WorldWideScience

Sample records for electron microscopical study

  1. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1992-01-01

    This is a report covering the research performed in the Crewe laboratory between 1964 and 1992. Because of limitations of space we have provided relatively brief summaries of the major research directions of the facility during these years. A complete bibliography has been included and we have referenced groups of pertinent publications at the beginning of each section. This report summarizes our efforts to develop better electron microscopes and chronicles many of the experimental programs, in materials science and biology, that acted both as a stimulus to better microscope design and also as a testing ground for many instrumental innovations

  2. Electron microscope studies

    Energy Technology Data Exchange (ETDEWEB)

    Crewe, A.V.; Kapp, O.H.

    1992-07-01

    This is a report covering the research performed in the Crewe laboratory between 1964 and 1992. Because of limitations of space we have provided relatively brief summaries of the major research directions of the facility during these years. A complete bibliography has been included and we have referenced groups of pertinent publications at the beginning of each section. This report summarizes our efforts to develop better electron microscopes and chronicles many of the experimental programs, in materials science and biology, that acted both as a stimulus to better microscope design and also as a testing ground for many instrumental innovations.

  3. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1990-01-01

    Our laboratory has made significant progress this year in devising improved electron-optical systems, in studying invertebrate hemoglobins with the STEM, and in achieving a workable sub-angstrom STEM. Our goal in electron optics is to improve resolution by producing spherical and chromatic aberration coefficients with signs opposite those of magnetic lenses. We have progressed toward this goal through calculations that explore the addition of electrodes to electron mirrors to reduce these two geometric aberrations and by devising a beam separation system that won't introduce asymmetrical aberrations. Some promising new designs of magnetic lenses for SEM applications have also been investigated. We have continued our exploration of the quaternary structure of the invertebrate hemoglobins and are now among the top laboratories in this area of expertise. In addition, we have overcome many of our electronic difficulties on the sub-angstrom STEM and have made significant progress toward achieving an operational system. The addition of an IBM RISC-6000 workstation to our lab has significantly increased our image processing capabilities

  4. Electron microscope studies

    International Nuclear Information System (INIS)

    Crewe, A.V.; Kapp, O.H.

    1991-01-01

    This year our laboratory has continued to make progress in the design of electron-optical systems, in the study of structure-function relationships of large multi-subunit proteins, in the development of new image processing software and in achieving a workable sub-angstrom STEM. We present an algebraic approach to the symmetrical Einzel (unipotential) lens wherein we simplify the analysis by specifying a field shape that meets some preferred set of boundary or other conditions and then calculate the fields. In a second study we generalize this approach to study of three element electrostatic lenses of which the symmetrical Einzel lens is a particular form. The purpose is to develop a method for assisting in the design of a lens for a particular purpose. In our biological work we study a stable and functional dodecameric complex of globin chains from the hemoglobin of Lumbricus terrestris. This is a complex lacking the ''linker'' subunit first imaged in this lab and required for maintenance of the native structure. In addition, we do a complete work-up on the hemoglobin of the marine polychaete Eudistylia vancouverii demonstrating the presence of a hierarchy of globin complexes. We demonstrate stable field-emission in the sub-angstrom STEM and the preliminary alignment of the beam. We continue our exploration of a algorithms for alignment of sequences of protein and DNA. Our computer facilities now include four second generation RISC workstations and we continue to take increasing advantage of the floating-point and graphical performance of these devices

  5. Transmission electron microscope studies of extraterrestrial materials

    Science.gov (United States)

    Keller, Lindsay P.

    1995-01-01

    Transmission Electron Microscopy, X-Ray spectrometry and electron-energy-loss spectroscopy are used to analyse carbon in interplanetary dust particles. Optical micrographs are shown depicting cross sections of the dust particles embedded in sulphur. Selected-area electron diffraction patterns are shown. Transmission Electron Microscope specimens of lunar soil were prepared using two methods: ion-milling and ultramicrotomy. A combination of high resolution TEM imaging and electron diffraction is used to characterize the opaque assemblages. The opaque assemblages analyzed in this study are dominated by ilmenite with lesser rutile and spinel exsolutions, and traces of Fe metal.

  6. Study of Scanning Tunneling Microscope control electronics

    International Nuclear Information System (INIS)

    Oliva, A.J.; Pancarobo, M.; Denisenko, N.; Aguilar, M.; Rejon, V.; Pena, J.L.

    1994-01-01

    A theoretical study of Scanning Tunneling Microscope control electronics is made. The knowledge of its behaviour allows us to determine accurately the region where the unstable operation could effect the measurements, and also to set the optimal working parameters. Each feedback circuitry compound is discussed as well as their mutual interaction. Different working conditions analysis and results are presented. (Author) 12 refs

  7. Electron microscope studies on nuclear track filters

    International Nuclear Information System (INIS)

    Roell, I.; Siegmon, W.

    1982-01-01

    Nuclear track filters became more and more important in various fields of application. The filtration process can be described by a set of suitable parameters. For some applications it may be necessary to know the structure of the surface and the pores themselves. In most cases the etching process yields surfaces and pore geometries that are quite different from ideal planes and cylinders. In the presented work the production of different filter types will be described. The resulting surfaces and pore structures have been investigated by means of a scanning electron microscope. (author)

  8. Electron microscope study of irradiated beryllium oxide

    International Nuclear Information System (INIS)

    Bisson, A.A.

    1965-06-01

    The beryllium oxide is studied first by fractography, before and after irradiation, using sintered samples. The fractures are examined under different aspects. The higher density sintered samples, with transgranular fractures are the most interesting for a microscopic study. It is possible to mark the difference between the 'pores' left by the sintering process and the 'bubbles' of gases that can be produced by former thermal treatments. After irradiation, the grain boundaries are very much weakened. By annealing, it is possible to observe the evolution of the gases produced by the reaction (n, 2n) and (n. α) and gathered on the grain boundaries. The irradiated beryllium oxide is afterwards studied by transmission. For that, a simple method has been used: little chips of the crushed material are examined. Clusters of point defects produced by neutrons are thus detected in crystals irradiated at the three following doses: 6 x 10 19 , 9 x 10 19 and 2 x 10 20 n f cm -2 at a temperature below 100 deg. C. For the irradiation at 6 x 10 19 n f cm -2 , the defects are merely visible, but at 2 x l0 20 n f cm -2 the crystals an crowded with clusters and the Kikuchi lines have disappeared from the micro-diffraction diagrams. The evolution of the clusters into dislocation loops is studied by a series of annealings. The activation energy (0,37 eV) calculated from the annealing curves suggests that it must be interstitials that condense into dislocation loops. Samples irradiated at high temperatures (650, 900 and 1100 deg. C) are also studied. In those specimens the size of the loops is not the same as the equilibrium size obtained after out of pile annealing at the same temperature. Those former loops are more specifically studied and their Burgers vector is determined by micro-diffraction. (author) [fr

  9. Analytical electron microscope study of eight ataxites

    Science.gov (United States)

    Novotny, P. M.; Goldstein, J. I.; Williams, D. B.

    1982-01-01

    Optical and electron optical (SEM, TEM, AEM) techniques were employed to investigate the fine structure of eight ataxite-iron meteorites. Structural studies indicated that the ataxites can be divided into two groups: a Widmanstaetten decomposition group and a martensite decomposition group. The Widmanstaetten decomposition group has a Type I plessite microstructure and the central taenite regions contain highly dislocated lath martensite. The steep M shaped Ni gradients in the taenite are consistent with the fast cooling rates, of not less than 500 C/my, observed for this group. The martensite decomposition group has a Type III plessite microstructure and contains all the chemical group IVB ataxites. The maximum taenite Ni contents vary from 47.5 to 52.7 wt % and are consistent with slow cooling to low temperatures of not greater than 350 C at cooling rates of not greater than 25 C/my.

  10. Dental Wear: A Scanning Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2014-01-01

    Full Text Available Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction studied by scanning electron microscopy (SEM. The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp, to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders. It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction.

  11. Electron microscope study of Sarcocystis sp

    Science.gov (United States)

    Zeve, V.H.; Price, D.L.; Herman, C.M.

    1966-01-01

    Sarcocystis sp. obtained from wild populations of grackles, Quiscalus quiscula (Linn.), were examined to clarify the effect of the parasite on the host. Electron micrographs are presented to show areas of muscle destruction adjacent to the parasite which appear to be mechanically produced by the parasite. The microtubules within the villus-like projections of the cyst suggest that their possible function is absorptive and/or conductive with regard to the production of a toxin or the conveyance of nutritive material to the developing cells. The proposed function of submembranous filaments and their relation to the conoid is discussed. Similarities in the ultrastructure to Toxoplasma and other protozoa tend to negate the relegation of Sarcocystis to the fungi and further emphasize its protozoan nature.

  12. Scanning electron microscopic studies on bone tumors

    International Nuclear Information System (INIS)

    Itoh, Motoya

    1978-01-01

    Surface morphological observations of benign and malinant bone tumors were made by the use of scanning electron microscopy. Tumor materials were obtained directly from patients of osteogenic sarcomas, chondrosarcomas, enchondromas, giant cell tumors and Paget's sarcoma. To compare with these human tumors, the following experimental materials were also observed: P 32 -induced rat osteogenic sarcomas with their pulmonary metastatic lesions, Sr 89 -induced transplantable mouse osteogenic sarcomas and osteoid tissues arising after artificial fractures in mice. One of the most outstanding findings was a lot of granular substances seen on cell surfaces and their intercellular spaces in osteoid or chondroid forming tissues. These substances were considered to do some parts in collaborating extracellular matrix formation. Protrusions on cell surface, such as mucrovilli were more or less fashioned by these granular substances. Additional experiments revealed these substances to be soluble in sodium cloride solution. Benign osteoid forming cells, such as osteoblasts and osteoblastic osteosarcoma cells had granular substances on their surfaces and their intercellular spaces. On the other hand, undifferentiated transplantable osteosarcoma which formed on osteoid or chondroid matrix had none of these granular substances. Consequently, the difference of surface morphology between osteosarcoma cells and osteoblasts was yet to be especially concluded. (author)

  13. Comparative study of image contrast in scanning electron microscope and helium ion microscope.

    Science.gov (United States)

    O'Connell, R; Chen, Y; Zhang, H; Zhou, Y; Fox, D; Maguire, P; Wang, J J; Rodenburg, C

    2017-12-01

    Images of Ga + -implanted amorphous silicon layers in a 110 n-type silicon substrate have been collected by a range of detectors in a scanning electron microscope and a helium ion microscope. The effects of the implantation dose and imaging parameters (beam energy, dwell time, etc.) on the image contrast were investigated. We demonstrate a similar relationship for both the helium ion microscope Everhart-Thornley and scanning electron microscope Inlens detectors between the contrast of the images and the Ga + density and imaging parameters. These results also show that dynamic charging effects have a significant impact on the quantification of the helium ion microscope and scanning electron microscope contrast. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  14. Electron-microscope study of cloud and fog nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, S; Okita, T

    1952-01-01

    Droplets of clouds on a mountain and of fog in an urban area were captured and the form, nature and size of their nuclei were studied by means of an electron-microscope and by a chamber of constant humidity. These nuclei have similar form and nature to the hygroscopic particles in haze and to the artificially produced combustion particles. No sea-salt nuclei were found in our observations, therefore, sea-spray appears to be an insignificant source of condensation nuclei. It was found that both the cloud and the fog nuclei originated in combustion products which were the mixture of hygroscopic and non-hygroscopic substances, and that the greater part of the nuclei did not contain pure sulfuric acid.

  15. Pigmentosis tubae, a new entity: light and electron microscopic study

    International Nuclear Information System (INIS)

    Herrera, G.A.; Reimann, B.E.; Greenberg, H.L.; Miles, P.A.

    1983-01-01

    The authors noted an unusual finding in the fallopian tubes of a 31-year-old woman who had received external and internal whole pelvis radiotherapy for squamous cell carcinoma of the cervix. Aggregates of macrophages containing pigment, identified in a subepithelial location, were reminiscent of melanosis coli, which is caused by abuse of anthracene-containing laxatives. Electron microscopic examination of the pigment revealed cytoplasmic material with the appearance of lipofuscin, identical to the pigment described in cases of colonic melanosis. After a careful study of possible etiologic agents, it was concluded that the pigment most likely resulted from cellular damage caused by radiotherapy. The authors are not aware of any other reported case of this entity, which will be called pigmentosis tubae

  16. Analytical Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — The Titan 80-300 is a transmission electron microscope (TEM) equipped with spectroscopic detectors to allow chemical, elemental, and other analytical measurements to...

  17. Somatic Embryos in Catharanthus roseus: A Scanning Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Junaid ASLAM

    2014-06-01

    Full Text Available Catharanthus roseus (L. G. Don is an important medicinal plant as it contains several anti-cancerous compounds, like vinblastine and vincristine. Plant tissue culture technology (organogenesis and embryogenesis has currently been used in fast mass propagating raw materials for secondary metabolite synthesis. In this present communication, scanning electron microscopic (SEM study of somatic embryos was conducted and discussed. The embryogenic callus was first induced from hypocotyls of in vitro germinated seeds on which somatic embryos, differentiated in numbers, particularly on 2,4-D (1.0 mg/L Murashige and Skoog (MS was medium. To understand more about the regeneration method and in vitro formed embryos SEM was performed. The SEM study revealed normal somatic embryo origin and development from globular to heart-, torpedo- and then into cotyledonary-stage of embryos. At early stage, the embryos were clustered together in a callus mass and could not easily be detached from the parental tissue. The embryos were often long cylindrical structure with or without typical notch at the tip. Secondary embryos were also formed on primary embryo structure. The advanced cotyledonary embryos showed prominent roots and shoot axis, which germinated into plantlets. The morphology, structure and other details of somatic embryos at various stages were presented.

  18. Electron microscopic study on radiosensitivity of uterine cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, S; Shiozawa, K; Tsukamoto, T; Noguchi, H; Tsukahara, Y [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1974-11-01

    The effects of 1000 R of tele-cobalt upon the changes in the primary lesions of uterine cervical cancer with time were studied with an electron microscope. In addition, twenty cases which were proven to have cancer tissues (10 cases of IInd stage of cancer, 8 cases of IIIrd stage of cancer and 2 cases of IVth stage of cancer) were studied. Four cases were favourably sensitive, 7 cases moderately sensitive and 9 cases unfavourably sensitive to radiation. In favourably radio-sensitive cases, the changes in the cancer cells first appeared in the nucleus. There were other changes such as local clumping of chromatin and, specifically, vacuolization of the nucleus. The changes in the endoplasmic reticulum appeared somewhat late. In addition, the disturbance of mitochondria and the decrease or disappearance of ribosomes were specifically due to radiation injury. From the point of view of changes with time, Golgi's apparatus was enlarged and the membrane of the endoplasmic reticulum was degenerated at the 1st day. At the 3rd day, vacuolization of the nucleus appeared, the nuclear corpuscles were increased, the nucleoplasm became thin, and mitochondria was enlarged and degenerated. At the 5th day, the nuclear membrane disappeared, the nucleus was destroyed, large vacuolization of the endoplasmic reticulum was seen, free ribosomes were decreased, and changes around the endoplasmic reticulum were observed. At the 7th day, collagen around the endoplasmic reticulum appeared. In favourably radiosensitive cases, individual tumor cells showed the same degeneration, which fairly corresponded to that evaluated by the histological observation. The disturbance of the cells was caused by radiation, so-called ''burning'' of the cells. Radiation protection of the cells against burning was considered in terms of their radiosensitivity.

  19. Miniaturized Environmental Scanning Electron Microscope for In Situ Planetary Studies

    Science.gov (United States)

    Gaskin, Jessica; Abbott, Terry; Medley, Stephanie; Gregory, Don; Thaisen, Kevin; Taylor , Lawrence; Ramsey, Brian; Jerman, Gregory; Sampson, Allen; Harvey, Ralph

    2010-01-01

    The exploration of remote planetary surfaces calls for the advancement of low power, highly-miniaturized instrumentation. Instruments of this nature that are capable of multiple types of analyses will prove to be particularly useful as we prepare for human return to the moon, and as we continue to explore increasingly remote locations in our Solar System. To this end, our group has been developing a miniaturized Environmental-Scanning Electron Microscope (mESEM) capable of remote investigations of mineralogical samples through in-situ topographical and chemical analysis on a fine scale. The functioning of an SEM is well known: an electron beam is focused to nanometer-scale onto a given sample where resulting emissions such as backscattered and secondary electrons, X-rays, and visible light are registered. Raster scanning the primary electron beam across the sample then gives a fine-scale image of the surface topography (texture), crystalline structure and orientation, with accompanying elemental composition. The flexibility in the types of measurements the mESEM is capable of, makes it ideally suited for a variety of applications. The mESEM is appropriate for use on multiple planetary surfaces, and for a variety of mission goals (from science to non-destructive analysis to ISRU). We will identify potential applications and range of potential uses related to planetary exploration. Over the past few of years we have initiated fabrication and testing of a proof-of-concept assembly, consisting of a cold-field-emission electron gun and custom high-voltage power supply, electrostatic electron-beam focusing column, and scanning-imaging electronics plus backscatter detector. Current project status will be discussed. This effort is funded through the NASA Research Opportunities in Space and Earth Sciences - Planetary Instrument Definition and Development Program.

  20. Electron microscopic study on SrGdMnO4

    International Nuclear Information System (INIS)

    Nakano, Hiromi; Ishizawa, Nobuo; Kamegashira, Naoki; Zulhadjri; Shishido, Toetsu

    2006-01-01

    Single crystals of SrGdMnO 4 have been synthesized by the floating zone method. The structure was characterized as the K 2 NiF 4 -type, using X-ray diffraction (XRD) and a transmission electron microscope (TEM). Presence of weak reflections breaking the archetypal tetragonal symmetry was observed from the selected area diffraction (SAD). The compound was found to have an orthorhombic unit cell of a ≅ b = 0.532(4) nm, c = 1.271(6) nm, by taking the a and b axes along the diagonal directions on the basal plane of the tetragonal archetype. Structural change occurred around 1018 K. The weak reflections disappeared in the SAD pattern, suggesting that crystal is of the archetype above 1018 K

  1. Scanning Auger Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  2. Electron microscopical studies of the common bile duct in reindeer

    Directory of Open Access Journals (Sweden)

    Timo Rahko

    1990-08-01

    Full Text Available In a previous publication the authors have described some ultrastructural characteristics of granulated cells in the common bile duct of the reindeer. On the basis of the same material, electron microscopic observations on other tissue elements of bile duct wall are now reported. The surface and glandular epithelium were composed of tall columnar epithelial cells with villous structures on the luminal surfaces. The parietal cytoplasmic membranes of epithelial cells were equipped with intercellular desmosomes while intraepithelial globule leucocytes did not form any junctional complex with other cells. Apical cytoplasmic areas of superficial epithelial cells showed electron-dense small bodies possibly consisting of mucinous substances. The goblet and deep glandular cells, on the other hand, contained numerous large mucin granules with less electron-dense matrices. It appears that their secretions are more abundant than those in superficial epithelial cells which obviously are absorptive as their main function. The nuclei and other cytoplasmic organelles showed profiles similar to those in epithelial cells generally. The lumen of the bile ducts was usually empty or contained fine-granular or amorphous material. An unusual feature was the presence of parts of globule leucocytes or even almost whole cells occurring freely in ductal secretions.Elektronimikroskooppinen tutkimus yhteisen sappikäytävän rakenteesta porolla.Abstract in Finnish / Yhteenveto: Aikaisemmassa julkaisussa tekijät kuvasivat poron yhteisen sappikäytävän (ductus hepaticus communis seinämän jyväsellisten solujen hienorakennetta. Tässä artikkelissa selostetaan saman aineiston perusteella (6 tervettä teurasporoa elektronimikroskooppisia havaintoja sappikäytäväseinämän muista kudosrakenteista. Sappikäytäväseinämän pinta- ja rauhasepiteeli koostuu korkeista epiteelisoluista. Pinnallisia epiteelisoluja kattavat säännölliset mikrovillukset, ja niillä on vain v

  3. [Scanning electron microscope study of chemically disinfected endodontic files].

    Science.gov (United States)

    Navarro, G; Mateos, M; Navarro, J L; Canalda, C

    1991-01-01

    Forty stainless steel endodontic files were observed at scanning electron microscopy after being subjected to ten disinfection cycles of 10 minutes each one, immersed in different chemical disinfectants. Corrosion was not observed on the surface of the files in circumstances that this study was made.

  4. A fluorescence scanning electron microscope

    International Nuclear Information System (INIS)

    Kanemaru, Takaaki; Hirata, Kazuho; Takasu, Shin-ichi; Isobe, Shin-ichiro; Mizuki, Keiji; Mataka, Shuntaro; Nakamura, Kei-ichiro

    2009-01-01

    Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital camera microscope unit and this hybrid instrument was named a fluorescence SEM (FL-SEM). In the labeling of FL-SEM samples, both Fluolid, which is an organic EL dye, and Alexa Fluor, were employed. We successfully demonstrated that the FL-SEM is a simple and practical tool for correlative fluorescence and electron microscopy.

  5. Scanning electron microscope

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The principle underlying the design of the scanning electron microscope (SEM), the design and functioning of SEM are described. Its applications in the areas of microcircuitry and materials science are outlined. The development of SEM in India is reviewed. (M.G.B.)

  6. Microscopical Studies of Structural and Electronic Properties of Semiconductors

    CERN Multimedia

    2002-01-01

    The electronic and structural properties of point defects in semiconductors, e.g. radiation defects, impurities or passivating defects can excellently be studied by the hyperfine technique of Perturbed Angular Correlation (PAC). The serious limitation of this method, the small number of chemically different radioactive PAC probe atoms can be widely overcome by means of ISOLDE. Providing shortliving isotopes, which represent common dopants as well as suitable PAC probe atoms, the ISOLDE facility enables a much broader application of PAC to problems in semiconductor physics.\\\\ Using the probe atom $^{111m}$ Cd , the whole class of III-V compounds becomes accessible for PAC investigations. First successful experiments in GaAs, InP and GaP have been performed, concerning impurity complex formation and plasma induced defects. In Si and Ge, the electronic properties~-~especially their influence on acceptor-donor interaction~-~could be exemplarily st...

  7. Oxidation mechanism of nickel particles studied in an environmental transmission electron microscope

    DEFF Research Database (Denmark)

    Jeangros, Q.; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2014-01-01

    The oxidation of nickel particles was studied in situ in an environmental transmission electron microscope in 3.2 mbar of O2 between ambient temperature and 600°C. Several different transmission electron microscopy imaging techniques, electron diffraction and electron energy-loss spectroscopy were...... diffusion of Ni2+ along NiO grain boundaries, self-diffusion of Ni2+ ions and vacancies, growth of NiO grains and nucleation of voids at Ni/NiO interfaces. We also observed the formation of transverse cracks in a growing NiO film in situ in the electron microscope....

  8. Transmission electron microscopic study of reduced Ca2UO5

    International Nuclear Information System (INIS)

    Krasevec, V.; Prodan, A.; Holc, J.; Kolar, D.

    1983-01-01

    Structural changes of Ca 2 UO 5 during reduction in hydrogen were studied by transmission electron microscopy. It was shown that monoclinic Ca 2 UO 5 changes into triclinic Ca 4 U 2 O 9 . They are related, respectively, to the fluorite and the bixbyite (C-M 2 O 3 ) structures, so that the product is a superstructure of the latter. Reduction occurs along the (100)/sub t/ planes originating from the (006)/sub m/ planes of the parent structure by diminishing the coordination number of the Ca cation from 7 to 6. 5 figures

  9. An Electron Microscope Study of the Yeast Pityrosporum ovale

    NARCIS (Netherlands)

    Kreger-van Rij, N.J.W.; Veenhuis, M.

    1970-01-01

    Cells of Pityrosporum ovale were prepared for electron microscopy by different methods of fixation and embedding, all of them causing some degree of damage to the cells. Apart from the usual organelles seen in other yeast cells, a body was found which showed an electron-dense outer layer and an

  10. Electron microscope phase enhancement

    Science.gov (United States)

    Jin, Jian; Glaeser, Robert M.

    2010-06-15

    A microfabricated electron phase shift element is used for modifying the phase characteristics of an electron beam passing though its center aperture, while not affecting the more divergent portion of an incident beam to selectively provide a ninety-degree phase shift to the unscattered beam in the back focal plan of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. One application of the element is to increase the contrast of an electron microscope for viewing weakly scattering samples while in focus. Typical weakly scattering samples include biological samples such as macromolecules, or perhaps cells. Preliminary experimental images demonstrate that these devices do apply a ninety degree phase shift as expected. Electrostatic calculations have been used to determine that fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size aperture is about 5:1. Calculations are underway to determine the feasibility of aspect smaller aspect ratios of about 3:1 and about 2:1.

  11. Ant-egg cataract. An electron microscopic study

    DEFF Research Database (Denmark)

    Schrøder, H D; Nissen, S H

    1979-01-01

    an intermittent growth of the structure. In the ant-eggs, as well as in some areas separate from these, membrane limited cytoplasmic bodies could be seen in many cases, the membranes of which were partly joint and partly separated by an electron dense material. It is suggested that the calcifications seen...

  12. Forensic Scanning Electron Microscope

    Science.gov (United States)

    Keeley, R. H.

    1983-03-01

    The scanning electron microscope equipped with an x-ray spectrometer is a versatile instrument which has many uses in the investigation of crime and preparation of scientific evidence for the courts. Major applications include microscopy and analysis of very small fragments of paint, glass and other materials which may link an individual with a scene of crime, identification of firearms residues and examination of questioned documents. Although simultaneous observation and chemical analysis of the sample is the most important feature of the instrument, other modes of operation such as cathodoluminescence spectrometry, backscattered electron imaging and direct x-ray excitation are also exploited. Marks on two bullets or cartridge cases can be compared directly by sequential scanning with a single beam or electronic linkage of two instruments. Particles of primer residue deposited on the skin and clothing when a gun is fired can be collected on adhesive tape and identified by their morphology and elemental composition. It is also possible to differentiate between the primer residues of different types of ammunition. Bullets may be identified from the small fragments left behind as they pass through the body tissues. In the examination of questioned documents the scanning electron microscope is used to establish the order in which two intersecting ink lines were written and to detect traces of chemical markers added to the security inks on official documents.

  13. A scanning electron microscopic study of biliary stent materials

    NARCIS (Netherlands)

    van Berkel, A. M.; van Marle, J.; van Veen, H.; Groen, A. K.; Huibregtse, K.

    2000-01-01

    Clogging of biliary stents remains an important problem. In vitro studies have shown less sludge formation in Teflon stents. Recently, clinical studies with Teflon stents have produced contradictory results. The aim of this study was to investigate whether the surface properties of the

  14. Histological and electron microscopic study of the postulated ...

    African Journals Online (AJOL)

    Di(2-ethylhexyl)phthalate [DEHP] is a plasticizer (softener) used to increase the flexibility of polyvinyl chloride (plastic). Animal studies following acute and chronic exposure of DEHP show several toxic changes in many organs including the liver. There have been no studies of compound specific techniques for reducing ...

  15. Secondary mineralization in carious lesions of human dentin. Electron-probe, electron microscope, and electron diffraction studies

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H [Tokyo Dental Coll. (Japan)

    1975-02-01

    Dentinal carious lesions having a remineralized surface layer were studied by means electron-probe microanalysis, electron microscopy, electron diffraction. As the results of electron-probe study, F, Mg, and Na were found to be distributed mainly in the remineralized surface layer and S in the decalcified region where decreases in Ca, P, and Mg concentration were usually observed. The decrease in Mg concentration always started earlier than that of Ca and P concentration. Electron microscope and electron diffraction studies revealed that apatic crystals in the remineralized surface layer were much larger than those in the intact dentin. Although they were less conspicuous, crystals in the decalcified region also were larger than those in the intact region. Dentinal tubules, occluded by many crystals, were frequently seen during the observations. Crystals in the tubules varied in morphology, showing granular, needle, rhomboid, and tabular shapes. By means of electron diffraction, the granular- or needle-shaped crystals were identified as apatite and the rhomboid-shaped crystals as whitlockite. Some of the tabular-shaped crystals appeared to be cotacalcium phosphate.

  16. Transmission electron microscope CCD camera

    Science.gov (United States)

    Downing, Kenneth H.

    1999-01-01

    In order to improve the performance of a CCD camera on a high voltage electron microscope, an electron decelerator is inserted between the microscope column and the CCD. This arrangement optimizes the interaction of the electron beam with the scintillator of the CCD camera while retaining optimization of the microscope optics and of the interaction of the beam with the specimen. Changing the electron beam energy between the specimen and camera allows both to be optimized.

  17. Facilities for in situ ion beam studies in transmission electron microscopes

    International Nuclear Information System (INIS)

    Allen, C.W.; Ohnuki, S.; Takahashi, H.

    1993-08-01

    Interfacing an ion accelerator to a transmission electron microscope (TEM) allows the analytical functions of TEM imaging and electron diffraction from very small regions to be employed during ion-irradiation effects studies. At present there are ten such installations in Japan, one in France and one in the USA. General specifications of facilities which are operational in 1993 are summarized, and additional facilities which are planned or being proposed are briefly described

  18. Pleomorphic (giant cell) carcinoma of the intestine. An immunohistochemical and electron microscopic study

    DEFF Research Database (Denmark)

    Bak, Martin; Teglbjaerg, P S

    1989-01-01

    reaction for neuron-specific enolase (NSE) was found in three tumors and a positive reaction for chromogranin was found in one tumor. On electron microscopic study, intracytoplasmic whorls of intermediate filaments were seen in the perinuclear area. Dense core "neurosecretory" granules were rarely seen......Pleomorphic (giant cell) carcinomas have been described in the lungs, thyroid, pancreas, and gallbladder. Two pleomorphic carcinomas of the small bowel and two of the large bowel are presented. On light microscopic study, the carcinomas were solid, without squamous or glandular differentiation...

  19. Accumulation of enriched uranium UO2F2 in ultrastructure as studied by electron microscopic autoradiography

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Wang Yuanchang

    1992-01-01

    A study was made on the retention of soluble enriched uranium UO 2 F 2 in ultrastructure by electron microscopic autoradiography. The early dynamic accumulation of radioactivity in the body showed that enriched uranium UO 2 F 2 was mainly localized in kidneys, especially accumulated in epithelial cells of proximal convoluted tubules leading to degeneration and necrosis of the tubules. In liver cells, enriched uranium UO 2 F 2 at first deposited in nuclei of the cells and in soluble proteins of the plasma, and later accumulated selectively in mitochondria and lysosomes. On electron microscopic autoradiographic study it was shown that the dynamic retention of radioactivity of enriched uranium UO 2 F 2 in skeleton increased steadily through the time period of exposure. Enriched uranium UO 2 F 2 chiefly deposited in nuclei and mitochondria of osteoblasts as well as of osteoclasts

  20. Study of skin of an Egyptian mummy using a scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Mańkowska-Pliszka Hanna

    2017-06-01

    Full Text Available The first study of modified human remains using an electron microscope was carried out at the end of the 1950 and in 1979 the first result of the study involving a scanning electron microscope (SEM was published for the first time. The study was mainly focused on the structure of tissues and cells. With the help of this technique cell and tissue elements, viruses and bacterial endospores as well as the structure of epithelium and the collagen contents of dermis were identified and described. In the above-mentioned case the object of the study using a SEM was a free part of the right hand (forearm with the dorsal and palmar parts of hand of unknown origin, with signs of mummification revealed during microscopic analysis. Our study was aimed at finding the answer to the question if the mummification of the studied limb was natural or intentional, and if the study using a SEM could link the anonymous remains with ancient Egypt.

  1. Irradiation-related amorphization and crystallization: In situ transmission electron microscope studies

    International Nuclear Information System (INIS)

    Allen, C.W.

    1994-01-01

    Interfacing an ion accelerator to a transmission electron microscope (TEM) allows the analytical functions of TEM imaging and diffraction to be employed during ion-irradiation effects studies. At present there are twelve such installations in Japan, one in France and one in the US. This paper treats several aspects of in situ studies involving electron and ion beam induced and enhanced phase transformations and presents results of several in situ experiments to illustrate the dynamics of this approach in the materials science of irradiation effects. The paper describes the ion- and electron-induced amorphization of CuTi; the ion-irradiation-enhanced transformation of TiCr 2 ; and the ion- and electron-irradiation-enhanced crystallization of CoSi 2

  2. Transmission electron microscope studies of crystalline LiNbO3

    International Nuclear Information System (INIS)

    Pareja, R.; Gonzalez, R.; Chen, Y.

    1984-01-01

    Transmission electron microscope investigations in both as-grown and hydrogen-reduced LiNbO 3 reveal that niobium oxide precipitates can be produced by in situ irradiations in the electron microscope. The precipitation process is produced by a combined effect of ionizing electrons and the thermal heating of the specimens during irradiation. It is proposed that the composition of the precipitates is primarily Nb 2 O 5

  3. The interperiosteo-dural concept applied to the perisellar compartment: a microanatomical and electron microscopic study.

    Science.gov (United States)

    François, Patrick; Travers, Nadine; Lescanne, Emmanuel; Arbeille, Brigitte; Jan, Michel; Velut, Stéphane

    2010-11-01

    The dura mater has 2 dural layers: the endosteal layer (outer layer), which is firmly attached to the bone, and the meningeal layer (inner layer), which directly covers the brain. These 2 dural layers join together in the middle temporal fossa or the convexity and separate into the orbital, lateral sellar compartment (LSC), or spinal epidural space to form the extradural neural axis compartment (EDNAC). The aim of this work was to anatomically verify the concept of the EDNAC by using electron microscopy. The authors studied the cadaveric heads obtained from 13 adults. Ten of the specimens (or 20 perisellar areas) were injected with colored latex and fixed in formalin. They carefully removed each brain to allow a superior approach to the perisellar area. The 3 other specimens were studied by microscopic and ultrastructural methods to describe the EDNAC in the perisellar area. Special attention was paid to the dural layers surrounding the perisellar area. The authors studied the anatomy of the meningeal architecture of the LSC, the petroclival venous confluence, the orbit, and the trigeminal cave. After dissection, the authors took photographs of the dural layers with the aid of optical magnification. The 3 remaining heads, obtained from fresh cadavers, were prepared for electron microscopic study. The EDNAC is limited by the endosteal layer and the meningeal layer and contains fat and/or venous blood. The endosteal layer and meningeal layer were not identical on electron microscopy; this finding can be readily related to the histology of the meninges. In this study, the authors demonstrated the existence of the EDNAC concept in the perisellar area by using dissected cadaveric heads and verified the reality of the concept of the meningeal layer with electron microscopy. These findings clearly demonstrated the existence of the EDNAC, a notion that has generally been accepted but never demonstrated microscopically.

  4. Electron microscopic study of the spilt irradiation effects on the rat parotid ductal cells

    International Nuclear Information System (INIS)

    Kim, Sung Soo; Lee, Sang Rae

    1988-01-01

    This study was designed to investigate the effects of split irradiation on the salivary ductal cells, especially on the intercalated cells of the rat parotid glands. For this study, 24 Sprague-Dawley strain rats were irradiated on the head and neck region with two equal split doses of 9 Gy for a 4 hours interval by Co-60 teletherapy unit, Picker's mode l 4M 60. The conditions of irradiation were that field size, dose rate, SSD and depth were 12 X 5 cm, 222 cGy/min, 50 cm and 1 cm, respectively. The experimental animals were sacrificed 1, 2, 3, 6, 12, hours and 1, 3, 7, days after the irradiation and the changes of the irradiated intercalated cells of the parotid glands were examined under light and electron microscope. The results were as follows: 1. By the split irradiation, the degenerative changes of intercalated cells of the parotid glands appeared at 3 hours after irradiation and the most severe cellular degeneration observed at 6 hours after irradiation. The repair processes began from 12 hours after irradiation and have matured progressively. 2. Under electron microscope, loss of nuclear membrane, microvilli and secretory granules, derangement of chromosomes, degeneration of cytoplasm, atrophy or reduction of intracytoplasmic organelles were observed in the intercalated ductal cells after split irradiation. 3. Under light microscope, derangement of ductal cells, widening of cytoplasms and nuclei, hyperchromatism and proliferation of ductal cells were observed in intercalated ducts after split irradiation.

  5. A scanning electron microscopic study of 34 cases of acute granulocytic, myelomonocytic, monoblastic and histiocytic leukemia.

    Science.gov (United States)

    Polliack, A; McKenzie, S; Gee, T; Lampen, N; de Harven, E; Clarkson, B D

    1975-09-01

    This report describes the surface architecture of leukemic cells, as seen by scanning electron microscopy in 34 patients with acute nonlymphoblastic leukemia. Six patients with myeloblastic, 4 with promyelocytic, 10 with myelomonocytic, 8 with monocytic, 4 with histiocytic and 2 with undifferentiated leukemia were studied. Under the scanning electron microscope most leukemia histiocytes and monocytes appeared similar and were characterized by the presence of large, well developed broad-based ruffled membranes or prominent raised ridge-like profiles, resembling ithis respect normal monocytes. Most cells from patients with acute promyelocytic or myeloblastic leukemia exhibited narrower ridge-like profiles whereas some showed ruffles or microvilli. Patients with myelomonocytic leukemia showed mixed populations of cells with ridge-like profiles and ruffled membranes whereas cells from two patients with undifferentiated leukemia had smooth surfaces, similar to those encountered in cells from patients with acute lymphoblastic leukemia. It appears that nonlymphoblastic and lymphoblastic leukemia cells (particularly histiocytes and monocytes) can frequently be distinquished on the basis of their surface architecture. The surface features of leukemic histiocytes and monocytes are similar, suggesting that they may belong to the same cell series. The monocytes seem to have characteristic surface features recognizable with the scanning electron microscope and differ from most cells from patients with acute granulocytic leukemia. Although overlap of surface features and misidentification can occur, scanning electron microscopy is a useful adjunct to other modes of microscopy in the study and diagnosis of acute leukemia.

  6. Analytical electron microscope study of the omega phase transformation in a zirconium--niobium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Zaluzec, N.J.

    1979-06-01

    An in-situ study of the as-quenched omega phase transformation in Zr--15% Nb was conducted between the temperatures of 77 and 300/sup 0/K using analytical electron microscopy. The domain size of the omega regions observed in this investigation was on the order of 30 A, consistent with previous observations in this system. No alignment of omega domains along <222> directions of the bcc lattice was observed and in-situ thermal cycling experiments failed to produce a long period structure of alternating ..beta.. and ..omega.. phase regions as predicted by one theory of this transformation. Several techniques of microstructural analysis were developed, refined, and standardized. Grouped under the general classification of Analytical Electron Microscopy (AEM) they provide the experimentalist with a unique tool for the microcharacterization of solids, allowing semiquantitative to quantitative analysis of the morphology, crystallography, elemental composition, and electronic structure of regions as small as 20 A in diameter. These techniques have complications, and it was necessary to study the AEM system used in this work so that instrumental artifacts which invalidate the information produced in the microscope environment might be eliminated. Once these factors had been corrected, it was possible to obtain a wealth of information about the microvolume of material under investigation. The microanalytical techniques employed during this research include: energy dispersive x-ray spectroscopy (EDS) using both conventional and scanning transmission electron microscopy (CTEM, STEM), transmission scanning electron diffraction (TSED), the stationary diffraction pattern technique, and electron energy loss spectroscopy (ELS) using a dedicated scanning transmission electron microscope (DSTEM).

  7. Analytical electron microscope study of the omega phase transformation in a zirconium--niobium alloy

    International Nuclear Information System (INIS)

    Zaluzec, N.J.

    1979-06-01

    An in-situ study of the as-quenched omega phase transformation in Zr--15% Nb was conducted between the temperatures of 77 and 300 0 K using analytical electron microscopy. The domain size of the omega regions observed in this investigation was on the order of 30 A, consistent with previous observations in this system. No alignment of omega domains along directions of the bcc lattice was observed and in-situ thermal cycling experiments failed to produce a long period structure of alternating β and ω phase regions as predicted by one theory of this transformation. Several techniques of microstructural analysis were developed, refined, and standardized. Grouped under the general classification of Analytical Electron Microscopy (AEM) they provide the experimentalist with a unique tool for the microcharacterization of solids, allowing semiquantitative to quantitative analysis of the morphology, crystallography, elemental composition, and electronic structure of regions as small as 20 A in diameter. These techniques have complications, and it was necessary to study the AEM system used in this work so that instrumental artifacts which invalidate the information produced in the microscope environment might be eliminated. Once these factors had been corrected, it was possible to obtain a wealth of information about the microvolume of material under investigation. The microanalytical techniques employed during this research include: energy dispersive x-ray spectroscopy (EDS) using both conventional and scanning transmission electron microscopy (CTEM, STEM), transmission scanning electron diffraction (TSED), the stationary diffraction pattern technique, and electron energy loss spectroscopy (ELS) using a dedicated scanning transmission electron microscope

  8. Follicle and oocyte growth in early postnatal calves: cytochemical, autoradiographical and electron microscopical studies

    International Nuclear Information System (INIS)

    Mhawi, A.J.; Kaňka, J.; Motlík, J.

    1991-01-01

    The initiation of oocyte and follicle growth was studied in 1- and 3-d-old calf ovaries using cytochemical, autoradiographical and electron microscopical approaches. Attention was only paid to unilaminar ovarian follicles that were classified into 3 categories: unilaminar flattened (UF), unilaminar flatto-cuboidal (UFC) and unilaminar cuboidal (UC) ovarian follicles when the oocyte was surrounded by 1 layer of flattened, a mixture of flattened and cuboidal and entirely cuboidal follicle cells, respectively. Our findings suggested that oocytes within each of these follicle categories were in different developmental stages. Furthermore, electron microscopic observations revealed that early after birth, oocyte nuclei characteristic of diplotene configuration (aggregation of the nuclear chromatin into moderately electron-dense small patches and fibrillo-granular texture of the nucleolus) were encountered in 41% of the UF follicles. The rest of the UF as well as all of the UFC and UC follicles were found to contain dictyate oocytes in which the chromatin was highly decondensed and the nucleolus differentiated into fibrillar, fibrillo-granular and granular components. The present results also indicated that the complete transition of the surrounding follicle cells from flattened to cuboidal shape and the morphological changes of the oocyte endoplasmic reticulum and mitochondria were 2 complementary events essential for initiation of oocyte growth

  9. Electron Microscopic Changes of Rabbit Retina after Chromovitrectomy Using Combined Dyes (Experimental Study

    Directory of Open Access Journals (Sweden)

    B. M. Aznabaev

    2018-01-01

    Full Text Available Purpose: to evaluate on experimental model electron-microscopic changes of rabbit retina after staining of the posterior eye segmentwith combined dyes based on Trypan blue and Brilliant blue G for the assessment of their safety. Methods. The study was performed onChinchilla breed rabbits. Combined dyes based on Trypan blue and Brilliant blue were used: MembraneBlue-Dual (DORC, Netherlandsand “Staining solution for ophthalmic surgery” (JCS “Optimedservis”, Russia. Standard three-port vitrectomy technique was used. After vitreous removal dyes were injected in vitreous cavity and exposed for 10 seconds and then removed. The vitreous cavity was filled by a balanced salt solution. An electron-microscopic evaluation was performed on 5, 14 and 30 days after surgery. Eyes were enucleated in 20 minutes after animal was killed by air embolization. Intact eyes were used as a control, all samples were prepared in same сonditions. The damage of the retina architectonics and the presence of intracellular inclusions were evaluated. Results. The staged character of pathomorphological changes was revealed. On the 5th day moderate edema and hydropic dystrophy of neurons were registered. On the 14th day, there was no negative dynamics. On day 30, the signs of edema and dystrophy of neurons practically disappeared, which may indicate a fundamental reversibility of the registered changes. Conclusion. Investigated dyes for staining intraocular structures based on Trypan blue and Brilliant blue did not cause significant histomorphological changes and toxic effects on retinal cell structures. Detected electron microscopic changes were insignificant, had reversible character and could be mostly caused by a surgical injury.

  10. The reactions of loaded carbon nanotubes, studied by novel electron microscope techniques

    International Nuclear Information System (INIS)

    Rawcliffe, A.

    1999-01-01

    A novel electron microscope technique, controlled environment transmission electron microscopy (CETEM), has been used to investigate the reaction of materials loaded within the internal cavities of carbon nanotubes. CETEM allows the introduction of up to 20 mbar of gas around an electron microscope sample, while maintaining a high resolution imaging capability. The microscope is stable, flexible and reliable under these conditions and high resolution images of encapsulated transmission metal oxide reduction have been recorded at 460 deg. C. Recently discovered carbon nanotubes have in theory many applications, many of which will require controlled reliable loading of the internal cavity. However, at present, there is little experimental evidence to confirm theoretical descriptions of the fundamental mechanisms which govern both the extent of loading and the state in which it is found. Similarly, reaction within the cavity and the effect of encapsulation on the nano-scale particle distribution must also be understood, and CETEM proves to be an ideal technique for the study of these processes. Nanotubes have been loaded from aqueous solution with (NH 4 ) 2 IrCI 6 and with molten MoO 3 or K 2 WO 4 /WO 3 . Bulk samples of the first salt are known to decompose spontaneously in air at 200 deg. C, and the bulk oxides are partially reduced at temperature under hydrogen to give potentially useful conducting phases. Comparing the reaction of these materials it is thus possible to: investigate the effect of loading on their reaction; compare the reaction of these materials in- and out-side the tube cavity; and assess the result of violent loading processes on the tubes themselves. Fortuitously, a spontaneous decomposition, a solid-gas reduction and a phase rearrangement were all recorded, allowing mechanistic implications of encapsulation to be considered for each of these reactions. Perhaps surprisingly, the results can be largely interpreted using the reported bulk

  11. Electron Microscope Center Opens at Berkeley.

    Science.gov (United States)

    Robinson, Arthur L.

    1981-01-01

    A 1.5-MeV High Voltage Electron Microscope has been installed at the Lawrence Berkeley Laboratory which will help materials scientists and biologists study samples in more true-to-life situations. A 1-MeV Atomic Resolution Microscope will be installed at the same location in two years which will allow scientists to distinguish atoms. (DS)

  12. Scanning Electron Microscopic Studies of the Pecten Oculi in the Quail (Coturnix coturnix japonica

    Directory of Open Access Journals (Sweden)

    Aris F. Pourlis

    2013-01-01

    Full Text Available The main purpose of this study is to extend the microscopic investigations of the pecten oculi in the quail in order to add some information on the unresolved functional anatomy of this unique avian organ. The pecten oculi of the quail was studied by scanning electron microscopy. Eighteen- to-twenty two highly vascularised accordion-like folds were joined apically by a heavily pigmented bridge of tissue, which holds the pecten in a fanlike shape, widest at the base. The structure of the double layered limiting membrane was recorded. The presence of hyalocytes with macrophage-like appearance was illustrated. It is assumed that the pecten oculi of the quail resembles that of the chicken. Illustrated morphological features of this species may add information on the active physiological role of the pecten. But still, the functional significance of this organ is a matter of controversies.

  13. Uptake and processing of [3H]retinoids in rat liver studied by electron microscopic autoradiography

    International Nuclear Information System (INIS)

    Hendriks, H.F.; Elhanany, E.; Brouwer, A.; de Leeuw, A.M.; Knook, D.L.

    1988-01-01

    The role of rat liver cell organelles in retinoid uptake and processing was studied by electron microscopic autoradiography. [ 3 H]Retinoids were administered either orally, to make an inventory of the cell organelles involved, or intravenously as chylomicron remnant constituents to study retinoid processing by the liver with time. No qualitative differences were observed between the two routes of administration. Time-related changes in the distribution of grains were studied using chylomicron remnant [ 3 H]retinoids. The percentages of grains observed over cells and the space of Disse at 5 and 30 min after administration were, respectively: parenchymal cells, 72.6 and 70.4%; fat-storing cells, 5.0 and 18.1%, and the space of Disse, 14.4 and 8.9%. Low numbers of grains were observed over endothelial and Kupffer cells. The percentages of grains observed over parenchymal cell organelles were, respectively: sinusoidal area, 59.6 and 34.4%; smooth endoplasmic reticulum associated with glycogen, 13.8 and 13.4%; mitochondria, 5.4 and 13.6%; rough endoplasmic reticulum, 4.2 and 7.3%, and rough endoplasmic reticulum associated with mitochondria, 3.7 and 6.5%. It is concluded that chylomicron remnant [ 3 H]retinoids in combination with electron microscopic autoradiography provide a good system to study the liver processing of retinoids in vivo. These results, obtained in the intact liver under physiological conditions, further substantiate that retinoids are processed through parenchymal cells before storage occurs in fat-storing cell lipid droplets, that retinoid uptake is not mediated through lysosomes and that the endoplasmic reticulum is a major organelle in retinoid processing

  14. The nervus terminalis in the mouse: light and electron microscopic immunocytochemical studies.

    Science.gov (United States)

    Jennes, L

    1987-01-01

    The distribution of gonadotropin-releasing hormone (GnRH)-containing neurons and fibers in the olfactory bulb was studied with light and electron microscopic immunohistochemistry in combination with retrograde transport of "True Blue" and horseradish peroxidase and lesion experiments. GnRH-positive neurons are found in the septal roots of the nervus terminalis, in the ganglion terminale, intrafascicularly throughout the nervus terminalis, in a dorso-ventral band in the caudal olfactory bulb, in various layers of the main and accessory olfactory bulb, and in the basal aspects of the nasal epithelium. Electron microscopic studies show that the nerve fibers in the nervus terminalis are not myelinated and are not surrounded by Schwann cell sheaths. In the ganglion terminale, "smooth" GnRH neurons are seen in juxtaposition to immunonegative neurons. Occasionally, axosomatic specializations are found in the ganglion terminale, but such synaptic contacts are not seen intrafascicularly in the nervus terminalis. Retrograde transport studies indicate that certain GnRH neurons in the septal roots of the nervus terminalis were linked to the amygdala. In addition, a subpopulation of nervus terminalis-related GnRH neurons has access to fenestrated capillaries whereas other GnRH neurons terminate at the nasal epithelium. Lesions of the nervus terminalis caudal to the ganglion terminale result in sprouting of GnRH fibers at both sites of the knife cut. The results suggest that GnRH in the olfactory system of the mouse can influence a variety of target sites either via the blood stream, via the external cerebrospinal fluid or via synaptic/asynaptic contacts with, for example, the receptor cells in the nasal mucosa.

  15. Accumulation of fission fragment 147Pm in subcellular level studied by electron microscopic autoradiography

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Wang Yuanchang

    1990-11-01

    The subcellular localization of fission fragment 147 Pm in tissue cells by electron microscopic autoradiography was investigated. The early harm of internal contaminated accumulation of 147 Pm appeared in blood cells and endothelium cells, obviously in erythrocytes. Then 147 Pm was selectively deposited in ultrastructure of liver cells. Autoradiographic study demonstrated that dense tracks appeared in mitochondria and lysosome of podal cells within renal corpuscle. In nucleus as well as in mitochondria and microbodies of epicyte of kidney near-convoluted tubule, there are numerous radioactive 149 Pm accumulated. With the prolongation of observing time, 149 Pm was selectively and steadily deposited in subcellular level of organic component bone. The radionuclides could be accumulated in nucleus of osteoclasts and osteoblasts. In organelles, the radionuclides was mainly accumulated in rough endoplasmic reticulum and mitochondria. Autoradiographic tracks of 149 Pm was obviously found to be localized in combined point between Golgi complex and transitive vesicle of rough endoplasmic reticulum

  16. Scanning Electron Microscopic Studies of Microwave Sintered Al-SiC Nanocomposites and Their Properties

    Directory of Open Access Journals (Sweden)

    M. A. Himyan

    2018-01-01

    Full Text Available Al-metal matrix composites (AMMCs reinforced with diverse volume fraction of SiC nanoparticles were synthesized using microwave sintering process. The effects of the reinforcing SiC particles on physical, microstructure, mechanical, and electrical properties were studied. The phase, microstructural, and surface analyses of the composites were systematically conducted using X-ray diffraction (XRD, scanning electron microscope (SEM, and surface profilometer techniques, respectively. The microstructural examination revealed the homogeneous distribution of SiC particles in the Al matrix. Microhardness and compressive strength of nanocomposites were found to be increasing with the increasing volume fraction of SiC particles. Electrical conductivity of the nanocomposites decreases with increasing the SiC content.

  17. Electron microscope autoradiographic studies of the erythroblasts of a case of congenital dyserythropoietic anaemia, type II

    Energy Technology Data Exchange (ETDEWEB)

    Wickramasinghe, S N [Saint Mary' s Hospital Medical School, London (UK); Parry, T E [Department of Haematology, Llandough Hospital, Penarth, Glamorgan, Wales; Hughes, M [Division of Experimental Pathology, The Mathilda and Terence Kennedy Institute of Rheumatology, Bute Gardens, London, England

    1978-01-01

    The bone marrow cells of a patient with congenital dyserythropoietic anaemia, type II, were incubated with /sup 3/H-thymidine /sup 3/H-uridine or /sup 3/H-leucine for 1 h and studied using the technique of electron microscope autoradiography. Several of the erythroblasts which either displayed the characteristic subsurface double membranes or showed various non-specific abnormalities of the nuclear membrane were found to be actively engaged in DNA, RNA and protein synthesis. Both members of some pairs of erythroblasts which were joined together by a spindle bridge were found to be engaged in DNA synthesis, indicating that some spindle bridges persist for a period longer than the duration of the G/sub 1/ phase. A small proportion of mononucleate and binucleate late (non-dividing) erythroblasts showed a marked depression or arrest of protein synthesis and some or all of such cells were presumably destined to be phagocytosed by the bone marrow macrophages.

  18. Structural and functional changes in the intenstine of irradiated and hypothermic irradiated rats : a scanning and transmission electron microscopic study

    International Nuclear Information System (INIS)

    Chaudhuri, S.; Chaudhuri, Swapna; Roy, Bijon

    1982-01-01

    Severe destructive changes in the intestine of rats following whole body exposure to gamma rays (832 rads) were observed by light microscope, scanning and transmission electron microscope studies. Hypothermia (15deg C rectal temperature) induced prior to irradiation protected the intestinal mucosa from destruction. A simultaneous study showed that glucose absorption decreased significantly in irradiated rats, whereas it was increased in hypothermic irradiated animals. (author)

  19. Electron microscope studies. Progress report, 1 July 1964--1 June 1992

    Energy Technology Data Exchange (ETDEWEB)

    Crewe, A.V.; Kapp, O.H.

    1992-07-01

    This is a report covering the research performed in the Crewe laboratory between 1964 and 1992. Because of limitations of space we have provided relatively brief summaries of the major research directions of the facility during these years. A complete bibliography has been included and we have referenced groups of pertinent publications at the beginning of each section. This report summarizes our efforts to develop better electron microscopes and chronicles many of the experimental programs, in materials science and biology, that acted both as a stimulus to better microscope design and also as a testing ground for many instrumental innovations.

  20. Ultrastructural alterations in ciliary cells exposed to ionizing radiation. A scanning and transmission electron microscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Baldetorp, L; Mecklenburg, C v; Haakansson, C H [Lund Univ. (Sweden). Hospital; Lund Univ. (Sweden). Dept. of Zoology)

    1977-01-01

    Early effects of ionizing radiation were investigated in an experimental in vitro system using the ciliary cells of the tracheal mucous membrane of the rabbit, irradiated at 30/sup 0/C and at more than 90% humidity. The changes in physiological activities of the ciliary cells caused by irradation were continously registered during the irradation. The specimens were examined immediately after irradiation electron microscopically. The morphological changes in irradiated material after 10-70 Gy are compared with normal material. After 40-70 Gy, scanning electron microscopy revealed the formation of vesicles on cilia, and club-like protrusions and adhesion of their tips. After 30-70 Gy, a swelling of mitochondrial membranes and cristae was apparent transmission electron microscopically. The membrane alterations caused by irradiation are assumed to disturb the permeability and flow of ATP from the mitochondria, which in turn leads to the recorded changes in the activity of the ciliated cells.

  1. Kidney lesions in Rocky Mountain spotted fever: a light-, immunofluorescence-, and electron-microscopic study.

    Science.gov (United States)

    Bradford, W. D.; Croker, B. P.; Tisher, C. C.

    1979-01-01

    The essential pathologic lesion in Rocky Mountain spotted fever (RMSF) is a vasculitis that may involve the kidneys as well as the heart, brain, skin, and subcutaneous tissues. Histopathologic information concerning the response of the kidneys in RMSF is rather limited, however. In this study renal tissue from 17 children who died of RMSF was examined by light, electron, and immunofluorescence microscopy. A lymphocytic or mixed inflammation, or both, involving vessels and interstitium of the kidney was found in all patients. In addition, 10 patients had histologic evidence of acute tubular necrosis, and another 3 had glomerular lesions consisting of focal segmental tuft necrosis or increased cellularity secondary to neutophilic infiltration, or both. Immunofluorescence- and electron-microscopic studies failed to demonstrate immune-complex deposition within glomeruli, a finding that suggests that immunoglobulin and classic immune complexes were not involved in the pathogenesis of the renal lesions at the time of death. These findings suggest the possibility that the pathogenesis of the renal lesion in RMSF may be due to a direct action of the organism (Rickettsia rickettsii) on the vessel wall. Images Figure 2 Figure 1 PMID:525676

  2. Transmission electron microscopic study of pyrochlore to defect-fluorite transition in rare-earth pyrohafnates

    Energy Technology Data Exchange (ETDEWEB)

    Karthik, Chinnathambi, E-mail: Karthikchinnathambi@boisestate.edu [Department of Materials Science and Engineering, Boise State University, 1910 University drive, Boise, ID 83725 (United States); Center for Advanced Energy Studies, 995 University Blvd, Idaho Falls, ID 83415 (United States); Anderson, Thomas J. [Department of Materials Science and Engineering, Boise State University, 1910 University drive, Boise, ID 83725 (United States); Gout, Delphine [Oak Ridge National Lab, Neutron Scattering Science Division, Oak Ridge, TN (United States); Ubic, Rick [Department of Materials Science and Engineering, Boise State University, 1910 University drive, Boise, ID 83725 (United States); Center for Advanced Energy Studies, 995 University Blvd, Idaho Falls, ID 83415 (United States)

    2012-10-15

    A structural transition in rare earth pyrohafnates, Ln{sub 2}Hf{sub 2}O{sub 7} (Ln=Y, La, Pr, Nd, Tb, Dy, Yb and Lu), has been identified. Neutron diffraction showed that the structure transforms from well-ordered pyrochloric to fully fluoritic through the lanthanide series from La to Lu with a corresponding increase in the position parameter x of the 48f (Fd3{sup Macron }m) oxygen site from 0.330 to 0.375. As evidenced by the selected area electron diffraction, La{sub 2}Hf{sub 2}O{sub 7}, Pr{sub 2}Hf{sub 2}O{sub 7} and Nd{sub 2}Hf{sub 2}O{sub 7} exhibited a well-ordered pyrocholoric structure with the presence of intense superlattice spots, which became weak and diffuse (in Dy{sub 2}Hf{sub 2}O{sub 7} and Tb{sub 2}Hf{sub 2}O{sub 7}) before disappearing completely as the series progressed towards the Lu end. High resolution electron microscopic studies showed the breakdown of the pyrochlore ordering in the form of antiphase domains resulting in diffused smoke-like superlattice spots in the case of Dy{sub 2}Hf{sub 2}O{sub 7} and Tb{sub 2}Hf{sub 2}O{sub 7}. - Graphical abstract: Transmission electron microscopic studies showed the ordered pyrochlore to defect fluorite transition in rare-earth pyrohafnates to occur via the formation of anti-phase domains to start with. Highlights: Black-Right-Pointing-Pointer Pyrochlore to fluorite structural transition in rare earth pyrohafnates. Black-Right-Pointing-Pointer La{sub 2}Hf{sub 2}O{sub 7}, Pr{sub 2}Hf{sub 2}O{sub 7} and Nd{sub 2}Hf{sub 2}O{sub 7} showed well ordered pyrochlore structure. Black-Right-Pointing-Pointer Short range ordering in Dy{sub 2}Hf{sub 2}O{sub 7} and Tb{sub 2}Hf{sub 2}O{sub 7}. Black-Right-Pointing-Pointer Break down of pyrochlore ordering due to antiphase boundaries. Black-Right-Pointing-Pointer Rest of the series showed fluoritic structure.

  3. Transmission electron microscopical study of teenage crown dentin on the nanometer scale

    Energy Technology Data Exchange (ETDEWEB)

    Panfilov, Peter, E-mail: peter.panfilov@urfu.ru [Ural Federal University, Ekaterinburg (Russian Federation); Kabanova, Anna [Ural Federal University, Ekaterinburg (Russian Federation); Guo, Jinming; Zhang, Zaoli [Erich Schmid Institute for Materials Science, Austrian Academy of Sciences, Leoben (Austria)

    2017-02-01

    Statement of significance: This is the first transmission electron microscopic study of teenage crown dentin on the nanometer scale. Samples for TEM were prepared by mechanical thinning and chemical polishing that allowed obtaining the electron transparent foils. It was firstly shown that human dentin possesses the layered morphology: the layers are oriented normally to the main axis of a tooth and have the thickness of ~ 50 nm. HA inorganic phase of teenage crown dentin is in the amorphous state. The cellular structure, which was formed from collagen fibers (diameter is ~ 5 nm), are observed near DEJ region in teenage dentin, whereas bioorganic phase of teenage crown dentin near the pulp camera does not contain the collagen fibers. Cracks in dentin thin foils have sharp tips, but big angles of opening (~ 30{sup °}) with plastic zone ahead crack tip. It means that young crown human dentin exhibits ductile or viscous-elastic fracture behavior on the nanometer scale. - Highlights: • Dentin has layered morphology. • Mineral component of dentin is in amorphous state. • Collagen fibers form cellular structure in dentin. • Cracks in dentin behave by elastic-plastic manner.

  4. Transmission electron microscopical study of teenage crown dentin on the nanometer scale

    International Nuclear Information System (INIS)

    Panfilov, Peter; Kabanova, Anna; Guo, Jinming; Zhang, Zaoli

    2017-01-01

    Statement of significance: This is the first transmission electron microscopic study of teenage crown dentin on the nanometer scale. Samples for TEM were prepared by mechanical thinning and chemical polishing that allowed obtaining the electron transparent foils. It was firstly shown that human dentin possesses the layered morphology: the layers are oriented normally to the main axis of a tooth and have the thickness of ~ 50 nm. HA inorganic phase of teenage crown dentin is in the amorphous state. The cellular structure, which was formed from collagen fibers (diameter is ~ 5 nm), are observed near DEJ region in teenage dentin, whereas bioorganic phase of teenage crown dentin near the pulp camera does not contain the collagen fibers. Cracks in dentin thin foils have sharp tips, but big angles of opening (~ 30 ° ) with plastic zone ahead crack tip. It means that young crown human dentin exhibits ductile or viscous-elastic fracture behavior on the nanometer scale. - Highlights: • Dentin has layered morphology. • Mineral component of dentin is in amorphous state. • Collagen fibers form cellular structure in dentin. • Cracks in dentin behave by elastic-plastic manner.

