.; Falasconi, M.; Gobbi, E.

    2011-01-01

    Fungal growth can occur on green coffee beans along all the distribution chain, eventually bringing on health hazards to consumers, because of the production of toxic metabolites (mycotoxins). Besides, the sensorial contamination due to volatiles by-products of fungal metabolism could cause defects on coffee also after roasting. Therefore, it is necessary to devise strategies to detect and quantify fungal infection and toxin production at early stages of the food chain. One of the most promising techniques is the analysis of volatile compounds in the headspace gas surrounding the samples. The aim of this work was to verify the ability of the Electronic Nose (EN EOS 835 ) to early detect the microbial contamination of Arabica green coffee. This EN is equipped with Metal Oxide Semiconductor sensor array. Gas chromatography coupled to mass spectrometry (GC-MS) analysis of the static headspace of non-contaminated Arabica green coffee samples was carried out to confirm the EN ability to provide satisfactory indications about the presence of contamination.

  14. Identification by microscopy and MS-based electronic nose of a fraudulent addition to maize gluten

    Directory of Open Access Journals (Sweden)

    Frick G.

    2009-01-01

    Full Text Available Classical and chemometric methods have been used to detect falsified maize gluten products. Microscopic observations (numerous starch grains, seed envelopes and wheat bran fragments clearly showed the presence of atypical maize gluten particles in samples with otherwise normal crude protein levels (≥ 60% and the usual gold-yellow color. Chemical analyses in a few samples confirmed the presence of urea (19 to 174 g.kg-1, melamine (0 to 20 g.kg-1, and cyanuric acid (0 to 10 g.kg-1 coping for the low levels of methionine (0 to 13 g.kg-1 in incriminated products (genuine maize gluten methionine level ≥ 16 g.kg-1. Furthermore, a fast technique (an electronic nose based on mass spectrometry detection also proved to be reliable for the identification of falsified maize gluten products: 100% correct classification of model and unknown samples was achieved with principal component analysis. As a consequence of these results, the Swiss feed-inspection authority blocked the import, or restricted the use, of 2,500 tons of the falsified products.

  15. The JPL Electronic Nose: Monitoring Air in the US Lab on the International Space Station

    Science.gov (United States)

    Ryan, M. A.; Manatt, K. S.; Gluck, S.; Shevade, A. V.; Kisor, A. K.; Zhou, H.; Lara, L. M.; Homer, M. L.

    2010-01-01

    An electronic nose with a sensor array of 32 conductometric sensors has been developed at the Jet Propulsion Laboratory (JPL) to monitor breathing air in spacecraft habitat. The Third Generation ENose is designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 oC, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The monitoring targets are anomalous events such as leaks and spills of solvents, coolants or other fluids. The JPL ENose operated as a technology demonstration for seven months in the U.S. Laboratory Destiny during 2008-2009. Analysis of ENose monitoring data shows that there was regular, periodic rise and fall of humidity and occasional releases of Freon 218 (perfluoropropane), formaldehyde, methanol and ethanol. There were also several events of unknown origin, half of them from the same source. Each event lasted from 20 to 100 minutes, consistent with the air replacement time in the US Lab.

  16. Analyzing the flavor compounds in Chinese traditional fermented shrimp pastes by HS-SPME-GC/MS and electronic nose

    Science.gov (United States)

    Fan, Yan; Yin, Li'ang; Xue, Yong; Li, Zhaojie; Hou, Hu; Xue, Changhu

    2017-04-01

    Shrimp paste is a type of condiments with high nutritional value. However, the flavors of shrimp paste, particularly the non-uniformity flavors, have limited its application in food processing. In order to identify the characteristic flavor compounds in Chinese traditional shrimp pastes, five kinds of typical commercial products were evaluated in this study. The differences in the volatile composition of the five products were investigated. Solid phase micro-extraction method was employed to extract the volatile compounds. GC-MS and electronic nose were applied to identify the compounds, and the data were analyzed using principal component analysis (PCA). A total of 62 volatile compounds were identified, including 8 alcohols, 7 aldehydes, 3 ketones, 7 ethers, 7 acids, 3 esters, 6 hydrocarbons, 12 pyrazines, 2 phenols, and 7 other compounds. The typical volatile compounds contributing to the flavor of shrimp paste were found as follows: dimethyl disulfide, dimethyl tetrasulfide, dimethyl trisulfide, 2, 3, 5-trimethyl-6-ethyl pyrazine, ethyl-2, 5-dimethyl-pyrazine, phenol and indole. Propanoic acid, butanoic acid, furans, and 2-hydroxy-3-pentanone caused unpleasant odors, such as pungent and rancid odors. Principal component analysis showed that the content of volatile compounds varied depending on the processing conditions and shrimp species. These results indicated that the combinations of multiple analysis and identification methods could make up the limitations of a single method, enhance the accuracy of identification, and provide useful information for sensory research and product development.

  17. Biofiltration of composting gases using different municipal solid waste-pruning residue composts: monitoring by using an electronic nose.

    Science.gov (United States)

    López, R; Cabeza, I O; Giráldez, I; Díaz, M J

    2011-09-01

    The concentration of volatile organic compounds (VOCs) during the composting of kitchen waste and pruning residues, and the abatement of VOCs by different compost biofilters was studied. VOCs removal efficiencies greater than 90% were obtained using composts of municipal solid waste (MSW) or MSW-pruning residue as biofilter material. An electronic nose identified qualitative differences among the biofilter output gases at very low concentrations of VOCs. These differences were related to compost constituents, compost particle size (2-7 or 7-20mm), and a combination of both factors. The total concentration of VOCs determined by a photoionization analyser and inferred from electronic nose data sets were correlated over an ample range of concentrations of VOCs, showing that these techniques could be specially adapted for the monitoring of these processes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Close-To-Practice Assessment Of Meat Freshness With Metal Oxide Sensor Microarray Electronic Nose

    International Nuclear Information System (INIS)

    Musatov, V. Yu.; Sysoev, V. V.; Sommer, M.; Kiselev, I.

    2009-01-01

    In this report we estimate the ability of KAMINA e-nose, based on a metal oxide sensor (MOS) microarray and Linear Discriminant Analysis (LDA) pattern recognition, to evaluate meat freshness. The received results show that, 1) one or two exposures of standard meat samples to the e-nose are enough for the instrument to recognize the fresh meat prepared by the same supplier with 100% probability; 2) the meat samples of two kinds, stored at 4 deg. C and 25 deg. C, are mutually recognized at early stages of decay with the help of the LDA model built independently under the e-nose training to each kind of meat; 3) the 3-4 training cycles of exposure to meat from different suppliers are necessary for the e-nose to build a reliable LDA model accounting for the supplier factor. This study approves that the MOS e-nose is ready to be currently utilised in food industry for evaluation of product freshness. The e-nose performance is characterized by low training cost, a confident recognition power of various product decay conditions and easy adjustment to changing conditions.

  19. The Detection of Patients at Risk of Gastrointestinal Toxicity during Pelvic Radiotherapy by Electronic Nose and FAIMS: A Pilot Study

    Science.gov (United States)

    Covington, James A.; Wedlake, Linda; Andreyev, Jervoise; Ouaret, Nathalie; Thomas, Matthew G.; Nwokolo, Chuka U.; Bardhan, Karna D.; Arasaradnam, Ramesh P.

    2012-01-01

    It is well known that the electronic nose can be used to identify differences between human health and disease for a range of disorders. We present a pilot study to investigate if the electronic nose and a newer technology, FAIMS (Field Asymmetric Ion Mobility Spectrometry), can be used to identify and help inform the treatment pathway for patients receiving pelvic radiotherapy, which frequently causes gastrointestinal side-effects, severe in some. From a larger group, 23 radiotherapy patients were selected where half had the highest levels of toxicity and the others the lowest. Stool samples were obtained before and four weeks after radiotherapy and the volatiles and gases emitted analysed by both methods; these chemicals are products of fermentation caused by gut microflora. Principal component analysis of the electronic nose data and wavelet transform followed by Fisher discriminant analysis of FAIMS data indicated that it was possible to separate patients after treatment by their toxicity levels. More interestingly, differences were also identified in their pre-treatment samples. We believe these patterns arise from differences in gut microflora where some combinations of bacteria result to give this olfactory signature. In the future our approach may result in a technique that will help identify patients at “high risk” even before radiation treatment is started. PMID:23201982

  20. The Detection of Patients at Risk of Gastrointestinal Toxicity during Pelvic Radiotherapy by Electronic Nose and FAIMS: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Ramesh P. Arasaradnam

    2012-09-01

    Full Text Available It is well known that the electronic nose can be used to identify differences between human health and disease for a range of disorders. We present a pilot study to investigate if the electronic nose and a newer technology, FAIMS (Field Asymmetric Ion Mobility Spectrometry, can be used to identify and help inform the treatment pathway for patients receiving pelvic radiotherapy, which frequently causes gastrointestinal side-effects, severe in some. From a larger group, 23 radiotherapy patients were selected where half had the highest levels of toxicity and the others the lowest. Stool samples were obtained before and four weeks after radiotherapy and the volatiles and gases emitted analysed by both methods; these chemicals are products of fermentation caused by gut microflora. Principal component analysis of the electronic nose data and wavelet transform followed by Fisher discriminant analysis of FAIMS data indicated that it was possible to separate patients after treatment by their toxicity levels. More interestingly, differences were also identified in their pre-treatment samples. We believe these patterns arise from differences in gut microflora where some combinations of bacteria result to give this olfactory signature. In the future our approach may result in a technique that will help identify patients at “high risk” even before radiation treatment is started.

  1. Application of multi-way analysis to UV-visible spectroscopy, gas chromatography and electronic nose data for wine ageing evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Prieto, N. [Department of Condensed Matter Physics, Faculty of Sciences, University of Valladolid, 47011 Valladolid (Spain); Department of Inorganic Chemistry, Escuela de Ingenierias Industriales, University of Valladolid, Paseo del Cauce, 59, 47011 Valladolid (Spain); Rodriguez-Mendez, M.L. [Department of Inorganic Chemistry, Escuela de Ingenierias Industriales, University of Valladolid, Paseo del Cauce, 59, 47011 Valladolid (Spain); Leardi, R. [Department of Pharmaceutical and Food Chemistry and Technology, University of Genoa, Via Brigata Salerno 13, I-16147 8 Genoa (Italy); Oliveri, P., E-mail: oliveri@dictfa.unige.it [Department of Pharmaceutical and Food Chemistry and Technology, University of Genoa, Via Brigata Salerno 13, I-16147 8 Genoa (Italy); Hernando-Esquisabel, D.; Iniguez-Crespo, M. [Gobierno de la Rioja, Consejeria de Agricultura y Alimentacion, Estacion Enologica, Breton de los Herreros 4, 26200 Haro, La Rioja (Spain); Saja, J.A. de [Department of Condensed Matter Physics, Faculty of Sciences, University of Valladolid, 47011 Valladolid (Spain)

    2012-03-16

    Highlights: Black-Right-Pointing-Pointer Wine samples were analytically characterised according to their ageing process. Black-Right-Pointing-Pointer Signals from a sensor-based electronic nose were fused with GC-MS and UV-visible data. Black-Right-Pointing-Pointer The study involved 6 periodical determinations of 20 variables on 6 different wines. Black-Right-Pointing-Pointer Multi-way analysis allowed to efficiently extract the maximum information from data. Black-Right-Pointing-Pointer Multi-way methods represent the most suitable tool for processing three-mode data. - Abstract: In this study, a multi-way method (Tucker3) was applied to evaluate the performance of an electronic nose for following the ageing of red wines. The odour evaluation carried out with the electronic nose was combined with the quantitative analysis of volatile composition performed by GC-MS, and colour characterisation by UV-visible spectroscopy. Thanks to Tucker3, it was possible to understand connections among data obtained from these three different systems and to estimate the effect of different sources of variability on wine evaluation. In particular, the application of Tucker3 supplied a global visualisation of data structure, which was very informative to understand relationships between sensors responses and chemical composition of wines. The results obtained indicate that the analytical methods employed are useful tools to follow the wine ageing process, to differentiate wine samples according to ageing type (either in barrel or in stainless steel tanks with the addition of small oak wood pieces) and to the origin (French or American) of the oak wood. Finally, it was possible to designate the volatile compounds which play a major role in such a characterisation.

  2. Application of multi-way analysis to UV–visible spectroscopy, gas chromatography and electronic nose data for wine ageing evaluation

    International Nuclear Information System (INIS)

    Prieto, N.; Rodriguez-Méndez, M.L.; Leardi, R.; Oliveri, P.; Hernando-Esquisabel, D.; Iñiguez-Crespo, M.; Saja, J.A. de

    2012-01-01

    Highlights: ► Wine samples were analytically characterised according to their ageing process. ► Signals from a sensor-based electronic nose were fused with GC–MS and UV–visible data. ► The study involved 6 periodical determinations of 20 variables on 6 different wines. ► Multi-way analysis allowed to efficiently extract the maximum information from data. ► Multi-way methods represent the most suitable tool for processing three-mode data. - Abstract: In this study, a multi-way method (Tucker3) was applied to evaluate the performance of an electronic nose for following the ageing of red wines. The odour evaluation carried out with the electronic nose was combined with the quantitative analysis of volatile composition performed by GC–MS, and colour characterisation by UV–visible spectroscopy. Thanks to Tucker3, it was possible to understand connections among data obtained from these three different systems and to estimate the effect of different sources of variability on wine evaluation. In particular, the application of Tucker3 supplied a global visualisation of data structure, which was very informative to understand relationships between sensors responses and chemical composition of wines. The results obtained indicate that the analytical methods employed are useful tools to follow the wine ageing process, to differentiate wine samples according to ageing type (either in barrel or in stainless steel tanks with the addition of small oak wood pieces) and to the origin (French or American) of the oak wood. Finally, it was possible to designate the volatile compounds which play a major role in such a characterisation.

  3. Detection and quantification of ochratoxin A and deoxynivalenol in barley grains by GC-MS and electronic nose.

    Science.gov (United States)

    Olsson, J; Börjesson, T; Lundstedt, T; Schnürer, J

    2002-02-05

    Mycotoxin contamination of cereal grains can be detected and quantified using complex extraction procedures and analytical techniques. Normally, the grain odour, i.e. the presence of non-grain volatile metabolites, is used for quality classification of grain. We have investigated the possibility of using fungal volatile metabolites as indicators of mycotoxins in grain. Ten barley samples with normal odour, and 30 with some kind of off-odour were selected from Swedish granaries. The samples were evaluated with regard to moisture content, fungal contamination, ergosterol content, and levels of ochratoxin A (OA) and deoxynivalenol (DON). Volatile compounds were also analysed using both an electronic nose and gas chromatography combined with mass spectrometry (GC-MS). Samples with normal odour had no detectable ochratoxin A and average DON contents of 16 microg kg(-1) (range 0-80), while samples with off-odour had average OA contents of 76 microg kg(-1) (range 0-934) and DON contents of 69 microg kg(-1) (range 0-857). Data were evaluated by multivariate data analysis using projection methods such as principal component analysis (PCA) and partial least squares (PLS). The results show that it was possible to classify the OA level as below or above the maximum limit of 5 microg kg(-1) cereal grain established by the Swedish National Food Administration, and that the DON level could be estimated using PLS. Samples with OA levels below 5 microg kg(-1) had higher concentration of aldehydes (nonanal, 2-hexenal) and alcohols (1-penten-3-ol, 1-octanol). Samples with OA levels above 5 microg kg(-1) had higher concentrations of ketones (2-hexanone, 3-octanone). The GC-MS system predicted OA concentrations with a higher accuracy than the electronic nose, since the GC-MS misclassified only 3 of 37 samples and the electronic nose 7 of 37 samples. No correlation was found between odour and OA level, as samples with pronounced or strong off-odours had OA levels both below and above 5

  4. Development of Electronic Nose and Near Infrared Spectroscopy Analysis Techniques to Monitor the Critical Time in SSF Process of Feed Protein

    Directory of Open Access Journals (Sweden)

    Hui Jiang

    2014-10-01

    Full Text Available In order to assure the consistency of the final product quality, a fast and effective process monitoring is a growing need in solid state fermentation (SSF industry. This work investigated the potential of non-invasive techniques combined with the chemometrics method, to monitor time-related changes that occur during SSF process of feed protein. Four fermentation trials conducted were monitored by an electronic nose device and a near infrared spectroscopy (NIRS spectrometer. Firstly, principal component analysis (PCA and independent component analysis (ICA were respectively applied to the feature extraction and information fusion. Then, the BP_AdaBoost algorithm was used to develop the fused model for monitoring of the critical time in SSF process of feed protein. Experimental results showed that the identified results of the fusion model are much better than those of the single technique model both in the training and validation sets, and the complexity of the fusion model was also less than that of the single technique model. The overall results demonstrate that it has a high potential in online monitoring of the critical moment in SSF process by use of integrating electronic nose and NIRS techniques, and data fusion from multi-technique could significantly improve the monitoring performance of SSF process.

  5. Application of multi-way analysis to UV-visible spectroscopy, gas chromatography and electronic nose data for wine ageing evaluation.

    Science.gov (United States)

    Prieto, N; Rodriguez-Méndez, M L; Leardi, R; Oliveri, P; Hernando-Esquisabel, D; Iñiguez-Crespo, M; de Saja, J A

    2012-03-16

    In this study, a multi-way method (Tucker3) was applied to evaluate the performance of an electronic nose for following the ageing of red wines. The odour evaluation carried out with the electronic nose was combined with the quantitative analysis of volatile composition performed by GC-MS, and colour characterisation by UV-visible spectroscopy. Thanks to Tucker3, it was possible to understand connections among data obtained from these three different systems and to estimate the effect of different sources of variability on wine evaluation. In particular, the application of Tucker3 supplied a global visualisation of data structure, which was very informative to understand relationships between sensors responses and chemical composition of wines. The results obtained indicate that the analytical methods employed are useful tools to follow the wine ageing process, to differentiate wine samples according to ageing type (either in barrel or in stainless steel tanks with the addition of small oak wood pieces) and to the origin (French or American) of the oak wood. Finally, it was possible to designate the volatile compounds which play a major role in such a characterisation. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Early detection of fungal growth in bakery products by use of an electronic nose based on mass spectrometry.

    Science.gov (United States)

    Vinaixa, Maria; Marín, Sonia; Brezmes, Jesús; Llobet, Eduard; Vilanova, Xavier; Correig, Xavier; Ramos, Antonio; Sanchis, Vicent

    2004-10-06

    This paper presents the design, optimization, and evaluation of a mass spectrometry-based electronic nose (MS e-nose) for early detection of unwanted fungal growth in bakery products. Seven fungal species (Aspergillus flavus, Aspergillus niger, Eurotium amstelodami, Eurotium herbariorum, Eurotium rubrum, Eurotium repens, and Penicillium corylophillum) were isolated from bakery products and used for the study. Two sampling headspace techniques were tested: static headspace (SH) and solid-phase microextraction (SPME). Cross-validated models based on principal component analysis (PCA), coupled to discriminant function analysis (DFA) and fuzzy ARTMAP, were used as data treatment. When attempting to discriminate between inoculated and blank control vials or between genera or species of in vitro growing cultures, sampling based on SPME showed better results than those based on static headspace. The SPME-MS-based e-nose was able to predict fungal growth with 88% success after 24 h of inoculation and 98% success after 48 h when changes were monitored in the headspace of fungal cultures growing on bakery product analogues. Prediction of the right fungal genus reached 78% and 88% after 24 and 96 h, respectively.

  7. A Low Noise CMOS Readout Based on a Polymer-Coated SAW Array for Miniature Electronic Nose

    Directory of Open Access Journals (Sweden)

    Cheng-Chun Wu

    2016-10-01

    Full Text Available An electronic nose (E-Nose is one of the applications for surface acoustic wave (SAW sensors. In this paper, we present a low-noise complementary metal–oxide–semiconductor (CMOS readout application-specific integrated circuit (ASIC based on an SAW sensor array for achieving a miniature E-Nose. The center frequency of the SAW sensors was measured to be approximately 114 MHz. Because of interference between the sensors, we designed a low-noise CMOS frequency readout circuit to enable the SAW sensor to obtain frequency variation. The proposed circuit was fabricated in Taiwan Semiconductor Manufacturing Company (TSMC 0.18 μm 1P6M CMOS process technology. The total chip size was nearly 1203 × 1203 μm2. The chip was operated at a supply voltage of 1 V for a digital circuit and 1.8 V for an analog circuit. The least measurable difference between frequencies was 4 Hz. The detection limit of the system, when estimated using methanol and ethanol, was 0.1 ppm. Their linearity was in the range of 0.1 to 26,000 ppm. The power consumption levels of the analog and digital circuits were 1.742 mW and 761 μW, respectively.

  8. Chocolate Classification by an Electronic Nose with Pressure Controlled Generated Stimulation.

    Science.gov (United States)

    Valdez, Luis F; Gutiérrez, Juan Manuel

    2016-10-20

    In this work, we will analyze the response of a Metal Oxide Gas Sensor (MOGS) array to a flow controlled stimulus generated in a pressure controlled canister produced by a homemade olfactometer to build an E-nose. The built E-nose is capable of chocolate identification between the 26 analyzed chocolate bar samples and four features recognition (chocolate type, extra ingredient, sweetener and expiration date status). The data analysis tools used were Principal Components Analysis (PCA) and Artificial Neural Networks (ANNs). The chocolate identification E-nose average classification rate was of 81.3% with 0.99 accuracy (Acc), 0.86 precision (Prc), 0.84 sensitivity (Sen) and 0.99 specificity (Spe) for test. The chocolate feature recognition E-nose gives a classification rate of 85.36% with 0.96 Acc, 0.86 Prc, 0.85 Sen and 0.96 Spe. In addition, a preliminary sample aging analysis was made. The results prove the pressure controlled generated stimulus is reliable for this type of studies.

  9. Chocolate Classification by an Electronic Nose with Pressure Controlled Generated Stimulation

    Directory of Open Access Journals (Sweden)

    Luis F. Valdez

    2016-10-01

    Full Text Available In this work, we will analyze the response of a Metal Oxide Gas Sensor (MOGS array to a flow controlled stimulus generated in a pressure controlled canister produced by a homemade olfactometer to build an E-nose. The built E-nose is capable of chocolate identification between the 26 analyzed chocolate bar samples and four features recognition (chocolate type, extra ingredient, sweetener and expiration date status. The data analysis tools used were Principal Components Analysis (PCA and Artificial Neural Networks (ANNs. The chocolate identification E-nose average classification rate was of 81.3% with 0.99 accuracy (Acc, 0.86 precision (Prc, 0.84 sensitivity (Sen and 0.99 specificity (Spe for test. The chocolate feature recognition E-nose gives a classification rate of 85.36% with 0.96 Acc, 0.86 Prc, 0.85 Sen and 0.96 Spe. In addition, a preliminary sample aging analysis was made. The results prove the pressure controlled generated stimulus is reliable for this type of studies.

  10. Abductive networks applied to electronic combat

    Science.gov (United States)

    Montgomery, Gerard J.; Hess, Paul; Hwang, Jong S.

    1990-08-01

    A practical approach to dealing with combinatorial decision problems and uncertainties associated with electronic combat through the use of networks of high-level functional elements called abductive networks is presented. It describes the application of the Abductory Induction Mechanism (AIMTM) a supervised inductive learning tool for synthesizing polynomial abductive networks to the electronic combat problem domain. From databases of historical expert-generated or simulated combat engagements AIM can often induce compact and robust network models for making effective real-time electronic combat decisions despite significant uncertainties or a combinatorial explosion of possible situations. The feasibility of applying abductive networks to realize advanced combat decision aiding capabilities was demonstrated by applying AIM to a set of electronic combat simulations. The networks synthesized by AIM generated accurate assessments of the intent lethality and overall risk associated with a variety of simulated threats and produced reasonable estimates of the expected effectiveness of a group of electronic countermeasures for a large number of simulated combat scenarios. This paper presents the application of abductive networks to electronic combat summarizes the results of experiments performed using AIM discusses the benefits and limitations of applying abductive networks to electronic combat and indicates why abductive networks can often result in capabilities not attainable using alternative approaches. 1. ELECTRONIC COMBAT. UNCERTAINTY. AND MACHINE LEARNING Electronic combat has become an essential part of the ability to make war and has become increasingly complex since

  11. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose.

    Science.gov (United States)

    Esfahani, Siavash; Sagar, Nidhi M; Kyrou, Ioannis; Mozdiak, Ella; O'Connell, Nicola; Nwokolo, Chuka; Bardhan, Karna D; Arasaradnam, Ramesh P; Covington, James A

    2016-01-25

    The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose--an instrument designed to replicate the biological olfactory system. Of the possible biological media available to "sniff", urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at -80 °C. Here we investigated the effect of storage time (years) on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at -80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry--a type of electronic nose). It was discovered that gas emissions (concentration and diversity) reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life.

  12. Classification of Tempranillo wines according to geographic origin: Combination of mass spectrometry based electronic nose and chemometrics

    Energy Technology Data Exchange (ETDEWEB)

    Cynkar, Wies, E-mail: wies.cynkar@awri.com.au [Australian Wine Research Institute, PO Box 197, Glen Osmond, SA 5064 (Australia); Dambergs, Robert [Australian Wine Research Institute, Tasmanian Institute of Agricultural Research, University of Tasmania, Private Bag 98, Hobart Tasmania 7001 (Australia); Smith, Paul; Cozzolino, Daniel [Australian Wine Research Institute, PO Box 197, Glen Osmond, SA 5064 (Australia)

    2010-02-15

    Rapid methods employing instruments such as electronic noses (EN) or gas sensors are used in the food and beverage industries to monitor and assess the composition and quality of products. Similar to other food industries, the wine industry has a clear need for simple, rapid and cost effective techniques for objectively evaluating the quality of grapes, wine and spirits. In this study a mass spectrometry based electronic nose (MS-EN) instrument combined with chemometrics was used to predict the geographical origin of Tempranillo wines produced in Australia and Spain. The MS-EN data generated were analyzed using principal components analysis (PCA), partial least squares discriminant analysis (PLS-DA) and stepwise linear discriminant analysis (SLDA) with full cross validation (leave-one-out method). The SLDA classified correctly 86% of the samples while PLS-DA 85% of Tempranillo wines according to their geographical origin. The relative benefits of using MS-EN will provide capability for rapid screening of wines. However, this technique does not provide the identification and quantitative determination of individual compounds responsible for the different aroma notes in the wine.

  13. Both gas chromatography and an electronic nose reflect chemical polymorphism of juniper shrubs browsed or avoided by sheep.

    Science.gov (United States)

    Markó, Gábor; Novák, Ildikó; Bernáth, Jeno; Altbäcker, Vilmos

    2011-07-01

    Chemical polymorphism may contribute to variation in browsing damage by mammalian herbivores. Earlier, we demonstrated that essential oil concentration in juniper, Juniperus communis, was negatively associated with herbivore browsing. The aim of the present study was to characterize the volatile chemical composition of browsed and non-browsed J. communis. By using either gas chromatography with flame ionization detection (GC-FID) or an electronic nose device, we could separate sheep-browsed or non-browsed juniper shrubs by their essential oil pattern and complex odor matrix. The main components of the essential oil from J. communis were monoterpenes. We distinguished three chemotypes, dominated either by α-pinene, sabinene, or δ-3-carene. Shrubs belonging to the α-pinene- or sabinene-dominated groups were browsed, whereas all individuals with the δ-3-carene chemotype were unused by the local herbivores. The electronic nose also separated the browsed and non-browsed shrubs indicating that their odor matrix could guide sheep browsing. Responses of sheep could integrate the post-ingestive effects of plant secondary metabolites with sensory experience that stems from odor-phytotoxin interactions. Chemotype diversity could increase the survival rate in the present population of J. communis as certain shrubs could benefit from relatively better chemical protection against the herbivores.

  14. Classification of Tempranillo wines according to geographic origin: Combination of mass spectrometry based electronic nose and chemometrics

    International Nuclear Information System (INIS)

    Cynkar, Wies; Dambergs, Robert; Smith, Paul; Cozzolino, Daniel

    2010-01-01

    Rapid methods employing instruments such as electronic noses (EN) or gas sensors are used in the food and beverage industries to monitor and assess the composition and quality of products. Similar to other food industries, the wine industry has a clear need for simple, rapid and cost effective techniques for objectively evaluating the quality of grapes, wine and spirits. In this study a mass spectrometry based electronic nose (MS-EN) instrument combined with chemometrics was used to predict the geographical origin of Tempranillo wines produced in Australia and Spain. The MS-EN data generated were analyzed using principal components analysis (PCA), partial least squares discriminant analysis (PLS-DA) and stepwise linear discriminant analysis (SLDA) with full cross validation (leave-one-out method). The SLDA classified correctly 86% of the samples while PLS-DA 85% of Tempranillo wines according to their geographical origin. The relative benefits of using MS-EN will provide capability for rapid screening of wines. However, this technique does not provide the identification and quantitative determination of individual compounds responsible for the different aroma notes in the wine.

  15. Discrimination of volatiles of refined and whole wheat bread containing red and white wheat bran using an electronic nose.

    Science.gov (United States)

    Sapirstein, Harry D; Siddhu, Silvi; Aliani, Michel

    2012-11-01

    The principal objective of this study was to evaluate the capability of electronic (E) nose technology to discriminate refined and whole wheat bread made with white or red wheat bran according to their headspace volatiles. Whole wheat flour was formulated with a common refined flour from hard red spring wheat, blended at the 15% replacement level with bran milled from representative samples of one hard red and 2 hard white wheats. A commercial formula was used for breadmaking. Results varied according to the nature of the sample, that is, crust, crumb, or whole slices. Bread crust and crumb were completely discriminated. Crumb of whole wheat bread made with red bran was distinct from other bread types. When misclassified, whole wheat bread crumb with white bran was almost invariably identified as refined flour bread crumb. Using crust as the basis for comparisons, the largest difference in volatiles was between refined flour bread and whole wheat bread as a group. When refined flour bread crust was misclassified, samples tended to be confused with whole white wheat crust. Samples prepared from whole bread slices were poorly discriminated in general. E-nose results indicated that whole wheat bread formulated with white bran was more similar in volatile makeup to refined flour bread compared to whole wheat bread made with red bran. The E-nose appears to be very capable to accommodate differentiation of bread volatiles whose composition varies due to differences in flour or bran type. Consumer preference of bread made using refined flour in contrast to whole wheat flour is partly due to the different aroma of whole wheat bread. This study used an electronic nose to analyze bread volatiles, and showed that whole wheat bread incorporating white bran was different from counterpart bread made using red bran, and was closer in volatile makeup to "white" bread made without bran. Commercial millers and bakers can take advantage of these results to formulate whole wheat flour

  16. A Wireless and Portable Electronic Nose to Differentiate Musts of Different Ripeness Degree and Grape Varieties

    Directory of Open Access Journals (Sweden)

    Manuel Aleixandre

    2015-04-01

    Full Text Available Two novel applications using a portable and wireless sensor system (e-nose for the wine producing industry—The recognition and classification of musts coming from different grape ripening times and from different grape varieties—Are reported in this paper. These applications are very interesting because a lot of varieties of grapes produce musts with low and similar aromatic intensities so they are very difficult to distinguish using a sensory panel. Therefore the system could be used to monitor the ripening evolution of the different types of grapes and to assess some useful characteristics, such as the identification of the grape variety origin and to prediction of the wine quality. Ripening grade of collected samples have been also evaluated by classical analytical techniques, measuring physicochemical parameters, such as, pH, Brix, Total Acidity (TA and Probable Grade Alcoholic (PGA. The measurements were carried out for two different harvests, using different red (Barbera, Petit Verdot, Tempranillo, and Touriga and white (Malvar, Malvasía, Chenin Blanc, and Sauvignon Blanc grape musts coming from the experimental cellar of the IMIDRA at Madrid. Principal Component Analysis (PCA and Probabilistic Neural Networks (PNN have been used to analyse the obtained data by e-nose. In addition, and the Canonical Correlation Analysis (CCA method has been carried out to correlate the results obtained by both technologies.

  17. Non-destructive flavour evaluation of red onion (Allium cepa L.) ecotypes: an electronic-nose-based approach.

    Science.gov (United States)

    Russo, Mariateresa; di Sanzo, Rosa; Cefaly, Vittoria; Carabetta, Sonia; Serra, Demetrio; Fuda, Salvatore

    2013-11-15

    This work reports preliminary results on the potential of a metal oxide sensor (MOS)-based electronic nose, as a non-destructive method to discriminate three "Tropea Red Onion" PGI ecotypes (TrT, TrMC and TrA) from each other and the common red onion (RO), which is usually used to counterfeit. The signals from the sensor array were processed using a canonical discriminant function analysis (DFA) pattern recognition technique. The DFA on onion samples showed a clear separation among the four onion groups with an overall correct classification rate (CR) of 97.5%. Onion flavour is closely linked to pungency and thus to the pyruvic acid content. The e-nose analysis results are in good agreement with pyruvic acid analysis. This work demonstrated that artificial olfactory systems have potential for use as an innovative, rapid and specific non-destructive technique, and may provide a method to protect food products against counterfeiting. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Evaluation of coffee roasting degree by using electronic nose and artificial neural network for off-line quality control.

    Science.gov (United States)

    Romani, Santina; Cevoli, Chiara; Fabbri, Angelo; Alessandrini, Laura; Dalla Rosa, Marco

    2012-09-01

    An electronic nose (EN) based on an array of 10 metal oxide semiconductor sensors was used, jointly with an artificial neural network (ANN), to predict coffee roasting degree. The flavor release evolution and the main physicochemical modifications (weight loss, density, moisture content, and surface color: L*, a*), during the roasting process of coffee, were monitored at different cooking times (0, 6, 8, 10, 14, 19 min). Principal component analysis (PCA) was used to reduce the dimensionality of sensors data set (600 values per sensor). The selected PCs were used as ANN input variables. Two types of ANN methods (multilayer perceptron [MLP] and general regression neural network [GRNN]) were used in order to estimate the EN signals. For both neural networks the input values were represented by scores of sensors data set PCs, while the output values were the quality parameter at different roasting times. Both the ANNs were able to well predict coffee roasting degree, giving good prediction results for both roasting time and coffee quality parameters. In particular, GRNN showed the highest prediction reliability. Actually the evaluation of coffee roasting degree is mainly a manned operation, substantially based on the empirical final color observation. For this reason it requires well-trained operators with a long professional skill. The coupling of e-nose and artificial neural networks (ANNs) may represent an effective possibility to roasting process automation and to set up a more reproducible procedure for final coffee bean quality characterization. © 2012 Institute of Food Technologists®

  19. SU-F-T-81: Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, L; Fan, J; Eldib, A; Price, R; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Treating nose skin with an electron beam is of a substantial challenge due to uneven nose surfaces and tissue heterogeneity, and consequently could have a great uncertainty of dose accuracy on the target. This work explored the method using Monte Carlo (MC)-based energy and intensity modulated electron radiotherapy (MERT), which would be delivered with a photon MLC in a standard medical linac (Artiste). Methods: The traditional treatment on the nose skin involves the usage of a bolus, often with a single energy electron beam. This work avoided using the bolus, and utilized mixed energies of electron beams. An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. A clinical case of the nose skin, which was previously treated with a single 9 MeV electron beam, was replanned with the MERT method. The resultant dose distributions were compared with the plan previously clinically used. The dose volume histogram of the MERT plan is calculated to examine the coverage of the planning target volume (PTV) and critical structure doses. Results: The target coverage and conformality in the MERT plan are improved as compared to the conventional plan. The MERT can provide more sufficient target coverage and less normal tissue dose underneath the nose skin. Conclusion: Compared to the conventional treatment technique, using MERT for the nose skin treatment has shown the dosimetric advantages in the PTV coverage and conformality. In addition, this technique eliminates the necessity of the cutout and bolus, which makes the treatment more efficient and accurate.

  20. Improved algorithms for the classification of rough rice using a bionic electronic nose based on PCA and the Wilks distribution.

    Science.gov (United States)

    Xu, Sai; Zhou, Zhiyan; Lu, Huazhong; Luo, Xiwen; Lan, Yubin

    2014-03-19

    Principal Component Analysis (PCA) is one of the main methods used for electronic nose pattern recognition. However, poor classification performance is common in classification and recognition when using regular PCA. This paper aims to improve the classification performance of regular PCA based on the existing Wilks Λ-statistic (i.e., combined PCA with the Wilks distribution). The improved algorithms, which combine regular PCA with the Wilks Λ-statistic, were developed after analysing the functionality and defects of PCA. Verification tests were conducted using a PEN3 electronic nose. The collected samples consisted of the volatiles of six varieties of rough rice (Zhongxiang1, Xiangwan13, Yaopingxiang, WufengyouT025, Pin 36, and Youyou122), grown in same area and season. The first two principal components used as analysis vectors cannot perform the rough rice varieties classification task based on a regular PCA. Using the improved algorithms, which combine the regular PCA with the Wilks Λ-statistic, many different principal components were selected as analysis vectors. The set of data points of the Mahalanobis distance between each of the varieties of rough rice was selected to estimate the performance of the classification. The result illustrates that the rough rice varieties classification task is achieved well using the improved algorithm. A Probabilistic Neural Networks (PNN) was also established to test the effectiveness of the improved algorithms. The first two principal components (namely PC1 and PC2) and the first and fifth principal component (namely PC1 and PC5) were selected as the inputs of PNN for the classification of the six rough rice varieties. The results indicate that the classification accuracy based on the improved algorithm was improved by 6.67% compared to the results of the regular method. These results prove the effectiveness of using the Wilks Λ-statistic to improve the classification accuracy of the regular PCA approach. The results

  1. Characterization of Volatile Compounds in Chilled Cod (Gadus morhua) fillets by gas chromatography and detection of quality indicators by an electronic nose

    NARCIS (Netherlands)

    Olafsdottir, G.; Jonsdottir, R.; Lauzon, H.L.; Luten, J.B.; Kristbergsson, K.

    2005-01-01

    Volatile compounds in cod fillets packed in Styrofoam boxes were analyzed during chilled storage (0.5 C) by gas chromatography (GC)-mass spectrometry and GC-olfactometry to screen potential quality indicators present in concentrations high enough for detection by an electronic nose. Photobacterium

  2. ANP applied to electronics engineering project selection

    International Nuclear Information System (INIS)

    Habib, M.

    2010-01-01

    Project selection in Electronics engineering is a complex decision-making process. This research paper illustrates an application of ANP/AHP process. The AHP (Analytic Hierarchy Process) is employed to break down large unstructured decision problems into manageable and measureable components. The ANP, as the general form of AHP, is powerful to deal with complex decisions where interdependence exists in a decision model. The research paper discusses the use of the ANP, a general form of Saaty's analytic Network process, as a model to evaluate the value of competing Electronics projects. The research paper concludes with a case study describing the implementation of this model at an engineering college, including data based on the actual use of the decision making model. The case study helps to verify that AHP is an effective and efficient decision-making tool. A major contribution of this work is to provide a methodology for assessing the best project. Despite a number of publications applying AHP in project selection, this is probably the first time that an attempt has been made to apply AHP in an electronics project selection in an engineering university environment. (author)

  3. Advanced methods for teaching electronic-nose technologies to diagnosticians and clinical laboratory technicians

    Science.gov (United States)

    Alphus D. Wilson

    2012-01-01

    Electronic-detection technologies and instruments increasingly are being utilized in the biomedical field to perform a wide variety of clinical operations and laboratory analyses to facilitate the delivery of health care to patients. The introduction of improved electronic instruments for diagnosing diseases and for administering treatments has required new training of...

  4. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose

    Directory of Open Access Journals (Sweden)

    Siavash Esfahani

    2016-01-01

    Full Text Available The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose—an instrument designed to replicate the biological olfactory system. Of the possible biological media available to “sniff”, urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at −80 °C. Here we investigated the effect of storage time (years on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at −80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry—a type of electronic nose. It was discovered that gas emissions (concentration and diversity reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life.

  5. Variation in Gas and Volatile Compound Emissions from Human Urine as It Ages, Measured by an Electronic Nose

    Science.gov (United States)

    Esfahani, Siavash; Sagar, Nidhi M.; Kyrou, Ioannis; Mozdiak, Ella; O’Connell, Nicola; Nwokolo, Chuka; Bardhan, Karna D.; Arasaradnam, Ramesh P.; Covington, James A.

    2016-01-01

    The medical profession is becoming ever more interested in the use of gas-phase biomarkers for disease identification and monitoring. This is due in part to its rapid analysis time and low test cost, which makes it attractive for many different clinical arenas. One technology that is showing promise for analyzing these gas-phase biomarkers is the electronic nose—an instrument designed to replicate the biological olfactory system. Of the possible biological media available to “sniff”, urine is becoming ever more important as it is easy to collect and to store for batch testing. However, this raises the question of sample storage shelf-life, even at −80 °C. Here we investigated the effect of storage time (years) on stability and reproducibility of total gas/vapour emissions from urine samples. Urine samples from 87 patients with Type 2 Diabetes Mellitus were collected over a four-year period and stored at −80 °C. These samples were then analyzed using FAIMS (field-asymmetric ion mobility spectrometry—a type of electronic nose). It was discovered that gas emissions (concentration and diversity) reduced over time. However, there was less variation in the initial nine months of storage with greater uniformity and stability of concentrations together with tighter clustering of the total number of chemicals released. This suggests that nine months could be considered a general guide to a sample shelf-life. PMID:26821055

  6. Discrimination and characterization of strawberry juice based on electronic nose and tongue: comparison of different juice processing approaches by LDA, PLSR, RF, and SVM.

