WorldWideScience

Sample records for electrocardiography ecg-triggering comparison

  1. Comparison between retrospective gating and ECG triggering in magnetic resonance velocity mapping

    DEFF Research Database (Denmark)

    Søndergaard, L; Ståhlberg, F; Thomsen, C

    1993-01-01

    ECG-triggered cinematographic studies of the cardiovascular system are hampered by several technical restrictions such as the inability to image end-diastole, ghosting, varying signal intensity, and phase contributions from eddy currents. Retrospective gating may solve these problems, but involves...... of flow pulses. However, by reducing the time window retrospectively gated flow measurements were in good agreement with those that are ECG triggered. When fulfilling the demand of a narrow time window for interpolation, retrospective gating offers several advantages in MR velocity mapping....

  2. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  3. ECG-triggered MDR-CT for the detection of pulmonary metastases

    International Nuclear Information System (INIS)

    Pauls, S.; Wahl, J.; Aschoff, A.J.; Brambs, H.J.; Fleiter, T.R.

    2003-01-01

    Purpose: Comparison of multidetector-row CT (MDR-CT) of the chest with and without ECG triggering for the detection of pulmonary metastases. Materials and Methods: Fifty patients with malignant tumors underwent CT of the chest. The unenhanced phase was performed with ECG-triggered MDR-CT and the contrast-enhanced phase with helical MDR-CT. The ECG-triggered and standard helical scans were interpreted in separate sessions, with the analysis determining the number and demarcation of the intrapulmonary nodules and the delineation of the mediastinal structure (rated 1 = excellent to 5 = poor). Results: ECG-MDR-CT images detected 38% more pulmonary nodules than MDR-CT. The detection rate for tumors [de

  4. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Zhou, Chang Sheng; Zhao, Yan E.; Li, Xie; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Wang, Yining; Cao, Jian; Jin, Zhengyu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Schoepf, U.J. [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Meinel, Felix G. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Gong, Jian Bin [Jinling Hospital, Medical School of Nanjing University, Department of Cardiology, Nanjing, Jiangsu (China)

    2016-03-15

    To investigate image quality, radiation dose, and diagnostic performance of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp compared to invasive coronary angiography (ICA) as reference standard. Forty-three patients underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp using 30 cc (11 g iodine) contrast medium and ICA. Subjective and objective image quality was evaluated for each CCTA study. CCTA performance for diagnosing ≥50 % stenosis was assessed. Results were stratified according to heart rate (HR), body mass index (BMI), Agatston score, and image quality. At CCTA, 94.3 % (500/530) of coronary segments were of diagnostic quality. Using ICA as reference standard, sensitivity and accuracy were 100 % and 93.0 % on a per-patient basis. Per-vessel and per-segment performances were 92.2 % and 89.5 %; 79.5 % and 88.3 %, respectively. No differences were found in diagnostic accuracy between different HR, BMI, and calcification subgroups (all P > 0.05) on a per-patient basis. However, low image quality reduced diagnostic accuracy on a per-patient, per-vessel and per-segment basis (all P < 0.05). The mean effective radiation dose was 0.2 ± 0.0 mSv. Our presented protocol results in an effective radiation dose of 0.2 mSv and high diagnostic accuracy for stenosis detection in a selected, non-obese population. (orig.)

  5. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor [University Hospital Freiburg, Department of Diagnostic Radiology, Freiburg (Germany)

    2010-08-15

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 {+-} 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI (<25 kg/m{sup 2}: 100 kV, >25 kg/m{sup 2}: 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 {+-} 11.1 bpm, variability 1.0 {+-} 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 {+-} 16.6 bpm, variability 17.9 {+-} 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 {+-} 0.3 and 3.0 {+-} 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  6. Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography

    International Nuclear Information System (INIS)

    Blanke, Philipp; Baumann, Tobias; Langer, Mathias; Pache, Gregor

    2010-01-01

    To prospectively investigate the feasibility, image quality and radiation dose estimates for computed tomography angiography (CTA) of the pulmonary veins and left atrium using prospective electrocardiography (ECG)-triggered sequential dual-source (DS) data acquisition at end-systole in patients with paroxysmal atrial fibrillation undergoing radiofrequency ablation. Thirty-five patients (mean age 66.2 ± 12.6 years) with paroxysmal atrial fibrillation underwent prospective ECG-triggered sequential DS-CTA with tube current (250 mAs/rotation) centred 250 ms past the R-peak. Tube voltage was adjusted to the BMI ( 2 : 100 kV, >25 kg/m 2 : 120 kV). Presence of motion or stair-step artefacts was assessed. Effective radiation dose was calculated from the dose-length product. All data sets could be integrated into the electroanatomical mapping system. Twenty-two patients (63%) were in sinus rhythm (mean heart rate 69.2 ± 11.1 bpm, variability 1.0 ± 1.7 bpm) and 13 (37%) showed an ECG pattern of atrial fibrillation (mean heart rate 84.8 ± 16.6 bpm, variability 17.9 ± 7.5 bpm). Minor step artefacts were observed in three patients (23%) with atrial fibrillation. Mean estimated effective dose was 1.1 ± 0.3 and 3.0 ± 0.5 mSv for 100 and 120 kV respectively. Imaging of pulmonary vein anatomy is feasible using prospective ECG-triggered sequential data acquisition at end-systole regardless of heart rate or rhythm at the benefit of low radiation dose. (orig.)

  7. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  8. Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

    International Nuclear Information System (INIS)

    Pontone, G.; Andreini, D.; Bartorelli, A.L.; Bertella, E.; Mushtaq, S.; Foti, C.; Formenti, A.; Chiappa, L.; Annoni, A.; Cortinovis, S.; Baggiano, A.; Conte, E.; Bovis, F.; Veglia, F.; Ballerini, G.; Agostoni, P.; Fiorentini, C.; Pepi, M.

    2012-01-01

    Aim: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients’ heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 ± 3.9 versus 14.2 ± 4.1, 16 ± 4.6 versus 16.5 ± 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 ± 1.2 versus 7.5 ± 1.8 mSv, respectively; p < 0.01). Conclusions: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.

  9. Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pontone, G., E-mail: gianluca.pontone@ccfm.it [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Andreini, D. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Bartorelli, A.L. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Department of Cardiovascular Sciences, University of Milan, Milan (Italy); Bertella, E.; Mushtaq, S.; Foti, C.; Formenti, A.; Chiappa, L.; Annoni, A.; Cortinovis, S.; Baggiano, A.; Conte, E.; Bovis, F.; Veglia, F.; Ballerini, G. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Agostoni, P.; Fiorentini, C. [Centro Cardiologico Monzino, IRCCS, Milan (Italy); Department of Cardiovascular Sciences, University of Milan, Milan (Italy); Pepi, M. [Centro Cardiologico Monzino, IRCCS, Milan (Italy)

    2012-03-15

    Aim: To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2). Materials and methods: One hundred and seventy patients scheduled for invasive coronary angiography (ICA) were evaluated. Fourteen patients were not eligible for MDCT. The remaining 156 patients were randomized to group 1 (78 patients) and group 2 (78 patients). Eight and 11 patients in groups 1 and 2, respectively, were excluded after randomization because the patients' heart rates were >65 beats/min. MDCT images were assessed for feasibility, signal-to-noise ration (SNR), and contrast-to-noise ratio (CNR), accuracy in detection of coronary stenoses >50% versus ICA and for ED. Results: The feasibility, SNR, CNR, accuracy in a segment-based and patient-based model were similar in both groups (97 versus 95%, 14.5 {+-} 3.9 versus 14.2 {+-} 4.1, 16 {+-} 4.6 versus 16.5 {+-} 4.4, 95 versus 94% and 97 versus 99%, respectively). The ED in group 1 was 72% lower than in group 2 (2.1 {+-} 1.2 versus 7.5 {+-} 1.8 mSv, respectively; p < 0.01). Conclusions: The use of a multi-parametric ED saving protocol results in a significant reduction in ED without a negative impact on accuracy.

  10. Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT

    International Nuclear Information System (INIS)

    Xue Yuejun; Qian Nong; Shao Yanhui; Pan Changjie; Rong Weiliang; Xu Yiqun

    2012-01-01

    Objective: To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot, SAS). Methods: A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot, SAS). Data acquisition was at 60% R-R interval of the ECG presentation mode. The post-processing included maximum intensity projection (MIP), multiplanar reformation (MPR) and volume rendering (VR). The CTA image quality, radiation dose and rates of excellent images were evaluated. Results: The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images. The average effective dose of SAS-CTA was (0.22 ± 0.01)mSv, which was lower by 76.31% than that of DE-CTA. Conclusions: Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality. (authors)

  11. Assessment of maximal myocardial perfusion by ECG-triggered digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pijls, N.H.J.; Uijen, G.J.H.; Werf, T. van der (Katholieke Univ. Nijmegen (Netherlands). Cardiology Dept.)

    1991-01-01

    Early studies about calculation of coronary blood flow by analysis of contrast agent passage on the coronary arteriogram were reported more than 2 decades ago by Rutishauser et al. and Smith et al. Thereafter is was shown that visualization of contrast passage through the myocardium could be enhanced by ECG-triggered digital subtraction imaging and it was suggested that myocardial flow could be calculated by studying the temporal changes in contrast intensity in a myocardial region of interest (ROI) as a function of time: the time density curve (TDC). (orig./GDG).

  12. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Luecke, Christian, E-mail: neep@gmx.de [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Andres, Claudia; Foldyna, Borek [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany); Nagel, Hans Dieter [Wissenschaft and Technik für die Radiologie, Buchhholz i.d.N (Germany); Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas [University of Leipzig – Heart Center, Department of Diagnostic and Interventional Radiology, Strümpellstrasse 39, D-04289, Leipzig (Germany)

    2012-09-15

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p < 0.05) were bifocal pacemaker (61%), pacemaker dysfunction (22%), SVES (20%), ventricular salvo (20%), and atrial fibrillation (14%). Significantly (p < 0.05) prolonged scan time (>8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols.

  13. Impact of heart rate and rhythm on radiation exposure in prospectively ECG triggered computed tomography

    International Nuclear Information System (INIS)

    Luecke, Christian; Andres, Claudia; Foldyna, Borek; Nagel, Hans Dieter; Hoffmann, Janine; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Lehmkuhl, Lukas

    2012-01-01

    Purpose: To evaluate the influence of different heart rates and arrhythmias on scanner performance, image acquisition and applied radiation exposure in prospectively ECG triggered computed tomography (pCT). Materials and methods: An ECG simulator (EKG Phantom 320, Müller and Sebastiani Elektronik GmbH, Munich, Germany) was used to generate different heart rhythms and arrhythmias: sinus rhythm (SR) at 45, 60, 75, 90 and 120/min, supraventricular arrhythmias (e.g. sinus arrhythmia, atrial fibrillation) and ventricular arrhythmias (e.g. ventricular extrasystoles), pacemaker-ECGs, ST-changes and technical artifacts. The analysis of the image acquisition process was performed on a 64-row multidetector CT (Brilliance, Philips Medical Systems, Cleveland, USA). A prospectively triggered scan protocol as used for routine was applied (120 kV; 150 mA s; 0.4 s rotation and exposure time per scan; image acquisition predominantly in end-diastole at 75% R-R-interval, in arrythmias with a mean heart rate above 80/min in systole at 45% of the R-R-interval; FOV 25 cm). The mean dose length product (DLP) and its percentage increase from baseline (SR at 60/min) were determined. Result: Radiation exposure can increase significantly when the heart rhythm deviates from sinus rhythm. ECG-changes leading to a significant DLP increase (p 8 s) could be observed in bifocal pacemaker (12.8 s), pacemaker dysfunction (10.7 s), atrial fibrillation (10.3 s) and sinus arrhythmia (9.3 s). Conclusion: In prospectively ECG triggered CT, heart rate and rhythm can provoke different types of scanner performance, which can significantly alter radiation exposure and scan time. These results might have an important implication for indication, informed consent and contrast agent injection protocols

  14. Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience

    International Nuclear Information System (INIS)

    Wang, Q.; Qin, J.; He, B.; Zhou, Y.; Yang, J.-J.; Hou, X.-L.; Yang, X.-B.; Chen, J.-H.; Chen, Y.-D.