  5. High resolution transmission electron microscopic study of nanoporous carbon consisting of curved single graphite sheets

    International Nuclear Information System (INIS)

    Bourgeois, L.N.; Bursill, L.A.

    1997-01-01

    A high resolution transmission electron microscopic study of a nanoporous carbon rich in curved graphite monolayers is presented. Observations of very thin regions. including the effect of tilting the specimen with respect to the electron beam, are reported. The initiation of single sheet material on an oriented graphite substrate is also observed. When combined with image simulations and independent measurements of the density (1.37g cm -3 ) and sp 3 /sp 2 +sp 2 bonding fraction (0.16), these observations suggest that this material is a two phase mixture containing a relatively low density aggregation of essentially capped single shells like squat nanotubes and polyhedra, plus a relatively dense 'amorphous' carbon structure which may be described using a random-Schwarzite model. Some negatively-curved sheets were also identified in the low density phase. Finally, some discussion is offered regarding the growth mechanisms responsible for this nanoporous carbon and its relationship with the structures of amorphous carbons across a broad range of densities, porosities and sp 3 /sp 2 +sp 3 bonding fractions

  6. Spectral Interferometry with Electron Microscopes

    Science.gov (United States)

    Talebi, Nahid

    2016-01-01

    Interference patterns are not only a defining characteristic of waves, but also have several applications; characterization of coherent processes and holography. Spatial holography with electron waves, has paved the way towards space-resolved characterization of magnetic domains and electrostatic potentials with angstrom spatial resolution. Another impetus in electron microscopy has been introduced by ultrafast electron microscopy which uses pulses of sub-picosecond durations for probing a laser induced excitation of the sample. However, attosecond temporal resolution has not yet been reported, merely due to the statistical distribution of arrival times of electrons at the sample, with respect to the laser time reference. This is however, the very time resolution which will be needed for performing time-frequency analysis. These difficulties are addressed here by proposing a new methodology to improve the synchronization between electron and optical excitations through introducing an efficient electron-driven photon source. We use focused transition radiation of the electron as a pump for the sample. Due to the nature of transition radiation, the process is coherent. This technique allows us to perform spectral interferometry with electron microscopes, with applications in retrieving the phase of electron-induced polarizations and reconstructing dynamics of the induced vector potential. PMID:27649932

  7. Topographic Features of Five K-file Brands in Iranian Market: A Scanning Electron Microscopic Study.

    Science.gov (United States)

    Shahravan, Arash; Gorjestani, Hedayat; Izadi, Arash; Mortazavi, Nazanin

    2018-01-01

    Endodontic files which are used to clean and shape the root canal space differ from each other regarding technical specifications. Recently, K-type files are repeatedly studied on their cutting efficiency. This study aims to evaluate the tip design and cutting efficiency of 5 brands of K-files, available in Iran dental market (naming Dentsply, Thomas, Mani, Perfect and Larmrose). In this descriptive study, topographic features of file tips were investigated by the scanning electron microscope (SEM). Those features included tip symmetry, tip design, tip angle, and the distance from the tip to the lowest flute. SEM images (×250 magnification) of files were prepared. Statistical tests (Fisher's exact test, Chi -square, ANOVA, and t test) were used and P brands. No significant differences were found with respect to distance from the file tip to the lowermost flute between different file brands of this study ( P =0.2, One way ANOVA). Dentsply and Mani files possessed the most symmetrical tips and greatest tip angles. With respect to tip length, all 5 brands were satisfactory. However, neither of 5 brands evaluated topographically were outstanding in every aspect.

  8. Vibrational spectroscopy in the electron microscope.

    Science.gov (United States)

    Krivanek, Ondrej L; Lovejoy, Tracy C; Dellby, Niklas; Aoki, Toshihiro; Carpenter, R W; Rez, Peter; Soignard, Emmanuel; Zhu, Jiangtao; Batson, Philip E; Lagos, Maureen J; Egerton, Ray F; Crozier, Peter A

    2014-10-09

    Vibrational spectroscopies using infrared radiation, Raman scattering, neutrons, low-energy electrons and inelastic electron tunnelling are powerful techniques that can analyse bonding arrangements, identify chemical compounds and probe many other important properties of materials. The spatial resolution of these spectroscopies is typically one micrometre or more, although it can reach a few tens of nanometres or even a few ångströms when enhanced by the presence of a sharp metallic tip. If vibrational spectroscopy could be combined with the spatial resolution and flexibility of the transmission electron microscope, it would open up the study of vibrational modes in many different types of nanostructures. Unfortunately, the energy resolution of electron energy loss spectroscopy performed in the electron microscope has until now been too poor to allow such a combination. Recent developments that have improved the attainable energy resolution of electron energy loss spectroscopy in a scanning transmission electron microscope to around ten millielectronvolts now allow vibrational spectroscopy to be carried out in the electron microscope. Here we describe the innovations responsible for the progress, and present examples of applications in inorganic and organic materials, including the detection of hydrogen. We also demonstrate that the vibrational signal has both high- and low-spatial-resolution components, that the first component can be used to map vibrational features at nanometre-level resolution, and that the second component can be used for analysis carried out with the beam positioned just outside the sample--that is, for 'aloof' spectroscopy that largely avoids radiation damage.

  9. Transmission electron-microscopic studies of structural changes in polycrystalline graphite after high temperature irradiation

    International Nuclear Information System (INIS)

    Platonov, P.A.; Gurovich, B.A.; Shtrombakh, Ya.I.; Karpukhin, V.I.

    1985-01-01

    Transmission electron-microscopic investigation of polycrystalline graphite before and after irradiation is carried out. The direct use of graphite samples after ion thinning, as an inquiry subject is the basic peculiarity of the work. Main structural components of MPG-6 graphite before and after irradiation are revealed, the structural mechanism of the reactor graphite destruction under irradiation is demonstrated. The mean values of L αm and L cm crystallite dimensions are determined. Radiation defects, occuring in some crystallites after irradiation are revealed by the dark-field electron microscopy method

  10. Scanning electron microscope studies of adsorption and crystal growth on tungsten

    International Nuclear Information System (INIS)

    Akhter, P.

    1980-03-01

    An ultra high vacuum scanning electron microscope (UHV-SEM), equipped with additional surface science techniques (AES, RHEED, work function), has been used to study the adsorption and growth of Cs and Ag on polycrystalline and (110) single crystal of W. These are used to study the layer plus island, or Stranski-Krastanov growth mode. The technique and apparatus are described. In the temperature range of 15 0 C, a whole variety of growth phenomena in the system Ag/W(110) has been seen by SEM. Two intermediate layers are followed by island growth, except at T > approximately equal to 500 0 C where island growth starts at a lower coverage. At T 0 C, layer-like growth is deduced from both AES and SEM measurements. The forms, crystallographic orientations and nucleation densities of islands have been explored in detail using a combination of SEM, AES and EBSP techniques. AES results at room temperature and at 500 0 C have been analysed and the results fit very well with SEM observations. A growth model for Ag/W(110) has been presented and atomistic nucleation theory has been extended, to understand the Stranski-Krastanov growth mode in general and the Ag/W(110) results in particular. (author)

  11. Somatic Embryos in Catharanthus roseus: A Scanning Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Junaid ASLAM

    2014-06-01

    Full Text Available Catharanthus roseus (L. G. Don is an important medicinal plant as it contains several anti-cancerous compounds, like vinblastine and vincristine. Plant tissue culture technology (organogenesis and embryogenesis has currently been used in fast mass propagating raw materials for secondary metabolite synthesis. In this present communication, scanning electron microscopic (SEM study of somatic embryos was conducted and discussed. The embryogenic callus was first induced from hypocotyls of in vitro germinated seeds on which somatic embryos, differentiated in numbers, particularly on 2,4-D (1.0 mg/L Murashige and Skoog (MS was medium. To understand more about the regeneration method and in vitro formed embryos SEM was performed. The SEM study revealed normal somatic embryo origin and development from globular to heart-, torpedo- and then into cotyledonary-stage of embryos. At early stage, the embryos were clustered together in a callus mass and could not easily be detached from the parental tissue. The embryos were often long cylindrical structure with or without typical notch at the tip. Secondary embryos were also formed on primary embryo structure. The advanced cotyledonary embryos showed prominent roots and shoot axis, which germinated into plantlets. The morphology, structure and other details of somatic embryos at various stages were presented.

  12. Electron microscopic radioautographic studies on macromolecular synthesis in mitochondria of animal cells in aging

    International Nuclear Information System (INIS)

    Nagata, Tetsuji

    2010-01-01

    Study aging changes of intramitochondrial DNA, RNA, protein synthesis of mouse organs during the development and aging, 30 groups of developing and aging mice (3 individuals each), from fetal day 19 to postnatal newborn at day 1, 3, 9, 14 and adult at month 1, 2, 6, 12 to 24, were injected with either 3 H-thymidine, 3 H-uriidine, or 3 H-leucine, sacrificed 1 h later and liver, adrenal, lung and testis tissues observed by electron microscopic radioautography. Accordingly, numbers of mitochondria per cell profile area, numbers of labeled mitochondria and the mitochondrial labeling index labeled with 3 H-labeled precursors showing DNA, RNA, protein synthesis in these cells (hepatocytes, 3 zones of the adrenal cortices - zona glomerulosa, fasciculata and reticularis -, adrenal medullary cells, pulmonary cells and testis cells) were counted per cells and compared among the respective developing and aging groups. The numbers of mitochondria in these cells increased from fetal day 19 to postnatal month 1 and 2. However, the numbers of labeled mitochondria and the labeling indices of intramitochondrial DNA, RNA, protein syntheses incorporating the 3 H-labeled precursors in the described tissue cells increased from fetal day 19 to postnatal month 1 and decreased to month 24. These data support that the activity of intramitochnodrial DNA, RNA, protein syntheses in cells of these tissues increased and decreased by development and aging in mice. The intramitochondrial DNA, RNA and protein syntheses in some other organs were also reviewed and discussed. (author)

  13. Electron microscopic radioautographic studies on macromolecular synthesis in mitochondria of animal cells in aging

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Tetsuji, E-mail: nagata@kowagakuen.ac.j [Shinshu Univ. School of Medicine, Matsumoto (Japan). Dept. of Anatomy and Cell Biology

    2010-07-01

    Study aging changes of intramitochondrial DNA, RNA, protein synthesis of mouse organs during the development and aging, 30 groups of developing and aging mice (3 individuals each), from fetal day 19 to postnatal newborn at day 1, 3, 9, 14 and adult at month 1, 2, 6, 12 to 24, were injected with either {sup 3}H-thymidine, {sup 3}H-uriidine, or {sup 3}H-leucine, sacrificed 1 h later and liver, adrenal, lung and testis tissues observed by electron microscopic radioautography. Accordingly, numbers of mitochondria per cell profile area, numbers of labeled mitochondria and the mitochondrial labeling index labeled with {sup 3}H-labeled precursors showing DNA, RNA, protein synthesis in these cells (hepatocytes, 3 zones of the adrenal cortices - zona glomerulosa, fasciculata and reticularis -, adrenal medullary cells, pulmonary cells and testis cells) were counted per cells and compared among the respective developing and aging groups. The numbers of mitochondria in these cells increased from fetal day 19 to postnatal month 1 and 2. However, the numbers of labeled mitochondria and the labeling indices of intramitochondrial DNA, RNA, protein syntheses incorporating the {sup 3}H-labeled precursors in the described tissue cells increased from fetal day 19 to postnatal month 1 and decreased to month 24. These data support that the activity of intramitochnodrial DNA, RNA, protein syntheses in cells of these tissues increased and decreased by development and aging in mice. The intramitochondrial DNA, RNA and protein syntheses in some other organs were also reviewed and discussed. (author)

  14. Electron microscopic studies on ameloblast using /sup 45/Ca as tracer

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, K [Gifu Univ. (Japan). Faculty of Medicine

    1974-02-01

    In order to study the functional role of ameloblast on inorganic substance, electron microscopic autoradiography was prepared from dental germ of incisor and molar teeth of young rats using /sup 45/Ca as the tracer and following results were obtained. At 15 minutes after /sup 45/Ca administration, /sup 45/Ca appeared in cells of each stage of development, reaching the peak after 30 minutes and gradually shifting from the inside of cells to matrix. /sup 45/Ca was localized in the cells in the nuclear substance, rough surfaced endoplasmic reticulum, Golgi area and mitochondria. Especially in the mitochondria, silver grains are accumulated in high concentration, suggesting a major role in the storage and accumulation of Ca. /sup 45/Ca passed through the mature ameloblasts rapidly. After 15 minutes, silver grains were noted in the matrix formation. After 2 hours, scarcely any silver grains were noted in the cells, most of them being shifted to calcifing area from the matrix formation. As the pathway of transport of /sup 45/Ca, intracellular passage is mainly adopted in the stage of matrix formation, without transport through the intercellular space. Even if a considerable separation occurred between each cell in the mature stage, no silver grains were noted in this area. These results would indicate an important role of ameloblast in the transport and storage of inorganic substances through the movement of Ca.

  15. Electron microscope study of irradiated beryllium oxide; Etude au microscope electronique de l'oxyde de beryllium irradie

    Energy Technology Data Exchange (ETDEWEB)

    Bisson, A A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    The beryllium oxide is studied first by fractography, before and after irradiation, using sintered samples. The fractures are examined under different aspects. The higher density sintered samples, with transgranular fractures are the most interesting for a microscopic study. It is possible to mark the difference between the 'pores' left by the sintering process and the 'bubbles' of gases that can be produced by former thermal treatments. After irradiation, the grain boundaries are very much weakened. By annealing, it is possible to observe the evolution of the gases produced by the reaction (n, 2n) and (n. {alpha}) and gathered on the grain boundaries. The irradiated beryllium oxide is afterwards studied by transmission. For that, a simple method has been used: little chips of the crushed material are examined. Clusters of point defects produced by neutrons are thus detected in crystals irradiated at the three following doses: 6 x 10{sup 19}, 9 x 10{sup 19} and 2 x 10{sup 20} n{sub f} cm{sup -2} at a temperature below 100 deg. C. For the irradiation at 6 x 10{sup 19} n{sub f} cm{sup -2}, the defects are merely visible, but at 2 x l0{sup 20} n{sub f} cm{sup -2} the crystals an crowded with clusters and the Kikuchi lines have disappeared from the micro-diffraction diagrams. The evolution of the clusters into dislocation loops is studied by a series of annealings. The activation energy (0,37 eV) calculated from the annealing curves suggests that it must be interstitials that condense into dislocation loops. Samples irradiated at high temperatures (650, 900 and 1100 deg. C) are also studied. In those specimens the size of the loops is not the same as the equilibrium size obtained after out of pile annealing at the same temperature. Those former loops are more specifically studied and their Burgers vector is determined by micro-diffraction. (author) [French] L'oxyde de beryllium est d'abord etudie, par une methode fractographique, avant et apres irradiation, en

  16. Immunologic status of children with thyroid cancer living near Chernobyl (flow cytometric and electron microscopic study)

    International Nuclear Information System (INIS)

    Zak, K.P.; Gruzov, M.A.; Bolshova, B.V.; Afanasyeva, V.V.; Shlyakhovenko, V.S.; Vishnevskaya, O.A.; Tronko, N.D.

    1996-01-01

    It hag been carded out a light, election microscopic and flow cytometric study of blood leukocyte of children with malignant tumors (papillary carcinoma) of thyroid gland who were living at the moment of the accident near Chernobyl. The results obtained point out the presence of some disturbances of immune status of these children

  17. Scanning-electron-microscope study of normal-impingement erosion of ductile metals

    Science.gov (United States)

    Brainard, W. A.; Salik, J.

    1980-01-01

    Scanning electron microscopy was used to characterize the erosion of annealed copper and aluminum surfaces produced by both single- and multiple-particle impacts. Macroscopic 3.2 mm diameter steel balls and microscopic, brittle erodant particles were projected by a gas gun system so as to impact at normal incidence at speeds up to 140 m/sec. During the impacts by the brittle erodant particles, at lower speeds the erosion behavior was similar to that observed for the larger steel balls. At higher velocities, particle fragmentation and the subsequent cutting by the radial wash of debris created a marked change in the erosion mechanism.

  18. Electron holography study of magnetization behavior in the writer pole of a perpendicular magnetic recording head by a 1 MV transmission electron microscope.

    Science.gov (United States)

    Hirata, Kei; Ishida, Yoichi; Akashi, Tetsuya; Shindo, Daisuke; Tonomura, Akira

    2012-01-01

    The magnetic domain structure of the writer poles of perpendicular magnetic recording heads was studied using electron holography. Although the domain structure of a 100-nm-thick writer pole could be observed with a 300 kV transmission electron microscope, that of the 250-nm-thick writer pole could not be analyzed due to the limited transmission capability of the instrument. On the other hand, the detailed domain structure of the 250-nm-thick writer pole was successfully analyzed by a 1 MV electron microscope using its high transmission capability. The thickness and material dependency of the domain structure of a writer pole were discussed.

  19. The Titan Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal; Jinschek, Jörg R.

    2009-01-01

    University of Denmark (DTU) provides a unique combination of techniques for studying materials of interest to the catalytic as well as the electronics and other communities [5]. DTU’s ETEM is based on the FEI Titan platform providing ultrahigh microscope stability pushing the imaging resolution into the sub...

  20. Electron microscopic studies on odontoblasts using 45Ca as the tracer

    International Nuclear Information System (INIS)

    Okamoto, Eiji

    1980-01-01

    In order to study the relationship between odontoblasts and inorganic salts, odontoblasts of 10-day old rats' incisions and molars were used. The animals were sacrificed 15 minutes, 30 minutes, 1 hour or 2 hours after 45 Ca administration to obtain the specimen. The specimens were processed for electron microscopic autoradiography. 15 minutes after 45 Ca administration, silver grains indicated 45 Ca uptake was already noted within the cells. 45 Ca was localized in the mitochondria, Golgi area, rough surfaced endoplasmic reticulum and partially within the karyoplasm. After 30 minutes' administration, the number of silver grains were generally increased as compared with the findings obtained after 15 minutes' administration. The localization was similar with those after 15 minutes' administration but some were found in the ribosomes and smooth surfaced endoplasmic reticulum with numerous silver grains within small vesicles derived from the Golgi apparatus as well. A movement of 45 Ca from the protruding part to the stroma was also noted. 1 hour after the administration, the number of silver grains were generally decreased, with a more pronounced movement towards stroma from the protruding part. The marked movement of silver grains was obtained onto the collagen fibers in the stroma. In the mitochondria, however, considerable number of silver grains were still seen. In this section, on the other hand, numerous silver grains were seen in the intercellular space, in addition to the pathway of intracellular route, indicating the Ca shift from outside of the cells. After 2 hours' 45 Ca administration, the tendency towards the decrease of the silver grains became more remarkable, the movement of 45 Ca via the extracellular pathway described above was also frequently found. (author)

  1. Electron microscopic studies of the matrix formation of hard tissue organized cell

    International Nuclear Information System (INIS)

    Chou, Ching-Eng

    1982-01-01

    In order to study the functions of odontoblast, especially on the matrix formation, odontoblasts of rats' incisor and molar teeth were used. The animals were sacrificed 5 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours and 24 hours after 3 H-proline administration to obtain the specimen. The specimens were processed for electron microscopic autoradiography. The following results were obtained. 1. 5 minutes after 3 H-proline administration: Silver grains indicated 3 H-proline uptake were already noted within the cells and localized in the rough surfaced endoplasmic reticulum and surrounding ribosomes, partially within the karyoplasm. 2. 15 minutes after 3 H-proline administration: The number of silver grains were generally increased as compared with the findings obtained in 5 minutes. The localization moved to the Golgi apparatus and their surroundings. 3. 30 minutes after 3 H-proline administration: Silver grains obtained in Tome's fibers area and some in predentin. In this area granules derived from Golgi body were found. 4. 1 hour after 3 H-proline administration: The number of silver grains were generally decreased and more pronounced movement toward predentin, the marked movement of silver grains were obtained onto the collagen fibers and surroundings. 5. 2 hours after 3 H-proline administration: Silver grains moved to the calcified area and there collagen fibers became more remarkable. 6. 24 hours after 3 H-proline administration: No silver grains were founded in the odontoblast side but deposited in the predentin calcified area with stable condition. Based on the results of these observations, odontoblasts were shown to perform the function of synthesis, storage, transportation and control of collagen formation in addition to the role of matrix formation. (author)

  2. Development of Scanning Ultrafast Electron Microscope Capability.

    Energy Technology Data Exchange (ETDEWEB)

    Collins, Kimberlee Chiyoko [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Talin, Albert Alec [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Chandler, David W. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Michael, Joseph R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Modern semiconductor devices rely on the transport of minority charge carriers. Direct examination of minority carrier lifetimes in real devices with nanometer-scale features requires a measurement method with simultaneously high spatial and temporal resolutions. Achieving nanometer spatial resolutions at sub-nanosecond temporal resolution is possible with pump-probe methods that utilize electrons as probes. Recently, a stroboscopic scanning electron microscope was developed at Caltech, and used to study carrier transport across a Si p-n junction [ 1 , 2 , 3 ] . In this report, we detail our development of a prototype scanning ultrafast electron microscope system at Sandia National Laboratories based on the original Caltech design. This effort represents Sandia's first exploration into ultrafast electron microscopy.

  3. Design of a transmission electron positron microscope

    International Nuclear Information System (INIS)

    Doyama, Masao; Inoue, M.; Kogure, Y.; Hayashi, Y.; Yoshii, T.; Kurihara, T.; Tsuno, K.

    2003-01-01

    This paper reports the plans and design of positron-electron microscopes being built at KEK (High Energy Accelerator Research Organization), Tsukuba, Japan. A used electron microscope is altered. The kinetic energies of positrons produced by accelerators or by nuclear decays are not a unique value but show a spread over in a wide range. Positron beam is guided to a transmission electron microscope (JEM100SX). Positrons are moderated by a tungsten foil, are accelerated and are focused on a nickel sheet. The monochromatic focused beam is injected into an electron microscope. The focusing and aberration of positrons are the same as electrons in a magnetic system which are used in commercial electron microscopes. Imaging plates are used to record positron images for the transmission electron microscope. (author)

  4. [Ultrastructural organization of cytoplasmatic membrane of Anaerobacter polyendosporus studied by electron microscopic cryofractography].

    Science.gov (United States)

    Duda, V I; Suzina, N E; Dmitriev, V V

    2001-01-01

    Anaerobacter polyendosporus cells do not have typical mesosomes. However, the analysis of this anaerobic multispore bacterium by electron microscopic cryofractography showed that its cytoplasmic membrane contains specific intramembrane structures in the form of flat lamellar inverted lipid membranes tenths of nanometers to several microns in size. It was found that these structures are located in the hydrophobic interior between the outer and inner leaflets of the cytoplasmic membrane and do not contain intramembrane particles that are commonly present on freeze-fracture replicas. The flat inverted lipid membranes were revealed in bacterial cells cultivated under normal growth conditions, indicating the existence of a complex-type compartmentalization in biological membranes, which manifests itself in the formation of intramembrane compartments having the appearance of vesicles and inverted lipid membranes.

  5. Intravascular detection of Giardia trophozoites in naturally infected mice. An electron microscopic study.

    Science.gov (United States)

    el-Shewy, K A; Eid, R A

    2003-06-01

    During routine transmission electron microscopic (TEM) examination of mice naturally infected with Giardia muris, an intense infection with Giardia trophozoites was demonstrated within intestinal and renal tissues. Examination of randomly taken sections from these heavily infected tissues revealed marked deep affection with mixed pathology. Duodenal sections were found loaded with Giardia trophozoites in intimate contact with necrotic gut cells. Some of these trophozoites were detected within central lacteal of damaged villi and nearby blood vessels. Interestingly, and for the first time to be demonstrated, morphologically identical G. muris trophozoite was detected in a renal blood vessel. An intense cellular immune reaction was obviously demonstrated with remarkable interaction between giant macrophages and the trophozoites particulates. Involvement of deep tissues by Giardia trophozoites and their presence within vascular channels could open up questions about the possible invasive and disseminative behavior of G. muris, particularly in heavily and naturally infected hosts.

  6. Low temperature scanning electron microscopic studies on the interaction of globodera rostochiensis woll. and trichoderma harzianum rifai

    International Nuclear Information System (INIS)

    Saifullah, A.; Khan, N.U.

    2014-01-01

    Low temperature scanning electron microscopic (LTSEM) studies revealed that Trichoderma harzianum infected mature potato cysts nematode eggs by penetrating directly the cyst wall or via natural opening of mouth. Mycelial penetration on cyst wall or egg surface has been seen. The penetration of cyst wall or egg surface was either chemical or mechanical (directly or with appresorium) or both. Freeze fractionation showed the presence of mycelia inside the eggs. (author)

  7. Investigations in space-related molecular biology. [cryo-electron microscopic and diffraction studies on terrestrial and extraterrestrial specimens

    Science.gov (United States)

    Fernandez-Moran, H.; Pritzker, A. N.

    1974-01-01

    Improved instrumentation and preparation techniques for high resolution, high voltage cryo-electron microscopic and diffraction studies on terrestrial and extraterrestrial specimens are reported. Computer correlated ultrastructural and biochemical work on hydrated and dried cell membranes and related biological systems provided information on membrane organization, ice crystal formation and ordered water, RNA virus linked to cancer, lunar rock samples, and organometallic superconducting compounds. Apollo 11, 12, 14, and 15 specimens were analyzed

  8. Scanning electron microscopic (Sem studies on fourth instar larva and pupa of Anopheles (Cellia stephensi Liston (Anophelinae: Culicidae

    Directory of Open Access Journals (Sweden)

    Jagbir Singh Kirti

    2014-12-01

    Full Text Available Anopheles (Cellia stephensi Liston is a major vector species of malaria in Indian subcontinent. Taxonomists have worked on its various morphological aspects and immature stages to explore additional and new taxonomic attributes. Scanning electron microscopic (SEM studies have been conducted on the fourth instar larva and pupa of An. stephensi to find additional taxonomic features for the first time from Punjab state.

  9. Cell wall and DNA cosegregation in Bacillus subtilis studied by electron microscope autoradiography

    International Nuclear Information System (INIS)

    Schlaeppi, J.M.; Schaefer, O.; Karamata, D.

    1985-01-01

    Cells of a Bacillus subtilis mutant deficient in both major autolytic enzyme activities were continuously labeled in either cell wall or DNA or both cell wall and DNA. After appropriate periods of chase in minimal as well as in rich medium, thin sections of cells were autoradiographed and examined by electron microscopy. The resolution of the method was adequate to distinguish labeled DNA units from cell wall units. The latter, which could be easily identified, were shown to segregate symmetrically, suggesting a zonal mode of new wall insertion. DNA units could also be clearly recognized despite a limited fragmentation; they segregated asymmetrically with respect to the nearest septum. Analysis of cells simultaneously labeled in cell wall and DNA provided clear visual evidence of their regular but asymmetrical cosegregation, confirming a previous report obtained by light microscope autoradiography. In addition to labeled wall units, electron microscopy of thin sections of aligned cells has revealed fibrillar networks of wall material which are frequently associated with the cell surface. Most likely, these structures correspond to wall sloughed off by the turnover mechanism but not yet degraded to filterable or acid-soluble components

  10. Scanning Electron Microscope Analysis System

    Data.gov (United States)

    Federal Laboratory Consortium — This facility provides the capability to examine surfaces microscopically with high resolution (5 nanometers), perform micro chemical analyses of these surfaces, and...

  11. Electron microscopic radioautography of the cell

    International Nuclear Information System (INIS)

    Sarkisov, D.S.; Pal'tsyn, A.A.; Vtyurin, B.V.

    1980-01-01

    This monograph is the first one in the world literature that gives th generalised experience in application of the up-to-date method of structural and functional analysis, i.e. of electron-microscopic autography to study the dynamics of intracellular processes under normal conditions as well as under some pathogenic effects. Given herein are the data on synthesis of DNA and RNA in various structures of the nucleus, particularly in nucleoli, the regularities of the synthesis processes in the organellae of the same name are discussed; illustrated are the possibilities of structure analysis of biosynthesis intensity variations in the nucleus and cytoplasma in cells of liver miocardium, granulation tissue at different stages of morphological process; the results of electron-microscopic radioautography application in study of clinical biopsy material are given and the data obtained are discussed in the light of general pathology problems

  12. In situ transmission electron microscope studies of ion irradiation-induced and irradiation-enhanced phase changes

    International Nuclear Information System (INIS)

    Allen, C.W.

    1992-01-01

    Motivated at least initially by materials needs for nuclear reactor development, extensive irradiation effects studies employing transmission electron microscopes (TEM) have been performed for several decades, involving irradiation-induced and irradiation-enhanced microstructural changes, including phase transformations such as precipitation, dissolution, crystallization, amorphization, and order-disorder phenomena. From the introduction of commercial high voltage electron microscopes (HVEM) in the mid-1960s, studies of electron irradiation effects have constituted a major aspect of HVEM application in materials science. For irradiation effects studies two additional developments have had particularly significant impact; the development of TEM specimen holder sin which specimen temperature can be controlled in the range 10-2200 K and the interfacing of ion accelerators which allows in situ TEM studies of irradiation effects and the ion beam modification of materials within this broad temperature range. This paper treats several aspects of in situ studies of electron and ion beam-induced and enhanced phase changes and presents two case studies involving in situ experiments performed in an HVEM to illustrate the strategies of such an approach of the materials research of irradiation effects

  13. Compact cryogenic Kerr microscope for time-resolved studies of electron spin transport in microstructures

    NARCIS (Netherlands)

    Rizo, P. J.; Pugzlys, A.; Liu, J.; Reuter, D.; Wieck, A. D.; van der Wal, C. H.; van Loosdrecht, P. H. M.; Pugžlys, A.

    2008-01-01

    A compact cryogenic Kerr microscope for operation in the small volume of high-field magnets is described. It is suited for measurements both in Voigt and Faraday configurations. Coupled with a pulsed laser source, the microscope is used to measure the time-resolved Kerr rotation response of

  14. Macrophages and mast cells in dystrophic masseter muscle: a light and electron microscopic study

    DEFF Research Database (Denmark)

    Kirkeby, S; Mikkelsen, H

    1988-01-01

    Macrophages and mast cells in masseter muscle from normal and dystrophic mice were studied by light and electron microscopy. Acid phosphatase activity and FITC-dextran were used to identify and describe macrophages. Toluidine blue was used as a marker for mast cells. In dystrophic muscle, the num......Macrophages and mast cells in masseter muscle from normal and dystrophic mice were studied by light and electron microscopy. Acid phosphatase activity and FITC-dextran were used to identify and describe macrophages. Toluidine blue was used as a marker for mast cells. In dystrophic muscle...

  15. Studies of dislocation loops produced by irradiation of ZnO in a high-voltage electron microscope

    International Nuclear Information System (INIS)

    Yoshiie, T.; Iwanaga, H.; Shibata, N.; Suzuki, K.; Takeuchi, S.

    1980-01-01

    Electron-irradiation studies on vapour-grown ZnO ribbon crystals have been carried out in situ in a high-voltage electron microscope. Dislocation loops nucleate both on stacking-fault planes and in the matrix by irradiation with electron accelerated through voltages higher than 700 kV at room temperature. Two types of loops with the Burgers vectors b=1/2c and b=a exist in the matrix, where a=1/3 and c=[0001]. On the other hand, loops with b=1/2c+a/3 and those with b=1/2c are formed on the prismatic fault planes and basal fault planes, respectively. Diffraction-contrast experiments show these loops to be of interstitial type. A re-irradiation experiment after the annealing indicates a possibility that there exist vacancies in the matrix at 700 0 C. (author)

  16. In situ disordering of monoclinic titanium monoxide Ti5O5 studied by transmission electron microscope TEM.

    Science.gov (United States)

    Rempel, А А; Van Renterghem, W; Valeeva, А А; Verwerft, M; Van den Berghe, S

    2017-09-07

    The superlattice and domain structures exhibited by ordered titanium monoxide Ti 5 O 5 are disrupted by low energy electron beam irradiation. The effect is attributed to the disordering of the oxygen and titanium sublattices. This disordering is caused by the displacement of both oxygen and titanium atoms by the incident electrons and results in a phase transformation of the monoclinic phase Ti 5 O 5 into cubic B1 titanium monoxide. In order to determine the energies required for the displacement of titanium or oxygen atoms, i.e. threshold displacement energies, a systematic study of the disappearance of superstructure reflections with increasing electron energy and electron bombardment dose has been performed in situ in a transmission electron microscope (TEM). An incident electron energy threshold between 120 and 140 keV has been observed. This threshold can be ascribed to the displacements of titanium atoms with 4 as well as with 5 oxygen atoms as nearest neighbors. The displacement threshold energy of titanium atoms in Ti 5 O 5 corresponding with the observed incident electron threshold energy lies between 6.0 and 7.5 eV. This surprisingly low value can be explained by the presence of either one or two vacant oxygen lattice sites in the nearest neighbors of all titanium atoms.

  17. Light and electron microscopic study of Pelomyxa binucleata (Gruber, 1884) (Peloflagellatea, Pelobiontida)

    OpenAIRE

    Frolov, Alexander; Chystjakova, Ludmila; Goodkov, Andrew

    2005-01-01

    Morphology of a pelobiont Pelomyxa binucleata (Gruber, 1884) has been studied using light and electron microscopy. The organisation of P. binucleata has been shown to differ from that of P. palustris, P. prima and P. corona. The cell surface of P. binucleata is represented by the plasma membrane with a thin but distinct layer of non structured glycocalyx. The ectoplasm, containing a network of fine fibrils, is separated from the endoplasm with a boundary layer of cisterns and reticulum channe...

  18. Studies on electronic properties of solids in Japan. Traces toward microscopic world

    International Nuclear Information System (INIS)

    Ishiguro, Takehiko

    2005-01-01

    Properties of solids are determined by the microscopic structure where quantum mechanics stands. Throughout the 20th century physicists have made progress in developing the methods to explore the microscopic world of materials. In the latter half of the 20th century, starting with catching-up modes, Japanese solid-state physicists have been at some leading edges in the last decade. Trace towards the frontiers are briefly reviewed placing emphasis upon the material development and the investigation, and ways to go are mentioned. (author)

  19. Ciliary body toxicities of systemic oxcarbazepine and valproic acid treatments: electron microscopic study.

    Science.gov (United States)

    Göktaş, Güleser; Aktaş, Zeynep; Erdoğan, Deniz; Seymen, Cemile Merve; Karaca, Emine Esra; Cansu, Ali; Serdaroğlu, Ayşe; Kaplanoğlu, Gülnur Take

    2015-01-01

    Ciliary body is responsible for humour aqueous production in posterior chamber. Valproic acid (VPA) has been widely used for the treatment of epilepsy and other neuropsychiatric diseases such as bipolar disease and major depression. Oxcarbazepine (OXC) is a new anti-epileptic agent that has been used recently for childhood epilepsies such as VPA. In this study, we aimed to investigate the effects of VPA and OXC treatments used as antiepileptic in ciliary body by electron microscopy. In our study, 40 Wistar rats (21 days old) were divided equally into four groups which were applied saline (group 1), VPA (group 2), OXC (group 3) and VPA + OXC (group 4). The as-prepared ocular tissues were characterized by transmission electron microscopy (TEM) technique in scanning and transmission electron microscopy (SEM-TEM) (Carl Zeiss EVO LS10). The results confirmed that VPA caused dense ciliary body degeneration. Additionally, ciliary body degeneration in group 4 was supposed to be due to VPA treatment. Ciliary body damage and secondary outcomes should be considered in patients with long-term VPA therapy.

  20. Theoretical modelling of semiconductor surfaces microscopic studies of electrons and photons

    CERN Document Server

    Srivastava, G P

    1999-01-01

    The state-of-the-art theoretical studies of ground state properties, electronic states and atomic vibrations for bulk semiconductors and their surfaces by the application of the pseudopotential method are discussed. Studies of bulk and surface phonon modes have been extended by the application of the phenomenological bond charge model. The coverage of the material, especially of the rapidly growing and technologically important topics of surface reconstruction and chemisorption, is up-to-date and beyond what is currently available in book form. Although theoretical in nature, the book provides

  1. Alcoholic liver injury: defenestration in noncirrhotic livers--a scanning electron microscopic study

    DEFF Research Database (Denmark)

    Horn, T; Christoffersen, P; Henriksen, Jens Henrik Sahl

    1987-01-01

    The fenestration of hepatic sinusoidal endothelial cells in 15 needle biopsies obtained from chronic alcoholics without cirrhosis was studied by scanning electron microscopy. As compared to nonalcoholics, a significant reduction in the number of fenestrae and porosity of the sinusoidal lining wall...... (fractional area of fenestrae) was observed in acinar Zone 3, both in biopsies with and without Zone 3 fibrosis as judged by light microscopy. A significant reduction of porosity as shown in this study may influence the blood hepatocytic exchange and contribute to the alcohol-induced liver injury....

  2. Designs for a quantum electron microscope.

    Science.gov (United States)

    Kruit, P; Hobbs, R G; Kim, C-S; Yang, Y; Manfrinato, V R; Hammer, J; Thomas, S; Weber, P; Klopfer, B; Kohstall, C; Juffmann, T; Kasevich, M A; Hommelhoff, P; Berggren, K K

    2016-05-01

    One of the astounding consequences of quantum mechanics is that it allows the detection of a target using an incident probe, with only a low probability of interaction of the probe and the target. This 'quantum weirdness' could be applied in the field of electron microscopy to generate images of beam-sensitive specimens with substantially reduced damage to the specimen. A reduction of beam-induced damage to specimens is especially of great importance if it can enable imaging of biological specimens with atomic resolution. Following a recent suggestion that interaction-free measurements are possible with electrons, we now analyze the difficulties of actually building an atomic resolution interaction-free electron microscope, or "quantum electron microscope". A quantum electron microscope would require a number of unique components not found in conventional transmission electron microscopes. These components include a coherent electron beam-splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interaction-free detection of the specimen. Different system designs are presented here, which are based on four different choices of two-state-couplers: a thin crystal, a grating mirror, a standing light wave and an electro-dynamical pseudopotential. Challenges for the detailed electron optical design are identified as future directions for development. While it is concluded that it should be possible to build an atomic resolution quantum electron microscope, we have also identified a number of hurdles to the development of such a microscope and further theoretical investigations that will be required to enable a complete interpretation of the images produced by such a microscope. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Effect of Piper sarmentosum Extract on the Cardiovascular System of Diabetic Sprague-Dawley Rats: Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Zar Chi Thent

    2012-01-01

    Full Text Available Although Piper sarmentosum (PS is known to possess the antidiabetic properties, its efficacy towards diabetic cardiovascular tissues is still obscured. The present study aimed to observe the electron microscopic changes on the cardiac tissue and proximal aorta of experimental rats treated with PS extract. Thirty-two male Sprague-Dawley rats were divided into four groups: untreated control group (C, PS-treated control group (CTx, untreated diabetic group (D, and PS-treated diabetic group (DTx. Intramuscular injection of streptozotocin (STZ, 50 mg/kg body weight was given to induce diabetes. Following 28 days of diabetes induction, PS extract (0.125 g/kg body weight was administered orally for 28 days. Body weight, fasting blood glucose, and urine glucose levels were measured at 4-week interval. At the end of the study, cardiac tissues and the aorta were viewed under transmission electron microscope (TEM. DTx group showed increase in body weight and decrease in fasting blood glucose and urine glucose level compared to the D group. Under TEM study, DTx group showed lesser ultrastructural degenerative changes in the cardiac tissues and the proximal aorta compared to the D group. The results indicate that PS restores ultrastructural integrity in the diabetic cardiovascular tissues.

  4. Indigenous development of scanning electron microscope

    International Nuclear Information System (INIS)

    Ambastha, K.P.; Chaudhari, Y.V.; Pal, Suvadip; Tikaria, Amit; Pious, Lizy; Dubey, B.P.; Chadda, V.K.

    2009-01-01

    Scanning electron microscope (SEM) is a precision instrument and plays very important role in scientific studies. Bhabha Atomic Research Centre has taken up the job of development of SEM indigenously. Standard and commercially available components like computer, high voltage power supply, detectors etc. shall be procured from market. Focusing and scanning coils, vacuum chamber, specimen stage, control hardware and software etc. shall be developed at BARC with the help of Indian industry. Procurement, design and fabrication of various parts of SEM are in progress. (author)

  5. A scanning electron microscopic study of impala (Aepyceros melampus sperm from the Kruger National Park

    Directory of Open Access Journals (Sweden)

    D.J. Ackerman

    1996-08-01

    Full Text Available Since knowledge of sperm morphological characteristics can play an important role in semen evaluation and fertilisation, baseline data on sperm ultrastructure are required. Live spermatozoa were collected from the cauda epididymis from 64 impala rams in the Kruger National Park and 5082 spermatozoa from 40 of these impala were studied by scanning electron microscopy. The mean length of impala sperm was 59.23 @ 2.7 um. The morphology of normal sperm as well as the occurrence of abnormalities were documented. The morphology of impala sperm were compared with those of other mammals. New findings on appendages of the cytoplasmic droplet are described and interpreted.

  6. A transmission electron microscopic study of impala (Aepyceros melampus sperm from the Kruger National Park

    Directory of Open Access Journals (Sweden)

    D.J. Ackerman

    1996-08-01

    Full Text Available Since knowledge of sperm morphology can play an important role in semen evaluation and fertilisation, baseline data are required. Live spermatozoa were collected from the cauda epididymis of 64 impala rams in the Kruger National Park and studied by trans- mission electron microscopy. The morphology of normal sperm was documented. The impala sperm shares characteristics with other members of the Bovidae. The occurrence of appendages on the cytoplasmic droplet of the flagellum of impala sperm is described for the first time. A total of 31 micrographs, showing typical features of impala sperm, in sections through various planes of the sperm, are presented.

  7. Microscopic study on lasing characteristics of the UVSOR storage ring free electron laser

    Energy Technology Data Exchange (ETDEWEB)

    Hama, H. [Institute for Molecular Science, Okazaki (Japan)]|[Graduate Univ. for Advanced Stuides, Okazaki (Japan); Yamazaki, J.; Kinoshita, T. [Institute for Molecular Science, Okazaki (Japan)] [and others

    1995-12-31

    Characteristics of storage ring free electron laser (SRFEL) at a short wavelength region (UV and visible) has been studied at the UVSOR facility, Institute for Molecular Science. We have measured the laser power evolution by using a biplanar photodiode, and the micro-macro temporal structure of both the laser and the electron bunch with a dualsweep streak camera. The saturated energy of the laser micropulse in the gain-switching (Q-switching) mode has been measured as a function of the ring current. We have not observed a limitation of the output power yet within the beam current can be stored. We have analyzed the saturated micropulse energy based on a model of gain reduction due to the bunch-heating. The bunch-heating process seems to be very complicate. We derived time dependent gain variations from the shape of macropulse and the bunch length. Those two gain variations are almost consistent with each other but slightly different in detail. The gain may be not only simply reduced by the energy spread but also affected by the phase space rotation due to synchrotron oscillation of the electron bunch. As reported in previous issue, the lasing macropulse consists of a couple of micropulses that are simultaneously evolved. From high resolution two-dimensional spectra taken by the dual-sweep streak camera, we noticed considerable internal substructures of the laser micropulse in both the time distribution and the spectral shape. There are a couple of peaks separated with almost same distance in a optical bunch. Such substructure does not seem to result from statistical fluctuations of laser seeds. Although the origin of the substructure of macropulse is not dear at the present, we are going to discuss about SRFEL properties.

  8. Electron waves under the microscope

    International Nuclear Information System (INIS)

    Geim, A.

    2000-01-01

    If I were to explain to you what a velociraptor is, I would probably say that it looks like a small Tyrannosaurus rex and is about the same size as a dog. But what if you have never seen a picture of a T. rex? Every teacher or physicist trying to explain to students w hat an electron is'' has a similar, but more severe, problem. It usually takes months, if not years, of physics training to become familiar with imaginary pictures of electrons and then learn how to use them. Moreover, physicists need many different images depending on the phenomenon they want to address. However, in the last few years, real images of electron clouds and so-called quantum corrals have been taken. In the December issue of Physics World, Andrey Geim of the University of Manchester, UK, reveals how two recent experiments have allowed physicists to image electrons embedded deep inside semiconductors. (U.K.)

  9. A morphological study of molecularly imprinted polymers using the scanning electron microscope

    International Nuclear Information System (INIS)

    Paniagua Gonzalez, Gema; Fernandez Hernando, Pilar; Durand Alegria, J.S.

    2006-01-01

    Molecular imprinting is an emerging technique for producing polymers with applications in affinity-based separation, in biomimetic sensors, in catalysis, etc. This variety of uses relies upon the production of polymers with different affinities, specificities, sensitivities and loading capacities. Research into the development of molecular imprinted polymers (MIPs) with new or improved morphologies - which involves modification of the polymerisation process - is therefore underway. This paper reports a comparative study of non-covalent MIPs synthesised by 'bulk' polymerisation using digoxin as template. These were synthesised under different conditions, i.e., changing the functional monomers employed (methacrylic acid or 2-vinylpyridine), the porogens (acetonitrile or dichloromethane) used, and by altering the volume of the latter. The polymerisation process was allowed to proceed either under UV light or in a thermostat-controlled waterbath. The surface morphology (was determined by scanning electron microscopy) and the ability of the different polymers to selectively rebind the template was then evaluated

  10. Matrix mineralogy of the Lance CO3 carbonaceous chondrite - A transmission electron microscope study

    Science.gov (United States)

    Keller, Lindsay P.; Buseck, Peter R.

    1990-01-01

    Results are presented on electron microprobe analyses of three CO chondrites, all of which are falls: Lance, Kainsaz, and Warrenton. The TEM mineralogy results of Lance chondrite show that Fe-rich matrix olivines have been altered to Fe-bearing serpentine and Fe(3+) oxide; matrix metal was also altered to produce Fe(3+) oxides, leaving the residual metal enriched in Ni. Olivine grains in Lance's matrix contain channels along their 100-line and 001-line directions; the formation and convergence of such channels resulted in a grain-size reduction of the olivine. A study of Kainsaz and Warrenton showed that these meteorites do not contain phyllosilicates in their matrices, although both contain Fe(3+) oxide between olivine grains. It is suggested that, prior to its alteration, Lance probably resembled Kainsaz, an unaltered CO3 chondrite.

  11. Studying antimicrobial-induced morphostructural damage of bacteria by Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Shruti Shukla

    2015-12-01

    Full Text Available In this investigation, a scanning electron microscopy (SEM method was used to examine the morphostructural changes in bacterial cells induced by antimicrobial agents. SEM-based visual approach is referred the study of bacterial cells and their physiological consequences when affected by antibiotics or antibacterial agents permitting the observation of characteristic morphological defects of cell wall, and provides valuable insights into processes involved in bacterial cell death. This experiment visualized various step-by-step techniques used in the slide preparation of bacterial cells treated with specific antimicrobial agent for analyzing the morphological alterations such as increase of cell wall roughness, cell disruption, cell swelling and lysed cell formation due to loss of intracellular material using SEM analysis when compared with untreated normal cells as a control. The SEM approach used in this visual experiment may analyze the antimicrobial effect of any commercially known or new compounds in a very conducive manner.

  12. Electron microscope studies of methotrexate and radiation effects in human squamous cell carcinoma of the mouth

    International Nuclear Information System (INIS)

    De Martino, C.

    1974-01-01

    Serial biopsy specimens from two squamous cell carcinomas of the mouth were studied by electron microscopy. This report described the ultrastructural changes in the cells produced by treatment with methotrexate followed by irradiation. The main ultrastructural findings after treatment are: numerous autophagic lysosomes and residual bodies are visible in the cytoplasm of the tumor cells; mitochondria are swollen. The mitochondrial cristae are distorted and disrupted, and mitochondrial matrix disappears; the nucleolus shows a series of morphological changes such as development of a compact nucleolus, aggregation of granular elements, atrophy, dissolution and fragmentation of the nucleolar mass; infiltration of lymphocytes, granulocytes and macrophages in the tumor. The significance of these ultrastructural findings is discussed. (U.S.)

  13. The Tubular Penetration Depth and Adaption of Four Sealers: A Scanning Electron Microscopic Study

    Directory of Open Access Journals (Sweden)

    Huan Chen

    2017-01-01

    Full Text Available Background. The tubular penetration and adaptation of the sealer are important factors for successful root canal filling. The aim of this study was to evaluate the tubular penetration depth of four different sealers in the coronal, middle, and apical third of root canals as well as the adaptation of these sealers to root canal walls. Materials and Methods. 50 single-rooted teeth were prepared in this study. Forty-eight of them were filled with different sealers (Cortisomol, iRoot SP, AH-Plus, and RealSeal SE and respective core filling materials. Then the specimens were sectioned and scanning electron microscopy was employed to assess the tubular penetration and adaptation of the sealers. Results. Our results demonstrated that the maximum penetration was exhibited by RealSeal SE, followed by AH-Plus, iRoot SP, and Cortisomol. As regards the adaptation property to root canal walls, AH-Plus has best adaptation capacity followed by iRoot SP, RealSeal SE, and Cortisomol. Conclusion. The tubular penetration and adaptation vary with the different sealers investigated. RealSeal SE showed the most optimal tubular penetration, whereas AH-Plus presented the best adaptation to the root canal walls.

  14. Comparison of different retreatment techniques and root canal sealers: a scanning electron microscopic study

    Directory of Open Access Journals (Sweden)

    Neslihan Simsek

    2014-05-01

    Full Text Available The aim of this study was to evaluate the effectiveness of two retreatment techniques, in terms of the operating time and scanning electron microscopy (SEM results, in removing three different root canal sealers from root canals that were previously filled with gutta-percha. Sixty extracted single-rooted human premolars were divided into three groups and filled with iRoot SP, MM Seal, and AH Plus sealers, along with gutta-percha, through a lateral compaction technique. Root canal fillings of the samples were removed by ESI ultrasonic tips or R-Endo files. The time to reach the working length was recorded. Longitudinally sectioned samples were examined under SEM magnification. Each picture was evaluated in terms of the residual debris. Data were statistically analyzed with the Kruskall-Wallis test. No statistically significant differences were found in terms of operating time (p>0.05. Significant differences in the number of debris-free dentinal tubules were found among the root canal thirds, but this finding was not influenced by the experimental group (p < 0.05. Resin sealer tags were observed inside the dentinal tubules in the MM Seal group. Under the conditions of this study, it may be established that there was no difference among the sealers and retreatment techniques.

  15. Scanning electron microscopical study of the lingual epithelium of green iguana (Iguana iguana).

    Science.gov (United States)

    Abbate, F; Latella, G; Montalbano, G; Guerrera, M C; Levanti, M B; Ciriaco, E

    2008-08-01

    During the last few years, green iguanas (Iguana iguana) have turned out to be one of the most popular pets. They are omnivorous. In their way of feeding, this crucial function is performed by capturing of the preys and mostly, this is carried out by the tongue. The role of the tongue is also fundamental during the intra-oral transport and during the swallowing of food. This has been reported in several studies about chameleons, agamids and iguanids, nevertheless published data about the mechanisms of capturing and swallowing the prey, and the morphological descriptions about the tongue epithelium, are scarce. Therefore, the aim of this present study was to analyse the morphology of the lingual epithelium in green iguanas by scanning electron microscopy. Three different areas were demonstrated on the tongue surface: the tongue tip, characterized by a smooth epithelium without papillae, a foretongue, completely covered by numerous closely packed cylindriform papillae, and a hindtongue with conical-like papillae. Some taste buds were recognized on the middle and the posterior parts of the tongue. Different functional roles could be hypothesized for the three tongue areas: the tongue tip could have a role related to the movements of the prey immediately after the capturing, while the middle papillae and the hindtongue could have an important role concerning the swallowing phase.

  16. Silver deposition in the central nervous system and the hematoencephalic barrier studied with the electron microscope.

    Science.gov (United States)

    VAN BREEMEN, V L; CLEMENTE, C D

    1955-03-01

    For the purpose of studying the hematoencephalic barrier as it is concerned with silver circulating in the blood stream, silver nitrate was vitally administered to rats in their drinking water over periods of 6 to 8 months. The cerebrum, cerebellum, medulla, area postrema, and choroid plexus were prepared for light and electron microscopy. Silver deposition was found in the perivascular spaces in the choroid plexus, area postrema, in the medulla surrounding the area postrema, and in minute quantities in the cerebrum, cerebellum, and most of the medulla. Two levels of the hematoencephalic barrier were apparently demonstrated in our investigations. The endothelial linings of the vessels in the cerebrum, cerebellum, and medulla constitute the first threshold of the hematoencephalic barrier (specifically here, blood-brain barrier). The cell membranes adjacent to the perivascular spaces form the second threshold, as follows:-the neuroglial cell membranes in the cerebrum, cerebellum, and medulla (blood-brain barrier); the membranes of the neuroglial cells in the area postrema (blood-brain barrier); and the membranes of the epithelial cells of the choroid plexus (blood-cerebrospinal fluid barrier). This study deals with silver deposition and does not infer that the penetration of ionic silver, if present in the blood stream, would necessarily be limited to the regions described. Bleb-like structures were observed to cover the epithelial cell surfaces in the choroid plexus. They may be cellular projections increasing the cell surface area or they may be secretory droplets.

  17. Transmission electron microscope studies of the nuclear envelope in Caenorhabditis elegans embryos.

    Science.gov (United States)

    Cohen, Merav; Tzur, Yonatan B; Neufeld, Esther; Feinstein, Naomi; Delannoy, Michael R; Wilson, Katherine L; Gruenbaum, Yosef

    2002-01-01

    Nuclear membranes and nuclear pore complexes (NPCs) are conserved in both animals and plants. However, the lamina composition and the dimensions of NPCs vary between plants, yeast, and vertebrates. In this study, we established a protocol that preserves the structure of Caenorhabditis elegans embryonic cells for high-resolution studies with thin-section transmission electron microscopy (TEM). We show that the NPCs are bigger in C. elegans embryos than in yeast, with dimensions similar to those in higher eukaryotes. We also localized the C. elegans nuclear envelope proteins Ce-lamin and Ce-emerin by pre-embedding gold labeling immunoelectron microscopy. Both proteins are present at or near the inner nuclear membrane. A fraction of Ce-lamin, but not Ce-emerin, is present in the nuclear interior. Removing the nuclear membranes leaves both Ce-lamin and Ce-emerin associated with the chromatin. Eliminating the single lamin protein caused cell death as visualized by characteristic changes in nuclear architecture including condensation of chromatin, clustering of NPCs, membrane blebbing, and the presence of vesicles inside the nucleus. Taken together, these results show evolutionarily conserved protein localization, interactions, and functions of the C. elegans nuclear envelope.

  18. Real-time studies of battery electrochemical reactions inside a transmission electron microscope.

    Energy Technology Data Exchange (ETDEWEB)

    Leung, Kevin; Hudak, Nicholas S.; Liu, Yang; Liu, Xiaohua H.; Fan, Hongyou; Subramanian, Arunkumar; Shaw, Michael J.; Sullivan, John Patrick; Huang, Jian Yu

    2012-01-01

    We report the development of new experimental capabilities and ab initio modeling for real-time studies of Li-ion battery electrochemical reactions. We developed three capabilities for in-situ transmission electron microscopy (TEM) studies: a capability that uses a nanomanipulator inside the TEM to assemble electrochemical cells with ionic liquid or solid state electrolytes, a capability that uses on-chip assembly of battery components on to TEM-compatible multi-electrode arrays, and a capability that uses a TEM-compatible sealed electrochemical cell that we developed for performing in-situ TEM using volatile battery electrolytes. These capabilities were used to understand lithiation mechanisms in nanoscale battery materials, including SnO{sub 2}, Si, Ge, Al, ZnO, and MnO{sub 2}. The modeling approaches used ab initio molecular dynamics to understand early stages of ethylene carbonate reduction on lithiated-graphite and lithium surfaces and constrained density functional theory to understand ethylene carbonate reduction on passivated electrode surfaces.

  19. Spectroscopy of electron irradiated polymers in electron microscope

    International Nuclear Information System (INIS)

    Faraj, S.H.; Salih, S.M.

    1981-01-01

    The damage induced by energetic electrons in the course of irradiation of polymers in a transmission electron microscope was investigated spectroscopically. Damage on the molecular level has been detected at very low exposure doses. These effects have been induced by electron doses less than that received by the specimen when it is situated at its usual place of the specimen stage in the electron microscope by a factor of 1,000. (author)

  20. [Electron microscopic detection rate of enteral viruses in diarrhea of dogs, cats, calves, swine and foals in the year 1988--electron microscopic study results].

    Science.gov (United States)

    Biermann, U; Herbst, W; Krauss, H; Schliesser, T

    1989-12-01

    During 1988 fecal and gut samples of 641 dogs, 198 cats, 576 calves, 108 piglets and 64 foals with diarrhoea were investigated for virus infections by electron microscopy. In samples of dogs and cats parvovirus was detected at a proportion of 21.9% and 16.7%, respectively; rotavirus alone or together with coronavirus was found only in 0.3-1.5% of the specimens. In samples of calves rotavirus, as well as coronavirus dominated with a detection rate amounting to 17.4% and 26.6% respectively (including 4.5% of mixed infections); parvovirus was present in a ratio of 0.5%. Specimens of piglets mainly contained coronavirus (25.0%), and in lower percentages rotavirus (2.8%), rota- and coronaviruses (0.9%) and parvovirus (0.9%). In feces of foals rotavirus was detected in 6.3% and particles resembling picornavirus in 4.7% of cases. Not identifiable virus particles resembling corona-or picornaviruses were rarely found (between 0.6-2.5) also in specimens of the other animal species.

  1. Electron microscope study of the genesis of strain-induced martensite embryos

    International Nuclear Information System (INIS)

    Staudhammer, K.P.; Hecker, S.S.; Murr, L.E.

    1984-01-01

    Previous work of Olson and Cohen and Murr, et al., is used to describe the genesis of martensite embryos which form at the intersection of microscopic shear bands in deformed type 304 stainless steel. It is shown that the intersection volume included within intersecting shear bands contains irregular and smaller dispersed volume segments forming α' martensite (bcc). These correspond to the satisfaction of specific intersections of stacking faults or partial dislocations on approximately every second (111)/sub fcc/ plane in one direction, and every third (111)/sub fcc/ plane in the other (conjugate) direction. The requisite stacking fault or partial dislocation arrangements are produced in an irregular fashion resulting in α' martensite embryos nucleating in an incomplete and irregular fashion within the intersection volume. 9 references, 2 figures

  2. Histopathological and electron microscopic studies of lymphangiectasia of the small intestine in Behçet's disease

    Science.gov (United States)

    Asakura, Hitoshi; Morita, Akira; Morishita, Tetsuo; Tsuchiya, Masaharu; Watanabe, Yoonosuke; Enomoto, Yasuhiro

    1973-01-01

    The gastrointestinal involvement and immunological findings in 16 patients with Behçet's disease are described. Four of 15 biopsy specimens of jejunal mucosa showed marked lymphangiectasia in the lamina propria similar to the appearance which was thought to be a characteristic finding in protein-losing enteropathy. None of the patients had hypoproteinaemia. Increases in serum immunoglobulin IgA were proved in six of 15 cases; in IgM, five of 15; and in IgG, one of 15. Electron microscopic studies showed that there were thousands of precipitated lymph protein bodies in the extracellular spaces of the lamina propria. Ulcers and healed ulcers of the large intestine were studied by light microscopy. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 7Fig. 8Fig. 9 PMID:4700433

  3. Electron microscopic study of spontaneous and experimentally induced leukemia in IRC mice

    International Nuclear Information System (INIS)

    Hiraki, S.; Ranadive, K.J.; Dmochowski, L.

    1974-01-01

    Spontaneous, serially transplanted, and experimentally induced leukemias of ICRC mice were studied by electron microscopy in an attempt to detect the presence of virus particles, if any, and to observe the influence of chemical and hormonal treatment on the presence of these virus particles. The first series of experiments included spontaneous, serially transplanted, and radiation-induced leukemia. The paucity of type C virus particles was quite conspicuous in spontaneous leukemia. Serially transplanted and radiation-accelerated leukemic lesions showed the presence of some type C and intracisternal type A particles. Found in two of these leukemic lesions (thymus and lymphosarcoma), in addition to type C virus particles, were budding and some mature type B virus particles, and numerous intracytoplasmic type A particles. ''Viropexis'' of type B virus particles has been observed in the lymphosarcoma and in a leukemic thymus gland. The second series of experiments included leukemia induced in ovariectomized ICRC mice with 20-methylcholanthrene (MCA), pituitary transplants, and ovarian hormones (estradiol and estradiol-progesterone). In ovariectomized ICRC mice, leukemic lesions induced by MCA or pituitary transplants, or by MCA and pituitary transplants, showed type C virus particles and, in most cases, intracisternal type A particles. In leukemia induced in ovariectomized ICRC mice by MCA and estradiol, numerous intracytoplasmic type A particles were observed but no type C virus particles

  4. Scanning electron and light microscopic study of microbial succession on bethlehem st. Nectaire cheese.

    Science.gov (United States)

    Marcellino, S N; Benson, D R

    1992-11-01

    St. Nectaire cheese is a semisoft cheese of French origin that, along with Brie and Camembert cheeses, belongs to the class of surface mold-ripened cheese. The surface microorganisms that develop on the cheese rind during ripening impart a distinctive aroma and flavor to this class of cheese. We have documented the sequential appearance of microorganisms on the cheese rind and in the curd over a 60-day ripening period. Scanning electron microscopy was used to visualize the development of surface fungi and bacteria. Light microscopy of stained paraffin sections was used to study cross sections through the rind. We also monitored the development of bacterial and yeast populations in and the pH of the curd and rind. The earliest stage of ripening (0 to 2 days) is dominated by the lactic acid bacterium Streptococcus cremoris and multilateral budding yeasts, primarily Debaryomyces and Torulopsis species. Geotrichum candidum follows closely, and then zygomycetes of the genus Mucor develop at day 4 of ripening. At day 20, the deuteromycete Trichothecium roseum appears. From day 20 until the end of the ripening process, coryneforms of the genera Brevibacterium and Arthrobacter can be seen near the surface of the cheese rind among fungal hyphae and yeast cells.

