WorldWideScience

Sample records for electromagnetic interference assessment

  1. Small Unmanned Aircraft Electromagnetic Interference (EMI) Initial Assessment

    Science.gov (United States)

    Jung, Jaewoo; Ippolito, Corey; Rogers, Christopher; Kerczewski, Robert; Downey, Alan; Matheou, Konstantin

    2018-01-01

    With many applications envisioned for small Unmanned Aircraft Systems (sUAS), and potentially millions of sUAS expected to be in operation in the future, the electromagnetic interference environment associated with the sUAS is of interest to understanding the potential performance impacts on the sUAS command and control communications link as well as the sUAS payload and payload links. As part of NASAâ€"TM"s UAS Traffic Management (UTM) Project, flight experiments are planned to characterize the RF environment at altitudes up to 400 ft to better understand how UTM command and control links can be expected to perform. The flight experiments will use an RF channel sensing payload attached to an sUAS. In terms of the payload being capable of measuring relatively low level signals at altitude, electromagnetic interference (EMI) emanating from the sUAS vehicle itself could potentially complicate the measurement process. For this reason, NASA was interested in measuring the EMI performance of the sUAS planned for these flight experiments, a DJI model S1000. The S1000 was thus measured in a controlled EMI test chamber at the NASA Ames Research Center. The S1000 is a carbon fiber based platform with eight rotors. As such, the EMI test results represent potential performance of a number of similar sUAS types. sUAS platforms significantly different from the S1000 may also require EMI testing, and the method employed for NASAâ€"TM"s S1000 EMI tests can be applied to other platforms. In this paper we describe the UTM project, the RF channel sensing payload, the EMI testing method and EMI test results for the S1000, and discuss the implications of these results.

  2. Electromagnetic interference: a radiant future!

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes

    2015-01-01

    Although Electromagnetic Interference and Electromagnetic Compatibility are well established domains, the introduction of new technologies results in new challenges. Changes in both measurement techniques, and technological trends resulting in new types of interference are described. These are the

  3. Electromagnetic Interference Assessment of CDMA and GSM Wireless Phones to Aircraft Navigation Radios

    Science.gov (United States)

    Ely, Jay J.; Nguyen, Truong X.; Koppen, Sandra V.; Salud, M. Theresa

    2002-01-01

    To address the concern for cellular phone electromagnetic interference (EMI) to aircraft radios, a radiated emission measurement process for CDMA (IS-95) and GSM (ETSI GSM 11.22) wireless handsets was developed. Spurious radiated emissions were efficiently characterized from devices tested in either a semi-anechoic or reverberation chamber, in terms of effective isotropic radiated power. Eight representative handsets (4 GSM, 4 CDMA) were commanded to operate while varying their radio transmitter parameters (power, modulation, etc.). This report provides a detailed description of the measurement process and resulting data, which may subsequently be used by others as a basis of consistent evaluation for cellular/PCS phones, Bluetooth, IEEE802.11b, IEEE802.11a, FRS/GMRS radios, and other portable transmitters. Aircraft interference path loss (IPL) and navigation radio interference threshold data from numerous reference documents, standards, and NASA partnerships were compiled. Using this data, a preliminary risk assessment is provided for CDMA and GSM wireless phone interference to aircraft localizer, Glideslope, VOR, and GPS radio receivers on typical transport airplanes. The report identifies where existing data for device emissions, IPL, and navigation radio interference thresholds needs to be extended for an accurate risk assessment for wireless transmitters in aircraft.

  4. A Systems-Based Risk Assessment Framework for Intentional Electromagnetic Interference (IEMI) on Critical Infrastructures.

    Science.gov (United States)

    Oakes, Benjamin Donald; Mattsson, Lars-Göran; Näsman, Per; Glazunov, Andrés Alayón

    2018-01-03

    Modern infrastructures are becoming increasingly dependent on electronic systems, leaving them more vulnerable to electrical surges or electromagnetic interference. Electromagnetic disturbances appear in nature, e.g., lightning and solar wind; however, they may also be generated by man-made technology to maliciously damage or disturb electronic equipment. This article presents a systematic risk assessment framework for identifying possible, consequential, and plausible intentional electromagnetic interference (IEMI) attacks on an arbitrary distribution network infrastructure. In the absence of available data on IEMI occurrences, we find that a systems-based risk assessment is more useful than a probabilistic approach. We therefore modify the often applied definition of risk, i.e., a set of triplets containing scenario, probability, and consequence, to a set of quadruplets: scenario, resource requirements, plausibility, and consequence. Probability is "replaced" by resource requirements and plausibility, where the former is the minimum amount and type of equipment necessary to successfully carry out an attack scenario and the latter is a subjective assessment of the extent of the existence of attackers who possess the motivation, knowledge, and resources necessary to carry out the scenario. We apply the concept of intrusion areas and classify electromagnetic source technology according to key attributes. Worst-case scenarios are identified for different quantities of attacker resources. The most plausible and consequential of these are deemed the most important scenarios and should provide useful decision support in a countermeasures effort. Finally, an example of the proposed risk assessment framework, based on notional data, is provided on a hypothetical water distribution network. © 2017 Society for Risk Analysis.

  5. Electromagnetic Interference (EMI) and TEMPEST Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Electromagnetic Interference (EMI), Electromagnetic Compatibility (EMC) and TEMPEST testing are conducted at EPG's Blacktail Canyon Test Facility in one of its two...

  6. Substation electromagnetic interference

    International Nuclear Information System (INIS)

    Felic, G.; Shihab, S.

    1997-01-01

    The electric and magnetic transients in high voltage substations were studied. The electric field measurements were carried out in a 66 kV switchyard of a 500/220/66 kV substation in Melbourne, Australia. The measured waveforms make up a database to be used for reference in the testing of substation control and protection equipment. The objective of this study was to characterize the radiated interference caused by the operation of disconnect switches and circuit breakers. Disconnect switch transients can be a serious hazard for substations because the slow moving contacts during opening and closing can result in arcing events of several seconds duration. Circuit breaker transients were considered to be less hazardous. Transient magnetic fields of at least several tens of A/m can occur during the energization of the capacitor bank. Substation electronic equipment should be tested and protected against the coupling of these transients in order to avoid breakdowns. 5 refs., 4 figs

  7. Personal medical electronic devices and walk-through metal detector security systems: assessing electromagnetic interference effects.

    Science.gov (United States)

    Guag, Joshua; Addissie, Bisrat; Witters, Donald

    2017-03-20

    There have been concerns that Electromagnetic security systems such as walk-through metal detectors (WTMDs) can potentially cause electromagnetic interference (EMI) in certain active medical devices including implantable cardiac pacemakers and implantable neurostimulators. Incidents of EMI between WTMDs and active medical devices also known as personal medical electronic devices (PMED) continue to be reported. This paper reports on emission measurements of sample WTMDs and testing of 20 PMEDs in a WTMD simulation system. Magnetic fields from sample WTMD systems were characterized for emissions and exposure of certain PMEDs. A WTMD simulator system designed and evaluated by FDA in previous studies was used to mimic the PMED exposures to the waveform from sample WTMDs. The simulation system allows for controlled PMED exposure enabling careful study with adjustable magnetic field strengths and exposure duration, and provides flexibility for PMED exposure at elevated levels in order to study EMI effects on the PMED. The PMED samples consisted of six implantable cardiac pacemakers, six implantable cardioverter defibrillators (ICD), five implantable neurostimulators, and three insulin pumps. Each PMED was exposed in the simulator to the sample WTMD waveforms using methods based on appropriate consensus test standards for each of the device type. Testing the sample PMEDs using the WTMD simulator revealed EMI effects on two implantable pacemakers and one implantable neurostimulator for exposure field strength comparable to actual WTMD field strength. The observed effects were transient and the PMEDs returned to pre-exposure operation within a few seconds after removal from the simulated WTMD exposure fields. No EMI was observed for the sample ICDs or insulin pumps. The findings are consistent with earlier studies where certain sample PMEDs exhibited EMI effects. Clinical implications were not addressed in this study. Additional studies are needed to evaluate potential PMED

  8. Carbon nanostructure composite for electromagnetic interference

    Indian Academy of Sciences (India)

    2015-05-30

    based composite materials for electromagnetic interference (EMI) shielding. With more and more electronic gadgets being used at different frequencies, there is a need for shielding them from one another to avoid interference.

  9. Electromagnetic interference in electrical systems of motor vehicles

    Science.gov (United States)

    Dziubiński, M.; Drozd, A.; Adamiec, M.; Siemionek, E.

    2016-09-01

    Electronic ignition system affects the electronic equipment of the vehicle by electric and magnetic fields. The measurement of radio electromagnetic interference originating from the ignition system affecting the audiovisual test bench was carried out with a variable speed of the ignition system. The paper presents measurements of radio electromagnetic interference in automobiles. In order to determine the level of electromagnetic interference, the audiovisual test bench was equipped with a set of meters for power consumption and assessment of the level of electromagnetic interference. Measurements of the electromagnetic interference level within the audiovisual system were performed on an experimental test bench consisting of the ignition system, starting system and charging system with an alternator and regulator.

  10. Immunizing digital systems against electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Second, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation problems associated with EMI will be greatly reduced

  11. Immunizing digital systems against electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Secondly, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation problems associated with EMI will be greatly reduced

  12. Conducted Electromagnetic Interference (EMI) in Smart Grids

    CERN Document Server

    Smolenski, Robert

    2012-01-01

    As power systems develop to incorporate renewable energy sources, the delivery systems may be disrupted by the changes involved. The grid’s technology and management must be developed to form Smart Grids between consumers, suppliers and producers. Conducted Electromagnetic Interference (EMI) in Smart Grids considers the specific side effects related to electromagnetic interference (EMI) generated by the application of these Smart Grids. Conducted Electromagnetic Interference (EMI) in Smart Grids presents specific EMI conducted phenomena as well as effective methods to filter and handle them once identified. After introduction to Smart Grids, the following sections cover dedicated methods for EMI reduction and potential avenues for future development including chapters dedicated to: •potential system services, •descriptions of the EMI spectra shaping methods, •methods of interference voltage compensation, and theoretical analysis of experimental results.  By focusing on these key aspects, Conducted El...

  13. Electromagnetic Interference in Smart Grids

    NARCIS (Netherlands)

    Leferink, Frank; Keyer, Cees

    2017-01-01

    The increasing conducted interference caused by modern electronic equipment is causing more problems for electronic, or static, energy meters. If equipped with a communication link they are called smart meter. Because the smart meter is a key device in smart grids, any deviation has huge impact on

  14. Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board.

    Science.gov (United States)

    Seckler, Tobias; Jagielski, Kai; Stunder, Dominik

    2015-05-27

    Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine‑bursts or by using a Qi A13 design wireless charging board (Qi‑A13‑Board) in two operating modes "power transfer" and "pinging". With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi‑A13‑Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi‑A13‑Board exceed the performance limits.

  15. Addressing the susceptibility of digital systems to electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Second, a verification and validation (V ampersand V) program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate acceptance criteria to ensure that the circuit or system under test meets the recommended guidelines. V ampersand V should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation susceptibility attributable to EMI will be greatly reduced

  16. Addressing the susceptibility of digital systems to electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Second, a verification and validation (V ampersand V) program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate acceptance should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation susceptibility attributable to EMI will be greatly reduced

  17. Interference and protection of electromagnetic pulse to digital signal processor

    International Nuclear Information System (INIS)

    Wang Yan; Jiao Hongling; He Shanhong; Pan Chao; Feng Deren; Che Wenquan; Xiong Ying

    2013-01-01

    The effective electromagnetic pulse protection is studied in this paper, first the interference of electromagnetic pulse simulator path is analyzed, including the digital signal processor (DSP) and the discharge circuit of coupling interference and net electricity coupling interference. Using the structure optimization design, the hardware block reinforcement measurement and the setting of open software trap, and the watchdog anti-jamming measures, the interference test is completed such as the central processor core voltage of DSP, input/output (I/O) ports of DSP and the display screen. The experimental results show that the combination of hardware and software protection reinforcement technology is effective, and the interference pulse amplitude of DSP board I/O port and the kernel work voltage are reduced, and the interference duration is reduced from 2 μs to 400 ns. The interference pulse is effectively restrained. (authors)

  18. Manager's Role in Electromagnetic Interference (EMI) Control

    Science.gov (United States)

    Sargent, Noel B.; Lewis, Catherine C.

    2013-01-01

    This presentation captures the essence of electromagnetic compatibility (EMC) engineering from a project manager's perspective. It explains the basics of EMC and the benefits to the project of early incorporation of EMC best practices. The EMC requirement products during a project life cycle are identified, along with the requirement verification methods that should be utilized. The goal of the presentation is to raise awareness and simplify the mystique surrounding electromagnetic compatibility for managers that have little or no electromagnetics background

  19. Vulnerability analysis of the wireless infrastructures to intentional electromagnetic interference

    NARCIS (Netherlands)

    van de Beek, G.S.

    2016-01-01

    Contemporary society is greatly dependent upon a set of critical infrastructures (CIs) providing security and quality of life. Electronic systems control the safety-critical functioning of most CIs, and these electronic systems are susceptible to electromagnetic interference (EMI). A threat to the

  20. Electromagnetic Interference in Implantable Rhythm Devices - The Indian Scenario

    Directory of Open Access Journals (Sweden)

    Johnson Francis

    2002-07-01

    Full Text Available Implantable rhythm device (IRD is the generic name for the group of implantable devices used for diagnosis and treatment of cardiac arrhythmias. Devices in this category include cardiac pacemakers, implantable cardioverter defibrillators and implantable loop recorders. Since these devices have complex microelectronic circuitry and use electromagnetic waves for communication, they are susceptible to interference from extraneous sources of electromagnetic radiation and magnetic energy. Electromagnetic interference (EMI is generally not a major problem outside of the hospital environment. The most important interactions occur when a patient is subjected to medical procedures such as magnetic resonance imaging (MRI, electrocautery and radiation therapy. Two articles in this issue of the journal discusses various aspects of EMI on IRD1,2 . Together these articles provide a good review of the various sources of EMI and their interaction with IRD for the treating physician.

  1. Electromagnetic interference analysis of magnetic resistance sensors inside a projectile under complex electromagnetic environments

    International Nuclear Information System (INIS)

    Guo, Qingwei; Gao, Min; Lu, Zhicai; Yang, Peijie

    2013-01-01

    Accurate measurement of angular motion has long been recognized as a daunting task. In recent years the measurement of projectiles utilizing magnetic resistance sensors has become a hot research field. Electromagnetic interference on attitude measurement cannot be ignored in complex electromagnetic environments such as battlefield conditions. In this paper, the influence and function pattern of electromagnetic interference on the measuring performance are theoretically analyzed, and the shielding effectiveness (SE) simulation of projectile is conducted via software Computer Simulation Technology (CST). Considering the specific tests, the intensity of the influence is judged. The simulation indicates that the battlefield's complex electromagnetic environment influences the environment inside the projectile, especially its electronic components and capability. The research results can provide important theoretical support on the errors compensation and precision improvement of the projectile attitude measurement with Magnetic Resistance sensor.

  2. Role of dressed-state interference in electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Khan, Sumanta; Bharti, Vineet; Natarajan, Vasant

    2016-01-01

    Highlights: • Role of dressed-state interference is investigated on lambda, ladder and vee type EIT systems. • The effect of interference decreases with increasing Rabi frequency of the control laser. • Dressed-state interference plays an important role in lambda system and a negligible role in ladder and vee systems. - Abstract: Electromagnetically induced transparency (EIT) in three-level systems uses a strong control laser on one transition to modify the absorption of a weak probe laser on a second transition. The control laser creates dressed states whose decay pathways show interference. We study the role of dressed-state interference in causing EIT in the three types of three-level systems—lambda (Λ), ladder (Ξ), and vee (V). In order to get realistic values for the linewidths of the energy levels involved, we consider appropriate hyperfine levels of "8"7Rb. For such realistic systems, we find that dressed-state interference causes probe absorption—given by the imaginary part of the susceptibility—to go to zero in a Λ system, but plays a negligible role in Ξ and V systems.

  3. Role of dressed-state interference in electromagnetically induced transparency

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Sumanta; Bharti, Vineet; Natarajan, Vasant

    2016-12-16

    Highlights: • Role of dressed-state interference is investigated on lambda, ladder and vee type EIT systems. • The effect of interference decreases with increasing Rabi frequency of the control laser. • Dressed-state interference plays an important role in lambda system and a negligible role in ladder and vee systems. - Abstract: Electromagnetically induced transparency (EIT) in three-level systems uses a strong control laser on one transition to modify the absorption of a weak probe laser on a second transition. The control laser creates dressed states whose decay pathways show interference. We study the role of dressed-state interference in causing EIT in the three types of three-level systems—lambda (Λ), ladder (Ξ), and vee (V). In order to get realistic values for the linewidths of the energy levels involved, we consider appropriate hyperfine levels of {sup 87}Rb. For such realistic systems, we find that dressed-state interference causes probe absorption—given by the imaginary part of the susceptibility—to go to zero in a Λ system, but plays a negligible role in Ξ and V systems.

  4. Embedding electromagnetic band gap structures in printed circuit boards for electromagnetic interference reduction

    NARCIS (Netherlands)

    Tereshchenko, O.V.

    2015-01-01

    Due to the tendency of faster data rates and lower power supply voltage in the integrated circuit (IC) design, Simultaneously Switching Noise (SSN) and ground bounce become serious concerns for designers and testers. This noise can be a source of electromagnetic interference (EMI). It propagates

  5. Electromagnetically induced interference in a superconducting flux qubit

    International Nuclear Information System (INIS)

    Du lingjie; Yu Yang; Lan Dong

    2013-01-01

    Interaction between quantum two-level systems (qubits) and electromagnetic fields can provide additional coupling channels to qubit states. In particular, the interwell relaxation or Rabi oscillations, resulting, respectively, from the multi- or single-mode interaction, can produce effective crossovers, leading to electromagnetically induced interference in microwave driven qubits. The environment is modeled by a multimode thermal bath, generating the interwell relaxation. Relaxation induced interference, independent of the tunnel coupling, provides deeper understanding to the interaction between the qubits and their environment. It also supplies a useful tool to characterize the relaxation strength as well as the characteristic frequency of the bath. In addition, we demonstrate the relaxation can generate population inversion in a strongly driving two-level system. On the other hand, different from Rabi oscillations, Rabi-oscillation-induced interference involves more complicated and modulated photon exchange thus offers an alternative means to manipulate the qubit, with more controllable parameters including the strength and position of the tunnel coupling. It also provides a testing ground for exploring nonlinear quantum phenomena and quantum state manipulation in qubits either with or without crossover structure.

  6. Electromagnetic Interference Analysis of Cabinet for Wireless HART Communication

    International Nuclear Information System (INIS)

    Choo, Jaeyul; Jeong, Sang Yong; Kim, Hyung Tae; Yu, Yeong Jin; Park, Hyun Shin; Jeong, Choong Heui

    2015-01-01

    Among the protocols of the wireless communication, the wireless HART communication using the carrier frequency of 2.4 GHz has attracted a lot of interest due to the convenient monitoring and measurement of the variables of nuclear power plants. However the application of the wireless communication to nuclear power plants poses an ongoing challenge due to the unwanted electromagnetic interference (EMI) caused by wireless devices, which would cause the detrimental malfunctioning to adjacent equipment. Especially the EMI problem in the cabinet containing digital instrument and control (I and C) devices is crucial to safety functions and should thus be treated electromagnetically before the use of the wireless communication in nuclear power plants is approved. The mode-matching method has been widely used in electromagnetic analysis due to the reduced computing time by the fast convergence in series solutions. Inspired by this, we perform the electromagnetic scattering analyses of an open cabinet using the modematching method. The resulting information of the electric (E) and magnetic (H) fields enables us to estimate how much the digital I and C in the cabinet is influenced by the external electromagnetic source. The mode-matching method was applied to the scattering analysis of the open cabinet for the digital I and C in nuclear power plants. The mathematical expressions with the unknown modal coefficients for electromagnetic field distributions were formulated based on Helmholtz's equation in conjunction with both the separation of variables and the Fourier transforms. We then determined the modal coefficients from the boundary conditions for electric and magnetic field continuities

  7. Electromagnetic Interference Analysis of Cabinet for Wireless HART Communication

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Jaeyul; Jeong, Sang Yong; Kim, Hyung Tae; Yu, Yeong Jin; Park, Hyun Shin; Jeong, Choong Heui [Korea Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    Among the protocols of the wireless communication, the wireless HART communication using the carrier frequency of 2.4 GHz has attracted a lot of interest due to the convenient monitoring and measurement of the variables of nuclear power plants. However the application of the wireless communication to nuclear power plants poses an ongoing challenge due to the unwanted electromagnetic interference (EMI) caused by wireless devices, which would cause the detrimental malfunctioning to adjacent equipment. Especially the EMI problem in the cabinet containing digital instrument and control (I and C) devices is crucial to safety functions and should thus be treated electromagnetically before the use of the wireless communication in nuclear power plants is approved. The mode-matching method has been widely used in electromagnetic analysis due to the reduced computing time by the fast convergence in series solutions. Inspired by this, we perform the electromagnetic scattering analyses of an open cabinet using the modematching method. The resulting information of the electric (E) and magnetic (H) fields enables us to estimate how much the digital I and C in the cabinet is influenced by the external electromagnetic source. The mode-matching method was applied to the scattering analysis of the open cabinet for the digital I and C in nuclear power plants. The mathematical expressions with the unknown modal coefficients for electromagnetic field distributions were formulated based on Helmholtz's equation in conjunction with both the separation of variables and the Fourier transforms. We then determined the modal coefficients from the boundary conditions for electric and magnetic field continuities.

  8. Electromagnetic interference shielding effectiveness of polypropylene/conducting fiber composites

    International Nuclear Information System (INIS)

    Lee, Pyoung-Chan; Kim, Bo-Ram; Jeoung, Sun Kyoung; Kim, Yeung Keun

    2016-01-01

    Electromagnetic released from the automotive electronic parts is harmful to human body. Electromagnetic interference (EMT) shielding refers to the reflection and/or adsorption of electromagnetic radiation by a material, which thereby acts as a shield against the penetration of the radiation through the shield. Polypropylene (PP)/conductive micro fiber composites containing various fiber contents and fiber length were injection-molded. The effect of fiber content and length on electrical properties of the composites was studied by electrical resistivity and EMT shielding measurements. The through-plane electrical conductivity and dielectric permittivity were obtained by measuring dielectric properties. The EMT shielding effectiveness (SE) was investigated by using S-parameter in the range of 100 ~ 1500 MHz. Reflection, absorption and multiple-reflection are the EMT attenuation mechanisms. From the measurement of S-Parameters, the absorption coefficient, reflection coefficient, and the shielding efficiency of the materials were calculated. The EMT SE of PP/conducing fiber composites is 40 dB over a wide frequency range up to 1.5 GHz, which is higher than that of PP/talc composite used automotive parts, viz. 0 dB.

  9. Electromagnetic interference of mobile phones with electronic implants

    International Nuclear Information System (INIS)

    Kainz, W.

    2000-03-01

    Chapter 1:Interference matrix: The objective of Chapter 1 was to give an overview of the implants used at present and their electromagnetic compatibility (EMC). The evaluation of the available literature provides an estimate of the probability of electronic implants being influenced by various interference sources. A literature search at the AKH (Allgemeines Krankenhaus) in Vienna and at the Technical University of Vienna in the FIZ (Fach-Informations-Zentrum) -Biomedizinische Technik, Medline, Pascal Biomed, CC Search und Embase databases yielded 236 relevant publications. At present 12 different implants are used: pacemaker, defibrillator, cochlear and brain-stem implants, neurostimulators, spinal-cord stimulators, spinal-fusion stimulators, telemetry systems, artificial hearts, drug-delivery systems, neurological pulse generators, visual prosthetics and implantable patient chips. The frequency with which they are used and the EMC on exposure to the various interference sources was summarized. Publications on EMC were found only for the first six implant types and only for 30% of the possible combinations of implant type and interference source. Based on the number of the implants examined, the probability of interference was calculated and summarized in the interference matrix. Chapter 2:Measurements on the phantom: No publication on the electromagnetic compatibility of neurological pulse generators (NPG) could be found. This implant has been used increasingly in the last few years to treat Parkinson's disease. A phantom was built to examine this implant at 900 MHz. The electromagnetic compatibility was measured by exposing the NPG to the fields of ten different 900 MHz GSM mobile phones. Every mobile phone was tested in three different positions relative to the phantom, with four electrode configurations and four stimulation parameters. No interference was found even at a maximum transmit power of 2 watts. Further tests with half-wave dipoles and increased

  10. Tough graphene-polymer microcellular foams for electromagnetic interference shielding.

    Science.gov (United States)

    Zhang, Hao-Bin; Yan, Qing; Zheng, Wen-Ge; He, Zhixian; Yu, Zhong-Zhen

    2011-03-01

    Functional polymethylmethacrylate (PMMA)/graphene nanocomposite microcellular foams were prepared by blending of PMMA with graphene sheets followed by foaming with subcritical CO(2) as an environmentally benign foaming agent. The addition of graphene sheets endows the insulating PMMA foams with high electrical conductivity and improved electromagnetic interference (EMI) shielding efficiency with microwave absorption as the dominant EMI shielding mechanism. Interestingly, because of the presence of the numerous microcellular cells, the graphene-PMMA foam exhibits greatly improved ductility and tensile toughness compared to its bulk counterpart. This work provides a promising methodology to fabricate tough and lightweight graphene-PMMA nanocomposite microcellular foams with superior electrical and EMI shielding properties by simultaneously combining the functionality and reinforcement of the graphene sheets and the toughening effect of the microcellular cells.

  11. Highly Efficient and Reliable Transparent Electromagnetic Interference Shielding Film.

    Science.gov (United States)

    Jia, Li-Chuan; Yan, Ding-Xiang; Liu, Xiaofeng; Ma, Rujun; Wu, Hong-Yuan; Li, Zhong-Ming

    2018-04-11

    Electromagnetic protection in optoelectronic instruments such as optical windows and electronic displays is challenging because of the essential requirements of a high optical transmittance and an electromagnetic interference (EMI) shielding effectiveness (SE). Herein, we demonstrate the creation of an efficient transparent EMI shielding film that is composed of calcium alginate (CA), silver nanowires (AgNWs), and polyurethane (PU), via a facile and low-cost Mayer-rod coating method. The CA/AgNW/PU film with a high optical transmittance of 92% achieves an EMI SE of 20.7 dB, which meets the requirements for commercial shielding applications. A superior EMI SE of 31.3 dB could be achieved, whereas the transparent film still maintains a transmittance of 81%. The integrated efficient EMI SE and high transmittance are superior to those of most previously reported transparent EMI shielding materials. Moreover, our transparent films exhibit a highly reliable shielding ability in a complex service environment, with 98 and 96% EMI SE retentions even after 30 min of ultrasound treatment and 5000 bending cycles (1.5 mm radius), respectively. The comprehensive performance that is associated with the facile fabrication strategy imparts the CA/AgNW/PU film with great potential as an optimized EMI shielding material in emerging optoelectronic devices, such as flexible solar cells, displays, and touch panels.

  12. Prediction of shipboard electromagnetic interference (EMI) problems using artificial intelligence (AI) technology

    Science.gov (United States)

    Swanson, David J.

    1990-08-01

    The electromagnetic interference prediction problem is characteristically ill-defined and complicated. Severe EMI problems are prevalent throughout the U.S. Navy, causing both expected and unexpected impacts on the operational performance of electronic combat systems onboard ships. This paper focuses on applying artificial intelligence (AI) technology to the prediction of ship related electromagnetic interference (EMI) problems.

  13. Optimised Spectral Kurtosis for bearing diagnostics under electromagnetic interference

    Science.gov (United States)

    Smith, Wade A.; Fan, Zhiqi; Peng, Zhongxiao; Li, Huaizhong; Randall, Robert B.

    2016-06-01

    The selection of the optimal demodulation frequency band is a significant step in bearing fault diagnosis because it determines whether the fault information can be extracted from the demodulated signal via envelope analysis. Two well-known methods for selecting the demodulation band are the Fast Kurtogram, based on the kurtosis of the filtered time signal, and the Protrugram, which uses the kurtosis of the envelope (amplitude) spectrum. Although these two methods have been successfully applied in many cases, the authors have observed that they may fail in specific environments, such as in the presence of electromagnetic interference (EMI) or other impulsive masking signals. In this paper, a simple spectral kurtosis-based approach is proposed for selecting the best demodulation band to extract bearing fault-related impulsive content from vibration signals contaminated with strong EMI. The method is applied to vibration signals obtained from a planetary gearbox test rig with planet bearings seeded with inner and outer race faults. Results from the Fast Kurtogram and Protrugram methods are also included for comparison. The proposed approach is found to exhibit superior diagnostic performance in the presence of intense EMI. Another contribution of the paper is to introduce and explain the issue of EMI to the condition monitoring community. The paper outlines the characteristics of EMI arising from widely-used variable frequency drives, and these characteristics are used to simulate an EMI-contaminated vibration signal to further test the performance of the proposed approach. Although EMI has been acknowledged as a serious problem in many industrial cases, there have been very few studies showing its adverse effects on machine diagnostics. It is important for analysts to be able to identify EMI in measured vibration signals, lest it interfere with the analysis undertaken.

  14. Experimental research for γ-ray interference threshold effect of high electromagnetic pulse sensor

    International Nuclear Information System (INIS)

    Meng Cui; Chen Xiangyue; Nie Xin; Xiang Hui; Guo Xiaoqiang; Mao Congguang; Cheng Jianping; Ni Jianping

    2007-01-01

    The high electromagnetic pulse (EMP) sensor using optical-fiber to transmit signal can restrain electromagnetic interference. The Compton electrons scattered by γ-ray irradiated from nuclear explosion or nuclear explosion simulator can generate high EMP, γ-ray can penetrate the shielding box and irradiate the integrated circuit directly. The γ-ray irradiation effect includes interference, latch up and burn out, these will make the measurement result unbelievable. In this paper, the experimental method researching the γ-ray irradiation effect of high electromagnetic pulse sensor on Qiangguang-I accelerator is introduced. The γ-ray dose rate interference threshold is 2 x 10 6 Gy/s. (authors)

  15. Technical basis for acceptance criteria on the susceptibility of digital systems to electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1992-01-01

    This paper discusses the development of the technical basis for establishing acceptance criteria on the susceptibility of digital systems to electromagnetic interference (EMI). The effort is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed with the application of digital instrumentation and controls systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic voltage levels, thereby leading to the risk of susceptibility when spurious interference is misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and their impact on other nearby circuits and systems. Then, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related problems associated with EMI will be greatly reduced

  16. Evaluation of electromagnetic interference environment of the instrumentation and control systems in nuclear power units

    Energy Technology Data Exchange (ETDEWEB)

    Min, Moon-Gi; Lee, Jae-Ki; Ji, Yeong-Haw; Jo, Sung-Han [Korea Hydro & Nuclear Power Co., Ltd., 1312-70 Yuesong-daero, Yuseong-Gu, Daejeon 305-343 (Korea, Republic of); Kim, Hee-Je, E-mail: heeje@pusan.ac.kr [Pusan National University, 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan 609-735 (Korea, Republic of)

    2015-04-15

    Highlights: • We surveyed the electromagnetic emissions at the location of I&C systems. • We assessed the electromagnetic levels on reactor types from thirteen nuclear plants. • We evaluated the margin between plant emission limits and the highest composite levels. • We presented the formula of radiated susceptibility test levels to non-safety-related I&C systems. - Abstract: The electromagnetic interference (EMI) generated from sources in power units can interfere with digital Instrument and Control (I&C) systems. When EMI is emitted with conducted and radiated noise, it interferes with the signals of the I&C systems. Since the digital I&C systems are efficient and competitively priced, the analogue I&C systems have been upgraded and replaced with digital I&C systems, but these systems have less EMI immunity. When safety-related I&C systems are installed in the units, the verification of equipment EMI should not be done in site-specific tests but in test facilities. There are needs to do the overall site-specific EMI assessment of I&C systems depending on the reactor types from thirteen operating units. This study evaluated the margin between plant emission limits and the highest composite plant emissions of the EMI. When the non-safety-related I&C equipment or systems are placed in the units, there are no individual test levels of the radiated electrical field. If need be, the level should comply with the test levels of the radiated electrical field on the safety-related I&C systems. This paper presents the test levels of radiated electrical fields to non-safety-related I&C equipment or systems.

  17. Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment

    NARCIS (Netherlands)

    Togt, R. van der; Lieshout, E.J. van; Hensbroek, R.; Beinat, E.; Binnekade, J.M.; Bakker, P.J.M.

    2008-01-01

    Context: Health care applications of autoidentification technologies, such as radio frequency identification (RFID), have been proposed to improve patient safety and also the tracking and tracing of medical equipment. However, electromagnetic interference (EMI) by RFID on medical devices has never

  18. Vulnerability of terrestrial-trunked radio to intelligent intentional electromagnetic interference

    NARCIS (Netherlands)

    Tanuhardja, Ray R.; van de Beek, G.S.; Bentum, Marinus Jan; Leferink, Frank Bernardus Johannes

    2015-01-01

    The terrestrial-trunked radio (TETRA) specification is produced by the European Telecommunication Standards Institute for private mobile radio systems. We investigated the resilience of TETRA against intelligent intentional electromagnetic interference (IEMI) with low amplitude. Low power signals

  19. Reducing Electromagnetic Interference in a Grid Tied Single Phase Power Inverter

    Science.gov (United States)

    2016-09-01

    With the growing demand for a reliable electrical grid, backup power supplies and energy management systems are a necessity. Systems such as server...ELECTROMAGNETIC INTERFERENCE IN A GRID TIED SINGLE PHASE POWER INVERTER by Jason Hassan Valiani September 2016 Thesis Advisor: Giovanna Oriti...3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE REDUCING ELECTROMAGNETIC INTERFERENCE IN A GRID TIED SINGLE PHASE POWER

  20. Study on Electromagnetic Interference of high-speed railway EMU

    OpenAIRE

    CHENG Qiang; LIU Jin-jiang; CHENG Ning

    2013-01-01

    Electromagnetic radiation generated by pantograph-catenaries detachment is one of the inevitable problems with the development of high-speed railway this paper is focusing on the generating mechanism and characteristics of electromagnetic noise caused by pantograph-catenaries system. Based on previous research, we build an integrated model of catenaries and locomotive system, and study the electromagnetic disturbance characteristics using software FEKO. The simulation experiment results in th...

  1. Interference Processes During Reradiation of Attosecond Pulses of Electromagnetic Field by Graphene

    Science.gov (United States)

    Makarov, D. N.; Matveev, V. I.; Makarova, K. A.

    2018-05-01

    Interference spectra during reradiation of attosecond pulses of electromagnetic field by graphene sheets are considered. Analytical expressions for calculations of spectral distributions are derived. As an example, the interference spectra of a graphene sheet and a flat rectangular lattice are compared.

  2. The electromagnetic interferent antennae for gravitational waves detection

    International Nuclear Information System (INIS)

    Kulak, A.

    1984-01-01

    An electromagnetic wave propagating in the toroidal waveguide is considered as an electromagnetic gravitational antenna. An interferometric method is applied to measure the disturbances of phase of the electromagnetic field caused by the incident gravitational wave. The calculations presented take into account the dispersive and dissipative phenomena occurring during the interaction between electromagnetic and gravitational fields. The active cross-section of the antenna interacting with coherent and pulsed gravitational radiation is estimated. Experimental possibilities presently available are discussed. Limiting fluxes in the astrophysical range of frequencies measured by the interferometric electromagnetic antenna are a factor of ten or so smaller than in the case of a classic mechanical antenna. Moreover the antenna could be used for carrying out a gravitational Hertz experiment. (author)

  3. Effects of Sm addition on electromagnetic interference shielding property of Mg-Zn-Zr alloys

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chubin [Chongqing University, College of Materials Science and Engineering, National Engineering Research Center for Magnesium Alloy, Chongqing (China); Gannan Normal University, Jiangxi Provincial Engineering Research Center for Magnesium Alloy, Ganzhou (China); Pan, Fusheng; Chen, Xianhua [Chongqing University, College of Materials Science and Engineering, National Engineering Research Center for Magnesium Alloy, Chongqing (China); Luo, Ning [Gannan Normal University, Jiangxi Provincial Engineering Research Center for Magnesium Alloy, Ganzhou (China)

    2017-06-15

    The electromagnetic interference (EMI) shielding of Sm-containing magnesium alloys in the 30-1500 MHz testing frequency range was investigated by coaxial cable method. The results demonstrated that Mg-3Zn alloys displayed the best electromagnetic shielding property. When 0.5 wt% of Zr was added for crystal grain refinement, the shielding effectiveness (SE) was apparently reduced. The addition of the rare earth element Sm in ZK magnesium alloys can improve the electromagnetic interference shielding of magnesium alloys. The main reason for the differences in electromagnetic interference shielding of magnesium alloys was the change in conductivity. The addition of Zr in Mg-Zn alloys can refine the grains and consequently improve the grain boundary area significantly. Therefore, the number of irregularly arranged atoms at the grain boundaries increased, decreasing the conductivity of magnesium alloys and leading to a decrease in the electromagnetic interference shielding. Following the Sm addition, the Mg-Zn-Sm phase was precipitated at the grain boundaries and in cores. The precipitation of Sm-containing rare earth phases could consume the solid-soluted Zn atoms within the Mg, resulting in an increase in electrical conductivity and electromagnetic interference shielding improvement. (orig.)

  4. Electromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders

    Directory of Open Access Journals (Sweden)

    Marcos de Sousa

    2002-07-01

    Full Text Available Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI and patients with Implantable rhythm devices (IRD like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagnetic interference occurs when electromagnetic waves emitted by one device impede the normal function of another electronic device. The potential for interaction between implanted pacing systems and cardioverter-defibrillators (electromagnetic interference, EMI has been recognized for years.1,2,3,4. It has been shown that EMI can produce clinically significant effects on patients with implanted pacemakers and ICDs. For these reasons the following text discusses the influence of several EMI generating devices on IRD .

  5. Electromagnetic interference-induced instability in CPP-GMR read heads

    International Nuclear Information System (INIS)

    Khunkitti, P.; Siritaratiwat, A.; Kaewrawang, A.; Mewes, T.; Mewes, C.K.A.; Kruesubthaworn, A.

    2016-01-01

    Electromagnetic interference (EMI) has been a significant issue for the current perpendicular-to-the-plane giant magnetoresistance (CPP-GMR) read heads because it can cause magnetic failure. Furthermore, the magnetic noise induced by the spin transfer torque (STT) effect has played an important role in the CPP read heads because it can affect the stability of the heads. Accordingly, this work proposed an investigation of the magnetic instabilities induced by EMI through the STT effect in a CPP-GMR read head via micromagnetic simulations. The magnetization fluctuation caused by EMI was examined, and then, magnetic noise was evaluated by using power spectral density analysis. It was found that the magnetization orientation can be fluctuated by EMI in close proximity to the head. The results also showed a multimode spectral density. The main contributions of the spectral density were found to originate at the edges of the stripe height sides due to the characteristics of the demagnetization field inside the free layer. Hence, the magnetic instabilities produced by EMI become a significant factor that essentially impacts the reliability of the CPP-GMR read heads. - Highlights: • The instability induced by electromagnetic interference in read head is examined. • The magnetization orientation can be fluctuated by electromagnetic interference. • The electromagnetic interference can induce additional noise spectra to the system. • The noise is mainly located at stripe height of the read head. • The noise induced by electromagnetic interference is a crucial factor for the head.

  6. Electromagnetic interference-induced instability in CPP-GMR read heads

    Energy Technology Data Exchange (ETDEWEB)

    Khunkitti, P.; Siritaratiwat, A.; Kaewrawang, A. [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Mewes, T.; Mewes, C.K.A. [Department of Physics and Astronomy, MINT Center, University of Alabama, Tuscaloosa, AL 35487 (United States); Kruesubthaworn, A., E-mail: anankr@kku.ac.th [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand)

    2016-08-15

    Electromagnetic interference (EMI) has been a significant issue for the current perpendicular-to-the-plane giant magnetoresistance (CPP-GMR) read heads because it can cause magnetic failure. Furthermore, the magnetic noise induced by the spin transfer torque (STT) effect has played an important role in the CPP read heads because it can affect the stability of the heads. Accordingly, this work proposed an investigation of the magnetic instabilities induced by EMI through the STT effect in a CPP-GMR read head via micromagnetic simulations. The magnetization fluctuation caused by EMI was examined, and then, magnetic noise was evaluated by using power spectral density analysis. It was found that the magnetization orientation can be fluctuated by EMI in close proximity to the head. The results also showed a multimode spectral density. The main contributions of the spectral density were found to originate at the edges of the stripe height sides due to the characteristics of the demagnetization field inside the free layer. Hence, the magnetic instabilities produced by EMI become a significant factor that essentially impacts the reliability of the CPP-GMR read heads. - Highlights: • The instability induced by electromagnetic interference in read head is examined. • The magnetization orientation can be fluctuated by electromagnetic interference. • The electromagnetic interference can induce additional noise spectra to the system. • The noise is mainly located at stripe height of the read head. • The noise induced by electromagnetic interference is a crucial factor for the head.

  7. Evaluation of electromagnetic interference between electromagnet and permanent magnet of reed switch of SMART control rod driver mechanism

    International Nuclear Information System (INIS)

    Hur, H.; Kim, J. H.; Park, J. S.; Yoo, J. Y.; Kim, J. I.

    2002-01-01

    Integral reactors require a fine reactivity control CEDM since the nuclear heating is used during the startup. Although a linear pulse motor type had been chosen for the SMART CEDM, a ball screw type is being considered as an alternative. A ball screw type CEDM driven by a rotary step motor has an emergency insertion system using electromagnet and also has a permanent magnet for RSPT in the upper pressure housing above the electromagnet. So it is necessary to evaluate an electromagnetic interference for reed switches in the vicinity of the electromagnet. This paper describes the design parameters for effective operation and the optimum design point was determined by analyzing the trend of the EMI characteristics

  8. Weak-electromagnetic interference in polarized eD scattering

    International Nuclear Information System (INIS)

    Prescott, C.Y.

    1992-09-01

    Observation of parity non-conservation in deep-inelastic scattering of polarized electrons from deuterium was reported in an experiment at SLAC in 1978. The events at SLAC and elsewhere leading to the successful search for parity non-conservation in the electromagnetic processes are described

  9. Electromagnetic interference reduction using electromagnetic bandgap structures in packages, enclosures, cavities, and antennas

    Science.gov (United States)

    Mohajer Iravani, Baharak

    Electromagnetic interference (EMI) is a source of noise problems in electronic devices. The EMI is attributed to coupling between sources of radiation and components placed in the same media such as package or chassis. This coupling can be either through conducting currents or through radiation. The radiation of electromagnetic (EM) fields is supported by surface currents. Thus, minimizing these surface currents is considered a major and critical step to suppress EMI. In this work, we present novel strategies to confine surface currents in different applications including packages, enclosures, cavities, and antennas. The efficiency of present methods of EM noise suppression is limited due to different drawbacks. For example, the traditional use of lossy materials and absorbers suffers from considerable disadvantages including mechanical and thermal reliability leading to limited life time, cost, volume, and weight. In this work, we consider the use of Electromagnetic Band Gap (EBG) structures. These structures are suitable for suppressing surface currents within a frequency band denoted as the bandgap. Their design is straight forward, they are inexpensive to implement, and they do not suffer from the limitations of the previous methods. A new method of EM noise suppression in enclosures and cavity-backed antennas using mushroom-type EBG structures is introduced. The effectiveness of the EBG as an EMI suppresser is demonstrated using numerical simulations and experimental measurements. To allow integration of EBGs in printed circuit boards and packages, novel miniaturized simple planar EBG structures based on use of high-k dielectric material (epsilonr > 100) are proposed. The design consists of meander lines and patches. The inductive meander lines serve to provide current continuity bridges between the capacitive patches. The high-k dielectric material increases the effective capacitive load substantially in comparison to commonly used material with much lower

  10. The electromagnetic bio-field: clinical experiments and interferences.

    Science.gov (United States)

    Burnei, G; Hodorogea, D; Georgescu, I; Gavriliu, Ş; Drăghici, I; Dan, D; Vlad, C; Drăghici, L

    2012-06-12

    One of the most important factors is the technical and scientifically rapid development that is continually modifying the world we live in and polluting it with electromagnetic radiations. A functional and structural influence of magnetic and electromagnetic field on living organisms is presented in the literature by many performed experiments. The notion of bio-field represents the electromagnetic field generated by the bio-structures, not only in their normal physiological activities but also in their pathological states. There is a tight interdependency between the bio-field and the bio-structure, which respects the primary notion of an electromagnetic field given by the Maxwell-Faraday laws, in which, the electromagnetic phenomena are simplified to the field variations. These variations can be expressed in a coherent differential equation system that bounds the field vectors to different space points at different time moments. The living organisms cannot contain electrostatic and magneto-static fields due to the intense activity of the bio-structures. The biochemical reactions that have high rhythms and speeds always impose the electrodynamics character of the biologic field that also corresponds to the stability of the protein molecule that can be explained only through a dynamic way. The existent energy is not considered an exciting agent, and it does not lead to any effects. The parameters of these elementary bio-fields cannot yet be fully known due to technical reasons. The biological structures are very complex ones and undergo continuous dynamical activity. That is why the calculus model should be related to the constant dynamics, nowadays being very difficult to express.

  11. CHARACTERIZATION OF THE COHERENT NOISE, ELECTROMAGNETIC COMPATIBILITY AND ELECTROMAGNETIC INTERFERENCE OF THE ATLAS EM CALORIMETER FRONT END BOARD

    International Nuclear Information System (INIS)

    CHASE, B.; CITTERIO, M.; LANNI, F.; MAKOWIECKI, D.; RADEKA, S.; RESCIA, S.; TAKAI, H.

    1999-01-01

    The ATLAS Electromagnetic (EM) calorimeter (EMCAL) Front End Board (FEB) will be located in custom-designed enclosures solidly connected to the feedtroughs. It is a complex mixed signal board which includes the preamplifier, shaper, switched capacitor array analog memory unit (SCA), analog to digital conversion, serialization of the data and related control logic. It will be described in detail elsewhere in these proceedings. The electromagnetic interference (either pick-up from the on board digital activity, from power supply ripple or from external sources) which affects coherently large groups of channels (coherent noise) is of particular concern in calorimetry and it has been studied in detail

  12. CHARACTERIZATION OF THE COHERENT NOISE, ELECTROMAGNETIC COMPATIBILITY AND ELECTROMAGNETIC INTERFERENCE OF THE ATLAS EM CALORIMETER FRONT END BOARD

    International Nuclear Information System (INIS)

    CHASE, R.L.; CITTERIO, M.; LANNI, F.; MAKOWIECKI, D.; RADEKA, V.; RESCIA, S.; TAKAI, H.; BAN, J.; PARSONS, J.; SIPPACH, W.

    2000-01-01

    The ATLAS Electromagnetic (EM) calorimeter (EMCAL) Front End Board (FEB) will be located in custom-designed enclosures solidly connected to the feedtroughs. It is a complex mixed signal board which includes the preamplifier, shaper, switched capacitor array analog memory unit (SCA), analog to digital conversion, serialization of the data and related control logic. It will be described in detail elsewhere in these proceedings. The electromagnetic interference (either pick-up from the on board digital activity, from power supply ripple or from external sources) which affects coherently large groups of channels (coherent noise) is of particular concern in calorimetry and it has been studied in detail

  13. Assessment of life interference in anxious children

    DEFF Research Database (Denmark)

    Rapee, Ronald; Thastum, Mikael; Chavira, Denise

    associated with mental disorders arguably the key issue of relevance to both sufferers and therapists. Yet among both childhood and adult disorders the primary focus in terms of assessment and treatment is on symptoms, with far less attention paid to the impact of these symptoms on the sufferer's life....... This imbalance has particularly characterised research on child anxiety where few studies have examined either the impact of anxiety disorders on children's lives or the effects of treatments on life interference. To some extent this lack of attention has come from a lack of well developed measures to assess...... life interference derived from symptoms of anxiety. Broader and more general life interference measures tend to have minimal relevance for children with anxiety disorders. The current paper will describe two measures of life interference that have been developed at the Centre for Emotional Health...

  14. Electromagnetic Interference to Flight Navigation and Communication Systems: New Strategies in the Age of Wireless

    Science.gov (United States)

    Ely, Jay J.

    2005-01-01

    Electromagnetic interference (EMI) promises to be an ever-evolving concern for flight electronic systems. This paper introduces EMI and identifies its impact upon civil aviation radio systems. New wireless services, like mobile phones, text messaging, email, web browsing, radio frequency identification (RFID), and mobile audio/video services are now being introduced into passenger airplanes. FCC and FAA rules governing the use of mobile phones and other portable electronic devices (PEDs) on board airplanes are presented along with a perspective of how these rules are now being rewritten to better facilitate in-flight wireless services. This paper provides a comprehensive overview of NASA cooperative research with the FAA, RTCA, airlines and universities to obtain laboratory radiated emission data for numerous PED types, aircraft radio frequency (RF) coupling measurements, estimated aircraft radio interference thresholds, and direct-effects EMI testing. These elements are combined together to provide high-confidence answers regarding the EMI potential of new wireless products being used on passenger airplanes. This paper presents a vision for harmonizing new wireless services with aeronautical radio services by detecting, assessing, controlling and mitigating the effects of EMI.

  15. Lightning induced inappropriate ICD shock: an unusual case of electromagnetic interference.

    Science.gov (United States)

    Anderson, Daniel R; Gillberg, Jeffrey M; Torrey, Jeffrey W; Koneru, Jayanthi N

    2012-06-01

    An unusual case of electromagnetic interference is presented. As a result of a lightning shock to a Shower House, our patient received two shocks. An elucidation of the different mechanisms for the two shocks is presented. ©2010, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  16. Generation of complete coherence in Young's interference experiment with random mutually uncorrelated electromagnetic beams

    NARCIS (Netherlands)

    Agarwal, G. S.; Dogariu, A.; Visser, T.D.; Wolf, E.

    2005-01-01

    The recently developed theory that unifies the treatments of polarization and coherence of random electro-magnetic beams is applied to study field correlations in Young's interference experiment. It is found that at certain pairs of points the transmitted field is spatially fully coherent,

  17. Systematic Design of a Transimpedance Amplifier With Specified Electromagnetic Out-of-Band Interference Behavior

    NARCIS (Netherlands)

    van der Horst, Marcel J.; Linnenbank, Andre C.; Serdijn, Wouter A.; Long, John R.

    2010-01-01

    In negative-feedback amplifier design, electromagnetic interference (EMI) behavior is usually completely disregarded. EMI can, e.g., result in detection of low-frequency envelope variations of the usually high-frequency interfering signals. If the detected signals end up in the pass band of the

  18. [The effect of an experimental occlusal interference on the masticatory cycle recorded by electromagnetic pantography].

    Science.gov (United States)

    Godefroy, J N; Yardin, M

    1991-06-01

    The effects of occlusal interference on masticatory cycles have been studied in twenty nine volunteers with complete natural dentition, using an electromagnetic pantograph (Sirognatograph, Siemens A.G.). After a one week recall, a decrease in speed motion was noted and the range of cycles in the horizontal plane had been altered.

  19. Electromagnetic interference of bone-anchored hearing aids by cellular phones.

    Science.gov (United States)

    Kompis, M; Negri, S; Häusler, R

    2000-10-01

    We report a case of electromagnetic interference between a bone-anchored hearing aid (BAHA) and a cellular phone. A 54-year-old women was successfully treated for severe mixed conductive and sensorineural hearing loss with a BAHA. Five years after implantation, the patient experienced a sudden feeling of dizziness, accompanied by a loud buzzing sound and by a sensation of head pressure while examining a digital mobile phone. During a subsequent experiment, the buzzing sound could be reproduced and was identified as electromagnetic interference between the BAHA and digital cellular phones. Seventeen adult BAHA users from our clinic participated in a subsequent survey. Of the 13 patients with some experience of digital cellular phones, 11 reported hearing annoying noises elicited by these devices. However, no other sensation, such as dizziness, was described. Owing to the increasing number of users of both hearing aids and cellular phones, the incidence of electromagnetic interference must be expected to increase as well. Although to date there is no evidence that such interference may be harmful or dangerous to users of conventional or bone-anchored hearing aids, unexpected interference can be a frightening experience.

  20. Electromagnetic Interference Issues of A Wireless Power Transmission Converter

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Haji Bashi, Mazaher; Silva, Filipe Miguel Faria da

    2018-01-01

    field and the leakage current flowing through stray capacitors. In this paper, the EMI of wireless power transmission technology is highlighted and for the first time evaluated from a new perspective. The possible parasitic paths are identified simply. Additionally, effective high-frequency models......Many recent studies have focused on the inductive charging to transfer electrical power from a source to batteries without any electrical interface. The main problem with them is that inductive charging technologies may have electromagnetic compatibility (EMC) issues caused by the leakage magnetic...... for each part of the inductive charger are presented. At the first, the lowest EMI technology for wireless charging is chosen and simulated. To overcome the EMI and leakage current problems, this paper also suggests using a new passive EMI filter topology. Simulation results show the necessity...

  1. Intraoperative visualization and assessment of electromagnetic tracking error

    Science.gov (United States)

    Harish, Vinyas; Ungi, Tamas; Lasso, Andras; MacDonald, Andrew; Nanji, Sulaiman; Fichtinger, Gabor

    2015-03-01

    Electromagnetic tracking allows for increased flexibility in designing image-guided interventions, however it is well understood that electromagnetic tracking is prone to error. Visualization and assessment of the tracking error should take place in the operating room with minimal interference with the clinical procedure. The goal was to achieve this ideal in an open-source software implementation in a plug and play manner, without requiring programming from the user. We use optical tracking as a ground truth. An electromagnetic sensor and optical markers are mounted onto a stylus device, pivot calibrated for both trackers. Electromagnetic tracking error is defined as difference of tool tip position between electromagnetic and optical readings. Multiple measurements are interpolated into the thin-plate B-spline transform visualized in real time using 3D Slicer. All tracked devices are used in a plug and play manner through the open-source SlicerIGT and PLUS extensions of the 3D Slicer platform. Tracking error was measured multiple times to assess reproducibility of the method, both with and without placing ferromagnetic objects in the workspace. Results from exhaustive grid sampling and freehand sampling were similar, indicating that a quick freehand sampling is sufficient to detect unexpected or excessive field distortion in the operating room. The software is available as a plug-in for the 3D Slicer platforms. Results demonstrate potential for visualizing electromagnetic tracking error in real time for intraoperative environments in feasibility clinical trials in image-guided interventions.

  2. Effects of electromagnetic shielding cases for semiconductor-type electronic personal dosimeters on preventing electromagnetic interference

    International Nuclear Information System (INIS)

    Deji, Shizuhiko; Ito, Shigeki; Nishizawa, Kunihide; Saze, Takuya; Mori, Kazuyuki

    2005-01-01

    Performance of electromagnetic shielding cases for preventing malfunction of semiconductor-type electronic personal dosimeters (SEPDs) caused by high frequency electromagnetic fields emitted from a digital cellular telephone (cell phone) and a card reader of access control system were analyzed. The cases were handcrafted by using cloth of activated carbon fiber, polyester film laminated metal, and two kinds of metal netting. Five kinds of SEPDs put in the cases were exposed to the high frequency electromagnetic fields for 50 sec or 1 min. The cases prevented perfectly the malfunction due to the cell phone. The cases shortened distances required to prevent the malfunction due to the card reader, but did not prevent the malfunction. The electromagnetic immunity level of SEPD inserted in the cases increased from greater than 11.2 to greater than 18.7 times for the cell phone and from 1.1 to greater than 4.3 times for the card reader. The maximum of electromagnetic shielding effectiveness of each case was greater than 18.7 times for the cell phone and greater than 4.3 times for the card reader. (author)

  3. Study of electromagnetic interference on quench detecting system of HTS current leads for EAST

    International Nuclear Information System (INIS)

    Hu, Yanlan; Li, Jiangang; Ji, Zhenshan; Zhu, C.M.; Zhen, L.G.; Xiao, Y.Z.

    2013-01-01

    Highlights: • EAST HTS superconducting magnet system shall be operating in a very noisy environment. • Voltage taps will have a lot of inductive voltage induced on them which makes quench detection very difficult. • The noise comes from the coupling between rapid pulsed poloidal coils, and radiation coupling interference associated with EAST heating systems;. • A series of related electromagnetic compatibility simulation tests have been carried out. • Electromagnetic noises are well restrained by choosing proper anti-interference means. -- Abstract: High temperature superconducting (HTS) material B-2223/Ag-Au has been used for EAST poloidal field (PF) coil current leads for reducing construction and operation cost of cryogenic system. The quench propagation velocity of HTS superconducting material is several orders of magnitude lower than that of normal low temperature current leads. It is difficult to detect weak signal of quench which is easily influenced by strong electromagnetic interference (EMI). In this paper, the sources of EMI from quench detecting system of high temperature current leads have been introduced. And we have chosen reasonable methods for good transformation and protection on the basis of electromagnetic compatibility simulation diagnosis experiments. Recent experimental results showed that the restraint of EMI has been achieved and has met the requirements of experiment

  4. Near-field interference for the unidirectional excitation of electromagnetic guided modes.

    Science.gov (United States)

    Rodríguez-Fortuño, Francisco J; Marino, Giuseppe; Ginzburg, Pavel; O'Connor, Daniel; Martínez, Alejandro; Wurtz, Gregory A; Zayats, Anatoly V

    2013-04-19

    Wave interference is a fundamental manifestation of the superposition principle with numerous applications. Although in conventional optics, interference occurs between waves undergoing different phase advances during propagation, we show that the vectorial structure of the near field of an emitter is essential for controlling its radiation as it interferes with itself on interaction with a mediating object. We demonstrate that the near-field interference of a circularly polarized dipole results in the unidirectional excitation of guided electromagnetic modes in the near field, with no preferred far-field radiation direction. By mimicking the dipole with a single illuminated slit in a gold film, we measured unidirectional surface-plasmon excitation in a spatially symmetric structure. The surface wave direction is switchable with the polarization.

  5. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    Energy Technology Data Exchange (ETDEWEB)

    J. Cunningham and J. Shank

    2004-11-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner.

  6. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    International Nuclear Information System (INIS)

    Cunningham, J.; Shank, J.

    2004-01-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner

  7. The effect of electromagnetic interference from mobile communication on the performance of intensive care ventilators.

    Science.gov (United States)

    Jones, R P; Conway, D H

    2005-08-01

    Electromagnetic interference produced by wireless communication can affect medical devices and hospital policies exist to address this risk. During the transfer of ventilated patients, these policies may be compromised by essential communication between base and receiving hospitals. Local wireless networks (e.g. Bluetooth) may reduce the 'spaghetti syndrome' of wires and cables seen on intensive care units, but also generate electromagnetic interference. The aim of this study was to investigate these effects on displayed and actual ventilator performance. Five ventilators were tested: Drager Oxylog 2000, BREAS LTV-1000, Respironics BiPAP VISION, Puritan Bennett 7200 and 840. Electromagnetic interference was generated by three devices: Simoco 8020 radio handset, Nokia 7210 and Nokia 6230 mobile phone, Nokia 6230 communicating via Bluetooth with a Palm Tungsten T Personal Digital Assistant. We followed the American National Standard Recommended Practice for On-Site, Ad Hoc Testing (ANSI C63) for electromagnetic interference. We used a ventilator tester, to simulate healthy adult lungs and measure ventilator performance. The communication device under test was moved in towards each ventilator from a distance of 1 m in six axes. Alarms or error codes on the ventilator were recorded, as was ventilator performance. All ventilators tested, except for the Respironics VISION, showed a display error when subjected to electromagnetic interference from the Nokia phones and Simoco radio. Ventilator performance was only affected by the radio which caused the Puritan Bennett 840 to stop functioning completely. The transfer ventilators' performance were not affected by radio or mobile phone, although the mobile phone did trigger a low-power alarm. Effects on intensive care ventilators included display reset, with the ventilator restoring normal display function within 2 s, and low-power/low-pressure alarms. Bluetooth transmission had no effect on the function of all the

  8. AANA Journal Course: update for nurse anesthetists. Arrhythmia management devices and electromagnetic interference.

    Science.gov (United States)

    Mattingly, Emily

    2005-04-01

    The technological complexity of implantable arrhythmia management devices, specifically pacemakers and defibrillators, has increased dramatically since their introduction only a few decades ago. Patients with such devices are encountered much more frequently in hospitals and surgery centers, yet anesthesia provider knowledge of safe and proper management is often incomplete. Anesthesia textbooks and references may provide only short paragraphs on arrhythmia management devices that do not address important perioperative management strategies for this ever-growing patient population. It is no longer satisfactory to simply place a magnet over an implanted device during surgery and assume that this action protects the patient from harm due to electromagnetic interference from inappropriate device function. This AANA Journal course serves as a concise review of basic device function, the sources and effects of electromagnetic interference in the operative setting, and patient management recommendations from current literature.