    2013-01-01

    Aim: To evaluate the feasibility of double prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition mode (double high-pitch mode) for coronary computed tomography angiography (CTCA). Materials and methods: One hundred and forty-nine consecutive patients [40 women, 109 men; mean age 58.2 ± 9.2 years; sinus rhythm ≤70 beats/min (bpm) after pre-medication, body weight ≤100 kg] were enrolled for CTCA examinations using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, and a pitch of 3.4. Double high-pitch mode was prospectively triggered first at 60% and later at 30% of the R–R interval within two cardiac cycles. Image quality was evaluated using a four-point scale (1 = excellent, 4 = non-assessable). Results: From 2085 coronary artery segments, 86.4% (1802/2085) were rated as having a score of 1, 12.3% (257/2085) as score of 2, 1.2% (26/2085) as score of 3, and none were rated as “non-assessable”. The average image quality score was 1.15 ± 0.26 on a per-segment basis. The effective dose was calculated by multiplying the coefficient factor of 0.028 by the dose–length product (DLP); the mean effective dose was 3.5 ± 0.8 mSv (range 1.7–7.6 mSv). The total dosage of contrast medium was 78.7 ± 2.9 ml. Conclusion: Double prospectively ECG-triggered high-pitch spiral acquisition mode provides good image quality with an average effective dose of less than 5 mSv in patients with a heart rate ≤70 bpm

  15. Comparison of exercise electrocardiography and quantitative thallium imaging for one-vessel coronary artery disease

    International Nuclear Information System (INIS)

    Kaul, S.; Kiess, M.; Liu, P.; Guiney, T.E.; Pohost, G.M.; Okada, R.D.; Boucher, C.A.

    1985-01-01

    The relative value of exercise electrocardiography and computer analyzed thallium-201 imaging was compared in 124 patients with 1-vessel coronary artery disease (CAD). Of these, 78 had left anterior descending (LAD), 32 right and 14 left circumflex (LC) CAD. In patients with no previous myocardial infarction (MI), thallium imaging was more sensitive than the electrocardiogram (78% vs 64%, p less than 0.01), but in patients with previous MI, sensitivity was similar. Further, thallium imaging was more sensitive only in LAD and LC disease. Redistribution was compared with ST-segment depression as a marker of ischemia. Only in patients with prior MI (76% vs 44%, p less than 0.01) and only in LC and right CAD did redistribution occur more often than ST depression. Thallium imaging was more accurate in localizing stenoses than the electrocardiogram (p less than 0.001), but did not always correctly predict coronary anatomy. Septal thallium defects were associated with LAD disease in 84%, inferior defects with right CAD in 40% and posterolateral lesion defects with LC CAD in 22%. The results indicate the overall superiority of thallium imaging in 1-vessel CAD compared with exercise electrocardiography; however, there is a wide spectrum of extent and location of perfusion defects associated with each coronary artery. Thallium imaging complements coronary angiography by demonstrating the functional impact of CAD on myocardial perfusion

  16. The optimal dose reduction level using iterative reconstruction with prospective ECG-triggered coronary CTA using 256-slice MDCT

    International Nuclear Information System (INIS)

    Hou, Yang; Xu, Shu; Guo, Wenli; Vembar, Mani; Guo, Qiyong

    2012-01-01

    Aim: To assess the image quality (IQ) of an iterative reconstruction (IR) technique (iDose 4 ) from prospective electrocardiography (ECG)-triggered coronary computed tomography angiography (coronary CTA) on a 256-slice multi-detector CT (MDCT) scanner and determine the optimal dose reduction using IR that can provide IQ comparable to filtered back projection (FBP). Method and materials: 110 consecutive patients (69 men, 41 women; age: 54 ± 10 years) underwent coronary CTA on a 256-slice MDCT (Brilliance iCT, Philips Healthcare). The control group (Group A, n = 21) were scanned using the conventional tube output (120 kVp, 210 mAs) and reconstructed using FBP. The other 4 groups were scanned with the same kVp but successively reduced tube output as follows: B[n = 15]: 125 mAs; C[n = 22]: 105 mAs; D[n = 36]: 84 mAs: E[n = 16]: 65 mAs) and reconstructed using IR levels of L3 (Group B), L4 (Group C) and L5 (Groups D and E), to compensate for the noise increase. All images were reconstructed using the same kernel (XCB). Two radiologists graded IQ in a blinded fashion on a 4-point scale (4 – excellent, 3 – good, 2 – fair and 1 – poor). Quantitative measurements of CT values, image noise and contrast-to-noise (CNR) were measured in each group. A receiver-operating characteristic (ROC) analysis was performed to determine a radiation reduction threshold up to which excellent IQ was maintained. Results: There were no significant differences in objective noise, SNR and CNR values among Groups A, B, C, D, and E (P = 0.14, 0.09, 0.17, respectively). There were no significant differences in the scores of the subjective IQ between Group A, and Groups B, C, D, E (P = 0.23–0.97). Significant differences in image sharpness and study acceptability were observed between groups A and E (P < 0.05). Using the criterion of excellent IQ (score 4), the ROC curve of dose levels and IQ acceptability established a reduction of 60% of tube output (Group D) as optimum cutoff point (AUC

  17. Effects of electrocardiography contamination and comparison of ECG removal methods on upper trapezius electromyography recordings.

    Science.gov (United States)

    Marker, Ryan J; Maluf, Katrina S

    2014-12-01

    Electromyography (EMG) recordings from the trapezius are often contaminated by the electrocardiography (ECG) signal, making it difficult to distinguish low-level muscle activity from muscular rest. This study investigates the influence of ECG contamination on EMG amplitude and frequency estimations in the upper trapezius during muscular rest and low-level contractions. A new method of ECG contamination removal, filtered template subtraction (FTS), is described and compared to 30 Hz high-pass filter (HPF) and averaged template subtraction (ATS) methods. FTS creates a unique template of each ECG artifact using a low-pass filtered copy of the contaminated signal, which is subtracted from contaminated periods in the original signal. ECG contamination results in an over-estimation of EMG amplitude during rest in the upper trapezius, with negligible effects on amplitude and frequency estimations during low-intensity isometric contractions. FTS and HPF successfully removed ECG contamination from periods of muscular rest, yet introduced errors during muscle contraction. Conversely, ATS failed to fully remove ECG contamination during muscular rest, yet did not introduce errors during muscle contraction. The relative advantages and disadvantages of different ECG contamination removal methods should be considered in the context of the specific motor tasks that require analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Comparison of Left Ventricular Hypertrophy by Electrocardiography and Echocardiography in Children Using Analytics Tool.

    Science.gov (United States)

    Tague, Lauren; Wiggs, Justin; Li, Qianxi; McCarter, Robert; Sherwin, Elizabeth; Weinberg, Jacqueline; Sable, Craig

    2018-05-17

    Left ventricular hypertrophy (LVH) is a common finding on pediatric electrocardiography (ECG) leading to many referrals for echocardiography (echo). This study utilizes a novel analytics tool that combines ECG and echo databases to evaluate ECG as a screening tool for LVH. SQL Server 2012 data warehouse incorporated ECG and echo databases for all patients from a single institution from 2006 to 2016. Customized queries identified patients 0-18 years old with LVH on ECG and an echo performed within 24 h. Using data visualization (Tableau) and analytic (Stata 14) software, ECG and echo findings were compared. Of 437,699 encounters, 4637 met inclusion criteria. ECG had high sensitivity (≥ 90%) but poor specificity (43%), and low positive predictive value (< 20%) for echo abnormalities. ECG performed only 11-22% better than chance (AROC = 0.50). 83% of subjects with LVH on ECG had normal left ventricle (LV) structure and size on echo. African-Americans with LVH were least likely to have an abnormal echo. There was a low correlation between V 6 R on ECG and echo-derived Z score of left ventricle diastolic diameter (r = 0.14) and LV mass index (r = 0.24). The data analytics client was able to mine a database of ECG and echo reports, comparing LVH by ECG and LV measurements and qualitative findings by echo, identifying an abnormal LV by echo in only 17% of cases with LVH on ECG. This novel tool is useful for rapid data mining for both clinical and research endeavors.

  19. Calcium scoring with prospectively ECG-triggered CT: Using overlapping datasets generated with MPR decreases inter-scan variability

    International Nuclear Information System (INIS)

    Rutten, A.; Isgum, I.; Prokop, M.

    2011-01-01

    Objective: To examine the feasibility of reducing the inter-scan variability of prospectively ECG-triggered calcium-scoring scans by using overlapping 3-mm datasets generated from multiplanar reformation (MPR) instead of non-overlapping 3-mm or 1.5-mm datasets. Patients and methods: Seventy-five women (59-79 years old) underwent two sequential prospectively ECG-triggered calcium-scoring scans with 16 mm x 1.5 mm collimation in one session. Between the two scans patients got off and on the table. We performed calcium scoring (Agatston and mass scores) on the following datasets: contiguous 3-mm sections reconstructed from the raw data (A), contiguous 3-mm sections from MPR (B), overlapping 3-mm sections from MPR (C) and contiguous 1.5-mm sections from the raw data (D). To determine the feasibility of the MPR approach, we compared MPR (B) with direct raw data reconstruction (A). Inter-scan variability was calculated for each type of dataset (A-D). Results: Calcium scores ranged from 0 to 1455 (Agatston) and 0 to 279 mg (mass) for overlapping 3-mm sections (C). Calcium scores (both Agatston and mass) were nearly identical for MPR (B) and raw data approaches (A), with inter-quartile ranges of 0-1% for inter-scan variability. Median inter-scan variability with contiguous 3-mm sections (B) was 13% (Agatston) and 11% (mass). Median variability was reduced to 10% (Agatston and mass) with contiguous 1.5-mm sections (D) and to 8% (Agatston) and 7% (mass) with overlapping 3-mm MPR (A). Conclusion: Calcium scoring on MPR yields nearly identical results to calcium scoring on images directly reconstructed from raw data. Overlapping MPR from prospectively ECG-triggered scans improve inter-scan variability of calcium scoring without increasing patient radiation dose.

  20. Electrocardiography-triggered high-resolution CT for reducing cardiac motion artifact. Evaluation of the extent of ground-glass attenuation in patients with idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Nishiura, Motoko; Johkoh, Takeshi; Yamamoto, Shuji

    2007-01-01

    The aim of this study was to evaluate the decreasing of cardiac motion artifact and whether the extent of ground-glass attenuation of idiopathic pulmonary fibrosis (IPF) was accurately assessed by electrocardiography (ECG)-triggered high-resolution computed tomography (HRCT) by 0.5-s/rotation multidetector-row CT (MDCT). ECG-triggered HRCT were scanned at the end-diastolic phase by a MDCT scanner with the following scan parameters; axial four-slice mode, 0.5 mm collimation, 0.5-s/rotation, 120 kVp, 200 mA/rotation, high-frequency algorithm, and half reconstruction. In 42 patients with IPF, both conventional HRCT (ECG gating (-), full reconstruction) and ECG-triggered HRCT were performed at the same levels (10-mm intervals) with the above scan parameters. The correlation between percent diffusion of carbon monoxide of the lung (%DLCO) and the mean extent of ground-glass attenuation on both conventional HRCT and ECG-triggered HRCT was evaluated with the Spearman rank correlation coefficient test. The correlation between %DLCO and the mean extent of ground-glass attenuation on ECG-triggered HRCT (observer A: r=-0.790, P<0.0001; observer B: r=-0.710, P<0.0001) was superior to that on conventional HRCT (observer A: r=-0.395, P<0.05; observer B: r=-0.577, P=0.002) for both observers. ECG-triggered HRCT by 0.5 s/rotation MDCT can reduce the cardiac motion artifact and is useful for evaluating the extent of ground-glass attenuation of IPF. (author)

  1. Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imagining slabs in free-breathing children: Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Allmendinger, Thomas [Siemens Healthcare, GmbH, Computed Tomography Division, Forchheim (Germany)

    2017-09-15

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children.

  2. Combined electrocardiography- and respiratory-triggered CT of the lung to reduce respiratory misregistration artifacts between imagining slabs in free-breathing children: Initial experience

    International Nuclear Information System (INIS)

    Goo, Hyun Woo; Allmendinger, Thomas

    2017-01-01

    Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. In total, 15 children (median age 19 months, range 6 months–8 years; 7 boys), who underwent free-breathing ECG-triggered lung CT with and without respiratory-triggering were included. A pressure-sensing belt of a respiratory gating system was used to obtain the respiratory signal. The degree of respiratory misregistration artifacts between imaging slabs was graded on a 4-point scale (1, excellent image quality) on coronal and sagittal images and compared between ECG-triggered lung CT studies with and without respiratory triggering. A p value < 0.05 was considered significant. Lung CT with combined ECG and respiratory triggering showed significantly less respiratory misregistration artifacts than lung CT with ECG triggering only (1.1 ± 0.4 vs. 2.2 ± 1.0, p = 0.003). Additional respiratory-triggering reduces respiratory misregistration artifacts on ECG-triggered lung CT in free-breathing children

  3. Comparison of exercise electrocardiography and stress perfusion CMR for the detection of coronary artery disease in women

    Directory of Open Access Journals (Sweden)

    Greulich Simon

    2012-06-01

    Full Text Available Abstract Background Exercise electrocardiography (ECG is frequently used in the work-up of patients with suspected coronary artery disease (CAD, however the accuracy is reduced in women. Cardiovascular magnetic resonance (CMR stress testing can accurately diagnose CAD in women. To date, a direct comparison of CMR to ECG has not been performed. Methods and results We prospectively enrolled 88 consecutive women with chest pain or other symptoms suggestive of CAD. Patients underwent a comprehensive clinical evaluation, exercise ECG, a CMR stress test including perfusion and infarct imaging, and x-ray coronary angiography (CA within 24 hours. CAD was defined as stenosis ≥70% on quantitative analysis of CA. Exercise ECG, CMR and CA was completed in 68 females (age 66.4 ± 8.8 years, number of CAD risk factors 3.5 ± 1.4. The prevalence of CAD on CA was 29%. The Duke treadmill score (DTS in the entire group was −3.0 ± 5.4 and was similar in those with and without CAD (−4.5 ± 5.8 and −2.4 ± 5.1; P = 0.12. Sensitivity, specificity and accuracy for CAD diagnosis was higher for CMR compared with exercise ECG (sensitivities 85% and 50%, P = 0.02, specificities 94% and 73%, P = 0.01, and accuracies 91% and 66%, P = 0.0007, respectively. Even after applying the DTS the accuracy of CMR was higher compared to exercise ECG (area under ROC curve 0.94 ± 0.03 vs 0.56 ± 0.07; P = 0.0001. Conclusions In women with intermediate-to-high risk for CAD who are able to exercise and have interpretable resting ECG, CMR stress perfusion imaging has higher accuracy for the detection of relevant obstruction of the epicardial coronaries when directly compared to exercise ECG.