  5. Subchondral bone failure in overload arthrosis: a scanning electron microscopic study in horses.

    Science.gov (United States)

    Norrdin, R W; Stover, S M

    2006-01-01

    Mechanical overload leads to a common arthrosis in the metacarpal condyle of the fetlock joint of racehorses. This is usually asymptomatic but severe forms can cause lameness. Subchondral bone failure is often present and the predictability of the site provided an opportunity to study of the progression of bone failure from microcracks to actual collapse of subchondral bone. Twenty-five fetlock condyles from racehorses with various stages of disease were selected. Stages ranged from mild through severe subchondral bone sclerosis, to the collapse of bone and indentation or loss of cartilage known as 'traumatic osteochondrosis'. Parasagittal slices were radiographed and examined with scanning electron microscopy. Fine matrix cracks were seen in the subchondral bone layer above the calcified cartilage and suggested loss of water or other non-collagenous components. The earliest microcracks appeared to develop in the sclerotic bone within 1-3 mm of the calcified cartilage layer and extend parallel to it in irregular branching lines. Longer cracks or microfractures appeared to develop gaps as fragmentation occurred along the margins. Occasional osteoclastic resorption sites along the fracture lines indicated activated remodeling may have caused previous weakening. In one sample, smoothly ground fragments were found in a fracture gap. Bone collapse occurred when there was compaction of the fragmented matrix along the microfracture. Bone collapse and fracture lines through the calcified cartilage were associated with indentation of articular cartilage at the site.

  6. Scanning electron microscopic study of Piper betle L. leaves extract effect against Streptococcus mutans ATCC 25175.

    Science.gov (United States)

    Rahim, Zubaidah Haji Abdul; Thurairajah, Nalina

    2011-04-01

    Previous studies have shown that Piper betle L. leaves extract inhibits the adherence of Streptococcus mutans to glass surface, suggesting its potential role in controlling dental plaque development. In this study, the effect of the Piper betle L. extract towards S. mutans (with/without sucrose) using scanning electron microscopy (SEM) and on partially purified cell-associated glucosyltransferase activity were determined. S. mutans were allowed to adhere to glass beads suspended in 6 different Brain Heart Infusion broths [without sucrose; with sucrose; without sucrose containing the extract (2 mg mL(-1) and 4 mg mL(-1)); with sucrose containing the extract (2 mg mL(-1) and 4 mg mL(-1))]. Positive control was 0.12% chlorhexidine. The glass beads were later processed for SEM viewing. Cell surface area and appearance and, cell population of S. mutans adhering to the glass beads were determined upon viewing using the SEM. The glucosyltransferase activity (with/without extract) was also determined. One- and two-way ANOVA were used accordingly. It was found that sucrose increased adherence and cell surface area of S. mutans (pPiper betle L. leaves extract. It was also found that the extract inhibited glucosyltransferase activity and its inhibition at 2.5 mg mL(-1) corresponded to that of 0.12% chlorhexidine. At 4 mg mL(-1) of the extract, the glucosyltransferase activity was undetectable and despite that, bacterial cells still demonstrated adherence capacity. The SEM analysis confirmed the inhibitory effects of the Piper betle L. leaves extract towards cell adherence, cell growth and extracellular polysaccharide formation of S. mutans visually. In bacterial cell adherence, other factors besides glucosyltransferase are involved.

  7. A scanning electron microscopic study of the patterns of external root resorption under different conditions

    Directory of Open Access Journals (Sweden)

    Ravindran Sreeja

    2009-10-01

    Full Text Available OBJECTIVE: The aim of this study was to examine if there are qualitative differences in the appearance of external root resorption patterns of primary teeth undergoing physiologic resorption and permanent teeth undergoing pathological root resorption in different conditions. MATERIAL AND METHODS: A total of 40 teeth undergoing external root resorption in different conditions were divided into 4 groups and prepared for examination under scanning electron microscopy at magnifications ranging from 20x to 1000x. Group I: 10 primary molars exfoliated due to physiologic root resorption; Group II: 10 permanent teeth with periapical granulomas showing signs of resorption; Group III:10 permanent teeth therapeutically extracted during the course of orthodontic therapy with evidence of resorption, and Group IV: 10 permanent teeth associated with odontogenic tumors that showed evidence of resorption. RESULTS: In Group I, the primary teeth undergoing resorption showed smooth extensive and predominantly regular areas reflecting the slow ongoing physiologic process. In Group II, the teeth with periapical granulomas showed the resorption was localized to apex with a funnel shaped appearance in most cases. Teeth in Group III, which had been subjected to a short period of light orthodontic force, showed the presence of numerous resorption craters with adjoining areas of cemental repair in some cases. Teeth associated with odontogenic tumors in Group IV showed many variations in the patterns of resorption with extensive loss of root length and a sharp cut appearance of the root in most cases. CONCLUSION: Differences were observed in the patterns of external root resorption among the studied groups of primary and permanent teeth under physiologic and pathological conditions.

  8. Elaphostrongylus spp. from Scandinavian cervidae - a scanning electron microscope study (SEM

    Directory of Open Access Journals (Sweden)

    Margareta Stéen

    1990-08-01

    Full Text Available Nematodes of the genus Elaphostrongylus collected from moose (Alces alces L., reindeer (Rangifer tarandus tarandus L., and red deer (Cervus elaphus L., respectively, were studied by means of scanning electron microscopy. Morphological differences in the ribs of the genital bursa were demonstrated. The Elaphostrongylus species from reindeer and red deer differed from each other in four ribs of the genital bursa. These results agree with the morphological characters of E. cervi and E. rangiferi described by Cameron (1931 and Mitskevitch (1960. The genital bursa of Elaphostrongylus sp. from moose, in accordance with the description of E. alces by Steen et al. (1989 showed characteristics differing from those found in Elaphostrongylus spp. from reindeer and red deer respectively. These results support the hypothesis that there are three separate species of Elaphostrongylus present in Scandinavian Cervidae. Svep-elektroniska studier på Elaphostrongylus spp. hos skandinaviska hjortdjur.Abstract in Swedish / Sammandrag: Rundmaskar inom slaktet Elaphostrongylus funna hos alg (Alces alces L., ren (Rangifer tarandus tarandus L. och kronhjort(Cervus elaphus L. studerades med hjalp av svepelelektronmikroskop. De hanliga bursorna med sin a stodjeribbor uppvisade variationer i utseende, langd och placering mellan dessa rundmaskar. De arter av Elaphostrongylus funna hos ren och kronhjort skilde sig åt avseende fyra stodjeribbor på de hanliga bursorna. Dessa resultat stammer val overens med de karaktarer som tidigare ar beskrivna av Cameron(1931 och av Mitskevich (1960. Den hanliga bursan hos arten Elaphostrongylus funnen hos alg, vilken tidigare ar beskriven av Steen et al. (1989, visade upp ett utseende som skilde sig från bursorna hos de Elaphostrongylus-arter funna hos ren och kronhjort. Dessa resultat stoder hypotesen om tre skilda arter av Elaphostrongylus hos skandinaviska hjortdjur.

  9. Comparative scanning electron microscopic study of the effect of different dental conditioners on dentin micromorphology

    Directory of Open Access Journals (Sweden)

    Alexandre Henrique Susin

    2008-04-01

    Full Text Available This study evaluated comparatively by scanning electron microscopy (SEM the effect of different dental conditioners on dentin micromorphology, when used according to the same protocol. Forty dentin sticks were obtained from 20 caries-free third human molars and were assigned to 4 groups corresponding to 3 conditioners (phosphoric acid 37%, Clearfil SE Bond and iBond and an untreated control group. After application of the conditioners, the specimens were immersed in 50% ethanol solution during 10 s, chemically fixed and dehydrated to prepare them to SEM analysis. In the control group, dentin surface was completely covered by smear layer and all dentinal tubules were occluded. In the phosphoric acid-etched group, dentin surface was completely clean and presented exposed dentinal tubule openings; this was the only group in which the tubules exhibited the funnel-shaped aspect. In the groups conditioned with Clearfil SE Bond primer and iBond, which are less acidic than phosphoric acid, tubule openings were occluded or partially occluded, though smear layer removal was observed. SE Bond was more efficient in removing the smear layer than iBond. In the Clearfil SE Bond group, the cuff-like aspect of peritubular dentin was more evident. It may be concluded all tested conditioners were able to change dentin morphology. However, it cannot be stated that the agent aggressiveness was the only cause of the micromorphological alterations because a single morphological pattern was not established for each group, but rather an association of different aspects, according to the aggressiveness of the tested conditioner.

  10. Metal particle emissions in the exhaust stream of diesel engines: an electron microscope study.

    Science.gov (United States)

    Liati, Anthi; Schreiber, Daniel; Dimopoulos Eggenschwiler, Panayotis; Arroyo Rojas Dasilva, Yadira

    2013-12-17

    Scanning electron microscopy and transmission electron microscopy were applied to investigate the morphology, mode of occurrence and chemical composition of metal particles (diesel ash) in the exhaust stream of a small truck outfitted with a typical after-treatment system (a diesel oxidation catalyst (DOC) and a downstream diesel particulate filter (DPF)). Ash consists of Ca-Zn-P-Mg-S-Na-Al-K-phases (lube-oil related), Fe, Cr, Ni, Sn, Pb, Sn (engine wear), and Pd (DOC coating). Soot agglomerates of variable sizes (1-5 μm, exceptionally 13 μm), rarely engine wear and escape into the atmosphere.

  11. Comparative scanning electron microscope study of the degradation of a plasticized polyvinyl chloride waterproofing membrane in different conditions

    International Nuclear Information System (INIS)

    Pedrosa, A.; Del Río, M.

    2017-01-01

    This paper discusses the analysis of several samples of a plasticized polyvinyl chloride (PVC-P) waterproofing membrane. The samples were extracted from different areas of the same flat roof, which was in service for over 12 years. An original sample of an identical PVC-P membrane that was not installed on the roof was also analyzed. The analysis of the materials was carried out using a scanning electron microscope (SEM). An elemental analysis of every sample was also performed by energy dispersive X-ray spectroscopy (EDS). Micrographs and the elemental composition of the samples were compared with the data obtained in the analysis of the original sample. The results show dehydrochlorination of the polymer in two of the samples studied and great deterioration that was not visible to the naked eye in the sample that was totally exposed to the weather. [es

  12. Limits on visibility of single heavy atoms in the scanning transmission electron microscope: an experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Wall, J.S.

    1979-01-01

    Theoretical calculations of the visibility of single heavy atoms on thin carbon substrates have predicted higher signal to noise ratios then experimentally observed. Six experimental measurements were performed to determine where the theory is inadequate, five to determine the absolute value of heavy atom scattering cross sections in practical units, and one to determine substrate noise in some practical units. The practical unit of measure was chosen to be the scattering power of one carbon atom as determined by an internal standard, Tobacco Mosaic Virus. Measurements were performed on the following targets on thin carbon substrates: single isolated uranium atoms; silicotungstate clusters; colloidal platinum particles; fd bacteriophage embedded in negative strain; and fd bacteriophage reacted with a known quantity of heavy atom reagent. These measurements suggest that the scattering power of one heavy atom is approximately 9 +- 4 carbon atom equivalents, instead of 15 to 24 predicted by theory. The same techniques were used to measure intensity fluctuations from area to area of a clean substrate. Substrate noise was found to be less than expected for squares of width less than 10A, but up to 2.5 times greater than expected for larger squares. These signal and noise measurements have been combined to give an empirical formula for calculating signal to noise ratios from specimen and microscope parameters.

  13. In Situ Study of Live Specimens in an Environmental Scanning Electron Microscope

    Czech Academy of Sciences Publication Activity Database

    Tihlaříková, Eva; Neděla, Vilém; Shiojiri, M.

    2013-01-01

    Roč. 19, č. 4 (2013), s. 914-918 ISSN 1431-9276 R&D Projects: GA ČR GAP102/10/1410 Institutional support: RVO:68081731 Keywords : live biological sample * high-pressure environment * hydration system * in situ observation * Monte Carlo simulation * methodology Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.757, year: 2013

  14. Formation of a Parasitophorous Vacuole in a Nonadequate Experimental Host: Electron Microscopical and X-Ray Microanalytical Study

    Czech Academy of Sciences Publication Activity Database

    Žižka, Zdeněk

    2005-01-01

    Roč. 50, č. 1 (2005), 05-12 ISSN 0015-5632 Institutional research plan: CEZ:AV0Z50200510 Keywords : electron microscopical * x-ray Subject RIV: EE - Microbiology, Virology Impact factor: 0.918, year: 2005

  15. Transmission electron microscope study of neutron irradiation-induced defects in silicon

    International Nuclear Information System (INIS)

    Oshima, Ryuichiro; Kawano, Tetsuya; Fujimoto, Ryoji

    1994-01-01

    Commercial Czochralski-grown silicon (Cz-Si) and float-zone silicon (Fz-Si) wafers were irradiated with fission neutrons at various fluences from 10 19 to 10 22 n/cm 2 at temperatures ranging from 473 K to 1043 K. The irradiation induced defect structures were examined by transmission electron microscopy and ultra high voltage electron microscopy, which were compared with Marlowe code computer simulation results. It was concluded that the vacancy-type damage structure formed at 473 K were initiated from collapse of vacancy-rich regions of cascades, while interstitial type defect clusters formed by irradiation above 673 K were associated with interstitial oxygen atoms and free interstitials which diffused out of the cascades. Complex defect structures were identified to consist of {113} and {111} planar faults by the parallel beam illumination diffraction analysis. (author)

  16. Designs for a quantum electron microscope

    International Nuclear Information System (INIS)

    Kruit, P.; Hobbs, R.G.; Kim, C-S.; Yang, Y.; Manfrinato, V.R.; Hammer, J.; Thomas, S.; Weber, P.; Klopfer, B.; Kohstall, C.; Juffmann, T.; Kasevich, M.A.; Hommelhoff, P.; Berggren, K.K.

    2016-01-01

    One of the astounding consequences of quantum mechanics is that it allows the detection of a target using an incident probe, with only a low probability of interaction of the probe and the target. This ‘quantum weirdness’ could be applied in the field of electron microscopy to generate images of beam-sensitive specimens with substantially reduced damage to the specimen. A reduction of beam-induced damage to specimens is especially of great importance if it can enable imaging of biological specimens with atomic resolution. Following a recent suggestion that interaction-free measurements are possible with electrons, we now analyze the difficulties of actually building an atomic resolution interaction-free electron microscope, or “quantum electron microscope”. A quantum electron microscope would require a number of unique components not found in conventional transmission electron microscopes. These components include a coherent electron beam-splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interaction-free detection of the specimen. Different system designs are presented here, which are based on four different choices of two-state-couplers: a thin crystal, a grating mirror, a standing light wave and an electro-dynamical pseudopotential. Challenges for the detailed electron optical design are identified as future directions for development. While it is concluded that it should be possible to build an atomic resolution quantum electron microscope, we have also identified a number of hurdles to the development of such a microscope and further theoretical investigations that will be required to enable a complete interpretation of the images produced by such a microscope. - Highlights: • Quantum electron microscopy has the potential of reducing radiation damage. • QEM requires a fraction of the electron wave to pass through the sample

  17. Designs for a quantum electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kruit, P., E-mail: p.kruit@tudelft.nl [Department of Imaging Physics, Delft University of Technology, Lorentzweg 1, 2628CJ Delft (Netherlands); Hobbs, R.G.; Kim, C-S.; Yang, Y.; Manfrinato, V.R. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Hammer, J.; Thomas, S.; Weber, P. [Department of Physics, Friedrich Alexander University Erlangen-Nürnberg (FAU), Staudtstrasse 1, d-91058 Erlangen (Germany); Klopfer, B.; Kohstall, C.; Juffmann, T.; Kasevich, M.A. [Department of Physics, Stanford University, Stanford, California 94305 (United States); Hommelhoff, P. [Department of Physics, Friedrich Alexander University Erlangen-Nürnberg (FAU), Staudtstrasse 1, d-91058 Erlangen (Germany); Berggren, K.K. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2016-05-15

    One of the astounding consequences of quantum mechanics is that it allows the detection of a target using an incident probe, with only a low probability of interaction of the probe and the target. This ‘quantum weirdness’ could be applied in the field of electron microscopy to generate images of beam-sensitive specimens with substantially reduced damage to the specimen. A reduction of beam-induced damage to specimens is especially of great importance if it can enable imaging of biological specimens with atomic resolution. Following a recent suggestion that interaction-free measurements are possible with electrons, we now analyze the difficulties of actually building an atomic resolution interaction-free electron microscope, or “quantum electron microscope”. A quantum electron microscope would require a number of unique components not found in conventional transmission electron microscopes. These components include a coherent electron beam-splitter or two-state-coupler, and a resonator structure to allow each electron to interrogate the specimen multiple times, thus supporting high success probabilities for interaction-free detection of the specimen. Different system designs are presented here, which are based on four different choices of two-state-couplers: a thin crystal, a grating mirror, a standing light wave and an electro-dynamical pseudopotential. Challenges for the detailed electron optical design are identified as future directions for development. While it is concluded that it should be possible to build an atomic resolution quantum electron microscope, we have also identified a number of hurdles to the development of such a microscope and further theoretical investigations that will be required to enable a complete interpretation of the images produced by such a microscope. - Highlights: • Quantum electron microscopy has the potential of reducing radiation damage. • QEM requires a fraction of the electron wave to pass through the sample

  18. Vascular damage after acute local irradiation: a light and electron microscope study

    International Nuclear Information System (INIS)

    Verola, O.; Brocheriou, C.

    1986-01-01

    A pig model was used to examine histological and ultrastructural changes after high-dose local irradiation. This model was chosen to simulate accidents which have occurred in man, enabling the determination of several post-irradiation phases. After an initial phase, with superficial lesions, ischaemic necrosis occurred 3 weeks after irradiation as the result of early vascular alterations. After 2 months, expanding necrosis became obvious in the deep muscle, preceded by an initial spread of vascular lesions: these alterations were obvious from the 30th day by light microscopy but could be detected by electron microscopy from the 9th day. (author)

  19. An electron microscopic study on the effects of irradiation on the acinar cells of rat parotid gland

    International Nuclear Information System (INIS)

    Ko, Kwang Jun; Lee, Sang Rae

    1988-01-01

    The author studies the histopathologic changes according to a single or a split does and the time after irradiation on the acinar cells of rat parotid gland. 99 Sprague Dawley rats, weighing about 120 gm, were divided into control and 3 experimental groups. In experimental groups, Group I and II were delivered a single does of 15 Gy, 18 Gy and Group III and IV were delivered two equal split doses of 9 Gy, 10.5 Gy for a 4 hours interval, respectively. The experimental groups were delivered by a cobalt-60 teletherapy unit with a dose rate of 222 cGy/min, source-skin di stance of 50 cm, depth of 1 cm and a field size of 12 X 5 cm. The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and examined by light and electro n microscopy. The results were as follows: 1. As the radiation dose increased and acinar cells delivered a single dose exposure were more damaged, and the change of acinar cells appeared faster than those of a split does exposure. 2. The histopathologic change of acinar cells appeared at 1 hour after irradiation. The recovery from damaged acinar cells appeared at 1 day after irradiation and there was a tendency that the recovery from damage of a split dose exposure was somewhat later than of a single dose exposure. 3. Light microscope showed atrophic change of acinar cells and nucleus, degeneration and vesicle formation of cytoplasm, widening of intercellular space and interlobular space. 4. Electron microscope showed loss of nuclear membrane, degeneration of nucleus and nucleoli, clumping of cytoplasm, widening and degeneration of rough endoplasmic reticulum, loss of cristae of mitochondria, lysosome, autophagosome and lipid droplet. 5. Electron microscopically, the change of rough endoplasmic reticulum was most prominent and this appeared at 1 hour after irradiation as early changes of acinar cells. The nuclear change appeared at 2 hours after irradiation and the loss of cristae of mitochondria was observed at 2 hours after

  20. An electron microscopic study on the effects of irradiation on the acinar cells of rat parotid gland

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kwang Jun; Lee, Sang Rae [Dept. of Oral Radiology, College of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    1988-11-15

    The author studies the histopathologic changes according to a single or a split does and the time after irradiation on the acinar cells of rat parotid gland. 99 Sprague Dawley rats, weighing about 120 gm, were divided into control and 3 experimental groups. In experimental groups, Group I and II were delivered a single does of 15 Gy, 18 Gy and Group III and IV were delivered two equal split doses of 9 Gy, 10.5 Gy for a 4 hours interval, respectively. The experimental groups were delivered by a cobalt-60 teletherapy unit with a dose rate of 222 cGy/min, source-skin di stance of 50 cm, depth of 1 cm and a field size of 12 X 5 cm. The animals were sacrificed at 1, 2, 3, 6, 12 hours, 1, 3, 7 days after irradiation and examined by light and electro n microscopy. The results were as follows: 1. As the radiation dose increased and acinar cells delivered a single dose exposure were more damaged, and the change of acinar cells appeared faster than those of a split does exposure. 2. The histopathologic change of acinar cells appeared at 1 hour after irradiation. The recovery from damaged acinar cells appeared at 1 day after irradiation and there was a tendency that the recovery from damage of a split dose exposure was somewhat later than of a single dose exposure. 3. Light microscope showed atrophic change of acinar cells and nucleus, degeneration and vesicle formation of cytoplasm, widening of intercellular space and interlobular space. 4. Electron microscope showed loss of nuclear membrane, degeneration of nucleus and nucleoli, clumping of cytoplasm, widening and degeneration of rough endoplasmic reticulum, loss of cristae of mitochondria, lysosome, autophagosome and lipid droplet. 5. Electron microscopically, the change of rough endoplasmic reticulum was most prominent and this appeared at 1 hour after irradiation as early changes of acinar cells. The nuclear change appeared at 2 hours after irradiation and the loss of cristae of mitochondria was observed at 2 hours after

  1. High resolution electron microscope study of the omega transformation in Zr--Nb alloys

    International Nuclear Information System (INIS)

    Chang, A.L.J.; Sass, S.L.; Krakow, W.

    1976-01-01

    High resolution direct lattice imaging and dark field electron microscopy were used to examine the omega phase transformation in Zr--Nb alloys. Direct lattice imaging demonstrated the existence of subvariants within an omega variant. The existence of an ordered sequence of subvariants, which is the basic premise of recent diffuse intensity calculations which seek to explain diffuse diffraction observations in high Nb content alloys, could not be checked because of the small size of the omega regions. In the low Nb content alloys dark field electron microscopy was used to show that the ω phase consists of large domains (100 to 200 A dia) the interior of which contains features that are 3 to 6 A dia. As the Nb content is increased the omega domains decrease in size until only 3 to 5 A images are observed in alloys containing 15 wt. percent Nb or more. The isolated images are present over the range of composition from 8 to 30 wt. percent Nb. Time sequence dark field micrographs show that these small images change with time. The diffuse ω reflections are believed due in part to the existence of a (111) linear detect, consisting of groups of (111) rows of atoms which are displaced from bcc to ω positions for short periods of time

  2. Scanning electron microscopic study of hazardous waste flakes of polyethylene terephthalate (PET) by aminolysis and ammonolysis

    Energy Technology Data Exchange (ETDEWEB)

    Mittal, Alok, E-mail: aljymittal@yahoo.co.in [Department of Chemistry, Maulana Azad National Institute of Technology (A Deemed University), Bhopal 462051 (India); Soni, R.K.; Dutt, Krishna; Singh, Swati [Department of Chemistry, Ch. Charan Singh University, Meerut 250004 (India)

    2010-06-15

    Polyethylene terephthalate (PET) waste flakes were degraded with aqueous methylamine and aqueous ammonia, respectively at room temperature in the presence and absence of quaternary ammonium salt as a catalyst for different periods of time. The aminolysed and ammonolysed PET samples were investigated for the surface morphology with the help of scanning electron micrograph (SEM). It shows that the semi-crystalline PET waste samples reduce to monodisperse rods before fully degradation to the end products. The presence of the catalyst provides site for degradation of PET waste and enhances the rate of degradation. The SEM shows early developments of fissures in comparison to the one in absence of quaternary ammonium salt used as catalyst.

  3. Scanning electron microscopic study of hazardous waste flakes of polyethylene terephthalate (PET) by aminolysis and ammonolysis

    International Nuclear Information System (INIS)

    Mittal, Alok; Soni, R.K.; Dutt, Krishna; Singh, Swati

    2010-01-01

    Polyethylene terephthalate (PET) waste flakes were degraded with aqueous methylamine and aqueous ammonia, respectively at room temperature in the presence and absence of quaternary ammonium salt as a catalyst for different periods of time. The aminolysed and ammonolysed PET samples were investigated for the surface morphology with the help of scanning electron micrograph (SEM). It shows that the semi-crystalline PET waste samples reduce to monodisperse rods before fully degradation to the end products. The presence of the catalyst provides site for degradation of PET waste and enhances the rate of degradation. The SEM shows early developments of fissures in comparison to the one in absence of quaternary ammonium salt used as catalyst.

  4. Effect of mercury on the fish (Alburnus alburnus) chemoreceptor taste buds. A scanning electron microscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Pevzner, R.A.; Hernadi, L.; Salanki, J.

    1986-01-01

    Taste buds (TBS) were investigated by scanning electron microscopy on various parts of the oral cavity of the bleak. (Alburnus alburnus) after differently long exposures to mercury (300 ..mu..g/1 Hg/sup + +/). This low concentration of mercury did not result in lethal effect on the bleak even after 19 days long exposure, but produced morphological changes on the TBs, which showed duration dependency. The first sign of the morphological alteration on the TBs was observed after three days long exposure, when the microridge system of the epithelial cells became damaged and the mucus secretion increased on the apical surfaces of the TBs. On the TBs exposed for 10 days swollen microvilliar tips of the sensory cells could be observed besides the damage of the epithelial microridge system. On the TBs exposed for 19 days degenerative changes were detected on the microvilliar system of both the supporting and receptor cells. By this time completely degenerated TBs were frequently observed.

  5. The surface morphology of retinal breaks and lattice retinal degeneration. A scanning electron microscopic study.

    Science.gov (United States)

    Robinson, M R; Streeten, B W

    1986-02-01

    In 14 of 110 eye bank eyes, lesions characteristic of peripheral retinal surface pathology were examined by scanning electron microscopy (SEM). These included operculated and flap tears, trophic round holes, lattice degeneration with holes, and paravascular retinal "pitting" degeneration. By SEM, the edges of the retinal breaks were covered by smooth cellular membranes, merging peripherally with a meshwork of vitreous fibrils. The membrane cells had poorly defined borders, a pitted surface, and variable numbers of microvilli consistent with glia. Lattice surfaces and foci of paravascular retinal degeneration were covered by similar membrane, but showed characteristic differences. It appears that breaks in the internal limiting membrane always stimulate proliferation of preretinal glial membranes. Similar cellular morphology of the membranes associated with breaks is consistent with a common cell of origin. Limited proliferation of these membranes suggests that surface gliosis is normally inhibited when the cells contact either intact basement membrane or vitreous.

  6. [Electron microscopic study on the petechial hemorrhagic spots in patients with epidemic hemorrhage fever (EHF)].

    Science.gov (United States)

    Wang, S Q; Feng, M; Yang, L

    1994-12-01

    EHF viral particles were found in the squamous epithelial cells and capillary endothelial cells of the petechial spots located at the mucous membrane of the soft palate in cases of early stage of severe type EHF by transmission electron microscopy. The viral particles are round or oval in shape, about 100 nm in diameter with a lipid bilayer envelope from which spikes are protruding. The virions matured by budding through the intracytoplasmic membranes into the smooth surfaced vesicles. The morphological characteristics of the virion coincided with the viral particles of Family Bunyaviridae. It was the first time to demonstrate that the squamous epithelial cells of the soft palate is one of the target cells in EHF virus infection and to describe the subcellular morphological evidence of the petechial spots at the soft palate by EM.

  7. Exploring the environmental transmission electron microscope

    DEFF Research Database (Denmark)

    Wagner, Jakob B.; Cavalca, Filippo; Damsgaard, Christian D.

    2012-01-01

    of the opportunities that the environmental TEM (ETEM) offers when combined with other in situ techniques will be explored, directly in the microscope, by combining electron-based and photon-based techniques and phenomena. In addition, application of adjacent setups using sophisticated transfer methods...

  8. Cytoarchitecture of Caudiverbera caudiverbera stage VI oocytes: a light and electron microscope study.

    Science.gov (United States)

    Dabiké, M; Preller, A

    1999-06-01

    The general characteristics and salient features of the full-grown stage VI Caudiverbera caudiverbera oocyte at the light and electron microscopy level are described. The oocyte is a huge cell with radial symmetry and distinct polarity. A black animal hemisphere, rich in pigment granules and containing the nucleus, is clearly distinguished from the unpigmented white-yellowish vegetal hemisphere. The cell is surrounded by a highly invaginated plasma membrane, with numerous microvilli. The cortex underlying the plasma membrane contains cortical and pigment granules, mitochondria, rough endoplasmic reticulum and coated vesicles. Cytoskeletal components, such as actin filaments and microtubules, are also found in this region. The predominant structures, distributed throughout the cell, are the yolk platelets, which show a gradient in size with small platelets in the animal half and very large ones in the vegetal zone. Mitochondria are also very abundant in both hemispheres and clouds of these organelles are found in the perinuclear region, frequently associated with microtubules. Developed Golgi complexes are present in the cytoplasm and occasionally, annulate lamellae appear towards the inner zones. The nucleus is a large structure containing numerous nucleoli. The nuclear envelope is highly invaginated, especially at the side facing the vegetal pole. It is regularly perforated by large nuclear pores. Our results show that the structural organization of Caudiverbera oocytes, although similar to that of other amphibian oocytes, differs from them especially concerning the spatial distribution of several structural components.

  9. Encapsulated sensory corpuscle in the mucosa of human vocal cord: an electron microscope study.

    Science.gov (United States)

    Nagai, T

    1982-05-01

    Encapsulated sensory corpuscles of the Krause type were found in the mucosa of surgically removed human vocal cords. The corpuscles were ellipsoidal structures of about 30 to 50 micrometers and were located beneath the free edge in the mid-region along the intermembranous part. They contained a number of varicose nerve endings and lamellar cells. The lamellar cells had thin cytoplasmic lamellae which contained numerous cytoplasmic filaments and were interposed between the nerve endings. Attachment devices were frequently noted between the cytoplasmic lamellae and between the lamellae and nerve endings. Half-desmosomes were also noted along the plasma membrane of the lamellar cells. The intercellular space was filled with amorphous electron lucent material and contained a few collagen fibrils. Ladder-like filamentous structures were frequently encountered in the intercellular space. The location of the corpuscles at the free edge of the vocal cords suggests that the endings may receive the bilateral touch of the vibrating part of the cords in order to give sensory information for the control of the movement of the cords in phonation.

  10. An electron microscopic study of the photochemical cross-linking of DNA in guinea pig epidermis by psoralen derivatives

    International Nuclear Information System (INIS)

    Cech, T.; Pathak, M.A.; Biswas, R.K.

    1979-01-01

    Albino guinea pigs were treated with psoralen derivatives plus 320-400 nm ultraviolet radiation, and DNA was extracted from their epidermis. The DNA was assayed for the presence of interstrand cross-links by standard denaturation-renaturation assays and by a new technique, electron microscopy of the DNA under totally denaturing conditions. The latter method allows individual cross-links to be directly observed and counted. When either 4,5',8-trimethylpsoralen or 8-methoxypsoralen was applied topically to the skin (8-20 μg/cm 2 ) or administered orally (10-12 mg/kg body weight), followed by exposure to 320-400 nm ultraviolet radiation, most of the epidermal DNA was found to contain a high frequency of cross-links. For example, oral or topical trimethylpsoralen treatment gave an average of one cross-link per 250 nucleotide pairs or about 3 . 10 5 cross-links per guinea pig chromosome. When the dose of either drug was decreased 20-fold to the level used in the clinical treatment of psoriasis, however, no cross-links could be detected in the epidermal DNA. The electron microscopic assay is sensitive enough that one can put an upper limit of 1 cross-link per 10 6 nucleotide pairs (80 cross-links per chromosome) for the low dose studies. The significance of these findings to the understanding of the effectiveness of psoralens in psoriasis therapy is discussed. (Auth.)

  11. An electron microscopic studies of radiation effects on the enamel development of the rat molar

    International Nuclear Information System (INIS)

    Cho, Hyo Suck; Yoo, Dong Soo

    1995-01-01

    Mandibular first molars of the rats were undertaken to observe the radiosensitivity of amelogenesis. Twenty four Sprague-Dawley rats received 396cGy radiation with the MK Cell irradiator using Cs-137, and twenty four rats served as control. They were divided into two groups; Group 1 which received radiation at the 14th day after gestation and group 2 which received radiation at the 19th day after gestation. Light Microscopy and Transmitted Electron Microscopy investigation was undertaken in the group 1 at the 15th, 18th, 20th, 22nd (2 days after birth), and 25th day (5 days after birth) after gestation, and in the group Z at the 21th (birth day), 22nd (2 days after birth), and 25th (5 days after birth) day after gestation. The following histopathologic findings were obtained. 1. Compared with control group, experimental group showed a delayed formation of enamel and dentin due to slow rate of differentiation of undifferentiated mesenchymal cells. 2. In the experimental groups, the arrangement of the inner enamel epithelium was irregular and there were many vacuoles in the cytoplasm. There were dilated rER and mitochondria, increase of the intercellular space, and loss of the cellular polarity. 3. In the group 1, early enamel without Tomes' process, and early organic matrix was observed at the 25th day after gestation. 4. In the group 2, histopathologic changes were similar to those of the group 1, but the degree of changes was more severe than that of the group l.

  12. An electron microscopic studies of radiation effects on the enamel development of the rat molar

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyo Suck; Yoo, Dong Soo [Dept. of Oral and Maxillofacial Radiology, Graduate School, Seoul National University, Seoul (Korea, Republic of)

    1995-08-15

    Mandibular first molars of the rats were undertaken to observe the radiosensitivity of amelogenesis. Twenty four Sprague-Dawley rats received 396cGy radiation with the MK Cell irradiator using Cs-137, and twenty four rats served as control. They were divided into two groups; Group 1 which received radiation at the 14th day after gestation and group 2 which received radiation at the 19th day after gestation. Light Microscopy and Transmitted Electron Microscopy investigation was undertaken in the group 1 at the 15th, 18th, 20th, 22nd (2 days after birth), and 25th day (5 days after birth) after gestation, and in the group Z at the 21th (birth day), 22nd (2 days after birth), and 25th (5 days after birth) day after gestation. The following histopathologic findings were obtained. 1. Compared with control group, experimental group showed a delayed formation of enamel and dentin due to slow rate of differentiation of undifferentiated mesenchymal cells. 2. In the experimental groups, the arrangement of the inner enamel epithelium was irregular and there were many vacuoles in the cytoplasm. There were dilated rER and mitochondria, increase of the intercellular space, and loss of the cellular polarity. 3. In the group 1, early enamel without Tomes' process, and early organic matrix was observed at the 25th day after gestation. 4. In the group 2, histopathologic changes were similar to those of the group 1, but the degree of changes was more severe than that of the group l.

  13. Development of the Atomic-Resolution Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Gai, Pratibha L.; Boyes, Edward D.; Yoshida, Kenta

    2016-01-01

    The development of the novel atomic-resolution environmental transmission electron microscope (atomic-resolution ETEM) for directly probing dynamic gas–solid reactions in situ at the atomic level under controlled reaction conditions consisting of gas environment and elevated temperatures is descr......The development of the novel atomic-resolution environmental transmission electron microscope (atomic-resolution ETEM) for directly probing dynamic gas–solid reactions in situ at the atomic level under controlled reaction conditions consisting of gas environment and elevated temperatures...... is used to study steels, graphene, nanowires, etc. In this chapter, the experimental setup of the microscope column and its peripherals are described....

  14. Isotope analysis in the transmission electron microscope.

    Science.gov (United States)

    Susi, Toma; Hofer, Christoph; Argentero, Giacomo; Leuthner, Gregor T; Pennycook, Timothy J; Mangler, Clemens; Meyer, Jannik C; Kotakoski, Jani

    2016-10-10

    The Ångström-sized probe of the scanning transmission electron microscope can visualize and collect spectra from single atoms. This can unambiguously resolve the chemical structure of materials, but not their isotopic composition. Here we differentiate between two isotopes of the same element by quantifying how likely the energetic imaging electrons are to eject atoms. First, we measure the displacement probability in graphene grown from either 12 C or 13 C and describe the process using a quantum mechanical model of lattice vibrations coupled with density functional theory simulations. We then test our spatial resolution in a mixed sample by ejecting individual atoms from nanoscale areas spanning an interface region that is far from atomically sharp, mapping the isotope concentration with a precision better than 20%. Although we use a scanning instrument, our method may be applicable to any atomic resolution transmission electron microscope and to other low-dimensional materials.

  15. Using environmental transmission electron microscope to study the in-situ reduction of Co3O4 supported on α-Al2O3

    DEFF Research Database (Denmark)

    Dehghan-Niri, R.; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    in specialized Transmission Electron Microscope (TEM) instruments with differentially pumped columns at pressures in the range up to 20 mbar. 1-3 The objective of this work is to study the reduction of Co3O4 nanoparticles directly and observe their morphology and crystallography. The catalysts were produced...... by dispersion of crushed powder directly on steel grids and gold grids. TEM analysis was performed with an FEI TITAN E-cell electron microscope operating at 300 kV. Reduction was done at 360°C and 3.4 mbar H2 flow. The samples were studied before and after reduction by High Resolution TEM (HRTEM) imaging, high...

  16. An electron microscopic study of clinical Paget's disease of the nipple

    DEFF Research Database (Denmark)

    Jahn, H; Osther, P J; Nielsen, E H

    1995-01-01

    An ultrastructural study of the epidermis from eight patients with clinical Paget's disease of the nipple supports the epidermotropic theory. There was no evidence that the Paget's cells originated from keratinocytes. We propose the hypothesis that Paget's cells represent transformed ductal cells...

  17. An electron-microscope study of alpha to gamma transformation in an iron-nickel alloy

    Science.gov (United States)

    Lobodyuk, V. A.; Khandros, L. G.; Fedas, N. P.

    1980-01-01

    Procedures used to study the alpha to gamma conversion in thin foils of an iron alloy with 32% nickel concentration and initial martensite conversion temperature of -60 C are described. Photomicrographs show deformation twinning as well as changes in samples after they were heated. Reverse conversion is discussed and results are examined.

  18. Science 101: How Does an Electron Microscope Work?

    Science.gov (United States)

    Robertson, Bill

    2013-01-01

    Contrary to popular opinion, electron microscopes are not used to look at electrons. They are used to look for structure in things that are too small to observe with an optical microscope, or to obtain images that are magnified much more than is obtainable with an optical microscope. To understand how electron microscopes work, it will help to go…

  19. Influence of Electrical and Electromagnetic Stimulation on Nerve Regeneration in the Transected Mouse Sciatic Nerve : An Electron Microscopic Study

    OpenAIRE

    Ogata, Akiko; Matsumoto, Tomoko; Matsubara, Takako; Miki, Akinori

    2001-01-01

    Influence of electrical and electromagnetic stimulation on nerve regeneration was electron microscopically examined in the transected mouse sciatic nerve. Two days after the transection, several thin regenerating axons (daughter axons) were observed between the myelin sheath and basal lamina of Schwann cells in the proximal stump. Growth cones of the daughter axons contained several small round vesicles and mitochondria, and the shaft of them, neurofilaments, neurotubules and profiles of smoo...

  20. Radiosensitivity to gamma radiation of Escherichia coli in three different substracts and study of the alterations in the electronic microscope

    International Nuclear Information System (INIS)

    Cerri, M.E.N.F.

    1984-01-01

    The minimum inactivating dose of radiation (MID) for Escherichia coli IZ-1982 was determinated in three different substrates: cow milk, liquid extract of soybean and nutrient broth (DIFCO). Observations on electronic microscope of the bacterial cells were also made in the three substracts and submitted to different dose of gamma radiation. The Tukey's Test was used to stablish the significance of the difference in the size of the cells grow in the three substrates. (M.A.C.) [pt

  1. Freeze-fracture of infected plant leaves in ethanol for scanning electron microscopic study of fungal pathogens.

    Science.gov (United States)

    Moore, Jayma A; Payne, Scott A

    2012-01-01

    Fungi often are found within plant tissues where they cannot be visualized with the scanning electron microscope (SEM). We present a simple way to reveal cell interiors while avoiding many common causes of artifact. Freeze-fracture of leaf tissue using liquid nitrogen during the 100% ethanol step of the dehydration process just before critical point drying is useful in exposing intracellular fungi to the SEM.

  2. Scanning Electron Microscope Studies of Interactions between Agaricus bisporus (Lang) Sing Hyphae and Bacteria in Casing Soil

    OpenAIRE

    Masaphy, Segula; Levanon, D.; Tchelet, R.; Henis, Y.

    1987-01-01

    Relationships between the hyphae of Agaricus bisporus (Lang) Sing and bacteria from the mushroom bed casing layer were examined with a scanning electron microscope. Hyphae growing in the casing layer differed morphologically from compost-grown hyphae. Whereas the compost contained thin single hyphae surrounded by calcium oxalate crystals, the casing layer contained mainly wide hyphae or mycelial strands without crystals. The bacterial population in the hyphal environment consisted of several ...

  3. Scanning Electron Microscopic Study of the Lingual Papillae in the Anatolian Water Buffalo

    OpenAIRE

    Can, M; Atalgin, S. H

    2015-01-01

    The purpose of this study was to describe the surface structure of the lingual papillae in Anatolian Water Buffaloes using SEM. Six male Anatolian Water Buffaloes were used. Filiform, lentiform and conical papillae were determined three types as mechanical papillae. Fungiform and vallate papillae were observed two types as gustatory papillae on the tongue in Anatolian Water Buffalo. The filiform papillae were observed on the apex and body of the tongue, besides randomly identified lateral sur...

  4. Analytical electron microscope study of the omega phase transformation in a zirconium-niobium alloy

    International Nuclear Information System (INIS)

    Zaluzec, N.J.

    1979-01-01

    The study of the as-quenched omega phase morphology shows that the domain size of Zr-15% Nb is on the order of 30 A. No alignment of omega domains along β directions was observed and samples having undergone thermal cycling in thin foil form, did not develop a long-period structure of alternating β and ω phases below the omega transformation temperature

  5. Characteristic Study of the Al 6061 T-6 used in RTP Primary Cooling System Using Scanning Electron Microscope (SEM)

    International Nuclear Information System (INIS)

    Tonny Anak Lanyau; Yusof Abdullah; Tom, P.P.

    2011-01-01

    Reactor TRIGA PUSPATI (RTP) is the only nuclear research reactor in Malaysia. Since the first criticality on 28th June 1982, RTP has been going through the safe operation and well maintenance. Along the period of operation almost 30 years, some of the reactor system and component has been refurbished, upgraded and replaced to ensure the functionality and safety to the reactor itself as well as to protect personnel and environment. Primary cooling system is to provide the sufficient cooling to the reactor by removal of the heat generated in the reactor core through the heat transfer process in the heat exchanger. In 2009, RTP has been undergoing the primary cooling system upgrades. Primary cooling system components including aluminium pipes has been dismantled and replaced with the new system. As a part of the ageing management programme and radiation damage study, the disposed aluminum pipes were taken and used in this study. Scanning Electron Microscope (SEM) is used to study the surface topography and elemental composition in conjunction of energy dispersive x-ray spectroscopy analysis. This paper presents the study that has been conducted. (author)

  6. Transmission Electron Microscope Measures Lattice Parameters

    Science.gov (United States)

    Pike, William T.

    1996-01-01

    Convergent-beam microdiffraction (CBM) in thermionic-emission transmission electron microscope (TEM) is technique for measuring lattice parameters of nanometer-sized specimens of crystalline materials. Lattice parameters determined by use of CBM accurate to within few parts in thousand. Technique developed especially for use in quantifying lattice parameters, and thus strains, in epitaxial mismatched-crystal-lattice multilayer structures in multiple-quantum-well and other advanced semiconductor electronic devices. Ability to determine strains in indivdual layers contributes to understanding of novel electronic behaviors of devices.

  7. Ponderomotive phase plate for transmission electron microscopes

    Science.gov (United States)

    Reed, Bryan W [Livermore, CA

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  8. Descriptive, cytochemical and autoradiographic data on the paranucleolar mass. Electron microscopic study in several Lacertilians

    International Nuclear Information System (INIS)

    Hubert, Jean

    1975-01-01

    In several Lacertilians, a nuclear fibrillar area, called paranucleolar mass in previous works, is a constant cytological feature of germ cells and certain somatic cells. This nuclear area shows many similarities with the nuclear area called in different animals nuclear vacuole, paranucleolar vacuole or light area. The ultrastructure and development of the paranucleolar mass is described. The cytochemical study indicates that it is composed of proteins. The autoradiographic results show that it does not incorporate thymidine 3 H or uridine 3 H, which is in agreement with the lack of DNA and RNA proved with cytochemical procedures. It is rarely labelled with leucine 3 H. This last result which seems to be at variance with the proteinaceous nature of the paranucleolar mass is probably due to our short experimental periods in proportion to the long formation of the paranucleolar mass [fr

  9. An electron microscopic study of intraepithelial nerves of oral mucosa of rats during aging

    International Nuclear Information System (INIS)

    Choi, Dai Ho; You, Dong Soo

    1984-01-01

    Observation made in this study bring home salient features that may contribute towards a better understanding of the relationship between the available physiologic data and anatomical characteristics of those nerve fibers that penetrate into the intraepithelial space in the oral cavity. The present investigation characterized the fine structure of nerve fibers in oral mucosae with respect to the manner in which presumed sensory fibers enter into the intraepithelial space by penetration of the basal lamina. The conclusions were made little discernible qualitative difference exists between young and old animals, concerning the fine structural characteristics of nerve fibers and nerve endings and in old animals, significant reductions exist in the number of neural elements in the intraepithelial space.

  10. A scanning electron microscopic study of smear layer remaining following use of Greater Taper rotary instruments

    Directory of Open Access Journals (Sweden)

    S Soumya

    2011-01-01

    Full Text Available The aim of this in vitro study was to evaluate the smear layer in the root canal following the use of Ni-Ti hand ProTaper, HERO shaper and Twisted rotary instruments. Fifteen freshly extracted single rooted human mandibular premolar teeth were selected. Crowns of all teeth were cut off at the cemento-enamel junction with a carborundum disc. The roots were then randomly divided into three groups of 5 samples each. The working length of all teeth was established by the insertion of an endodontic instrument into the canal until its tip is visible at the apical foramen and then subtracted by 0.5 mm. A sequential crown down technique was carried out in all the three groups as follows: Group-I- Specimens in this group were instrumented with ProTaper Ni-Ti hand instruments. Group-II- Specimens were instrumented with HERO shapers. Group-III - The specimens in this group were instrumented with Twisted rotary instruments. Irrigation was done with 3% NaOCl and 15% EDTA in all the three groups. Teeth were carefully split with hammer and chisel and stored in small labeled bottles containing normal saline until SEM evaluation. Results showed that when comparing ProTaper files, Twisted rotary instruments and HERO shaper instruments, HERO shaper series of rotary instruments showed maximum amount of smear layer followed by the Twisted rotary instruments. Hand instruments produced least amount of smear layer.

  11. Matrix mineralogy of the Lance CO3 carbonaceous chondrite: A transmission electron microscope study

    International Nuclear Information System (INIS)

    Keller, L.P.; Buseck, P.R.

    1990-01-01

    The Lance CO3 carbonaceous chondrite (CC) is less altered than the CI and CM chondrites and so provides a view of the mineralogy and textures resulting from the earliest stages of aqueous alteration of CCs. Matrix olivine in Lance has been partly altered to fine-grained, Fe-bearing serpentine and poorly crystalline Fe 3+ oxide, a process that required both hydration and oxidation. Serpentine occurs as discrete packets separated from the olivine surfaces by the Fe 3+ oxide. The Fe released during the dissolution of olivine was partly incorporated into the serpentine; the remainder was oxidized to form Fe 3+ oxide. Matrix metal was also altered to produce Fe oxides, leaving the residual metal enriched in Ni. Olivine grains in Lance matrix contain channels along their [100] and [001] directions. The formation and convergence of such channels resulted in a grain-size reduction of the olivine. The alteration was pervasive but incomplete, suggesting a limited availability of fluid. A brief study of two other CO chondrites, Kainsaz and Warrenton, shows that these meteorites do not contain phyllosilicates in their matrices, although both contain Fe 3+ oxide between olivine grains. Prior to its alteration, Lance probably resembled Kainsaz, an unaltered CO3 chondrite. The alteration assemblage in Lance is only slightly different from that in Mokoia and essentially the same as that in C3 xenoliths from Murchison. Alteration products in Lance show greater similarities to CI than to CM chondrites

  12. Atmospheric scanning electron microscope for correlative microscopy.

    Science.gov (United States)

    Morrison, Ian E G; Dennison, Clare L; Nishiyama, Hidetoshi; Suga, Mitsuo; Sato, Chikara; Yarwood, Andrew; O'Toole, Peter J

    2012-01-01

    The JEOL ClairScope is the first truly correlative scanning electron and optical microscope. An inverted scanning electron microscope (SEM) column allows electron images of wet samples to be obtained in ambient conditions in a biological culture dish, via a silicon nitride film window in the base. A standard inverted optical microscope positioned above the dish holder can be used to take reflected light and epifluorescence images of the same sample, under atmospheric conditions that permit biochemical modifications. For SEM, the open dish allows successive staining operations to be performed without moving the holder. The standard optical color camera used for fluorescence imaging can be exchanged for a high-sensitivity monochrome camera to detect low-intensity fluorescence signals, and also cathodoluminescence emission from nanophosphor particles. If these particles are applied to the sample at a suitable density, they can greatly assist the task of perfecting the correlation between the optical and electron images. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Digital management of an electron microscope unit

    International Nuclear Information System (INIS)

    Elea, N.; Dickson, M.; Munroe, P.

    2002-01-01

    Full text: Electron microscope units, especially those such as ours, which operate as a central infrastructural facility are increasingly asked to provide more service, over more instruments with decreasing, or limited, financial resources. We believe that staff time is best used performing electron microscopy, assisting users and maintaining instrumentation rather than in the pursuit of red tape. One solution to this problem has been the creation of a control system which performs all routine acts of data management, such as the archiving and accessing of digital data, providing access to bookings, and most importantly in the era of user pays services, logging time and billing users. The system we have created, developed and expanded allows the users themselves to access our server through any web-browser and make their own bookings or access and manipulate their data. Users themselves must log on to a microscope through swipecard readers before it can be used and log-off after use. Their time is logged precisely and an exquisitely fair user pays systems can be operated by transferring logged usage time to spreadsheets to calculate charges. Furthermore, this system acts as a method of user authentication and can be used to bar incompetent or unauthorised users. The system has recently been upgraded to increase its utility to include sensors that monitor the electron microscope operating environment, such as magnetic field, room temperature, water flow etc, so that if these parameters depart significantly from optimum levels electron microscope unit staff may be alerted. In this presentation the structure of our system will be described and the advantages and disadvantages of such a system will be discussed. Copyright (2002) Australian Society for Electron Microscopy Inc

  14. Study of semiconductor valence plasmon line shapes via electron energy-loss spectroscopy in the transmission electron microscope

    International Nuclear Information System (INIS)

    Kundmann, M.K.

    1988-11-01

    Electron energy-loss spectra of the semiconductors Si, AlAs, GaAs, InAs, InP, and Ge are examined in detail in the regime of outer-shell and plasmon energy losses (0--100eV). Particular emphasis is placed on modeling and analyzing the shapes of the bulk valence plasmon lines. A line shape model based on early work by Froehlich is derived and compared to single-scattering probability distributions extracted from the measured spectra. Model and data are found to be in excellent agreement, thus pointing the way to systematic characterization of the plasmon component of EELS spectra. The model is applied to three separate investigations. 82 refs

  15. Electron spin resonance scanning tunneling microscope

    International Nuclear Information System (INIS)

    Guo Yang; Li Jianmei; Lu Xinghua

    2015-01-01

    It is highly expected that the future informatics will be based on the spins of individual electrons. The development of elementary information unit will eventually leads to novel single-molecule or single-atom devices based on electron spins; the quantum computer in the future can be constructed with single electron spins as the basic quantum bits. However, it is still a great challenge in detection and manipulation of a single electron spin, as well as its coherence and entanglement. As an ideal experimental tool for such tasks, the development of electron spin resonance scanning tunneling microscope (ESR-STM) has attracted great attention for decades. This paper briefly introduces the basic concept of ESR-STM. The development history of this instrument and recent progresses are reviewed. The underlying mechanism is explored and summarized. The challenges and possible solutions are discussed. Finally, the prospect of future direction and applications are presented. (authors)

  16. [A study of different polishing techniques for amalgams and glass-cermet cement by scanning electron microscope (SEM)].

    Science.gov (United States)

    Kakaboura, A; Vougiouklakis, G; Argiri, G

    1989-01-01

    Finishing and polishing an amalgam restoration, is considered as an important and necessary step of the restorative procedure. Various polishing techniques have been recommended to success a smooth amalgam surface. The aim of this study was to investigate the influence of three different polishing treatments on the marginal integrity and surface smoothness of restorations made of three commercially available amalgams and a glass-cermet cement. The materials used were the amalgams, Amalcap (Vivadent), Dispersalloy (Johnson and Johnson), Duralloy (Degussa) and the glass-cermet Katac-Silver (ESPE). The occlusal surfaces of the restorations were polished by the methods: I) round bur, No4-rubber cup-zinc oxide paste in a small brush, II) round bur No 4-bur-brown, green and super green (Shofu) polishing cups and points successively and III) amalgam polishing bur of 12-blades-smooth amalgam polishing bur. Photographs from unpolished and polished surfaces of the restorations, were taken with scanning electron microscope, to evaluate the polishing techniques. An improvement of marginal integrity and surface smoothness of all amalgam restorations was observed after the specimens had been polished with the three techniques. Method II, included Shofu polishers, proved the best results in comparison to the methods I and III. Polishing of glass-cermet cement was impossible with the examined techniques.

  17. Effect of fluoride and cobalt on forming enamel: scanning electron microscope and X-ray microanalysis study

    International Nuclear Information System (INIS)

    Ashrafi, S.H.; Eisenmann, D.R.; Zaki, A.E.; Liss, R.

    1988-01-01

    The forming surfaces of enamel of rat incisors were examined by scanning electron microscope one hour after injection of either 5 mg/100 g body weight of sodium fluoride or 12 mg/100 g body weight of cobalt chloride. The cell debris from the surfaces of the separated incisors was either gently wiped off with soft facial tissues or chemically removed by treating with NaOH, NaOCl or trypsin. Best results to remove cell debris were obtained from 0.25% trypsin treatment. SEM studies revealed that the surface of the normal secretory enamel was characteristic in appearance with well-developed smooth prism outlines. In fluoride specimens the prism outlines were feathery in appearance, laced with protruding spine-shaped clusters of mineral crystals. In the case of cobalt treatment, prism outlines were less uniform and in some areas they were incomplete. The calcium concentration of surface enamel was significantly lower in the cobalt-treated specimens than those from control and fluoride-treated animals. The Ca:Mg ratio was also lower in cobalt-treated specimens as compared to control and fluoride-treated ones

  18. Human teeth with periapical pathosis after overinstrumentation and overfilling of the root canals: a scanning electron microscopic study.

    Science.gov (United States)

    Gutiérrez, J H; Brizuela, C; Villota, E

    1999-01-01

    The aim of this study was to determine whether overinstrumentation followed by immediate overfilling could be a potential risk in the treatment of infected root canals. Thirty-five human teeth with infected root canals were overinstrumented and overfilled approximately 45 min after their extraction. The experimental teeth were enlarged up to size 40 and the overinstrumentation and overfilling were checked with the aid of a magnifying glass. The specimens were fixed in glutaraldehyde plus sodium cacodylate solution and prepared for scanning electron microscope examination. Bacteria were detected on the flute of the files and mostly at the root apices around the main foramen, remaining firmly attached to resorptive lacunae despite the fact that the apices had undergone great changes, including fracture or zipping. A control group consisting of 10 human teeth root canals containing vital pulps were also overinstrumented and overfilled. No bacteria were detected on the flutes of the files, at the apices or on the extruded master cone overfilling these samples. The high percentage of bacteria adhering to the resorptive lacunae or in the flutes of files used in overinstrumented human teeth with infected root canals carry a potential risk for postoperative pain, clinical discomfort and flare-ups. The hazards observed in these circumstances do not support the one-visit treatment of teeth having acute or chronic periapical abscesses.

  19. The effect of root surface conditioning on smear layer removal in periodontal regeneration (a scanning electron microscopic study)

    Science.gov (United States)

    Fidyawati, D.; Soeroso, Y.; Masulili, S. L. C.

    2017-08-01

    The role of root surface conditioning treatment on smear layer removal of human teeth is affected by periodontitis in periodontal regeneration. The objective of this study is to analyze the smear layer on root surface conditioned with 2.1% minocycline HCl ointment (Periocline), and 24% EDTA gel (Prefgel). A total of 10 human teeth indicated for extraction due to chronic periodontitis were collected and root planed. The teeth were sectioned in thirds of the cervical area, providing 30 samples that were divided into three groups - minocycline ointment treatment, 24% EDTA gel treatment, and saline as a control. The samples were examined by scanning electron microscope. No significant differences in levels of smear layer were observed between the minocycline group and the EDTA group (p=0.759). However, there were significant differences in the level of smear layer after root surface treatment in the minocycline and EDTA groups, compared with the control group (p=0.00). There was a relationship between root surface conditioning treatment and smear layer levels following root planing.

  20. An Electron Microscopic Study of the Irradiation Effects on the Striated Duct Cells of the Submandibular Gland in Rats

    International Nuclear Information System (INIS)

    Lee, Kyu Chan; Lee, Sang Rae

    1990-01-01

    The purpose of this study was to investigate the effects of irradiation on the striated duct cells of the rat submandibular gland ductal tissues which control the characteristics of saliva. For this study, the experimental group was composed of 36 irradiated Sprague Dawley strain rats divided into 8 subgroups- 1 hour, 2 hours, 3 hours, 6 hours, 12 hours, 24 hours, 48 hours, 72 hours after irradiation. 4 non-irradiated rats were used as the control group. The experimental animals were singly irradiated with a dose of 18 Gy gamma ray to their head and neck region by the Co-6-teletherapy unit and sacrificed after each experimental duration. The specimens were examined with a light microscope with an H-E stain and with a transmission electron microscope. The results of this study were as follows. 1. In the light micrograph, a severe atrophic change occurred in the striated duct cells at 2 hours after irradiation and gradual recovery occurred from 6 hours after irradiation. 2. The nuclear chromosomes of the striated duct cells were changed granular at 2 hours after irradiation. Recovery was observed at 6 hours after irradiation. Nuclear bodies were also observed from 3 hours after irradiation. 3. The mitochondria of the striated duct cells had indistinct cristae at 2 hours after irradiation, and were degenerated or swollen at 3 hours after irradiation. They recovered, however, from 6 hours, with an increasing number at 48 hours a regular arrangement was observed at 72 hours after irradiation. 4. The microvilli showed atrophic changes at 2 hours after irradiation and were almost lost at 3 hours after irradiation. They were observed again from 48 hours after irradiation. 5. The rough endoplasmic reticulum and golgi body were not apparent at 1 hours after irradiation and were dilated with degeneration 2 hours after, but intact rough endoplasmic reticulum were observed from 3 hours after irradiation and developed well at 24 hours after irradiation. By the result of this

  1. Examples of electrostatic electron optics: The Farrand and Elektros microscopes and electron mirrors

    International Nuclear Information System (INIS)

    Hawkes, P.W.

    2012-01-01

    The role of Gertrude Rempfer in the design of the Farrand and Elektros microscopes is evoked. The study of electron mirror optics, aberration correction using mirrors and the development of microscopes employing electron mirrors are recapitulated, accompanied by a full bibliography, of earlier publications in particular.

  2. French contributions to electron microscopic radioautography

    International Nuclear Information System (INIS)

    Droz, B.

    1994-01-01

    The radio autographic contributions carried out by electron microscopists took a part to improve the methodology and to extend applications to major biological problems. As underlined by CP Leblonc radioautography has clarified the importance of renewing systems; one may truly say that radioautography has introduced the time dimension in histology. The sites of biosynthesis of different substances have been located on the sub cellar scale, and it is now possible to analyse the molecular migrations within cells. The development of in situ hybridization and of receptors binding sites at the ultrastructural level has enlarged the application field of electron microscope radioautography. 64 refs., 2 figs

  3. A Comparative Evaluation of Adherence of Microorganism to Different Types of Brackets: A Scanning Electron Microscopic Study.

    Science.gov (United States)

    Shashidhar, E P; Sahitya, M; Sunil, T; Murthy, Anup R; Rani, M S

    2015-09-01

    The purpose of this study was to evaluate and compare the adherence of microorganism to different types of brackets using the scanning electron microscope (SEM). A double-blinded study was undertaken to evaluate and adherence of microorganisms to different types of brackets using SEM. At random, 12 patients reporting for treatment to the department of Orthodontics VS Dental College and Hospital were selected. Four types of brackets were included in the present study stainless steel, titanium, composite, and ceramic. Brackets were bonded to teeth of the patient on all the four quadrants. The teeth included for bonding were lateral incisor, canine, first premolar, and second premolar. The brackets were left for 72 h. After 72 h brackets were debonded, and they were evaluated by SEM for adherence of microorganism in the slot and tie wings surface. The SEM images were graded, and the adherence of microorganism to the brackets in the surfaces and the four different quadrants were recorded. There is a significant difference in adherence of microorganisms to the various types of brackets (P 0.05) included in the study. The interaction of bracket/surface, bracket/quadrant, surface/quadrants was analyzed, there was no significance of comparison of bracket/surfaces/quadrant but the interaction of bracket/quadrant was found to be significant (bracket/surfaces/quadrant was also found to be significant (bracket material and the least adherence of microorganisms was observed with the titanium bracket material. The adherence of microorganisms is relatively more in the slot area, when compare to the tie wings surface maximum adherence of microorganism is observed in the upper left quadrant and least adherence of microorganism is observed in the lower right quadrant. There is a significant difference in adherence of microorganisms to various types of brackets and the surfaces included in the study. There is no significant difference in the adherence of microorganism to the bracket

  4. Electron microscopic studies on experimental skin cancer after combination treatment with X-ray, hematoporphyrin oligomer and caffeine

    International Nuclear Information System (INIS)

    Ueda, Keiichi; Ishiguro, Kazumori; Takaishi, Kimiko; Hatcho, Masahiro; Nakagawa, Shigemori

    1992-01-01

    The effect of combination treatment with X-ray, hematoporphyrin oligomer (HpO) and caffeine (Caf) was compared electron microscopically with that of a single use of these treatments. In experimental skin cancer, ultrastructural changes of nuclei and cytoplasm of tumor cells after combination treatment with HpO, X-ray and Caf showed more remarkable changes than in single X-ray irradiation and in HpO and X-ray irradiation. It is concluded that the combination treatment of HpO, X-ray and Caf is useful to the skin cancers in clinical practice. (author)

  5. Scanning Electron Microscope Studies of Interactions between Agaricus bisporus (Lang) Sing Hyphae and Bacteria in Casing Soil

    Science.gov (United States)

    Masaphy, Segula; Levanon, D.; Tchelet, R.; Henis, Y.