    Science.gov (United States)

    Qiu, Shanshan; Wang, Jun; Gao, Liping

    2014-07-09

    An electronic nose (E-nose) and an electronic tongue (E-tongue) have been used to characterize five types of strawberry juices based on processing approaches (i.e., microwave pasteurization, steam blanching, high temperature short time pasteurization, frozen-thawed, and freshly squeezed). Juice quality parameters (vitamin C, pH, total soluble solid, total acid, and sugar/acid ratio) were detected by traditional measuring methods. Multivariate statistical methods (linear discriminant analysis (LDA) and partial least squares regression (PLSR)) and neural networks (Random Forest (RF) and Support Vector Machines) were employed to qualitative classification and quantitative regression. E-tongue system reached higher accuracy rates than E-nose did, and the simultaneous utilization did have an advantage in LDA classification and PLSR regression. According to cross-validation, RF has shown outstanding and indisputable performances in the qualitative and quantitative analysis. This work indicates that the simultaneous utilization of E-nose and E-tongue can discriminate processed fruit juices and predict quality parameters successfully for the beverage industry.

  7. SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

    International Nuclear Information System (INIS)

    Jin, L; Eldib, A; Li, J; Price, R; Ma, C

    2015-01-01

    Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin

  8. Theoretical and practical considerations for teaching diagnostic electronic-nose technologies to clinical laboratory technicians

    Science.gov (United States)

    Alphus D. Wilson

    2012-01-01

    The rapid development of new electronic technologies and instruments, utilized to perform many current clinical operations in the biomedical field, is changing the way medical health care is delivered to patients. The majority of test results from laboratory analyses, performed with these analytical instruments often prior to clinical examinations, are frequently used...

  9. A novel method to quantify the activity of alcohol acetyltransferase Using a SnO2-based sensor of electronic nose.

    Science.gov (United States)

    Hu, Zhongqiu; Li, Xiaojing; Wang, Huxuan; Niu, Chen; Yuan, Yahong; Yue, Tianli

    2016-07-15

    Alcohol acetyltransferase (AATFase) extensively catalyzes the reactions of alcohols to acetic esters in microorganisms and plants. In this work, a novel method has been proposed to quantify the activity of AATFase using a SnO2-based sensor of electronic nose, which was determined on the basis of its higher sensitivity to the reducing alcohol than the oxidizing ester. The maximum value of the first-derivative of the signals from the SnO2-based sensor was therein found to be an eigenvalue of isoamyl alcohol concentration. Quadratic polynomial regression perfectly fitted the correlation between the eigenvalue and the isoamyl alcohol concentration. The method was used to determine the AATFase activity in this type of reaction by calculating the conversion rate of isoamyl alcohol. The proposed method has been successfully applied to determine the AATFase activity of a cider yeast strain. Compared with GC-MS, the method shows promises with ideal recovery and low cost. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Changes in the aromatic profile of espresso coffee as a function of the grinding grade and extraction time: a study by the electronic nose system.

    Science.gov (United States)

    Severini, C; Ricci, I; Marone, M; Derossi, A; De Pilli, T

    2015-03-04

    The changes in chemical attributes and aromatic profile of espresso coffee (EC) were studied taking into account the extraction time and grinding level as independent variables. Particularly, using an electronic nose system, the changes of the global aromatic profile of EC were highlighted. The results shown as the major amounts of organic acids, solids, and caffeine were extracted in the first 8 s of percolation. The grinding grade significantly affected the quality of EC probably as an effect of the particle size distribution and the percolation pathways of water through the coffee cake. The use of an electronic nose system allowed us to discriminate the fractions of the brew as a function of the percolation time and also the regular coffee obtained from different grinding grades. Particularly, the aromatic profile of a regular coffee (25 mL) was significantly affected by the grinding level of the coffee grounds and percolation time, which are two variables under the control of the bar operator.

  11. Quasi Real Time Data Analysis for Air Quality Monitoring with an Electronic Nose

    Science.gov (United States)

    Zhou, Hanying; Shevade, Abhijit V.; Pelletier, Christine C.; Homer, Margie L.; Ryan, M. Amy

    2006-01-01

    Cabin Air Quality Monitoring: A) Functions; 1) Incident monitor for targeted contaminants exceeding targeted concentrations. Identify and quantify. 2) Monitor for presence of compounds associated with fires or overheating electronics. 3) Monitor clean-up process. B) Characteristics; 1) Low mass, low power device. 2) Requires little crew time for maintenance and calibration. 3) Detects, identifies and quantifies selected chemical species at or below 24 hour SMAC.

  12. Studies on the aroma of different species and strains of Pleurotus measured by GC/MS, sensory analysis and electronic nose

    OpenAIRE

    Renata Zawirska-Wojtasiak; Marek Siwulski; Sylwia Mildner-Szkudlarz; Erwin Wąsowicz

    2009-01-01

    The aroma of several strains of Pleurotus ostreatus, Pleurotus citrinopileatus and Pleurotus djamor was studied by GC/MS. Three main mushrooms aroma constituents: 3-octanol, 3-octanone and 1-octen-3-ol were taken into account for quantitative measurements. The highest amount of 1-octen-3-ol was recorded in P. ostreatus, while considerably lower amounts in P. citrinopileatus. Sensory profile analysis as well as the electronic nose also varied between the three species of Pleurotus. Chiral gas ...

  13. Determining degree of roasting in cocoa beans by artificial neural network (ANN)-based electronic nose system and gas chromatography/mass spectrometry (GC/MS).

    Science.gov (United States)

    Tan, Juzhong; Kerr, William L

    2018-08-01

    Roasting is a critical step in chocolate processing, where moisture content is decreased and unique flavors and texture are developed. The determination of the degree of roasting in cocoa beans is important to ensure the quality of chocolate. Determining the degree of roasting relies on human specialists or sophisticated chemical analyses that are inaccessible to small manufacturers and farmers. In this study, an electronic nose system was constructed consisting of an array of gas sensors and used to detect volatiles emanating from cocoa beans roasted for 0, 20, 30 and 40 min. The several signals were used to train a three-layer artificial neural network (ANN). Headspace samples were also analyzed by gas chromatography/mass spectrometry (GC/MS), with 23 select volatiles used to train a separate ANN. Both ANNs were used to predict the degree of roasting of cocoa beans. The electronic nose had a prediction accuracy of 94.4% using signals from sensors TGS 813, 826, 822, 830, 830, 2620, 2602 and 2610. In comparison, the GC/MS predicted the degree of roasting with an accuracy of 95.8%. The electronic nose system is able to predict the extent of roasting, as well as a more sophisticated approach using GC/MS. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  14. Biological compost stability influences odor molecules production measured by electronic nose during food-waste high-rate composting

    International Nuclear Information System (INIS)

    D'Imporzano, Giuliana; Crivelli, Fernando; Adani, Fabrizio

    2008-01-01

    Composting is a technique that is used to convert organic waste into agriculturally useful products. Composting is an aerobic, solid-state biological process, which typically can be divided into two phases, a high-rate composting phase and a curing phase. High-rate composting plays an important role during the composting process, owing to the high microbial activity occurring during this phase. It requires an accurate plant design to prevent the formation of anaerobic conditions and odors. The formation of anaerobic conditions mainly depends on the rate of O 2 consumption needed to degrade the substrate, i.e., the biological stability of the substrate. In this study, we investigated the relationship between the biological activity, measured by the dynamic respiration index (DRI) and the odor molecules production, measured by an electronic nose (EN) during two food-waste high-rate composting processes. Although the O 2 concentration in the biomass free air space (FAS) was kept optimal (O 2 > 140 ml l -1 , v/v) during composting, strong anaerobic conditions developed. This was indicated by the high levels of sulfur compounds, methane, and hydrogen in the outlet air stream. Both the high level of O 2 consumption, needed to degrade the high-degradable water-soluble organic matter and the low water O 2 solubility, caused by high temperature reached in this stage (up to 60 deg. C), led to the anaerobic conditions observed in the biofilm-particle level. The application of the partial least square (PLS) analysis demonstrated a good regression between the DRI and the odor molecules produced that was detected by the EN (R 2 = 0.991; R 2 CV = 0.990), signifying the usefulness of the DRI as a parameter to estimate the potential production of odor molecules of the biomass

  15. Nondestructive measurement of total volatile basic nitrogen (TVB-N) in pork meat by integrating near infrared spectroscopy, computer vision and electronic nose techniques.

    Science.gov (United States)

    Huang, Lin; Zhao, Jiewen; Chen, Quansheng; Zhang, Yanhua

    2014-02-15

    Total volatile basic nitrogen (TVB-N) content is an important reference index for evaluating pork freshness. This paper attempted to measure TVB-N content in pork meat using integrating near infrared spectroscopy (NIRS), computer vision (CV), and electronic nose (E-nose) techniques. In the experiment, 90 pork samples with different freshness were collected for data acquisition by three different techniques, respectively. Then, the individual characteristic variables were extracted from each sensor. Next, principal component analysis (PCA) was used to achieve data fusion based on these characteristic variables from 3 different sensors data. Back-propagation artificial neural network (BP-ANN) was used to construct the model for TVB-N content prediction, and the top principal components (PCs) were extracted as the input of model. The result of the model was achieved as follows: the root mean square error of prediction (RMSEP) = 2.73 mg/100g and the determination coefficient (R(p)(2)) = 0.9527 in the prediction set. Compared with single technique, integrating three techniques, in this paper, has its own superiority. This work demonstrates that it has the potential in nondestructive detection of TVB-N content in pork meat using integrating NIRS, CV and E-nose, and data fusion from multi-technique could significantly improve TVB-N prediction performance. Copyright © 2013. Published by Elsevier Ltd.

  16. Scanning probe methods applied to molecular electronics

    Energy Technology Data Exchange (ETDEWEB)

    Pavlicek, Niko

    2013-08-01

    Scanning probe methods on insulating films offer a rich toolbox to study electronic, structural and spin properties of individual molecules. This work discusses three issues in the field of molecular and organic electronics. An STM head to be operated in high magnetic fields has been designed and built up. The STM head is very compact and rigid relying on a robust coarse approach mechanism. This will facilitate investigations of the spin properties of individual molecules in the future. Combined STM/AFM studies revealed a reversible molecular switch based on two stable configurations of DBTH molecules on ultrathin NaCl films. AFM experiments visualize the molecular structure in both states. Our experiments allowed to unambiguously determine the pathway of the switch. Finally, tunneling into and out of the frontier molecular orbitals of pentacene molecules has been investigated on different insulating films. These experiments show that the local symmetry of initial and final electron wave function are decisive for the ratio between elastic and vibration-assisted tunneling. The results can be generalized to electron transport in organic materials.

  17. Statistics techniques applied to electron probe microanalysis

    International Nuclear Information System (INIS)

    Brizuela, H.; Del Giorgio, M.; Budde, C.; Briozzo, C.; Riveros, J.

    1987-01-01

    A description of Montroll-West's general theory for a tridimensional random walk of a particle with internal degrees of freedom is given, connecting this problem with the master equation solution. The possibility of its application to EPMA is discussed. Numerical solutions are given for thick or collimated beams at several energies interacting with samples of different shape and size. Spatial distribution of particles within the sample -for a stationary state- is analized, as well as the electron backscattering coefficient. (Author) [es

  18. Applying power electronics to residential HVAC

    International Nuclear Information System (INIS)

    Sulfstede, L.

    1991-01-01

    This paper outlines several of the market and application issues bearing on the economics residential variable speed air conditioners and heat pumps. Technical details of capacity modulized systems have been avoided, along with design issues and tradeoffs involving power semiconductors, motor torque and speed control strategies- and silicon integration for these applications. The intention is to provoke new creative technical solutions but perhaps more importantly, to involve new marketing strategies that will develop the mature potential of air conditioning products containing power electronics to enable them to generate the tough HVAC market, competing successfully against conventional systems

  19. Detection of Helicobacter pylori infection by examination of human breath odor using electronic nose Bloodhound-214ST

    Science.gov (United States)

    Shnayder, E. P.; Moshkin, M. P.; Petrovskii, D. V.; Shevela, A. I.; Babko, A. N.; Kulikov, V. G.

    2009-05-01

    Our aim was to examine the possibility of use e-nose Bloodhound-214ST to determine presence or absence of H. pylori infection using exhalation samples of patients. Breath samples were collected twice: at baseline and after oral administration of 500 mg of urea. H. pylori status of patients was confirmed by antral biopsy. Using two approaches for the data analysis we showed the possibility to distinguish H. pylori free and infected patients.

  20. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    Science.gov (United States)

    Berger, Cezar Augusto Sarraf; Freitas, Renato da Silva; Malafaia, Osvaldo; Pinto, José Simão de Paula; Macedo Filho, Evaldo Dacheux; Mocellin, Marcos; Fagundes, Marina Serrato Coelho

    2014-01-01

    Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©). The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%). The most common dorsum technique was hump removal (33.33%), and the predominance of sutures (24.76%) was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%). Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures. PMID:25992149

  1. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    Directory of Open Access Journals (Sweden)

    Berger, Cezar Augusto Sarraf

    2014-12-01

    Full Text Available Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©. The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%. The most common dorsum technique was hump removal (33.33%, and the predominance of sutures (24.76% was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%. Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures.

  2. Effect of hot air drying on volatile compounds of Flammulina velutipes detected by HS-SPME-GC-MS and electronic nose.

    Science.gov (United States)

    Yang, Wenjian; Yu, Jie; Pei, Fei; Mariga, Alfred Mugambi; Ma, Ning; Fang, Yong; Hu, Qiuhui

    2016-04-01

    Volatile compounds are important factors that affect the flavor quality of Flammulina velutipes, but the changes occurring during hot air drying is still unclear. To clarify the dynamic changes of flavor components during hot air drying, comprehensive flavor characterization and volatile compounds of F. velutipes were evaluated using electronic nose technology and headspace solid phase micro-extraction combined with gas chromatography-mass spectrometry (HS-SPME-GC-MS), respectively. Results showed that volatile components in F. velutipes significantly changed during hot air drying according to the principal component analysis and radar fingerprint chart of electronic nose. Volatile compounds of fresh F. velutipes consisted mainly of ketones, aldehydes and alcohols, and 3-octanone was the dominant compound. Drying process could significantly decrease the relative content of ketones and promoted the generation of alcohols, acids, and esters, which became the main volatile compounds of dried F. velutipes. These may provide a theoretical basis for the formation mechanism of flavor substances in dried F. velutipes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A Local Weighted Nearest Neighbor Algorithm and a Weighted and Constrained Least-Squared Method for Mixed Odor Analysis by Electronic Nose Systems

    Directory of Open Access Journals (Sweden)

    Jyuo-Min Shyu

    2010-11-01

    Full Text Available A great deal of work has been done to develop techniques for odor analysis by electronic nose systems. These analyses mostly focus on identifying a particular odor by comparing with a known odor dataset. However, in many situations, it would be more practical if each individual odorant could be determined directly. This paper proposes two methods for such odor components analysis for electronic nose systems. First, a K-nearest neighbor (KNN-based local weighted nearest neighbor (LWNN algorithm is proposed to determine the components of an odor. According to the component analysis, the odor training data is firstly categorized into several groups, each of which is represented by its centroid. The examined odor is then classified as the class of the nearest centroid. The distance between the examined odor and the centroid is calculated based on a weighting scheme, which captures the local structure of each predefined group. To further determine the concentration of each component, odor models are built by regressions. Then, a weighted and constrained least-squares (WCLS method is proposed to estimate the component concentrations. Experiments were carried out to assess the effectiveness of the proposed methods. The LWNN algorithm is able to classify mixed odors with different mixing ratios, while the WCLS method can provide good estimates on component concentrations.

  4. Discrimination Method of the Volatiles from Fresh Mushrooms by an Electronic Nose Using a Trapping System and Statistical Standardization to Reduce Sensor Value Variation

    Directory of Open Access Journals (Sweden)

    Kouki Fujioka

    2013-11-01

    Full Text Available Electronic noses have the benefit of obtaining smell information in a simple and objective manner, therefore, many applications have been developed for broad analysis areas such as food, drinks, cosmetics, medicine, and agriculture. However, measurement values from electronic noses have a tendency to vary under humidity or alcohol exposure conditions, since several types of sensors in the devices are affected by such variables. Consequently, we show three techniques for reducing the variation of sensor values: (1 using a trapping system to reduce the infering components; (2 performing statistical standardization (calculation of z-score; and (3 selecting suitable sensors. With these techniques, we discriminated the volatiles of four types of fresh mushrooms: golden needle (Flammulina velutipes, white mushroom (Agaricus bisporus, shiitake (Lentinus edodes, and eryngii (Pleurotus eryngii among six fresh mushrooms (hen of the woods (Grifola frondosa, shimeji (Hypsizygus marmoreus plus the above mushrooms. Additionally, we succeeded in discrimination of white mushroom, only comparing with artificial mushroom flavors, such as champignon flavor and truffle flavor. In conclusion, our techniques will expand the options to reduce variations in sensor values.

  5. Comparison of an Electronic Nose Based on Ultrafast Gas Chromatography, Comprehensive Two-Dimensional Gas Chromatography, and Sensory Evaluation for an Analysis of Type of Whisky

    Directory of Open Access Journals (Sweden)

    Paulina Wiśniewska

    2017-01-01

    Full Text Available Whisky is one of the most popular alcoholic beverages. There are many types of whisky, for example, Scotch, Irish, and American whisky (called bourbon. The whisky market is highly diversified, and, because of this, it is important to have a method which would enable rapid quality evaluation and authentication of the type of whisky. The aim of this work was to compare 3 methods: an electronic nose based on the technology of ultrafast gas chromatography (Fast-GC, comprehensive two-dimensional gas chromatography (GC × GC, and sensory evaluation. The selected whisky brands included 6 blended whiskies from Scotland, 4 blended whiskies from Ireland, and 4 bourbons produced in the USA. For data analysis, peak heights of chromatograms were used. The panelists who took part in sensory evaluations included 4 women and 4 men. The obtained data were analyzed by 2 chemometric methods: partial least squares discriminant analysis (PLS-DA and discrimination function analysis (DFA. E-nose and GC × GC allowed for differentiation between whiskies by type. Sensory analysis did not allow for differentiation between whiskies by type, but it allowed giving consumer preferences.

  6. Memory function formalism applied to electronic transport in disordered systems

    International Nuclear Information System (INIS)

    Cunha Lima, I.C. da

    1984-01-01

    Memory function formalism is briefly reviewed and applied to electronic transport using the projection operator technique. The resistivity of a disordered 2-D electron gas under strong magnetic field is obtained in terms of force-force correlation function. (Author) [pt

  7. Color, flavor, and sensory characteristics of gamma-irradiated salted and fermented anchovy sauce[Gamma irradiation; Fermented anchovy; Color; Flavor compounds; Electronic nose; Sensory evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J.H.; Ahn, Hyun Joo; Yook, Hong Sun; Kim, Kyong Soo; Rhee, Moon Soo; Ryu, Gi Hyung; Byun, Myung Woo E-mail: mwbyun@kaeri.re.kr

    2004-02-01

    Color, flavor, and sensory characteristics of irradiated salted and fermented anchovy sauce were investigated. The filtrate of salted and fermented anchovy was irradiated at 0, 2.5, 5, 7.5, and 10 kGy. After irradiation, Hunter's color values were increased, however, the color values were gradually decreased in all samples during storage. Amount of the aldehydes, esters, ketones, S-containing compounds, and the other groups were increased up to 7.5 kGy irradiation, then decreased at 10 kGy (P<0.05), while the alcohols and furan groups were increased by irradiation. Different odor patterns were observed among samples using electronic nose system analysis. Gamma-irradiated samples showed better sensory score and the quality was sustained during storage. In conclusion, gamma irradiation of salted and fermented anchovy sauce could improve its sensory quality by reducing typical fishy smell.

  8. An electronic-nose sensor node based on a polymer-coated surface acoustic wave array for wireless sensor network applications.

    Science.gov (United States)

    Tang, Kea-Tiong; Li, Cheng-Han; Chiu, Shih-Wen

    2011-01-01

    This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW) sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K(2) 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT) was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC) was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN) applications.

  9. An Electronic-Nose Sensor Node Based on a Polymer-Coated Surface Acoustic Wave Array for Wireless Sensor Network Applications

    Science.gov (United States)

    Tang, Kea-Tiong; Li, Cheng-Han; Chiu, Shih-Wen

    2011-01-01

    This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW) sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K2 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT) was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC) was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN) applications. PMID:22163865

  10. An Electronic-Nose Sensor Node Based on a Polymer-Coated Surface Acoustic Wave Array for Wireless Sensor Network Applications

    Directory of Open Access Journals (Sweden)

    Kea-Tiong Tang

    2011-04-01

    Full Text Available This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K2 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN applications.

  11. Electronic-projecting Moire method applying CBR-technology

    Science.gov (United States)

    Kuzyakov, O. N.; Lapteva, U. V.; Andreeva, M. A.

    2018-01-01

    Electronic-projecting method based on Moire effect for examining surface topology is suggested. Conditions of forming Moire fringes and their parameters’ dependence on reference parameters of object and virtual grids are analyzed. Control system structure and decision-making subsystem are elaborated. Subsystem execution includes CBR-technology, based on applying case base. The approach related to analysing and forming decision for each separate local area with consequent formation of common topology map is applied.

  12. Electron sheath collapse in an applied-B ion diode

    International Nuclear Information System (INIS)

    Grechikha, A.V.

    1996-01-01

    The effect of the electron sheath collapse in an applied-B ion diode due to the presence of the resistive anode plasma layer was found. This effect is more damaging at higher diode voltages and may be responsible for the parasitic load effect observed in the experiments. (author). 4 figs., 2 refs

  13. Electron sheath collapse in an applied-B ion diode

    Energy Technology Data Exchange (ETDEWEB)

    Grechikha, A V [Forschungszentrum Karlsruhe (Germany). Institut fuer Neutronenphysik und Reaktortechnik

    1997-12-31

    The effect of the electron sheath collapse in an applied-B ion diode due to the presence of the resistive anode plasma layer was found. This effect is more damaging at higher diode voltages and may be responsible for the parasitic load effect observed in the experiments. (author). 4 figs., 2 refs.

  14. Love Acoustic Wave-Based Devices and Molecularly-Imprinted Polymers as Versatile Sensors for Electronic Nose or Tongue for Cancer Monitoring

    Directory of Open Access Journals (Sweden)

    Corinne Dejous

    2016-06-01

    Full Text Available Cancer is a leading cause of death worldwide and actual analytical techniques are restrictive in detecting it. Thus, there is still a challenge, as well as a need, for the development of quantitative non-invasive tools for the diagnosis of cancers and the follow-up care of patients. We introduce first the overall interest of electronic nose or tongue for such application of microsensors arrays with data processing in complex media, either gas (e.g., Volatile Organic Compounds or VOCs as biomarkers in breath or liquid (e.g., modified nucleosides as urinary biomarkers. Then this is illustrated with a versatile acoustic wave transducer, functionalized with molecularly-imprinted polymers (MIP synthesized for adenosine-5′-monophosphate (AMP as a model for nucleosides. The device including the thin film coating is described, then static measurements with scanning electron microscopy (SEM and electrical characterization after each step of the sensitive MIP process (deposit, removal of AMP template, capture of AMP target demonstrate the thin film functionality. Dynamic measurements with a microfluidic setup and four targets are presented afterwards. They show a sensitivity of 5 Hz·ppm−1 of the non-optimized microsensor for AMP detection, with a specificity of three times compared to PMPA, and almost nil sensitivity to 3′AMP and CMP, in accordance with previously published results on bulk MIP.

  15. Power electronics applied to industrial systems and transports

    CERN Document Server

    Patin, Nicolas

    2015-01-01

    Power electronics is based on the switching operating mode of semiconductor components. On this basis, the concepts of type (voltage or current) and reversibility of interconnected sources make it possible to apply a methodology for the synthesis of various types of converters. This book also focuses on the importance of packaging by reviewing the electrical representation of components’ thermal models and the currently available electronics’ cooling technologies. Modeling is discussed, as well as different technological aspects used in the engineering design of an electronic power converter, useful for obtaining satisfactory performance and reliability.

  16. The Apply of Frequency Divider Circuit in Nuclear Electronics

    International Nuclear Information System (INIS)

    LIU Hefan; Zeng Bing; Zhang Ziliang; Ge Liangquan

    2009-01-01

    Different components in a digital system often need different working frequencies, the way we often used is clock division from the system clock. Through the analysis of frequency divider principle, a applied integer frequency dividing circuit with SE120A is proposed. It can divide the frequency multiple from 2 to 64. It's usually used in nuclear electronics. It's testing and analysis is displayed that it has no noise, good frequency division effect and stability. (authors)

  17. Managing of gas sensing characteristic of a reduced graphene oxide based gas sensor by the change in synthesis condition: A new approach for electronic nose design

    Energy Technology Data Exchange (ETDEWEB)

    Alizadeh, Taher, E-mail: talizadeh@ut.ac.ir [Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-6455, Tehran (Iran, Islamic Republic of); Hamedsoltani, Leyla [Department of Applied Chemistry, Faculty of Science, University of Mohaghegh Ardabili, Ardabil (Iran, Islamic Republic of)

    2016-11-01

    Natural graphite was oxidized and exfoliated via two different methods, leading to two types of graphene oxide (GO) materials. The obtained materials were reduced by three different reducing agents including: hydrazine hydrate, ascorbic acid and sodium borohydride, giving thus six kinds of reduced graphene oxide (RGO) materials. The obtained materials were characterized using Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. The RGOs were then used to fabricate different gas sensors and their electrical resistances were recorded upon exposing to various volatile organic compounds vapors (VOCs). Gas sensing selectivity of each RGO was significantly affected by the synthesis condition. The RGO-based sensor array was fabricated and its capability for discrimination of seven kinds of VOCs was evaluated, utilizing principal component analysis and cluster analysis methods. Loading plot indicated that the presence of five RGO-based sensors could effectively discriminate the aimed vapors. The electronic nose, containing five kinds of RGOs, was used for the classification of seven kinds of VOCs at their different concentrations. - Highlights: • Two oxidation procedures and three reducing agents were utilized to produce six kinds of RGOs. • The synthesized different RGOs exhibited significantly different sensing behaviors. • Seven kinds of organic vapors were chosen for the evaluation of discrimination power of EN. • Using PCA, it was found that seven of six RFGOs were appropriate number to use in final EN. • The developed EN was capable of properly discrimination of tested vapors.

  18. Qualitative characteristics and comparison of volatile fraction of vodkas made from different botanical materials by comprehensive two-dimensional gas chromatography and the electronic nose based on the technology of ultra-fast gas chromatography.

    Science.gov (United States)

    Wiśniewska, Paulina; Śliwińska, Magdalena; Dymerski, Tomasz; Wardencki, Waldemar; Namieśnik, Jacek

    2017-03-01

    Vodka is a spirit-based beverage made from ethyl alcohol of agricultural origin. At present, increasingly more vodka brands have labels that specify the botanical origin of the product. Until now, the techniques for distinguishing between vodkas of different botanical origin have been costly, time-consuming and insufficient for making a distinction between vodka produced from similar raw materials. Therefore, it is of utmost importance to find a fast and relatively inexpensive technique for conducting such tests. In the present study, we employed comprehensive two-dimensional gas chromatography (GC×GC) and an electronic nose based on the technology of ultra-fast GC with chemometric methods such as partial least square discriminant analysis, discriminant function analysis and soft independent modeling of class analogy. Both techniques allow a distinction between the vodkas produced from different raw materials. In the case of GC×GC, the differences between vodkas were more noticeable than in the analysis by electronic nose; however, the electronic nose allowed the significantly faster analysis of vodkas. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  19. Scanning electron microscopic study of the otolithic organs in the bichir (Polypterus bichir) and shovel-nose sturgeon (Scaphirhynchus platorynchus).

    Science.gov (United States)

    Popper, A N

    1978-09-01

    The anatomy and ultrastructure of the sacculus, lagena, and utriculus of the ear of Polypterus bichir and Scaphirhynchus platorynchus were studied using the scanning electron microscope. The otolithic organs each contain a single dense calcareous otolith in close contact with a sensory epithelium (macula). The maculae have sensory hair cells typical of those found in other vertebrates, surrounded by microvilli-covered supporting cells. The hair cells on each macula are divided into several groups, with all of the cells in each group morphologically polarized in the same direction. The cells of the utricular macula in both species are divided into opposing groups in a pattern similar to that found in other vertebrates. The saccular and lagenar maculae are located in a single large chamber in both species. In Scaphirhychus the two maculae are on the same plane, while in Polypterus they are at right angles to one another. The hair cells on the saccular maculae of both species are divided into two oppositely oriented groups. In Scaphirhynchus the cells on the posterior half of the macula are oriented dorsally on the dorsal half of the macula and ventrally on the ventral half. The anterior region of the macula is rotated and the cells of the dorsal and ventral groups are shifted so that they are oriented on the animal's horizon plane. A similar pattern is found in Polypterus, except that this macula is shaped like a "J" with the vertical portion of the J having horizontal cells and the bottom portion vertical cells. The lagenar maculae in both species have dorsally oriented cells on the anterior side of the macula and ventrally oriented cells on the posterior half of the macula. While these data are not sufficient for clarifying the taxonomic relationship between the two species studied, it is clear that the ears in these species have a number of significant differences from the teleost ear that could have functional and/or taxonomic significance.

  20. Comparison of SVM, RF and ELM on an Electronic Nose for the Intelligent Evaluation of Paraffin Samples

    Directory of Open Access Journals (Sweden)

    Hong Men

    2018-01-01

    Full Text Available Paraffin odor intensity is an important quality indicator when a paraffin inspection is performed. Currently, paraffin odor level assessment is mainly dependent on an artificial sensory evaluation. In this paper, we developed a paraffin odor analysis system to classify and grade four kinds of paraffin samples. The original feature set was optimized using Principal Component Analysis (PCA and Partial Least Squares (PLS. Support Vector Machine (SVM, Random Forest (RF, and Extreme Learning Machine (ELM were applied to three different feature data sets for classification and level assessment of paraffin. For classification, the model based on SVM, with an accuracy rate of 100%, was superior to that based on RF, with an accuracy rate of 98.33–100%, and ELM, with an accuracy rate of 98.01–100%. For level assessment, the R2 related to the training set was above 0.97 and the R2 related to the test set was above 0.87. Through comprehensive comparison, the generalization of the model based on ELM was superior to those based on SVM and RF. The scoring errors for the three models were 0.0016–0.3494, lower than the error of 0.5–1.0 measured by industry standard experts, meaning these methods have a higher prediction accuracy for scoring paraffin level.

  1. Plant Pest Detection Using an Artificial Nose System: A Review

    Directory of Open Access Journals (Sweden)

    Shaoqing Cui

    2018-01-01

    Full Text Available This paper reviews artificial intelligent noses (or electronic noses as a fast and noninvasive approach for the diagnosis of insects and diseases that attack vegetables and fruit trees. The particular focus is on bacterial, fungal, and viral infections, and insect damage. Volatile organic compounds (VOCs emitted from plants, which provide functional information about the plant’s growth, defense, and health status, allow for the possibility of using noninvasive detection to monitor plants status. Electronic noses are comprised of a sensor array, signal conditioning circuit, and pattern recognition algorithms. Compared with traditional gas chromatography–mass spectrometry (GC-MS techniques, electronic noses are noninvasive and can be a rapid, cost-effective option for several applications. However, using electronic noses for plant pest diagnosis is still in its early stages, and there are challenges regarding sensor performance, sampling and detection in open areas, and scaling up measurements. This review paper introduces each element of electronic nose systems, especially commonly used sensors and pattern recognition methods, along with their advantages and limitations. It includes a comprehensive comparison and summary of applications, possible challenges, and potential improvements of electronic nose systems for different plant pest diagnoses.

  2. Plant Pest Detection Using an Artificial Nose System: A Review.

    Science.gov (United States)

    Cui, Shaoqing; Ling, Peter; Zhu, Heping; Keener, Harold M

    2018-01-28

    This paper reviews artificial intelligent noses (or electronic noses) as a fast and noninvasive approach for the diagnosis of insects and diseases that attack vegetables and fruit trees. The particular focus is on bacterial, fungal, and viral infections, and insect damage. Volatile organic compounds (VOCs) emitted from plants, which provide functional information about the plant's growth, defense, and health status, allow for the possibility of using noninvasive detection to monitor plants status. Electronic noses are comprised of a sensor array, signal conditioning circuit, and pattern recognition algorithms. Compared with traditional gas chromatography-mass spectrometry (GC-MS) techniques, electronic noses are noninvasive and can be a rapid, cost-effective option for several applications. However, using electronic noses for plant pest diagnosis is still in its early stages, and there are challenges regarding sensor performance, sampling and detection in open areas, and scaling up measurements. This review paper introduces each element of electronic nose systems, especially commonly used sensors and pattern recognition methods, along with their advantages and limitations. It includes a comprehensive comparison and summary of applications, possible challenges, and potential improvements of electronic nose systems for different plant pest diagnoses.

  3. Electron inertia effects for an electron fluid model by the applied-B ion diode

    Energy Technology Data Exchange (ETDEWEB)

    Gordeev, A V; Levchenko, S V [Kurchatov Institute, Moscow (Russian Federation). Nuclear Fusion Institute

    1997-12-31

    Numerical calculations within the framework of the one-dimensional vortex-like electron fluid model in applied-B ion diodes, taking account the electron inertia effects, are presented. The existence of the additional relation between the magnetic field and the electric potential offers an opportunity to reduce the ion diode problem to the system of the algebraic equations for the constants introduced. The ion current density in an ion diode is determined only by the magnetic flux cut out by the virtual cathode. As an illustration, the ion diode impedance for the KALIF device was calculated. (author). 2 figs., 6 refs.

  4. Electron beam irradiation and zeolites adsorption applied to dyeing effluents

    International Nuclear Information System (INIS)

    Higa, Marcela C.; Fungaro, Denise A.; Somessari, Elizabeth S.R.; Magdalena, Carina P.; Grosche, Lucas C.; NNeto, Antonio C.; Borrely, Sueli I.

    2007-01-01

    Wastewater generated from the textile industries contain large amount of azo dyes and many of them present low biodegradability capability. Today several countries are facing with evidences that water pollution is related to toxicity, mutagenicity and carcinogenic nature. Once reactive dyes are commercial products they will be discharged to the waterways and rivers causing ecological damages and health problems. The aim of this paper was to consider the potential of two techniques for colour and toxicity removal: ionizing radiation and adsorption by zeolites synthesized from fly ash. Real effluents from chemical and textile industries (hardly coloured) were submitted to radiation and adsorption using zeolites. It was necessary to dilute some effluents prior the treatments in order to get any success. When electrons irradiation was performed radiation doses applied were from 0.5 kGy up to 20 kGy. This radiation process accounted for a partial decolouring as higher doses were implemented. Coal fly ashes were used as starting material for zeolite synthesis by means of hydrothermal treatment with alkaline medium. The adsorption was performed by batch experiments. It was obtained about 77% - 90% color removal from dye wastewater after 24h of contact time with two types of zeolite. The irradiation accounted for 72% of the initial toxicity. The ionizing radiation and adsorption by zeolites synthesized from fly ash can be used as an alternative for the treatment of aqueous waste containing dyes. (author)

  5. Applied economic model development algorithm for electronics company

    Directory of Open Access Journals (Sweden)

    Mikhailov I.

    2017-01-01

    Full Text Available The purpose of this paper is to report about received experience in the field of creating the actual methods and algorithms that help to simplify development of applied decision support systems. It reports about an algorithm, which is a result of two years research and have more than one-year practical verification. In a case of testing electronic components, the time of the contract conclusion is crucial point to make the greatest managerial mistake. At this stage, it is difficult to achieve a realistic assessment of time-limit and of wage-fund for future work. The creation of estimating model is possible way to solve this problem. In the article is represented an algorithm for creation of those models. The algorithm is based on example of the analytical model development that serves for amount of work estimation. The paper lists the algorithm’s stages and explains their meanings with participants’ goals. The implementation of the algorithm have made possible twofold acceleration of these models development and fulfilment of management’s requirements. The resulting models have made a significant economic effect. A new set of tasks was identified to be further theoretical study.

  6. Modified electron acoustic field and energy applied to observation data

    Energy Technology Data Exchange (ETDEWEB)

    Abdelwahed, H. G., E-mail: hgomaa-eg@yahoo.com, E-mail: hgomaa-eg@mans.edu.eg [College of Science and Humanitarian Studies, Physics Department, Prince Sattam Bin Abdul Aziz University, Alkharj 11942 (Saudi Arabia); Theoretical Physics Research Group, Physics Department, Faculty of Science, Mansoura University, Mansoura 35516 (Egypt); El-Shewy, E. K. [Theoretical Physics Research Group, Physics Department, Faculty of Science, Mansoura University, Mansoura 35516 (Egypt)

    2016-08-15

    Improved electrostatic acoustic field and energy have been debated in vortex trapped hot electrons and fluid of cold electrons with pressure term plasmas. The perturbed higher-order modified-Korteweg-de Vries equation (PhomKdV) has been worked out. The effect of trapping and electron temperatures on the electro-field and energy properties in auroral plasmas has been inspected.

  7. Foreign body in the nose

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/000037.htm Foreign body in the nose To use the sharing features ... in a normal attempt to explore their own bodies. Objects placed in the nose may include food, ...

  8. Applied dosimetry to ionization techniques by electron beams

    International Nuclear Information System (INIS)

    Kuntz, F.

    1991-12-01

    After a general introduction about electron beam dosimetry, the second part is about the determination of treatment parameter for an electron ionization: are treated the problems of electron path determination, treatment depth of a product and finally, the radiation dose heterogeneities in all the volume of a treated product. The third part describes a process that greatly reduces radiation dose heterogeneity and then industrial interest is analyzed. The fourth part describes 2 applications of diffusion screen utilization. 66 figs

  9. Efficient electronic structure methods applied to metal nanoparticles

    DEFF Research Database (Denmark)

    Larsen, Ask Hjorth

    of efficient approaches to density functional theory and the application of these methods to metal nanoparticles. We describe the formalism and implementation of localized atom-centered basis sets within the projector augmented wave method. Basis sets allow for a dramatic increase in performance compared....... The basis set method is used to study the electronic effects for the contiguous range of clusters up to several hundred atoms. The s-electrons hybridize to form electronic shells consistent with the jellium model, leading to electronic magic numbers for clusters with full shells. Large electronic gaps...... and jumps in Fermi level near magic numbers can lead to alkali-like or halogen-like behaviour when main-group atoms adsorb onto gold clusters. A non-self-consistent NewnsAnderson model is used to more closely study the chemisorption of main-group atoms on magic-number Au clusters. The behaviour at magic...

  10. Power electronics applied to industrial systems and transports

    CERN Document Server

    Patin, Nicolas

    2015-01-01

    If the operation of electronic components switching scheme to reduce congestion and losses (in power converters in general and switching power supplies in particular), it also generates electromagnetic type of pollution in its immediate environment. Power Electronics for Industry and Transport, Volume 4 is devoted to electromagnetic compatibility. It presents the sources of disturbance and the square wave signal, spectral modeling generic perturbation. Disturbances propagation mechanisms called ""lumped"" by couplings such as a common impedance, a parasitic capacitance or a mutual and ""dis

  11. Dosimetric intercomparison between protons and electrons therapies applied to retinoblastoma

    International Nuclear Information System (INIS)

    Braga, Flavia Vieira

    2008-01-01

    In this work we propose a construction of a simple human eye model in order to simulate the dosimetric response for a treatment with protons and electrons in a retinoblastoma cancer. The computational tool used in this simulation was the Geant4 code, in the version 4.9.1, all these package are free and permit simulate the interaction of radiation with matter. In our simulation we use a box with 4 cm side, with water, for represent the human eye. The simulation was performed considering mono energetics beams of protons and electrons with energy range between 50 and 70 MeV for protons and 2 and 10 MeV for electrons. The simulation was based on the advanced hadron therapy example of the Geant 4 code. In these example the phantom is divided in voxels with 0.2 mm side and it is generated the energy deposited in each voxel. The simulation results show the energy deliver in each voxel, with these energie we can calculate the dose deposited in that region. We can see the dose profile of, proton and electron, and we can see in both cases that for protons the position of delivered dose is well know, that happen in the position where the proton stop, for electrons the energies is delivered along the way and pass the desired position for high dose deposition. (author)

  12. Medipix 2 detector applied to low energy electron microscopy

    International Nuclear Information System (INIS)

    Gastel, R. van; Sikharulidze, I.; Schramm, S.; Abrahams, J.P.; Poelsema, B.; Tromp, R.M.; Molen, S.J. van der

    2009-01-01

    Low energy electron microscopy (LEEM) and photo-emission electron microscopy (PEEM) traditionally use microchannel plates (MCPs), a phosphor screen and a CCD-camera to record images and diffraction patterns. In recent years, however, MCPs have become a limiting factor for these types of microscopy. Here, we report on a successful test series using a solid state hybrid pixel detector, Medipix 2, in LEEM and PEEM. Medipix 2 is a background-free detector with an infinite dynamic range, making it very promising for both real-space imaging and spectroscopy. We demonstrate a significant enhancement of both image contrast and resolution, as compared to MCPs. Since aging of the Medipix 2 detector is negligible for the electron energies used in LEEM/PEEM, we expect Medipix to become the detector of choice for a new generation of systems.