  9. Inelastic processes and interference effects during the interaction of positronium with ultrashort electromagnetic pulses

    Energy Technology Data Exchange (ETDEWEB)

    Eseev, M. K., E-mail: m_eseev@mail.ru; Matveev, V. I., E-mail: matveev.victor@pomorsu.ru [Lomonosov Northern (Arctic) Federal University (Russian Federation)

    2013-11-15

    The excitation, breakup, and reradiation during the interaction of a positronium atom with ultrashort electromagnetic pulses are considered. The probabilities of inelastic processes and reradiation spectra have been obtained. The interference between the amplitudes of the photon emission by the electron and positron is shown to contribute noticeably to the reradiation spectra. The developed approach is applicable for describing the interaction of positronium with ultrashort pulses of attosecond or shorter duration.

  10. Laser diode current controller with a high level of protection against electromagnetic interference

    Czech Academy of Sciences Publication Activity Database

    Lazar, Josef; Jedlička, Petr; Číp, Ondřej; Růžička, Bohdan

    2003-01-01

    Roč. 74, č. 8 (2003), s. 3816 - 3819 ISSN 0034-6748 R&D Projects: GA AV ČR IBS2508201; GA AV ČR IAA2065803; GA ČR GA101/01/1104; GA AV ČR IBS2065009 Institutional research plan: CEZ:AV0Z2065902 Keywords : laser diode * electromagnetic interference * ripple free voltage Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.343, year: 2003

  11. Polarization of the interference field during reflection of electromagnetic waves from an intermedia boundary

    Science.gov (United States)

    Bulakhov, M. G.; Buyanov, Yu. I.; Yakubov, V. P.

    1996-10-01

    It has been shown that a full vector measurement of the total field allows one to uniquely distinguish the incident and reflected waves at each observation point without the use of a spatial difference based on an analysis of the polarization structure of the interference pattern which arises during reflection of electromagnetic waves from an intermedia boundary. We have investigated the stability of these procedures with respect to measurement noise by means of numerical modeling.

  12. Survey of ambient electromagnetic and radio-frequency interference levels in nuclear power plants

    International Nuclear Information System (INIS)

    Kercel, S.W.; Moore, M.R.; Blakeman, E.D.; Ewing, P.D.; Wood, R.T.

    1996-11-01

    This document reports the results of a survey of ambient electromagnetic conditions in representative nuclear power plants. The U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research engaged the Oak Ridge National Laboratory (ORNL) to perform these measurements to characterize the electromagnetic interference (EMI) and radio-frequency interference (RFI) levels that can be expected in nuclear power plant environments. This survey is the first of its kind, being based on long-term unattended observations. The data presented in this report were measured at eight different nuclear units and required 14 months to collect. A representative sampling of power plant conditions (reactor type, operating mode, site location) monitored over extended observation periods (up to 5 weeks) were selected to more completely determine the characteristic electromagnetic environment for nuclear power plants. Radiated electric fields were measured over the frequency range of 5 MHz to 8 GHz. Radiated magnetic fields and conducted EMI events were measured over the frequency range of 305 Hz to 5 MHz. Highest strength observations of the electromagnetic ambient environment across all measurement conditions at each site provide frequency-dependent profiles for EMI/RFI levels in nuclear power plants

  13. Experimentation at LEP: weak-electromagnetic interference, QED and two-photon physics

    International Nuclear Information System (INIS)

    Davier, M.

    1979-01-01

    The energy range opened by LEP will permit a clean and direct study of the weak interaction. Of particular importance are those effects resulting from the interference between the weak and the electromagnetic (EM) currents: it is shown that they give access to the basic couplings which can be measured unambiguously. The paper is in three parts. The first and major section deals with the weak interaction experiments. Most of the calculations and estimates rely on the Weinberg-Salam model as a realistic guide of what might happen. The second section is devoted to 2γ processes. On one hand they constitute an interesting physics study which has been assessed both from theory and experiment and appears promising. On the other hand, they can generate background to many annihilation channels and this aspect has been studied in detail. The last section presents a brief look at short distance tests of Quantum Electrodynamics (QED) - a restricted, but important area of research at LEP. (Auth.)

  14. Reduction of Electromagnetic Interference Using ZnO-PCL Nanocomposites at Microwave Frequency

    Directory of Open Access Journals (Sweden)

    Abubakar Yakubu

    2015-01-01

    Full Text Available In industrial equipment and home appliance applications, the electromagnetic compatibility compliance directive (ECCD demands that electromagnetic interference side effects be eliminated or marginally minimized. The equipment must not disturb radio and telecommunication as well as other appliances. Additionally the ECCD also governs the immunity of such equipment to interference and seeks to ensure that this equipment is not disturbed by radio emissions when used as intended. Many types of absorbing materials are commercially available. However, many are expensive and not environmentally friendly. It is in the light of the above that we studied the electromagnetic absorption properties of ZnO-PCL nanocomposites prepared from cheap and abundant resources which are environmentally friendly (zinc and polycaprolactone. The test was carried out using a microstrip, open ended coaxial probe, and vector network analyzer. Amongst other findings, result showed that the ZnO-PCL nanocomposite has the capability of attenuating microwave frequency up to −18.2 dB due to their very high specific surface areas attributed to the nanofillers at 12 GHz.

  15. Electromagnetic Compatibility Assessment of CCD Detector Acquisition Chains not Synchronized

    Science.gov (United States)

    Nicoletto, M.; Boschetti, D.; Ciancetta, E.; Maiorano, E.; Stagnaro, L.

    2016-05-01

    Euclid is a space observatory managed by the European Space Agency; it is the second medium class mission (see Figure 1) in the frame of Cosmic Vision 2015-2025 program.In the frame of this project, the electromagnetic interference between two different and not synchronized Charge Coupled Device (CCD) (see Figure 2) acquisition chains has been evaluated. The key parameter used for this assessment is the electromagnetic noise induced on each other. Taking into account the specificity of the issue, radiation coupling at relative low frequency and in near field conditions, classical approach based on simulations and testing on qualification model cannot be directly applied. Based on that, it has been decided to investigate the issue by test in an incremental way.

  16. Modelling natural electromagnetic interference in man-made conductors for space weather applications

    Science.gov (United States)

    Trichtchenko, Larisa

    2016-04-01

    Power transmission lines above the ground, cables and pipelines in the ground and under the sea, and in general all man-made long grounded conductors are exposed to the variations of the natural electromagnetic field. The resulting currents in the networks (commonly named geomagnetically induced currents, GIC), are produced by the conductive and/or inductive coupling and can compromise or even disrupt system operations and, in extreme cases, cause power blackouts, railway signalling mis-operation, or interfere with pipeline corrosion protection systems. To properly model the GIC in order to mitigate their impacts it is necessary to know the frequency dependence of the response of these systems to the geomagnetic variations which naturally span a wide frequency range. For that, the general equations of the electromagnetic induction in a multi-layered infinitely long cylinder (representing cable, power line wire, rail or pipeline) embedded in uniform media have been solved utilising methods widely used in geophysics. The derived electromagnetic fields and currents include the effects of the electromagnetic properties of each layer and of the different types of the surrounding media. This exact solution then has been used to examine the electromagnetic response of particular samples of long conducting structures to the external electromagnetic wave for a wide range of frequencies. Because the exact solution has a rather complicated structure, simple approximate analytical formulas have been proposed, analysed and compared with the results from the exact model. These approximate formulas show good coincidence in the frequency range spanning from geomagnetic storms (less than mHz) to pulsations (mHz to Hz) to atmospherics (kHz) and above, and can be recommended for use in space weather applications.

  17. Electromagnetic interference produced by power or electrified railway lines on metallic pipe networks

    International Nuclear Information System (INIS)

    Lucca, G.

    1999-01-01

    The paper presents an algorithm for the calculation, in the frequency domain, of the induced voltages and currents on a generic metallic pipe network exposed to the electromagnetic interference from a power line or an electrified railway line. By assuming as known the voltages and the currents on the inducing line, the algorithm may be subdivided into the following main steps: a) determination of the ideal electromotive force and current generators to be applied to the induced structure in order to represent the electromagnetic influence from the inducing line; b) modelling of the pipe network by means of a suitable equivalent electric network; c) calculation of voltages and currents on the induced network [it

  18. Electromagnetic interference shielding properties and mechanisms of chemically reduced graphene aerogels

    International Nuclear Information System (INIS)

    Bi, Shuguang; Zhang, Liying; Mu, Chenzhong; Liu, Ming; Hu, Xiao

    2017-01-01

    Graphical abstract: The electromagnetic interference shielding behavior and proposed mechanisms of ultralight free-standing 3D graphene aerogels. - Highlights: • The electromagnetic interference (EMI) shielding properties and mechanisms of ultralight 3D graphene aerogels (GAs) were systematically studied with respect to both the unique porous network and the intrinsic properties of the graphene sheets. • Thickness of the shielding material played a critical role on EMI SE. • By compressing the porous GAs into compact film didnt increase the EMI SE despite the increased electrical conductivity and connectivity. EMI SE is highly dependent on the effective amounts of the materials response to the EM waves. - Abstract: Graphene was recently demonstrated to exhibit excellent electromagnetic interference (EMI) shielding performance. In this work, ultralight (∼5.5 mg/cm"3) graphene aerogels (GAs) were fabricated through assembling graphene oxide (GO) using freeze-drying followed by a chemical reduction method. The EMI shielding properties and mechanisms of GAs were systematically studied with respect to the intrinsic properties of the reduced graphene oxide (rGO) sheets and the unique porous network. The EMI shielding effectiveness (SE) of GAs was increased from 20.4 to 27.6 dB when the GO was reduced by high concentration of hydrazine vapor. The presence of more sp"2 graphitic lattice and free electrons from nitrogen atoms resulted in the enhanced EMI SE. Absorption was the dominant shielding mechanism of GAs. Compressing the highly porous GAs into compact thin films did not change the EMI SE, but shifted the dominant shielding mechanism from absorption to reflection.

  19. Electromagnetic interference shielding properties and mechanisms of chemically reduced graphene aerogels

    Energy Technology Data Exchange (ETDEWEB)

    Bi, Shuguang [Temasek Laboratories, Nanyang Technological University, 50 Nanyang Drive, 637553 (Singapore); Zhang, Liying, E-mail: LY.Zhang@ntu.edu.sg [Temasek Laboratories, Nanyang Technological University, 50 Nanyang Drive, 637553 (Singapore); Mu, Chenzhong [School of Material Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore); Liu, Ming, E-mail: LIUMING@ntu.edu.sg [Temasek Laboratories, Nanyang Technological University, 50 Nanyang Drive, 637553 (Singapore); Hu, Xiao [Temasek Laboratories, Nanyang Technological University, 50 Nanyang Drive, 637553 (Singapore); School of Material Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore)

    2017-08-01

    Graphical abstract: The electromagnetic interference shielding behavior and proposed mechanisms of ultralight free-standing 3D graphene aerogels. - Highlights: • The electromagnetic interference (EMI) shielding properties and mechanisms of ultralight 3D graphene aerogels (GAs) were systematically studied with respect to both the unique porous network and the intrinsic properties of the graphene sheets. • Thickness of the shielding material played a critical role on EMI SE. • By compressing the porous GAs into compact film didnt increase the EMI SE despite the increased electrical conductivity and connectivity. EMI SE is highly dependent on the effective amounts of the materials response to the EM waves. - Abstract: Graphene was recently demonstrated to exhibit excellent electromagnetic interference (EMI) shielding performance. In this work, ultralight (∼5.5 mg/cm{sup 3}) graphene aerogels (GAs) were fabricated through assembling graphene oxide (GO) using freeze-drying followed by a chemical reduction method. The EMI shielding properties and mechanisms of GAs were systematically studied with respect to the intrinsic properties of the reduced graphene oxide (rGO) sheets and the unique porous network. The EMI shielding effectiveness (SE) of GAs was increased from 20.4 to 27.6 dB when the GO was reduced by high concentration of hydrazine vapor. The presence of more sp{sup 2} graphitic lattice and free electrons from nitrogen atoms resulted in the enhanced EMI SE. Absorption was the dominant shielding mechanism of GAs. Compressing the highly porous GAs into compact thin films did not change the EMI SE, but shifted the dominant shielding mechanism from absorption to reflection.

  20. Proceedings: Electromagnetic interference control in modern digital instrumentation and control upgrades

    International Nuclear Information System (INIS)

    1993-06-01

    A workshop on Electro-Magnetic Interference (EMI) Control in Modern Digital Instrumentation ampersand Control System Upgrade was held in Baltimore on September 10-11, 1992 to provide a forum for technology transfer, technical information exchange, and education. The workshop was attended by more than 70 representatives of electric utilities, equipment manufacturers, engineering consulting organizations, and government agencies. The workshop consists of four sessions: (1) Organizational EMC Perspectives, (2) EMI Environment, Case Histories ampersand Solutions, (3) EMC in Digital Instrumentation ampersand Control Systems, and (4) EMI Utility Needs. A group discussion followed the presentations to identify utility needs. Individual papers have been cataloged separately

  1. Air-gap Limitations and Bypass Techniques: “Command and Control” using Smart Electromagnetic Interferences

    Directory of Open Access Journals (Sweden)

    Chaouki Kasmi

    2016-01-01

    Full Text Available Air gaps are generally considered to be a very efficient information security protection. However, this technique also showed limitations, involving finding covert channels for bridging the air gap. Interestingly, recent publications have pointed out that a smart use of the intentional electromagnetic interferences introduced new threats for information security. In this paper, an innovative way for remotely communicating with a malware already installed on a computer by involving the induced perturbations is discussed leading to the design of a new air gap bridging covert channel.

  2. Anti-electromagnetic interference analysis of equivalent circuit of ion channel based on the Hodgkin-Huxley model

    International Nuclear Information System (INIS)

    Chu, J; Chang, X L; Zhao, M; Man, M H; Wei, M; Yuan, L

    2013-01-01

    With the continuous improvement of circuit integration and working clock frequency in the electronic system, it is increasingly easy for the system to be affected by electromagnetic waves, and electromagnetic susceptibility and vulnerability become more severe. However, living beings in nature have shown extraordinary compatibility, immunity and adaptability to the electromagnetism at the same time. In addition, the ion channel on the neuron cytomembrane is a typical representation of b ioelectrical immunity . So the Hodgkin-Huxley circuit model with one capacitor in parallel with some power supplies and resistors was adopted to simulate the ion channel on the neuron cytomembrane. Through analysis, the circuit model can be used to simulate some electrical characteristics of biological neuron cells, and then acquire a certain level of anti-electromagnetic interference ability. This method will be useful for improving the reliability, compatibility and anti-interference capability of the electronic system in the complicated electromagnetic environment.

  3. Shielding effectiveness of a unit of neuro physiology against electromagnetic interference

    International Nuclear Information System (INIS)

    Febles Santana, V.; Miguel Bilbao, S. de; Lubary Rodriguez, C. S.; Melian del Castillo, M. R.; Herraz Gomez, J. G.; Ramos Gonzalez, V.; Fernandez de Aldecoa, J. C.

    2011-01-01

    During construction of the new building Ambulatory Activity in the Hospital Universitario de Canarias (HUC), was designed and implemented the shield in the form of Faraday cage, five rooms adjacent to the Unit of Neuro physiology, located at the northeast corner 3C plant of the building, in order to sufficiently attenuate radio signals present in the medium and thus enable correct functionality of electro medical equipment free of artifacts caused by external electromagnetic fields. The experience held, once finished the work and commissioning the unit, is that interference is undesirable in some cases even hinder the proper development of medical diagnostic studies. Therefore, technical staff of the Engineering Branch of HUC, initiated a program of measures to determine the effectiveness of the Faraday cage constructed, checking the attenuation levels achieved for frequencies of interest and, if necessary, the deficiencies identified in the design and execution of it, and proposed improvements to minimize interference problems exist.

  4. Polarization-induced interference within electromagnetically induced transparency for atoms of double-V linkage

    Science.gov (United States)

    Sun, Yuan; Liu, Chang; Chen, Ping-Xing; Liu, Liang

    2018-02-01

    People have been paying attention to the role of atoms' complex internal level structures in the research of electromagnetically induced transparency (EIT) for a long time, where the various degenerate Zeeman levels usually generate complex linkage patterns for the atomic transitions. It turns out, with special choices of the atomic states and the atomic transitions' linkage structure, clear signatures of quantum interference induced by the probe and coupling light's polarizations can emerge from a typical EIT phenomena. We propose to study a four-state system with double-V linkage pattern for the transitions and analyze the polarization-induced interference under the EIT condition. We show that such interference arises naturally under mild conditions on the optical field and atom manipulation techniques. Moreover, we construct a variation form of double-M linkage pattern where the polarization-induced interference enables polarization-dependent cross modulation between incident weak lights that can be effective even at the few-photon level. The theme is to gain more insight into the essential question: how can we build a nontrivial optical medium where incident lights experience polarization-dependent nonlinear optical interactions, valid for a wide range of incidence intensities down to the few-photon level?

  5. Shielding and filtering techniques to protect sensitive instrumentation from electromagnetic interference caused by arc welding

    International Nuclear Information System (INIS)

    Kalechstein, W.

    1997-01-01

    Electromagnetic interference (EMI) caused by arc welding is a concern for sensitive CANDU instrumentation and control equipment, especially start-up instrumentation (SUI) and ion chamber instruments used to measure neutron flux at low power. Measurements of the effectiveness of simple shielding and filtering techniques that may be applied to limit arc welding electromagnetic emissions below the interference threshold are described. Shielding configurations investigated include an arrangement in which the welding power supply, torch (electrode holder), interconnecting cables and welder operator were housed in a single enclosure and a more practical configuration of separate shields for the power supply, cables and operator with torch. The two configuration were found to provide 30 dB and 26 dB attenuation, respectively, for arc welder electric-field emissions and were successful in preventing EMI in SUI set up just outside the shielding enclosures. Practical improvements that may be incorporated in the shielding arrangement to facilitate quick setup in the field in a variety of application environments, while maintaining adequate EMI protection, are discussed. (author)

  6. Electromagnetic Interference from Swimming Pool Generator Current Causing Inappropriate ICD Discharges

    Directory of Open Access Journals (Sweden)

    Edward Samuel Roberto

    2017-01-01

    Full Text Available Electromagnetic interference (EMI includes any electromagnetic field signal that can be detected by device circuitry, with potentially serious consequences: incorrect sensing, pacing, device mode switching, and defibrillation. This is a unique case of extracardiac EMI by alternating current leakage from a submerged motor used to recycle chlorinated water, resulting in false rhythm detection and inappropriate ICD discharge. A 31-year-old female with arrhythmogenic right ventricular cardiomyopathy and Medtronic dual-chamber ICD placement presented after several inappropriate ICD shocks at the public swimming pool. Patient had never received prior shocks and device was appropriate at all regular follow-ups. Intracardiac electrograms revealed unique, high-frequency signals at exactly 120 msec suggestive of EMI from a strong external source of alternating current. Electrical artifact was incorrectly sensed as a ventricular arrhythmia which resulted in discharge. ICD parameters including sensing, pacing thresholds, and impedance were all normal suggesting against device malfunction. With device failure and intracardiac sources excluded, EMI was therefore strongly suspected. Avoidance of EMI source brought complete resolution with no further inappropriate shocks. After exclusion of intracardiac interference, device malfunction, and abnormal settings, extracardiac etiologies such as EMI must be thoughtfully considered and excluded. Elimination of inappropriate shocks is to “first, do no harm.”

  7. Investigation of electromagnetic interference effects by ESD simulator on test parameters of tunneling magnetic recording heads

    Energy Technology Data Exchange (ETDEWEB)

    Kruesubthaworn, A., E-mail: anankr@kku.ac.th [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Khunkitti, P.; Siritaratiwat, A.; Kaewrawang, A. [KKU-Seagate Cooperation Research Laboratory, Department of Electrical Engineering, Khon Kaen University, Khon Kaen 40002 (Thailand); Mewes, T.; Mewes, C.K.A. [Department of Physics and Astronomy, MINT Center, University of Alabama, Tuscaloosa, AL 35487 (United States)

    2017-01-01

    Electrostatic discharge (ESD) has been an important issue in the manufacturing processes of hard disk drive. It can also generate electromagnetic interference (EMI) which could possibly damage magnetic recording heads. The aims of this work are to measure the EMI from ESD events and to examine the effects of EMI on the heads. The discharge current and the EMI generated by an ESD simulator were experimentally measured. Also, the EMI was applied to the heads to determine if this can cause changes of head parameters. Our results show that the discharge current waveform is consistent with the theoretical waveform of the IEC ESD standard. Additionally, we found that the EMI applied due to ESD at distances greater than 2 cm does not have any significant effect on the head parameters. Hence, further detailed experiments are proposed to evaluate the EMI effects on recording head parameters in order to improve the measurement methodologies to prevent the degradation of the heads performance and to increase the robustness of the heads. - Highlights: • The electrostatic discharge (ESD) has been an important issue for the hard disk drive. • The electromagnetic interference (EMI) radiated by ESD IEC 61000-4-2 was focused. • Effects of the EMI on the magnetic recording head were examined. • The change of parameters of the writer and reader due to the EMI was measured. • The EMI could not cause any significant affectation on the writer and reader.

  8. [Electromagnetic interference in the current era of cardiac implantable electronic devices designed for magnetic resonance environment].

    Science.gov (United States)

    Ribatti, Valentina; Santini, Luca; Forleo, Giovanni B; Della Rocca, Domenico; Panattoni, Germana; Scali, Marta; Schirripa, Valentina; Danisi, Nicola; Ammirati, Fabrizio; Santini, Massimo

    2017-04-01

    In the last decades we are observing a continuous increase in the number of patients wearing cardiac implantable electronic devices (CIEDs). At the same time, we face daily with a domestic and public environment featured more and more by the presence and the utilization of new emitters and finally, more medical procedures are based on electromagnetic fields as well. Therefore, the topic of the interaction of devices with electromagnetic interference (EMI) is increasingly a real and actual problem.In the medical environment most attention is paid to magnetic resonance, nevertheless the risk of interaction is present also with ionizing radiation, electrical nerve stimulation and electrosurgery. In the non-medical environment, most studies reported in the literature focused on mobile phones, metal detectors, as well as on headphones or digital players as potential EMI sources, but many other instruments and tools may be intentional or non-intentional sources of electromagnetic fields.CIED manufacturers are more and more focusing on new technological features in order to make implantable devices less susceptible to EMI. However, patients and emitter manufacturers should be aware that limitations exist and that there is not complete immunity to EMI.

  9. A theory of electrical conductivity, dielectric constant, and electromagnetic interference shielding for lightweight graphene composite foams

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Xiaodong [School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092 (China); Department of Mechanical and Aerospace Engineering, Rutgers University, New Brunswick, New Jersey 08903 (United States); Wang, Yang; Weng, George J., E-mail: weng@jove.rutgers.edu [Department of Mechanical and Aerospace Engineering, Rutgers University, New Brunswick, New Jersey 08903 (United States); Zhong, Zheng [School of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai 200092 (China)

    2016-08-28

    This work was driven by the need to understand the electromagnetic interference (EMI) shielding effectiveness (SE) of light weight, flexible, and high performance graphene composite foams, but as EMI SE of a material depends on its electrical conductivity, dielectric permittivity, and magnetic permeability, the investigation of these three properties also became a priority. In this paper, we first present a continuum theory to determine these three electromagnetic properties, and then use the obtained properties to evaluate the EMI SE of the foam. A two-scale composite model is conceived to evaluate these three properties, with the large one being the skeleton-void composite and the small one being the graphene-polymer composite that serves as the skeleton of the foam. To evaluate the properties of the skeleton, the effective-medium approach is taken as the starting point. Subsequently, the effect of an imperfect interface and the contributions of electron tunneling to the interfacial conductivity and Maxwell-Wagner-Sillars polarization mechanism to the dielectric constant are also implemented. The derived skeleton properties are then utilized on the large scale to determine the three properties of the composite foam at a given porosity. Then a uniform plane electromagnetic wave is considered to evaluate the EMI SE of the foam. It is demonstrated that the electrical conductivity, dielectric constant, and EMI SE of the foam calculated from the developed theory are in general agreement with the reported experimental data of graphene/PDMS composite foams. The theory is further proven to be valid for the EMI SE of solid graphene/epoxy and solid carbon nanotube/epoxy nanocomposites. It is also shown that, among the three electromagnetic properties, electrical conductivity has the strongest influence on the EMI shielding effectiveness.

  10. An electromagnetic compatibility study of cardiac pacemaker to low frequency interferences

    International Nuclear Information System (INIS)

    Andretzko, J.P.; Hedjiedj, A.; Babouri, A.; Guendouz, L.; Nadi, M.

    2006-01-01

    This paper presents an experimental study of the behaviour of cardiac pacemaker submitted to low frequency electromagnetic interferences. The method used in this study is progressive. It consists in starting from the target (the cardiac pacemaker), identifying and quantifying the disturbances (the source), and then introducing secondary influencing parameters in stepwise fashion. The general problematic consists in checking this immunity in relation with led disruptions and in relation with beaming disruptions. The experimental approach suggests two kind of tests corresponding to the two studied coupling modes. The first one corresponds to a direct applying of the disruptive signal between the pacemaker terminals. The objective of this phase is to determine the characteristics of the signal (amplitude and frequency) which are detected by the pacemaker and which generate modifications of its operation. In the second phase the pacemaker is subjected to a variable low frequency magnetic field. This last interacts with the pacemaker by inductive coupling through the loop formed by the pacemaker and its leads and the surrounding medium. This interaction results in an induced electromotive force between the terminals of the pacemaker which can potentially disturb the operation of this last. The objective of this phase is to characterize the signal (magnetic field) likely to generate these disturbances. Tests are carried out on six single chamber pacemaker and five dual chamber pacemaker. The interfering signal frequencies are 50 Hz, 60 Hz, 10 khz and 25 khz. Tracking and programming of the pacemaker housing is achieved with the telemetry system. In this study, the devices have all been configured in inhibited stimulation (S.S.I. or V.V.I. mode according to the international codification), this configuration being the most widespread. The housing stimulates the basic frequency in the absence o f intrinsic activity, the stimulation can be inhibited in each chamber by a

  11. An electromagnetic compatibility study of cardiac pacemaker to low frequency interferences

    Energy Technology Data Exchange (ETDEWEB)

    Andretzko, J.P.; Hedjiedj, A.; Babouri, A.; Guendouz, L.; Nadi, M. [Nancy-1 Univ. Henri Poincare, Lab. d' Instrumentation Electronique de Nancy, Faculte des Sciences, 54 - Vandoeuvre les Nancy (France)

    2006-07-01

    This paper presents an experimental study of the behaviour of cardiac pacemaker submitted to low frequency electromagnetic interferences. The method used in this study is progressive. It consists in starting from the target (the cardiac pacemaker), identifying and quantifying the disturbances (the source), and then introducing secondary influencing parameters in stepwise fashion. The general problematic consists in checking this immunity in relation with led disruptions and in relation with beaming disruptions. The experimental approach suggests two kind of tests corresponding to the two studied coupling modes. The first one corresponds to a direct applying of the disruptive signal between the pacemaker terminals. The objective of this phase is to determine the characteristics of the signal (amplitude and frequency) which are detected by the pacemaker and which generate modifications of its operation. In the second phase the pacemaker is subjected to a variable low frequency magnetic field. This last interacts with the pacemaker by inductive coupling through the loop formed by the pacemaker and its leads and the surrounding medium. This interaction results in an induced electromotive force between the terminals of the pacemaker which can potentially disturb the operation of this last. The objective of this phase is to characterize the signal (magnetic field) likely to generate these disturbances. Tests are carried out on six single chamber pacemaker and five dual chamber pacemaker. The interfering signal frequencies are 50 Hz, 60 Hz, 10 khz and 25 khz. Tracking and programming of the pacemaker housing is achieved with the telemetry system. In this study, the devices have all been configured in inhibited stimulation (S.S.I. or V.V.I. mode according to the international codification), this configuration being the most widespread. The housing stimulates the basic frequency in the absence o f intrinsic activity, the stimulation can be inhibited in each chamber by a

  12. Interference effects during the reradiation of ultrashort electromagnetic pulses by polyatomic systems

    Energy Technology Data Exchange (ETDEWEB)

    Makarov, D. N.; Matveev, V. I., E-mail: mezon98@mail.ru [Lomonosov Northern (Arctic) Federal University (Russian Federation)

    2013-11-15

    A theory of the reradiation of ultrashort electromagnetic pulses by arbitrary polyatomic systems of isolated complex atoms has been developed. The technique used allows the spatial inhomogeneity of the field of an ultrashort pulse and photon momenta in reradiation processes to be accurately taken into account. The angular distributions of the reradiation spectra have been obtained for an arbitrary number of atoms in the system. The processes of interference between the photon emission amplitudes are shown to give rise to characteristic “diffraction” maxima. We consider one-dimensional, two-dimensional, and three-dimensional rectangular lattices as examples as well as planar and cylindrical structures as models of planar nanosystems and nanotubes.

  13. Status of NRC approval of EPRI electromagnetic interference susceptibility testing guidelines for digital equipment

    International Nuclear Information System (INIS)

    James, R.W.; Shank, J.W.; Yoder, C.

    1996-01-01

    Historically, nuclear power plants installing digital equipment have been required to conduct expensive, site-specific electromagnetic interference (EMI) surveys to demonstrate that EMI will not affect the operation of sensitive electronic equipment. Consequently, EPRI formed a Utility Working Group which developed a set of generic EMI susceptibility testing guidelines, which were published as an EPRI report in September 1994. These guidelines are based upon EMI survey data obtained from several different plants and include criteria for determining their applicability. The Working Group interacted with NRC staff to obtain NRC approval. In April 1996, the NRC issued a Safety Evaluation Report (SER) endorsing the guidelines as a valid means of demonstrating EMI compatibility. The issuance of this SER was conditional on issuing a revision to the EPRI EMI Guidelines. This paper summarizes the guidelines, the NRC SER, and the current status of Revision 1 to the report

  14. Electromagnetic interference modeling and suppression techniques in variable-frequency drive systems

    Science.gov (United States)

    Yang, Le; Wang, Shuo; Feng, Jianghua

    2017-11-01

    Electromagnetic interference (EMI) causes electromechanical damage to the motors and degrades the reliability of variable-frequency drive (VFD) systems. Unlike fundamental frequency components in motor drive systems, high-frequency EMI noise, coupled with the parasitic parameters of the trough system, are difficult to analyze and reduce. In this article, EMI modeling techniques for different function units in a VFD system, including induction motors, motor bearings, and rectifierinverters, are reviewed and evaluated in terms of applied frequency range, model parameterization, and model accuracy. The EMI models for the motors are categorized based on modeling techniques and model topologies. Motor bearing and shaft models are also reviewed, and techniques that are used to eliminate bearing current are evaluated. Modeling techniques for conventional rectifierinverter systems are also summarized. EMI noise suppression techniques, including passive filter, Wheatstone bridge balance, active filter, and optimized modulation, are reviewed and compared based on the VFD system models.

  15. Ag induced electromagnetic interference shielding of Ag-graphite/PVDF flexible nanocomposites thinfilms

    Science.gov (United States)

    Kumaran, R.; Alagar, M.; Dinesh Kumar, S.; Subramanian, V.; Dinakaran, K.

    2015-09-01

    We report Ag nanoparticle induced Electromagnetic Interference (EMI) shielding in a flexible composite films of Ag nanoparticles incorporated graphite/poly-vinylidene difluoride (PVDF). PVDF nanocomposite thin-films were synthesized by intercalating Ag in Graphite (GIC) followed by dispersing GIC in PVDF. The X-ray diffraction analysis and the high-resolution transmission electron microscope clearly dictate the microstructure of silver nanoparticles in graphite intercalated composite of PVDF matrix. The conductivity values of nanocomposites are increased upto 2.5 times when compared to neat PVDF having a value of 2.70 S/cm at 1 MHz. The presence of Ag broadly enhanced the dielectric constant and lowers the dielectric loss of PVDF matrix proportional to Ag content. The EMI shielding effectiveness of the composites is 29.1 dB at 12.4 GHz for the sample having 5 wt. % Ag and 10 wt. % graphite in PVDF.

  16. Weak-electromagnetic interference effects in the production of hadrons in electron-positron collisions

    International Nuclear Information System (INIS)

    Nieves, J.F.

    1980-01-01

    A framework for a systematic study of the weak-electromagnetic interference effects in the production of hadrons in e - e + collisions is presented and, in the case of the inclusive processes, the predictions of the quark-parton model are given. The approach to the calculation of these effects in e - e + H + X, where H is a pseudoscalar meson, a spin-1/2 baryon, or a vector meson, consists of setting down a general formula for the appropriate transition probability in terms of structure functions whose form is delimited by symmetry considerations. The quark-parton model is then used to express the structure functions in terms of the quark couplings and fragmentation probabilities. In this fashion the forward-backward asymmetry A/sub H/ and longitudinal polarization P/sub H/ are calculated in terms of the vector (a/sub q/) and axial-vector (b/sub q/) weak-neutral-current couplings of the quarks composing H, their electric charges Q/sub q/, and their (q → H) fragmentation probabilities. Using a theoretical argument for hadrons containing one heavy c,b,...quark, and SU(3) symmetry for hadrons composed of light u,d,s quarks, A/sub H/ is expressed in terms of b/sub q/ and Q/sub q/ only. In similar fashion, some relations between the various P/sub H/, independent of the fragmentation probabilities, are obtained. The results are discussed in detail for the strange and charmed hadrons.The exclusive processes e - e + → M anti M and e - e + → MV, where M is a pseudoscalar meson and V is a vector meson, are also discussed and the possibility of observing the weak-electromagnetic interference effects when M and V contain the t quark is noted

  17. A Novel Application of Machine Learning Methods to Model Microcontroller Upset Due to Intentional Electromagnetic Interference

    Science.gov (United States)

    Bilalic, Rusmir

    A novel application of support vector machines (SVMs), artificial neural networks (ANNs), and Gaussian processes (GPs) for machine learning (GPML) to model microcontroller unit (MCU) upset due to intentional electromagnetic interference (IEMI) is presented. In this approach, an MCU performs a counting operation (0-7) while electromagnetic interference in the form of a radio frequency (RF) pulse is direct-injected into the MCU clock line. Injection times with respect to the clock signal are the clock low, clock rising edge, clock high, and the clock falling edge periods in the clock window during which the MCU is performing initialization and executing the counting procedure. The intent is to cause disruption in the counting operation and model the probability of effect (PoE) using machine learning tools. Five experiments were executed as part of this research, each of which contained a set of 38,300 training points and 38,300 test points, for a total of 383,000 total points with the following experiment variables: injection times with respect to the clock signal, injected RF power, injected RF pulse width, and injected RF frequency. For the 191,500 training points, the average training error was 12.47%, while for the 191,500 test points the average test error was 14.85%, meaning that on average, the machine was able to predict MCU upset with an 85.15% accuracy. Leaving out the results for the worst-performing model (SVM with a linear kernel), the test prediction accuracy for the remaining machines is almost 89%. All three machine learning methods (ANNs, SVMs, and GPML) showed excellent and consistent results in their ability to model and predict the PoE on an MCU due to IEMI. The GP approach performed best during training with a 7.43% average training error, while the ANN technique was most accurate during the test with a 10.80% error.

  18. Transparent Conducting Graphene Hybrid Films To Improve Electromagnetic Interference (EMI) Shielding Performance of Graphene.

    Science.gov (United States)

    Ma, Limin; Lu, Zhengang; Tan, Jiubin; Liu, Jian; Ding, Xuemei; Black, Nicola; Li, Tianyi; Gallop, John; Hao, Ling

    2017-10-04

    Conducting graphene-based hybrids have attracted considerable attention in recent years for their scientific and technological significance in many applications. In this work, conductive graphene hybrid films, consisting of a metallic network fully encapsulated between monolayer graphene and quartz-glass substrate, were fabricated and characterized for their electromagnetic interference shielding capabilities. Experimental results show that by integration with a metallic network the sheet resistance of graphene was significantly suppressed from 813.27 to 5.53 Ω/sq with an optical transmittance at 91%. Consequently, the microwave shielding effectiveness (SE) exceeded 23.60 dB at the K u -band and 13.48 dB at the K a -band. The maximum SE value was 28.91 dB at 12 GHz. Compared with the SE of pristine monolayer graphene (3.46 dB), the SE of graphene hybrid film was enhanced by 25.45 dB (99.7% energy attenuation). At 94% optical transmittance, the sheet resistance was 20.67 Ω/sq and the maximum SE value was 20.86 dB at 12 GHz. Our results show that hybrid graphene films incorporate both high conductivity and superior electromagnetic shielding comparable to existing ITO shielding modalities. The combination of high conductivity and shielding along with the materials' earth-abundant nature, and facile large-scale fabrication, make these graphene hybrid films highly attractive for transparent EMI shielding.

  19. A survey on electromagnetic interferences on aircraft avionics systems and a GSM on board system overview

    Science.gov (United States)

    Vinto, Natale; Tropea, Mauro; Fazio, Peppino; Voznak, Miroslav

    2014-05-01

    Recent years have been characterized by an increase in the air traffic. More attention over micro-economic and macroeconomic indexes would be strategic to gather and enhance the safety of a flight and customer needing, for communicating by wireless handhelds on-board aircrafts. Thus, European Telecommunications Standards Institute (ETSI) proposed a GSM On Board (GSMOBA) system as a possible solution, allowing mobile terminals to communicate through GSM system on aircraft, avoiding electromagnetic interferences with radio components aboard. The main issues are directly related with interferences that could spring-out when mobile terminals attempt to connect to ground BTS, from the airplane. This kind of system is able to resolve the problem in terms of conformance of Effective Isotropic Radiated Power (EIRP) limits, defined outside the aircraft, by using an On board BTS (OBTS) and modeling the relevant key RF parameters on the air. The main purpose of this work is to illustrate the state-of-the-art of literature and previous studies about the problem, giving also a good detail of technical and normative references.

  20. Electromagnetic interference of implantable cardiac devices from a shoulder massage machine.

    Science.gov (United States)

    Yoshida, Saeko; Fujiwara, Kousaku; Kohira, Satoshi; Hirose, Minoru

    2014-09-01

    Shoulder massage machines have two pads that are driven by solenoid coils to perform a per cussive massage on the shoulders. There have been concerns that such machines might create electromagnetic interference (EMI) in implantable cardiac devices because of the time-varying magnetic fields produced by the alternating current in the solenoid coils. The objective of this study was to investigate the potential EMI from one such shoulder massage machine on implantable cardiac devices. We measured the distribution profile of the magnetic field intensity around the massage machine. Furthermore, we performed an inhibition test and an asynchronous test on an implantable cardiac pacemaker using the standardized Irnich human body model. We examined the events on an implantable cardioverter-defibrillator (ICD) using a pacemaker programmer while the massage machine was in operation. The magnetic field distribution profile exhibited a peak intensity of 212 (A/m) in one of the solenoid coils. The maximal interference distance between the massage machine and the implantable cardiac pacemaker was 28 cm. Ventricular fibrillation was induced when the massage machine was brought near the electrode of the ICD and touched the Irnich human body model. It is necessary to provide a "don't use" warning on the box or the exterior of the massage machines or in the user manuals and to caution patients with implanted pacemakers about the dangers and appropriate usage of massage machines.

  1. Investigation of Mechanical and Electromagnetic Interference Shielding Properties of Nickel-CFRP Textile Composites

    Science.gov (United States)

    Tugirumubano, Alexandre; Vijay, Santhiyagu Joseph; Go, Sun Ho; Kwac, Lee Ku; Kim, Hong Gun

    2018-04-01

    The most common materials used for electromagnetic interference shielding are metals and their alloys. However, those materials are heavy and highly reflective. In order to eliminate or reduce the intensity of wave radiation in their working environment, lightweight materials that have interference shielding properties are needed. In this paper, nickel wire mesh yarns (warps) were woven into carbon fibers-reinforced plastic yarns (wefts) to produce metal-carbon textile composite materials. The plain weave and 2/2 twill weave techniques were used, and the woven fabrics were laminated to manufacture experimental test samples. The nickel, which has high magnetic permeability and good electric conductivity, and carbon fibers, which have good electrical, thermal and mechanical properties, were used together to achieve the desired properties. The shielding effectiveness of each sample was investigated using a network analyzer connected with coaxial transmission line test in accordance with ASTM 4935-99 standard, with the frequencies ranging from 500 MHz to 1.5 GHz. Here, the plain weave structure showed higher shielding effectiveness than twill weave. The absorption losses for both materials were relatively greater than reflection losses. In reference to the orientation of wire mesh yarns about the loading axis, the tensile strengths in the transversal direction were 19.04 and 16.34% higher than the tensile strengths in longitudinal direction for plain weave and twill weave, respectively. The fractography analysis with SEM showed a ductile fracture of wire mesh and brittle fracture of epoxy matrix and carbon fibers.

  2. Investigation of Mechanical and Electromagnetic Interference Shielding Properties of Nickel-CFRP Textile Composites

    Science.gov (United States)

    Tugirumubano, Alexandre; Vijay, Santhiyagu Joseph; Go, Sun Ho; Kwac, Lee Ku; Kim, Hong Gun

    2018-05-01

    The most common materials used for electromagnetic interference shielding are metals and their alloys. However, those materials are heavy and highly reflective. In order to eliminate or reduce the intensity of wave radiation in their working environment, lightweight materials that have interference shielding properties are needed. In this paper, nickel wire mesh yarns (warps) were woven into carbon fibers-reinforced plastic yarns (wefts) to produce metal-carbon textile composite materials. The plain weave and 2/2 twill weave techniques were used, and the woven fabrics were laminated to manufacture experimental test samples. The nickel, which has high magnetic permeability and good electric conductivity, and carbon fibers, which have good electrical, thermal and mechanical properties, were used together to achieve the desired properties. The shielding effectiveness of each sample was investigated using a network analyzer connected with coaxial transmission line test in accordance with ASTM 4935-99 standard, with the frequencies ranging from 500 MHz to 1.5 GHz. Here, the plain weave structure showed higher shielding effectiveness than twill weave. The absorption losses for both materials were relatively greater than reflection losses. In reference to the orientation of wire mesh yarns about the loading axis, the tensile strengths in the transversal direction were 19.04 and 16.34% higher than the tensile strengths in longitudinal direction for plain weave and twill weave, respectively. The fractography analysis with SEM showed a ductile fracture of wire mesh and brittle fracture of epoxy matrix and carbon fibers.

  3. Low risk of electromagnetic interference between smartphones and contemporary implantable cardioverter defibrillators.

    Science.gov (United States)

    Burri, Haran; Mondouagne Engkolo, Louis Paulin; Dayal, Nicolas; Etemadi, Abdul; Makhlouf, Anne-Marie; Stettler, Carine; Trentaz, Florence

    2016-05-01

    Manufacturers of implantable cardioverter defibrillators (ICDs) recommend that cell phones be maintained at a distance of ∼15 cm from the implanted device in order to avoid risk of dysfunction due to electromagnetic interference (EMI). Data relating to this issue are outdated and do not reflect modern technology. Our aim was to evaluate whether EMI is still an issue with contemporary ICDs and smartphones. Consecutive patients implanted with a wireless-enabled ICD were tested for potential interference with two models of recent 4G smartphones in conditions intended to maximize risk of EMI. A magnet effect (due to the phone speakers) was tested by placing the smartphones in the standby mode directly over the ICD generator. The presence of EMI artefacts on the real-time electrograms was evaluated by placing the smartphones in the standby, dialling, and operating modes directly over the generator casing and over the parasternal region in the vicinity of the ventricular lead. A total of 63 patients equipped with 29 different models of single, dual, or biventricular ICDs from five major manufacturers were included. None of the patients showed any evidence of interference with the smartphones during any of the 882 tests. The risk of EMI between modern smartphones and contemporary ICDs is low. This is probably due to the filters incorporated in the ICDs and low emission by the phones, as well as the small size of the magnets in the smartphones tested. NCT02330900 (http://www.clinicaltrials.gov). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  4. New Definitions of Electromagnetic Screening of Cases in Front of Radiates Interferences

    Science.gov (United States)

    Garcia Perez, Luis Gines

    Electromagnetic shielding enclosures are simulated in this PhD thesis. Metallic enclosures with a frontal aperture have been implemented and shielding effectiveness has been calculated in frequency and time domains. The CST Microwave Studio application has been used, and necessary electromagnetic shielding measurements have been implemented in order to confirm the simulated results. An anechoic chamber and the network vector analyser ZVA 67 R&S have been employed. There were different set-ups that consist on two shielding enclosures with different apertures on their frontal walls, as well as an electric and a magnetic probes, and an external log-periodic antenna. The electromagnetic field shielding of enclosures against radiated interferences, and its study in the frequency and time domains requires to determine specific parameters for the measurement of the shielding effectiveness (SE). With this target recently it has been essayed indicators based on the peak reduction of electric and magnetic fields and the energy density in the time domain. Although many papers have been published with numeric simulations, rarely real measures in laboratory have been published. In the first part of this study, some important theoretical concepts have been explained, as the high intensity penetration of radiated fields in enclosures with apertures, several ways to define the shielding effectiveness, analytic formulations and different parameters among other concepts, in the frequency and time domains. Then, the system is defined, as from the implementations for simulations and calculations in CST Microwave Studio point of view, as from the set-ups implemented in laboratory point of view. In this section the features and utilization of the network vector analyser ZVA 67 R&S;, anechoic chamber design and dimensions, log-periodic antenna features, and all the different probes, enclosures and apertures employed have been detailed. After de system definition simulated and measured

  5. BMFO-PVDF electrospun fiber based tunable metamaterial structures for electromagnetic interference shielding in microwave frequency region

    Science.gov (United States)

    Revathi, Venkatachalam; Dinesh Kumar, Sakthivel; Subramanian, Venkatachalam; Chellamuthu, Muthamizhchelvan

    2015-11-01

    Metamaterial structures are artificial structures that are useful in controlling the flow of electromagnetic radiation. In this paper, composite fibers of sub-micron thickness of barium substituted magnesium ferrite (Ba0.2Mg0.8Fe2O4) - polyvinylidene fluoride obtained by electrospinning is used as a substrate to design electromagnetic interference shielding structures. While electrospinning improves the ferroelectric properties of the polyvinylidene fluoride, the presence of barium magnesium ferrite modifies the magnetic property of the composite fiber. The dielectric and magnetic properties at microwave frequency measured using microwave cavity perturbation technique are used to design the reflection as well as absorption based tunable metamaterial structures for electromagnetic interference shielding in microwave frequency region. For one of the structures, the simulation indicates that single negative metamaterial structure becomes a double negative metamaterial under the external magnetic field.

  6. Electromagnetic interference-aware transmission scheduling and power control for dynamic wireless access in hospital environments.

    Science.gov (United States)

    Phunchongharn, Phond; Hossain, Ekram; Camorlinga, Sergio

    2011-11-01

    We study the multiple access problem for e-Health applications (referred to as secondary users) coexisting with medical devices (referred to as primary or protected users) in a hospital environment. In particular, we focus on transmission scheduling and power control of secondary users in multiple spatial reuse time-division multiple access (STDMA) networks. The objective is to maximize the spectrum utilization of secondary users and minimize their power consumption subject to the electromagnetic interference (EMI) constraints for active and passive medical devices and minimum throughput guarantee for secondary users. The multiple access problem is formulated as a dual objective optimization problem which is shown to be NP-complete. We propose a joint scheduling and power control algorithm based on a greedy approach to solve the problem with much lower computational complexity. To this end, an enhanced greedy algorithm is proposed to improve the performance of the greedy algorithm by finding the optimal sequence of secondary users for scheduling. Using extensive simulations, the tradeoff in performance in terms of spectrum utilization, energy consumption, and computational complexity is evaluated for both the algorithms.

  7. Easily fabricated and lightweight PPy/PDA/AgNW composites for excellent electromagnetic interference shielding.

    Science.gov (United States)

    Wang, Yan; Gu, Fu-Qiang; Ni, Li-Juan; Liang, Kun; Marcus, Kyle; Liu, Shu-Li; Yang, Fan; Chen, Jin-Ju; Feng, Zhe-Sheng

    2017-11-30

    Conductive polymer composites (CPCs) containing nanoscale conductive fillers have been widely studied for their potential use in various applications. In this paper, polypyrrole (PPy)/polydopamine (PDA)/silver nanowire (AgNW) composites with high electromagnetic interference (EMI) shielding performance, good adhesion ability and light weight are successfully fabricated via a simple in situ polymerization method followed by a mixture process. Benefiting from the intrinsic adhesion properties of PDA, the adhesion ability and mechanical properties of the PPy/PDA/AgNW composites are significantly improved. The incorporation of AgNWs endows the functionalized PPy with tunable electrical conductivity and enhanced EMI shielding effectiveness (SE). By adjusting the AgNW loading degree in the PPy/PDA/AgNW composites from 0 to 50 wt%, the electrical conductivity of the composites greatly increases from 0.01 to 1206.72 S cm -1 , and the EMI SE of the composites changes from 6.5 to 48.4 dB accordingly (8.0-12.0 GHz, X-band). Moreover, due to the extremely low density of PPy, the PPy/PDA/AgNW (20 wt%) composites show a superior light weight of 0.28 g cm -3 . In general, it can be concluded that the PPy/PDA/AgNW composites with tunable electrical conductivity, good adhesion properties and light weight can be used as excellent EMI shielding materials.

  8. Fabrication and electromagnetic interference shielding effectiveness of polymeric composites filled with silver-coated microorganism cells

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Mingming, E-mail: lan_mingming@163.com [College of Mechanical and Electrical Engineering, Henan Agricultural University, Zhengzhou 450002 (China); Zhang, Deyuan; Cai, Jun; Hu, Yanyan; Yuan, Liming [Bionic and Micro/Nano/Bio Manufacturing Technology Research Center, School of Mechanical Engineering and Automation, Beihang University, Beijing 100191 (China)

    2014-07-01

    In this paper, helical silver-coated Spirulina cells were used as conductive fillers for the fabrication of polymeric composites. The morphology and composition of the coated Spirulina cells were analyzed with scanning electron microscope and energy dispersive X-ray spectrometer. The densities of silver-coated Spirulina cells were measured using the standard Archimedes method with distilled water. The electrical resistivity was measured by four-probe technique using ammeter and voltmeter whereas electromagnetic interference shielding effectiveness was measured by four-port method using vector network analyzer and coaxial-airline sample holder. The results showed that the silver-coated Spirulina cells with different coating thickness were lightweight fillers compared to the other typical conductive particles. The polymeric composites could achieve good conductivity at the lower content of silver-coated Spirulina cells owing to their helical shape. The shielding effectiveness of polymeric composites had a strong dependence on their conductivity. At the coating thickness of 0.96 μm and the content of 40 vol%, the shielding effectiveness could reach above 74.3 dB in entire test wave band.

  9. Novel Frequency Swapping Technique for Conducted Electromagnetic Interference Suppression in Power Converter Applications

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2016-12-01

    Full Text Available Quasi-resonant flyback (QRF converters have been widely applied as the main circuit topology in power converters because of their low cost and high efficiency. Conventional QRF converters tend to generate higher average conducted electromagnetic interference (EMI in the low-frequency domain due to the switching noise generated by power switches, resulting in the fact they can exceed the EMI standards of the European Standard 55022 Class-B emission requirements. The presented paper develops a novel frequency swapping control method that spreads spectral energy to reduce the amplitude of sub-harmonics, thereby lowering average conducted EMI in the low-frequency domain. The proposed method is implemented in a control chip, which requires no extra circuit components and adds zero cost. The proposed control method is verified using a 24 W QRF converter. Experimental results reveals that conducted EMI has been reduced by approximately 13.24 dBμV at 498 kHz compared with a control method without the novel frequency swapping technique. Thus, the proposed method can effectively improve the flyback system to easily meet the CISPR 22/EN55022 standards.

  10. Electrical conductivity and electromagnetic interference shielding characteristics of multiwalled carbon nanotube filled polyacrylate composite films

    International Nuclear Information System (INIS)

    Li Yong; Chen Changxin; Zhang Song; Ni Yuwei; Huang Jie

    2008-01-01

    Multiwalled carbon nanotubes (MWCNTs) were homogeneously dispersed in pure acrylic emulsion by ultrasonication to prepare MWCNT/polyacrylate composites applied on building interior wall for electromagnetic interference (EMI) shielding applications. The structure and surface morphology of the MWCNTs and MWCNT/polyacrylate composites were studied by field emission scanning microscopy (FESEM) and transmission electron microscopy (TEM). The electrical conductivity at room temperature and EMI shielding effectiveness (SE) of the composite films on concrete substrate with different MWCNT loadings were investigated and the measurement of EMI SE was carried out in two different frequency ranges of 100-1000 MHz (radio frequency range) and 8.2-12.4 GHz (X-band). The experimental results show that a low mass concentration of MWCNTs could achieve a high conductivity and the EMI SE of the MWCNT/polyacrylate composite films has a strong dependence on MWCNTs content in both two frequency ranges. The SE is higher in X-band than that in radio frequency range. For the composite films with 10 wt.% MWCNTs, the EMI SE of experiment agrees well with that of theoretical prediction in far field

  11. Electromagnetic interference shielding with Portland cement paste containing carbon materials and processed fly ash

    Directory of Open Access Journals (Sweden)

    Zornoza, E.

    2010-12-01

    Full Text Available The study described in this article explored the effect of adding different types of carbon materials (graphite powder and three types of carbon fibre, fly ash (with 5.6%, 15.9% and 24.3% Fe2O3, and a mix of both on electromagnetic interference (EMI shielding in Portland cement pastes. The parameters studied included the type and aspect ratio of the carbonic material, composite material thickness, the frequency of the incident electromagnetic radiation and the percentage of the magnetic fraction in the fly ash. The findings showed that the polyacrylonitrile-based carbon fibres, which had the highest aspect ratio, provided more effective shielding than any of the other carbon materials studied. Shielding was more effective in thicker specimens and at higher radiation frequencies. Raising the magnetic fraction of the fly ash, in turn, also enhanced paste shielding performance. Finally, adding both carbon fibre and fly ash to the paste resulted in the most effective EMI shielding as a result of the synergies generated.

    En el presente trabajo se investiga la influencia de la adición de diferentes tipos de materiales carbonosos (polvo de grafito y 3 tipos de fibra de carbono, de una ceniza volante con diferentes contenidos de fase magnética (5,6%, 15,9% y 24,3% de Fe2O3 y de una mezcla de ambos, sobre la capacidad de apantallar interferencias electromagnéticas de pastas de cemento Pórtland. Entre los parámetros estudiados se encuentra: el tipo de material carbonoso, la relación de aspecto del material carbonoso, el espesor del material compuesto, la frecuencia de la radiación electromagnética incidente y el porcentaje de fracción magnética en la ceniza volante. Los resultados obtenidos indican que entre los materiales carbonosos estudiados son las fibras de carbono basadas en poliacrilonitrilo con una mayor relación de aspecto las que dan mejores resultados de apantallamiento. Al aumentar

  12. Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

    Science.gov (United States)

    Bicket, Mark C; Hanna, George M

    2016-02-01

    Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

  13. Evaluating Electromagnetic Interference of Communication Devices with Root ZX Mini Apex Locator

    Directory of Open Access Journals (Sweden)

    Marzieh Shafieibavani

    2016-01-01

    Full Text Available Introduction: The correct determination of working length is a critical factor in the success of endodontic treatment. Nowadays, the electronic apex locators (EALs is more used because of their ease of use, high accuracy, and the uncertainty of other methods. Because EALs use the electronic method, it is likely that electromagnetic waves (EMWs affect their performance. This study aims to investigate the possibility of this interference. Materials and Methods: The visual canal length (CL of 12 maxillary incisors (Vertucci’s type I was measured with a K-file and magnifying glass. Root ZX mini apex locator is used to measure CL in the absence/presence of EMWs in both the second (2G and third generations (3G of mobile communication network at the mode of ringing and conversation at direct contact and the distances of 25 and 50 cm. Results: The mean CL at presence of EMWs in all conditions and distances (by removing the conversation with 2G at direct contact group were not significantly difference with CL and EAL and absence of investigated EMWs group (Repeated-Measures Analysis of Variance (ANOVA, P = 0.083. The indicator of EAL were unstable on apex sign at least 5 seconds for 5 teeth (41.7% of samples in conversation with 2G at the direct contact group. Conclusion: EMWs of 2G and 3G not causes malfunctions of the Root ZX mini apex locator except conversation with 2G at the direct contact.

  14. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site.

    Science.gov (United States)

    Fetter, J G; Benditt, D G; Stanton, M S

    1996-08-01

    This study was designed to determine the susceptibility of an implanted cardioverter-defibrillator to electromagnetic interference in an electrically hostile work site environment, with the ultimate goal of allowing the patient to return to work. Normal operation of an implanted cardioverter-defibrillator depends on reliable sensing of the heart's electrical activity. Consequently, there is concern that external electromagnetic interference from external sources in the work place, especially welding equipment or motor-generator systems, may be sensed and produce inappropriate shocks or abnormal reed switch operation, temporarily suspending detection of ventricular tachycardia or ventricular fibrillation. The effects of electromagnetic interference on the operation of one type of implantable cardioverter-defibrillator (Medtronic models 7217 and 7219) was measured by using internal event counter monitoring in 10 patients operating arc welders at up to 900 A or working near 200-hp motors and 1 patient close to a locomotive starter drawing up to 400 A. The electromagnetic interference produced two sources of potential interference on the sensing circuit or reed switch operation, respectively: 1) electrical fields with measured frequencies up to 50 MHz produced by the high currents during welding electrode activation, and 2) magnetic fields produced by the current in the welding electrode and cable. The defibrillator sensitivity was programmed to the highest (most sensitive) value: 0.15 mV (model 7219) or 0.3 mV (model 7217). The ventricular tachycardia and ventricular fibrillation therapies were temporarily turned off but the detection circuits left on. None of the implanted defibrillators tested were affected by oversensing of the electric field as verified by telemetry from the detection circuits. The magnetic field from 225-A welding current produced a flux density of 1.2 G; this density was not adequate to close the reed switch, which requires approximately 10 G

  15. Application of chaotic pulse width modulation control for suppressing electromagnetic interference in a half-bridge converter

    Directory of Open Access Journals (Sweden)

    Yuhong Song

    2014-08-01

    Full Text Available It was proposed in the former research that chaos control can be used to suppress electromagnetic interference (EMI in DC–DC converters. Analysis on a half-bridge converter is detailed in this study. Here, the practical example of the power supply of personal computers is given to show that, with an external chaotic signal to a pulse width modulation control circuit, the proposed approach can reduce EMI by reducing the amplitudes of power signals such as transformer current and output inductor currents at multiples of fundamental frequency.

  16. Fast electromagnetic characterization of integrated circuit passive isolation structures based on interference blocking

    NARCIS (Netherlands)

    Grau Novellas, M.; Serra, R.; Rose, Matthias

    2017-01-01

    An early characterization of integrated circuit passive isolation structures is crucial to predict their performance and effectiveness in minimizing substrate coupling. In this paper, an electromagnetic (EM) modeling methodology is proposed, which can be applied to different types of isolation

  17. Modifying a Commercial Centrifuge to Reduce Electromagnetic Interference and Evaluating Functionality of Ultrasound Equipment

    Science.gov (United States)

    Greening, Gage J.