  4. Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.

    Science.gov (United States)

    Gao, Wei; Zhong, Yu Min; Sun, Ai Min; Wang, Qian; Ouyang, Rong Zhen; Hu, Li Wei; Qiu, Han Sheng; Wang, Shi Yu; Li, Jian Ying

    2016-06-01

    To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.

  5. Clinical usefullness of ECG-triggered single photon emission comuter tomography of blood-pool

    International Nuclear Information System (INIS)

    Eilles, Chr.; Boerner, W.; Strauss, P.; Gerhards, W.; Reiners, Ch.

    1982-01-01

    ECT allows direct measurement of the volume of an organ and imaging without disturbing background-superposition. This makes ECT to an useful instrument for ECG-gated blood-pool imaging. Acquisition is made after the injection of 25 mCi Tc-99m HSA with a rotating Anger-Camera-System. ECG-gated imaging is done for each projection; herewith 50-70 cycles per projection are added according to the phase of the heart-cycle. Transversal-Sections of the heart are reconstructed with filtered-back-projection. For each slice a representative cycle, consisting of 10-16 frames, is computed. As shown by our group before a good quality of the reconstructed images can be obtained. Comparison is made with the results of the ECG-gated blood-pool-ECT, the results of the conventional blood-pool-studies and with the results of Laevo-Cardiography. (Author)

  6. Comparison of the measurement of heart rate in adult free-range chickens (Gallus domesticus) by auscultation and electrocardiography.

    Science.gov (United States)

    Smith, C F; Gavaghan, B J; McSweeney, D; Powell, V; Lisle, A

    2014-12-01

    To compare the heart rates of adult free-range chickens (Gallus domesticus) measured by auscultation with a stethoscope with those measured simultaneously using electrocardiography (ECG). With each bird in a standing position, estimation of the heart rate was performed by placing a mark on paper for every 4 beats for roosters and 8 beats for hens as detected by auscultation over 30 s, while simultaneous ECG was performed. Heart rates measured by auscultation showed a high correlation (r = 0.97) with those measured by ECG. There was a high correlation between the heart rates of adult free-range chickens measured by auscultation with a stethoscope and those measured simultaneously using ECG. © 2014 Australian Veterinary Association.

  7. Detection of exercise induced ischemia in the asymptomatic recent post myocardial infarction patient: comparison of stress electrocardiography and radionuclide angiography

    International Nuclear Information System (INIS)

    Jengo, J.A.; Brizendine, M.; Dykstra, L.; Sweet, J.; Bruno, M.; Garcia, A.

    1982-01-01

    The purpose of this study was to compare the techniques of low level stress electrocardiography and radionuclide angiographic wall motion analysis for the detection of new areas of myocardial ischemia in the asymptomatic recent post-myocardial infarction patient. The protocol consisted of obtaining a resting, RAO upright first pass radionuclide angiocardiogram using 15 mCi of 99m technetium-DTPA. The study suggests that assessment of segmental wall motion during low level stress can detect areas of myocardium at high risk either intermixed with or in addition to recently infarcted areas in the asymptomatic post-infarction patient, which are not detected by ECG. This high risk subset of patients can then be observed or treated in a more vigorous manner. This technique allows for not only the identification of additional areas of myocardium at jeopardy but also provides information regarding the severity of ischemic dysfunction, an important prognostic and therapeutic factor

  8. Comparison of electron beam computed tomography and exercise electrocardiography in detecting coronary artery disease in the elderly

    International Nuclear Information System (INIS)

    Inoue, Shinji; Mitsunami, Kenichi; Kinoshita, Masahiko

    1998-01-01

    Although exercise electrocardiography (ECG) is a useful noninvasive screening test for coronary artery disease (CAD), one prerequisite for ECG screening is that patient be able to exercise enough to evoke myocardial ischemia. Thus, exercise ECG may not be suitable for, some elderly people with CAD who cannot exercise enough. We compared electron beam Computed Tomography (EBCT) with exercise ECG for detecting CAD in 196 patients (mean age, 58.4±12.5 (standard deviation)) who had undergone coronary angiography. Using the angiographic findings as the ''gold standard'', we found that the sensitivity, specificity, positive predictive value, and negative predictive value were 88%, 77%, 89%, and 77%, respectively, for EBCT, and 66%, 72%, 83%, and 52%, respectively, for exercise ECG. Although the results were similar when the subjects were divided into different age groups, the negative predictive value for exercise ECG, among older patients was very low. These findings suggest that EBCT is superior to exercise ECG in detecting CAD in the elderly. (author)

  9. Myocardial imaging with 201Tl at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography

    International Nuclear Information System (INIS)

    Ritchie, J.L.; Trobaugh, G.B.; Hamilton, G.W.; Gould, K.L.; Narahara, K.A.; Murray, J.A.; Williams, D.L.

    1977-01-01

    Myocardial imaging with intravenous thallium-201 ( 201 Tl) was performed at rest and following maximal treadmill exercise in 101 patients with suspected coronary artery disease. Results were interpreted from Polaroid scintiphotos by three independent observers with complete interobserver agreement in 79%. Of 25 patients with no or insignificant coronary artery disease ( 201 Tl image defect, one (4%) had an exercise 201 Tl defect, none had an ECG Q wave, and four (16%) had exercise ST-segment depression. Among 76 patients with coronary artery disease (greater than or equal to 50% diameter stenosis), 58 (76%) had a defect on either the rest or exercise 201 Tl image. The proportion of patients with an exercise image defect (50/76, 66%) was greater than the proportion with exercise ST depression alone (34/76, 45%; P 201 Tl is easily accomplished with readily available imaging equipment. The image data enhanced the diagnostic sensitivity of stress electrocardiography, and provided spatial identification of the abnormal segment(s) of myocardium

  10. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Tang, Chun Xiang; Zhou, Chang Sheng; Ji, Xue Man; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Wang, Jing [Medical School of Nanjing University, Department of Cardiology, Jinling Hospital, Nanjing, Jiangsu (China); Spearman, James V.; De Cecco, Carlo Nicola; Meinel, Felix G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2014-07-15

    To evaluate the feasibility, image quality and radiation dose of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) with 30 mL contrast agent at 70 kVp. Fifty-eight patients with suspected coronary artery disease, a body mass index (BMI) of less than 25 kg/m{sup 2}, sinus rhythm and a heart rate (HR) of less than 70 beats per minute (bpm) were prospectively enrolled in this study. Thirty mL of 370 mg I/mL iodinated contrast agent was administrated at a flow rate of 5 mL/s. All patients underwent prospectively ECG-triggered high-pitch CCTA on a second-generation dual-source CT system at 70 kVp using automated tube current modulation. Fifty-six patients (96.6 %) had diagnostic CCTA images and two patients (3.4 %) had one vessel with poor image quality each rated as non-diagnostic. No significant effects of HR, HR variability and BMI on CCTA image quality were observed (all P > 0.05). Effective dose was 0.17 ± 0.02 mSv and the size-specific dose estimate was 1.03 ± 0.13 mGy. Prospectively ECG-triggered high-pitch CCTA at 70 kVp with 30 mL of contrast agent can provide diagnostic image quality at a radiation dose of less than 0.2 mSv in patients with a BMI of less than 25 kg/m{sup 2} and an HR of less than 70 bpm. (orig.)

  11. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    Science.gov (United States)

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  12. Combined 201Th myocardial scintiscanning and ECG-triggered ventricular scintiscanning for an evaluation of the left ventricular function after myocardial infarction

    International Nuclear Information System (INIS)

    Nuetzel, W.

    1978-01-01

    74 patients in whom old transmural myocardial infarctions had been detected by catheterisation of the heart were examined by 201 Th myocardial scintiscanning and ECG-triggered ventricular scintiscanning. There was a control group of 16 patients where coronary disease was excluded by the catheter examination. The findings of the nuclear methods are compared with those of invasive and non-invasive cardiological diagnostics. Nuclear techniques were more sensitive (95%) than ECG (77%) in detecting old infarctions. In volumina determination, there was a satisfactory correlation with angiography for the telediastolic volume (r = 0.77) and a good correlation for the telesystolic volume (r = 0.84) and the ejection fraction (r = 0.89). (orig./AJ) [de

  13. Noninvasive detection of regional myocardial ischemia using rubidium-81 and scintillation camera. Comparison with stress electrocardiography in patients with arteriographically documented coronary stenosis

    International Nuclear Information System (INIS)

    Berman, D.S.; Salel, A.F.; DeNardo, G.L.; Mason, D.T.

    1975-01-01

    The sensitivity of rest and stress myocardial perfusion studies using scintillation camera imaging of intravenously administered rubidium-81 ( 81 Rb) in the detection of myocardial ischemia was compared to that of stress electrocardiography by relating results in 40 patients to the degree of stenosis delineated by coronary arteriography. Of 33 patients with greater than 75 percent stenosis of at least one of the three major coronary vessels (significant stenosis), rest and stress 81 Rb imaging detected ventricular ischemia in 29 (88 percent), whereas simultaneous stress electrocardiography was positive (1 mm or greater horizontal ST-segment depression) in only 19 (58 percent) of the same patients. Five of the 29 patients who developed stress-induced scintigraphic evidence of ischemia did not develop angina or a positive electrocardiogram with stress. In 31 of the 33 patients with significant coronary stenosis, either the stress scintigram or the stress electrocardiogram was positive. In seven patients with less than 50 percent narrowing of a major coronary vessel on coronary arteriography, the stress scintigrams were negative, whereas the stress electrocardiograms were positive in the two of these patients with the syndrome of angina with normal coronary arteriograms. It is concluded that high resolution images of the myocardium can be obtained with 81 Rb using the scintillation camera with special shielding, and that rest and stress 81 Rb scintigraphy appears to provide greater sensitivity and specificity when compared to stress electrocardiography in the noninvasive identification of significant coronary stenosis

  14. Noninvasive diagnostic test choices for the evaluation of coronary artery disease in women: a multivariate comparison of cardiac fluoroscopy, exercise electrocardiography and exercise thallium myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Hung, J.; Chaitman, B.R.; Lam, J.; Lesperance, J.; Dupras, G.; Fines, P.; Bourassa, M.G.