    1987-01-01

    Relationships between the hyphae of Agaricus bisporus (Lang) Sing and bacteria from the mushroom bed casing layer were examined with a scanning electron microscope. Hyphae growing in the casing layer differed morphologically from compost-grown hyphae. Whereas the compost contained thin single hyphae surrounded by calcium oxalate crystals, the casing layer contained mainly wide hyphae or mycelial strands without crystals. The bacterial population in the hyphal environment consisted of several types, some attached to the hyphae with filamentlike structures. This attachment may be important in stimulation of pinhead initiation. Images PMID:16347340

  6. Electron microscopic studies on experimental skin cancer after combination treatment with X-ray, hematoporphyrin oligomer and caffeine

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Keiichi; Ishiguro, Kazumori; Takaishi, Kimiko; Hatcho, Masahiro; Nakagawa, Shigemori (Fukui Medical School, Matsuoka (Japan))

    1992-05-01

    The effect of combination treatment with X-ray, hematoporphyrin oligomer (HpO) and caffeine (Caf) was compared electron microscopically with that of a single use of these treatments. In experimental skin cancer, ultrastructural changes of nuclei and cytoplasm of tumor cells after combination treatment with HpO, X-ray and Caf showed more remarkable changes than in single X-ray irradiation and in HpO and X-ray irradiation. It is concluded that the combination treatment of HpO, X-ray and Caf is useful to the skin cancers in clinical practice. (author).

  7. Scanning electron microscopic study of the otolithic organs in the bichir (Polypterus bichir) and shovel-nose sturgeon (Scaphirhynchus platorynchus).

    Science.gov (United States)

    Popper, A N

    1978-09-01

    The anatomy and ultrastructure of the sacculus, lagena, and utriculus of the ear of Polypterus bichir and Scaphirhynchus platorynchus were studied using the scanning electron microscope. The otolithic organs each contain a single dense calcareous otolith in close contact with a sensory epithelium (macula). The maculae have sensory hair cells typical of those found in other vertebrates, surrounded by microvilli-covered supporting cells. The hair cells on each macula are divided into several groups, with all of the cells in each group morphologically polarized in the same direction. The cells of the utricular macula in both species are divided into opposing groups in a pattern similar to that found in other vertebrates. The saccular and lagenar maculae are located in a single large chamber in both species. In Scaphirhychus the two maculae are on the same plane, while in Polypterus they are at right angles to one another. The hair cells on the saccular maculae of both species are divided into two oppositely oriented groups. In Scaphirhynchus the cells on the posterior half of the macula are oriented dorsally on the dorsal half of the macula and ventrally on the ventral half. The anterior region of the macula is rotated and the cells of the dorsal and ventral groups are shifted so that they are oriented on the animal's horizon plane. A similar pattern is found in Polypterus, except that this macula is shaped like a "J" with the vertical portion of the J having horizontal cells and the bottom portion vertical cells. The lagenar maculae in both species have dorsally oriented cells on the anterior side of the macula and ventrally oriented cells on the posterior half of the macula. While these data are not sufficient for clarifying the taxonomic relationship between the two species studied, it is clear that the ears in these species have a number of significant differences from the teleost ear that could have functional and/or taxonomic significance.

  8. Electron microscope autoradiography of isolated DNA molecules

    International Nuclear Information System (INIS)

    Delain, Etienne; Bouteille, Michel

    1980-01-01

    Autoradiographs of 3 H-thymidine-labelled DNA molecules were observed with an electron microscope. After ten months of exposure significant labelling was obtained with tritiated T7 DNA molecules which had a specific activity of 630,000 cpm/μg. Although isolated DNA molecules were not stretched out to such an extent that they could be rigorously compared to straight 'hot lines', the resolution was estimated and found to be similar to that obtained by autoradiography on thin plastic sections. The H.D. value was of the order of 1600A. From the known specific activity of the macromolecules, it was possible to compare the expected number of disintegrations from the samples to the number of grains obtained on the autoradiograms. This enabled us to calculate 1/ The absolute autoradiographic efficiency and 2/ The per cent ratio of thymidine residues labelled with tritium. These results throw some light on the resolution and sensitivity of electron microscope autoradiography of shadowed isolated macromolecules as compared to thin plastic sections

  9. Microscopic properties of degradation-free capped GdN thin films studied by electron spin resonance

    International Nuclear Information System (INIS)

    Shimokawa, Tokuro; Fukuoka, Yohei; Fujisawa, Masashi; Zhang, Weimin; Okubo, Susumu; Ohta, Hitoshi; Sakurai, Takahiro; Vidyasagar, Reddithota; Yoshitomi, Hiroaki; Kitayama, Shinya; Kita, Takashi

    2015-01-01

    The microscopic magnetic properties of high-quality GdN thin films have been investigated by electron spin resonance (ESR) and ferromagnetic resonance (FMR) measurements. Detailed temperature dependence ESR measurements have shown the existence of two ferromagnetic components at lower temperatures, which was not clear from the previous magnetization measurements. The temperature, where the resonance shift occurs for the major ferromagnetic component, seems to be consistent with the Curie temperature obtained from the previous magnetization measurement. On the other hand, the divergence of line width is observed around 57 K for the minor ferromagnetic component. The magnetic anisotropies of GdN thin films have been obtained by the analysis of FMR angular dependence observed at 4.2 K. Combining the X-ray diffraction results, the correlation between the magnetic anisotropies and the lattice constants is discussed

  10. In-situ deformation studies of an aluminum metal-matrix composite in a scanning electron microscope

    Science.gov (United States)

    Manoharan, M.; Lewandowski, J. J.

    1989-01-01

    Tensile specimens made of a metal-matrix composite (cast and extruded aluminum alloy-based matrix reinforced with Al2O3 particulate) were tested in situ in a scanning electron microscope equipped with a deformation stage, to directly monitor the crack propagation phenomenon. The in situ SEM observations revealed the presence of microcracks both ahead of and near the crack-tip region. The microcracks were primarily associated with cracks in the alumina particles. The results suggest that a region of intense deformation exists ahead of the crack and corresponds to the region of microcracking. As the crack progresses, a region of plastically deformed material and associated microcracks remains in the wake of the crack.

  11. Coupling auto trophic in vitro plant cultivation system to scanning electron microscope to study plant-fungal interactions

    Energy Technology Data Exchange (ETDEWEB)

    Jaeger, N. de; Decock, C.; Declereck, S.; Providencia, I. E. de la

    2010-07-01

    The interactions of plants with pathogens and beneficial micro-organisms have been seldom compared on the same host and under strict controlled auto trophic in vitro culture conditions. Here, the life cycle of two plant beneficial (Glomus sp. MUCL 41833 and Trichoderma harzianum) and one plant pathogen (Rhizoctonia solani) fungi were described on potato (Solanum tuberosum) plantlets under auto trophic in vitro culture conditions using video camera imaging and the scanning electron microscope (SEM). (i) The colony developmental pattern of the extraradical mycelium within the substrate, (ii) the reproduction structures and (iii) the three-dimensional spatial arrangements of the fungal hyphae within the potato root cells were successfully visualized, monitored and described. The combination of the autotrophic in vitro culture system and SEM represent a powerful tool for improving our knowledge on the dynamics of plant-fungal interactions. (Author) 41 refs.

  12. The case study on elemental analyses of Asian dust particles by using an analytical scanning electron microscope

    International Nuclear Information System (INIS)

    Takeuchi, Jo; Masaki, Kazushige; Emoto, Yuji

    2009-01-01

    The individual particle analyses of suspended particulate matter (SPM: particles less than 10 μm in size) collected on tape filters during April 17-18, 2006, in Kawasaki, Japan, were carried out. The chemical elements present in aerosol particles were investigated by using a scanning electron microscope with an energy-dispersive X-ray spectrometer. The fraction of chemical elements detected in the particles collected on April 18, 2006, except for S, was in good agreement with that in Asian dust particles from the Loess Plateau, China. S was not detected in Asian dust particles but was detected in the particles collected on April 18, 2006. Therefore, it was concluded that the particles collected in April 18, 2006, in Kawasaki were Asian dust particles transported from the Asian continent, and the absorption of SO 2 or the coagulation of sulfate occurred during the transportation of Asian dust particles. (author)

  13. Cathodoluminescence in the scanning transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kociak, M., E-mail: mathieu.kociak@u-psud.fr [Laboratoire de Physique des Solides, Université Paris-SudParis-Sud, CNRS-UMR 8502, Orsay 91405 (France); Zagonel, L.F. [“Gleb Wataghin” Institute of Physics University of Campinas - UNICAMP, 13083-859 Campinas, São Paulo (Brazil)

    2017-05-15

    Cathodoluminescence (CL) is a powerful tool for the investigation of optical properties of materials. In recent years, its combination with scanning transmission electron microscopy (STEM) has demonstrated great success in unveiling new physics in the field of plasmonics and quantum emitters. Most of these results were not imaginable even twenty years ago, due to conceptual and technical limitations. The purpose of this review is to present the recent advances that broke these limitations, and the new possibilities offered by the modern STEM-CL technique. We first introduce the different STEM-CL operating modes and the technical specificities in STEM-CL instrumentation. Two main classes of optical excitations, namely the coherent one (typically plasmons) and the incoherent one (typically light emission from quantum emitters) are investigated with STEM-CL. For these two main classes, we describe both the physics of light production under electron beam irradiation and the physical basis for interpreting STEM-CL experiments. We then compare STEM-CL with its better known sister techniques: scanning electron microscope CL, photoluminescence, and electron energy-loss spectroscopy. We finish by comprehensively reviewing recent STEM-CL applications. - Highlights: • Reviews the field of STEM-CL. • Introduces the technical requirements and challenges for STEM-CL. • Introduces the different types of excitations probed by STEM-CL. • Gives comprehensive overview of the last fifteenth years in the field.

  14. Scanning electron microscopic evaluation of efficacy of 17% Ethylenediaminetetraacetic acid and chitosan for smear layer removal with ultrasonics: An In vitro study

    Directory of Open Access Journals (Sweden)

    Aradhana Babu Kamble

    2017-01-01

    Full Text Available Introduction: The main aim of root canal treatment is cleaning, shaping and then obturating three dimensionally to prevent reinfection. This includes chemicomechanical cleansing by instrumentation and the use of irrigating solutions. Therefore, the purpose of this study was to compare the smear layer removal from root canal dentine subjected to two root canal irrigants, 17% EDTA and 0.2% Chitosan, a new irrigant using Scanning Electron Microscope. Methodology: 40 single rooted premolars were decoronated followed by instrumentation with I Race files and intermediate irrigation with 3% sodium hypochlorite and activation with ultrasonics. Then the samples were longitudinally sectioned and place in the respective test solutions and their controls for 5 minutes. Scanning Electron Microscopic evaluation was further carried out. Results: The results of the present study indicates that the Chitosan which was proved effective in removing smear layer. Conclusion: A moderate concentration of 0.2% chitosan removes the smear layer with greater efficiency.

  15. Three-Dimensional Orientation Mapping in the Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Liu, Haihua; Schmidt, Søren; Poulsen, Henning Friis

    2011-01-01

    resolution of 200 nanometers (nm). We describe here a nondestructive technique that enables 3D orientation mapping in the transmission electron microscope of mono- and multiphase nanocrystalline materials with a spatial resolution reaching 1 nm. We demonstrate the technique by an experimental study...

  16. Heat- and radiation-resistant scintillator for electron microscopes

    International Nuclear Information System (INIS)

    Kosov, A.V.; Petrov, S.A.; Puzyr', A.P.; Chetvergov, N.A.

    1987-01-01

    The use of a scintillator consisting of a single crystal of bismuth orthogermanate, which has high heat and radiation resistance, in REM-100, REM-200, and REM-100U electron microscopes is described. A study of the heat and radiation stabilities of single crystals of bismuth orthogermanate (Bi 4 Ge 3 O 12 ) has shown that they withstood multiple electron-beam heating redness (T ∼ 800 0 C) without changes in their properties

  17. Comparison of cross-sectional transmission electron microscope studies of thin germanium epilayers grown on differently oriented silicon wafers.

    Science.gov (United States)

    Norris, D J; Myronov, M; Leadley, D R; Walther, T

    2017-12-01

    We compare transmission electron microscopical analyses of the onset of islanding in the germanium-on-silicon (Ge/Si) system for three different Si substrate orientations: (001), (11¯0) and (11¯1)Si. The Ge was deposited by reduced pressure chemical vapour deposition and forms islands on the surface of all Si wafers; however, the morphology (aspect ratio) of the deposited islands is different for each type of wafer. Moreover, the mechanism for strain relaxation is different for each type of wafer owing to the different orientation of the (111) slip planes with the growth surface. Ge grown on (001)Si is initially pseudomorphically strained, yielding small, almost symmetrical islands of high aspect ratio (clusters or domes) on top interdiffused SiGe pedestals, without any evidence of plastic relaxation by dislocations, which would nucleate later-on when the islands might have coalesced and then the Matthews-Blakeslee limit is reached. For (11¯0)Si, islands are flatter and more asymmetric, and this is correlated with plastic relaxation of some islands by dislocations. In the case of growth on (11¯1)Si wafers, there is evidence of immediate strain relaxation taking place by numerous dislocations and also twinning. In the case of untwined film/substrate interfaces, Burgers circuits drawn around certain (amorphous-like) regions show a nonclosure with an edge-type a/4[1¯12] Burgers vector component visible in projection along [110]. Microtwins of multiples of half unit cells in thickness have been observed which occur at the growth interface between the Si(11¯1) buffer layer and the overlying Ge material. Models of the growth mechanisms to explain the interfacial configurations of each type of wafer are suggested. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  18. Helium leak testing of scanning electron microscope

    International Nuclear Information System (INIS)

    Ahmad, Anis; Tripathi, S.K.; Mukherjee, D.

    2015-01-01

    Scanning Electron Microscope (SEM) is a specialized electron-optical device which is used for imaging of miniscule features on topography of material specimens. Conventional SEMs used finely focused high energy (about 30 KeV) electron beam probes of diameter of about 10nm for imaging of solid conducting specimens. Vacuum of the order of 10"-"5 Torr is prerequisite for conventional Tungsten filament type SEMs. One such SEM was received from one of our laboratory in BARC with a major leak owing to persisting poor vacuum condition despite continuous pumping for several hours. He-Leak Detection of the SEM was carried out at AFD using vacuum spray Technique and various potential leak joints numbering more than fifty were helium leak tested. The major leak was detected in the TMP damper bellow. The part was later replaced and the repeat helium leak testing of the system was carried out using vacuum spray technique. The vacuum in SEM is achieved is better than 10"-"5 torr and system is now working satisfactorily. (author)

  19. Using an Electron Scanning Microscope to Assess the Penetrating Abilities of an Experimental Preparation with Features of a Dental Infiltrant: Preliminary Study.

    Science.gov (United States)

    Skucha-Nowak, Małgorzata; Mertas, Anna; Tanasiewicz, Marta

    2016-01-01

    The resin infiltration technique is one of the micro-invasive methods whose aim is the penetration of demineralized enamel with a low viscosity resin. This technique allows the dentist to avoid the application of mechanical means of treatment. The objective of this preliminary study was to attempt to determine the possibilities of using an electron microscope to assess the penetrating abilities of an experimental preparation with features of a dental infiltrant and to compare the depth of infiltration of the designed experimental preparation with an infiltrant available on the market. A bioactive methacrylate monomer based on PMMAn with built-in metronidazole was synthesized. The commercially available Icon solution (with contrast agent YbF3) and the experimental solution were applied to the relevant parts of teeth. The dissected sections along the long tooth axis and polished surfaces were then examined with use of an electron scanning microscope. The backscattered electron technique gives much better results than the secondary electron method as it makes it possible to localize even very small YbF3 particles. The authors concluded that the backscattered electron technique gives much better results than the secondary electron method as it makes it possible to localize even very small particles of the contrast agent. In order to prevent blockage of decalcified enamel tissue by ytterbium trifluoride (YbF3) grains, a nanoparticle form of that compound should be used (that is, particles with sizes in the range of 10-9 m).

  20. Electron microscopic studies of natural gas oxidation catalyst – Effects of thermally accelerated aging on catalyst microstructure

    DEFF Research Database (Denmark)

    Honkanen, Mari; Hansen, Thomas Willum; Jiang, Hua

    2017-01-01

    Structural changes of PtPd nanoparticles in a natural gas oxidation catalyst were studied at elevated temperatures in air and low-oxygen conditions and in situ using environmental transmission electron microscopy (ETEM). The fresh catalyst shows

  1. Nitrogen implantation with a scanning electron microscope.

    Science.gov (United States)

    Becker, S; Raatz, N; Jankuhn, St; John, R; Meijer, J

    2018-01-08

    Established techniques for ion implantation rely on technically advanced and costly machines like particle accelerators that only few research groups possess. We report here about a new and surprisingly simple ion implantation method that is based upon a widespread laboratory instrument: The scanning electron microscope. We show that it can be utilized to ionize atoms and molecules from the restgas by collisions with electrons of the beam and subsequently accelerate and implant them into an insulating sample by the effect of a potential building up at the sample surface. Our method is demonstrated by the implantation of nitrogen ions into diamond and their subsequent conversion to nitrogen vacancy centres which can be easily measured by fluorescence confocal microscopy. To provide evidence that the observed centres are truly generated in the way we describe, we supplied a 98% isotopically enriched 15 N gas to the chamber, whose natural abundance is very low. By employing the method of optically detected magnetic resonance, we were thus able to verify that the investigated centres are actually created from the 15 N isotopes. We also show that this method is compatible with lithography techniques using e-beam resist, as demonstrated by the implantation of lines using PMMA.

  2. Development of olfactory epithelium and associated structures in the green iguana, Iguana iguana—light and scanning electron microscopic study

    Directory of Open Access Journals (Sweden)

    Olga Sapoznikov

    2016-12-01

    Full Text Available The ontogenesis of the nasal cavity has been described in many mammalian species. The situation is different with reptiles, despite the fact that they have become relatively common as pets. In this study we focused on the ontogenesis of the olfactory epithelium, as well as other types of epithelia in the nasal cavity of pre-hatched green iguanas (Iguana iguana. Collection of samples began from day 67 of incubation and continued every four days until hatching. Microscopic examination revealed that significant morphological changes in the nasal cavity began approximately at day 91 of ontogenesis. Approximately at this same stage, the nasal cavity epithelium began to differentiate. The cavity was divided into two compartments by a cartilaginous disc. The ventral compartment bulged rostrally and eventually opened up into the external environment. Three clearly demarcated areas of epithelium in the nasal cavity were visible at day 107.

  3. Development of olfactory epithelium and associated structures in the green iguana, Iguana iguana-light and scanning electron microscopic study.

    Science.gov (United States)

    Sapoznikov, Olga; Cizek, Petr; Tichy, Frantisek

    2016-01-01

    The ontogenesis of the nasal cavity has been described in many mammalian species. The situation is different with reptiles, despite the fact that they have become relatively common as pets. In this study we focused on the ontogenesis of the olfactory epithelium, as well as other types of epithelia in the nasal cavity of pre-hatched green iguanas ( Iguana iguana ). Collection of samples began from day 67 of incubation and continued every four days until hatching. Microscopic examination revealed that significant morphological changes in the nasal cavity began approximately at day 91 of ontogenesis. Approximately at this same stage, the nasal cavity epithelium began to differentiate. The cavity was divided into two compartments by a cartilaginous disc. The ventral compartment bulged rostrally and eventually opened up into the external environment. Three clearly demarcated areas of epithelium in the nasal cavity were visible at day 107.

  4. Development of olfactory epithelium and associated structures in the green iguana, Iguana iguana—light and scanning electron microscopic study

    Science.gov (United States)

    Cizek, Petr; Tichy, Frantisek

    2016-01-01

    The ontogenesis of the nasal cavity has been described in many mammalian species. The situation is different with reptiles, despite the fact that they have become relatively common as pets. In this study we focused on the ontogenesis of the olfactory epithelium, as well as other types of epithelia in the nasal cavity of pre-hatched green iguanas (Iguana iguana). Collection of samples began from day 67 of incubation and continued every four days until hatching. Microscopic examination revealed that significant morphological changes in the nasal cavity began approximately at day 91 of ontogenesis. Approximately at this same stage, the nasal cavity epithelium began to differentiate. The cavity was divided into two compartments by a cartilaginous disc. The ventral compartment bulged rostrally and eventually opened up into the external environment. Three clearly demarcated areas of epithelium in the nasal cavity were visible at day 107. PMID:27920949

  5. The radiation-induced topotactic conversion of di-para anthracene to anthracene: an electron microscopic study

    International Nuclear Information System (INIS)

    Parkinson, G.M.; Goringe, M.J.; Thomas, J.M.

    1977-01-01

    A study was made of single crystals of di-para anthracene, the product of photodimerisation of anthracene. This undergoes an electron-induced topotactic conversion to anthracene, and the study of this reaction using low temperature TEM enabled the identification of separate stages in the conversion and the elucidation of probable mechanistic routes. (author)

  6. Collaborative Research and Development. Delivery Order 0006: Transmission Electron Microscope Image Modeling and Semiconductor Heterointerface Characterization

    National Research Council Canada - National Science Library

    Mahalingam, Krishnamurthy

    2006-01-01

    .... Transmission electron microscope (TEM) characterization studies were performed on a variety of novel III-V semiconductor heterostructures being developed for advanced optoelectronic device applications...

  7. Use of a scanning electron microscope for examining radioactive materials

    International Nuclear Information System (INIS)

    Kauffmann, Yves; Prouve, Michel.

    1981-05-01

    The LAMA laboratory of the Grenoble Nuclear Research Center participates in studies carried out by research teams on fuels. Post-irradiation studies are performed on irradiated pins for research and development and safety programs. A scanning electron microscope was acquired for this purpose. This microscope had to fulfill certain criteria: it had to be sufficiently compact for it to be housed in a lead enclosure; it had to be capable of being adapted to operate with remote handling control. The modifications made to this microscope are briefly described together with the ancillary equipment of the cell. In parallel with these operations, an interconnection was realized enabling materials to be transferred between the various sampling and sample preparation cells and the microscope cell with a small transfer cask. After two years operating experience the microscope performance has been assessed satisfactory. The specific radioactivity of the samples themselves cannot be incriminated as the only cause of loss in resolution at magnifications greater than x 10,000 [fr

  8. Static structure, microscopic dynamics and electronic properties of the liquid Bi–Li alloy. An ab initio molecular dynamics study

    International Nuclear Information System (INIS)

    Souto, J; Alemany, M M G; Gallego, L J; González, L E; González, D J

    2013-01-01

    We report an ab initio molecular dynamics study of the static, dynamic and electronic properties of the liquid Bi x Li 1−x alloy, which is a complex binary system with a marked tendency to heterocoordination. The calculated total static structure factors are in good agreement with the available experimental data. The partial dynamic structure factors exhibit side peaks indicative of propagating density fluctuations, and for some concentrations we have found a density fluctuation mode with phase velocity greater than the hydrodynamic sound velocity. We have also evaluated other dynamical properties such as the diffusion coefficients, the shear viscosity and the adiabatic sound velocity. The electronic density of states show that the liquid Bi x Li 1−x alloy has a metallic character, although with strong deviations from the free-electron parabolic curve. The results reported improve the understanding of binary liquid alloys with both fast and slow propagating collective modes. (paper)

  9. A sub-cm micromachined electron microscope

    Science.gov (United States)

    Feinerman, A. D.; Crewe, D. A.; Perng, D. C.; Shoaf, S. E.; Crewe, A. V.

    1993-01-01

    A new approach for fabricating macroscopic (approximately 10x10x10 mm(exp 3)) structures with micron accuracy has been developed. This approach combines the precision of semiconductor processing and fiber optic technologies. A (100) silicon wafer is anisotropically etched to create four orthogonal v-grooves and an aperture on each 10x12 mm die. Precision 308 micron optical fibers are sandwiched between the die to align the v-grooves. The fiber is then anodically bonded to the die above and below it. This procedure is repeated to create thick structures and a stack of 5 or 6 die will be used to create a miniature scanning electron microscope (MSEM). Two die in the structure will have a segmented electrode to deflect the beam and correct for astigmatism. The entire structure is UHV compatible. The performance of an SEM improves as its length is reduced and a sub-cm 2 keV MSEM with a field emission source should have approximately 1 nm resolution. A low voltage high resolution MSEM would be useful for the examination of biological specimens and semiconductors with a minimum of damage. The first MSEM will be tested with existing 6 micron thermionic sources. In the future a micromachined field emission source will be used. The stacking technology presented in this paper can produce an array of MSEMs 1 to 30 mm in length with a 1 mm or larger period. A key question being addressed by this research is the optimum size for a low voltage MSEM which will be determined by the required spatial resolution, field of view, and working distance.

  10. The trajectories of secondary electrons in the scanning electron microscope.

    Science.gov (United States)

    Konvalina, Ivo; Müllerová, Ilona

    2006-01-01

    Three-dimensional simulations of the trajectories of secondary electrons (SE) in the scanning electron microscope have been performed for plenty of real configurations of the specimen chamber, including all its basic components. The primary purpose was to evaluate the collection efficiency of the Everhart-Thornley detector of SE and to reveal fundamental rules for tailoring the set-ups in which efficient signal acquisition can be expected. Intuitive realizations about the easiness of attracting the SEs towards the biased front grid of the detector have shown themselves likely as false, and all grounded objects in the chamber have been proven to influence the spatial distribution of the signal-extracting field. The role of the magnetic field penetrating from inside the objective lens is shown to play an ambiguous role regarding possible support for the signal collection.

  11. Pulsed Power for a Dynamic Transmission Electron Microscope

    Energy Technology Data Exchange (ETDEWEB)

    dehope, w j; browning, n; campbell, g; cook, e; king, w; lagrange, t; reed, b; stuart, b; Shuttlesworth, R; Pyke, B

    2009-06-25

    Lawrence Livermore National Laboratory (LLNL) has converted a commercial 200kV transmission electron microscope (TEM) into an ultrafast, nanoscale diagnostic tool for material science studies. The resulting Dynamic Transmission Electron Microscope (DTEM) has provided a unique tool for the study of material phase transitions, reaction front analyses, and other studies in the fields of chemistry, materials science, and biology. The TEM's thermionic electron emission source was replaced with a fast photocathode and a laser beam path was provided for ultraviolet surface illumination. The resulting photoelectron beam gives downstream images of 2 and 20 ns exposure times at 100 and 10 nm spatial resolution. A separate laser, used as a pump pulse, is used to heat, ignite, or shock samples while the photocathode electron pulses, carefully time-synchronized with the pump, function as probe in fast transient studies. The device functions in both imaging and diffraction modes. A laser upgrade is underway to make arbitrary cathode pulse trains of variable pulse width of 10-1000 ns. Along with a fast e-beam deflection scheme, a 'movie mode' capability will be added to this unique diagnostic tool. This talk will review conventional electron microscopy and its limitations, discuss the development and capabilities of DTEM, in particularly addressing the prime and pulsed power considerations in the design and fabrication of the DTEM, and conclude with the presentation of a deflector and solid-state pulser design for Movie-Mode DTEM.

  12. Pulsed Power for a Dynamic Transmission Electron Microscope

    International Nuclear Information System (INIS)

    DeHope, W.J.; Browning, N.; Campbell, G.; Cook, E.; King, W.; Lagrange, T.; Reed, B.; Stuart, B.; Shuttlesworth, R.; Pyke, B.

    2009-01-01

    Lawrence Livermore National Laboratory (LLNL) has converted a commercial 200kV transmission electron microscope (TEM) into an ultrafast, nanoscale diagnostic tool for material science studies. The resulting Dynamic Transmission Electron Microscope (DTEM) has provided a unique tool for the study of material phase transitions, reaction front analyses, and other studies in the fields of chemistry, materials science, and biology. The TEM's thermionic electron emission source was replaced with a fast photocathode and a laser beam path was provided for ultraviolet surface illumination. The resulting photoelectron beam gives downstream images of 2 and 20 ns exposure times at 100 and 10 nm spatial resolution. A separate laser, used as a pump pulse, is used to heat, ignite, or shock samples while the photocathode electron pulses, carefully time-synchronized with the pump, function as probe in fast transient studies. The device functions in both imaging and diffraction modes. A laser upgrade is underway to make arbitrary cathode pulse trains of variable pulse width of 10-1000 ns. Along with a fast e-beam deflection scheme, a 'movie mode' capability will be added to this unique diagnostic tool. This talk will review conventional electron microscopy and its limitations, discuss the development and capabilities of DTEM, in particularly addressing the prime and pulsed power considerations in the design and fabrication of the DTEM, and conclude with the presentation of a deflector and solid-state pulser design for Movie-Mode DTEM

  13. Root planing with Er:YAG laser X Gracey curette, a study in vitro in scanning electron microscopic study

    International Nuclear Information System (INIS)

    Mello, Fabiano Augusto Sfier de

    2000-01-01

    The Er:YAG laser has been studied as a periodontal therapies, used to remove subgingival calculus and its bactericidal effects. The proposal of this study is to evaluate the effectiveness of the Er:YAG laser in root planing in comparison to the traditional method, not surgical. Six recently extracted due to the disease periodontal, were cut longitudinally, tends like this two half of the root. These half were separate in four groups. The first group is the natural tooth (group controls negative), the second group (group controls) was accomplished to root planing with Gracey curette. And in the third to Er:YAG laser with a contact tip, using a 45 deg angle in relation to the root; in the fourth group was scraped and planned with Er:YAG laser and complemented root planing with Gracey curette. The used energy was of 100 mJ (out put) and the frequency of 10 Hz accomplished with irrigation. The obtained results were similar in the groups 2 and 3 in comparison to the amount of smear-layer. In group 4 however, better result was obtained, because the image (SEM) was much more regular and with less amount of smear-layer. The conclusion of the work is that with the association of the laser technique and Gracey curette the results are superior to the conventional treatment. (author)

  14. Association of 239Pu with lysosomes in rat, Syrian hamster, and Chinese hamster liver as studied by carrier-free electrophoresis and electron microscopic autoradiography with 241Pu

    International Nuclear Information System (INIS)

    Seidel, A.; Krueger, E.W.; Wiener, M.; Hotz, G.; Balani, M.; Thies, W.G.

    1985-01-01

    The binding of injected monomeric plutonium in the liver of rats, Syrian hamsters, and Chinese hamsters (species which show profound differences in their ability to eliminate 239 Pu from the liver) was investigated by carrier-free electrophoresis using 239 Pu and electron microscopic autoradiography with 241 Pu. These studies are part of a program designed to obtain a better understanding of the mechanisms of the clearance of transuranium elements from liver of different mammals and man. Between 4 and 9 days after nuclide injection, a clear correlation between the majority of the 239 Pu and lysosomal enzymes was observed when the mitochondrial-lysosomal (ML) fraction of the livers was analyzed by carrier-free electrophoresis. In the two hamster species, a second 239 Pu peak exists from the beginning and increases with time to comprise 50% of the total radioactivity at later times. During electron microscopic examination 4 days after 241 Pu injection, beta tracks were frequently observed over globular structures resembling dense bodies in Chinese hamster liver. They were also observed frequently over chromatin-rich portions of the cell nuclei. These results, together with those from previous density gradient studies, show that lysosomes are the primary deposition site for 239 Pu in the liver cytoplasm of these three rodent species. The hypothesis of a morphologic transformation of these lysosomes with time in hamster liver and of rapid bulk exocytosis of the lysosomes in rats are still possible explanations for the extreme differences in the elimination among the three species

  15. Transmission electron microscope studies of phase transitions in single crystals and ceramics of ferroelectric Pb(Sc1/2Ta1/2)O3

    International Nuclear Information System (INIS)

    Baba-Kishi, K.Z.; Barber, D.J.

    1990-01-01

    An account is given of transmission electron microscope investigations of the phase transitions in single crystals and ceramics of the complex perovskite-structured ferroelectric 'relaxor' compound Pb(Sc 1/2 Ta 1/2 )O 3 . The crystal symmetries pertaining to both the non-polar paraelectric (PE) and polar ferroelectric (FE) states have been studied by the technique of convergent-beam electron diffraction. A new phase transition has been discovered in the temperature range for which the FE and PE states coexist. The new phase transition is interpreted as the creation of a modulated antiferroelectric state, and this is viewed as marking a departure from relaxor behaviour towards more 'normal' ferroelectric behaviour. (orig.)

  16. Interstitial cells of Cajal and Auerbach's plexus. A scanning electron microscopical study of guinea-pig small intestine

    DEFF Research Database (Denmark)

    Jessen, Harry; Thuneberg, Lars

    1991-01-01

    Anatomy, interstitial cells of Cajal, myenteric plexus, small intestine, guinea-pig, scanning electron microscopy......Anatomy, interstitial cells of Cajal, myenteric plexus, small intestine, guinea-pig, scanning electron microscopy...

  17. The sinusoidal lining cells in "normal" human liver. A scanning electron microscopic investigation

    DEFF Research Database (Denmark)

    Horn, T; Henriksen, Jens Henrik Sahl; Christoffersen, P

    1986-01-01

    The scanning electron microscopic was used to study the fenestrations of human liver sinusoids. Thirteen biopsies, where light microscopy and transmission electron microscopy revealed normal sinusoidal architecture, were investigated. The number of fenestrae was calculated in acinar zone 3...

  18. Fine structure and synaptic organization of the mesencephalic trigeminal nucleus of the cat: a quantitative electron microscopic study.

    Science.gov (United States)

    Lazarov, N

    1996-01-01

    The ultrastructure and synaptic organization of the mesencephalic trigeminal nucleus (MTN) were studied in adult cats by transmission electron microscopy and more precisely quantified with an automated image analysis system. Two subpopulations of MTN neurons were identified within the nucleus: large spherical or ovoid (pseudo)unipolar cells amounted to about 60% of the total population that resemble typical primary sensory neurons and small multipolar neurons (estimated 40%), some of which are possibly interneurons. By electron microscopy, most neurons in the MTN proved to have a rich cytoplasm in the perikaryon with abundant rough endoplasmic reticulum, a large number of free ribosomes and polysomes, also well-developed Golgi complex, and numerous mitochondria and neurofilaments indicating a high rate of protein synthesis and axonal transport in these cells. Three types of synaptic contacts were observed in the MTN: axodendritic, axosomatic and axospinic of both symmetric and asymmetric morphology. Most of them (almost 90%) were axodendritic and axodendritic spine. Approximately 70% of axon terminals contained small round vesicles (S-type boutons) whereas the other 30% belonged to the P-type boutons filled with a pleomorphic vesicle population. Axosomatic synapses were comparatively rare accounting for 10% of the total. About two-third of them were of S-type and almost 25% of the remaining third were F-type in which flat synaptic vesicles could be seen, and less than 10% were P- and G-types with granular vesicles.

  19. In vivo and in vitro effects of imidacloprid on sheep keds (Melophagus ovinus): a light and electron microscopic study.

    Science.gov (United States)

    Mehlhorn, H; D'Haese, J; Mencke, N; Hansen, O

    2001-04-01

    The effects of imidacloprid (Advantage) on sheep keds (Melophagus ovinus Linne 1758) were studied in vivo and in vitro by means of direct observation (monitored on video tape) and by light and electron microscopy. It was found that: 1. Imidacloprid acted rapidly on all motile stages of the sheep keds. Within 3-4 min after exposure they became immobile and their legs and the abdomen started tetanic trembling movements for 15-30 min, leading to death. 2. The compound is apparently taken up by the body, since it also acted on those sheep keds that had been exclusively exposed to imidacloprid-contaminated filter papers. 3. The compound is available and active for more than 1 month in the wool of sheep; even rainfall does not reduce its efficacy. Body contact between treated mother sheep and their lambs protects them from infestation with these ectoparasites. 4. The compound initiates an ultimately lethal destruction of the ganglia, nerve chords and related muscle fibers, as can be seen in electron micrographs.

  20. An electron microscope for the aberration-corrected era

    Energy Technology Data Exchange (ETDEWEB)

    Krivanek, O.L. [Nion Co., 1102 8th Street, Kirkland, WA 98033 (United States)], E-mail: krivanek.ondrej@gmail.com; Corbin, G.J.; Dellby, N.; Elston, B.F.; Keyse, R.J.; Murfitt, M.F.; Own, C.S.; Szilagyi, Z.S.; Woodruff, J.W. [Nion Co., 1102 8th Street, Kirkland, WA 98033 (United States)

    2008-02-15

    Improved resolution made possible by aberration correction has greatly increased the demands on the performance of all parts of high-end electron microscopes. In order to meet these demands, we have designed and built an entirely new scanning transmission electron microscope (STEM). The microscope includes a flexible illumination system that allows the properties of its probe to be changed on-the-fly, a third-generation aberration corrector which corrects all geometric aberrations up to fifth order, an ultra-responsive yet stable five-axis sample stage, and a flexible configuration of optimized detectors. The microscope features many innovations, such as a modular column assembled from building blocks that can be stacked in almost any order, in situ storage and cleaning facilities for up to five samples, computer-controlled loading of samples into the column, and self-diagnosing electronics. The microscope construction is described, and examples of its capabilities are shown.

  1. An electron microscope for the aberration-corrected era

    International Nuclear Information System (INIS)

    Krivanek, O.L.; Corbin, G.J.; Dellby, N.; Elston, B.F.; Keyse, R.J.; Murfitt, M.F.; Own, C.S.; Szilagyi, Z.S.; Woodruff, J.W.

    2008-01-01

    Improved resolution made possible by aberration correction has greatly increased the demands on the performance of all parts of high-end electron microscopes. In order to meet these demands, we have designed and built an entirely new scanning transmission electron microscope (STEM). The microscope includes a flexible illumination system that allows the properties of its probe to be changed on-the-fly, a third-generation aberration corrector which corrects all geometric aberrations up to fifth order, an ultra-responsive yet stable five-axis sample stage, and a flexible configuration of optimized detectors. The microscope features many innovations, such as a modular column assembled from building blocks that can be stacked in almost any order, in situ storage and cleaning facilities for up to five samples, computer-controlled loading of samples into the column, and self-diagnosing electronics. The microscope construction is described, and examples of its capabilities are shown

  2. Sporulation of Bacillus sphaericus 2297: an electron microscope study of crystal-like inclusion biogenesis and toxicity to mosquito larvae.

    Science.gov (United States)

    Kalfon, A; Charles, J F; Bourgouin, C; de Barjac, H

    1984-04-01

    Sporulation of Bacillus sphaericus strain 2297 in a synchronous liquid culture was studied by electron microscopy. The t0 of sporulation occurred 7 h after the beginning of the lag phase. Crystal-like inclusions first appeared at t2 and reached their final size between t5 and t6. The release of the spore/inclusion complex occurred at about t15 (22 h after inoculation). Toxicity against Culex pipiens larvae was related to sporulation and appeared during the early stages of sporulation. The LC50 (24 h) decreased about 10(5)-fold between t0-2 and t7, in correlation with the formation of crystalline inclusions. Heat resistance of spores appeared later than toxicity.

  3. Electron microscopic study on macrogametogenesis of Eimeria labbeana infecting the Egyptian wild doves and host-parasite relationship.

    Science.gov (United States)

    Bashtar, A R; Abdel-Ghaffar, F A; Ahmed, A K

    1991-04-01

    The development of macrogametes of Eimeria labbeana was studied by electron microscopy in the epithelial cells of the villi at 96 hrs. post-infection. Appearance of young macrogamonts was characterized by the loss of the architecture of the apicomplexa (polar ring, rhoptries, micronemes, conoid, subpellicular microtubules), while the pellicle became only one unit membrane. This was associated by the formation of wall forming bodies II then I. Moreover, the mitochondria, endoplasmic reticulum and Golgi were increased in the cytoplasm. Amylopectin granules as well as lipid globules were greatly increased in mature macrogametes. Host cell reaction due to infection included enlargement and deformation of infected cells, hypertrophy of their nuclei, swollen and degeneration of mitochondria, endoplasmic reticulum and vacuolation of ground cytoplasm. These changes occur in both cells with and without parasite.

  4. Microscopic Electron Dynamics in Metal Nanoparticles for Photovoltaic Systems

    Directory of Open Access Journals (Sweden)

    Katarzyna Kluczyk

    2018-06-01

    Full Text Available Nanoparticles—regularly patterned or randomly dispersed—are a key ingredient for emerging technologies in photonics. Of particular interest are scattering and field enhancement effects of metal nanoparticles for energy harvesting and converting systems. An often neglected aspect in the modeling of nanoparticles are light interaction effects at the ultimate nanoscale beyond classical electrodynamics. Those arise from microscopic electron dynamics in confined systems, the accelerated motion in the plasmon oscillation and the quantum nature of the free electron gas in metals, such as Coulomb repulsion and electron diffusion. We give a detailed account on free electron phenomena in metal nanoparticles and discuss analytic expressions stemming from microscopic (Random Phase Approximation—RPA and semi-classical (hydrodynamic theories. These can be incorporated into standard computational schemes to produce more reliable results on the optical properties of metal nanoparticles. We combine these solutions into a single framework and study systematically their joint impact on isolated Au, Ag, and Al nanoparticles as well as dimer structures. The spectral position of the plasmon resonance and its broadening as well as local field enhancement show an intriguing dependence on the particle size due to the relevance of additional damping channels.

  5. Electron optical characteristics of a concave electrostatic electron mirror for a scanning electron microscope

    International Nuclear Information System (INIS)

    Hamarat, R.T.; Witzani, J.; Hoerl, E.M.

    1984-08-01

    Numerical computer calculations are used to explore the design characteristics of a concave electrostatic electron mirror for a mirror attachment for a conventional scanning electron microscope or an instrument designed totally as a scanning electron mirror microscope. The electron paths of a number of set-ups are calculated and drawn graphically in order to find the optimum shape and dimensions of the mirror geometry. This optimum configuration turns out to be the transition configuration between two cases of electron path deflection, towards the optical axis of the system and away from it. (Author)

  6. Field electron emission spectrometer combined with field ion/electron microscope as a field emission laboratory

    International Nuclear Information System (INIS)

    Shkuratov, S.I.; Ivanov, S.N.; Shilimanov, S.N.

    1996-01-01

    The facility, combining the field ion microscope, field electron emission microscope and field electron emission spectrometer, is described. Combination of three methodologies makes it possible to carry out the complete cycle of emission studies. Atom-plane and clean surface of the studied samples is prepared by means of field evaporation of the material atom layers without any thermal and radiation impact. This enables the study of atom and electron structure of clean surface of the wide range materials, the study whereof through the field emission methods was previously rather difficult. The temperature of the samples under study changes from 75 up to 2500 K. The energy resolution of the electron analyzer equals 30 MeV. 19 refs., 10 figs

  7. Imaging differential polarization microscope with electronic readout

    International Nuclear Information System (INIS)

    Mickols, W.; Tinoco, I.; Katz, J.E.; Maestre, M.F.; Bustamante, C.

    1985-01-01

    A differential polarization microscope forms two images: one of the transmitted intensity and the other due to the change in intensity between images formed when different polarizations of light are used. The interpretation of these images for linear dichroism and circular dichroism are described. The design constraints on the data acquisition systems and the polarization modulation are described. The advantage of imaging several biological systems which contain optically anisotropic structures are described

  8. Application of Digital (Motic and Scanning electron microscope in histological study of leaf of Tecoma gaudichaudi DC (Bignoniaceae

    Directory of Open Access Journals (Sweden)

    Kedar Kalyani Abhimanyu

    2016-03-01

    Full Text Available Tecoma gaudichaudi DC (Bignoniaceae is a shrub or a small tree found in various regions of Maharashtra. The objective of the study was to develop various standardization parameters for the evaluation of leaves of this plant. Microscopy, powder characteristics and scanning electron microscopy (SEM of leaves were observed and results were recorded. Histological study of leaves shows underlined palisade cells on the upper epidermal surface, anomocytic stomata on the lower epidermis with covering (2–3 cells and glandular trichomes etc. The specific observed characteristics such as types of stomata and trichomes were predominantly observed on the lower epidermal surface of the leaf. Physicochemical analysis such as extractive value includes petroleum ether, ethanol, ethyl acetate and aqueous soluble extractive values of 3.08, 10.50, 8.5, and 13.4% w/w respectively; extracts were analysed by chemical test and showed presence of flavonoids, tannins, steroids and triterpenoids etc. Fluorescence analysis is one of the parameters that help in the analysis of chemical constituents. So these parameters are useful in the authentication of T. gaudichaudi DC and can play a vital role in authentication and standardization of botanicals.

  9. Electron microscopic study of the myelinated nerve fibres and the perineurial cell basement membrane in the diabetic human peripheral nerves

    International Nuclear Information System (INIS)

    ElBarrany, Wagih G.; Hamdy, Raid M.; AlHayani, Abdulmonem A.; Jalalah, Sawsan M.

    2009-01-01

    To study the quantitative and ultrastructural changes in myelinated nerve fibers and the basement membranes of the perineurial cells in diabetic nerves. The study was performed at the Department of Anatomy, Faculty of Medicine, King Abdul-Aziz University, Jeddah, Saudi Arabia from 2003 to 2005. Human sural nerves were obtained from 15 lower limbs and 5 diabetic nerve biopsies. The total mean and density of myelinated nerve fibers per fascicle were calculated, with density of microtubules and mitochondria in the axoplasm. The number of the perineurial cell basement membrane layers was counted, and thickness of the basement membrane was measured. Among the 15 diabetic and 5 normal human sural nerves, the average diameters, number and surface area of myelinated nerve fibers and axonal microtubules density were found to be less in diabetic nerves. Mitochondrial density was higher in diabetic axons. Thickness of the perineurial cell basement membrane had a greater mean, but the number of perineurial cell layers was less than that of the diabetic group. The inner cellular layer of the perineurium of the diabetic nerves contained large vacuoles containing electron-dense degenerated myelin. A few specimens showed degenerated myelinated nerve fibers, while others showed recovering ones. Retracted axoplasms were encountered with albumin extravasation. Diabetes caused an increase in perineurial permeability. The diabetic sural nerve showed marked decrease in the myelinated nerve fibres, increase degenerated mitochondria, and decreased microtubules. (author)

  10. Transmission electron microscope study of fusion-environment radiation damage in iron and iron-chromium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Horton, L.L.S.

    1982-07-01

    A transmission electron microscopy study of radiation damage microstructures in iron and iron-chromium alloys has been performed. This study consisted of both qualitative and quantitative characterization of the dislocation and cavity microstructures, including determination of vacancy/interstitial character and Burgers vectors for dislocation loops and analysis of the cavity morphology. The effects of irradiation temperature, fluence, helium implantation, and chromium content were investigated. Neutron irradiation (iron specimens, 1 dpa, 455 to 1000 K) and triple-beam ion irradiation (Fe-10% Cr specimens, 10 dpa, 725 to 950 K; Fe-10% Cr specimens, 850 K, 0.3 to 100 dpa; and Fe, Fe-5% Cr, Fe-10% Cr specimens, 850 K, 10 dpa) were employed. In the triple-beam ion irradiation procedure, simultaneous bombardment with 4 MeV Fe/sup + +/ ions and energetic He/sup +/ and D/sub 2//sup +/ ions was used to simulate the fusion environment (10 at. ppM He/dpa and 41 at. ppM D/dpa). In addition, single-beam 4 MeV Fe/sup + +/ ion irradiations of Fe-10% Cr both with and without pre-injection of helium and deuterium were performed.

  11. Transmission electron microscope study of fusion-environment radiation damage in iron and iron-chromium alloys

    International Nuclear Information System (INIS)

    Horton, L.L.S.

    1982-07-01

    A transmission electron microscopy study of radiation damage microstructures in iron and iron-chromium alloys has been performed. This study consisted of both qualitative and quantitative characterization of the dislocation and cavity microstructures, including determination of vacancy/interstitial character and Burgers vectors for dislocation loops and analysis of the cavity morphology. The effects of irradiation temperature, fluence, helium implantation, and chromium content were investigated. Neutron irradiation (iron specimens, 1 dpa, 455 to 1000 K) and triple-beam ion irradiation (Fe-10% Cr specimens, 10 dpa, 725 to 950 K; Fe-10% Cr specimens, 850 K, 0.3 to 100 dpa; and Fe, Fe-5% Cr, Fe-10% Cr specimens, 850 K, 10 dpa) were employed. In the triple-beam ion irradiation procedure, simultaneous bombardment with 4 MeV Fe ++ ions and energetic He + and D 2 + ions was used to simulate the fusion environment (10 at. ppM He/dpa and 41 at. ppM D/dpa). In addition, single-beam 4 MeV Fe ++ ion irradiations of Fe-10% Cr both with and without pre-injection of helium and deuterium were performed

  12. Scanning electron microscopic study of the tongue in golden-headed lion tamarins, Leontopithecus chrysomelas (Callithrichidae: Primates

    Directory of Open Access Journals (Sweden)

    Carlos Henrique de F. Burity

    2009-06-01

    Full Text Available Leontopithecus is the largest genus of Callithrichidae, occupying isolated remnants of the Atlantic Forest in Brazil. The objective of this study was to investigate the ultrastructure of the dorsum of the tongue of golden-headed lion tamarins. Tongues of ten adult lion tamarins kept in captivity at the Center of Primatology of Rio de Janeiro (CPRJ-FEEMA were analyzed under scanning electron microscopy. The three vallate papillae were distributed in a V shape, and each papilla was surrounded by a deep sulcus and an external pad; the medial papilla showed a round shape and the lateral one was elliptical. The filiform papillae were shaped as a crown or as finger-like papillae, and were distributed throughout the tongue, including the margins, except for the posterior region. The fungiform papillae were scattered among the filiform papillae, in a disperse manner, from the apex to the lateral vallate papillae. The foliate papillae had a typical ultrastructure, with folds that ranged in number from 1 to 3. With respect to vallate papillae, we identified the microridge and pore pattern on its surface. Further studies are required to confirm the hypotheses on the ultrastructural aspects described for golden-headed lion tamarins.

  13. Visualization of atomic distances at the 1MV electron microscope: first results obtained on the Grenoble 1MV microscope

    International Nuclear Information System (INIS)

    Bourret, A.

    1975-01-01

    Practical and theoretical conditions for obtaining high resolution lattice images are presented. The use of a high voltage electron microscope is particularly powerful to visualize distances smaller than 3A. A 2A resolution test on (200) gold planes has been carried out on the Grenoble 1MV microscope. It would be possible at this level to study the crystalline defects such as dislocations or grain boundaries [fr

  14. Transient Hypothyroidism During Lactation Arrests Myelination in the Anterior Commissure of Rats. A Magnetic Resonance Image and Electron Microscope Study.

    Science.gov (United States)

    Lucia, Federico S; Pacheco-Torres, Jesús; González-Granero, Susana; Canals, Santiago; Obregón, María-Jesús; García-Verdugo, José M; Berbel, Pere

    2018-01-01

    Thyroid hormone deficiency at early postnatal ages affects the cytoarchitecture and function of neocortical and telencephalic limbic areas, leading to impaired associative memory and in a wide spectrum of neurological and mental diseases. Neocortical areas project interhemispheric axons mostly through the corpus callosum and to a lesser extent through the anterior commissure (AC), while limbic areas mostly project through the AC and hippocampal commissures. Functional magnetic resonance data from children with late diagnosed congenital hypothyroidism and abnormal verbal memory processing, suggest altered ipsilateral and contralateral telencephalic connections. Gestational hypothyroidism affects AC development but the possible effect of transient and chronic postnatal hypothyroidism, as occurs in late diagnosed neonates with congenital hypothyroidism and in children growing up in iodine deficient areas, still remains unknown. We studied AC development using in vivo magnetic resonance imaging and electron microscopy in hypothyroid and control male rats. Four groups of methimazole (MMI) treated rats were studied. One group was MMI-treated from postnatal day (P) 0 to P21; some of these rats were also treated with L-thyroxine (T4) from P15 to P21, as a model for early transient hypothyroidism. Other rats were MMI-treated from P0 to P150 and from embryonic day (E) 10 to P170, as a chronic hypothyroidism group. The results were compared with age paired control rats. The normalized T2 signal using magnetic resonance image was higher in MMI-treated rats and correlated with the number and percentage of myelinated axons. Using electron microscopy, we observed decreased myelinated axon number and density in transient and chronic hypothyroid rats at P150, unmyelinated axon number increased slightly in chronic hypothyroid rats. In MMI-treated rats, the myelinated axon g-ratio and conduction velocity was similar to control rats, but with a decrease in conduction delays. These

  15. Transient Hypothyroidism During Lactation Arrests Myelination in the Anterior Commissure of Rats. A Magnetic Resonance Image and Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Federico S. Lucia

    2018-04-01

    Full Text Available Thyroid hormone deficiency at early postnatal ages affects the cytoarchitecture and function of neocortical and telencephalic limbic areas, leading to impaired associative memory and in a wide spectrum of neurological and mental diseases. Neocortical areas project interhemispheric axons mostly through the corpus callosum and to a lesser extent through the anterior commissure (AC, while limbic areas mostly project through the AC and hippocampal commissures. Functional magnetic resonance data from children with late diagnosed congenital hypothyroidism and abnormal verbal memory processing, suggest altered ipsilateral and contralateral telencephalic connections. Gestational hypothyroidism affects AC development but the possible effect of transient and chronic postnatal hypothyroidism, as occurs in late diagnosed neonates with congenital hypothyroidism and in children growing up in iodine deficient areas, still remains unknown. We studied AC development using in vivo magnetic resonance imaging and electron microscopy in hypothyroid and control male rats. Four groups of methimazole (MMI treated rats were studied. One group was MMI-treated from postnatal day (P 0 to P21; some of these rats were also treated with L-thyroxine (T4 from P15 to P21, as a model for early transient hypothyroidism. Other rats were MMI-treated from P0 to P150 and from embryonic day (E 10 to P170, as a chronic hypothyroidism group. The results were compared with age paired control rats. The normalized T2 signal using magnetic resonance image was higher in MMI-treated rats and correlated with the number and percentage of myelinated axons. Using electron microscopy, we observed decreased myelinated axon number and density in transient and chronic hypothyroid rats at P150, unmyelinated axon number increased slightly in chronic hypothyroid rats. In MMI-treated rats, the myelinated axon g-ratio and conduction velocity was similar to control rats, but with a decrease in conduction

  16. Quantitative methods for the analysis of electron microscope images

    DEFF Research Database (Denmark)

    Skands, Peter Ulrik Vallø

    1996-01-01

    The topic of this thesis is an general introduction to quantitative methods for the analysis of digital microscope images. The images presented are primarily been acquired from Scanning Electron Microscopes (SEM) and interfermeter microscopes (IFM). The topic is approached though several examples...... foundation of the thesis fall in the areas of: 1) Mathematical Morphology; 2) Distance transforms and applications; and 3) Fractal geometry. Image analysis opens in general the possibility of a quantitative and statistical well founded measurement of digital microscope images. Herein lies also the conditions...

  17. Scanning electron microscopic evaluation of root canal surfaces ...

    African Journals Online (AJOL)

    Scanning electron microscopic evaluation of root canal surfaces prepared with three rotary endodontic systems: Lightspeed, ProTaper and EndoWave. ... fracture with LightSpeed (LS), ProTaper (PT) and EndoWave (Ew) rotary instruments.

  18. Synthesis, Spectral Characterization, Electron Microscopic Study and Influence on the Thermal Stability of Phosphorus-containing Dendrimer with a 4,4'-Sulphonyldiphenol at the Core

    International Nuclear Information System (INIS)

    Dadapeer, Echchukattula; Rasheed, Syed; Raju, Chamarthi Naga

    2011-01-01

    The divergent synthesis of novel phosphorus-containing dendrimer with 4,4'-sulphonyldiphenol at the core has been accomplished involving simple condensation reactions using P(O)Cl 3 , P(S)Cl 3 , 3-amino-phenol, 3-hydroxy-benzaldehyde, and 2-butyn 1, 4-diol. The final compound was a Schiff's base macromolecule possessing 4 imine bonds, 8 acetylenic bonds and 8 OH groups at the periphery. The structures of intermediate compounds were confirmed by IR, NMR ( 1 H, 13 C and 31 P), LC-Mass and C, H, N analysis. The structure of the final dendrimer was confirmed by IR, NMR ( 1 H, 13 C and 31 P), MALDI-TOF-MS, and C, H, N analysis. The surface morphological characteristics of the final dendrimer were understood by Scanning Electronic Microscopic study (SEM). The thermal stability of the final dendrimer was studied by TGA/DTA analysis

  19. Atomic-resolution studies of In2O3-ZnO compounds on aberration-corrected electron microscopes

    International Nuclear Information System (INIS)

    Yu, Wentao

    2009-01-01

    In this work, the characteristic inversion domain microstructures of In 2 O 3 (ZnO) m (m=30) compounds were investigated by TEM methods. At bright-atom contrast condition, atomically resolved HR-TEM images of In 2 O 3 (ZnO) 30 were successfully acquired in [1 anti 100] zone axis of ZnO, with projected metal columns of ∝1.6 A well resolved. From contrast maxima in the TEM images, local lattice distortions at the pyramidal inversion domain boundaries were observed for the first time. Lattice displacements and the strain field in two-dimensions were visualized and measured using the 'DALI' algorithm. Atomically resolved single shot and focal series images of In 2 O 3 (ZnO) 30 were achieved in both zone axes of ZnO, [1 anti 100] and [2 anti 1 anti 10], respectively. The electron waves at the exit-plane were successfully reconstructed using the software package 'TrueImage'. Finally, a three dimensional atomic structure model for the pyramidal IDB was proposed, with an In distribution of 10%, 20%, 40%, 20% and 10% of In contents over 5 atom columns along basal planes, respectively. Through a detailed structural study of In 2 O 3 (ZnO) m compounds by using phase-contrast and Z-contrast imaging at atomic resolution, In 3+ atoms are determined with trigonal bi-pyramidal co-ordination and are distributed at the pyramidal IDBs. (orig.)

  20. High-resolution electron-microscopic studies of the polymorphs in Ag2±δSe films

    International Nuclear Information System (INIS)

    Okabe, Toshio; Ura, Katsuhiko

    1994-01-01

    The polymorphs that appear in the low-temperature phase of silver selenide have been studied by high-resolution electron microscopy. The specimen films are intentionally prepared with excess silver or selenium over stoichiometric composition by flash evaporation, as-depositing carbon films on both sides of the specimen films to protect them from selenium sublimation and to maintain the composition throughout the heat treatment. It is shown that four different types of low-temperature phase exist: tetragonal (a = 6.98, c = 4.96 A) for a metastable phase only formed with a small grain size of less than 50 nm; face-centred cubic (a = 10.9 A) for a non-stoichiometric phase with excess silver; monoclinic (a = 7.05, b = 8.17, c = 4.34 A, α = 101.0 ) for a non-stoichiometric phase with excess selenium; and orthorhombic (a = 7.05, b 7.82, c = 4.34 A) for the stoichiometric stable phase. The topotactic relations between the orthorhombic and monoclinic types are found to be fully coherent, having the same a and c lattice parameters. (orig.)

  1. An Electron microscopic, radioautographic study of protein synthesis in vitro in the palatal mucosa of the rat

    International Nuclear Information System (INIS)

    Kim, Hyun Joo

    1987-01-01

    The incorporation of 3H-proline by epithelial and connective tissue elements of rat palatal mucosa was studied in order to investigate the relative levels of protein synthesis by the epithelium and underlying connective tissue cells. Following a sixty minutes incorporation of the radioactive tracer in vitro, it was found that the suprabasal cells had most grains per unit area. Furthermore, the grains were more concentrated over the cytoplasm than the nucleus. This was in contrast with the labeling of basal cells which had twice as many grains over the nucleoplasm than that over the cytoplasm. In intermediate cells; i.e., the spinous layer, the number of silver grains per unit area was decreased from that of the surprabasal cells. In area where desmosomes were more prominent, many grains were in touch with such desmosomes. However, the labeling appeared to be reduced as soon as the cells became flattened. Moreover, the epidermal keratohyalin granules were relatively free of grains. Except for certain intercellular surfaces the keratinized cells were generally free of grains. On the connective tissue side, silver grains were primarily localized over the fibroblasts with occasional grains over collagenous fibers were found over palatal muscle cells, neural elements and so on. Most grains over collagenous fibers were found in relation to mature collagen fibrils. Thus, protein synthesis in isolated mucosas of the rat palate apparent take place both in epithelial and connective elements. There were no apparent tissue alterations caused by the in vitro incorporation procedure utilized under conditions of this study. Key words: Electron microscopy, Radioautography, Protein synthesis, In vitro, Rat, Palate, 3H-poline

  2. Development of superconducting cryo-electron microscope and its applications

    International Nuclear Information System (INIS)

    Iwatsuki, Masashi

    1988-01-01

    Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.) [de

  3. Simultaneous specimen and stage cleaning device for analytical electron microscope

    Science.gov (United States)

    Zaluzec, Nestor J.

    1996-01-01

    An improved method and apparatus are provided for cleaning both a specimen stage, a specimen and an interior of an analytical electron microscope (AEM). The apparatus for cleaning a specimen stage and specimen comprising a plasma chamber for containing a gas plasma and an air lock coupled to the plasma chamber for permitting passage of the specimen stage and specimen into the plasma chamber and maintaining an airtight chamber. The specimen stage and specimen are subjected to a reactive plasma gas that is either DC or RF excited. The apparatus can be mounted on the analytical electron microscope (AEM) for cleaning the interior of the microscope.

  4. Microscopic studies of RIB target materials and ion induced nanostructures

    International Nuclear Information System (INIS)

    Karmakar, Prasanta; Bhattacharya, Shampa; Roy, Tapatee Kundu; Bhowmick, Debasis; Chakrabarti, Alok

    2010-01-01

    The invention of electron microscope and scanning probe microscope has empowered us to visualize the tiny world that has explored many fundamental laws of natures. Further technological advancements have made these tools capable to probe micron size structures to individual atom. These microscopes are used to image and study micron size fibers or grain structures used for high yield radioactive products, to few nanometer size ripple, dot and hole structures produced by ion irradiation. Electron Microscope has also been used to characterize the ion beam synthesized dilute magnetic systems

  5. Fabrication and electric measurements of nanostructures inside transmission electron microscope.

    Science.gov (United States)

    Chen, Qing; Peng, Lian-Mao

    2011-06-01

    Using manipulation holders specially designed for transmission electron microscope (TEM), nanostructures can be characterized, measured, modified and even fabricated in-situ. In-situ TEM techniques not only enable real-time study of structure-property relationships of materials at atomic scale, but also provide the ability to control and manipulate materials and structures at nanoscale. This review highlights in-situ electric measurements and in-situ fabrication and structure modification using manipulation holder inside TEM. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Provenance study through analysis of microstructural characteristics using an optical microscope and scanning electron microscopy for Goryeo celadon excavated from the seabed.