    2016-01-01

    The Project Management and Engineering Branch (SF4) supports the Human Health and Performance Directorate (HH&P) and is responsible for developing and supporting human systems hardware for the International Space Station (ISS). When a principal investigator's (PI) medical research project on the ISS is accepted, SF4 develops the necessary hardware and software to transport to the ISS. The two projects I primarily worked on were the centrifuge and ultrasound projects. Centrifuge: One concern with spacecraft such as the ISS is electromagnetic interference (EMI) from onboard equipment, typically from radio waves (frequencies of 3 kHz to 300 GHz), which can negatively affect nearby circuitry. Standard commercial centrifuges produce EMI above safety limits, so my task was to help reduce EMI production from this equipment. Two centrifuges were tested: one unmodified as a control and one modified. To reduce EMI below safety limits, one centrifuge was modified to become a Faraday shield, in which significant electrical contact was made between all regions of the centrifuge housing. This included removing non-conductive paint, applying conductive fabric to the lid and foam sealer, adding a 10,000 µF decoupling capacitor across the power supply, and adding copper adhesive-mount gaskets to the housing interior. EMI testing of both centrifuges was performed in the EMI/EMC Control Test and Measurement Facility. EMI for both centrifuges was below safety limits for frequencies between 10 MHz and 15 GHz (pass); however, between 14 kHz and 10 MHz, EMI for the unmodified centrifuge exceeded safety limits (fail) as expected. Alternatively, for the modified centrifuge with the Faraday shield, EMI was below the safely limit of 55 dBµV/m for electromagnetic frequencies between 14 kHz and 10 MHz. This result indicates our modifications were successful. The successful EMI test allowed us to communicate with the vendor what modifications they needed to make to their commercial unit to

  18. The Potential of Coconut Shell Powder (CSP) and Coconut Shell Activated Carbon (CSAC) Composites as Electromagnetic Interference (EMI) Absorbing Material

    International Nuclear Information System (INIS)

    Siti Nurbazilah Abdul Jabal; Seok, Y.B.; Hoon, W.F.

    2016-01-01

    Agriculture waste is potentially useful as an alternative material to absorb and attenuate electromagnetic interference (EMI). This research highlights the use of coconut shell powder (CSP) and coconut shell activated carbon (CSAC) as raw materials with epoxy resin and amine hardener composite to absorb microwave signals over frequency of 1 - 8 GHz. In order to investigate the suitability of these raw materials as EMI absorbing material, carbon composition of the raw materials is determined through CHNS Elemental Analysis. The surface morphology of the raw materials in term of porosity is investigated by using TM3000 Scanning Electron Microscope (SEM). The complex permittivity of the composites is determined by using high temperature dielectric probe in conjunction with Network Analyzer. From the result, the Carbon% of CSP and CSAC is 46.70 % and 84.28 % respectively. In term of surface morphology, the surface porosity of CSP and CSAC is in the range of 2 μm and 1 μm respectively. For the dielectric properties, the dielectric constant and the dielectric loss factor for CSP and CSAC is 4.5767 and 64.8307 and 1.2144 and 13.8296 respectively. The materials more potentially useful as substitute materials for electromagnetic interference (EMI) absorbing are discussed. (author)

  19. Electrical conductivity and electromagnetic interference shielding of epoxy nanocomposite foams containing functionalized multi-wall carbon nanotubes

    Science.gov (United States)

    Li, Jiantong; Zhang, Guangcheng; Zhang, Hongming; Fan, Xun; Zhou, Lisheng; Shang, Zhengyang; Shi, Xuetao

    2018-01-01

    Epoxy/functionalized multi-wall carbon nanotube (EP/F-MWCNT) microcellular foams were fabricated through a supercritical CO2 (scCO2) foaming method. MWCNTs with carboxylation treatment were disentangled by using alpha-zirconium phosphate (ZrP) assisting dispersion method and functionalized with sulfanilamide. The F-MWCNTs were redispersed in acetone for mixing with epoxy resins to prepare nanocomposites. It was found that the dispersion of MWCNTs could be improved, thus heterogeneous nucleation effect of F-MWCNTs took place effectively during the foaming process, resulting in the formation of microcellular structure with larger cell density and smaller cell size. The volume conductivity and electromagnetic interference shielding performance of foamed EP/F-MWCNT nanocomposites were studied. When the F-MWCNT addition was 5 wt%, the conductivity of the foamed EP/F-MWCNT nanocomposites was 3.02 × 10-4 S/cm and the EMI shielding effectiveness (SE) reached 20.5 dB, significantly higher than the corresponding results of nanocomposite counterparts, indicating that introducing microcellular structure in EP/F-MWCNT nanocomposites would beneficial to improve their electrical conductivity and electromagnetic interference shielding performance.

  20. Assessing effects of cholera vaccination in the presence of interference.

    Science.gov (United States)

    Perez-Heydrich, Carolina; Hudgens, Michael G; Halloran, M Elizabeth; Clemens, John D; Ali, Mohammad; Emch, Michael E

    2014-09-01

    Interference occurs when the treatment of one person affects the outcome of another. For example, in infectious diseases, whether one individual is vaccinated may affect whether another individual becomes infected or develops disease. Quantifying such indirect (or spillover) effects of vaccination could have important public health or policy implications. In this article we use recently developed inverse-probability weighted (IPW) estimators of treatment effects in the presence of interference to analyze an individually-randomized, placebo-controlled trial of cholera vaccination that targeted 121,982 individuals in Matlab, Bangladesh. Because these IPW estimators have not been employed previously, a simulation study was also conducted to assess the empirical behavior of the estimators in settings similar to the cholera vaccine trial. Simulation study results demonstrate the IPW estimators can yield unbiased estimates of the direct, indirect, total, and overall effects of vaccination when there is interference provided the untestable no unmeasured confounders assumption holds and the group-level propensity score model is correctly specified. Application of the IPW estimators to the cholera vaccine trial indicates the presence of interference. For example, the IPW estimates suggest on average 5.29 fewer cases of cholera per 1000 person-years (95% confidence interval 2.61, 7.96) will occur among unvaccinated individuals within neighborhoods with 60% vaccine coverage compared to neighborhoods with 32% coverage. Our analysis also demonstrates how not accounting for interference can render misleading conclusions about the public health utility of vaccination. © 2014, The International Biometric Society.

  1. The influence of electromagnetic interference and ionizing radiation on cardiac pacemakers

    International Nuclear Information System (INIS)

    Salmi, J.; Malmivuo, J.A.V.

    1990-01-01

    Adverse effects of the ionizing and non-ionizing electromagnetic fields on five pacemaker models have been tested. The study consisted of three parts: 1. measurement of magnetic fields in a radiotherapy room (microtron MM14), 2. the application of non-ionizing electromagnetic fields on pacemakers in a test laboratory (1 ... 1000 μT, 10 ... 10 000 Hz), and 3. the application of ionizing radiation of different types of radiotherapy devices on the pacemakers. The magnetic field strength in the microtron treatment room was found to be under 7.5 μT, which is one order of magnitude lower than the tolerance level obtained for the pacemakers in the test laboratory. All the tested pacemakers tolerated the ionizing radiation dose levels (less than 60 Gy) which are used in the radiotherapy. (orig.) [de

  2. Designing of epoxy composites reinforced with carbon nanotubes grown carbon fiber fabric for improved electromagnetic interference shielding

    Directory of Open Access Journals (Sweden)

    B. P. Singh

    2012-06-01

    Full Text Available In this letter, we report preparation of strongly anchored multiwall carbon nanotubes (MWCNTs carbon fiber (CF fabric preforms. These preforms were reinforced in epoxy resin to make multi scale composites for microwave absorption in the X-band (8.2-12.4GHz. The incorporation of MWCNTs on the carbon fabric produced a significant enhancement in the electromagnetic interference shielding effectiveness (EMI-SE from −29.4 dB for CF/epoxy-composite to −51.1 dB for CF-MWCNT/epoxy multiscale composites of 2 mm thickness. In addition to enhanced EMI-SE, interlaminar shear strength improved from 23 MPa for CF/epoxy-composites to 50 MPa for multiscale composites indicating their usefulness for making structurally strong microwave shields.

  3. Characterization and Suppression of the Electromagnetic Interference Induced Phase Shift in the JLab FEL Photo - Injector Advanced Drive Laser System

    Energy Technology Data Exchange (ETDEWEB)

    F. G. Wilson, D. Sexton, S. Zhang

    2011-09-01

    The drive laser for the photo-cathode gun used in the JLab Free Electron Laser (FEL) facility had been experiencing various phase shifts on the order of tens of degrees (>20{sup o} at 1497 MHz or >40ps) when changing the Advanced Drive Laser (ADL) [2][3][4] micro-pulse frequencies. These phase shifts introduced multiple complications when trying to setup the accelerator for operation, ultimately inhibiting the robustness and overall performance of the FEL. Through rigorous phase measurements and systematic characterizations, we determined that the phase shifts could be attributed to electromagnetic interference (EMI) coupling into the ADL phase control loop, and subsequently resolved the issue of phase shift to within tenths of a degree (<0.5{sup o} at 1497 MHz or <1ps). The diagnostic method developed and the knowledge gained through the entire process will prove to be invaluable for future designs of similar systems.

  4. Technical basis for evaluating electromagnetic and radio-frequency interference in safety-related I ampersand C systems

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.

    1994-04-01

    This report discusses the development of the technical basis for the control of upsets and malfunctions in safety-related instrumentation and control (I ampersand C) systems caused by electromagnetic and radio-frequency interference (EMI/RFI) and power surges. The research was performed at the Oak Ridge National Laboratory (ORNL) and was sponsored by the USNRC Office of Nuclear Regulatory Research (RES). The motivation for research stems from the safety-related issues that need to be addressed with the application of advanced I ampersand C systems to nuclear power plants. Development of the technical basis centered around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems known to be the source(s) of EMI/RFI and power surges. First, good EMC design and installation practices need to be established to control the impact of interference sources on nearby circuits and systems. These EMC good practices include circuit layouts, terminations, filtering, grounding, bonding, shielding, and adequate physical separation. Second, an EMI/RFI test and evaluation program needs to be established to outline the tests to be performed, the associated test methods to be followed, and carefully formulated acceptance criteria based on the intended environment to ensure that the circuit or system under test meets the recommended guidelines. Third, a program needs to be developed to perform confirmatory tests and evaluate the surge withstand capability (SWC) and of I ampersand C equipment connected to or installed in the vicinity of power circuits within the nuclear power plant. By following these three steps, the design and operability of safety-related I ampersand C systems against EMI/RFI and power surges can be evaluated, acceptance criteria can be developed, and appropriate regulatory guidance can be provided

  5. Measurements, characteristics, and origin of new electromagnetic interference on magnetocardiographic measurements

    International Nuclear Information System (INIS)

    Gu Hong-Fang; Cai Wen-Yan; Wei Yu-Ke; Liu Zheng-Hao; Wang Qian; Wang Yue; Dai Yuan-Dong; Ma Ping

    2012-01-01

    In order to eliminate the influence of the large-amplitude magnetic field noise that has complicated magnetocardiographic studies since October 2009, we have performed high-accuracy measurement of the environmental magnetic field noise in the vicinity of Beijing Subway Line 4 using a three-component height T c radio frequency (rf) superconducting quantum interference device (SQUID). By analysing the spatial form and other characteristics of the time and the frequency domains and by calculating the circumferential magnetic field distribution based on a duel-end feeding system model, we reach the following conclusions: (i) the main source of magnetic field noise is the magnetic field generated by the subway trains, and (ii) the magnetic field interference results mainly from the imbalance between traction current and return rail current that is caused by the leakage current. (general)

  6. The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators

    International Nuclear Information System (INIS)

    Venselaar, J.L.M.

    1985-01-01

    Eight cardiac pacemakers were irradiated in a cobalt-60 beam. Two out of six demand-type pacemakers showed an alarming decrease in pulse repetition frequency when irradiated to dose levels that are used in radiotherapy. Two modern programmable pacemakers showed a failure at a dose of 97 and 147 Gy, respectively. The dose levels at which these failures occurred were low enough to recommend that cardiac pacemakers should always be kept outside the radiation beam. The signals induced by electromagnetic interference (EMI) from two linear accelerators were measured using a simulation model of a pacemaker. In the laboratory, 22 modern-type pacemakers were tested with these signals to determine the sensitivity for the electromagnetic fields in the treatment rooms. It was observed that an inhibition of one pacemaker pulse was to be expected on one of the two linear accelerators when switching the machine on and off. No permanent effects were found. These findings resulted in the recommendation in our department not to use this treatment machine for radiation therapy of pacemaker-bearing patients. (orig.)

  7. Light and Strong Hierarchical Porous SiC Foam for Efficient Electromagnetic Interference Shielding and Thermal Insulation at Elevated Temperatures.

    Science.gov (United States)

    Liang, Caiyun; Wang, Zhenfeng; Wu, Lina; Zhang, Xiaochen; Wang, Huan; Wang, Zhijiang

    2017-09-06

    A novel light but strong SiC foam with hierarchical porous architecture was fabricated by using dough as raw material via carbonization followed by carbothermal reduction with silicon source. A significant synergistic effect is achieved by embedding meso- and nanopores in a microsized porous skeleton, which endows the SiC foam with high-performance electromagnetic interference (EMI) shielding, thermal insulation, and mechanical properties. The microsized skeleton withstands high stress. The meso- and nanosized pores enhance multiple reflection of the incident electromagnetic waves and elongate the path of heat transfer. For the hierarchical porous SiC foam with 72.8% porosity, EMI shielding can be higher than 20 dB, and specific EMI effectiveness exceeds 24.8 dB·cm 3 ·g -1 at a frequency of 11 GHz at 25-600 °C, which is 3 times higher than that of dense SiC ceramic. The thermal conductivity reaches as low as 0.02 W·m -1 ·K -1 , which is comparable to that of aerogel. The compressive strength is as high as 9.8 MPa. Given the chemical and high-temperature stability of SiC, the fabricated SiC foam is a promising candidate for modern aircraft and automobile applications.

  8. Thin and Flexible Fe-Si-B/Ni-Cu-P Metallic Glass Multilayer Composites for Efficient Electromagnetic Interference Shielding.

    Science.gov (United States)

    Zhang, Jijun; Li, Jiawei; Tan, Guoguo; Hu, Renchao; Wang, Junqiang; Chang, Chuntao; Wang, Xinmin

    2017-12-06

    Thin and flexible materials that can provide efficient electromagnetic interference (EMI) shielding are urgently needed, especially if they can be easily processed and withstand harsh environments. Herein, layer-structured Fe-Si-B/Ni-Cu-P metallic glass composites have been developed by simple electroless plating Ni-Cu-P coating on commercial Fe-Si-B metallic glasses. The 0.1 mm-thick composite shows EMI shielding effectiveness of 40 dB over the X-band frequency range, which is higher than those of traditional metals, metal oxides, and their polymer composites of larger thickness. Most of the applied electromagnetic waves are proved to be absorbed rather than bounced back. This performance originates from the combination of a superior soft magnetic property, excellent electrical conductivity, and multiple internal reflections from multilayer composites. In addition, the flexible composites also exhibit good corrosion resistance, high thermal stability, and excellent tensile strength, making them suitable for EMI shielding in harsh chemical or thermal environments.

  9. Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-III

    Directory of Open Access Journals (Sweden)

    Alesch François

    2003-05-01

    Full Text Available Abstract Background The purpose was to investigate mobile phone interference with implantable deep brain stimulators by means of 10 different 900 Mega Hertz (MHz and 10 different 1800 MHz GSM (Global System for Mobile Communications mobile phones. Methods All tests were performed in vitro using a phantom especially developed for testing with deep brain stimulators. The phantom was filled with liquid phantom materials simulating brain and muscle tissue. All examinations were carried out inside an anechoic chamber on two implants of the same type of deep brain stimulator: ITREL-III from Medtronic Inc., USA. Results Despite a maximum transmitted peak power of mobile phones of 1 Watt (W at 1800 MHz and 2 W at 900 MHz respectively, no influence on the ITREL-III was found. Neither the shape of the pulse form changed nor did single pulses fail. Tests with increased transmitted power using CW signals and broadband dipoles have shown that inhibition of the ITREL-III occurs at frequency dependent power levels which are below the emissions of GSM mobile phones. The ITREL-III is essentially more sensitive at 1800 MHz than at 900 MHz. Particularly the frequency range around 1500 MHz shows a very low interference threshold. Conclusion These investigations do not indicate a direct risk for ITREL-III patients using the tested GSM phones. Based on the interference levels found with CW signals, which are below the mobile phone emissions, we recommend similar precautions as for patients with cardiac pacemakers: 1. The phone should be used at the ear at the opposite side of the implant and 2. The patient should avoid carrying the phone close to the implant.

  10. Interference effects at photoionization of Rydberg atoms by a strong electromagnetic field

    International Nuclear Information System (INIS)

    Movsesyan, A.M.; Fedorov, M.V.

    1989-01-01

    The photoionization of Rydberg atoms in a strong electromagnetic field is considered. Degeneration of the levels with respect to the orbital moment, their Stark splitting and the possibility of resonant interaction with levels of lower energy are taken into account. The complex quasi-energies of the system, photoelectron spectrum in the limit of an infinite duration of interaction and the time dependence of the total ionization probability are found. It is shown that a narrowing of the quasi-energy levels occurs in a strong field. Against a background of the quasi- continuum the quasi-energy spectrum consists of more or less narrow levels. In this case the photoelectron spectrum acquires a multi-peak form. With increasing field strength the height of the peaks increases, whereas their width decreases. The ionization rate decreases with increasing field strength. The presence of a quasi-continuum is the cause of the partially non-exponential nature of the atomic disintegration

  11. Fabrication and electromagnetic interference shielding performance of open-cell foam of a Cu–Ni alloy integrated with CNTs

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Keju; Zhao, Huihui; Zhang, Jun; Chen, Jia; Dai, Zhendong, E-mail: zddai@nuaa.edu.cn

    2014-08-30

    Highlights: • Cu–Ni alloy open-cell foam integrated with CNTs was used for EMI shielding. • The composite was prepared by electroless, electro-, and electrophoretic deposition. • The main shielding mechanism was multiple reflections and absorptions of microwaves. • The composite had a porous structure, large surface area, and inherent permeability. - Abstract: A lightweight multi-layered electromagnetic interference (EMI) shielding material made of open-cell foam of a Cu–Ni alloy integrated with carbon nanotubes (CNTs) was prepared by electroless copper plating, then nickel electroplating, and finally electrophoretic deposition of CNTs. The foamed Cu–Ni–CNT composite comprises, from inside to outside, Cu, Ni, and CNT layers. Scanning electron microscopy, energy dispersive spectroscopy, and EMI tests were employed to characterize the morphology, composition, and EMI performance of the composite, respectively. The results indicated that the shielding effectiveness (SE) of the composite increased with increasing pore density (indicated as pores per inch (PPI)) and increasing thickness. A specimen with a PPI of 110 and a 1.5-mm thickness had a maximum SE of up to 54.6 dB, and a SE as high as 47.5 dB on average in the 8–12 GHz range. Integrating the inherent superiority of Cu, Ni, and CNTs, the porous structure of the composite can attenuate the incident electromagnetic microwaves by reflecting, scattering, and absorbing them between the metallic skeleton and the CNT layer. The multiple reflections and absorptions make it difficult for the microwaves to escape from the composite before being absorbed, thereby making the composite a potential shielding material.

  12. Remote-actuator used in environments for high electromagnetic interference; Actuador telecontrolado para ambientes de alta interferencia electromagnetica

    Energy Technology Data Exchange (ETDEWEB)

    Perez Abad, Carlos Alberto; Velazquez Hernandez, Jose Conrado; Montero Cervantes, Julio Cesar [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: caperez@iie.org.mx; jconrado@iie.org.mx; jcmc@iie.org.mx

    2010-11-15

    This article presents the design of an actuator telecontrolled used in environments of high electromagnetic interference, especially designed for high-power laboratories Comision Federal de Electricidad, LAPEM (Laboratorio de pruebas de equipos y materiales) basically the actuator is an electronic component in a series of hardware and software involved in short circuit tests performed LAPEM but because of its design can be used in any industry involving fire remotely due to the electromagnetic pollution caused by high currents and voltages involved in the tests, the means of communication between the actuator and programmable controller sequences (CPS) is optical fiber that ensures the integrity of the control signal that activates the device. We present the electronic modules that comprise it and the evidence and findings. [Spanish] En este articulo se presenta el diseno de un actuador telecontrolado utilizado en ambientes de alta interferencia electromagnetica, en especial fue disenado para los laboratorios de alta potencia del LAPEM (Laboratorio de pruebas de equipos y materiales), Comision Federal de Electricidad, basicamente el actuador es un componente electronico de una serie de hardware y software involucrados en las pruebas de corto circuito que realiza el LAPEM pero debido a su diseno puede ser utilizado en cualquier otra industria que involucre disparos en forma remota, debido a la contaminacion electromagnetica causada por las altas corrientes y voltajes involucradas en las pruebas, el medio de comunicacion entre el actuador y el Controlador programable de Secuencias (CPS) es fibra optica con esto se asegura la integridad de la senal de control que activa el dispositivo. Se presenta los modulos electronicos que lo componen asi como las pruebas y resultados obtenidos.

  13. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    Science.gov (United States)

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V; Hagan, Michael; Anscher, Mitchell

    2011-05-01

    To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading accuracy in the presence of wireless electromagnetic transponders inside a phantom. A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with/without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with/without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit. Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0

  14. Dependences of microstructure on electromagnetic interference shielding properties of nano-layered Ti3AlC2 ceramics.

    Science.gov (United States)

    Tan, Yongqiang; Luo, Heng; Zhou, Xiaosong; Peng, Shuming; Zhang, Haibin

    2018-05-21

    The microstructure dependent electromagnetic interference (EMI) shielding properties of nano-layered Ti 3 AlC 2 ceramics were presented in this study by comparing the shielding properties of various Ti 3 AlC 2 ceramics with distinct microstructures. Results indicate that Ti 3 AlC 2 ceramics with dense microstructure and coarse grains are more favourable for superior EMI shielding efficiency. High EMI shielding effectiveness over 40 dB at the whole Ku-band frequency range was achieved in Ti 3 AlC 2 ceramics by microstructure optimization, and the high shielding effectiveness were well maintained up to 600 °C. A further investigation reveals that only the absorption loss displays variations upon modifying microstructure by allowing more extensive multiple reflections in coarse layered grains. Moreover, the absorption loss of Ti 3 AlC 2 was found to be much higher than those of highly conductive TiC ceramics without layered structure. These results demonstrate that nano-layered MAX phase ceramics are promising candidates of high-temperature structural EMI shielding materials and provide insightful suggestions for achieving high EMI shielding efficiency in other ceramic-based shielding materials.

  15. Fabrication and evaluation of thin layer PVDF composites using MWCNT reinforcement: Mechanical, electrical and enhanced electromagnetic interference shielding properties

    Directory of Open Access Journals (Sweden)

    B. V. Bhaskara Rao

    2016-06-01

    Full Text Available Radar X-band electromagnetic interference shielding (EMS is one of the prime requirements for any air vehicle coating; with limitations on the balance between strength and thickness of the EMS material. Nanocomposite of multiwalled-carbon-nanotubes (MWCNT has been homogeneously integrated (0 – 9 wt% with polymer, poly (vinylidene fluoride, PVDF to yield 300 micron film. The PVDF + 9 wt% MWCNT sample of density 1.41 g/cm3 show specific shielding effectiveness (SSE of 17.7 dB/(g/cm3 (99.6% EMS, with maintained hardness and improved conductivity. With multilayer stacking (900 microns of these films of density 1.37 g/cm3, the sample showed increase in SSE to 23.3 dB/(g/cm3 (99.93% EMS. Uniform dispersion of MWCNTs in the PVDF matrix gives rise to increased conductivity in the sample beyond 5 wt% MWCNT reinforcement. The results are correlated to the hardness, reflection loss, absorption loss, percolation threshold, permittivity and the conductivity data. An extremely thin film with maximum EMS property is hence proposed.

  16. Electromagnetic interference shielding and thermal properties of non-covalently functionalized reduced graphene oxide/epoxy composites

    Directory of Open Access Journals (Sweden)

    Suman Chhetri

    2016-12-01

    Full Text Available Graphene oxide (GO was non-covalently functionalized using sulfanilic acid azocromotrop (SAC followed by hydrazine reduction to achieve SAC functionalized reduced GO (SAC-rGO. Fourier transform infrared spectra analysis and electrical conductivity measurements confirmed the successful functionlization and reduction of GO. The electrical conductivity of ~515 S•m−1 for SAC-rGO was recorded. The non-covalently functionalized reduced GO was subsequently dispersed in epoxy matrix at the loading level of 0.3 to 0.5 wt% to investigate its electromagnetic interference (EMI shielding properties. The morphological and structural characterization of the SAC-rGO/epoxy composites was carried out using X-ray diffraction and Transmission electron microscopy analysis, which revealed the good dispersion of SAC-rGO in the epoxy. The SAC-rGO/epoxy composites showed the EMI shielding of −22.6 dB at the loading of 0.5 wt% SAC-rGO. Dynamical mechanical properties of the composites were studied to establish the reinforcing competency of the SAC-rGO. The storage modulus of the composites was found to increase within the studied temperature. Thermal stability of pure epoxy and its composites were compared by selecting the temperatures at 10 and 50% weight loss, respectively.

  17. Testing of Common Electromagnetic Environments for Risk of Interference with Cardiac Pacemaker Function

    Directory of Open Access Journals (Sweden)

    Maria Tiikkaja

    2013-09-01

    Conclusions: Modern pacemakers are well shielded against external EMFs, and workers with a pacemaker can most often return to their previous work after having a pacemaker implanted. However, an appropriate risk assessment is still necessary after the implantation of a pacemaker, a change of its generator, or major modification of its programming settings.

  18. Hexavalent Chrome Free Coatings for Electronics; Electromagnetic Interference (EMI) Shielding Effectiveness (SE)

    Science.gov (United States)

    Kessel, Kurt R.

    2014-01-01

    The purpose of this testing is to determine the suitability of trivalent chromium conversion coatings that meet the requirements of MIL-DTL-5541, Type II, for use in applications where high-frequency electrical performance is important. This project will evaluate the ability of coated aluminum to form adequate EMI seals. Testing will assess performance of the trivalent chromium coatings against the known control hexavalent chromium MIL-DTL-5541 Type I Class 3 before and after they have been exposed to a set of environmental conditions. Performance will be assessed by evaluating shielding effectiveness (SE) test data from a variety of test samples comprised of different aluminum types and/or conversion coatings.

  19. Hexavalent Chrome Free Coatings for Electronics: Electromagnetic Interference (EMI) Shielding Effectiveness (SE)

    Science.gov (United States)

    Kessel, Kurt R.

    2016-01-01

    Determine the suitability of trivalent chromium conversion coatings that meet the requirements of MIL-DTL-5541, Type II, for use in applications where high-frequency electrical performance is important. Evaluate the ability of hexavalent chrome free pretreated aluminum to form adequate EMI seals, and maintain that seal while being subjected to harsh environmental conditions. Assess the performance of trivalent chromium pretreatments against a known control hexavalent chrome pretreatment before and after they have been exposed to a set of environmental conditions. It is known that environmental testing causes a decrease in shielding effectiveness when hexavalent chrome pretreatments are used (Alodine 1200s). Need to determine how shielding effectiveness will be affected with the use of hexavalent chrome free pretreatments. Performance will be assessed by evaluating shielding effectiveness (SE) test data from a variety of test samples comprised of different aluminum types and/or conversion coatings. The formation of corrosion will be evaluated between the mating surfaces and gasket to assess the corrosion resistant properties of the pretreatments, comparing the hexavalent control to the hexavalent chrome free pretreatments.

  20. Setups for in vitro assessment of RFID interference on pacemakers

    International Nuclear Information System (INIS)

    Mattei, E; Censi, F; Delogu, A; Ferrara, A; Calcagnini, G

    2013-01-01

    The aim of this study is to propose setups for in vitro assessment of RFID (radiofrequency identification) interference on pacemakers (PM). The voltage induced at the input stage of the PM by low-frequency (LF) and high-frequency (HF) RFID transmitters has been used to quantify the amount of the interference. A commercial PM was modified in order to measure the voltage at its input stage when exposed to a sinusoidal signal at 125 kHz and 13.56 MHz. At both frequencies, two antennas with different dimensions (diameter = 10 cm and 30 cm, respectively) were used to generate the interfering field, and the induced voltage was measured between the lead tip and the PM case (unipolar voltage), and between the tip and ring electrodes (bipolar voltage). The typical lead configurations adopted in similar studies or proposed by international standards, as well as lead paths closer to actual physiological implants were tested. At 125 kHz, the worst-case condition differs for the two antennas: the 10 cm antenna induced the highest voltage in the two-loop spiral configuration, whereas the 30 cm antenna in the 225 cm 2 loop configuration. At 13.56 MHz, the highest voltage was observed for both the antennas in the 225 cm 2 loop configuration. Bipolar voltages were found to be lower than the unipolar voltages induced in the same configurations, this difference being not as high as one could expect from theoretical considerations. The worst-case scenario, in terms of the induced voltage at the PM input stage, has been identified both for LF and HF readers, and for two sizes of transmitting antennas. These findings may provide the basis for the definition of a standard implant configuration and a lead path to test the EMI effects of LF and HF RFID transmitters on active implantable devices. (paper)

  1. Microwave processed bulk and nano NiMg ferrites: A comparative study on X-band electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Chandra Babu Naidu, K., E-mail: chandrababu954@gmail.com [Ceramic Composite Laboratory, Centre for Crystal Growth, SAS, VIT University, Vellore 632014, Tamilnadu (India); Madhuri, W., E-mail: madhuriw12@gmail.com [Ceramic Composite Laboratory, Centre for Crystal Growth, SAS, VIT University, Vellore 632014, Tamilnadu (India); IFW, Leibniz Institute for Solid State and Materials Research, Technische Universität Dresden, 01069 Dresden (Germany)

    2017-02-01

    Bulk and nano Ni{sub 1-x}Mg{sub x}Fe{sub 2}O{sub 4} (x = 0–1) samples were synthesized via microwave double sintering and microwave assisted hydrothermal techniques respectively. The diffraction pattern confirmed the formation of cubic spinel phases in case of both the ferrites. The larger bulk densities were achieved to the bulk than that of nano. In addition, a comparative study on X-band (8.4–12 GHz) electromagnetic interference shielding properties of current bulk and nanomaterials was elucidated. The results showed that the bulk Ni{sub 0.6}Mg{sub 0.4}Fe{sub 2}O{sub 4} composition revealed the highest total shielding efficiency (SE{sub T}) of ∼17 dB. In comparison, the shielding efficiency values of all bulk contents were higher than that of nano because of larger bulk densities. Moreover, the ac-electromagnetic parameters such as electrical conductivity (σ{sub ac}), the respective real (ε′ & μ′) and imaginary parts (ε″ & μ″) of complex permittivity and permeability were investigated as a function of gigahertz frequency. The bulk ferrites of x = 0.4 & 0.6 showed the high ε″ of 10.26 & 6.71 and μ″ of 3.65 & 3.09 respectively at 12 GHz which can work as promising microwave absorber materials. Interestingly, nanoferrites exhibited negative μ″ values at few frequencies due to geometrical effects which improves the microwave absorption. - Highlights: • Bulk and nano NiMg ferrites are prepared by microwave and hydrothermal method. • X-band EMI shielding properties are studied for both bulk and nano ferrites. • Bulk Ni{sub 0.6}Mg{sub 0.4}Fe{sub 2}O{sub 4} revealed the highest SE{sub T} of ∼17 dB at 8.4 GHz. • Bulk x = 0.4 & 0.6 showed the high ε″ and μ″ at 12 GHz for absorber applications.

  2. Non-ionizing electromagnetic exposure assessment and dosimetry

    International Nuclear Information System (INIS)

    Paulsson, L.E.

    1992-11-01

    A comprehensive literature survey of advancements in the area 'human exposure assessment and dosimetry' for the years 1988-1992 has been performed by the author and published elsewhere. In the present report that material has been complemented with a historical background and a thorough description of the physical principles behind the methods and techniques. The report covers strategies, principles, methods, limitations and future developments for the area of human exposure assessment and dosimetry of electromagnetic fields form extremely low frequencies up to and including microwaves

  3. Effects of electromagnetic interference on the functional usage of medical equipment by 2G/3G/4G cellular phones: A revie

    Directory of Open Access Journals (Sweden)

    Periyasamy M. Mariappan

    2016-09-01

    Full Text Available There has been an increase in the potential use of wireless devices in healthcare domain for a variety of reasons. The most commonly used device is the cellular phone, which emits strong electromagnetic energy affecting thereby the functionality of the vital medical equipment such as ventilators, ECG monitors, cardiac monitors, and defibrillators. This prompted the healthcare concerns to restrict the use of these phones in the proximity of critical and non-critical care medical equipment. Due to the developments made in the design of medical equipment to comply with the EMC standards, the restriction had been slowly laid off. Still, the researchers are concerned about the electromagnetic interference with medical devices by cellular phones in the healthcare domain and recommend for conducting continuous research to study their interaction with medical equipment. This paper overviews the certain investigations carried out in the recent years to study the electromagnetic interference between medical devices and 2G/3G/4G LTE cellular phones. During the initial development of cellular phones, the 2G cellular phones had caused more interference that affects the function and operation of some medical devices. The possibility of interference from 3G cellular phones with medical devices was considerably lower than the 2G phones, but still exists. Furthermore, almost all of the 4G phones have little to no interference with the medical devices. Currently, with the development of the medical devices industry, the current medical devices are designed to operate safely under any conditions of usage. Finally, a careful analysis would require statistics on the frequency of adverse events across the healthcare system, which apparently do not exist.

  4. Electromagnetism

    CERN Document Server

    Grant, Ian S

    1990-01-01

    The Manchester Physics Series General Editors: D. J. Sandiford; F. Mandl; A. C. Phillips Department of Physics and Astronomy, University of Manchester Properties of Matter B. H. Flowers and E. Mendoza Optics Second Edition F. G. Smith and J. H. Thomson Statistical Physics Second Edition F. Mandl Electromagnetism Second Edition I. S. Grant and W. R. Phillips Statistics R. J. Barlow Solid State Physics Second Edition J. R. Hook and H. E. Hall Quantum Mechanics F. Mandl Particle Physics Second Edition B. R. Martin and G. Shaw the Physics of Stars Second Edition A. C. Phillips Computing for Scient

  5. Electromagnetic interference shielding effectiveness of microcellular polyimide/in situ thermally reduced graphene oxide/carbon nanotubes nanocomposites

    Science.gov (United States)

    Yang, Hongli; Yu, Zhi; Wu, Peng; Zou, Huawei; Liu, Pengbo

    2018-03-01

    A simple and effective method was adopted to fabricate microcellular polyimide (PI)/reduced graphene oxide (GO)/multi-walled carbon nanotubes (MWCNTs) nanocomposites. Firstly, microcellular poly (amic acid) (PAA)/GO/MWCNTs nanocomposites were prepared through solvent evaporation induced phase separation. In this process, PAA and dibutyl phthalate (DBP) co-dissolved in N,N-dimethylacetamide (DMAc) underwent phase separation with DMAc evaporating, and DBP microdomains were formed in continuous PAA phase. Subsequently, PAA was thermally imidized and simultaneously GO was in situ reduced. After DBP was removed, the microcellular PI/reduced GO (RGO)/MWCNTs nanocomposites were finally obtained. When the initial filler loading was 8 wt%, the electrical conductivity of microcellular PI/RGO, PI/MWCNTs and PI/RGO/MWCNTs nanocomposites were 0.05, 0.02 and 1.87 S·m-1, respectively, and the electromagnetic interference (EMI) shielding efficiency (SE) of microcellular PI/RGO, PI/MWCNTs and PI/RGO/MWCNTs nanocomposites were 13.7-15.1, 13.0-14.3 and 16.6-18.2 dB, respectively. The synergistic effect between RGO and MWCNTs enhanced both the electrical conductivity and EMI shielding performance of the microcellular PI/RGO/MWCNTs nanocomposites. The dominating EMI shielding mechanism for these materials was microwave absorption. While the initial loading of GO and MWCNT was 8 wt%, the microcellular PI/RGO/MWCNTs nanocomposite (500 μm thickness) had extremely high specific EMI SE value of 755-823 dB·cm2·g-1. Its thermal stability was also obviously improved, the 5% weight loss temperature in nitrogen was 548 °C. In addition, it also possessed a high Young's modulus of 789 MPa.

  6. Application of electromagnetic and sound waves in nutritional assessment

    International Nuclear Information System (INIS)

    Heymsfield, S.B.; Rolandelli, R.; Casper, K.; Settle, R.G.; Koruda, M.

    1987-01-01

    Four relatively new techniques that apply electromagnetic or sound waves promise to play a major role in the study of human body composition and in clinical nutritional assessment. Computerized axial tomography, nuclear magnetic resonance, infrared interactance, and ultrasonography provide capabilities for measuring the following: total body and regional fat volume; regional skeletal muscle volume; brain, liver, kidney, heart, spleen, and tumor volume; lean tissue content of triglyceride, iron, and high-energy intermediates; bone density; and cardiac function. Each method is reviewed with regard to basic principles, research and clinical applications, strengths, and limitations.33 references

  7. Age-dependent acute interference with stem and progenitor cell proliferation in the hippocampus after exposure to 1800 MHz electromagnetic radiation.

    Science.gov (United States)

    Xu, Falin; Bai, Qiongdan; Zhou, Kai; Ma, Li; Duan, Jiajia; Zhuang, Fangli; Xie, Cuicui; Li, Wenli; Zou, Peng; Zhu, Changlian

    2017-01-01

    To investigate the effects of exposure to an 1800 MHz electromagnetic field on cell death and cell proliferation in the developing brain, postnatal day 7 (P7) and P21 healthy Kunming mice were randomly assigned into the experimental and control groups. The experimental groups were exposed to an 1800 MHz electromagnetic field for 8 h daily for three consecutive days. The thymidine analog 5-bromo-2-deoxyuridine (BrdU) was injected intraperitoneally 1 h before each exposure session, and all animals were sacrificed 24 h after the last exposure. Cell death and proliferation markers were detected by immunohistochemistry in the dentate gyrus of the hippocampus. Electromagnetic exposure has no influence on cell death in the dentate gyrus of the hippocampus in P7 and P21 mice as indicated by active caspase-3 immunostaining and Fluoro-Jade labeling. The basal cell proliferation in the hippocampus was higher in P7 than in P21 mice as indicated by the number of cells labeled with BrdU and by immunohistochemical staining for phosphor-histone H3 (PHH3) and brain lipid-binding protein (BLBP). Electromagnetic exposure stimulated DNA synthesis in P7 neural stem and progenitor cells, but reduced cell division and the total number of stem cells in the hippocampus as indicated by increased BrdU labeling and reduced PHH3 and BLBP labeling compared to P7 control mice. There were no significant changes in cell proliferation in P21 mice after exposure to the electromagnetic field. These results indicate that interference with stem cell proliferation upon short-term exposure to an 1800 MHz electromagnetic field depends on the developmental stage of the brain.

  8. Animal magnetocardiography using superconducting quantum interference device gradiometers assisted with magnetic nanoparticle injection: A sensitive method for early detecting electromagnetic changes induced by hypercholesterolemia

    Science.gov (United States)

    Wu, C. C.; Hong, B. F.; Wu, B. H.; Yang, S. Y.; Horng, H. E.; Yang, H. C.; Tseng, W. Y. Isaac; Tseng, W. K.; Liu, Y. B.; Lin, L. C.; Lu, L. S.; Lee, Y. H.

    2007-01-01

    In this work, the authors used a superconducting quantum interference device (SQUID) magnetocardiography (MCG) system consisted of 64-channel low-transition-temperature SQUID gradiometers to detect the MCG signals of hepercholesterolemic rabbits. In addition, the MCG signals were recorded before and after the injection of magnetic nanoparticles into the rabbits' ear veins to investigate the effects of magnetic nanoparticles on the MCG signals. These MCG data were compared to those of normal rabbits to reveal the feasibility for early detection of the electromagnetic changes induced by hypercholesterolemia using MCG with the assistance of magnetic nanoparticle injection.

  9. Proactive Interference Slows Recognition by Eliminating Fast Assessments of Familiarity

    Science.gov (United States)

    Oztekin, Ilke; McElree, Brian

    2007-01-01

    The response-signal speed-accuracy tradeoff (SAT) procedure was used to investigate how proactive interference (PI) affects retrieval from working memory. Participants were presented with 6-item study lists, followed immediately by a recognition probe. A variant of a release from PI design was used: All items in a list were from the same semantic…

  10. Shielding effectiveness of a unit of neuro physiology against electromagnetic interference; Eficacia del apantallamiento de una unidad de neurofisiologia frente a interferencias electromagneticas

    Energy Technology Data Exchange (ETDEWEB)

    Febles Santana, V.; Miguel Bilbao, S. de; Lubary Rodriguez, C. S.; Melian del Castillo, M. R.; Herraz Gomez, J. G.; Ramos Gonzalez, V.; Fernandez de Aldecoa, J. C.

    2011-07-01

    During construction of the new building Ambulatory Activity in the Hospital Universitario de Canarias (HUC), was designed and implemented the shield in the form of Faraday cage, five rooms adjacent to the Unit of Neuro physiology, located at the northeast corner 3C plant of the building, in order to sufficiently attenuate radio signals present in the medium and thus enable correct functionality of electro medical equipment free of artifacts caused by external electromagnetic fields. The experience held, once finished the work and commissioning the unit, is that interference is undesirable in some cases even hinder the proper development of medical diagnostic studies. Therefore, technical staff of the Engineering Branch of HUC, initiated a program of measures to determine the effectiveness of the Faraday cage constructed, checking the attenuation levels achieved for frequencies of interest and, if necessary, the deficiencies identified in the design and execution of it, and proposed improvements to minimize interference problems exist.

  11. A strategy to achieve enhanced electromagnetic interference shielding at low concentration with a new generation of conductive carbon black in a chlorinated polyethylene elastomeric matrix.

    Science.gov (United States)

    Mondal, Subhadip; Ganguly, Sayan; Rahaman, Mostafizur; Aldalbahi, Ali; Chaki, Tapan K; Khastgir, Dipak; Das, Narayan Ch

    2016-09-21

    The fabrication of scalable and affordable conductive Ketjen carbon black (K-CB)-elastomer composites for adjustable electromagnetic interference (EMI) shielding remains a difficult challenge. Herein, chlorinated polyethylene (CPE)-K-CB composites have been developed by single step solution mixing to achieve high EMI shielding performance associated with absorption dominance potency by conductive dissipation as well as the reflection of electromagnetic waves. The dispersion of K-CB inside the CPE matrix has been corroborated by electron micrographs and atomic force microscopy (AFM). The K-CB filler and CPE polymer interaction has been investigated through the bound rubber content (Bdr) and the dynamic mechanical properties. The relatively low loading of K-CB with respect to other conventional carbon fillers contributes to a promising low percolation threshold (9.6 wt% K-CB) and a reasonably high EMI shielding effectiveness (EMI SE) value of 38.4 dB (at 30 wt% loading) in the X-band region (8.2 to 12.4 GHz). Classical percolation theory reveals that the electrical conduction behavior through the composite system is quasi-two dimensional in nature. Our belief lies in the promotion of scalable production of flexible and cost-effective K-CB-CPE composites of superior EMI SE to avoid electromagnetic radiation pollution.

  12. AN ANTHOLOGY OF THE DISTINGUISHED ACHIEVEMENTS IN SCIENCE AND TECHNIQUE. PART 33: ELECTROMAGNETIC COMPATIBILITY AND PROTECTION FROM ACTION OF POWERFUL ELECTROMAGNETIC INTERFERENCE OF RADIOELECTRONIC, ELECTRICAL ENGINEERING AND ELECTRIC POWER EQUIPMENT

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2016-09-01

    Full Text Available Purpose. Implementation of brief analytical review of basic scientific and technical achievements in area of electromagnetic compatibility (EMC and protection from destabilizing and striking action of powerful electromagnetic interference (PEMI of natural and artificial origin of radioelectronic, electrical engineering and electric power equipment. Methodology. Scientific methods of collection, analysis and analytical treatment of scientific and technical information in a sphere EMC and such areas of knowledge’s as radioelectronics, electrical engineering and electric power engineering. Results. A brief scientific and technical review is resulted modern positions problems EMC and protection of equipment from action on them PEMI. It is shown that PEMI can result in failures in-process and death of examined equipment. Annual harm in the industrially developed countries of the world from the striking affecting of PEMI modern equipment with integral microcircuits and semiconductor devices can make ten of milliards of USD. The basic methods of protection of equipment are resulted from PEMI and protective devices (PD, intended for the increase of effectiveness of modern equipment to the action of external PEMI. Principles of work of the resulted PD and their basic technical descriptions are described. Originality. On the basis of materials of scientific monographs, journal publications, normative documents and internet-reports systematization of basic PD, in-use presently in an area EMC and protection of different equipment from the hazard agency of external PEMI is executed. Practical value. Popularization of scientific and technical knowledge’s in an area EMC and protection of modern equipment from a dangerous action on them PEMI. Formulation of important for society scientific and technical problems and tasks, arising up in an area EMC and providing of the reliable functioning of modern equipment in power electromagnetic interference.

  13. Assessment of occupational exposure to radio frequency electromagnetic fields

    Directory of Open Access Journals (Sweden)

    Halina Aniołczyk

    2015-06-01

    Full Text Available Background: European Union Directive 2013/35/UE provides for the implementation of EU regulations into national legislation. Our aim is to assess actual health hazards from radiofrequency electromagnetic field (RF EMF (range: 100 kHz – 300 GHz and indicate workplaces with the highest risk to employee health. Material and Methods: Data from measurements of RF EMF performed by the Laboratory of Electromagnetic Hazards in Nofer Institute of Occupational Medicine (Łódź, Poland were analyzed. The analysis covered the results of electric field intensity (E for over 450 selected items. The ranges of protection zones and the extent to which maximum admissible intensity (MAI values were also analyzed. The determinations and measurements of EMF in the work environment met the requirements of Polish Standard, while Polish regulations on the MAI values were used as the criterion for the assessment of the exposure. Results: The highest values of E field intensity at workplaces were measured for: electrosurgery, to 400 V/m, and short-wave diathermy units, to 220 V/m, dielectric welders to 240 V/m, within the FM radio antenna systems, to 180 V/m. The widest protection zones were noted for prototype research instruments, short-wave diathermy units, and dielectric welders. The most excessive (up to 12-fold MAI values were recorded for dielectric welders, short-wave diathermy units (up to 11-fold and microwave diathermy units (up to 8-fold. Conclusions: Our results have confirmed the high RF EMF values for physiotherapists, operators of dielectric welders, and mast maintenance workers in radio communication facilities (especially radio and TV broadcasting stations. Med Pr 2015;66(2:199–212

  14. Semiconductor failure threshold estimation problem in electromagnetic assessment

    International Nuclear Information System (INIS)

    Enlow, E.W.; Wunsch, D.C.

    1984-01-01

    Present semiconductor failure models to predict the one-microsecond square-wave power failure level for use with system electromagnetic (EM) assessments and hardening design are incomplete. This is because for a majority of device types there is insufficient data readily available in a composite data source to quantify the model parameters and the inaccuracy of the models cause complications in definition of adequate hardness margins and quantification of EM performance. This paper presents new semiconductor failure models which use a generic approach that are an integration and simplification of many present models. This generic approach uses two categorical models: one for diodes and transistors, and one for integrated circuits. The models were constructed from a large database of semiconductor failure data. The approach used for constructing diode and transistor failure level models is based on device rated power and are simple to use and universally applicable. The model predicts the value of the 1 μ second failure power to be used in the power failure models P = Kt /SUP -1/2/ or P = K 1 t -1 + K 2 t /SUP -1/2/ + K 3

  15. Preparation and Study of Electromagnetic Interference Shielding Materials Comprised of Ni-Co Coated on Web-Like Biocarbon Nanofibers via Electroless Deposition

    Directory of Open Access Journals (Sweden)

    Xiaohu Huang

    2015-01-01

    Full Text Available Electromagnetic interference (EMI shielding materials made of Ni-Co coated on web-like biocarbon nanofibers were successfully prepared by electroless plating. Biocarbon nanofibers (CF with a novel web-like structure comprised of entangled and interconnected carbon nanoribbons were obtained using bacterial cellulose pyrolyzed at 1200°C. Paraffin wax matrix composites filled with different loadings (10, 20, and 30 wt%, resp. of CF and Ni-Co coated CF (NCCF were prepared. The electrical conductivities and electromagnetic parameters of the composites were investigated by the four-probe method and vector network analysis. From these results, the EMI shielding efficiencies (SE of NCCF composites were shown to be significantly higher than that of CF at the same mass fraction. The paraffin wax composites containing 30 wt% NCCF showed the highest EMI SE of 41.2 dB (99.99% attenuation, which are attributed to the higher electrical conductivity and permittivity of the NCCF composites than the CF composites. Additionally, EMI SE increased with an increase in CF and NCCF loading and the absorption was determined to be the primary factor governing EMI shielding. This study conclusively reveals that NCCF composites have potential applications as EMI shielding materials.

  16. The MONIT project: electromagnetic radiation exposure assessment in mobile communications

    International Nuclear Information System (INIS)

    Carla Oliveira; Daniel Sebastiao; Goncalo Carpinteiro; Luis M Correia; Carlos A Fernandes; Afonso Serralha; Nuno Marques

    2006-01-01

    This paper presents the m.o.n.I.T. Project, a risk communication initiative, providing information to the public on exposure to radiation associated to Electromagnetic Fields (E.M.F.), and performing activities of exposure assessment. M.o.n.I.T. is developed within Instituto de Telecomunicacoes (I.T.) Lisbon site at Instituto Superior Tecnico (I.S.T., Technical University of Lisbon, Portugal), which is a non-profit scientific R and D institute with activities in the Telecommunications area. M.o.n.I.T. started in 2004 in the context of an emergent general public concern about possible health hazards caused by radiation from mobile communication antennas, most of the times rooted in misconceptions about the involved aspects, aggravated by the lack of trusty sources of information capable of presenting it in a simple understandable way. An objective evaluation of the risk requires the quantification of E.M.F. levels to which the population is exposed. Systematic information of this type was not openly available in Portugal, and this was one of the gaps that m.o.n.I.T. filled in, by providing results from extensive measurements campaigns performed in public places over the country for a period that presently mounts to three years. The monitoring system is based on a network of autonomous remote probing stations, and also on an extensive E.M.F. sounding program. Measured results are automatically uploaded to a web site for public dissemination (www.lx.it.pt/monit), which includes also other relevant information about E.M.F. for both the general public and the technical community. This paper describes the project structure and activities in Section 2, the automatic monitoring system in Section 3, and a brief analysis of the measured results in Section 4. Finally, some conclusions are presented in Section 5. (authors)

  17. The MONIT project: electromagnetic radiation exposure assessment in mobile communications

    Energy Technology Data Exchange (ETDEWEB)

    Carla Oliveira; Daniel Sebastiao; Goncalo Carpinteiro; Luis M Correia; Carlos A Fernandes [Instituto de Telecomunicacoes/Instituto Superior Tecnico, Technical University of Lisbon (Portugal); Afonso Serralha; Nuno Marques [Magnete Lisbon (Portugal)

    2006-07-01

    This paper presents the m.o.n.I.T. Project, a risk communication initiative, providing information to the public on exposure to radiation associated to Electromagnetic Fields (E.M.F.), and performing activities of exposure assessment. M.o.n.I.T. is developed within Instituto de Telecomunicacoes (I.T.) Lisbon site at Instituto Superior Tecnico (I.S.T., Technical University of Lisbon, Portugal), which is a non-profit scientific R and D institute with activities in the Telecommunications area. M.o.n.I.T. started in 2004 in the context of an emergent general public concern about possible health hazards caused by radiation from mobile communication antennas, most of the times rooted in misconceptions about the involved aspects, aggravated by the lack of trusty sources of information capable of presenting it in a simple understandable way. An objective evaluation of the risk requires the quantification of E.M.F. levels to which the population is exposed. Systematic information of this type was not openly available in Portugal, and this was one of the gaps that m.o.n.I.T. filled in, by providing results from extensive measurements campaigns performed in public places over the country for a period that presently mounts to three years. The monitoring system is based on a network of autonomous remote probing stations, and also on an extensive E.M.F. sounding program. Measured results are automatically uploaded to a web site for public dissemination (www.lx.it.pt/monit), which includes also other relevant information about E.M.F. for both the general public and the technical community. This paper describes the project structure and activities in Section 2, the automatic monitoring system in Section 3, and a brief analysis of the measured results in Section 4. Finally, some conclusions are presented in Section 5. (authors)

  18. Electromagnetic compatibility of nuclear power plants

    International Nuclear Information System (INIS)

    Cabayan, H.S.

    1983-01-01

    Lately, there has been a mounting concern about the electromagnetic compatibility of nuclear-power-plant systems mainly because of the effects due to the nuclear electromagnetic pulse, and also because of the introduction of more-sophisticated and, therefore, more-susceptible solid-state devices into the plants. Questions have been raised about the adequacy of solid-state-device protection against plant electromagnetic-interference sources and transients due to the nuclear electromagnetic pulse. In this paper, the author briefly reviews the environment, and the coupling, susceptibility, and vulnerability assessment issues of commercial nuclear power plants

  19. Electromagnetic configurable architectures for assessment of Carbon Fiber Reinforced Plastics

    Directory of Open Access Journals (Sweden)

    Steigmann Rozina

    2017-01-01

    Full Text Available Carbon Fiber Reinforced Plastics are used in most wide domains due their low density, lack of mechanical fatigue phenomena and high strength–to weight ratio. From electromagnetic point of view, Carbon Fiber Reinforced Plastics structure represents an inhomogeneous structure of electric conductive fibers embedded into a dielectric material, thus an electromagnetic configurable architecture can be used to evaluate above mentioned defects. The paper proposes a special sensor, send receiver type and the obtaining of electromagnetic image by post-processing each coil signals in each point of scanning, using a sub-encoding image reconstruction algorithm and super-resolution procedures. The layout of fibers can be detected interrogating only diagonal reception coils.

  20. Detection and elimination of the electromagnetic interferences in the neutron flux measurement circuit, Source Range; Deteccion y eliminacion de interferencias electromagneticas en el circuito de medicion de flujo neutronico, rango de fuente

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, J. M.; Esguivillas, L.; Valle, J. L.

    2010-07-01

    This paper compiles an experience in Asco I Nuclear Power Plant about electromagnetic interferences associated to the neutron flux measurement system, Source Range Asco I NPP. The circuit affected is the proportional detector (BF3) located outside the reactor vessel to measure the neutron leakage in shutdown and in start-up.

  1. Assessment of distraction from erotic stimuli by nonerotic interference.

    Science.gov (United States)

    Anderson, Alex B; Hamilton, Lisa Dawn

    2015-01-01

    Distraction from erotic cues during sexual encounters is a major contributor to sexual difficulties in men and women. Being able to assess distraction in studies of sexual arousal will help clarify underlying contributions to sexual problems. The current study aimed to identify the most accurate assessment of distraction from erotic cues in healthy men (n = 29) and women (n = 38). Participants were assigned to a no distraction, low distraction, or high distraction condition. Distraction was induced using an auditory distraction task presented during the viewing of an erotic video. Attention to erotic cues was assessed using three methods: a written quiz, a visual quiz, and a self-reported distraction measure. Genital and psychological sexual responses were also measured. Self-reported distraction and written quiz scores most accurately represented the level of distraction present, while self-reported distraction also corresponded with a decrease in genital arousal. Findings support the usefulness of self-report measures in conjunction with a brief quiz on the erotic material as the most accurate and sensitive ways to simply measure experimentally-induced distraction. Insight into distraction assessment techniques will enable evaluation of naturally occurring distraction in patients suffering from sexual problems.

  2. Electromagnetic Radiation: Final Range Environmental Assessment, Revision 1

    Science.gov (United States)

    2009-12-03

    typically include residential, commercial, industrial , agricultural, military, and recreational. Land use also includes areas set aside for...procedures, controls, shielding standards, nominal ocular hazard distance, protective eyewear verification, radiation footprint determination, and...from human activities. An example of these activities includes using the electromagnetic (EM) energy spectrum for communications and industrial

  3. [Interference of vitamin E on the brain tissue damage by electromagnetic radiation of cell phone in pregnant and fetal rats].

    Science.gov (United States)

    Gao, Xian; Luo, Rui; Ma, Bin; Wang, Hui; Liu, Tian; Zhang, Jing; Lian, Zhishun; Cui, Xi

    2013-07-01

    To investigate the interlerence ot vitamin E on brain tissue damage by electromagnetic radiation of cell phone in pregnant and fetal rats. 40 pregnant rats were randomly divided into five groups (positive control, negative control, low, middle and high dosage of vitamin E groups). The low, middle and high dosage of vitamin E groups were supplemented with 5, 15 and 30 mg/ml vitamin E respectively since the first day of pregnancy. And the negative control group and the positive control group were given peanut oil without vitamin E. All groups except for the negative control group were exposed to 900MHz intensity of cell phone radiation for one hour each time, three times per day for 21 days. After accouchement, the right hippocampus tissue of fetal rats in each group was taken and observed under electron microscope. The vitality of superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px), and the content of malondialdehyde (MDA) in pregnant and fetal rats' brain tissue were tested. Compared with the negative control group, the chondriosomes in neuron and neuroglia of brain tissues was swelling, mild edema was found around the capillary, chromatin was concentrated and collected, and bubbles were formed in vascular endothelial cells (VEC) in the positive fetal rat control group, whereas the above phenomenon was un-conspicuous in the middle and high dosage of vitamin E groups. We can see uniform chromatin, abundant mitochondrion, rough endoplasmic reticulum and free ribosomes in the high dosage group. The apoptosis has not fond in all groups'sections. In the antioxidase activity analysis, compared with the negative control group, the vitality of SOD and GSH-Px significantly decreased and the content of MDA significantly increased both in the pregnant and fetal rats positive control group (P electromagnetic radiation of cell phone in pregnant rats and fetal rats.

  4. Synthesis of MoS2-reduced graphene oxide/Fe3O4 nanocomposite for enhanced electromagnetic interference shielding effectiveness

    Science.gov (United States)

    Prasad, Jagdees; Singh, Ashwani Kumar; Shah, Jyoti; Kotnala, R. K.; Singh, Kedar

    2018-05-01

    This article presents a facile two step hydrothermal process for the synthesis of MoS2-reduced graphene oxide/Fe3O4 (MoS2-rGO/Fe3O4) nanocomposite and its application as an excellent electromagnetic interference shielding material. Characterization tools like; scanning electron microscope, transmission electron microscope, x-ray diffraction, and Raman spectroscopy were used to confirm the formation of nanocomposite and found that spherical Fe3O4 nanoparticles are well dispersed over MoS2-rGO composite with average particle size ∼25–30 nm was confirmed by TEM. Structural characterization done by XRD was found inconsistent with the known lattice parameter of MoS2 nanosheet, reduced graphene oxide and Fe3O4 nanoparticles. Electromagnetic shielding effectiveness of MoS2-rGO/Fe3O4 nanocomposite was evaluated and found to be an excellent EMI shielding material in X-band range (8.0–12.0 GHz). MoS2-rGO composite shows poor shielding capacity (SET ∼ 3.81 dB) in entire range as compared to MoS2-rGO/Fe3O4 nanocomposite (SET ∼ 8.27 dB). It is due to interfacial polarization in the presence of EM field. The result indicates that MoS2-rGO/Fe3O4 nanocomposite provide a new stage for the next generation in high-performance EM wave absorption and EMI shielding effectiveness.