  13. Medipix 2 detector applied to low energy electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gastel, R. van, E-mail: R.vanGastel@utwente.nl [University of Twente, MESA Institute for Nanotechnology, P.O. Box 217, NL-7500 AE Enschede (Netherlands); Sikharulidze, I. [Leiden University, Leiden Institute of Chemistry, P.O. Box 9502, NL-2300 RA Leiden (Netherlands); Schramm, S. [Leiden University, Kamerlingh Onnes Laboratorium, P.O. Box 9504, NL-2300 RA Leiden (Netherlands); Abrahams, J.P. [Leiden University, Leiden Institute of Chemistry, P.O. Box 9502, NL-2300 RA Leiden (Netherlands); Poelsema, B. [University of Twente, MESA Institute for Nanotechnology, P.O. Box 217, NL-7500 AE Enschede (Netherlands); Tromp, R.M. [Leiden University, Kamerlingh Onnes Laboratorium, P.O. Box 9504, NL-2300 RA Leiden (Netherlands); IBM Research Division, T. J. Watson Research Center, P.O. Box 218, Yorktown Heights, NY 10598 (United States); Molen, S.J. van der [Leiden University, Kamerlingh Onnes Laboratorium, P.O. Box 9504, NL-2300 RA Leiden (Netherlands)

    2009-12-15

    Low energy electron microscopy (LEEM) and photo-emission electron microscopy (PEEM) traditionally use microchannel plates (MCPs), a phosphor screen and a CCD-camera to record images and diffraction patterns. In recent years, however, MCPs have become a limiting factor for these types of microscopy. Here, we report on a successful test series using a solid state hybrid pixel detector, Medipix 2, in LEEM and PEEM. Medipix 2 is a background-free detector with an infinite dynamic range, making it very promising for both real-space imaging and spectroscopy. We demonstrate a significant enhancement of both image contrast and resolution, as compared to MCPs. Since aging of the Medipix 2 detector is negligible for the electron energies used in LEEM/PEEM, we expect Medipix to become the detector of choice for a new generation of systems.

  14. Power electronics applied to industrial systems and transports

    CERN Document Server

    Patin, Nicolas

    2015-01-01

    This book provides a comprehensive overview of power electronic converters (DC / DC, DC / AC, AC / DC and AC / AC) conventionally used in industrial and transportation applications, specifically for the supply of electric machines with variable speed drop off window. From the perspective of design and sizing, this book presents the different functions encountered in a modular way for power electronics.Power Converters and Their Control details less traditional topics such as matrix converters and multilevel converters. This book also features a case study design of an industrial controller, wh

  15. Power electronics applied to industrial systems and transports

    CERN Document Server

    Patin, Nicolas

    2015-01-01

    Some power electronic converters are specifically designed to power equipment under a smoothed DC voltage. Therefore, the filtering part necessarily involves the use of auxiliary passive components (inductors and capacitors). This book deals with technical aspects such as classical separation between isolated and non-isolated power supplies, and soft switching through a special converter. It addresses the problem of regulating the output voltage of the switching power supplies in terms of modeling and obtaining transfer of SMPS functions.Power Electronics for Industry and Transport, Volume 3,

  16. Applied nonlinear optics in the journal 'Quantum Electronics'

    International Nuclear Information System (INIS)

    Grechin, Sergei G; Dmitriev, Valentin G; Chirkin, Anatolii S

    2011-01-01

    A brief historical review of the experimental and theoretical works on nonlinear optical frequency conversion (generation of harmonics, up- and down-conversion, parametric oscillation), which have been published in the journal 'Quantum Electronics' for the last 40 years, is presented.

  17. The average Indian female nose.

    Science.gov (United States)

    Patil, Surendra B; Kale, Satish M; Jaiswal, Sumeet; Khare, Nishant; Math, Mahantesh

    2011-12-01

    This study aimed to delineate the anthropometric measurements of the noses of young women of an Indian population and to compare them with the published ideals and average measurements for white women. This anthropometric survey included a volunteer sample of 100 young Indian women ages 18 to 35 years with Indian parents and no history of previous surgery or trauma to the nose. Standardized frontal, lateral, oblique, and basal photographs of the subjects' noses were taken, and 12 standard anthropometric measurements of the nose were determined. The results were compared with published standards for North American white women. In addition, nine nasal indices were calculated and compared with the standards for North American white women. The nose of Indian women differs significantly from the white nose. All the nasal measurements for the Indian women were found to be significantly different from those for North American white women. Seven of the nine nasal indices also differed significantly. Anthropometric analysis suggests differences between the Indian female nose and the North American white nose. Thus, a single aesthetic ideal is inadequate. Noses of Indian women are smaller and wider, with a less projected and rounded tip than the noses of white women. This study established the nasal anthropometric norms for nasal parameters, which will serve as a guide for cosmetic and reconstructive surgery in Indian women.

  18. 75 FR 69471 - Sony Electronics, Inc.; Amended Certification Regarding Eligibility To Apply for Worker...

    Science.gov (United States)

    2010-11-12

    ....] Sony Electronics, Inc.; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance TA-W-71,501, Sony Electronics, Inc., SEL Headquarters, Including On- Site Leased Workers of Selectremedy, Staffmark, and Payrolling.com , San Diego, California; TA-W-71,501A, Sony Electronics, Inc...

  19. New Electronic Technology Applied in Flexible Organic Optical System

    Directory of Open Access Journals (Sweden)

    Andre F. S. Guedes

    2014-02-01

    Full Text Available The synthesis and application of new organic materials, nanostructured, for developing technology based on organic devices, have been the main focus of the scientific community. In recent years, the first polymeric electronics products have entered the market (organic semiconductor materials and there are some electrochromic devices among them that have been called smart windows, once they control the passage of light or heat through a closed environment as an ordinary window. The main functional aspect of electrochromic devices, when being used in architectural and automotive industry, is to control the passage of light and temperature with thermal and visual comfort. These devices can be flexible and very thin, not containing heavy metals, and formed by layers of organic material deposited in several architectures. In this study, the electro-deposition of organic materials in the Polyaniline, PANI case, which provide stability in optical and electrical parameters, was utilized with the means of developing prototypes of organic electrochromic devices. These materials were characterized by: ultraviolet-visible spectroscopy absorption (UV-Vis, measurement of thickness (MT and electrical measurements (EM. This study aims to establish the relationship between the thickness of the active layer and the value of the electrical resistivity of the layer deposited through an electro-deposition technique. The experimental results enabled the equating of the electrical resistivity related to the thickness of the deposited layer. The linear fit of these results has expressed the thickness of the conducting layer, α, and the lowest value of the electrical resistivity, β, associated with the gap between the valence band and the conduction band. Thus, the results have demonstrated that, when the layer of organic material is completely conductive, we may obtain the thickness of the organic material deposited on the substrate.

  20. Correlation between electron-irradiation defects and applied stress in graphene: A molecular dynamics study

    Energy Technology Data Exchange (ETDEWEB)

    Kida, Shogo; Yamamoto, Masaya; Kawata, Hiroaki; Hirai, Yoshihiko; Yasuda, Masaaki, E-mail: yasuda@pe.osakafu-u.ac.jp [Department of Physics and Electronics, Osaka Prefecture University, Sakai, Osaka 599-8531 (Japan); Tada, Kazuhiro [Department of Electrical and Control Systems Engineering, National Institute of Technology, Toyama College, Toyama 939-8630 (Japan)

    2015-09-15

    Molecular dynamics (MD) simulations are performed to study the correlation between electron irradiation defects and applied stress in graphene. The electron irradiation effect is introduced by the binary collision model in the MD simulation. By applying a tensile stress to graphene, the number of adatom-vacancy (AV) and Stone–Wales (SW) defects increase under electron irradiation, while the number of single-vacancy defects is not noticeably affected by the applied stress. Both the activation and formation energies of an AV defect and the activation energy of an SW defect decrease when a tensile stress is applied to graphene. Applying tensile stress also relaxes the compression stress associated with SW defect formation. These effects induced by the applied stress cause the increase in AV and SW defect formation under electron irradiation.

  1. Seeing smells: development of an optoelectronic nose

    Directory of Open Access Journals (Sweden)

    Kenneth S. Suslick

    2007-06-01

    Full Text Available The development of an array of chemically-responsive dyes on a porous membrane and in its use as a general sensor for odors and volatile organic compounds (VOCs is reviewed. These colorimetric sensor arrays (CSA act as an "optoelectronic nose" by using an array of multiple dyes whose color changes are based on the full range of intermolecular interactions. The CSA is digitally imaged before and after exposure and the resulting difference map provides a digital fingerprint for any VOC or mixture of odorants. The result is an enormous increase in discriminatory power among odorants compared to prior electronic nose technologies. For the detection of biologically important analytes, including amines, carboxylic acids, and thiols, high sensitivities (ppbv have been demonstrated. The array is essentially non-responsive to changes in humidity due to the hydrophobicity of the dyes and membrane.

  2. A new therapeutic strategy for lengthening severe short nose.

    Science.gov (United States)

    Rikimaru, Hideaki; Kiyokawa, Kensuke; Watanabe, Koichi; Koga, Noriyuki; Nishi, Yukiko

    2010-03-01

    Correction of severe short nose is a distressing problem for plastic surgeons. It is difficult to simultaneously lengthen the 3 components of the nose, which are the outer skin envelope, the framework, and the mucosal lining. We developed a new method to lengthen the nose more than 10 mm definitively and safely, which was performed using the technique of distraction osteogenesis. The procedure involves a 2-stage operation. At the first stage, boat-shaped iliac bone is grafted on the dorsum. More than 6 months later, the second-stage operation is performed. The grafted bone is cut horizontally in the center, and the distraction device is applied to it. Distraction osteogenesis is started after a latency period of 14 days and performed at a rate of 0.6 mm once daily. The distraction device is replaced by a special attachment (Ribbond; Ribbond Inc) during the 3-month consolidation period. Our method was applied for 2 patients with congenitally and posttraumatic severe short nose, respectively. The total amount of distraction osteogenesis was 12.6 and 13.8 mm, respectively. The profiles of both of the patients improved, and they were satisfied with the results. The method we developed is an entirely new approach to the correction of severe short nose. Furthermore, it was determined that nonvascularized grafted iliac bone could be lengthened by distraction osteogenesis. Our new method was a very effective and definitive technique and could become a mainstream procedure for the correction of severe short nose.

  3. Designing the Electronic Classroom: Applying Learning Theory and Ergonomic Design Principles.

    Science.gov (United States)

    Emmons, Mark; Wilkinson, Frances C.

    2001-01-01

    Applies learning theory and ergonomic principles to the design of effective learning environments for library instruction. Discusses features of electronic classroom ergonomics, including the ergonomics of physical space, environmental factors, and workstations; and includes classroom layouts. (Author/LRW)

  4. Telesne spremembe med nosečnostjo

    OpenAIRE

    Predikaka, Sandra

    2014-01-01

    POVZETEK Nosečnost spremljajo obsežne fiziološke spremembe, ki se pojavijo že zgodaj po zanositvi. Pogosto se to zgodi, še preden se ženska zave, da je noseča. Nosečnost ni bolezen, ampak je »drugo stanje«, na to stanje se je potrebno pripraviti, saj le zdrava nosečnost prinese zdravega in primerno razvitega otroka. Namen raziskave je bil ugotoviti, kako nosečnice gledajo na telesne spremembe v nosečnosti in kako to vpliva na njihovo zadovoljstvo. Anketirali smo 100 nosečnic, ki so obi...

  5. Stuffy or runny nose - children

    Science.gov (United States)

    ... than 10 days, or produces yellow-green or gray mucus Symptoms that last more than 3 weeks ... baby or infant has a fever Images Throat anatomy Runny and stuffy nose References McGann KA, Long SS. ...

  6. Stuffy or runny nose - adult

    Science.gov (United States)

    ... than 10 days, or produces yellow-green or gray mucus Nasal discharge following a head injury Symptoms ... nose; Postnasal drip; Rhinorrhea; Nasal congestion Images Throat anatomy References Bachert C, Calus L, Gevaert P. Rhinosinusitis ...

  7. Electronic Health Record Systems and Intent to Apply for Meaningful Use Incentives among Office-based Physician ...

    Science.gov (United States)

    ... Order from the National Technical Information Service NCHS Electronic Health Record Systems and Intent to Apply for ... In 2011, 57% of office-based physicians used electronic medical record/electronic health record (EMR/EHR) systems, ...

  8. Aspects of space charge theory applied to dielectric under electron beam irradiation

    International Nuclear Information System (INIS)

    Oliveira, L.N. de.

    1975-01-01

    Irradiation of solid dielectric with electron beams has been used as a power full tool in investigations of charge storage and transport in such materials. Some of the results that have been obtained in this area are reviewed and the formulation of a transport equation for excess charge in irradiated insulators is dicussed. This equation is subsequently applied to various experimental set-ups. It is found that space charge effects play an essential role in the establishment of stationary currents in samples subject to quasi-penetrating electron beams. Such effects may, however, be neglected for low electron ranges. Theoretical results are in good agreement with experimental findings by Spear (1955)

  9. Zernike phase-contrast electron cryotomography applied to marine cyanobacteria infected with cyanophages.

    Science.gov (United States)

    Dai, Wei; Fu, Caroline; Khant, Htet A; Ludtke, Steven J; Schmid, Michael F; Chiu, Wah

    2014-11-01

    Advances in electron cryotomography have provided new opportunities to visualize the internal 3D structures of a bacterium. An electron microscope equipped with Zernike phase-contrast optics produces images with markedly increased contrast compared with images obtained by conventional electron microscopy. Here we describe a protocol to apply Zernike phase plate technology for acquiring electron tomographic tilt series of cyanophage-infected cyanobacterial cells embedded in ice, without staining or chemical fixation. We detail the procedures for aligning and assessing phase plates for data collection, and methods for obtaining 3D structures of cyanophage assembly intermediates in the host by subtomogram alignment, classification and averaging. Acquiring three or four tomographic tilt series takes ∼12 h on a JEM2200FS electron microscope. We expect this time requirement to decrease substantially as the technique matures. The time required for annotation and subtomogram averaging varies widely depending on the project goals and data volume.

  10. Zernike Phase Contrast Electron Cryo-Tomography Applied to Marine Cyanobacteria Infected with Cyanophages

    Science.gov (United States)

    Dai, Wei; Fu, Caroline; Khant, Htet A.; Ludtke, Steven J.; Schmid, Michael F.; Chiu, Wah

    2015-01-01

    Advances in electron cryo-tomography have provided a new opportunity to visualize the internal 3D structures of a bacterium. An electron microscope equipped with Zernike phase contrast optics produces images with dramatically increased contrast compared to images obtained by conventional electron microscopy. Here we describe a protocol to apply Zernike phase plate technology for acquiring electron tomographic tilt series of cyanophage-infected cyanobacterial cells embedded in ice, without staining or chemical fixation. We detail the procedures for aligning and assessing phase plates for data collection, and methods to obtain 3D structures of cyanophage assembly intermediates in the host, by subtomogram alignment, classification and averaging. Acquiring three to four tomographic tilt series takes approximately 12 h on a JEM2200FS electron microscope. We expect this time requirement to decrease substantially as the technique matures. Time required for annotation and subtomogram averaging varies widely depending on the project goals and data volume. PMID:25321408

  11. Applied Electronics and Optical Laboratory: an optimized practical course for comprehensive training on optics and electronics

    Science.gov (United States)

    Wang, Kaiwei; Wang, Xiaoping

    2017-08-01

    In order to enhance the practical education and hands-on experience of optoelectronics and eliminate the overlapping contents that previously existed in the experiments section adhering to several different courses, a lab course of "Applied Optoelectronics Laboratory" has been established in the College of Optical Science and Engineering, Zhejiang University. The course consists of two sections, i.e., basic experiments and project design. In section 1, basic experiments provide hands-on experience with most of the fundamental concept taught in the corresponding courses. These basic experiments including the study of common light sources such as He-Ne laser, semiconductor laser and solid laser and LED; the testing and analysis of optical detectors based on effects of photovoltaic effect, photoconduction effect, photo emissive effect and array detectors. In section 2, the course encourages students to build a team and establish a stand-alone optical system to realize specific function by taking advantage of the basic knowledge learned from section 1. Through these measures, students acquired both basic knowledge and the practical application skills. Moreover, interest in science has been developed among students.

  12. Understanding Colds: Anatomy of the Nose

    Science.gov (United States)

    ... Complications Special Features References Common Cold Understanding Colds Anatomy of the Nose The nose contains shelf-like ... white). Soft tissue, such as the eye, is gray. The maxillary sinus of adults has a volume ...

  13. Principles underlying a guideline for applying HAZOP to programmable electronic systems

    International Nuclear Information System (INIS)

    Redmill, F.; Chudleigh, M.F.; Catmur, J.R.

    1997-01-01

    This paper reports on the experience of the authors, both in applying Hazard and Operability Studies (HAZOP) to programmable electronic systems (PES) and in researching the subject. A survey during the preparation of a guideline on the application of HAZOP to PES revealed common difficulties in this application. HAZOP is introduced, the difficulties are explained, and means of overcoming them are described

  14. 21 CFR 111.30 - What requirements apply to automated, mechanical, or electronic equipment?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What requirements apply to automated, mechanical, or electronic equipment? 111.30 Section 111.30 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING...

  15. Nose profile morphology and accuracy study of nose profile estimation method in Scottish subadult and Indonesian adult populations.

    Science.gov (United States)

    Sarilita, Erli; Rynn, Christopher; Mossey, Peter A; Black, Sue; Oscandar, Fahmi

    2018-05-01

    This study investigated nose profile morphology and its relationship to the skull in Scottish subadult and Indonesian adult populations, with the aim of improving the accuracy of forensic craniofacial reconstruction. Samples of 86 lateral head cephalograms from Dundee Dental School (mean age, 11.8 years) and 335 lateral head cephalograms from the Universitas Padjadjaran Dental Hospital, Bandung, Indonesia (mean age 24.2 years), were measured. The method of nose profile estimation based on skull morphology previously proposed by Rynn and colleagues in 2010 (FSMP 6:20-34) was tested in this study. Following this method, three nasal aperture-related craniometrics and six nose profile dimensions were measured from the cephalograms. To assess the accuracy of the method, six nose profile dimensions were estimated from the three craniometric parameters using the published method and then compared to the actual nose profile dimensions.In the Scottish subadult population, no sexual dimorphism was evident in the measured dimensions. In contrast, sexual dimorphism of the Indonesian adult population was evident in all craniometric and nose profile dimensions; notably, males exhibited statistically significant larger values than females. The published method by Rynn and colleagues (FSMP 6:20-34, 2010) performed better in the Scottish subadult population (mean difference of maximum, 2.35 mm) compared to the Indonesian adult population (mean difference of maximum, 5.42 mm in males and 4.89 mm in females).In addition, regression formulae were derived to estimate nose profile dimensions based on the craniometric measurements for the Indonesian adult population. The published method is not sufficiently accurate for use on the Indonesian population, so the derived method should be used. The accuracy of the published method by Rynn and colleagues (FSMP 6:20-34, 2010) was sufficiently reliable to be applied in Scottish subadult population.

  16. Precision gamma-ray polarimetry applied to studies of bremsstrahlung produced by polarized electrons

    Energy Technology Data Exchange (ETDEWEB)

    Kovtun, Oleksiy

    2015-12-16

    The thesis reports on the measurement of bremsstrahlung linear polarization produced in collisions of longitudinally and transversely polarized electrons with gold atoms. The experiment was performed at the Mainzer Microtron MAMI in the Institut fuer Kernphysik of Johannes Gutenberg-Universitaet Mainz, Germany. Spin-oriented electrons with 2.15 MeV kinetic energy collided with a thin golden target and produced bremsstrahlung. Linear polarization of the emitted photons was measured by means of Compton polarimetry applied to a segmented high-purity germanium detector. Experimental results reveal a strong correlation between the electron spin orientation and bremsstrahlung linear polarization. This indicates a dominant role of the electron spin in atomic-field bremsstrahlung and Coulomb scattering.

  17. Application of Sensory Evaluation, HS-SPME GC-MS, E-Nose, and E-Tongue for Quality Detection in Citrus Fruits.

    Science.gov (United States)

    Qiu, Shanshan; Wang, Jun

    2015-10-01

    In this study, electronic tongue (E-tongue), headspace solid-phase microextraction gas chromatography-mass spectrometer (GC-MS), electronic nose (E-nose), and quantitative describe analysis (QDA) were applied to describe the 2 types of citrus fruits (Satsuma mandarins [Citrus unshiu Marc.] and sweet oranges [Citrus sinensis {L.} Osbeck]) and their mixing juices systematically and comprehensively. As some aroma components or some flavor molecules interacted with the whole juice matrix, the changes of most components in the fruit juice were not in proportion to the mixing ratio of the 2 citrus fruits. The potential correlations among the signals of E-tongue and E-nose, volatile components, and sensory attributes were analyzed by using analysis of variance partial least squares regression. The result showed that the variables from the sensor signals (E-tongue system and E-nose system) had significant and positive (or negative) correlations to the most variables of volatile components (GC-MS) and sensory attributes (QDA). The simultaneous utilization of E-tongue and E-nose obtained a perfect classification result with 100% accuracy rate based on linear discriminant analysis and also attained a satisfying prediction with high coefficient association for the sensory attributes (R(2) > 0.994 for training sets and R(2) > 0.983 for testing sets) and for the volatile components (R(2) > 0.992 for training sets and R(2) > 0.990 for testing sets) based on random forest. Being easy-to-use, cost-effective, robust, and capable of providing a fast analysis procedure, E-nose and E-tongue could be used as an alternative detection system to traditional analysis methods, such as GC-MS and sensory evaluation by human panel in the fruit industry. Being easy-to-use, cost-effective, robust, and capable of providing a fast analysis procedure, E-nose and E-tongue could be used as an alternative detection system to traditional analysis methods for characterizing food flavors. Based on those

  18. Analytical Performance Verification of FCS-MPC Applied to Power Electronic Converters

    DEFF Research Database (Denmark)

    Novak, Mateja; Dragicevic, Tomislav; Blaabjerg, Frede

    2017-01-01

    Since the introduction of finite control set model predictive control (FCS-MPC) in power electronics the algorithm has been missing an important aspect that would speed up its implementation in industry: a simple method to verify the algorithm performance. This paper proposes to use a statistical...... model checking (SMC) method for performance evaluation of the algorithm applied to power electronics converters. SMC is simple to implement, intuitive and it requires only an operational model of the system that can be simulated and checked against properties. Device under test for control algorithm...

  19. Effects of an applied voltage on direct interspecies electron transfer via conductive materials for methane production.

    Science.gov (United States)

    Lee, Jung-Yeol; Park, Jeong-Hoon; Park, Hee-Deung

    2017-10-01

    Direct interspecies electron transfer (DIET) between exoelectrogenic bacteria and methanogenic archaea via conductive materials is reported as an efficient method to produce methane in anaerobic organic waste digestion. A voltage can be applied to the conductive materials to accelerate the DIET between two groups of microorganisms to produce methane. To evaluate this hypothesis, two sets of anaerobic serum bottles with and without applied voltage were used with a pair of graphite rods as conductive materials to facilitate DIET. Initially, the methane production rate was similar between the two sets of serum bottles, and later the serum bottles with an applied voltage of 0.39V showed a 168% higher methane production rate than serum bottles without an applied voltage. In cyclic voltammograms, the characteristic redox peaks for hydrogen and acetate oxidation were identified in the serum bottles with an applied voltage. In the microbial community analyses, hydrogenotrophic methanogens (e.g. Methanobacterium) were observed to be abundant in serum bottles with an applied voltage, while methanogens utilizing carbon dioxide (e.g., Methanosaeta and Methanosarcina) were dominant in serum bottles without an applied voltage. Taken together, the applied voltage on conductive materials might not be effective to promote DIET in methane production. Instead, it appeared to generate a condition for hydrogenotrophic methanogenesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Electronic transport in Thue-Morse gapped graphene superlattice under applied bias

    Science.gov (United States)

    Wang, Mingjing; Zhang, Hongmei; Liu, De

    2018-04-01

    We investigate theoretically the electronic transport properties of Thue-Morse gapped graphene superlattice under an applied electric field. The results indicate that the combined effect of the band gap and the applied bias breaks the angular symmetry of the transmission coefficient. The zero-averaged wave-number gap can be greatly modulated by the band gap and the applied bias, but its position is robust against change of the band gap. Moreover, the conductance and the Fano factor are strongly dependent not only on the Fermi energy but also on the band gap and the applied bias. In the vicinity of the new Dirac point, the minimum value of the conductance obviously decreases and the Fano factor gradually forms a Poissonian value plateau with increasing of the band gap.

  1. Cough reflex sensitization from esophagus and nose.

    Science.gov (United States)

    Hennel, Michal; Brozmanova, Mariana; Kollarik, Marian

    2015-12-01

    The diseases of the esophagus and nose are among the major factors contributing to chronic cough although their role in different patient populations is debated. Studies in animal models and in humans show that afferent C-fiber activators applied on esophageal or nasal mucosa do not initiate cough, but enhance cough induced by inhaled irritants. These results are consistent with the hypothesis that activation of esophageal and nasal C-fibers contribute to cough reflex hypersensitivity observed in chronic cough patients with gastroesophageal reflux disease (GERD) and chronic rhinitis, respectively. The afferent nerves mediating cough sensitization from the esophagus are probably the neural crest-derived vagal jugular C-fibers. In addition to their responsiveness to high concentration of acid typical for gastroesophageal reflux (pH acidic reflux such as receptors highly sensitive to acid and receptors for bile acids. The nature of sensory pathways from the nose and their activators relevant for cough sensitization are less understood. Increased cough reflex sensitivity was also reported in many patients with GERD or rhinitis who do not complain of cough indicating that additional endogenous or exogenous factors may be required to develop chronic coughing in these diseases. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Discrimination between Pseudogymnoascus destructans, other dermatophytes of cave-dwelling bats, and related innocuous keratinophilic fungi based on electronic-nose/GC signatures of VOC-metabolites produced in culture

    Science.gov (United States)

    Alphus Dan Wilson; Lisa Beth Forse

    2017-01-01

    White-nose syndrome (WNS), caused by the fungal dermatophyte (Pseudogymnoascus destructans), is considered the most important disease affecting hibernating bats in North America. The identification of dermatophytic fungi, isolated from the skins of cave-dwelling bat species, is necessary to distinguish pathogenic (disease-causing) microbes from those that are innocuous...

  3. Relativistic convergent close-coupling method applied to electron scattering from mercury

    International Nuclear Information System (INIS)

    Bostock, Christopher J.; Fursa, Dmitry V.; Bray, Igor

    2010-01-01

    We report on the extension of the recently formulated relativistic convergent close-coupling (RCCC) method to accommodate two-electron and quasi-two-electron targets. We apply the theory to electron scattering from mercury and obtain differential and integrated cross sections for elastic and inelastic scattering. We compared with previous nonrelativistic convergent close-coupling (CCC) calculations and for a number of transitions obtained significantly better agreement with the experiment. The RCCC method is able to resolve structure in the integrated cross sections for the energy regime in the vicinity of the excitation thresholds for the (6s6p) 3 P 0,1,2 states. These cross sections are associated with the formation of negative ion (Hg - ) resonances that could not be resolved with the nonrelativistic CCC method. The RCCC results are compared with the experiment and other relativistic theories.

  4. Effects of Fire Suppression Agents and Weathering in the Analysis of Fire Debris by HS-MS eNose

    Directory of Open Access Journals (Sweden)

    Barbara Falatová

    2018-06-01

    Full Text Available In arson attacks the detection of ignitable liquid residues (ILRs at fire scenes provides key evidence since ignitable liquids, such as gasoline, are commonly used to initiate the fire. In most forensic laboratories gas chromatography-mass spectrometry is employed for the analysis of ILRs. When a fire occurs, suppression agents are used to extinguish the fire and, before the scene is investigated, the samples at the scene are subjected to a variety of processes such as weathering, which can significantly modify the chemical composition and thus lead to erroneous conclusions. In order to avoid this possibility, the application of chemometric tools that help the analyst to extract useful information from data is very advantageous. The study described here concerned the application of a headspace-mass spectrometry electronic nose (HS-MS eNose combined with chemometric tools to determine the presence/absence of gasoline in weathered fire debris samples. The effect of applying two suppression agents (Cafoam Aquafoam AF-6 and Pyro-chem PK-80 Powder and delays in the sampling time (from 0 to 48 h were studied. It was found that, although the suppression systems affect the mass spectra, the HS-MS eNose in combination with suitable pattern recognition chemometric tools, such as linear discriminant analysis, is able to identify the presence of gasoline in any of the studied situations (100% correct classification.

  5. Electronic bound states in parity-preserving QED3 applied to high-Tc cuprate superconductors

    International Nuclear Information System (INIS)

    Christiansen, H.R.; Cima, O.M. Del; Ferreira Junior, M.M.; Maranhao Univ., Sao Luis, MA; Helayel-Neto, J.A.; Centro Brasileiro de Pesquisas Fisicas

    2001-08-01

    We consider a parity-preserving QED 3 model with spontaneous breaking of the gauge symmetry as a framework for the evaluation of the electron-electron interaction potential underlying high-T e superconductivity. The fact that resulting potential, - C s K o (Mr), is non-confining and weak (in the sense of Kato) strongly suggests the mechanism of pair-condensation. This potential, compatible with an s-wave order parameters, is then applied to the Schrodinger equation for the sake of numerical calculations, thereby enforcing the existence of bound states. The results worked out by means of our theoretical framework are checked by considering a number of phenomenological data extracted from different copper oxide superconductors. The agreement may motivate a deeper analysis of our model viewing an application to quasi-planar cuprate superconductors. The data analyzed here suggest an energy scale of 1-10 meV for the breaking of the U(1)-symmetry. (author)

  6. Electron transport in fast dielectric liquids at high applied electric fields

    International Nuclear Information System (INIS)

    Faidas, H.; McCorkle, D.L.

    1990-01-01

    The drift velocity, w, of excess electrons as a function of the applied uniform electric field, E, in liquid 2,2-dimethylpropane (TMC), tetramethylsilane (TMS), tetramethylgermanium (TMG), tetramethyltin (TMT), 2,2,4,4-tetramethylpentane (TMP) and in mixtures of TMS with TMP (mole ratio M = 1.31/1) and n-pentane (M = 102/1, 17/1, and 5.6/1) has been measured for E-values up to ∼10 5 V cm -1 . The thermal electron mobility in the above liquids is 71.5, 119.3, 114.7, 85.7, 31.8, 39.1, 118, 85, and 47.6 cm 2 s -1 V -1 , respectively. 8 refs., 2 figs., 1 tab

  7. Experimental Route to Scanning Probe Hot Electron Nanoscopy (HENs) Applied to 2D Material

    KAUST Repository

    Giugni, Andrea

    2017-06-09

    This paper presents details on a new experimental apparatus implementing the hot electron nanoscopy (HENs) technique introduced for advanced spectroscopies on structure and chemistry in few molecules and interface problems. A detailed description of the architecture used for the laser excitation of surface plasmons at an atomic force microscope (AFM) tip is provided. The photogenerated current from the tip to the sample is detected during the AFM scan. The technique is applied to innovative semiconductors for applications in electronics: 2D MoS2 single crystal and a p-type SnO layer. Results are supported by complementary scanning Kelvin probe microscopy, traditional conductive AFM, and Raman measurements. New features highlighted by HEN technique reveal details of local complexity in MoS2 and polycrystalline structure of SnO at nanometric scale otherwise undetected. The technique set in this paper is promising for future studies in nanojunctions and innovative multilayered materials, with new insight on interfaces.

  8. Caudal Septal Stabilization Suturing Technique to Treat Crooked Noses.

    Science.gov (United States)

    Baykal, Bahadir; Erdim, Ibrahim; Guvey, Ali; Oghan, Fatih; Kayhan, Fatma Tulin

    2016-10-01

    To rotate the nasal axis and septum to the midline using an L-strut graft and a novel caudal septal stabilization suturing technique to treat crooked noses. Thirty-six patients were included in the study. First, an L-strut graft was prepared by excising the deviated cartilage site in all patients. Second, multiple stabilization suturing, which we describe as a caudal septal stabilization suturing technique with a "fishing net"-like appearance, was applied between the anterior nasal spine and caudal septum in all patients. This new surgical technique, used to rotate the caudal septum, was applied to 22 I-type and 14 C-type crooked noses. Correction rates for the crooked noses were compared between the 2 inclination types with angular estimations. Deviation angles were measured using the AutoCAD 2012 software package and frontal (anterior) views, with the Frankfurt horizontal line parallel to the ground. Nasal axis angles showing angle improvement graded 4 categories as excellent, good, acceptable, and unsuccessful for evaluations at 6 months after surgery in the study. The success rate in the C-type nasal inclination was 86.7% (±21.9) and 88% (±16.7) in the I-type. The overall success rate of L-strut grafting and caudal septal stabilization suturing in crooked nose surgeries was 87.5% (±18.6). "Unsuccessful" results were not reported in any of the patients. L-strut grafting and caudal septal stabilization suturing techniques are efficacious in crooked noses according to objective measurement analysis results. However, a longer follow-up duration in a larger patient population is needed.

  9. 3D scanning electron microscopy applied to surface characterization of fluorosed dental enamel.

    Science.gov (United States)

    Limandri, Silvina; Galván Josa, Víctor; Valentinuzzi, María Cecilia; Chena, María Emilia; Castellano, Gustavo

    2016-05-01

    The enamel surfaces of fluorotic teeth were studied by scanning electron stereomicroscopy. Different whitening treatments were applied to 25 pieces to remove stains caused by fluorosis and their surfaces were characterized by stereomicroscopy in order to obtain functional and amplitude parameters. The topographic features resulting for each treatment were determined through these parameters. The results obtained show that the 3D reconstruction achieved from the SEM stereo pairs is a valuable potential alternative for the surface characterization of this kind of samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Applied nursing informatics research - state-of-the-art methodologies using electronic health record data.

    Science.gov (United States)

    Park, Jung In; Pruinelli, Lisiane; Westra, Bonnie L; Delaney, Connie W

    2014-01-01

    With the pervasive implementation of electronic health records (EHR), new opportunities arise for nursing research through use of EHR data. Increasingly, comparative effectiveness research within and across health systems is conducted to identify the impact of nursing for improving health, health care, and lowering costs of care. Use of EHR data for this type of research requires use of national and internationally recognized nursing terminologies to normalize data. Research methods are evolving as large data sets become available through EHRs. Little is known about the types of research and analytic methods for applied to nursing research using EHR data normalized with nursing terminologies. The purpose of this paper is to report on a subset of a systematic review of peer reviewed studies related to applied nursing informatics research involving EHR data using standardized nursing terminologies.

  11. Electronics department progress report. Basic and applied research activity 1975-1977

    International Nuclear Information System (INIS)

    1978-10-01

    The electronics department at Risoe National Laboratory, Denmark, comprises about 80 people and is made up of essentially two main divisions. One deals with the provision of instrumentation and measurement expertise for the different groups at Risoe who conduct basic research or technological R and D. This division employs a group of scientific electronics consultants, a production group, a maintenance facility and a central instrument pool for the complete site. The other division, whose work is reported here, is engaged in both basic and applied research in topics and areas of direct interest to the department itself. These involve the development and evaluation of methods, for example, in the field of plant reliability and safety as well as in a group engaged in nuclear geophysical activities - including mineral prospecting in Greenland. Another team is working with man-machine problems in highly automated systems and the associated needs for computer support in connection with proper job allocation and design. Finally, a group is active in the field of applied laser physics. The time period covered is 1975-1977. (author/BP)

  12. Method for pulse to pulse dose reproducibility applied to electron linear accelerators

    International Nuclear Information System (INIS)

    Ighigeanu, D.; Martin, D.; Oproiu, C.; Cirstea, E.; Craciun, G.

    2002-01-01

    An original method for obtaining programmed beam single shots and pulse trains with programmed pulse number, pulse repetition frequency, pulse duration and pulse dose is presented. It is particularly useful for automatic control of absorbed dose rate level, irradiation process control as well as in pulse radiolysis studies, single pulse dose measurement or for research experiments where pulse-to-pulse dose reproducibility is required. This method is applied to the electron linear accelerators, ALIN-10 of 6.23 MeV and 82 W and ALID-7, of 5.5 MeV and 670 W, built in NILPRP. In order to implement this method, the accelerator triggering system (ATS) consists of two branches: the gun branch and the magnetron branch. ATS, which synchronizes all the system units, delivers trigger pulses at a programmed repetition rate (up to 250 pulses/s) to the gun (80 kV, 10 A and 4 ms) and magnetron (45 kV, 100 A, and 4 ms).The accelerated electron beam existence is determined by the electron gun and magnetron pulses overlapping. The method consists in controlling the overlapping of pulses in order to deliver the beam in the desired sequence. This control is implemented by a discrete pulse position modulation of gun and/or magnetron pulses. The instabilities of the gun and magnetron transient regimes are avoided by operating the accelerator with no accelerated beam for a certain time. At the operator 'beam start' command, the ATS controls electron gun and magnetron pulses overlapping and the linac beam is generated. The pulse-to-pulse absorbed dose variation is thus considerably reduced. Programmed absorbed dose, irradiation time, beam pulse number or other external events may interrupt the coincidence between the gun and magnetron pulses. Slow absorbed dose variation is compensated by the control of the pulse duration and repetition frequency. Two methods are reported in the electron linear accelerators' development for obtaining the pulse to pulse dose reproducibility: the method

  13. 21 CFR 868.6225 - Nose clip.

    Science.gov (United States)

    2010-04-01

    ... ANESTHESIOLOGY DEVICES Miscellaneous § 868.6225 Nose clip. (a) Identification. A nose clip is a device intended to close a patient's external nares (nostrils) during diagnostic or therapeutic procedures. (b... from the current good manufacturing practice requirements of the quality system regulation in part 820...

  14. Method to integrate clinical guidelines into the electronic health record (EHR) by applying the archetypes approach.

    Science.gov (United States)

    Garcia, Diego; Moro, Claudia Maria Cabral; Cicogna, Paulo Eduardo; Carvalho, Deborah Ribeiro

    2013-01-01

    Clinical guidelines are documents that assist healthcare professionals, facilitating and standardizing diagnosis, management, and treatment in specific areas. Computerized guidelines as decision support systems (DSS) attempt to increase the performance of tasks and facilitate the use of guidelines. Most DSS are not integrated into the electronic health record (EHR), ordering some degree of rework especially related to data collection. This study's objective was to present a method for integrating clinical guidelines into the EHR. The study developed first a way to identify data and rules contained in the guidelines, and then incorporate rules into an archetype-based EHR. The proposed method tested was anemia treatment in the Chronic Kidney Disease Guideline. The phases of the method are: data and rules identification; archetypes elaboration; rules definition and inclusion in inference engine; and DSS-EHR integration and validation. The main feature of the proposed method is that it is generic and can be applied toany type of guideline.

  15. 1st International Conference on Opto-Electronics and Applied Optics

    CERN Document Server

    Bhattacharya, Indrani

    2015-01-01

    The Proceedings of First International Conference on Opto-Electronics and Applied Optics 2014, IEM OPTRONIX 2014 presents the research contributions presented in the conference by researchers from both India and abroad. Contributions from established scientists as well as students are included. The book is organized to enable easy access to various topics of interest.   The first part includes the Keynote addresses by Phillip Russell, Max Planck Institute of the Light Sciences, Erlangen, Germany and Lorenzo Pavesi, University of Trento, Italy.   The second part focuses on the Plenary Talks given by eminent scientists, namely, Azizur Rahman, City University London, London; Bishnu Pal, President, The Optical Society of India; Kamakhya Ghatak, National Institute of Technology, Agartala; Kehar Singh, Former Professor, India Institute of Technology Delhi; Mourad Zghal, SUPCOM, University of Carthage, Tunisia; Partha Roy Chaudhuri, IIT Kharagpur; S K. Bhadra, CSIR-Central Glass and Ceramic Research Institute, Kol...