    Science.gov (United States)

    Min-su, Han

    2013-08-01

    This paper aims at identifying the provenance of Goryeo celadons by understanding its microstructural characteristics, such as particles, blisters, forms and amount of pores, and the presence of crystal formation, bodies, and glazes and its boundary, using an optical microscope and scanning electron microscopy (SEM). The analysis of the reproduced samples shows that the glazed layer of the sherd fired at higher temperatures has lower viscosity and therefore it encourages the blisters to be combined together and the layer to become more transparent. In addition, the result showed that the vitrification and melting process of clay minerals such as feldspars and quartzs on the bodies was accelerated for those samples. To factor such characteristics of the microstructure and apply it to the sherds, the samples could be divided into six categories based on status, such as small particles with many small pores or mainly large and small circular pores in the bodies, only a limited number of varied sized blisters in the glazes, and a few blisters and needle-shaped crystals on the boundary surface. In conclusion, the analysis of the microstructural characteristics using an optical microscope and SEM have proven to be useful as a categorizing reference factor in a provenance study on Goryeo celadons.

  7. Energy dispersive X-ray analysis in the electron microscope

    CERN Document Server

    Bell, DC

    2003-01-01

    This book provides an in-depth description of x-ray microanalysis in the electron microscope. It is sufficiently detailed to ensure that novices will understand the nuances of high-quality EDX analysis. Includes information about hardware design as well as the physics of x-ray generation, absorption and detection, and most post-detection data processing. Details on electron optics and electron probe formation allow the novice to make sensible adjustments to the electron microscope in order to set up a system which optimises analysis. It also helps the reader determine which microanalytical me

  8. Integration of a high-NA light microscope in a scanning electron microscope.

    Science.gov (United States)

    Zonnevylle, A C; Van Tol, R F C; Liv, N; Narvaez, A C; Effting, A P J; Kruit, P; Hoogenboom, J P

    2013-10-01

    We present an integrated light-electron microscope in which an inverted high-NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high-resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub-10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum-compatible immersion oil. For a 40-nm-diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry. © 2013 The Authors Journal of Microscopy © 2013 Royal Microscopical Society.

  9. Light, electron microscopic and immunohistochemical study of the effect of low-dose aspirin during the proestrus phase on rat endometrium in the preimplantation period.

    Science.gov (United States)

    Ateş, Utku; Baka, Meral; Turgut, Mehmet; Uyanikgil, Yiğit; Ulker, Sibel; Yilmaz, Ozlem; Tavmergen, Erol; Yurtseven, Mine

    2007-04-01

    To evaluate structural alterations in rat endometrium at preimplantation following treatment with aspirin beginning from proestrus by light microscopy, electron microscopy and immunohistochemical techniques. Twenty rats were divided into control (n = 10) and experimental (n = 10) groups. Experimental rats were treated with low-dose aspirin daily (2 mg/kg/day) during estrus, beginning from the proestrus phase, mated at end of cycle and treated with aspirin. Untreated pregnant rats were the control group. Rats in both groups were sacrificed at the 84th pregnancy hour; the uterus was rapidly removed and dissected free of surrounding adipose tissue. Uteri specimens from nonpregnant rats were transferred into fixative solution and processed for light, electron microscopic and immunohistochemical study. Light and electron microscopy of endometrium from control rats conformed to mid-diestrus phase; endometrial histology of the aspirin-treated group conformed to late diestrus phase. The endometrial layer was significantly thicker in the aspirin-treated group compared to the untreated control group (p <0.001). No significant difference was found in vessel number between groups. Staining with alphaV integrin was more dense in the aspirin-treated group. Based on histologic findings, we suggest low-dose aspirin has positive effects on preparing endometrium before implantation.

  10. Electron microscopic study on the initial effect of gamma-irradiation on the chromatin structure of L cells

    International Nuclear Information System (INIS)

    Kondo, Takashi; Nakanishi, Y.H.; Yoshii, Giichi

    1979-01-01

    Mouse L cells are gamma-irradiated at a dose of 1 Mrad, and ultrathin sections of the cells are examined by electron microscopy. The distance between chromatin fibers in diffused chromatin regions in the irradiated nuclei is essentially identical with the nonirradiated control. In contrast, an increase of the distance between the chromatin fibers is observed in the excess of Ca ions in irradiation. (author)

  11. Role of l-carnitine in the prevention of seminiferous tubules damage induced by gamma radiation: a light and electron microscopic study

    Energy Technology Data Exchange (ETDEWEB)

    Topcu-Tarladacalisir, Yeter; Kanter, Mehmet [Trakya University, Department of Histology and Embryology, Faculty of Medicine, Edirne (Turkey); Uzal, Mustafa Cem [Trakya University, Department of Radiation Oncology, Faculty of Medicine, Edirne (Turkey)

    2009-08-15

    The present study, we hypothesized that l-carnitine can minimize germ-cell depletion and morphological features of late cell damage in the rat testis following gamma ({gamma})-irradiation. Wistar albino male rats were divided into three groups. Control group received physiological saline 0.2 ml intraperitoneally (i.p.), as placebo. Radiation group received scrotal {gamma}-irradiation of 10 Gy as a single dose plus physiological saline. Radiation + l-carnitine group received scrotal {gamma}-irradiation plus 200 mg/kg i.p. l-carnitine. l-carnitine starting 1 day before irradiation and 21 days (three times per week) after irradiation. Testis samples of the all groups were taken at day 21, 44 and 70 post-irradiation. All samples were processed at the light and electron microscopic levels. Morphologically, examination of {gamma}-irradiated testis revealed presence of marked disorganization and depletion of germ cells, arrest of spermatogenesis, formation of multinucleated giant cells, and vacuolization in the germinal epithelium. The type and extent of these changes varied at different post-treatment intervals. The damage was evident at the 21st day and reached maximum level by the 44th day. By day 44 post-irradiation, the changes were most advanced, and were associated with atrophied seminiferous tubules without germ cells, the increase in the number and size of vacuolizations in germinal epithelium, and the absent multinucleated giant cells due to spermatids had completely disappeared. The increase in nucleus invaginations, the dilatation of smooth endoplasmic reticulum cysternas and the increase in the number and size of lipid droplets in the Sertoli cells were determined at the electron microscopic level. In conclusion, l-carnitine supplementation during the radiotherapy would be effective in protecting against radiation-induced damages in rat testis, and thereby may improve the quality of patient's life after the therapy. (orig.)

  12. Role of l-carnitine in the prevention of seminiferous tubules damage induced by gamma radiation: a light and electron microscopic study

    International Nuclear Information System (INIS)

    Topcu-Tarladacalisir, Yeter; Kanter, Mehmet; Uzal, Mustafa Cem

    2009-01-01

    The present study, we hypothesized that l-carnitine can minimize germ-cell depletion and morphological features of late cell damage in the rat testis following gamma (γ)-irradiation. Wistar albino male rats were divided into three groups. Control group received physiological saline 0.2 ml intraperitoneally (i.p.), as placebo. Radiation group received scrotal γ-irradiation of 10 Gy as a single dose plus physiological saline. Radiation + l-carnitine group received scrotal γ-irradiation plus 200 mg/kg i.p. l-carnitine. l-carnitine starting 1 day before irradiation and 21 days (three times per week) after irradiation. Testis samples of the all groups were taken at day 21, 44 and 70 post-irradiation. All samples were processed at the light and electron microscopic levels. Morphologically, examination of γ-irradiated testis revealed presence of marked disorganization and depletion of germ cells, arrest of spermatogenesis, formation of multinucleated giant cells, and vacuolization in the germinal epithelium. The type and extent of these changes varied at different post-treatment intervals. The damage was evident at the 21st day and reached maximum level by the 44th day. By day 44 post-irradiation, the changes were most advanced, and were associated with atrophied seminiferous tubules without germ cells, the increase in the number and size of vacuolizations in germinal epithelium, and the absent multinucleated giant cells due to spermatids had completely disappeared. The increase in nucleus invaginations, the dilatation of smooth endoplasmic reticulum cysternas and the increase in the number and size of lipid droplets in the Sertoli cells were determined at the electron microscopic level. In conclusion, l-carnitine supplementation during the radiotherapy would be effective in protecting against radiation-induced damages in rat testis, and thereby may improve the quality of patient's life after the therapy. (orig.)

  13. Development of spin-polarized transmission electron microscope

    International Nuclear Information System (INIS)

    Kuwahara, M; Saitoh, K; Tanaka, N; Takeda, Y; Ujihara, T; Asano, H; Nakanishi, T

    2011-01-01

    In order to study spin related phenomena in nano-size materials, spin-polarized electron source (PES) has been employed for the incident beam in transmission electron microscope (TEM). The PES has been designed and constructed with optimizing for spin-polarized TEM. The illuminating system of TEM is also designed to focus the spin-polarized electron beam emitted from a semiconductor photocathode with a negative electron affinity (NEA) surface. The beam energy is set to below 40 keV which is lower energy type as a TEM, because the spin interaction with condensed matters is very small corresponding with a Coulomb interaction. The polarized electron gun has realized in an extra high vacuum (XHV) condition and high field gradient of 4 MV/m on a surface of photocathode. Furthermore, it demonstrated that 40-keV polarized electron beam was operated with a sub-milli second pulse mode by using the backside excitation type photocathode. This high performance PES will make it possible to observe dynamically a magnetic field images with high contrast and highspeed temporal imaging in TEM.

  14. Electron microscopic observations and DNA chain fragmentation studies on apoptosis in bone tumor cells induced by 153Sm-EDTMP

    International Nuclear Information System (INIS)

    Zhu Shoupeng; Xiao Dong; Han Xiaofeng

    1997-01-01

    The morphological changes observed by electron microscopy indicate that after internal irradiation with 153 Sm-EDTMP bone tumor cells displayed feature of apoptosis, such as margination of condensed chromatin, chromatin fragmentation, as well as the membrane bounded apoptotic bodies formation. The quantification analysis of fragmentation DNA for bone tumor cells induced by 153 Sm-EDTMP shows that the DNA fragmentation is enhanced with the prolongation of internally irradiated time. These characteristics suggest that 153 Sm-EDTMP internal irradiation could induce bone tumor cells to go to apoptosis

  15. Conservation of 19th and early 20th century oil paintings - in situ studies using the environmental scanning electron microscope

    International Nuclear Information System (INIS)

    White, R.; Phillips, M.; Wuhrer, R.; Thomas, D.

    2003-01-01

    Full text: Most 19th and early 20th century oil paintings suffer from fading, discolouration, pitting, cracking swelling or the loss of material due to the embrittlement or the extreme friability of the paint layers. As a consequence of this deterioration, they require special care by experienced conservators to ensure their continued preservation. These aging processes are a consequence of (i) chemical interactions between pigments, oils and binders used by the artist and (ii) the action of air, water and ultra-violet irradiation on these materials. The influence of chemical interactions is pertinent for paintings of this era as the industrial revolution brought forth new colourful chemicals that were quickly adopted as pigments with varying success. The conservation of oil paintings requires an understanding of the individual structure of each work of art and what mechanisms underlie its deterioration. This generally involves the need for (i) correct identification of the pigments used by the artist, (ii) a detailed knowledge of the chemical interaction between these pigments, (iii) an understanding of the artist's method of mixing colours and laying paint on the canvas and (iv) a detailed knowledge of the role of the atmosphere, moisture and UV irradiation on painting deterioration. In addition to dealing with the deterioration that occurs within the painting, conservators spend a large portion of their time correcting earlier failed conservation attempts. Most oil paintings from this era are valuable from an artistic or historic perspective and only an extremely small sample may be excised from the work, hence microscopy is an indispensable technique in art preservation. Optical microscopy is the core analysis technique used, however, in recent years a limited number of conservators have begun to use Environmental scanning electron microscopy (ESEM) technology to examine paint layers to take advantage of the accurate and rapid identification of elements present

  16. An Electron Microscope Study of the Thermal Neutron Induced Loss in High Temperature Tensile Ductility of Nb Stabilized Austenitic Steels

    Energy Technology Data Exchange (ETDEWEB)

    Roy, R B

    1965-04-15

    Irradiated {approx}3 x 10{sup 19} n/cm{sup 2} (thermal), <3 x 10{sup 18} n/cm{sup 2} (> 1 MeV) at 40 deg C and the corresponding unirradiated control tensile specimens of a 20 % Cr, 25 % Ni, Nb stabilized steel tested at 650 deg C, 750 deg C and 800 deg C have been examined by transmission electron microscopy. The results indicate that the irradiation induced embrittlement of the tensile specimens at elevated temperatures is preceded by the formation of fine precipitates within the grains. These precipitates may restrict the deformation within the grains such that the stresses are concentrated at the grain boundaries thereby leading to premature failure. It is suggested that the main effect of the irradiation is to promote conditions necessary for the formation of these precipitates, namely, super saturation and fresh nucleation sites within the matrix through the energetic emission of He and Li atoms from boron as an impurity.

  17. An Electron Microscope Study of the Thermal Neutron Induced Loss in High Temperature Tensile Ductility of Nb Stabilized Austenitic Steels

    International Nuclear Information System (INIS)

    Roy, R.B.

    1965-04-01

    Irradiated ∼3 x 10 19 n/cm 2 (thermal), 18 n/cm 2 (> 1 MeV) at 40 deg C and the corresponding unirradiated control tensile specimens of a 20 % Cr, 25 % Ni, Nb stabilized steel tested at 650 deg C, 750 deg C and 800 deg C have been examined by transmission electron microscopy. The results indicate that the irradiation induced embrittlement of the tensile specimens at elevated temperatures is preceded by the formation of fine precipitates within the grains. These precipitates may restrict the deformation within the grains such that the stresses are concentrated at the grain boundaries thereby leading to premature failure. It is suggested that the main effect of the irradiation is to promote conditions necessary for the formation of these precipitates, namely, super saturation and fresh nucleation sites within the matrix through the energetic emission of He and Li atoms from boron as an impurity

  18. Lungs of the gecko Rhacodactylus leachianus (Reptilia: Gekkonidae): a correlative gross anatomical and light and electron microscopic study.

    Science.gov (United States)

    Perry, S F; Bauer, A M; Russell, A P; Alston, J T; Maloney, J E

    1989-01-01

    The lungs of the New Caldeonian gecko Rhacodactylus leachianus were examined by means of gross dissection and light and electron microscopy. This tropical species, which is the largest living gecko, possesses two simple, single-chambered lungs. Right and left lungs are of similar size and shape. The lung volume (27.2 ml.100 g-1) is similar to that of the tokay (Gekko gecko) but differs in that the gas exchange tissue is approximately homogeneously distributed, and the parenchymal units (ediculae) are very large, approximately 2 mm in diameter. The parenchymal depth varies according to the location in the lung, being deepest near the middle of the lung and shallowest caudally. Scanning and transmission electron microscopy reveal an unusual distribution of ciliated cells in patches on the edicular walls as well as on the trabeculae. Secretory cells are very numerous, particularly in the bronchial epithelium, where they greatly outnumber the ciliated cells. The secretory cells form a morphological continuum characterized by small secretory droplets apically and large vacuoles basally. This continuum includes cells resembling type II pneumocytes but which are devoid of lamellar bodies. Type I pneumocytes similar to those of other reptiles cover the respiratory capillaries, where they form a thin, air-blood barrier together with the capillary endothelial cells and the fused basement laminae. The innervation, musculature, and vascular distribution in R. leachianus are also characterized. Apparent simplification of the lungs in this taxon may be related to features of its sluggish habits, whereas peculiarities of cell and tissue composition may reflect demands of its mesic habitat.

  19. Scanning electron microscope autoradiography of critical point dried biological samples

    International Nuclear Information System (INIS)

    Weiss, R.L.

    1980-01-01

    A technique has been developed for the localization of isotopes in the scanning electron microscope. Autoradiographic studies have been performed using a model system and a unicellular biflagellate alga. One requirement of this technique is that all manipulations be carried out on samples that are maintained in a liquid state. Observations of a source of radiation ( 125 I-ferritin) show that the nuclear emulsion used to detect radiation is active under these conditions. Efficiency measurement performed using 125 I-ferritin indicate that 125 I-SEM autoradiography is an efficient process that exhibits a 'dose dependent' response. Two types of labeling methods were used with cells, surface labeling with 125 I and internal labeling with 3 H. Silver grains appeared on labeled cells after autoradiography, removal of residual gelatin and critical point drying. The location of grains was examined on a flagellated green alga (Chlamydomonas reinhardi) capable of undergoing cell fusion. Fusion experiments using labeled and unlabeled cells indicate that 1. Labeling is specific for incorporated radioactivity; 2. Cell surface structure is preserved in SEM autoradiographs and 3. The technique appears to produce reliable autoradiographs. Thus scanning electron microscope autoradiography should provide a new and useful experimental approach

  20. Interaction of electrons with light metal hydrides in the transmission electron microscope.

    Science.gov (United States)

    Wang, Yongming; Wakasugi, Takenobu; Isobe, Shigehito; Hashimoto, Naoyuki; Ohnuki, Somei

    2014-12-01

    Transmission electron microscope (TEM) observation of light metal hydrides is complicated by the instability of these materials under electron irradiation. In this study, the electron kinetic energy dependences of the interactions of incident electrons with lithium, sodium and magnesium hydrides, as well as the constituting element effect on the interactions, were theoretically discussed, and electron irradiation damage to these hydrides was examined using in situ TEM. The results indicate that high incident electron kinetic energy helps alleviate the irradiation damage resulting from inelastic or elastic scattering of the incident electrons in the TEM. Therefore, observations and characterizations of these materials would benefit from increased, instead decreased, TEM operating voltage. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Isotope, scanning electron microscope, and energy dispersive spectrometer studies of heterogeneous zircons from radioactive granites in the Grenville structural province, Quebec and Ontario

    International Nuclear Information System (INIS)

    Rimsaite, J.

    1981-01-01

    Heterogeneous zircons yielded discordant Pb-U, Pb-Th, and 207 Pb- 206 Pb isotopic ages. Most data points fall below the concordia curve, implying losses of daughter elements, bqt they define a discordia line that intersects the concordia at approximately 90 Ma and 1020 Ma. To obtain evidence for mobilization of U and radiogenic Pb, zircon grains were studied using a scanning electron microscope coupled with an energy dispersive spectrometer. High magnification backscattered and secondary electron images of the zircon revealed narrow fractures, zoning and diverse mineral inclusions. Three groups of mineral inclusions observed were: 1) those predating zoned zircon and apparently serving as a nucleus; 2) uraninite, feldspar, and apatite associated with the growth and zoning of the host zircon; and 3) fracture-fillings that postdate crystallization of the host zircon. The U- and Pb-rich inclusions incorporated into the zircon grains during and after its crystallization markedly affect isotopic ages of the host zircon. Migration of Pb and U have occurred along fractures in zircon. Zircon, uraninite, and other associated minerals have decomposed and complex reactions have taken place between the liberated Zr, U, Th and other elements to produce overgrowths on mineral grains and unidentified Zr-bearing material in fractures

  2. Effect of different aspirin doses on arterial thrombosis after canine carotid endarterectomy: a scanning electron microscope and indium-111-labeled platelet study

    International Nuclear Information System (INIS)

    Ercius, M.S.; Chandler, W.F.; Ford, J.W.; Swanson, D.P.; Burke, J.C.

    1984-01-01

    Although it is widely accepted that aspirin inhibits platelet aggregation in arterial thrombosis, the appropriate dosage of aspirin remains quite controversial. The purpose of this study was to determine the effect of different doses of aspirin (0.5 mg/kg vs. 10 mg/kg) on mural thrombus formation after carotid endarterectomy. Eighteen hours after oral aspirin administration, 20 endarterectomies were performed on mongrel dogs with the use of the operating microscope. Blood flow was then restored for 3 hours and the vessels were prepared for investigation with the scanning electron microscope. Ten endarterectomies were also performed on unmedicated dogs as controls. Five minutes before vessel unclamping, autologous indium-111-labeled platelets were administered intravenously, and the endarterectomized portions of the vessels were studied with a gamma counter system after harvesting. Group 1, the control group, revealed extensive mural thrombus consisting of platelet aggregates, fibrin, red blood cells, and white blood cells. Six of the 10 vessels in Group 2, premedicated with 0.5 mg of aspirin per kg, demonstrated varying amounts of mural thrombus. Group 3 (10 vessels), premedicated with 10 mg of aspirin per kg, revealed a platelet monolayer completely covering the exposed vessel wall media, with scattered white blood cells and infrequent fine fibrin strands overlying the platelet surface. The mean (+/- SD) radioactivity per group expressed as counts/minute/mm2 was: Group 1--2055.3 +/- 1905.5, log . 7.253 +/- 0.926; Group 2--1235.6 +/- 1234.3, log . 6.785 +/- 0.817; Group 3--526 +/- 433.06, log . 5.989 +/- 0.774

  3. Shielded scanning electron microscope for radioactive samples

    International Nuclear Information System (INIS)

    Crouse, R.S.; Parsley, W.B.

    1977-01-01

    A small commercial SEM had been successfully shielded for examining radioactive materials transferred directly from a remote handling facility. Relatively minor mechanical modifications were required to achieve excellent operation. Two inches of steel provide adequate shielding for most samples encountered. However, samples reading 75 rad/hr γ have been examined by adding extra shielding in the form of tungsten sample holders and external lead shadow shields. Some degradation of secondary electron imaging was seen but was adequately compensated for by changing operating conditions

  4. Electron-microscopic autoradiography of tritiated testosterone in rat testis

    International Nuclear Information System (INIS)

    Frederik, P.M.; Molen, H.J. van der; Galjaard, H.; Klepper, D.

    1977-01-01

    The feasibility of a technique for autoradiography of diffusible substances has been further tested by analysing the localization of steroids in rats testes with the light- and electron-microscope. Testes of rats were perfused with tritiated testosterone (3 min) followed by 15-min perfusion with buffer containing a 100-fold excess of unlabelled testosterone. Tissue samples were frozen, freeze dried, fixed in osmium vapour and embedded in Epon. To exclude extraction of steroids, contact with water and other solvents was prevented during cutting of thin sections on an ultracryotome and further treatment for autoradiography. Light- and electron-microscopic observations indicated that the highest concentration of labelled testosterone was present within the basal parts of the Sertoli cell cytoplasm and in lipid inclusions of Sertoli cells within the seminiferous tubules. This is the first account of autoradiography of steroids at the electron-microscope level. (author)

  5. Comparative study on the dependence of quantitative results in the electron microscopic autoradiography on the type of developer (Microdol X, Phenidon)

    International Nuclear Information System (INIS)

    David, H.; Marx, I.; Nanoff, S.

    1978-01-01

    It was the aim of the investigation to compare quantitative results of electron microscopic autoradiographs after the use of different developers (Microdol X, Phenidon) adapting morphometrical methods. Erythroblasts of rabbit were tested after incorporation of 3 H-uridine in vitro. Both developers showed the same tendency at higher rates of incorporation (basophilic erythroblasts and polychromatic erythroblasts). Using Phenidon, however, we could obtain only half the values for the individual cell components. At high rates of incorporation Microdol X results in an overlapping of the silver filaments. Thus, more distinct grains can be reached by Phenidon. At smaller rates of incorporation (orthochromatic erythroblasts) after using. Phenidon a quantitative evaluation is however influenced by too many factors of uncertainty so that according to our investigations Microdol X is better suited for a quantitative evaluation of electron microscopic autoradiographs. (author)

  6. Quantitative electron microscopical autoradiography of calcium during amelogenesis

    International Nuclear Information System (INIS)

    Nagai, Yoshinori; Frank, R.M.

    1975-01-01

    The migration of 45 Ca through the stratum intermedium and through the secreting ameloblasts towards enamel has been studied by electron microscopical autoradiography in the toothgerms of newborn cats. A quantitative procedure was applied to the study of the 45 Ca migration in amelogenesis and two pathways were demonstrated. The relatively more important direct route passed through the stratum intermedium and the ameloblast intercellular spaces and reached the enamel directly. The second pathway consisted of an intracellular migration through the ameloblast. 45 Ca penetrated the cell through its basal pole. The mitochondrias were the most highly labeled organelles at the different experimental time intervals studied. A total absence of silver grains was noted over the secretory ameloblastic bodies. At 6 hours, the highest labeling was observed over enamel. (auth.)

  7. Electron sputtering in the analytical electron microscope: Calculations and experimental data

    International Nuclear Information System (INIS)

    Zaluzec, N.J.; Mansfield, J.F.

    1987-03-01

    The environment of the electron microscope is particularly severe when one considers the energy deposited in a specimen during typical experimental conditions. Conventional imaging experiments tend to employ electron current densities ranging from ∼0.1 to 1 A/cm 2 while during microanalysis conditions probe current densities can range from 10 to values as high as 10 5 A/cm 2 . At 100 kV this corresponds to power densities from 100 Kilowatts/cm 2 to 10 4 Megawatts/cm 2 . These energy deposition rates can result in electron irradiation damage which can substantially alter the structure and composition of a specimen through either ionization damage in organics or by displacement damage in inorganics and/or combinations thereof. For the most part materials scientists operating an analytical electron microscope (AEM) in the 100 to 200 kV regime studying metallic and/or ceramic specimens have been spared the need to consider either of these effects as their specimens have tended to be sufficiently resilient. However, the advent of the new medium voltage microscopes operating in the 300 to 400 kV regime with high brightness guns and clean or ultrahigh vacuum systems has necessitated a reevaluation of the effects of higher voltage operation in light of the destructive nature of the electron beam particularly under microanalysis conditions

  8. Toxicological effects and recovery of the corneal epithelium in Cyprinus carpio communis Linn. exposed to monocrotophos: an scanning electron microscope study.

    Science.gov (United States)

    Uppal, Ravneet Kaur; Johal, Mohinder Singh; Sharma, Madan Lal

    2015-05-01

    This study was conducted based on the evidence of fish habitats in North India being affected by organophosphate pesticides draining from agricultural fields into bodies of water, especially during the rainy season. Various tissues of fish such as scales, gills ovaries, kidney, and liver have been studied from the toxicological point of view, but the toxicological effects of aquatic pollutants on fish cornea have not been investigated to date. We conducted comparative toxicological studies on the cornea of Cyprinus carpio communis using two sublethal (0.038 and 0.126 ppm) concentrations of monocrotophos pesticide for 30 days. Corneas from all the groups were evaluated by a scanning electron microscope. The fish exposed to the monocrotophos pesticide developed corneal necrosis due to the formation of crystalloid-like structures, thinning and shrinkage of microridges on the corneal epithelium. After 30 days, fish from the monocrotophos-treated tank were transferred to normal environmental conditions. After 60 days under natural condition, epithelial cells did not fully recover. In conclusion, exposure to monocrotophos induces irreversible changes in the cornea of C. carpio communis. As fish and mammalian visual systems share many similarities, the reported finding may offer useful insights for further toxicological and ophthalmological studies in humans. © 2013 American College of Veterinary Ophthalmologists.

  9. Scanning electron microscopic studies of gill arches and rakers in relation to feeding habits of some fresh water fishes

    Directory of Open Access Journals (Sweden)

    E.H. Elsheikh

    2013-05-01

    Prominent epithelial protuberances on the gill rakers and gill arches enable the taste buds, located at their summit, to project well above the surface of the epithelium. This could increase the efficiency of the taste buds in selective sorting of palatable food. Co-occurrence of teeth and taste buds on the epi-and hypopharyngeal bones (Types I–III denotes that food processing and gestation occur simultaneously in the pharynx. Caniform, villiform and papilliform teeth on the epi- and hypopharyngeal bones of the three studied species respectively in O. niloticus, C. auratus and C. gariepinus were associated with a complex food-processing cycle. Mucous secretions, oozing through mucous cell openings, provide lubrication facilitating smooth passage of food through the pharynx.

  10. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study

    Directory of Open Access Journals (Sweden)

    Vandana Kararia

    2015-01-01

    Full Text Available Introduction: The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM study of surface changes and complexometric titration to study compositional change was performed. Materials and Methods: Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" FNx010.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at Χ2000, Χ4000 and Χ6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. Observations and Results: The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0. Conclusion: Extensive and stringent trials are required before certifying any product to be used in Orthodontics.

  11. Premartensitic microstructures as seen in the high-resolution electron microscope: A study of a Ni-Al alloy

    International Nuclear Information System (INIS)

    Schryvers, D.; Tanner, L.; Van Tendeloo, G.

    1988-01-01

    The present study indicates that the B2 β-phase in quenched Ni/sub 62.5/Al/sub 37.5/ is distorted by displacement waves involving a planar shuffling of atoms resembling the final 7R martensite structure and with wavelenghts of the order of 1.3 nm. The appearance of a type modulation with the indicated periodicity corresponds well with recent inelastic neutron scattering results which reveal nonlinear behavior in the TA phonon dispersion curve around the same wavelengths indicating a partial lattice softening for such waves. In bulk material all six equivalent wave-vectors are equally present. These distortional modulations are configured in some form of three-dimensional assembly. Following the interpretation given above, it can be concluded that a one-dimensional domain structure along one of six directions may exist. However, the beating of six displacement waves with apparently uncorrelated phase and wavelengths rules out the existence of a ''conventional'' three-dimensional domain structure. For this reason it is uncertain whether much more information can be gained from such image simulations. There are now numerous indications that the underlying structure to the tweed contrast in this alloy is a precursor effect of the martensitic transformation. However, a detailed description of the effective correlation between the distorted parent phase and the martensitic product phase has yet to be developed. Recent HREM results reveal the existence of a sequence of different structures in the transition region between the modulated β-phase and the martensitic phase, depending on parameters such as the local composition and stress. Such transition structures include modulated β-phase in which only one [110] modulation is preferred or in which the periodicity differs from the above described 1.3 nm and the FCT L1/sub o/ martensite with single shear defects. 26 refs., 1 fig

  12. In situ ion etching in a scanning electron microscope

    International Nuclear Information System (INIS)

    Dhariwal, R.S.; Fitch, R.K.

    1977-01-01

    A facility for ion etching in a scanning electron microscope is described which incorporates a new type of electrostatic ion source and viewing of the specimen is possible within about 30 sec after terminating the ion bombardment. Artefacts produced during etching have been studied and cone formation has been followed during its growth. The instrument has provided useful structural information on metals, alloys, and sinters. However, although insulating materials, such as plastics, glass and resins, have been successfully etched, interpretation of the resultant micrographs is more difficult. Ion etching of soft biological tissues, such as the rat duodenum was found to be of considerable interest. The observed structural features arise from the selective intake of the heavy fixation elements by different parts of the tissue. Hard biological materials, such as dental tissues and restorative materials, have also been studied and the prismatic structure of the enamel and the form and distribution of the dentinal tubules have been revealed. (author)

  13. Quantitative electron microscopical autoradiography of calcium during dentinogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Nagai, Y [Tokyo Dental Coll. (Japan); Frank, R M

    1975-03-01

    /sup 45/Ca migration from the dental papilla and the odontablasts towards predentin and dentin has been studied through electron microscopical autoradiography in toothgerms of newborn cats. A quantitative procedure was applied to the study of the /sup 45/Ca migration in dentinogenesis. Two pathways of almost identical importance have been demonstrated. The direct pathway followed the intercellular spaces of the dental papilla and of the odontoblasts and reached the dentin via predentin. The second road, after passage through the intercellular spaces of the dental papilla, consisted of an intracellular migration through the odontoblast. The mitochondria and the golgi apparatus were progressively the most labelet at 5 min., 30 min. and 1 h. after intravenous injection. The calcium diffused into the odontablastic process without being associated with the dense granule. At 6 hours, maximum radioactivity was observed in the intertubular dentin.

  14. Scanning tunnel microscope with large vision field compatible with a scanning electron microscope

    International Nuclear Information System (INIS)

    Volodin, A.P.; Stepanyan, G.A.; Khajkin, M.S.; Ehdel'man, V.S.

    1989-01-01

    A scanning tunnel microscope (STM) with the 20μm vision field and 1nm resolution, designed to be compatible with a scanning electron microscope (SEM), is described. The sample scanning area is chosen within the 3x10mm limits with a 0.1-1μm step. The STM needle is moved automatically toward the sample surface from the maximum distance of 10mm until the tunneling current appears. Bimorphous elements of the KP-1 piezocorrector are used in the STM design. The device is installed on a table of SEM object holders

  15. Electron beam dynamics in an ultrafast transmission electron microscope with Wehnelt electrode.

    Science.gov (United States)

    Bücker, K; Picher, M; Crégut, O; LaGrange, T; Reed, B W; Park, S T; Masiel, D J; Banhart, F

    2016-12-01

    High temporal resolution transmission electron microscopy techniques have shown significant progress in recent years. Using photoelectron pulses induced by ultrashort laser pulses on the cathode, these methods can probe ultrafast materials processes and have revealed numerous dynamic phenomena at the nanoscale. Most recently, the technique has been implemented in standard thermionic electron microscopes that provide a flexible platform for studying material's dynamics over a wide range of spatial and temporal scales. In this study, the electron pulses in such an ultrafast transmission electron microscope are characterized in detail. The microscope is based on a thermionic gun with a Wehnelt electrode and is operated in a stroboscopic photoelectron mode. It is shown that the Wehnelt bias has a decisive influence on the temporal and energy spread of the picosecond electron pulses. Depending on the shape of the cathode and the cathode-Wehnelt distance, different emission patterns with different pulse parameters are obtained. The energy spread of the pulses is determined by space charge and Boersch effects, given by the number of electrons in a pulse. However, filtering effects due to the chromatic aberrations of the Wehnelt electrode allow the extraction of pulses with narrow energy spreads. The temporal spread is governed by electron trajectories of different length and in different electrostatic potentials. High temporal resolution is obtained by excluding shank emission from the cathode and aberration-induced halos in the emission pattern. By varying the cathode-Wehnelt gap, the Wehnelt bias, and the number of photoelectrons in a pulse, tradeoffs between energy and temporal resolution as well as beam intensity can be made as needed for experiments. Based on the characterization of the electron pulses, the optimal conditions for the operation of ultrafast TEMs with thermionic gun assembly are elaborated. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A Scanning Electron Microscopic Study

    African Journals Online (AJOL)

    2018-06-11

    Jun 11, 2018 ... 2018 Nigerian Journal of Clinical Practice | Published by Wolters Kluwer ‑ Medknow ... evaluate and compare the effect of different concentrations of carbamide .... Cements such as resin, glass ionomer, resin‑modified.

  17. Effect of residual chips on the material removal process of the bulk metallic glass studied by in situ scratch testing inside the scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Hu Huang

    2012-12-01

    Full Text Available Research on material removal mechanism is meaningful for precision and ultra-precision manufacturing. In this paper, a novel scratch device was proposed by integrating the parasitic motion principle linear actuator. The device has a compact structure and it can be installed on the stage of the scanning electron microscope (SEM to carry out in situ scratch testing. Effect of residual chips on the material removal process of the bulk metallic glass (BMG was studied by in situ scratch testing inside the SEM. The whole removal process of the BMG during the scratch was captured in real time. Formation and growth of lamellar chips on the rake face of the Cube-Corner indenter were observed dynamically. Experimental results indicate that when lots of chips are accumulated on the rake face of the indenter and obstruct forward flow of materials, materials will flow laterally and downward to find new location and direction for formation of new chips. Due to similar material removal processes, in situ scratch testing is potential to be a powerful research tool for studying material removal mechanism of single point diamond turning, single grit grinding, mechanical polishing and grating fabrication.

  18. Synthesis, Spectral Characterization, Electron Microscopic Study and Influence on the Thermal Stability of Phosphorus-containing Dendrimer with a 4,4'-Sulphonyldiphenol at the Core

    Energy Technology Data Exchange (ETDEWEB)

    Dadapeer, Echchukattula; Rasheed, Syed; Raju, Chamarthi Naga [Sri Venkateswara University, Tirupat (India)

    2011-02-15

    The divergent synthesis of novel phosphorus-containing dendrimer with 4,4'-sulphonyldiphenol at the core has been accomplished involving simple condensation reactions using P(O)Cl{sub 3}, P(S)Cl{sub 3}, 3-amino-phenol, 3-hydroxy-benzaldehyde, and 2-butyn 1, 4-diol. The final compound was a Schiff's base macromolecule possessing 4 imine bonds, 8 acetylenic bonds and 8 OH groups at the periphery. The structures of intermediate compounds were confirmed by IR, NMR ({sup 1}H, {sup 13}C and {sup 31}P), LC-Mass and C, H, N analysis. The structure of the final dendrimer was confirmed by IR, NMR ({sup 1}H, {sup 13}C and {sup 31}P), MALDI-TOF-MS, and C, H, N analysis. The surface morphological characteristics of the final dendrimer were understood by Scanning Electronic Microscopic study (SEM). The thermal stability of the final dendrimer was studied by TGA/DTA analysis.

  19. Mucopolysaccharides in the trabecular meshwork. Light and electron microscopic autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Yoshitaka; Yamana, Yasuo; Abe, Masahiro (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1982-09-01

    The localization of /sup 35/S-sulfate and /sup 3/H-glucosamine in the trabecular region of the hamster was studied by light and electron microscopic autoradiography after the intraperitoneal injection. Exposed silver grains of /sup 35/S-sulfate were concentrated in the trabecular meshwork, sclera and cornea, and grains of /sup 35/H-glucosamine were localized in the trabecular region. The radioactivity of both isotopes was observed in the Golgi apparatuses of the endothelial cells and fibroblasts in Schlemm's canal and the trabecular meshwork. Thereafter, the grains were noted over the entire cytoplasm, except for the nucleus, and then were incorporated into the amorphous substance and collagen fibers in the juxtacanalicular connective tissue. These results suggest that endothelial cells in the trabecular region synthesize and secrete the sulfated mucopolysaccharides and hyaluronic acid.

  20. Characterization of polycapillary optics installed in an analytical electron microscope

    International Nuclear Information System (INIS)

    Takano, Akira; Maehata, Keisuke; Iyomoto, Naoko; Hara, Toru; Mitsuda, Kazuhisa; Yamasaki, Noriko; Tanaka, Keiichi

    2016-01-01

    An energy-dispersive spectrometer with a superconducting transition edge sensor (TES) microcalorimeter mounted on a scanning transmission electron microscope (STEM) is developed to enhance the accuracy of nanoscale materials analysis. TES microcalorimeters generally have sensitive surface areas of the order of 100 × 100 µm 2 . Also, the magnetic field generated by the STEM objective lens means that a TES microcalorimeter cannot be placed in a STEM column. We therefore use polycapillary optics to collect the X-rays. In this study, X-rays are collected from a STEM specimen and are then focused on a silicon drift detector; from these measurements, the optics are characterized and the experimental results are compared with the design of the optics. (author)

  1. Fabrication and electric measurements of nanostructures inside transmission electron microscope

    International Nuclear Information System (INIS)

    Chen, Qing; Peng, Lian-Mao

    2011-01-01

    Using manipulation holders specially designed for transmission electron microscope (TEM), nanostructures can be characterized, measured, modified and even fabricated in-situ. In-situ TEM techniques not only enable real-time study of structure-property relationships of materials at atomic scale, but also provide the ability to control and manipulate materials and structures at nanoscale. This review highlights in-situ electric measurements and in-situ fabrication and structure modification using manipulation holder inside TEM. -- Research highlights: → We review in-situ works using manipulation holder in TEM. → In-situ electric measurements, fabrication and structure modification are focused. → We discuss important issues that should be considered for reliable results. → In-situ TEM is becoming a very powerful tool for many research fields.

  2. Electron microscopic observation at low temperature on superconductors

    International Nuclear Information System (INIS)

    Yokota, Yasuhiro; Hashimoto, Hatsujiro; Yoshida, Hiroyuki.

    1991-01-01

    The authors have observed superconducting materials with a high resolution electron microscope at liquid helium temperature. First, observation was carried out on Nb system intermetallic compounds such as Nb 3 Al and Nb 3 Sn of Al 5 type and Nb 3 Ge of 11 type at extremely low temperature. Next, the observation of high temperature superconductive ceramics in the state of superconductivity was attempted. In this paper, first the development of the liquid helium sample holder for a 400 kV electron microscope to realize the observation is reported. Besides, the sample holder of Gatan Co. and an extremely low temperature, high resolution electron microscope with a superconducting lens are described. The purpose of carrying out the electron microscope observation of superconductors at low temperature is the direct observation of the crystalline lattice image in the state of superconductivity. Also the structural transformation from tetragonal crystals to rhombic crystals in Al 5 type superconductors can be observed. The results of observation are reported. (K.I.)

  3. Structure Identification in High-Resolution Transmission Electron Microscopic Images

    DEFF Research Database (Denmark)

    Vestergaard, Jacob Schack; Kling, Jens; Dahl, Anders Bjorholm

    2014-01-01

    A connection between microscopic structure and macroscopic properties is expected for almost all material systems. High-resolution transmission electron microscopy is a technique offering insight into the atomic structure, but the analysis of large image series can be time consuming. The present ...

  4. New Scanning Electron Microscope Used for Cryogenic Tensile Testing

    CERN Multimedia

    Maximilien Brice

    2013-01-01

    At CERN engineering department's installation for cryogenic tensile testing, the new scanning electron microscope (SEM) allows for detailed optical observations to be carried out. Using the SEM, surface coatings and tensile properties of materials can investigated in order to better understand how they behave under different conditions.

  5. On the resolution of the electron microscopic radioautography

    International Nuclear Information System (INIS)

    Uchida, Kazuko; Daimon, Tateo; Kawai, Kazuhiro

    1981-01-01

    The aim of electron microscopic radioautography is to reveal the exact localization of certain substances at the macromolecular level. In order to attain this object the establishment of a fine grain development method is indispensable. Some of latent images are formed at the contact surface between the polyhedral halide silver grain and the section surface, where the impact of #betta# particles come directly from the section involved, and since it is in contact with the section it remains in place even after development and gelatin removal. This latent image finally becomes a developed silver grain in the electron microscope radioautogram. Although the limit of resolution in electron microscopic radioautography is supposed to be the diameter of halide silver grains in emulsion, it may be improved by considering the fact that the contact area between the halide silver grain and the section surface is the minimum unit of resolution. The minimum resolution of electron microscopic radioautography was determined histologically to be about 100A. (author)

  6. Improved coating and fixation methods for scanning electron microscope autoradiography

    International Nuclear Information System (INIS)

    Weiss, R.L.

    1984-01-01

    A simple apparatus for emulsion coating is described. The apparatus is inexpensive and easily assembled in a standard glass shop. Emulsion coating for scanning electron microscope autoradiography with this apparatus consistently yields uniform layers. When used in conjunction with newly described fixation methods, this new approach produces reliable autoradiographs of undamaged specimens

  7. Scanning electron microscope facility for examination of radioactive materials

    International Nuclear Information System (INIS)

    Gibson, J.R.; Braski, D.N.

    1985-02-01

    An AMRAY model 1200B scanning electron microscope was modified to permit remote examination of radioactive specimens. Features of the modification include pneumatic vibration isolation of the column, motorized stage controls, improvements for monitoring vacuum, and a system for changing filaments without entering the hot cell

  8. Understanding the formation and growth of Ag nanoparticles on silver chromate induced by electron irradiation in electron microscope: A combined experimental and theoretical study

    International Nuclear Information System (INIS)

    Fabbro, Maria T.; Gracia, Lourdes; Silva, Gabriela S.; Santos, Luís P.S.; Andrés, Juan; Cordoncillo, Eloisa; Longo, E.

    2016-01-01

    Ag 2 CrO 4 microcrystals were synthesized using the co-precipitation method. These microcrystals were characterized through X-ray diffraction (XRD) with Rietveld analysis, field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) with energy-dispersive spectroscopy (EDS), micro-Raman (MR). XRD patterns and Rietveld refinement data showed that the material exhibits an orthorhombic structure without any deleterious phases. FE-SEM and TEM micrographs revealed the morphology and the growth of Ag nanoparticles on Ag 2 CrO 4 microcrystals during electron beam irradiation. These events were directly monitored in real-time. Their optical properties were investigated using ultraviolet-visible (UV–vis) diffuse reflectance spectroscopy that allowed the calculation of the optical band gap energy. Theoretical analyses based on the density functional theory level indicate that the incorporation of electrons is responsible for structural modifications and formation of defects on the [AgO 6 ] and [AgO 4 ] clusters, generating ideal conditions for the growth of Ag nanoparticles. - Graphical abstract: Theoretical representation of the Ag 2 CrO 4 orthorhombic structure. Display Omitted - Highlights: • The Ag 2 CrO 4 microcrystals indicate an orthorhombic structure. • The formation of Ag 0 promotes Ag-nanoparticle growth on the surface of the Ag 2 CrO 4 . • Electron irradiation of the material induces the formation of Ag vacancies.

  9. Response function and optimum configuration of semiconductor backscattered-electron detectors for scanning electron microscopes

    International Nuclear Information System (INIS)

    Rau, E. I.; Orlikovskiy, N. A.; Ivanova, E. S.

    2012-01-01

    A new highly efficient design for semiconductor detectors of intermediate-energy electrons (1–50 keV) for application in scanning electron microscopes is proposed. Calculations of the response function of advanced detectors and control experiments show that the efficiency of the developed devices increases on average twofold, which is a significant positive factor in the operation of modern electron microscopes in the mode of low currents and at low primary electron energies.

  10. Transmission environmental scanning electron microscope with scintillation gaseous detection device

    International Nuclear Information System (INIS)

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-01-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. - Highlights: • Novel scanning transmission electron microscopy (STEM) with an environmental scanning electron microscope (ESEM) called TESEM. • Use of the gaseous detection device (GDD) in scintillation mode that allows high resolution bright and dark field imaging in the TESEM. • Novel approach towards a unification of both vacuum and environmental conditions in both bulk/surface and transmission mode of electron microscopy

  11. Cathodoluminescence of semiconductors in the scanning electron microscope

    International Nuclear Information System (INIS)

    Noriegas, Javier Piqueras de

    2008-01-01

    Full text: Cathodoluminescence (CL) in the scanning electron microscope (SEM) is a nondestructive technique, useful for characterization of optical and electronic properties of semiconductors, with spatial resolution. The contrast in the images of CL is related to the presence of crystalline defects, precipitates or impurities and provides information on their spatial distribution. CL spectra allows to study local energy position of localized electronic states. The application of the CL is extended to semiconductor very different characteristics, such as bulk material, heterostructures, nanocrystalline film, porous semiconductor, nanocrystals, nanowires and other nano-and microstructures. In the case of wafers, provides information on the homogeneity of their electronic characteristics, density of dislocations, grain sub frontiers, distribution of impurities and so on. while on the study of heterostructures CL images can determine, for example, the presence of misfit dislocations at the interface between different sheets, below the outer surface of the sample. In the study of other low dimensional structures, such as nanocrystalline films, nanoparticles and nano-and microstructures are observed elongated in some cases quantum confinement effects from the CL spectra. Moreover, larger structures, the order of hundreds of nanometers, with forms of wires, tubes or strips, is that in many semiconductor materials, mainly oxides, the behavior of luminescence is different from bulk material. The microstructures have a different structure of defects and a greater influence of the surface, which in some cases leads to a higher emission efficiency and a different spectral distribution. The presentation describes the principle of the CL technique and examples of its application in the characterization of a wide range of both semiconductor materials of different composition, and of different sizes ranging from nanostructures to bulk samples

  12. Closed-Loop Autofocus Scheme for Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Cui Le

    2015-01-01

    Full Text Available In this paper, we present a full scale autofocus approach for scanning electron microscope (SEM. The optimal focus (in-focus position of the microscope is achieved by maximizing the image sharpness using a vision-based closed-loop control scheme. An iterative optimization algorithm has been designed using the sharpness score derived from image gradient information. The proposed method has been implemented and validated using a tungsten gun SEM at various experimental conditions like varying raster scan speed, magnification at real-time. We demonstrate that the proposed autofocus technique is accurate, robust and fast.

  13. Historical evolution toward achieving ultrahigh vacuum in JEOL electron microscopes

    CERN Document Server

    Yoshimura, Nagamitsu

    2014-01-01

    This book describes the developmental history of the vacuum system of the transmission electron microscope (TEM) at the Japan Electron Optics Laboratory (JEOL) from its inception to its use in today’s high-technology microscopes. The author and his colleagues were engaged in developing vacuum technology for electron microscopes (JEM series) at JEOL for many years. This volume presents a summary and explanation of their work and the technology that makes possible a clean ultrahigh vacuum. The typical users of the TEM are top-level researchers working at the frontiers of new materials or with new biological specimens. They often use the TEM under extremely severe conditions, with problems sometimes occurring in the vacuum system of the microscopes. JEOL engineers then must work as quickly as possible to improve the vacuum evacuation system so as to prevent the recurrence of such problems. Among the wealth of explanatory material in this book are examples of users’ reports of problems in the vacuum system of...

  14. Decontamination of digital image sensors and assessment of electron microscope performance in a BSL-3 containment

    Directory of Open Access Journals (Sweden)

    Michael B. Sherman

    2015-05-01

    Full Text Available A unique biological safety level (BSL-3 cryo-electron microscopy facility with a 200 keV high-end cryo-electron microscope has been commissioned at the University of Texas Medical Branch (UTMB to study the structure of viruses and bacteria classified as select agents. We developed a microscope decontamination protocol based on chlorine dioxide gas with a continuous flow system. In this paper we report on testing digital camera sensors (both CCD and CMOS direct detector in a BSL-3 environment, and microscope performance after chlorine dioxide (ClO2 decontamination cycles.

  15. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  16. Analytical electron microscope based on scanning transmission electron microscope with wavelength dispersive x-ray spectroscopy to realize highly sensitive elemental imaging especially for light elements

    International Nuclear Information System (INIS)

    Koguchi, Masanari; Tsuneta, Ruriko; Anan, Yoshihiro; Nakamae, Koji

    2017-01-01

    An analytical electron microscope based on the scanning transmission electron microscope with wavelength dispersive x-ray spectroscopy (STEM-WDX) to realize highly sensitive elemental imaging especially for light elements has been developed. In this study, a large-solid-angle multi-capillary x-rays lens with a focal length of 5 mm, long-time data acquisition (e.g. longer than 26 h), and a drift-free system made it possible to visualize boron-dopant images in a Si substrate at a detection limit of 0.2 atomic percent. (paper)

  17. Transmission environmental scanning electron microscope with scintillation gaseous detection device.

    Science.gov (United States)

    Danilatos, Gerasimos; Kollia, Mary; Dracopoulos, Vassileios

    2015-03-01

    A transmission environmental scanning electron microscope with use of a scintillation gaseous detection device has been implemented. This corresponds to a transmission scanning electron microscope but with addition of a gaseous environment acting both as environmental and detection medium. A commercial type of low vacuum machine has been employed together with appropriate modifications to the detection configuration. This involves controlled screening of various emitted signals in conjunction with a scintillation gaseous detection device already provided with the machine for regular surface imaging. Dark field and bright field imaging has been obtained along with other detection conditions. With a progressive series of modifications and tests, the theory and practice of a novel type of microscopy is briefly shown now ushering further significant improvements and developments in electron microscopy as a whole. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Expression of calcium channel CaV1.3 in cat spinal cord: light and electron microscopic immunohistochemical study

    DEFF Research Database (Denmark)

    Zhang, Mengliang; Møller, Morten; Broman, Jonas

    2008-01-01

    in the cat spinal cord by light and electron microscopic immunohistochemistry. The results show that Ca(V)1.3-like immunoreactivity is widely distributed in all segments of the spinal cord but that the distribution in the different laminae of the spinal gray matter varies, with the highest density of labeled...... enlargements and the phrenic nucleus in cervical, Clarke's nucleus in lower thoracic and upper lumbar, and Onuf's nucleus in upper sacral segments. At the ultrastructural level, Ca(V)1.3-immunoreactive products were found in neuronal somata and dendrites of different sizes. In the soma, they were predominantly...

  19. Microscopic Electron Variations Measured Simultaneously By The Cluster Spacecraft

    Science.gov (United States)

    Buckley, A. M.; Carozzi, T. D.; Gough, M. P.; Beloff, N.

    Data is used from the Particle Correlator experiments running on each of the four Cluster spacecraft so as to determine common microscopic behaviour in the elec- tron population observed over the macroscopic Cluster separations. The Cluster par- ticle correlator experiments operate by forming on board Auto Correlation Functions (ACFs) generated from short time series of electron counts obtained, as a function of electron energy, from the PEACE HEEA sensor. The information on the microscopic variation of the electron flux covers the frequency range DC up to 41 kHz (encom- passing typical electron plasma frequencies and electron gyro frequencies and their harmonics), the electron energy range is that covered by the PEACE HEEA sensor (within the range 1 eV to 26 keV). Results are presented of coherent electron struc- tures observed simultaneously by the four spacecraft in the differing plasma interac- tion regions and boundaries encountered by Cluster. As an aid to understanding the plasma interactions, use is made of numerical simulations which model both the un- derlying statistical properties of the electrons and also the manner in which particle correlator experiments operate.

  20. Acute radiation nephritis. Light and electron microscopic observations

    International Nuclear Information System (INIS)

    Kapur, S.; Chandra, R.; Antonovych, T.

    1977-01-01

    Light and electron microscopy were used to observe acute radiation nephritis. By light microscopy the changes were of fibrinoid necrosis of the arteries and arterioles with segmental necrosis of the glomerular tufts. By electron microscopy the endocapillary cells reacted by hypertrophy and hyperplasia with increase in cytoplasmic organelles. In addition, disruption of endothelial and epithelial cells from the basement membranes were seen. It is concluded that the electron microscopic changes were unique and may be helpful in differentiating the necrotizing glomerulitis seen in other conditions, especially malignant hypertension

  1. Foucault imaging by using non-dedicated transmission electron microscope

    International Nuclear Information System (INIS)

    Taniguchi, Yoshifumi; Matsumoto, Hiroaki; Harada, Ken

    2012-01-01

    An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.

  2. Foucault imaging by using non-dedicated transmission electron microscope

    Science.gov (United States)

    Taniguchi, Yoshifumi; Matsumoto, Hiroaki; Harada, Ken

    2012-08-01

    An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.

  3. Foucault imaging by using non-dedicated transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Taniguchi, Yoshifumi [Science and Medical Systems Business Group, Hitachi High-Technologies Corp., Ichige, Hitachinaka, Ibaraki 312-8504 (Japan); Matsumoto, Hiroaki [Corporate Manufacturing Strategy Group, Hitachi High-Technologies Corp., Ishikawa-cho, Hitachinaka, Ibaraki 312-1991 (Japan); Harada, Ken [Central Research Laboratory, Hitachi Ltd., Hatoyama, Saitama 350-0395 (Japan)

    2012-08-27

    An electron optical system for observing Foucault images was constructed using a conventional transmission electron microscope without any special equipment for Lorentz microscopy. The objective lens was switched off and an electron beam was converged by a condenser optical system to the crossover on the selected area aperture plane. The selected area aperture was used as an objective aperture to select the deflected beam for Foucault mode, and the successive image-forming lenses were controlled for observation of the specimen images. The irradiation area on the specimen was controlled by selecting the appropriate diameter of the condenser aperture.

  4. Electron beam dynamics in an ultrafast transmission electron microscope with Wehnelt electrode

    Energy Technology Data Exchange (ETDEWEB)

    Bücker, K.; Picher, M.; Crégut, O. [Institut de Physique et Chimie des Matériaux de Strasbourg, UMR 7504 CNRS, Université de Strasbourg, 23 rue du Loess, 67034 Strasbourg (France); LaGrange, T. [Interdisciplinary Centre for Electron Microscopy, École Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland); Reed, B.W.; Park, S.T.; Masiel, D.J. [Integrated Dynamic Electron Solutions, Inc., 5653 Stoneridge Drive 117, Pleasanton, CA 94588 (United States); Banhart, F., E-mail: florian.banhart@ipcms.unistra.fr [Institut de Physique et Chimie des Matériaux de Strasbourg, UMR 7504 CNRS, Université de Strasbourg, 23 rue du Loess, 67034 Strasbourg (France)

    2016-12-15

    High temporal resolution transmission electron microscopy techniques have shown significant progress in recent years. Using photoelectron pulses induced by ultrashort laser pulses on the cathode, these methods can probe ultrafast materials processes and have revealed numerous dynamic phenomena at the nanoscale. Most recently, the technique has been implemented in standard thermionic electron microscopes that provide a flexible platform for studying material's dynamics over a wide range of spatial and temporal scales. In this study, the electron pulses in such an ultrafast transmission electron microscope are characterized in detail. The microscope is based on a thermionic gun with a Wehnelt electrode and is operated in a stroboscopic photoelectron mode. It is shown that the Wehnelt bias has a decisive influence on the temporal and energy spread of the picosecond electron pulses. Depending on the shape of the cathode and the cathode-Wehnelt distance, different emission patterns with different pulse parameters are obtained. The energy spread of the pulses is determined by space charge and Boersch effects, given by the number of electrons in a pulse. However, filtering effects due to the chromatic aberrations of the Wehnelt electrode allow the extraction of pulses with narrow energy spreads. The temporal spread is governed by electron trajectories of different length and in different electrostatic potentials. High temporal resolution is obtained by excluding shank emission from the cathode and aberration-induced halos in the emission pattern. By varying the cathode-Wehnelt gap, the Wehnelt bias, and the number of photoelectrons in a pulse, tradeoffs between energy and temporal resolution as well as beam intensity can be made as needed for experiments. Based on the characterization of the electron pulses, the optimal conditions for the operation of ultrafast TEMs with thermionic gun assembly are elaborated. - Highlights: • A detailed characterization of electron

  5. The ultrastructural changes in the liver cells induced by high doses of Benzodiazepine Tranquilizing drugs: An experimental transmission electron microscopic study on male guinea pigs

    International Nuclear Information System (INIS)

    Bisher, Ameen S. Ahmad

    2008-01-01

    Benzodiazepines are tranquilizing psychotropic drugs. Unfortunately, despite their therapeutic benefits, they are illegally consumed in high doses by some addicts to reach a sedative, exhilarative and euphoria state similar to that produced by narcotic substances. The present study, using transmission electron microscope on male guinea pigs, aims to investigate the potential ultrastructural changes in the liver cells induced by the high doses of Benzodiazepines. Animals in three treated groups administrated a daily combined dose consisted of (10mg Alprazolam with 10mg Diazepam/day/animal) for three different treatment periods: 7, 15, and 25 days. The ultrastructural examination of the hepatocytes of the animals treated for 15 days showed limited changes in the form of marginal heterochromatine accompanied with marginal nucleoli enlargement. On the other hand, severe ultrastructural damages are observed in the animals treated for 25 days, which appeared in the following various patterns: fatty degeneration of the hepatocytes as indicated by the accumulation of large number of lipid droplets in the cytoplasm, marked nuclear atrophy in some necrotic hepatocytes, massive nuclear degeneration in other hepatocytes, mitochondrial damages in the form of cristea destruction accompanied with abnormal oval shape, massive lysis of the cytoplasmic organelles with severe plasma membrane rupture. In conclusion, the observed ultrastructural damages in the present study may refer to the potential hepatotoxic effects of the high dose of Benzodiazepins. It is recommended that much more official restrictions should be applied on the pharmacies sector to prevent any illegal selling of these drugs in order to prevent abusers from obtaining them, as unfortunately in some developing countries the illegal selling of these drugs is known to occur due to the absence of official control. (author)

  6. Scanning electron microscopic studies on antenna of Hemipyrellia ligurriens (Wiedemann, 1830) (Diptera: Calliphoridae)-A blow fly species of forensic importance.

    Science.gov (United States)

    Hore, Garima; Maity, Aniruddha; Naskar, Atanu; Ansar, Waliza; Ghosh, Shyamasree; Saha, Goutam Kumar; Banerjee, Dhriti

    2017-08-01

    Blow flies (Diptera: Calliphoridae) are one of the foremost organisms amongst forensic insects to colonize corpses shortly after death, thus are of immense importance in the domain of forensic entomology. The blow fly Hemipyrellia ligurriens (Wiedemann, 1830) (Diptera: Calliphoridae) is considered as a forensically important fly species globally and is also known for its medical and veterinary importance. In the present study, we report for the first time scanning electron microscopic studies on the morphology of sensilla of antenna of adult male and female of H. ligurriens is with profound importance in better understanding of the insect morphology from forensic entomological perspective, and also could aid in proper identification of the species from other calliphorid flies. The structural peculiarities observed in the (i) antenna of H. ligurriens with three segments- scape, pedicel and flagellum with dorso-laterally placed arista (ii) densely covered microtrichia and most abundant trichoid sensilla identified on the antenna (iii) observation of only one type of sensilla, chaetic sensilla (ChI) on the scape (iv) two types of chaetic sensilla (ChI and ChII) and styloconic sensilla on the pedicel (v) the flagellum with three types of sensilla- trichoid, basiconic and coeloconic sensilla (vi) Basiconic sensilla with multiporous surfaces with characteristic olfactory function. Moderate sexual dimorphism in the width of the flagellum, the females with wider flagella than the males, bear significance to the fact that they bear more multi-porous sensilla than the males, thus suffice their need to detect oviposition sites. Significant difference was observed in the length and width of coeloconic sensilla between the two sexes, the females showed bigger coeloconic sensilla, suggesting their function in oviposition site detection and successful colonization in corpses. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Electron microscope investigation into dislocation structure of cast aluminium alloys

    International Nuclear Information System (INIS)

    Zolotorevskij, V.S.; Orelkina, T.A.; Istomin-Kastrovskij, V.V.

    1978-01-01

    By applying the diffraction electron microscopy method, the general specific features of the disclocation structure of cast binary alloys of aluminium with different additions were established. It is shown that in most alloys, when they undergo cooling in the process of crystallization at the rate of about 850 deg/min, the cellular dislocation structure is formed. It is shown that in all the alloys studied, the total density of dislocations of one order is about-10 9 cm -2 , which exceeds by 1 to 2 orders of magnitude the value which follows from the Tiller theory of concentration stresses. It has been experimentally established that the contribution of shrinkage and thermal stresses to the formation of a dislocation structure is rather insignificant; yet the dislocation density values calculated according to the size of dendritic cells and the medium angles of their disorientation are close to those determined by the electron-microscopic method. This is the basis for making a supposition that the greater part of the dislocations in castings are formed as a result of comparing dendritic branches with one another, which are disoriented in respect to each other

  8. A scanning electron microscope study and statistical analysis of adipocyte morphology in lipofilling: comparing the effects of harvesting and purification procedures with 2 different techniques.