  5. Fabrication of conducting composite sheets using cost-effective graphite flakes and amorphous styrene acrylonitrile for enhanced thermistor, dielectric, and electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Panwar, Varij, E-mail: varijpanwarcertain@gmail.com [Electronics and Communication Engineering, Graphic Era University, Dehradun, Uttarakhand (India); Gill, Fateh Singh; Rathi, Vikas; Tewari, V.K. [Electronics and Communication Engineering, Graphic Era University, Dehradun, Uttarakhand (India); Mehra, R.M. [Sharda University, Greater Noida (India); Park, Jong-Oh, E-mail: jop@jnu.ac.kr [School of Mechanical Engineering, Chonnam National University, Gwangju (Korea, Republic of); Park, Sukho, E-mail: shpark12@dgist.ac.kr [Department of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology, Daegu (Korea, Republic of)

    2017-06-01

    The fabrication of strong conducting composite sheets (CCSs) using a simple technique with cost-effective materials is desirable for capacitor, decoupling capacitor, and electromagnetic interference (EMI) shielding applications. Here, we used cost-effective graphite flakes (GFs) as a conducting filler and amorphous poly (styrene-co-acrylonitrile) (PSAN) as an insulating polymer to fabricate a CCS via a simple mechanical mixing and hot compression molding process in 2.5 h, with the aim to save time and avoid the use of toxic reagents, which are generally used in chemical methods. In the present method, the GFs are connected in diffusively adhere polymer matrix, controlled by temperature and pressure that generate the conduction in the CCSs. The resulting PSAN/GF CCSs were characterized by using scanning electron microscopy (SEM), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and hardness tests. The GFs penetrated the interfacial region of PSAN, thus improving the thermistor and dielectric properties (dielectric constant, AC conductivity, and dissipation factor) of the PSAN/GF CCSs. Furthermore, the PSAN/GF CCSs showed enhanced hardness and EMI shielding effectiveness (SE) properties in the X-band frequency range (8.5–12.5 GHz). The percolation theory was implemented to DC and AC conductivity. To detect the transition of the dielectric properties, the dielectric constant of the CCSs was analyzed with increasing volume fraction of GFs in the radio frequency region. The improved dielectric constant, AC conductivity, and dissipation factor of the PSAN/GF CCS, indicated a significant improvement in their EMI shielding properties in the X-band frequency range, which were measured using the waveguide method. The ac conductivity of PSAN/GF CCS shows stable behavior in the higher frequency ranges. The EMISE of PSAN/GF CCS were found to increase with increasing GF content due to the absorbance mechanism. - Highlights: • Enhanced hardness and

  6. Mechanically Robust Magnetic Carbon Nanotube Papers Prepared with CoFe2O4 Nanoparticles for Electromagnetic Interference Shielding and Magnetomechanical Actuation.

    Science.gov (United States)

    Lim, Guh-Hwan; Woo, Seongwon; Lee, Hoyoung; Moon, Kyoung-Seok; Sohn, Hiesang; Lee, Sang-Eui; Lim, Byungkwon

    2017-11-22

    The introduction of inorganic nanoparticles into carbon nanotube (CNT) papers can provide a versatile route to the fabrication of CNT papers with diverse functionalities, but it may lead to a reduction in their mechanical properties. Here, we describe a simple and effective strategy for the fabrication of mechanically robust magnetic CNT papers for electromagnetic interference (EMI) shielding and magnetomechanical actuation applications. The magnetic CNT papers were produced by vacuum filtration of an aqueous suspension of CNTs, CoFe 2 O 4 nanoparticles, and poly(vinyl alcohol) (PVA). PVA plays a critical role in enhancing the mechanical strength of CNT papers. The magnetic CNT papers containing 73 wt % of CoFe 2 O 4 nanoparticles exhibited high mechanical properties with Young's modulus of 3.2 GPa and tensile strength of 30.0 MPa. This magnetic CNT paper was successfully demonstrated as EMI shielding paper with shielding effectiveness of ∼30 dB (99.9%) in 0.5-1.0 GHz, and also as a magnetomechanical actuator in an audible frequency range from 200 to 20 000 Hz.

  7. AC conductivity, magnetic and shielding effectiveness studies on polyaniline embedded Co0.5Mn0.5Fe2O4 nanoparticles for electromagnetic interference suppression

    Science.gov (United States)

    Gurusiddesh, M.; Madhu, B. J.; Shankaramurthy, G. J.

    2018-05-01

    Electrically conducting Polyaniline (PANI)/Co0.5Mn0.5Fe2O4 nanocomposites are synthesized by in situ polymerization of aniline monomer in the presence of Co0.5Mn0.5Fe2O4 nanoparticles. Structural studies on the synthesized samples have been carried out using X-ray diffraction technique, Field emission scanning electron microscopy and Energy dispersive X-ray spectroscopy. Frequency dependent ac conductivity studies on the prepared samples revealed that conductivity of the composite is high compared to Co0.5Mn0.5Fe2O4 nanoparticles. Further, both the samples exhibited hysteresis behavior under the applied magnetic field. Electromagnetic interference (EMI) shielding effectiveness of both the samples decreases with increase in the applied frequency in the studied frequency range. Maximum shielding effectiveness (SE) of 31.49 dB and 62.84 dB were obtained for Co0.5Mn0.5Fe2O4 nanoparticles and PANI/Co0.5Mn0.5Fe2O4 nanocomposites respectively in the studied frequency range. Observed higher EMI shielding in the composites was attributed to its high electrical conductivity.

  8. Comprehensive vulnerability assessment method for nodes considering anti-interference ability and influence

    Science.gov (United States)

    LUO, Jianchun; WANG, Yunyu; YANG, Jun; RAN, hong; PENG, Xiaodong; HUANG, Ming; FENG, Hao; LIU, Meijun

    2018-03-01

    The vulnerability assessment of power grid is of great significance in the current research. Power system faces many kinds of uncertainty factors, and the disturbance caused by them has become one of the main factors which restrict the safe operation of power grid. To solve this problem, considering the anti-interference ability of the system when the system is disturbed and the effect of the system when the node is out of operation, a set of index to reflect the anti-interference ability and the influence of nodes are set up. On this basis, a new comprehensive vulnerability assessment method of nodes is put forward by using super efficiency data envelopment analysis to scientific integration. Finally, the simulative results of IEEE30-bus system indicated that the proposed model is rational and valid.

  9. Structural, magnetic and microwave absorption behavior of Co-Zr substituted strontium hexaferrites prepared using tartaric acid fuel for electromagnetic interference suppression

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Prabhjyot, E-mail: prabhjyot.2525@gmail.com [Department of Chemistry, Centre for Advanced Studies-I, Guru Nanak Dev University, Amritsar 143005 (India); Chawla, S.K., E-mail: sschawla118@gmail.com [Department of Chemistry, Centre for Advanced Studies-I, Guru Nanak Dev University, Amritsar 143005 (India); Narang, Sukhleen Bindra, E-mail: sukhleen2@yahoo.com [Department of Electronics Technology, Guru Nanak Dev University, Amritsar 143005 (India); Pubby, Kunal, E-mail: kunalpubby02@gmail.com [Department of Electronics Technology, Guru Nanak Dev University, Amritsar 143005 (India)

    2017-01-15

    Strontium hexaferrites, doped with varying Co-Zr content (x) have been synthesized by sol-gel auto-combustion route using tartaric acid as fuel at 800 °C. X-ray diffraction and Fourier transform Infra-red have been carried out to confirm the phase formation, particle size (average 21.9–36.8 nm) and the bond formation respectively. Magnetic properties are scrutinized using vibrating sample magnetometer. Techniques like scanning electron microscopy, transmission electron microscopy and energy dispersive scattering have been employed to explore the surface morphology, particle size and composition of the nano-powders. Electromagnetic characterization of the prepared ferrites has been done using Vector Network Anlyzer in 12.4–18 GHz frequency range. The effect of calcination temperature (500–1000 °C) on the structure, morphology and magnetic properties has also been studied for x=0.2 and 800 °C has been found to be the most suitable temperature with the best magnetic properties. Increase in doping has resulted in resonance peaks in dielectric and magnetic loss spectra, leading to microwave absorption peaks. Ferrites with x=0.2, 0.8 and 1.0 have appropriate reflection loss less than −10 dB and bandwidth in Ku-band, hence can be used as effective absorbers in suppression of electromagnetic interference (EMI). The governance of impedance matching in deciding the absorption properties has been proved by using input impedance calculations. - Highlights: • Co-Zr doped strontium hexaferrite nanopowders have been prepared by sol-gel route. • 800 °C was most suitable temperaturewith best structural and magnetic properties. • Samples have M-type hexagonal structure with an average particle size of 36.47 nm. • Samples x=0.2, 0.8 and 1.0 are suitable for suppression of EM waves in Ku-band. • The origin of absorption peaks: impedance matching and losses has been explained.

  10. Electromagnetic topology: Characterization of internal electromagnetic coupling

    Science.gov (United States)

    Parmantier, J. P.; Aparicio, J. P.; Faure, F.

    1991-01-01

    The main principles are presented of a method dealing with the resolution of electromagnetic internal problems: Electromagnetic Topology. A very interesting way is to generalize the multiconductor transmission line network theory to the basic equation of the Electromagnetic Topology: the BLT equation. This generalization is illustrated by the treatment of an aperture as a four port junction. Analytical and experimental derivations of the scattering parameters are presented. These concepts are used to study the electromagnetic coupling in a scale model of an aircraft, and can be seen as a convenient means to test internal electromagnetic interference.

  11. Ecological momentary assessment of the relationship between headache pain intensity and pain interference in women with migraine and obesity.

    Science.gov (United States)

    Thomas, J Graham; Pavlovic, Jelena; Lipton, Richard B; Roth, Julie; Rathier, Lucille; O'Leary, Kevin C; Buse, Dawn C; Evans, E Whitney; Bond, Dale S

    2016-11-01

    Background While pain intensity during migraine headache attacks is known to be a determinant of interference with daily activities, no study has evaluated: (a) the pain intensity-interference association in real-time on a per-headache basis, (b) multiple interference domains, and (c) factors that modify the association. Methods Participants were 116 women with overweight/obesity and migraine seeking behavioral treatment to lose weight and decrease headaches in the Women's Health and Migraine trial. Ecological momentary assessment, via smartphone-based 28-day headache diary, and linear mixed-effects models were used to study associations between pain intensity and total- and domain-specific interference scores using the Brief Pain Inventory. Multiple factors (e.g. pain catastrophizing (PC) and headache management self-efficacy (HMSE)) were evaluated either as independent predictors or moderators of the pain intensity-interference relationship. Results Pain intensity predicted degree of pain interference across all domains either as a main effect (coeff = 0.61-0.78, p < 0.001) or interaction with PC, allodynia, and HMSE ( p < 0.05). Older age and greater allodynia consistently predicted higher interference, regardless of pain intensity (coeff = 0.04-0.19, p < 0.05). Conclusions Pain intensity is a consistent predictor of pain interference on migraine headache days. Allodynia, PC, and HMSE moderated the pain intensity-interference relationship, and may be promising targets for interventions to reduce pain interference.

  12. Lightweight reduced graphene oxide-Fe3O4 nanoparticle composite in the quest for an excellent electromagnetic interference shielding material

    Science.gov (United States)

    Singh, Ashwani Kumar; Kumar, Ajit; Kamal Haldar, Krishna; Gupta, Vinay; Singh, Kedar

    2018-06-01

    This work reports a detailed study of reduced graphene oxide (rGO)-Fe3O4 nanoparticle composite as an excellent electromagnetic (EM) interference shielding material in GHz range. A rGO-Fe3O4 nanoparticle composite was synthesized using a facile, one step, and modified solvothermal method with the reaction of FeCl3, ethylenediamine and graphite oxide powder in the presence of ethylene glycol. Various structural, microstructural and optical characterization tools were used to determine its synthesis and various properties. Dielectric, magnetic and EM shielding parameters were also evaluated to estimate its performance as a shielding material for EM waves. X-ray diffraction patterns have provided information about the structural and crystallographic properties of the as-synthesized material. Scanning electron microscopy micrographs revealed the information regarding the exfoliation of graphite into rGO. Well-dispersed Fe3O4 nanoparticles over the surface of the graphene can easily be seen by employing transmission electron microscopy. For comparison, rGO nanosheets and Fe3O4 nanoparticles have also been synthesized and characterized in a similar fashion. A plot of the dielectric and magnetic characterizations provides some useful information related to various losses and the relaxation process. Shielding effectiveness due to reflection (SER), shielding effectiveness due to absorption (SEA), and total shielding effectiveness (SET) were also plotted against frequency over a broad range (8–12 GHz). A significant change in all parameters (SEA value from 5 dB to 35 dB for Fe3O4 nanoparticles to rGO-Fe3O4 nanoparticle composite) was found. An actual shielding effectiveness (SET) up to 55 dB was found in the rGO-Fe3O4 nanoparticle composite. These graphs give glimpses of how significantly this material shows shielding effectiveness over a broad range of frequency.

  13. Lightweight reduced graphene oxide-Fe3O4 nanoparticle composite in the quest for an excellent electromagnetic interference shielding material.

    Science.gov (United States)

    Singh, Ashwani Kumar; Kumar, Ajit; Haldar, Krishna Kamal; Gupta, Vinay; Singh, Kedar

    2018-06-15

    This work reports a detailed study of reduced graphene oxide (rGO)-Fe 3 O 4 nanoparticle composite as an excellent electromagnetic (EM) interference shielding material in GHz range. A rGO-Fe 3 O 4 nanoparticle composite was synthesized using a facile, one step, and modified solvothermal method with the reaction of FeCl 3 , ethylenediamine and graphite oxide powder in the presence of ethylene glycol. Various structural, microstructural and optical characterization tools were used to determine its synthesis and various properties. Dielectric, magnetic and EM shielding parameters were also evaluated to estimate its performance as a shielding material for EM waves. X-ray diffraction patterns have provided information about the structural and crystallographic properties of the as-synthesized material. Scanning electron microscopy micrographs revealed the information regarding the exfoliation of graphite into rGO. Well-dispersed Fe 3 O 4 nanoparticles over the surface of the graphene can easily be seen by employing transmission electron microscopy. For comparison, rGO nanosheets and Fe 3 O 4 nanoparticles have also been synthesized and characterized in a similar fashion. A plot of the dielectric and magnetic characterizations provides some useful information related to various losses and the relaxation process. Shielding effectiveness due to reflection (SE R ), shielding effectiveness due to absorption (SE A ), and total shielding effectiveness (SE T ) were also plotted against frequency over a broad range (8-12 GHz). A significant change in all parameters (SE A value from 5 dB to 35 dB for Fe 3 O 4 nanoparticles to rGO-Fe 3 O 4 nanoparticle composite) was found. An actual shielding effectiveness (SE T ) up to 55 dB was found in the rGO-Fe 3 O 4 nanoparticle composite. These graphs give glimpses of how significantly this material shows shielding effectiveness over a broad range of frequency.

  14. Comparative study of electroless Co-Ni-P plating on Tencel fabric by Co0-based and Ni0-based activation for electromagnetic interference shielding

    Science.gov (United States)

    Bi, Siyi; Zhao, Hang; Hou, Lei; Lu, Yinxiang

    2017-10-01

    The primary objective of this research work was to develop high-performance conductive fabrics with desired electromagnetic interference (EMI) shielding effectiveness (SE), excellent durability and improved corrosion resistance. Such conductive fabrics were fabricated by combining an ultra-low-cost electroless plating method with an alkoxy silane self-assembly technology, which involved successive steps of modification, activation, Co-Ni-P coating deposition and 3-aminopropyltrimethoxysilane (APTMS) thin coatings assembling. Malic acid (MA) was selected to modify the pristine Tencel (TS) substrates, and the probably interaction mechanism was investigated by FT-IR measurement. Co0 and Ni0 nanoparticles (NPs) were used as the activators to initiate electroless plating, respectively, and thereby two categories of Co-Ni-P coatings with different Co/Ni atomic ratio were obtained. Both of them presented compact morphologies and preferential (1 1 1) crystal orientation, which were validated by FE-SEM and XRD measurements. Owing to the lower square resistance and higher magnetic properties, the Co-Ni-P coated fabric activated by Co0 activator showed a higher EMI SE (18.2-40.1 dB) at frequency of 30-1000 MHz. APTMS thin coatings were then assembled on the top of alloy coated fabrics to act as anti-corrosion barriers. Electrochemical polarization measurement in 3.5 wt.% NaCl solution showed that top-APTMS coated conductive fabric exhibited a higher corrosion resistance than the one in absence of APTMS assembly. Overall, the whole process of fabrication could be performed in several hours (or less) without any specialized equipment, which shows a great potential as EMI shielding fabrics in mass-production.

  15. Electromagnetic Noise Interference and Compatibility

    Science.gov (United States)

    1975-11-01

    L ’on trouve dane 74 haute atmoephire rdeister aux grande froide ainei qu ’l La granda ohaZemn, rsie ter d La dipreesion, aux paesa~go dane L ’lau...ent rhacteura code no 071482 du 26/8/69 eat absolument identique A Is sp6cification DOUGLAS. En ce qui concerne lea essaia aux transitoires de courte

  16. Assessment of proposed electromagnetic quantum vacuum energy extraction methods

    OpenAIRE

    Moddel, Garret

    2009-01-01

    In research articles and patents several methods have been proposed for the extraction of zero-point energy from the vacuum. None has been reliably demonstrated, but the proposals remain largely unchallenged. In this paper the feasibility of these methods is assessed in terms of underlying thermodynamics principles of equilibrium, detailed balance, and conservation laws. The methods are separated into three classes: nonlinear processing of the zero-point field, mechanical extraction using Cas...

  17. Electromagnetic shielding

    International Nuclear Information System (INIS)

    Tzeng, Wen-Shian V.

    1991-01-01

    Electromagnetic interference (EMI) shielding materials are well known in the art in forms such as gaskets, caulking compounds, adhesives, coatings and the like for a variety of EMI shielding purposes. In the past, where high shielding performance is necessary, EMI shielding has tended to use silver particles or silver coated copper particles dispersed in a resin binder. More recently, aluminum core silver coated particles have been used to reduce costs while maintaining good electrical and physical properties. (author). 8 figs

  18. Electromagnetic fields: risk assessment and occupational diseases in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Filosa, L.; Frusteri, L. [Risk Assessment and Prevention, Technical Advisory Dept., Italian Workers Compensation Authority, Rome (Italy)

    2006-07-01

    Every year about 8000 occupational diseases are accepted in Italy by I.N.A.I.L., the Italian Workers' Compensation Authority. The occupational diseases are caused by different agents (chemical, biological, physical) but only a very little percentage resulted to be caused by non ionizing radiations. In this paper the Authors report an analysis of occupational diseases caused by non ionising radiations denounced to I.N.A.I.L. and compensated. It is discussed the Italian situation in light of the controversial studies related to the link between exposure and health effects. Because of the uncertainty about an E.M.F. - health link, the main effort is to determine the probability and seriousness of E.M.F. hazard and to realize an accurate risk assessment at workplace, which is one of the main objectives pursued by I.N.A.I.L. Technical Advisory Department for Risk Assessment and Prevention. Moreover, in this paper it is also reported the state of advancement of Italian legislation on health protection against non ionizing radiations at workplace in view of the new European Directive (2004/40/C.E.). (authors)

  19. Electromagnetic fields: risk assessment and occupational diseases in Italy

    International Nuclear Information System (INIS)

    Filosa, L.; Frusteri, L.

    2006-01-01

    Every year about 8000 occupational diseases are accepted in Italy by I.N.A.I.L., the Italian Workers' Compensation Authority. The occupational diseases are caused by different agents (chemical, biological, physical) but only a very little percentage resulted to be caused by non ionizing radiations. In this paper the Authors report an analysis of occupational diseases caused by non ionising radiations denounced to I.N.A.I.L. and compensated. It is discussed the Italian situation in light of the controversial studies related to the link between exposure and health effects. Because of the uncertainty about an E.M.F. - health link, the main effort is to determine the probability and seriousness of E.M.F. hazard and to realize an accurate risk assessment at workplace, which is one of the main objectives pursued by I.N.A.I.L. Technical Advisory Department for Risk Assessment and Prevention. Moreover, in this paper it is also reported the state of advancement of Italian legislation on health protection against non ionizing radiations at workplace in view of the new European Directive (2004/40/C.E.). (authors)

  20. Assessment of colorectal length using the electromagnetic capsule tracking system

    DEFF Research Database (Denmark)

    Mark, E B; Poulsen, J L; Haase, A M

    2017-01-01

    AIM: We aimed to determine colorectal length with the 3D-Transit system by describing a 'centerline' of capsule movement and compare it to known anatomy, as determined by magnetic resonance imaging (MRI). Further, we aimed to test the day-to-day variation of colorectal length assessed......: Computation of colorectal length from capsule passage was possible in 60 of the 67 3D-Transit recordings. Length of the colorectum measured with MRI and 3D-Transit was respectively 95 cm (75-153 cm) and 99 cm (77-147 cm), P = 0.15. Coefficient of variation (CV) between MRI and 3D-Transit was 7.8%. Apart from...... the cecum / ascending colon being 26% (P = 0.002) shorter on MRI, there were no other differences in total or segmental colorectal lengths between methods (all P > 0.05). Length of the colorectum measured with 3D-Transit on two consecutive days was 102 cm (73-119 cm) and 103 cm (75-123 cm), P = 0.67. CV...

  1. Integrating electromagnetic radiation hazard info the unique occupational risk assessment document

    International Nuclear Information System (INIS)

    Demaret, P.; Donati, P.

    2011-01-01

    The number of industrial applications involving electromagnetic waves has significantly increased in recent years. These applications are likely to expose operators to electromagnetic fields exceeding the limits laid down by European Parliament and Council Directive 2004/40/CE of 29 April 2004. A survey has identified the equipment emitting the most radiation and this has been classified into 8 families: resistance welding, magnetization, induction heating, magneto-scopy, dielectric loss welding, electrolysis, magnetic resonance imagery, microwaves. The equipment numbers per family was estimated by a market surveys, which specifically identified several tens of thousands of resistance welding- or magnetization-type machines. This survey enabled us to deduce that at least 100,000 operators in France would be at risk of exposure to electromagnetic fields. An assessment of exposure levels for operators at their workstations was undertaken for each equipment family. A group comprising specialists from INRS and the 9 CARSAT/CRAM Physical Measurement Centres measured electromagnetic fields at 635 workstations fitted with radiation emitting machinery. For each measurement, a severity index corresponding to the ratio of the measured value to the action-triggering value (ATV) recommended by European Parliament and Council Directive 2004/40/CE of 29 April 2004 was calculated. The results show that, for 7 equipment families out of the 8 retained, 25 - 50% of measurements gave electromagnetic field values exceeding the corresponding ATV. These results demonstrate the need for prevention means. In most cases, exposure reduction is achieved by moving the workstation away from the radiation source. Technical solutions do exist for certain equipments, such as shielding for microwave ovens and high-frequency presses, a grounding pad for tarpaulin welding, etc. (authors)

  2. Assessment of anhedonia in psychological trauma: development of the Hedonic Deficit and Interference Scale

    Directory of Open Access Journals (Sweden)

    Paul A. Frewen

    2012-01-01

    Full Text Available Symptoms of anhedonia, or deficits in the ability to experience positive affect, are increasingly recognized as an outcome of traumatic stress. Herein we demonstrate a phenomenon of “negative affective interference”, specifically, negative affective responses to positive events, in association with childhood trauma history. Young adults (n=99 completed a Hedonic Deficit & Interference Scale (HDIS, a self-report measure developed for this study, as well as a modified version of the Fawcette-Clarke Pleasure Capacity Scale that assessed not only positive but also negative affective responses to positive events. The two assessment approaches demonstrated convergent validity and predicted concurrent individual differences in trait positive and negative affect, and extraversion and neuroticism. Histories of childhood emotional and sexual abuse were differentially associated with negative affective responses to positive events. Future research and clinical directions are discussed.For the abstract or full text in other languages, please see Supplementary files under Reading Tools online.

  3. Report of the Commission to Assess the Threat to the United States from Electromagnetic Pulse (EMP) Attack: Critical National Infrastructures

    National Research Council Canada - National Science Library

    Foster, Jr., John S; Gjelde, Earl; Graham, William R; Hermann, Robert J; Kluepfel, Henry M; Lawson, Richard L; Soper, Gordon K; Wood, Lowell L; Woodard, Joan B

    2008-01-01

    ...) attack on our critical national infrastructures. An earlier report, Report of the Commission to Assess the Threat to the United States from Electromagnetic Pulse (EMP), Volume 1: Executive Report (2004...

  4. A survey to assess the educational-level interference on self-evaluation of acute pain.

    Science.gov (United States)

    Labronici, Pedro José; Pires, Robinson Esteves Santos; Bastos Filho, Ricardo Pinheiro dos Santos; Pires-e-Albuquerque, Rodrigo Sattamini; Palma, Idemar Monteiro de; Giordano, Vincenzo; Franco, José Sérgio

    2015-08-01

    The present study aimed to evaluate whether patient education level interferes in the percentage of pain relief or increase using visual analogue scale (VAS) and subjective pain perception. Ninety-five patients presenting acute shoulder pain due to enthesitis were evaluated. They were asked to quantify the pain using VAS before steroid articular infiltration. One week later, patients reevaluated the pain using VAS and orally stated the percentage of perceived pain increase or relief. The information gathered was then compared among three patient educational levels (elementary, high school, and university). Percentages of improvement stated orally and utilizing VAS presented no statistically significant differences among the three educational status levels (p = 0.804). Patient educational status caused no impact in the results of acute pain self-assessment with VAS and oral evaluation.

  5. The assessment of electromagnetic field radiation exposure for mobile phone users

    Directory of Open Access Journals (Sweden)

    Buckus Raimondas

    2014-01-01

    Full Text Available Background/Aim. During recent years, the widespread use of mobile phones has resulted in increased human exposure to electromagnetic field radiation and to health risks. Increased usage of mobile phones at the close proximity raises questions and doubts in safety of mobile phone users. The aim of the study was to assess an electromagnetic field radiation exposure for mobile phone users by measuring electromagnetic field strength in different settings at the distance of 1 to 30 cm from the mobile user. Methods. In this paper, the measurements of electric field strength exposure were conducted on different brand of mobile phones by the call-related factors: urban/rural area, indoor/outdoor setting and moving/stationary mode during calls. The different types of mobile phone were placed facing the field probe at 1 cm, 10 cm, 20 cm and 30 cm distance. Results. The highest electric field strength was recorded for calls made in rural area (indoors while the lowest electric field strength was recorded for calls made in urban area (outdoors. Calls made from a phone in a moving car gave a similar result like for indoor calls; however, calls made from a phone in a moving car exposed electric field strength two times more than that of calls in a standing (motionless position. Conclusion. Electromagnetic field radiation depends on mobile phone power class and factors, like urban or rural area, outdoor or indoor, moving or motionless position, and the distance of the mobile phone from the phone user. It is recommended to keep a mobile phone in the safe distance of 10, 20 or 30 cm from the body (especially head during the calls.

  6. Large wind turbine siting handbook: television interference assessment. Final subcontract report

    Energy Technology Data Exchange (ETDEWEB)

    Senior, T B.A.; Sengupta, D L

    1983-01-01

    The rotating blades of a horizontal axis wind turbine can distort the video portion of a television signal and thereby interfere with TV reception in the vicinity of the machine. The nature of this interference is described and methods are presented for calculating the zone within which the interference may be severs. Specific results are given for the MOD-OA, MOD-1 and MOD-2 machines as functions of the TV frequency.

  7. Transient Electromagnetic Modelling and Imaging of Thin Resistive Structures: Applications for Gas Hydrate Assessment

    Science.gov (United States)

    Swidinsky, Andrei

    Gas hydrates are a solid, ice-like mixture of water and low molecular weight hydrocarbons. They are found under the permafrost and to a far greater extent under the ocean, usually at water depths greater than 300m. Hydrates are a potential energy resource, a possible factor in climate change, and a geohazard. For these reasons, it is critical that gas hydrate deposits are quantitatively assessed so that their concentrations, locations and distributions may be established. Due to their ice-like nature, hydrates are electrically insulating. Consequently, a method which remotely detects changes in seafloor electrical conductivity, such as marine controlled source electromagnetics (CSEM), is a useful geophysical tool for marine gas hydrate exploration. Hydrates are geometrically complex structures. Advanced electromagnetic modelling and imaging techniques are crucial for proper survey design and data interpretation. I develop a method to model thin resistive structures in conductive host media which may be useful in building approximate geological models of gas hydrate deposits using arrangements of multiple, bent sheets. I also investigate the possibility of interpreting diffusive electromagnetic data using seismic imaging techniques. To be processed in this way, such data must first be transformed into its non-diffusive, seismic-like counterpart. I examine such a transform from both an analytical and a numerical point of view, focusing on methods to overcome inherent numerical instabilities. This is the first step to applying seismic processing techniques to CSEM data to rapidly and efficiently image resistive gas hydrate structures. The University of Toronto marine electromagnetics group has deployed a permanent marine CSEM array offshore Vancouver Island, in the framework of the NEPTUNE Canada cabled observatory, for the purposes of monitoring gas hydrate deposits. In this thesis I also propose and examine a new CSEM survey technique for gas hydrate which would

  8. Radio frequency electromagnetic field compliance assessment of multi-band and MIMO equipped radio base stations.

    Science.gov (United States)

    Thors, Björn; Thielens, Arno; Fridén, Jonas; Colombi, Davide; Törnevik, Christer; Vermeeren, Günter; Martens, Luc; Joseph, Wout

    2014-05-01

    In this paper, different methods for practical numerical radio frequency exposure compliance assessments of radio base station products were investigated. Both multi-band base station antennas and antennas designed for multiple input multiple output (MIMO) transmission schemes were considered. For the multi-band case, various standardized assessment methods were evaluated in terms of resulting compliance distance with respect to the reference levels and basic restrictions of the International Commission on Non-Ionizing Radiation Protection. Both single frequency and multiple frequency (cumulative) compliance distances were determined using numerical simulations for a mobile communication base station antenna transmitting in four frequency bands between 800 and 2600 MHz. The assessments were conducted in terms of root-mean-squared electromagnetic fields, whole-body averaged specific absorption rate (SAR) and peak 10 g averaged SAR. In general, assessments based on peak field strengths were found to be less computationally intensive, but lead to larger compliance distances than spatial averaging of electromagnetic fields used in combination with localized SAR assessments. For adult exposure, the results indicated that even shorter compliance distances were obtained by using assessments based on localized and whole-body SAR. Numerical simulations, using base station products employing MIMO transmission schemes, were performed as well and were in agreement with reference measurements. The applicability of various field combination methods for correlated exposure was investigated, and best estimate methods were proposed. Our results showed that field combining methods generally considered as conservative could be used to efficiently assess compliance boundary dimensions of single- and dual-polarized multicolumn base station antennas with only minor increases in compliance distances. © 2014 Wiley Periodicals, Inc.

  9. Interference by new-generation mobile phones on critical care medical equipment

    NARCIS (Netherlands)

    van Lieshout, Erik Jan; van der Veer, Sabine N.; Hensbroek, Reinout; Korevaar, Johanna C.; Vroom, Margreeth B.; Schultz, Marcus J.

    2007-01-01

    INTRODUCTION: The aim of the study was to assess and classify incidents of electromagnetic interference (EMI) by second-generation and third-generation mobile phones on critical care medical equipment. METHODS: EMI was assessed with two General Packet Radio Service (GPRS) signals (900 MHz, 2 W, two

  10. Formation of a Refracted Electromagnetic Wave at the Output from a Plane-Parallel Dielectric Layer and Interference Nature of Fermat's Principle

    Science.gov (United States)

    Averbukh, B. B.; Averbukh, I. B.

    2015-04-01

    It is shown that a transition layer representing a spatial region in which field propagation is analogous to refraction in an inhomogeneous medium exists after a dielectric layer. In this region located within the near field zone the direction of the wave vector of the transmitted field varies smoothly, and with increasing distance from the layer, approaches to that of the wave incident on the layer. It is shown that such behavior of the field and occurrence of the transition layer are caused by the interference of the incident wave field and the fields of secondary sources excited in the dielectric by the incident wave field. It is shown that the refraction of the field in a homogeneous medium after the dielectric corresponds to Fermat's principle, and the interference nature of Fermat's principle is justified.

  11. Electromagnetic Compatibility of Devices on Hybrid Electromagnetic Components

    Science.gov (United States)

    Konesev, S. G.; Khazieva, R. T.; Kirillov, R. V.; Gainutdinov, I. Z.; Kondratyev, E. Y.

    2018-01-01

    There is a general tendency to reduce the weight and dimensions, the consumption of conductive and electrical insulating materials, increase the reliability and energy efficiency of electrical devices. In recent years, designers have been actively developing devices based on hybrid electromagnetic components (HEMC) such as inductive-capacitive converters (ICC), voltages pulse generators (VPG), secondary power supplies (SPS), capacitive storage devices (CSD), induction heating systems (IHS). Sources of power supplies of similar electrical devices contain, as a rule, links of increased frequency and function in key (pulse) modes, which leads to an increase in electromagnetic interference (EMI). Nonlinear and periodic (impulse) loads, non-sinusoidal (pulsation) of the electromotive force and nonlinearity of the internal parameters of the source and input circuits of consumers distort the shape of the input voltage lead to an increase in thermal losses from the higher harmonic currents, aging of the insulation, increase in the weight of the power supply filter units, resonance at higher harmonics. The most important task is to analyze the operation of electrotechnical devices based on HEMC from the point of view of creating EMIs and assessing their electromagnetic compatibility (EMC) with power supply systems (PSS). The article presents the results of research on the operation of an IHS, the operation principle of a secondary power supply source of which is based on the operation of a half-bridge autonomous inverter, the switching circuit of which is made in the form of a HEMC, called the «multifunctional integrated electromagnetic component»" (MIEC).

  12. Instruments to assess and measure personal and environmental radiofrequency-electromagnetic field exposures.

    Science.gov (United States)

    Bhatt, Chhavi Raj; Redmayne, Mary; Abramson, Michael J; Benke, Geza

    2016-03-01

    Radiofrequency-electromagnetic field (RF-EMF) exposure of human populations is increasing due to the widespread use of mobile phones and other telecommunication and broadcasting technologies. There are ongoing concerns about potential short- and long-term public health consequences from RF-EMF exposures. To elucidate the RF-EMF exposure-effect relationships, an objective evaluation of the exposures with robust assessment tools is necessary. This review discusses and compares currently available RF-EMF exposure assessment instruments, which can be used in human epidemiological studies. Quantitative assessment instruments are either mobile phone-based (apps/software-modified and hardware-modified) or exposimeters. Each of these tool has its usefulness and limitations. Our review suggests that assessment of RF-EMF exposures can be improved by using these tools compared to the proxy measures of exposure (e.g. questionnaires and billing records). This in turn, could be used to help increase knowledge about RF-EMF exposure induced health effects in human populations.

  13. Instruments to assess and measure personal and environmental radiofrequency-electromagnetic field exposures

    International Nuclear Information System (INIS)

    Bhatt, Chhavi R.; Redmayne, Mary; Abramson, Michael J.; Benke, Geza

    2016-01-01

    Radiofrequency-electromagnetic field (RF-EMF) exposure of human populations is increasing due to the widespread use of mobile phones and other telecommunication and broadcasting technologies. There are ongoing concerns about potential short- and long-term public health consequences from RF-EMF exposures. To elucidate the RF-EMF exposure-effect relationships, an objective evaluation of the exposures with robust assessment tools is necessary. This review discusses and compares currently available RF-EMF exposure assessment instruments, which can be used in human epidemiological studies. Quantitative assessment instruments are either mobile phone-based (apps/software-modified and hardware-modified) or exposimeters. Each of these tool has its usefulness and limitations. Our review suggests that assessment of RF-EMF exposures can be improved by using these tools compared to the proxy measures of exposure (e.g. questionnaires and billing records). This in turn, could be used to help increase knowledge about RF-EMF exposure induced health effects in human populations.

  14. Probabilistic vulnerability assessment of chemical clusters subjected to external acts of interference

    NARCIS (Netherlands)

    Argenti, F.; Landucci, G; Reniers, G.L.L.M.E.

    2016-01-01

    Acts of interference against chemical facilities or chemical clusters might result in severe consequences in
    case of a successful attack (major explosions, fires, toxic dispersions or environmental contamination).
    Although process facilities implement multiple safety barriers to control

  15. Public safety assessment of electromagnetic radiation exposure from mobile base stations.

    Science.gov (United States)

    Alhekail, Z O; Hadi, M A; Alkanhal, M A

    2012-09-01

    Exposure of the general public to electromagnetic radiation originating from randomly selected GSM/WCDMA base stations in Riyadh, Kingdom of Saudi Arabia has been assessed in the context of the International Commission on Non-Ionising Radiation Protection (ICNIRP) guidelines. The purpose of the measurement was to record the maximum power density of signals to estimate possible worst case exposure at each measurement location. These power density measurements were carried out at 60 mobile base stations located in different regions of the city. For each of these sites, three sectors were operational, yielding a total of 180 sectors. Two positions were identified per site with the greatest power density values. Exposures from these base stations were generally found to be in the range of 0.313 to 0.00000149% of the ICNIRP general public reference level, and the greatest exposure near any of the base stations was 21.96 mW m(-2) for a wideband measurement in the 75-3000 MHz frequency range. Analysis of the measured data reveals several trends for different mobile bands with respect to maximum exposure in those locations. Additionally, a simplified calculation method for the electromagnetic fields was used to compare calculated and the measured data. It was determined, on the basis of both results of the measurements and calculations carried out for these selected base stations, that members of the public would not be exposed to in excess of a small fraction of the ICNIRP guidelines at any of those sites. These are first such measurements to be made in the Middle East and provide assurance that exposures in this region of the world do not seem to be any greater than elsewhere.

  16. Unique negative permittivity of the pseudo conducting radial zinc oxide-poly(vinylidene fluoride) nanocomposite film: Enhanced dielectric and electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Aepuru, Radhamanohar [Department of Materials Engineering, Defence Institute of Advanced Technology, Girinagar, Pune 411025 (India); Bhaskara Rao, B.V.; Kale, S.N. [Department of Applied Physics, Defence Institute of Advanced Technology, Pune 411025 (India); Panda, H.S., E-mail: himanshusp@diat.ac.in [Department of Materials Engineering, Defence Institute of Advanced Technology, Girinagar, Pune 411025 (India)

    2015-11-01

    Flower like radial zinc oxide (RZnO) was prepared by using a facile solvothermal method and used to prepare poly(vinylidene fluoride) (PVDF) based nanocomposites. Structural informations of the samples are analyzed by X-ray diffraction and correlated with high resolution transmission electron microscopy along with high annular angular dark field scanning transmission electron microscopy (HAADF-STEM). For the first time, stability studies are carried out by solvent relaxation nuclear magnetic resonance experiments. Dielectric studies of the PVDF and PVDF-RZnO nanocomposites are reported over the wide range of frequency (0.01 Hz–1 MHz) and temperature (25–90 °C). Dielectric property of the PVDF-RZnO nanocomposites was significantly improved wrt filler percentage in PVDF. Unique negative permittivity was observed in the composites having higher filler content (>40 wt%) typically at low frequencies. First time, it is observed that the higher RZnO content in PVDF results the formation of pseudo conducting network and hence improved the electromagnetic shielding efficiency (85%) than PVDF and PVDF-commercial ZnO composites. - Highlights: • Radial ZnO-PVDF nanocomposites were fabricated by using solution casting. • Pseudo conducting network is confirmed through cryo-fracture morphology study. • Stability study of the nano fillers was performed in the polymer matrix. • Unique negative permittivity behavior of the nanocomposites was observed. • EMI shielding property of the radial ZnO-PVDF nanocomposites was performed.

  17. Preliminary feasibility assessment for Earth-to-space electromagnetic (Railgun) launchers

    Science.gov (United States)

    Rice, E. E.; Miller, L. A.; Earhart, R. W.

    1982-01-01

    An Earth to space electromagnetic (railgun) launcher (ESRL) for launching material into space was studied. Potential ESRL applications were identified and initially assessed to formulate preliminary system requirements. The potential applications included nuclear waste disposal in space, Earth orbital applications, deep space probe launchers, atmospheric research, and boost of chemical rockets. The ESRL system concept consisted of two separate railgun launcher tubes (one at 20 deg from the horizontal for Earth orbital missions, the other vertical for solar system escape disposal missions) powered by a common power plant. Each 2040 m launcher tube is surrounded by 10,200 homopolar generator/inductor units to transmit the power to the walls. Projectile masses are 6500 kg for Earth orbital missions and 2055 kg for nuclear waste disposal missions. For the Earth orbital missions, the projectile requires a propulsion system, leaving an estimated payload mass of 650 kg. For the nuclear waste disposal in space mission, the high level waste mass was estimated at 250 kg. This preliminary assessment included technical, environmental, and economic analyses.

  18. A research program to assess the impact of the electromagnetic pulse on electric power systems

    Science.gov (United States)

    McConnell, B. W.; Barnes, P. R.

    A strong electromagnetic pulse (EMP) with an electric-field component on the order of tens of kilovolts per meter is produced by a nuclear detonation in or above the atmosphere. This paper presents an overview and a summary of the results to date of a program formulated to address the research and development of technologies and systems required to assess and reduce the impact of EMP on electric power systems. The technologies and systems being considered include simulation models, methods of assessment, definition of required experiments and data, development of protective hardware, and the creation or revision of operating and control procedures. Results to date include the development of relatively simple unclassified EMP environment models, the development of methods for extending EMP coupling models to the large transmission and distribution network associated with the electric power system, and the performance of a parametric study of HEMP induced surges using an appropriate EMP environment. An experiment to investigate the effect of corona on the coupling of EMP to conductors has been defined and has been performed in an EMP simulator. Experiments to determine the response of key components to simulated EMP surges and an investigation of the impact of steep-front, short-duration impulse on a selected number of the insulation systems used in electric power systems apparatus are being performed.

  19. Amplified fragment length polymorphism analysis to assess crossover interference and homozygosity in gynogenetic diploid Pacific abalone (Haliotis discus hannai).

    Science.gov (United States)

    Nie, H-T; Li, Q; Kong, L-F

    2014-06-01

    Recombination analysis in gynogenetic diploids is a powerful tool for assessing the degree of inbreeding, investigating crossover events and understanding chiasma interference during meiosis. To estimate the marker-centromere recombination rate, the inheritance pattern of 654 amplified fragment length polymorphism (AFLP) markers was examined in the 72-h veliger larvae of two meiogynogenetic diploid families in the Pacific abalone (Haliotis discus hannai). The second-division segregation frequency (y) of the AFLP loci ranged from 0.00 to 0.96, with 23.9% of loci showing y-values higher than 0.67, evidencing the existence of interference. The average recombination frequency across the 654 AFLP loci was 0.45, allowing estimation of the fixation index of 0.55, indicating that meiotic gynogenesis could provide an effective means of rapid inbreeding in the Pacific abalone. The AFLP loci have a small proportion (4.4%) of y-values greater than 0.90, suggesting that a relatively low or intermediate degree of chiasma interference occurred in the abalone chromosomes. The information obtained in this study will enhance our understanding of the abalone genome and will be useful for genetic studies in the species. © 2014 Stichting International Foundation for Animal Genetics.

  20. Electromagnetic Field Assessment as a Smart City Service: The SmartSantander Use-Case.

    Science.gov (United States)

    Diez, Luis; Agüero, Ramón; Muñoz, Luis

    2017-05-31

    Despite the increasing presence of wireless communications in everyday life, there exist some voices raising concerns about their adverse effects. One particularly relevant example is the potential impact of the electromagnetic field they induce on the population's health. Traditionally, very specialized methods and devices (dosimetry) have been used to assess the strength of the E-field, with the main objective of checking whether it respects the corresponding regulations. In this paper, we propose a complete novel approach, which exploits the functionality leveraged by a smart city platform. We deploy a number of measuring probes, integrated as sensing devices, to carry out a characterization embracing large areas, as well as long periods of time. This unique platform has been active for more than one year, generating a vast amount of information. We process such information, and the obtained results validate the whole methodology. In addition, we discuss the variation of the E-field caused by cellular networks, considering additional information, such as usage statistics. Finally, we establish the exposure that can be attributed to the base stations within the scenario under analysis.

  1. Electromagnetic Field Assessment as a Smart City Service: The SmartSantander Use-Case

    Directory of Open Access Journals (Sweden)

    Luis Diez

    2017-05-01

    Full Text Available Despite the increasing presence of wireless communications in everyday life, there exist some voices raising concerns about their adverse effects. One particularly relevant example is the potential impact of the electromagnetic field they induce on the population’s health. Traditionally, very specialized methods and devices (dosimetry have been used to assess the strength of the E-field, with the main objective of checking whether it respects the corresponding regulations. In this paper, we propose a complete novel approach, which exploits the functionality leveraged by a smart city platform. We deploy a number of measuring probes, integrated as sensing devices, to carry out a characterization embracing large areas, as well as long periods of time. This unique platform has been active for more than one year, generating a vast amount of information. We process such information, and the obtained results validate the whole methodology. In addition, we discuss the variation of the E-field caused by cellular networks, considering additional information, such as usage statistics. Finally, we establish the exposure that can be attributed to the base stations within the scenario under analysis.

  2. Assessment of long-term spatio-temporal radiofrequency electromagnetic field exposure.

    Science.gov (United States)

    Aerts, Sam; Wiart, Joe; Martens, Luc; Joseph, Wout

    2018-02-01

    As both the environment and telecommunications networks are inherently dynamic, our exposure to environmental radiofrequency (RF) electromagnetic fields (EMF) at an arbitrary location is not at all constant in time. In this study, more than a year's worth of measurement data collected in a fixed low-cost exposimeter network distributed over an urban environment was analysed and used to build, for the first time, a full spatio-temporal surrogate model of outdoor exposure to downlink Global System for Mobile Communications (GSM) and Universal Mobile Telecommunications System (UMTS) signals. Though no global trend was discovered over the measuring period, the difference in measured exposure between two instances could reach up to 42dB (a factor 12,000 in power density). Furthermore, it was found that, taking into account the hour and day of the measurement, the accuracy of the surrogate model in the area under study was improved by up to 50% compared to models that neglect the daily temporal variability of the RF signals. However, further study is required to assess the extent to which the results obtained in the considered environment can be extrapolated to other geographic locations. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. GLOBAL ELECTROMAGNETIC RADIATION POLLUTION: RISK ASSESSMENT FROM FIELD MEASUREMENTS AND ANIMAL EXPERIMENTS

    Science.gov (United States)

    Fragkopoulou, A. F.; Margaritis, L. H.

    2009-12-01

    The extended use of wireless technology throughout the globe in almost all developed and non-developed countries has forced a large number of scientists to get involved in the investigation of the effects. The major issue is that unlike other forms of radiation exposure, this “non-ionizing electromagnetic radiation” was not present throughout the evolution of life in earth and therefore there are no adaptive mechanisms evolved. All organisms are vulnerable to the possible effects of radiation depending on the actual exposure level. “Safety limits” on the power density have been proposed but ongoing research has shown that these limits are not really safe for humans, not mentioning the entire population of living creatures on earth. The so called “Electrosmog Pollution” originating from the numerous radio and TV stations, communication satellite emission, but most importantly from mobile phone mast antennas, are of major concern, because it is gradually increasing at exponential rate. Therefore the key question is, do living organisms react upon their exposure to fields of non ionizing electromagnetic radiation? To have this question answered extensive research is being performed in various laboratories. One approach of our research includes field measurements within houses and classrooms, since a considerable proportion of the population in each country is exposed to the radiation coming from the nearby mast stations, in order to make a risk assessment. The measurements showed that in many cases the actual radiation present was potentially harmful. In other words, although the measured values were below the national safety levels, nevertheless they were above the levels of other countries. Therefore it has been suggested that a new cellular network should be constructed in order to minimize radiation levels in living areas and schools. Our experimental work is focusing on the elucidation of the effects of non-ionizing EMFs on mice exposed to mobile

  4. High Altitude Electromagnetic Pulse (HEMP) and High Power Microwave (HPM) Devices: Threat Assessments

    National Research Council Canada - National Science Library

    Wilson, Clay

    2006-01-01

    Electromagnetic Pulse (EMP) is an instantaneous, intense energy field that can disrupt at a distance numerous electrical systems and high technology microcircuits that are especially sensitive to power surges...

  5. High Altitude Electromagnetic Pulse (HEMP) and High Power Microwave (HPM) Devices: Threat Assessments

    National Research Council Canada - National Science Library

    Wilson, Clay

    2008-01-01

    Electromagnetic Pulse (EMP) is an instantaneous, intense energy field that can overload or disrupt at a distance numerous electrical systems and high technology microcircuits, which are especially sensitive to power surges...

  6. Mechanical and electromagnetic interference shielding Properties of poly(vinyl alcohol)/graphene and poly(vinyl alcohol)/multi-walled carbon nanotube composite nanofiber mats and the effect of Cu top-layer coating.

    Science.gov (United States)

    Fujimori, Kazushige; Gopiraman, Mayakrishnan; Kim, Han-Ki; Kim, Byoung-Suhk; Kim, Ick-Soo

    2013-03-01

    We report the mechanical property and electromagnetic interference shielding effectiveness (EMI SE) of poly(vinyl alcohol) (PVA)/graphene and PVA/multi-walled carbon nanotube (MWCNT) composite nanofibers prepared by electrospinning. The metal (Cu) was deposited on the resultant PVA composite nanofibers using metal deposition technique in order to improve the mechanical properties and EMI shielding properties. The resulting PVA composite nanofibers and Cu-deposited corresponding nanofibers were characterized by field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and wide angle X-ray diffraction (WAXD). Tensile tests were performed on the PVA/graphene and PVA/MWCNT composite nanofibers. The tensile strength of the PVA/graphene and PVA/MWCNT composite nanofibers was found to be 19.2 +/- 0.3 MPa at graphene content - 6.0 wt% and 12.2 +/- 0.2 MPa at MWCNT content - 3.0 wt%, respectively. The EMI SE of the Cu-deposited PVA/graphene composite nanofibers was significantly improved compared to pure PVA/graphene composite nanofibers, and also depended on the thickness of Cu metal layer deposited on the PVA composite nanofibers.

  7. Circuit modeling for electromagnetic compatibility

    CERN Document Server

    Darney, Ian B

    2013-01-01

    Very simply, electromagnetic interference (EMI) costs money, reduces profits, and generally wreaks havoc for circuit designers in all industries. This book shows how the analytic tools of circuit theory can be used to simulate the coupling of interference into, and out of, any signal link in the system being reviewed. The technique is simple, systematic and accurate. It enables the design of any equipment to be tailored to meet EMC requirements. Every electronic system consists of a number of functional modules interconnected by signal links and power supply lines. Electromagnetic interference

  8. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling.

    Science.gov (United States)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information-inside hotspots or in search of them-based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km2. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. Copyright © 2013 Elsevier Inc. All rights

  9. Engineering Electromagnetics

    International Nuclear Information System (INIS)

    Kim, Se Yun

    2009-01-01

    This book deals with engineering electromagnetics. It contains seven chapters, which treats understanding of engineering electromagnetics such as magnet and electron spin, current and a magnetic field and an electromagnetic wave, Essential tool for engineering electromagnetics on rector and scalar, rectangular coordinate system and curl vector, electrostatic field with coulomb rule and method of electric images, Biot-Savart law, Ampere law and magnetic force, Maxwell equation and an electromagnetic wave and reflection and penetration of electromagnetic plane wave.

  10. Primary Salvage Survey of the Interference of Radiowaves Emitted by Smartphones on Medical Equipment.

    Science.gov (United States)

    Takao, Hiroyuki; Yeh, Yu Chih; Arita, Hiroyuki; Obatake, Takumi; Sakano, Teppei; Kurihara, Minoru; Matsuki, Akira; Ishibashi, Toshihiro; Murayama, Yuichi

    2016-10-01

    Use of mobile phones has become a standard reality of everyday living for many people worldwide, including medical professionals, as data sharing has drastically helped to improve quality of care. This increase in the use of mobile phones within hospitals and medical facilities has raised concern regarding the influence of radio waves on medical equipment. Although comprehensive studies have examined the effects of electromagnetic interference from 2G wireless communication and personal digital cellular systems on medical equipment, similar studies on more recent wireless technologies such as Long Term Evolution, wideband code division multiple access, and high-speed uplink access have yet to be published. Numerous tests targeting current wireless technologies were conducted between December 2012 and March 2013 in an anechoic chamber, shielded from external radio signals, with a dipole antenna to assess the effects of smartphone interference on several types of medical equipment. The interference produced by electromagnetic waves across five frequency bands from four telecommunication standards was assessed on 49 components from 22 pieces of medical equipment. Of the 22 pieces of medical equipment tested, 13 experienced interference at maximum transmission power. In contrast, at minimum transmission power, the maximum interference distance varied from 2 to 5 cm for different wireless devices. Four machines were affected at the minimum transmission power, and the maximum interference distance at the maximum transmission power was 38 cm. Results show that the interference from smartphones on medical equipment is very controllable.

  11. Assessment of Multi-frequency Electromagnetic Induction for Determining Soil Moisture Patterns at the Hillslope Scale

    Science.gov (United States)

    Tromp-van Meerveld, I.; McDonnell, J.

    2009-05-01

    We present an assessment of electromagnetic induction (EM) as a potential rapid and non-invasive method to map soil moisture patterns at the Panola (GA, USA) hillslope. We address the following questions regarding the applicability of EM measurements for hillslope hydrological investigations: (1) Can EM be used for soil moisture measurements in areas with shallow soils?; (2) Can EM represent the temporal and spatial patterns of soil moisture throughout the year?; and (3) can multiple frequencies be used to extract additional information content from the EM approach and explain the depth profile of soil moisture? We found that the apparent conductivity measured with the multi-frequency GEM-300 was linearly related to soil moisture measured with an Aqua-pro capacitance sensor below a threshold conductivity and represented the temporal patterns in soil moisture well. During spring rainfall events that wetted only the surface soil layers the apparent conductivity measurements explained the soil moisture dynamics at depth better than the surface soil moisture dynamics. All four EM frequencies (7290, 9090, 11250, and 14010 Hz) were highly correlated and linearly related to each other and could be used to predict soil moisture. This limited our ability to use the four different EM frequencies to obtain a soil moisture profile with depth. The apparent conductivity patterns represented the observed spatial soil moisture patterns well when the individually fitted relationships between measured soil moisture and apparent conductivity were used for each measurement point. However, when the same (master) relationship was used for all measurement locations, the soil moisture patterns were smoothed and did not resemble the observed soil moisture patterns very well. In addition, the range in calculated soil moisture values was reduced compared to observed soil moisture. Part of the smoothing was likely due to the much larger measurement area of the GEM-300 compared to the Aqua

  12. Performance Assessment of Low-Temperature Thermal Storage with Electromagnetic Control

    Directory of Open Access Journals (Sweden)

    Ya-Wei Lee

    2014-08-01

    Full Text Available This study presents electromagnetic-controlled thermal storage (ECTS that can be directly implemented in strategies of low-temperature waste heat recovery for energy-consuming equipment. A magnetic nanofluid (MNF prepared from fine iron ferrite ferromagnetic particles is recommended as a latent heat medium (LHM. During electromagnetic induction, local flow fluctuations are generated and thermal convection in the MNF can be enhanced. The achieved results demonstrated that ECTS has a wide operational range and an optimum storage efficiency of 84.46%. Thus, a self-perturbation mode used to enhance thermal energy transportation can be designed for numerous waste heat management applications.

  13. Assessing segmentation processes by click detection: online measure of statistical learning, or simple interference?

    Science.gov (United States)

    Franco, Ana; Gaillard, Vinciane; Cleeremans, Axel; Destrebecqz, Arnaud

    2015-12-01

    Statistical learning can be used to extract the words from continuous speech. Gómez, Bion, and Mehler (Language and Cognitive Processes, 26, 212-223, 2011) proposed an online measure of statistical learning: They superimposed auditory clicks on a continuous artificial speech stream made up of a random succession of trisyllabic nonwords. Participants were instructed to detect these clicks, which could be located either within or between words. The results showed that, over the length of exposure, reaction times (RTs) increased more for within-word than for between-word clicks. This result has been accounted for by means of statistical learning of the between-word boundaries. However, even though statistical learning occurs without an intention to learn, it nevertheless requires attentional resources. Therefore, this process could be affected by a concurrent task such as click detection. In the present study, we evaluated the extent to which the click detection task indeed reflects successful statistical learning. Our results suggest that the emergence of RT differences between within- and between-word click detection is neither systematic nor related to the successful segmentation of the artificial language. Therefore, instead of being an online measure of learning, the click detection task seems to interfere with the extraction of statistical regularities.

  14. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    Energy Technology Data Exchange (ETDEWEB)

    Aerts, Sam, E-mail: sam.aerts@intec.ugent.be; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-10-15

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km{sup 2}. In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  15. Assessment of outdoor radiofrequency electromagnetic field exposure through hotspot localization using kriging-based sequential sampling

    International Nuclear Information System (INIS)

    Aerts, Sam; Deschrijver, Dirk; Verloock, Leen; Dhaene, Tom; Martens, Luc; Joseph, Wout

    2013-01-01

    In this study, a novel methodology is proposed to create heat maps that accurately pinpoint the outdoor locations with elevated exposure to radiofrequency electromagnetic fields (RF-EMF) in an extensive urban region (or, hotspots), and that would allow local authorities and epidemiologists to efficiently assess the locations and spectral composition of these hotspots, while at the same time developing a global picture of the exposure in the area. Moreover, no prior knowledge about the presence of radiofrequency radiation sources (e.g., base station parameters) is required. After building a surrogate model from the available data using kriging, the proposed method makes use of an iterative sampling strategy that selects new measurement locations at spots which are deemed to contain the most valuable information—inside hotspots or in search of them—based on the prediction uncertainty of the model. The method was tested and validated in an urban subarea of Ghent, Belgium with a size of approximately 1 km 2 . In total, 600 input and 50 validation measurements were performed using a broadband probe. Five hotspots were discovered and assessed, with maximum total electric-field strengths ranging from 1.3 to 3.1 V/m, satisfying the reference levels issued by the International Commission on Non-Ionizing Radiation Protection for exposure of the general public to RF-EMF. Spectrum analyzer measurements in these hotspots revealed five radiofrequency signals with a relevant contribution to the exposure. The radiofrequency radiation emitted by 900 MHz Global System for Mobile Communications (GSM) base stations was always dominant, with contributions ranging from 45% to 100%. Finally, validation of the subsequent surrogate models shows high prediction accuracy, with the final model featuring an average relative error of less than 2 dB (factor 1.26 in electric-field strength), a correlation coefficient of 0.7, and a specificity of 0.96. -- Highlights: • We present an

  16. Assessment methodology of counter-personnel high power electromagnetic millimeter wave effects

    NARCIS (Netherlands)

    Valente, F.; Horst, M.J. van der; Paulissen, J.J.M.; Zwamborn, A.P.M.; Toet, A.

    2013-01-01

    The group of NLW that arguably offers the largest amount of useful applications are based on high power electromagnetic millimetre wave technology. This group is often referred to as ‘Active Denial Systems’ (ADS), since they are primarily aimed at deterring and dispersing people out of an area. The

  17. Risk assessment of electromagnetic fields exposure with metallic orthopedic implants: a cadaveric study.

    Science.gov (United States)

    Crouzier, D; Selek, L; Martz, B-A; Dabouis, V; Arnaud, R; Debouzy, J-C

    2012-02-01

    Metallic materials are well known to strongly interact with electromagnetic fields. While biological effects of such field have been extensively studied, only few works dealt with the interactions of electromagnetic waves with passive metallic device implanted in biological system. Hence only several numerical and phantom simulation studies were focusing on this aspect, whereas no in situ anatomic experiment has been previously performed. In this study the effect of electromagnetic waves on eight different orthopaedic medical devices (six plates from 55 to 318mm length, a total knee and a total hip prosthesis) were explored on six human cadavers. To mimic a random environmental exposure resulting from the most common frequencies band used in domestic environment and medical applications (TV and radio broadcasting, cell phone communication, MRI, diathermy treatment), a multifrequency generator emitting in VHF, UHF, GSM and GCS frequency bands was used. The different medical devices were exposed to an electromagnetic field at 50W/m(2) and 100W/m(2). After 6min exposure, the temperature was measured on three points close to each medical device, and the induced currents were estimated. No significant temperature increase (<0.2°C) was finally detected; beside, a slight induced tension (up to 1.1V) was recorded but would appear too low to induce any biological side effect. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  18. Preliminary assessment of the electromagnetic environment in the immediate vicinity of the ETA accelerator

    International Nuclear Information System (INIS)

    Cabayan, H.S.; Bogdan, E.; Zicker, J.; Wythe, D.; Burke, G.J.

    1980-04-01

    The electromagnetic fields in the immediate vicinity of the Experimental Test Accelerator (ETA) at the Lawrence Livermore Laboratory have been characterized. Various EM sensors that cover the frequency band from the very low frequencies up into the GHz region have been used. The report describes in detail the probes, the test set-up and the data processing techniques

  19. Assessment of reverberation time by two measurement systems for room electromagnetics analysis

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Plets, David

    2011-01-01

    A closed room environment is viewed as a lossy cavity, characterized by possibly a line of sight (LOS) component and diffuse scattering parts from walls and internal obstacles. A theory used in acoustics and reverberation chambers is applied for the electromagnetics case, and main issues related...