  16. Conduction band structure and electron mobility in uniaxially strained Si via externally applied strain in nanomembranes

    Energy Technology Data Exchange (ETDEWEB)

    Chen Feng [Xi' an Jiaotong University, Xi' an, Shaanxi 710049 (China); Euaruksakul, Chanan; Himpsel, F J; Lagally, Max G [University of Wisconsin-Madison, Madison, WI 53706 (United States); Liu Zheng; Liu Feng, E-mail: lagally@engr.wisc.edu [University of Utah, Salt Lake City, UT 84112 (United States)

    2011-08-17

    Strain changes the band structure of semiconductors. We use x-ray absorption spectroscopy to study the change in the density of conduction band (CB) states when silicon is uniaxially strained along the [1 0 0] and [1 1 0] directions. High stress can be applied to silicon nanomembranes, because their thinness allows high levels of strain without fracture. Strain-induced changes in both the sixfold degenerate {Delta} valleys and the eightfold degenerate L valleys are determined quantitatively. The uniaxial deformation potentials of both {Delta} and L valleys are directly extracted using a strain tensor appropriate to the boundary conditions, i.e., confinement in the plane in the direction orthogonal to the straining direction, which correspond to those of strained CMOS in commercial applications. The experimentally determined deformation potentials match the theoretical predictions well. We predict electron mobility enhancement created by strain-induced CB modifications.

  17. Fatigue damage behavior of a surface-mount electronic package under different cyclic applied loads

    Science.gov (United States)

    Ren, Huai-Hui; Wang, Xi-Shu

    2014-04-01

    This paper studies and compares the effects of pull-pull and 3-point bending cyclic loadings on the mechanical fatigue damage behaviors of a solder joint in a surface-mount electronic package. The comparisons are based on experimental investigations using scanning electron microscopy (SEM) in-situ technology and nonlinear finite element modeling, respectively. The compared results indicate that there are different threshold levels of plastic strain for the initial damage of solder joints under two cyclic applied loads; meanwhile, fatigue crack initiation occurs at different locations, and the accumulation of equivalent plastic strain determines the trend and direction of fatigue crack propagation. In addition, simulation results of the fatigue damage process of solder joints considering a constitutive model of damage initiation criteria for ductile materials and damage evolution based on accumulating inelastic hysteresis energy are identical to the experimental results. The actual fatigue life of the solder joint is almost the same and demonstrates that the FE modeling used in this study can provide an accurate prediction of solder joint fatigue failure.

  18. Electronic Patient Reported Outcomes in Paediatric Oncology - Applying Mobile and Near Field Communication Technology.

    Science.gov (United States)

    Duregger, Katharina; Hayn, Dieter; Nitzlnader, Michael; Kropf, Martin; Falgenhauer, Markus; Ladenstein, Ruth; Schreier, Günter

    2016-01-01

    Electronic Patient Reported Outcomes (ePRO) gathered using telemonitoring solutions might be a valuable source of information in rare cancer research. The objective of this paper was to develop a concept and implement a prototype for introducing ePRO into the existing neuroblastoma research network by applying Near Field Communication and mobile technology. For physicians, an application was developed for registering patients within the research network and providing patients with an ID card and a PIN for authentication when transmitting telemonitoring data to the Electronic Data Capture system OpenClinica. For patients, a previously developed telemonitoring system was extended by a Simple Object Access Protocol (SOAP) interface for transmitting nine different health parameters and toxicities. The concept was fully implemented on the front-end side. The developed application for physicians was prototypically implemented and the mobile application of the telemonitoring system was successfully connected to OpenClinica. Future work will focus on the implementation of the back-end features.

  19. Laser generated hot electron transport in an externally applied magnetic field

    International Nuclear Information System (INIS)

    Burnett, N.H.; Enright, G.D.

    1986-01-01

    The authors have investigated the effect of an externally applied DC magnetic field on the generation and transport of hot electrons in CO/sub 2/ laser irradiation of cylindrical targets. The targets used in these studies were 6.3 mm diameter metal rods through which a pulsed current was driven from an external capacitor. Magnetic fields up to 150 kgauss were produced at the target surface. The CO/sub 2/ laser was focused with an f/5 lens resulting in a laser intensity of ≅3 x 10/sup 14/ W/cm/sup 2/ in a 100 μm diameter focal spot. The effect of the external magnetic field on the generation and inward transport of superhot (≥ 100 keV) electrons was studied. Principal diagnostics included a six channel hard x-ray spectrometer, a high energy x-ray pinhole camera, a LiF Laue x-ray spectrograph and a Ross-filtered (W-Ta) pair of x-ray detectors. The latter two diagnostics were designed to detect Au Kα /sub emission at 68.2 keV

  20. Projection-reduction method applied to deriving non-linear optical conductivity for an electron-impurity system

    Directory of Open Access Journals (Sweden)

    Nam Lyong Kang

    2013-07-01

    Full Text Available The projection-reduction method introduced by the present authors is known to give a validated theory for optical transitions in the systems of electrons interacting with phonons. In this work, using this method, we derive the linear and first order nonlinear optical conductivites for an electron-impurity system and examine whether the expressions faithfully satisfy the quantum mechanical philosophy, in the same way as for the electron-phonon systems. The result shows that the Fermi distribution function for electrons, energy denominators, and electron-impurity coupling factors are contained properly in organized manners along with absorption of photons for each electron transition process in the final expressions. Furthermore, the result is shown to be represented properly by schematic diagrams, as in the formulation of electron-phonon interaction. Therefore, in conclusion, we claim that this method can be applied in modeling optical transitions of electrons interacting with both impurities and phonons.

  1. Electronic speckle-pattern interferometry (ESPI) applied to the study of mechanical behavior of human jaws

    Science.gov (United States)

    Roman, Juan F.; Moreno de las Cuevas, Vincente; Salgueiro, Jose R.; Suarez, David; Fernandez, Paula; Gallas, Mercedes; Blanchard, Alain

    1996-01-01

    The study of the mechanical behavior of the human jaw during chewing is helpful in several specific medical fields that cover the maxillo-facial area. In this work, electronic speckle pattern interferometry has been applied to study dead jaw bones under external stress which simulates the deformations induced during chewing. Fringes obtained after subtraction of two images of the jaw, the image of the relaxed jaw and that of the jaw under stress, give us information about the most stressed zones. The interferometric analysis proposed here is attractive as it can be done in real time with the jaw under progressive stress. Image processing can be applied for improving the quality of fringes. This research can be of help in orthognathic surgery, for example in diagnosis and treatment of fractured jaws, in oral surgery, and in orthodontics because it would help us to know the stress dispersion when we insert an osseointegrated implant or place an orthodontic appliance, respectively. Studying fragments of human jaw some results about its elasticity and flexibility were obtained.

  2. Application of nose smear method to the assessment of internal contamination

    International Nuclear Information System (INIS)

    Miyabe, K.; Ishiguro, H.; Nakata, K.; Fukuda, S.

    1985-01-01

    At PNC Tokai Works, the plutonium fuel fabrication facility has been operating since 1967. Lung counting and bioassay for urine are performed routinely for internal radiation dosimetry in this facility. The nose smear method is used for assessing the significance of intake whenever an incident involving inhalation of radioactive material occurs. It was found empirically on the basis of 22 inhalation cases that nose smear samples were useful for assessing tentatively the intake in an incidental inhalation of plutonium aerosol. In 80% of the cases of plutonium inhalation, the amount in the early faecal excretion (5 days after inhalation) is less than 10 times the plutonium in the nose smear samples over the activity region from 0.074 to 28 Bq of nose smear samples. It is suggested that the amount of plutonium in early excreted faeces be estimated by applying the factor of 10 to the activity in nose smear samples. As an example, when PuO 2 (class Y, AMAD 1 μm) 0.074 Bq corresponding to the minimum detectable amount is measured in the nose smear samples, the early faecal excretion and the total intake can be estimated approximately to be 0.74 Bq and 1.55 Bq, respectively, applying the clearance model of ICRP 30, and the committed dose equivalent of bone surface is estimated as 1.6 mSv. (author)

  3. Investigation on the energy spectrums of electrons in atmospheric pressure argon plasma jets and their dependences on the applied voltage

    Science.gov (United States)

    Chen, Xinxian; Tan, Zhenyu; Liu, Yadi; Li, Xiaotong; Pan, Jie; Wang, Xiaolong

    2017-08-01

    This work presents a systematical investigation on the spatiotemporal evolution of the energy spectrum of electrons in atmospheric pressure argon plasma jets and its dependence on the applied voltage. The investigations are carried out by means of the numerical simulation based on a particle-in-cell Monte-Carlo collision model. The characteristics of the spatiotemporal evolution of the energy spectrum of electrons (ESE) in the discharge space have been presented, and especially the mechanisms of inducing these characteristics have also been revealed. The present work shows the following conclusions. In the evolution of ESE, there is a characteristic time under each applied voltage. Before the characteristic time, the peak value of ESE decreases, the peak position shifts toward high energy, and the distribution of ESE becomes wider and wider, but the reverse is true after the characteristic time. The formation of these characteristics can be mainly attributed to the transport of electrons toward a low electric field as well as a balance between the energy gained from the electric field including the effect of space charges and the energy loss due to inelastic collisions in the process of electron transport. The characteristic time decreases with the applied voltage. In addition, the average energy of electrons at the characteristic time can be increased by enhancing the applied voltage. The results presented in this work are of importance for regulating and controlling the energy of electrons in the plasma jets applied to plasma medicine.

  4. 3rd International Conference on Opto-Electronics and Applied Optics

    CERN Document Server

    Chakrabarti, Satyajit; Reehal, Haricharan; Lakshminarayanan, Vasudevan

    2017-01-01

    The Proceedings of 3rd International Conference on Opto-Electronics and Applied Optics, OPTRONIX 2016 is an effort to promote and present the research works by scientists and researchers including students in India and abroad in the area of Green Photonics and other related areas as well as to raise awareness about the recent trends of research and development in the area of the related fields. The book has been organized in such a way that it will be easier for the readers to go through and find out the topic of their interests. The first part includes the Keynote addresses by Rajesh Gupta, Department of Energy Science and Engineering, Indian Institute of Technology, Bombay; P.T. Ajith Kumar, President and Leading Scientist Light Logics Holography and Optics, Crescent Hill, Trivandrum, Kerala; and K.K. Ghosh, Institute of Engineering & Management, Kolkata, India.  The second part focuses on the Plenary and Invited Talks given by eminent scientists namely, Vasudevan Lakshminarayanan, University of Wate...

  5. White-Nose Syndrome of bats

    Science.gov (United States)

    Jessie A. Glaeser; Martin J. Pfeiffer; Daniel L. Lindner

    2016-01-01

    Devastating. Catastrophic. Unprecedented. This is how white-nose syndrome of bats (WNS) is characterized. It is one of the deadliest wildlife diseases ever observed and could have significant impacts on outdoor recreation, agriculture and wildlife management.

  6. Your Nose, the Guardian of Your Lungs

    Science.gov (United States)

    ... more susceptible to germs and pollens. Many anti-anxiety medications also have a drying effect on the nose and throat. Birth control pills, blood pressure medicines called beta-blockers, and Viagra can cause increased nasal congestion. Eye ...

  7. Final Aperture Superposition Technique applied to fast calculation of electron output factors and depth dose curves

    International Nuclear Information System (INIS)

    Faddegon, B.A.; Villarreal-Barajas, J.E.

    2005-01-01

    The Final Aperture Superposition Technique (FAST) is described and applied to accurate, near instantaneous calculation of the relative output factor (ROF) and central axis percentage depth dose curve (PDD) for clinical electron beams used in radiotherapy. FAST is based on precalculation of dose at select points for the two extreme situations of a fully open final aperture and a final aperture with no opening (fully shielded). This technique is different than conventional superposition of dose deposition kernels: The precalculated dose is differential in position of the electron or photon at the downstream surface of the insert. The calculation for a particular aperture (x-ray jaws or MLC, insert in electron applicator) is done with superposition of the precalculated dose data, using the open field data over the open part of the aperture and the fully shielded data over the remainder. The calculation takes explicit account of all interactions in the shielded region of the aperture except the collimator effect: Particles that pass from the open part into the shielded part, or visa versa. For the clinical demonstration, FAST was compared to full Monte Carlo simulation of 10x10,2.5x2.5, and 2x8 cm 2 inserts. Dose was calculated to 0.5% precision in 0.4x0.4x0.2 cm 3 voxels, spaced at 0.2 cm depth intervals along the central axis, using detailed Monte Carlo simulation of the treatment head of a commercial linear accelerator for six different electron beams with energies of 6-21 MeV. Each simulation took several hours on a personal computer with a 1.7 Mhz processor. The calculation for the individual inserts, done with superposition, was completed in under a second on the same PC. Since simulations for the pre calculation are only performed once, higher precision and resolution can be obtained without increasing the calculation time for individual inserts. Fully shielded contributions were largest for small fields and high beam energy, at the surface, reaching a maximum

  8. Nosing Around: Play in Pigs

    Directory of Open Access Journals (Sweden)

    Kristina Horback

    2014-05-01

    Full Text Available The predominant method of measuring welfare in swine focuses on overt physical ailments, such as skin lesions, lameness, and body condition. An alternative metric for assessing welfare in swine can be to measure the frequency and duration of positive behavioral states, such as play. Given that play occurs only when an animal's primary needs (food, comfort, safety, etc. have been satisfied, it has been suggested that play may be a sensitive indicator for assessing the welfare of non-human animals. Play has primarily been described in young piglets and is assessed via the occurrence of specific play markers. These play markers include overt bursts of energy like scamper, or more subtle social behaviors like nose-to-body contact. This review describes four areas of play for swine: locomotor, object, sow-piglet, and, peer play. From sporadic leaping to combative wrestling, play behavior allows for the fine-tuning of reflexive behavior which can enhance physical development, enrich cognitive abilities, and facilitate the maintenance of social bonds.

  9. How does nose blowing effect the computed tomography of paranasal sinuses in chronic sinusitis?

    Energy Technology Data Exchange (ETDEWEB)

    Savranlar, Ahmet; Uzun, Lokman; Ugur, Mehmet Birol; Mahmutyazicioglu, Kamran; Ozer, Tulay; Gundogdu, Sadi

    2005-02-01

    Objective: Our aim was to determine whether inward or outward movement of the secretions in the paranasal sinuses due to nose blowing after nasal decongestion has any effect on the paranasal sinus computed tomography (CT) images in patients with sinusitis and to asses whether nose blowing may result in misdiagnosis or overdiagnosis in radiological evaluation of sinusitis. Materials and methods: Twenty-four patients with chronic sinusitis were evaluated in an academic tertiary care hospital and data were collected prospectively. After coronal sinus computed tomography scans were performed at 100 mA setting which was half the value of the standard radiation dose suggested by the manufacturer, topical decongestion was applied to each nostril followed by nose blowing 10 min later. Sinus CT scans were then repeated at the same setting. We evaluated the mucosal thickness of medial, lateral, superior and inferior maxillary and frontal sinus walls and the maximal thickness in anterior ethmoidal cells. The measurements prior to and following nose blowing were compared with Wilcoxon signed ranks test. The obtained images were also staged using Lund-McKay staging system separately and the scores were compared with Student's t-test. Results: We observed a tendency towards reduction in mucosal thickness after nose blowing. There were statistically significant differences between maxillary sinus inferior wall and frontal sinus inferior wall mucosal thickness values prior to and after nose blowing. The difference however was very small, about 0.5 mm in magnitude and Lund-McKay score did not change in any of the patients after nose blowing. Conclusion: Nose blowing and topical nasal decongestion does not have any effect on the diagnostic accuracy of sinus CT in chronic sinusitis patients.

  10. How does nose blowing effect the computed tomography of paranasal sinuses in chronic sinusitis?

    International Nuclear Information System (INIS)

    Savranlar, Ahmet; Uzun, Lokman; Ugur, Mehmet Birol; Mahmutyazicioglu, Kamran; Ozer, Tulay; Gundogdu, Sadi

    2005-01-01

    Objective: Our aim was to determine whether inward or outward movement of the secretions in the paranasal sinuses due to nose blowing after nasal decongestion has any effect on the paranasal sinus computed tomography (CT) images in patients with sinusitis and to asses whether nose blowing may result in misdiagnosis or overdiagnosis in radiological evaluation of sinusitis. Materials and methods: Twenty-four patients with chronic sinusitis were evaluated in an academic tertiary care hospital and data were collected prospectively. After coronal sinus computed tomography scans were performed at 100 mA setting which was half the value of the standard radiation dose suggested by the manufacturer, topical decongestion was applied to each nostril followed by nose blowing 10 min later. Sinus CT scans were then repeated at the same setting. We evaluated the mucosal thickness of medial, lateral, superior and inferior maxillary and frontal sinus walls and the maximal thickness in anterior ethmoidal cells. The measurements prior to and following nose blowing were compared with Wilcoxon signed ranks test. The obtained images were also staged using Lund-McKay staging system separately and the scores were compared with Student's t-test. Results: We observed a tendency towards reduction in mucosal thickness after nose blowing. There were statistically significant differences between maxillary sinus inferior wall and frontal sinus inferior wall mucosal thickness values prior to and after nose blowing. The difference however was very small, about 0.5 mm in magnitude and Lund-McKay score did not change in any of the patients after nose blowing. Conclusion: Nose blowing and topical nasal decongestion does not have any effect on the diagnostic accuracy of sinus CT in chronic sinusitis patients

  11. Suppression of beam-excited electron waves by an externally applied RF signal

    International Nuclear Information System (INIS)

    Fukumasa, Osamu; Itatani, Ryohei

    1980-11-01

    Suppression of the beam-excited electron wave in a bounded system is investigated in connection with the beam distribution function. Wave suppression has two different processes depending on whether injected beams are reflected at the other end or not. In the absence of reflected beam electrons, deformation of the beam distribution function is observed in relation to the suppression of the electron wave. However, when beam electrons are reflected, the external wave suppresses the electron wave but distribution function shows no appreciable change. These experimental results show that nonlinear behaviors of beam electrons, namely behaviors of reflected beams, are quite important for wave suppression. By using the method of partial simulation, interaction between two waves in the bounded system including nonlinear motions of beam electrons is studied numerically. Qualitative agreement between experimental and numerical results is obtained. (author)

  12. Advanced Electron Holography Applied to Electromagnetic Field Study in Materials Science.

    Science.gov (United States)

    Shindo, Daisuke; Tanigaki, Toshiaki; Park, Hyun Soon

    2017-07-01

    Advances and applications of electron holography to the study of electromagnetic fields in various functional materials are presented. In particular, the development of split-illumination electron holography, which introduces a biprism in the illumination system of a holography electron microscope, enables highly accurate observations of electromagnetic fields and the expansion of the observable area. First, the charge distributions on insulating materials were studied by using split-illumination electron holography and including a mask in the illumination system. Second, the three-dimensional spin configurations of skyrmion lattices in a helimagnet were visualized by using a high-voltage holography electron microscope. Third, the pinning of the magnetic flux lines in a high-temperature superconductor YBa 2 Cu 3 O 7-y was analyzed by combining electron holography and scanning ion microscopy. Finally, the dynamic accumulation and collective motions of electrons around insulating biomaterial surfaces were observed by utilizing the amplitude reconstruction processes of electron holography. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Digitisation of electron microscope films: Six useful tests applied to three film scanners

    International Nuclear Information System (INIS)

    Henderson, R.; Cattermole, D.; McMullan, G.; Scotcher, S.; Fordham, M.; Amos, W.B.; Faruqi, A.R.

    2007-01-01

    A series of simple tests have been used to measure the performance of flat-bed film scanners suitable for digitisation of electron micrographs. Two of the film scanners evaluated are commercially available and one has been constructed in the laboratory paying special attention to the needs of the electron microscopist. The tests may be useful for others

  14. The general particle tracer code applied to the fusion free-electron maser

    NARCIS (Netherlands)

    de Loos, M. J.; van der Geer, S. B.; van der Geer, C. A. J.; Verhoeven, A. G. A.; Urbanus, W. H.

    1998-01-01

    The fusion Free-Electron Maser (FEM) is the prototype of a high power, electrostatic mm-wave source, tunable in the range 130-260 GHz. In order to achieve a high overall efficiency, the charge and energy of the spent electron beam, i.e. the beam which leaves the undulator after interaction with the

  15. Non-linear effects in electron cyclotron current drive applied for the stabilization of neoclassical tearing modes

    NARCIS (Netherlands)

    Ayten, B.; Westerhof, E.; ASDEX Upgrade team,

    2014-01-01

    Due to the smallness of the volumes associated with the flux surfaces around the O-point of a magnetic island, the electron cyclotron power density applied inside the island for the stabilization of neoclassical tearing modes (NTMs) can exceed the threshold for non-linear effects as derived

  16. A new standardless quantitative electron probe microanalysis technique applied to III-V compound semiconductors

    International Nuclear Information System (INIS)

    Zangalis, K.P.; Christou, A.

    1982-01-01

    The present paper introduces a new standardless quantitative scheme for off-line electron microprobe analysis applications. The analysis is based on standard equations of the type Isub(i)=Csub(i)fsub(ZAF)βsub(i) and is specifically suitable for compound semiconductors. The roots to the resultant nth-degree polynomial are the unknown concentrations. Methods for computing Csub(i) when coefficients βsub(i) are unknown are also outlined. Applications of standardless analysis to GaAs and InP specimens are compared with results obtained by Auger electron spectroscopy and quantitative electron probe analysis with standards. (Auth.)

  17. 3D invariant embedding model for backscattering electrons applied to materials characterization

    International Nuclear Information System (INIS)

    Figueroa, C.; Nieva, N.; Heluani, S.P.

    2007-01-01

    In this work, the results of a 3D model used to describe the fraction of backscattered electrons, together with its energy and angular distributions, are reported. This 3D model is the result of improvements in the Invariant Embedding Approach to Microanalysis (IEAM). Comparisons with experiment show that the theoretical results follow the general trend of experimental data, when parameters (such as atomic number, energy of the impinging electrons and tilted angle) are changed

  18. Universal FFM Hydrogen Spectral Line Shapes Applied to Ions and Electrons

    Science.gov (United States)

    Mossé, C.; Calisti, A.; Ferri, S.; Talin, B.; Bureyeva, L. A.; Lisitsa, V. S.

    2008-10-01

    We present a method for the calculation of hydrogen spectral line shapes based on two combined approaches: Universal Model and FFM procedure. We start with the analytical functions for the intensities of the Stark components of radiative transitions between highly excited atomic states with large values of principal quantum numbers n,n'γ1, with Δn = n-n'≪n for the specific cases of Hn-α line (Δn = 1) and Hn-β line (Δn = 2). The FFM line shape is obtained by averaging on the electric field of the Hooper's field distribution for ion and electron perturber dynamics and by mixing the Stark components with a jumping frequency rate ve (vi) where v = N1/3u (N is electron density and u is the ion or electron thermal velocity). Finally, the total line shape is given by convolution of ion and electron line shapes. Hydrogen line shape calculations for Balmer Hα and Hβ lines are compared to experimental results in low density plasma (Ne˜1016-1017cm-3) and low electron temperature in order of 10 000K. This method relying on analytic expressions permits fast calculation of Hn-α and Hn-β lines of hydrogen and could be used in the study of the Stark broadening of radio recombination lines for high principal quantum number.

  19. The virtual nose: a 3-dimensional virtual reality model of the human nose.

    Science.gov (United States)

    Vartanian, A John; Holcomb, Joi; Ai, Zhuming; Rasmussen, Mary; Tardy, M Eugene; Thomas, J Regan

    2004-01-01

    The 3-dimensionally complex interplay of soft tissue, cartilaginous, and bony elements makes the mastery of nasal anatomy difficult. Conventional methods of learning nasal anatomy exist, but they often involve a steep learning curve. Computerized models and virtual reality applications have been used to facilitate teaching in a number of other complex anatomical regions, such as the human temporal bone and pelvic floor. We present a 3-dimensional (3-D) virtual reality model of the human nose. Human cadaveric axial cross-sectional (0.33-mm cuts) photographic data of the head and neck were used. With 460 digitized images, individual structures were traced and programmed to create a computerized polygonal model of the nose. Further refinements to this model were made using a number of specialized computer programs. This 3-D computer model of the nose was then programmed to operate as a virtual reality model. Anatomically correct 3-D model of the nose was produced. High-resolution images of the "virtual nose" demonstrate the nasal septum, lower lateral cartilages, middle vault, bony dorsum, and other structural details of the nose. Also, the model can be combined with a separate virtual reality model of the face and its skin cover as well as the skull. The user can manipulate the model in space, examine 3-D anatomical relationships, and fade superficial structures to reveal deeper ones. The virtual nose is a 3-D virtual reality model of the nose that is accurate and easy to use. It can be run on a personal computer or in a specialized virtual reality environment. It can serve as an effective teaching tool. As the first virtual reality model of the nose, it establishes a virtual reality platform from which future applications can be launched.

  20. Rapid Identification of Asteraceae Plants with Improved RBF-ANN Classification Models Based on MOS Sensor E-Nose

    Directory of Open Access Journals (Sweden)

    Hui-Qin Zou

    2014-01-01

    Full Text Available Plants from Asteraceae family are widely used as herbal medicines and food ingredients, especially in Asian area. Therefore, authentication and quality control of these different Asteraceae plants are important for ensuring consumers’ safety and efficacy. In recent decades, electronic nose (E-nose has been studied as an alternative approach. In this paper, we aim to develop a novel discriminative model by improving radial basis function artificial neural network (RBF-ANN classification model. Feature selection algorithms, including principal component analysis (PCA and BestFirst + CfsSubsetEval (BC, were applied in the improvement of RBF-ANN models. Results illustrate that in the improved RBF-ANN models with lower dimension data classification accuracies (100% remained the same as in the original model with higher-dimension data. It is the first time to introduce feature selection methods to get valuable information on how to attribute more relevant MOS sensors; namely, in this case, S1, S3, S4, S6, and S7 show better capability to distinguish these Asteraceae plants. This paper also gives insights to further research in this area, for instance, sensor array optimization and performance improvement of classification model.

  1. Analysis of disturbances in a hypersonic boundary layer on a cone with heating/cooling of the nose tip

    Science.gov (United States)

    Bountin, Dmitry; Maslov, Anatoly; Gromyko, Yury

    2018-05-01

    Experimental results of the influence of local heating/cooling on the development of hypersonic boundary layer disturbances are reported. Local heating/cooling is applied at the cone nose tip. The experiments are carried out at the Mach number M = 5.95, stagnation temperature T0 = 360-418 K, and stagnation pressure P0 = 3.7-45 atm. The unit Reynolds number is varied in the interval Re1 = (4.5-63) × 106 m-1. The investigations are conducted in the boundary layer on a cone with an apex half-angle of 7° and varied bluntness radius of the nose tip [R = 0.03 (sharp nose), 0.75, and 1.5 mm] for different values of the local temperature factor. The nose tip is heated by an ohmic heater. Cooling is performed by supplying liquid nitrogen into the internal cavity of the model nose. A comparative analysis of pressure pulsation spectra on the cone surface is performed. It is demonstrated that heating/cooling in the case of a sharp cone leads to flow destabilization/stabilization. The opposite effect is observed for blunted cones: heating/cooling stabilizes/destabilizes the second-mode disturbances. This effect is enhanced by increasing the nose tip bluntness. All the observed effects vanish with distance downstream from the nose tip.

  2. High energy photoelectron spectroscopy in basic and applied science: Bulk and interface electronic structure

    Energy Technology Data Exchange (ETDEWEB)

    Knut, Ronny; Lindblad, Rebecka [Department of Physics and Astronomy, Uppsala University, SE-751 21 Uppsala (Sweden); Gorgoi, Mihaela [Helmholtz Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Rensmo, Håkan [Department of Physics and Astronomy, Uppsala University, SE-751 21 Uppsala (Sweden); Karis, Olof, E-mail: olof.karis@physics.uu.se [Department of Physics and Astronomy, Uppsala University, SE-751 21 Uppsala (Sweden)

    2013-10-15

    Highlights: •We demonstrate how hard X-ray photoelectron spectroscopy can be used to investigate interface properties of multilayers. •By combining HAXPES and statistical methods we are able to provide quantitative analysis of the interface diffusion process. •We show how photoionization cross sections can be used to map partial density of states contributions to valence states. •We use HAXPES to provide insight into the valence electronic structure of e.g. multiferroics and dye-sensitized solar cells. -- Abstract: With the access of new high-performance electron spectrometers capable of analyzing electron energies up to the order of 10 keV, the interest for photoelectron spectroscopy has grown and many new applications of the technique in areas where electron spectroscopies were considered to have limited use have been demonstrated over the last few decades. The technique, often denoted hard X-ray photoelectron spectroscopy (HX-PES or HAXPES), to distinguish the experiment from X-ray photoelectron spectroscopy performed at lower energies, has resulted in an increasing interest in photoelectron spectroscopy in many areas. The much increased mean free path at higher kinetic energies, in combination with the elemental selectivity of the core level spectroscopies in general has led to this fact. It is thus now possible to investigate the electronic structure of materials with a substantially enhanced bulk sensitivity. In this review we provide examples from our own research using HAXPES which to date has been performed mainly at the HIKE facility at the KMC-1 beamline at HZB, Berlin. The review exemplifies the new opportunities using HAXPES to address both bulk and interface electronic properties in systems relevant for applications in magnetic storage, energy related research, but also in purely curiosity driven problems.

  3. High energy photoelectron spectroscopy in basic and applied science: Bulk and interface electronic structure

    International Nuclear Information System (INIS)

    Knut, Ronny; Lindblad, Rebecka; Gorgoi, Mihaela; Rensmo, Håkan; Karis, Olof

    2013-01-01

    Highlights: •We demonstrate how hard X-ray photoelectron spectroscopy can be used to investigate interface properties of multilayers. •By combining HAXPES and statistical methods we are able to provide quantitative analysis of the interface diffusion process. •We show how photoionization cross sections can be used to map partial density of states contributions to valence states. •We use HAXPES to provide insight into the valence electronic structure of e.g. multiferroics and dye-sensitized solar cells. -- Abstract: With the access of new high-performance electron spectrometers capable of analyzing electron energies up to the order of 10 keV, the interest for photoelectron spectroscopy has grown and many new applications of the technique in areas where electron spectroscopies were considered to have limited use have been demonstrated over the last few decades. The technique, often denoted hard X-ray photoelectron spectroscopy (HX-PES or HAXPES), to distinguish the experiment from X-ray photoelectron spectroscopy performed at lower energies, has resulted in an increasing interest in photoelectron spectroscopy in many areas. The much increased mean free path at higher kinetic energies, in combination with the elemental selectivity of the core level spectroscopies in general has led to this fact. It is thus now possible to investigate the electronic structure of materials with a substantially enhanced bulk sensitivity. In this review we provide examples from our own research using HAXPES which to date has been performed mainly at the HIKE facility at the KMC-1 beamline at HZB, Berlin. The review exemplifies the new opportunities using HAXPES to address both bulk and interface electronic properties in systems relevant for applications in magnetic storage, energy related research, but also in purely curiosity driven problems

  4. A note on extracting electronic stopping from energy spectra of backscattered slow ions applying Bragg's rule

    Science.gov (United States)

    Bruckner, B.; Roth, D.; Goebl, D.; Bauer, P.; Primetzhofer, D.

    2018-05-01

    Electronic stopping measurements in chemically reactive targets, e.g., transition and rare earth metals are challenging. These metals often contain low Z impurities, which contribute to electronic stopping. In this article, we present two ways how one can correct for the presence of impurities in the evaluation of proton and He stopping in Ni for primary energies between 1 and 100 keV, either considering or ignoring the contribution of the low Z impurities to multiple scattering. We find, that for protons either method leads to concordant results, but for heavier projectiles, e.g. He ions, the influence on multiple scattering must not be neglected.

  5. Comparison of multivariate preprocessing techniques as applied to electronic tongue based pattern classification for black tea

    International Nuclear Information System (INIS)

    Palit, Mousumi; Tudu, Bipan; Bhattacharyya, Nabarun; Dutta, Ankur; Dutta, Pallab Kumar; Jana, Arun; Bandyopadhyay, Rajib; Chatterjee, Anutosh

    2010-01-01

    In an electronic tongue, preprocessing on raw data precedes pattern analysis and choice of the appropriate preprocessing technique is crucial for the performance of the pattern classifier. While attempting to classify different grades of black tea using a voltammetric electronic tongue, different preprocessing techniques have been explored and a comparison of their performances is presented in this paper. The preprocessing techniques are compared first by a quantitative measurement of separability followed by principle component analysis; and then two different supervised pattern recognition models based on neural networks are used to evaluate the performance of the preprocessing techniques.

  6. Pediatric Obesity and Ear, Nose, and Throat Disorders

    Science.gov (United States)

    ... Marketplace Find an ENT Doctor Near You Pediatric Obesity and Ear, Nose, and Throat Disorders Pediatric Obesity ... self-esteem, and isolation from their peers. Pediatric obesity and otolaryngic problems Otolaryngologists, or ear, nose, and ...

  7. Pediatric Obesity and Ear, Nose, and Throat Disorders

    Science.gov (United States)

    ... ENTCareers Marketplace Find an ENT Doctor Near You Pediatric Obesity and Ear, Nose, and Throat Disorders Pediatric ... of self-esteem, and isolation from their peers. Pediatric obesity and otolaryngic problems Otolaryngologists, or ear, nose, ...

  8. Experimental Route to Scanning Probe Hot Electron Nanoscopy (HENs) Applied to 2D Material

    KAUST Repository

    Giugni, Andrea; Torre, Bruno; Allione, Marco; Das, Gobind; Wang, Zhenwei; He, Xin; Alshareef, Husam N.; Di Fabrizio, Enzo M.

    2017-01-01

    for applications in electronics: 2D MoS2 single crystal and a p-type SnO layer. Results are supported by complementary scanning Kelvin probe microscopy, traditional conductive AFM, and Raman measurements. New features highlighted by HEN technique reveal details

  9. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  10. Applying Diffusion Theory to Electronic Publishing: A Conceptual Framework for Examining Issues and Outcomes.

    Science.gov (United States)

    Hahn, Karla L.; Schoch, Natalie A.

    1997-01-01

    Electronic publishing can best be understood as a cluster of related innovations which can be incorporated in different combinations. The innovation cluster is defined, and a framework is provided to characterize several recent publishing ventures demonstrating how the framework facilitates comparison and evaluation of individual implementations…

  11. Power Block Geometry Applied to the Building of Power Electronics Converters

    Science.gov (United States)

    dos Santos, E. C., Jr.; da Silva, E. R. C.

    2013-01-01

    This paper proposes a new methodology, Power Block Geometry (PBG), for the presentation of power electronics topologies that process ac voltage. PBG's strategy uses formal methods based on a geometrical representation with particular rules and defines a universe with axioms and conjectures to establish a formation law. It allows power…

  12. 14 CFR 67.205 - Ear, nose, throat, and equilibrium.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Ear, nose, throat, and equilibrium. 67.205..., nose, throat, and equilibrium. Ear, nose, throat, and equilibrium standards for a second-class airman..., vertigo or a disturbance of equilibrium. ...

  13. 14 CFR 67.105 - Ear, nose, throat, and equilibrium.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Ear, nose, throat, and equilibrium. 67.105..., nose, throat, and equilibrium. Ear, nose, throat, and equilibrium standards for a first-class airman... may reasonably be expected to be manifested by, vertigo or a disturbance of equilibrium. ...

  14. 14 CFR 67.305 - Ear, nose, throat, and equilibrium.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Ear, nose, throat, and equilibrium. 67.305..., nose, throat, and equilibrium. Ear, nose, throat, and equilibrium standards for a third-class airman... by, or that may reasonably be expected to be manifested by, vertigo or a disturbance of equilibrium. ...

  15. The Gendered Nose and its Lack: "Medieval" Nose-Cutting and its Modern Manifestations.

    Science.gov (United States)

    Skinner, Patricia

    2014-01-01

    Time magazine's cover photograph in August 2010 of a noseless Afghan woman beside the emotive strap line, "What happens if we leave Afghanistan," fuelled debate about the "medieval" practices of the Taliban, whose local commander had instructed her husband to take her nose and ears. Press reports attributed the violence to the Pashtun tradition that a dishonored husband "lost his nose." This equation of nose-cutting with tradition begs questions not only about the Orientalist lens of the western press when viewing Afghanistan, but also about the assumption that the word "medieval" can function as a label for such practices. A study of medieval nose-cutting suggests that its identification as an "eastern" practice should be challenged. Rather clearer is its connection with patriarchal values of authority and honor: the victims of such punishment have not always been women, but this is nevertheless a gendered punishment of the powerless by the powerful.

  16. Headaches from ear, nose and throat diseases

    International Nuclear Information System (INIS)

    Reck, R.

    1984-01-01

    Headaches are a frequent symptom in ENT-patients. The complex sensory innervation of the ear, nose and paranasal sinuses is demonstrated. Heterotopic or referred pain must be differentiated from homotopic pain that is experienced at the point of injury. The nervous pathways of heterotopic otalgia are shown. The quality of pain of the most common rhinological and otological diseases is reported. (orig.) [de

  17. Why Rudolph's nose is red: Observational study

    NARCIS (Netherlands)

    C. Ince (Can); A.-M. van Kuijen (Anne-Marijevan); D.M.J. Milstein (Dan); K. Yuruk (Koray); L.P. Folkow (Lars P); W.J. Fokkens (Wytske); A.S. Blix (Arnoldus S)

    2012-01-01

    textabstractObjective: To characterise the functional morphology of the nasal microcirculation in humans in comparison with reindeer as a means of testing the hypothesis that the luminous red nose of Rudolph, one of the most well known reindeer pulling Santa Claus's sleigh, is due to the presence of

  18. Identification of a potential fibromyalgia diagnosis using random forest modeling applied to electronic medical records

    OpenAIRE

    Masters, Elizabeth T.; Emir,Birol; Mardekian,Jack; Clair,Andrew; Kuhn,Max; Silverman,Stuart

    2015-01-01

    Birol Emir,1 Elizabeth T Masters,1 Jack Mardekian,1 Andrew Clair,1 Max Kuhn,2 Stuart L Silverman,3 1Pfizer Inc., New York, NY, 2Pfizer Inc., Groton, CT, 3Cedars-Sinai Medical Center, Los Angeles, CA, USA Background: Diagnosis of fibromyalgia (FM), a chronic musculoskeletal condition characterized by widespread pain and a constellation of symptoms, remains challenging and is often delayed. Methods: Random forest modeling of electronic medical records was used to identify variables that may fa...

  19. The interperiosteo-dural concept applied to the perisellar compartment: a microanatomical and electron microscopic study.

    Science.gov (United States)

    François, Patrick; Travers, Nadine; Lescanne, Emmanuel; Arbeille, Brigitte; Jan, Michel; Velut, Stéphane

    2010-11-01

    The dura mater has 2 dural layers: the endosteal layer (outer layer), which is firmly attached to the bone, and the meningeal layer (inner layer), which directly covers the brain. These 2 dural layers join together in the middle temporal fossa or the convexity and separate into the orbital, lateral sellar compartment (LSC), or spinal epidural space to form the extradural neural axis compartment (EDNAC). The aim of this work was to anatomically verify the concept of the EDNAC by using electron microscopy. The authors studied the cadaveric heads obtained from 13 adults. Ten of the specimens (or 20 perisellar areas) were injected with colored latex and fixed in formalin. They carefully removed each brain to allow a superior approach to the perisellar area. The 3 other specimens were studied by microscopic and ultrastructural methods to describe the EDNAC in the perisellar area. Special attention was paid to the dural layers surrounding the perisellar area. The authors studied the anatomy of the meningeal architecture of the LSC, the petroclival venous confluence, the orbit, and the trigeminal cave. After dissection, the authors took photographs of the dural layers with the aid of optical magnification. The 3 remaining heads, obtained from fresh cadavers, were prepared for electron microscopic study. The EDNAC is limited by the endosteal layer and the meningeal layer and contains fat and/or venous blood. The endosteal layer and meningeal layer were not identical on electron microscopy; this finding can be readily related to the histology of the meninges. In this study, the authors demonstrated the existence of the EDNAC concept in the perisellar area by using dissected cadaveric heads and verified the reality of the concept of the meningeal layer with electron microscopy. These findings clearly demonstrated the existence of the EDNAC, a notion that has generally been accepted but never demonstrated microscopically.

  20. Development of a novel thermionic RF electron gun applied on a compact THz-FEL facility

    Science.gov (United States)

    Hu, T. N.; Pei, Y. J.; Qin, B.; Liu, K. F.; Feng, G. Y.

    2018-04-01

    The current requirements from civil and commercial applications lead to the development of compact free-electron laser (FEL)-based terahertz (THz) radiation sources. A picosecond electron gun plays an important role in an FEL-THz facility and attracts significant attention, as machine performance is very sensitive to initial conditions. A novel thermionic gun with an external cathode (EC) and two independently tunable cavities (ITCs) has been found to be a promising alternative to conventional electron sources due to its remarkable characteristics, and correspondingly an FEL injector can achieve a balance between a compact layout and high brightness benefitting from the velocity bunching properties and RF focusing effects in the EC-ITC gun. Nevertheless, the EC-ITC gun has not been extensively examined as part of the FEL injector in the past years. In this regard, to fill this gap, a development focusing on the experimental setup of an FEL injector based on an EC-ITC gun is described in detail. Before assembly, dynamic beam simulations were performed to investigate the optimal mounting position for the Linac associated with the focusing coils, and a suitable radio-frequency (RF) system was established based on a power coupling design and allocation. The testing bench proved to be fully functional through basic experiments using typical diagnostic approaches for estimating primary parameters. Associated with dynamic beam calculations, a performance evaluation for an EC-ITC gun was established while providing indirect testing results for an FEL injector.