    Science.gov (United States)

    Rubino, Corrado; Mazzarello, Vittorio; Faenza, Mario; Montella, Andrea; Santanelli, Fabio; Farace, Francesco

    2015-06-01

    The aim of this study was to evaluate the effects on adipocyte morphology of 2 techniques of fat harvesting and of fat purification in lipofilling, considering that the number of viable healthy adipocytes is important in fat survival in recipient areas of lipofilling. Fat harvesting was performed in 10 female patients from flanks, on one side with a 2-mm Coleman cannula and on the other side with a 3-mm Mercedes cannula. Thirty milliliter of fat tissue from each side was collected and divided into three 10 mL syringes: A, B, and C. The fat inside syringe A was left untreated, the fat in syringe B underwent simple sedimentation, and the fat inside syringe C underwent centrifugation at 3000 rpm for 3 minutes. Each fat graft specimen was processed for examination under low-vacuum scanning electron microscope. Diameter (μ) and number of adipocytes per square millimeter and number of altered adipocytes per square millimeter were evaluated. Untreated specimens harvested with the 2 different techniques were first compared, then sedimented versus centrifuged specimens harvested with the same technique were compared. Statistical analysis was performed using Wilcoxon signed rank test. The number of adipocytes per square millimeter was statistically higher in specimens harvested with the 3-mm Mercedes cannula (P = 0.0310). The number of altered cells was statistically higher in centrifuged specimens than in sedimented ones using both methods of fat harvesting (P = 0.0080) with a 2-mm Coleman cannula and (P = 0.0050) with a 3-mm Mercedes cannula. Alterations in adipocyte morphology consisted in wrinkling of the membrane, opening of pore with leakage of oily material, reduction of cellular diameter, and total collapse of the cellular membrane. Fat harvesting by a 3-mm cannula results in a higher number of adipocytes and centrifugation of the harvested fat results in a higher number of morphologic altered cells than sedimentation.

  9. Characterization of quantum well structures using a photocathode electron microscope

    Science.gov (United States)

    Spencer, Michael G.; Scott, Craig J.

    1989-01-01

    Present day integrated circuits pose a challenge to conventional electronic and mechanical test methods. Feature sizes in the submicron and nanometric regime require radical approaches in order to facilitate electrical contact to circuits and devices being tested. In addition, microwave operating frequencies require careful attention to distributed effects when considering the electrical signal paths within and external to the device under test. An alternative testing approach which combines the best of electrical and optical time domain testing is presented, namely photocathode electron microscope quantitative voltage contrast (PEMQVC).

  10. A new clustering algorithm for scanning electron microscope images

    Science.gov (United States)

    Yousef, Amr; Duraisamy, Prakash; Karim, Mohammad

    2016-04-01

    A scanning electron microscope (SEM) is a type of electron microscope that produces images of a sample by scanning it with a focused beam of electrons. The electrons interact with the sample atoms, producing various signals that are collected by detectors. The gathered signals contain information about the sample's surface topography and composition. The electron beam is generally scanned in a raster scan pattern, and the beam's position is combined with the detected signal to produce an image. The most common configuration for an SEM produces a single value per pixel, with the results usually rendered as grayscale images. The captured images may be produced with insufficient brightness, anomalous contrast, jagged edges, and poor quality due to low signal-to-noise ratio, grained topography and poor surface details. The segmentation of the SEM images is a tackling problems in the presence of the previously mentioned distortions. In this paper, we are stressing on the clustering of these type of images. In that sense, we evaluate the performance of the well-known unsupervised clustering and classification techniques such as connectivity based clustering (hierarchical clustering), centroid-based clustering, distribution-based clustering and density-based clustering. Furthermore, we propose a new spatial fuzzy clustering technique that works efficiently on this type of images and compare its results against these regular techniques in terms of clustering validation metrics.

  11. Atomic-Resolution Transmission Electron Microscopic Movies for Study of Organic Molecules, Assemblies, and Reactions: The First 10 Years of Development.

    Science.gov (United States)

    Nakamura, Eiichi

    2017-06-20

    A molecule is a quantum mechanical entity. "Watching motions and reactions of a molecule with our eyes" has therefore been a dream of chemists for a century. This dream has come true with the aid of the movies of atomic-resolution transmission electron microscopic (AR-TEM) molecular images through real-time observation of dynamic motions of single organic molecules (denoted hereafter as single-molecule atomic-resolution real-time (SMART) TEM imaging). Since 2007, we have reported movies of a variety of single organic molecules, organometallic molecules, and their assemblies, which are rotating, stretching, and reacting. Like movies in the theater, the atomic-resolution molecular movies provide us information on the 3-D structures of the molecules and also their time evolution. The success of the SMART-TEM imaging crucially depends on the development of "chemical fishhooks" with which fish (organic molecules) in solution can be captured on a single-walled carbon nanotube (CNT, serving as a "fishing rod"). The captured molecules are connected to a slowly vibrating CNT, and their motions are displayed on a monitor in real time. A "fishing line" connecting the fish and the rod may be a σ-bond, a van der Waals force, or other weak connections. Here, the molecule/CNT system behaves as a coupled oscillator, where the low-frequency anisotropic vibration of the CNT is transmitted to the molecules via the weak chemical connections that act as an energy filter. Interpretation of the observed motions of the molecules at atomic resolution needs us to consider the quantum mechanical nature of electrons as well as bond rotation, letting us deviate from the conventional statistical world of chemistry. What new horizons can we explore? We have so far carried out conformational studies of individual molecules, assigning anti or gauche conformations to each C-C bond in conformers that we saw. We can also determine the structures of van der Waals assemblies of organic molecules

  12. Radioactive and electron microscope analysis of effluent monitor sample lines

    International Nuclear Information System (INIS)

    Kowalski, J.F.

    1986-01-01

    Effluent air sampling at nuclear power plant often leads to the question ''How representative is the sample of the effluent stream?'' Samples from radiation monitors are typically obtained at great distances from the sample nozzle because of high background concerns under postulated accidents. Sample line plateout during normal effluent sampling becomes the major concern. A US Nuclear Regulatory Commission inspection raised a concern that monitors were not collecting representative samples per ANSI standard N13.1. A comprehensive 2-yr study at Beaver Valley was performed during normal effluent releases in two phases: 1) weekly charcoal and glass fiber filter samples were analyzed for radioactivity for 6 months, and 2) nuclepore membrane filter samples were analyzed by electron microscope for 4- and 6-h periods. A specially designed test nozzle was directly inserted into an effluent stream for comparison with the radiation monitor samples. Particle behavior characteristics can be determined during effluent releases using a simple test probe. While particle plateout was the major purpose of the study, other particle behavior characteristics were evident and equally as important. Particle travel through long sample lines can also lead to (a) agglomeration or the coagulation of smaller particles to form larger ones, (b) particle splitting or fracturing upon impact with the sample line interior walls, and (c) resuspension of large particles in sample lines

  13. Role of scanning electron microscope )SEM) in metal failure analysis

    International Nuclear Information System (INIS)

    Shaiful Rizam Shamsudin; Hafizal Yazid; Mohd Harun; Siti Selina Abd Hamid; Nadira Kamarudin; Zaiton Selamat; Mohd Shariff Sattar; Muhamad Jalil

    2005-01-01

    Scanning electron microscope (SEM) is a scientific instrument that uses a beam of highly energetic electrons to examine the surface and phase distribution of specimens on a micro scale through the live imaging of secondary electrons (SE) and back-scattered electrons (BSE) images. One of the main activities of SEM Laboratory at MINT is for failure analysis on metal part and components. The capability of SEM is excellent for determining the root cause of metal failures such as ductility or brittleness, stress corrosion, fatigue and other types of failures. Most of our customers that request for failure analysis are from local petrochemical plants, manufacturers of automotive components, pipeline maintenance personnel and engineers who involved in the development of metal parts and component. This paper intends to discuss some of the technical concepts in failure analysis associated with SEM. (Author)

  14. Electron irradiation-induced destruction of carbon nanotubes in electron microscopes

    International Nuclear Information System (INIS)

    Molhave, Kristian; Gudnason, Sven Bjarke; Pedersen, Anders Tegtmeier; Clausen, Casper Hyttel; Horsewell, Andy; Boggild, Peter

    2007-01-01

    Observations of carbon nanotubes under exposure to electron beam irradiation in standard transmission electron microscope (TEM) and scanning electron microscope (SEM) systems show that such treatment in some cases can cause severe damage of the nanotube structure, even at electron energies far below the approximate 100 keV threshold for knock-on damage displacing carbon atoms in the graphene structure. We find that the damage we observe in one TEM can be avoided by use of a cold finger. This and the morphology of the damage imply that water vapour, which is present as a background gas in many vacuum chambers, can damage the nanotube structure through electron beam-induced chemical reactions. Though, the dependence on the background gas makes these observations specific for the presently used systems, the results demonstrate the importance of careful assessment of the level of subtle structural damage that the individual electron microscope system can do to nanostructures during standard use

  15. Cooled CCDs for recording data from electron microscopes

    CERN Document Server

    Faruqi, A R

    2000-01-01

    A cooled-CCD camera based on a low-noise scientific grade device is described in this paper used for recording images in a 120 kV electron microscope. The primary use of the camera is for recording electron diffraction patterns from two-dimensionally ordered arrays of proteins at liquid-nitrogen temperatures leading to structure determination at atomic or near-atomic resolution. The traditional method for recording data in the microscope is with electron sensitive film but electronic detection methods offer the following advantages over film methods: the data is immediately available in a digital format which can be displayed on a monitor screen for visual inspection whereas a film record needs to be developed and digitised, a lengthy process taking at least several hours, prior to inspection; the dynamic range of CCD detectors is about two orders of magnitude greater with better linearity. The accuracy of measurements is also higher for CCDs, particularly for weak signals due to inherent fog levels in film. ...

  16. Photocathode Optimization for a Dynamic Transmission Electron Microscope: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, P; Flom, Z; Heinselman, K; Nguyen, T; Tung, S; Haskell, R; Reed, B W; LaGrange, T

    2011-08-04

    The Dynamic Transmission Electron Microscope (DTEM) team at Harvey Mudd College has been sponsored by LLNL to design and build a test setup for optimizing the performance of the DTEM's electron source. Unlike a traditional TEM, the DTEM achieves much faster exposure times by using photoemission from a photocathode to produce electrons for imaging. The DTEM team's work is motivated by the need to improve the coherence and current density of the electron cloud produced by the electron gun in order to increase the image resolution and contrast achievable by DTEM. The photoemission test setup is nearly complete and the team will soon complete baseline tests of electron gun performance. The photoemission laser and high voltage power supply have been repaired; the optics path for relaying the laser to the photocathode has been finalized, assembled, and aligned; the internal setup of the vacuum chamber has been finalized and mostly implemented; and system control, synchronization, and data acquisition has been implemented in LabVIEW. Immediate future work includes determining a consistent alignment procedure to place the laser waist on the photocathode, and taking baseline performance measurements of the tantalum photocathode. Future research will examine the performance of the electron gun as a function of the photoemission laser profile, the photocathode material, and the geometry and voltages of the accelerating and focusing components in the electron gun. This report presents the team's progress and outlines the work that remains.

  17. In situ laser processing in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Nicholas A.; Magel, Gregory A.; Hartfield, Cheryl D.; Moore, Thomas M.; Fowlkes, Jason D.; Rack, Philip D. [Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States) and Omniprobe, Inc., an Oxford Instruments Company, 10410 Miller Rd., Dallas, Texas 75238 (United States); Omniprobe, Inc., an Oxford Instruments Company, 10410 Miller Rd., Dallas, Texas 75238 (United States); Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Department of Materials Science and Engineering, University of Tennessee, Knoxville, Tennessee 37996 (United States) and Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2012-07-15

    Laser delivery probes using multimode fiber optic delivery and bulk focusing optics have been constructed and used for performing materials processing experiments within scanning electron microscope/focused ion beam instruments. Controlling the current driving a 915-nm semiconductor diode laser module enables continuous or pulsed operation down to sub-microsecond durations, and with spot sizes on the order of 50 {mu}m diameter, achieving irradiances at a sample surface exceeding 1 MW/cm{sup 2}. Localized laser heating has been used to demonstrate laser chemical vapor deposition of Pt, surface melting of silicon, enhanced purity, and resistivity via laser annealing of Au deposits formed by electron beam induced deposition, and in situ secondary electron imaging of laser induced dewetting of Au metal films on SiO{sub x}.

  18. Characteristics of different frequency ranges in scanning electron microscope images

    International Nuclear Information System (INIS)

    Sim, K. S.; Nia, M. E.; Tan, T. L.; Tso, C. P.; Ee, C. S.

    2015-01-01

    We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement

  19. Characteristics of different frequency ranges in scanning electron microscope images

    Energy Technology Data Exchange (ETDEWEB)

    Sim, K. S., E-mail: kssim@mmu.edu.my; Nia, M. E.; Tan, T. L.; Tso, C. P.; Ee, C. S. [Faculty of Engineering and Technology, Multimedia University, 75450 Melaka (Malaysia)

    2015-07-22

    We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.

  20. Visualizing Morphological Changes of Abscission Zone Cells in Arabidopsis by Scanning Electron Microscope.

    Science.gov (United States)

    Shi, Chun-Lin; Butenko, Melinka A

    2018-01-01

    Scanning electron microscope (SEM) is a type of electron microscope which produces detailed images of surface structures. It has been widely used in plants and animals to study cellular structures. Here, we describe a detailed protocol to prepare samples of floral abscission zones (AZs) for SEM, as well as further image analysis. We show that it is a powerful tool to detect morphologic changes at the cellular level during the course of abscission in wild-type plants and to establish the details of phenotypic alteration in abscission mutants.

  1. Electric field stimulation setup for photoemission electron microscopes.

    Science.gov (United States)

    Buzzi, M; Vaz, C A F; Raabe, J; Nolting, F

    2015-08-01

    Manipulating magnetisation by the application of an electric field in magnetoelectric multiferroics represents a timely issue due to the potential applications in low power electronics and the novel physics involved. Thanks to its element sensitivity and high spatial resolution, X-ray photoemission electron microscopy is a uniquely suited technique for the investigation of magnetoelectric coupling in multiferroic materials. In this work, we present a setup that allows for the application of in situ electric and magnetic fields while the sample is analysed in the microscope. As an example of the performances of the setup, we present measurements on Ni/Pb(Mg(0.66)Nb(0.33))O3-PbTiO3 and La(0.7)Sr(0.3)MnO3/PMN-PT artificial multiferroic nanostructures.

  2. Resizing metal-coated nanopores using a scanning electron microscope.

    Science.gov (United States)

    Chansin, Guillaume A T; Hong, Jongin; Dusting, Jonathan; deMello, Andrew J; Albrecht, Tim; Edel, Joshua B

    2011-10-04

    Electron beam-induced shrinkage provides a convenient way of resizing solid-state nanopores in Si(3) N(4) membranes. Here, a scanning electron microscope (SEM) has been used to resize a range of different focussed ion beam-milled nanopores in Al-coated Si(3) N(4) membranes. Energy-dispersive X-ray spectra and SEM images acquired during resizing highlight that a time-variant carbon deposition process is the dominant mechanism of pore shrinkage, although granular structures on the membrane surface in the vicinity of the pores suggest that competing processes may occur. Shrinkage is observed on the Al side of the pore as well as on the Si(3) N(4) side, while the shrinkage rate is observed to be dependent on a variety of factors. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Spinning Carbon Nanotube Nanothread under a Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Mark Schulz

    2011-08-01

    Full Text Available Nanothread with a diameter as small as one hundred nanometers was manufactured under a scanning electron microscope. Made directly from carbon nanotubes, and inheriting their superior electrical and mechanical properties, nanothread may be the world’s smallest man-made fiber. The smallest thread that can be spun using a bench-top spinning machine is about 5 microns in diameter. Nanothread is a new material building block that can be used at the nanoscale or plied to form yarn for applications at the micro and macro scales. Preliminary electrical and mechanical properties of nanothread were measured. The resistivity of nanothread is less than 10−5 Ω∙m. The strength of nanothread is greater than 0.5 GPa. This strength was obtained from measurements using special glue that cures in an electron microscope. The glue weakened the thread, thus further work is needed to obtain more accurate measurements. Nanothread will have broad applications in enabling electrical components, circuits, sensors, and tiny machines. Yarn can be used for various macroscale applications including lightweight antennas, composites, and cables.

  4. Energy-weighted dynamical scattering simulations of electron diffraction modalities in the scanning electron microscope.

    Science.gov (United States)

    Pascal, Elena; Singh, Saransh; Callahan, Patrick G; Hourahine, Ben; Trager-Cowan, Carol; Graef, Marc De

    2018-04-01

    Transmission Kikuchi diffraction (TKD) has been gaining momentum as a high resolution alternative to electron back-scattered diffraction (EBSD), adding to the existing electron diffraction modalities in the scanning electron microscope (SEM). The image simulation of any of these measurement techniques requires an energy dependent diffraction model for which, in turn, knowledge of electron energies and diffraction distances distributions is required. We identify the sample-detector geometry and the effect of inelastic events on the diffracting electron beam as the important factors to be considered when predicting these distributions. However, tractable models taking into account inelastic scattering explicitly are lacking. In this study, we expand the Monte Carlo (MC) energy-weighting dynamical simulations models used for EBSD [1] and ECP [2] to the TKD case. We show that the foil thickness in TKD can be used as a means of energy filtering and compare band sharpness in the different modalities. The current model is shown to correctly predict TKD patterns and, through the dictionary indexing approach, to produce higher quality indexed TKD maps than conventional Hough transform approach, especially close to grain boundaries. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Development of a secondary electron energy analyzer for a transmission electron microscope.

    Science.gov (United States)

    Magara, Hideyuki; Tomita, Takeshi; Kondo, Yukihito; Sato, Takafumi; Akase, Zentaro; Shindo, Daisuke

    2018-04-01

    A secondary electron (SE) energy analyzer was developed for a transmission electron microscope. The analyzer comprises a microchannel plate (MCP) for detecting electrons, a coil for collecting SEs emitted from the specimen, a tube for reducing the number of backscattered electrons incident on the MCP, and a retarding mesh for selecting the energy of SEs incident on the MCP. The detection of the SEs associated with charging phenomena around a charged specimen was attempted by performing electron holography and SE spectroscopy using the energy analyzer. The results suggest that it is possible to obtain the energy spectra of SEs using the analyzer and the charging states of a specimen by electron holography simultaneously.

  6. Damage-free vibrational spectroscopy of biological materials in the electron microscope.

    Science.gov (United States)

    Rez, Peter; Aoki, Toshihiro; March, Katia; Gur, Dvir; Krivanek, Ondrej L; Dellby, Niklas; Lovejoy, Tracy C; Wolf, Sharon G; Cohen, Hagai

    2016-03-10

    Vibrational spectroscopy in the electron microscope would be transformative in the study of biological samples, provided that radiation damage could be prevented. However, electron beams typically create high-energy excitations that severely accelerate sample degradation. Here this major difficulty is overcome using an 'aloof' electron beam, positioned tens of nanometres away from the sample: high-energy excitations are suppressed, while vibrational modes of energies electron energy loss spectra from biogenic guanine crystals in their native state, resolving their characteristic C-H, N-H and C=O vibrational signatures with no observable radiation damage. The technique opens up the possibility of non-damaging compositional analyses of organic functional groups, including non-crystalline biological materials, at a spatial resolution of ∼10 nm, simultaneously combined with imaging in the electron microscope.

  7. Microscopic hydrodynamics study with nuclear track membrane

    International Nuclear Information System (INIS)

    Shilun Guo; Yuhua Zhao; Yulan Wang; Hiuhong Hao; Brandt, R.; Vater, P.

    1988-01-01

    Microscopic hydrodynamics has been studied using different liquids and nuclear track membranes with pores perpendicularly piercing through them. The flow rate of water and alcohol has been studied with polycarbonate track membranes with pore diameters 1.48 micrometres and 1.08 micrometres. It has been shown that the flow rate both for water and alcohol on a microscopic scale can be determined by the Poiseuille law which characterizes macroscopic laminar flow. The Reynolds number used in macroscopic fluid flow has been calculated from the flow rate and parameters of the liquids and the geometry of the pores. It has been shown that this Reynolds number can also be used to characterize microscopic flow. Based on the above results, the filtration capacity (or limit) of polycarbonate track microfilters for water had been calculated. Some possible limits on the application of the calculation are pointed out and discussed. (author)

  8. Electron microscopic in situ study of phase and defect formation in Bi2Sr2CaCu2Oy single crystals in heating

    International Nuclear Information System (INIS)

    Goncharov, V.A.; Ignat'eva, E.Yu.; Osip'yan, Yu.A.; Suvorov, Eh.V.

    1997-01-01

    The nonthermal effect of electron irradiation on generating of new phases and structural defects has been uncovered during the investigation of structural variations of monocrystals Bi 2 Sr 2 CaCu 2 O y on heating in situ. The stability of the modulated structure and the package defects to heating under the electron beam action and in the absence of the irradiation has been studied

  9. Simulation and Characterization of a Miniaturized Scanning Electron Microscope

    Science.gov (United States)

    Gaskin, Jessica A.; Jerman, Gregory A.; Medley, Stephanie; Gregory, Don; Abbott, Terry O.; Sampson, Allen R.

    2011-01-01

    A miniaturized Scanning Electron Microscope (mSEM) for in-situ lunar investigations is being developed at NASA Marshall Space Flight Center with colleagues from the University of Alabama in Huntsville (UAH), Advanced Research Systems (ARS), the University of Tennessee in Knoxville (UTK) and Case Western Reserve University (CWRU). This effort focuses on the characterization of individual components of the mSEM and simulation of the complete system. SEMs can provide information on the size, shape, morphology and chemical composition of lunar regolith. Understanding these basic properties will allow us to better estimate the challenges associated with In-Situ Resource Utilization and to improve our basic science knowledge of the lunar surface (either precluding the need for sample return or allowing differentiation of unique samples to be returned to Earth.) The main components of the mSEM prototype includes: a cold field emission electron gun (CFEG), focusing lens, deflection/scanning system and backscatter electron detector. Of these, the electron gun development is of particular importance as it dictates much of the design of the remaining components. A CFEG was chosen for use with the lunar mSEM as its emission does not depend on heating of the tungsten emitter (lower power), it offers a long operation lifetime, is orders of magnitude brighter than tungsten hairpin guns, has a small source size and exhibits low beam energy spread.

  10. Field Emission Scanning Electron Microscope (FESEM) Facility in BTI

    International Nuclear Information System (INIS)

    Cik Rohaida Che Hak; Foo, C.T.; Nor Azillah Fatimah Othman

    2015-01-01

    Field Emission Scanning Electron Microscope (FE-SEM) provides ultra-high resolution imaging at low accelerating voltages and small working distances. The GeminisSEM 500, a new FESEM imaging facility will be installed soon in MTEC, BTI. It provides resolution of the images is as low as 0.6 nm at 15 kV and 1.2 nm at 1 kV, allowing examination of the top surface of nano powders, nano film and nano fiber in the wide range of applications such as mineralogy, ceramics, polymer, metallurgy, electronic devices, chemistry, physics and life sciences. This system is equipped with several detectors to detect various signals such as secondary electrons (SE) detector for topographic information and back-scattered electrons (BSE) detector for materials composition contrast. Energy dispersive x-ray spectroscopy (EDS) with detector energy resolution of < 129 eV and detection limit in the range of 1000-3000 ppm coupled with FE-SEM is used to determine the chemical composition of micro-features including boron (B) to uranium (U). Wavelength dispersive x-ray spectroscopy (WDS) which has detector resolution of 2-20 eV and detection limit of 30-300 ppm coupled with FE-SEM is used to detect elements that cannot be resolved with EDS. The ultra-high resolution imaging combined with the high sensitivity WDS helps to resolve the thorium and rare earth elemental analysis. (author)

  11. Microstructure of steel X 20 Cr 13 in the electron microscopical picture

    International Nuclear Information System (INIS)

    Gesatzke, W.

    1982-01-01

    The tempered microstructure of the steel X 20 Cr 13 is described by an electron microscopical overall picture and additional information is gained which would not be possible with the optical microscope. The large transmission area permits one to quantitatively evaluate a microstructure component which due to its small size can only be measured with electron microscope pictures. (orig.) [de

  12. Electron microscopic identification of Zinga virus as a strain of Rift Valley fever virus.

    Science.gov (United States)

    Olaleye, O D; Baigent, C L; Mueller, G; Tomori, O; Schmitz, H

    1992-01-01

    Electron microscopic examination of a negatively stained suspension of Zinga virus showed particles 90-100 nm in diameter, enveloped with spikes 12-20 nm in length and 5 nm in diameter. Further identification of the virus by immune electron microscopy showed the reactivity of human Rift Valley fever virus-positive serum with Zinga virus. Results of this study are in agreement with earlier reports that Zinga virus is a strain of Rift Valley fever virus.

  13. Evaluation of the incidence of microcracks caused by Mtwo and ProTaper Next rotary file systems versus the self-adjusting file: A scanning electron microscopic study.

    Science.gov (United States)

    Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep

    2017-01-01

    To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group ( n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. The highest incidence of microcracks were associated with the ProTaper Next group, 80% ( P = 0.00), followed by the Mtwo group, 70% ( P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% ( P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups ( P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups ( P = 0.000) as well as the Mtwo and self-adjusting file groups ( P = 0.000). All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.

  14. Survival of plant tissue at super-low temperatures v. An electron microscope study of ice in cortical cells cooled rapidly.

    Science.gov (United States)

    Sakai, A; Otsuka, K

    1967-12-01

    Experiments were carried out with cortical cells in twig bark of mulberry trees in winter in order to clarify the mechanism of survival at super-low temperatures with rapid cooling and rewarming. Attention was given to the relation between the existence of intracellular ice crystals and survival.Cortical cells were cooled rapidly by direct immersion into liquid nitrogen or isopentane cooled at various temperatures. After immersion, they were freeze-substituted with absolute ethanol at -78 degrees . They were then embedded, sectioned and examined under the electron microscope for the presence and distribution of cavities left after ice removal.Cells were found to remain alive and contain no ice cavities when immersed rapidly into isopentane baths kept below -60 degrees . Those cells at intermediate temperatures from -20 degrees to -45 degrees , were almost all destroyed. It was also observed that many ice cavities were contained in the cells immersed rapidly into isopentane baths at -30 degrees . The data seem to indicate that no ice crystals were formed when cooled rapidly by direct immersion into isopentane baths below -60 degrees or into liquid nitrogen.The tissue sections immersed in liquid nitrogen were rapidly transferred to isopentane baths at temperatures ranging from -70 degrees to -10 degrees before rapid rewarming. There was little damage when samples were held at temperatures below -50 degrees for 10 minutes or below -60 degrees for 16 hours. No cavities were found in these cells. Above -45 degrees , and especially at -30 degrees , however, all cells were completely destroyed even when exposed only for 1 minute. Many ice cavities were observed throughout these cells. The results obtained may be explained in terms of the growth rate of intracellular ice crystals.

  15. Large area fabrication of plasmonic nanoparticle grating structure by conventional scanning electron microscope

    International Nuclear Information System (INIS)

    Sudheer,; Tiwari, P.; Rai, V. N.; Srivastava, A. K.; Mukharjee, C.

    2015-01-01

    Plasmonic nanoparticle grating (PNG) structure of different periods has been fabricated by electron beam lithography using silver halide based transmission electron microscope film as a substrate. Conventional scanning electron microscope is used as a fabrication tool for electron beam lithography. Optical microscope and energy dispersive spectroscopy (EDS) have been used for its morphological and elemental characterization. Optical characterization is performed by UV-Vis absorption spectroscopic technique

  16. Permanent magnet finger-size scanning electron microscope columns

    Energy Technology Data Exchange (ETDEWEB)

    Nelliyan, K., E-mail: elenk@nus.edu.sg [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore); Khursheed, A. [Department of Electrical and Computer Engineering, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore)

    2011-07-21

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  17. Permanent magnet finger-size scanning electron microscope columns

    International Nuclear Information System (INIS)

    Nelliyan, K.; Khursheed, A.

    2011-01-01

    This paper presents permanent magnet scanning electron microscope (SEM) designs for both tungsten and field emission guns. Each column makes use of permanent magnet technology and operates at a fixed primary beam voltage. A prototype column operating at a beam voltage of 15 kV was made and tested inside the specimen chamber of a conventional SEM. A small electrostatic stigmator unit and dedicated scanning coils were integrated into the column. The scan coils were wound directly around the objective lens iron core in order to reduce its size. Preliminary experimental images of a test grid specimen were obtained through the prototype finger-size column, demonstrating that it is in principle feasible.

  18. Trichomes of Cannabis sativa as viewed with scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ledbetter, M C; Krikorian, A D

    1975-06-01

    Direct examination of fresh, unfixed and uncoated specimens from vegetative and floral parts of Cannabis sativa with the scanning electron microscope enables one to obtain a faithful representation of their surface morphology. The presence of two major types of trichomes has been confirmed: a glandular type comprising or terminating in a globoid structure, and a conically-shaped nonglandular type. Moreover, three or possibly four distinct glandular types can be distinguished: sessile globoid, small-stalked and large-stalked globoid, and a peltate type. The nonglandular trichomes can be distinguished by the nature of their surfaces: those with a warty surface, and those which are relatively smooth. The range of size and distribution, and the special features of all these types of trichomes are also provided.

  19. Transmission electron microscope sample holder with optical features

    Science.gov (United States)

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  20. A scanning electron microscopic investigation of ceramic orthodontic brackets

    International Nuclear Information System (INIS)

    McDonald, F.; Toms, A.P.

    1990-01-01

    Ceramic brackets were introduced to overcome the esthetic disadvantages of stainless steel brackets. The clinical impression of these brackets is very favorable. However, the sliding mechanics used in the Straightwire (A Company, San Diego, CA, USA) system appear to produce slower tooth movements with ceramic compared to stainless steel brackets. To determine whether this was due to any obvious mechanical problem in the bracket slot, Transcend (Unitek Corporation/3M, Monrovia, CA, USA) ceramic brackets were examined by a scanning electron microscope and compared to stainless steel brackets.Consistently, large surface defects were found in the ceramic bracket slots that were not present in the metal bracket slots. These irregularities could obviously hinder the sliding mechanics of the bracket slot-archwire system and create a greater demand on anchorage. Conversely, the fitting surface of the Transcend ceramic bracket showed extremely smooth surface characteristics, and it would seem advisable for the manufacturers to incorporate this surface within the bracket slot. (author)

  1. Contained scanning electron microscope facility for examining radioactive materials

    International Nuclear Information System (INIS)

    Hsu, C.W.

    1986-03-01

    At the Savannah River Laboratory (SRL) radioactive solids are characterized with a scanning electron microscope (SEM) contained in a glove box. The system includes a research-grade Cambridge S-250 SEM, a Tracor Northern TN-5500 x-ray and image analyzer, and a Microspec wavelength-dispersive x-ray analyzer. The containment facility has a glove box train for mounting and coating samples, and for housing the SEM column, x-ray detectors, and vacuum pumps. The control consoles of the instruments are located outside the glove boxes. This facility has been actively used since October 1983 for high alpha-activity materials such as plutonium metal and plutonium oxide powders. Radioactive defense waste glasses and contaminated equipment have also been examined. During this period the facility had no safety-related incidents, and personnel radiation exposures were maintained at less than 100 mrems

  2. Structural Fingerprinting of Nanocrystals in the Transmission Electron Microscope

    Science.gov (United States)

    Rouvimov, Sergei; Plachinda, Pavel; Moeck, Peter

    2010-03-01

    Three novel strategies for the structurally identification of nanocrystals in a transmission electron microscope are presented. Either a single high-resolution transmission electron microscopy image [1] or a single precession electron diffractogram (PED) [2] may be employed. PEDs from fine-grained crystal powders may also be utilized. Automation of the former two strategies is in progress and shall lead to statistically significant results on ensembles of nanocrystals. Open-access databases such as the Crystallography Open Database which provides more than 81,500 crystal structure data sets [3] or its mainly inorganic and educational subsets [4] may be utilized. [1] http://www.scientificjournals.org/journals 2007/j/of/dissertation.htm [2] P. Moeck and S. Rouvimov, in: {Drugs and the Pharmaceutical Sciences}, Vol. 191, 2009, 270-313 [3] http://cod.ibt.lt, http://www.crystallography.net, http://cod.ensicaen.fr, http://nanocrystallography.org, http://nanocrystallography.net, http://journals.iucr.org/j/issues/2009/04/00/kk5039/kk5039.pdf [4] http://nanocrystallography.research.pdx.edu/CIF-searchable

  3. Electron beam excitation assisted optical microscope with ultra-high resolution.

    Science.gov (United States)

    Inami, Wataru; Nakajima, Kentaro; Miyakawa, Atsuo; Kawata, Yoshimasa

    2010-06-07

    We propose electron beam excitation assisted optical microscope, and demonstrated its resolution higher than 50 nm. In the microscope, a light source in a few nanometers size is excited by focused electron beam in a luminescent film. The microscope makes it possible to observe dynamic behavior of living biological specimens in various surroundings, such as air or liquids. Scan speed of the nanometric light source is faster than that in conventional near-field scanning optical microscopes. The microscope enables to observe optical constants such as absorption, refractive index, polarization, and their dynamic behavior on a nanometric scale. The microscope opens new microscopy applications in nano-technology and nano-science.

  4. Ultra low-K shrinkage behavior when under electron beam in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Lorut, F.; Imbert, G. [ST Microelectronics, 850 rue Jean Monnet, 38926 Crolles Cedex (France); Roggero, A. [Centre National d' Etudes Spatiales, 18 Avenue Edouard Belin, 31400 Toulouse (France)

    2013-08-28

    In this paper, we investigate the tendency of porous low-K dielectrics (also named Ultra Low-K, ULK) behavior to shrink when exposed to the electron beam of a scanning electron microscope. Various experimental electron beam conditions have been used for irradiating ULK thin films, and the resulting shrinkage has been measured through use of an atomic force microscope tool. We report the shrinkage to be a fast, cumulative, and dose dependent effect. Correlation of the shrinkage with incident electron beam energy loss has also been evidenced. The chemical modification of the ULK films within the interaction volume has been demonstrated, with a densification of the layer and a loss of carbon and hydrogen elements being observed.

  5. Atomic imaging using secondary electrons in a scanning transmission electron microscope: experimental observations and possible mechanisms.

    Science.gov (United States)

    Inada, H; Su, D; Egerton, R F; Konno, M; Wu, L; Ciston, J; Wall, J; Zhu, Y

    2011-06-01

    We report detailed investigation of high-resolution imaging using secondary electrons (SE) with a sub-nanometer probe in an aberration-corrected transmission electron microscope, Hitachi HD2700C. This instrument also allows us to acquire the corresponding annular dark-field (ADF) images both simultaneously and separately. We demonstrate that atomic SE imaging is achievable for a wide range of elements, from uranium to carbon. Using the ADF images as a reference, we studied the SE image intensity and contrast as functions of applied bias, atomic number, crystal tilt, and thickness to shed light on the origin of the unexpected ultrahigh resolution in SE imaging. We have also demonstrated that the SE signal is sensitive to the terminating species at a crystal surface. A possible mechanism for atomic-scale SE imaging is proposed. The ability to image both the surface and bulk of a sample at atomic-scale is unprecedented, and can have important applications in the field of electron microscopy and materials characterization. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Light and scanning electron microscopic examination of hair in Garlic's syndrome

    International Nuclear Information System (INIS)

    Celik, Hakan H.; Tunali, S.; Tatar, I.; Aldur, Muhammad M.; Tore, H.

    2007-01-01

    Grisceli syndrome is a rare disease is a rare disease characterized by pigment dilution, partial albinism, variable cellular immunodeficiency and an acute phase of uncontrolled T-lymphocyte macrophage activation. Griscelli et al described this syndrome in 1978. Since then, only approximately, 60 cases have been reported, most from Turkish and Mediterranean population. In microscopic examination, silvery grey hair with large clumped melanosomes on the hair shaft is the diagnostic finding. Here, we present scanning electron microscopic study of hair in 2 cases of Griscelli syndrome where the hair showed normal cuticular pattern but nodular structures were present as an abnormal finding. (author)

  7. Advances in imaging and electron physics the scanning transmission electron microscope

    CERN Document Server

    Hawkes, Peter W

    2009-01-01

    Advances in Imaging and Electron Physics merges two long-running serials--Advances in Electronics and Electron Physics and Advances in Optical and Electron Microscopy. This series features extended articles on the physics of electron devices (especially semiconductor devices), particle optics at high and low energies, microlithography, image science and digital image processing, electromagnetic wave propagation, electron microscopy, and the computing methods used in all these domains.  This particular volume presents several timely articles on the scanning transmission electron microscope. Updated with contributions from leading international scholars and industry experts Discusses hot topic areas and presents current and future research trends Provides an invaluable reference and guide for physicists, engineers and mathematicians.

  8. Imaging of soft and hard materials using a Boersch phase plate in a transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Alloyeau, D., E-mail: alloyeau.damien@gmail.com [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS/72, Berkeley, CA 94720 (United States); Hsieh, W.K. [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS/72, Berkeley, CA 94720 (United States); Anderson, E.H.; Hilken, L. [Center for X-ray Optics, Lawrence Berkeley National Laboratory, Berkeley CA 94720 (United States); Benner, G. [Carl Zeiss NTS GmbH, Oberkochen 73447 (Germany); Meng, X. [Electrical Engineering and Computer Sciences, UC Berkeley, Berkeley, CA 94720-1770 (United States); Chen, F.R. [Department of Engineering and System Science, National Tsing Hua University, Hsinchu, Taiwan (China); Kisielowski, C. [National Center for Electron Microscopy, Lawrence Berkeley National Laboratory, One Cyclotron Road, MS/72, Berkeley, CA 94720 (United States)

    2010-04-15

    Using two levels of electron beam lithography, vapor phase deposition techniques, and FIB etching, we have fabricated an electrostatic Boersch phase plate for contrast enhancement of weak phase objects in a transmission electron microscope. The phase plate has suitable dimensions for the imaging of small biological samples without compromising the high-resolution capabilities of the microscope. A micro-structured electrode allows for phase tuning of the unscattered electron beam, which enables the recording of contrast enhanced in-focus images and in-line holograms. We have demonstrated experimentally that our phase plate improves the contrast of carbon nanotubes while maintaining high-resolution imaging performance, which is demonstrated for the case of an AlGaAs heterostructure. The development opens a new way to study interfaces between soft and hard materials.

  9. Compact design of a transmission electron microscope-scanning tunneling microscope holder with three-dimensional coarse motion

    International Nuclear Information System (INIS)

    Svensson, K.; Jompol, Y.; Olin, H.; Olsson, E.

    2003-01-01

    A scanning tunneling microscope (STM) with a compact, three-dimensional, inertial slider design is presented. Inertial sliding of the STM tip, in three dimensions, enables coarse motion and scanning using only one piezoelectric tube. Using the same electronics both for scanning and inertial sliding, step lengths of less than 5% of the piezo range were achieved. The compact design, less than 1 cm3 in volume, ensures a low mechanical noise level and enables us to fit the STM into the sample holder of a transmission electron microscope (TEM), while maintaining atomic scale resolution in both STM and TEM imaging

  10. Electron energy loss spectroscopy microanalysis and imaging in the transmission electron microscope: example of biological applications

    International Nuclear Information System (INIS)

    Diociaiuti, Marco

    2005-01-01

    This paper reports original results obtained in our laboratory over the past few years in the application of both electron energy loss spectroscopy (EELS) and electron spectroscopy imaging (ESI) to biological samples, performed in two transmission electron microscopes (TEM) equipped with high-resolution electron filters and spectrometers: a Gatan model 607 single magnetic sector double focusing EEL serial spectrometer attached to a Philips 430 TEM and a Zeiss EM902 Energy Filtering TEM. The primary interest was on the possibility offered by the combined application of these spectroscopic techniques with those offered by the TEM. In particular, the electron beam focusing available in a TEM allowed us to perform EELS and ESI on very small sample volumes, where high-resolution imaging and electron diffraction techniques can provide important structural information. I show that ESI was able to improve TEM performance, due to the reduced chromatic aberration and the possibility of avoiding the sample staining procedure. Finally, the analysis of the oscillating extended energy loss fine structure (EXELFS) beyond the ionization edges characterizing the EELS spectra allowed me, in a manner very similar to the extended X-ray absorption fine structure (EXAFS) analysis of the X-ray absorption spectra, to obtain short-range structural information for such light elements of biological interest as O or Fe. The Philips EM430 (250-300 keV) TEM was used to perform EELS microanalysis on Ca, P, O, Fe, Al and Si. The assessment of the detection limits of this method was obtained working with well-characterized samples containing Ca and P, and mimicking the actual cellular matrix. I applied EELS microanalysis to Ca detection in bone tissue during the mineralization process and to P detection in the cellular membrane of erythrocytes treated with an anti-tumoral drug, demonstrating that the cellular membrane is a drug target. I applied EELS microanalysis and selected area electron

  11. Microscopic appearance analysis of raw material used for the production of sintered UO2 by scanning electron microscope

    International Nuclear Information System (INIS)

    Liu feiming

    1992-01-01

    The paper describes the microscopic appearance of UO 2 , U 3 O 8 , ADU and AUC powders used for the production of sintered UO 2 slug of nuclear fuel component of PWR. The characteristic analysis of the microscopic appearance observed by scanning electron microscope shows that the quality and finished product rate of sintered UO 2 depend on the appearance characteristic of the active Uo 2 powder, such as grade size and its distribution, spherulitized extent, surface condition and heap model etc.. The addition of U 3 O 8 to the UO 2 powder improves significantly the quality and the finished product rate. The mechanism of this effect is discussed on the basis of the microscopic appearance characteristic for two kinds of powder

  12. Electron Source Brightness and Illumination Semi-Angle Distribution Measurement in a Transmission Electron Microscope.

    Science.gov (United States)

    Börrnert, Felix; Renner, Julian; Kaiser, Ute

    2018-05-21

    The electron source brightness is an important parameter in an electron microscope. Reliable and easy brightness measurement routes are not easily found. A determination method for the illumination semi-angle distribution in transmission electron microscopy is even less well documented. Herein, we report a simple measurement route for both entities and demonstrate it on a state-of-the-art instrument. The reduced axial brightness of the FEI X-FEG with a monochromator was determined to be larger than 108 A/(m2 sr V).

  13. High-resolution, high-throughput imaging with a multibeam scanning electron microscope.

    Science.gov (United States)

    Eberle, A L; Mikula, S; Schalek, R; Lichtman, J; Knothe Tate, M L; Zeidler, D

    2015-08-01

    Electron-electron interactions and detector bandwidth limit the maximal imaging speed of single-beam scanning electron microscopes. We use multiple electron beams in a single column and detect secondary electrons in parallel to increase the imaging speed by close to two orders of magnitude and demonstrate imaging for a variety of samples ranging from biological brain tissue to semiconductor wafers. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  14. Wide-range tunable magnetic lens for tabletop electron microscope

    International Nuclear Information System (INIS)

    Chang, Wei-Yu; Chen, Fu-Rong

    2016-01-01

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  15. Contact detection for nanomanipulation in a scanning electron microscope.

    Science.gov (United States)

    Ru, Changhai; To, Steve

    2012-07-01

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. AIMgSil Alloy Characterization Using Transmission Electron Microscope (TEM)

    International Nuclear Information System (INIS)

    Masrukan; Elman, P.

    1996-01-01

    The aging alloy of AIMgSil containing Mg 2 Si of 1.29 % has been done with the following steps: e.q (a) part of the specimen was heated at 400 o C during 3 hours, and (b) the other part was done with solution treatment at 550 o C followed by quenching. After quenching a part of the specimen was aged at room temperature and other specimen was aged at 160 o C during 16 hours. After the specimen had been heated, then it was shaped into thin foil to be examined by Transmission Electron Microscope. The result showed that the heating at temperature of 400 o C during 3 hours created a second phase (i.e.Mg 2 Si) was like stick shape with the hexagonal structure at [0111] orientation and matrix [001], and the hardness was 31 HB. The aging of specimen at room temperature gave result a GP zone which was like the needles shape in the dislocation area of the face center cubic structure at [111] orientation and [111] matrix. The hardness obtained was 64 HB. In the other hand the aging process at temperature of 160 o C within 16 hours have resulted the precipitate which was greater than that of the former needle shaped as the face center cubic structure without dislocation at matrix with [111] orientation and [114] matrix. The hardness at this condition was 94 HB

  17. Contact detection for nanomanipulation in a scanning electron microscope

    International Nuclear Information System (INIS)

    Ru, Changhai; To, Steve

    2012-01-01

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. -- Highlights: ► We presents a simple method for obtaining the depth information in SEM-based nanomanipulation. ► Detecting contact between an end-effector and a target surface using SEM as a vision sensor. ► Additional touch/force sensors or specialized hardware need not be added. ► Achieved high repeatability and accuracy. ► Complete automatic contact detection within typically 60 s.

  18. Wide-range tunable magnetic lens for tabletop electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Yu; Chen, Fu-Rong, E-mail: fchen1@me.com

    2016-12-15

    A tabletop scanning electron microscope (SEM) utilizes permanent magnets as condenser lenses to minimize its size, but this sacrifices the tunability of condenser lenses such that a tabletop system can only be operated with a fixed accelerating voltage. In contrast, the traditional condenser lens utilizes an electromagnetic coil to adjust the optical properties, but the size of the electromagnetic lens is inevitably larger. Here, we propose a tunable condenser lens for a tabletop SEM that uses a combination of permanent magnets and electromagnetic coils. The overall dimensions of the newly designed lens are the same as the original permanent magnet lens, but the new lens allows the tabletop SEM to be operated at different accelerating voltages between 1 kV and 15 kV. - Highlights: • A compact condenser lens combines both permanent magnet and coils. • A tunable lens is designed to keep the same focal point for voltage 1 to 15 kV. • A miniature tunable lens which can directly fit into tabletop SEM.

  19. Contact detection for nanomanipulation in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ru, Changhai, E-mail: rchhai@gmail.com [Automation College, Harbin Engineering University, Harbin 150001 (China); Robotics and Microsystems Center, Soochow University, Jiangsu 215021 (China); To, Steve, E-mail: Steve.to@utoronto.ca [Department of Mechanical and Industry Engineering, University of Toronto, Ontario, Canada M5S3G8 (Canada)

    2012-07-15

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000 Multiplication-Sign magnification while inducing little end-effector damage. -- Highlights: Black-Right-Pointing-Pointer We presents a simple method for obtaining the depth information in SEM-based nanomanipulation. Black-Right-Pointing-Pointer Detecting contact between an end-effector and a target surface using SEM as a vision sensor. Black-Right-Pointing-Pointer Additional touch/force sensors or specialized hardware need not be added. Black-Right-Pointing-Pointer Achieved high repeatability and accuracy. Black-Right-Pointing-Pointer Complete automatic contact detection within typically 60 s.

  20. Scanning electron microscope cathodoluminescence imaging of subgrain boundaries, twins and planar deformation features in quartz

    Science.gov (United States)

    Hamers, M. F.; Pennock, G. M.; Drury, M. R.

    2017-04-01

    The study of deformation features has been of great importance to determine deformation mechanisms in quartz. Relevant microstructures in both growth and deformation processes include dislocations, subgrains, subgrain boundaries, Brazil and Dauphiné twins and planar deformation features (PDFs). Dislocations and twin boundaries are most commonly imaged using a transmission electron microscope (TEM), because these cannot directly be observed using light microscopy, in contrast to PDFs. Here, we show that red-filtered cathodoluminescence imaging in a scanning electron microscope (SEM) is a useful method to visualise subgrain boundaries, Brazil and Dauphiné twin boundaries. Because standard petrographic thin sections can be studied in the SEM, the observed structures can be directly and easily correlated to light microscopy studies. In contrast to TEM preparation methods, SEM techniques are non-destructive to the area of interest on a petrographic thin section.

  1. X-ray analysis of a single aerosol particle with combination of scanning electron microscope and synchrotron radiation X-ray microscope

    International Nuclear Information System (INIS)

    Toyoda, Masatoshi; Kaibuchi, Kazuki; Nagasono, Mitsuru; Terada, Yasuko; Tanabe, Teruo; Hayakawa, Shinjiro; Kawai, Jun

    2004-01-01

    We developed a microscope by a combination of synchrotron radiation X-ray fluorescence (SR-XRF) microscope and scanning electron microscope (SEM) with an energy dispersive X-ray spectrometer (EDX). SR-XRF is appropriate to detect trace and micro amount of elements and sensitive to heavy elements in an analyte but it cannot observe the real time image. SEM-EDX can observe the secondary electron image of a single particle in real time and is appropriate to detect lighter elements. This combination microscope can ensure the identification of the XRF spectrum to the SEM image without transferring the sample. For aerosol analysis, it is important to analyze each particle. The present method makes feasible to analyze not only the average elemental composition as the total particles but also elemental composition of each particle, which is dependent on the particle shape and size. The microscope was applied to an individual aerosol particle study. The X-ray spectra were different among the particles, but also different between SR-XRF and SEM-EDX for the same particle, due to the difference in fluorescence yields between X-ray excitation and electron excitation

  2. Characterization of Li-rich layered oxides by using transmission electron microscope

    Directory of Open Access Journals (Sweden)

    Hu Zhao

    2017-07-01

    Full Text Available Lithium-rich layered oxides (LrLOs deliver extremely high specific capacities and are considered to be promising candidates for electric vehicle and smart grid applications. However, the application of LrLOs needs further understanding of the structural complexity and dynamic evolution of monoclinic and rhombohedral phases, in order to overcome the issues including voltage decay, poor rate capability, initial irreversible capacity loss and etc. The development of aberration correction for the transmission electron microscope and concurrent progress in electron spectroscopy, have fueled rapid progress in the understanding of the mechanism of such issues. New techniques based on the transmission electron microscope are first surveyed, and the applications of these techniques for the study of the structure, migration of transition metal, and the activation of oxygen of LrLOs are then explored in detail, with a particular focus on the mechanism of voltage decay. Keywords: Lithium-ion battery, Transmission electron microscope, Lithium-rich layered oxide, Cathode material

  3. A Transmission Electron Microscope Investigation of Space Weathering Effects in Hayabusa Samples

    Science.gov (United States)

    Keller, Lindsay P.; Berger, Eve L.

    2014-01-01

    The Hayabusa mission to asteroid 25143 Itokawa successfully returned the first direct samples of the regolith from the surface of an asteroid. The Hayabusa samples thus present a special opportunity to directly investigate the evolution of asteroidal surfaces, from the development of the regolith to the study of the more complex effects of space weathering. Here we describe the mineralogy, microstructure and composition of three Hayabusa mission particles using transmission electron microscope (TEM) techniques

  4. Elementary and advanced Lie algebraic methods with applications to accelerator design, electron microscopes, and light optics

    International Nuclear Information System (INIS)

    Dragt, A.J.

    1987-01-01

    A review is given of elementary Lie algebraic methods for treating Hamiltonian systems. This review is followed by a brief exposition of advanced Lie algebraic methods including resonance bases and conjugacy theorems. Finally, applications are made to the design of third-order achromats for use in accelerators, to the design of subangstroem resolution electron microscopes, and to the classification and study of high order aberrations in light optics. (orig.)

  5. Histochemical, light and electron microscopic study of polonium-210 induced peripheral tumours in hamster lungs -evidence implicating the Clara Cell as the cell of origin

    International Nuclear Information System (INIS)

    Kennedy, A.R.; McGandy, R.B.; Little, J.B.

    1977-01-01

    Peripheral lung tumors induced in Syrian golden hamsters by intratracheally administered polonium-210 ( 210 Po) are similar to the peripheral lung tumours induced in many species by a variety of carcinogens. In addition, they show many of the histopathological features observed in human bronchiolar-alveolar carcinomas. Serial sacrifice studies of hamsters exposed to multiple instillations of 210 Po have been carried our to identify the cell of origin of these tumors. By means of thin, plastic (glycol methacrylate) sections, electron microscopy, and histochemistry, it is concluded that the bronchiolar Clara cell is the probable cell of origin, and that this view is generally compatible with many of the reported cytological characteristics of the human tumor. (author)

  6. Electron microscope study of vacancy clusters produced by quenching in magnesium; Etude par microscopie electronique des amas de lacunes crees par trempe dans le magnesium

    Energy Technology Data Exchange (ETDEWEB)

    Levy, V; Espinasse, J; Mairy, C; Hillairet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Vacancy clustering in quenched magnesium has been studied by transmission electron microscopy. The nature of the vacancy loops observed, seems to depend essentially on the impurity content of the metal; this effect can be attributed to a variation of the stacking fault energy of magnesium due to impurities. (authors) [French] On a etudie par microscopie electronique en transmission les defauts crees par trempe dans le magnesium. Un effet considerable des impuretes du metal sur la nature des boucles obtenues par condensation de lacunes a ete mis en evidence; cet effet semble s'expliquer de facon satisfaisante par un abaissement de l'energie de faute d'empilement du magnesium du aux impuretes. (auteur)

  7. Light and electron microscopic study of the eyelids, conjunctiva-associated lymphoid tissue and lacrimal gland in Bilgorajska Goose (Anser anser).

    Science.gov (United States)

    Klećkowska-Nawrot, Joanna; Nowaczyk, Renata; Goździewska-Harłajczuk, Karolina; Barszcz, Karolina; Kowalczyk, Artur; Łukaszewicz, Ewa

    2016-01-01

    Normal structure of the accessory organs of the eye is essential for normal eye physiology. Among the most important accessory organs of the eye are the eyelids, the conjunctiva-associated lymphoid tissue (CALT) and the lacrimal gland (LG). The aim of this study was to demonstrate the histological structure of the eyelids and LG by histochemical and ultrastructural analysis. The study was performed on 13 adult female Bilgorajska geese. Eyelid samples were stained with the Alcian blue (AB pH 2.5) and periodic acid-Schiff (PAS) methods. Staining methods used for LG were AB pH 2.5, aldehyde fuchsin (AF), PAS and Hale's dialysed iron (HDI). Within the connective tissue of the eyelids, well-developed, diffuse, CALT follicles were observed, mostly under the conjunctival epithelium. Numerous lymphocytes were present within loose connective tissue. Staining of the eyelids with the PAS method demonstrated the presence of goblet cells of a mucous nature, and AB pH 2.5 staining indicated the presence of sulfated acid mucopolysaccharides. PAS staining of LG revealed the presence of secretory cells containing weakly PAS-positive granules. All epithelial cells of the corpus glandulae and the duct systems reacted positively to AB pH 2.5. HDI staining detected the presence of carboxylated acid mucopolysaccharides. Transmission electron microscopy investigations revealed two types of secretory epithelial cells in LG. Both types of LG cells contained drop-like secretory vesicles of different sizes with low or high electron density in cytoplasm, as well as small and large lipid vacuoles, and numerous small primary lysosomes.

  8. The Design and Construction of a Simple Transmission Electron Microscope for Educational Purposes.

    Science.gov (United States)

    Hearsey, Paul K.

    This document presents a model for a simple transmission electron microscope for educational purposes. This microscope could demonstrate thermonic emission, particle acceleration, electron deflection, and flourescence. It is designed to be used in high school science courses, particularly physics, taking into account the size, weight, complexity…

  9. Remote control scanning electron microscope with Web operation

    International Nuclear Information System (INIS)

    Yamada, A.; Hirahara, O.; Date, M.; Lozbin, V.; Tsuchida, T.; Sugano, N.

    2002-01-01

    Full text: Recently, SEM (Scanning Electron Microscope) and the other observation instruments are coming to use a LAN (Local Area Network) to save the image in the database. We developed a remote control system in which SEM image and Control interface is indicated on the WEB Browser. In this system, SEM can be controlled by an external (client) PC installed in a general WEB Browser (Internet Explorer). Accordingly, operation interface can be indicated on the WEB browser. A JSM-6700F is connected to a LAN, and so a client PC can control the microscope. The JSM-6700F has two lines to the LAN for image transfer and communication with the SEM control. In order to transfer the image, the image size squeezes from 1280 x 1024-pixels (SEM image size) to 640x480-pixels for quick transfer. The image signal (640 x 480-pixels) is connected to the video server only, and then the image transfers to the client PC via LAN. The SEM control communicates with client PC for external command. On the other hand, the SEM control interface and the image are indicated on WEB Browser (Internet explorer). The SEM control interface is composed of the SEM image area and the SEM control part. The SEM image indicates the 640x480-pixels live image. This live image is being used as a high resolution live image transfer in the image transfer technology which a network is used for at present. If it is LAN beyond 10 base, this indication of an image can be transferred fully. When it is connected in the small line of the capacity, the refresh speed of the image becomes slow because of image data doesn't finish transferring it. In such a case, image size can be changed smaller by the LAN conditions. When a high quality image is necessary, the image of 1280 x 1024-pixels is saved on a SEM (server) side by choosing the image save button. At the same time, the file kept in SEM (server) is transferred to the client PC automatically, so that we can display a high quality image on the client PC side. The

  10. Neural Network for Nanoscience Scanning Electron Microscope Image Recognition.

    Science.gov (United States)

    Modarres, Mohammad Hadi; Aversa, Rossella; Cozzini, Stefano; Ciancio, Regina; Leto, Angelo; Brandino, Giuseppe Piero

    2017-10-16

    In this paper we applied transfer learning techniques for image recognition, automatic categorization, and labeling of nanoscience images obtained by scanning electron microscope (SEM). Roughly 20,000 SEM images were manually classified into 10 categories to form a labeled training set, which can be used as a reference set for future applications of deep learning enhanced algorithms in the nanoscience domain. The categories chosen spanned the range of 0-Dimensional (0D) objects such as particles, 1D nanowires and fibres, 2D films and coated surfaces, and 3D patterned surfaces such as pillars. The training set was used to retrain on the SEM dataset and to compare many convolutional neural network models (Inception-v3, Inception-v4, ResNet). We obtained compatible results by performing a feature extraction of the different models on the same dataset. We performed additional analysis of the classifier on a second test set to further investigate the results both on particular cases and from a statistical point of view. Our algorithm was able to successfully classify around 90% of a test dataset consisting of SEM images, while reduced accuracy was found in the case of images at the boundary between two categories or containing elements of multiple categories. In these cases, the image classification did not identify a predominant category with a high score. We used the statistical outcomes from testing to deploy a semi-automatic workflow able to classify and label images generated by the SEM. Finally, a separate training was performed to determine the volume fraction of coherently aligned nanowires in SEM images. The results were compared with what was obtained using the Local Gradient Orientation method. This example demonstrates the versatility and the potential of transfer learning to address specific tasks of interest in nanoscience applications.

  11. Identification of dorsal root synaptic terminals on monkey ventral horn cells by electron microscopic autoradiography

    International Nuclear Information System (INIS)

    Ralston, H.J.; Ralston, D.D.

    1979-01-01

    The projection of dorsal root fibres to the motor nucleus of the macaque monkey spinal cord has been examined utilizing light and electron microscopic autoradiography. Light microscopy demonstrates a very sparse labelling of primary afferent fibres in the ventral horn. Silver grains overlying radioactive sources are frequently clustered into small groups, often adjacent to dendritic profiles. Under the electron microscope, myelinated axons and a few large synaptic profiles containing rounded synaptic vesicles were overlain by numerous silver grains. These labelled profiles made synaptic contact with dendrites 1 - 3 micrometers in diameter. The labelled profiles did not contact cell bodies or large proximal dendrites of ventral horn neutrons. Frequently, small synaptic profiles containing flattened vesicles were presynaptic to the large labelled terminals and it is suggested that these axoaxonal synapses may mediate presynaptic inhibition of the primary afferent fibres. The relationship of the present findings to previously published physiological and anatomical studies is discussed. (author)

  12. Digital acquisition and processing of electron micrographs using a scanning transmission electron microscope

    International Nuclear Information System (INIS)

    Engel, A.; Christen, F.; Michel, B.

    1981-01-01

    A digital acquisition system that collects multichannel information from a scanning transmission electron microscope (STEM) and its application are described. The hardware comprises (i) single electron counting detectors, (ii) a digital scan generator, (iii) a digital multi-channel on-line processor, (iv) an interface to a minicomputer, and (v) a display system. Experimental results characterizing these components are presented, and their performance is discussed. The software includes assembler coded programs for dynamic file maintenance and fast acquisition of image data, a display driver, and FORTRAN coded application programs. The usefulness of digitized STEM is illustrated by a variety of biological applications. (orig.)

  13. Influence of cathode geometry on electron dynamics in an ultrafast electron microscope

    Directory of Open Access Journals (Sweden)

    Shaozheng Ji

    2017-09-01

    Full Text Available Efforts to understand matter at ever-increasing spatial and temporal resolutions have led to the development of instruments such as the ultrafast transmission electron microscope (UEM that can capture transient processes with combined nanometer and picosecond resolutions. However, analysis by UEM is often associated with extended acquisition times, mainly due to the limitations of the electron gun. Improvements are hampered by tradeoffs in realizing combinations of the conflicting objectives for source size, emittance, and energy and temporal dispersion. Fundamentally, the performance of the gun is a function of the cathode material, the gun and cathode geometry, and the local fields. Especially shank emission from a truncated tip cathode results in severe broadening effects and therefore such electrons must be filtered by applying a Wehnelt bias. Here we study the influence of the cathode geometry and the Wehnelt bias on the performance of a photoelectron gun in a thermionic configuration. We combine experimental analysis with finite element simulations tracing the paths of individual photoelectrons in the relevant 3D geometry. Specifically, we compare the performance of guard ring cathodes with no shank emission to conventional truncated tip geometries. We find that a guard ring cathode allows operation at minimum Wehnelt bias and improve the temporal resolution under realistic operation conditions in an UEM. At low bias, the Wehnelt exhibits stronger focus for guard ring than truncated tip cathodes. The increase in temporal spread with bias is mainly a result from a decrease in the accelerating field near the cathode surface. Furthermore, simulations reveal that the temporal dispersion is also influenced by the intrinsic angular distribution in the photoemission process and the initial energy spread. However, a smaller emission spot on the cathode is not a dominant driver for enhancing time resolution. Space charge induced temporal broadening

  14. Influence of cathode geometry on electron dynamics in an ultrafast electron microscope.

    Science.gov (United States)

    Ji, Shaozheng; Piazza, Luca; Cao, Gaolong; Park, Sang Tae; Reed, Bryan W; Masiel, Daniel J; Weissenrieder, Jonas

    2017-09-01

    Efforts to understand matter at ever-increasing spatial and temporal resolutions have led to the development of instruments such as the ultrafast transmission electron microscope (UEM) that can capture transient processes with combined nanometer and picosecond resolutions. However, analysis by UEM is often associated with extended acquisition times, mainly due to the limitations of the electron gun. Improvements are hampered by tradeoffs in realizing combinations of the conflicting objectives for source size, emittance, and energy and temporal dispersion. Fundamentally, the performance of the gun is a function of the cathode material, the gun and cathode geometry, and the local fields. Especially shank emission from a truncated tip cathode results in severe broadening effects and therefore such electrons must be filtered by applying a Wehnelt bias. Here we study the influence of the cathode geometry and the Wehnelt bias on the performance of a photoelectron gun in a thermionic configuration. We combine experimental analysis with finite element simulations tracing the paths of individual photoelectrons in the relevant 3D geometry. Specifically, we compare the performance of guard ring cathodes with no shank emission to conventional truncated tip geometries. We find that a guard ring cathode allows operation at minimum Wehnelt bias and improve the temporal resolution under realistic operation conditions in an UEM. At low bias, the Wehnelt exhibits stronger focus for guard ring than truncated tip cathodes. The increase in temporal spread with bias is mainly a result from a decrease in the accelerating field near the cathode surface. Furthermore, simulations reveal that the temporal dispersion is also influenced by the intrinsic angular distribution in the photoemission process and the initial energy spread. However, a smaller emission spot on the cathode is not a dominant driver for enhancing time resolution. Space charge induced temporal broadening shows a close to

  15. Distribution patterns and morphology of sensilla on the antennae of Plutella xylostella (L.)-A scanning and transmission electron microscopic study.