    1984-01-01

    Several diagnostic noninvasive tests to detect coronary and multivessel coronary disease are available for women. However, all are imperfect and it is not yet clear whether one particular test provides substantially more information than others. The aim of this study was to evaluate clinical findings, exercise electrocardiography, exercise thallium myocardial scintigraphy and cardiac fluoroscopy in 92 symptomatic women without previous infarction and determine which tests were most useful in determining the presence of coronary disease and its severity. Univariate analysis revealed two clinical, eight exercise electrocardiographic, seven myocardial scintigraphic and seven fluoroscopic variables predictive of coronary or multivessel disease with 70% or greater stenosis. The multivariate discriminant function analysis selected a reversible thallium defect, coronary calcification and character of chest pain syndrome as the variables most predictive of presence or absence of coronary disease. The ranked order of variables most predictive of multivessel disease were cardiac fluoroscopy score, thallium score and extent of ST segment depression in 14 electrocardiographic leads. Each provided statistically significant information to the model. The estimate of predictive accuracy was 89% for coronary disease and 97% for multivessel coronary disease. The results suggest that cardiac fluoroscopy or thallium scintigraphy provide significantly more diagnostic information than exercise electrocardiography in women over a wide range of clinical patient subsets

  15. Application of iterative reconstruction in prospective electrocardiography-triggered CT coronary angiography

    International Nuclear Information System (INIS)

    Hou Yang; Yu Bing; Guo Qiyong; Wang Yuke; Yu Mei

    2013-01-01

    Objective: To assess the image quality (IQ) of an iterative reconstruction (IR) technique (iDose"4) from prospective electrocardiography (ECG)-triggered coronary CTA on a 256 MSCT scanner and determine the optimal dose reduction using IR that can provide IQ comparable to filtered back projection (FBP). Methods: Prospectively ECG gated CCTA were performed on 120 patients [76 men, 44 women; age: (53 ± 10) y] using a 256-slice MSCT (Brilliance iCT, Philips Healthcare). The control group (Group A , n = 30) were scanned using the conventional tube output (120 kVp, 210 mAs) and reconstructed using FBP. The other 3 groups were scanned with the same kVp but successively reduced tube output as follows: B (n = 30) : 105 mAs , C (n = 30) : 84 mAs: D (n = 30) : 65 mAs and reconstructed using IR levels of L4 to L6, respectively. All images were reconstructed using the same kernel (XCB). Two radiologists graded IQ in a blinded fashion on a 4-point scale (4-excellent, 3-good, 2-fair and 1-poor). Quantitative measurements of CT values, image noise, Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were obtained in each group. Analysis of variance (ANOVA) was used for comparisons of objective evaluation indices (noise, CNR) and radiation dose (CTDIvol, DLP, ED) between the four groups. The Kruskal-Wallis test was used for comparisons of demographic data and for detection of differences in subjective evaluation of IQ among groups. A level of P < 0.05 was considered statistically significant. A ROC analysis was performed to determine a radiation reduction threshold up to which excellent IQ was maintained. Results: There was no significant differences in objective noise among Groups A (37.4 ± 7.9) HU, B (33.2 ± 7.1) HU, C (35.7 ± 9.8) HU, and D (36.0 ± 6.8) HU (F = 1.48, P = 0.22). There was no significant differences in CNR among Groups A (15.0 ± 2.3), B (16.5 ± 3.6), C (16.3 ± 3.5), and D (15.3 ± 2.8) (F = 1.70, P = 0.17). Group B and C had good and excellent

  16. In vitro measurement of CT density and estimation of stenosis related to coronary soft plaque at 100 kV and 120 kV on ECG-triggered scan

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun, E-mail: horiguch@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Fujioka, Chikako, E-mail: fujioka@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Kiguchi, Masao, E-mail: kiguchi@hiroshima-u.ac.jp [Department of Clinical Radiology, Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Yamamoto, Hideya, E-mail: hideyayama@hiroshima-u.ac.jp [Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical Sciences and Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan); Shen, Yun, E-mail: Yuna.Shen@ge.com [CT Lab of Great China, GE Healthcare, L12 and L15, Office Tower, Langham Place, 8 Argyle Street, Mongkok Kowloon (Hong Kong); Kihara, Yasuki, E-mail: ykihara@hiroshima-u.ac.jp [Department of Cardiovascular Medicine, Hiroshima University Graduate School of Biomedical Sciences and Hiroshima University Hospital, 1-2-3, Kasumi-cho, Minami-ku, Hiroshima 734-8551 (Japan)

    2011-02-15

    Purpose: The purpose of the study was to compare 100 kV and 120 kV prospective electrocardiograph (ECG)-triggered axial coronary 64-detector CT angiography (64-MDCTA) in soft plaque diagnosis. Materials and methods: Coronary artery models (n = 5) with artificial soft plaques (-32 HU to 53 HU at 120 kV) with three stenosis levels (25%, 50% and 75%) on a cardiac phantom (mimicking slim patient's environment) were scanned in heart rates of 55, 60 and 65 beats per minute (bpm). Four kinds of intracoronary enhancement (205 HU, 241 HU, 280 HU and 314 HU) were simulated. The soft plaque density and the measurement error of stenosis (in percentage), evaluated by two independent observers, were compared between 100 kV and 120 kV. The radiation dose was estimated. Results: Interobserver correlation of the measurement was excellent (density; r = 0.95 and stenosis measure; r = 0.97). Neither the density of soft plaque nor the measurement error of stenosis was different between 100 kV and 120 kV (p = 0.22 and 0.08). The estimated radiation doses were 2.0 mSv and 3.3 mSv (in 14 cm coverage) on 100 kV and 120 kV prospective ECG-triggered axial scans, respectively. Conclusion: The 100 kV prospective ECG-triggered coronary MDCTA has comparable performance to 120 kV coronary CTA in terms of soft plaque densitometry and measurement of stenosis, with a reduced effective dose of 2 mSv.

  17. Individualized radiation dose control in 256-slice CT coronary angiography (CTCA) in retrospective ECG-triggered helical scans: Using a measure of body size to adjust tube current selection

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jing-Lei, E-mail: lijinglei80@126.com [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Huang, Mei-Ping, E-mail: huang_meiping@yahoo.com.cn [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Liang, Chang-Hong, E-mail: cjr.lchh@vip.163.com [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Zhao, Zhen-Jun, E-mail: junabc2006@hotmail.com [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Liu, Hui, E-mail: liuhuijiujiu@gmail.com [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Cui, Yan-Hai, E-mail: yanhai_cui@126.com [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Liu, Qi-Shun, E-mail: liuqishun@yeah.net [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Zhang, Jin-E., E-mail: zhjine@yahoo.com.cn [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Yang, Lin, E-mail: yanglin001517@163.com [Department of Radiology, Guangdong Academy of Medical Sciences, Guangdong General Hospital, 106 Zhongshan Er Road, Guangzhou 510080 (China); Ivanc, Thomas B., E-mail: Thomas.ivanc@philips.com [CT Clinical Science, Philips Healthcare, Highland Heights, OH (United States); Yanof, Jeffrey H., E-mail: Jeffrey.yanof@philips.com [CT Clinical Science, Philips Healthcare, Highland Heights, OH (United States)

    2012-11-15

    Purpose: To reduce radiation dose for retrospective ECG-triggered helical 256-slice CTCA by determining an optimal body size index to prospectively adjust tube current. Methods: 102 consecutive patients with suspected CAD underwent retrospective ECG-triggered CTCA using 256-slice CT scanner. Six body size indexes including BMI, nipple level (NL) bust, thoracic anteroposterior diameter at NL, chest circumference (CC) at NL, left main and right coronary artery (RCA) origin level were measured and their correlation with noise was evaluated using linear regression. An equation was developed to use this index to adjust tube current. Additional 102 consecutive patients were scanned with the index-based mA s adjustment. A t-test for independent samples was used to compare radiation dose levels with and without the index-based mA s selection method. Results: Linear regression indicated that CC RCA had the best correlation with noise (R{sup 2} = 0.603). Effective radiation dose was reduced from 16.6 {+-} 0.9 to 9.8 {+-} 2.7 mSv (p < 0.01), i.e. 40.9% lower dose with the CC RCA-adapted tube current method. The image quality scores indicated no significant difference with and without the size-based mA s selection method. Conclusion: An accessible measure of body size, such as CC RCA, can be used to adapt tube current for individualized radiation dose control.

  18. Individualized radiation dose control in 256-slice CT coronary angiography (CTCA) in retrospective ECG-triggered helical scans: Using a measure of body size to adjust tube current selection

    International Nuclear Information System (INIS)

    Li, Jing-Lei; Huang, Mei-Ping; Liang, Chang-Hong; Zhao, Zhen-Jun; Liu, Hui; Cui, Yan-Hai; Liu, Qi-Shun; Zhang, Jin-E.; Yang, Lin; Ivanc, Thomas B.; Yanof, Jeffrey H.

    2012-01-01

    Purpose: To reduce radiation dose for retrospective ECG-triggered helical 256-slice CTCA by determining an optimal body size index to prospectively adjust tube current. Methods: 102 consecutive patients with suspected CAD underwent retrospective ECG-triggered CTCA using 256-slice CT scanner. Six body size indexes including BMI, nipple level (NL) bust, thoracic anteroposterior diameter at NL, chest circumference (CC) at NL, left main and right coronary artery (RCA) origin level were measured and their correlation with noise was evaluated using linear regression. An equation was developed to use this index to adjust tube current. Additional 102 consecutive patients were scanned with the index-based mA s adjustment. A t-test for independent samples was used to compare radiation dose levels with and without the index-based mA s selection method. Results: Linear regression indicated that CC RCA had the best correlation with noise (R 2 = 0.603). Effective radiation dose was reduced from 16.6 ± 0.9 to 9.8 ± 2.7 mSv (p < 0.01), i.e. 40.9% lower dose with the CC RCA-adapted tube current method. The image quality scores indicated no significant difference with and without the size-based mA s selection method. Conclusion: An accessible measure of body size, such as CC RCA, can be used to adapt tube current for individualized radiation dose control.

  19. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J.; Xu, J.

    2010-01-01

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 ± 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  20. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J. [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Xu, J., E-mail: xujianr@hotmail.co [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China)

    2010-10-15

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 {+-} 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  1. Prospective ECG-triggered axial CT at 140-kV tube voltage improves coronary in-stent restenosis visibility at a lower radiation dose compared with conventional retrospective ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Horiguchi, Jun; Fujioka, Chikako; Kiguchi, Masao; Kohno, Shingo [Hiroshima University Hospital, Department of Clinical Radiology, Hiroshima (Japan); Yamamoto, Hideya; Kitagawa, Toshiro [Hiroshima University, Department of Molecular and Internal Medicine, Division of Clinical Medical Science, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan); Ito, Katsuhide [Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics, Programs for Applied Biomedicine, Graduate School of Biomedical Sciences, Hiroshima (Japan)

    2009-10-15

    The purpose of this study was to compare coronary 64-slice CT angiography (CTA) protocols, specifically prospective electrocardiograph (ECG)-triggered and retrospective ECG-gated CT acquisition performed using a tube voltage of 140 kV and 120 kV, regarding intracoronary stent imaging. Coronary artery stents (n=12) with artificial in-stent restenosis (50% luminal reduction, 40 HU) on a cardiac phantom were examined by CT at heart rates of 50-75 beats per minute (bpm). The subjective visibility of in-stent restenosis was evaluated with a three-point scale (1 clearly visible, 2 visible, and 3 not visible), and artificial lumen narrowing [(inner stent diameter - measured lumen diameter)/inner stent diameter], lumen attenuation increase ratio [(in-stent attenuation - coronary lumen attenuation)/coronary lumen attenuation], and signal-to-noise ratio of in-stent lumen were determined. The effective dose was estimated. The artificial lumen narrowing (mean 43%), the increase of lumen attenuation (mean 46%), and signal-to-noise ratio (mean 7.8) were not different between CT acquisitions (p=0.12-0.91). However, the visibility scores of in-stent restenosis were different (p<0.05) between ECG-gated CTA techniques: (a) 140-kV prospective (effective dose 4.6 mSv), 1.6; (b) 120-kV prospective (3.3 mSv), 1.8; (c) 140-kV retrospective (16.4-18.8 mSv), 1.9; and (d) 120-kV retrospective (11.0-13.4 mSv), 1.9. Thus, 140-kV prospective ECG-triggered CTA improves coronary in-stent restenosis visibility at a lower radiation dose compared with retrospective ECG-gated CTA. (orig.)

  2. Coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT: dual-source ECG-triggered sequential scan vs. single-source non-ECG-synchronized spiral scan

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Yang, Dong Hyun [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of)

    2010-10-15

    The potential impact of dual-source ECG-triggered sequential CT scan on coronary artery visibility has not been evaluated in free-breathing young children. To compare coronary artery visibility in free-breathing young children with congenital heart disease on cardiac 64-slice CT between dual-source ECG-triggered sequential (DSET) scan and single-source non-ECG-synchronized spiral (SSNE) scan. In 93 young children, 108 cardiac 64-slice CT examinations were performed during free-breathing. Visibility of coronary arteries and side branches was compared between SSNE and DSET scans. Heart rates and trigger delays for DSET scan were recorded. Effective dose of each scan technique was calculated. Visual grades were significantly higher (P < 0.001 or =0.011) on DSET scan than on SSNE scan except for the distal left anterior descending artery. Coronary arteries were traceable in 79.3% on DSET scan and 54.3% on SSNE scan in the overlapped scan range (P < 0.0001), and 97.1% and 71.9% for the origins and proximal segments (P < 0.0001). Visibility of side branches was improved on DSET scan by a factor of 2.0. Heart rates and trigger delays for DSET scan were 131 {+-} 24 beats per min and 199 {+-} 44 ms, respectively. Effective doses of DSET and SSNE scans were 0.36 {+-} 0.12 mSv and 0.99 {+-} 0.23 mSv, respectively. DSET scan improves visibility of coronary arteries on cardiac 64-slice CT in free-breathing young children with congenital heart disease, compared with SSNE scan. (orig.)

  3. Implementation of integrated heterogeneous electronic electrocardiography data into Maharaj Nakorn Chiang Mai Hospital Information System.

    Science.gov (United States)

    Khumrin, Piyapong; Chumpoo, Pitupoom

    2016-03-01

    Electrocardiography is one of the most important non-invasive diagnostic tools for diagnosing coronary heart disease. The electrocardiography information system in Maharaj Nakorn Chiang Mai Hospital required a massive manual labor effort. In this article, we propose an approach toward the integration of heterogeneous electrocardiography data and the implementation of an integrated electrocardiography information system into the existing Hospital Information System. The system integrates different electrocardiography formats into a consistent electrocardiography rendering by using Java software. The interface acts as middleware to seamlessly integrate different electrocardiography formats. Instead of using a common electrocardiography protocol, we applied a central format based on Java classes for mapping different electrocardiography formats which contains a specific parser for each electrocardiography format to acquire the same information. Our observations showed that the new system improved the effectiveness of data management, work flow, and data quality; increased the availability of information; and finally improved quality of care. © The Author(s) 2014.