  1. The measurement of the total electron content applied to the observation of medium scale gravity wave

    International Nuclear Information System (INIS)

    Bertel, L.; Bertin, F.; Testud, J.

    1976-01-01

    The interpretation of the measurements of the integrated electron content in terms of gravity wave requires (1) a gravity wave model at thermospheric altitudes; (2) a gravity wave-ionization interaction model in the F-region of the ionosphere; and (3) a computing program for the resulting perturbation on the integrated electron content between the satellite and the earth station used. The gravity wave model considered in this paper takes into account the dissipative effects (viscosity, thermal conduction) which become very importanr above 250 km altitude and the effect of the base wind which is capable of affecting deeply the propagation of the waves of medium scale. Starting with this model, the domains of frequencies and the wavelength of atmospheric waves which may exist in the upper atmosphere are considered. The interaction of such waves and the ionization is examined. The theoretical results give information particularly on the selectivity of the ionospheric response to the wave passage. The deduced selectivity of the models appears to be smaller than that given by other authors who used simplified gravity wave models. The method for computing the perturbation of the of the integrated electron content introduced by the wave passage is given for a geostationary satellite. Computational results are presented for application to the case of medium scale gravity waves. (author)

  2. Electron crystallography applied to the structure determination of Nb(Cu,Al,X) Laves phases.

    Science.gov (United States)

    Gigla, M; Lelatko, J; Krzelowski, M; Morawiec, H

    2006-09-01

    The presence of primary precipitates of the Laves phases considerably improves the mechanical properties and the resistance to thermal degradation of the high-temperature shape memory Cu-Al-Nb alloys. The structure analysis of the Laves phases was carried out on particles contained in the ternary and quaternary alloys as well on synthesized compounds related to the composition of the Nb(Cu,Al,X)(2) phase, where X = Ni, Co, Cr, Ti and Zr. The precise structure determination of the Laves phases was carried out by the electron crystallography method using the CRISP software.

  3. Teaching strategies applied to teaching computer networks in Engineering in Telecommunications and Electronics

    Directory of Open Access Journals (Sweden)

    Elio Manuel Castañeda-González

    2016-07-01

    Full Text Available Because of the large impact that today computer networks, their study in related fields such as Telecommunications Engineering and Electronics is presented to the student with great appeal. However, by digging in content, lacking a strong practical component, you can make this interest decreases considerably. This paper proposes the use of teaching strategies and analogies, media and interactive applications that enhance the teaching of discipline networks and encourage their study. It is part of an analysis of how the teaching of the discipline process is performed and then a description of each of these strategies is done with their respective contribution to student learning.

  4. Difficulties in applying pure Kohn-Sham density functional theory electronic structure methods to protein molecules

    Science.gov (United States)

    Rudberg, Elias

    2012-02-01

    Self-consistency-based Kohn-Sham density functional theory (KS-DFT) electronic structure calculations with Gaussian basis sets are reported for a set of 17 protein-like molecules with geometries obtained from the Protein Data Bank. It is found that in many cases such calculations do not converge due to vanishing HOMO-LUMO gaps. A sequence of polyproline I helix molecules is also studied and it is found that self-consistency calculations using pure functionals fail to converge for helices longer than six proline units. Since the computed gap is strongly correlated to the fraction of Hartree-Fock exchange, test calculations using both pure and hybrid density functionals are reported. The tested methods include the pure functionals BLYP, PBE and LDA, as well as Hartree-Fock and the hybrid functionals BHandHLYP, B3LYP and PBE0. The effect of including solvent molecules in the calculations is studied, and it is found that the inclusion of explicit solvent molecules around the protein fragment in many cases gives a larger gap, but that convergence problems due to vanishing gaps still occur in calculations with pure functionals. In order to achieve converged results, some modeling of the charge distribution of solvent water molecules outside the electronic structure calculation is needed. Representing solvent water molecules by a simple point charge distribution is found to give non-vanishing HOMO-LUMO gaps for the tested protein-like systems also for pure functionals.

  5. An electronically tunable ultrafast laser source applied to fluorescence imaging and fluorescence lifetime imaging microscopy

    International Nuclear Information System (INIS)

    Dunsby, C; Lanigan, P M P; McGinty, J; Elson, D S; Requejo-Isidro, J; Munro, I; Galletly, N; McCann, F; Treanor, B; Oenfelt, B; Davis, D M; Neil, M A A; French, P M W

    2004-01-01

    Fluorescence imaging is used widely in microscopy and macroscopic imaging applications for fields ranging from biomedicine to materials science. A critical component for any fluorescence imaging system is the excitation source. Traditionally, wide-field systems use filtered thermal or arc-generated white light sources, while point scanning confocal microscope systems require spatially coherent (point-like) laser sources. Unfortunately, the limited range of visible wavelengths available from conventional laser sources constrains the design and usefulness of fluorescent probes in confocal microscopy. A 'hands-off' laser-like source, electronically tunable across the visible spectrum, would be invaluable for fluorescence imaging and provide new opportunities, e.g. automated excitation fingerprinting and in situ measurement of excitation cross-sections. Yet more information can be obtained using fluorescence lifetime imaging (FLIM), which requires that the light source be pulsed or rapidly modulated. We show how a white light continuum, generated by injecting femtosecond optical radiation into a micro-structured optical fibre, coupled with a simple prism-based tunable filter arrangement, can fulfil all these roles as a continuously electronically tunable (435-1150 nm) visible ultrafast light source in confocal, wide-field and FLIM systems

  6. Electron backscatter diffraction applied to lithium sheets prepared by broad ion beam milling.

    Science.gov (United States)

    Brodusch, Nicolas; Zaghib, Karim; Gauvin, Raynald

    2015-01-01

    Due to its very low hardness and atomic number, pure lithium cannot be prepared by conventional methods prior to scanning electron microscopy analysis. Here, we report on the characterization of pure lithium metallic sheets used as base electrodes in the lithium-ion battery technology using electron backscatter diffraction (EBSD) and X-ray microanalysis using energy dispersive spectroscopy (EDS) after the sheet surface was polished by broad argon ion milling (IM). No grinding and polishing were necessary to achieve the sufficiently damage free necessary for surface analysis. Based on EDS results the impurities could be characterized and EBSD revealed the microsctructure and microtexture of this material with accuracy. The beam damage and oxidation/hydration resulting from the intensive use of IM and the transfer of the sample into the microscope chamber was estimated to be effect on the surface temperature. However, a cryo-stage should be used if available during milling to guaranty a heating artefact free surface after the milling process. © 2014 Wiley Periodicals, Inc.

  7. Difficulties in applying pure Kohn-Sham density functional theory electronic structure methods to protein molecules

    International Nuclear Information System (INIS)

    Rudberg, Elias

    2012-01-01

    Self-consistency-based Kohn-Sham density functional theory (KS-DFT) electronic structure calculations with Gaussian basis sets are reported for a set of 17 protein-like molecules with geometries obtained from the Protein Data Bank. It is found that in many cases such calculations do not converge due to vanishing HOMO-LUMO gaps. A sequence of polyproline I helix molecules is also studied and it is found that self-consistency calculations using pure functionals fail to converge for helices longer than six proline units. Since the computed gap is strongly correlated to the fraction of Hartree-Fock exchange, test calculations using both pure and hybrid density functionals are reported. The tested methods include the pure functionals BLYP, PBE and LDA, as well as Hartree-Fock and the hybrid functionals BHandHLYP, B3LYP and PBE0. The effect of including solvent molecules in the calculations is studied, and it is found that the inclusion of explicit solvent molecules around the protein fragment in many cases gives a larger gap, but that convergence problems due to vanishing gaps still occur in calculations with pure functionals. In order to achieve converged results, some modeling of the charge distribution of solvent water molecules outside the electronic structure calculation is needed. Representing solvent water molecules by a simple point charge distribution is found to give non-vanishing HOMO-LUMO gaps for the tested protein-like systems also for pure functionals. (fast track communication)

  8. When in doubt follow your nose – a wayfinding strategy

    Directory of Open Access Journals (Sweden)

    Tobias eMeilinger

    2014-11-01

    Full Text Available Route selection is governed by various strategies which often allow minimizing the required memory capacity. Previous research showed that navigators primarily remember information at route decision points and at route turns, rather than at intersections which required straight walking. However, when actually navigating the route or indicating directional decisions, navigators make fewer errors when they are required to walk straight. This tradeoff between location memory and route decisions accuracy was interpreted as a when in doubt follow your nose strategy which allows navigators to only memorize turns and walk straight by default, thus considerably reducing the number of intersections to memorize. These findings were based on newly learned routes. In the present study we show that such an asymmetry in route memory also prevails for planning routes within highly familiar environments. Participants planned route sequences between locations in their city of residency by pressing arrow keys on a keyboard. They tended to ignore straight walking intersections, but they ignored turns much less so. However, for reported intersections participants were quicker at indicating straight walking than turning. Together with results described in the literature, these findings suggest that a when in doubt follow your nose strategy is applied also within highly familiar spaces and might originate from limited working memory capacity during planning a route.

  9. Investigation of Mn Implanted LiNbO3 applying electron paramagnetic resonance technique

    International Nuclear Information System (INIS)

    Darwish, A.; Ila, D.; Poker, D.B.; Hensley, D.K.

    1997-10-01

    The effect of ion implantation on the LiNbO 3 crystal is studied using electron paramagnetic resonance spectroscopy (EPR). EPR measurements on these crystals were performed as a function of ion species Mn and Fe and fluence at room temperature. Also the effect of the laser illumination on the EPR signal was determined by illuminating the crystal in situ and measuring the decay and growth of the EPR signal. LiNbO 3 :Mn 2+ at a depth of approximately 200 nm was formed by implantation of 2.5 x 10 14 Mncm 2 and 1 x 10 17 Mn/cm 2 at 2 MeV. The implanted samples were compared with bulk doped crystals. It was found that the decay and growth of Mn EPR for the implanted crystal is very small compared with the bulk doped LiNbO 3 :Mn crystal. This was found to be primarily due to the spin concentration on the crystals. On the other, hand the decay time of the high fluence is about 40% slower than the decay of the low fluence implanted crystal

  10. The vortex-like self-consistent electron fluid model by the applied-B ion diode: equilibrium and instability

    Energy Technology Data Exchange (ETDEWEB)

    Gordeev, A V [Kurchatov Institute, Moscow (Russian Federation). Nuclear Fusion Institute

    1997-12-31

    The electron inertia effects in the one-dimensional model of the applied-B ion diode for the relativistic diode potential eU/m{sub e}c{sup 2} {>=} 1 were investigated, where the magnetic Debye length r{sub B} is of the order of the collisionless electron skin depth c/{omega}{sub pe}. For this, an analytical relation between the magnetic field and the electric potential was developed, owing to which the second order eigenvalue problem can be reduced to a system of algebraic equations. Instabilities inside the vacuum gap and in the near-anode emitting plasma are considered. In the near-anode Hall plasma, the instability with two ion species was obtained; this can can contribute to the ion angle divergence. (author). 10 refs.

  11. The vortex-like self-consistent electron fluid model by the applied-B ion diode: equilibrium and instability

    International Nuclear Information System (INIS)

    Gordeev, A.V.

    1996-01-01

    The electron inertia effects in the one-dimensional model of the applied-B ion diode for the relativistic diode potential eU/m e c 2 ≥ 1 were investigated, where the magnetic Debye length r B is of the order of the collisionless electron skin depth c/ω pe . For this, an analytical relation between the magnetic field and the electric potential was developed, owing to which the second order eigenvalue problem can be reduced to a system of algebraic equations. Instabilities inside the vacuum gap and in the near-anode emitting plasma are considered. In the near-anode Hall plasma, the instability with two ion species was obtained; this can can contribute to the ion angle divergence. (author). 10 refs

  12. Treatment verification with megavoltage electronic portal imaging applied to the tomotherapy concept

    International Nuclear Information System (INIS)

    Hesse, B.-M.; Spies, L.; Groh, B.; Doll, J.; Haering, P.; Hoever, K. H.

    1997-01-01

    Purpose: A new treatment strategy called Tomotherapy, introduced by T. R. Mackie et al. in 1993, was designed to perform a dynamic conformal treatment technique in precision radiotherapy. This technique delivers sliced intensity-modulated radiation fields to achieve best tumor control while sparing neighbouring sensitive normal tissue and organs at risk. The beam continuously revolves around the patient similarly to a spiral-CT while the patient is moved through the bore of the gantry. As a first step towards the realization of such a concept with a linear accelerator (Siemens Mevatron Experimental) used in clinical routine, we focused on treatment setup and dose verification. In tomotherapy, an actual CT data set is needed for patient positioning and for the verification of the absorbed dose, also, the dose transmitted through the patient must be known. This makes possible both routine tomographic treatment setup verification and tomographic dose reconstruction of the actual delivered dose. Materials and Methods: All measurements were performed with a megavoltage electronic portal imaging device of Wellhoefer TM (BIS-710). The BIS-710 detector is based on a scintillation foil and contains a camera for 10-bit digital data output. The dimension of the detector plane is 512 x 512 pixels with a pixel size of 0.6 mm in each direction. The BIS-710 was developed especially for quantitative dose measuring, whereas most of the existing Portal Imaging Systems are used for image display only. To examine the properties of the BIS-710 concerning tomographical reconstruction with a therapeutic 6 MV X-ray beam, a tissue-equivalent Alderson head phantom was rotated stepwise across a stationary beam between the collimator and the detector plane. The influence of scattering can be estimated by comparing measurements which were taken with a homogeneous phantom which is invariant under rotation with a calculated exit dose distribution using a simple exponential law for the

  13. Quality assurance as an integrated part of the electronic medical record - a prototype applied for colonoscopy.

    Science.gov (United States)

    Hoff, Geir; Ottestad, Per Marcus; Skafløtten, Stein Roger; Bretthauer, Michael; Moritz, Volker

    2009-01-01

    Electronic medical records (EMRs) have not developed much beyond the days of typewritten journals when it comes to facilitating extraction of data for quality assurance (QA) and improvement of health-care performance. Based on 5 years' experience from the Norwegian Gastronet QA programme, we have developed a highly QA-profiled EMR for colonoscopy. We used a three-tier solution (client, server and database) written in the Java programming language using a number of open-source libraries. QA principles from the Norwegian paper-based Gastronet QA programme formed the basis for development of the ColoReg software. ColoReg is developed primarily for colonoscopy reporting in a screening trial, but may be used in routine clinical work. The QA module in ColoReg is well suited for intervention towards suboptimal performance in both settings. We have developed user-friendly software dominated by clickable boxes and curtain menus reducing free text to a minimum. The software gives warnings when illogical registrations are entered and reasons have to be given for divergence from software recommendations for work-up and surveillance. At any time, defined performance quality parameters are readily accessible in tabular form with the named, logged-in endoscopist being compared with all other anonymized endoscopists in the database. The ColoReg software is developed for use in an international, multicentre trial on colonoscopy screening. It is user-friendly and secures continuous QA of the endoscopist's performance. The principles used are applicable to development of EMRs in general.

  14. Electron beam irradiation process applied to primary and secondary recycled high density polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Jéssica R.; Moura, Eduardo de; Geraldo, Áurea B.C., E-mail: ageraldo@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    Plastic bags, packaging and furniture items are examples of plastic utilities always present in life. However, the end-of-life of plastics impacts the environment because of this ubiquity and also often their high degradation time. Recycling processes are important in this scenario because they offer many solutions to this problem. Basically, four ways are known for plastic recycling: primary recycling, which consists in re-extrusion of clean plastic scraps from a production plant; secondary recycling, that uses end-of-life products that generally are reduced in size by extrusion to obtain a more desirable shape for reprocessing (pellets and powder); tertiary recover which is related to thermo-chemical methods to produce fuels and petrochemical feedstock; and quaternary route, that is related to energy recovery and it is done in appropriate reactors. In this work, high density polyethylene (HDPE) was recovered to simulate empirically the primary and secondary recycling ways using materials which ranged from pristine to 20-fold re-extrused materials. The final 20-fold recycled thermoplastic was irradiated in an electron beam accelerator under a dose rate of 22.4 kGy/s and absorbed doses of 50 kGy and 100 kGy. The characterization of HDPE in distinct levels of recovering was performed by infrared spectroscopy (FTIR) and thermogravimetric degradation. In the HDPE recycling, degradation and crosslinking are consecutive processes; degradation is very noticeable in the 20-fold recycled product. Despite this, the 20-fold recycled product presents crosslinking after irradiation process and the post-irradiation product presents similarities in spectroscopic and thermal degradation characteristics of pristine, irradiated HDPE. These results are discussed. (author)

  15. Electron beam irradiation process applied to primary and secondary recycled high density polyethylene

    International Nuclear Information System (INIS)

    Cardoso, Jéssica R.; Moura, Eduardo de; Geraldo, Áurea B.C.

    2017-01-01

    Plastic bags, packaging and furniture items are examples of plastic utilities always present in life. However, the end-of-life of plastics impacts the environment because of this ubiquity and also often their high degradation time. Recycling processes are important in this scenario because they offer many solutions to this problem. Basically, four ways are known for plastic recycling: primary recycling, which consists in re-extrusion of clean plastic scraps from a production plant; secondary recycling, that uses end-of-life products that generally are reduced in size by extrusion to obtain a more desirable shape for reprocessing (pellets and powder); tertiary recover which is related to thermo-chemical methods to produce fuels and petrochemical feedstock; and quaternary route, that is related to energy recovery and it is done in appropriate reactors. In this work, high density polyethylene (HDPE) was recovered to simulate empirically the primary and secondary recycling ways using materials which ranged from pristine to 20-fold re-extrused materials. The final 20-fold recycled thermoplastic was irradiated in an electron beam accelerator under a dose rate of 22.4 kGy/s and absorbed doses of 50 kGy and 100 kGy. The characterization of HDPE in distinct levels of recovering was performed by infrared spectroscopy (FTIR) and thermogravimetric degradation. In the HDPE recycling, degradation and crosslinking are consecutive processes; degradation is very noticeable in the 20-fold recycled product. Despite this, the 20-fold recycled product presents crosslinking after irradiation process and the post-irradiation product presents similarities in spectroscopic and thermal degradation characteristics of pristine, irradiated HDPE. These results are discussed. (author)

  16. Applying representational state transfer (REST) architecture to archetype-based electronic health record systems

    Science.gov (United States)

    2013-01-01

    Background The openEHR project and the closely related ISO 13606 standard have defined structures supporting the content of Electronic Health Records (EHRs). However, there is not yet any finalized openEHR specification of a service interface to aid application developers in creating, accessing, and storing the EHR content. The aim of this paper is to explore how the Representational State Transfer (REST) architectural style can be used as a basis for a platform-independent, HTTP-based openEHR service interface. Associated benefits and tradeoffs of such a design are also explored. Results The main contribution is the formalization of the openEHR storage, retrieval, and version-handling semantics and related services into an implementable HTTP-based service interface. The modular design makes it possible to prototype, test, replicate, distribute, cache, and load-balance the system using ordinary web technology. Other contributions are approaches to query and retrieval of the EHR content that takes caching, logging, and distribution into account. Triggering on EHR change events is also explored. A final contribution is an open source openEHR implementation using the above-mentioned approaches to create LiU EEE, an educational EHR environment intended to help newcomers and developers experiment with and learn about the archetype-based EHR approach and enable rapid prototyping. Conclusions Using REST addressed many architectural concerns in a successful way, but an additional messaging component was needed to address some architectural aspects. Many of our approaches are likely of value to other archetype-based EHR implementations and may contribute to associated service model specifications. PMID:23656624

  17. Nose muscular dynamics: the tip trigonum.

    Science.gov (United States)

    Figallo, E E; Acosta, J A

    2001-10-01

    In 1995, the senior author (E.E.F.) published an article in which he described the musculus digastricus septi nasi labialis. In the article presented here, work carried out by anatomists and other researchers who, over the last two centuries, studied nose muscular dynamics is described. The present study is based on Gray's Anatomy, which, in 1858, first described the nasal tip muscles, along with the other nasal muscles. Later works not only used different terminology for these muscles but also ignored some, creating tremendous confusion. The study presented here provides an update of the exact terms, location, insertions, and muscle functions of the muscles of the nose. Each nose muscle is described with regard to the two portions able to produce separate contractions. In this study, the term "dual function" is used and characterizes the nasal mimetic muscles that do not have well-defined fascia. Therefore, there is doubt about the existence of a real nasal superficial muscle aponeurotic system. The musculus myrtiformis seems to have a dual function, inserting in the canine fosse and in the periosteum of the central incisors, forming two portions-one to the septum and the other to the nostril-each of which has specific functions. This study has been based on research in physiognomy, the science of expression. With regard to the basis for nose expressions, common anatomical research is excluded because it provides a different view of the dynamics studied to date. The term trigonum musculare apicis nasi defines the interaction of the musculi compressor narium minor and dilator naris anterior, connecting with the columellar bundle of the musculus digastricus and levering the nasal spine. This muscular trigone creates circular concentric and eccentric movements of the nasal tip.

  18. Complication of nose and paranasal sinus disease

    International Nuclear Information System (INIS)

    Kazmi, H.S.; Ali, S.; Ali, Z.

    2012-01-01

    Diseases of nose and paranasal sinuses can complicate to involve the orbit and other surrounding structures because of their close proximity. These diseases are usually infective or can be neoplastic in origin. Method: All the patients presenting in ENT or Eye Departments of Ayub Teaching Hospital during the one year study period who had complicated nose or paranasal sinus disease were included in the study. A detailed history and examination followed by CT scanning and laboratory investigations to assess the type and extent of the disease, was carried out. Results: Infections were the most common cause of complicated sinus disease 11 (75%). The rest of the 4 (25%) cases were tumours. 12 (80%) of the cases presented with proptosis. In 1 of these 12 cases, there was complete blindness. In 2 (13%) of the cases there was only orbital cellulitis. Two of these patients had facial swelling and 2 had nasal obstruction and presented as snoring. Two patients presented with history of weight loss and these patients had malignant tumour of the paranasal sinuses. One patient presented with early signs of meningitis. In 1 case sub periosteal scalp abscess (Pott's puffy tumour) was the only complication noted. Conclusion: Nose and paranasal sinus diseases can complicate to involve mostly the orbit, but sometimes brain, meninges and skull bones can also get involved. (author)

  19. Rhinoplasty for the multiply revised nose.

    Science.gov (United States)

    Foda, Hossam M T

    2005-01-01

    To evaluate the problems encountered on revising a multiply operated nose and the methods used in correcting such problems. The study included 50 cases presenting for revision rhinoplasty after having had 2 or more previous rhinoplasties. An external rhinoplasty approach was used in all cases. Simultaneous septal surgery was done whenever indicated. All cases were followed for a mean period of 32 months (range, 1.5-8 years). Evaluation of the surgical result depended on clinical examination, comparison of pre- and postoperative photographs, and degree of patients' satisfaction with their aesthetic and functional outcome. Functionally, 68% suffered nasal obstruction that was mainly caused by septal deviations and nasal valve problems. Aesthetically, the most common deformities of the upper two thirds of the nose included pollybeak (64%), dorsal irregularities (54%), dorsal saddle (44%), and open roof deformity (42%), whereas the deformities of lower third included depressed tip (68%), tip contour irregularities (60%), and overrotated tip (42%). Nasal grafting was necessary in all cases; usually more than 1 type of graft was used in each case. Postoperatively, 79% of the patients, with preoperative nasal obstruction, reported improved breathing; 84% were satisfied with their aesthetic result; and only 8 cases (16%) requested further revision to correct minor deformities. Revision of a multiply operated nose is a complex and technically demanding task, yet, in a good percentage of cases, aesthetic as well as functional improvement are still possible.

  20. A review on remote monitoring technology applied to implantable electronic cardiovascular devices.

    Science.gov (United States)

    Costa, Paulo Dias; Rodrigues, Pedro Pereira; Reis, António Hipólito; Costa-Pereira, Altamiro

    2010-12-01

    Implantable electronic cardiovascular devices (IECD) include a broad spectrum of devices that have the ability to maintain rhythm, provide cardiac resynchronization therapy, and/or prevent sudden cardiac death. The incidence of bradyarrhythmias and other cardiac problems led to a broader use of IECD, which turned traditional follow-up into an extremely heavy burden for healthcare systems to support. Our aim was to assess the impact of remote monitoring on the follow-up of patients with IECD. We performed a review through PubMed using a specific query. The paper selection process included a three-step approach in which title, abstract, and cross-references were analyzed. Studies were then selected using previously defined inclusion criteria and analyzed according to the country of origin of the study, year, and journal of publication; type of study; and main issues covered. Twenty articles were included in this review. Eighty percent of the selected papers addressed clinical issues, from which 94% referred clinical events identification, clinical stability, time savings, or physician satisfaction as advantages, whereas 38% referred disadvantages that included both legal and technical issues. Forty-five percent of the papers referred patient issues, from which 89% presented advantages, focusing on patient acceptance/satisfaction, and patient time-savings. The main downsides were technical issues but patient privacy was also addressed. All the papers dealing with economic issues (20%) referred both advantages and disadvantages equally. Remote monitoring is presently a safe technology, widely accepted by patients and physicians, for its convenience, reassurance, and diagnostic potential. This review summarizes the principles of remote IECD monitoring presenting the current state-of-the-art. Patient safety and device interaction, applicability of current technology, and limitations of remote IECD monitoring are also addressed. The use of remote monitor should consider

  1. Multisubband electron mobility in a parabolic quantum well structure under the influence of an applied electric field

    International Nuclear Information System (INIS)

    Sahoo, N.; Sahu, T.

    2014-01-01

    We study the multisubband electron mobility in a barrier delta doped Al x Ga 1−x As parabolic quantum well structure under the influence of an applied electric field perpendicular to the interface plane. We consider the alloy fraction x = 0.3 for barriers and vary x from 0.0 to 0.1 for the parabolic well. Electrons diffuse into the well and confine within the triangular like potentials near the interfaces due to Coulomb interaction with ionized donors. The parabolic structure potential, being opposite in nature, partly compensates the Coulomb potential. The external electric field further amends the potential structure leading to an asymmetric potential profile. Accordingly the energy levels, wave functions and occupation of subbands change. We calculate low temperature electron mobility as a function of the electric field and show that when two subbands are occupied, the mobility is mostly dominated by ionised impurity scattering mediated by intersubband effects. As the field increases transition from double subband to single subband occupancy occurs. A sudden enhancement in mobility is obtained due to curtailment of intersubband effects. Thereafter the mobility is governed by both impurity and alloy disorder scatterings. Our analysis of mobility as a function of the electric field for different structural parameters shows interesting results. (semiconductor physics)

  2. Prehrana in telesna aktivnost nosečnice

    OpenAIRE

    Ciglar, Ksenija

    2012-01-01

    V diplomskem delu smo predstavili nosečnost kot stanje fizioloških in psiholoških sprememb ter prehrano in telesno aktivnost nosečnice. Zdrava in uravnotežena prehrana je pomembna v vseh življenjskih obdobjih ženske, še posebej pa pred nosečnostjo, v nosečnosti in v času laktacije. Telesna ali športna dejavnost pa vpliva pozitivno na nosečničino zdravje in dobro počutje. Diplomsko delo je sestavljeno iz dveh delov. V prvem (teoretičnem) delu je predstavljena fiziologija nosečnosti, prehrana ...

  3. Acoustic rhinometry of the Indian and Anglo-Saxon nose.

    Science.gov (United States)

    Gurr, P; Diver, J; Morgan, N; MacGregor, F; Lund, V

    1996-09-01

    The internal and external geometry of the nose has previously been shown to differ between Anglo-Saxon, Chinese, and Negro noses. It is therefore important to define the normal geometric nasal parameters of a given race, so as to detect the abnormal nose. We present acoustic rhinometric data, with height-adjusted figures, examining the nasal minimum cross-sectional area (MCA), the distance to the nostril from the MCA, and the MCA between 0-6 cm. These data show no significant differences between Indian and Anglo-Saxon noses.

  4. The Gendered Nose and its Lack: “Medieval” Nose-Cutting and its Modern Manifestations

    Science.gov (United States)

    Skinner, Patricia

    2014-01-01

    Time magazine’s cover photograph in August 2010 of a noseless Afghan woman beside the emotive strap line, “What happens if we leave Afghanistan,” fuelled debate about the “medieval” practices of the Taliban, whose local commander had instructed her husband to take her nose and ears. Press reports attributed the violence to the Pashtun tradition that a dishonored husband “lost his nose.” This equation of nose-cutting with tradition begs questions not only about the Orientalist lens of the western press when viewing Afghanistan, but also about the assumption that the word “medieval” can function as a label for such practices. A study of medieval nose-cutting suggests that its identification as an “eastern” practice should be challenged. Rather clearer is its connection with patriarchal values of authority and honor: the victims of such punishment have not always been women, but this is nevertheless a gendered punishment of the powerless by the powerful. PMID:24790391

  5. Characterization of pigments applied on archaeological material from Chincha's Culture by x-rays fluorescence and transmission electronic microscopy

    International Nuclear Information System (INIS)

    Lopez M, Alcides; Olivera, Paula

    2007-01-01

    The elementary characterization of some pigments applied in the decoration of recipients used by our ancestors of the Chincha Culture by Energy dispersive X-ray fluorescence (EDXRF)method was allowed. Additionally, the morphological and crystalline characterization by Transmission Electronic Microscopy (TEM) method has been possible. The results have allowed identifying the presence of mercury sulphur (HgS) (cinnabar) in the red pigment on the 'mate'; the black and white pigments are constituted by materials of organic aspect; in the case the dark brown one they are constituted by organic matter and ferric oxide. This work also demonstrates that a portable EDXRF spectrometer is the most suitable for the study of pieces of our cultural patrimony, mainly of those that are difficult to transport from an archaeological place or museum to an analytic laboratory by reason of its dimensions and conservation conditions. (author)

  6. Electronic bound states in parity-preserving QED{sub 3} applied to high-T{sub c} cuprate superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Christiansen, H.R. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil). Coordenacao de Teoria de Campos e Particulas]. E-mail: hugo@cbpf.br; Cima, O.M. Del [Universidade Catolica de Petropolis, RJ (Brazil). Grupo de Fisica Teorica]. E-mail: delcima@gft.ucp.br; Ferreira Junior, M.M. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil). Coordenacao de Teoria de Campos e Particulas]|[Maranhao Univ., Sao Luis, MA (Brazil). Dept. de Fisica]. E-mail: manojr@cbpf.br; Helayel-Neto, J.A. [Universidade Catolica de Petropolis, RJ (Brazil). Grupo de Fisica Teorica]|[Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil). Coordenacao de Teoria de Campos e Particulas]. E-mail: helayel@gft.ucp.br

    2001-08-01

    We consider a parity-preserving QED{sub 3} model with spontaneous breaking of the gauge symmetry as a framework for the evaluation of the electron-electron interaction potential underlying high-T{sub e} superconductivity. The fact that resulting potential, - C{sub s} K{sub o} (Mr), is non-confining and weak (in the sense of Kato) strongly suggests the mechanism of pair-condensation. This potential, compatible with an s-wave order parameters, is then applied to the Schrodinger equation for the sake of numerical calculations, thereby enforcing the existence of bound states. The results worked out by means of our theoretical framework are checked by considering a number of phenomenological data extracted from different copper oxide superconductors. The agreement may motivate a deeper analysis of our model viewing an application to quasi-planar cuprate superconductors. The data analyzed here suggest an energy scale of 1-10 meV for the breaking of the U(1)-symmetry. (author)

  7. Development of the MOOSY4 eNose IoT for Sulphur-Based VOC Water Pollution Detection.

    Science.gov (United States)

    Climent, Enric; Pelegri-Sebastia, Jose; Sogorb, Tomas; Talens, J B; Chilo, Jose

    2017-08-20

    In this paper, we describe a new low-cost and portable electronic nose instrument, the Multisensory Odor Olfactory System MOOSY4. This prototype is based on only four metal oxide semiconductor (MOS) gas sensors suitable for IoT technology. The system architecture consists of four stages: data acquisition, data storage, data processing, and user interfacing. The designed eNose was tested with experiment for detection of volatile components in water pollution, as a dimethyl disulphide or dimethyl diselenide or sulphur. Therefore, the results provide evidence that odor information can be recognized with around 86% efficiency, detecting smells unwanted in the water and improving the quality control in bottled water factories.

  8. The nose shape as a predictor of maxillary central and lateral incisor width.

    Science.gov (United States)

    Sülün, Tonguç; Ergin, Ugur; Tuncer, Necat

    2005-09-01

    One of the primary aspects of complete denture prosthodontics is determining the correct proportion for the maxillary central incisor width to the lateral incisor width. It has been suggested that the anatomy of the patient's nose is a reliable guide for deciding this ratio. The aim of this study was to test the hypothesis about the relationship between the shape of the nose and the proportion of the central incisor width (CIW) to the lateral incisor width (LIW). The CIW and LIW from a total of 138 subjects (73 males, 65 females) were measured intraorally. The interalar width (IAW) and the width of the root of the nose (WRN) were measured on standard photographs of the subjects. Spearman's rho test was used to analyze the correlation between the proportions of the CIW to the LIW and the IAW to the WRN. The Mann-Whitney Utest was applied to test for any possible gender differences. The IAW, the WRN, and the nose angle (NA) were statistically significantly wider in male subjects than in female subjects. The correlation between IAW/WRN, NA, and CIW/LIW was statistically significant only in female subjects. In the general population, the only statistically significant relationship was between CIW/LIW on the left side and IAW/WRN. Within the results of the IAW, WRN, and NA measurements, we suggest that males have wider, more triangular-shaped noses than females. The proportion of IAW to WRN seems to be a reliable guide for deciding the proportion of the maxillary central incisor width to the lateral incisor.

  9. Congenital absence of the nose: a case report and literature review

    International Nuclear Information System (INIS)

    Olsen, Oe.E.; Rosendahl, K.; Gjelland, K.; Reigstad, H.

    2001-01-01

    A case of congenital absence of the nose is presented. The etiology of this rare condition is unknown. A review of the literature reveals that the previously applied terms, e. g. 'arhinia', are unclear. In the reviewed cases there seems to be a pattern of facial anomalies associated with nasal absence. In most cases, one could probably expect a lack of the olfactory bulbs and tracts. We suggest a new terminology and summarize the aims of the radiological evaluation of this condition. (orig.)

  10. Isothermal-isobaric Nose-Hoover method application: correlation length and disclinations per particle

    International Nuclear Information System (INIS)

    Morales, J.J.; Nuevo, J.M.; Rull, L.F.

    1987-01-01

    The new isothermic-isobaric MD(T,p,N) method of Nose and Hoover is applied in Molecular Dynamics simulations to both liquid and solid near the phase transition. We tested for an appropriate value of the isobaric friction coefficient before calculating the correlation length in the liquid and the disclinations per particle in solid on a big system of 2304 particles. The results are compared with those obtained by traditional MD simulation (E,V,N). (author)

  11. Least Squares Neural Network-Based Wireless E-Nose System Using an SnO₂ Sensor Array.

    Science.gov (United States)

    Shahid, Areej; Choi, Jong-Hyeok; Rana, Abu Ul Hassan Sarwar; Kim, Hyun-Seok

    2018-05-06

    Over the last few decades, the development of the electronic nose (E-nose) for detection and quantification of dangerous and odorless gases, such as methane (CH₄) and carbon monoxide (CO), using an array of SnO₂ gas sensors has attracted considerable attention. This paper addresses sensor cross sensitivity by developing a classifier and estimator using an artificial neural network (ANN) and least squares regression (LSR), respectively. Initially, the ANN was implemented using a feedforward pattern recognition algorithm to learn the collective behavior of an array as the signature of a particular gas. In the second phase, the classified gas was quantified by minimizing the mean square error using LSR. The combined approach produced 98.7% recognition probability, with 95.5 and 94.4% estimated gas concentration accuracies for CH₄ and CO, respectively. The classifier and estimator parameters were deployed in a remote microcontroller for the actualization of a wireless E-nose system.

  12. Surgical Considerations in the Management of Tumours of the Nose ...

    African Journals Online (AJOL)

    BACKGROUND: Tumours of the nose and paranasal sinuses in sub-Saharan Africa are generally characterised by late presentation posing management challenges to the otorhinolaryngologists in the sub-region. OBJECTIVES: To appraise surgical considerations in the management of tumours of the nose and paranasal ...

  13. Enterobius vermicularis in the nose: A rare entity

    OpenAIRE

    Kaniyur, Vishnu; Chandra Prasad, Kishore H.; Devan, P. P.; Doddamani, S. S.; Balachandran, Bharati; Kulkarni, Vikram

    2005-01-01

    A rare case of enterobius vermicularis pin-worm is reported in the nose. An 11-year-old girl presented with the vague symptoms of crawling sensation in the nose for few weeks, who had received treatment for allergic rhinitis. The nasal secretions were examined and confirmed the diagnosis of pinworm infection and treated by albendazole.

  14. Economic Evaluation pf Antibacterial Usage in Ear, Nose and Throat ...

    African Journals Online (AJOL)

    Purpose: To carry out economic evaluation of antibacterial usage for Ear, Nose and Throat infections in a tertiary health care facility in Nigeria. Methods: Antibacterial utilisation evaluation was carried out retrospectively over one year period by reviewing 122 case notes containing 182 prescriptions of patient with Ear Nose ...

  15. The New Star, the New Nose: Tycho Brahe's Nasal Prosthesis

    DEFF Research Database (Denmark)

    Østermark-Johansen, Lene

    2017-01-01

    Tycho Brahe’s loss of part of his nose in a duel has become an important part of his afterlife. The exact nature of his nasal prosthesis–of brass, gold, or silver–remains an enigma, not even solved at his exhumation in 2010. This essay discusses the materiality of Brahe’s new nose...

  16. Holdaway's analysis of the nose prominence of an adult Nigerian ...

    African Journals Online (AJOL)

    The nose prominence was assessed using Holdaway's analysis. Twenty radiographs randomly selected, were retraced to assess for errors. Data analysis included descriptive statistics, Student's t‑tests and analysis of variance using the Statistical Package for Social Sciences. Results: The mean value recorded for the nose ...

  17. Conceptual Design of Deployment Structure of Morphing Nose Cone

    Directory of Open Access Journals (Sweden)

    Junlan Li

    2013-01-01

    Full Text Available For a reusable space vehicle or a missile, the shape of the nose cone has a significant effect on the drag of the vehicle. In this paper, the concept of morphing nose cone is proposed to reduce the drag when the reentry vehicle flies back into the atmosphere. The conceptual design of the structure of morphing nose cone is conducted. Mechanical design and optimization approach are developed by employing genetic algorithm to find the optimal geometric parameters of the morphing structure. An example is analyzed by using the proposed method. The results show that optimal solution supplies the minimum position error. The concept of morphing nose cone will provide a novel way for the drag reduction of reentry vehicle. The proposed method could be practically used for the design and optimization of the deployable structure of morphing nose cone.

  18. Benefits of applying a proxy eligibility period when using electronic health records for outcomes research: a simulation study.

    Science.gov (United States)

    Yu, Tzy-Chyi; Zhou, Huanxue

    2015-06-09

    Electronic health records (EHRs) can provide valuable data for outcomes research. However, unlike administrative claims databases, EHRs lack eligibility tables or a standard way to define the benefit coverage period, which could lead to underreporting of healthcare utilization or outcomes, and could result in surveillance bias. We tested the effect of using a proxy eligibility period (eligibility proxy) when estimating a range of health resource utilization and outcomes parameters under varying degrees of missing encounter data. We applied an eligibility proxy to create a benchmark cohort of chronic obstructive pulmonary disease (COPD) patients with 12 months of follow-up, with the assumption of no missing encounter data. The benchmark cohort provided parameter estimates for comparison with 9,000 simulated datasets representing 10-90% of COPD patients (by 10th percentiles) with between 1 and 11 months of continuous missing data. Two analyses, one for datasets using an eligibility proxy and one for those without an eligibility proxy, were performed on the 9,000 datasets to assess estimator performance under increasing levels of missing data. Estimates for each study variable were compared with those from the benchmark dataset, and performance was evaluated using bias, percentage change, and root-mean-square error. The benchmark dataset contained 6,717 COPD patients, whereas the simulated datasets where the eligibility proxy was applied had between 671 and 6,045 patients depending on the percentage of missing data. Parameter estimates had better performance when an eligibility proxy based on the first and last month of observed activity was applied. This finding was consistent across a range of variables representing patient comorbidities, symptoms, outcomes, health resource utilization, and medications, regardless of the measures of performance used. Without the eligibility proxy, all evaluated parameters were consistently underestimated. In a large COPD patient

  19. The Fabrication of Non-Implant 3D Printed Nose

    Directory of Open Access Journals (Sweden)

    Chuan Yong Leng

    2018-01-01

    Full Text Available Non-surgical rhinoplasty procedures which involves the use of injectable derma fillers are highly risky as patients are susceptible to side effects and complications that may cause unwanted changes in their appearance. This research explores an alternative method of non-surgical rhinoplasty for patients seeking augmentation of the nose with the use of three-dimensional (3D printing. Most rhinoplasty procedures are conducted with the intention of enhancing the aesthetical features of the nose, a 3D model nose was designed based on the combination of the average and the ideal aesthetic parameters of the Northern European Caucasians and South Asia Chinese nose. The modelling of nose is done using the SolidWorks CAD software. An initial design was sketched in a polygon mesh form and further improved on. Different printing materials and infill densities were compared to determine the suitable printing technique. The final nose model is then printed using the Ultimaker 3D printer using Polylactic acid (PLA with an infill density of 100% at a thickness of 1.4 mm. An inner layer to the 3D printed nose was developed for comfortable attachment of the nose model to human skin. The inner layer was fabricated using agar gelatine. Experiments were carried out to increase the strength and adhesiveness of the gelatine so that it could adhere to the human skin and the PLA surface. Tensile and adhesive strength tests were carried out to determine the suitable gel composition for the attachment of the nose to the user’s face. The key outcome from the experiments using natural gelatine was capability of gel to act as an inner layer for the temporary attachment of the 3D nose model to the human skin

  20. Text mining applied to electronic cardiovascular procedure reports to identify patients with trileaflet aortic stenosis and coronary artery disease.