    Science.gov (United States)

    Yan, Xi-Zhong; Deng, Cai-Ping; Xie, Jiao-Xin; Wu, Lan-Jun; Sun, Xue-Jun; Hao, Chi

    2017-12-01

    The antennal morphology, types of antennal sensilla, fine structures and distributions of the sensilla in Plutella xylostella L. (Lepidoptera: Plutellidae) were studied by scanning (SEM) and transmission (TEM) electron microscopy. The antenna, scape, pedicel and flagellum were all longer in males than in females. A total of seventeen types of sensilla were identified on the antennae: trichodea (two subtypes), basiconica, coeloconica (three subtypes), Böhm's bristles (two subtypes), styloconica (two subtypes), squamiformia, auricillica, furcatea (three subtypes), cupuliform organs and terminal sensory pegs. Their numbers and distributions were studied in both male and female, and we found some of the sensilla exhibited various degrees of sexual dimorphisms. Sensilla trichodea were the most abundant of all sensillum types whereas terminal peg was present only once per antenna. Sensilla trichodea in males were bigger (subtype I) and more abundant than in females, however, sensilla basiconica and squamiformia were significantly smaller and less abundant in males than in females. Sensilla styloconica II was only found in females. Seven common sensillum types were studied with TEM to reveal its fine internal structure providing morphological evidences of their sensory functions. Sensilla trichodea I, basiconica and coeloconica III have porous walls suggesting olfactory functions. Combined with the sexual dimorphism, sensilla trichodea male P. xylostella might be involved in detecting sexual pheromones and sensilla basiconica of female might respond to host plant volatiles. Whereas sensilla coeloconica (subtype I and II) and Böhm's bristles have nonporous walls suggesting non-olfactory functions. The study presented a thorough inventory of sensilla on the antennae and laid a solid foundation for future functional studies of these sensilla in this important economical pest. Copyright © 2017. Published by Elsevier Ltd.

  16. Enhanced thermal stability of a polymer solar cell blend induced by electron beam irradiation in the transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Bäcke, Olof, E-mail: obacke@chalmers.se [Department of Applied Physics, Chalmers University of Technology, 41296 Göteborg (Sweden); Lindqvist, Camilla; Diaz de Zerio Mendaza, Amaia [Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 41296 Göteborg (Sweden); Gustafsson, Stefan [Department of Applied Physics, Chalmers University of Technology, 41296 Göteborg (Sweden); Wang, Ergang; Andersson, Mats R.; Müller, Christian [Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 41296 Göteborg (Sweden); Kristiansen, Per Magnus [Institute of Polymer Nanotechnology (INKA), FHNW University of Applied Science and Arts Northwestern Switzerland, 5210 Windisch (Switzerland); Laboratory for Micro- and Nanotechnology, Paul Scherrer Institute, 5232 Villigen (Switzerland); Olsson, Eva, E-mail: eva.olsson@chalmers.se [Department of Applied Physics, Chalmers University of Technology, 41296 Göteborg (Sweden)

    2017-05-15

    We show by in situ microscopy that the effects of electron beam irradiation during transmission electron microscopy can be used to lock microstructural features and enhance the structural thermal stability of a nanostructured polymer:fullerene blend. Polymer:fullerene bulk-heterojunction thin films show great promise for use as active layers in organic solar cells but their low thermal stability is a hindrance. Lack of thermal stability complicates manufacturing and influences the lifetime of devices. To investigate how electron irradiation affects the thermal stability of polymer:fullerene films, a model bulk-heterojunction film based on a thiophene-quinoxaline copolymer and a fullerene derivative was heat-treated in-situ in a transmission electron microscope. In areas of the film that exposed to the electron beam the nanostructure of the film remained stable, while the nanostructure in areas not exposed to the electron beam underwent large phase separation and nucleation of fullerene crystals. UV–vis spectroscopy shows that the polymer:fullerene films are stable for electron doses up to 2000 kGy. - Highlights: • Thermal stability of a polymer: fullerne blend is increased using electron irradiation. • Using in-situ transmission electron microscopy the nanostructure is studied. • Electron irradiation stops phase separation between the polymer and fullerene. • Electron irradiation quenches the formation and nucleation of fullerene crystals.

  17. In-Situ Microprobe Observations of Dispersed Oil with Low-Temperature Low-Vacuum Scanning Electron Microscope

    International Nuclear Information System (INIS)

    Mohsen, H.T.

    2010-01-01

    A low cost cryostat stage from high heat capacity material is designed and constructed, in attempt to apply size distribution techniques for examination of oil dispersions. Different materials were tested according to their heat capacity to keep the liquid under investigation in frozen state as long as possible during the introduction of the cryostat stage to the low-vacuum scanning electron microscope. Different concentrations of non ionic surfactant were added to artificially contaminated with 10000 ppm Balayeam base oil in 3.5 % saline water, where oil and dispersing liquid have been added and shacked well to be investigated under the microscope as fine frozen droplets. The efficiency of dispersion was examined using low temperature low-vacuum scanning electron microscope. The shape and size distributions of freeze oil droplets were studied by digital imaging processing technique in conjunction with scanning electron microscope counting method. Also elemental concentration of oil droplets was analyzed.

  18. Differences in Endothelial Injury After Balloon Angioplasty, Insertion of Balloon-Expanded Stents or Release of Self-Expanding Stents: An Electron Microscopic Experimental Study

    International Nuclear Information System (INIS)

    Harnek, Jan; Zoucas, Evita; Carlemalm, Erik; Cwikiel, Wojciech

    1999-01-01

    Purpose: To evaluate which of six different commonly available stents inserted into an artery without percutaneous transluminal angioplasty (PTA) causes the least endothelial damage. To compare the degree of endothelial injury after insertion of such a stent with injury caused by PTA. Methods: Twelve healthy pigs were used in the experiments. In the first part of the study six different types of stents were inserted into the common iliac arteries. In the second part of the study self-expanding stents with large spaces between the wires were used. PTA was performed in the contralateral iliac artery. The pigs were killed immediately after the procedure and resected specimens examined after fixation, using scanning electron microscopy. Results: All procedures but two were accomplished successfully. More endothelium was preserved after insertion of self-expanding stents with large spaces between the wires, compared with stents with small spaces and balloon-expanded stents. After insertion of self-expanding stents with large spaces, 50.1% ± 16.4% of the endothelium remained intact, compared with only 5.6% ± 7.7% after PTA. The difference was statistically significant (p < 0.001). Conclusion: Self-expanding stents with large spaces between the wires, inserted without PTA, cause less damage to the endothelium than other stents and significantly less damage than PTA

  19. Spin polarized electron source technology transferred from HE accelerators to electron microscopes

    International Nuclear Information System (INIS)

    Nakanishi, Tsutomu

    2009-01-01

    For many years, we have developed a technology of spin-polarized-electron-source (PES) for a future linear collider project (ILC). Various new techniques for achieving high polarization, high quantum efficiency, high current density, sub-nanosecond multi-bunch generation etc. were developed. Two fundamental technologies; reduction of dark current and preparation of extremely high vacuum environment to protect the Negative Electron Affinity (NEA) surface have been also developed. Using these PES technologies and a new transmission type photocathode, we recently succeeded in producing the high brightness and high polarization electron beam for the low energy electron microscope (LEEM). Our Spin-LEEM system enables the world-first dynamic observation of surface magnetic domain formed by evaporation on the metal substrate with ∼ 20 nm space resolutions. (author)

  20. Simulation of electron displacement damage in a high voltage electron microscope

    International Nuclear Information System (INIS)

    Ono, Susumu; Kanaya, Koichi

    1979-01-01

    By applying the fundamental theory of the neutron cooling to the conservation law of energy and momentum, the threshold energies of incident electrons for displacing atoms are calculated and illustrated periodically for the atomic number. And the observable damage due to the secondary action of displaced atoms in the practical use of a high voltage electron microscope is described for several materials and accelerating voltages. The trajectories of incident electrons and displaced atoms in several materials are simulated by a Monte-Carlo method, using rigorous formulas of electron scattering events, i.e. elastic and inelastic scattering cross-sections, ionization loss and plasmon excitation. The simulation results are substantially agreement with experiments. (author)

  1. On the Progress of Scanning Transmission Electron Microscopy (STEM) Imaging in a Scanning Electron Microscope.

    Science.gov (United States)

    Sun, Cheng; Müller, Erich; Meffert, Matthias; Gerthsen, Dagmar

    2018-04-01

    Transmission electron microscopy (TEM) with low-energy electrons has been recognized as an important addition to the family of electron microscopies as it may avoid knock-on damage and increase the contrast of weakly scattering objects. Scanning electron microscopes (SEMs) are well suited for low-energy electron microscopy with maximum electron energies of 30 keV, but they are mainly used for topography imaging of bulk samples. Implementation of a scanning transmission electron microscopy (STEM) detector and a charge-coupled-device camera for the acquisition of on-axis transmission electron diffraction (TED) patterns, in combination with recent resolution improvements, make SEMs highly interesting for structure analysis of some electron-transparent specimens which are traditionally investigated by TEM. A new aspect is correlative SEM, STEM, and TED imaging from the same specimen region in a SEM which leads to a wealth of information. Simultaneous image acquisition gives information on surface topography, inner structure including crystal defects and qualitative material contrast. Lattice-fringe resolution is obtained in bright-field STEM imaging. The benefits of correlative SEM/STEM/TED imaging in a SEM are exemplified by structure analyses from representative sample classes such as nanoparticulates and bulk materials.

  2. Morphological description of Cosmocerca sp. (Nematoda: Cosmocerdidae) from the Mascarene grass frog Ptychadena cf. mascareniensis (Amphibia: Ptychadenidae). A light and scanning electron microscopic studies.

    Science.gov (United States)

    Abdel-Gaber, Rewaida; Abdel-Ghaffar, Fathy; Kamel, Reem; Maher, Sherein; El Deeb, Nashwa; Al Quraishy, Saleh; Mehlhorn, Heinz

    2017-06-01

    The Mascarene grass frog Ptychadena cf. mascareniensis is a species of frog with a vast area of distribution in Africa. A total of 300 frog specimens were collected from different localities at El-Giza province, Egypt; then dissected and examined for the presence of parasitic infection. Only eighty six (28.66%) specimens were found to be naturally infected with nematode parasite. Seasonally, the prevalence of infection was reached its maximum value of 74.66% during summer and minimum values of 26.66% (20/75), 13.33% (10/75) during spring and autumn, respectively; while no records were observed during winter season. The morphology of the recovered parasite was studied by using light and scanning electron microscopy. The adult worm characterized by anterior extremity with small mouth opening being surrounded by three lips provided with four sub-median cephalic papillae and one pair of lateral amphids. Body measurements showed that male worms were smaller than females measuring 1.22-2.43 (2.21 ± 0.1) mm in length and 0.21-0.34 (0.29 ± 0.01) mm in width. Females measured 1.9-3.7 (2.8 ± 0.1) mm in length and 0.24-0.42 (0.38 ± 0.01) mm in width. Comparing the present parasite with other species of the same genus described previously, several similarities were observed. However, peculiar new characteristics such as the arrangement of plectanes and somatic papillae, the presence of gubernaculum, the position of nerve ring, excretory pore, and vulval opening make it reasonable belongs to the family Cosmocercidae and identified as Cosmocerca sp. In addition, the present study was the first report for occurrence of cosmocercid species from the Mascarene grass frog in Egypt.

  3. Microscopic Superconductivity and Room Temperature Electronics of High-Tc Cuprates

    International Nuclear Information System (INIS)

    Liu Fusui; Chen Wanfang

    2008-01-01

    This paper points out that the Landau criterion for macroscopic superfluidity of He II is only a criterion for microscopic superfluidity of 4 He, extends the Landau criterion to microscopic superconductivity in fermions (electron and hole) system and system with Cooper pairs without long-range phase coherence. This paper gives another three non-superconductive systems that are of microscopic superconductivity. This paper demonstrates that one application of microscopic superconductivity is to establish room temperature electronics of the high-T c cuprates

  4. Atomic-resolution studies of In{sub 2}O{sub 3}-ZnO compounds on aberration-corrected electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Wentao

    2009-10-23

    In this work, the characteristic inversion domain microstructures of In{sub 2}O{sub 3}(ZnO){sub m} (m=30) compounds were investigated by TEM methods. At bright-atom contrast condition, atomically resolved HR-TEM images of In{sub 2}O{sub 3}(ZnO){sub 30} were successfully acquired in [1 anti 100] zone axis of ZnO, with projected metal columns of {proportional_to}1.6 A well resolved. From contrast maxima in the TEM images, local lattice distortions at the pyramidal inversion domain boundaries were observed for the first time. Lattice displacements and the strain field in two-dimensions were visualized and measured using the 'DALI' algorithm. Atomically resolved single shot and focal series images of In{sub 2}O{sub 3}(ZnO){sub 30} were achieved in both zone axes of ZnO, [1 anti 100] and [2 anti 1 anti 10], respectively. The electron waves at the exit-plane were successfully reconstructed using the software package 'TrueImage'. Finally, a three dimensional atomic structure model for the pyramidal IDB was proposed, with an In distribution of 10%, 20%, 40%, 20% and 10% of In contents over 5 atom columns along basal planes, respectively. Through a detailed structural study of In{sub 2}O{sub 3}(ZnO){sub m} compounds by using phase-contrast and Z-contrast imaging at atomic resolution, In{sup 3+} atoms are determined with trigonal bi-pyramidal co-ordination and are distributed at the pyramidal IDBs. (orig.)

  5. Apparatus and methods for controlling electron microscope stages

    Science.gov (United States)

    Duden, Thomas

    2015-08-11

    Methods and apparatus for generating an image of a specimen with a microscope (e.g., TEM) are disclosed. In one aspect, the microscope may generally include a beam generator, a stage, a detector, and an image generator. A plurality of crystal parameters, which describe a plurality of properties of a crystal sample, are received. In a display associated with the microscope, an interactive control sphere based at least in part on the received crystal parameters and that is rotatable by a user to different sphere orientations is presented. The sphere includes a plurality of stage coordinates that correspond to a plurality of positions of the stage and a plurality of crystallographic pole coordinates that correspond to a plurality of polar orientations of the crystal sample. Movement of the sphere causes movement of the stage, wherein the stage coordinates move in conjunction with the crystallographic coordinates represented by pole positions so as to show a relationship between stage positions and the pole positions.

  6. Nanosecond time-resolved investigations using the in situ of dynamic transmission electron microscope (DTEM)

    International Nuclear Information System (INIS)

    LaGrange, Thomas; Campbell, Geoffrey H.; Reed, B.W.; Taheri, Mitra; Pesavento, J. Bradley; Kim, Judy S.; Browning, Nigel D.

    2008-01-01

    Most biological processes, chemical reactions and materials dynamics occur at rates much faster than can be captured with standard video rate acquisition methods in transmission electron microscopes (TEM). Thus, there is a need to increase the temporal resolution in order to capture and understand salient features of these rapid materials processes. This paper details the development of a high-time resolution dynamic transmission electron microscope (DTEM) that captures dynamics in materials with nanosecond time resolution. The current DTEM performance, having a spatial resolution <10 nm for single-shot imaging using 15 ns electron pulses, will be discussed in the context of experimental investigations in solid state reactions of NiAl reactive multilayer films, the study of martensitic transformations in nanocrystalline Ti and the catalytic growth of Si nanowires. In addition, this paper will address the technical issues involved with high current, electron pulse operation and the near-term improvements to the electron optics, which will greatly improve the signal and spatial resolutions, and to the laser system, which will allow tailored specimen and photocathode drive conditions

  7. Nanosecond time-resolved investigations using the in situ of dynamic transmission electron microscope (DTEM)

    Energy Technology Data Exchange (ETDEWEB)

    LaGrange, Thomas [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States)], E-mail: lagrange@llnl.gov; Campbell, Geoffrey H.; Reed, B.W.; Taheri, Mitra; Pesavento, J. Bradley [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Kim, Judy S.; Browning, Nigel D. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, CA 94550 (United States); Department of Chemical Engineering and Materials Science, University of California, One Shields Avenue, Davis, CA 95616 (United States)

    2008-10-15

    Most biological processes, chemical reactions and materials dynamics occur at rates much faster than can be captured with standard video rate acquisition methods in transmission electron microscopes (TEM). Thus, there is a need to increase the temporal resolution in order to capture and understand salient features of these rapid materials processes. This paper details the development of a high-time resolution dynamic transmission electron microscope (DTEM) that captures dynamics in materials with nanosecond time resolution. The current DTEM performance, having a spatial resolution <10 nm for single-shot imaging using 15 ns electron pulses, will be discussed in the context of experimental investigations in solid state reactions of NiAl reactive multilayer films, the study of martensitic transformations in nanocrystalline Ti and the catalytic growth of Si nanowires. In addition, this paper will address the technical issues involved with high current, electron pulse operation and the near-term improvements to the electron optics, which will greatly improve the signal and spatial resolutions, and to the laser system, which will allow tailored specimen and photocathode drive conditions.

  8. Solid-state nanopores of controlled geometry fabricated in a transmission electron microscope

    Science.gov (United States)

    Qian, Hui; Egerton, Ray F.

    2017-11-01

    Energy-filtered transmission electron microscopy and electron tomography were applied to in situ studies of the formation, shape, and diameter of nanopores formed in a silicon nitride membrane in a transmission electron microscope. The nanopore geometry was observed in three dimensions by electron tomography. Drilling conditions, such as probe current, beam convergence angle, and probe position, affect the formation rate and the geometry of the pores. With a beam convergence semi-angle of α = 22 mrad, a conical shaped nanopore is formed but at α = 45 mrad, double-cone (hourglass-shaped) nanopores were produced. Nanopores with an effective diameter between 10 nm and 1.8 nm were fabricated by controlling the drilling time.

  9. A simple way to obtain backscattered electron images in a scanning transmission electron microscope.

    Science.gov (United States)

    Tsuruta, Hiroki; Tanaka, Shigeyasu; Tanji, Takayoshi; Morita, Chiaki

    2014-08-01

    We have fabricated a simple detector for backscattered electrons (BSEs) and incorporated the detector into a scanning transmission electron microscope (STEM) sample holder. Our detector was made from a 4-mm(2) Si chip. The fabrication procedure was easy, and similar to a standard transmission electron microscopy (TEM) sample thinning process based on ion milling. A TEM grid containing particle objects was fixed to the detector with a silver paste. Observations were carried out using samples of Au and latex particles at 75 and 200 kV. Such a detector provides an easy way to obtain BSE images in an STEM. © The Author 2014. Published by Oxford University Press on behalf of The Japanese Society of Microscopy. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Scanning tunnel microscopic image of tungsten (100) and (110) real surfaces and nature of conduction electron reflection

    International Nuclear Information System (INIS)

    Pryadkin, S.L.; Tsoj, V.S.

    1988-01-01

    The electrically polished (100) and (110) surfaces of tungsten are studied with the aid of a scanning tunnel microscope at atmospheric pressure. The (110) surface consists of a large number of atomically plane terraces whereas the (100) surface is faceted. The scanning tunnel microscope data can explain such results of experiments on transverse electron focussing as the strong dependence of the probability for specular reflection of conduction electrons scattered by the (100) surface on the electron de Broglie wavelength and the absence of a dependence of the probability for specular reflection on the wavelength for the (110) surface

  11. Electron microscopic analysis of rotavirus assembly-replication intermediates

    International Nuclear Information System (INIS)

    Boudreaux, Crystal E.; Kelly, Deborah F.; McDonald, Sarah M.

    2015-01-01

    Rotaviruses (RVs) replicate their segmented, double-stranded RNA genomes in tandem with early virion assembly. In this study, we sought to gain insight into the ultrastructure of RV assembly-replication intermediates (RIs) using transmission electron microscopy (EM). Specifically, we examined a replicase-competent, subcellular fraction that contains all known RV RIs. Three never-before-seen complexes were visualized in this fraction. Using in vitro reconstitution, we showed that ~15-nm doughnut-shaped proteins in strings were nonstructural protein 2 (NSP2) bound to viral RNA transcripts. Moreover, using immunoaffinity-capture EM, we revealed that ~20-nm pebble-shaped complexes contain the viral RNA polymerase (VP1) and RNA capping enzyme (VP3). Finally, using a gel purification method, we demonstrated that ~30–70-nm electron-dense, particle-shaped complexes represent replicase-competent core RIs, containing VP1, VP3, and NSP2 as well as capsid proteins VP2 and VP6. The results of this study raise new questions about the interactions among viral proteins and RNA during the concerted assembly–replicase process. - Highlights: • Rotaviruses replicate their genomes in tandem with early virion assembly. • Little is known about rotavirus assembly-replication intermediates. • Assembly-replication intermediates were imaged using electron microscopy

  12. Electron microscopic analysis of rotavirus assembly-replication intermediates

    Energy Technology Data Exchange (ETDEWEB)

    Boudreaux, Crystal E.; Kelly, Deborah F. [Virginia Tech Carilion School of Medicine and Research Institute, Roanoke, VA (United States); McDonald, Sarah M., E-mail: mcdonaldsa@vtc.vt.edu [Virginia Tech Carilion School of Medicine and Research Institute, Roanoke, VA (United States); Department of Biomedical Sciences and Pathobiology, Virginia—Maryland Regional College of Veterinary Medicine, Blacksburg, VA (United States)

    2015-03-15

    Rotaviruses (RVs) replicate their segmented, double-stranded RNA genomes in tandem with early virion assembly. In this study, we sought to gain insight into the ultrastructure of RV assembly-replication intermediates (RIs) using transmission electron microscopy (EM). Specifically, we examined a replicase-competent, subcellular fraction that contains all known RV RIs. Three never-before-seen complexes were visualized in this fraction. Using in vitro reconstitution, we showed that ~15-nm doughnut-shaped proteins in strings were nonstructural protein 2 (NSP2) bound to viral RNA transcripts. Moreover, using immunoaffinity-capture EM, we revealed that ~20-nm pebble-shaped complexes contain the viral RNA polymerase (VP1) and RNA capping enzyme (VP3). Finally, using a gel purification method, we demonstrated that ~30–70-nm electron-dense, particle-shaped complexes represent replicase-competent core RIs, containing VP1, VP3, and NSP2 as well as capsid proteins VP2 and VP6. The results of this study raise new questions about the interactions among viral proteins and RNA during the concerted assembly–replicase process. - Highlights: • Rotaviruses replicate their genomes in tandem with early virion assembly. • Little is known about rotavirus assembly-replication intermediates. • Assembly-replication intermediates were imaged using electron microscopy.

  13. Spherical aberration correction in a scanning transmission electron microscope using a sculpted thin film.

    Science.gov (United States)

    Shiloh, Roy; Remez, Roei; Lu, Peng-Han; Jin, Lei; Lereah, Yossi; Tavabi, Amir H; Dunin-Borkowski, Rafal E; Arie, Ady

    2018-06-01

    Nearly eighty years ago, Scherzer showed that rotationally symmetric, charge-free, static electron lenses are limited by an unavoidable, positive spherical aberration. Following a long struggle, a major breakthrough in the spatial resolution of electron microscopes was reached two decades ago by abandoning the first of these conditions, with the successful development of multipole aberration correctors. Here, we use a refractive silicon nitride thin film to tackle the second of Scherzer's constraints and demonstrate an alternative method for correcting spherical aberration in a scanning transmission electron microscope. We reveal features in Si and Cu samples that cannot be resolved in an uncorrected microscope. Our thin film corrector can be implemented as an immediate low cost upgrade to existing electron microscopes without re-engineering of the electron column or complicated operation protocols and can be extended to the correction of additional aberrations. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Imaging single atoms using secondary electrons with an aberration-corrected electron microscope.

    Science.gov (United States)

    Zhu, Y; Inada, H; Nakamura, K; Wall, J

    2009-10-01

    Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40% (refs 3-8). In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM (refs 10-12). Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

  15. Complex composition film condensation in the sluice device of an electron microscope

    International Nuclear Information System (INIS)

    Kukuev, V.I.; Lesovoj, M.V.; Vlasov, D.A.; Malygin, M.V.; Domashevskaya, Eh.P.; Tomashpol'skij, Yu.Ya.

    1994-01-01

    Based on the sluice device of an electron microscope a system is developed for material laser evaporation and vapor condensation on a substrate, situated in the microscope specimen holder. Substrate heating by laser radiation to 100 deg C is used. The system is applied for investigating growth of high-temperature superconductor films

  16. Differential ultrahigh-vacuum pump for electron microscope

    International Nuclear Information System (INIS)

    Kroshkov, A.A.; Aseev, A.L.; Baranova, E.A.; Latyshev, A.V.; Yakushenko, O.A.

    1985-01-01

    A differential cryogenic pump for the JEM-7A microscope is described. It reduces the vacuum pressure in the region of the specimen. The device allows tilting and movement of the specimen, direct electrical heating, measurement of specimen temperature, and deposition of films of various substances on the specimen surface. A diagram of the pump shows its placement in the objective chamber of the microscope. The fittings are equipped with bellows and provide for input and output of liquid nitrogen or liquid-helium vapor coolants. The enumerated results attest to a reduction of residual atmospheric pressure in the area of the specimen and the possibility of producing a pure silicon surface in the described device

  17. Scanning Electron Microscopic Hair Shaft Analysis in Ectodermal Dysplasia Syndromes.

    Science.gov (United States)

    Hirano-Ali, Stefanie A; Reed, Ashley M; Rowan, Brandon J; Sorrells, Timothy; Williams, Judith V; Pariser, David M; Hood, Antoinette F; Salkey, Kimberly

    2015-01-01

    The objective of the current study was to catalog hair shaft abnormalities in individuals with ectodermal dysplasia (ED) syndromes using scanning electron microscopy (SEM) and to compare the findings with those in unaffected controls. This is the second of a two-part study, the first of which used light microscopy as the modality and was previously published. Scanning electron microscopy was performed in a blinded manner on hair shafts from 65 subjects with seven types of ED syndromes and 41 unaffected control subjects. Assessment was performed along the length of the shaft and in cross section. Hair donations were collected at the 28th Annual National Family Conference held by the National Foundation for Ectodermal Dysplasia. Control subjects were recruited from a private dermatology practice and an academic children's hospital outpatient dermatology clinic. SEM identified various pathologic hair shaft abnormalities in each type of ED and in control patients. When hairs with all types of ED were grouped together and compared with those of control patients, the difference in the presence of small diameter and shallow and deep grooves was statistically significant (p < 0.05). When the EDs were separated according to subtype, statistically significant findings were also seen. SEM is a possible adjuvant tool in the diagnosis of ED syndromes. There are significant differences, with high specificity, between the hairs of individuals with ED and those of control subjects and between subtypes. © 2015 Wiley Periodicals, Inc.

  18. Bright-field scanning confocal electron microscopy using a double aberration-corrected transmission electron microscope.

    Science.gov (United States)

    Wang, Peng; Behan, Gavin; Kirkland, Angus I; Nellist, Peter D; Cosgriff, Eireann C; D'Alfonso, Adrian J; Morgan, Andrew J; Allen, Leslie J; Hashimoto, Ayako; Takeguchi, Masaki; Mitsuishi, Kazutaka; Shimojo, Masayuki

    2011-06-01

    Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Evolutionary developments in x ray and electron energy loss microanalysis instrumentation for the analytical electron microscope

    Science.gov (United States)

    Zaluzec, Nester J.

    Developments in instrumentation for both X ray Dispersive and Electron Energy Loss Spectroscopy (XEDS/EELS) over the last ten years have given the experimentalist a greatly enhanced set of analytical tools for characterization. Microanalysts have waited for nearly two decades now in the hope of getting a true analytical microscope and the development of 300 to 400 kV instruments should have allowed us to attain this goal. Unfortunately, this has not generally been the case. While there have been some major improvements in the techniques, there has also been some devolution in the modern AEM (Analytical Electron Microscope). In XEDS, the majority of today's instruments are still plagued by the hole count effect, which was first described in detail over fifteen years ago. The magnitude of this problem can still reach the 20 percent level for medium atomic number species in a conventional off-the-shelf intermediate voltage AEM. This is an absurd situation and the manufacturers should be severely criticized. Part of the blame, however, also rests on the AEM community for not having come up with a universally agreed upon standard test procedure. Fortunately, such a test procedure is in the early stages of refinement. The proposed test specimen consists of an evaporated Cr film approx. 500 to 1000A thick supported upon a 3mm diameter Molybdenum 200 micron aperture.

  20. Bright-field scanning confocal electron microscopy using a double aberration-corrected transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Peng; Behan, Gavin; Kirkland, Angus I. [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Nellist, Peter D., E-mail: peter.nellist@materials.ox.ac.uk [Department of Materials, University of Oxford, Parks Road, Oxford OX1 3PH (United Kingdom); Cosgriff, Eireann C.; D' Alfonso, Adrian J.; Morgan, Andrew J.; Allen, Leslie J. [School of Physics, University of Melbourne, Parkville, Victoria 3010 (Australia); Hashimoto, Ayako [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); Takeguchi, Masaki [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); High Voltage Electron Microscopy Station, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Mitsuishi, Kazutaka [Advanced Nano-characterization Center, National Institute for Materials Science (NIMS), 3-13 Sakura, Tsukuba 305-0003 (Japan); Quantum Dot Research Center, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Shimojo, Masayuki [High Voltage Electron Microscopy Station, NIMS, 3-13 Sakura, Tsukuba 305-0003 (Japan); Advanced Science Research Laboratory, Saitama Institute of Technology, 1690 Fusaiji, Fukaya 369-0293 (Japan)

    2011-06-15

    Scanning confocal electron microscopy (SCEM) offers a mechanism for three-dimensional imaging of materials, which makes use of the reduced depth of field in an aberration-corrected transmission electron microscope. The simplest configuration of SCEM is the bright-field mode. In this paper we present experimental data and simulations showing the form of bright-field SCEM images. We show that the depth dependence of the three-dimensional image can be explained in terms of two-dimensional images formed in the detector plane. For a crystalline sample, this so-called probe image is shown to be similar to a conventional diffraction pattern. Experimental results and simulations show how the diffracted probes in this image are elongated in thicker crystals and the use of this elongation to estimate sample thickness is explored. -- Research Highlights: {yields} The confocal probe image in a scanning confocal electron microscopy image reveals information about the thickness and height of the crystalline layer. {yields} The form of the contrast in a three-dimensional bright-field scanning confocal electron microscopy image can be explained in terms of the confocal probe image. {yields} Despite the complicated form of the contrast in bright-field scanning confocal electron microscopy, we see that depth information is transferred on a 10 nm scale.

  1. Correlation between mechanical vibrations and resolving power of an electron microscope

    International Nuclear Information System (INIS)

    Lopez, J.J.

    1975-01-01

    The mechanical vibrations of the Grenoble 1MV electron microscope are analyzed. The solutions used to obtain a stability in the order of 3.10 -6 are exposed. A resolution of 1,8A should be achieved [fr

  2. Use of high voltage electron microscope to simulate radiation damage by neutrons

    International Nuclear Information System (INIS)

    Mayer, R.M.

    1976-01-01

    The use of the high voltage electron microscope to simulate radiation damage by neutrons is briefly reviewed. This information is important in explaining how alloying affects void formation during neutron irradiation

  3. A scanning electron microscope study of the pecten oculi of the black kite (Milvus migrans): possible involvement of melanosomes in protecting the pecten against damage by ultraviolet light

    International Nuclear Information System (INIS)

    Kiama, S.G.; Maina, J.N.; Bhattacharjee, J.; Weyrauch, K.D.

    1994-01-01

    The pecten oculi of the black kite (Milvus migrans), a diurnally active bird of prey, has been examined by scanning electron microscopy. In this species the pecten consists of 12 highly vascularised pleats, held together apically by a heavily pigmented 'bridge' and projects freely into the vitreous body in the ventral part of the eye cup. Ascending and descending blood vessels of varying calibre, together with a profuse network of capillaries, essentially constitute the vascular framework of the pecten. A distinct distribution of melansomes is discernible on the pecten, the concentration being highest at its apical end, moderate at the crest of the pleats and least at the basal and lateral margins. Overlying and within the vascular network, a close association between blood vessels and melanocytes is evident. It is conjectured that such an association may have evolved to augment the structural reinforcement of this nutritive organ in order to keep it firmly erectile within the gel-like vitreous. Such erectility may be an essential prerequisite for its optimal functioning, as well as in its overt use as a protective shield against the effects of ultraviolet light, which otherwise might lead to damage of the pectineal vessels. (author)

  4. A scanning electron microscope study of the pecten oculi of the black kite (Milvus migrans): possible involvement of melanosomes in protecting the pecten against damage by ultraviolet light

    Energy Technology Data Exchange (ETDEWEB)

    Kiama, S.G.; Maina, J.N. [University Coll., Nairobi (Kenya). Faculty of Veterinary Science; Bhattacharjee, J. [Egerton Univ., Njoro (Kenya). Dept. of Zoology; Weyrauch, K.D. [Free University of Berlin (Germany). Inst. of Veterinary Anatomy

    1994-12-01

    The pecten oculi of the black kite (Milvus migrans), a diurnally active bird of prey, has been examined by scanning electron microscopy. In this species the pecten consists of 12 highly vascularised pleats, held together apically by a heavily pigmented `bridge` and projects freely into the vitreous body in the ventral part of the eye cup. Ascending and descending blood vessels of varying calibre, together with a profuse network of capillaries, essentially constitute the vascular framework of the pecten. A distinct distribution of melansomes is discernible on the pecten, the concentration being highest at its apical end, moderate at the crest of the pleats and least at the basal and lateral margins. Overlying and within the vascular network, a close association between blood vessels and melanocytes is evident. It is conjectured that such an association may have evolved to augment the structural reinforcement of this nutritive organ in order to keep it firmly erectile within the gel-like vitreous. Such erectility may be an essential prerequisite for its optimal functioning, as well as in its overt use as a protective shield against the effects of ultraviolet light, which otherwise might lead to damage of the pectineal vessels. (author).

  5. Field emission from individual multiwalled carbon nanotubes prepared in an electron microscope

    NARCIS (Netherlands)

    de Jonge, N.; van Druten, N.J.

    2003-01-01

    Individual multiwalled carbon nanotube field emitters were prepared in a scanning electron microscope. The angular current density, energy spectra, and the emission stability of the field-emitted electrons were measured. An estimate of the electron source brightness was extracted from the

  6. An aberration corrected photoemission electron microscope at the advanced light source

    International Nuclear Information System (INIS)

    Feng, J.; MacDowell, A.A.; Duarte, R.; Doran, A.; Forest, E.; Kelez, N.; Marcus, M.; Munson, D.; Padmore, H.; Petermann, K.; Raoux, S.; Robin, D.; Scholl, A.; Schlueter, R.; Schmid, P.; Stohr, J.; Wan, W.; Wei, D.H.; Wu, Y.

    2003-01-01

    Design of a new aberration corrected Photoemission electron microscope PEEM3 at the Advanced Light Source is outlined. PEEM3 will be installed on an elliptically polarized undulator beamline and will be used for the study of complex materials at high spatial and spectral resolution. The critical components of PEEM3 are the electron mirror aberration corrector and aberration-free magnetic beam separator. The models to calculate the optical properties of the electron mirror are discussed. The goal of the PEEM3 project is to achieve the highest possible transmission of the system at resolutions comparable to our present PEEM2 system (50 nm) and to enable significantly higher resolution, albeit at the sacrifice of intensity. We have left open the possibility to add an energy filter at a later date, if it becomes necessary driven by scientific need to improve the resolution further

  7. Probing plasmons in three dimensions by combining complementary spectroscopies in a scanning transmission electron microscope

    International Nuclear Information System (INIS)

    Hachtel, J A; Haglund, R F; Pantelides, S T; Marvinney, C; Mayo, D; Mouti, A; Lupini, A R; Chisholm, M F; Mu, R; Pennycook, S J

    2016-01-01

    The nanoscale optical response of surface plasmons in three-dimensional metallic nanostructures plays an important role in many nanotechnology applications, where precise spatial and spectral characteristics of plasmonic elements control device performance. Electron energy loss spectroscopy (EELS) and cathodoluminescence (CL) within a scanning transmission electron microscope have proven to be valuable tools for studying plasmonics at the nanoscale. Each technique has been used separately, producing three-dimensional reconstructions through tomography, often aided by simulations for complete characterization. Here we demonstrate that the complementary nature of the two techniques, namely that EELS probes beam-induced electronic excitations while CL probes radiative decay, allows us to directly obtain a spatially- and spectrally-resolved picture of the plasmonic characteristics of nanostructures in three dimensions. The approach enables nanoparticle-by-nanoparticle plasmonic analysis in three dimensions to aid in the design of diverse nanoplasmonic applications. (paper)

  8. Instrumentation at the National Center for Electron Microscopy: the Atomic Resolution Microscope

    International Nuclear Information System (INIS)

    Gronsky, R.; Thomas, G.

    1983-01-01

    The Atomic Resolution Microscope (ARM) is one of two unique high voltage electron microscopes at the Lawrence Berkeley Laboratory's National Center for Electron Microscopy (NCEM). The latest results from this new instrument which was manufactured by JEOL, Ltd. to the performance specifications of the NCEM, delivered in January of 1983, and soon to be open to access by the entire microscopy community are given. Details of its history and development are given and its performance specifications are reviewed

  9. Cells at risk for the production of bone tumors in man: an electron microscope study of the endosteal surface of control bone and bone from a human radium case

    International Nuclear Information System (INIS)

    Lloyd, E.L.; Henning, C.B.

    1979-01-01

    The endosteal cells of bone from a radium dial worker are documented for the first time by electron microscopy. Fresh samples of bone and tumor tissue from the femur were made available as a result of amputation for a fibrosarcoma in the region of the right knee joint. Bone was examined from a site proximal to the tumor where no invasion of tumor tissue was evident. The patient, who was exposed at age 16 in 1918, died in 1978 with a terminal body burden, calculated to be 1.2 μCi, 226 Ra. A sample of bone, also obtained at amputation from an unirradiated control patient, age 65, was examined from the same site in the femur. A comparison of the bone bone-marrow interface from the two patients showed that, unlike the control bone where cells were seen close to bone mineral, an intervening fibrotic layer was interposed between the marrow cells and the bone mineral in the radium bone. This layer varied in thickness up to 50 μm and was usually acellular, although cell remnants and occasionally cells, which appeared viable, were seen. Autoradiographs of sections of bone adjacent to those used for the electron microscope studies are being evaluated

  10. Electron microscope observation of single - crystalline beryllium thin foils

    International Nuclear Information System (INIS)

    Antolin, J.; Poirier, J.P.; Dupouy, J.M.

    1965-01-01

    Thin foils prepared from single crystalline beryllium simples deformed at room temperature, have been observed by transmission electron microscopy. The various deformation modes have been investigated separately, from their early stages and their characteristic dislocation configurations have been observed. Basal slip is characterized at is outset by the presence of numerous dipoles and elongated prismatic loops. More pronounced cold work leads to the formation of dislocation tangles and bundles which eventually give a cellular structure. Prismatic slip begins by the cross-slip of dislocations from the basal plane into the prismatic plane. A cellular structure is equally observed in heavily deformed samples. Sessile dislocations have been observed in twin boundaries; they are produced by reactions between slip dislocations and twin dislocations. Finally, the study of samples quenched from 1100 deg. C and annealed at 200 deg. C has shown that the observed loops lie in prismatic planes and have a Burgers vector b 1/3 . (authors) [fr

  11. Dynamic investigation of electron trapping and charge decay in electron-irradiated Al sub 2 O sub 3 in a scanning electron microscope: Methodology and mechanisms

    CERN Document Server

    Fakhfakh, S; Belhaj, M; Fakhfakh, Z; Kallel, A; Rau, E I

    2002-01-01

    The charging and discharging of polycrystalline Al sub 2 O sub 3 submitted to electron-irradiation in a scanning electron microscope (SEM) are investigated by means of the displacement current method. To circumvent experimental shortcomings inherent to the use of the basic sample holder, a redesign of the latter is proposed and tests are carried out to verify its operation. The effects of the primary beam accelerating voltage on charging, flashover and discharging phenomena during and after electron-irradiation are studied. The experimental results are then analyzed. In particular, the divergence between the experimental data and those predicted by the total electron emission yield approach (TEEYA) is discussed. A partial discharge was observed immediately after the end of the electron-irradiation exposure. The experimental data suggests, that the discharge is due to the evacuation to the ground, along the insulator surface, of released electrons from shallow traps at (or in the close vicinity of) the insulat...

  12. Microscopic study of edema in hydatidiform mole

    Directory of Open Access Journals (Sweden)

    Olivar C. Castejón

    2014-09-01

    Full Text Available Objectives: the purpose of this study is to use light microscopy and scanning electron microscopy to determine the effect of edema on the structure of the molar vesicle. Methods: samples were taken from the complete hydatidiform mole and processed using conventional light and scanning electron microscopy techniques and an observation protocol that identified four variables: factors underlying the development of edema; the condition of the trophoblast basement membrane, development of the villi, accumulation and degeneration of sulphated mucosubstances at stromal level. Results: light microscopy showed a permeable trophoblastic basement membrane, a swollen syncytium, edematous regions disorganizating the stromal region and causing ischemic necrosis of cells. Using scanning electron microscopy, the basement membrane was found to be distended and thickened, with large irregular holes for the entry and movement of liquid, leaving a wide range of fluids during the influx process and depriving stromal cells of nutrition. Conclusions: a new three-dimensional view of the changes brought about by the entry of fluids into the stroma of molar hydropic vesicles was provided by scanning electron microscopy and confirmed by light microscopy, thereby explaining the changes occurring at the level of the stroma as an effect of the edema.

  13. Performance of ultrahigh resolution electron microscope JEM-4000EX and some applications of high Tc superconductors

    International Nuclear Information System (INIS)

    Honda, T.; Ibe, K.; Ishida, Y.; Kersker, M.M.

    1989-01-01

    The high resolution electron microscope is powerful for modern materials science because of its direct observation capability for the atomic structure of materials. the JEM-4000EX, a 400 kV accelerating voltage electron microscope whose objective lens has a 1 mm spherical aberration coefficient, has a 0.168 nm theoretical resolving power. Using this microscope, atomic structure images of high Tc superconductor such as Y-Ba-Cu-O, Bi-Ca-Sr-Cu-O and Tl-Ca-Ba-Cu-O are reported

  14. Scanning electron microscope - some aspects of the instrument and its applications

    International Nuclear Information System (INIS)

    Thatte, M.R.

    1976-01-01

    Development of the science of microscopy leading to three different types of microscopes - the optical, the conventional transmission electron microscope (CTEM) and the scanning electron microscope(SEM) has been discussed. Special advantages of the SEM in the solution of problems in industrial laboratories are mentioned. A brief reference to the latest instruments announced by Siemens AG shows the modern trends in the technique. A close similarity in image building between SEM and television is indicated. Operational anatomy of the SEM is reviewed. (author)

  15. Manipulation of nanoparticles of different shapes inside a scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Boris Polyakov

    2014-02-01

    Full Text Available In this work polyhedron-like gold and sphere-like silver nanoparticles (NPs were manipulated on an oxidized Si substrate to study the dependence of the static friction and the contact area on the particle geometry. Measurements were performed inside a scanning electron microscope (SEM that was equipped with a high-precision XYZ-nanomanipulator. To register the occurring forces a quartz tuning fork (QTF with a glued sharp probe was used. Contact areas and static friction forces were calculated by using different models and compared with the experimentally measured force. The effect of NP morphology on the nanoscale friction is discussed.

  16. Serotonergic synaptic input to facial motoneurons: localization by electron-microscopic autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Aghajanian, G K; McCall, R B [Yale Univ., New Haven, CT (USA). School of Medicine

    1980-12-01

    Serotonergic nerve terminals in the facial motor nucleus were labelled with (/sup 3/H)5-hydroxytryptamine. When serotonergic nerve terminals were destroyed (by the selective neurotoxin 5,7-dihydroxytryptamine) the labelling was lost. By electron-microscopic autoradiography, labelled serotonergic terminals were found to make axo-dendritic or axo-somatic junctions with facial motor neurons. No axo-axonic junctions were observed. These morphological findings are consistent with physiological studies which indicate that 5-hydroxytryptamine facilitates the excitation of facial motoneurons through a direct postsynaptic action.

  17. Atmospheric scanning electron microscope observes cells and tissues in open medium through silicon nitride film.

    Science.gov (United States)

    Nishiyama, Hidetoshi; Suga, Mitsuo; Ogura, Toshihiko; Maruyama, Yuusuke; Koizumi, Mitsuru; Mio, Kazuhiro; Kitamura, Shinichi; Sato, Chikara

    2010-03-01

    Direct observation of subcellular structures and their characterization is essential for understanding their physiological functions. To observe them in open environment, we have developed an inverted scanning electron microscope with a detachable, open-culture dish, capable of 8 nm resolution, and combined with a fluorescence microscope quasi-simultaneously observing the same area from the top. For scanning electron microscopy from the bottom, a silicon nitride film window in the base of the dish maintains a vacuum between electron gun and open sample dish while allowing electrons to pass through. Electrons are backscattered from the sample and captured by a detector under the dish. Cells cultured on the open dish can be externally manipulated under optical microscopy, fixed, and observed using scanning electron microscopy. Once fine structures have been revealed by scanning electron microscopy, their component proteins may be identified by comparison with separately prepared fluorescence-labeled optical microscopic images of the candidate proteins, with their heavy-metal-labeled or stained ASEM images. Furthermore, cell nuclei in a tissue block stained with platinum-blue were successfully observed without thin-sectioning, which suggests the applicability of this inverted scanning electron microscope to cancer diagnosis. This microscope visualizes mesoscopic-scale structures, and is also applicable to non-bioscience fields including polymer chemistry. (c) 2010 Elsevier Inc. All rights reserved.

  18. Construction of a four tip scanning tunneling microscope/scanning electron microscope combination and conductivity measurements of silicide nanowires

    International Nuclear Information System (INIS)

    Zubkov, Evgeniy

    2013-01-01

    In this work the combination of a four-tip scanning tunneling microscope with a scanning electron microscope is presented. By means of this apparatus it is possible to perform the conductivity measurements on the in-situ prepared nanostructures in ultra-high vacuum. With the aid of a scanning electron microscope (SEM), it becomes possible to position the tunneling tips of the four-tip scanning tunneling microscope (STM), so that an arrangement for a four-point probe measurement on nanostructures can be obtained. The STM head was built according to the novel coaxial Beetle concept. This concept allows on the one hand, a very compact arrangement of the components of the STM and on the other hand, the new-built STM head has a good mechanical stability, in order to achieve atomic resolution with all four STM units. The atomic resolution of the STM units was confirmed by scanning a Si(111)-7 x 7 surface. The thermal drift during the STM operation, as well as the resonant frequencies of the mechanical structure of the STM head, were determined. The scanning electron microscope allows the precise and safe navigation of the tunneling tips on the sample surface. Multi tip spectroscopy with up to four STM units can be performed synchronously. To demonstrate the capabilities of the new-built apparatus the conductivity measurements were carried out on metallic yttrium silicide nanowires. The nanowires were prepared by the in-situ deposition of yttrium on a heated Si(110) sample surface. Current-voltage curves were recorded on the nanowires and on the wetting layer in-between. The curves indicate an existence of the Schottky barrier between the yttrium silicide nanowires and the silicon bulk. By means of the two-tip measurements with a gate, the insulating property of the Schottky barrier has been confirmed. Using this Schottky barrier, it is possible to limit the current to the nanowire and to prevent it from flowing through the silicon bulk. A four-tip resistance measurement

  19. Comparison of Electron Imaging Modes for Dimensional Measurements in the Scanning Electron Microscope.

    Science.gov (United States)

    Postek, Michael T; Vladár, András E; Villarrubia, John S; Muto, Atsushi

    2016-08-01

    Dimensional measurements from secondary electron (SE) images were compared with those from backscattered electron (BSE) and low-loss electron (LLE) images. With the commonly used 50% threshold criterion, the lines consistently appeared larger in the SE images. As the images were acquired simultaneously by an instrument with the capability to operate detectors for both signals at the same time, the differences cannot be explained by the assumption that contamination or drift between images affected the SE, BSE, or LLE images differently. Simulations with JMONSEL, an electron microscope simulator, indicate that the nanometer-scale differences observed on this sample can be explained by the different convolution effects of a beam with finite size on signals with different symmetry (the SE signal's characteristic peak versus the BSE or LLE signal's characteristic step). This effect is too small to explain the >100 nm discrepancies that were observed in earlier work on different samples. Additional modeling indicates that those discrepancies can be explained by the much larger sidewall angles of the earlier samples, coupled with the different response of SE versus BSE/LLE profiles to such wall angles.

  20. Path-separated electron interferometry in a scanning transmission electron microscope

    Science.gov (United States)

    Yasin, Fehmi S.; Harvey, Tyler R.; Chess, Jordan J.; Pierce, Jordan S.; McMorran, Benjamin J.

    2018-05-01

    We report a path-separated electron interferometer within a scanning transmission electron microscope. In this setup, we use a nanofabricated grating as an amplitude-division beamsplitter to prepare multiple spatially separated, coherent electron probe beams. We achieve path separations of 30 nm. We pass the  +1 diffraction order probe through amorphous carbon while passing the 0th and  ‑1 orders through vacuum. The probes are then made to interfere via imaging optics, and we observe an interference pattern at the CCD detector with up to 39.7% fringe visibility. We show preliminary experimental results in which the interference pattern was recorded during a 1D scan of the diffracted probes across a test phase object. These results qualitatively agree with a modeled interference predicted by an independent measurement of the specimen thickness. This experimental design can potentially be applied to phase contrast imaging and fundamental physics experiments, such as an exploration of electron wave packet coherence length.

  1. Light and electron microscope assessment of the lytic activity of ...

    African Journals Online (AJOL)

    The Microcystis cells were exposed to copper, B. mycoides B16 and Triton X-100, in order to ascertain the level of cell membrane damage. The membrane cell damage ... The electron microscopy observations appeared to reveal at least two mechanisms of Microcystis lysis (contact and parasitism). The light and electron ...

  2. A new program for the design of electron microscopes

    Czech Academy of Sciences Publication Activity Database

    Lencová, Bohumila; Zlámal, J.

    2008-01-01

    Roč. 1, č. 1 (2008), s. 315-324 ISSN 1875-3892. [International Conference on Charged Particle Optics /7./ CPO-7. Cambridge, 24.07.2006-28.07.2006] Institutional research plan: CEZ:AV0Z20650511 Keywords : finite element method * electron lenses and deflectors * computer-aided design * user interface Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  3. Dynamics of Supported Metal Nanoparticles Observed in a CS Corrected Environmental Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Dunin-Borkowski, Rafal E.; Wagner, Jakob Birkedal

    resulting in the formation of larger particles and a loss of catalytic performance. Several models of sintering in different systems have been put forward [1,2]. However, most investigations have been post mortem studies, revealing only the final state of the catalyst. Transmission electron microscopy (TEM....... The combined capabilities of ETEM and image CS correction provide unique possibilities to study this relationship. However, in order to fully quantify image contrast from such experiments, a deeper understanding of the scattering of fast electrons in the presence of gas molecules in the pole piece gap...... of the microscope is needed. As industrial catalysts are usually complex high surface area materials, they are often not suited for fundamental studies. For this purpose, model systems consisting of gold nanoparticles on sheets of low surface area boron nitride and graphite supports were produced. Sheets...

  4. Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

    Energy Technology Data Exchange (ETDEWEB)

    Eisenstein, Alon; Goh, M. Cynthia [Department of Chemistry and Institute for Optical Sciences, University of Toronto, 80 St. George Street, Toronto M5S 3H6 (Canada)

    2012-03-15

    A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

  5. Contrast and decay of cathodoluminescence from phosphor particles in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Engelsen, Daniel den; Harris, Paul G.; Ireland, Terry G., E-mail: terry.ireland@brunel.ac.uk; Fern, George R.; Silver, Jack

    2015-10-15

    Cathodoluminescence (CL) studies are reported on phosphors in a field emission scanning electron microscope (FESEM). ZnO: Zn and other luminescent powders manifest a bright ring around the periphery of the particles: this ring enhances the contrast. Additionally, particles resting on top of others are substantially brighter than underlying ones. These phenomena are explained in terms of the combined effects of electrons backscattered out of the particles, together with light absorption by the substrate. The contrast is found to be a function of the particle size and the energy of the primary electrons. Some phosphor materials exhibit a pronounced comet-like structure at high scan rates in a CL-image, because the particle continues to emit light after the electron beam has moved to a position without phosphor material. Image analysis has been used to study the loss of brightness along the tail and hence to determine the decay time of the materials. The effect of phosphor saturation on the determination of decay times by CL-microscopy was also investigated. - Highlights: • Contrast enhancement are observed in secondary electron and cathodoluminescent images of phosphor particles sitting on top of others. • Backscattered electrons largely explain the observed contrast enhancement. • After glow effects in CL-micrographs of phosphors enable the determination of decay times. • Phosphor saturation can be used to determine the decay time of individual spectral transitions.

  6. Light and scanning electron microscopic studies of Unionicola tetrafurcatus (Acari: Unionicolidae) infecting four freshwater bivalve species with referring to histopathological effect on its hosts.

    Science.gov (United States)

    Abdel-Gaber, Rewaida; Fol, Mona; Al Quraishy, Saleh

    2018-05-08

    Water mites of the genus Unionicola are the most common symbionts of freshwater bivalves. During the current investigation, a total of 120 live freshwater mussels [Corbicula fluminea (Veneroida), Coelatura aegyptiaca (Unionoidea) Mutela rostrata and Chambardia rubens (Mutelidae)], were collected from 2 localities in Tura (Helwan Governorate) and El Kanater (Qaluobiya Governorate), Egypt. Only 3 of the 4 bivalve species listed are considered freshwater bivalves (members of Unionoidea). While, C. fluminea belong to the family Cyrenidae within Veneroida. The collected mussels were dissected and examined for the presence of unionicolid mites. It was found that 30.83% (37/120) were infected with a single mite species Unionicola tetrafurcatus (Unionicolidae). The highest prevalence was observed during the summer with 83.33% (25/30), whereas the least was observed in autumn, i.e. 33.33% (10/30). Mites were recovered from the gills, gonads, and visceral mass of mussel hosts. gills of host mussels were the primary site of oviposition for unionicola mites. Smaller bivalves in size had significantly greater numbers of mites than larger ones in size. Numbers of mites per host species was variable and the highest prevalence level of 83.33% (25/30) was recorded in C. fluminea, while, the lowest one of 16.66% (5/30) was found in C. rubens. Morphological and morphometric characterizations of mites revealed some differences between the present species and other related Unionicola. Histopathological responses of host mussels to the eggs, larvae, and cuticular remnants of U. tetrafurcatus were also studied. Therefore, the present study demonstrated that freshwater bivalves have a new host and locality records for infection with U. tetrafurcatus. Future studies are recommended to include advanced molecular characteristics for these mites.

  7. Trypanosoma (megatrypanum) melophagium in the sheep ked, Melophagus ovinus. A scanning electron microscope (SEM) study of the parasites and the insect gut wall surfaces.

    Science.gov (United States)

    Molyneux, D H; Selkirk, M; Lavin, D

    1978-12-01

    A description of the different stages of Trypanosoma (M.) melophagium in different regions of the gut of the sheep ked (Melophagus ovinus) as observed by the SEM is presented. The extensive pile carpet or palisade colonization of the midgut and pylorus is described. The method of attachment and the relationship of the parasites to the microvilli in the midgut and the cuticle of the pylorus and ileum observed by other methods are confirmed. The micro-structure of the surfaces themselves in the regions of the gut to which parasites attach are described. The use of the technique for the study of other similar systems is discussed.

  8. Hartmann characterization of the PEEM-3 aberration-corrected X-ray photoemission electron microscope.

    Science.gov (United States)

    Scholl, A; Marcus, M A; Doran, A; Nasiatka, J R; Young, A T; MacDowell, A A; Streubel, R; Kent, N; Feng, J; Wan, W; Padmore, H A

    2018-05-01

    Aberration correction by an electron mirror dramatically improves the spatial resolution and transmission of photoemission electron microscopes. We will review the performance of the recently installed aberration corrector of the X-ray Photoemission Electron Microscope PEEM-3 and show a large improvement in the efficiency of the electron optics. Hartmann testing is introduced as a quantitative method to measure the geometrical aberrations of a cathode lens electron microscope. We find that aberration correction leads to an order of magnitude reduction of the spherical aberrations, suggesting that a spatial resolution of below 100 nm is possible at 100% transmission of the optics when using x-rays. We demonstrate this improved performance by imaging test patterns employing element and magnetic contrast. Published by Elsevier B.V.

  9. [Arterial repair after mechanical injury by migrating fourth-stage larvae of Strongylus vulgaris in the horse (a light and electron microscopic study) (author's transl)].

    Science.gov (United States)

    Pauli, B; Althaus, S; Von Tscharner, C

    1975-08-01

    Migrating fourth-stage larvae of Strongylus vulgaris, a parasite of equines, damage the intima of the anterior mesenteric artery and its larger branches and induce thrombus formation on the injured sites. As the time of larval passage through each of these branches has been exactly determined in earlier experiments, the aim of the present studies is to contribute to a more complete understanding of repair mechanisms in the process of time after thrombotic vascular injuries. five foals were separated individually to specially cleaned stables and given anthelmintic treatment till the age of one year. One foal was infected per os with 350, the second with 500 and the remaining three with 1,000 third-stage larvae of Strongylus vulgaris...

  10. Moissanite (SiC) with metal-silicide and silicon inclusions from tuff of Israel: Raman spectroscopy and electron microscope studies

    Science.gov (United States)

    Dobrzhinetskaya, Larissa; Mukhin, Pavel; Wang, Qin; Wirth, Richard; O'Bannon, Earl; Zhao, Wenxia; Eppelbaum, Lev; Sokhonchuk, Tatiana

    2018-06-01

    Here, we present studies of natural SiC that occurs in situ in tuff related to the Miocene alkaline basalt formation deposited in northern part of Israel. Raman spectroscopy, SEM and FIB-assisted TEM studies revealed that SiC is primarily hexagonal polytypes 4H-SiC and 6H-SiC, and that the 4H-SiC polytype is the predominant phase. Both SiC polytypes contain crystalline inclusions of silicon (Sio) and inclusions of metal-silicide with varying compositions (e.g. Si58V25Ti12Cr3Fe2, Si41Fe24Ti20Ni7V5Zr3, and Si43Fe40Ni17). The silicides crystal structure parameters match Si2TiV5 (Pm-3m space group, cubic), FeSi2Ti (Pbam space group, orthorhombic), and FeSi2 (Cmca space group, orthorhombic) respectively. We hypothesize that SiC was formed in a local ultra-reduced environment at respectively shallow depths (60-100 km), through a reaction of SiO2 with highly reducing fluids (H2O-CH4-H2-C2H6) arisen from the mantle "hot spot" and passing through alkaline basalt magma reservoir. SiO2 interacting with the fluids may originate from the walls of the crustal rocks surrounding this magmatic reservoir. This process led to the formation of SiC and accompanied by the reducing of metal-oxides to native metals, alloys, and silicides. The latter were trapped by SiC during its growth. Hence, interplate "hot spot" alkali basalt volcanism can now be included as a geological environment where SiC, silicon, and silicides can be found.

  11. MACROSCOPICAL AND MICROSCOPICAL STUDIES ON THE ...

    African Journals Online (AJOL)

    Caesalpinia crista leaves are bipinnate of about six pairs with alternate leaflets while the stem us fibrous, cylindrical hollow and prickly. Microscopical examination revealed the presence of strained cuticle, straight-walled epidermal cells, paracytic stomata, unicellular covering trichomes, fibres, prisms as well as cluster of ...

  12. Studies on the cytodifferentiation of the neuroblasts and visual cells in the chick embryo retina, using the electron-microscopic autoradiography of 3H-thymidine

    International Nuclear Information System (INIS)

    Mishima, H.; Fujita, H.

    1978-01-01

    Studies on the histogenetic analysis of cytodifferentiation of the neuroblast and visual cell in the chick embryo retina were made using the autoradiography of 3 H-thymidine. The posterior pole region of the eyeball was observed in all the animals used. The retina in a 4-day-old chick embryo consists exclusively of matrix cells forming the matrix layer. In a 5-day-old chick embryo retina, neuroblasts first differentiated from the matrix cells migrate into the outer part of the matrix layer, forming the mantle layer. The matrix cell is a homogeneous epithelial cell containing abundant free ribosomes and a poorly developed cytoplasmic membrane system in the cytoplasm. The characteristic sign of differentiation of the neuroblast is an appearance of elements of rough-surfaced endoplasmic reticulum and an indentation of the nucleus. The primitive visual cell having just lost its ability to synthesize DNA appears just beneath the pigment epithelium in a 7-day-old chick embryo, and all the cells lying beneath the pigment epithelium lose the ability to synthesize DNA at 10 days of incubation. The cytoplasmic process of the matrix cell is in contact with the adjacent one, making an apicolateral junction. When the matrix cell loses its ability to synthesize DNA, a big tentlike process extending over the level of the apicolateral junction appears. This phenomenon is considered to be a sign of differentiation from matrix cell to primitive visual cell, and this big tentlike process containing 2 centrioles is a primordium of the inner segment of the visual cell. (orig.) [de

  13. Exploring the magnetic and organic microstructures with photoemission electron microscope

    International Nuclear Information System (INIS)

    Wei, D.H.; Chan, Yuet-Loy; Hsu, Yao-Jane

    2012-01-01

    Highlights: ► PEEM with polarized photon enables additional image contrasts and physical insights. ► XMCD-based images reveal the shape-dependent domains in Ni80Fe20 microstructures. ► XLD-based images confirm the success of molecular orientation controls. ► The two interfaces in Co–Pn–Co structures are magnetically and chemically different. -- Abstract: We present photoemission electron microscopy (PEEM) studies on geometrically constrained ferromagnetic, organic, and organics–ferromagnet hybrid structures. Powered by an elliptically polarized undulator, the PEEM at Taiwan Light Source (TLS) is capable of recording polarization enhanced X-ray images and has been employed to examine the domain configurations in a lithographically patterned permalloy film as well as the orientations of pentacene molecules adsorbed on self-assembled monolayers (SAMs) modified gold surfaces. In addition, magnetic images acquired on cobalt/pentacene and pentacene/cobalt bilayers reveal that in hybrid structures the order of thin film deposition can lead to distinct domain configurations. Spectroscopic evidence further suggests that there is significant orbital hybridization at the interface where metallic cobalt was deposited directly on organic pentacene.