  4. Eyewitness to history: Landmarks in the development of computerized electrocardiography.

    Science.gov (United States)

    Rautaharju, Pentti M

    2016-01-01

    The use of digital computers for ECG processing was pioneered in the early 1960s by two immigrants to the US, Hubert Pipberger, who initiated a collaborative VA project to collect an ECG-independent Frank lead data base, and Cesar Caceres at NIH who selected for his ECAN program standard 12-lead ECGs processed as single leads. Ray Bonner in the early 1970s placed his IBM 5880 program in a cart to print ECGs with interpretation, and computer-ECG programs were developed by Telemed, Marquette, HP-Philips and Mortara. The "Common Standards for quantitative Electrocardiography (CSE)" directed by Jos Willems evaluated nine ECG programs and eight cardiologists in clinically-defined categories. The total accuracy by a representative "average" cardiologist (75.5%) was 5.8% higher than that of the average program (69.7, p<0.001). Future comparisons of computer-based and expert reader performance are likely to show evolving results with continuing improvement of computer-ECG algorithms and changing expertise of ECG interpreters. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Development and clinical study of mobile 12-lead electrocardiography based on cloud computing for cardiac emergency.

    Science.gov (United States)

    Fujita, Hideo; Uchimura, Yuji; Waki, Kayo; Omae, Koji; Takeuchi, Ichiro; Ohe, Kazuhiko

    2013-01-01

    To improve emergency services for accurate diagnosis of cardiac emergency, we developed a low-cost new mobile electrocardiography system "Cloud Cardiology®" based upon cloud computing for prehospital diagnosis. This comprises a compact 12-lead ECG unit equipped with Bluetooth and Android Smartphone with an application for transmission. Cloud server enables us to share ECG simultaneously inside and outside the hospital. We evaluated the clinical effectiveness by conducting a clinical trial with historical comparison to evaluate this system in a rapid response car in the real emergency service settings. We found that this system has an ability to shorten the onset to balloon time of patients with acute myocardial infarction, resulting in better clinical outcome. Here we propose that cloud-computing based simultaneous data sharing could be powerful solution for emergency service for cardiology, along with its significant clinical outcome.

  6. Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

    Directory of Open Access Journals (Sweden)

    Janusz Jezewski

    2017-05-01

    Full Text Available Great expectations are connected with application of indirect fetal electrocardiography (FECG, especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US. Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D, long-term variability (LTV, as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV. The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41 and abnormal (19 fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8% and particularly deceleration (54% patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not

  7. Cleanliness of disposable vs nondisposable electrocardiography lead wires in children.

    Science.gov (United States)

    Addison, Nancy; Quatrara, Beth; Letzkus, Lisa; Strider, David; Rovnyak, Virginia; Syptak, Virginia; Fuzy, Lisa

    2014-09-01

    Mediastinitis costs hospitals thousands of dollars a year and increases the incidence of patient morbidity and mortality. No studies have been done to evaluate adenosine triphosphate (ATP) counts on disposable and nondisposable electrocardiography (ECG) lead wires in pediatric patients. To compare the cleanliness of disposable and nondisposable ECG lead wires in postoperative pediatric cardiac surgery patients by measuring the quantity of ATP (in relative luminescence units [RLUs]). ATP levels correlate with microbial cell counts and are used by institutions to assess hospital equipment and cleanliness. A prospective, randomized trial was initiated with approval from the institutional review board. Verbal consent was obtained from the parents/guardians for each patient. Trained nurses performed ATP swabs on the right and left upper ECG cables on postoperative days 1, 2, and 3. This study enrolled 51 patients. The disposable ECG lead wire ATP count on postoperative day 1 (median, 157 RLUs) was significantly lower (P disposable ECG lead wires (median, 200 RLUs) was also lower (P = .06) than the count for the nondisposable ECG lead wires (median, 453 RLUs). Results of this study support the use of disposable ECG lead wires in postoperative pediatric cardiac surgery patients for at least the first 48 hours as a direct strategy to reduce the ATP counts on ECG lead wires. ©2014 American Association of Critical-Care Nurses.

  8. An optimized lead system for long-term esophageal electrocardiography

    International Nuclear Information System (INIS)

    Niederhauser, T; Haeberlin, A; Vogel, R; Marisa, T; Goette, J; Jacomet, M; Mattle, D; Abächerli, R

    2014-01-01

    Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ECG might overcome these limitations but requires a dedicated lead system and recorder design. To this end, we analysed multiple-lead esophageal ECGs with respect to signal quality by describing the ECG waves as a function of the insertion level, interelectrode distance, electrode shape and amplifier's input range. The results derived from clinical data show that two bipolar esophageal leads, an atrial lead with short (15 mm) interelectrode distance and a ventricular lead with long (80 mm) interelectrode distance provide non-inferior ventricular signal strength and superior atrial signal strength compared to standard surface lead II. High atrial signal slope in particular is observed with the atrial esophageal lead. The proposed esophageal lead system in combination with an increased recorder input range of ±20 mV minimizes signal loss due to excessive electrode motion typically observed in esophageal ECGs. The design proposal might help to standardize long-term esophageal ECG registrations and facilitate novel ECG classification systems based on the independent detection of ventricular and atrial electrical activity. (paper)

  9. A brief review: history to understand fundamentals of electrocardiography

    Directory of Open Access Journals (Sweden)

    Joseph Lindsay

    2012-04-01

    Full Text Available The last decade of the 19th century witnessed the rise of a new era in which physicians used technology along with classical history taking and physical examination for the diagnosis of heart disease. The introduction of chest x-rays and the electrocardiograph (electrocardiogram provided objective information about the structure and function of the heart. In the first half of the 20th century, a number of innovative individuals set in motion a fascinating sequence of discoveries and inventions that led to the 12-lead electrocardiogram, as we know it now. Electrocardiography, nowadays, is an essential part of the initial evaluation for patients presenting with cardiac complaints. As a first line diagnostic tool, health care providers at different levels of training and expertise frequently find it imperative to interpret electrocardiograms. It is likely that an understanding of the electrical basis of electrocardiograms would reduce the likelihood of error. An understanding of the disorders behind electrocardiographic phenomena could reduce the need for memorizing what may seem to be an endless list of patterns. In this article, we will review the important steps in the evolution of electrocardiogram. As is the case in most human endeavors, an understanding of history enables one to deal effectively with the present.

  10. Electrocardiography may be a useful tool in the diagnosis of early mild canine heartworm disease

    Directory of Open Access Journals (Sweden)

    Edward M. Onyango

    2011-01-01

    Full Text Available This study was carried out to determine the usefulness of standard electrocardiography for the diagnosis of early canine heartworm disease. Baseline electrocardiograms were recorded in 12 dogs. Thirty artificial Dirofilaria immitis worms were inserted in the pulmonary artery of each dog. New electrocardiograms were recorded on days 1-4, 7, 14, 21, 28 and 35 after insertion of worms. A significant attenuation of amplitude of Q wave in lead I was recorded on days 1-4, 7, 14, 21, 28 and 35; of R wave in lead II on days 21, 28 and 35; and of S wave in lead aVR on days 7, 14, 21, 28 and 35. Duration of the QRS complex in lead AVF was significantly prolonged on day 14. In 41.6% of the dogs, right axis deviation was recorded. These results suggest that for a dog whose normal baseline standard electrocardiogram is known, a comparison of the QRS complex of the baseline with those of subsequent standard electrocardiograms may suggest early canine heartworm disease when there is an attenuation of amplitude of Q wave in lead I, R wave in lead II and S wave in lead aVR. An additional indication can be right axis deviation.

  11. A Comparison between Gadofosveset Trisodium and Gadobenate Dimeglumine for Steady State MRA of the Thoracic Vasculature

    OpenAIRE

    Camren, G. Paul; Wilson, Gregory J.; Bamra, Vikram R.; Nguyen, Khahn Q.; Hippe, Daniel S.; Maki, Jeffrey H.

    2014-01-01

    Purpose. Retrospective comparison between gadofosveset trisodium and gadobenate dimeglumine steady state magnetic resonance angiography (SS-MRA) of the thoracic vasculature at 1.5T using signal-to-noise ratio (SNR) and vessel edge sharpness (ES) as markers of image quality. Materials and Methods. IRB approval was obtained. Twenty separate patients each underwent SS-MRA using high-resolution 3D ECG-triggered coronal IR-TFE at 1.5T approximately 3-4 minutes following 10 or 15 mL gadofosveset or...

  12. A Trimodal System for the Acquisition of Synchronous Echocardiography, Electrocardiography, and Seismocardiography Data

    Science.gov (United States)

    Wick, Carson A.; Su, Jin-Jyh; Brand, Oliver; McClellan, James H.; Bhatti, Pamela T.; Tridandapani, Srini

    2013-01-01

    A novel system was developed to acquire synchronous echocardiography, electrocardiography (EKG), and seismocardiography (SCG) data. The system was developed to facilitate the study of the relationship between the mechanical and electrical characteristics of the heart. The system has both a hardware and software component. The hardware component consists of an application-specific device designed and built to acquire both SCG and EKG signals simultaneously. The software component consists of a package developed to record and synchronize data from both the device and a clinical ultrasound machine. A feasibility test was performed by simultaneous acquisition of a synchronous dataset from a human subject. PMID:22255927

  13. Paediatrics Electrocardiography

    African Journals Online (AJOL)

    Prof Ezechukwu

    2011-11-28

    Nov 28, 2011 ... Right axis deviation- Tetralogy of Fallot, pulmonary atresia, transposition of the great arteries (TGA). Superior axis deviation- Atrioventricular septal defect, tricuspid atresia. QRS Complex. The QRS complex represents ventricular depolarization and the normal duration 0.10 seconds or less. It is meas-.

  14. Afebrile seizures and electrocardiography abnormality: an unusual presentation of nutritional rickets.

    Science.gov (United States)

    Gad, Kg; Khan, Ma; Mahmood, K

    2014-08-01

    Nutritional rickets is not uncommon in the western world and has been reported widely. Occasionally, children have presented to paediatrics with afebrile seizures secondary to hypocalcaemia due to hypovitaminosis D. However, association of nutritional rickets with electrocardiography changes and prolonged QT interval is not well documented. It is a rare, potentially serious and yet easy-to-treat complication as shown in our case. Our case also highlights the importance of awareness and education of both parents and clinicians regarding this relatively common but easily treatable condition. We report a case of undiagnosed nutritional rickets presenting as 'Afebrile' seizure in a seven-month-old Somali girl. Her initial blood work-up showed low ionised calcium (0.8 mmol/l) on blood gas sampling, confirmed by laboratory result (adjusted 1.49 mmol/l). She had prolonged QTc on electrocardiography which reverted to normal with treatment. She was treated with intravenous as well as oral calcium after which she had no further seizures. We present a unique case of nutritional rickets-associated hypocalcaemia. This case highlights the resurgence of nutritional rickets in western societies. We need to keep this disease in our list of diagnoses as it is a potentially serious and yet easily treatable disease. We should be more vigilant for screening ethnic minorities as alarmingly high rates of hypovitaminosis D have been found in ethnic minorities living in Great Britain. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  15. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    Science.gov (United States)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  16. Is community-based electrocardiography education feasible in the early phase of an undergraduate medical curriculum?

    Directory of Open Access Journals (Sweden)

    Carol O. Larson

    2017-10-01

    Full Text Available Accreditation authorities expect medical schools to increase their teaching standards and civic engagement, despite limited resources. The aim of this study was to investigate the feasibility of community-based (CB electrocardiography (ECG instruction in semesters 4and/or 5 of the undergraduate MBChB programme at the University of the Free State in Bloemfontein, South Africa. A literature review and 34 structured interviews were employed, using a mixed-methods QUAN (þqual research design. Regarding the preclinical phase, 18 interviewees strongly supported community-based learning (CBL and 21strongly supported task-based (TB CBL. Responses were more conservative regarding the practicability of TB CBL. Twenty-two interviewees supported preclinical phase ECG-specific CBL. There was more support for implementing CB ECG in the clinical phase than in the preclinical phase. Challenges identified included finances, transport, personnel availability, clinic space, curriculum time constraints, student and driver absenteeism, and ethical aspects. Solutions for the preclinical phase included combining electrocardiography with other CBL tasks. Many interviewees supported preclinical phase TB CBL, although several factors determine its feasibility. Availability of human and other resources and curriculum time significantly impact CB ECG learning. Solutions necessitate additional location-specific research.