    Science.gov (United States)

    Small, Aeron M; Kiss, Daniel H; Zlatsin, Yevgeny; Birtwell, David L; Williams, Heather; Guerraty, Marie A; Han, Yuchi; Anwaruddin, Saif; Holmes, John H; Chirinos, Julio A; Wilensky, Robert L; Giri, Jay; Rader, Daniel J

    2017-08-01

    Interrogation of the electronic health record (EHR) using billing codes as a surrogate for diagnoses of interest has been widely used for clinical research. However, the accuracy of this methodology is variable, as it reflects billing codes rather than severity of disease, and depends on the disease and the accuracy of the coding practitioner. Systematic application of text mining to the EHR has had variable success for the detection of cardiovascular phenotypes. We hypothesize that the application of text mining algorithms to cardiovascular procedure reports may be a superior method to identify patients with cardiovascular conditions of interest. We adapted the Oracle product Endeca, which utilizes text mining to identify terms of interest from a NoSQL-like database, for purposes of searching cardiovascular procedure reports and termed the tool "PennSeek". We imported 282,569 echocardiography reports representing 81,164 individuals and 27,205 cardiac catheterization reports representing 14,567 individuals from non-searchable databases into PennSeek. We then applied clinical criteria to these reports in PennSeek to identify patients with trileaflet aortic stenosis (TAS) and coronary artery disease (CAD). Accuracy of patient identification by text mining through PennSeek was compared with ICD-9 billing codes. Text mining identified 7115 patients with TAS and 9247 patients with CAD. ICD-9 codes identified 8272 patients with TAS and 6913 patients with CAD. 4346 patients with AS and 6024 patients with CAD were identified by both approaches. A randomly selected sample of 200-250 patients uniquely identified by text mining was compared with 200-250 patients uniquely identified by billing codes for both diseases. We demonstrate that text mining was superior, with a positive predictive value (PPV) of 0.95 compared to 0.53 by ICD-9 for TAS, and a PPV of 0.97 compared to 0.86 for CAD. These results highlight the superiority of text mining algorithms applied to electronic

  1. Detecting cotton boll rot with an electronic nose

    Science.gov (United States)

    South Carolina Boll Rot is an emerging disease of cotton, Gossypium hirsutum L., caused by the opportunistic bacteria, Pantoea agglomerans (Ewing and Fife). Unlike typical fungal diseases, bolls infected with P. agglomerans continue to appear normal externally, complicating early and rapid detectio...

  2. Distribution of adsorbed molecules in electronic nose sensors

    DEFF Research Database (Denmark)

    Swann, M.J.; Glidle, A.; Gadegaard, Nikolaj

    2000-01-01

    Neutron reflectivity measurements of thin films of electropolymerised poly(pyrrole) show that swelling of these insoluble polymers does occur following vapour adsorption. The variation in swelling found for different vapours is correlated with corresponding changes in polymer conductivity and mass...

  3. Investigating white-nose syndrome in bats

    Science.gov (United States)

    Blehert, David S.

    2009-01-01

    A devastating, emergent disease afflicting hibernating bats has pread from the northeast to the mid-Atlantic region of the United States at an alarming rate. Since the winter of 2006-2007, hundreds of thousands of insect-eating bats from at least nine states have died from this new disease, named White-Nose Syndrome (WNS). The disease is named for the white fungus often seen on the muzzles, ears, and wings of bats. This disease poses a threat to cave hibernating bats of the United States and potentially all temperate regions of the world. USGS scientists from the National Wildlife Health Center (NWHC) and the Fort Collins Science Center (FORT), in collaboration with the New York State Department of Environmental Conservation, the U.S. Fish and Wildlife Service, and others have linked a newly described, cold-loving fungus to WNS.

  4. Grinding arrangement for ball nose milling cutters

    Science.gov (United States)

    Burch, C. F. (Inventor)

    1974-01-01

    A grinding arrangement for spiral fluted ball nose end mills and like tools includes a tool holder for positioning the tool relative to a grinding wheel. The tool is mounted in a spindle within the tool holder for rotation about its centerline and the tool holder is pivotably mounted for angular movement about an axis which intersects that centerline. A follower arm of a cam follower secured to the spindle cooperates with a specially shaped cam to provide rotation of the tool during the angular movement of the tool holder during the grinding cycle, by an amount determined by the cam profile. In this way the surface of the cutting edge in contact with the grinding wheel is maintained at the same height on the grinding wheel throughout the angular movement of the tool holder during the grinding cycle.

  5. Primary nasal tuberculosis following blunt trauma nose

    Directory of Open Access Journals (Sweden)

    Kaushik Saha

    2014-01-01

    Full Text Available Primary nasal tuberculosis is a rare disease with nearly 40 cases reported. Our patient was a young male presented with left sided nasal obstruction, anosmia and occasional epistaxis for last 7 weeks after 6 months of blunt trauma nose. Contrast enhanced computed tomography of the para nasal sinuses showed increased soft-tissue density with contrast enhancement in the left maxillary antrum with extension through left osteomeatal foramen to the left nasal cavity along with further extension through choana to nasopharynx resulting in partial obliteration of the nasopharyngeal airway. Nasal endoscopy revealed a sessile polypoidal pinkish mass arising from the left osteomeatal foramen. Histopathological examination of excisional biopsy of that area showed caseating granuloma. Our patient diagnosed as primary nasal tuberculosis following trauma and treated with anti-tubercular chemotherapy.

  6. The Pediatric Emergency Care Applied Research Network Registry: A Multicenter Electronic Health Record Registry of Pediatric Emergency Care.

    Science.gov (United States)

    Deakyne Davies, Sara J; Grundmeier, Robert W; Campos, Diego A; Hayes, Katie L; Bell, Jamie; Alessandrini, Evaline A; Bajaj, Lalit; Chamberlain, James M; Gorelick, Marc H; Enriquez, Rene; Casper, T Charles; Scheid, Beth; Kittick, Marlena; Dean, J Michael; Alpern, Elizabeth R

    2018-04-01

    Electronic health record (EHR)-based registries allow for robust data to be derived directly from the patient clinical record and can provide important information about processes of care delivery and patient health outcomes.  A data dictionary, and subsequent data model, were developed describing EHR data sources to include all processes of care within the emergency department (ED). ED visit data were deidentified and XML files were created and submitted to a central data coordinating center for inclusion in the registry. Automated data quality control occurred prior to submission through an application created for this project. Data quality reports were created for manual data quality review.  The Pediatric Emergency Care Applied Research Network (PECARN) Registry, representing four hospital systems and seven EDs, demonstrates that ED data from disparate health systems and EHR vendors can be harmonized for use in a single registry with a common data model. The current PECARN Registry represents data from 2,019,461 pediatric ED visits, 894,503 distinct patients, more than 12.5 million narrative reports, and 12,469,754 laboratory tests and continues to accrue data monthly.  The Registry is a robust harmonized clinical registry that includes data from diverse patients, sites, and EHR vendors derived via data extraction, deidentification, and secure submission to a central data coordinating center. The data provided may be used for benchmarking, clinical quality improvement, and comparative effectiveness research. Schattauer.

  7. Characterization and Differentiation of Petroleum-Derived Products by E-Nose Fingerprints

    Directory of Open Access Journals (Sweden)

    Marta Ferreiro-González

    2017-11-01

    Full Text Available Characterization of petroleum-derived products is an area of continuing importance in environmental science, mainly related to fuel spills. In this study, a non-separative analytical method based on E-Nose (Electronic Nose is presented as a rapid alternative for the characterization of several different petroleum-derived products including gasoline, diesel, aromatic solvents, and ethanol samples, which were poured onto different surfaces (wood, cork, and cotton. The working conditions about the headspace generation were 145 °C and 10 min. Mass spectroscopic data (45–200 m/z combined with chemometric tools such as hierarchical cluster analysis (HCA, later principal component analysis (PCA, and finally linear discriminant analysis (LDA allowed for a full discrimination of the samples. A characteristic fingerprint for each product can be used for discrimination or identification. The E-Nose can be considered as a green technique, and it is rapid and easy to use in routine analysis, thus providing a good alternative to currently used methods.

  8. On the Temporal Stability of Analyte Recognition with an E-Nose Based on a Metal Oxide Sensor Array in Practical Applications.

    Science.gov (United States)

    Kiselev, Ilia; Sysoev, Victor; Kaikov, Igor; Koronczi, Ilona; Adil Akai Tegin, Ruslan; Smanalieva, Jamila; Sommer, Martin; Ilicali, Coskan; Hauptmannl, Michael

    2018-02-11

    The paper deals with a functional instability of electronic nose (e-nose) units which significantly limits their real-life applications. Here we demonstrate how to approach this issue with example of an e-nose based on a metal oxide sensor array developed at the Karlsruhe Institute of Technology (Germany). We consider the instability of e-nose operation at different time scales ranging from minutes to many years. To test the e-nose we employ open-air and headspace sampling of analyte odors. The multivariate recognition algorithm to process the multisensor array signals is based on the linear discriminant analysis method. Accounting for the received results, we argue that the stability of device operation is mostly affected by accidental changes in the ambient air composition. To overcome instabilities, we introduce the add-training procedure which is found to successfully manage both the temporal changes of ambient and the drift of multisensor array properties, even long-term. The method can be easily implemented in practical applications of e-noses and improve prospects for device marketing.

  9. [Basal cell carcinoma of the nose].

    Science.gov (United States)

    Bonvallot, T; Raulo, Y; Zeller, J; Faivre, J M; Horn, G; Baruch, J

    1993-01-01

    The purpose of this study of 81 patients with basal cell carcinoma (BCC) of the nose was to present the oncological and cosmetic results of surgical treatment and compare these results with those of other possible treatments. We report a series of 81 cases of histologically proven BCC of the nose located chiefly on the alae nasi and on the lower end of this organ; 42 p. 100 of the tumors had previously been treated and had recurred. The patients' mean age was 63 years, and the shortest follow-up was 3 years. Excision of the tumor under simple or reinforced local anaesthesia was complete in 88 p. 100 of the cases, incomplete or borderline in 12 p. 100 and systematically repeated. Extemporaneous histological examination was performed in 18 p. 100 of the cases. The operative lesion was repaired with a graft or a flap. There was no postsurgical treatment. The recurrence rate was 4 p. 100 with a minimum follow-up of 3 years. The cosmetic result was good in 78 p. 100 of the patients. Numerous treatments have been used against BCC of the nose, the results, advantages and disadvantages of each of these treatments are given below: 1. Cryosurgery. The problem with this method is that it is relatively difficult to perform and requires reliable operators. The cure rate is similar to that of other treatments. 2. Chemotherapy is not frequently used. 3. Electrocoagulation. Contrary to the conventional excision, this method precludes all histological controls, and the common idea of good oncological results is now being revised. 4. Radiotherapy. The recurrence rate varies from 7 to 11.8 p. 100 with fair cosmetic results. It requires numerous sessions, cannot be repeated in case of recurrence and complicates the surgical treatment. In addition, there is a long-term risk of radiodystrophy. 5. Curietherapy by local implantation of 192Iridium has a recurrence rate of 2.5 to 7 p. 100. This treatment requires hospitalization and is costly. It is indicated in cases of complex surgery

  10. [Integration of fundamental and applied medical and technical research made at the department of the biomedical systems, Moscow State Institute of Electronic Engineering].

    Science.gov (United States)

    Selishchev, S V

    2004-01-01

    The integration results of fundamental and applied medical-and-technical research made at the chair of biomedical systems, Moscow state institute of electronic engineering (technical university--MSIEE), are described in the paper. The chair is guided in its research activity by the traditions of higher education in Russia in the field of biomedical electronics and biomedical engineering. Its activities are based on the extrapolation of methods of electronic tools, computer technologies, physics, biology and medicine with due respect being paid to the requirements of practical medicine and to topical issues of research and design.

  11. Impacts of Deflection Nose on Ballistic Trajectory Control Law

    Directory of Open Access Journals (Sweden)

    Bo Zhang

    2014-01-01

    Full Text Available The deflection of projectile nose is aimed at changing the motion of the projectile in flight with the theory of motion control and changing the exterior ballistics so as to change its range and increase its accuracy. The law of external ballistics with the deflectable nose is considered as the basis of the design of a flight control system and an important part in the process of projectile development. Based on the existing rigid external ballistic model, this paper establishes an external ballistic calculation model for deflectable nose projectile and further establishes the solving programs accordingly. Different angle of attack, velocity, coefficients of lift, resistance, and moment under the deflection can be obtained in this paper based on the previous experiments and emulation researches. In the end, the author pointed out the laws on the impaction of external ballistic trajectory by the deflection of nose of the missile.

  12. Histopathology confirms white-nose syndrome in bats in Europe.

    Science.gov (United States)

    Pikula, Jiri; Bandouchova, Hana; Novotny, Ladislav; Meteyer, Carol U; Zukal, Jan; Irwin, Nancy R; Zima, Jan; Martínková, Natália

    2012-01-01

    White-nose syndrome, associated with the fungal skin infection geomycosis, caused regional population collapse in bats in North America. Our results, based on histopathology, show the presence of white-nose syndrome in Europe. Dermatohistopathology on two bats (Myotis myotis) found dead in March 2010 with geomycosis in the Czech Republic had characteristics resembling Geomyces destructans infection in bats confirmed with white-nose syndrome in US hibernacula. In addition, a live M. myotis, biopsied for histopathology during hibernation in April 2011, had typical fungal infection with cupping erosion and invasion of muzzle skin diagnostic for white-nose syndrome and conidiospores identical to G. destructans that were genetically confirmed as G. destructans.

  13. Histopathology confirms white-nose syndrome in bats in Europe

    Science.gov (United States)

    Pikula, J.; Bandouchova, H.; Novotny, L.; Meteyer, C.U.; Zukal, J.; Irwin, N.R.; Zima, J.; Martinkova, N.

    2012-01-01

    White-nose syndrome, associated with the fungal skin infection geomycosis, caused regional population collapse in bats in North America. Our results, based on histopathology, show the presence of white-nose syndrome in Europe. Dermatohistopathology on two bats (Myotis myotis) found dead in March 2010 with geomycosis in the Czech Republic had characteristics resembling Geomyces destructans infection in bats confirmed with white-nose syndrome in US hibernacula. In addition, a live M. myotis, biopsied for histopathology during hibernation in April 2011, had typical fungal infection with cupping erosion and invasion of muzzle skin diagnostic for white-nose syndrome and conidiospores identical to G. destructans that were genetically confirmed as G. destructans. ?? Wildlife Disease Association 2012.

  14. Reproductive ecology of Commerson's leaf-nosed bats ...

    African Journals Online (AJOL)

    Reproductive ecology of Commerson's leaf-nosed bats Hipposideros commersoni ... Reproductive females dispersed twice during the annual cycle, while in ... Synchronized parturitions within maternity roosts (in late October) created a hot, ...

  15. White-Nose Syndrome Fungus (Geomyces destructans) in Bats, Europe

    OpenAIRE

    Wibbelt, Gudrun; Kurth, Andreas; Hellmann, David; Weishaar, Manfred; Barlow, Alex; Veith, Michael; Prüger, Julia; Görföl, Tamás; Grosche, Lena; Bontadina, Fabio; Zöphel, Ulrich; Seidl, Hans-Peter; Cryan, Paul M.; Blehert, David S.

    2010-01-01

    White-nose syndrome is an emerging disease in North America that has caused substantial declines in hibernating bats. A recently identified fungus (Geomyces destructans) causes skin lesions that are characteristic of this disease. Typical signs of this infection were not observed in bats in North America before white-nose syndrome was detected. However, unconfirmed reports from Europe indicated white fungal growth on hibernating bats without associated deaths. To investigate these differences...

  16. Diagnostic imaging of the nose and paranasal sinuses

    International Nuclear Information System (INIS)

    Lloyd, G.A.S.

    1988-01-01

    This book offers extensively illustrated and comprehensive coverage of diagnostic imaging techniques of the nose and paranasal sinuses. The important feature of the work is the way it correlates histology with CT and MRI and includes magnetic resonance contrast studies using Gadolinium DTPA. Furthermore, it is the first text to treat the imaging of the various types of tumors of the nose and paranasal sinuses on an individual basis

  17. Present and potential distribution of Snub-nosed Monkey

    DEFF Research Database (Denmark)

    Nüchel, Jonas; Bøcher, Peder Klith; Svenning, Jens-Christian

    are the Snub-nosed Monkeys (Rhinopithecus), a temperate-subtropical East Asian genus. We use species distribution modeling to assess the following question of key relevancy for conservation management of Rhinopithecus; 1. Which climatic factors determine the present distribution of Rhinopithecus within...... distribution of Rhinopithecus within the region, considering climate, habitat availability and the locations of nature reserves. Keywords: biodiversity, biogeography, conservation, China, snub-nosed monkey, rhinopithecus, primates, species distribution modeling...

  18. [Severe inflammation of the muzzle caused by a nose ring in a breeding bull].

    Science.gov (United States)

    Braun, U; Gautschi, A; Reichle, S; Gerspach, C

    2010-09-01

    This report describes the findings in a bull with severe inflammation of the muzzle and nose attributable to a nose ring. The most striking finding was that the bull continually licked the right side of the upper lip. The muzzle and right upper lip were swollen, hard, reddened and partially depigmented. Mucopurulent nasal discharge and salivation were also noted, and palpation of the right upper lip was extremely painful. Based on the findings, purulent infection of the right side of the muzzle, right naris and external nasal passage was diagnosed. After removing the nose ring the affected areas were washed daily for four days with a camomile-containing solution after which a chlorhexidine and dexpanthenol salve was applied. The bull also received ceftiofur and ketoprofen. The general condition and appetite of the bull normalised within a few days, and the inflammatory lesions resolved with the exception of the areas of depigmentation. After ten days of treatment, the bull was considered healthy and discharged from the clinic.

  19. Technical basis for using nose swab bioassay data for early internal dose assessment

    International Nuclear Information System (INIS)

    Guilmette, Raymond A.; Bertelli, Luiz; Miller, Guthrie; Little, Tom T.

    2007-01-01

    One of the challenges to the dose assessment team in response to an inhalation incident in the workplace is to provide the occupational physicians, operational radiation protection personnel and line managers with early estimates of radionuclide intakes so that appropriate consequence management and mitigation can be done. For radionuclides such as Pu, where in vivo counting is not adequately sensitive, other techniques such as the measurement of removable radionuclide from the nasal airway passages can be used. At Los Alamos National Laboratory (LANL), nose swabs of the ET 1 region have been used routinely as a first response to airborne Pu releases in the workplace, as well as for other radionuclides. This paper presents the results of analysing over 15 years of nose swab data, comparing these with dose assessments performed using the Bayesian methods developed at LANL. The results provide empirical support for using nose swab data for early dose assessments. For Pu, a rule of thumb is a dose factor of 0.8 mSv Bq -1 , assuming a linear relationship between nasal swab activity and committed effective dose equivalent. However, this value is specific to the methods and models used at LANL, and should not be applied directly without considering possible differences in measurement and calculation methods. (authors)

  20. The spectacular human nose: an amplifier of individual quality?

    Directory of Open Access Journals (Sweden)

    Åse Kristine Rognmo Mikalsen

    2014-04-01

    Full Text Available Amplifiers are signals that improve the perception of underlying differences in quality. They are cost free and advantageous to high quality individuals, but disadvantageous to low quality individuals, as poor quality is easier perceived because of the amplifier. For an amplifier to evolve, the average fitness benefit to the high quality individuals should be higher than the average cost for the low quality individuals. The human nose is, compared to the nose of most other primates, extraordinary large, fragile and easily broken—especially in male–male interactions. May it have evolved as an amplifier among high quality individuals, allowing easy assessment of individual quality and influencing the perception of attractiveness? We tested the latter by manipulating the position of the nose tip or, as a control, the mouth in facial pictures and had the pictures rated for attractiveness. Our results show that facial attractiveness failed to be influenced by mouth manipulations. Yet, facial attractiveness increased when the nose tip was artificially centered according to other facial features. Conversely, attractiveness decreased when the nose tip was displaced away from its central position. Our results suggest that our evaluation of attractiveness is clearly sensitive to the centering of the nose tip, possibly because it affects our perception of the face’s symmetry and/or averageness. However, whether such centering is related to individual quality remains unclear.

  1. XRAY applied program package for calculation of electron-photon fields in the energy range of 1-1000 keV

    International Nuclear Information System (INIS)

    Lappa, A.V.; Khadyeva, Z.M.; Burmistrov, D.S.; Vasil'ev, O.N.

    1990-01-01

    The package of applied XRAY programs is intended for calculating the linear and fluctuation characteristics of photon and electron radiation fields in heterogeneous medium within 1-1000 keV energy range. The XRAY program package consists of moduli written in FORTRAN-IV and data files. 9 refs

  2. Theseus Nose and Pod Cones Being Unloaded

    Science.gov (United States)

    1996-01-01

    Crew members are seen here unloading the nose and pod cones of the Theseus prototype research aircraft at NASA's Dryden Flight Research Center, Edwards, California, in May of 1996. The Theseus aircraft, built and operated by Aurora Flight Sciences Corporation, Manassas, Virginia, was a unique aircraft flown at NASA's Dryden Flight Research Center, Edwards, California, under a cooperative agreement between NASA and Aurora. Dryden hosted the Theseus program, providing hangar space and range safety for flight testing. Aurora Flight Sciences was responsible for the actual flight testing, vehicle flight safety, and operation of the aircraft. The Theseus remotely piloted aircraft flew its maiden flight on May 24, 1996, at Dryden. During its sixth flight on November 12, 1996, Theseus experienced an in-flight structural failure that resulted in the loss of the aircraft. As of the beginning of the year 2000, Aurora had not rebuilt the aircraft. Theseus was built for NASA under an innovative, $4.9 million fixed-price contract by Aurora Flight Sciences Corporation and its partners, West Virginia University, Morgantown, West Virginia, and Fairmont State College, Fairmont, West Virginia. The twin-engine, unpiloted vehicle had a 140-foot wingspan, and was constructed largely of composite materials. Powered by two 80-horsepower, turbocharged piston engines that drove twin 9-foot-diameter propellers, Theseus was designed to fly autonomously at high altitudes, with takeoff and landing under the active control of a ground-based pilot in a ground control station 'cockpit.' With the potential ability to carry 700 pounds of science instruments to altitudes above 60,000 feet for durations of greater than 24 hours, Theseus was intended to support research in areas such as stratospheric ozone depletion and the atmospheric effects of future high-speed civil transport aircraft engines. Instruments carried aboard Theseus also would be able to validate satellite-based global environmental

  3. Classification of E-Nose Aroma Data of Four Fruit Types by ABC-Based Neural Network.

    Science.gov (United States)

    Adak, M Fatih; Yumusak, Nejat

    2016-02-27

    Electronic nose technology is used in many areas, and frequently in the beverage industry for classification and quality-control purposes. In this study, four different aroma data (strawberry, lemon, cherry, and melon) were obtained using a MOSES II electronic nose for the purpose of fruit classification. To improve the performance of the classification, the training phase of the neural network with two hidden layers was optimized using artificial bee colony algorithm (ABC), which is known to be successful in exploration. Test data were given to two different neural networks, each of which were trained separately with backpropagation (BP) and ABC, and average test performances were measured as 60% for the artificial neural network trained with BP and 76.39% for the artificial neural network trained with ABC. Training and test phases were repeated 30 times to obtain these average performance measurements. This level of performance shows that the artificial neural network trained with ABC is successful in classifying aroma data.

  4. Making oxidation potentials predictable: Coordination of additives applied to the electronic fine tuning of an iron(II) complex

    KAUST Repository

    Haslinger, Stefan

    2014-11-03

    This work examines the impact of axially coordinating additives on the electronic structure of a bioinspired octahedral low-spin iron(II) N-heterocyclic carbene (Fe-NHC) complex. Bearing two labile trans-acetonitrile ligands, the Fe-NHC complex, which is also an excellent oxidation catalyst, is prone to axial ligand exchange. Phosphine- and pyridine-based additives are used for substitution of the acetonitrile ligands. On the basis of the resulting defined complexes, predictability of the oxidation potentials is demonstrated, based on a correlation between cyclic voltammetry experiments and density functional theory calculated molecular orbital energies. Fundamental insights into changes of the electronic properties upon axial ligand exchange and the impact on related attributes will finally lead to target-oriented manipulation of the electronic properties and consequently to the effective tuning of the reactivity of bioinspired systems.

  5. Making oxidation potentials predictable: Coordination of additives applied to the electronic fine tuning of an iron(II) complex

    KAUST Repository

    Haslinger, Stefan; Kü ck, Jens W.; Hahn, Eva M.; Cokoja, Mirza; Pö thig, Alexander; Basset, Jean-Marie; Kü hn, Fritz

    2014-01-01

    This work examines the impact of axially coordinating additives on the electronic structure of a bioinspired octahedral low-spin iron(II) N-heterocyclic carbene (Fe-NHC) complex. Bearing two labile trans-acetonitrile ligands, the Fe-NHC complex, which is also an excellent oxidation catalyst, is prone to axial ligand exchange. Phosphine- and pyridine-based additives are used for substitution of the acetonitrile ligands. On the basis of the resulting defined complexes, predictability of the oxidation potentials is demonstrated, based on a correlation between cyclic voltammetry experiments and density functional theory calculated molecular orbital energies. Fundamental insights into changes of the electronic properties upon axial ligand exchange and the impact on related attributes will finally lead to target-oriented manipulation of the electronic properties and consequently to the effective tuning of the reactivity of bioinspired systems.

  6. Nose micro-blowing for asymmetric vortices control on blunt-nose slender body at high angle of attack

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2017-11-01

    Full Text Available The asymmetric vortices over blunt-nose slender body at high angles of attack result in random side force. In this paper, a nose micro-blowing technology is used to control the asymmetric flow. Pressure measurement and particle image velocimetry (PIV experiments are conducted in a low-speed wind tunnel to research effects of jet flow rate on asymmetric vortices over blunt-nose slender body. The angle of attack of the model is fixed at 50° and the Reynolds number for the experiments is 1.6×10 5 based on diameter of aftbody. A blow hole (5 mm in diameter on the nose is processed at circumferential angle θb= 90° and meridian angle γb= 20° with jet momentum ratio Cμ ranging from 5.30×10-7 to 1.19×10−4. Tests are made under two kinds of perturbations. One is called single perturbation with only blow hole and the other is called combined perturbation consists of blow hole and additional granules set on nose. The results show that whether the model has the single perturbation or the combined one, the sectional side force of x/D = 3 varies in the same direction with the increasement of Cμ and remains stable when Cμ is greater than 3.29×10−6. But the stable force values are different according to various perturbations. The fact proves that the size and direction of the side force of blunt-nose slender body can be controlled by the nose micro-blowing.

  7. A rigorous nonorthogonal configuration interaction approach for the calculation of electronic couplings between diabatic states applied to singlet fission

    NARCIS (Netherlands)

    Wibowo, Meilani; Broer, Ria; Havenith, Remco W. A.

    2017-01-01

    For the design of efficient singlet fission chromophores, knowledge of the factors that govern the singlet fission rate is important. This rate is approximately proportional to the electronic coupling between the lowest (diabatic) spin singlet state that is populated following photoexcitation state

  8. A green-LED driven source of hydrated electrons characterized from microseconds to hours and applied to cross couplings.

    Science.gov (United States)

    Naumann, Robert; Goez, Martin

    2018-03-12

    We present a novel photoredox catalytic system that delivers synthetically useable concentrations of hydrated electrons when illuminated with a green light-emitting diode (LED). The catalyst is a ruthenium complex protected by an anionic micelle, and the urate dianion serves as sacrificial donor confined to the aqueous bulk. Through its chemical properties, that donor not only suppresses charge recombination that would limit the electron yield but also enables this system to perform cross couplings via hydrated electrons, for which we report the first examples. We have investigated the kinetics of all the steps involving the electron and its direct precursor in a comparative study by using laser flash photolysis and by monitoring product formation during LED photolysis. Despite the differences in timescales, each approach on its own already gives a complete picture of the reaction over a temporal range ten orders of magnitude wide. Noticeable discrepancies between the kinetic parameters obtained with the two complementary techniques can be rationalized with the slow secondary chemistry of the system; they reveal that the product-based method provides a more accurate description because it responds also to the changes of the system composition during a synthesis; hence, they demonstrate that in complex systems the timescale of the experimental observation should be matched to that of the actual application. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Electronic Health Records: Applying Diffusion of Innovation Theory to the Relationship between Multifactor Authentication and EHR Adoption

    Science.gov (United States)

    Lockett, Daeron C.

    2014-01-01

    Electronic Health Record (EHR) systems are increasingly becoming accepted as future direction of medical record management systems. Programs such as the American Recovery and Reinvestment Act have provided incentives to hospitals that adopt EHR systems. In spite of these incentives, the perception of EHR adoption is that is has not achieved the…

  10. [The crooked nose: correction of dorsal and caudal septal deviations].

    Science.gov (United States)

    Foda, H M T

    2010-09-01

    The deviated nose represents a complex cosmetic and functional problem. Septal surgery plays a central role in the successful management of the externally deviated nose. This study included 800 patients seeking rhinoplasty to correct external nasal deviations; 71% of these suffered from variable degrees of nasal obstruction. Septal surgery was necessary in 736 (92%) patients, not only to improve breathing, but also to achieve a straight, symmetric external nose. A graduated surgical approach was adopted to allow correction of the dorsal and caudal deviations of the nasal septum without weakening its structural support to the nasal dorsum or nasal tip. The approach depended on full mobilization of deviated cartilage, followed by straightening of the cartilage and its fixation in the corrected position by using bony splinting grafts through an external rhinoplasty approach.

  11. Distorted wave models applied to electron emission study in ion-atom collisions at intermediate and high energies

    International Nuclear Information System (INIS)

    Fainstein, P.D.

    1989-01-01

    The electron emission from different atoms induced by impact of multicharged bare ions at intermediate and high energies is studied. To perform these studies, the continuum distorted wave-eikonal initial state model is used. With this distorted wave model, analytical expressions are obtained for the transition amplitudes as a function of the transverse momentum transfer for hydrogen targets in an arbitrary initial state and for every any orbital of a multielectronic target represented as a linear combination of Slater type orbitals. With these expressions, the different cross sections which are compared with the experimental data available are numerically calculated. The results obtained for different targets and projectiles and the comparison with other theoretical models and experimental data allows to explain the electron emission spectra and to predict new effects which have not been measured so far. The results of the present work permit to view the ionization process as the evolution of the active electron in the combined field of the target and projectile nuclei. (Author) [es

  12. Applied superconductivity

    CERN Document Server

    Newhouse, Vernon L

    1975-01-01

    Applied Superconductivity, Volume II, is part of a two-volume series on applied superconductivity. The first volume dealt with electronic applications and radiation detection, and contains a chapter on liquid helium refrigeration. The present volume discusses magnets, electromechanical applications, accelerators, and microwave and rf devices. The book opens with a chapter on high-field superconducting magnets, covering applications and magnet design. Subsequent chapters discuss superconductive machinery such as superconductive bearings and motors; rf superconducting devices; and future prospec

  13. A universal electronical adaptation of automats for biochemical analysis to a central processing computer by applying CAMAC-signals

    International Nuclear Information System (INIS)

    Schaefer, R.

    1975-01-01

    A universal expansion of a CAMAC-subsystem - BORER 3000 - for adapting analysis instruments in biochemistry to a processing computer is described. The possibility of standardizing input interfaces for lab instruments with such circuits is discussed and the advantages achieved by applying the CAMAC-specifications are described

  14. Necrotizing Fasciitis of the Nose Complicated with Cavernous Sinus Thrombosis

    Directory of Open Access Journals (Sweden)

    D. Swaminath

    2014-01-01

    Full Text Available Necrotizing fasciitis is a rapidly progressive life threatening bacterial infection of the skin, the subcutaneous tissue, and the fascia. We present a case of necrotizing fasciitis involving the nose complicated by cavernous sinus thrombosis. Few cases of septic cavernous sinus thrombosis have been reported to be caused by cellulitis of the face but necrotizing fasciitis of the nose is rare. It is very important to recognize the early signs of cavernous thrombosis. Treatment for septic cavernous sinus thrombosis is controversial but early use of empirical antibiotics is imperative.

  15. Angioendotheliosarcoma of the nose--a case report

    DEFF Research Database (Denmark)

    Waersted, A; Andersen, Klaus Ejner; Hansen, J P

    1984-01-01

    Angioendotheliosarcoma of the face or scalp is regarded as a highly malignant tumor. We present a case with onset as a purple macule on the nose, suspected to be rosacea, and emphasize the use of early skin biopsy when a red or purple discoloration is seen in the face of elderly people.......Angioendotheliosarcoma of the face or scalp is regarded as a highly malignant tumor. We present a case with onset as a purple macule on the nose, suspected to be rosacea, and emphasize the use of early skin biopsy when a red or purple discoloration is seen in the face of elderly people....

  16. Utility of electronic hand hygiene counting devices for measuring physicians' hand hygiene adherence applied to outpatient settings.

    Science.gov (United States)

    Arai, Akie; Tanabe, Masaki; Nakamura, Akiko; Yamasaki, Daisuke; Muraki, Yuichi; Kaneko, Toshihiro; Kadowaki, Ayako; Ito, Masaaki

    2016-12-01

    Our objectives were to evaluate the utility of electronic hand hygiene counting devices in outpatient settings and the impact of results feedback on physicians' hand hygiene behaviors. We installed 130 electronic hand hygiene counting devices in our redesigned outpatient department. We remotely monitored physicians' hand hygiene practices during outpatient examinations and calculated the adherence rate as follows: number of hand hygiene counts divided by the number of outpatients examined multiplied by 100. Physician individual adherence rates were also classified into 4 categories. Two hundred and eighty physicians from 28 clinical departments were monitored for 3 months. The overall hand hygiene adherence rate was 10.7% at baseline, which improved significantly after feedback to 18.2% in the third month. Of the clinical departments, 78.6% demonstrated significant improvement in hand hygiene compliance. The change in the percentage of physicians in each category before and after feedback were as follows: very low (84.3% to 72.1%), low (8.6% to 14.3%), moderate (2.9% to 8.9%), and high (4.3% to 4.6%), from the first to third month, respectively. Based on category assessment, 17.1% of physicians were classified as responders. Physicians' adherence to hand hygiene practices during outpatient examinations was successfully monitored remotely using electronic counting devices. Audit and feedback of adherence data may have a positive impact on physicians' hand hygiene compliance. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  17. Analysis of Premature Wear-Out of Aircraft Gun Barrel by Applying a Transmission Electron Microscopy (TEM

    Directory of Open Access Journals (Sweden)

    Łęczycki Krzysztof

    2017-08-01

    Full Text Available Firing from gun armament generates a wide range of physico-chemical phenomena contributing to the degradation of barrel material, e.g. pressure, high temperature, chemically aggressive character of post-detonation gases and friction of a driving band. In this work the technique of thin foils was used in Transmission Electron Microscopy (TEM to study the influence of physicochemical phenomena on the material microstructure of aircraft gun barrel. A mechanism and reason of premature wear-out of the barrel under consideration was also outlined by utilising light microscopy and hardness measurements.

  18. Automation and instrument control applied to an experimental study of electron transport dynamics in an avalanche mode resistive plater chamber

    International Nuclear Information System (INIS)

    Ridenti, Marco A.; Pascholati, Paulo R.

    2009-01-01

    In this work it is presented a computer based instrumentation system which was developed to perform data acquisition and integrate the control of different devices in an experimental study of electron transport dynamics in an avalanche mode resistive plate chamber detector in the Radiation Technology Center (CTR) at IPEN/CNEN-SP. System control and data acquisition was performed by a computer program called RPCLabOperator written in MatLab environment running on a LeCroy WavePro 7000 digital oscilloscope. (author)

  19. Time-dependent reduced density matrix functional theory applied to laser-driven, correlated two-electron dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Brics, Martins; Kapoor, Varun; Bauer, Dieter [Institut fuer Physik, Universitaet Rostock, 18051 Rostock (Germany)

    2013-07-01

    Time-dependent density functional theory (TDDFT) with known and practicable exchange-correlation potentials does not capture highly correlated electron dynamics such as single-photon double ionization, autoionization, or nonsequential ionization. Time-dependent reduced density matrix functional theory (TDRDMFT) may remedy these problems. The key ingredients in TDRDMFT are the natural orbitals (NOs), i.e., the eigenfunctions of the one-body reduced density matrix (1-RDM), and the occupation numbers (OCs), i.e., the respective eigenvalues. The two-body reduced density matrix (2-RDM) is then expanded in NOs, and equations of motion for the NOs can be derived. If the expansion coefficients of the 2-RDM were known exactly, the problem at hand would be solved. In practice, approximations have to be made. We study the prospects of TDRDMFT following a top-down approach. We solve the exact two-electron time-dependent Schroedinger equation for a model Helium atom in intense laser fields in order to study highly correlated phenomena such as the population of autoionizing states or single-photon double ionization. From the exact wave function we calculate the exact NOs, OCs, the exact expansion coefficients of the 2-RDM, and the exact potentials in the equations of motion. In that way we can identify how many NOs and which level of approximations are necessary to capture such phenomena.

  20. Smart storage technologies applied to fresh foods: A review.

    Science.gov (United States)

    Wang, Jingyu; Zhang, Min; Gao, Zhongxue; Adhikari, Benu

    2017-06-30

    Fresh foods are perishable, seasonal and regional in nature and their storage, transportation, and preservation of freshness are quite challenging. Smart storage technologies can online detection and monitor the changes of quality parameters and storage environment of fresh foods during storage, so that operators can make timely adjustments to reduce the loss. This article reviews the smart storage technologies from two aspects: online detection technologies and smartly monitoring technologies for fresh foods. Online detection technologies include electronic nose, nuclear magnetic resonance (NMR), near infrared spectroscopy (NIRS), hyperspectral imaging and computer vision. Smartly monitoring technologies mainly include some intelligent indicators for monitoring the change of storage environment. Smart storage technologies applied to fresh foods need to be highly efficient and nondestructive and need to be competitively priced. In this work, we have critically reviewed the principles, applications, and development trends of smart storage technologies.

  1. Electronics

    Science.gov (United States)

    2001-01-01

    International Acer Incorporated, Hsin Chu, Taiwan Aerospace Industrial Development Corporation, Taichung, Taiwan American Institute of Taiwan, Taipei, Taiwan...Singapore and Malaysia .5 - 4 - The largest market for semiconductor products is the high technology consumer electronics industry that consumes up...Singapore, and Malaysia . A new semiconductor facility costs around $3 billion to build and takes about two years to become operational

  2. 21 CFR 874.4500 - Ear, nose, and throat microsurgical carbon dioxide laser.

    Science.gov (United States)

    2010-04-01

    ... laser. 874.4500 Section 874.4500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND..., nose, and throat microsurgical carbon dioxide laser. (a) Identification. An ear, nose, and throat microsurgical carbon dioxide laser is a device intended for the surgical excision of tissue from the ear, nose...

  3. Determination of Soursop (Annona muricata L. cv. Elita Fruit Volatiles during Ripening by Electronic Nose and Gas Chromatography Coupled to Mass Spectroscopy / Determinación de Compuestos Volátiles en Frutos de Guanábana (Annona muricata L. cv. Elita, d

    Directory of Open Access Journals (Sweden)

    Carlos Julio Márquez Cardozo

    2013-12-01

    highly perishable tropical fruit commercially grown in Colombia, soursop (Annona muricata L. is currently in need of postharvest handling studies. Thus, the present researchwas conducted to characterize the volatile compounds of soursop cv. Elita during postharvest. For this purpose, fruit ripeness wasevaluated, for one thing, by a volatile compound measuring systemknown as electronic nose (EN, and for another thing, by headspacesolid phase microextraction and gas chromatography massspectrometry (HS-SPME/GC-MS. The profile of volatile substancesin fruits is one of the main indicators of the sensory attributes that  typify the organoleptic quality of these products. The EN constitutesan economical, relatively simple, fast and innovative alternative to determine groups of volatile compounds in whole or fractionatedsamples from fruits of commercial interest. In contrast, and despite its being a highly selective technique, the use of SPME/CG-MS might be limited by its elevated cost. Based on EN assessment, fruit ripening stages were classified as unripe, half ripe, ripe and overripe. The most active EN sensors were numbers 2 sensitiveto nitrogen oxides, 6 (sensitive to methane and 8 (sensitive toalcohols and partially aromatic compounds. HS-SPME/GCMS analysis allowed establishing that during postharvest, the major proportion of volatile compounds corresponded to esters, predominantly Methyl hexanoate. Particularly in overripe fruits, the presence of alcoholic compounds coincides with the EN assessment, which, for its part, detected mainly alcohols and a wide range of aromatic substances. The study contributes to the characterization of postharvest volatiles, which are one of themajor sensory attributes of tropical fruits.