  20. Quantum Interference and Coherence Theory and Experiments

    CERN Document Server

    Ficek, Zbigniew; Rhodes, William T; Asakura, Toshimitsu; Brenner, Karl-Heinz; Hänsch, Theodor W; Kamiya, Takeshi; Krausz, Ferenc; Monemar, Bo; Venghaus, Herbert; Weber, Horst; Weinfurter, Harald

    2005-01-01

    For the first time, this book assembles in a single volume accounts of many phenomena involving quantum interference in optical fields and atomic systems. It provides detailed theoretical treatments and experimental analyses of such phenomena as quantum erasure, quantum lithography, multi-atom entanglement, quantum beats, control of decoherence, phase control of quantum interference, coherent population trapping, electromagnetically induced transparency and absorption, lasing without inversion, subluminal and superluminal light propagation, storage of photons, quantum interference in phase space, interference and diffraction of cold atoms, and interference between Bose-Einstein condensates. This book fills a gap in the literature and will be useful to both experimentalists and theoreticians.

  1. Electromagnetic Waves

    DEFF Research Database (Denmark)

    This book is dedicated to various aspects of electromagnetic wave theory and its applications in science and technology. The covered topics include the fundamental physics of electromagnetic waves, theory of electromagnetic wave propagation and scattering, methods of computational analysis......, material characterization, electromagnetic properties of plasma, analysis and applications of periodic structures and waveguide components, etc....

  2. Measuring pain phenomena after spinal cord injury: Development and psychometric properties of the SCI-QOL Pain Interference and Pain Behavior assessment tools.

    Science.gov (United States)

    Cohen, Matthew L; Kisala, Pamela A; Dyson-Hudson, Trevor A; Tulsky, David S

    2018-05-01

    To develop modern patient-reported outcome measures that assess pain interference and pain behavior after spinal cord injury (SCI). Grounded-theory based qualitative item development; large-scale item calibration field-testing; confirmatory factor analyses; graded response model item response theory analyses; statistical linking techniques to transform scores to the Patient Reported Outcome Measurement Information System (PROMIS) metric. Five SCI Model Systems centers and one Department of Veterans Affairs medical center in the United States. Adults with traumatic SCI. N/A. Spinal Cord Injury - Quality of Life (SCI-QOL) Pain Interference item bank, SCI-QOL Pain Interference short form, and SCI-QOL Pain Behavior scale. Seven hundred fifty-seven individuals with traumatic SCI completed 58 items addressing various aspects of pain. Items were then separated by whether they assessed pain interference or pain behavior, and poorly functioning items were removed. Confirmatory factor analyses confirmed that each set of items was unidimensional, and item response theory analyses were used to estimate slopes and thresholds for the items. Ultimately, 7 items (4 from PROMIS) comprised the Pain Behavior scale and 25 items (18 from PROMIS) comprised the Pain Interference item bank. Ten of these 25 items were selected to form the Pain Interference short form. The SCI-QOL Pain Interference item bank and the SCI-QOL Pain Behavior scale demonstrated robust psychometric properties. The Pain Interference item bank is available as a computer adaptive test or short form for research and clinical applications, and scores are transformed to the PROMIS metric.

  3. Evaluation of Nanocomposites for Shielding Electromagnetic Interference

    Science.gov (United States)

    2011-09-01

    ESD Electrostatic Discharge FAA Federal Aviation Administration FRP Fiberglass Reinforced Plastic GCR Galactic Cosmic Radiation GSM Grams...debris currently being tracked by the National Aeronautics and Space Administration (NASA), the Federal Aviation Administration (FAA), and North...stripped away as the atom accelerated in interstellar space to speeds approaching the speed of light and eventually, only the nucleus of the atom

  4. Carbon nanostructure composite for electromagnetic interference ...

    Indian Academy of Sciences (India)

    Department of Applied Physics, Defence Institute of Advanced Technology (DU), ... are performed at different frequencies and methods of processing the ..... Work has also been done on activation of the surface of carbon fibre using chemical ..... 3 kHz to 300 GHz, Institute of Electrical and Electonics Engineers, Incorporated.

  5. Methodology to assess the effects of magnetohydrodynamic electromagnetic pulse (MHD-EMP) on power systems

    International Nuclear Information System (INIS)

    Legro, J.R.; Abi-Samra, N.C.; Crouse, J.C.; Tesche, F.M.

    1985-01-01

    This paper summarizes a method to evaluate the possible effects of magnetohydrodynamic-electromagnetic pulse (MHD-EMP) on power systems. This method is based on the approach adapted to study the impact of geomagnetic storms on power systems. The paper highlights the similarities and differences between the two phenomena. Also presented are areas of concern which are anticipated from MHD-EMP on the overall system operation. 12 refs., 1 fig

  6. Assessment and mitigation of electromagnetic pulse (EMP) impacts at short-pulse laser facilities

    International Nuclear Information System (INIS)

    Brown, C G Jr; Bond, E; Clancy, T; Dangi, S; Eder, D C; Ferguson, W; Kimbrough, J; Throop, A

    2010-01-01

    The National Ignition Facility (NIF) will be impacted by electromagnetic pulse (EMP) during normal long-pulse operation, but the largest impacts are expected during short-pulse operation utilizing the Advanced Radiographic Capability (ARC). Without mitigation these impacts could range from data corruption to hardware damage. We describe our EMP measurement systems on Titan and NIF and present some preliminary results and thoughts on mitigation.

  7. Processing and inversion of commercial helicopter time-domain electromagnetic data for environmental assessments and geologic and hydrologic mapping

    DEFF Research Database (Denmark)

    J.E., Podgorski; Auken, Esben; Schamper, Cyril Noel Clarence

    2013-01-01

    Helicopter time-domain electromagnetic (HTEM) surveying has historically been used for mineral exploration, but over the past decade it has started to be used in environmental assessments and geologic and hydrologic mapping. Such surveying is a cost-effective means of rapidly acquiring densely......%-23%, and the artificial lineations were practically eliminated. Our processing and inversion strategy is entirely general, such that with minor system-specific modifications it could be applied to any HTEM data set, including those recorded many years ago. © 2013 Society of Exploration Geophysicists....

  8. Combined Borehole Seismic and Electromagnetic Inversion For High-Resolution Petrophysical Assessment Of Hydocarbon Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Carlos Torres-Verdin; G. Michael Hoversten; Ki Ha Lee; Gregory Newman; Kurt Nihei

    2008-12-31

    This report summarizes the work performed between January 2005 and December 2007, under DOE research contract DE-FC26-04NT15507. The project is was performed by the Center for Petroleum and Geosystems Engineering of The University of Texas at Austin and Lawrence Berkeley National Laboratory under the auspices of the National Energy Technology Office (NETL) and the Strategic Center for Natural Gas and Oil (SCNGO). During the three-year project, we developed new methods to combine borehole sonic and electromagnetic (EM) measurements for the improved assessment of elastic and petrophysical properties of rock formations penetrated by a well. Sonic measurements consisted of full waveform acoustic amplitudes acquired with monopole and dipole sources, whereas EM measurements consisted of frequency-domain voltages acquired with multi-coil induction systems. The combination of sonic and EM measurements permitted the joint estimation of elastic and petrophysical properties in the presence of mud-filtrate invasion. It was conclusively shown that the combined interpretation of sonic and EM measurements reduced non-uniqueness in the estimation of elastic and petrophysical properties and improved the spatial resolution of the estimations compared to estimations yielded separately from the two types of measurements. Moreover, this approach enabled the assessment of dynamic petrophysical properties such as permeability, as it incorporated the physics of mud-filtrate invasion in the interpretation of the measurements. The first part of the project considered the development of fast and reliable numerical algorithms to simulate borehole sonic waveforms in 2D, 3D, and radial 1D media. Such algorithms were subsequently used in the quantitative estimation of elastic properties jointly from borehole sonic and EM measurements. In the second part of the project we developed a new algorithm to estimate water saturation, porosity, and dry-rock elastic moduli jointly from borehole sonic and

  9. Can cancer patients assess the influence of pain on functions? A randomised, controlled study of the pain interference items in the Brief Pain Inventory

    Directory of Open Access Journals (Sweden)

    Kaasa Stein

    2007-03-01

    Full Text Available Abstract Background The Brief Pain Inventory (BPI is recommended as a pain measurement tool by the Expert Working Group of the European Association of Palliative Care. The BPI is designed to assess both pain severity and interference with functions caused by pain. The purpose of this study was to investigate if pain interference items are influenced by other factors than pain. Methods We asked adult cancer patients to complete the original and a revised BPI on two study days. In the original version of the BPI the patients were asked how, during the last 24 hours, pain has interfered with functions. In the revised BPI this question was changed to how, during the last 24 hours, these functions are affected in general. Heath related quality of life was assessed at both study days applying the European Organization for Research and Treatment of Cancer quality of life questionnaire. Results Forty-eight of the 55 included patients completed both assessments. The BPI pain intensities scores and the health related quality of life scores were similar at the two study days. Except for mood this study observed no significant distinctions between the patients' BPI interference items scores in the original (pain influence on function and the revised BPI (function in general. Seventeen patients reported higher influence from pain on functions than the total influence on function from all causes. Conclusion We observed similar scores in the original BPI interference scores (pain influence on function compared with the revised BPI interference scores (decreased function in general. This finding might imply that the BPI interference scale measures are partly responded to as more of a global interference measure.

  10. Assessment of Potential Impact of Electromagnetic Fields from Undersea Cable on Migratory Fish Behavior

    Energy Technology Data Exchange (ETDEWEB)

    Klimley, A. P. [Univ. of California, Davis, CA (United States); Wyman, M. T. [Univ. of California, Davis, CA (United States); Kavet, Rob [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States)

    2016-09-28

    The US Department of Energy and US Department of the Interior, Bureau of Ocean Energy Management commissioned this study to address the limited scientific data on the impacts of high voltage direct current cables on aquatic biota, in particular migratory species within the San Francisco Bay. Empirical evidence exists that marine animals perceive and orient to local distortions in the earth’s main geomagnetic field magnetic field. The electromagnetic fields (EMF) generated by the cables that carry electricity from hydrokinetic energy sources to shore-based power stations may produce similar local distortions in the earth’s main field. Concern exists that animals that migrate along the continental shelves might orient to the EMF from the cables, and move either inshore or offshore away from their normal path. The Trans Bay Cable (TBC) is a ±200-kilovolt (kV), 400 MW 85-km long High Voltage Direct Current (DC) buried transmission line linking Pittsburg, CA with San Francisco, CA (SF) through the San Francisco Bay. The study addresses the following specific questions based on measurements and projections of the EMF produced by an existing marine cable, the TBC, in San Francisco Bay. Specifically, does the presence of EMF from an operating power cable alter the behavior and path of bony fishes and sharks along a migratory corridor? Does the EMF from an operating power cable guide migratory movements or pose an obstacle to movement? To meet the main study objectives several activities needed to be carried out: 1) modeling of the magnetic fields produced by the TBC, 2) assessing the migratory impacts on Chinook salmon smolts (Oncorhynchus tshawytscha) and green sturgeon (Acipenser medirostris) as a result of local magnetic field distortions produced by bridge structures and 3) analyzing behavioral responses by migratory Chinook salmon and green sturgeon to a high-voltage power cable. To meet the first objective, magnetic field measurements were made using two

  11. Pilot study trialling a new ambulatory method for the clinical assessment of regional gastrointestinal transit using multiple electromagnetic capsules.

    Science.gov (United States)

    Haase, A M; Gregersen, T; Schlageter, V; Scott, M S; Demierre, M; Kucera, P; Dahlerup, J F; Krogh, K

    2014-12-01

    Gastrointestinal (GI) motor disorders often involve several regions of the GI tract. Therefore, easy and safe assessment of whole gut and regional motility is valuable for more precise diagnosis. 3D-Transit is a novel method for ambulatory evaluation of total and regional gastrointestinal transit times (GITT) based on the anatomical localization of ingestible electromagnetic capsules. The main purpose of this study was to test the performance of the 3D-Transit system. Twenty healthy volunteers each ingested three electromagnetic capsules over a period of two consecutive days. Standard radio-opaque markers (ROM) were also ingested to assess the agreement between total GITT obtained with both methods. Investigations were well-tolerated and three capsules could be tracked simultaneously with minimal data loss (Capsule 1: median: 0.2% of time (range 0-25.3%). Region specific contraction patterns were identified and used for computation of total and regional GITT in all subjects. Inter-observer agreement was 100% for total GITT (median variation 0%) but less for regional GITT. Day-to-day and diurnal variations were significant for total and regional GITT. Total GITT assessed by 3D-Transit capsules were moderately well-correlated to those assessed with standard ROM (Spearman's rho = 0.7). 3D-transit is a well-tolerated and minimal invasive ambulatory method for assessment of GI motility. By providing both total and regional transit times, the 3D-Transit system holds great promise for future clinical studies of GI function in health and disease. © 2014 John Wiley & Sons Ltd.

  12. Electromagnetic Compatibility Design of the Computer Circuits

    Science.gov (United States)

    Zitai, Hong

    2018-02-01

    Computers and the Internet have gradually penetrated into every aspect of people’s daily work. But with the improvement of electronic equipment as well as electrical system, the electromagnetic environment becomes much more complex. Electromagnetic interference has become an important factor to hinder the normal operation of electronic equipment. In order to analyse the computer circuit compatible with the electromagnetic compatibility, this paper starts from the computer electromagnetic and the conception of electromagnetic compatibility. And then, through the analysis of the main circuit and system of computer electromagnetic compatibility problems, we can design the computer circuits in term of electromagnetic compatibility. Finally, the basic contents and methods of EMC test are expounded in order to ensure the electromagnetic compatibility of equipment.

  13. Measurement and assessment of electromagnetic fields near radiophones in line with provisions of European Directive 2013/35/EU and Polish labour law

    Directory of Open Access Journals (Sweden)

    Krzysztof Gryz

    2013-10-01

    Full Text Available Background: The activities of rescue and uniformed services require the use of wireless communication devices, such as portable radiophones. Assessment of workers' exposure to electromagnetic fields emitted by radiophones is important in view of occupational safety and health (OSH, legislation requirements and reports on possible adverse health effects in users of devices emitting radiofrequency electromagnetic field. Materials and Methods: In this study 50 portable radiophones of conventional and trunked communication systems were investigated. The assessment of electromagnetic hazards to users involved unperturbed electromagnetic field measurements near radiophones' antennas. Results: The electric field strength corresponding to the occupational exposure level (fields of so-called safety zones established by OSH legislation in Poland was measured at a distance of 45-65 cm from the portable radiophones antennas of conventional system and 75-95 cm from antennas of trunked system radiophones, depending on their type and mode of work. The assessment was based on the averaged results of series of measurements. The electric field strength exceeding action levels defined by Directive 2013/35/EU was found up to 15 cm from radiophone antennas of conventional system and up to 10 cm from the antennas of trunked system radiophones. Conclusions: Taking into account the range of safety zones and the use of portable radiophones near the body, their users should be classified into the group of workers occupationally exposed to electromagnetic fields. Electromagnetic field measurement results and typical conditions of using portable radiophones justify theneed for additional assessment of electromagnetic hazards - the analysis of compliance with relevant exposure limit values provided by Directive 2013/35/EU. Med Pr 2013;64(5:671–680

  14. Systematic Identification and Assessment of Therapeutic Targets for Breast Cancer Based on Genome-Wide RNA Interference Transcriptomes

    Directory of Open Access Journals (Sweden)

    Yang Liu

    2017-02-01

    Full Text Available With accumulating public omics data, great efforts have been made to characterize the genetic heterogeneity of breast cancer. However, identifying novel targets and selecting the best from the sizeable lists of candidate targets is still a key challenge for targeted therapy, largely owing to the lack of economical, efficient and systematic discovery and assessment to prioritize potential therapeutic targets. Here, we describe an approach that combines the computational evaluation and objective, multifaceted assessment to systematically identify and prioritize targets for biological validation and therapeutic exploration. We first establish the reference gene expression profiles from breast cancer cell line MCF7 upon genome-wide RNA interference (RNAi of a total of 3689 genes, and the breast cancer query signatures using RNA-seq data generated from tissue samples of clinical breast cancer patients in the Cancer Genome Atlas (TCGA. Based on gene set enrichment analysis, we identified a set of 510 genes that when knocked down could significantly reverse the transcriptome of breast cancer state. We then perform multifaceted assessment to analyze the gene set to prioritize potential targets for gene therapy. We also propose drug repurposing opportunities and identify potentially druggable proteins that have been poorly explored with regard to the discovery of small-molecule modulators. Finally, we obtained a small list of candidate therapeutic targets for four major breast cancer subtypes, i.e., luminal A, luminal B, HER2+ and triple negative breast cancer. This RNAi transcriptome-based approach can be a helpful paradigm for relevant researches to identify and prioritize candidate targets for experimental validation.

  15. Scattering of light and other electromagnetic radiation

    CERN Document Server

    Kerker, Milton

    1969-01-01

    The Scattering of Light and Other Electromagnetic Radiation discusses the theory of electromagnetic scattering and describes some practical applications. The book reviews electromagnetic waves, optics, the interrelationships of main physical quantities and the physical concepts of optics, including Maxwell's equations, polarization, geometrical optics, interference, and diffraction. The text explains the Rayleigh2 theory of scattering by small dielectric spheres, the Bessel functions, and the Legendre functions. The author also explains how the scattering functions for a homogenous sphere chan

  16. Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models

    International Nuclear Information System (INIS)

    Kuehn, Sven; Jennings, Wayne; Christ, Andreas; Kuster, Niels

    2009-01-01

    The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child to large adult male by numerical modeling. We address the exposure to plane-waves incident from all major six sides of the humans with two orthogonal polarizations each. Worst-case scattered field exposure scenarios have been constructed in order to test the implemented procedures of current in situ compliance measurement standards (spatial averaging versus peak search). Our findings suggest that the reference levels of current electromagnetic (EM) safety guidelines for demonstrating compliance as well as some of the current measurement standards are not consistent with the basic restrictions and need to be revised.

  17. Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, Sven; Jennings, Wayne; Christ, Andreas; Kuster, Niels [Foundation for Research on Information Technologies in Society (IT' IS), Zuerich (Switzerland)], E-mail: kuehn@itis.ethz.ch

    2009-02-21

    The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child to large adult male by numerical modeling. We address the exposure to plane-waves incident from all major six sides of the humans with two orthogonal polarizations each. Worst-case scattered field exposure scenarios have been constructed in order to test the implemented procedures of current in situ compliance measurement standards (spatial averaging versus peak search). Our findings suggest that the reference levels of current electromagnetic (EM) safety guidelines for demonstrating compliance as well as some of the current measurement standards are not consistent with the basic restrictions and need to be revised.

  18. Systematic Standardized and Individualized Assessment of Masticatory Cycles Using Electromagnetic 3D Articulography and Computer Scripts

    Directory of Open Access Journals (Sweden)

    Ramón Fuentes

    2017-01-01

    Full Text Available Masticatory movements are studied for decades in odontology; a better understanding of them could improve dental treatments. The aim of this study was to describe an innovative, accurate, and systematic method of analyzing masticatory cycles, generating comparable quantitative data. The masticatory cycles of 5 volunteers (Class I, 19 ± 1.7 years without articular or dental occlusion problems were evaluated using 3D electromagnetic articulography supported by MATLAB software. The method allows the trajectory morphology of the set of chewing cycles to be analyzed from different views and angles. It was also possible to individualize the trajectory of each cycle providing accurate quantitative data, such as number of cycles, cycle areas in frontal view, and the ratio between each cycle area and the frontal mandibular border movement area. There was a moderate negative correlation (−0.61 between the area and the number of cycles: the greater the cycle area, the smaller the number of repetitions. Finally it was possible to evaluate the area of the cycles through time, which did not reveal a standardized behavior. The proposed method provided reproducible, intelligible, and accurate quantitative and graphical data, suggesting that it is promising and may be applied in different clinical situations and treatments.

  19. Electromagnetic articulography assessment of articulatory function in adults with dysarthria following traumatic brain injury.

    Science.gov (United States)

    Kuruvilla, Mili; Murdoch, Bruce; Goozèe, Justine

    2007-06-01

    To explore articulatory kinematic differences between normal and dysarthric speakers post-traumatic brain injury (TBI) during syllable and sentence productions. A comparison between the control, mild (MTBI) and severe TBI groups for all measured kinematic parameters was carried out using the Kruskal Wallis test. Ten participants with a severe TBI and six post-MTBI formed the experimental group. The control group consisted of 14 age and sex matched non-neurologically impaired speakers. Articulatory kinematic profiles for the three groups were obtained using the Electromagnetic Articulograph (EMA) while repeating sentence and syllable embedded /t/ and /k/ productions at a habitual rate and loudness level. Significant differences between the severe TBI and control group were identified only for the release phase of the /t/ sentence productions wherein an increase in mean maximum acceleration was observed for the severe TBI group. While a simple syllable repetition task at a moderate rate was unable to differentiate the three groups, a complex sentence production task precipitated an increase in mean maximum acceleration which may be indicative of increased articulatory effort and impaired speech motor control even at a convenient rate for the severe group.

  20. Fluorescence Sensors for Early Detection of Nitrification in Drinking Water Distribution Systems - Interference Corrections and Feasibility Assessment

    Science.gov (United States)

    Do, T. D.; Pifer, A.; Chowdhury, Z.; Wahman, D.; Zhang, W.; Fairey, J.

    2017-12-01

    Detection of nitrification events in chloraminated drinking water distribution systems remains an ongoing challenge for many drinking water utilities, including Dallas Water Utilities (DWU) and the City of Houston (CoH). Each year, these utilities experience nitrification events that necessitate extensive flushing, resulting in the loss of billions of gallons of finished water. Biological techniques used to quantify the activity of nitrifying bacteria are impractical for real-time monitoring because they require significant laboratory efforts and/or lengthy incubation times. At present, DWU and CoH regularly rely on physicochemical parameters including total chlorine and monochloramine residual, and free ammonia, nitrite, and nitrate as indicators of nitrification, but these metrics lack specificity to nitrifying bacteria. To improve detection of nitrification in chloraminated drinking water distribution systems, we seek to develop a real-time fluorescence-based sensor system to detect the early onset of nitrification events by measuring the fluorescence of soluble microbial products (SMPs) specific to nitrifying bacteria. Preliminary data indicates that fluorescence-based metrics have the sensitivity to detect these SMPs in the early stages of nitrification, but several remaining challenges will be explored in this presentation. We will focus on benchtop and sensor results from ongoing batch and annular reactor experiments designed to (1) identify fluorescence wavelength pairs and data processing techniques suitable for measurement of SMPs from nitrification and (2) assess and correct potential interferences, such as those from monochloramine, pH, iron, nitrite, nitrate and humic substances. This work will serve as the basis for developing fluorescence sensor packages for full-scale testing and validation in the DWU and CoH systems. Findings from this research could be leveraged to identify nitrification events in their early stages, facilitating proactive

  1. LONG-TERM ELECTROMAGNETIC FIELD MEASUREMENT AND ASSESSMENT FOR A SHOPPING MALL.

    Science.gov (United States)

    Engiz, Begum Korunur; Kurnaz, Cetin

    2017-07-01

    As a result of the dense deployment of wireless devices and base stations, measuring and evaluating the electromagnetic (EM) exposure levels they emit have become important to human health especially if they exceed the limits defined in the standards. Base stations, Wi-Fi equipment and other electronic devices are used heavily, especially in densely crowded places like shopping centers. In this study, electric field strength (E) measurements were conducted at one of the largest shopping malls in Turkey. Broadband E measurements were performed using PMM 8053 EM field strength meter for 24 h a day for the duration of one week while frequency selective measurements were carried out with SRM-3006 EM field strength meter. It is concluded from the measurements that the mean measured total E in the band between 100 kHz and 3 GHz is 0.59 V/m while the maximum E is 7.88 V/m, which are both below the limit determined by International Commission on Non-Ionizing Radiation Protection. Evolutions show that E can increase by up to 55% during the daytime. Analyses demonstrate that 71.3% of total E is caused by UMTS2100, 16.3% is produced by GSM900, 6.2% by LTE, 3.5% by Wi-Fi, and 2.7% is generated by devices that use the remaining frequency bands. Based on the detailed statistical analysis of long-term E measurement results, it can be concluded that the measured E levels are not in normal distribution and that they are statistically different with respect to days. Furthermore, distribution of E can be best modeled with the non-parametric approach. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Assessment of marine gas hydrate deposits: A comparative study of seismic, electromagnetic and seafloor compliance methods

    Energy Technology Data Exchange (ETDEWEB)

    Willoughby, E. C.; Schwalenberg, K.; Edwards, R.N.; Spence, G.D.; Hyndman, R.D.

    2005-07-01

    The existence, distribution and concentration of marine natural gas hydrate are mostly diagnosed using seismic data. The base of the hydrate stability zone marks an acoustic impedance contrast, which generally mimics seafloor topography and is associated with a bright, negative-polarity reflector, known as the Bottom Simulating Reflector (BSR). However, limitations of seismic methods include uncertainty in the origin of the BSR, which does not distinguish between low velocity gas and high velocity hydrate, blanking, and lack of clear upper boundary reflections. Sufficiently accurate hydrate layer velocities have been obtained at few sites, and these could better evaluate hydrate content with reference to velocities in similar sediments without hydrate- a situation very difficult to find. Therefore, estimation of the total mass of a deposit is difficult using seismic data alone. We have developed two supplementary geophysical imaging techniques for the evaluation of marine hydrate: A deep-towed controlled-source electromagnetic (CSEM) and a seafloor compliance experiment. These methods are sensitive to physical properties of the sedimentary section, which are modified by the presence of gas hydrate, namely the resistivity and the bulk shear modulus depth profile, respectively. CSEM data are gathered by inline receivers towed behind an AC transmitter; high precision timing allows measurement of the EM field propagation time through marine sediments which is proportional to resistivity, which is increased by the presence of insulating hydrate. Seafloor compliance is the transfer function between pressure induced on the seafloor by surface gravity waves and the associated deformation of the seafloor. It is mostly sensitive to shear modulus anomalies. Shear modulus is increased by hydrates, which can cement grains together. Here we present field data at a gas hydrate site, south of ODP Hole 889B in northern Cascadia, over a proposed new IODP transect, where these three

  3. Long-term electromagnetic field measurement and assessment for a shopping mall

    International Nuclear Information System (INIS)

    Engiz, Begum Korunur; Kurnaz, Cetin

    2017-01-01

    As a result of the dense deployment of wireless devices and base stations, measuring and evaluating the electromagnetic (EM) exposure levels they emit have become important to human health especially if they exceed the limits defined in the standards. Base stations, Wi-Fi equipment and other electronic devices are used heavily, especially in densely crowded places like shopping centers. In this study, electric field strength (E) measurements were conducted at one of the largest shopping malls in Turkey. Broadband E measurements were performed using PMM 8053 EM field strength meter for 24 h a day for the duration of one week while frequency selective measurements were carried out with SRM 3006 EM field strength meter. It is concluded from the measurements that the mean measured total E in the band between 100 kHz and 3 GHz is 0.59 V/m while the maximum E is 7.88 V/m, which are both below the limit determined by International Commission on Non-Ionizing Radiation Protection. Evolutions show that E can increase by up to 55% during the daytime. Analyses demonstrate that 71.3% of total E is caused by UMTS2100, 16.3% is produced by GSM900, 6.2% by LTE, 3.5% by Wi-Fi, and 2.7% is generated by devices that use the remaining frequency bands. Based on the detailed statistical analysis of long-term E measurement results, it can be concluded that the measured E levels are not in normal distribution and that they are statistically different with respect to days. Furthermore, distribution of E can be best modeled with the non-parametric approach. (authors)

  4. Assessing the impact of large-scale computing on the size and complexity of first-principles electromagnetic models

    International Nuclear Information System (INIS)

    Miller, E.K.

    1990-01-01

    There is a growing need to determine the electromagnetic performance of increasingly complex systems at ever higher frequencies. The ideal approach would be some appropriate combination of measurement, analysis, and computation so that system design and assessment can be achieved to a needed degree of accuracy at some acceptable cost. Both measurement and computation benefit from the continuing growth in computer power that, since the early 1950s, has increased by a factor of more than a million in speed and storage. For example, a CRAY2 has an effective throughput (not the clock rate) of about 10 11 floating-point operations (FLOPs) per hour compared with the approximate 10 5 provided by the UNIVAC-1. The purpose of this discussion is to illustrate the computational complexity of modeling large (in wavelengths) electromagnetic problems. In particular the author makes the point that simply relying on faster computers for increasing the size and complexity of problems that can be modeled is less effective than might be anticipated from this raw increase in computer throughput. He suggests that rather than depending on faster computers alone, various analytical and numerical alternatives need development for reducing the overall FLOP count required to acquire the information desired. One approach is to decrease the operation count of the basic model computation itself, by reducing the order of the frequency dependence of the various numerical operations or their multiplying coefficients. Another is to decrease the number of model evaluations that are needed, an example being the number of frequency samples required to define a wideband response, by using an auxiliary model of the expected behavior. 11 refs., 5 figs., 2 tabs

  5. A trans-dimensional Bayesian Markov chain Monte Carlo algorithm for model assessment using frequency-domain electromagnetic data

    Science.gov (United States)

    Minsley, Burke J.

    2011-01-01

    A meaningful interpretation of geophysical measurements requires an assessment of the space of models that are consistent with the data, rather than just a single, ‘best’ model which does not convey information about parameter uncertainty. For this purpose, a trans-dimensional Bayesian Markov chain Monte Carlo (MCMC) algorithm is developed for assessing frequencydomain electromagnetic (FDEM) data acquired from airborne or ground-based systems. By sampling the distribution of models that are consistent with measured data and any prior knowledge, valuable inferences can be made about parameter values such as the likely depth to an interface, the distribution of possible resistivity values as a function of depth and non-unique relationships between parameters. The trans-dimensional aspect of the algorithm allows the number of layers to be a free parameter that is controlled by the data, where models with fewer layers are inherently favoured, which provides a natural measure of parsimony and a significant degree of flexibility in parametrization. The MCMC algorithm is used with synthetic examples to illustrate how the distribution of acceptable models is affected by the choice of prior information, the system geometry and configuration and the uncertainty in the measured system elevation. An airborne FDEM data set that was acquired for the purpose of hydrogeological characterization is also studied. The results compare favorably with traditional least-squares analysis, borehole resistivity and lithology logs from the site, and also provide new information about parameter uncertainty necessary for model assessment.

  6. Applied Electromagnetics

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, H; Marinova, I; Cingoski, V [eds.

    2002-07-01

    These proceedings contain papers relating to the 3rd Japanese-Bulgarian-Macedonian Joint Seminar on Applied Electromagnetics. Included are the following groups: Numerical Methods I; Electrical and Mechanical System Analysis and Simulations; Inverse Problems and Optimizations; Software Methodology; Numerical Methods II; Applied Electromagnetics.

  7. Applied Electromagnetics

    International Nuclear Information System (INIS)

    Yamashita, H.; Marinova, I.; Cingoski, V.

    2002-01-01

    These proceedings contain papers relating to the 3rd Japanese-Bulgarian-Macedonian Joint Seminar on Applied Electromagnetics. Included are the following groups: Numerical Methods I; Electrical and Mechanical System Analysis and Simulations; Inverse Problems and Optimizations; Software Methodology; Numerical Methods II; Applied Electromagnetics

  8. Electromagnetic compatibility methods, analysis, circuits, and measurement

    CERN Document Server

    Weston, David A

    2016-01-01

    Revised, updated, and expanded, Electromagnetic Compatibility: Methods, Analysis, Circuits, and Measurement, Third Edition provides comprehensive practical coverage of the design, problem solving, and testing of electromagnetic compatibility (EMC) in electrical and electronic equipment and systems. This new edition provides novel information on theory, applications, evaluations, electromagnetic computational programs, and prediction techniques available. With sixty-nine schematics providing examples for circuit level electromagnetic interference (EMI) hardening and cost effective EMI problem solving, this book also includes 1130 illustrations and tables. Including extensive data on components and their correct implementation, the myths, misapplication, misconceptions, and fallacies that are common when discussing EMC/EMI will also be addressed and corrected.

  9. Electromagnetic interactions

    International Nuclear Information System (INIS)

    Bosanac, Slobodan Danko

    2016-01-01

    This book is devoted to theoretical methods used in the extreme circumstances of very strong electromagnetic fields. The development of high power lasers, ultrafast processes, manipulation of electromagnetic fields and the use of very fast charged particles interacting with other charges requires an adequate theoretical description. Because of the very strong electromagnetic field, traditional theoretical approaches, which have primarily a perturbative character, have to be replaced by descriptions going beyond them. In the book an extension of the semi-classical radiation theory and classical dynamics for particles is performed to analyze single charged atoms and dipoles submitted to electromagnetic pulses. Special attention is given to the important problem of field reaction and controlling dynamics of charges by an electromagnetic field.

  10. Handbook of electromagnetic compatibility

    CERN Document Server

    1995-01-01

    This""know-how""book gives readers a concise understanding of the fundamentals of EMC, from basic mathematical and physical concepts through present, computer-age methods used in analysis, design, and tests. With contributions from leading experts in their fields, the text provides a comprehensive overview. Fortified with information on how to solve potential electromagnetic interference (EMI) problems that may arise in electronic design, practitioners will be betterable to grasp the latest techniques, trends, and applications of this increasingly important engineering discipline.Handbook of E

  11. Children and adults exposed to electromagnetic fields at the ICNIRP reference levels: theoretical assessment of the induced peak temperature increase

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, J F; Paulides, M M; Van Rhoon, G C [Erasmus MC-Daniel den Hoed Cancer Center, Department of Radiation Oncology, Section Hyperthermia, PO Box 5201, NL-3008 AE, Rotterdam (Netherlands); Neufeld, E; Christ, A; Kuster, N, E-mail: j.bakker@erasmusmc.nl [Foundation for Research on Information Technologies in Society (IT' IS) (Switzerland)

    2011-08-07

    To avoid potentially adverse health effects of electromagnetic fields (EMF), the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined EMF reference levels. Restrictions on induced whole-body-averaged specific absorption rate (SAR{sub wb}) are provided to keep the whole-body temperature increase (T{sub body,incr}) under 1 deg. C during 30 min. Additional restrictions on the peak 10 g spatial-averaged SAR (SAR{sub 10g}) are provided to prevent excessive localized tissue heating. The objective of this study is to assess the localized peak temperature increase (T{sub incr,max}) in children upon exposure at the reference levels. Finite-difference time-domain modeling was used to calculate T{sub incr,max} in six children and two adults exposed to orthogonal plane-wave configurations. We performed a sensitivity study and Monte Carlo analysis to assess the uncertainty of the results. Considering the uncertainties in the model parameters, we found that a peak temperature increase as high as 1 deg. C can occur for worst-case scenarios at the ICNIRP reference levels. Since the guidelines are deduced from temperature increase, we used T{sub incr,max} as being a better metric to prevent excessive localized tissue heating instead of localized peak SAR. However, we note that the exposure time should also be considered in future guidelines. Hence, we advise defining limits on T{sub incr,max} for specified durations of exposure.

  12. Assessment of electromagnetic fields intensity emitted by cellular phone base stations in surrounding flats - a preliminary study

    International Nuclear Information System (INIS)

    Zmyslony, M.; Politanski, P.; Mamrot, P.; Bortkiewicz, A.

    2006-01-01

    A rapid development of mobile telecommunications (MT) has resulted in an increased concern about possible detrimental health effects of electromagnetic fields (EMFs) emitted by MT systems, and by MT base stations in particular. Research into EMFs effects on the health of inhabitants living in their vicinity requires first of all a solid assessment of the exposure level. Up to now, the reports in this field have been rather scant. This article presents the results of preliminary measurements of EMFs fields in selected flats around selected base stations in the city of Lodz. Measurements of electric field strength, E, to assess EMF exposure were based on the standard procedures currently in force in Poland. As the study is regarded as a preliminary one, the measurements were conducted in buildings with the expected largest radiation. The measurements show that in the flats located up to 500 m from the base station, EMFs are within the limits specified by relevant Polish regulations on the general public and environmental protection. It was also observed that in a few (less than 10%) flats the field with E exceeded 0.8 V/m. The results show that there are no correlations between electric field strength and distance between the flat and the base station. Therefore, the distance from the base station cannot be used to represent the exposure rate; to determine the latter, EMF measurements are necessary. (author)

  13. Children and adults exposed to electromagnetic fields at the ICNIRP reference levels: theoretical assessment of the induced peak temperature increase.

    Science.gov (United States)

    Bakker, J F; Paulides, M M; Neufeld, E; Christ, A; Kuster, N; van Rhoon, G C

    2011-08-07

    To avoid potentially adverse health effects of electromagnetic fields (EMF), the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined EMF reference levels. Restrictions on induced whole-body-averaged specific absorption rate (SAR(wb)) are provided to keep the whole-body temperature increase (T(body, incr)) under 1 °C during 30 min. Additional restrictions on the peak 10 g spatial-averaged SAR (SAR(10g)) are provided to prevent excessive localized tissue heating. The objective of this study is to assess the localized peak temperature increase (T(incr, max)) in children upon exposure at the reference levels. Finite-difference time-domain modeling was used to calculate T(incr, max) in six children and two adults exposed to orthogonal plane-wave configurations. We performed a sensitivity study and Monte Carlo analysis to assess the uncertainty of the results. Considering the uncertainties in the model parameters, we found that a peak temperature increase as high as 1 °C can occur for worst-case scenarios at the ICNIRP reference levels. Since the guidelines are deduced from temperature increase, we used T(incr, max) as being a better metric to prevent excessive localized tissue heating instead of localized peak SAR. However, we note that the exposure time should also be considered in future guidelines. Hence, we advise defining limits on T(incr, max) for specified durations of exposure.

  14. Interference of mobile phones and digitally enhanced cordless telecommunications mobile phones in renal scintigraphy.

    Science.gov (United States)

    Stegmayr, Armin; Fessl, Benjamin; Hörtnagl, Richard; Marcadella, Michael; Perkhofer, Susanne

    2013-08-01

    The aim of the study was to assess the potential negative impact of cellular phones and digitally enhanced cordless telecommunication (DECT) devices on the quality of static and dynamic scintigraphy to avoid repeated testing in infant and teenage patients to protect them from unnecessary radiation exposure. The assessment was conducted by performing phantom measurements under real conditions. A functional renal-phantom acting as a pair of kidneys in dynamic scans was created. Data were collected using the setup of cellular phones and DECT phones placed in different positions in relation to a camera head to test the potential interference of cellular phones and DECT phones with the cameras. Cellular phones reproducibly interfered with the oldest type of gamma camera, which, because of its single-head specification, is the device most often used for renal examinations. Curves indicating the renal function were considerably disrupted; cellular phones as well as DECT phones showed a disturbance concerning static acquisition. Variable electromagnetic tolerance in different types of γ-cameras could be identified. Moreover, a straightforward, low-cost method of testing the susceptibility of equipment to interference caused by cellular phones and DECT phones was generated. Even though some departments use newer models of γ-cameras, which are less susceptible to electromagnetic interference, we recommend testing examination rooms to avoid any interference caused by cellular phones. The potential electromagnetic interference should be taken into account when the purchase of new sensitive medical equipment is being considered, not least because the technology of mobile communication is developing fast, which also means that different standards of wave bands will be issued in the future.

  15. Electromagnetic shield

    International Nuclear Information System (INIS)

    Miller, J.S.

    1987-01-01

    An electromagnetic shield is described comprising: closed, electrically-conductive rings, each having an open center; and binder means for arranging the rings in a predetermined, fixed relationship relative to each other, the so-arranged rings and binder means defining an outer surface; wherein electromagnetic energy received by the shield from a source adjacent its outer surface induces an electrical current to flow in a predetermined direction adjacent and parallel to the outer surface, through the rings; and wherein each ring is configured to cause source-induced alternating current flowing through the portion of the ring closest to the outer surface to electromagnetically induce an oppositely-directed current in the portion of the ring furthest from the surface, such oppositely-directed current bucking any source-induced current in the latter ring portion and thus reducing the magnitude of current flowing through it, whereby the electromagnetic shielding effected by the shield is enhanced

  16. Engineering electromagnetics

    CERN Document Server

    Thomas, David T; Hartnett, James P; Hughes, William F

    1973-01-01

    The applications involving electromagnetic fields are so pervasive that it is difficult to estimate their contribution to the industrial output: generation of electricity, power transmission lines, electric motors, actuators, relays, radio, TV and microwave transmission and reception, magnetic storage, and even the mundane little magnet used to hold a paper note on the refrigerator are all electromagnetic in nature. One would be hard pressed to find a device that works without relaying on any electromagnetic principle or effect. This text provides a good theoretical understanding of the electromagnetic field equations but also treats a large number of applications. In fact, no topic is presented unless it is directly applicable to engineering design or unless it is needed for the understanding of another topic. In electrostatics, for example, the text includes discussions of photocopying, ink-jet printing, electrostatic separation and deposition, sandpaper production, paint spraying, and powder coating. In ma...

  17. FDTD assessment of human exposure to electromagnetic fields from WiFi and bluetooth devices in some operating situations.

    Science.gov (United States)

    Martínez-Búrdalo, M; Martín, A; Sanchis, A; Villar, R

    2009-02-01

    In this work, the numerical dosimetry in human exposure to the electromagnetic fields from antennas of wireless devices, such as those of wireless local area networks (WLAN) access points or phone and computer peripherals with Bluetooth antennas, is analyzed with the objective of assessing guidelines compliance. Several geometrical configurations are considered to simulate possible exposure situations of a person to the fields from WLAN or Bluetooth antennas operating at 2400 MHz. The exposure to radiation from two sources of different frequencies when using a 1800 MHz GSM mobile phone connected via Bluetooth with a hands-free car kit is also considered. The finite-difference time-domain (FDTD) method is used to calculate electric and magnetic field values in the vicinity of the antennas and specific absorption rates (SAR) in a high-resolution model of the human head and torso, to be compared with the limits from the guidelines (reference levels and basic restrictions, respectively). Results show that the exposure levels in worst-case situations studied are lower than those obtained when analyzing the exposure to mobile phones, as could be expected because of the low power of the signals and the distance between the human and the antennas, with both field and SAR values being far below the limits established by the guidelines, even when considering the combined exposure to both a GSM and a Bluetooth antenna. Copyright 2008 Wiley-Liss, Inc.

  18. Assessment of induced SAR in children exposed to electromagnetic plane waves between 10 MHz and 5.6 GHz

    International Nuclear Information System (INIS)

    Bakker, J F; Paulides, M M; Van Rhoon, G C; Christ, A; Kuster, N

    2010-01-01

    To avoid potentially adverse health effects of electromagnetic fields (EMF), the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined EMF reference levels from the basic restrictions on the induced whole-body-averaged specific absorption rate (SAR wb ) and the peak 10 g spatial-averaged SAR (SAR 10g ). The objective of this study is to assess if the SAR in children remains below the basic restrictions upon exposure at the reference levels. Finite difference time domain (FDTD) modeling was used to calculate the SAR in six children and two adults when exposed to all 12 orthogonal plane wave configurations. A sensitivity study showed an expanded uncertainty of 53% (SAR wb ) and 58% (SAR 10g ) due to variations in simulation settings and tissue properties. In this study, we found that the basic restriction on the SAR wb is occasionally exceeded for children, up to a maximum of 45% in small children. The maximum SAR 10g values, usually found at body protrusions, remain under the limit for all scenarios studied. Our results are in good agreement with the literature, suggesting that the recommended ICNIRP reference levels may need fine tuning.

  19. Assessment of induced SAR in children exposed to electromagnetic plane waves between 10 MHz and 5.6 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Bakker, J F; Paulides, M M; Van Rhoon, G C [Erasmus MC-Daniel den Hoed Cancer Center, Department of Radiation Oncology, Section Hyperthermia, PO box 5201, NL-3008 AE, Rotterdam (Netherlands); Christ, A; Kuster, N, E-mail: j.bakker@erasmusmc.n [Foundation for Research on Information Technologies in Society (IT' IS) (Switzerland)

    2010-06-07

    To avoid potentially adverse health effects of electromagnetic fields (EMF), the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined EMF reference levels from the basic restrictions on the induced whole-body-averaged specific absorption rate (SAR{sub wb}) and the peak 10 g spatial-averaged SAR (SAR{sub 10g}). The objective of this study is to assess if the SAR in children remains below the basic restrictions upon exposure at the reference levels. Finite difference time domain (FDTD) modeling was used to calculate the SAR in six children and two adults when exposed to all 12 orthogonal plane wave configurations. A sensitivity study showed an expanded uncertainty of 53% (SAR{sub wb}) and 58% (SAR{sub 10g}) due to variations in simulation settings and tissue properties. In this study, we found that the basic restriction on the SAR{sub wb} is occasionally exceeded for children, up to a maximum of 45% in small children. The maximum SAR{sub 10g} values, usually found at body protrusions, remain under the limit for all scenarios studied. Our results are in good agreement with the literature, suggesting that the recommended ICNIRP reference levels may need fine tuning.

  20. Electromagnetic Landscape

    DEFF Research Database (Denmark)

    Cermak, Daniel; Okutsu, Ayaka; Jørgensen, Stina Marie Hasse

    2015-01-01

    Daniel Cermak-Sassenrath, Ayaka Okutsu, Stina Hasse. Electromagnetic Landscape - In-between Signal, Noise and Environment. Installation and artist talk. 21th International Symposium on Electronic Art (ISEA) 2015, Vancouver, CAN, Aug 14-18, 2015.......Daniel Cermak-Sassenrath, Ayaka Okutsu, Stina Hasse. Electromagnetic Landscape - In-between Signal, Noise and Environment. Installation and artist talk. 21th International Symposium on Electronic Art (ISEA) 2015, Vancouver, CAN, Aug 14-18, 2015....

  1. Determination of the duty cycle of WLAN for realistic radio frequency electromagnetic field exposure assessment.

    Science.gov (United States)

    Joseph, Wout; Pareit, Daan; Vermeeren, Günter; Naudts, Dries; Verloock, Leen; Martens, Luc; Moerman, Ingrid

    2013-01-01

    Wireless Local Area Networks (WLANs) are commonly deployed in various environments. The WLAN data packets are not transmitted continuously but often worst-case exposure of WLAN is assessed, assuming 100% activity and leading to huge overestimations. Actual duty cycles of WLAN are thus of importance for time-averaging of exposure when checking compliance with international guidelines on limiting adverse health effects. In this paper, duty cycles of WLAN using Wi-Fi technology are determined for exposure assessment on large scale at 179 locations for different environments and activities (file transfer, video streaming, audio, surfing on the internet, etc.). The median duty cycle equals 1.4% and the 95th percentile is 10.4% (standard deviation SD = 6.4%). Largest duty cycles are observed in urban and industrial environments. For actual applications, the theoretical upper limit for the WLAN duty cycle is 69.8% and 94.7% for maximum and minimum physical data rate, respectively. For lower data rates, higher duty cycles will occur. Although counterintuitive at first sight, poor WLAN connections result in higher possible exposures. File transfer at maximum data rate results in median duty cycles of 47.6% (SD = 16%), while it results in median values of 91.5% (SD = 18%) at minimum data rate. Surfing and audio streaming are less intensively using the wireless medium and therefore have median duty cycles lower than 3.2% (SD = 0.5-7.5%). For a specific example, overestimations up to a factor 8 for electric fields occur, when considering 100% activity compared to realistic duty cycles. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. At the heart of the waves - Electromagnetic fields in question

    International Nuclear Information System (INIS)

    Ndagijimana, Fabien; Gaudaire, Francois

    2013-01-01

    This document briefly presents a book in which the author describes what an electromagnetic wave is, the use of electromagnetic waves, how an information is transmitted by means of an electromagnetic wave, what wave modulation is, what multiplexing is, what the characteristics of an antenna are, how waves propagate, how electromagnetic shielding works, what the CEM (electromagnetic compatibility) is, and how a cellular phone network works, in the framework of electromagnetic fields risk assessment

  3. Multiple electromagnetic excitations of relativistic projectiles

    International Nuclear Information System (INIS)

    Llope, W.J.; Braun-Munzinger, P.

    1992-01-01

    Conditions optimum for the first experimental verification of the multiplication electromagnetic excitations of nuclei in relativistic nucleus-nucleus collisions are described. The relative magnitudes of three important physical processes that might interfere with such a measurement are compared to the predicted strengths for the single and multiple electromagnetic excitations for various choices of the projectile mass and beam energy. Strategies are presented for making inferences concerning the presence of multiple excitation strength in experimental data

  4. Assessment of exposure to radio frequency electromagnetic fields from smart utility meters in GB; part II) numerical assessment of induced SAR within the human body.

    Science.gov (United States)

    Qureshi, Muhammad R A; Alfadhl, Yasir; Chen, Xiaodong; Peyman, Azadeh; Maslanyj, Myron; Mann, Simon

    2018-04-01

    Human body exposure to radiofrequency electromagnetic waves emitted from smart meters was assessed using various exposure configurations. Specific energy absorption rate distributions were determined using three anatomically realistic human models. Each model was assigned with age- and frequency-dependent dielectric properties representing a collection of age groups. Generalized exposure conditions involving standing and sleeping postures were assessed for a home area network operating at 868 and 2,450 MHz. The smart meter antenna was fed with 1 W power input which is an overestimation of what real devices typically emit (15 mW max limit). The highest observed whole body specific energy absorption rate value was 1.87 mW kg -1 , within the child model at a distance of 15 cm from a 2,450 MHz device. The higher values were attributed to differences in dimension and dielectric properties within the model. Specific absorption rate (SAR) values were also estimated based on power density levels derived from electric field strength measurements made at various distances from smart meter devices. All the calculated SAR values were found to be very small in comparison to International Commission on Non-Ionizing Radiation Protection limits for public exposure. Bioelectromagnetics. 39:200-216, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Assessment of colorectal length using the electromagnetic capsule tracking system: a comparative validation study in healthy subjects.

    Science.gov (United States)

    Mark, E B; Poulsen, J L; Haase, A M; Frøkjaer, J B; Schlageter, V; Scott, S M; Krogh, K; Drewes, A M

    2017-09-01

    We aimed to determine colorectal length with the 3D-Transit system by describing a 'centreline' of capsule movement and comparing it with known anatomy, as determined by magnetic resonance imaging (MRI). Further, we aimed to test the day-to-day variation of colorectal length assessed with the system. The 3D-Transit system consists of electromagnetic capsules that can be tracked as they traverse the gastrointestinal tract. Twenty-five healthy subjects were examined with both 3D-Transit and MRI. Another 21 healthy subjects were examined with 3D-Transit on two consecutive days. Computation of colorectal length from capsule passage was possible for 60 of the 67 3D-Transit recordings. The length of the colorectum measured with MRI and 3D-Transit was 95 (75-153) cm and 99 (77-147) cm, respectively (P = 0.15). The coefficient of variation (CV) between MRI and 3D-Transit was 7.8%. Apart from the caecum/ascending colon being 26% (P = 0.002) shorter on MRI, there were no other differences in total or segmental colorectal lengths between methods (all P > 0.05). The length of the colorectum measured with 3D-Transit on two consecutive days was 102 (73-119) cm and 103 (75-123) cm (P = 0.67). The CV between days was 7.3%. The 3D-Transit system allows accurate and reliable determination of colorectal length compared with MRI-derived colorectal length and between days. Antegrade or retrograde capsule movement relative to this centreline, as well as the length and speed of movements, may be determined by future studies to allow better classification and treatment in patients with dysmotility. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  6. Electromagnetic pump

    International Nuclear Information System (INIS)

    Ito, Koji; Suetake, Norio; Aizawa, Toshie; Nakasaki, Masayoshi

    1998-01-01

    The present invention provides an electromagnetic pump suitable to a recycling pump for liquid sodium as coolants of an FBR type reactor. Namely, a stator module of the electromagnetic pump of the present invention comprises a plurality of outer laminate iron core units and outer stator modules stacked alternately in the axial direction. With such a constitution, even a long electromagnetic pump having a large number of outer stator coils can be manufactured without damaging electric insulation of the outer stator coils. In addition, the inner circumferential surface of the outer laminate iron cores is urged and brought into contact with the outer circumferential surface of the outer duct by an elastic material. With such a constitution, Joule loss heat generated in the outer stator coils and internal heat generated in the outer laminate iron cores can be released to an electroconductive fluid flowing the inner circumference of the outer duct by way of the outer duct. (I.S.)

  7. Pregnancy and electromagnetic fields

    International Nuclear Information System (INIS)

    Bisseriex, Ch.; Laurent, P.; Cabaret, Ph.; Bonnet, C.; Marteau, E.; Le Berre, G.; Tirlemont, S.; Castro, H.; Becker, A.; Demaret, Ph.; Donati, M.; Ganem, Y.; Moureaux, P.

    2011-07-01

    This document briefly indicates the status of knowledge regarding the effect of magnetic fields on biological tissues and pregnancy, outlines the lack of data on some frequencies and the weakness of studies on long term effects on child development. It evokes the issue of exposure assessment and that of identification of workstations exposed to electromagnetic fields

  8. Ultrasonic Phased Array Assessment of the Interference Fit and Leak Path of the North Anna Unit 2 Control Rod Drive Mechanism Nozzle 63 with Destructive Validation

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, Susan L.; Cinson, Anthony D.; MacFarlan, Paul J.; Hanson, Brady D.; Mathews, Royce

    2012-08-01

    The objective of this investigation was to evaluate the efficacy of ultrasonic testing (UT) for primary water leak path assessments of reactor pressure vessel (RPV) upper head penetrations. Operating reactors have experienced leakage when stress corrosion cracking of nickel-based alloy penetrations allowed primary water into the annulus of the interference fit between the penetration and the low-alloy steel RPV head. In this investigation, UT leak path data were acquired for an Alloy 600 control rod drive mechanism nozzle penetration, referred to as Nozzle 63, which was removed from the North Anna Unit 2 reactor when the RPV head was replaced in 2002. In-service inspection prior to the head replacement indicated that Nozzle 63 had a probable leakage path through the interference fit region. Nozzle 63 was examined using a phased-array UT probe with a 5.0-MHz, eight-element annular array. Immersion data were acquired from the nozzle inner diameter surface. The UT data were interpreted by comparing to responses measured on a mockup penetration with known features. Following acquisition of the UT data, Nozzle 63 was destructively examined to determine if the features identified in the UT examination, including leakage paths and crystalline boric acid deposits, could be visually confirmed. Additional measurements of boric acid deposit thickness and low-alloy steel wastage were made to assess how these factors affect the UT response. The implications of these findings for interpreting UT leak path data are described.

  9. Electromagnetic Wave Propagation Assessment

    Science.gov (United States)

    1993-03-01

    the increacd availabilit , ol such systems are critical for their optimum use. This computers and display technology. An early example is illustrated...Gaseous zO - H 0.25 mm/hr 2 H2 I - Temperature - 20 C D ~~Sea Level - p1 am, Z Water Vapour - 7.5 g/m 3 I- < 0 3Gaseous L . II I I I LIiIU hJ1 001 10

  10. Electromagnetic Landscape

    DEFF Research Database (Denmark)

    Cermak, Daniel; Okutsu, Ayaka; Hasse, Stina

    2015-01-01

    Electromagnetic Landscape demonstrates in direct, tangible and immediate ways effects of the disruption of the familiar. An ubiquitous technological medium, FM radio, is turned into an alien and unfamiliar one. Audience participation, the environment, radio signals and noise create a site...

  11. Children and adults exposed to electromagnetic fields at the ICNIRP reference levels: Theoretical assessment of the induced peak temperature increase

    NARCIS (Netherlands)

    J. Bakker (Jan); M.M. Paulides (Maarten); E. Neufeld; A. Christ (A.); N. Kuster (Niels); G.C. van Rhoon (Gerard)

    2011-01-01

    textabstractTo avoid potentially adverse health effects of electromagnetic fields (EMF), the International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined EMF reference levels. Restrictions on induced whole-body-averaged specific absorption rate (SAR wb) are provided to keep the

  12. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2014-09-01

    Full Text Available Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students, blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2 while the phone was ringing. For Control- Repeat group (15 students, two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (ΔC in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test. To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors.

  13. Electromagnetic Reciprocity.

    Energy Technology Data Exchange (ETDEWEB)

    Aldridge, David F.

    2014-11-01

    A reciprocity theorem is an explicit mathematical relationship between two different wavefields that can exist within the same space - time configuration. Reciprocity theorems provi de the theoretical underpinning for mod ern full waveform inversion solutions, and also suggest practical strategies for speed ing up large - scale numerical modeling of geophysical datasets . In the present work, several previously - developed electromagnetic r eciprocity theorems are generalized to accommodate a broader range of medi um, source , and receiver types. Reciprocity relations enabling the interchange of various types of point sources and point receivers within a three - dimensional electromagnetic model are derived. Two numerical modeling algorithms in current use are successfully tested for adherence to reciprocity. Finally, the reciprocity theorem forms the point of departure for a lengthy derivation of electromagnetic Frechet derivatives. These mathe matical objects quantify the sensitivity of geophysical electromagnetic data to variatio ns in medium parameters, and thus constitute indispensable tools for solution of the full waveform inverse problem. ACKNOWLEDGEMENTS Sandia National Labor atories is a multi - program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the US Department of Energy's National Nuclear Security Administration under contract DE - AC04 - 94AL85000. Signif icant portions of the work reported herein were conducted under a Cooperative Research and Development Agreement (CRADA) between Sandia National Laboratories (SNL) and CARBO Ceramics Incorporated. The author acknowledges Mr. Chad Cannan and Mr. Terry Pa lisch of CARBO Ceramics, and Ms. Amy Halloran, manager of SNL's Geophysics and Atmospheric Sciences Department, for their interest in and encouragement of this work. Special thanks are due to Dr . Lewis C. Bartel ( recently retired from Sandia National Labo ratories

  14. IETS and quantum interference

    DEFF Research Database (Denmark)

    Jørgensen, Jacob Lykkebo; Gagliardi, Alessio; Pecchia, Alessandro

    2014-01-01

    Destructive quantum interference in single molecule electronics is an intriguing phenomenon; however, distinguishing quantum interference effects from generically low transmission is not trivial. In this paper, we discuss how quantum interference effects in the transmission lead to either low...... suppressed when quantum interference effects dominate. That is, we expand the understanding of propensity rules in inelastic electron tunneling spectroscopy to molecules with destructive quantum interference....

  15. Quantum interference in plasmonic circuits.

    Science.gov (United States)

    Heeres, Reinier W; Kouwenhoven, Leo P; Zwiller, Valery

    2013-10-01

    Surface plasmon polaritons (plasmons) are a combination of light and a collective oscillation of the free electron plasma at metal/dielectric interfaces. This interaction allows subwavelength confinement of light beyond the diffraction limit inherent to dielectric structures. As a result, the intensity of the electromagnetic field is enhanced, with the possibility to increase the strength of the optical interactions between waveguides, light sources and detectors. Plasmons maintain non-classical photon statistics and preserve entanglement upon transmission through thin, patterned metallic films or weakly confining waveguides. For quantum applications, it is essential that plasmons behave as indistinguishable quantum particles. Here we report on a quantum interference experiment in a nanoscale plasmonic circuit consisting of an on-chip plasmon beamsplitter with integrated superconducting single-photon detectors to allow efficient single plasmon detection. We demonstrate a quantum-mechanical interaction between pairs of indistinguishable surface plasmons by observing Hong-Ou-Mandel (HOM) interference, a hallmark non-classical interference effect that is the basis of linear optics-based quantum computation. Our work shows that it is feasible to shrink quantum optical experiments to the nanoscale and offers a promising route towards subwavelength quantum optical networks.

  16. Engineering electromagnetics

    CERN Document Server

    Ida, Nathan

    2015-01-01

    This book provides students with a thorough theoretical understanding of electromagnetic field equations and it also treats a large number of applications. The text is a comprehensive two-semester textbook. The work treats most topics in two steps – a short, introductory chapter followed by a second chapter with in-depth extensive treatment; between 10 to 30 applications per topic; examples and exercises throughout the book; experiments, problems  and summaries.   The new edition includes: updated end of chapter problems; a new introduction to electromagnetics based on behavior of charges; a new section on units; MATLAB tools for solution of problems and demonstration of subjects; most chapters include a summary. The book is an undergraduate textbook at the Junior level, intended for required classes in electromagnetics. It is written in simple terms with all details of derivations included and all steps in solutions listed. It requires little beyond basic calculus and can be used for self-study. The weal...