  17. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

    Science.gov (United States)

    Kollias, Anastasios; Destounis, Antonios; Kalogeropoulos, Petros; Kyriakoulis, Konstantinos G; Ntineri, Angeliki; Stergiou, George S

    2018-07-01

    This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats ( r =0.67; P ABP monitoring had 100%/85% sensitivity/specificity (area under the curve 0.91; P ABP monitor with AF detector has high sensitivity and moderate specificity for AF screening during routine ABP monitoring. Thus, in elderly hypertensives, a 24-hour ABP recording with at least 26% of the readings suggesting AF indicates a high probability for AF diagnosis and should be regarded as an indication for performing 24-hour Holter monitoring. © 2018 American Heart Association, Inc.

  18. Electrocardiography as an early cardiac screening test in children with mitochondrial disease

    Directory of Open Access Journals (Sweden)

    Ran Baik

    2010-05-01

    Full Text Available Purpose : To evaluate myocardial conductivity to understand cardiac involvement in patients with mitochondrial disease. Methods : We performed retrospective study on fifty-seven nonspecific mitochondrial encephalopathy patients with no clinical cardiac manifestations. The patients were diagnosed with mitochondrial respiratory chain complex defects through biochemical enzyme assays of muscle tissue. We performed standard 12-lead electrocardiography (ECG on all patients. Results : ECG abnormalities were observed in 30 patients (52.6%. Prolongation of the QTc interval (&gt;440 ms was seen in 19 patients (33.3%, widening of the corrected QRS interval in 15 (26.3%, and bundle branch block in four (7.0%. Atrioventricular block, premature atrial contraction and premature ventricular contraction were seen in two patients each (3.5% and Wolff-Parkinson-White syndrome in one patient (1.8%. Conclusion : Given this finding, we recommend active screening with ECG in patients with mitochondrial disease even in patients without obvious cardiac manifestation.

  19. Single-Wall Carbon Nanotube-Coated Cotton Yarn for Electrocardiography Transmission

    Directory of Open Access Journals (Sweden)

    Yuliang Zhao

    2018-03-01

    Full Text Available We fabricated a type of conductive fabric, specifically single-wall carbon nanotube-coated cotton yarns (SWNT-CYs, for electrocardiography (ECG signal transmission utilizing a “dipping and drying” method. The conductive cotton yarns were prepared by dipping cotton yarns in SWNTs (single-wall carbon nanotubes solutions and then drying them at room temperature—a simple process that shows consistency in successfully coating cotton yarns with conductive carbon nanotubes (CNTs. The influence of fabrication conditions on the conductivity properties of SWNT-CYs was investigated. The results demonstrate that our conductive yarns can transmit weak bio-electrical (i.e., ECG signals without significant attenuation and distortion. Our conductive cotton yarns, which combine the flexibility of conventional fabrics and the good conductivity of SWNTs, are promising materials for wearable electronics and sensor applications in the future.

  20. Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries.

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    Full Text Available PURPOSE: To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol, compared with single coronary CTA. MATERIALS AND METHODS: 151 consecutive patients were prospectively included and randomly divided into three groups. Group 1 (n = 47 underwent combined heart, neck, and head CTA using prospectively ECG-triggered high-pitch spiral (Flash scan protocol with a single-phase intravenous injection of iodinated contrast and saline flush; Group 2 (n = 51 underwent single coronary CTA with Flash scan protocol; and Group 3 (n = 53 underwent single coronary CTA with prospective sequence scan protocol. All patients were examined on a dual source CT (Definition FLASH. The image quality was determined for each CT study. RESULTS: Patients of scanning protocol Group 1, 2, and 3 showed no significant differences in age, sex, heart rates, and BMI. Evaluation of coronary artery image quality showed comparable results in the three scanning protocol groups on a per patient-based analysis. In group 1, image quality was found to be sufficient to be diagnostic in all arterial segments of carotid arteries. The mean dose-length product (DLP for group 1 was 256.3±24.5 mGy×cm and was significantly higher in comparison with group 2 (93.4±19.9 mGy×cm; p < 0.001. However, there was no significant difference of DLP between group 1 and group 3 (254.1±69.9 mGy×cm. CONCLUSIONS: The combined heart, neck, and head arteries scan using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol in 1 single examination resulted in an excellent opacification of the aorta, the carotid arteries, and the coronary arteries and provided a good image quality with low radiation dose.

  1. The use of non-invasive fetal electrocardiography in diagnosing second-degree fetal atrioventricular block.

    Science.gov (United States)

    Lakhno, Igor; Behar, Joachim A; Oster, Julien; Shulgin, Vyacheslav; Ostras, Oleksii; Andreotti, Fernando

    2017-01-01

    Complete atrioventricular block in fetuses is known to be mostly associated with autoimmune disease and can be irreversible if no steroids treatment is provided. Conventional methods used in clinical practice for diagnosing fetal arrhythmia are limited since they do not reflect the primary electrophysiological conduction processes that take place in the myocardium. The non-invasive fetal electrocardiogram has the potential to better support fetal arrhythmias diagnosis through the continuous analysis of the beat to beat variation of the fetal heart rate and morphological analysis of the PQRST complex. We present two retrospective case reports on which atrioventricular block diagnosis could have been supported by the non-invasive fetal electrocardiogram. The two cases comprised a 22-year-old pregnant woman with the gestational age of 31 weeks and a 25-year-old pregnant woman with the gestational age of 41 weeks. Both women were admitted to the Department of Maternal and Fetal Medicine at the Kyiv and Kharkiv municipal perinatal clinics. Patients were observed using standard fetal monitoring methods as well as the non-invasive fetal electrocardiogram. The non-invasive fetal electrocardiographic recordings were analyzed retrospectively, where it is possible to identify the presence of the atrioventricular block. This study demonstrates, for the first time, the feasibility of the non-invasive fetal electrocardiogram as a supplementary method to diagnose of the fetal atrioventricular block. Combined with current fetal monitoring techniques, non-invasive fetal electrocardiography could support clinical decisions.

  2. Interoperability in digital electrocardiography: harmonization of ISO/IEEE x73-PHD and SCP-ECG.

    Science.gov (United States)

    Trigo, Jesús D; Chiarugi, Franco; Alesanco, Alvaro; Martínez-Espronceda, Miguel; Serrano, Luis; Chronaki, Catherine E; Escayola, Javier; Martínez, Ignacio; García, José

    2010-11-01

    The ISO/IEEE 11073 (x73) family of standards is a reference frame for medical device interoperability. A draft for an ECG device specialization (ISO/IEEE 11073-10406-d02) has already been presented to the Personal Health Device (PHD) Working Group, and the Standard Communications Protocol for Computer-Assisted ElectroCardioGraphy (SCP-ECG) Standard for short-term diagnostic ECGs (EN1064:2005+A1:2007) has recently been approved as part of the x73 family (ISO 11073-91064:2009). These factors suggest the coordinated use of these two standards in foreseeable telecardiology environments, and hence the need to harmonize them. Such harmonization is the subject of this paper. Thus, a mapping of the mandatory attributes defined in the second draft of the ISO/IEEE 11073-10406-d02 and the minimum SCP-ECG fields is presented, and various other capabilities of the SCP-ECG Standard (such as the messaging part) are also analyzed from an x73-PHD point of view. As a result, this paper addresses and analyzes the implications of some inconsistencies in the coordinated use of these two standards. Finally, a proof-of-concept implementation of the draft x73-PHD ECG device specialization is presented, along with the conversion from x73-PHD to SCP-ECG. This paper, therefore, provides recommendations for future implementations of telecardiology systems that are compliant with both x73-PHD and SCP-ECG.

  3. Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors.

    Science.gov (United States)

    Ozawa, Yoshiyuki; Hara, Masaki; Nakagawa, Motoo; Shibamoto, Yuta

    2016-01-01

    Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. Forty thymic epithelial tumors (36 thymomas and 4 thymic carcinomas) were examined with ECG-gated contrast-enhanced CT using a dual source scanner. The scan delay after the contrast media injection was 30 s for the non-ECG-gated CT and 100 s for the ECG-gated CT. Two radiologists blindly evaluated both the non-ECG-gated and ECG-gated CT images for motion artifacts and determined whether the tumors had invaded adjacent structures (mediastinal fat, superior vena cava, brachiocephalic veins, aorta, pulmonary artery, pericardium, or lungs) on each image. Motion artifacts were evaluated using a 3-grade scale. Surgical and pathological findings were used as a reference standard for tumor invasion. Motion artifacts were significantly reduced for all structures by ECG gating ( p =0.0089 for the lungs and p ECG-gated CT and ECG-gated CT demonstrated 79% and 95% accuracy, respectively, during assessments of pericardial invasion ( p =0.03). ECG-gated CT reduced the severity of motion artifacts and might be useful for preoperative assessment whether thymic epithelial tumors have invaded adjacent structures.

  4. A novel method of fabricating carbon nanotubes-polydimethylsiloxane composite electrodes for electrocardiography.

    Science.gov (United States)

    Liu, Benyan; Chen, Yingmin; Luo, Zhangyuan; Zhang, Wenzan; Tu, Quan; Jin, Xun

    2015-01-01

    Polymer-based flexible electrodes are receiving much attention in medical applications due to their good wearing comfort. The current fabrication methods of such electrodes are not widely applied. In this study, polydimethylsiloxane (PDMS) and conductive additives of carbon nanotubes (CNTs) were employed to fabricate composite electrodes for electrocardiography (ECG). A three-step dispersion process consisting of ultrasonication, stirring, and in situ polymerization was developed to yield homogenous CNTs-PDMS mixtures. The CNTs-PDMS mixtures were used to fabricate CNTs-PDMS composite electrodes by replica technology. The influence of ultrasonication time and CNT concentration on polymer electrode performance was evaluated by impedance and ECG measurements. The signal amplitude of the electrodes prepared using an ultrasonication time of 12 h and CNT content of 5 wt% was comparable to that of commercial Ag/AgCl electrodes. The polymer electrodes were easily fabricated by conventional manufacturing techniques, indicating a potential advantage of reduced cost for mass production.

  5. Exercise thallium-201 scintigraphy and prognosis in typical angina pectoris and negative exercise electrocardiography

    International Nuclear Information System (INIS)

    Bairey, C.N.; Rozanski, A.; Maddahi, J.; Resser, K.J.; Berman, D.S.

    1989-01-01

    Patients with a history of typical angina but negative exercise electrocardiography represent a subgroup with an intermediate likelihood of having coronary artery disease and future cardiac events. A retrospective study of the prognostic utility of stress-redistribution thallium-201 scintigraphy was performed in 190 such patients. A second group of 203 patients with typical angina and a positive exercise electrocardiogram were analyzed for comparative scintigraphic purposes. The cardiac event rate for the 144 negative exercise electrocardiogram patients with normal thallium results was 5 vs 15% in the 46 patients with abnormal thallium results (p = 0.01). These patients were further stratified into high (14 to 18%), intermediate (9%) and low (less than 2%) risk groups for future cardiac events based on combining the thallium results with the percentage of maximal predicted heart rate achieved. A multivariate analysis revealed that an abnormal thallium result was the only significant correlate of future cardiac events. Mechanisms responsible for the discordant finding of a negative exercise electrocardiogram in patients with typical angina include (1) false-positive angina symptomatology in low prevalence coronary artery disease groups in whom the thallium test is negative, and (2) electrocardiographically silent ischemia in patients in whom the thallium test is positive. These findings reveal that thallium stress-redistribution scintigraphy can be used to stratify 1-year prognosis in this subgroup of patients with typical angina and negative exercise electrocardiograms

  6. Effects of negative T wave in electrocardiography on prognosis of post-myocardial infarction patients

    Directory of Open Access Journals (Sweden)

    Reza Karbasi-Afshar

    2013-03-01

    Full Text Available BACKGROUND: Negative T (NT wave in electrocardiography (ECG is one of the important factors in determining short- and long-term outcomes in patients with acute myocardial infarction (MI. In this study, we compared clinical and paraclinical findings in post-MI patients according to presence or absence of NT wave. METHODS: A cross-sectional study was conducted on patients with acute ST elevation MI who presented to Shahid Modares Hospital (Tehran, Iran during 2009-10. After undergoing streptokinase therapy, demographic characteristics and ECG and exercise test findings of the subjects were compared based on the presence or absence of NT wave. RESULTS: Overall, 116 patients including 69 cases with NT wave (NT group and 47 cases without NT wave (PT group were enrolled (mean age: 53.7 ± 7.1 vs. 54.1 ± 6.8 years old. Mortality rate during the first five days was 13% in the NT group and 29% in the PT group (P < 0.05. Ejection fraction values of the NT group were significantly higher than the PT group (P = 0.005. However, left ventricular end-diastolic diameter of the NT group was significantly less than the PT group (P = 0.005. Moreover, ST segment depression was significantly less frequent in the NT group compared to the PT group. CONCLUSION: Patients with ST elevation MI accompanying with NT wave in ECG versus have better prognosis and myocardial function than similar patients without NT wave. Therefore, invasive procedures should be recommended for patients without NT wave.   Keywords: Echocardiography, Exercise Test, Myocardial Infarction, Negative T Wave, Echocardiography

  7. Localization of coronary artery disease with exercise electrocardiography: correlation with thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.F.; Freedman, B.; Bailey, I.K.; Uren, R.F.; Kelly, D.T.