  4. Genetic diversity and population structure of leaf-nosed bat ...

    African Journals Online (AJOL)

    Genetic variation and population structure of the leaf-nosed bat Hipposideros speoris were estimated using 16S rRNA sequence and microsatellite analysis. Twenty seven distinct mitochondrial haplotypes were identified from 186 individuals, sampled from eleven populations. FST test revealed significant variations ...

  5. White-Nose Syndrome Fungus (Geomyces destructans) in Bat, France

    Science.gov (United States)

    Puechmaille, Sébastien J.; Verdeyroux, Pascal; Fuller, Hubert; Gouilh, Meriadeg Ar; Bekaert, Michaël

    2010-01-01

    White-nose syndrome is caused by the fungus Geomyces destructans and is responsible for the deaths of >1,000,000 bats since 2006. This disease and fungus had been restricted to the northeastern United States. We detected this fungus in a bat in France and assessed the implications of this finding. PMID:20113562

  6. Ultrasound imaging of the nose in septorhinoplasty patients.

    Science.gov (United States)

    Stenner, Markus; Rudack, Claudia

    2015-10-01

    Detailed preoperative planning based on available clinical information is an essential component of determining septorhinoplasty outcome. In addition to rhinoscopy and airway measurements, preoperative photographs are the only image modalities that are regularly used in septorhinoplasty patients and contribute to the preoperative planning of the surgery. The aim of this study was to evaluate the use of high-resolution ultrasonography in septorhinoplasty patients before surgery and during follow-up. We examined 35 patients before and after open septorhinoplasty using 12- and 15-MHz B-mode, linear array transducer ultrasound in noncontact mode. The patients presented with a variety of different functional and aesthetic problems, and all underwent septorhinoplasty for septal modification, and tip and dorsum refinement. The mean follow-up time for ultrasound after surgery was 4.5 weeks. Soft tissue, cartilaginous, and bony structures of the nose could be well-visualised. In the untreated nose, functional and aesthetic characteristics as well as preoperative anatomy relevant for the planning of the surgery could be documented. Surgical modifications of the treated nose postoperatively, that is, osteotomies, inserted spreader grafts, diced cartilage in fascia, and tip sutures could be visualized and followed. Ultrasonography of the nose with a high-frequency transducer may be a helpful tool during preoperative planning and postoperative follow-up in septorhinoplasty patients and might be a reasonable completion to the common photographic and functional diagnostic.

  7. Antimicrobial activity of moringa on ear, nose and throat associated ...

    African Journals Online (AJOL)

    This study was aimed at evaluating the antimicrobial activity of Moringa on ear, nose and throat associated fungi and vancomycin resistant cocci. The plant material was extracted with methanol and petroleum ethe and screened for phytochemical contents. The microbial isolates were obtained from females and males ...

  8. Nose and throat complications associated with passive smoking ...

    African Journals Online (AJOL)

    Objective: To assess associations between nose-throat (NT) diseases and passive smoking prevalence among school children. Methods: A cross-sectional survey was carried out on a randomized multistage sample of 381 school children (50.9% males, aged 9.8 ± 3.5 years) from Kinshasa town. Parents and children were ...

  9. Taenia Solium Sneezed out from Nose by an Asymptomatic Child.

    Science.gov (United States)

    Pant, N D; Sharma, M; Neupane, S

    2016-09-01

    Taenia solium is an intestinal parasite and may be excreted in feces in infected patients but our case is unique, as an asymptomatic child sneezed out the proglottids of the parasite from his nose. After the full course of antihelminthic drug the patient excreted a whole worm in his stool.

  10. The nose in children with unilateral cleft lip and palate

    NARCIS (Netherlands)

    Verwoerd, C. D.; Mladina, R.; Nolst Trenité, G. J.; Pigott, R. W.

    1995-01-01

    Surgeons and orthodontists are still challenged to achieve 'better' noses for children with a unilateral cleft or lip, alveoulus and palate (UCLP). Various aspects are discussed: infant anatomy and later changes, developmental mechanics, cleft syndrome in animals with surgically produced facial

  11. Microbiological Assessment of Bacterial Isolates from Ear, Nose And ...

    African Journals Online (AJOL)

    Samples from patients who reported to in-patient ENT unit of Aminu Kano Teaching Hospital, Kano were isolated for further microbiological assessment. One hundred (100) from both male and female patients comprising 55 ear swabs, 30 and 15 throat and nose swabs respectively were screened between February and ...

  12. The nose in children with unilateral cleft lip and palate

    NARCIS (Netherlands)

    C.D.A. Verwoerd (Carel); R. Mladina (R.); G.J. Nolst-Trenité (Gilbert J.); R.W. Pigott (R.)

    1995-01-01

    textabstractSurgeons and orthodontists are still challenged to achieve ‘better’ noses for children with a unilateral cleft or lip, alveolus and palate (UCLP). Various aspects are discussed: infant anatomy and later changes, developmental mechanics, cleft syndrome in animals with surgically produced

  13. CHRISTMAS 2012: RESEARCH Why Rudolph's nose is red: observational study

    NARCIS (Netherlands)

    Ince, Can; van Kuijen, Anne-Marije; Milstein, Dan M. J.; Yürük, Koray; Folkow, Lars P.; Fokkens, Wytske J.; Blix, Arnoldus S.

    2012-01-01

    Objective To characterise the functional morphology of the nasal microcirculation in humans in comparison with reindeer as a means of testing the hypothesis that the luminous red nose of Rudolph, one of the most well known reindeer pulling Santa Claus's sleigh, is due to the presence of a highly

  14. Production of highly charged ion beams Kr32+, Xe44+, Au54+ with Electron String Ion Source (ESIS) Krion-2 and corresponding basic and applied studies

    Science.gov (United States)

    Donets, D. E.; Donets, E. D.; Donets, E. E.; Salnikov, V. V.; Shutov, V. B.

    2010-09-01

    Electron String Ion Source (ESIS) Krion-2 (JINR, Dubna) was used for basic and applied research in various aspects of multiply charged heavy ions production. Energy recuperation mode in ESIS has been proofed first and used for production of highly charged ions 84Kr28+÷84Kr32+, 124Xe40÷124Xe44 and Au51+÷ Au54+. Krion-2 ESIS was mounted on high voltage (HV) platform of LU-20 Linac and used as an injector of highly charged ions during Nuclotron run N° 41. Krion-2 ESIS has produced 3.0.107 124Xe42+ ions per pulse of 7 μs duration. This ion beam was injected into LU-20 and Nuclotron, accelerated up to energy of 186 GeV and the extracted Xe beam was used for physics experiments. Electron String Ion Source Krion-2 demonstrated the high reliability and stability running during 30 days on HV platform. We believe that it is due to an extremely low electron beam power, provided by using the electron string mode of operation: 50 W pulse power and about 10 W average power. Other possible application of ESIS could be its use in injection complexes of synchrotrons and cyclotrons for cancer therapy. Slow and fast extraction of C4+ and C6+ beams from Krion-2 ESIS were preliminary studied towards ESIS optimization for medical accelerators requirements.

  15. Proposal for an ad hoc computer network in the military electronic systems department at the military academy applying bluetooth technology

    Directory of Open Access Journals (Sweden)

    Miroslav R. Terzić

    2011-01-01

    Full Text Available The historical development of the Bluetooth module is given in the introduction of this paper. The importance of the Bluetooth standard for wireless connection on small distances is shown as well. The organization of the Department of Military Electronic Systems is presented with its area of duties, subordinate sections and deployment. The concept of a local area network for this Department, using Bluetooth technology, includes network topology and working regimes based on the main characteristics and technical specifications for the connection with Bluetooth technology. The Department's disperse computer network is proposed as a scatter net where one piconetwork includes the Head of Department and the Heads of Sections while other piconetworks are formed from the Heads of Sections and their subordinates. The security aspect of the presented network deals with basic computer network attack categories, protection methods and aspects. The paper concludes with some recommendations for the local area network using Bluetooth technology with respect to its economical and security aspects as well as to the managing principles of the Department.

  16. Applying the Seattle Heart Failure Model in the Office Setting in the Era of Electronic Medical Records.

    Science.gov (United States)

    Williams, Brent A; Agarwal, Shikhar

    2018-02-23

    Prediction models such as the Seattle Heart Failure Model (SHFM) can help guide management of heart failure (HF) patients, but the SHFM has not been validated in the office environment. This retrospective cohort study assessed the predictive performance of the SHFM among patients with new or pre-existing HF in the context of an office visit.Methods and Results:SHFM elements were ascertained through electronic medical records at an office visit. The primary outcome was all-cause mortality. A "warranty period" for the baseline SHFM risk estimate was sought by examining predictive performance over time through a series of landmark analyses. Discrimination and calibration were estimated according to the proposed warranty period. Low- and high-risk thresholds were proposed based on the distribution of SHFM estimates. Among 26,851 HF patients, 14,380 (54%) died over a mean 4.7-year follow-up period. The SHFM lost predictive performance over time, with C=0.69 and C<0.65 within 3 and beyond 12 months from baseline respectively. The diminishing predictive value was attributed to modifiable SHFM elements. Discrimination (C=0.66) and calibration for 12-month mortality were acceptable. A low-risk threshold of ∼5% mortality risk within 12 months reflects the 10% of HF patients in the office setting with the lowest risk. The SHFM has utility in the office environment.

  17. Challenges in using electronic health record data for CER: experience of 4 learning organizations and solutions applied.

    Science.gov (United States)

    Bayley, K Bruce; Belnap, Tom; Savitz, Lucy; Masica, Andrew L; Shah, Nilay; Fleming, Neil S

    2013-08-01

    To document the strengths and challenges of using electronic health records (EHRs) for comparative effectiveness research (CER). A replicated case study of comparative effectiveness in hypertension treatment was conducted across 4 health systems, with instructions to extract data and document problems encountered using a specified list of required data elements. Researchers at each health system documented successes and challenges, and suggested solutions for addressing challenges. Data challenges fell into 5 categories: missing data, erroneous data, uninterpretable data, inconsistencies among providers and over time, and data stored in noncoded text notes. Suggested strategies to address these issues include data validation steps, use of surrogate markers, natural language processing, and statistical techniques. A number of EHR issues can hamper the extraction of valid data for cross-health system comparative effectiveness studies. Our case example cautions against a blind reliance on EHR data as a single definitive data source. Nevertheless, EHR data are superior to administrative or claims data alone, and are cheaper and timelier than clinical trials or manual chart reviews. All 4 participating health systems are pursuing pathways to more effectively use EHR data for CER.A partnership between clinicians, researchers, and information technology specialists is encouraged as a way to capitalize on the wealth of information contained in the EHR. Future developments in both technology and care delivery hold promise for improvement in the ability to use EHR data for CER.

  18. Characterization of a nuclear compartment shared by nuclear bodies applying ectopic protein expression and correlative light and electron microscopy

    International Nuclear Information System (INIS)

    Richter, Karsten; Reichenzeller, Michaela; Goerisch, Sabine M.; Schmidt, Ute; Scheuermann, Markus O.; Herrmann, Harald; Lichter, Peter

    2005-01-01

    To investigate the accessibility of interphase nuclei for nuclear body-sized particles, we analyzed in cultured cells from human origin by correlative fluorescence and electron microscopy (EM) the bundle-formation of Xenopus-vimentin targeted to the nucleus via a nuclear localization signal (NLS). Moreover, we investigated the spatial relationship of speckles, Cajal bodies, and crystalline particles formed by Mx1 fused to yellow fluorescent protein (YFP), with respect to these bundle arrays. At 37 deg C, the nucleus-targeted, temperature-sensitive Xenopus vimentin was deposited in focal accumulations. Upon shift to 28 deg C, polymerization was induced and filament arrays became visible. Within 2 h after temperature shift, arrays were found to be composed of filaments loosely embedded in the nucleoplasm. The filaments were restricted to limited areas of the nucleus between focal accumulations. Upon incubation at 28 deg C for several hours, NLS vimentin filaments formed bundles looping throughout the nuclei. Speckles and Cajal bodies frequently localized in direct neighborhood to vimentin bundles. Similarly, small crystalline particles formed by YFP-tagged Mx1 also located next to vimentin bundles. Taking into account that nuclear targeted vimentin locates in the interchromosomal domain (ICD), we conclude that nuclear body-sized particles share a common nuclear space which is controlled by higher order chromatin organization

  19. Directionality of nose-emitted echolocation calls from bats without a nose leaf (Plecotus auritus).

    Science.gov (United States)

    Jakobsen, Lasse; Hallam, John; Moss, Cynthia F; Hedenström, Anders

    2018-02-13

    All echolocating bats and whales measured to date emit a directional bio-sonar beam that affords them a number of advantages over an omni-directional beam, i.e. reduced clutter, increased source level and inherent directional information. In this study, we investigated the importance of directional sound emission for navigation through echolocation by measuring the sonar beam of brown long-eared bats, Plecotus auritus Plecotus auritus emits sound through the nostrils but has no external appendages to readily facilitate a directional sound emission as found in most nose emitters. The study shows that P. auritus , despite lacking an external focusing apparatus, emits a directional echolocation beam (directivity index=13 dB) and that the beam is more directional vertically (-6 dB angle at 22 deg) than horizontally (-6 dB angle at 35 deg). Using a simple numerical model, we found that the recorded emission pattern is achievable if P. auritus emits sound through the nostrils as well as the mouth. The study thus supports the hypothesis that a directional echolocation beam is important for perception through echolocation and we propose that animals with similarly non-directional emitter characteristics may facilitate a directional sound emission by emitting sound through both the nostrils and the mouth. © 2018. Published by The Company of Biologists Ltd.

  20. A Discussion on Uncertainty Representation and Interpretation in Model-Based Prognostics Algorithms based on Kalman Filter Estimation Applied to Prognostics of Electronics Components

    Science.gov (United States)

    Celaya, Jose R.; Saxen, Abhinav; Goebel, Kai

    2012-01-01

    This article discusses several aspects of uncertainty representation and management for model-based prognostics methodologies based on our experience with Kalman Filters when applied to prognostics for electronics components. In particular, it explores the implications of modeling remaining useful life prediction as a stochastic process and how it relates to uncertainty representation, management, and the role of prognostics in decision-making. A distinction between the interpretations of estimated remaining useful life probability density function and the true remaining useful life probability density function is explained and a cautionary argument is provided against mixing interpretations for the two while considering prognostics in making critical decisions.

  1. Electron-beam-induced current measurements with applied bias provide insight to locally resolved acceptor concentrations at p-n junctions

    Directory of Open Access Journals (Sweden)

    D. Abou-Ras

    2015-07-01

    Full Text Available Electron-beam-induced current (EBIC measurements have been employed for the investigation of the local electrical properties existing at various types of electrical junctions during the past decades. In the standard configuration, the device under investigation is analyzed under short-circuit conditions. Further insight into the function of the electrical junction can be obtained when applying a bias voltage. The present work gives insight into how EBIC measurements at applied bias can be conducted at the submicrometer level, at the example of CuInSe2 solar cells. From the EBIC profiles acquired across ZnO/CdS/CuInSe2/Mo stacks exhibiting p-n junctions with different net doping densities in the CuInSe2 layers, values for the width of the space-charge region, w, were extracted. For all net doping densities, these values decreased with increasing applied voltage. Assuming a linear relationship between w2 and the applied voltage, the resulting net doping densities agreed well with the ones obtained by means of capacitance-voltage measurements.

  2. Classification of Multiple Chinese Liquors by Means of a QCM-based E-Nose and MDS-SVM Classifier.

    Science.gov (United States)

    Li, Qiang; Gu, Yu; Jia, Jing

    2017-01-30

    Chinese liquors are internationally well-known fermentative alcoholic beverages. They have unique flavors attributable to the use of various bacteria and fungi, raw materials, and production processes. Developing a novel, rapid, and reliable method to identify multiple Chinese liquors is of positive significance. This paper presents a pattern recognition system for classifying ten brands of Chinese liquors based on multidimensional scaling (MDS) and support vector machine (SVM) algorithms in a quartz crystal microbalance (QCM)-based electronic nose (e-nose) we designed. We evaluated the comprehensive performance of the MDS-SVM classifier that predicted all ten brands of Chinese liquors individually. The prediction accuracy (98.3%) showed superior performance of the MDS-SVM classifier over the back-propagation artificial neural network (BP-ANN) classifier (93.3%) and moving average-linear discriminant analysis (MA-LDA) classifier (87.6%). The MDS-SVM classifier has reasonable reliability, good fitting and prediction (generalization) performance in classification of the Chinese liquors. Taking both application of the e-nose and validation of the MDS-SVM classifier into account, we have thus created a useful method for the classification of multiple Chinese liquors.

  3. Classification of Multiple Chinese Liquors by Means of a QCM-based E-Nose and MDS-SVM Classifier

    Directory of Open Access Journals (Sweden)

    Qiang Li

    2017-01-01

    Full Text Available Chinese liquors are internationally well-known fermentative alcoholic beverages. They have unique flavors attributable to the use of various bacteria and fungi, raw materials, and production processes. Developing a novel, rapid, and reliable method to identify multiple Chinese liquors is of positive significance. This paper presents a pattern recognition system for classifying ten brands of Chinese liquors based on multidimensional scaling (MDS and support vector machine (SVM algorithms in a quartz crystal microbalance (QCM-based electronic nose (e-nose we designed. We evaluated the comprehensive performance of the MDS-SVM classifier that predicted all ten brands of Chinese liquors individually. The prediction accuracy (98.3% showed superior performance of the MDS-SVM classifier over the back-propagation artificial neural network (BP-ANN classifier (93.3% and moving average-linear discriminant analysis (MA-LDA classifier (87.6%. The MDS-SVM classifier has reasonable reliability, good fitting and prediction (generalization performance in classification of the Chinese liquors. Taking both application of the e-nose and validation of the MDS-SVM classifier into account, we have thus created a useful method for the classification of multiple Chinese liquors.

  4. E-nose, e-tongue and e-eye for edible olive oil characterization and shelf life assessment: A powerful data fusion approach.

    Science.gov (United States)

    Buratti, Susanna; Malegori, Cristina; Benedetti, Simona; Oliveri, Paolo; Giovanelli, Gabriella

    2018-05-15

    The aim of this work was to investigate the applicability of e-senses (electronic nose, electronic tongue and electronic eye) for the characterization of edible olive oils (extra virgin, olive and pomace) and for the assessment of extra virgin olive oil and olive oil quality decay during storage at different temperatures. In order to obtain a complete description of oil samples, physico-chemical analyses on quality and nutritional parameters were also performed. Data were processed by PCA and a targeted data processing flow-sheet has been applied to physico-chemical and e-senses dataset starting from data pre-processing introducing an innovative normalization method, called t0 centering. On e-senses data a powerful mid-level data fusion approach has been employed to extract relevant information from different analytical sources combining their individual contributions. On physico-chemical data, an alternative approach for grouping extra virgin olive oil and olive oil samples on the basis of their freshness was applied and two classes were identified: fresh and oxidized. A k-NN classification rule was developed to test the performance of e-senses to classify samples in the two classes of freshness and the average value of correctly classified samples was 94%. Results demonstrated that the combined application of e-senses and the innovative data processing strategy allows to characterize edible olive oils of different categories on the basis of their sensorial properties and also to follow the evolution during storage of extra-virgin olive oil and olive oil sensorial properties thus assessing the quality decay of oils. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Separation of γ-ray, electron and proton induced air showers applied to diffuse emission studies with H.E.S.S

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Tanya

    2017-01-18

    A fundamental issue in ground-based gamma-ray astronomy is the identification of γ-ray events among the overwhelming background of air showers induced by charged cosmic rays. Reconstruction techniques exist to distinguish most of the background of hadrons but an irreducible background of electrons and gamma-like protons still remain. I present here a new technique making use of high-altitude Cherenkov light emitted by the charged primary particle and air shower development properties. This method provides a way to distinguish between electrons and gamma rays on a statistical basis. In addition to this, the remaining proton background can also be identified. The technique was developed, tested and applied to studies using the High Energy Stereoscopic System (H.E.S.S.) located in Namibia. The analysis method is especially important in the detection of diffuse signals and eliminates the necessity of a background region in the field of view. The technique was applied to three scientific studies. The latitude profile of the Galactic diffuse γ-ray emission was analysed. A width of σ=0.25±0.05 (0.20±0.06 ) for energies of 380 to 900 GeV(1 to 6 TeV) was determined. The cosmic electron spectrum was measured between 0.38 and 14 TeV and a broken power law was fit to the data. The spectrum steepens from Γ=3.08±0.06 to Γ=3.72±0.12 at a break in energy of 1.11±0.04 TeV. In addition, upper limits on the maximum γ-ray contamination from the Isotropic γ-Ray Background was placed at 4 x 10{sup -3}(5 x 10{sup -3}) MeVcm{sup -2}s{sup -1}sr{sup -1} for energies of 1 to 6 TeV(380 to 900 GeV).

  6. Nose Structure Delineation of Bouguer Anomaly as the Interpretation Basis of Probable Hydrocarbon Traps: A Case Study on the Mainland Area of Northwest Java Basin

    Directory of Open Access Journals (Sweden)

    Kamtono Kamtono

    2014-06-01

    Full Text Available DOI: 10.17014/ijog.v7i3.144Two important aspects in the exploration of oil and gas are technology and exploration concepts, but the use of technology is not always suitable for areas with geological conditions covered by young volcanic sediments or limestone. The land of the Northwest Java Basin is mostly covered by young volcanic products, so exploration using seismic methods will produce less clear image resolution. To identify and interpret the subsurface structure and the possibility of hydrocarbon trap, gravity measurements have been carried out. Delineation of nose structures of a Bouguer anomaly map was used to interpret the probability of hydrocarbon traps. The result of the study shows that the gravity anomalies could be categorized into three groups : low anomaly (< 34 mgal, middle anomaly (34 - 50 mgal, and high anomaly (> 50 mgal. The analysis of Bouguer anomaly indicates that the low anomaly is concentrated in Cibarusa area as a southern part of Ciputat Subbasin, and in Cikampek area. The result of delineation of the Bouguer anomaly map shows the nose structures existing on Cibinong-Cileungsi and Pangkalan-Bekasi Highs, while delineation of residual anomaly map shows the nose structures occurs on Cilamaya-Karawang high. Locally, the gas fields of Jatirangon and Cicauh areas exist on the flank of the nose structure of Pangkalan-Bekasi High, while the oil/gas field of Northern Cilamaya is situated on the flank of the nose structure of Cilamaya-Karawang High. The concept of fluid/gas migration concentrated on nose structures which are delineated from gravity data can be applied in the studied area. This concept needs to be tested in other oil and gas field areas.

  7. White-nose syndrome fungus (Geomyces destructans) in bats, Europe.

    Science.gov (United States)

    Wibbelt, Gudrun; Kurth, Andreas; Hellmann, David; Weishaar, Manfred; Barlow, Alex; Veith, Michael; Prüger, Julia; Görföl, Tamás; Grosche, Lena; Bontadina, Fabio; Zöphel, Ulrich; Seidl, Hans Peter; Seidl, Hans Peter; Blehert, David S

    2010-08-01

    White-nose syndrome is an emerging disease in North America that has caused substantial declines in hibernating bats. A recently identified fungus (Geomyces destructans) causes skin lesions that are characteristic of this disease. Typical signs of this infection were not observed in bats in North America before white-nose syndrome was detected. However, unconfirmed reports from Europe indicated white fungal growth on hibernating bats without associated deaths. To investigate these differences, hibernating bats were sampled in Germany, Switzerland, and Hungary to determine whether G. destructans is present in Europe. Microscopic observations, fungal culture, and genetic analyses of 43 samples from 23 bats indicated that 21 bats of 5 species in 3 countries were colonized by G. destructans. We hypothesize that G. destructans is present throughout Europe and that bats in Europe may be more immunologically or behaviorally resistant to G. destructans than their congeners in North America because they potentially coevolved with the fungus.

  8. Electrolyte depletion in white-nose syndrome bats.

    Science.gov (United States)

    Cryan, Paul M; Meteyer, Carol Uphoff; Blehert, David S; Lorch, Jeffrey M; Reeder, DeeAnn M; Turner, Gregory G; Webb, Julie; Behr, Melissa; Verant, Michelle; Russell, Robin E; Castle, Kevin T

    2013-04-01

    The emerging wildlife disease white-nose syndrome is causing widespread mortality in hibernating North American bats. White-nose syndrome occurs when the fungus Geomyces destructans infects the living skin of bats during hibernation, but links between infection and mortality are underexplored. We analyzed blood from hibernating bats and compared blood electrolyte levels to wing damage caused by the fungus. Sodium and chloride tended to decrease as wing damage increased in severity. Depletion of these electrolytes suggests that infected bats may become hypotonically dehydrated during winter. Although bats regularly arouse from hibernation to drink during winter, water available in hibernacula may not contain sufficient electrolytes to offset winter losses caused by disease. Damage to bat wings from G. destructans may cause life-threatening electrolyte imbalances.

  9. Electrolyte depletion in white-nose syndrome bats

    Science.gov (United States)

    Cryan, Paul M.; Meteyer, Carol Uphoff; Blehert, David S.; Lorch, Jeffrey M.; Reeder, DeeAnn M.; Turner, Gregory G.; Webb, Julie; Behr, Melissa; Verant, Michelle L.; Russell, Robin E.; Castle, Kevin T.

    2013-01-01

    The emerging wildlife disease white-nose syndrome is causing widespread mortality in hibernating North American bats. White-nose syndrome occurs when the fungus Geomyces destructans infects the living skin of bats during hibernation, but links between infection and mortality are underexplored. We analyzed blood from hibernating bats and compared blood electrolyte levels to wing damage caused by the fungus. Sodium and chloride tended to decrease as wing damage increased in severity. Depletion of these electrolytes suggests that infected bats may become hypotonically dehydrated during winter. Although bats regularly arouse from hibernation to drink during winter, water available in hibernacula may not contain sufficient electrolytes to offset winter losses caused by disease. Damage to bat wings from G. destructans may cause life-threatening electrolyte imbalances.

  10. White-nose syndrome fungus (Geomyces destructans) in bats, Europe

    Science.gov (United States)

    Wibbelt, G.; Kurth, A.; Hellmann, D.; Weishaar, M.; Barlow, A.; Veith, M.; Pruger, J.; Gorfol, T.; Grosche, T.; Bontadina, F.; Zophel, U.; Seidl, Hans-Peter; Cryan, P.M.; Blehert, D.S.

    2010-01-01

    White-nose syndrome is an emerging disease in North America that has caused substantial declines in hibernating bats. A recently identified fungus (Geomyces destructans) causes skin lesions that are characteristic of this disease. Typical signs of this infection were not observed in bats in North America before white-nose syndrome was detected. However, unconfirmed reports from Europe indicated white fungal growth on hibernating bats without associated deaths. To investigate these differences, hibernating bats were sampled in Germany, Switzerland, and Hungary to determine whether G. destructans is present in Europe. Microscopic observations, fungal culture, and genetic analyses of 43 samples from 23 bats indicated that 21 bats of 5 species in 3 countries were colonized by G. destructans. We hypothesize that G. destructans is present throughout Europe and that bats in Europe may be more immunologically or behaviorally resistant to G. destructans than their congeners in North America because they potentially coevolved with the fungus.

  11. Qualification Approach for the CMC Nose Cap of X-38

    Science.gov (United States)

    Weihs, H.; Gülhan, A.

    2002-01-01

    In October 2001 the flight hardware of the TPS nose assembly of X-38 has been installed at the main structure of the X-38 V201 vehicle at NASA's Johnson Space Center, Houston Texas. X-38 is a test vehicle for the planned Crew Return Vehicle CRV for the International Space Station ISS. Currently the flight of the X-38 is scheduled for 2005. Besides the Body flaps (MAN-T) and the nose skirt system (ASTRIUM, MAN-T) the nose cap system is one of the essential hot structure components that were developed within Germany's national TETRA (Technologies for future space transportation systems) programme. The integration of the hardware was an important milestone for the nose cap development which started approx. 5 years ago. DLR-Stuttgart is responsible for the design and manufacturing of the CMC based nose cap system, which has to withstand the extreme thermal loads during re-entry which will induce a maximum temperature up to 1750 °C on the surface of the cap. Thus, the shell of the cap system is designed and manufactured using DLR's C/C-SiC material which is a special kind of carbon based ceramic matrix composite (CMC) material produced via the in house liquid silicon infiltration process of DLR. This material has demonstrated its good temperature resistance during FOTON and EXPRESS re-entry capsule missions. Besides the design and manufacturing of the nose cap system, the qualification approach was an important effort of the development work. Missing a test facility which is able to simulate all loading conditions from lift off to re-entry and landing, is was necessary to separate the loads and to use different test facilities. Considering the limitations of the facilities, the budget and time constraints, an optimized test philosophy has been established. The goal was to use a full scale qualification unit including all TPS components of the nose area for most of the tests. These were the simulation of ascent loads given by the shuttle requirements and descent loads

  12. A Novel Medical E-Nose Signal Analysis System

    Directory of Open Access Journals (Sweden)

    Lu Kou

    2017-04-01

    Full Text Available It has been proven that certain biomarkers in people’s breath have a relationship with diseases and blood glucose levels (BGLs. As a result, it is possible to detect diseases and predict BGLs by analysis of breath samples captured by e-noses. In this paper, a novel optimized medical e-nose system specified for disease diagnosis and BGL prediction is proposed. A large-scale breath dataset has been collected using the proposed system. Experiments have been organized on the collected dataset and the experimental results have shown that the proposed system can well solve the problems of existing systems. The methods have effectively improved the classification accuracy.

  13. Breaching Pathogeographic Barriers by the Bat White-Nose Fungus.

    Science.gov (United States)

    Rhodes, Johanna; Fisher, Matthew C

    2018-05-22

    Bat white-nose syndrome has become associated with unparalleled mortality in bat species across the United States since 2006. In a recent article, Drees and colleagues (mBio 8:e01941-17, 2017, https://doi.org/10.1128/mBio.01941-17) utilized both whole-genome sequencing and microsatellite data to explore the origin and spread of the causative agent of bat white-nose syndrome, Pseudogymnoascus destructans The research by Drees et al. supports the hypothesis that P. destructans was introduced into North America from Europe, with molecular dating suggesting a divergence from European isolates approximately 100 years ago. The approaches described in this study are an important contribution toward pinpointing the origins of this infection and underscore the need for more rigorous international biosecurity in order to stem the tide of emerging fungal pathogens. Copyright © 2018 Rhodes and Fisher.

  14. Recent developments in smart freezing technology applied to fresh foods.

    Science.gov (United States)

    Xu, Ji-Cheng; Zhang, Min; Mujumdar, Arun S; Adhikari, Benu

    2017-09-02

    Due to the increased awareness of consumers in sensorial and nutritional quality of frozen foods, the freezing technology has to seek new and innovative technologies for better retaining the fresh like quality of foods. In this article, we review the recent developments in smart freezing technology applied to fresh foods. The application of these intelligent technologies and the associated underpinning concepts have greatly improved the quality of frozen foods and the freezing efficiency. These technologies are able to automatically collect the information in-line during freezing and help control the freezing process better. Smart freezing technology includes new and intelligent technologies and concepts applied to the pretreatment of the frozen product, freezing processes, cold chain logistics as well as warehouse management. These technologies enable real-time monitoring of quality during the freezing process and help improve product quality and freezing efficiency. We also provide a brief overview of several sensing technologies used to achieve automatic control of individual steps of freezing process. These sensing technologies include computer vision, electronic nose, electronic tongue, digital simulation, confocal laser, near infrared spectroscopy, nuclear magnetic resonance technology and ultrasound. Understanding of the mechanism of these new technologies will be helpful for applying them to improve the quality of frozen foods.

  15. Effect of applied hydrostatic pressure on the quenching kinetics, and electronic and molecular structure of eight and nine-coordinate lanthanide complexes in solution

    International Nuclear Information System (INIS)

    Maupin, C.L.; Riehl, J.P.

    1998-01-01

    Full text: Applied hydrostatic pressure may be used as a probe of the reaction mechanism for various solution reactions involving lanthanide ions. In this work we report on the use of high pressure to probe the mechanism of enantioselective quenching between racemic luminescent lanthanide complexes containing Dy(III) Tb(III) and Eu(III), and optically active transition metal complexes as quenchers. Diastereomeric rate constants are obtained from a biexponential fit of the luminescence decay. Particular attention will be given to solvation effects on the measured diastereomeric rate constants. The source of chirality is ascribed to a enantioselective rearrangement step within a bimolecular 'encounter' complex yielding a intermolecular geometry in which the energy transfer is efficient. The effect of high pressure on the molecular and electronic structure of these complexes will also be discussed

  16. Impact of metal ions in porphyrin-based applied materials for visible-light photocatalysis: Key information from ultrafast electronic spectroscopy

    KAUST Repository

    Kar, Prasenjit; Sardar, Samim; Alarousu, Erkki; Sun, Jingya; Seddigi, Zaki Shakir Abdullah; Ahmed, Saleh Abdel Mgeed; Danish, Ekram Yousif; Mohammed, Omar F.; Pal, Samir Kumar

    2014-01-01

    ProtoporphyrinIX-zinc oxide (PP-ZnO) nanohybrids have been synthesized for applications in photocatalytic devices. High-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and steady-state infrared, absorption, and emission spectroscopies have been used to analyze the structural details and optical properties of these nanohybrids. Time-resolved fluorescence and transient absorption techniques have been applied to study the ultrafast dynamic events that are key to photocatalytic activities. The photocatalytic efficiency under visible-light irradiation in the presence of naturally abundant iron(III) and copper(II) ions has been found to be significantly retarded in the former case, but enhanced in the latter case. More importantly, femtosecond (fs) transient absorption data have clearly demonstrated that the residence of photoexcited electrons from the sensitizer PP in the centrally located iron moiety hinders ground-state bleach recovery of the sensitizer, affecting the overall photocatalytic rate of the nanohybrid. The presence of copper(II) ions, on the other hand, offers additional stability against photobleaching and eventually enhances the efficiency of photocatalysis. In addition, we have also explored the role of UV light in the efficiency of photocatalysis and have rationalized our observations from femtosecond- to picosecond-resolved studies. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Impact of metal ions in porphyrin-based applied materials for visible-light photocatalysis: Key information from ultrafast electronic spectroscopy

    KAUST Repository

    Kar, Prasenjit

    2014-07-10

    ProtoporphyrinIX-zinc oxide (PP-ZnO) nanohybrids have been synthesized for applications in photocatalytic devices. High-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and steady-state infrared, absorption, and emission spectroscopies have been used to analyze the structural details and optical properties of these nanohybrids. Time-resolved fluorescence and transient absorption techniques have been applied to study the ultrafast dynamic events that are key to photocatalytic activities. The photocatalytic efficiency under visible-light irradiation in the presence of naturally abundant iron(III) and copper(II) ions has been found to be significantly retarded in the former case, but enhanced in the latter case. More importantly, femtosecond (fs) transient absorption data have clearly demonstrated that the residence of photoexcited electrons from the sensitizer PP in the centrally located iron moiety hinders ground-state bleach recovery of the sensitizer, affecting the overall photocatalytic rate of the nanohybrid. The presence of copper(II) ions, on the other hand, offers additional stability against photobleaching and eventually enhances the efficiency of photocatalysis. In addition, we have also explored the role of UV light in the efficiency of photocatalysis and have rationalized our observations from femtosecond- to picosecond-resolved studies. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Characterization of volatile profile from ten different varieties of Chinese jujubes by HS-SPME/GC-MS coupled with E-nose.

    Science.gov (United States)

    Chen, Qinqin; Song, Jianxin; Bi, Jinfeng; Meng, Xianjun; Wu, Xinye

    2018-03-01

    Volatile profile of ten different varieties of fresh jujubes was characterized by HS-SPME/GC-MS (headspace solid phase micro-extraction combined with gas chromatography-mass spectrometry) and E-nose (electronic nose). GC-MS results showed that a total of 51 aroma compounds were identified in jujubes, hexanoic acid, hexanal, (E)-2-hexenal, (Z)-2-heptenal, benzaldehyde and (E)-2-nonenal were the main aroma components with contributions that over 70%. Differentiation of jujube varieties was conducted by cluster analysis of GC-MS data and principal component analysis & linear discriminant analysis of E-nose data. Both results showed that jujubes could be mainly divided into two groups: group A (JZ, PDDZ, JSXZ and LWZZ) and group B (BZ, YZ, MZ, XZ and DZ). There were significant differences in contents of alcohols, acids and aromatic compounds between group A and B. GC-MS coupled with E-nose could be a fast and accurate method to identify the general flavor difference in different varieties of jujubes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Strain Behavior of Concrete Panels Subjected to Different Nose Shapes of Projectile Impact.

    Science.gov (United States)

    Lee, Sangkyu; Kim, Gyuyong; Kim, Hongseop; Son, Minjae; Choe, Gyeongcheol; Nam, Jeongsoo

    2018-03-09

    This study evaluates the fracture properties and rear-face strain distribution of nonreinforced and hooked steel fiber-reinforced concrete panels penetrated by projectiles of three different nose shapes: sharp, hemispherical, and flat. The sharp projectile nose resulted in a deeper penetration because of the concentration of the impact force. Conversely, the flat projectile nose resulted in shallower penetrations. The penetration based on different projectile nose shapes is directly related to the impact force transmitted to the rear face. Scabbing can be more accurately predicted by the tensile strain on the rear face of concrete due to the projectile nose shape. The tensile strain on the rear face of the concrete was reduced by the hooked steel fiber reinforcement because the hooked steel fiber absorbed some of the impact stress transmitted to the rear face of the concrete. Consequently, the strain behavior on the rear face of concrete according to the projectile nose shape was confirmed.

  20. Strain Behavior of Concrete Panels Subjected to Different Nose Shapes of Projectile Impact

    Directory of Open Access Journals (Sweden)

    Sangkyu Lee

    2018-03-01

    Full Text Available This study evaluates the fracture properties and rear-face strain distribution of nonreinforced and hooked steel fiber-reinforced concrete panels penetrated by projectiles of three different nose shapes: sharp, hemispherical, and flat. The sharp projectile nose resulted in a deeper penetration because of the concentration of the impact force. Conversely, the flat projectile nose resulted in shallower penetrations. The penetration based on different projectile nose shapes is directly related to the impact force transmitted to the rear face. Scabbing can be more accurately predicted by the tensile strain on the rear face of concrete due to the projectile nose shape. The tensile strain on the rear face of the concrete was reduced by the hooked steel fiber reinforcement because the hooked steel fiber absorbed some of the impact stress transmitted to the rear face of the concrete. Consequently, the strain behavior on the rear face of concrete according to the projectile nose shape was confirmed.

  1. Načrtovani preventivni hišni obisk pri nosečnici

    OpenAIRE

    Hofinger Mihelič, Špela

    2009-01-01

    Rojstvo zdravega otroka je nedvomno eden izmed najpomembnejših dogodkov v življenju posameznika in družine. Namen diplomske naloge je bil ugotoviti v kolikšni meri se pri nosečnicah vključuje v preventivo patronažna medicinska sestra (PMS) in kaj nosečnice pričakujejo od njenega hišnega obiska. Cilj je bil oceniti želje nosečnic po hišnem obisku PMS in ugotoviti kje dobijo nosečnice največ informacij o nosečnosti in zdravem načinu življenja ter ugotoviti koliko so nosečnice poučene o pravicah...

  2. Optical excitation and electron relaxation dynamics at semiconductor surfaces: a combined approach of density functional and density matrix theory applied to the silicon (001) surface

    Energy Technology Data Exchange (ETDEWEB)

    Buecking, N

    2007-11-05

    In this work a new theoretical formalism is introduced in order to simulate the phononinduced relaxation of a non-equilibrium distribution to equilibrium at a semiconductor surface numerically. The non-equilibrium distribution is effected by an optical excitation. The approach in this thesis is to link two conventional, but approved methods to a new, more global description: while semiconductor surfaces can be investigated accurately by density-functional theory, the dynamical processes in semiconductor heterostructures are successfully described by density matrix theory. In this work, the parameters for density-matrix theory are determined from the results of density-functional calculations. This work is organized in two parts. In Part I, the general fundamentals of the theory are elaborated, covering the fundamentals of canonical quantizations as well as the theory of density-functional and density-matrix theory in 2{sup nd} order Born approximation. While the formalism of density functional theory for structure investigation has been established for a long time and many different codes exist, the requirements for density matrix formalism concerning the geometry and the number of implemented bands exceed the usual possibilities of the existing code in this field. A special attention is therefore attributed to the development of extensions to existing formulations of this theory, where geometrical and fundamental symmetries of the structure and the equations are used. In Part II, the newly developed formalism is applied to a silicon (001)surface in a 2 x 1 reconstruction. As first step, density-functional calculations using the LDA functional are completed, from which the Kohn-Sham-wave functions and eigenvalues are used to calculate interaction matrix elements for the electron-phonon-coupling an the optical excitation. These matrix elements are determined for the optical transitions from valence to conduction bands and for electron-phonon processes inside the

  3. On the impact of a concave nosed axisymmetric body on a free surface

    OpenAIRE

    Mathai, Varghese; Govardhan, Raghuraman N.; Arakeri, Vijay H.