  17. Assessment of recovery and recrystallisation behaviours of cold rolled IF steel through non-destructive electromagnetic characterisation

    Science.gov (United States)

    Roy, Rajat K.; Dutta, Siuli; Panda, Ashis K.; Rajinikanth, V.; Das, Swapan K.; Mitra, Amitava; Strangwood, M.; Davis, Claire L.

    2018-07-01

    The recovery and recrystallisation behaviours of cold rolled IF steel have been investigated by destructive (optical microscopy and hardness) and non-destructive electromagnetic sensor, (which allows direct measurement of strip samples with no surface preparation) techniques. The onset and completion of recrystallisation are clearly monitored through destructive techniques of optical microscopy and hardness measurements. The nucleation of new recrystallised grains is observed in the sample annealed at 600 °C/15 min, while completion of recrystallisation takes place at 700 °C/15 min. The destructive techniques are not very accurate in monitoring recovery, for example, changes in hardness of accounting for ≈60% change in the coercivity value. Therefore, the measurement of magnetic softening through an electromagnetic sensor acts a crucial role for understanding recovery and recrystallisation behaviours of steels during industrial processing. The present investigation is aimed not only for controlling product quality but also saving characterisation time through off line monitoring during steel processing at industry.

  18. Electromagnetically induced absorption via incoherent collisions

    International Nuclear Information System (INIS)

    Yang Xihua; Sheng Jiteng; Xiao Min

    2011-01-01

    We conduct theoretical studies on electromagnetically induced absorption via incoherent collisions in an inhomogeneously broadened ladder-type three-level system with the density-matrix approach. The effects of the collision-induced coherence decay rates as well as the probe laser field intensity on the probe field absorption are examined. It is shown that with the increase of the collisional decay rates in a moderate range, a narrow dip due to electromagnetically induced transparency superimposed on the Doppler-broadened absorption background can be turned into a narrow peak under the conditions that the probe field intensity is not very weak as compared to the pump field, which results from the enhancement of constructive interference and suppression of destructive interference between one-photon and multiphoton transition pathways. The physical origin of the collision-assisted electromagnetically induced absorption is analyzed with a power-series solution of the density-matrix equations.

  19. An overview of electromagnetic compatibility (EMC)

    International Nuclear Information System (INIS)

    Raffi, M.; Qadeer, S.; Anwar, M.

    1998-01-01

    The world is becoming increasingly dependent upon the use of electrical and electronic equipment. In the recent years, introduction of semiconductor based devices, microprocessor and micro computer have brought about a technological revolution that has had far reaching effects in the home, in industry, in commerce and in defense. Electromagnetic Compatibility (EMC) is the discipline which attempts to over come or, at least, minimize the effects of mismatch between equipment and the operating environment in accordance with agreed specifications, standards and regulations. Increased electromagnetic pollution in the environment has caused tremendous concern in the electronic industry and among users. Designers of the electronic products and systems want to be sure that their products do not emit excessive, unintentional radiation to interfere with the operation of the other systems, nor should these products be susceptible to electromagnetic interference which may degrade their performance. (author)

  20. Narrow field electromagnetic sensor system and method

    International Nuclear Information System (INIS)

    McEwan, T.E.

    1996-01-01

    A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments. 12 figs

  1. The reliability assessment of the electromagnetic valve of high-speed electric multiple units braking system based on two-parameter exponential distribution

    Directory of Open Access Journals (Sweden)

    Jianwei Yang

    2016-06-01

    Full Text Available In order to solve the reliability assessment of braking system component of high-speed electric multiple units, this article, based on two-parameter exponential distribution, provides the maximum likelihood estimation and Bayes estimation under a type-I life test. First of all, we evaluate the failure probability value according to the classical estimation method and then obtain the maximum likelihood estimation of parameters of two-parameter exponential distribution by performing and using the modified likelihood function. On the other hand, based on Bayesian theory, this article also selects the beta and gamma distributions as the prior distribution, combines with the modified maximum likelihood function, and innovatively applies a Markov chain Monte Carlo algorithm to parameters assessment based on Bayes estimation method for two-parameter exponential distribution, so that two reliability mathematical models of the electromagnetic valve are obtained. Finally, through type-I life test, the failure rates according to maximum likelihood estimation and Bayes estimation method based on Markov chain Monte Carlo algorithm are, respectively, 2.650 × 10−5 and 3.037 × 10−5. Compared with the failure rate of a electromagnetic valve 3.005 × 10−5, it proves that the Bayes method can use a Markov chain Monte Carlo algorithm to estimate reliability for two-parameter exponential distribution and Bayes estimation is more closer to the value of electromagnetic valve. So, by fully integrating multi-source, Bayes estimation method can preferably modify and precisely estimate the parameters, which can provide a certain theoretical basis for the safety operation of high-speed electric multiple units.

  2. Polímeros condutores intrínsecos e seu potencial em blindagem de radiações eletromagnéticas Intrinsically conducting polymers and their potencial in electromagnetic interference shielding

    Directory of Open Access Journals (Sweden)

    Roselena Faez

    2000-09-01

    Full Text Available A procura por novos materiais que possuam propriedades magnéticas e dielétricas adequadas ao uso em absorvedores de radiação eletromagnética é de grande importância. Dentre os materiais em estudo, os polímeros condutores têm sido aplicados como centros de absorção de radiação, devido à possibilidade de variação da sua condutividade com a freqüência da radiação das ondas incidentes, sendo esta pesquisa o estado da arte no processamento de materiais absorvedores de radiação (MAR. O objetivo deste trabalho é apresentar a ampla faixa de propriedades dos polímeros condutores, correlacionando-as com o potencial de aplicação destes materiais como aditivos no processamento de MAR. Uma breve análise dos resultados obtidos com uma blenda de EPDM contendo 30-80 %(m/m de PAni-DBSA e espessuras de 1 e 3 mm, analisadas na faixa de 8-12 GHz, mostra que o material absorveu na faixa de 50 a 90% da radiação incidente.The search for new materials possessing magnetic and dieletric properties adequated to be used as radar absorbing materials has been of great importance. Among the materials under study, conducting polymers have been applied due to the possibility of variation of their conductivity with the frequency of the incident radiation. These research areas have been considered the state of the art in the processing of radar absorbing materials. The aim of this work is to present the large range of properties of the conducting polymers and their correlation with the potential application of these materials as electromagnetic radiation absorbers. Some results are also presented on blends of EPDM and 30-80% (w/w of PAni-DBSA with thickness of 1 and 3 mm, analysed in the range of 8-12 GHz, which absorbed in the range of 50-90% of incident radiation.

  3. Histories electromagnetism

    International Nuclear Information System (INIS)

    Burch, Aidan

    2004-01-01

    Working within the HPO (History Projection Operator) Consistent Histories formalism, we follow the work of Savvidou on (scalar) field theory [J. Math. Phys. 43, 3053 (2002)] and that of Savvidou and Anastopoulos on (first-class) constrained systems [Class. Quantum Gravt. 17, 2463 (2000)] to write a histories theory (both classical and quantum) of Electromagnetism. We focus particularly on the foliation-dependence of the histories phase space/Hilbert space and the action thereon of the two Poincare groups that arise in histories field theory. We quantize in the spirit of the Dirac scheme for constrained systems

  4. Time domain electromagnetic metal detectors

    International Nuclear Information System (INIS)

    Hoekstra, P.

    1996-01-01

    This presentation focuses on illustrating by case histories the range of applications and limitations of time domain electromagnetic (TDEM) systems for buried metal detection. Advantages claimed for TDEM metal detectors are: independent of instrument response (Geonics EM61) to surrounding soil and rock type; simple anomaly shape; mitigation of interference by ambient electromagnetic noise; and responsive to both ferrous and non-ferrous metallic targets. The data in all case histories to be presented were acquired with the Geonics EM61 TDEM system. Case histories are a test bed site on Molokai, Hawaii; Fort Monroe, Virginia; and USDOE, Rocky Flats Plant. The present limitations of this technology are: discrimination capabilities in terms of type of ordnance, and depth of burial is limited, and ability of resolving targets with small metallic ambient needs to be improved

  5. Benign Effect of Extremely Low-Frequency Electromagnetic Field on Brain Plasticity Assessed by Nitric Oxide Metabolism during Poststroke Rehabilitation

    Directory of Open Access Journals (Sweden)

    Natalia Cichoń

    2017-01-01

    Full Text Available Nitric oxide (NO is one of the most important signal molecules, involved in both physiological and pathological processes. As a neurotransmitter in the central nervous system, NO regulates cerebral blood flow, neurogenesis, and synaptic plasticity. The aim of our study was to investigate the effect of the extremely low-frequency electromagnetic field (ELF-EMF on generation and metabolism of NO, as a neurotransmitter, in the rehabilitation of poststroke patients. Forty-eight patients were divided into two groups: ELF-EMF and non-ELF-EMF. Both groups underwent the same 4-week rehabilitation program. Additionally, the ELF-EMF group was exposed to an extremely low-frequency electromagnetic field of 40 Hz, 7 mT, for 15 min/day. Levels of 3-nitrotyrosine, nitrate/nitrite, and TNFα in plasma samples were measured, and NOS2 expression was determined in whole blood samples. Functional status was evaluated before and after a series of treatments, using the Activity Daily Living, Geriatric Depression Scale, and Mini-Mental State Examination. We observed that application of ELF-EMF significantly increased 3-nitrotyrosine and nitrate/nitrite levels, while expression of NOS2 was insignificantly decreased in both groups. The results also show that ELF-EMF treatments improved functional and mental status. We conclude that ELF-EMF therapy is capable of promoting recovery in poststroke patients.

  6. Preoperative assessment of trigeminal neuralgia and hemifacial spasm using constructive interference in steady state-three-dimensional fourier transformation magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Iwao; Kobayashi, Eiichi; Hirai, Shinji; Yamaura, Akira [Chiba Univ. (Japan). School of Medicine

    2000-11-01

    Results of microvascular decompression (MVD) for trigeminal neuralgia (TN) and hemifacial spasm (HFS) may be improved by accurate preoperative assessment of neurovascular relationships at the root entry/exit zone (REZ). Constructive interference in steady state (CISS)-three-dimensional Fourier transformation (3DFT) magnetic resonance (MR) imaging was evaluated for visualizing the neurovascular relationships at the REZ. Fourteen patients with TN and eight patients with HFS underwent MR imaging using CISS-3DFT and 3D fast inflow with steady-state precession (FISP) sequences. Axial images of the cerebellopontine angle (CPA) obtained by the two sequences were reviewed to assess the neurovascular relationships at the REZ of the trigeminal and facial nerves. Eleven patients subsequently underwent MVD. Preoperative MR imaging findings were related to surgical observations and results. CISS MR imaging provided excellent contrast between the cranial nerves, small vessels, and cerebrospinal fluid (CSF) in the CPA. CISS was significantly better than FISP for delineating anatomic detail in the CPA (trigeminal and facial nerves, petrosal vein) and abnormal neurovascular relationships responsible for TN and HFS (vascular contact and deformity at the REZ). Preoperative CISS MR imaging demonstrated precisely the neurovascular relationships at the REZ and identified the offending artery in all seven patients with TN undergoing MVD. CISS MR imaging has high resolution and excellent contrast between cranial nerves, small vessels, and CSF, so can precisely and accurately delineate normal and abnormal neurovascular relationships at the REZ in the CPA, and is a valuable preoperative examination for MVD. (author)

  7. Preoperative assessment of trigeminal neuralgia and hemifacial spasm using constructive interference in steady state-three-dimensional fourier transformation magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yamakami, Iwao; Kobayashi, Eiichi; Hirai, Shinji; Yamaura, Akira

    2000-01-01

    Results of microvascular decompression (MVD) for trigeminal neuralgia (TN) and hemifacial spasm (HFS) may be improved by accurate preoperative assessment of neurovascular relationships at the root entry/exit zone (REZ). Constructive interference in steady state (CISS)-three-dimensional Fourier transformation (3DFT) magnetic resonance (MR) imaging was evaluated for visualizing the neurovascular relationships at the REZ. Fourteen patients with TN and eight patients with HFS underwent MR imaging using CISS-3DFT and 3D fast inflow with steady-state precession (FISP) sequences. Axial images of the cerebellopontine angle (CPA) obtained by the two sequences were reviewed to assess the neurovascular relationships at the REZ of the trigeminal and facial nerves. Eleven patients subsequently underwent MVD. Preoperative MR imaging findings were related to surgical observations and results. CISS MR imaging provided excellent contrast between the cranial nerves, small vessels, and cerebrospinal fluid (CSF) in the CPA. CISS was significantly better than FISP for delineating anatomic detail in the CPA (trigeminal and facial nerves, petrosal vein) and abnormal neurovascular relationships responsible for TN and HFS (vascular contact and deformity at the REZ). Preoperative CISS MR imaging demonstrated precisely the neurovascular relationships at the REZ and identified the offending artery in all seven patients with TN undergoing MVD. CISS MR imaging has high resolution and excellent contrast between cranial nerves, small vessels, and CSF, so can precisely and accurately delineate normal and abnormal neurovascular relationships at the REZ in the CPA, and is a valuable preoperative examination for MVD. (author)

  8. A broadband electromagnetic UT system

    International Nuclear Information System (INIS)

    Repplinger, W.; Salzburger, H.J.

    1985-01-01

    An ultrasonic testing system based on contactless electromagnetic acoustic (E.M.A.) transduction has been developed by which broadband ultrasonic pulses are excited. This system overcomes disadvantages of usual E.M.A. transducers with meanderlike coil configuration, namely the excitation of narrowband pulses and the symmetrical radiation pattern. By dividing up a meanderlike coil into single elements and a time-delayed firing of the elements, whereby the time delay is given by the distance of the elements and the phase velocity of the wave propagating along the surface, the ultrasonic pulse radiated in one preferred direction becomes broadband by constructive interference. The signals radiated in the opposite direction do no more interfere. Its amplitude is smaller than that of the other direction, so that the transducer becomes uni-directional. This technique can be applied for the excitation of all dispersionless waves (bulk waves and guided waves)

  9. In vivo assessment of the ability of condensed tannins to interfere with the digestibility of plant protein in sheep

    Energy Technology Data Exchange (ETDEWEB)

    Andrabi, S.M.; Ritchie, M.M.; Stimson, C.; Horadagoda, A.; Hyde, M.; McNeill, D.M. [MC Franklin Laboratory, Faculty of Veterinary Science, University of Sydney, Camden, NSW (Australia)]. E-mail: karalue@bigpond.net.au

    2005-08-19

    To assess the effect of condensed tannin (CT) astringency on the digestibility of protein post-ruminally, CT were purified from four types (accessions) of Mulga (Acacia aneura), and a Leucaena pallida and dosed into sheep as complexes with {sup 15}N-plant protein (tannin-protein complexes, TPC), together with an indigestible marker, chromium-EDTA (Cr-EDTA). Each CT treatment dose comprised 12 mg CT, 10 mg {sup 15}N-protein, and 2.77 mg of Cr. A protein-only control (same as the other TPC solutions but without any CT) treatment was also included to make a total of six treatments. Treatments were applied in two 6 x 6 Latin Square designs with 72 h between each infusion for each sheep. In the first, the solutions were infused post-ruminally via an abomasal cannula. In the second they were dosed directly into the mouth following an intra-nasal dose of an analogue of vasopressin in an attempt to stimulate the oesophageal groove reflex to direct the solutions more efficiently toward the small intestine. Results showed no detectable effect of CT type on the in vivo digestibility of the {sup 15}N-protein. Protein digestibilities were uniformly high, indicative of complete dissociation of the TPC. There was no correlation between protein digestibility, mouth to faeces, and protein digestibility, abomasum to faeces (P > 0.05). In vivo digestibility was also uncorrelated with CT astringencies defined in vitro (P > 0.05). Astringency in vitro was defined as the mg of CT required to achieve half-maximal precipitation of 0.5 mg of protein (bovine serum albumin). In vitro, the most astringent CT (A. aneura 883558), had at least 1.6 times the astringency of the weakest CT (A. aneura 842394). The A. aneura with the weakest CT also contained less than 1/3 the total amount of CT/g leaf dry matter than that with the strongest, highlighting the scope for selection of more nutritionally useful types of A. aneura. Limitations of the in vivo protocol used are discussed and it is concluded

  10. WEED INTERFERENCE IN EGGPLANT CROPS

    Directory of Open Access Journals (Sweden)

    LUIZ JUNIOR PEREIRA MARQUES

    2017-01-01

    Full Text Available Uncontrolled weed growth interferes with the growth eggplants and crop yields. To control weeds, the main weed species must be identified in crop growing areas and during weed control periods, as weed species might vary in relation to management practices. Therefore, this study aimed to identify the main weed species and determine the periods of weed interference in the eggplant cultivar Nápoli when grown under certain cultural practices, including plant staking and sprout thinning. The experiment was carried out in 2014 using a randomized complete block design, with 3 replications. The treatments consisted of 11 periods of (1 increasing weed control and (2 increasing coexistence of eggplant with weeds from the first day of transplanting (0-14, 0-28, 0-42, 0-56, 0-70, 0-84, 0-98, 0-112, 0-126, 0-140, and up do day 154. Eggplant staking and sprout thinning were performed 42 days after transplanting (DAT. Weed identification and crop yield assessments were performed to determine the Period Before Interference (PBI, Total Period of Interference Prevention (TPIP, and the Critical Period of Interference Prevention (CPIP. The major weeds found in the eggplant cultivar Nápoli were Eleusine indica, Portulaca oleracea, and Cyperus rotundus. Coexistence between the weed community and the eggplant throughout the entire crop production cycle reduced eggplant fruit yield by 78%. The PBI was 29 DAT and the TPIP was 48 DAT, resulting in 19 days of CPIP.

  11. Electromagnetic fields, pacemakers and defibrillators; Champs electromagnetiques, cardiostimulateurs et defibrillateurs

    Energy Technology Data Exchange (ETDEWEB)

    Guiguet, J.C. [Agence Nationale des Frequences (ANFR), 94 - Maisons Alfort (France); Dodinot, B.; Sadoul, N.; Blangy, H. [Centre Hospitalier Universitaire Nancy-Brabois, Clinique Cardiologique, 54 - Vandoeuvre Brabois (France); Nadi, M.; Hedjiedj, A.; Schmitt, P. [Universite Henri Poincare-Nancy, Lab. d' Instrumentation Electronique de Nancy, Faculte des Sciences, 54 - Vandoeuvre les Nancy (France); Joly, L.; Dodinot, B.; Aliot, E. [Centre Hospitalier Universitaire Nancy-Brabois, Service de Cardiologie, 54 - Vandoeuvre-les-Nancy (France); Silny, J. [Aachen University (Germany); Franck, R.; Himbert, C.; Hidden-Lucet, F.; Petitot, J.C.; Fontaine, G. [Hopital Pitie-Salpetriere, Institut de Cardiologie, Service de Rythmologie, 75 - Paris (France); Souques, M.; Lambrozo, J. [Electricite de France (EDF-Gaz de France), Service des Etudes Medicales, 75 - Paris (France); Magne, I.; Bailly, J.M. [Electricite de France (EDF-Gaz de France), Div. Recherche Developpement, 77 - Moret sur Loing (France); Trigano, J.A. [Centre Hospitalier Universitaire, Hopital Nord, 13 - Marseille (France); Burais, N. [CEGELY, Ecole Centrale de Lyon, 69 - Ecully (France); Gaspard, J.Y. [Magtech, 69 - Ecully (France); Andrivet, Ph. [Societe Medtronic France, 92 - Boulogne-Billancourt (France)

    2004-07-01

    Presentation of electromagnetic sources constituted by various radio transmitters contributing to different radio communication services in the environment. Results of a measures campaign to assess the electromagnetic field in the close neighbourhood of various stations. Analysis by frequency domains. (author)

  12. Electromagnetically shielded building

    International Nuclear Information System (INIS)

    Takahashi, T.; Nakamura, M.; Yabana, Y.; Ishikawa, T.; Nagata, K.

    1992-01-01

    This invention relates to a building having an electromagnetic shield structure well-suited for application to an information network system utilizing electromagnetic waves, and more particularly to an electromagnetically shielded building for enhancing the electromagnetic shielding performance of an external wall. 6 figs

  13. Electromagnetically shielded building

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, T; Nakamura, M; Yabana, Y; Ishikawa, T; Nagata, K

    1992-04-21

    This invention relates to a building having an electromagnetic shield structure well-suited for application to an information network system utilizing electromagnetic waves, and more particularly to an electromagnetically shielded building for enhancing the electromagnetic shielding performance of an external wall. 6 figs.

  14. Electromagnetic launchers

    Science.gov (United States)

    Kolm, H.; Mongeau, P.; Williams, F.

    1980-09-01

    Recent advances in energy storage, switching and magnet technology make electromagnetic acceleration a viable alternative to chemical propulsion for certain tasks, and a means to perform other tasks not previously feasible. Applications include the acceleration of gram-size particles for hypervelocity research and the initiation of fusion by impact, a replacement for chemically propelled artillery, the transportation of cargo and personnel over inaccessible terrain, and the launching of space vehicles to supply massive space operations, and for the disposal of nuclear waste. The simplest launcher of interest is the railgun, in which a short-circuit slide or an arc is driven along two rails by direct current. The most sophisticated studied thus far is the mass driver, in which a superconducting shuttle bucket is accelerated by a line of pulse coils energized by capacitors at energy conversion efficiencies better than 90%. Other accelerators of interest include helical, brush-commutated motors, discrete coil arc commutated drivers, flux compression momentum transformers, and various hybrid electrochemical devices.

  15. Topological Foundations of Electromagnetism

    CERN Document Server

    Barrett, Terrence W

    2008-01-01

    Topological Foundations of Electromagnetism seeks a fundamental understanding of the dynamics of electromagnetism; and marshals the evidence that in certain precisely defined topological conditions, electromagnetic theory (Maxwell's theory) must be extended or generalized in order to provide an explanation and understanding of, until now, unusual electromagnetic phenomena. Key to this generalization is an understanding of the circumstances under which the so-called A potential fields have physical effects. Basic to the approach taken is that the topological composition of electromagnetic field

  16. Assessment of every day extremely low frequency (Elf) electromagnetic fields (50-60 Hz) exposure: which metrics?

    International Nuclear Information System (INIS)

    Verrier, A.; Magne, I.; Souqes, M.; Lambrozo, J.

    2006-01-01

    Because electricity is encountered at every moment of the day, at home with household appliances, or in every type of transportation, people are most of the time exposed to extremely low frequency (E.L.F.) electromagnetic fields (50-60 Hz) in a various way. Due to a lack of knowledge about the biological mechanisms of 50 Hz magnetic fields, studies seeking to identify health effects of exposure use central tendency metrics. The objective of our study is to provide better information about these exposure measurements from three categories of metrics. We calculated metrics of exposure measurements from data series (79 very day exposed subjects), made up approximately 20,000 recordings of magnetic fields, measured every 30 seconds for 7 days with an E.M.D.E.X. II dosimeter. These indicators were divided into three categories : central tendency metrics, dispersion metrics and variability metrics.We use Principal Component Analysis, a multidimensional technique to examine the relations between different exposure metrics for a group of subjects. Principal component Analysis (P.C.A.) enabled us to identify from the foreground 71.7% of the variance. The first component (42.7%) was characterized by central tendency; the second (29.0%) was composed of dispersion characteristics. The third component (17.2%) was composed of variability characteristics. This study confirm the need to improve exposure measurements by using at least two dimensions intensity and dispersion. (authors)

  17. Generation of 3-D hydrostratigraphic zones from dense airborne electromagnetic data to assess groundwater model prediction error

    Science.gov (United States)

    Christensen, N. K.; Minsley, B. J.; Christensen, S.

    2017-02-01

    We present a new methodology to combine spatially dense high-resolution airborne electromagnetic (AEM) data and sparse borehole information to construct multiple plausible geological structures using a stochastic approach. The method developed allows for quantification of the performance of groundwater models built from different geological realizations of structure. Multiple structural realizations are generated using geostatistical Monte Carlo simulations that treat sparse borehole lithological observations as hard data and dense geophysically derived structural probabilities as soft data. Each structural model is used to define 3-D hydrostratigraphical zones of a groundwater model, and the hydraulic parameter values of the zones are estimated by using nonlinear regression to fit hydrological data (hydraulic head and river discharge measurements). Use of the methodology is demonstrated for a synthetic domain having structures of categorical deposits consisting of sand, silt, or clay. It is shown that using dense AEM data with the methodology can significantly improve the estimated accuracy of the sediment distribution as compared to when borehole data are used alone. It is also shown that this use of AEM data can improve the predictive capability of a calibrated groundwater model that uses the geological structures as zones. However, such structural models will always contain errors because even with dense AEM data it is not possible to perfectly resolve the structures of a groundwater system. It is shown that when using such erroneous structures in a groundwater model, they can lead to biased parameter estimates and biased model predictions, therefore impairing the model's predictive capability.

  18. A Study on the Use of Compound and Extracted Models in the High Frequency Electromagnetic Exposure Assessment

    Directory of Open Access Journals (Sweden)

    Mario Cvetković

    2017-01-01

    Full Text Available The paper presents the numerical results for the induced electric field in the various models of the human eye and the head. The comparison between the extracted or the single organ models and the compound organ models placed inside realistic head models obtained from the magnetic resonance imaging scans is presented. The numerical results for several frequencies and polarizations of the incident electromagnetic (EM plane wave are obtained using the hybrid finite element method/boundary element method (FEM/BEM formulation and the surface integral equation (SIE based formulation featuring the use of method of moments, respectively. Although some previous analysis showed the similar distribution of the induced electric field along the pupillary axis obtained in both eye models, this study showed this not to be the case in general. The analysis showed that the compound eye model is much more suitable when taking into account the polarization of the incident EM wave. The numerical results for the brain models showed much better agreement in the maximum values and distributions of the induced surface field between detailed models, while homogeneous brain model showed better agreement with the compound model in the distribution along selected sagittal axis points. The analysis could provide some helpful insights when carrying out the dosimetric analysis of the human eye and the head/brain exposed to high frequency EM radiation.

  19. Generation of 3-D hydrostratigraphic zones from dense airborne electromagnetic data to assess groundwater model prediction error

    Science.gov (United States)

    Christensen, Nikolaj K; Minsley, Burke J.; Christensen, Steen

    2017-01-01

    We present a new methodology to combine spatially dense high-resolution airborne electromagnetic (AEM) data and sparse borehole information to construct multiple plausible geological structures using a stochastic approach. The method developed allows for quantification of the performance of groundwater models built from different geological realizations of structure. Multiple structural realizations are generated using geostatistical Monte Carlo simulations that treat sparse borehole lithological observations as hard data and dense geophysically derived structural probabilities as soft data. Each structural model is used to define 3-D hydrostratigraphical zones of a groundwater model, and the hydraulic parameter values of the zones are estimated by using nonlinear regression to fit hydrological data (hydraulic head and river discharge measurements). Use of the methodology is demonstrated for a synthetic domain having structures of categorical deposits consisting of sand, silt, or clay. It is shown that using dense AEM data with the methodology can significantly improve the estimated accuracy of the sediment distribution as compared to when borehole data are used alone. It is also shown that this use of AEM data can improve the predictive capability of a calibrated groundwater model that uses the geological structures as zones. However, such structural models will always contain errors because even with dense AEM data it is not possible to perfectly resolve the structures of a groundwater system. It is shown that when using such erroneous structures in a groundwater model, they can lead to biased parameter estimates and biased model predictions, therefore impairing the model's predictive capability.

  20. Development of a source-exposure matrix for occupational exposure assessment of electromagnetic fields in the INTEROCC study.

    Science.gov (United States)

    Vila, Javier; Bowman, Joseph D; Figuerola, Jordi; Moriña, David; Kincl, Laurel; Richardson, Lesley; Cardis, Elisabeth

    2017-07-01

    To estimate occupational exposures to electromagnetic fields (EMF) for the INTEROCC study, a database of source-based measurements extracted from published and unpublished literature resources had been previously constructed. The aim of the current work was to summarize these measurements into a source-exposure matrix (SEM), accounting for their quality and relevance. A novel methodology for combining available measurements was developed, based on order statistics and log-normal distribution characteristics. Arithmetic and geometric means, and estimates of variability and maximum exposure were calculated by EMF source, frequency band and dosimetry type. The mean estimates were weighted by our confidence in the pooled measurements. The SEM contains confidence-weighted mean and maximum estimates for 312 EMF exposure sources (from 0 Hz to 300 GHz). Operator position geometric mean electric field levels for radiofrequency (RF) sources ranged between 0.8 V/m (plasma etcher) and 320 V/m (RF sealer), while magnetic fields ranged from 0.02 A/m (speed radar) to 0.6 A/m (microwave heating). For extremely low frequency sources, electric fields ranged between 0.2 V/m (electric forklift) and 11,700 V/m (high-voltage transmission line-hotsticks), whereas magnetic fields ranged between 0.14 μT (visual display terminals) and 17 μT (tungsten inert gas welding). The methodology developed allowed the construction of the first EMF-SEM and may be used to summarize similar exposure data for other physical or chemical agents.

  1. Dark Matter Interference

    DEFF Research Database (Denmark)

    Del Nobile, Eugenio; Kouvaris, Christoforos; Sannino, Francesco

    2012-01-01

    We study different patterns of interference in WIMP-nuclei elastic scattering that can accommodate the DAMA and CoGeNT experiments via an isospin violating ratio $f_n/f_p=-0.71$. We study interference between the following pairs of mediators: Z and Z', Z' and Higgs, and two Higgs fields. We show ...

  2. THE MEASUREMENT ELECTROMAGNETIC INTERFERENCE IN THE REVERSE TRACTION NETWORK

    Directory of Open Access Journals (Sweden)

    T. M. Serdiuk

    2009-09-01

    Full Text Available The original automated method of measurement of electrical noise in the return electric-traction network is proposed. It is realized on the base of car-laboratory “Automatics, telemechanics and communication”. The mathematic model of return electric-traction network is developed to scientific bases of automated measurement. It allows us obtaining the mathematic expressions for change of voltage and current harmonics in the rail net and taking into account the inhomogeneity of lines for the following analytic determination of a source of electric noise.

  3. Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide

    Science.gov (United States)

    Wheeler, M. L.

    1998-01-01

    The objective of this test guide is to document appropriate unit level test methods and techniques for the performance of EMI testing of Direct Sequence (DS) spread spectrum receivers. Consideration of EMI test methods tailored for spread spectrum receivers utilizing frequency spreading, techniques other than direct sequence (such as frequency hopping, frequency chirping, and various hybrid methods) is beyond the scope of this test guide development program and is not addressed as part of this document EMI test requirements for NASA programs are primarily developed based on the requirements contained in MIL-STD-46 1 D (or earlier revisions of MIL-STD-46 1). The corresponding test method guidelines for the MIL-STD-461 D tests are provided in MIL-STD-462D. These test methods are well documented with the exception of the receiver antenna port susceptibility tests (intermodulation, cross modulation, and rejection of undesired signals) which must be tailored to the specific type of receiver that is being tested. Thus, test methods addressed in this guide consist only of antenna port tests designed to evaluate receiver susceptibility characteristics. MIL-STD-462D should be referred for guidance pertaining to test methods for EMI tests other than the antenna port tests. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.

  4. Renewable Energy, Photovoltaic Systems Near Airfields: Electromagnetic Interference

    Science.gov (United States)

    2015-04-01

    equipment to this standard and it is easily validated when procuring equipment. The FCC limits specify an upper bound on the amount of radiated ...60 Hz) operation. TYPICAL EMISSION SPECTRA AND COUNTERMEASURES Compliance with FCC Part 15 radiated specification does not guarantee a lack of ...TECHNIQUE To conduct field measurements of radiated emission, a wide-band spectrum analyzer with sensitivity down to 150 kHz is required, along with an

  5. Electromagnetic aquametry electromagnetic wave interaction with water and moist substances

    CERN Document Server

    Kupfer, Klaus

    2006-01-01

    This book covers all aspects of Electromagnetic Aquametry. It summarizes the wide area of metrology and its applications in electromagnetic sensing of moist materials. The physical properties of water in various degrees of binding interacting with electromagnetic fields is presented by model systems. The book describes measurement methods and sensors in the frequency domain, TDR-techniques for environmental problems, methods and sensors for quality assessment of biological substances, and nuclear magnetic resonance techniques. Environmental sciences, as well as civil and geoengineering, fossil fuels, food and pharmaceutical science are the main fields of application. A very wide frequency sprectrum is used for dielectric measurement methods, but the microwave range is clearly dominant. Multiparameter methods as well as methods of principal components and artificial neural networks for density independent measurements are described.

  6. Interference of Multiple Surface Plasmon Polaritons

    International Nuclear Information System (INIS)

    Wang, Dapeng; Yuan, Xiaocong; Lin, Jiao

    2017-01-01

    Benefiting from strongly electromagnetic confinement and enhancement effects, surface plasmon polaritons (SPPs) hold great promises for tailoring light on micro and nanoscale. By contrast with previous efforts which massively concentrate on localized SPP mode, we investigated the propagating SPPs in this paper. A number of symmetrical gratings on metal surface are employed to excite multiple SPPs. Interestingly, the exotic interfering phenomena have been observed. They show good agreement with free-space interferences and take advantage of precise controllability. These findings will be promising in the applications of optical tweezers and SPP lithography. (paper)

  7. Cell-phone interference with pocket dosimeters

    International Nuclear Information System (INIS)

    Djajaputra, David; Nehru, Ramasamy; Bruch, Philip M; Ayyangar, Komanduri M; Raman, Natarajan V; Enke, Charles A

    2005-01-01

    Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag. (note)

  8. Cell-phone interference with pocket dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Djajaputra, David; Nehru, Ramasamy; Bruch, Philip M; Ayyangar, Komanduri M; Raman, Natarajan V; Enke, Charles A [Department of Radiation Oncology, University of Nebraska Medical Center, 987521 Nebraska Medical Center, Omaha, NE 68198-7521 (United States)

    2005-05-07

    Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag. (note)

  9. Hearing aids' electromagnetic immunity to environmental RF fields

    International Nuclear Information System (INIS)

    Facta, S.; Benedetto, A.; Anglesio, L.; D'Amore, G.

    2004-01-01

    In this work, the electromagnetic interference on hearing aids was evaluated. Electromagnetic (EM) immunity tests on different types of hearing aids were carried out, using signals of intensity and modulation comparable to those present in the environment. The purpose of this work is to characterise the interference, establishing the immunity threshold for different frequencies and finding out which types of hearing aids are more susceptible, and in which frequency range. The tests were carried out in a GTEM cell on seven hearing aids, using AM and GSM signals in the radiofrequency (RF) range. (authors)

  10. Intermediate energy electromagnetic interactions

    International Nuclear Information System (INIS)

    Garcon, M.

    1994-11-01

    Polarization measurements in electromagnetic interactions are reviewed. Deep inelastic scattering of polarized electrons and muons an polarized targets, photoproduction of pseudoscalar mesons on protons, photonuclear reactions, and the electromagnetic structure of the deuteron are discussed. (K.A.)

  11. Intermediate energy electromagnetic interactions

    Energy Technology Data Exchange (ETDEWEB)

    Garcon, M.

    1994-11-01

    Polarization measurements in electromagnetic interactions are reviewed. Deep inelastic scattering of polarized electrons and muons an polarized targets, photoproduction of pseudoscalar mesons on protons, photonuclear reactions, and the electromagnetic structure of the deuteron are discussed. (K.A.).

  12. Electromagnetic wave matching device

    International Nuclear Information System (INIS)

    Hirata, Yosuke; Mitsunaka, Yoshika; Hayashi, Ken-ichi; Ito, Yasuyuki.

    1997-01-01

    The present invention provides an electromagnetic wave matching capable of reducing a cost for the transmission system in a system of using electromagnetic waves for plasma heating of a thermonuclear reactor. Namely, incident electromagnetic waves are reflected by using a plurality of phase correction mirrors. The reflected electromagnetic waves are connected to an external transmission system through an exit. The phase correction mirrors have such a shape to receive a plurality of beam-like electromagnetic waves and output electromagnetic waves by the number different from the number of the received electromagnetic wave beams having a predetermined distribution. Further, at least two of the phase correction mirrors have such a shape to change the phase of the electromagnetic waves beams incident to the reflection surface of the phase correction mirrors by a predetermined amount corresponding to the position of the reflection surface. Then, the cost for transmission system can greatly be reduced. (I.S.)

  13. Combined effects of 60Co dose and high frequency interferences on a discrete bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Raoult, J.; Jarrix, S.; Blain, A.; Dusseau, L.; Hoffmann, P.; Chatry, N.; Calvel, P.

    2012-01-01

    This paper concerns bipolar transistors subject to a double aggression: dose irradiation and high-frequency interference. The electromagnetic interference is injected in a contactless way in the near-field zone around the device. Parameters of the interference are power and frequency, the latter largely out of band of operation of the transistors. The output voltage of the transistor exhibits changes, due to rectification and to some extent to current crowding. The importance of the base bias set-up for the type of change occurring in voltage is displayed. After irradiation with a 60 Co source, the voltage output will change under electromagnetic interference but sometimes in an opposite way as initially measured. The impact of the irradiation with respect to electromagnetic susceptibility is highlighted from a physical point of view. Finally preliminary results of simulation for susceptibility prediction are given and a discussion is given on the limits of the transistor model used. (authors)

  14. Electromagnetic Education in India

    Science.gov (United States)

    Bajpai, Shrish; Asif, Siddiqui Sajida; Akhtar, Syed Adnan

    2016-01-01

    Out of the four fundamental interactions in nature, electromagnetics is one of them along with gravitation, strong interaction and weak interaction. The field of electromagnetics has made much of the modern age possible. Electromagnets are common in day-to-day appliances and are becoming more conventional as the need for technology increases.…

  15. Electromagnetic signatures of far-field gravitational radiation in the 1 + 3 approach

    International Nuclear Information System (INIS)

    Chua, Alvin J K; Cañizares, Priscilla; Gair, Jonathan R

    2015-01-01

    Gravitational waves (GWs) from astrophysical sources can interact with background electromagnetic fields, giving rise to distinctive and potentially detectable electromagnetic signatures. In this paper, we study such interactions for far-field gravitational radiation using the 1 + 3 approach to relativity. Linearized equations for the electromagnetic field on perturbed Minkowski space are derived and solved analytically. The inverse Gertsenshteĭn conversion of GWs in a static electromagnetic field is rederived, and the resultant electromagnetic radiation is shown to be significant for highly magnetized pulsars in compact binary systems. We also obtain a variety of nonlinear interference effects for interacting gravitational and electromagnetic waves, although wave–wave resonances previously described in the literature are absent when the electric–magnetic self-interaction is taken into account. The fluctuation and amplification of electromagnetic energy flux as the GW strength increases towards the gravitational–electromagnetic frequency ratio is a possible signature of gravitational radiation from extended astrophysical sources. (paper)

  16. Electromagnetic fields: the new European directive

    International Nuclear Information System (INIS)

    Moureaux, Patrick

    2014-01-01

    A European directive is specifying the thresholds for exposure to electromagnetic fields. The risk assessment approach proposed should enable worker health to be taken better into account. An overview of the new provisions. (author)

  17. [Experimental research on the electromagnetic radiation immunity of a kind of portable monitor].

    Science.gov (United States)

    Yuan, Jun; Xiao, Dongping; Jian, Xin

    2010-11-01

    The paper is focused on a kind of portable monitor that is widely used in military hospitals. In order to study the electromagnetic radiation immunity of the monitor, the experiments of electromagnetic radiation caused by radio frequency continuous wave in reverberation chamber and by ultra wide band (UWB) electromagnetic pulse have been done. The study results show that UWB electromagnetic pulse interferes observably the operating state of the monitor. It should be paid high attention to take protective measures. The monitor tested has some electromagnetic immunity ability for radio frequency continuous wave radiation. The frequent abnormal phenomena are baseline drift and waveform distortion. The electromagnetic sensitivity of the monitor is related to the frequency of interference source. The monitor tested is most sensitive to the frequency of 390 MHz.

  18. Review of Studies Concerning Electromagnetic Field (EMF Exposure Assessment in Europe: Low Frequency Fields (50 Hz–100 kHz

    Directory of Open Access Journals (Sweden)

    Peter Gajšek

    2016-09-01

    Full Text Available We aimed to review the findings of exposure assessment studies done in European countries on the exposure of the general public to low frequency electric and magnetic fields (EMFs of various frequencies. The study shows that outdoor average extremely low frequency magnetic fields (ELF-MF in public areas in urban environments range between 0.05 and 0.2 µT in terms of flux densities, but stronger values (of the order of a few µT may occur directly beneath high-voltage power lines, at the walls of transformer buildings, and at the boundary fences of substations. In the indoor environment, high values have been measured close to several domestic appliances (up to the mT range, some of which are held close to the body, e.g., hair dryers, electric shavers. Common sources of exposure to intermediate frequencies (IF include induction cookers, compact fluorescent lamps, inductive charging systems for electric cars and security or anti-theft devices. No systematic measurement surveys or personal exposimetry data for the IF range have been carried out and only a few reports on measurements of EMFs around such devices are mentioned. According to the available European exposure assessment studies, three population exposure categories were classified by the authors regarding the possible future risk analysis. This classification should be considered a crucial advancement for exposure assessment, which is a mandatory step in any future health risk assessment of EMFs exposure.

  19. Review of Studies Concerning Electromagnetic Field (EMF) Exposure Assessment in Europe: Low Frequency Fields (50 Hz–100 kHz)

    Science.gov (United States)

    Gajšek, Peter; Ravazzani, Paolo; Grellier, James; Samaras, Theodoros; Bakos, József; Thuróczy, György

    2016-01-01

    We aimed to review the findings of exposure assessment studies done in European countries on the exposure of the general public to low frequency electric and magnetic fields (EMFs) of various frequencies. The study shows that outdoor average extremely low frequency magnetic fields (ELF-MF) in public areas in urban environments range between 0.05 and 0.2 µT in terms of flux densities, but stronger values (of the order of a few µT) may occur directly beneath high-voltage power lines, at the walls of transformer buildings, and at the boundary fences of substations. In the indoor environment, high values have been measured close to several domestic appliances (up to the mT range), some of which are held close to the body, e.g., hair dryers, electric shavers. Common sources of exposure to intermediate frequencies (IF) include induction cookers, compact fluorescent lamps, inductive charging systems for electric cars and security or anti-theft devices. No systematic measurement surveys or personal exposimetry data for the IF range have been carried out and only a few reports on measurements of EMFs around such devices are mentioned. According to the available European exposure assessment studies, three population exposure categories were classified by the authors regarding the possible future risk analysis. This classification should be considered a crucial advancement for exposure assessment, which is a mandatory step in any future health risk assessment of EMFs exposure. PMID:27598182

  20. High frequency electromagnetic processes in induction motors supplied from PWM inverters

    Directory of Open Access Journals (Sweden)

    Ioan Ţilea

    2010-12-01

    Full Text Available The paper presents the electromagnetic interference between induction motors and inverters when at high frequency electromagnetic process appears in induction motors having a parallel resonant effect because of parasitic capacitive coupling between windings and ground, using a numerical model in simulink and a high frequency induction motor equivalent circuit model this effect is shown.

  1. An electromagnetic field measurement protocol for monitoring power lines

    International Nuclear Information System (INIS)

    Lubritto, C.; Iavazzo, A.; D'Onofrio, A.; Palmieri, A.; Sabbarese, C.; Terrasi, F.

    2002-01-01

    In the actions aiming to prevent risks related to the exposure to Low Frequencies Non Ionising electromagnetic Radiations (ELF-NIR), always arises the need to perform measurements in order to assess the field level existing in the considered sites. As a matter of fact very often it turns out difficult to predict, on the base of calculations, with sufficient approximation the field levels, due to extended variability of environmental conditions (e.g. coexistence of several sources, ground and building conformation, etc..). The measurement procedures must follow a methodology that could allow to minimise the interferences with the measurement set-up and the systematic and accidental errors. Risks for the operator and damages to the instrument should also be taken into account. One of the goal set for this research program was then the definition of the measurement protocol for electromagnetic field generated by low frequency non ionising radiation sources. In particular sources like power lines will be considered in order to validate the protocol by means of in-field measurements

  2. A Circuit Design and its Experimental Analysis for Electromagnetic Flowmeter in Measurement of Sewage

    OpenAIRE

    Huang Yu-Hang; Zhu Wei-Hua; Jiang Xingfang

    2014-01-01

    There are many problems in the traditional electromagnetic flowmeter. The problems involve three aspects. The first one is that the measurement precision is low. The second one is that the measurement range is narrow. The third one is that the test results are susceptible to interference. For the problems a new electromagnetic flowmeter controlled by single-chip microcomputer has been proposed. The medium/large-sized electromagnetic flowmeter is suitable for measurement of sewage. The softwar...

  3. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  4. An update on mobile phones interference with medical devices

    International Nuclear Information System (INIS)

    Pashazadeh, A. M.; Aghajani, M.; Nabipour, I.; Assadi, M.

    2013-01-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems. (authors)

  5. An update on mobile phones interference with medical devices.

    Science.gov (United States)

    Mahmoud Pashazadeh, Ali; Aghajani, Mahdi; Nabipour, Iraj; Assadi, Majid

    2013-10-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems.

  6. Tracking Electromagnetic Energy With SQUIDs

    Science.gov (United States)

    2005-01-01

    A superconducting quantum interference device (SQUID) is a gadget used to measure extremely weak signals, specifically magnetic flux. It can detect subtle changes in energy, up to 100 billion times weaker than the electromagnetic energy required to move a compass needle. SQUIDs are used for a variety of testing procedures where extreme sensitivity is required and where the test instrument need not come into direct contact with the test subject. NASA uses SQUIDs for remote, noncontact sensing in a variety of venues, including monitoring the Earth s magnetic field and tracking brain activity of pilots. Scientists at NASA s Goddard Space Flight Center have been making extensive use of this technology, from astrophysical research, to tracking the navigational paths of bees in flight to determine if they are using internal compasses. These very sensitive measurement devices have a wide variety of uses within NASA and even more uses within the commercial realm.

  7. An improved procedure to accurately assess the variability of the exposure to electromagnetic radiation emitted by GSM base station antennas

    International Nuclear Information System (INIS)

    Bechet, Paul; Miclaus, Simona

    2013-01-01

    Long-term human exposure around Global System for Mobile Communications (GSM) base station antennas has not yet been precisely established; this is of interest from human health and epidemiological perspectives. Actual exposure is difficult to assess accurately, mainly because there is a lack of technical information directly from the GSM operators. The in situ measurement standards available at present provide only a worst-case prediction method; the present work goes beyond this and proposes a methodology that, without the need for data from operators, allows a reliable way to express real exposure with a greater accuracy than all other methods proposed to date. The method is based on dual measurements of the signal strengths in the frequency domain and the time domain and takes into consideration the instantaneous traffic in GSM channels. In addition, it allows a channel-individualized exposure assessement, by making possible the separate analysis of the electric field level in the two types of channel of the GSM standard—the traffic channels and the control channels. (paper)

  8. On assessing electromagnetic field (300 kmhz – 300mhz in a large industrial city on the basis of 3d modeling and instrumental measuring

    Directory of Open Access Journals (Sweden)

    I.V. May

    2017-09-01

    Full Text Available The article dwells on issues of modeling electromagnetic fields levels (EMF with frequency equal to 300 KMHz - 300 MHz which are created by television and radio broadcasting objects, radiolocation, and mobile communication in a large regional cen-ter, in geoinformation system environment. Our task was to estimate EMF levels on areas where apartment blocks were located; to assess energy flows at various floors, to determine zones in a city as per EMF levels; to verify the obtained results with the direct factor measuring. Our calculation included data on 2,011 EMF sources located on a city territory. We allowed for bulk parameters of 31,949 buildings including 17,307 apartment blocks, 3,160 administrative buildings, 307 pre-school children facilities and 105 secondary schools. We performed our calculations in city coordinate system at 109 thousand points. Each calculation created a picture of EMF spread in a plane at a set height which allowed us to determine exposure level at a control point as per "slice" re-sults and to build up a 3D contamination model. Approximately 80% of all the calculated results had EMF parameters within 0.1-10 safety criterion range. We spotted zones with maximum calculated EMF levels at 18-25 meters. Instrumental research proved high factor levels in these zones including those where levels exceeded safety criterion 4-6 times; it makes for certain vigilance in judgments on environmental safety for people who live on the examined territory permanently. The obtained data can be used for foundation of instrumental research points within the frameworks of specific research or social-hygienic monitoring as well as for consequent exposure and health risk assessment. The materials can be used in epidemiologic research for conjugate spatial analysis of energy flows and children and adults mortality.

  9. Hazard Monitoring in a Spectrum-Challenged Future: US Department of Transportation Adjacent Band Compatibility Assessment of Interference on High-Precision GNSS Receivers

    Science.gov (United States)

    Blume, F.; Berglund, H. T.

    2016-12-01

    In 2012 the Federal Communications Commission (FCC) reversed its decision to allow communications company LightSquared to use GPS-adjacent spectrum for a ground based network after testing demonstrated harmful interference to GPS receivers. Now rebranded as Ligado, they have submitted modified application to use a smaller portion of the L-band spectrum at much lower power. Many GPS community stakeholders, including the hazard monitoring and EEW communities remain concerned that Ligado's proposed use could still cause harmful interference, causing signal degradation, real-time positioning errors, and total failure of GNSS hardware in widespread use in hazard monitoring networks. The Department of Transportation (DoT) has conducted hardware tests to determine adjacent-band transmitter power limit criteria that would prevent harmful interference from Ligado's operations. We present preliminary results produced from the data collected by the three UNAVCO receiver types tested: Trimble NetRS, Trimble NetR9, and Septentrio PolaRx5. In the first round of testing, simulated GNSS signals were broadcast in an anechoic chamber (pictured below) while interfering signals are broadcast simultaneously with varying amplitude and frequency. The older GPS-only NetRS receiver showed smaller reductions in SNR at frequencies adjacent to GPS L1 as compared to the other receivers, suggesting narrower L1 filter bandwidth in the RF frontend. The NetR9 showed greater decreases in observed SNR in the 1615 to 1625 MHz range when compared to the other two receivers. This suggests that the NetR9's L1 filter bandwidth has been increased to accommodate GNSS signals. Linearity tests were conducted to better relate SNR measurements between receiver types. The PolaRx5 receiver showed less SNR variation between tracking channels than both Trimble receivers. Our results show the power levels at which adjacent-band interference begins degrading receiver performance and eventually disables tracking. As

  10. Interference and Sensitivity Analysis.

    Science.gov (United States)

    VanderWeele, Tyler J; Tchetgen Tchetgen, Eric J; Halloran, M Elizabeth

    2014-11-01

    Causal inference with interference is a rapidly growing area. The literature has begun to relax the "no-interference" assumption that the treatment received by one individual does not affect the outcomes of other individuals. In this paper we briefly review the literature on causal inference in the presence of interference when treatments have been randomized. We then consider settings in which causal effects in the presence of interference are not identified, either because randomization alone does not suffice for identification, or because treatment is not randomized and there may be unmeasured confounders of the treatment-outcome relationship. We develop sensitivity analysis techniques for these settings. We describe several sensitivity analysis techniques for the infectiousness effect which, in a vaccine trial, captures the effect of the vaccine of one person on protecting a second person from infection even if the first is infected. We also develop two sensitivity analysis techniques for causal effects in the presence of unmeasured confounding which generalize analogous techniques when interference is absent. These two techniques for unmeasured confounding are compared and contrasted.

  11. Binaural Interference: Quo Vadis?

    Science.gov (United States)

    Jerger, James; Silman, Shlomo; Silverman, Carol; Emmer, Michele

    2017-04-01

    The reality of the phenomenon of binaural interference with speech recognition has been debated for two decades. Research has taken one of two avenues; group studies or case reports. In group studies, a sample of the elderly population is tested on speech recognition under three conditions; binaural, monaural right and monaural left. The aim is to determine the percent of the sample in which the expected outcome (binaural score-better-than-either-monaural score) is reversed (i.e., one of the monaural scores is better than the binaural score). This outcome has been commonly used to define binaural interference. The object of group studies is to answer the "how many" question, what is the prevalence of binaural interference in the sample. In case reports the binaural interference conclusion suggested by the speech recognition tests is not accepted until it has been corroborated by other independent diagnostic audiological measures. The aim is to attempt to determine the basis for the findings, to answer the "why" question. This article is at once tutorial, editorial and a case report. We argue that it is time to accept the reality of the phenomenon of binaural interference, to eschew group statistical approaches in search of an answer to the "how many" question, and to focus on individual case reports in search of an answer to the "why" question. American Academy of Audiology.

  12. Human response to interference with TV picture quality

    Energy Technology Data Exchange (ETDEWEB)

    Janischewskyj, W.; Harvey, E.B.

    1980-10-01

    Corona on transmission line conductors and spark gaps on loose or defective transmission line hardware can give rise to visual interference to television interference. The extent to which the interference is a concern (i.e., annoying) depends on the intensity of the interference as well as the strength of the television signal and can best be expressed as a function of the signal-to-noise ratio (SNR), the decibel difference between the wanted signal and the unwanted noise (interference). The study documented in this report has assessed, through subjective testing involving over 500 subjects, the interference level, as a function of SNR, of three different sources of interference: wet-weather conductor corona, a large spark gap (5 mm), and a small spark gap (0.8 mm). The results of the study should be particularly useful to the utility industry in assessing the environmental impact of high-voltage transmission lines.

  13. On scattering of electromagnetic waves by a wormhole

    International Nuclear Information System (INIS)

    Kirillov, A.A.; Savelova, E.P.

    2012-01-01

    We consider scattering of a plane electromagnetic wave by a wormhole. It is found that the scattered wave is depolarized and has a specific interference picture depending on parameters of the wormhole and the distance to the observer. It is proposed that such features can be important in the direct search of wormholes.

  14. On scattering of electromagnetic waves by a wormhole

    Energy Technology Data Exchange (ETDEWEB)

    Kirillov, A.A., E-mail: ka98@mail.ru [Dubna International University of Nature, Society and Man, Universitetskaya Str. 19, Dubna, 141980 (Russian Federation); Savelova, E.P. [Dubna International University of Nature, Society and Man, Universitetskaya Str. 19, Dubna, 141980 (Russian Federation)

    2012-04-20

    We consider scattering of a plane electromagnetic wave by a wormhole. It is found that the scattered wave is depolarized and has a specific interference picture depending on parameters of the wormhole and the distance to the observer. It is proposed that such features can be important in the direct search of wormholes.

  15. Effect of Mobile Phone Radiofrequency Electromagnetic Fields on ...

    African Journals Online (AJOL)

    Summary: Since cell phones emit radiofrequency electromagnetic fields (EMFs), this study tested the hypothesis that cell phones placed near the heart may interfere with the electrical rhythm of the heart or affect the blood pressure. Following informed consent, eighteen randomly selected apparently healthy male volunteers ...

  16. Electromagnetic energy flow lines as possible paths of photons

    Energy Technology Data Exchange (ETDEWEB)

    Davidovic, M [Faculty of Civil Engineering, University of Belgrade, Bulevar Kralja Aleksandra 73, 11000 Belgrade (Serbia); Sanz, A S; Miret-Artes, S [Instituto de Fisica Fundamental, Consejo Superior de Investigaciones CientIficas, Serrano 123, 28006 Madrid (Spain); Arsenovic, D; Bozic, M [Institute of Physics, University of Belgrade, Pregrevica 118, 11080 Belgrade (Serbia)], E-mail: milena@grf.bg.ac.yu, E-mail: asanz@imaff.cfmac.csic.es, E-mail: arsenovic@phy.bg.ac.yu, E-mail: bozic@phy.bg.ac.yu, E-mail: s.miret@imaff.cfmac.csic.es

    2009-07-15

    Motivated by recent experiments where interference patterns behind a grating are obtained by accumulating single photon events, we provide here an electromagnetic energy flow-line description to explain the emergence of such patterns. We find and discuss an analogy between the equation describing these energy flow lines and the equation of Bohmian trajectories used to describe the motion of massive particles.

  17. The design of a miniature personal exposure monitor for continuous real-time data acquisition in electromagnetic field exposure assessment

    International Nuclear Information System (INIS)

    Hansen, N.H.; Conroy, T.J.; Wilson, B.W.

    1994-06-01

    The design of a small, light-weight personal exposure monitor suitable for use in EMF exposure assessment studies is nearing completion at Pacific Northwest Laboratory. The monitor is designed to be non-obtrusive, battery operated, and able to continuously record extremely low-frequency (ELF) (1Ohz--500hz) magnetic-field data. It also captures high-frequency (500hz--1OMhz) transients that exceed a preset threshold, retaining the largest transients in memory. The monitor can record one or more days of data on a single easily replaceable, credit-card-size memory (PCMCIA). A battery charge will last a minimum of one day. Batteries are rechargeable and easily replaced. A data-compression algorithm is under development that will be tailored to the efficient compression of low-frequency EMF signals and will permit data to be logged for at least one day before swapping memory cards. The memory cards are readable by a base- station computer that can perform analysis of the data. The monitor is designed to accommodate four inputs supporting full-field sensors as well as a proposed ocular exposure measurement system. Our design effort has shown that a practical personal exposure monitor for EMF can be built based on current technology, continuous logging of real-time ELF waveforms is both feasible and practical, and such a device is appropriate for proposed EMF exposure studies

  18. CERN Technical Training 2002: Learning for the LHC! Electromagnetic Compatibility (EMC): Introduction

    CERN Multimedia

    Davide Vitè

    2002-01-01

    A new session of the course Electromagnetic Compatibility (EMC): Introduction will be held on May 22 (am), in the framework of the CERN Technical Training Programme. This session, bilingual English-French, is free of charge, and will be given by F. Szoncso of TIS-GS division. The course is designed for physicists, engineers and technicians facing electromagnetic interference problems, and will describe the underlying phenomena and mechanisms of electromagnetic interference and their remedies. More information and online registration by EDH are available from the Technical Training "Electronics Design" pages, under the chapter "Miscellaneous". Please contact Technical.Training@cern.ch should you need any other information.

  19. Assessment of personal exposure from radiofrequency-electromagnetic fields in Australia and Belgium using on-body calibrated exposimeters.

    Science.gov (United States)

    Bhatt, Chhavi Raj; Thielens, Arno; Billah, Baki; Redmayne, Mary; Abramson, Michael J; Sim, Malcolm R; Vermeulen, Roel; Martens, Luc; Joseph, Wout; Benke, Geza

    2016-11-01

    The purposes of this study were: i) to demonstrate the assessment of personal exposure from various RF-EMF sources across different microenvironments in Australia and Belgium, with two on-body calibrated exposimeters, in contrast to earlier studies which employed single, non-on-body calibrated exposimeters; ii) to systematically evaluate the performance of the exposimeters using (on-body) calibration and cross-talk measurements; and iii) to compare the exposure levels measured for one site in each of several selected microenvironments in the two countries. A human subject took part in an on-body calibration of the exposimeter in an anechoic chamber. The same subject collected data on personal exposures across 38 microenvironments (19 in each country) situated in urban, suburban and rural regions. Median personal RF-EMF exposures were estimated: i) of all microenvironments, and ii) across each microenvironment, in two countries. The exposures were then compared across similar microenvironments in two countries (17 in each country). The three highest median total exposure levels were: city center (4.33V/m), residential outdoor (urban) (0.75V/m), and a park (0.75V/m) [Australia]; and a tram station (1.95V/m), city center (0.95V/m), and a park (0.90V/m) [Belgium]. The exposures across nine microenvironments in Melbourne, Australia were lower than the exposures across corresponding microenvironments in Ghent, Belgium (p<0.05). The personal exposures across urban microenvironments were higher than those for rural or suburban microenvironments. Similarly, the exposure levels across outdoor microenvironments were higher than those for indoor microenvironments. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Generalized Multiphoton Quantum Interference

    Directory of Open Access Journals (Sweden)

    Max Tillmann

    2015-10-01

    Full Text Available Nonclassical interference of photons lies at the heart of optical quantum information processing. Here, we exploit tunable distinguishability to reveal the full spectrum of multiphoton nonclassical interference. We investigate this in theory and experiment by controlling the delay times of three photons injected into an integrated interferometric network. We derive the entire coincidence landscape and identify transition matrix immanants as ideally suited functions to describe the generalized case of input photons with arbitrary distinguishability. We introduce a compact description by utilizing a natural basis that decouples the input state from the interferometric network, thereby providing a useful tool for even larger photon numbers.