    1981-01-01

    In 61 patients with single vessel coronary artery disease (70 percent or greater obstruction of luminal diameter in only one vessel) and no previous myocardial infarction, the sites of ischemic changes on 12 lead exercise electrocardiography and on thallium-201 myocardial perfusion scanning were related to the obstructed coronary artery. The site of exercise-induced S-T segment depression did not identify which coronary artery was obstructed. In the 37 patients with left anterior descending coronary artery disease S-T depression was most often seen in the inferior leads and leads V4 to V6, and in the 18 patients with right coronary artery disease and in the 6 patients with left circumflex artery disease S-T depression was most often seen in leads V5 and V6. Although S-T segment elevation was uncommon in most leads, it occurred in lead V1 or a VL, or both, in 51 percent of the patients with left anterior descending coronary artery disease. A reversible anterior defect on exercise thallium scanning correlated with left anterior descending coronary artery disease (probability [p] less than 0.0001) and a reversible inferior thallium defect correlated with right coronary or left circumflex artery disease (p less than 0.0001). In patients with single vessel disease, the site of S-T segment depression does not identify the obstructed coronary artery; S-T segment elevation in lead V1 or aVL, or both, identifies left anterior descending coronary artery disease; and the site of reversible perfusion defect on thallium scanning identifies the site of myocardial ischemia and the obstructed coronary artery

  8. Malignant arrhythmia as the first manifestation of Wolff-Parkinson-White syndrome: a case with minimal preexcitation on electrocardiography.

    Science.gov (United States)

    Gungor, B; Alper, A T

    2013-09-01

    Wolff-Parkinson-White (WPW) syndrome is defined as the presence of an accessory atrioventricular pathway which is manifested as delta waves and short PR interval on electrocardiography (ECG). However, some WPW cases do not have typical findings on ECG and may remain undiagnosed unless palpitations occur. Sudden cardiac death may be the first manifestation of WPW and develops mostly secondary to degeneration of atrial fibrillation into ventricular fibrillation. In this report, we present a case of undiagnosed WPW with minimal preexcitation on ECG and who suffered an episode of malignant arrhythmia as the first manifestation of the disease.

  9. Exercise electrocardiography and myocardial scintigraphy in the serial evaluation of the results of percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Schall, J.M.; Chaitman, B.R.; David, P.R.; Dupras, G.; Brevers, G; Val, P.G.; Crepeau, J.; Lesperance, J.; Bourassa, M.G.

    1982-01-01

    The diagnostic value of exercise electrocardiography using 14 leads and thallium-201 scintigraphy were evaluated in 54 of 70 patients who underwent percutaneous transluminal coronary angioplasty (PTCA), both in the initial assessment and serial follow-up of patients after PTCA. Of the 45 patients who had successful PTCA, 36 had complete noninvasive studies performed before and 1 month after PTCA. The use of clinical symptoms in conjunction with the physiologic data, ECG and myocardial scintigram acquired during exercise provide important short-term data on the angiographic evolution of PTCA results. The noninvasive tests may be useful in determining guidelines for repeat angiography in patients who have had PTCA

  10. Inter-Rater Reliability and Downstream Financial Implications of Electrocardiography Screening in Young Athletes.

    Science.gov (United States)

    Dhutia, Harshil; Malhotra, Aneil; Yeo, Tee Joo; Ster, Irina Chis; Gabus, Vincent; Steriotis, Alexandros; Dores, Helder; Mellor, Greg; García-Corrales, Carmen; Ensam, Bode; Jayalapan, Viknesh; Ezzat, Vivienne Anne; Finocchiaro, Gherardo; Gati, Sabiha; Papadakis, Michael; Tome-Esteban, Maria; Sharma, Sanjay

    2017-08-01

    Preparticipation screening for cardiovascular disease in young athletes with electrocardiography is endorsed by the European Society of Cardiology and several major sporting organizations. One of the concerns of the ECG as a screening test in young athletes relates to the potential for variation in interpretation. We investigated the degree of variation in ECG interpretation in athletes and its financial impact among cardiologists of differing experience. Eight cardiologists (4 with experience in screening athletes) each reported 400 ECGs of consecutively screened young athletes according to the 2010 European Society of Cardiology recommendations, Seattle criteria, and refined criteria. Cohen κ coefficient was used to calculate interobserver reliability. Cardiologists proposed secondary investigations after ECG interpretation, the costs of which were based on the UK National Health Service tariffs. Inexperienced cardiologists were more likely to classify an ECG as abnormal compared with experienced cardiologists (odds ratio, 1.44; 95% confidence interval, 1.03-2.02). Modification of ECG interpretation criteria improved interobserver reliability for categorizing an ECG as abnormal from poor (2010 European Society of Cardiology recommendations; κ=0.15) to moderate (refined criteria; κ=0.41) among inexperienced cardiologists; however, interobserver reliability was moderate for all 3 criteria among experienced cardiologists (κ=0.40-0.53). Inexperienced cardiologists were more likely to refer athletes for further evaluation compared with experienced cardiologists (odds ratio, 4.74; 95% confidence interval, 3.50-6.43) with poorer interobserver reliability (κ=0.22 versus κ=0.47). Interobserver reliability for secondary investigations after ECG interpretation ranged from poor to fair among inexperienced cardiologists (κ=0.15-0.30) and fair to moderate among experienced cardiologists (κ=0.21-0.46). The cost of cardiovascular evaluation per athlete was $175 (95

  11. The clinical value and limitation of exercise electrocardiography and exercise thallium-201 myocardial scintigraphy in the diagnosis of coronary artery disease, with special reference to single vessel disease

    International Nuclear Information System (INIS)

    Fujioka, Tatsuo; Shibata, Nitaro; Shimizu, Yoichi; Itoh, Yukiyoshi; Abe, Mitsuki; Tanaka, Toshihide; Matsuda, Mitsukazu; Obunai, Yoshio

    1984-01-01

    The clinical value and limitation of exercise electrocardiography and exercise thallium-201 myocardial scintigraphy were studied in 40 patients with no previous history of myocardial infarction. Coronary angiography was performed on all the patients. Compared with thallium-201 myocardial scintigraphy, treadmill exercise electrocardiography showed greater sensitivity (84% versus 63%) in diagnosing coronary stenosis of more than 50%. In patients with single vessel discase, the results of sensitivities were similar (75% to 65%). However, the specificity of thallium-201 myocardial scintigraphy was higher than that of exercise electrocardiography (100% compared to 63%). Nine patients with evidence of significant lesions using coronary angiography, showed normal conditions using exercise electrocardiography and thallium myocardial scintigraphy examinations as well. All these patients had a history of chest pain, and 4 of them experienced chest pain during exercise. In cases with false negative exercise tests, the clinical symptoms and exercise-induced chest pain seem to be important diagnostic signs when evaluating patients with coronary artery disease. In 15 patients with isolated single vessel coronary artery disease (more than 75% stenosis of luminal diameter in only one vessel), the site of ST segment depression did not coincide with the stenotic lesion. The site of reversible perfusion defect on thallium-201 myocardial scintigraphy did, however, coincide with the site of myocardial ishemia and the stenotic lesion in most cases. (author)

  12. FPGA-based electrocardiography (ECG signal analysis system using least-square linear phase finite impulse response (FIR filter

    Directory of Open Access Journals (Sweden)

    Mohamed G. Egila

    2016-12-01

    Full Text Available This paper presents a proposed design for analyzing electrocardiography (ECG signals. This methodology employs highpass least-square linear phase Finite Impulse Response (FIR filtering technique to filter out the baseline wander noise embedded in the input ECG signal to the system. Discrete Wavelet Transform (DWT was utilized as a feature extraction methodology to extract the reduced feature set from the input ECG signal. The design uses back propagation neural network classifier to classify the input ECG signal. The system is implemented on Xilinx 3AN-XC3S700AN Field Programming Gate Array (FPGA board. A system simulation has been done. The design is compared with some other designs achieving total accuracy of 97.8%, and achieving reduction in utilizing resources on FPGA implementation.

  13. Comparison of electrocardiography and thallium-201 myocardial scintigraphy for the detection of ergonovine-induced coronary artery spasm: angiographic correlation

    International Nuclear Information System (INIS)

    Shanes, J.G.; Pavel, D.; Blend, M.

    1987-01-01

    This study was performed to determine the sensitivity of thallium imaging vs ECG monitoring for detecting coronary artery spasm noninvasively following intravenous ergonovine administration as compared to simultaneous coronary angiography. Thirty-two patients with insignificant coronary artery disease and chest pain underwent 12-lead ECG monitoring, thallium imaging, and coronary arteriography following the administration of 0.05, 0.1, 0.2, and 0.3 mg of ergonovine given 5 minutes apart or until chest pain occurred. One minute following the last dose of ergonovine, 2.5 mCi of thallium-201 was injected intravenously, and a final ECG was recorded and repeat coronary arteriography performed. Within 10 minutes following the injection of thallium, imaging was performed in the 40-degree and 70-degree left anterior oblique and anterior projections. The ECG, thallium study, and coronary arteriogram were read blindly and results were compared. The ECG, angiogram, and thallium study were read as positive if the following occurred, respectively: greater than or equal to 1 mm ST segment elevation, depression, or T wave reversal; greater than 50% vessel narrowing,; and reversible perfusion defect. Five patients were excluded from analysis because of either catheter-induced spasm, suboptimal thallium studies, or protocol violations. Of the 27 patients included for analysis, six had chest pain, five had a positive angiogram, five had a positive thallium study, and one had a positive ECG. The sensitivity of thallium vs ECG monitoring was 80% vs 25%, and the accuracy was 92% vs 80%. We conclude that thallium imaging greatly increases the noninvasive detection of ergonovine-induced coronary spasm as compared with the ECG with no loss of accuracy

  14. A Unique Digital Electrocardiographic Repository for the Development of Quantitative Electrocardiography and Cardiac Safety: The Telemetric and Holter ECG Warehouse (THEW)

    Science.gov (United States)

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community in order to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following three components: data, expertise and tools. The Data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous ECG signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the AHA-BIH Arrhythmia Database, and the CSE database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available to the worldwide scientific community. PMID:20863512

  15. The role of electrocardiography in evaluation of severity of chronic obstructive pulmonary disease in daily clinical practice.

    Science.gov (United States)

    Aktürk, Faruk; Bıyık, İsmail; Kocaş, Cüneyt; Ertürk, Mehmet; Yalçın, Ahmet Arif; Savaş, Ayfer Utku; Kuzer, Firuzan Pınar; Uzun, Fatih; Yıldırım, Aydın; Uslu, Nevzat; Çuhadaroğlu, Çağlar

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) is the fourth leading cause of chronic morbidity and mortality. Bronchial obstruction and increased pulmonary vascular resistance impairs right atrial functions. In this study, we aimed to investigate the effect of bronchial obstruction on p wave axis in patients with COPD and usefulness of electrocardiography (ECG) in the evaluation of the severity of COPD. Ninety five patients (64 male and 31 female) included to the study. Patients were in sinus rhythm, with normal ejection fraction and heart chamber sizes. Their respiratory function tests and 12 lead electrocardiograms were obtained at same day. Correlations with severity of COPD and ECG findings including p wave axis, p wave duration, QRS axis, QRS duration were studied. The mean age was 58 ± 12 years. Their mean p wave axis was 62 ± 18 degrees. In this study, p wave axis has demonstrated significant positive correlations with stages of COPD and QRS axis but significant negative correlations with FEV1, FEF, BMI and QRS duration. P wave axis increases with increasing stages of COPD. Verticalization of the frontal p wave axis may be an early finding of worsening of COPD before occurrences of other ECG changes of hypertrophy and enlargement of right heart chambers such as p pulmonale. Verticalization of the frontal p wave axis reflecting right atrial electrical activity and right heart strain may be a useful parameter for quick estimation of the severity of COPD in an out-patient cared.

  16. [Late arrhythmias in the operated interatrial communication. Analysis of sinus node function and the conduction pathways by His bundle electrocardiography].

    Science.gov (United States)

    Ramírez, A; Gil, M; Martínez Ríos, M A; Cárdenas, M; Pliego, J; Zamora, C; Mata, L A

    1982-01-01

    Four hundred patients with atrial septal defect treated surgically were reviewed. Thirty five (8.7%) developed arrhytmias post-surgery which persisted for over a year. Sinus bradycardia was found in 10 patients, nodal rhythm in 21, and atrial fibrilation and flutter in 4 patients. Thirty five per cent of the patients with late arrhythmias developed related symptomatology. In 14 patients the function of the sinus node was studied with electrical stimulation of the atrium and with His registry. The interatrial conduction time, AV node and His Purkinje were analized employing various stimulation frequencies. All the cases studied had normal intra-atrial conduction; the response of the atrio-ventricular node to increasing frequencies was normal, an the intraventricular conduction remained constant. In 8 patients (52%), alterations of the sinus node were found; these consisted of prolonged post-stimulation pauses, Wenckebach's type sinoatrial block and suppression of sinus automatism employing vagal procedures or through electrical stimulation. A patient with severe bradycardia detected by dynamic electrocardiography had to be treated with a permanent pacemaker. We confirm that these arrhytmias are not produced by lesions of the internodal tracts, and that an alteration of the sinus node is frequent without a concomitant lesion of the intraventricular pathway. The lesion to the nutrient artery could be due to trauma and/or surgically induced. The response to anticholinergic drugs was good. Prolonged observation of these patients could increase the morbility of these arrythmias and raise doubts of the surgical indications in cases with moderate hemodynamic repercussion.