  14. Exploring the magnetic and organic microstructures with photoemission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Wei, D.H., E-mail: dhw@nsrrc.org.tw [National Synchrotron Radiation Research Center, Hsinchu Science Park, 30076 Hsinchu, Taiwan (China); Chan, Yuet-Loy; Hsu, Yao-Jane [National Synchrotron Radiation Research Center, Hsinchu Science Park, 30076 Hsinchu, Taiwan (China)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer PEEM with polarized photon enables additional image contrasts and physical insights. Black-Right-Pointing-Pointer XMCD-based images reveal the shape-dependent domains in Ni80Fe20 microstructures. Black-Right-Pointing-Pointer XLD-based images confirm the success of molecular orientation controls. Black-Right-Pointing-Pointer The two interfaces in Co-Pn-Co structures are magnetically and chemically different. -- Abstract: We present photoemission electron microscopy (PEEM) studies on geometrically constrained ferromagnetic, organic, and organics-ferromagnet hybrid structures. Powered by an elliptically polarized undulator, the PEEM at Taiwan Light Source (TLS) is capable of recording polarization enhanced X-ray images and has been employed to examine the domain configurations in a lithographically patterned permalloy film as well as the orientations of pentacene molecules adsorbed on self-assembled monolayers (SAMs) modified gold surfaces. In addition, magnetic images acquired on cobalt/pentacene and pentacene/cobalt bilayers reveal that in hybrid structures the order of thin film deposition can lead to distinct domain configurations. Spectroscopic evidence further suggests that there is significant orbital hybridization at the interface where metallic cobalt was deposited directly on organic pentacene.

  15. Automated grain mapping using wide angle convergent beam electron diffraction in transmission electron microscope for nanomaterials.

    Science.gov (United States)

    Kumar, Vineet

    2011-12-01

    The grain size statistics, commonly derived from the grain map of a material sample, are important microstructure characteristics that greatly influence its properties. The grain map for nanomaterials is usually obtained manually by visual inspection of the transmission electron microscope (TEM) micrographs because automated methods do not perform satisfactorily. While the visual inspection method provides reliable results, it is a labor intensive process and is often prone to human errors. In this article, an automated grain mapping method is developed using TEM diffraction patterns. The presented method uses wide angle convergent beam diffraction in the TEM. The automated technique was applied on a platinum thin film sample to obtain the grain map and subsequently derive grain size statistics from it. The grain size statistics obtained with the automated method were found in good agreement with the visual inspection method.

  16. Accurate virus quantitation using a Scanning Transmission Electron Microscopy (STEM) detector in a scanning electron microscope.

    Science.gov (United States)

    Blancett, Candace D; Fetterer, David P; Koistinen, Keith A; Morazzani, Elaine M; Monninger, Mitchell K; Piper, Ashley E; Kuehl, Kathleen A; Kearney, Brian J; Norris, Sarah L; Rossi, Cynthia A; Glass, Pamela J; Sun, Mei G

    2017-10-01

    A method for accurate quantitation of virus particles has long been sought, but a perfect method still eludes the scientific community. Electron Microscopy (EM) quantitation is a valuable technique because it provides direct morphology information and counts of all viral particles, whether or not they are infectious. In the past, EM negative stain quantitation methods have been cited as inaccurate, non-reproducible, and with detection limits that were too high to be useful. To improve accuracy and reproducibility, we have developed a method termed Scanning Transmission Electron Microscopy - Virus Quantitation (STEM-VQ), which simplifies sample preparation and uses a high throughput STEM detector in a Scanning Electron Microscope (SEM) coupled with commercially available software. In this paper, we demonstrate STEM-VQ with an alphavirus stock preparation to present the method's accuracy and reproducibility, including a comparison of STEM-VQ to viral plaque assay and the ViroCyt Virus Counter. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Instrumental Developments for In-situ Breakdown Experiments inside a Scanning Electron Microscope

    CERN Document Server

    Muranaka, T; Leifer, K; Ziemann, V

    2011-01-01

    Electrical discharges in accelerating structures are one of the key issues limiting the performance of future high energy accelerators such as the Compact Linear Collider (CLIC). Fundamental understanding of breakdown phenomena is an indispensable part of the CLIC feasibility study. The present work concerns the experimental study of breakdown using Scanning Electron Microscopes (SEMs). A SEM gives us the opportunity to achieve high electrical gradients of 1\\,kV/$\\mu$m which corresponds to 1\\,GV/m by exciting a probe needle with a high voltage power supply and controlling the positioning of the needle with a linear piezo motor. The gap between the needle tip and the surface is controlled with sub-micron precision. A second electron microscope equipped with a Focused Ion Beam (FIB) is used to create surface corrugations and to sharpen the probe needle to a tip radius of about 50\\,nm. Moreover it is used to prepare cross sections of a voltage breakdown area in order to study the geometrical surface damages as w...

  18. Accelerator-based Single-shot Ultrafast Transmission Electron Microscope with Picosecond Temporal Resolution and Nanometer Spatial Resolution

    OpenAIRE

    Xiang, D.; Fu, F.; Zhang, J.; Huang, X.; Wang, L.; Wang, X.; Wan, W.

    2014-01-01

    We present feasibility study of an accelerator-based ultrafast transmission electron microscope (u-TEM) capable of producing a full field image in a single-shot with simultaneous picosecond temporal resolution and nanometer spatial resolution. We study key physics related to performance of u-TEMs, and discuss major challenges as well as possible solutions for practical realization of u-TEMs. The feasibility of u-TEMs is confirmed through simulations using realistic electron beam parameters. W...

  19. Scanning Electron Microscopic Studies of Clinostomum tilapiae ...

    African Journals Online (AJOL)

    http://dx.doi.org/10.4314/tv.v22i1.4544 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL · AJOL's Partners · Terms and Conditions of Use · Contact AJOL · News. OTHER RESOURCES... for Researchers · for Journals · for Authors · for Policy Makers ...

  20. Mesotherapy for facial skin rejuvenation: a clinical, histologic, and electron microscopic evaluation.

    Science.gov (United States)

    Amin, Snehal P; Phelps, Robert G; Goldberg, David J

    2006-12-01

    Mesotherapy, as broadly defined, represents a variety of minimally invasive techniques in which medications are directly injected into the skin and underlying tissue in order to improve musculoskeletal, neurologic, and cosmetic conditions. There are few clinical studies evaluating the efficacy and safety of mesotherapy in any form. This study evaluates the histologic and clinical changes associated with one of the simplest formulations of mesotheraphy commonly used for skin rejuvenation. Ten subjects underwent four sessions of mesotherapy involving multiple injections of a multivitamin and hyaluronic acid solution. Treatment was conducted at 4 monthly intervals. All subjects had pre- and post-treatment photographs and skin biopsies. Skin biopsies were evaluated with routine histology, mucin and elastin stains, and electron microscopy. Patient surveys were also evaluated. Evaluation of photographs at 0, 3, and 6 months revealed no significant clinical differences. Light microscopic examination of pre- and posttreatment specimens showed no significant changes. Electron microscopic analysis of collagen fibers measurements did show smaller diameter fibres posttreatment. No significant clinical or histologic changes were observed after multivitamin mesotherapy for skin rejuvenation. Multivitamin and hyaluronic acid solution facial mesotherapy does not appear to provide any significant benefit.

  1. Local texture measurements with the scanning electron microscope

    International Nuclear Information System (INIS)

    Gottstein, G.; Engler, O.

    1993-01-01

    Techniques for convenient measurement of the crystallographic orientation of small volumes in bulk samples by electron diffraction in the SEM are discussed. They make use of Selected Area Electron Channelling Patterns (SAECP) and Electron Back Scattering Patterns (EBSP). The principle of pattern formation as well as measuring and evaluation procedure are introduced. The methods offer a viable procedure for obtaining information on the spatial arrangement of orientations, i.e. on orientation topography. Thus, they provide a new level of information on crystallographic texture. An application of the techniques for local texture measurements is demonstrated by an example, namely for investigation of considering the recrystallization behaviour of binary Al-1.3% Mn with large precipitates. Finally, further developments of the EBSP technique are addressed. (orig.)

  2. Angularly-selective transmission imaging in a scanning electron microscope.

    Science.gov (United States)

    Holm, Jason; Keller, Robert R

    2016-08-01

    This work presents recent advances in transmission scanning electron microscopy (t-SEM) imaging control capabilities. A modular aperture system and a cantilever-style sample holder that enable comprehensive angular selectivity of forward-scattered electrons are described. When combined with a commercially available solid-state transmission detector having only basic bright-field and dark-field imaging capabilities, the advances described here enable numerous transmission imaging modes. Several examples are provided that demonstrate how contrast arising from diffraction to mass-thickness can be obtained. Unanticipated image contrast at some imaging conditions is also observed and addressed. Published by Elsevier B.V.

  3. Catalysts under Controlled Atmospheres in the Transmission Electron Microscope

    DEFF Research Database (Denmark)

    Hansen, Thomas Willum; Wagner, Jakob Birkedal

    2014-01-01

    of resolution. Using suitably clean gases, modified pumping schemes, and short pathways through dense gas regions, these issues are now circumvented. Here we provide an account of best practice using environmental transmission electron microscopy on catalytic systems illustrated using select examples from......Over time, there has been an increasing interest in observing catalysts in their operating environment at high spatial resolution and ultimately to determine the structure of a catalytically active surface. One tool with the potential to do exactly this in direct space is the transmission electron...

  4. Design of a cathodoluminescence image generator using a Raspberry Pi coupled to a scanning electron microscope

    Science.gov (United States)

    Benítez, Alfredo; Santiago, Ulises; Sanchez, John E.; Ponce, Arturo

    2018-01-01

    In this work, an innovative cathodoluminescence (CL) system is coupled to a scanning electron microscope and synchronized with a Raspberry Pi computer integrated with an innovative processing signal. The post-processing signal is based on a Python algorithm that correlates the CL and secondary electron (SE) images with a precise dwell time correction. For CL imaging, the emission signal is collected through an optical fiber and transduced to an electrical signal via a photomultiplier tube (PMT). CL Images are registered in a panchromatic mode and can be filtered using a monochromator connected between the optical fiber and the PMT to produce monochromatic CL images. The designed system has been employed to study ZnO samples prepared by electrical arc discharge and microwave methods. CL images are compared with SE images and chemical elemental mapping images to correlate the emission regions of the sample.

  5. Wave Optical Calculation of Probe Size in Low Energy Scanning Electron Microscope

    Czech Academy of Sciences Publication Activity Database

    Radlička, Tomáš

    2015-01-01

    Roč. 21, S4 (2015), s. 212-217 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : scanning electron microscope * optical calculation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  6. Thin-film thickness measurement using x-ray peak ratioing in the scanning electron microscope

    International Nuclear Information System (INIS)

    Elliott, N.E.; Anderson, W.E.; Archuleta, T.A.; Stupin, D.M.

    1981-01-01

    The procedure used to measure laser target film thickness using a scanning electron microscope is summarized. This method is generally applicable to any coating on any substrate as long as the electron energy is sufficient to penetrate the coating and the substrate produces an x-ray signal which can pass back through the coating and be detected

  7. Removal of Vesicle Structures from Transmission Electron Microscope Images

    DEFF Research Database (Denmark)

    Jensen, Katrine Hommelhoff; Sigworth, Fred; Brandt, Sami Sebastian

    2015-01-01

    In this paper, we address the problem of imaging membrane proteins for single-particle cryo-electron microscopy reconstruction of the isolated protein structure. More precisely, we propose a method for learning and removing the interfering vesicle signals from the micrograph, prior to reconstruct...

  8. Examination of Graphene in a Scanning Low Energy Electron Microscope

    Czech Academy of Sciences Publication Activity Database

    Müllerová, Ilona; Mikmeková, Eliška; Frank, Luděk

    2015-01-01

    Roč. 21, S3 (2015), s. 29-30 ISSN 1431-9276 R&D Projects: GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : graphene * LEEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.730, year: 2015

  9. Progress in x-ray microanalysis in the analytical electron microscope

    International Nuclear Information System (INIS)

    Williams, D.B.

    1987-01-01

    Analytical electron microscopes (AEM) consisting of x-ray energy dispersive spectrometers (EDS) interfaced to scanning transmission electron microscopes have been available for more than a decade. During that time, progress towards reaching the fundamental limits of the technique has been slow. The progress of x-ray microanalysis in AEM is examined in terms of x-ray detector technology; the EDS/AEM interface; accuracy of microanalysis; and spatial resolution and detectability limits. X-ray microanalysis in the AEM has substantial room for improvement in terms of the interface between the detector and the microscope. Advances in microscope design and software should permit 10nm resolution with detectability limits approaching 0.01wt percent. 16 refs., 2 figs., 1 tab

  10. A Simple Metric for Determining Resolution in Optical, Ion, and Electron Microscope Images.

    Science.gov (United States)

    Curtin, Alexandra E; Skinner, Ryan; Sanders, Aric W

    2015-06-01

    A resolution metric intended for resolution analysis of arbitrary spatially calibrated images is presented. By fitting a simple sigmoidal function to pixel intensities across slices of an image taken perpendicular to light-dark edges, the mean distance over which the light-dark transition occurs can be determined. A fixed multiple of this characteristic distance is then reported as the image resolution. The prefactor is determined by analysis of scanning transmission electron microscope high-angle annular dark field images of Si. This metric has been applied to optical, scanning electron microscope, and helium ion microscope images. This method provides quantitative feedback about image resolution, independent of the tool on which the data were collected. In addition, our analysis provides a nonarbitrary and self-consistent framework that any end user can utilize to evaluate the resolution of multiple microscopes from any vendor using the same metric.

  11. Design of Pixellated CMOS Photon Detector for Secondary Electron Detection in the Scanning Electron Microscope

    Directory of Open Access Journals (Sweden)

    Joon Huang Chuah

    2011-01-01

    Full Text Available This paper presents a novel method of detecting secondary electrons generated in the scanning electron microscope (SEM. The method suggests that the photomultiplier tube (PMT, traditionally used in the Everhart-Thornley (ET detector, is to be replaced with a configurable multipixel solid-state photon detector offering the advantages of smaller dimension, lower supply voltage and power requirements, and potentially cheaper product cost. The design of the proposed detector has been implemented using a standard 0.35 μm CMOS technology with optical enhancement. This microchip comprises main circuit constituents of an array of photodiodes connecting to respective noise-optimised transimpedance amplifiers (TIAs, a selector-combiner (SC circuit, and a postamplifier (PA. The design possesses the capability of detecting photons with low input optical power in the range of 1 nW with 100 μm × 100 μm sized photodiodes and achieves a total amplification of 180 dBΩ at the output.

  12. The Physical Characterization of Liposome Salicylic Acid Using Transmission Electron Microscope

    International Nuclear Information System (INIS)

    Elman Panjaitan

    2008-01-01

    The physical characterization of liposome, formulated from salicylic acid using thin film hydration methods with cholesterol and soybean lecithin, has been done. The formula was characterized by optical microscopes and Transmission Electron Microscope (TEM). The observation result shows that the salicylic acid can be formulated to liposomes. Soybean lecithin combined with cholesterol (600 mg : 20 mg) was the best formula and the liposome was spherical vesicle like with dimension about 70 nm unit 800 nm. (author)

  13. Some applications of the high voltage electron microscope in physical metallurgy

    International Nuclear Information System (INIS)

    Regnier, P.; Thomas de Montpreville, C.

    1976-01-01

    The high voltage electron microscope (HVEM) is a microscope with a much higher penetration than the usual ones, as well as being a remarkable irradiation machine. The possible applications of the HVEM related to its advantages over the conventional microscopes are first discussed. The simultaneous use of the HVEM as an irradiation machine and an observation tool is then discussed, experiments carried in the laboratory being referred to. The last use of the HVEM makes it an irreplaceable tool for continuously following the clustering of irradiation defects [fr

  14. Electron magnetic chiral dichroism in CrO2 thin films using monochromatic probe illumination in a transmission electron microscope

    International Nuclear Information System (INIS)

    Loukya, B.; Zhang, X.; Gupta, A.; Datta, R.

    2012-01-01

    Electron magnetic chiral dichroism (EMCD) has been studied in CrO 2 thin films (with (100) and (110) growth orientations on TiO 2 substrates) using a gun monochromator in an aberration corrected transmission electron microscope operating at 300 kV. Excellent signal-to-noise ratio is obtained at spatial resolution ∼10 nm using a monochromatic probe as compared to conventional parallel illumination, large area convergent beam electron diffraction and scanning transmission electron microscopy techniques of EMCD. Relatively rapid exposure using mono probe illumination enables collection of EMCD spectra in total of 8–9 min in energy filtered imaging mode for a given Cr L 2,3 energy scan (energy range ∼35 eV). We compared the EMCD signal obtained by extracting the Cr L 2,3 spectra under three beam diffraction geometry of two different reciprocal vectors (namely g=110 and 200) and found that the g=200 vector enables acquisition of excellent EMCD signal from relatively thicker specimen area due to the associated larger extinction distance. Orbital to spin moment ratio has been calculated using EMCD sum rules for 3d elements and dichroic spectral features associated with CrO 2 are compared and discussed with XMCD theoretical spectra. - Highlights: ► Electron magnetic circular dichroism (EMCD) of CrO 2 thin film with two different orientations. ► Improved EMCD signal with Gun monochromator illumination. ► Improved EMCD signal with higher g vector.

  15. On the threshold conditions for electron beam damage of asbestos amosite fibers in the transmission electron microscope (TEM).

    Science.gov (United States)

    Martin, Joannie; Beauparlant, Martin; Sauvé, Sébastien; L'Espérance, Gilles

    2016-12-01

    Asbestos amosite fibers were investigated to evaluate the damage caused by a transmission electron microscope (TEM) electron beam. Since elemental x-ray intensity ratios obtained by energy dispersive x-ray spectroscopy (EDS) are commonly used for asbestos identification, the impact of beam damage on these ratios was evaluated. It was determined that the magnesium/silicon ratio best represented the damage caused to the fiber. Various tests showed that most fibers have a current density threshold above which the chemical composition of the fiber is modified. The value of this threshold current density varied depending on the fiber, regardless of fiber diameter, and in some cases could not be determined. The existence of a threshold electron dose was also demonstrated. This value was dependent on the current density used and can be increased by providing a recovery period between exposures to the electron beam. This study also established that the electron beam current is directly related to the damage rate above a current density of 165 A/cm 2 . The large number of different results obtained suggest, that in order to ensure that the amosite fibers are not damaged, analysis should be conducted below a current density of 100 A/cm 2 .

  16. Precision crystal alignment for high-resolution electron microscope imaging

    International Nuclear Information System (INIS)

    Wood, G.J.; Beeching, M.J.

    1990-01-01

    One of the more difficult tasks involved in obtaining quality high-resolution electron micrographs is the precise alignment of a specimen into the required zone. The current accepted procedure, which involves changing to diffraction mode and searching for symmetric point diffraction pattern, is insensitive to small amounts of misalignment and at best qualitative. On-line analysis of the fourier space representation of the image, both for determining and correcting crystal tilt, is investigated. 8 refs., 42 figs

  17. Practical Use of Scanning Low Energy Electron Microscope (SLEEM)

    Czech Academy of Sciences Publication Activity Database

    Müllerová, Ilona; Mikmeková, Eliška; Mikmeková, Šárka; Konvalina, Ivo; Frank, Luděk

    2016-01-01

    Roč. 22, S3 (2016), s. 1650-1651 ISSN 1431-9276 R&D Projects: GA TA ČR(CZ) TE01020118; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : scanning low energy * SLEEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.891, year: 2016

  18. Thinning of specimens for examination under the electron microscope

    International Nuclear Information System (INIS)

    Franks, J.

    1982-01-01

    Heretofore specimens have been thinned to penetration for examination by electron microscopy techniques, by ion erosion techniques. A more rapid technique is disclosed employing a beam or beams comprised solely of neutral particles. In tests carried out using this technique the sputtering rate from a sample specimen has been shown to be several percentages greater using a neutral source than from an ion source with the same flux density. (author)

  19. Development of an environmental high-voltage electron microscope for reaction science.

    Science.gov (United States)

    Tanaka, Nobuo; Usukura, Jiro; Kusunoki, Michiko; Saito, Yahachi; Sasaki, Katuhiro; Tanji, Takayoshi; Muto, Shunsuke; Arai, Shigeo

    2013-02-01

    Environmental transmission electron microscopy and ultra-high resolution electron microscopic observation using aberration correctors have recently emerged as topics of great interest. The former method is an extension of the so-called in situ electron microscopy that has been performed since the 1970s. Current research in this area has been focusing on dynamic observation with atomic resolution under gaseous atmospheres and in liquids. Since 2007, Nagoya University has been developing a new 1-MV high voltage (scanning) transmission electron microscope that can be used to observe nanomaterials under conditions that include the presence of gases, liquids and illuminating lights, and it can be also used to perform mechanical operations to nanometre-sized areas as well as electron tomography and elemental analysis by electron energy loss spectroscopy. The new instrument has been used to image and analyse various types of samples including biological ones.

  20. Contrast and decay of cathodoluminescence from phosphor particles in a scanning electron microscope.

    Science.gov (United States)

    den Engelsen, Daniel; Harris, Paul G; Ireland, Terry G; Fern, George R; Silver, Jack

    2015-10-01

    Cathodoluminescence (CL) studies are reported on phosphors in a field emission scanning electron microscope (FESEM). ZnO: Zn and other luminescent powders manifest a bright ring around the periphery of the particles: this ring enhances the contrast. Additionally, particles resting on top of others are substantially brighter than underlying ones. These phenomena are explained in terms of the combined effects of electrons backscattered out of the particles, together with light absorption by the substrate. The contrast is found to be a function of the particle size and the energy of the primary electrons. Some phosphor materials exhibit a pronounced comet-like structure at high scan rates in a CL-image, because the particle continues to emit light after the electron beam has moved to a position without phosphor material. Image analysis has been used to study the loss of brightness along the tail and hence to determine the decay time of the materials. The effect of phosphor saturation on the determination of decay times by CL-microscopy was also investigated. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. High-resolution imaging in the scanning transmission electron microscope

    International Nuclear Information System (INIS)

    Pennycook, S.J.; Jesson, D.E.

    1992-03-01

    The high-resolution imaging of crystalline materials in the scanning transmission electron microscopy (STEM) is reviewed with particular emphasis on the conditions under which an incoherent image can be obtained. It is shown that a high-angle annular detector can be used to break the coherence of the imaging process, in the transverse plane through the geometry of the detector, or in three dimensions if multiphonon diffuse scattering is detected. In the latter case, each atom can be treated as a highly independent source of high-angle scattering. The most effective fast electron states are therefore tightly bound s-type Bloch states. Furthermore, they add constructively for each incident angle in the coherent STEM probe, so that s states are responsible for practically the entire image contrast. Dynamical effects are largely removed, and almost perfect incoherent imaging is achieved. s states are relatively insensitive to neighboring strings, so that incoherent imaging is maintained for superlattice and interfaces, and supercell calculations are unnecessary. With an optimum probe profile, the incoherent image represents a direct image of the crystal projection, with compositional sensitivity built in through the strong dependence of the scattering cross sections on atomic number Z

  2. Three-dimensional optical transfer functions in the aberration-corrected scanning transmission electron microscope.

    Science.gov (United States)

    Jones, L; Nellist, P D

    2014-05-01

    In the scanning transmission electron microscope, hardware aberration correctors can now correct for the positive spherical aberration of round electron lenses. These correctors make use of nonround optics such as hexapoles or octupoles, leading to the limiting aberrations often being of a nonround type. Here we explore the effect of a number of potential limiting aberrations on the imaging performance of the scanning transmission electron microscope through their resulting optical transfer functions. In particular, the response of the optical transfer function to changes in defocus are examined, given that this is the final aberration to be tuned just before image acquisition. The resulting three-dimensional optical transfer functions also allow an assessment of the performance of a system for focal-series experiments or optical sectioning applications. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  3. Dual ion beam irradiation system for in situ observation with electron microscope

    International Nuclear Information System (INIS)

    Tsukamoto, Tetuo; Hojou, Kiiti; Furuno, Sigemi; Otsu, Hitosi; Izui, Kazuhiko.

    1993-01-01

    We have developed a new in situ observation system for dynamic processes under dual ion beam irradiation. The system consists of a modified 400 keV analytical electron microscope (JEOL, JEM-4000FX) and two 40 kV ion beam accelerators. This system allows evaluation of microscopic changes of structure and chemical bonding state of materials in the dynamic processes under two kinds of ion beam irradiations, that is required for the simulation test of the first wall of nuclear fusion reactors onto which He + , H + , and H 2 + ions are irradiated simultaneously. These two ion accelerators were equipped symmetrically both sides of the electron microscope and individually controlled. Each ion beam extracted from a duo-plasmatron ion gun is bent downward by an angle of 30deg with a mass-separating magnet, and introduced into specimen chamber of the electron microscope. Inside the specimen chamber the beam is deflected again by an angle of 30deg with an electrostatic prism so as to be incident on the specimen surface. Finally, two ion beams from both side are incident on the specimen surface at an angle of 60deg. The maximum ion current density of helium is more than 250μA/cm 2 at the specimen at an ion energy of 17 keV. Images of the electron microscope during dual ion beam irradiation are observed through a TV camera and recorded with a VTR. (author)

  4. Transmission electron microscope cells for use with liquid samples

    Science.gov (United States)

    Khalid, Waqas; Alivisatos, Paul A.; Zettl, Alexander K.

    2016-08-09

    This disclosure provides systems, methods, and devices related to transmission electron microscopy cells for use with liquids. In one aspect a device includes a substrate, a first graphene layer, and a second graphene layer. The substrate has a first surface and a second surface. The first surface defines a first channel, a second channel, and an outlet channel. The first channel and the second channel are joined to the outlet channel. The outlet channel defines a viewport region forming a though hole in the substrate. The first graphene layer overlays the first surface of the substrate, including an interior area of the first channel, the second channel, and the outlet channel. The second graphene layer overlays the first surface of the substrate, including open regions defined by the first channel, the second channel, and the outlet channel.

  5. Novel low-dose imaging technique for characterizing atomic structures through scanning transmission electron microscope

    Science.gov (United States)

    Su, Chia-Ping; Syu, Wei-Jhe; Hsiao, Chien-Nan; Lai, Ping-Shan; Chen, Chien-Chun

    2017-08-01

    To investigate dislocations or heterostructures across interfaces is now of great interest to condensed matter and materials scientists. With the advances in aberration-corrected electron optics, the scanning transmission electron microscope has demonstrated its excellent capability of characterizing atomic structures within nanomaterials, and well-resolved atomic-resolution images can be obtained through long-exposure data acquisition. However, the sample drifting, carbon contamination, and radiation damage hinder further analysis, such as deriving three-dimensional (3D) structures from a series of images. In this study, a method for obtaining atomic-resolution images with significantly reduced exposure time was developed, using which an original high-resolution image with approximately one tenth the electron dose can be obtained by combining a fast-scan high-magnification image and a slow-scan low-magnification image. The feasibility of obtaining 3D atomic structures using the proposed approach was demonstrated through multislice simulation. Finally, the feasibility and accuracy of image restoration were experimentally verified. This general method cannot only apply to electron microscopy but also benefit to image radiation-sensitive materials using various light sources.

  6. Modification of a scanning electron microscope to produce Smith-Purcell radiation

    International Nuclear Information System (INIS)

    Kapp, Oscar H.; Sun, Yin-e; Kim, Kwang-Je; Crewe, Albert V.

    2004-01-01

    We have modified a scanning electron microscope (SEM) in an attempt to produce a miniature free electron laser that can produce radiation in the far infrared region, which is difficult to obtain otherwise. This device is similar to the instrument studied by the Dartmouth group and functions on the basic principles first described by Smith and Purcell. The electron beam of the SEM is passed over a metal grating and should be capable of producing photons either in the spontaneous emission regime or in the superradiance regime if the electron beam is sufficiently bright. The instrument is capable of being continuously tuned by virtue of the period of the metal grating and the choice of accelerating voltage. The emitted Smith-Purcell photons exit the instrument via a polyethylene window and are detected by an infrared bolometer. Although we have obtained power levels exceeding nanowatts in the spontaneous emission regime, we have thus far not been able to detect a clear example of superradiance

  7. A video-amplifier device for the transmission-type electron microscope ELMISCOP I of Siemens

    International Nuclear Information System (INIS)

    Groboth, G.; Hoerl, E.M.

    1975-01-01

    In order to get a visual image of the sample at the final screen of a transmission-type electron microscope and to keep at the same time the sample at low temperature a video-amplifier device has been developed by the authors. Details about its design and the necessary reconstruction of the electron microscope equipment are given. The beam current density at the transparent screen is reduced to 10 -12 -10 -13 A.cm -2 . Moreover the costs of this video-amplifier device are lower than those available. (CR)

  8. Scanning tunnelling microscope imaging of nanoscale electron density gradients on the surface of GaAs

    International Nuclear Information System (INIS)

    Hamilton, B; Jacobs, J; Missous, M

    2003-01-01

    This paper is concerned with the scanning tunnelling microscope tunnelling conditions needed to produce constant current images dominated either by surface topology or by electronic effects. A model experimental structure was produced by cleaving a GaAs multiδ-doped layer in UHV and so projecting a spatially varying electron gas density onto the (110) surface. This cross sectional electron density varies on a nanometre scale in the [100] growth direction. The electronic structure and tunnelling properties of this system were modelled, and the tunnelling conditions favouring sensitivity to the surface electron gas density determined

  9. Nanoscale Energy-Filtered Scanning Confocal Electron Microscopy Using a Double-Aberration-Corrected Transmission Electron Microscope

    International Nuclear Information System (INIS)

    Wang Peng; Behan, Gavin; Kirkland, Angus I.; Nellist, Peter D.; Takeguchi, Masaki; Hashimoto, Ayako; Mitsuishi, Kazutaka; Shimojo, Masayuki

    2010-01-01

    We demonstrate that a transmission electron microscope fitted with two spherical-aberration correctors can be operated as an energy-filtered scanning confocal electron microscope. A method for establishing this mode is described and initial results showing 3D chemical mapping with nanoscale sensitivity to height and thickness changes in a carbon film are presented. Importantly, uncorrected chromatic aberration does not limit the depth resolution of this technique and moreover performs an energy-filtering role, which is explained in terms of a combined depth and energy-loss response function.

  10. An investigation of the electron irradiation of graphite in a helium atmosphere using a modified electron microscope

    International Nuclear Information System (INIS)

    Burden, A.P.; Hutchison, J.L.

    1997-01-01

    The behaviour of graphite particles immersed in helium gas and irradiated with an electron-beam has been investigated. Because this treatment was performed in a modified high resolution transmission electron microscope, the rapid morphological and microstructural changes that occurred could be directly observed. The results have implications for future controlled environment microscopy of carbonaceous materials and the characterisation of such microscopes. It is also shown that the processes can provide insight into ion-irradiation induced damage of graphite and the mechanism of fullerene generation. (Author)

  11. Electron Microscopic Visualization of Protein Assemblies on Flattened DNA Origami.

    Science.gov (United States)

    Mallik, Leena; Dhakal, Soma; Nichols, Joseph; Mahoney, Jacob; Dosey, Anne M; Jiang, Shuoxing; Sunahara, Roger K; Skiniotis, Georgios; Walter, Nils G

    2015-07-28

    DNA provides an ideal substrate for the engineering of versatile nanostructures due to its reliable Watson-Crick base pairing and well-characterized conformation. One of the most promising applications of DNA nanostructures arises from the site-directed spatial arrangement with nanometer precision of guest components such as proteins, metal nanoparticles, and small molecules. Two-dimensional DNA origami architectures, in particular, offer a simple design, high yield of assembly, and large surface area for use as a nanoplatform. However, such single-layer DNA origami were recently found to be structurally polymorphous due to their high flexibility, leading to the development of conformationally restrained multilayered origami that lack some of the advantages of the single-layer designs. Here we monitored single-layer DNA origami by transmission electron microscopy (EM) and discovered that their conformational heterogeneity is dramatically reduced in the presence of a low concentration of dimethyl sulfoxide, allowing for an efficient flattening onto the carbon support of an EM grid. We further demonstrated that streptavidin and a biotinylated target protein (cocaine esterase, CocE) can be captured at predesignated sites on these flattened origami while maintaining their functional integrity. Our demonstration that protein assemblies can be constructed with high spatial precision (within ∼2 nm of their predicted position on the platforms) by using strategically flattened single-layer origami paves the way for exploiting well-defined guest molecule assemblies for biochemistry and nanotechnology applications.

  12. Electron microscopic examination of uncultured soil-dwelling bacteria.

    Science.gov (United States)

    Amako, Kazunobu; Takade, Akemi; Taniai, Hiroaki; Yoshida, Shin-ichi

    2008-05-01

    Bacteria living in soil collected from a rice paddy in Fukuoka, Japan, were examined by electron microscopy using a freeze-substitution fixation method. Most of the observed bacteria could be categorized, based on the structure of the cell envelope and overall morphology, into one of five groups: (i) bacterial spore; (ii) Gram-positive type; (iii) Gram-negative type; (iv) Mycobacterium like; and (v) Archaea like. However, a few of the bacteria could not be readily categorized into one of these groups because they had unique cell wall structures, basically resembling those of Gram-negative bacteria, but with the layer corresponding to the peptidoglycan layer in Gram-negative bacteria being extremely thick, like that of the cortex of a bacterial spore. The characteristic morphological features found in many of these uncultured, soil-dwelling cells were the nucleoid being in a condensed state and the cytoplasm being shrunken. We were able to produce similar morphologies in vitro using a Salmonella sp. by culturing under low-temperature, low-nutrient conditions, similar to those found in some natural environments. These unusual morphologies are therefore hypothesized to be characteristic of bacteria in resting or dormant stages.

  13. In situ fatigue loading stage inside scanning electron microscope

    Science.gov (United States)

    Telesman, Jack; Kantzos, Peter; Brewer, David

    1988-01-01

    A fatigue loading stage inside a scanning electron microscopy (SEM) was developed. The stage allows dynamic and static high-magnification and high-resolution viewing of the fatigue crack initiation and crack propagation processes. The loading stage is controlled by a closed-loop servohydraulic system. Maximum load is 1000 lb (4450 N) with test frequencies ranging up to 30 Hz. The stage accommodates specimens up to 2 inches (50 mm) in length and tolerates substantial specimen translation to view the propagating crack. At room temperature, acceptable working resolution is obtainable for magnifications ranging up to 10,000X. The system is equipped with a high-temperature setup designed for temperatures up to 2000 F (1100 C). The signal can be videotaped for further analysis of the pertinent fatigue damage mechanisms. The design allows for quick and easy interchange and conversion of the SEM from a loading stage configuration to its normal operational configuration and vice versa. Tests are performed entirely in the in-situ mode. In contrast to other designs, the NASA design has greatly extended the life of the loading stage by not exposing the bellows to cyclic loading. The loading stage was used to investigate the fatigue crack growth mechanisms in the (100)-oriented PWA 1480 single-crystal, nickel-based supperalloy. The high-magnification observations revealed the details of the crack growth processes.

  14. Classification of heterogeneous electron microscopic projections into homogeneous subsets

    International Nuclear Information System (INIS)

    Herman, G.T.; Kalinowski, M.

    2008-01-01

    The co-existence of different states of a macromolecular complex in samples used by three-dimensional electron microscopy (3D-EM) constitutes a serious challenge. The single particle method applied directly to such heterogeneous sets is unable to provide useful information about the encountered conformational diversity and produces reconstructions with severely reduced resolution. One approach to solving this problem is to partition heterogeneous projection set into homogeneous components and apply existing reconstruction techniques to each of them. Due to the nature of the projection images and the high noise level present in them, this classification task is difficult. A method is presented to achieve the desired classification by using a novel image similarity measure and solving the corresponding optimization problem. Unlike the majority of competing approaches, the presented method employs unsupervised classification (it does not require any prior knowledge about the objects being classified) and does not involve a 3D reconstruction procedure. We demonstrate a fast implementation of this method, capable of classifying projection sets that originate from 3D-EM. The method's performance is evaluated on synthetically generated data sets produced by projecting 3D objects that resemble biological structures

  15. Design for an aberration corrected scanning electron microscope using miniature electron mirrors.

    Science.gov (United States)

    Dohi, Hideto; Kruit, Pieter

    2018-06-01

    Resolution of scanning electron microscopes (SEMs) is determined by aberrations of the objective lens. It is well known that both spherical and chromatic aberrations can be compensated by placing a 90-degree bending magnet and an electron mirror in the beam path before the objective lens. Nevertheless, this approach has not led to wide use of these aberration correctors, partly because aberrations of the bending magnet can be a serious problem. A mirror corrector with two mirrors placed perpendicularly to the optic axis of an SEM and facing each other is proposed. As a result, only small-angle magnetic deflection is necessary to guide the electron beam around the top mirror to the bottom mirror and around the bottom mirror to the objective lens. The deflection angle, in the order of 50 mrad, is sufficiently small to avoid deflection aberrations. In addition, lateral dispersion at the sample plane can be avoided by making the deflection fields symmetric. Such a corrector system is only possible if the incoming beam can pass the top mirror at a distance in the order of millimeters, without being disturbed by the electric fields of electrodes of the mirror. It is proposed that condition can be satisfied with micro-scale electron optical elements fabricated by using MEMS technology. In the proposed corrector system, the micro-mirrors have to provide the exact negative spherical and chromatic aberrations for correcting the aberration of the objective lens. This exact tuning is accomplished by variable magnification between the micro-mirrors and the objective lens using an additional transfer lens. Extensive optical calculations are reported. Aberrations of the micro-mirrors were analyzed by numerical calculation. Dispersion and aberrations of the deflectors were calculated by using an analytical field model. Combination aberrations caused by the off-axis position of dispersive rays in the mirrors and objective lens were also analyzed. It is concluded that the proposed

  16. Scanning electron microscope investigations of nuclear pore filters in polyester foils

    International Nuclear Information System (INIS)

    Hopfe, J.

    1980-01-01

    In order to understand and characterize the action of nuclear pore filters it is necessary to know their surface, as well as their bulk, structure. In the present work, investigations of the surface structure (pore size, pore density, pore distribution) and of the pore geometry, especially in the bulk of the filters, are carried out by scanning electron microscopic (SEM) studies. The preparation technique needed is liquid-nitrogen freeze-fracturing followed by a conductive-coating step. Nuclear pore filters studied in this paper were produced by a track etching technique. Laboratory specimens were obtained by bombarding 10 μm thick polyester foils with Xe-ions and a subsequent etching with 20% NaOH. The SEM results are shown and discussed. (author)

  17. Effects of electrohydraulic extracorporeal shock wave lithotripsy on submandibular gland in the rat: electron microscopic evaluation.

    Science.gov (United States)

    Bayar, Nuray; Kaymaz, F Figen; Apan, Alpaslan; Yilmaz, Erdal; Cakar, A Nur

    2002-05-15

    Extracorporeal shockwave lithotripsy (ESWL) has been applied in sialolithiasis as a new treatment modality. The aim of this experimental study is to investigate the local effects of electrohydraulic ESWL applied to the right submandibular gland of the rats. This prospective study was conveyed in four groups; groups I, II, III and IV; each group consisting of 20, 20, 18 and 9 rats, respectively, with a randomized distribution. Groups I, II, III and IV received 250, 500, 1000 and 2000 shock waves at 14-16 kV (average 15.1 kV), respectively, to the right submandibular glands on the 0th day. In groups I, II, III, right submandibular glands of the rats were removed on the 0th, 1st, 7th and 15th days; in group IV, this procedure could be managed only on the 0th and 7th days. Light and electron microscopic evaluation were assessed. Using the light microscopic changes, severity of damage score of the glands (SDS) was found. Statistical analysis was done using SDSs. Light and electron microscopic observations have shown that the damage produced by the shock waves were confined to focal areas in the acinar cells (AC), granulated convoluted tubule (GCT) cells and blood vessels at all doses applied. Vacuolization in the cytoplasms of the AC and GCT cells, disintegration of membranes, alteration in the cytoplasmic organization, swelling of the mitochondria and loss of the features were observed on electron microscopy. Increase in the secretion rate; stasis and dilatation in the blood vessels; blebbing and loss of features in the cytoplasm of the endothelial cells were observed. According to the result of the statistical analysis using SDSs; at 250 shock wave dose, a statistically significant difference between the SDSs of the days (0th, 1st, 7th and 15th) was found (Pwaves (Pwaves was found to have the lower value than the SDS at the 2000 shock wave. It was observed that produced damage was less prominent by small doses (250, 500 doses) initially (0th day). Electrohydraulic

  18. Light and scanning electron microscopic studies of Myxobolus indica n. sp. and a report of three Myxozoan (Myxosporea: Bivalvulida parasites of cultured ornamental goldfish, Carassius auratus L. for the first time in India

    Directory of Open Access Journals (Sweden)

    Mandira Saha

    2017-08-01

    Full Text Available The ornamental fish industry is an economically viable sector in India which suffers from different ectoparasitic infestations, including the myxozoan parasites. An icthyoparasitological survey of myxozoan infections in ornamental fish farms in India revealed the presence of four myxozoan parasites belonging to the family Myxobolidae, in the genera Myxobolus and Thelohanellus. The myxozoan spores were small to large, spherical to ellipsoidal in size. The plasmodia measured 0.5–3.0 mm in diameter with disporic pansporoblasts and mature spores. During the survey the authors identified for the first time in India, three previously described species, namely, M. mehlhorni, T. nikolskii and T. batae; and one new species M. indica n. sp., all infecting the ornamental goldfish, Carassius auratus. The present study thus reports a new host, and a new locality for T. batae and M. mehlhorni. The description of T. nikolskii is the first record found in India. The spore of M. indica n. sp. measures 5.8 ± 0.2 × 4.1 ± 0.5 μm in size, having two equal shaped pyriform polar capsules measuring 4.1 ± 0.4 × 2.7 ± 0.6 μm. The results from a combination of light and scanning electron microscopic observations along with a comparison with closely related species were incorporated here. Molecular data is needed to complete the description of the new species.

  19. Choice of operating voltage for a transmission electron microscope

    International Nuclear Information System (INIS)

    Egerton, R.F.

    2014-01-01

    An accelerating voltage of 100–300 kV remains a good choice for the majority of TEM or STEM specimens, avoiding the expense of high-voltage microscopy but providing the possibility of atomic resolution even in the absence of lens-aberration correction. For specimens thicker than a few tens of nm, the image intensity and scattering contrast are likely to be higher than at lower voltage, as is the visibility of ionization edges below 1000 eV (as required for EELS elemental analysis). In thick (>100 nm) specimens, higher voltage ensures less beam broadening and better spatial resolution for STEM imaging and EDX spectroscopy. Low-voltage (e.g. 30 kV) TEM or STEM is attractive for a very thin (e.g. 10 nm) specimen, as it provides higher scattering contrast and fewer problems for valence-excitation EELS. Specimens that are immune to radiolysis suffer knock-on damage at high current densities, and this form of radiation damage can be reduced or avoided by choosing a low accelerating voltage. Low-voltage STEM with an aberration-corrected objective lens (together with a high-angle dark-field detector and/or EELS) offers atomic resolution and elemental identification from very thin specimens. Conventional TEM can provide atomic resolution in low-voltage phase-contrast images but requires correction of chromatic aberration and preferably an electron-beam monochromator. Many non-conducting (e.g. organic) specimens damage easily by radiolysis and radiation damage then determines the TEM image resolution. For bright-field scattering contrast, low kV can provide slightly better dose-limited resolution if the specimen is very thin (a few nm) but considerably better resolution is possible from a thicker specimen, for which higher kV is required. Use of a phase plate in a conventional TEM offers the most dose-efficient way of achieving atomic resolution from beam-sensitive specimens. - Highlights: • 100–300 kV accelerating voltage is suitable for TEM specimens of typical

  20. X-ray spectrum determination of elements with low atomic number with use of electron microscope

    International Nuclear Information System (INIS)

    Smirnov, V.N.

    1982-01-01

    Separate assemblies of a commercial analytical electron microscope-microanalyzer EMMA-2 have been modified to study objects, containing elements with the atomic number Z=5-9, in particular: 1) the range of changing the accelerating voltages is expanded to be in the range of 25 down to 10 kV with 5 kV interval. 2) image intensifier using microchannel plate MKP-40-19 is applied; 3) for elements of carbon, oxygen, boron, nitrogen type a unit with flow-type proportional counter is used. The sensitivity of carbon- and oxygen determination in carbides and oxides is 0.15-0.3% at the measurement time of 100 s. Results of microanalysis of the particles of B 2 O 3 , Al 2 O 3 , SiO 2 , Fe 2 O 3 , Fe 3 C, WC for the contents of oxygen and carbon are presented

  1. Scanning electron microscopic observations of fibrous structure of cemento-dentinal junction in healthy teeth.

    Science.gov (United States)

    Pratebha, B; Jaikumar, N D; Sudhakar, R

    2014-01-01

    The cemento-dentinal junction (CDJ) is a structural and biologic link between cementum and dentin present in the roots of teeth. Conflicting reports about the origin, structure and composition of this layer are present in literature. The width of this junctional tissue is reported to be about 2-4 μm with adhesion of cementum and dentin by proteoglycans and by collagen fiber intermingling. The objective of this study is to observe and report the fibrous architecture of the CDJ of healthy tooth roots. A total of 15 healthy teeth samples were collected, sectioned into halves, demineralized in 5% ethylenediaminetetraacetic acid, processed using NaOH maceration technique and observed under a scanning electron microscope. The CDJ appeared to be a fibril poor groove with a width of 2-4 µm. Few areas of collagen fiber intermingling could be appreciated. A detailed observation of these tissues has been presented.

  2. Modeling of temperature profiles in an environmental transmission electron microscope using computational fluid dynamics

    DEFF Research Database (Denmark)

    Mortensen, Peter Mølgaard; Jensen, Anker Degn; Hansen, Thomas Willum

    2015-01-01

    The temperature and velocity field, pressure distribution, and the temperature variation across the sample region inside an environmental transmission electron microscope (ETEM) have been modeled by means of computational fluid dynamics (CFD). Heating the sample area by a furnace type TEM holder...... gives rise to temperature gradients over the sample area. Three major mechanisms have been identified with respect to heat transfer in the sample area: radiation from the grid, conduction in the grid, and conduction in the gas. A parameter sensitivity analysis showed that the sample temperature...... was affected by the conductivity of the gas, the emissivity of the sample grid, and the conductivity of the grid. Ideally the grid should be polished and made from a material with good conductivity, e.g. copper. With hydrogen gas, which has the highest conductivity of the gases studied, the temperature...

  3. Theoretical analysis of moiré fringe multiplication under a scanning electron microscope

    International Nuclear Information System (INIS)

    Li, Yanjie; Xie, Huimin; Chen, Pengwan; Zhang, Qingming

    2011-01-01

    In this study, theoretical analysis and experimental verification of fringe multiplication under a scanning electron microscope (SEM) are presented. Fringe multiplication can be realized by enhancing the magnification or the number of scanning lines under the SEM. A universal expression of the pitch of moiré fringes is deduced. To apply this method to deformation measurement, the calculation formulas of strain and displacement are derived. Compared to natural moiré, the displacement sensitivity is increased by fringe multiplication while the strain sensitivity may be retained or enhanced depending on the number of scanning lines used. The moiré patterns are formed by the interference of a 2000 lines mm −1 grating with the scanning lines of SEM, and the measured parameters of moiré fringes from experimental results agree well with theoretical analysis

  4. Flow visualization and velocity measurement in a small-scale open channel using an electron microscope

    International Nuclear Information System (INIS)

    Yasuda, K; Sogo, M; Iwamoto, Y

    2013-01-01

    The present note describes a method for use in conjunction with a scanning electron microscope (SEM) that has been developed to visualize a liquid flow under a high-level vacuum and to measure a velocity field in a small-scale flow through an open channel. In general, liquid cannot be observed via a SEM, because liquid evaporates under the high-vacuum environment of the SEM. As such, ionic liquid and room temperature molten salt having a vapor pressure of nearly zero is used in the present study. We use ionic liquid containing Au-coated tracer particles to visualize a small-scale flow under a SEM. Furthermore, the velocity distribution in the open channel is obtained by particle tracking velocimetry measurement and a parabolic profile is confirmed. (technical design note)

  5. Mite Biodiversity Under the Low Temperature Scanning Electron Microscope

    Science.gov (United States)

    To date, more than 55,000 mite species have been described and only a few of them have been studied. Some mites are adapted to live deep in soil, others in fresh or sea water, some are on plants, algae, fungi or animals, and others are able to survive in both extreme cold and hot temperatures. The...

  6. Dynamic Low-Vacuum Scanning Electron Microscope Freeze Drying Observation for Fresh Water Algae

    International Nuclear Information System (INIS)

    Mohsen, H.T.; Ghaly, W.A.; Zahran, N.F.; Helal, A.I.

    2010-01-01

    A new perpetration method for serving in dynamic examinations of the fresh water algae is developed in connection with the Low-Vacuum Scanning Electron Microscope (LV-SEM) freeze drying technique. Specimens are collected from fresh water of Ismailia channel then transferred directly to freeze by liquid nitrogen and dried in the chamber of the scanning electron microscope in the low vacuum mode. Scanning electron micrographs revealed that the drying method presented the microstructure of algae. Dehydration in a graded ethanol series is not necessary in the new method. Dried algae specimen is observed in SEM high vacuum mode after conductive coating at higher resolution. Low-vacuum SEM freeze drying technique is a simple, time-saving and reproducible method for scanning electron microscopy that is applicable to various aquatic microorganisms covered with soft tissues.

  7. Electron-microscopic investigations of dispersion-strengthened superalloys

    International Nuclear Information System (INIS)

    Schroeder, J.H.; Arzt, E.

    1988-01-01

    Oxide dispersion strengthened (ODS) superalloys possess a high creep strength up to temperatures above 1000 0 C. This is due to a fine dispersion of incoherent Y 2 O 3 particles in connection with a highly elongated grain structure. To investigate the production and properties of ODS alloys, the grain structure was studied and the shape and distribution of dispersoids were characterized after each of the various production steps. Because the interactions between lattice dislocations and dispersoids control the deformation behaviour at high temperatures, the dislocation-dispersoid configurations in crept specimens have been studied by a TEM stereo technique and under weak-beam conditions. It was possible to detect strain fields around the dispersoids using TEM. The results lead to an improved understanding of dispersion strengthening at high temperatures and provide guidelines for the optimum use of this strengthening mechanism. (orig.) [de

  8. APPLICATION OF SCANNING ELECTRON MICROSCOPE EQUIPPED WITH THE MICROANALYSIS SYSTEM FOR INVESTIGATION OF BRASS COVERING

    Directory of Open Access Journals (Sweden)

    T. P. Kurenkova

    2010-01-01

    Full Text Available The possibilities of application of scanning electronic microscope equipped with microanalysis system for investigation of the brass covering quality by slug for production of wire and metal cord particularly of change of copper concentration by covering thickness and slug perimeter, revealing of ?-phase allocation presence and character, determination of defect reasons, are shown.

  9. Practical application of HgI2 detectors to a space-flight scanning electron microscope

    Science.gov (United States)

    Bradley, J. G.; Conley, J. M.; Albee, A. L.; Iwanczyk, J. S.; Dabrowski, A. J.

    1989-01-01

    Mercuric iodide X-ray detectors have been undergoing tests in a prototype scanning electron microscope system being developed for unmanned space flight. The detector program addresses the issues of geometric configuration in the SEM, compact packaging that includes separate thermoelectric coolers for the detector and FET, X-ray transparent hermetic encapsulation and electrical contacts, and a clean vacuum environment.

  10. Characterization of calcium crystals in Abelia using x-ray diffraction and electron microscopes

    Science.gov (United States)

    Localization, chemical composition, and morphology of calcium crystals in leaves and stems of Abelia mosanensis and A. ×grandiflora were analyzed with a variable pressure scanning electron microscope (VP-SEM) equipped with an X-ray diffraction system, low temperature SEM (LT-SEM) and a transmission ...

  11. Minimal exposure technique in the Cambridge University 600kV high resolution electron microscope

    International Nuclear Information System (INIS)

    Fryer, J.R.; Cleaver, J.R.A.; Smith, D.J.

    1980-01-01

    Radiation damage due to the incident electron beam imposes a fundamental limitation on the information obtainable by electron microscopy about organic materials; it is desirable therefore that exposure of the specimen to the electron beam should be restricted to the actual period during which the image is being recorded. A description is given of methods employed in the observation of the organic aromatic hydrocarbons quaterrylene, ovalene and coronene with the Cambridge University 600kV high resolution electron microscope (HREM). In particular, the condenser-objective mode of operation of this microscope lends itself to the use of an area-defining aperture below the second condenser lens conjugate with the specimen. Furthermore, operation at the higher accelerating voltage of this instrument could be anticipated to reduce the rate of damage, depending on the dominant beam-specimen interaction, whilst the increased width of the first broad band of the contrast transfer function of this microscope at the optimum defocus may overcome the reported resolution limitation of current 100kV microscopes for the observation of related materials. (author)

  12. Theory of life time measurements with the scanning electron microscope: steady state

    NARCIS (Netherlands)

    Berz, F.; Kuiken, H.K.

    1976-01-01

    A theoretical steady state analysis is given of the scanning electron microscope method of measuring bulk life time in diodes, where the plane of the junction is perpendicular to the surface. The current in the junction is obtained as a function of the beam power, the beam penetration into the

  13. An ultrafast electron microscope gun driven by two-photon photoemission from a nanotip cathode

    International Nuclear Information System (INIS)

    Bormann, Reiner; Strauch, Stefanie; Schäfer, Sascha; Ropers, Claus

    2015-01-01

    We experimentally and numerically investigate the performance of an advanced ultrafast electron source, based on two-photon photoemission from a tungsten needle cathode incorporated in an electron microscope gun geometry. Emission properties are characterized as a function of the electrostatic gun settings, and operating conditions leading to laser-triggered electron beams of very low emittance (below 20 nm mrad) are identified. The results highlight the excellent suitability of optically driven nano-cathodes for the further development of ultrafast transmission electron microscopy

  14. A design for a subminiature, low energy scanning electron microscope with atomic resolution

    International Nuclear Information System (INIS)

    Eastham, D. A.; Edmondson, P.; Greene, S.; Donnelly, S.; Olsson, E.; Svensson, K.; Bleloch, A.

    2009-01-01

    We describe a type of scanning electron microscope that works by directly imaging the electron field-emission sites on a nanotip. Electrons are extracted from the nanotip through a nanoscale aperture, accelerated in a high electric field, and focused to a spot using a microscale Einzel lens. If the whole microscope (accelerating section and lens) and the focal length are both restricted in size to below 10 μm, then computer simulations show that the effects of aberration are extremely small and it is possible to have a system with approximately unit magnification at electron energies as low as 300 eV. Thus a typical emission site of 1 nm diameter will produce an image of the same size, and an atomic emission site will give a resolution of 0.1-0.2 nm (1-2 A). Also, because the beam is not allowed to expand beyond 100 nm in diameter, the depth of field is large and the contribution to the beam spot size from chromatic aberrations is less than 0.02 nm (0.2 A) for 500 eV electrons. Since it is now entirely possible to make stable atomic sized emitters (nanopyramids), it is expected that this instrument will have atomic resolution. Furthermore the brightness of the beam is determined only by the field emission and can be up to 1x10 6 times larger than in a typical (high energy) electron microscope. The advantages of this low energy, bright-beam electron microscope with atomic resolution are described and include the possibility of it being used to rapidly sequence the human genome from a single strand of DNA as well as being able to identify atomic species directly from the elastic scattering of electrons

  15. Tunneling rates in electron transport through double-barrier molecular junctions in a scanning tunneling microscope

    OpenAIRE

    Nazin, G. V.; Wu, S. W.; Ho, W.

    2005-01-01

    The scanning tunneling microscope enables atomic-scale measurements of electron transport through individual molecules. Copper phthalocyanine and magnesium porphine molecules adsorbed on a thin oxide film grown on the NiAl(110) surface were probed. The single-molecule junctions contained two tunneling barriers, vacuum gap, and oxide film. Differential conductance spectroscopy shows that electron transport occurs via vibronic states of the molecules. The intensity of spectral peaks correspondi...

  16. Transmission electron microscope interfaced with ion accelerators and its application to materials science

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Hiroaki; Naramoto, Hiroshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Hojou, Kiichi; Furuno, Shigemi; Tsukamoto, Tetsuo

    1997-03-01

    We have developed the transmission/analytical electron microscope interfaced with two sets of ion accelerators (TEM-Accelerators Facility) at JAERI-Takasaki. The facility is expected to provide quantitative insights into radiation effects, such as damage evolution, irradiation-induced phase transformation and their stability, through in-situ observation and analysis under ion and/or electron irradiation. The TEM-Accelerators Facility and its application to materials research are reviewed. (author)

  17. Optical and mechanical design for 1 nm resolution Auger spectroscopy in an electron microscope

    International Nuclear Information System (INIS)

    Bleeker, A.J.

    1991-01-01

    Detailed information about the atomic structure of surfaces and interfaces is vital for the progress in materials science and physics. One widely used surface sensitive technique is Auger spectroscopy (AS). This technique, in which the electron energy spectrum emerging from the sample is evaluated, gives information about the average elemental composition of the surface over a relative large surface area (>30nm). Electron microscopy (EM), on the other hand, is capable of producing surface structural, but no elemental, information with almost atomic resolution. EM and AS techniques have not been combined so far because of the different nature of the instrumentation used in both techniques. In AS instruments the sample is placed in an Ultra High Vacuum (UHV) system with a relatively large open space around the sample. In EM the sample is situated in the tight volume between the magnetic polepieces of the probe forming objective lens. The space around the sample is therefore tight. Furthermore the vacuum in most electron microscopes is not in UHV range. Radical mechanical changes to improve the vacuum are necessary to do AS in an electron microscope. Since the sample is immersed in the strong magnetic field of the objective lens the Auger electrons can not be extracted with conventional electrostatical methods. The only possibility to extract the Auger electrons is through the upper bore of the objective lens. However, this has large implications on the optical system of the microscope and requires a thorough investigation of the extraction of the Auger electrons. In this work it will be discussed how the surface sensitive AS can be combined with the high spatial resolution of the electron microscope in a practical instrument. (author). 102 refs.; 81 figs.; 4 tabs

  18. Irradiation damage of II-VI compounds in a high-voltage electron microscope

    International Nuclear Information System (INIS)

    Yoshiie, T.; Iwanaga, H.; Shibata, N.; Suzuki, K.; Ichihara, M.; Takeuchi, S.

    1983-01-01

    Dislocation loops produced by electron irradiation in a 1 MV electron microscope have been studied above room temperature for five II-VI compounds: CdS and ZnO, with the wurtzite structure, and CdTe, ZnSe and ZnS, with the zincblende structure. For all the crystals the density of loops decreased as the irradiation temperature increased, until no loops were produced above a certain temperature which varied from crystal to crystal. However, the loop density did not depend on the electron flux intensity, suggesting the heterogeneous nucleation at some impurity complex of equilibrium concentration. Diffraction contrast analyses showed that the loops are of interstitial type in each crystal, with Burgers vectors as follows: 1/2[0001] and 1/3 for wurtzite crystals, the density ratio of the former type to the latter being increased with increasing temperature; mostly 1/3 and a few 1/2 for zincblende crystals, the latter type being presumably formed as a result of unfaulting in the former. An effect of crystal polarity on the shape of the loops in zincblende crystals has been observed. (author)

  19. A scanning electron microscope method for automated, quantitative analysis of mineral matter in coal

    Energy Technology Data Exchange (ETDEWEB)

    Creelman, R.A.; Ward, C.R. [R.A. Creelman and Associates, Epping, NSW (Australia)

    1996-07-01

    Quantitative mineralogical analysis has been carried out in a series of nine coal samples from Australia, South Africa and China using a newly-developed automated image analysis system coupled to a scanning electron microscopy. The image analysis system (QEM{asterisk}SEM) gathers X-ray spectra and backscattered electron data from a number of points on a conventional grain-mount polished section under the SEM, and interprets the data from each point in mineralogical terms. The cumulative data in each case was integrated to provide a volumetric modal analysis of the species present in the coal samples, expressed as percentages of the respective coals` mineral matter. Comparison was made of the QEM{asterisk}SEM results to data obtained from the same samples using other methods of quantitative mineralogical analysis, namely X-ray diffraction of the low-temperature oxygen-plasma ash and normative calculation from the (high-temperature) ash analysis and carbonate CO{sub 2} data. Good agreement was obtained from all three methods for quartz in the coals, and also for most of the iron-bearing minerals. The correlation between results from the different methods was less strong, however, for individual clay minerals, or for minerals such as calcite, dolomite and phosphate species that made up only relatively small proportions of the mineral matter. The image analysis approach, using the electron microscope for mineralogical studies, has significant potential as a supplement to optical microscopy in quantitative coal characterisation. 36 refs., 3 figs., 4 tabs.

  20. Three-dimensional machining of carbon nanotube forests using water-assisted scanning electron microscope processing

    Energy Technology Data Exchange (ETDEWEB)

    Rajabifar, Bahram; Maschmann, Matthew R., E-mail: MaschmannM@missouri.edu [Department of Mechanical and Aerospace Engineering, University of Missouri, Columbia, Missouri 65211 (United States); Kim, Sanha; Hart, A. John [Department of Mechanical Engineering and Laboratory for Manufacturing and Productivity, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Slinker, Keith [Materials and Manufacturing Directorate, AFRL/RX, Air Force Research Lab, Ohio 45433 (United States); Universal Technology Corporation, Beavercreek, Ohio 45424 (United States); Ehlert, Gregory J. [Materials and Manufacturing Directorate, AFRL/RX, Air Force Research Lab, Ohio 45433 (United States)

    2015-10-05

    We demonstrate that vertically aligned carbon nanotubes (CNTs) can be precisely machined in a low pressure water vapor ambient using the electron beam of an environmental scanning electron microscope. The electron beam locally damages the irradiated regions of the CNT forest and also dissociates the water vapor molecules into reactive species including hydroxyl radicals. These species then locally oxidize the damaged region of the CNTs. The technique offers material removal capabilities ranging from selected CNTs to hundreds of cubic microns. We study how the material removal rate is influenced by the acceleration voltage, beam current, dwell time, operating pressure, and CNT orientation. Milled cuts with depths between 0–100 microns are generated, corresponding to a material removal rate of up to 20.1 μm{sup 3}/min. The technique produces little carbon residue and does not disturb the native morphology of the CNT network. Finally, we demonstrate direct machining of pyramidal surfaces and re-entrant cuts to create freestanding geometries.