  1. Interference in immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Interfering factors are evident in both limited reagent (radioimmunoassay) and excess reagent (immunometric assay) technologies and should be suspected whenever there is a discrepancy between analytical results and clinical findings in the investigation of particular diseases. The overall effect of interference in immunoassay is analytical bias in result, either positive or negative of variable magnitude. The interference maybe caused by a wide spectrum of factors from poor sample collection and handling to physiological factors e.g. lipaemia, heparin treatment, binding protein abnormalities, autoimmunity and drug treatments. The range of interfering factors is extensive and difficult to discuss effectively in a short review

  2. Electromagnetic wave matching device

    International Nuclear Information System (INIS)

    Hirata, Yosuke; Mitsunaka, Yoshika; Hayashi, Ken-ichi; Ito, Yasuyuki.

    1997-01-01

    The present invention provides a matching device capable of increasing an efficiency of combining beams of electromagnetic waves outputted from an output window of a gyrotron which is expected for plasma heating of a thermonuclear reactor and an electromagnetic wave transmission system as high as possible. Namely, an electromagnetic wave matching device reflects beams of electromagnetic waves incident from an inlet by a plurality of phase correction mirrors and combines them to an external transmission system through an exit. In this case, the phase correction mirrors change the phase of the beams of electromagnetic waves incident to the phase correction mirrors by a predetermined amount corresponding to the position of the reflection mirrors. Then, the beams of electromagnetic waves outputted, for example, from a gyrotron can properly be shaped as desired for the intensity and the phase. As a result, combination efficiency with the transmission system can be increased. (I.S.)

  3. Electromagnetic Gowdy universe

    International Nuclear Information System (INIS)

    Charach, C.

    1979-01-01

    Following Gowdy and Berger we construct an inhomogeneous closed electromagnetic universe with three-torus topology. This model is obtained as a result of the homogeneity breaking in the electromagnetic Bianchi type-I universe and contains interacting gravitational and electromagnetic waves. This cosmological solution provides an exactly solvable model for the study of the nonlinear fully relativistic regime of coupled electromagnetic and gravitational fields in the early universe. The asymptotic behavior is considered (i) in the vicinity of the initial singularity and (ii) in the high-frequency limit. It is shown that the effects of coupling between electromagnetic and gravitational waves cause an evolution which is significantly different from that of the vacuum model. The influence of the primordial homogeneous electromagnetic field on the dynamics of the model is also discussed

  4. Electromagnetic ultrasonic guided waves

    CERN Document Server

    Huang, Songling; Li, Weibin; Wang, Qing

    2016-01-01

    This book introduces the fundamental theory of electromagnetic ultrasonic guided waves, together with its applications. It includes the dispersion characteristics and matching theory of guided waves; the mechanism of production and theoretical model of electromagnetic ultrasonic guided waves; the effect mechanism between guided waves and defects; the simulation method for the entire process of electromagnetic ultrasonic guided wave propagation; electromagnetic ultrasonic thickness measurement; pipeline axial guided wave defect detection; and electromagnetic ultrasonic guided wave detection of gas pipeline cracks. This theory and findings on applications draw on the author’s intensive research over the past eight years. The book can be used for nondestructive testing technology and as an engineering reference work. The specific implementation of the electromagnetic ultrasonic guided wave system presented here will also be of value for other nondestructive test developers.

  5. Basic Electromagnetism and Materials

    CERN Document Server

    Moliton, André

    2007-01-01

    Basic Electromagnetism and Materials is the product of many years of teaching basic and applied electromagnetism. This textbook can be used to teach electromagnetism to a wide range of undergraduate science majors in physics, electrical engineering or materials science. However, by making lesser demands on mathematical knowledge than competing texts, and by emphasizing electromagnetic properties of materials and their applications, this textbook is uniquely suited to students of materials science. Many competing texts focus on the study of propagation waves either in the microwave or optical domain, whereas Basic Electromagnetism and Materials covers the entire electromagnetic domain and the physical response of materials to these waves. Professor André Moliton is Director of the Unité de Microélectronique, Optoélectronique et Polymères (Université de Limoges, France), which brings together three groups studying the optoelectronics of molecular and polymer layers, micro-optoelectronic systems for teleco...

  6. Electromagnetic Compatibility in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Ewing, P.D.; Kercel, S.W.; Korsah, K.; Wood, R.T.

    1999-01-01

    Electromagnetic compatibility (EMC) has long been a key element of qualification for mission critical instrumentation and control (I ampersand C) systems used by the U.S. military. The potential for disruption of safety-related I ampersand C systems by electromagnetic interference (EMI), radio-frequency interference (RFI), or power surges is also an issue of concern for the nuclear industry. Experimental investigations of the potential vulnerability of advanced safety systems to EMI/RFI, coupled with studies of reported events at nuclear power plants (NPPs) that are attributed to EMI/RFI, confirm the safety significance of EMC for both analog and digital technology. As a result, Oak Ridge National Laboratory has been engaged in the development of the technical basis for guidance that addresses EMC for safety-related I ampersand C systems in NPPs. This research has involved the identification of engineering practices to minimize the potential impact of EMI/RFI and power surges and an evaluation of the ambient electromagnetic environment at NPPs to tailor those practices for use by the nuclear industry. Recommendations for EMC guidance have been derived from these research findings and are summarized in this paper

  7. Review on Computational Electromagnetics

    Directory of Open Access Journals (Sweden)

    P. Sumithra

    2017-03-01

    Full Text Available Computational electromagnetics (CEM is applied to model the interaction of electromagnetic fields with the objects like antenna, waveguides, aircraft and their environment using Maxwell equations.  In this paper the strength and weakness of various computational electromagnetic techniques are discussed. Performance of various techniques in terms accuracy, memory and computational time for application specific tasks such as modeling RCS (Radar cross section, space applications, thin wires, antenna arrays are presented in this paper.

  8. Static electromagnetic frequency changers

    CERN Document Server

    Rozhanskii, L L

    1963-01-01

    Static Electromagnetic Frequency Changers is about the theory, design, construction, and applications of static electromagnetic frequency changers, devices that used for multiplication or division of alternating current frequency. It is originally published in the Russian language. This book is organized into five chapters. The first three chapters introduce the readers to the principles of operation, the construction, and the potential applications of static electromagnetic frequency changers and to the principles of their design. The two concluding chapters use some hitherto unpublished work

  9. Assessment of Slope Stability and Interference of Structures Considering Seismity in Complex Engineering-Geological Conditions Using the Method of Finite Elements

    International Nuclear Information System (INIS)

    Menabdishvili, Papuna; Eremadze, Nelly

    2008-01-01

    There is elaborated the calculation model of slope deformation mode stability and the methodic of calculation considering the interference of structures to be built on it using the method of finite elements. There is examined the task of slope stability using the soil physically nonlinear finite element considering the seismicity 8. The deformation mode and field of coefficients of stability are obtained and slope supposed sliding curve is determined. The elaborated calculation methodic allows to determine the slope deformation mode, stability and select the optimum version of structure foundation at any slant and composition of slope layers

  10. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  11. The MOBI-Kids Study Protocol: Challenges in Assessing Childhood and Adolescent Exposure to Electromagnetic Fields from Wireless Telecommunication Technologies and Possible Association with Brain Tumor Risk

    Science.gov (United States)

    Sadetzki, Siegal; Langer, Chelsea Eastman; Bruchim, Revital; Kundi, Michael; Merletti, Franco; Vermeulen, Roel; Kromhout, Hans; Lee, Ae-Kyoung; Maslanyj, Myron; Sim, Malcolm R.; Taki, Masao; Wiart, Joe; Armstrong, Bruce; Milne, Elizabeth; Benke, Geza; Schattner, Rosa; Hutter, Hans-Peter; Woehrer, Adelheid; Krewski, Daniel; Mohipp, Charmaine; Momoli, Franco; Ritvo, Paul; Spinelli, John; Lacour, Brigitte; Delmas, Dominique; Remen, Thomas; Radon, Katja; Weinmann, Tobias; Klostermann, Swaantje; Heinrich, Sabine; Petridou, Eleni; Bouka, Evdoxia; Panagopoulou, Paraskevi; Dikshit, Rajesh; Nagrani, Rajini; Even-Nir, Hadas; Chetrit, Angela; Maule, Milena; Migliore, Enrica; Filippini, Graziella; Miligi, Lucia; Mattioli, Stefano; Yamaguchi, Naohito; Kojimahara, Noriko; Ha, Mina; Choi, Kyung-Hwa; Mannetje, Andrea ’t; Eng, Amanda; Woodward, Alistair; Carretero, Gema; Alguacil, Juan; Aragones, Nuria; Suare-Varela, Maria Morales; Goedhart, Geertje; Schouten-van Meeteren, A. Antoinette Y. N.; Reedijk, A. Ardine M. J.; Cardis, Elisabeth

    2014-01-01

    The rapid increase in mobile phone use in young people has generated concern about possible health effects of exposure to radiofrequency (RF) and extremely low frequency (ELF) electromagnetic fields (EMF). MOBI-Kids, a multinational case–control study, investigates the potential effects of childhood and adolescent exposure to EMF from mobile communications technologies on brain tumor risk in 14 countries. The study, which aims to include approximately 1,000 brain tumor cases aged 10–24 years and two individually matched controls for each case, follows a common protocol and builds upon the methodological experience of the INTERPHONE study. The design and conduct of a study on EMF exposure and brain tumor risk in young people in a large number of countries is complex and poses methodological challenges. This manuscript discusses the design of MOBI-Kids and describes the challenges and approaches chosen to address them, including: (1) the choice of controls operated for suspected appendicitis, to reduce potential selection bias related to low response rates among population controls; (2) investigating a young study population spanning a relatively wide age range; (3) conducting a large, multinational epidemiological study, while adhering to increasingly stricter ethics requirements; (4) investigating a rare and potentially fatal disease; and (5) assessing exposure to EMF from communication technologies. Our experience in thus far developing and implementing the study protocol indicates that MOBI-Kids is feasible and will generate results that will contribute to the understanding of potential brain tumor risks associated with use of mobile phones and other wireless communications technologies among young people. PMID:25295243

  12. The MOBI-Kids study protocol: challenges in assessing childhood and adolescent exposure to electromagnetic fields from wireless telecommunication technologies and possible association with brain tumor risk

    Directory of Open Access Journals (Sweden)

    Siegal eSadetzki

    2014-09-01

    Full Text Available The rapid increase in mobile phone use in young people has generated concern about possible health effects of exposure to radiofrequency (RF, extremely low frequency (ELF electromagnetic fields (EMF. MOBI-Kids, a multinational case-control study, investigates the potential effects of childhood and adolescent exposure to EMF from mobile communications technologies on brain tumor risk in 14 countries. The study, which aims to include approximately 1,000 brain tumor cases aged 10-24 years and two individually matched controls for each case, follows a common protocol and builds upon the methodological experience of the INTERPHONE study. The design and conduct of a study on EMF exposure and brain tumor risk in young people in a large number of countries is complex and poses methodological challenges. This manuscript discusses the design of MOBI-Kids and describes the challenges and approaches chosen to address them, including: 1 the choice of controls operated for suspected appendicitis, to reduce potential selection bias related to low response rates among population controls; 2 investigating a young study population spanning a relatively wide age-range. 3 conducting a large, multinational epidemiological study, while adhering to increasingly stricter ethics requirements; 4 investigating a rare and potentially fatal disease; and 5 assessing exposure to EMF from communication technologies. Our experience thus far developing and implementing the study protocol indicates that MOBI-Kids is feasible and will generate results that will contribute to the understanding of potential brain tumor risks associated with use of mobile phones and other wireless communications technologies among young people.

  13. Electromagnetic compatibility for the control and command equipments in nuclear power plants

    International Nuclear Information System (INIS)

    Buisson, J.

    1985-06-01

    Different kinds of electrical interference produce some disturbance on electronic sub-assemblies used to assume the control and the command of nuclear reactors. Following interferences are described: power supply lines perturbations, potential difference between grounding connections, electromagnetic fields. A method is described for testing the EMC of different equipments. The advantages of this method are: no destructive method, usable for testing equipment ''in situ'' in operating conditions on nuclear power plant, usable for testing equipment before operating conditions (acceptance test), level of the testing signals similar to the electrical interference level induced by the electromagnetic environment in normal operating conditions, no particular equipment and installation for test are required [fr

  14. Electromagnetic Interface Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Electromagnetic Interface Testing facilitysupports such testing asEmissions, Field Strength, Mode Stirring, EMP Pulser, 4 Probe Monitoring/Leveling System, and...

  15. Protecting the Power Grid From Electromagnetic Pulses

    Science.gov (United States)

    Simpson, Sarah

    2004-10-01

    A nuclear explosion high in the Earth's atmosphere does no immediate known harm to living things, but the resulting electromagnetic pulse (EMP) from a single detonation could degrade 70 percent or more of the country's electrical service in an instant, warns the Commission to Assess the Threat to the United States from Electromagnetic Pulse Attack, which presented its findings to the U.S. Congress in July.

  16. Acoustic transparency and opacity using Fano Interferences in Metamaterials

    KAUST Repository

    Khelif, A.

    2015-08-04

    We investigate both experimentally and theoretically how to generate the acoustical analogue of the Electromagnetically Induced Transparency. This phenomenon arises from Fano resonances originating from constructive and destructive interferences of a narrow discrete resonance with a broad spectral line or continuum. Measurements were realized on a double-cavity structure by using a Kundt’s Tube. Transmission properties reveal an asymmetric lineshape of the transmission that leads to acoustic transparency.

  17. Laser Interference Lithography

    NARCIS (Netherlands)

    van Wolferen, Hendricus A.G.M.; Abelmann, Leon; Hennessy, Theodore C.

    In this chapter we explain how submicron gratings can be prepared by Laser Interference Lithography (LIL). In this maskless lithography technique, the standing wave pattern that exists at the intersection of two coherent laser beams is used to expose a photosensitive layer. We show how to build the

  18. Kvantová interference

    Czech Academy of Sciences Publication Activity Database

    Peřina, Jan

    2003-01-01

    Roč. 48, č. 4 (2003), s. 99-103 ISSN 0447-6441 R&D Projects: GA MŠk LN00A015 Institutional research plan: CEZ:AV0Z1010921 Keywords : interference * quantum cryptography * quantum computing * quantum teleportation Subject RIV: BH - Optics, Masers, Lasers

  19. Possible health hazards for cardiac pacemaker wearers from exposure to electromagnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    1988-03-01

    Cardiac pacemakers are used to provide electrical stimulation to the heart when the heart's natural rhythm is interrupted. This study shows that they can be susceptible to electromagnetic fields. Pacemakers are well protected against common electromagnetic fields, such as those from household appliances. But intense electomagnetic fields, such as those found in some industrial settings, could affect the functioning of the pacemaker. Such interference may cause the pacemaker wearer to feel dizzy or experience an accelerated heartbeat. While this is not fatal, the pacemaker wearer should try to move away from the source of the interfering field and avoid situations in which interference could arise. After experiencing any of these symptoms, the pacemaker wearer should contact a physician. Potential sources of electromagnetic interference should be identified and characterized to determine if there could be an interference hazard. Exposure to interfering electomagnetic fields should be minimized. 7 refs., 1 fig.

  20. Assessment of the fears of the public concerning possible hazards from HF electromagnetic fields of mobile phone equipment - annual enquiries. Final report on the enquiry of 2005

    International Nuclear Information System (INIS)

    Belz, Janina

    2007-01-01

    The BfS (Bundesamt fuer Strahlenschutz, Federal Radiation Protection Office) carries out a continuous series of investigations on citizens' fears concerning the potential hazards of HF electromagnetic fields emitted by mobile phones (''Ermittlung der Befuerchtungen und Aengste der breiten Oeffentlichkeit hinsichtlich moeglicher Gefahren der hochfrequenten elektromagnetischen Felder des Mobilfunks''). For this purpose, enquiries by telephone were carried out annually between 2003 and 2006 among representative parts of the population by the Institut fuer angewandte Sozialwissenschaft. These are to investigate the awareness of the population of health risks of electromagnetic fields and also show changes in awareness over the period under investigation. (orig.) [de

  1. Teaching Electromagnetic Waves in College Physics Laboratory

    Science.gov (United States)

    Kezerashvili, Roman Y.; Leng, L.

    2006-12-01

    One of the important educational advantages of the simultaneous study of the electromagnetic waves and light is to show that light and the electromagnetic radiation have the same properties so that the students can visualize the properties of the electromagnetic radiation through observation of light propagation. In our approach we are suggest to study the properties of a microwave radiation and light in parallel. The following experiments can be easily designed and they provide a methodical introduction to electromagnetic theory using the microwave radiation and light: the study of the inverse square law of the dependence of the intensity of radiation (microwave and light) on the distance, the law of reflection and refraction, investigation of the phenomenon of polarization and how a polarizer can be used to alter the polarization of microwave radiation and light, measuring the Brewster's angle, studying interference by performing double-slit experiment for microwave radiation and light. Finally students measure the wavelength of the laser light and microwave radiation using the corresponding versions the Michelson’s interferometer, and recognize that these two radiations only differ by the wavelength or frequency.

  2. Codebook-based interference alignment for uplink MIMO interference channels

    KAUST Repository

    Lee, Hyun Ho; Park, Kihong; Ko, Youngchai; Alouini, Mohamed-Slim

    2014-01-01

    In this paper, we propose a codebook-based interference alignment (IA) scheme in the constant multiple-input multipleoutput (MIMO) interference channel especially for the uplink scenario. In our proposed scheme, we assume cooperation among base

  3. Ionization in a quantized electromagnetic field

    International Nuclear Information System (INIS)

    Gonoskov, I. A.; Vugalter, G. A.; Mironov, V. A.

    2007-01-01

    An analytical expression for a matrix element of the transition from a bound state of an electron in an atom to continuum states is obtained by solving the problem of interaction of the electron with a quantized electromagnetic field. This expression is used to derive formulas for the photoelectron spectrum and the rate of ionization of the simplest model atomic system upon absorption of an arbitrary number of photons. The expressions derived are analyzed and compared with the corresponding relationships obtained via other approaches. It is demonstrated that there are differences as compared to the case of the classical field. In particular, the photoelectron spectrum exhibits dips due to the destructive interference of the transition amplitudes in the quantized electromagnetic field

  4. An Electromagnetic Beam Converter

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an electromagnetic beam converter and a method for conversion of an input beam of electromagnetic radiation having a bell shaped intensity profile a(x,y) into an output beam having a prescribed target intensity profile l(x',y') based on a further development...

  5. Classical electromagnetic radiation

    CERN Document Server

    Heald, Mark A

    2012-01-01

    Newly corrected, this highly acclaimed text is suitable for advanced physics courses. The author presents a very accessible macroscopic view of classical electromagnetics that emphasizes integrating electromagnetic theory with physical optics. The survey follows the historical development of physics, culminating in the use of four-vector relativity to fully integrate electricity with magnetism.

  6. High frequency electromagnetic dosimetry

    CERN Document Server

    Sánchez-Hernández, David A

    2009-01-01

    Along with the growth of RF and microwave technology applications, there is a mounting concern about the possible adverse effects over human health from electromagnetic radiation. Addressing this issue and putting it into perspective, this groundbreaking resource provides critical details on the latest advances in high frequency electromagnetic dosimetry.

  7. Electromagnetically Operated Counter

    Science.gov (United States)

    Goldberg, H D; Goldberg, M I

    1951-12-18

    An electromagnetically operated counter wherein signals to be counted are applied to cause stepwise rotation of a rotatable element which is connected to a suitable register. The mechanism involved consists of a rotatable armature having three spaced cores of magnetic material and a pair of diametrically opposed electromagnets with a suitable pulsing circuit to actuate the magnets.

  8. Electromagnetic cyclotron harmonic waves

    International Nuclear Information System (INIS)

    Ohnuma, T.; Watanabe, T.; Hamamatsu, K.

    1981-09-01

    Electromagnetic electron cyclotron harmonic waves just below the electron cyclotron harmonics are investigated numerically and experimentally. Backward waves which are observed to propagate nearly perpendicular to the magnetic field just below the electron cyclotron frequency in a high density magnetoplasma are confirmed to be in accord with the theoretical electromagnetic cyclotron waves. (author)

  9. Impact of total ionizing dose on the electromagnetic susceptibility of a single bipolar transistor

    International Nuclear Information System (INIS)

    Doridant, A.; Jarrix, S.; Raoult, J.; Blain, A.; Dusseau, L.; Chatry, N.; Calvel, P.; Hoffmann, P.

    2012-01-01

    Space or military electronic components are subject to both electromagnetic fields and total ionizing dose. This paper deals with the electromagnetic susceptibility of a discrete low frequency transistor subject to total ionizing dose deposition. The electromagnetic susceptibility is investigated on both non-irradiated and irradiated transistors mounted in common emitter configuration. The change in susceptibility to 100 MHz-1.5 GHz interferences lights up a synergy effect between near field electromagnetic waves and total ionizing dose. Physical mechanisms leading to changes in signal output are detailed. (authors)

  10. Assessments and Viewpoints on the Biological and Human Health Effects of Extremely Low Frequency (ELF) Electromagnetic Fields. Compilation of Commissioned Papers for the ELF Literature Review Project.

    Science.gov (United States)

    1985-05-01

    E. Johnson. 1981. The effect of electromagnetic fields on alkaline phosphatase in clonal osteoblastic osteosarcoma cells. Rogers, L. E., J. L. Warren...F. von Recum, and J. B. Park. 1979. Effect of electrical stimulation of canine skin, and percutaneous device-skin interface healing. In Electrical

  11. Requirements and analysis of electromagnetic compatibility of safety-related instrumentation and control system in nuclear power plants

    International Nuclear Information System (INIS)

    Liu Sujuan

    2002-01-01

    The state-of-the-art instrumentation and control system and the influence of their application to the electromagnetic compatibility is analyzed. Based on the present situation of nuclear safety in China and relevant experiences from other countries, the author tries to probe into the requirements and test methods about how safety-related instrument and control system to accommodate electromagnetic interference, radio-frequency interference and power surges in the environments of nuclear power plant so as to develop Chinese safety standards

  12. Patient examinations using electrical impedance tomography—sources of interference in the intensive care unit

    International Nuclear Information System (INIS)

    Frerichs, Inéz; Pulletz, Sven; Elke, Gunnar; Gawelczyk, Barbara; Frerichs, Alexander; Weiler, Norbert

    2011-01-01

    Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to demonstrate how some medical nursing and monitoring devices interfere with EIT measurements and modify the EIT scans and waveforms, which approaches can be applied to minimize these effects and how possible misinterpretation can be avoided. We present four cases of EIT examinations of adult ICU patients. Two of the patients were subjected to pulsation therapy using a pulsating air suspension mattress while being ventilated by high-frequency oscillatory or conventional pressure-controlled ventilation, respectively. The EIT signal modulation synchronous with the occurrence of the pulsating wave was 2.3 times larger than the periodic modulation synchronous with heart rate and high-frequency oscillations. During conventional ventilation, the pulsating mattress induced an EIT signal fluctuation with a magnitude corresponding to about 20% of the patient's tidal volume. In the third patient, interference with EIT examination was caused by continuous cardiac output monitoring. The last patient's examination was disturbed by impedance pneumography when excitation currents of similar frequency to EIT were used. In all subjects, the generation of functional EIT scans was compromised and interpretation of regional ventilation impossible. Discontinuation of pulsation therapy and of continuous cardiac output and impedance respiration monitoring immediately improved the EIT signal and scan quality. Offline processing of the disturbed data using frequency filtering enabled partial retrieval of relevant information. We conclude that thoracic EIT examinations in the ICU require cautious interpretation because of possible mechanical and electromagnetic

  13. Interference coupling analysis based on a hybrid method: application to a radio telescope system

    Science.gov (United States)

    Xu, Qing-Lin; Qiu, Yang; Tian, Jin; Liu, Qi

    2018-02-01

    Working in a way that passively receives electromagnetic radiation from a celestial body, a radio telescope can be easily disturbed by external radio frequency interference as well as electromagnetic interference generated by electric and electronic components operating at the telescope site. A quantitative analysis of these interferences must be taken into account carefully for further electromagnetic protection of the radio telescope. In this paper, based on electromagnetic topology theory, a hybrid method that combines the Baum-Liu-Tesche (BLT) equation and transfer function is proposed. In this method, the coupling path of the radio telescope is divided into strong coupling and weak coupling sub-paths, and the coupling intensity criterion is proposed by analyzing the conditions in which the BLT equation simplifies to a transfer function. According to the coupling intensity criterion, the topological model of a typical radio telescope system is established. The proposed method is used to solve the interference response of the radio telescope system by analyzing subsystems with different coupling modes separately and then integrating the responses of the subsystems as the response of the entire system. The validity of the proposed method is verified numerically. The results indicate that the proposed method, compared with the direct solving method, reduces the difficulty and improves the efficiency of interference prediction.

  14. Grounding and shielding circuits and interference

    CERN Document Server

    Morrison, Ralph

    2016-01-01

    Applies basic field behavior in circuit design and demonstrates how it relates to grounding and shielding requirements and techniques in circuit design This book connects the fundamentals of electromagnetic theory to the problems of interference in all types of electronic design. The text covers power distribution in facilities, mixing of analog and digital circuitry, circuit board layout at high clock rates, and meeting radiation and susceptibility standards. The author examines the grounding and shielding requirements and techniques in circuit design and applies basic physics to circuit behavior. The sixth edition of this book has been updated with new material added throughout the chapters where appropriate. The presentation of the book has also been rearranged in order to reflect the current trends in the field.

  15. Electromagnetic shaft seal

    International Nuclear Information System (INIS)

    Takahashi, Kenji.

    1994-01-01

    As an electromagnetic shaft seal, there are disposed outwarding electromagnetic induction devices having generating power directing to an electroconductive fluid as an object of sealing, and inwarding electromagnetic induction device added coaxially. There are disposed elongate rectangular looped first coils having a predetermined inner diameter, second coils having the same shape and shifted by a predetermined pitch relative to the first coil and third coil having the same shape and shifted by a predetermined pitch relative to the second coil respectively each at a predetermined inner diameter of clearance to the outwarding electromagnetic induction devices and the inwarding electromagnetic induction device. If the inwarding electromagnetic induction device and the outwarding electromagnetic induction device are operated, they are stopped at a point that the generating power of the former is equal with the sum of the generating power of the latter and a differential pressure. When three-phase AC is charged to the first coil, the second coil and the third coil successively, a force is generated in the advancing direction of the magnetic field in the electroconductive fluid by the similar effect to that of a linear motor, and the seal is maintained at high reliability. Moreover, the limit for the rotational angle of the shaft is not caused. (N.H.)

  16. Evaluation of uncertainty in the measurement of environmental electromagnetic fields

    International Nuclear Information System (INIS)

    Vulevic, B.; Osmokrovic, P.

    2010-01-01

    With regard to Non-ionising radiation protection, the relationship between human exposure to electromagnetic fields and health is controversial. Electromagnetic fields have become omnipresent in the daily environment. This paper assesses the problem of how to compare a measurement result with a limit fixed by the standard for human exposure to electric, magnetic and electromagnetic fields (0 Hz-300 GHz). The purpose of the paper is an appropriate representation of the basic information about evaluation of measurement uncertainty. (authors)

  17. Understanding interference experiments with polarized light through photon trajectories

    International Nuclear Information System (INIS)

    Sanz, A.S.; Davidovic, M.; Bozic, M.; Miret-Artes, S.

    2010-01-01

    Bohmian mechanics allows to visualize and understand the quantum-mechanical behavior of massive particles in terms of trajectories. As shown by Bialynicki-Birula, Electromagnetism also admits a hydrodynamical formulation when the existence of a wave function for photons (properly defined) is assumed. This formulation thus provides an alternative interpretation of optical phenomena in terms of photon trajectories, whose flow yields a pictorial view of the evolution of the electromagnetic energy density in configuration space. This trajectory-based theoretical framework is considered here to study and analyze the outcome from Young-type diffraction experiments within the context of the Arago-Fresnel laws. More specifically, photon trajectories in the region behind the two slits are obtained in the case where the slits are illuminated by a polarized monochromatic plane wave. Expressions to determine electromagnetic energy flow lines and photon trajectories within this scenario are provided, as well as a procedure to compute them in the particular case of gratings totally transparent inside the slits and completely absorbing outside them. As is shown, the electromagnetic energy flow lines obtained allow to monitor at each point of space the behavior of the electromagnetic energy flow and, therefore, to evaluate the effects caused on it by the presence (right behind each slit) of polarizers with the same or different polarization axes. This leads to a trajectory-based picture of the Arago-Fresnel laws for the interference of polarized light.

  18. Curved electromagnetic missiles

    International Nuclear Information System (INIS)

    Myers, J.M.; Shen, H.M.; Wu, T.T.

    1989-01-01

    Transient electromagnetic fields can exhibit interesting behavior in the limit of great distances from their sources. In situations of finite total radiated energy, the energy reaching a distant receiver can decrease with distance much more slowly than the usual r - 2 . Cases of such slow decrease have been referred to as electromagnetic missiles. All of the wide variety of known missiles propagate in essentially straight lines. A sketch is presented here of a missile that can follow a path that is strongly curved. An example of a curved electromagnetic missile is explicitly constructed and some of its properties are discussed. References to details available elsewhere are given

  19. Electromagnetic spatial coherence wavelets

    International Nuclear Information System (INIS)

    Castaneda, R.; Garcia-Sucerquia, J.

    2005-10-01

    The recently introduced concept of spatial coherence wavelets is generalized for describing the propagation of electromagnetic fields in the free space. For this aim, the spatial coherence wavelet tensor is introduced as an elementary amount, in terms of which the formerly known quantities for this domain can be expressed. It allows analyzing the relationship between the spatial coherence properties and the polarization state of the electromagnetic wave. This approach is completely consistent with the recently introduced unified theory of coherence and polarization for random electromagnetic beams, but it provides a further insight about the causal relationship between the polarization states at different planes along the propagation path. (author)

  20. Nonlinear surface electromagnetic phenomena

    CERN Document Server

    Ponath, H-E

    1991-01-01

    In recent years the physics of electromagnetic surface phenomena has developed rapidly, evolving into technologies for communications and industry, such as fiber and integrated optics. The variety of phenomena based on electromagnetism at surfaces is rich and this book was written with the aim of summarizing the available knowledge in selected areas of the field. The book contains reviews written by solid state and optical physicists on the nonlinear interaction of electromagnetic waves at and with surfaces and films. Both the physical phenomena and some potential applications are

  1. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  2. Statistical electromagnetics: Complex cavities

    NARCIS (Netherlands)

    Naus, H.W.L.

    2008-01-01

    A selection of the literature on the statistical description of electromagnetic fields and complex cavities is concisely reviewed. Some essential concepts, for example, the application of the central limit theorem and the maximum entropy principle, are scrutinized. Implicit assumptions, biased

  3. Broadband Electromagnetic Technology

    Science.gov (United States)

    2011-06-23

    The objectives of this project are to continue the enhancements to the combined Broadband Electromagnetic and Full Encirclement Unit (BEM-FEU) technologies and to evaluate the systems capability in the laboratory and the field. The BEM instrument ...

  4. Magnetorheological suspension electromagnetic brake

    International Nuclear Information System (INIS)

    Bica, Ioan

    2004-01-01

    The magnetorheological suspension (MRS) brake is of the monoblock type. The main part of the electromagnetic brake is an electromagnet, between whose poles two MRS disks are placed. For distances between disks of 0.65x10 -3 m±10%, revolutions of the electric motor, coupled to the electromagnetic brake, ranging between 200 and 1600 rev/min and braking powers of up to 85 W, there are no differences in revolutions between the disks of the electromagnetic brake. For fixed revolutions of the electric motor, the revolution of the parallel disk can be modified continuously by means of the intensity of the magnetic field. In all cases, the quantity of MRS is of 0.35x10 -3 kg

  5. Computational electromagnetic-aerodynamics

    CERN Document Server

    Shang, Joseph J S

    2016-01-01

    Presents numerical algorithms, procedures, and techniques required to solve engineering problems relating to the interactions between electromagnetic fields, fluid flow, and interdisciplinary technology for aerodynamics, electromagnetics, chemical-physics kinetics, and plasmadynamics This book addresses modeling and simulation science and technology for studying ionized gas phenomena in engineering applications. Computational Electromagnetic-Aerodynamics is organized into ten chapters. Chapter one to three introduce the fundamental concepts of plasmadynamics, chemical-physics of ionization, classical magnetohydrodynamics, and their extensions to plasma-based flow control actuators, high-speed flows of interplanetary re-entry, and ion thrusters in space exploration. Chapter four to six explain numerical algorithms and procedures for solving Maxwell’s equation in the time domain for computational electromagnetics, plasma wave propagation, and the time-dependent c mpressible Navier-Stokes equation for aerodyn...

  6. OPAL detector electromagnetic calorimeter

    CERN Multimedia

    1988-01-01

    Half of the electromagnetic calorimeter of the OPAL detector is seen in this photo. This calorimeter consists of 4720 blocks of lead glass. It was used to detect and measure the energy of photons, electrons and positrons by absorbing them.

  7. The classical electromagnetic field

    CERN Document Server

    Eyges, Leonard

    2010-01-01

    This excellent text covers a year's course in advanced theoretical electromagnetism, first introducing theory, then its application. Topics include vectors D and H inside matter, conservation laws for energy, momentum, invariance, form invariance, covariance in special relativity, and more.

  8. Mathematics and electromagnetism

    International Nuclear Information System (INIS)

    Rodriguez Danta, M.

    2000-01-01

    Symbiosis between mathematics and electromagnetism is analyzed in a simple and concise manner by taking a historical perspective. The universal tool character of mathematical models allowed the transfer of models from several branches of physics into the realm of electromagnetism by drawing analogies. The mutual interdependence between covariant formulation and tensor calculus is marked. The paper focuses on the guiding idea of field theory and Maxwell's equations. Likewise, geometrization of interactions in connection with gauge fields is also noted. (Author)

  9. The ATLAS electromagnetic calorimeter

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Michel Mathieu, a technician for the ATLAS collaboration, is cabling the ATLAS electromagnetic calorimeter's first end-cap, before insertion into its cryostat. Millions of wires are connected to the electromagnetic calorimeter on this end-cap that must be carefully fed out from the detector so that data can be read out. Every element on the detector will be attached to one of these wires so that a full digital map of the end-cap can be recreated.

  10. Electromagnetic Fields Exposure Limits

    Science.gov (United States)

    2018-01-01

    Mr. T.P. (Tjerk) KUIPERS Senior Adviser Health Physics Military Healthcare & Occupational Health Expertise Co-ordination Centre Support...Test of Biological Integrity in Dogs Exposed to an Electromagnetic Pulse Environment”, Health Physics 36:159-165, 1979. [11] Baum, S.J., Ekstrom, M.E...Electromagnetic Radiation”, Health Physics 30:161-166, 1976. [12] Baum, S., Skidmore, W. and Ekstrom, M., “Continuous Exposure of Rodents to 108 Pulses

  11. Electromagnetic Manifestation of Earthquakes

    OpenAIRE

    Uvarov Vladimir

    2017-01-01

    In a joint analysis of the results of recording the electrical component of the natural electromagnetic field of the Earth and the catalog of earthquakes in Kamchatka in 2013, unipolar pulses of constant amplitude associated with earthquakes were identified, whose activity is closely correlated with the energy of the electromagnetic field. For the explanation, a hypothesis about the cooperative character of these impulses is proposed.

  12. Electromagnetic Manifestation of Earthquakes

    Directory of Open Access Journals (Sweden)

    Uvarov Vladimir

    2017-01-01

    Full Text Available In a joint analysis of the results of recording the electrical component of the natural electromagnetic field of the Earth and the catalog of earthquakes in Kamchatka in 2013, unipolar pulses of constant amplitude associated with earthquakes were identified, whose activity is closely correlated with the energy of the electromagnetic field. For the explanation, a hypothesis about the cooperative character of these impulses is proposed.

  13. Electromagnetic reverberation chambers

    CERN Document Server

    Besnier, Philippe

    2013-01-01

    Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc

  14. MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system

    Science.gov (United States)

    Omidvari, Negar; Topping, Geoffrey; Cabello, Jorge; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.

    2018-05-01

    Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out crystals with high-gain silicon photomultipliers (SiPMs) were studied with a small animal PET insert for a 7 T MRI system, in which the SiPM charge was transferred to outside the MRI scanner using coaxial cables. The interferences between the two systems were studied with three radio-frequency (RF) coil configurations. The effects of PET on the static magnetic field, flip angle distribution, RF noise, and image quality of various MRI sequences (gradient echo, spin echo, and echo planar imaging (EPI) at 1H frequency, and chemical shift imaging at 13C frequency) were investigated. The effects of fast-switching gradient fields and RF pulses on PET count rate were studied, while the PET insert and the readout electronics were not shielded. Operating the insert inside a 1H volume coil, used for RF transmission and reception, limited the MRI to T1-weighted imaging, due to coil detuning and RF attenuation, and resulted in significant PET count loss. Using a surface receive coil allowed all tested MR sequences to be used with the insert, with 45–59% signal-to-noise ratio (SNR) degradation, compared to without PET. With a 1H/13C volume coil inside the insert and shielded by a copper tube, the SNR degradation was limited to 23–30% with all tested sequences. The insert did not introduce any discernible distortions into images of two tested EPI sequences. Use of truncated sinc shaped RF excitation pulses and gradient field switching had negligible effects on PET count rate. However, PET count rate was substantially affected by high-power RF block pulses and temperature variations due to high gradient duty cycles.

  15. Goats Don't Wear Coats: An Examination of Semantic Interference in Rhyming Assessments of Reading Readiness for English Language Learners

    Science.gov (United States)

    Moreira, Sylvia; Hamilton, Maryellen

    2006-01-01

    Rhyming tests have historically been used in the education system to assess reading readiness. English language learners (ELLs) have consistently scored poorly on these assessment tools. The current article examines a possible reason for this poor performance by ELLs. Specifically, the authors examined the relationship between semantic…

  16. The intention interference effect.

    Science.gov (United States)

    Cohen, Anna-Lisa; Kantner, Justin; Dixon, Roger A; Lindsay, D Stephen

    2011-01-01

    Intentions have been shown to be more accessible (e.g., more quickly and accurately recalled) compared to other sorts of to-be-remembered information; a result termed an intention superiority effect (Goschke & Kuhl, 1993). In the current study, we demonstrate an intention interference effect (IIE) in which color-naming performance in a Stroop task was slower for words belonging to an intention that participants had to remember to carry out (Do-the-Task condition) versus an intention that did not have to be executed (Ignore-the-Task condition). In previous work (e.g., Cohen et al., 2005), having a prospective intention in mind was confounded with carrying a memory load. In Experiment 1, we added a digit-retention task to control for effects of cognitive load. In Experiment 2, we eliminated the memory confound in a new way, by comparing intention-related and control words within each trial. Results from both Experiments 1 and 2 revealed an IIE suggesting that interference is very specific to the intention, not just to a memory load.

  17. Electromagnetic processes and interactions

    International Nuclear Information System (INIS)

    Scheck, F.

    1983-01-01

    The electron and muon are important tools in testing the structure of the fundamental electromagnetic interactions. On the other hand, if these interactions are known, they serve as ideal probes for the internal structure of complex hadronic targets such as nucleons and nuclei. Purely electromagnetic interactions play a distinctive role, for obvious experimental reasons: At low and intermediate energies the effective electromagnetic coupling is larger by many orders of magnitude than the weak couplings, so that electromagnetic processes are measurable to much higher accuracy than purely weak processes. The present chapter deals primarily with applications of charged leptons to problems of nucleon and nuclear structure, and to selected precision tests of quantum electrodynamics (QED) at low momentum transfers. In most of these applications the electromagnetic interactions effectively appear in the form of external fields in the leptonic particle's Dirac equation. This is the domain where the physics of (electromagnetically) interacting leptons can still be described in the framework of an effective, though relativistic, single particle theory. (orig.)

  18. Covariant electromagnetic field lines

    Science.gov (United States)

    Hadad, Y.; Cohen, E.; Kaminer, I.; Elitzur, A. C.

    2017-08-01

    Faraday introduced electric field lines as a powerful tool for understanding the electric force, and these field lines are still used today in classrooms and textbooks teaching the basics of electromagnetism within the electrostatic limit. However, despite attempts at generalizing this concept beyond the electrostatic limit, such a fully relativistic field line theory still appears to be missing. In this work, we propose such a theory and define covariant electromagnetic field lines that naturally extend electric field lines to relativistic systems and general electromagnetic fields. We derive a closed-form formula for the field lines curvature in the vicinity of a charge, and show that it is related to the world line of the charge. This demonstrates how the kinematics of a charge can be derived from the geometry of the electromagnetic field lines. Such a theory may also provide new tools in modeling and analyzing electromagnetic phenomena, and may entail new insights regarding long-standing problems such as radiation-reaction and self-force. In particular, the electromagnetic field lines curvature has the attractive property of being non-singular everywhere, thus eliminating all self-field singularities without using renormalization techniques.

  19. Electromagnetic cellular interactions.

    Science.gov (United States)

    Cifra, Michal; Fields, Jeremy Z; Farhadi, Ashkan

    2011-05-01

    Chemical and electrical interaction within and between cells is well established. Just the opposite is true about cellular interactions via other physical fields. The most probable candidate for an other form of cellular interaction is the electromagnetic field. We review theories and experiments on how cells can generate and detect electromagnetic fields generally, and if the cell-generated electromagnetic field can mediate cellular interactions. We do not limit here ourselves to specialized electro-excitable cells. Rather we describe physical processes that are of a more general nature and probably present in almost every type of living cell. The spectral range included is broad; from kHz to the visible part of the electromagnetic spectrum. We show that there is a rather large number of theories on how cells can generate and detect electromagnetic fields and discuss experimental evidence on electromagnetic cellular interactions in the modern scientific literature. Although small, it is continuously accumulating. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. On the exhaust of electromagnetic drive

    Directory of Open Access Journals (Sweden)

    Patrick Grahn

    2016-06-01

    Full Text Available Recent reports about propulsion without reaction mass have been met on one hand with enthusiasm and on the other hand with some doubts. Namely, closed metal cavities, when fueled with microwaves, have delivered thrust that could eventually maintain satellites on orbits using solar power. However, the measured thrust appears to be without any apparent exhaust. Thus the Law of Action-Reaction seems to have been violated. We consider the possibility that the exhaust is in a form that has so far escaped both experimental detection and theoretical attention. In the thruster’s cavity microwaves interfere with each other and invariably some photons will also end up co-propagating with opposite phases. At the destructive interference electromagnetic fields cancel. However, the photons themselves do not vanish for nothing but continue in propagation. These photon pairs without net electromagnetic field do not reflect back from the metal walls but escape from the resonator. By this action momentum is lost from the cavity which, according to the conservation of momentum, gives rise to an equal and opposite reaction. We examine theoretical corollaries and practical concerns that follow from the paired-photon conclusion.

  1. Beamforming design with proactive interference cancelation in MISO interference channels

    Science.gov (United States)

    Li, Yang; Tian, Yafei; Yang, Chenyang

    2015-12-01

    In this paper, we design coordinated beamforming at base stations (BSs) to facilitate interference cancelation at users in interference networks, where each BS is equipped with multiple antennas and each user is with a single antenna. By assuming that each user can select the best decoding strategy to mitigate the interference, either canceling the interference after decoding when it is strong or treating it as noise when it is weak, we optimize the beamforming vectors that maximize the sum rate for the networks under different interference scenarios and find the solutions of beamforming with closed-form expressions. The inherent design principles are then analyzed, and the performance gain over passive interference cancelation is demonstrated through simulations in heterogeneous cellular networks.

  2. [Trail walking test for assessment of motor cognitive interference in older adults. Development and evaluation of the psychometric properties of the procedure].

    Science.gov (United States)

    Schott, Nadja

    2015-12-01

    falls and 91.6 % of cases were correctly classified. The results indicate that high-level cognitive processes interfere with automatic processes such as walking. The TWT which converts a relevant fall risk-associated standard neuropsychological test (TMT) with increasing cognitive load into a mobility task, was shown to be a feasible, reliable and valid tool for older adults to discriminate between non-fallers and fallers.

  3. Measurement technology of RF interference current in high current system

    Science.gov (United States)

    Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei

    2018-06-01

    Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.

  4. The Impact of Radio Interference on Future Radio Telescopes

    Science.gov (United States)

    Mitchell, Daniel A.; Robertson, Gordon J.; Sault, Robert J.

    While future radio telescopes will require technological advances from the communications industry interference from sources such as satellites and mobile phones is a serious concern. In addition to the fact that the level of interference is growing constantly the increased capabilities of next generation instruments make them more prone to harmful interference. These facilities must have mechanisms to allow operation in a crowded spectrum. In this report some of the factors which may limit the effectiveness of these mechanisms are investigated. Radio astronomy is unique among other observing wavelengths in that the radiation can be fully sampled at a rate which completely specifies the electromagnetic environment. Knowledge of phases and antennae gain factors affords one the opportunity to attempt to mitigate interference from the astronomical data. At present several interference mitigation techniques have been demonstrated to be extremely effective. However the observational scales of the new facilities will push the techniques to their limits. Processes such as signal decorrelation varying antenna gain and instabilities in the primary beam will have a serious effect on some of the algorithms. In addition the sheer volume of data produced will render some techniques computationally and financially impossible.

  5. An investigation of the levels of electromagnetic radiation generated by wind turbines

    International Nuclear Information System (INIS)

    Morgan, C.A.

    1992-01-01

    The issue of electromagnetic interference is arising with some regularity as various wind energy projects throughout the UK reach the stage where local authority planning approval is sought. To many of the parties involved, wind turbines represent an unknown quantity and hence objections to their siting must be expected. Wind turbines may cause electromagnetic interference through two quite distinct processes. The first occurs when the wind turbine scatters electromagnetic signals passing through the area of the site and essentially, provides a second path between the transmitter and receiver of the signal. The second source of interference arises when signals generated within the wind turbine itself affect communications equipment or, indeed, any electronic circuitry. A case in point is a wind farm project under development by Bonython Estates of Cornwall. The aim of this project was to investigate the emissions from the wind turbines proposed for the Bonython development. This was achieved by means of field measurements on existing installations. (author)

  6. Multifunctional hybrids for electromagnetic absorption

    International Nuclear Information System (INIS)

    Huynen, I.; Quievy, N.; Bailly, C.; Bollen, P.; Detrembleur, C.; Eggermont, S.; Molenberg, I.; Thomassin, J.M.; Urbanczyk, L.

    2011-01-01

    Highlights: → EM absorption requires low dielectric constant and ∼1 S/m electrical conductivity. → New hybrids were processed with CNT-filled polymer foam inserted in Al honeycomb. → The EM absorption in the GHz range is superior to any known material. → A closed form model is used to guide the design of the hybrid. → The architectured material is light with potential for thermal management. - Abstract: Electromagnetic (EM) interferences are ubiquitous in modern technologies and impact on the reliability of electronic devices and on living cells. Shielding by EM absorption, which is preferable over reflection in certain instances, requires combining a low dielectric constant with high electrical conductivity, which are antagonist properties in the world of materials. A novel class of hybrid materials for EM absorption in the gigahertz range has been developed based on a hierarchical architecture involving a metallic honeycomb filled with a carbon nanotube-reinforced polymer foam. The waveguide characteristics of the honeycomb combined with the performance of the foam lead to unexpectedly large EM power absorption over a wide frequency range, superior to any known material. The peak absorption frequency can be tuned by varying the shape of the honeycomb unit cell. A closed form model of the EM reflection and absorption provides a tool for the optimization of the hybrid. This designed material sets the stage for a new class of sandwich panels combining high EM absorption with mass efficiency, stiffness and thermal management.

  7. Brief Introduction of Chinese National Technical Committee for Standardization on Radio Interference

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    @@ Chinese Nationa Technical Committee for Standardization on Radio Interference(SAC/TC79),ESTABLISHED IN 1986,is the national technical organization relating to different departments for standardization,with responsibility for technical research of electromagnetic compatibility as well as the management of each subcommittee.

  8. An Assessment of Hazards Caused by Electromagnetic Interaction on Humans Present near Short-Wave Physiotherapeutic Devices of Various Types Including Hazards for Users of Electronic Active Implantable Medical Devices (AIMD

    Directory of Open Access Journals (Sweden)

    Jolanta Karpowicz

    2013-01-01

    Full Text Available Leakage of electromagnetic fields (EMF from short-wave radiofrequency physiotherapeutic diathermies (SWDs may cause health and safety hazards affecting unintentionally exposed workers (W or general public (GP members (assisting patient exposed during treatment or presenting there for other reasons. Increasing use of electronic active implantable medical devices (AIMDs, by patients, attendants, and workers, needs attention because dysfunctions of these devices may be caused by electromagnetic interactions. EMF emitted by 12 SWDs (with capacitive or inductive applicators were assessed following international guidelines on protection against EMF exposure (International Commission on Nonionizing Radiation Protection for GP and W, new European directive 2013/35/EU for W, European Recommendation for GP, and European Standard EN 50527-1 for AIMD users. Direct EMF hazards for humans near inductive applicators were identified at a distance not exceeding 45 cm for W or 62 cm for GP, but for AIMD users up to 90 cm (twice longer than that for W and 50% longer than that for GP because EMF is pulsed modulated. Near capacitive applicators emitting continuous wave, the corresponding distances were: 120 cm for W or 150 cm for both—GP or AIMD users. This assessment does not cover patients who undergo SWD treatment (but it is usually recommended for AIMD users to be careful with EMF treatment.

  9. Graphene quantum interference photodetector

    Directory of Open Access Journals (Sweden)

    Mahbub Alam

    2015-03-01

    Full Text Available In this work, a graphene quantum interference (QI photodetector was simulated in two regimes of operation. The structure consists of a graphene nanoribbon, Mach–Zehnder interferometer (MZI, which exhibits a strongly resonant transmission of electrons of specific energies. In the first regime of operation (that of a linear photodetector, low intensity light couples two resonant energy levels, resulting in scattering and differential transmission of current with an external quantum efficiency of up to 5.2%. In the second regime of operation, full current switching is caused by the phase decoherence of the current due to a strong photon flux in one or both of the interferometer arms in the same MZI structure. Graphene QI photodetectors have several distinct advantages: they are of very small size, they do not require p- and n-doped regions, and they exhibit a high external quantum efficiency.

  10. Anomalous electromagnetic coupling via entanglement at the nanoscale

    International Nuclear Information System (INIS)

    Slepyan, Gregory; Boag, Amir; Mordachev, Vladimir; Sinkevich, Eugene; Maksimenko, Sergey; Kuzhir, Polina; Miano, Giovanni; Portnoi, Mikhail E; Maffucci, Antonio

    2017-01-01

    Understanding unwanted mutual interactions between devices at the nanoscale is crucial for the study of the electromagnetic compatibility in nanoelectronic and nanophotonic systems. Anomalous electromagnetic coupling (crosstalk) between nanodevices may arise from the combination of electromagnetic interaction and quantum entanglement. In this paper we study in detail the crosstalk between two identical nanodevices, each consisting of a quantum emitter (atom, quantum dot, etc), capacitively coupled to a pair of nanoelectrodes. Using the generalized susceptibility concept, the overall system is modeled as a two-port within the framework of the electrical circuit theory and it is characterized by the admittance matrix. We show that the entanglement changes dramatically the physical picture of the electromagnetic crosstalk. In particular, the excitation produced in one of the ports may be redistributed in equal parts between both the ports, in spite of the rather small electromagnetic interactions. Such an anomalous crosstalk is expected to appear at optical frequencies in lateral GaAs double quantum dots. A possible experimental set up is also discussed. The classical concepts of interference in the operation of electronic devices, which have been known since the early days of radio-communications and are associated with electromagnetic compatibility, should then be reconsidered at the nanoscale. (paper)

  11. Associative Interference in Pavlovian Conditioning: A Function of Similarity Between the Interfering and Target Associative Structures

    OpenAIRE

    Amundson, Jeffrey C.; Miller, Ralph R.

    2008-01-01

    Three lever-press suppression studies were conducted with water-deprived rats to investigate the role of similarity in proactive interference within first-order Pavlovian conditioning. Experiments 1a and 1b assessed the influence of stimulus complexity in proactive interference. Both experiments found greater interference when the interfering cue and target cue were composed of the same number of elements. Experiment 2 assessed the influence of context similarity in proactive interference and...

  12. Selective interference with pacemaker activity by electrical dental devices.

    Science.gov (United States)

    Miller, C S; Leonelli, F M; Latham, E

    1998-01-01

    We sought to determine whether electromagnetic interference with cardiac pacemakers occurs during the operation of contemporary electrical dental equipment. Fourteen electrical dental devices were tested in vitro for their ability to interfere with the function of two Medtronics cardiac pacemakers (one a dual-chamber, bipolar Thera 7942 pacemaker, the other a single-chamber, unipolar Minix 8340 pacemaker). Atrial and ventricular pacemaker output and electrocardiographic activity were monitored by means of telemetry with the use of a Medtronics 9760/90 programmer. Atrial and ventricular pacing were inhibited by electromagnetic interference produced by the electrosurgical unit up to a distance of 10 cm, by the ultrasonic bath cleaner up to 30 cm, and by the magnetorestrictive ultrasonic scalers up to 37.5 cm. In contrast, operation of the amalgamator, electric pulp tester, composite curing light, dental handpieces, electric toothbrush, microwave oven, dental chair and light, ENAC ultrasonic instrument, radiography unit, and sonic scaler did not alter pacing rate or rhythm. These results suggest that certain electrosurgical and ultrasonic instruments may produce deleterious effects in medically fragile patients with cardiac pacemakers.

  13. Electromagnetic radiation optimum neutralizer

    International Nuclear Information System (INIS)

    Smirnov, Igor

    2002-01-01

    This particular article relates to subtle electrical effects, and provides some evidence of a fundamental nature on how subtle low frequency electromagnetic fields might be utilized to protect human body against harmful effects of high frequencies electromagnetic radiation. I have focused my efforts on definite polar polymer compound named EMRON which is patented in the USA. This polar polymer compound can be excited by external high frequencies electromagnetic fields to generate subtle low frequency oscillations that are beneficial for cellular life structures. This concept is based on the possibility of existence of resonance phenomenon between polar polymers and biopolymers such as proteins, nucleic acids, lipids, etc. Low frequency patterns generated by defined polar polymer compound can interact with biostructures and transmit the signals that support and improve cellular functions in the body. The mechanism of this process was confirmed by number of studies. The animal (including human) brain is affected by electromagnetic waves to the extent that production of Alpha or Theta waves can be directly induced into brain by carrying an ELF (extremely low frequency, 5-12 Hz) signal on a microwave carrier frequency. EMRON does not reduce the power of electromagnetic fields. It 'shields' the cellular structures of the body against the harmful effects of EMR. The radiation is still entering the body but the neutralizing effect of EMRON renders the radiation harmless

  14. Electromagnetic fields and their impacts

    Science.gov (United States)

    Prša, M. A.; Kasaš-Lažetić, K. K.

    2018-01-01

    The main goal of this paper is to briefly recall some different electromagnetic field definitions, some macroscopic sources of electromagnetic fields, electromagnetic fields classification regarding time dependences, and the ways of field determination in concrete cases. After that, all the mechanisms of interaction between electromagnetic field and substance, on atomic level, are described in details. Interaction between substance and electric field is investigated separately from the substance and magnetic field interaction. It is demonstrated that, in all cases of the unique electromagnetic field, total interaction can be treated as a superposition of two separated interactions. Finally, the main electromagnetic fields surrounding us is cited and discussed.

  15. Exploiting Novel Radiation-Induced Electromagnetic Material Changes for Remote Detection and Monitoring: Final Progress Report

    Science.gov (United States)

    2016-04-01

    Exploiting Novel Radiation -Induced Electromagnetic Material Changes for Remote Detection and Monitoring: Final Progress Report Distribution...assess the effects of ionizing radiation on at least three classes of electromagnetic materials. The proposed approach for radiation detection was...that was desired to be monitored remotely. Microwave or low millimeter wave electromagnetic radiation would be used to interrogate the device

  16. Electromagnetic resonance in the asymmetric terahertz metamaterials with triangle microstructure

    Science.gov (United States)

    Xing, Yuanyuan; Zhang, Xiaoyu; Zhang, Qiang; Gu, Yanping; Qian, Yunan; Lin, Xingyue; Tang, Yunhai; Cheng, Xinli; Qin, Changfa; Shen, Jiaoyan; Zang, Taocheng; Ma, Chunlan

    2018-05-01

    We investigate terahertz transmission properties and electromagnetic resonance modes in the asymmetric triangle structures with the change of asymmetric distance and the direction of electric field. When the THz electric field is perpendicular to the split gap of triangle, the electric field can better excite the THz absorption in the triangle structures. Importantly, electromagnetically induced transparency (EIT) characteristics are observed in the triangle structures due to the destructive interference of the different excited modes. The distributions of electric field and surface current density simulated by finite difference time domain indicate that the bright mode is excited by the side of triangle structures and dark mode is excited by the gap-side of triangle. The present study is helpful to understand the electromagnetic resonance in the asymmetric triangular metamaterials.

  17. Gravitation and electromagnetism

    CERN Document Server

    Apsel, D

    1979-01-01

    Through an examination of the Bohm-Aharonov experiment, a new theory of gravitation and electromagnetism is proposed. The fundamental assumption of the theory is that the motion of a particle in a combination of gravitational and electromagnetic fields is determined from a variational principle of the form delta integral /sub A//sup B /d tau =0. The form of the physical time is determined from an examination of the Maxwell-Einstein action function. The field and motion equations are formally identical to those of Maxwell-Einstein theory. The theory predicts that even in a field-free region of space, electromagnetic potentials can alter the phase of a wave function and the lifetime of a charged particle. The phase alteration has been observed in the Bohm-Aharonov experiment. There is an indication that the lifetime alteration has shown up in a recent CERN storage ring experiment. Experimental tests are proposed. (11 refs).

  18. Applied electromagnetic scattering theory

    CERN Document Server

    Osipov, Andrey A

    2017-01-01

    Besides classical applications (radar and stealth, antennas, microwave engineering), scattering and diffraction are enabling phenomena for some emerging research fields (artificial electromagnetic materials or metamaterials, terahertz technologies, electromagnetic aspects of nano-science). This book is a tutorial for advanced students who need to study diffraction theory. The textbook gives fundamental knowledge about scattering and diffraction of electromagnetic waves and provides some working examples of solutions for practical high-frequency scattering and diffraction problems. The book focuses on the most important diffraction effects and mechanisms influencing the scattering process and describes efficient and physically justified simulation methods - physical optics (PO) and the physical theory of diffraction (PTD) - applicable in typical remote sensing scenarios. The material is presented in a comprehensible and logical form, which relates the presented results to the basic principles of electromag...

  19. Metamaterial electromagnetic wave absorbers.

    Science.gov (United States)

    Watts, Claire M; Liu, Xianliang; Padilla, Willie J

    2012-06-19

    The advent of negative index materials has spawned extensive research into metamaterials over the past decade. Metamaterials are attractive not only for their exotic electromagnetic properties, but also their promise for applications. A particular branch-the metamaterial perfect absorber (MPA)-has garnered interest due to the fact that it can achieve unity absorptivity of electromagnetic waves. Since its first experimental demonstration in 2008, the MPA has progressed significantly with designs shown across the electromagnetic spectrum, from microwave to optical. In this Progress Report we give an overview of the field and discuss a selection of examples and related applications. The ability of the MPA to exhibit extreme performance flexibility will be discussed and the theory underlying their operation and limitations will be established. Insight is given into what we can expect from this rapidly expanding field and future challenges will be addressed. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Electromagnetic compatibility of WLAN adapters with life-supporting medical devices.