    2017-01-01

    We report on an experimental study of the vertical impact of a concave nosed axisymmetric body on a free surface. Previous studies have shown that bodies with a convex nose, like a sphere, produce a well defined splash with a relatively large cavity behind the model. In contrast, we find that with a concave nose, there is hardly a splash and the cavity extent is greatly reduced. This may be explained by the fact that in the concave nosed case, the initial impact is between a confined air pock...

  4. The use and reliability of SymNose for quantitative measurement of the nose and lip in unilateral cleft lip and palate patients.

    Science.gov (United States)

    Mosmuller, David; Tan, Robin; Mulder, Frans; Bachour, Yara; de Vet, Henrica; Don Griot, Peter

    2016-10-01

    It is essential to have a reliable assessment method in order to compare the results of cleft lip and palate surgery. In this study the computer-based program SymNose, a method for quantitative assessment of the nose and lip, will be assessed on usability and reliability. The symmetry of the nose and lip was measured twice in 50 six-year-old complete and incomplete unilateral cleft lip and palate patients by four observers. For the frontal view the asymmetry level of the nose and upper lip were evaluated and for the basal view the asymmetry level of the nose and nostrils were evaluated. A mean inter-observer reliability when tracing each image once or twice was 0.70 and 0.75, respectively. Tracing the photographs with 2 observers and 4 observers gave a mean inter-observer score of 0.86 and 0.92, respectively. The mean intra-observer reliability varied between 0.80 and 0.84. SymNose is a practical and reliable tool for the retrospective assessment of large caseloads of 2D photographs of cleft patients for research purposes. Moderate to high single inter-observer reliability was found. For future research with SymNose reliable outcomes can be achieved by using the average outcomes of single tracings of two observers. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Similar Fracture Patterns in Human Nose and Gothic Cathedral.

    Science.gov (United States)

    Lee, Shu Jin; Tse, Kwong Ming; Lee, Heow Pueh

    2015-10-01

    This study proposes that the bony anatomy of the human nose and masonry structure of the Gothic cathedral are geometrically similar, and have common fracture patterns. We also aim to correlate the fracture patterns observed in patients' midface structures with those seen in the Gothic cathedral using computational approach. CT scans of 33 patients with facial fractures were examined and compared with computer simulations of both the Gothic cathedral and human nose. Three similar patterns were found: (1) Cracks of the nasal arch with crumpling of the vertical buttresses akin to the damage seen during minor earthquakes; (2) lateral deviation of the central nasal arch and collapse of the vertical buttresses akin to those due to lateral forces from wind and in major earthquakes; and (3) Central arch collapse seen as a result of collapse under excessive dead weight. Interestingly, the finding of occult nasal and septal fractures in the mandible fractures with absence of direct nasal trauma highlights the possibility of transmission of forces from the foundation to the arch leading to structural failure. It was also found that the structural buttresses of the Gothic cathedral delineate the vertical buttresses in the human midface structure. These morphologic similarities between the human nose and Gothic cathedral will serve as a basis to study the biomechanics of nasal fractures. Identification of structural buttresses in a skeletal structure has important implications for reconstruction as reestablishment of structural continuity restores normal anatomy and architectural stability of the human midface structure. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Nasal valve evaluation in the Mexican-Hispanic (mestizo) nose.

    Science.gov (United States)

    Jasso-Ramírez, Elizabeth; Sánchez Y Béjar, Fernando; Arcaute Aizpuru, Fernando; Maulen Radován, Irene E; de la Garza Hesles, Héctor

    2018-04-01

    Our aim in this study was to determine the angle of the internal nasal valve in Mexican patients with the "mestizo nose" feature and without nasal obstructive symptoms. The work was prospective, comparative, and observational in nature and included patients >14 years of age who were seen in the Otolaryngology Department at the Los Angeles Lomas Hospital between April and May 2016. The angle of the internal nasal valve was measured in 30 patients without obstructive symptoms. Endoscopic examination was performed with a 0° endoscope framed with tape at a 13-mm distance from the endoscope's tip, and digital photographs of the internal nasal valve were taken. The measurement of the angle of the internal nasal valve was made in sexagesimal degrees using Golden Ratio v3.1 (2012) software. Statistical analysis was performed using Excel v15.13.3. The angles of the internal nasal valve of the patients were (mean ± standard deviation) 24.07 ± 4.8° for the right nasal cavity and 25.07 ± 5.0° for the left nasal cavity, wider than the angle reported in the normal Caucasian nose established in the literature. According to our results, the Mexican-Hispanic mestizo nose has a wider angle in the internal nasal valve than that considered normal in the literature (10°-15°). We believe it is necessary to undertake a second study and add an airflow resistance measurement with a rhinomanometry procedure so we can compare the results with those in the Caucasian population. © 2018 ARS-AAOA, LLC.

  7. Hızma Induced Papul of Nose Mimicking Pyogenic Granuloma

    Directory of Open Access Journals (Sweden)

    Mualla Polat

    2014-09-01

    Full Text Available The application of body piercing is popular among young people, who consider it as a sign of marginality, beauty, or group identity. Piercing procedure is observed to cause a large number of complications such as infections, pain, inflammatory reactions, bleeding, dental fractures or fissures, and gingival damage, etc., mostly in young individuals. Hizma is a traditional body ornament worn by Anatolian women via a piercing procedure. Herein, we describe a papule of nose mimicking pyogenic granuloma as an uncommon complication of Hızma.

  8. Bat white-nose syndrome: An emerging fungal pathogen?

    Science.gov (United States)

    Blehert, D.S.; Hicks, A.C.; Behr, M.; Meteyer, C.U.; Berlowski-Zier, B. M.; Buckles, E.L.; Coleman, J.T.H.; Darling, S.R.; Gargas, A.; Niver, R.; Okoniewski, J.C.; Rudd, R.J.; Stone, W.B.

    2009-01-01

    White-nose syndrome (WNS) is a condition associated with an unprecedented bat mortality event in the northeastern United States. Since the winter of 2006*2007, bat declines exceeding 75% have been observed at surveyed hibernacula. Affected bats often present with visually striking white fungal growth on their muzzles, ears, and/or wing membranes. Direct microscopy and culture analyses demonstrated that the skin of WNS-affected bats is colonized by a psychro-philic fungus that is phylogenetically related to Geomyces spp. but with a conidial morphology distinct from characterized members of this genus. This report characterizes the cutaneous fungal infection associated with WNS.

  9. Ear, nose, and throat disorders in a nigerian rural community

    Directory of Open Access Journals (Sweden)

    Waheed Atilade Adegbiji

    2017-01-01

    Full Text Available Aims and Objectives: This study aimed at assessing the prevalence of ear, nose, and throat with head and neck diseases in a rural community in Oyo State, Nigeria. Materials and Methods: This is a prospective community-based study of ear, nose, and throat diseases. The study was carried out over a period of 3 months (January to March 2017. Verbal consent was obtained from the village head and participants. A total of 738 individuals were enrolled into the study. Interview-assisted questionnaire was administered to obtain bio data and otorhinolaryngological history from all participants, followed by examination and investigation. Data obtained were collated and statistically analyzed using SPSS version 16. Results: A total of 738 consented participants had various forms of ear, nose, and throat disorders. They constituted 435 (58.9% males and 303 (41.1% females, with a male: female ratio of 1:1. Majority of enrollee were dependent age groups. These age groups were 27.4% (1–10, 25.5% (11–20, and 14.1% (51–60. The occupational status revealed that 28.9% were employed; 9.3% were retired; 45.5% were children/students/apprenticeship; and 16.3% were artisans, homemakers, and farmers. Nasal diseases (34.4% were the most common otorhinolaryngological, head and neck disorders while ear, nose, and throat with head and neck diseases were responsible for 43.4%, 14.6%, and 7.6%, respectively. The common diseases were wax impaction (11.7%, sinusitis (14.4%, and allergic rhinitis (22.6%. Less prevalent otorhinolaryngological, head and neck diseases were vertigo/balance disorder (0.9%, cervical spondylosis (1.6%, and pharyngitis/tonsillitis (2.0%. Common procedures performed included impacted earwax removal (22.8%, aural toilet/dressing (14.4%, pure tone audiometry (32.5%, tympanometry (18.4%, endoscopy (9.8%, and antral irrigation (5.7%. Referred cases of 7.2% were recorded. The barriers experienced by these villagers in seeking otorhinolaryngological

  10. Effect of nose bluntness on boundary layer stability and transition

    Science.gov (United States)

    Malik, M. R.; Spall, R. E.; Chang, C.-L.

    1990-01-01

    The effect of nose bluntness on boundary layer instability is studied theoretically for a Mach 8 flow past a 7 degree semivertex cone. The basic flow is computed by solving the parabolized Navier-Stokes equations. Linear stability analysis of the basic flow reveals that, with small amount of bluntness, the critical Reynolds number for the onset of instability increases by an order of magnitude compared to the sharp cone value. The computed second mode frequencies are also in reasonable agreement with the experimental results. The results are used to explain the effect of unit Reynolds number on transition present in the quiet aeroballistic range data.

  11. Endoscopic surgery of the nose and paranasal sinus.

    Science.gov (United States)

    Palmer, Orville; Moche, Jason A; Matthews, Stanley

    2012-05-01

    Mucosal preservation is of paramount importance in the diagnosis and surgical management of the sinonasal tract. The endoscope revolutionized the practice of endoscopic nasal surgery. As a result, external sinus surgery is performed less frequently today, and more emphasis is placed on functional endoscopy and preservation of normal anatomy. Endoscopic surgery of the nose and paranasal sinus has provided improved surgical outcomes and has shortened the length of stay in hospital. It has also become a valuable teaching tool. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Qualitative and quantitative analysis on aroma characteristics of ginseng at different ages using E-nose and GC-MS combined with chemometrics.

    Science.gov (United States)

    Cui, Shaoqing; Wang, Jun; Yang, Liangcheng; Wu, Jianfeng; Wang, Xinlei

    2015-01-01

    Aroma profiles of ginseng samples at different ages were investigated using electronic nose (E-nose) and GC-MS techniques combined with chemometrics analysis. The bioactive ginsenoside and volatile oil content increased with age. E-nose performed well in the qualitative analyses. Both Principal Component Analysis (PCA) and Discriminant Functions Analysis (DFA) performed well when used to analyze ginseng samples, with the first two principal components (PCs) explaining 85.51% and the first two factors explaining 95.51% of the variations. Hierarchical Cluster Analysis (HCA) successfully clustered the different types of ginsengs into four groups. A total of 91 volatile constituents were identified. 50 of them were calculated and compared using GC-MS. The main fragrance ingredients were terpenes and alcohols, followed by aromatics and ester. The changes in terpenes, alcohols, aromatics, esters, and acids during the growth year once again confirmed the dominant role of terpenes. The Partial Least Squares (PLS) loading plot of gas sensors and aroma ingredients indicated that particular sensors were closely related to terpenes. The scores plot indicated that terpenes and its corresponding sensors contributed the most in grouping. As regards to quantitative analyze, 7 constituent of terpenes could be accurately explained and predicted by using gas sensors in PLS models. In predicting ginseng age using Back Propagation-Artificial Neural Networks (BP-ANN), E-nose data was found to predict more accurately than GC-MS data. E-nose measurement may be a potential method for determining ginseng age. The combination of GC-MS can help explain the hidden correlation between sensors and fragrance ingredients from two different viewpoints. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Classification of E-Nose Aroma Data of Four Fruit Types by ABC-Based Neural Network

    Directory of Open Access Journals (Sweden)

    M. Fatih Adak

    2016-02-01

    Full Text Available Electronic nose technology is used in many areas, and frequently in the beverage industry for classification and quality-control purposes. In this study, four different aroma data (strawberry, lemon, cherry, and melon were obtained using a MOSES II electronic nose for the purpose of fruit classification. To improve the performance of the classification, the training phase of the neural network with two hidden layers was optimized using artificial bee colony algorithm (ABC, which is known to be successful in exploration. Test data were given to two different neural networks, each of which were trained separately with backpropagation (BP and ABC, and average test performances were measured as 60% for the artificial neural network trained with BP and 76.39% for the artificial neural network trained with ABC. Training and test phases were repeated 30 times to obtain these average performance measurements. This level of performance shows that the artificial neural network trained with ABC is successful in classifying aroma data.

  14. Datasheet: Pseudogymnoascus destructans (white-nose syndrome fungus)

    Science.gov (United States)

    Blehert, David; Lankau, Emily W.

    2017-01-01

    Pseudogymnoascus destructans is a psychrophilic (cold-loving) fungus that causes white-nose syndrome (WNS), an emerging disease of North American bats that has caused unprecedented population declines. The fungus is believed to have been introduced to North America from Europe or Asia (where it is present but does not cause significant mortality), but the full extent of its native range is unknown. The route of introduction is also unknown. In North America, hibernating bats become infected with P. destructans when body temperature decreases during winter torpor into the range permissive for growth of this fungus. Infected bats may develop visible fungal growth on the nose or wings, awaken more frequently from torpor, and experience a cascade of physiologic changes that result in weight loss, dehydration, electrolyte imbalances, and death. P. destructans persists in the environments of underground bat hibernation sites (hibernacula) and is believed to spread primarily by natural movements of infected bats. The first evidence of WNS in North America is from a photograph of a hibernating bat taken during winter of 2005-2006 in a hibernaculum near Albany, New York. P. destructans subsequently spread rapidly from the northeastern United States throughout much of the eastern portions of the United States and Canada, and most recently (as of May 2017) was detected in Washington State. It has killed millions of bats, threatening some species with regional extirpation and putting at risk the valuable environmental services that bats provide by eating harmful insects.

  15. Diseases of the nose and paranasal sinuses in child.

    Science.gov (United States)

    Stenner, Markus; Rudack, Claudia

    2014-01-01

    Diseases of the pediatric nose and nasal sinuses as well as neighboring anatomical structures encompass a variety of pathologies, especially of inflammatory nature. Congenital disease, such as malformations and structural deviations of the nasal septum, as well as systemic metabolic pathologies affecting the nose and sinuses, rarely require medical therapy from an Otolaryngologist. The immunological function of the mucosa and genetic factors play a role in the development of disease in the pediatric upper airway tract, especially due to the constantly changing anatomy in this growth phase. Disease description of the nose and nasal sinuses due to mid-facial growth must also take developmental age differences (infant, toddler, preschool, and school age) into account. Epidemiological examinations and evidence based studies are often lacking in the pediatric population. The wide range of inflammatory diseases of the nose and paranasal sinuses, such as the acute and chronic rhinosinusitis, the allergic rhinitis, and adenoid disease, play a role in the susceptibility of a child to infection. The susceptibility to infection depends on the pediatric age structure (infant, young child) and has yet to be well defined. The acute rhinosinusitis in children develops after a viral infection of the upper airways, also referred to as the "common cold" in the literature. It usually spontaneously heals within ten days without any medical therapy. Antibiotic therapy is prudent in complicated episodes of ARS. The antibiotic therapy is reserved for children with complications or associated disease, such as bronchial asthma and/or chronic bronchitis. A chronic rhinosinusitis is defined as the inflammatory change in the nasal mucosa and nasal sinus mucosa, in which the corresponding symptoms persist for over 12 weeks. The indication for CT-imaging of the nasal sinuses is reserved for cases of chronic rhinosinusitis that have been successfully treated with medication. A staged therapeutic

  16. The pig's nose and its role in dominance relationships and harmful behaviour

    NARCIS (Netherlands)

    Camerlink, I.; Turner, S.P.

    2013-01-01

    Affiliative behaviour may have an essential role in many behavioural processes. Gently nosing between group members occurs in almost all social behavioural processes of pigs (Sus scrofa), but the reasons for its performance are unclear. We examined whether nosing between pigs was related to

  17. Analysis of New Aerodynamic Design of the Nose Cone Section Using CFD and SPH

    Directory of Open Access Journals (Sweden)

    Bogdan-Alexandru BELEGA

    2015-06-01

    Full Text Available A new nose cones concept that promises a gain in performance over existing conventional nose cones is discussed in this paper. It is shown that significant performance gains result from the adaptation of the exhaust flow to the ambient pressure. For this complex work, it was necessary to collect and study the various nose cone shapes and the equations describing them? The paper objective was to identify the types of nose cones with ejector channels and specific aerodynamic characteristics of different types of nose cones. The scope of this paper is to develop some prototype profiles with outstanding aerodynamic qualities and low cost for use in construction projects for missile increasing their range and effect on target. The motivation for such a work is caused by a lack of data on aerodynamics for profiles of some nose cones and especially improved aerodynamic qualities that can be used in designing missiles/ rockets. This design method consists of a geometry creation step in which a three-dimensional geometry is generated, a mathematical model presented and a simple flow analysis (FLUENT Simulation from SolidWorks2012 and ANSYS Simulation with SPH for fluid-structure interaction, step which predicts the air intake mass flow rate. Flow phenomena observed in numerical simulations during different nose cone operations are highlighted, critical design aspects and operation conditions are discussed, and performance characteristics of the selected nose cone are presented.

  18. After irradiation of the throat or nose area: pay attention to the eye

    International Nuclear Information System (INIS)

    Balen, A.Th.M. van

    1984-01-01

    Radiotherapy of carcinomas in the nose can give delayed side effects on the visual system. In this article four cases are described, in which a neuropathy of the optical nerve, caused by vascular damaging, developed one to three years after radiotherapy of nose-neoplasms, with total irradiation doses of 7000 rad. (Auth.)

  19. A Combined CFD/Characteristic Method for Prediction and Design of Hypersonic Inlet with Nose Bluntness

    Science.gov (United States)

    Gao, Wenzhi; Li, Zhufei; Yang, Jiming

    Leading edge bluntness is widely used in hypersonic inlet design for thermal protection[1]. Detailed research of leading edge bluntness on hypersonic inlet has been concentrated on shock shape correlation[2], boundary layer flow[3], inlet performance[4], etc. It is well known that blunted noses cause detached bow shocks which generate subsonic regions around the noses and entropy layers in the flowfield.

  20. On the impact of a concave nosed axisymmetric body on a free surface

    NARCIS (Netherlands)

    Mathai, Varghese; Govardhan, R.N.; Arakeri, V.H.

    2015-01-01

    We report on an experimental study of the vertical impact of a concave nosed axisymmetric body on a free surface. Previous studies have shown that bodies with a convex nose, like a sphere, produce a well defined splash with a relatively large cavity behind the model. In contrast, we find that with a

  1. An audit of Ear, Nose and Throat diseases in a tertiary health ...

    African Journals Online (AJOL)

    Conclusion: This study showed that otitis media, obstructive adenoid, foreign bodies in the ear and throat infections were the common ear, nose, throat disorders seen in patients aged ≤15years whereas, hearing loss, rhinosinusitis and tumors were the common disorders of ear, nose and throat seen in patients aged 16 ...

  2. 21 CFR 874.3620 - Ear, nose, and throat synthetic polymer material.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat synthetic polymer material. 874.3620 Section 874.3620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN..., and throat synthetic polymer material. (a) Identification. Ear, nose, and throat synthetic polymer...

  3. An analytical model for force prediction in ball nose micro milling of inclined surfaces

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2010-01-01

    Ball nose micro milling is a key process for the generation of free form surfaces and inclined surfaces often present in mould inserts for micro replication. This paper presents a new cutting force model for ball nose micro milling that is capable of taking into account the effect of the edge...

  4. Aging time and brand determination of pasteurized milk using a multisensor e-nose combined with a voltammetric e-tongue

    International Nuclear Information System (INIS)

    Bougrini, Madiha; Tahri, Khalid; Haddi, Zouhair; El Bari, Nezha; Llobet, Eduard; Jaffrezic-Renault, Nicole; Bouchikhi, Benachir

    2014-01-01

    A combined approach based on a multisensor system to get additional chemical information from liquid samples through the analysis of the solution and its headspace is illustrated and commented. In the present work, innovative analytical techniques, such as a hybrid e-nose and a voltammetric e-tongue were elaborated to differentiate between different pasteurized milk brands and for the exact recognition of their storage days through the data fusion technique of the combined system. The Principal Component Analysis (PCA) has shown an acceptable discrimination of the pasteurized milk brands on the first day of storage, when the two instruments were used independently. Contrariwise, PCA indicated that no clear storage day's discrimination can be drawn when the two instruments are applied separately. Mid-level of abstraction data fusion approach has demonstrated that results obtained by the data fusion approach outperformed the classification results of the e-nose and e-tongue taken individually. Furthermore, the Support Vector Machine (SVM) supervised method was applied to the new subset and confirmed that all storage days were correctly identified. This study can be generalized to several beverage and food products where their quality is based on the perception of odor and flavor. - Highlights: • Five pasteurized milk brands were differentiated using e-nose and e-tongue. • E-tongue allowed a correct distinction of the milk brands comparing to the e-nose. • The combined system allows determining the storage days of pasteurized milk. • No clear storage day’s discrimination can be drawn when applied e-systems separately. • Data fusion method has been successful in the identification of the storage days

  5. Aging time and brand determination of pasteurized milk using a multisensor e-nose combined with a voltammetric e-tongue

    Energy Technology Data Exchange (ETDEWEB)

    Bougrini, Madiha [Sensor Electronic and Instrumentation Group, Moulay Ismaïl University, Faculty of Sciences, Physics Department, B.P. 11201, Zitoune, Meknes (Morocco); Université de Lyon, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR CNRS 5280, 5, rue de la Doua, 69100 Villeurbanne Cedex (France); Tahri, Khalid [Sensor Electronic and Instrumentation Group, Moulay Ismaïl University, Faculty of Sciences, Physics Department, B.P. 11201, Zitoune, Meknes (Morocco); Haddi, Zouhair [Sensor Electronic and Instrumentation Group, Moulay Ismaïl University, Faculty of Sciences, Physics Department, B.P. 11201, Zitoune, Meknes (Morocco); MINOS-EMaS, Electronic Engineering Department, Universitat Rovira i Virgili, Avda. Països Catalans, 26, 43007 Tarragona (Spain); El Bari, Nezha [Biotechnology Agroalimentary and Biomedical Analysis Group, Moulay Ismaïl University, Faculty of Sciences, Biology Department, B.P. 11201, Zitoune, Meknes (Morocco); Llobet, Eduard [MINOS-EMaS, Electronic Engineering Department, Universitat Rovira i Virgili, Avda. Països Catalans, 26, 43007 Tarragona (Spain); Jaffrezic-Renault, Nicole [Université de Lyon, Université Claude Bernard Lyon 1, Institut des Sciences Analytiques, UMR CNRS 5280, 5, rue de la Doua, 69100 Villeurbanne Cedex (France); Bouchikhi, Benachir, E-mail: benachir.bouchikhi@gmail.com [Sensor Electronic and Instrumentation Group, Moulay Ismaïl University, Faculty of Sciences, Physics Department, B.P. 11201, Zitoune, Meknes (Morocco)

    2014-12-01

    A combined approach based on a multisensor system to get additional chemical information from liquid samples through the analysis of the solution and its headspace is illustrated and commented. In the present work, innovative analytical techniques, such as a hybrid e-nose and a voltammetric e-tongue were elaborated to differentiate between different pasteurized milk brands and for the exact recognition of their storage days through the data fusion technique of the combined system. The Principal Component Analysis (PCA) has shown an acceptable discrimination of the pasteurized milk brands on the first day of storage, when the two instruments were used independently. Contrariwise, PCA indicated that no clear storage day's discrimination can be drawn when the two instruments are applied separately. Mid-level of abstraction data fusion approach has demonstrated that results obtained by the data fusion approach outperformed the classification results of the e-nose and e-tongue taken individually. Furthermore, the Support Vector Machine (SVM) supervised method was applied to the new subset and confirmed that all storage days were correctly identified. This study can be generalized to several beverage and food products where their quality is based on the perception of odor and flavor. - Highlights: • Five pasteurized milk brands were differentiated using e-nose and e-tongue. • E-tongue allowed a correct distinction of the milk brands comparing to the e-nose. • The combined system allows determining the storage days of pasteurized milk. • No clear storage day’s discrimination can be drawn when applied e-systems separately. • Data fusion method has been successful in the identification of the storage days.

  6. Sticker electronics

    KAUST Repository

    Hussain, Muhammad Mustafa; Torres Sevilla, Galo Andres; Diaz Cordero, Marlon Steven

    2017-01-01

    Electronic stickers may be manufactured on flexible substrates (110, 120, 130) as layers and packaged together. The package may then have an adhesive applied to one side to provide capability for sticking the electronic devices to surfaces

  7. Sharp Nose Lens Design Using Refractive Index Gradient

    Science.gov (United States)

    1982-06-01

    guided munitions infrared optics gunsunhe ramjet A AT(CaN011m0. = reerfse aide It nRa6"uWF 4191 #ifaU~ IV Week an For infrared sensors located at the...014-6601 uii THIS PAaE(Uha D heem ABSTRACT For infrared sensors located at the nose of a missile or a projectile, an age-olQ problem occurs. A conflict...JalA..... IaW3. *a aaa a w o. a 0 % a * J. 4 a N N.t 6 N6 N16 N6 vN6 36 ,43NNh 3..~. N N."J2SO N N 3j61 ~N N 2N N N.a~w3 W ww2 .~ w2fw W N

  8. An Artificial Nose Based on Microcantilever Array Sensors

    International Nuclear Information System (INIS)

    Lang, H P; Ramseyer, J P; Grange, W; Braun, T; Schmid, D; Hunziker, P; Jung, C; Hegner, M; Gerber, C

    2007-01-01

    We used microfabricated cantilever array sensors for an artificial nose setup. Each cantilever is coated on its top surface with a polymer layer. Volatile gaseous analytes are detected by tracking the diffusion process of the molecules into the polymer layers, resulting in swelling of the polymer layers and therewith bending of the cantilevers. From the bending pattern of all cantilevers in the array, a characteristic 'fingerprint' of the analyte is obtained, which is evaluated using principal component analysis. In a flow of dry nitrogen gas, the bending of the cantilevers is reverted to its initial state before exposure to the analyte, which allows reversible and reproducible operation of the sensor. We show examples of detection of solvents, perfume essences and beverage flavors. In a medical application, the setup provides indication of presence of diseases in patient's breath samples

  9. Nosely III Settlement by Results of Studies in 2008

    Directory of Open Access Journals (Sweden)

    Mikheev Alexey V.

    2016-03-01

    Full Text Available The article peresents results of new archaeological studies of the medieval horizon of Nosely III settlement in Mari Volga region. It contains defi nitions of objects connected with the medieval layer (household pits. The authors provide results of analysis of the ceramic material represented by the local (hand-made, early wheel and “Slavicoid” ceramics and imported (wheel-made Russian and Bulgar-Horde ware and complex of items. New materials allow us to provide a more precise dating of the settlement and limit the time of its existence to 14th – 15th centuries and defi ne it as a Mari rural settlement belonging to the district of the Maly Sundyr (Vazhnanger hillfort.

  10. Filtration of droplets in the nose of the rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Davies, C N

    1946-01-01

    Optical measurement was done on oil cloud sedimentation before and after passing through nose and out tracheal cannula. The filtering unit which also provides most resistance to flow is maximal turbinates. Nasal cavity is more complex than in man or some other animals, so filtration may be different. Calculation of particle inertia and filter channel width shows that particles > 7 ..mu..m would impact on curves or projections. Particles less than 1.5 ..mu..m should penetrate freely, but low molecular weight gases would be caught by diffusion. The higher the flow, the better the filtration (inertial settling). Broadly summarizing, at ordinary flow rates and nasal resistances, essentially all drops > 7 ..mu..m will be removed. About 50% of 3-..mu.. drops will be removed. < 1.5-..mu..m drops will penetrate.

  11. Bat white-nose syndrome in North America

    Science.gov (United States)

    Blehert, David S.; Lorch, Jeffrey M.; Ballmann, Anne E.; Cryan, Paul M.; Meteyer, Carol U.

    2011-01-01

    * The newly described fungus, Geomyces destructans, causes an invasive skin infection in bats and is the likely agent of white-nose syndrome (WNS). * With immune system functions and body temperatures reduced during hibernation, bats may be unusually susceptible to a pathogenic fungus such as G. destructans. * WNS was first observed in a popular show cave near Albany, New York, leading some investigators to suspect that a visitor inadvertently introduced G. destructans at this site, triggering a wider WNS outbreak in North America. * Biologists trying to manage WNS within North American bat populations face major challenges, including the variety of susceptible host species, incredible dispersal capabilities of bats, difficulties in treating such populations, and persistence of the pathogen in their vulnerable underground habitats.

  12. An Artificial Nose Based on Microcantilever Array Sensors

    Energy Technology Data Exchange (ETDEWEB)

    Lang, H P [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Ramseyer, J P [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Grange, W [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Braun, T [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Schmid, D [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Hunziker, P [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Jung, C [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Hegner, M [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Gerber, C [National Center of Competence in Research for Nanoscale Science, Institute of Physics of Univesity of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland)

    2007-03-15

    We used microfabricated cantilever array sensors for an artificial nose setup. Each cantilever is coated on its top surface with a polymer layer. Volatile gaseous analytes are detected by tracking the diffusion process of the molecules into the polymer layers, resulting in swelling of the polymer layers and therewith bending of the cantilevers. From the bending pattern of all cantilevers in the array, a characteristic 'fingerprint' of the analyte is obtained, which is evaluated using principal component analysis. In a flow of dry nitrogen gas, the bending of the cantilevers is reverted to its initial state before exposure to the analyte, which allows reversible and reproducible operation of the sensor. We show examples of detection of solvents, perfume essences and beverage flavors. In a medical application, the setup provides indication of presence of diseases in patient's breath samples.

  13. The method of the transfer matrix applied to the study of the electronic properties of the Kronig- Penney model with structural disorder

    International Nuclear Information System (INIS)

    Miranda S, Anabel; Landauro S, Carlos

    2008-01-01

    In the present work the transfer matrix method is employed to study the electronic properties of the Kronig-Penney model including disorder in the periodic system. The results show that although the electronic properties are very similar to the corresponding periodic case, disorder in the system produces a decrease of the transmission in the whole range of energies which indicates clearly a reduction of the electronic transport (conductivity) due to the disorder in the system. (author)

  14. Histopathologic criteria to confirm white-nose syndrome in bats.

    Science.gov (United States)

    Meteyer, Carol Uphoff; Buckles, Elizabeth L; Blehert, David S; Hicks, Alan C; Green, D Earl; Shearn-Bochsler, Valerie; Thomas, Nancy J; Gargas, Andrea; Behr, Melissa J

    2009-07-01

    White-nose syndrome (WNS) is a cutaneous fungal disease of hibernating bats associated with a novel Geomyces sp. fungus. Currently, confirmation of WNS requires histopathologic examination. Invasion of living tissue distinguishes this fungal infection from those caused by conventional transmissible dermatophytes. Although fungal hyphae penetrate the connective tissue of glabrous skin and muzzle, there is typically no cellular inflammatory response in hibernating bats. Preferred tissue samples to diagnose this fungal infection are rostral muzzle with nose and wing membrane fixed in 10% neutral buffered formalin. To optimize detection, the muzzle is trimmed longitudinally, the wing membrane is rolled, and multiple cross-sections are embedded to increase the surface area examined. Periodic acid-Schiff stain is essential to discriminate the nonpigmented fungal hyphae and conidia. Fungal hyphae form cup-like epidermal erosions and ulcers in the wing membrane and pinna with involvement of underlying connective tissue. In addition, fungal hyphae are present in hair follicles and in sebaceous and apocrine glands of the muzzle with invasion of tissue surrounding adnexa. Fungal hyphae in tissues are branching and septate, but the diameter and shape of the hyphae may vary from parallel walls measuring 2 microm in diameter to irregular walls measuring 3-5 microm in diameter. When present on short aerial hyphae, curved conidia are approximately 2.5 microm wide and 7.5 microm in curved length. Conidia have a more deeply basophilic center, and one or both ends are usually blunt. Although WNS is a disease of hibernating bats, severe wing damage due to fungal hyphae may be seen in bats that have recently emerged from hibernation. These recently emerged bats also have a robust suppurative inflammatory response.

  15. Histopathologic criteria to confirm white-nose syndrome in bats

    Science.gov (United States)

    Meteyer, Carol U.; Buckles, Elizabeth L.; Blehert, David S.; Hicks, Alan C.; Green, David E.; Shearn-Bochsler, Valerie I.; Thomas, Nancy J.; Gargas, Andrea; Behr, Melissa

    2009-01-01

    White-nose syndrome (WNS) is a cutaneous fungal disease of hibernating bats associated with a novel Geomyces sp. fungus. Currently, confirmation of WNS requires histopathologic examination. Invasion of living tissue distinguishes this fungal infection from those caused by conventional transmissible dermatophytes. Although fungal hyphae penetrate the connective tissue of glabrous skin and muzzle, there is typically no cellular inflammatory response in hibernating bats. Preferred tissue samples to diagnose this fungal infection are rostral muzzle with nose and wing membrane fixed in 10% neutral buffered formalin. To optimize detection, the muzzle is trimmed longitudinally, the wing membrane is rolled, and multiple cross-sections are embedded to increase the surface area examined. Periodic acid-Schiff stain is essential to discriminate the nonpigmented fungal hyphae and conidia. Fungal hyphae form cup-like epidermal erosions and ulcers in the wing membrane and pinna with involvement of underlying connective tissue. In addition, fungal hyphae are present in hair follicles and in sebaceous and apocrine glands of the muzzle with invasion of tissue surrounding adnexa. Fungal hyphae in tissues are branching and septate, but the diameter and shape of the hyphae may vary from parallel walls measuring 2 ??m in diameter to irregular walls measuring 3-5 ??m in diameter. When present on short aerial hyphae, curved conidia are approximately 2.5 ??m wide and 7.5 ??m in curved length. Conidia have a more deeply basophilic center, and one or both ends are usually blunt. Although WNS is a disease of hibernating bats, severe wing damage due to fungal hyphae may be seen in bats that have recently emerged from hibernation. These recently emerged bats also have a robust suppurative inflammatory response.

  16. A Novel Extreme Learning Machine Classification Model for e-Nose Application Based on the Multiple Kernel Approach.

    Science.gov (United States)

    Jian, Yulin; Huang, Daoyu; Yan, Jia; Lu, Kun; Huang, Ying; Wen, Tailai; Zeng, Tanyue; Zhong, Shijie; Xie, Qilong

    2017-06-19

    A novel classification model, named the quantum-behaved particle swarm optimization (QPSO)-based weighted multiple kernel extreme learning machine (QWMK-ELM), is proposed in this paper. Experimental validation is carried out with two different electronic nose (e-nose) datasets. Being different from the existing multiple kernel extreme learning machine (MK-ELM) algorithms, the combination coefficients of base kernels are regarded as external parameters of single-hidden layer feedforward neural networks (SLFNs). The combination coefficients of base kernels, the model parameters of each base kernel, and the regularization parameter are optimized by QPSO simultaneously before implementing the kernel extreme learning machine (KELM) with the composite kernel function. Four types of common single kernel functions (Gaussian kernel, polynomial kernel, sigmoid kernel, and wavelet kernel) are utilized to constitute different composite kernel functions. Moreover, the method is also compared with other existing classification methods: extreme learning machine (ELM), kernel extreme learning machine (KELM), k-nearest neighbors (KNN), support vector machine (SVM), multi-layer perceptron (MLP), radical basis function neural network (RBFNN), and probabilistic neural network (PNN). The results have demonstrated that the proposed QWMK-ELM outperforms the aforementioned methods, not only in precision, but also in efficiency for gas classification.

  17. On the impact of a concave nosed axisymmetric body on a free surface

    Science.gov (United States)

    Mathai, Varghese; Govardhan, Raghuraman N.; Arakeri, Vijay H.

    2015-02-01

    We report on an experimental study of the vertical impact of a concave nosed axisymmetric body on a free surface. Previous studies have shown that bodies with a convex nose, like a sphere, produce a well defined splash with a relatively large cavity behind the model. In contrast, we find that with a concave nose, there is hardly a splash and the cavity extent is greatly reduced. This may be explained by the fact that in the concave nosed case, the initial impact is between a confined air pocket and the free surface unlike in the convex nosed case. From measurements of the unsteady pressure in the concave nose portion, we show that in this case, the maximum pressures are significantly lower than the classically expected "water hammer" pressures and also lower than those generally measured on other geometries. Thus, the presence of an air pocket in the case of a concave nosed body adds an interesting dimension to the classical problem of impact of solid bodies on to a free surface.

  18. Directionality of nose-emitted echolocation calls from bats without a nose-leaf (Plecotus auritus)

    DEFF Research Database (Denmark)

    Jakobsen, Lasse; Hallam, John; Moss, Cynthia F

    2018-01-01

    All echolocating bats and whales measured to date emit a directional bio-sonar beam that affords them a number of advantages over an omni-directional beam, i.e. reduced clutter, increased source level and inherent directional information. In this study we investigated the importance...... of a directional sound emission for navigation through echolocation by measuring the sonar beam of brown long-eared bats, Plecotus auritusP. auritus emits sound through the nostrils but has no external appendages to readily facility a directional sound emission as found in most nose emitters. The study shows...... that P. auritus, despite the lack of an external focusing apparatus, emits a directional echolocation beam (Directivity index=13 dB) and that the beam is more directional vertically (-6 dB angle at 22°) than horizontally (-6dB angle at 35°). Using a simple numerical model we find that the recorded...

  19. Nuclear resonance vibrational spectroscopy applied to [Fe(OEP)(NO)]: the vibrational assignments of five-coordinate ferrous heme-nitrosyls and implications for electronic structure.

    Science.gov (United States)

    Lehnert, Nicolai; Galinato, Mary Grace I; Paulat, Florian; Richter-Addo, George B; Sturhahn, Wolfgang; Xu, Nan; Zhao, Jiyong

    2010-05-03

    -O bonds are 2.83-2.94 (based on the DFT functional applied) and about 12.15 mdyn/A, respectively. The electronic structures of 5C ferrous heme-nitrosyls in different model complexes are then analyzed, and variations in their properties based on different porphyrin substituents are explained. Finally, the shortcomings of different DFT functionals in describing the axial FeNO subunit in heme-nitrosyls are elucidated.

  20. Combination of an e-nose, an e-tongue and an e-eye for the characterisation of olive oils with different degree of bitterness

    Energy Technology Data Exchange (ETDEWEB)

    Apetrei, C., E-mail: apetreic@ugal.ro [Department of Chemistry, Faculty of Sciences, European Excellence Research Centre for Environmental Problems, ' Dunarea de Jos' University of Galati (Romania) (Spain); Apetrei, I.M.; Villanueva, S. [Department of Condensed Matter Physics, Sciences Faculty, University of Valladolid, Prado de la Magdalena s/n, 47005 Valladolid (Spain); Saja, J.A. de, E-mail: sajasaez@fmc.uva.es [Department of Condensed Matter Physics, Sciences Faculty, University of Valladolid, Prado de la Magdalena s/n, 47005 Valladolid (Spain); Gutierrez-Rosales, F., E-mail: rosales@cica.es [Instituto de la Grasa de Sevilla, CSIC, Avda. Padre Garcia Tejero, 4, Sevilla, E-41012 (Spain); Rodriguez-Mendez, M.L., E-mail: mluz@dali.eis.uva.es [Department of Inorganic Chemistry, E.T.S. Ingenieros Industriales, Po del Cauce s/n, 47011 Valladolid (Spain)

    2010-03-17

    An electronic panel has been used to characterise the organoleptic characteristics of twenty-five extra virgin olive oils from varieties Hojiblanca, Picual and Arbequina, with different degree of bitterness. The method consists in the combination of three systems: electronic nose, electronic tongue and electronic eye. The Principal Component Analysis (PCA), where PC1, PC2 and PC3 explained 59% of the total variance between the samples, has demonstrated that the capability of discrimination of the combined system is superior to that obtained with the three instruments separately. This improvement is due to the increased information extracted from each sample. Partial Least Squares-Discriminant Analysis (PLS-DA) has allowed separation of the groups in function of olive variety with a root mean square error of prediction (RMSEP) lower than 0.099. Using PLS1 and PLS2 regression models, good correlations have been found between the signals obtained from the electronic tongue and the polyphenolic content (measured by chromatographic methods) or the bitterness index (scored by a panel of experts) with correlation coefficients higher than 0.9 in calibration and validation. These preliminary results indicate that the combination of an e-nose, an e-tongue and an e-eye can be a useful tool for the analysis of olive oil bitterness.