    Science.gov (United States)

    Calcagnini, G; Mattei, E; Censi, F; Triventi, M; Lo Sterzo, R; Marchetta, E; Bartolini, P

    2011-05-01

    This paper investigates the electromagnetic compatibility of 45 critical care medical devices (infusion pumps, defibrillators, monitors, lung ventilators, anesthesia machines and external pacemakers) with various types of wireless local area network (WLAN, IEEE 802.11 b/g, 2.45 GHz, 100 mW) adapters. Interference is evaluated by performing ad-hoc tests according to the ANSI C63.18 recommended practice. The behavior of the devices during the tests was monitored using patient simulators/device testers specific for each device class. Electromagnetic interference cases were observed in three of 45 devices at a maximum distance of 5 cm. In two cases the interference caused malfunctions that may have clinical consequences for the patient. The authors' findings show that the use of these wireless local area network adapters can be considered reasonably safe, although interference may occur if they are operated at very close distance (<10 cm) to the medical devices.

  1. The theory of electromagnetism

    CERN Document Server

    Jones, D S

    1964-01-01

    The Theory of the Electomagnetism covers the behavior of electromagnetic fields and those parts of applied mathematics necessary to discover this behavior. This book is composed of 11 chapters that emphasize the Maxwell's equations. The first chapter is concerned with the general properties of solutions of Maxwell's equations in matter, which has certain macroscopic properties. The succeeding chapters consider specific problems in electromagnetism, including the determination of the field produced by a variable charge, first in isolation and then in the surface distributions of an antenna. The

  2. Lectures on electromagnetism

    CERN Document Server

    Das, Ashok

    2013-01-01

    These lecture notes on electromagnetism have evolved from graduate and undergraduate EM theory courses given by the author at the University of Rochester, with the basics presented with clarity and his characteristic attention to detail. The thirteen chapters cover, in logical sequence, topics ranging from electrostatics, magnetostatics and Maxwell's equations to plasmas and radiation. Boundary value problems are treated extensively, as are wave guides, electromagnetic interactions and fields. This second edition comprises many of the topics expanded with more details on the derivation of vari

  3. Electromagnetic clutches and couplings

    CERN Document Server

    Vorob'Yeva, T M; Fry, D W; Higinbotham, W

    2013-01-01

    Electromagnetic Clutches and Couplings contains a detailed description of U.S.S.R. electromagnetic friction clutches, magnetic couplings, and magnetic particle couplings. This book is divided into four chapters. The first chapter discusses the design and construction of magnetic (solenoid-operated) couplings, which are very quick-acting devices and used in low power high-speed servo-systems. Chapter 2 describes the possible fields of application, design, construction, and utilization of magnetic particle couplings. The aspects of construction, design, and utilization of induction clutches (sli

  4. Improved Electromagnetic Brake

    Science.gov (United States)

    Martin, Toby B.

    2004-01-01

    A proposed design for an electromagnetic brake would increase the reliability while reducing the number of parts and the weight, relative to a prior commercially available electromagnetic brake. The reductions of weight and the number of parts could also lead to a reduction of cost. A description of the commercial brake is prerequisite to a description of the proposed electromagnetic brake. The commercial brake (see upper part of figure) includes (1) a permanent magnet and an electromagnet coil on a stator and (2) a rotor that includes a steel contact plate mounted, with tension spring loading, on an aluminum hub. The stator is mounted securely on a stationary object, which would ordinarily be the housing of a gear drive or a motor. The rotor is mounted on the shaft of the gear drive or motor. The commercial brake nominally operates in a fail-safe (in the sense of normally braking) mode: In the absence of current in the electromagnet coil, the permanent magnet pulls the contact plate, against the spring tension, into contact with the stator. To release the brake, one excites the electromagnet with a current of the magnitude and polarity chosen to cancel the magnetic flux of the permanent magnet, thereby enabling the spring tension to pull the contact plate out of contact with the stator. The fail-safe operation of the commercial brake depends on careful mounting of the rotor in relation to the stator. The rotor/stator gap must be set with a tolerance between 10 and 15 mils (between about 0.25 and about 0.38 mm). If the gap or the contact pad is thicker than the maximum allowable value, then the permanent magnetic field will not be strong enough to pull the steel plate across the gap. (For this reason, any contact pad between the contact plate and the stator must also be correspondingly thin.) If the gap exceeds the maximum allowable value because of shaft end play, it becomes impossible to set the brake by turning off the electromagnet current. Although it may

  5. Essentials of Computational Electromagnetics

    CERN Document Server

    Sheng, Xin-Qing

    2012-01-01

    Essentials of Computational Electromagnetics provides an in-depth introduction of the three main full-wave numerical methods in computational electromagnetics (CEM); namely, the method of moment (MoM), the finite element method (FEM), and the finite-difference time-domain (FDTD) method. Numerous monographs can be found addressing one of the above three methods. However, few give a broad general overview of essentials embodied in these methods, or were published too early to include recent advances. Furthermore, many existing monographs only present the final numerical results without specifyin

  6. Developmental Change in Proactive Interference.

    Science.gov (United States)

    Kail, Robert

    2002-01-01

    Two studies examined age-related change in proactive interference from previously learned material. The meta-analysis of 26 studies indicated that proactive interference decreased with age. The cross-sectional study found that third through sixth graders' and college students' recall was accurate on Trial 1, but became less so over Trials 2…

  7. Sleep can reduce proactive interference.

    Science.gov (United States)

    Abel, Magdalena; Bäuml, Karl-Heinz T

    2014-01-01

    Sleep has repeatedly been connected to processes of memory consolidation. While extensive research indeed documents beneficial effects of sleep on memory, little is yet known about the role of sleep for interference effects in episodic memory. Although two prior studies reported sleep to reduce retroactive interference, no sleep effect has previously been found for proactive interference. Here we applied a study format differing from that employed by the prior studies to induce a high degree of proactive interference, and asked participants to encode a single list or two interfering lists of paired associates via pure study cycles. Testing occurred after 12 hours of diurnal wakefulness or nocturnal sleep. Consistent with the prior work, we found sleep in comparison to wake did not affect memory for the single list, but reduced retroactive interference. In addition we found sleep reduced proactive interference, and reduced retroactive and proactive interference to the same extent. The finding is consistent with the view that arising benefits of sleep are caused by the reactivation of memory contents during sleep, which has been suggested to strengthen and stabilise memories. Such stabilisation may make memories less susceptible to competition from interfering memories at test and thus reduce interference effects.

  8. Output Interference in Recognition Memory

    Science.gov (United States)

    Criss, Amy H.; Malmberg, Kenneth J.; Shiffrin, Richard M.

    2011-01-01

    Dennis and Humphreys (2001) proposed that interference in recognition memory arises solely from the prior contexts of the test word: Interference does not arise from memory traces of other words (from events prior to the study list or on the study list, and regardless of similarity to the test item). We evaluate this model using output…

  9. Interference Phenomenon with Mobile Displays

    Science.gov (United States)

    Trantham, Kenneth

    2015-01-01

    A simple experiment is presented in which the spacing and geometric pattern of pixels in mobile displays is measured. The technique is based on optical constructive interference. While the experiment is another opportunity to demonstrate wave interference from a grating-like structure, this can also be used to demonstrate concepts of solid state…

  10. Electromagnetic Fields in Reverberant Environments

    NARCIS (Netherlands)

    Vogt-Ardatjew, Robert Andrzej

    2017-01-01

    The phenomenon of resonating electromagnetic (EM) fields has been commonly and successfully exploited in reverberation chambers (RC) for the purpose of electromagnetic compatibility (EMC) testing, as well as modeling multipath environments. Although largely successful, the currently used statistical

  11. New perspectives on classical electromagnetism

    OpenAIRE

    Cote, Paul J.

    2009-01-01

    The fallacies associated with the gauge concept in electromagnetism are illustrated. A clearer and more valid formulation of the basics of classical electromagnetism is provided by recognizing existing physical constraints as well as the physical reality of the vector potential.

  12. Electromagnetic fields in stratified media

    CERN Document Server

    Li, Kai

    2009-01-01

    Dealing with an important branch of electromagnetic theory with many useful applications in subsurface communication, radar, and geophysical prospecting and diagnostics, this book introduces electromagnetic theory and wave propagation in complex media.

  13. Communications in interference limited networks

    CERN Document Server

    2016-01-01

    This book offers means to handle interference as a central problem of operating wireless networks. It investigates centralized and decentralized methods to avoid and handle interference as well as approaches that resolve interference constructively. The latter type of approach tries to solve the joint detection and estimation problem of several data streams that share a common medium. In fact, an exciting insight into the operation of networks is that it may be beneficial, in terms of an overall throughput, to actively create and manage interference. Thus, when handled properly, "mixing" of data in networks becomes a useful tool of operation rather than the nuisance as which it has been treated traditionally. With the development of mobile, robust, ubiquitous, reliable and instantaneous communication being a driving and enabling factor of an information centric economy, the understanding, mitigation and exploitation of interference in networks must be seen as a centrally important task.

  14. Ray-tracing techniques to assess the electromagnetic field radiated by radio base stations: Application and experimental validation in an urban environment

    International Nuclear Information System (INIS)

    Adda, S.; Anglesio, L.; D'Amore, G.; Mantovan, M.; Menegolli, M.

    2004-01-01

    This paper aims to validate a ray-tracing model for electromagnetic field calculation, which is used in urban environments to predict irradiation from radio base stations for population exposure evaluation. Validation was carried out through a measurement campaign by choosing measurement points in order to test different propagation environments and analysing broadcast control channels through narrow band measurements. Comparison of the calculated and measured fields indicates that the ray-tracing model used calculates electric field with good accuracy, in spite of the fact that the propagation environment is not described in detail, because of difficulties in modelling the geometrical and electrical characteristics of urban areas. Differences between the calculated and measured results remain below 1.5 dB, with a mean value of 1 dB. (authors)

  15. Computer aided method of low voltage power distribution networks protection system against lightning and electromagnetic pulse generated by high altitude nuclear burst

    International Nuclear Information System (INIS)

    Laroubine, J.

    1989-01-01

    The lightning creates an electromagnetic field which produces a slow duration and high energy pulse of current on low voltage power distribution networks. On the other hand an high altitude nuclear burst generates an electromagnetic pulse which causes fast and intense interferences. We describe here the specifications of a passive filter that can reject these interferences. We used a computer aided method of simulation to create a prototype. Experimental results confirm the validity of the model used for simulation [fr

  16. Low frequency electromagnetic field sensor

    International Nuclear Information System (INIS)

    Zhu Min; Zhou Yan; He Yicheng; Zheng Zhenxing; Liu Sunkun

    2000-01-01

    The measurement technique of low frequency electromagnetic field is reported. According to this principle, the authors have designed a sensor, which is used to measure the natural electromagnetic field, SLEMP and electromagnetic signals generated by some explosions. The frequency band of this sensor is from 0.08 Hz to 2 MHz

  17. Electromagnetic radiation detector

    Science.gov (United States)

    Benson, Jay L.; Hansen, Gordon J.

    1976-01-01

    An electromagnetic radiation detector including a collimating window, a cathode member having a photoelectric emissive material surface angularly disposed to said window whereby radiation is impinged thereon at acute angles, an anode, separated from the cathode member by an evacuated space, for collecting photoelectrons emitted from the emissive cathode surface, and a negatively biased, high transmissive grid disposed between the cathode member and anode.

  18. Disconnected electromagnetic form factors

    International Nuclear Information System (INIS)

    Wilcox, Walter

    2001-01-01

    Preliminary results of a calculation of disconnected nucleon electromagnetic factors factors on the lattice are presented. The implementation of the numerical subtraction scheme is outlined. A comparison of results for electric and magnetic disconnected form factors on two lattice sizes with those of the Kentucky group is presented. Unlike previous results, the results found in this calculation are consistent with zero in these sectors

  19. Electromagnetic distance measurement

    CERN Document Server

    1967-01-01

    This book brings together the work of forty-eight geodesists from twenty-five countries. They discuss various new electromagnetic distance measurement (EDM) instruments - among them the Tellurometer, Geodimeter, and air- and satellite-borne systems - and investigate the complex sources of error.

  20. Equivalence principles and electromagnetism

    Science.gov (United States)

    Ni, W.-T.

    1977-01-01

    The implications of the weak equivalence principles are investigated in detail for electromagnetic systems in a general framework. In particular, it is shown that the universality of free-fall trajectories (Galileo weak equivalence principle) does not imply the validity of the Einstein equivalence principle. However, the Galileo principle plus the universality of free-fall rotation states does imply the Einstein principle.

  1. Electromagnetic Environments Simulator (EMES)

    International Nuclear Information System (INIS)

    Varnado, G.B.

    1975-11-01

    A multipurpose electromagnetic environments simulator has been designed to provide a capability for performing EMR, EMP, and lightning near stroke testing of systems, subsystems and components in a single facility. This report describes the final facility design and presents the analytical and experimental verification of the design

  2. Electromagnetic structure of nuclei

    International Nuclear Information System (INIS)

    Arnold, R.G.

    1986-07-01

    A brief review is given of selected topics in the electromagnetic structure of nucleons and nuclei, including nucleon form factors from both quantum chromodynamics and electron scattering data, measurements of the deuteron and triton form factors, quasi-elastic scattering, and the EMC effect. 47 refs., 13 figs

  3. "Hearing" Electromagnetic Waves

    Science.gov (United States)

    Rojo, Marta; Munoz, Juan

    2014-01-01

    In this work, an educational experience is described in which a microwave communication link is used to make students aware that all electromagnetic waves have the same physical nature and properties. Experimental demonstrations are linked to theoretical concepts to increase comprehension of the physical principles underlying electromagnetic…

  4. Electromagnetic resonance waves

    International Nuclear Information System (INIS)

    Villaba, J.M.; Manjon, F.J.; Guirao, A.; Andres, M.V.

    1994-01-01

    We describe in this paper a set of experiments designed to make qualitative and quantitative measurements on electromagnetic resonances of several simple systems. The experiments are designed for the undergraduate laboratory of Electricity and Magnetism in Physics. These experiments can help the students understanding the concept of resonance, which appears in different fields of Physics. (Author) 8 refs

  5. Radio Frequency Interference Mitigation

    Science.gov (United States)

    An, T.; Chen, X.; Mohan, P.; Lao, B. Q.

    2017-09-01

    The observational facilities of radio astronomy keep constant upgrades and developments to achieve better capabilities including increasing the time of the data recording and frequency resolutions, and increasing the receiving and recording bandwidth. However in contrast, only a limited spectrum resource has been allocated to radio astronomy by the International Telecommunication Union, resulting in that the radio observational instrumentations are inevitably exposed to undesirable radio frequency interference (RFI) signals which originate mainly from the terrestrial human activity and are becoming stronger with time. RFIs degrade the quality of data and even lead to invalid data. The impact of RFIs on scientific outcome becomes more and more serious. In this article, the requirement for RFI mitigation is motivated, and the RFI characteristics, mitigation techniques, and strategies are reviewed. The mitigation strategies adopted at some representative observatories, telescopes, and arrays are also introduced. The advantages and shortcomings of the four classes of RFI mitigation strategies are discussed and presented, applicable at the connected causal stages: preventive, pre-detection, pre-correlation, and post-correlation. The proper identification and flagging of RFI is the key to the reduction of data loss and improvement in data quality, and is also the ultimate goal of developing RFI mitigation technique. This can be achieved through a strategy involving a combination of the discussed techniques in stages. The recent advances in the high speed digital signal processing and high performance computing allow for performing RFI excision of the large data volumes generated from large telescopes or arrays in both real time and offline modes, aiding the proposed strategy.

  6. A Circuit Design and its Experimental Analysis for Electromagnetic Flowmeter in Measurement of Sewage

    Directory of Open Access Journals (Sweden)

    Huang Yu-Hang

    2014-02-01

    Full Text Available There are many problems in the traditional electromagnetic flowmeter. The problems involve three aspects. The first one is that the measurement precision is low. The second one is that the measurement range is narrow. The third one is that the test results are susceptible to interference. For the problems a new electromagnetic flowmeter controlled by single-chip microcomputer has been proposed. The medium/large-sized electromagnetic flowmeter is suitable for measurement of sewage. The software and hardware circuit of the electromagnetic flowmeter has been designed and tested. The tested data have been analyzed by the least square method and the error is 0.8 %. The result shown that the electromagnetic flowmeter controlled by single-chip microcomputer for measurement of sewage has reached the advanced level of similar products at home and abroad.

  7. Electromagnetic compatibility of PLC adapters for in-home/domestic networks

    Science.gov (United States)

    Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek

    2018-01-01

    The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].

  8. Gauge theory of weak, electromagnetic and dual electromagnetic interactions

    International Nuclear Information System (INIS)

    Soln, J.

    1980-01-01

    An SU 2 x U 1 algebra, in addition to the ordinary electric charge, also establishes the existence of the dual electric charge. This is taken as an indication of the existence of dual electromagnetic interactions in nature. Here, the unification of weak, electromagnetic and dual electromagnetic interactions is performed. The Yang-Mills-type group which contains the electromagnetic, dual electromagnetic and weak currents is SUsub(L,2) x U 1 x U' 1 . The masses of vector mesons are generated through the Higgs-Kibble mechanism. A simple consistency requirement suggests that dual electromagnetism and ordinary electromagnetism have the same strengths, leading the theory to a rather good agreement with experiments. (author)

  9. Electromagnetic scattering from buried objects

    International Nuclear Information System (INIS)

    Brock, B.C.; Sorensen, K.W.

    1994-10-01

    Radar imaging and detection of objects buried in soil has potentially important applications in the areas of nonproliferation of weapons, environmental monitoring, hazardous-waste site location and assessment, and even archeology. In order to understand and exploit this potential, it is first necessary to understand how the soil responds to an electromagnetic wave, and how targets buried within the soil scatter the electromagnetic wave. We examine the response of the soil to a short pulse, and illustrate the roll of the complex dielectric permittivity of the soil in determining radar range resolution. This leads to a concept of an optimum frequency and bandwidth for imaging in a particular soil. We then propose a new definition for radar cross section which is consistent with the modified radar equation for use with buried targets. This radar cross section plays the same roll in the modified radar equation as the traditional radar cross section does in the free-space radar equation, and is directly comparable to it. The radar cross section of several canonical objects in lossy media is derived, and examples are given for several object/soil combinations

  10. Belief attribution despite verbal interference.

    Science.gov (United States)

    Forgeot d'Arc, Baudouin; Ramus, Franck

    2011-05-01

    False-belief (FB) tasks have been widely used to study the ability of individuals to represent the content of their conspecifics' mental states (theory of mind). However, the cognitive processes involved are still poorly understood, and it remains particularly debated whether language and inner speech are necessary for the attribution of beliefs to other agents. We present a completely nonverbal paradigm consisting of silent animated cartoons in five closely related conditions, systematically teasing apart different aspects of scene analysis and allowing the assessment of the attribution of beliefs, goals, and physical causation. In order to test the role of language in belief attribution, we used verbal shadowing as a dual task to inhibit inner speech. Data on 58 healthy adults indicate that verbal interference decreases overall performance, but has no specific effect on belief attribution. Participants remained able to attribute beliefs despite heavy concurrent demands on their verbal abilities. Our results are most consistent with the hypothesis that belief attribution is independent from inner speech.

  11. Wave propagation in electromagnetic media

    International Nuclear Information System (INIS)

    Davis, J.L.

    1990-01-01

    This book is concerned with wave propagation in reacting media, specifically in electromagnetic materials. An account is presented of the mathematical methods of wave phenomena in electromagnetic materials. The author presents the theory of time-varying electromagnetic fields, which involves a discussion of Faraday's laws, Maxwell's equations and their application to electromagnetic wave propagation under a variety of conditions. The author gives a discussion of magnetohydrodynamics and plasma physics. Chapters are included on quantum mechanics and the theory of relativity. The mathematical foundation of electromagnetic waves vis a vis partial differential equations is discussed

  12. Interference management using direct sequence spread spectrum ...

    African Journals Online (AJOL)

    Interference management using direct sequence spread spectrum (DSSS) technique ... Journal of Fundamental and Applied Sciences ... Keywords: DSSS, LTE network; Wi-Fi network; SINR; interference management and interference power.

  13. Optical interference with noncoherent states

    International Nuclear Information System (INIS)

    Sagi, Yoav; Firstenberg, Ofer; Fisher, Amnon; Ron, Amiram

    2003-01-01

    We examine a typical two-source optical interference apparatus consisting of two cavities, a beam splitter, and two detectors. We show that field-field interference occurs even when the cavities are not initially in coherent states but rather in other nonclassical states. However, we find that the visibility of the second-order interference, that is, the expectation values of the detectors' readings, changes from 100%, when the cavities are prepared in coherent states, to zero visibility when they are initially in single Fock states. We calculate the fourth-order interference, and for the latter case find that it corresponds to a case where the currents oscillate with 100% visibility, but with a random phase for every experiment. Finally, we suggest an experimental realization of the apparatus with nonclassical sources

  14. Quantum Erasure: Quantum Interference Revisited

    OpenAIRE

    Walborn, Stephen P.; Cunha, Marcelo O. Terra; Pádua, Sebastião; Monken, Carlos H.

    2005-01-01

    Recent experiments in quantum optics have shed light on the foundations of quantum physics. Quantum erasers - modified quantum interference experiments - show that quantum entanglement is responsible for the complementarity principle.

  15. Interference, reduced action, and trajectories

    OpenAIRE

    Floyd, Edward R.

    2006-01-01

    Instead of investigating the interference between two stationary, rectilinear wave functions in a trajectory representation by examining the two rectilinear wave functions individually, we examine a dichromatic wave function that is synthesized from the two interfering wave functions. The physics of interference is contained in the reduced action for the dichromatic wave function. As this reduced action is a generator of the motion for the dichromatic wave function, it determines the dichroma...

  16. Barriers to repeated assessment of verbal learning and memory: a comparison of international shopping list task and rey auditory verbal learning test on build-up of proactive interference.

    Science.gov (United States)

    Rahimi-Golkhandan, S; Maruff, P; Darby, D; Wilson, P

    2012-11-01

    Proactive interference (PI) that remains unidentified can confound the assessment of verbal learning, particularly when its effects vary from one population to another. The International Shopping List Task (ISLT) is a new measure that provides multiple forms that can be equated for linguistic factors across cultural groups. The aim of this study was to examine the build-up of PI on two measures of verbal learning-a traditional test of list learning (Rey Auditory Verbal Learning Test, RAVLT) and the ISLT. The sample consisted of 61 healthy adults aged 18-40. Each test had three parallel forms, each recalled three times. Results showed that repeated administration of the ISLT did not result in significant PI effects, unlike the RAVLT. Although these PI effects, observed during short retest intervals, may not be as robust under normal clinical administrations of the tests, the results suggest that the choice of the verbal learning test should be guided by the knowledge of PI effects and the susceptibility of particular patient groups to this effect.

  17. Electromagnetic wave energy converter

    Science.gov (United States)

    Bailey, R. L. (Inventor)

    1973-01-01

    Electromagnetic wave energy is converted into electric power with an array of mutually insulated electromagnetic wave absorber elements each responsive to an electric field component of the wave as it impinges thereon. Each element includes a portion tapered in the direction of wave propagation to provide a relatively wideband response spectrum. Each element includes an output for deriving a voltage replica of the electric field variations intercepted by it. Adjacent elements are positioned relative to each other so that an electric field subsists between adjacent elements in response to the impinging wave. The electric field results in a voltage difference between adjacent elements that is fed to a rectifier to derive dc output power.

  18. Electromagnetic fields and waves

    CERN Document Server

    Iskander, Magdy F

    2013-01-01

    The latest edition of Electromagnetic Fields and Waves retains an authoritative, balanced approach, in-depth coverage, extensive analysis, and use of computational techniques to provide a complete understanding of electromagnetic—important to all electrical engineering students. An essential feature of this innovative text is the early introduction of Maxwell's equations, together with the quantifying experimental observations made by the pioneers who discovered electromagnetics. This approach directly links the mathematical relations in Maxwell's equations to real experiments and facilitates a fundamental understanding of wave propagation and use in modern practical applications, especially in today's wireless world. New and expanded topics include the conceptual relationship between Coulomb's law and Gauss's law for calculating electric fields, the relationship between Biot-Savart's and Ampere's laws and their use in calculating magnetic fields from current sources, the development of Faraday's law from e...

  19. Nanofocusing of electromagnetic radiation

    DEFF Research Database (Denmark)

    Gramotnev, D. K.; Bozhevolnyi, Sergey I.

    2014-01-01

    Nanofocusing of electromagnetic radiation, that is, reducing the cross sections of propagating optical modes far beyond the diffraction limit in dielectric media, can be achieved in tapered metal-dielectric waveguides that support surface plasmon-polariton modes. Although the main principles...... radiation on the nanoscale. Here, we present the underlying physical principles of radiation nanofocusing in metallic nanostructures, overview recent progress and major developments, and consider future directions and potential applications of this subfield of nano-optics....

  20. Electromagnetic Hammer for Metalworking

    Science.gov (United States)

    Anderson, S. A.; Brunet, F.; Dowd, A.; Durham, R.; Ezell, J.; Gorr, G.; Hartley, D.; Jackson, F.; Marchand, J.; Macfarlane, W.; hide

    1986-01-01

    High eddy currents apply pressure for cold-forming. Coil housing constructed for mechanical strength to hold coil against magnetic force, to maintain electrical contact with coil ends, and to maintain insulation between coil turns. Drilled holes placed to facilitate release of bubbles during potting. In contrast with mechanical hammers, electromagnetic hammer requires no dynamic material contact with workpiece; consequently, produces almost no change in metal grain structure.

  1. Electromagnetic compatibility and earths

    International Nuclear Information System (INIS)

    Duque Henao, Alan; Casas Ospina, Favio

    2001-01-01

    It is such the increment of applications of electric and electronic equipment in the modern companies that the lack of control of the electromagnetic perturbations, brings, get big losses and difficulties in the normal operations. The paper contribute to ago with base in the challenges that day-by-day are confronting, where the settings to earth, to be the foundation of the electric building, are fundamental for a good coexistence among the different equipment s

  2. Hard Electromagnetic Processes

    International Nuclear Information System (INIS)

    Richard, F.

    1987-09-01

    Among hard electromagnetic processes, I will use the most recent data and focus on quantitative test of QCD. More specifically, I will retain two items: - hadroproduction of direct photons, - Drell-Yan. In addition, I will briefly discuss a recent analysis of ISR data obtained with AFS (Axial Field Spectrometer) which sheds a new light on the e/π puzzle at low P T

  3. Introduction to electromagnetic theory

    CERN Document Server

    Owen, George E

    2003-01-01

    A direct, stimulating approach to electromagnetic theory, this text employs matrices and matrix methods for the simple development of broad theorems. The author uses vector representation throughout the book, with numerous applications of Poisson's equation and the Laplace equation (the latter occurring in both electronics and magnetic media). Contents include the electrostatics of point charges, distributions of charge, conductors and dielectrics, currents and circuits, and the Lorentz force and the magnetic field. Additional topics comprise the magnetic field of steady currents, induced ele

  4. Electromagnetic polarizabilities of hadrons

    International Nuclear Information System (INIS)

    Friar, J.L.

    1988-01-01

    Electromagnetic polarizabilities of hadrons are reviewed, after a discussion of classical analogues. Differences between relativistic and non-relativistic approaches can lead to conflicts with conventional nuclear physics sum rules and calculational techniques. The nucleon polarizabilities are discussed in the context of the non-relativistic valence quark model, which provides a good qualitative description. The recently measured pion polarizabilities are discussed in the context of chiral symmetry and quark-loop models. 58 refs., 5 figs

  5. Electromagnetism and interconnections

    CERN Document Server

    Charruau, S

    2009-01-01

    This book covers the theoretical problems of modeling electrical behavior of the interconnections encountered in everyday electronic products. The coverage shows the theoretical tools of waveform prediction at work in the design of a complex and high-speed digital electronic system. Scientists, research engineers, and postgraduate students interested in electromagnetism, microwave theory, electrical engineering, or the development of simulation tools software for high speed electronic system design automation will find this book an illuminating resource.

  6. Mobile communication devices causing interference in invasive and noninvasive ventilators.

    Science.gov (United States)

    Dang, Bao P; Nel, Pierre R; Gjevre, John A

    2007-06-01

    The aim of this study was to assess if common mobile communication systems would cause significant interference on mechanical ventilation devices and at what distances would such interference occur. We tested all the invasive and noninvasive ventilatory devices used within our region. This consisted of 2 adult mechanical ventilators, 1 portable ventilator, 2 pediatric ventilators, and 2 noninvasive positive pressure ventilatory devices. We operated the mobile devices from the 2 cellular communication systems (digital) and 1 2-way radio system used in our province at varying distances from the ventilators and looked at any interference they created. We tested the 2-way radio system, which had a fixed operation power output of 3.0 watts, the Global Systems for Mobile Communication cellular system, which had a maximum power output of 2.0 watts and the Time Division Multiple Access cellular system, which had a maximum power output of 0.2 watts on our ventilators. The ventilators were ventilating a plastic lung at fixed settings. The mobile communication devices were tested at varying distances starting at zero meter from the ventilator and in all operation modes. The 2-way radio caused the most interference on some of the ventilators, but the maximum distance of interference was 1.0 m. The Global Systems for Mobile Communication system caused significant interference only at 0 m and minor interference at 0.5 m on only 1 ventilator. The Time Division Multiple Access system caused no interference at all. Significant interference consisted of a dramatic rise and fluctuation of the respiratory rate, pressure, and positive end-expiratory pressure of the ventilators with no normalization when the mobile device was removed. From our experiment on our ventilators with the communication systems used in our province, we conclude that mobile communication devices such as cellular phones and 2-way radios are safe and cause no interference unless operated at very close distances of

  7. Electromagnetic radiation unmasked

    International Nuclear Information System (INIS)

    Hart, P.

    1996-01-01

    This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields do harm, a policy of prudent avoidance is recommended, especially for children. ills

  8. The electromagnetic dark sector

    International Nuclear Information System (INIS)

    Jimenez, Jose Beltran; Maroto, Antonio L.

    2010-01-01

    We consider electromagnetic field quantization in an expanding universe. We find that the covariant (Gupta-Bleuler) method exhibits certain difficulties when trying to impose the quantum Lorenz condition on cosmological scales. We thus explore the possibility of consistently quantizing without imposing such a condition. In this case there are three physical states, which are the two transverse polarizations of the massless photon and a new massless scalar mode coming from the temporal and longitudinal components of the electromagnetic field. An explicit example in de Sitter space-time shows that it is still possible to eliminate the negative norm state and to ensure the positivity of the energy in this theory. The new state is decoupled from the conserved electromagnetic currents, but is non-conformally coupled to gravity and therefore can be excited from vacuum fluctuations by the expanding background. The cosmological evolution ensures that the new state modifies Maxwell's equations in a totally negligible way on sub-Hubble scales. However, on cosmological scales it can give rise to a non-negligible energy density which could explain in a natural way the present phase of accelerated expansion of the universe.

  9. Coherent hybrid electromagnetic field imaging

    Science.gov (United States)

    Cooke, Bradly J [Jemez Springs, NM; Guenther, David C [Los Alamos, NM

    2008-08-26

    An apparatus and corresponding method for coherent hybrid electromagnetic field imaging of a target, where an energy source is used to generate a propagating electromagnetic beam, an electromagnetic beam splitting means to split the beam into two or more coherently matched beams of about equal amplitude, and where the spatial and temporal self-coherence between each two or more coherently matched beams is preserved. Two or more differential modulation means are employed to modulate each two or more coherently matched beams with a time-varying polarization, frequency, phase, and amplitude signal. An electromagnetic beam combining means is used to coherently combine said two or more coherently matched beams into a coherent electromagnetic beam. One or more electromagnetic beam controlling means are used for collimating, guiding, or focusing the coherent electromagnetic beam. One or more apertures are used for transmitting and receiving the coherent electromagnetic beam to and from the target. A receiver is used that is capable of square-law detection of the coherent electromagnetic beam. A waveform generator is used that is capable of generation and control of time-varying polarization, frequency, phase, or amplitude modulation waveforms and sequences. A means of synchronizing time varying waveform is used between the energy source and the receiver. Finally, a means of displaying the images created by the interaction of the coherent electromagnetic beam with target is employed.

  10. Electromagnetic force on a brane

    International Nuclear Information System (INIS)

    Li, Li-Xin

    2016-01-01

    A fundamental assumption in the theory of brane world is that all matter and radiation are confined on the four-dimensional brane and only gravitons can propagate in the five-dimensional bulk spacetime. The brane world theory did not provide an explanation for the existence of electromagnetic fields and the origin of the electromagnetic field equation. In this paper, we propose a model for explaining the existence of electromagnetic fields on a brane and deriving the electromagnetic field equation. Similar to the case in Kaluza–Klein theory, we find that electromagnetic fields and the electromagnetic field equation can be derived from the five-dimensional Einstein field equation. However, the derived electromagnetic field equation differs from the Maxwell equation by containing a term with the electromagnetic potential vector coupled to the spacetime curvature tensor. So it can be considered as generalization of the Maxwell equation in a curved spacetime. The gravitational field equation on the brane is also derived with the stress–energy tensor for electromagnetic fields explicitly included and the Weyl tensor term explicitly expressed with matter fields and their derivatives in the direction of the extra-dimension. The model proposed in the paper can be regarded as unification of electromagnetic and gravitational interactions in the framework of brane world theory. (paper)

  11. [Fundamentally new electromagnetic pollution and the lack of adequate regulatory framework--on the risk assessment (analysis of modern domestic and foreign data)].

    Science.gov (United States)

    Grigorev, Yu G

    2014-01-01

    On the base of the study of the numerous experimental and epidemiological studies electromagnetic radiation (EMR) of mobile communications were found to adversely affect on the health of the population. Analysis of the influence of radio frequency (RF) radiation from mobile phones (MPs) on the brain of users showed that this organ body is most exposed to this radiation, especially in children. As a result of the performed research there were recorded functional changes in children--MPs users: undue fatiguability (39.7%), decreased performance in the school and at home (50.7%), weakening of the stability of voluntary attention (productivity--14.3%, accuracy 19.4%) and semantic memory (accuracy--19.4% increase in the time--30.1%). In addition, a marked change in the rate of auditory- motor response (55.5%), and disturbances of phonemic perception have been noted. The existing legal framework on the influence of EMR on human health was shown not fully to meet the hygiene requirements in connection with the absence of her normative parameters which determine the impact of complicately modulated radiation from MPs and base stations. The need for additional research on the influence of the modulated RF EMR on the human body and creation of a regulatory framework taking into account the sum of biological effects, especially on the critical organ of human--brain is substantiated by the author. When creating a regulatory framework it must be taken into account the scientific beliefs on the possible development of long-term brain pathologies under the combined effect of EMF, especially in children.

  12. Widespread nanoparticle-assay interference: implications for nanotoxicity testing.

    Science.gov (United States)

    Ong, Kimberly J; MacCormack, Tyson J; Clark, Rhett J; Ede, James D; Ortega, Van A; Felix, Lindsey C; Dang, Michael K M; Ma, Guibin; Fenniri, Hicham; Veinot, Jonathan G C; Goss, Greg G

    2014-01-01

    The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1) nanoparticle intrinsic fluorescence/absorbance, 2) interactions between nanoparticles and assay components, and 3) the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments.

  13. Widespread nanoparticle-assay interference: implications for nanotoxicity testing.

    Directory of Open Access Journals (Sweden)

    Kimberly J Ong

    Full Text Available The evaluation of engineered nanomaterial safety has been hindered by conflicting reports demonstrating differential degrees of toxicity with the same nanoparticles. The unique properties of these materials increase the likelihood that they will interfere with analytical techniques, which may contribute to this phenomenon. We tested the potential for: 1 nanoparticle intrinsic fluorescence/absorbance, 2 interactions between nanoparticles and assay components, and 3 the effects of adding both nanoparticles and analytes to an assay, to interfere with the accurate assessment of toxicity. Silicon, cadmium selenide, titanium dioxide, and helical rosette nanotubes each affected at least one of the six assays tested, resulting in either substantial over- or under-estimations of toxicity. Simulation of realistic assay conditions revealed that interference could not be predicted solely by interactions between nanoparticles and assay components. Moreover, the nature and degree of interference cannot be predicted solely based on our current understanding of nanomaterial behaviour. A literature survey indicated that ca. 95% of papers from 2010 using biochemical techniques to assess nanotoxicity did not account for potential interference of nanoparticles, and this number had not substantially improved in 2012. We provide guidance on avoiding and/or controlling for such interference to improve the accuracy of nanotoxicity assessments.

  14. Fast breeder reactor electromagnetic pump

    International Nuclear Information System (INIS)

    Araseki, Hideo; Murakami, Takahiro

    2008-01-01

    Main pumps circulating sodium in the FBR type reactor have been mechanical types, not electromagnetic pumps. Electromagnetic pump of 1-2 m 3 /min has been used as an auxiliary pump. Large sized electromagnetic pumps such as several hundred m 3 /min have not been commercialized due to technical difficulties with electromagnetic instability and pressure pulsations. This article explained electromagnetic and fluid equations and magnetic Reynolds number related with electromagnetic pumps and numerical analysis of instability characteristics and pressure pulsations and then described applications of the results to FBR system. Magnetic Reynolds number must be chosen less than one with appropriate operating frequency and optimum slip of 0.2-0.4. (T. Tanaka)

  15. Interference effects with surface plasmons

    NARCIS (Netherlands)

    Kuzmin, Nikolay Victorovich

    2008-01-01

    A surface plasmon is a purely two-dimensional electromagnetic excitation bound to the interface between metal and dielectric and quickly decaying away from it. A surface plasmon is able to concentrate light on sub-wavelength scales – a feature that is attractive for nano-photonics and integrated

  16. A Decentralized Receiver in Gaussian Interference

    Directory of Open Access Journals (Sweden)

    Christian D. Chapman

    2018-04-01

    Full Text Available Bounds are developed on the maximum communications rate between a transmitter and a fusion node aided by a cluster of distributed receivers with limited resources for cooperation, all in the presence of an additive Gaussian interferer. The receivers cannot communicate with one another and can only convey processed versions of their observations to the fusion center through a Local Array Network (LAN with limited total throughput. The effectiveness of each bound’s approach for mitigating a strong interferer is assessed over a wide range of channels. It is seen that, if resources are shared effectively, even a simple quantize-and-forward strategy can mitigate an interferer 20 dB stronger than the signal in a diverse range of spatially Ricean channels. Monte-Carlo experiments for the bounds reveal that, while achievable rates are stable when varying the receiver’s observed scattered-path to line-of-sight signal power, the receivers must adapt how they share resources in response to this change. The bounds analyzed are proven to be achievable and are seen to be tight with capacity when LAN resources are either ample or limited.

  17. Interference in motor learning - is motor interference sensory?

    DEFF Research Database (Denmark)

    Jensen, Jesper Lundbye; Petersen, Tue Hvass; Rothwell, John C

    mechanisms determine whether or not interference occurs. We hypothesised that interference requires the same neural circuits to be engaged in the two tasks and provoke competing processes of synaptic plasticity. To test this, subjects learned a ballistic ankle plantarflexion task. Early motor memory...... was disrupted by subsequent learning of a precision tracking task with the same agonist muscle group, but not by learning involving antagonist muscles or by voluntary agonist contractions that did not require learning. If the competing task was learned with the same agonist muscle group 4 hours following...

  18. PROBABILISTIC APPROACH OF STABILIZED ELECTROMAGNETIC FIELD EFFECTS

    Directory of Open Access Journals (Sweden)

    FELEA. I.

    2017-09-01

    Full Text Available The effects of the omnipresence of the electromagnetic field are certain and recognized. Assessing as accurately as possible these effects, which characterize random phenomena require the use of statistical-probabilistic calculation. This paper aims at assessing the probability of exceeding the admissible values of the characteristic sizes of the electromagnetic field - magnetic induction and electric field strength. The first part justifies the need for concern and specifies how to approach it. The mathematical model of approach and treatment is presented in the second part of the paper and the results obtained with reference to 14 power stations are synthesized in the third part. In the last part, are formulated the conclusions of the evaluations.

  19. Method of moments in electromagnetics

    CERN Document Server

    Gibson, Walton C

    2007-01-01

    Responding to the need for a clear, up-to-date introduction to the field, The Method of Moments in Electromagnetics explores surface integral equations in electromagnetics and presents their numerical solution using the method of moments (MOM) technique. It provides the numerical implementation aspects at a nuts-and-bolts level while discussing integral equations and electromagnetic theory at a higher level. The author covers a range of topics in this area, from the initial underpinnings of the MOM to its current applications. He first reviews the frequency-domain electromagnetic theory and t

  20. Electromagnetic fields in biological systems

    National Research Council Canada - National Science Library

    Lin, James C

    2012-01-01

    "Focusing on exposure, induced fields, and absorbed energy, this volume covers the interaction of electromagnetic fields and waves with biological systems, spanning static fields to terahertz waves...

  1. Electromagnetic waves in stratified media

    CERN Document Server

    Wait, James R; Fock, V A; Wait, J R

    2013-01-01

    International Series of Monographs in Electromagnetic Waves, Volume 3: Electromagnetic Waves in Stratified Media provides information pertinent to the electromagnetic waves in media whose properties differ in one particular direction. This book discusses the important feature of the waves that enables communications at global distances. Organized into 13 chapters, this volume begins with an overview of the general analysis for the electromagnetic response of a plane stratified medium comprising of any number of parallel homogeneous layers. This text then explains the reflection of electromagne

  2. Handheld Broadband Electromagnetic UXO Sensor

    National Research Council Canada - National Science Library

    Won, I. J; San Filipo, William A; Marqusee, Jeffrey; Andrews, Anne; Robitaille, George; Fairbanks, Jeffrey; Overbay, Larry

    2005-01-01

    The broadband electromagnetic sensor improvement and demonstration undertaken in this project took the prototype GEM-3 and evolved it into an operational sensor with increased bandwidth and dynamic...

  3. Battlefield Electromagnetic Environments Office (BEEO)

    Data.gov (United States)

    Federal Laboratory Consortium — The Battlefield Electromagnetic Environments Office (BEEO) develops, maintains, and operates the Army Materiel Command (AMC) databases for spectrum management, per...

  4. Scientific days on electromagnetic fields: from dosimetry to human health - Conference proceedings

    International Nuclear Information System (INIS)

    Wiart, J.; Ghanmi, A.; Picon, O.; Conil, E.; Varsier, N.; Hadjem, A.; Sudret, B.; Magne, I.; Souques, M.; Gaudaire, F.; De Seze, R.; Jawad, O.; Lautru, D.; Dricot, J.M.; Horlin, F.; De Doncker, P.; Drissaoui, A.; Musy, F.; Nicolas, L.; Perrussel, R.; Scorretti, R.; Voyer, D.; Jala, M.; Moulines, E.; Levy-Leduc, C.; Mahfouz, Z.; Gati, A.; Fouad Hanna, V.; Leveque, P.; Arnaud-Cormos, D.; Zhadobov, M.; Jarrige, P.; Gaborit, G.; Kohler, S.; Ticaud, N.; Duvillaret, L.; Guelilia, Z.; Loison, R.; Gillard, R.; Laisne, A.; Favet, D.; Benadhira, R.; Mir, L.; Nadi, M.; Kourtiche, D.; Gazeau, F.; Wilhelm, C.; Delemotte, L.; Breton, M.; Tarek, M.; Marc-Vergnes, J.P.; Yardin, C.; Perrin, A.; Le Drean, Y.; Sauleau, R.; Lambrozo, J.; Selmaoui, B.; Ghosn, R.; Thuroczy, G.; Villegier, A.S.; Loos, N.; Brenet-Dufour, V.; Liabeuf, S.; Bach, V.; Moretti, D.; Lewis, N.; Garenne, A.; Poulletier De Gannes, F.; Haro, E.; Lagroye, I.; Bornat, Y.; Boutaib, Y.; Saighi, S.; Renaud, S.; Veyre, B.; Schuz, J.; Deltour, I.; Van Deventer, E.; Vecchia, P.; Merckel, O.; Bellaouel, A.; Demaret, P.; Donati, P.; Jovanovic, D.; Chauvin, S.; Desreumaux, J.P.; Fouquet, L.; Picard, D.; Massardier-Pilonchery, A.; Hours, M.; Bergeret, A.; Person, C.; Toutain, Y.; Butet, R.; Berrahma, K.; Balderelli, I.; Stelmaszyk, V.; Cretallaz, C.; Lamproglou, I.; Amourette, C.; Diserbo, M.; Fauquette, W.; Martigne, P.; Collin, A.; Lagroye, I.; Ait Aissa, S.; Hurtier, A.; Taxile, M.; Le Montagner, L.; Athane, A.; Duleu, S.; Percherancier, Y.; Geffard, M.; Ruffie, G.; Billaudel, B.; Veyret, B.; Pelletier, A.; Delanaud, S.; Libert, J.P.; Schunck, T.; Bieth, F.; Soubere Mahamoud, Y.; Le Quement, C.; Ferrand, G.; Le Guevel, R.; Carton, P.H.; Luong, M.; Tanvir, S.; Selmaoui, B.; Silva Pires-Antonietti, V.; Sonnet, P.; Pulvin, S.; Kuster, O.; Tetelin, C.

    2012-04-01

    - Electromagnetic interferences and cardiac implants; 24 - RF effects on central nervous system: sleep, cognition, Electro-encephalography, vascularisation; 25 - Specific effects of an exposure to mobile phone RF waves on the autonomous nervous control of the cutaneous vasomotor tone; 26 - The ERNAM project: exposure of neuronal networks to the GSM-1800 signal; 27 - Mobile phones, power lines and cancer: the epidemiological evidence leading to classification as possible carcinogens; 28 - EMF Risk Assessment and Management: A WHO Perspective; 29 - Evolution of ICNIRP guidelines; 30 - Assessment of RF-linked risks at the Anses: from dialogue management recommendations; 31 - Characterization of mobile phone-absorbing medium interactions for non-invasive dosimetry; 32 - Status of electromagnetic radiation exposures and evaluation of prevention means; 33 - General public exposure to RF in France; 34 - Power emitted by a mobile phone in voice communication: from 2G to 3G VoIP; 35 - Digital dosimetry in HF/VHF range; 36 - Professional exposure of mobile phone maintenance technicians; 37 - Robot-less multi-sensors dosimetry for real time SAR measurement; 38 - High performance SAR meter for the characterization of 3G mobile phones exposure; 39 - RF dosemeters and user's body diffraction; 40 - RF waves and health: summary of 2007-2011 scientific publications; 41 - Behaviour of adult male wistar rats during high power pulsed electromagnetic waves (3 GHz); 42 - Wi-Fi effects: results of IMS Lab studies; 43 - Effects on the energy fluxes of young rats homeostasis during a chronic exposure to RF fields; 44 - Biological effects of very-high power and ultra-large range radiations: ISL's research programme; 45 - Study of cell-scale biological effects of pulsed RF fields used in high-resolution NMR-imaging; 46 - Effects of cell phone radiofrequency exposure on the human cytochrome P450 reductase; 47 - CEA's 'electromagnetic safety' working group; 48 - In situ evaluation of electromagnetic fields

  5. Electromagnetic shielding formulae

    International Nuclear Information System (INIS)

    Dahlberg, E.

    1979-02-01

    This addendum to an earlier collection of electromagnetic shielding formulae (TRITA-EPP-75-27) contains simple transfer matrices suitable for calculating the quasistatic shielding efficiency for multiple transverse-field and axial-field cylindrical and spherical shields, as well as for estimating leakage fields from long coaxial cables and the normal-incidence transmission of a plane wave through a multiple plane shield. The differences and similarities between these cases are illustrated by means of equivalent circuits and transmission line analogies. The addendum also includes a discussion of a possible heuristic improvement of some shielding formulae. (author)

  6. Introduction to electromagnetic engineering

    CERN Document Server

    Harrington, Roger E

    2003-01-01

    This study of electromagnetic theory introduces students to a broad range of quantities and concepts, imparting the necessary vector analysis and associated mathematics and reinforcing its teachings with several elementary field problems. Based on circuit theory rather than on the classical force-relationship approach, the text uses the theory of electric circuits to provide a system of experiments already familiar to the electrical engineer; a series of field concepts are then introduced as a logical extension of circuit theory. Virtually unobtainable elsewhere, this text was written by a pr

  7. Interference in ballistic motor learning - is motor interference really sensory?

    DEFF Research Database (Denmark)

    Lundbye-Jensen, Jesper; Petersen, Tue Hvass; Rothwell, John C

    Skill gained after a short period of practice in one motor task can be abolished if a second task is learned shortly afterwards. We hypothesised that interference requires the same circuits to be engaged in the two tasks and provoke competing processes of synaptic plasticity. To test this, subjects...

  8. 'Quantum interference with slits' revisited

    Science.gov (United States)

    Rothman, Tony; Boughn, Stephen

    2011-01-01

    Marcella has presented a straightforward technique employing the Dirac formalism to calculate single- and double-slit interference patterns. He claims that no reference is made to classical optics or scattering theory and that his method therefore provides a purely quantum mechanical description of these experiments. He also presents his calculation as if no approximations are employed. We show that he implicitly makes the same approximations found in classical treatments of interference and that no new physics has been introduced. At the same time, some of the quantum mechanical arguments Marcella gives are, at best, misleading.

  9. Parton showers with quantum interference

    CERN Document Server

    Nagy, Zoltan

    2007-01-01

    We specify recursive equations that could be used to generate a lowest order parton shower for hard scattering in hadron-hadron collisions. The formalism is based on the factorization soft and collinear interactions from relatively harder interactions in QCD amplitudes. It incorporates quantum interference between different amplitudes in those cases in which the interference diagrams have leading soft or collinear singularities. It incorporates the color and spin information carried by partons emerging from a hard interaction. One motivation for this work is to have a method that can naturally cooperate with next-to-leading order calculations.

  10. Parton showers with quantum interference

    International Nuclear Information System (INIS)

    Nagy, Zoltan; Soper, Davison E.

    2007-01-01

    We specify recursive equations that could be used to generate a lowest order parton shower for hard scattering in hadron-hadron collisions. The formalism is based on the factorization soft and collinear interactions from relatively harder interactions in QCD amplitudes. It incorporates quantum interference between different amplitudes in those cases in which the interference diagrams have leading soft or collinear singularities. It incorporates the color and spin information carried by partons emerging from a hard interaction. One motivation for this work is to have a method that can naturally cooperate with next-to-leading order calculations

  11. Possible health hazards for cardiac pacemaker wearers from exposure to electromagnetic fields. L'exposition aux champs electromagnetiques: Risques pour la sante des porteurs de stimulateur cardiaque

    Energy Technology Data Exchange (ETDEWEB)

    1988-03-01

    Cardiac pacemakers are used to provide electrical stimulation to the heart when the heart's natural rhythm is interrupted. This study shows that they can be susceptible to electromagnetic fields. Pacemakers are well protected against common electromagnetic fields, such as those from household appliances. But intense electomagnetic fields, such as those found in some industrial settings, could affect the functioning of the pacemaker. Such interference may cause the pacemaker wearer to feel dizzy or experience an accelerated heartbeat. While this is not fatal, the pacemaker wearer should try to move away from the source of the interfering field and avoid situations in which interference could arise. After experiencing any of these symptoms, the pacemaker wearer should contact a physician. Potential sources of electromagnetic interference should be identified and characterized to determine if there could be an interference hazard. Exposure to interfering electomagnetic fields should be minimized. 7 refs., 1 fig.

  12. Using RNA Interference to Study Protein Function

    OpenAIRE

    Curtis, Carol D.; Nardulli, Ann M.

    2009-01-01

    RNA interference can be extremely useful in determining the function of an endogenously-expressed protein in its normal cellular environment. In this chapter, we describe a method that uses small interfering RNA (siRNA) to knock down mRNA and protein expression in cultured cells so that the effect of a putative regulatory protein on gene expression can be delineated. Methods of assessing the effectiveness of the siRNA procedure using real time quantitative PCR and Western analysis are also in...

  13. Study of the Interference Affecting the Performance of the Theremin

    Directory of Open Access Journals (Sweden)

    Carmen Bachiller Martín

    2012-01-01

    Full Text Available The theremin is one of the earliest electronic musical instruments. It is named after the Russian physics Professor Lev S. Termen who invented it in 1919. This musical instrument belongs to a very short list of devices which are played without physical contact between the musician and the instrument. theremin players complain about the interference that any object in a radius of approximately 3 meters produces when playing the theremin, modifying the intonation of the instrument. This is a problem when playing in small scenarios, with other musicians which move around it. With the aim of reducing the degree of interference from nearby obstacles, some metallic isolating bars conforming an antenna array can be placed around the theremin pitch antenna. The paper shows different simulations calculated with the commercial software Ansoft HFSS, a tool which allows three-dimensional full wave electromagnetic field simulation, with radio frequencies, millimeter and micro waves, and experimental measures, both showing a reduction in the effect of the interference.

  14. Metamaterials beyond electromagnetism

    International Nuclear Information System (INIS)

    Kadic, Muamer; Bückmann, Tiemo; Schittny, Robert; Wegener, Martin

    2013-01-01

    Metamaterials are rationally designed man-made structures composed of functional building blocks that are densely packed into an effective (crystalline) material. While metamaterials are mostly associated with negative refractive indices and invisibility cloaking in electromagnetism or optics, the deceptively simple metamaterial concept also applies to rather different areas such as thermodynamics, classical mechanics (including elastostatics, acoustics, fluid dynamics and elastodynamics), and, in principle, also to quantum mechanics. We review the basic concepts, analogies and differences to electromagnetism, and give an overview on the current state of the art regarding theory and experiment—all from the viewpoint of an experimentalist. This review includes homogeneous metamaterials as well as intentionally inhomogeneous metamaterial architectures designed by coordinate-transformation-based approaches analogous to transformation optics. Examples are laminates, transient thermal cloaks, thermal concentrators and inverters, ‘space-coiling’ metamaterials, anisotropic acoustic metamaterials, acoustic free-space and carpet cloaks, cloaks for gravitational surface waves, auxetic mechanical metamaterials, pentamode metamaterials (‘meta-liquids’), mechanical metamaterials with negative dynamic mass density, negative dynamic bulk modulus, or negative phase velocity, seismic metamaterials, cloaks for flexural waves in thin plates and three-dimensional elastostatic cloaks. (review article)

  15. Metamaterials beyond electromagnetism

    Science.gov (United States)

    Kadic, Muamer; Bückmann, Tiemo; Schittny, Robert; Wegener, Martin

    2013-12-01

    Metamaterials are rationally designed man-made structures composed of functional building blocks that are densely packed into an effective (crystalline) material. While metamaterials are mostly associated with negative refractive indices and invisibility cloaking in electromagnetism or optics, the deceptively simple metamaterial concept also applies to rather different areas such as thermodynamics, classical mechanics (including elastostatics, acoustics, fluid dynamics and elastodynamics), and, in principle, also to quantum mechanics. We review the basic concepts, analogies and differences to electromagnetism, and give an overview on the current state of the art regarding theory and experiment—all from the viewpoint of an experimentalist. This review includes homogeneous metamaterials as well as intentionally inhomogeneous metamaterial architectures designed by coordinate-transformation-based approaches analogous to transformation optics. Examples are laminates, transient thermal cloaks, thermal concentrators and inverters, ‘space-coiling’ metamaterials, anisotropic acoustic metamaterials, acoustic free-space and carpet cloaks, cloaks for gravitational surface waves, auxetic mechanical metamaterials, pentamode metamaterials (‘meta-liquids’), mechanical metamaterials with negative dynamic mass density, negative dynamic bulk modulus, or negative phase velocity, seismic metamaterials, cloaks for flexural waves in thin plates and three-dimensional elastostatic cloaks.

  16. The basis of electromagnetism

    International Nuclear Information System (INIS)

    Waldron, R.A.

    1980-01-01

    Observations on fast mesons in cyclotrons have necessitated a revision of the earlier version of the ballistic theory. Insufficient information was available when the theory was first published to permit a unique choice of the velocity-dependent factors occurring in electromagnetic force formulas, and the forms chosen did not lead to an explanation of the decay times of fast mesons that were observed subsequently. These observations provide the information needed to permit a unique choice of the velocity-dependent factors. The new forms of the force formulae explain all observations, and lead to the conclusion that the velocities of mesons in cyclotrons are many times that of light. If these velocities could be directly measured, it would provide a method of discriminating between the Lorentz-Einstein and the ballistic theories, although it would not confirm the latter. In this revised form of the theory, magnetism appears as a residual effect of the velocity dependence of electric force laws, and the whole of electromagnetism then follows from a single basic equation, a modified form of Coulomb's law. (Auth.)

  17. Electro-magnetic flowmeters

    International Nuclear Information System (INIS)

    Dean, S.A.

    1980-01-01

    Full details of the invention are given. A sensing unit assembly for an electromagnetic flux distortion flowmeter for use in liquid metal coolant of a nuclear reactor is described. The assembly comprises coils of electrically insulated conductors each wound on an individual former. The formers and coils are mounted coaxially on a spine to form at least three spaced groups arranged end to end. Each group comprises two secondary coils and an intermediate primary coil. Leads extend along a duct formed in the spine, each lead terminating at a common end. Alternative versions of the assembly are also described. The primary coil leads are connected to an alternating power supply; those for the secondary coils connected to suitable display instrumentation. When liquid metal flows along the conductor the electromagnetic field is disturbed and the induced voltage in the secondary coils is disturbed-(set at zero for no flow); the distortion depends on the rate of flow. When the induced voltage differential of at least two of the groups falls or rises outside a pre-set level a trip signal is initiated to shut down the reactor. (UK)

  18. The effects of annealing temperature on the permittivity and electromagnetic attenuation performance of reduced graphene oxide

    Science.gov (United States)

    Wu, Fan; Zeng, Qiao; Xia, Yilu; Sun, Mengxiao; Xie, Aming

    2018-05-01

    Reduced graphene oxide (RGO) has been prepared through the thermal reduction method with different annealing temperatures to explore the effects of temperature on the permittivity and electromagnetic attenuation performance. The real and imaginary parts of permittivity increase along with the decrease in the oxygen functional group and the increase in the filler loading ratio. A composite only loaded with 1 wt. % of RGO can possess an effective electromagnetic absorption bandwidth of 7.60 GHz, when graphene oxide was reduced under 300 °C for 2 h. With the annealing temperature increased to 700 °C and the well reduced RGO loaded 7 wt. % in the composite, the electromagnetic interference shielding efficiency can get higher than 35 dB from 2 to 18 GHz. This study shows that controlling the oxygen functional groups on the RGO surface can also obtain an ideal electromagnetic attenuation performance without any other decorated nanomaterials.

  19. [INVITED] Coherent perfect absorption of electromagnetic wave in subwavelength structures

    Science.gov (United States)

    Yan, Chao; Pu, Mingbo; Luo, Jun; Huang, Yijia; Li, Xiong; Ma, Xiaoliang; Luo, Xiangang

    2018-05-01

    Electromagnetic (EM) absorption is a common process by which the EM energy is transformed into other kinds of energy in the absorber, for example heat. Perfect absorption of EM with structures at subwavelength scale is important for many practical applications, such as stealth technology, thermal control and sensing. Coherent perfect absorption arises from the interplay of interference and absorption, which can be interpreted as a time-reversed process of lasing or EM emitting. It provides a promising way for complete absorption in both nanophotonics and electromagnetics. In this review, we discuss basic principles and properties of a coherent perfect absorber (CPA). Various subwavelength structures including thin films, metamaterials and waveguide-based structures to realize CPAs are compared. We also discuss the potential applications of CPAs.

  20. Observation of electromagnetically induced Talbot effect in an atomic system

    Science.gov (United States)

    Zhang, Zhaoyang; Liu, Xing; Zhang, Dan; Sheng, Jiteng; Zhang, Yiqi; Zhang, Yanpeng; Xiao, Min

    2018-01-01

    The electromagnetically induced Talbot effect (EITE) resulting from the repeated self-reconstruction of a spatially intensity-modulated probe field is experimentally demonstrated in a three-level atomic configuration. The probe beam is launched into an optically induced lattice (established by the interference of two coupling fields) inside a rubidium vapor cell and is diffracted by the electromagnetically induced grating that was formed. The diffraction pattern repeats itself at the planes of integer multiple Talbot lengths. In addition, a fractional EITE is also investigated. The experimental observations agree well with the theoretical predictions. This investigation may potentially pave the way for studying the nonlinear and quantum dynamical features that have been predicted for established periodic optical systems.