  17. The application of root mean square electrocardiography (RMS ECG) for the detection of acquired and congenital long QT syndrome.

    Science.gov (United States)

    Lux, Robert L; Sower, Christopher Todd; Allen, Nancy; Etheridge, Susan P; Tristani-Firouzi, Martin; Saarel, Elizabeth V

    2014-01-01

    Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS). RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II. All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3. These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements.

  18. High-risk angina patient: identification by clinical features, hospital course, electrocardiography, and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p < 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p < 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup, with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  19. High-risk angina patient. Identification by clinical features, hospital course, electrocardiography and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +/- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p less than 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p less than 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  20. Comparison of prospective electrocardiography-gating high-pitch mode and without electrocardiography-synchronization high-pitch mode acquisition for the image quality and radiation doses of the aortic using dual-source CT

    International Nuclear Information System (INIS)

    Li Jian; Huan Yi; Zhao Hongliang; Wang Ying; Liu Ying; Wei Mengqi; Shi Mingguo; Zheng Minwen

    2013-01-01

    Objective: To evaluate the application of prospective ECG-gating Flash spiral scan mode dual-source CT in aortography, and compare it's image quality and radiation dose with without ECG-synchronization high-pitch spiral scanning mode. Methods: Fifty consecutive patients (Group A) with suspected aortic dissection or after operations for the aortic dissection were scanned with prospective ECG-gated high-pitch scan and another 50 consecutive patients (Group B) were analyzed by non-ECG-gated high-pitch scan. Image quality of the aortic was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. The imaging quality of the aortic and the radiation dose were compared with Mann-whitney U and t test. Results: The average image quality score [(1.18 ± 0.40) in group A and (1.23 ± 0.31) in group B] showed no significant difference between group A and group B (U = 1.20, P = 0.23). The mean radiation dose of group A was lower than that of group B [(1.49 ± 0.38) mSv in group A, (2.79 ± 0.54) mSv in group B, t = 13.677, P < 0.05]. Conclusion: Prospective ECG-gated dual source CT Flash spiral scanning with low radiation dose and good image quality in the aortic dissection with high value of clinical application. (authors)

  1. The effects of sedative music, arousal music, and silence on electrocardiography signals.

    Science.gov (United States)

    Dousty, Mehdy; Daneshvar, Sabalan; Haghjoo, Majid

    2011-01-01

    Research indicates that music can affect heart rate, blood pressure, and skin conductance. Music can stimulate central emotions in the brain and release biochemical materials that change the physiologic state. We sought to compare changes in the electrical function of the heart in response to music. Subjects were asked to listen to 2 types of music, namely, sedative and arousal music, in conjunction with two 30-second periods of complete silence. The experiment was conducted in 4 segments: the first and third parts were silence, and the second and fourth parts were music. First, the response to each type of music was compared with that to the preceding period of silence. Next, the responses to both types of music were compared. Finally, the response to music regardless of the type was compared with that to silence. The amplitude of polarization and depolarization changed in response to different kinds of music. The electrical function of the heart in response to music, irrespective of the music type, differed from that in response to silence. The 2 types of music impacted the electrical function of the heart in different ways: the arousal music influenced T-wave maximum amplitude, whereas no such change was recorded in response to the sedative music. The bandwidth of the polarization and depolarization of the heart rate and R-wave amplitude increased in response to music by comparison with silence. In addition, the heart did not seem to try to synchronize with music. The mean R-wave amplitude in sedative music is higher than the arousal music, so our heart works differently when different types of music are heard. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Three-dimensional surface reconstruction imaging for evaluation of congenital heart disease from ECG-triggered MR images

    International Nuclear Information System (INIS)

    Vannier, M.W.; Laschinger, J.; Knapp, R.H.; Gutierrez, F.R.; Gronnemeyer, S.A.

    1987-01-01

    Three-dimensional surface reconstruction images of the heart and great vessels were produced from contiguous sequences of electrocardiographically triggered MR images in 25 patients with congenital heart disease and in three healthy subjects. The imaging data were semiautomatically processed to separate the epicardial and endocardial surfaces and to define the outline of the enclosed blood volumes on a section by section basis. Images were obtained at 5-mm intervals in patients aged 3 months to 30 years with anomalies of the great vessels, tetralogy of Fallot, septal defects, pulmonary atresia, and other congenital heart malformations. The results were used to facilitate the surgical treatment of these patients and were compared with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. These surface reconstruction images were useful for communicating the results of diagnostic examinations to cardiac surgeons, for sizing and location of intracardiac defects, for imaging the pulmonary venous drainage, and for assessing regional and global function

  3. Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT

    NARCIS (Netherlands)

    Symersky, P.; Habets, J.; Westers, P.; Mol, de B.A.J.M.; Prokop, M.; Budde, R.P.J.

    2012-01-01

    Objectives Multidetector computed tomography (MDCT) has diagnostic value for the evaluation of prosthetic heart valve (PHV) dysfunction but it is hampered by artefacts. We hypothesised that image acquisition using prospective triggering instead of retrospective gating would reduce artefacts related

  4. Non-contact detection of myocardium's mechanical activity by ultrawideband RF-radar and interpretation applying electrocardiography.

    Science.gov (United States)

    Thiel, F; Kreiseler, D; Seifert, F

    2009-11-01

    can potentially be used to support standard electrocardiography (ECG) analysis by complementary information where sole ECG analysis fails, e.g., electromechanical dissociation.

  5. Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease

    International Nuclear Information System (INIS)

    Bailey, I.K.; Griffith, L.S.C.; Rouleau, J.; Strauss, H.W.; Pitt, B.

    1977-01-01

    The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise studies in any of the normal subjects. Fifty-six percent of patients with CAD developed new perfusion defects with exercise compared to 38 percent who developed ischemic ST-segment depression (P < 0.02). However, when chest pain and/or ST depression were considered indices of ischemia, the sensitivity of exercise testing and thallium-201 MPI was similar. The increased sensitivity of MPI compared to ST-segment depression on the ECG was due to patients with baseline ECG abnormalities and those who failed to achieve 85 percent of predicted maximum heart rate with exercise. Analysis of the exercise results according to the extent of coronary artery disease revealed a progressive increase in both positive ECGs and MPI with the number of vessels involved. In patients with single vessel disease the MPI was more sensitive than the ECG (P < 0.02). The combination of the rest and exercise ECG, MPI and chest pain during exercise failed to identify 11 percent of patients with CAD. Exercise thallium-201 MPI is a useful adjunct to conventional exercise testing particularly when evaluating patients with abnormal resting ECGs, those who develop ventricular conduction defects or arrhythmias during exercise, and those who fail to achieve their predicted heart rate because of fatigue or breathlessness

  6. Study design and rationale for biomedical shirt-based electrocardiography monitoring in relevant clinical situations: ECG-shirt study.

    Science.gov (United States)

    Balsam, Paweł; Lodziński, Piotr; Tymińska, Agata; Ozierański, Krzysztof; Januszkiewicz, Łukasz; Główczyńska, Renata; Wesołowska, Katarzyna; Peller, Michał; Pietrzak, Radosław; Książczyk, Tomasz; Borodzicz, Sonia; Kołtowski, Łukasz; Borkowski, Mariusz; Werner, Bożena; Opolski, Grzegorz; Grabowski, Marcin

    2018-01-01

    Today, the main challenge for researchers is to develop new technologies which may help to improve the diagnoses of cardiovascular disease (CVD), thereby reducing healthcare costs and improving the quality of life for patients. This study aims to show the utility of biomedical shirt-based electrocardiography (ECG) monitoring of patients with CVD in different clinical situations using the Nuubo® ECG (nECG) system. An investigator-initiated, multicenter, prospective observational study was carried out in a cardiology (adult and pediatric) and cardiac rehabilitation wards. ECG monitoring was used with the biomedical shirt in the following four independent groups of patients: 1) 30 patients after pulmonary vein isolation (PVI), 2) 30 cardiac resynchronization therapy (CRT) recipients, 3) 120 patients during cardiac rehabilitation after myocardial infarction, and 4) 40 pediatric patients with supraventricular tachycardia (SVT) before electrophysiology study. Approval for all study groups was obtained from the institutional review board. The biomedical shirt captures the electrocardiographic signal via textile electrodes integrated into a garment. The software allows the visualization and analysis of data such as ECG, heart rate, arrhythmia detecting algorithm and relative position of the body is captured by an electronic device. The major advantages of the nECG system are continuous ECG monitoring during daily activities, high quality of ECG recordings, as well as assurance of a proper adherence due to adequate comfort while wearing the shirt. There are only a few studies that have examined wearable systems, especially in pediatric populations. This study is registered in ClinicalTrials.gov: Identifier NCT03068169. (Cardiol J 2018; 25, 1: 52-59).

  7. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  8. Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

    Science.gov (United States)

    Rizos, Timolaos; Güntner, Janina; Jenetzky, Ekkehart; Marquardt, Lars; Reichardt, Christine; Becker, Rüdiger; Reinhardt, Roland; Hepp, Thomas; Kirchhof, Paulus; Aleynichenko, Elena; Ringleb, Peter; Hacke, Werner; Veltkamp, Roland

    2012-10-01

    Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxAF detection. Patients with acute ischemic stroke or transient ischemic attack were prospectively enrolled. After a 12-channel ECG on admission, all patients received 24-hour Holter ECG and CEM. Additionally, ECG monitoring data underwent automated analysis using dedicated software to identify pxAF. Patients with a history of atrial fibrillation or with atrial fibrillation on the admission ECG were excluded. Four hundred ninety-six patients (median age, 69 years; 61.5% male) fulfilled all inclusion criteria (ischemic stroke: 80.4%; transient ischemic attack: 19.6%). Median stroke unit stay lasted 88.8 hours (interquartile range, 65.0-122.0). ECG data for automated CEM analysis were available for a median time of 64.0 hours (43.0-89.8). Paroxysmal AF was documented in 41 of 496 patients (8.3%). Of these, Holter detected pxAF in 34.1%; CEM in 65.9%; and automated CEM in 92.7%. CEM and automated CEM detected significantly more patients with pxAF than Holter (Pstroke on stroke units compared with 24-hour Holter ECG. The comparative usefulness of prolonged or repetitive Holter ECG recordings requires further evaluation.

  9. Non-contact detection of myocardium's mechanical activity by ultrawideband RF-radar and interpretation applying electrocardiography

    Science.gov (United States)

    Thiel, F.; Kreiseler, D.; Seifert, F.

    2009-11-01

    can potentially be used to support standard electrocardiography (ECG) analysis by complementary information where sole ECG analysis fails, e.g., electromechanical dissociation.

  10. A Comparison between Gadofosveset Trisodium and Gadobenate Dimeglumine for Steady State MRA of the Thoracic Vasculature

    Directory of Open Access Journals (Sweden)

    G. Paul Camren

    2014-01-01

    Full Text Available Purpose. Retrospective comparison between gadofosveset trisodium and gadobenate dimeglumine steady state magnetic resonance angiography (SS-MRA of the thoracic vasculature at 1.5T using signal-to-noise ratio (SNR and vessel edge sharpness (ES as markers of image quality. Materials and Methods. IRB approval was obtained. Twenty separate patients each underwent SS-MRA using high-resolution 3D ECG-triggered coronal IR-TFE at 1.5T approximately 3-4 minutes following 10 or 15 mL gadofosveset or 20 mL gadobenate. ROIs were placed in the right atrium, left ventricle, left atrium, ascending aorta, descending aorta, and right pulmonary artery to estimate SNR. Vessel ES was estimated as 20–80% rise distances from line intensity profiles in the left pulmonary vein, ascending aorta, and descending aorta. Data were analyzed using nonpaired Student’s t-test (threshold for significance set at P<0.05. Results. There was no significant difference in mean SNR for the gadofosveset or gadobenate groups (P values: 0.14 to 0.85. There was no significant difference in mean vessel ES for gadofosveset and gadobenate groups (P values: 0.17 to 0.78. Conclusion. High quality thoracic SS-MRA can be achieved with gadobenate dimeglumine, similar to that achieved with the blood pool agent gadofosveset trisodium provided that imaging is initiated quickly (3-4 min after contrast injection.

  11. A comparison between gadofosveset trisodium and gadobenate dimeglumine for steady state MRA of the thoracic vasculature.

    Science.gov (United States)

    Camren, G Paul; Wilson, Gregory J; Bamra, Vikram R; Nguyen, Khahn Q; Hippe, Daniel S; Maki, Jeffrey H

    2014-01-01

    Retrospective comparison between gadofosveset trisodium and gadobenate dimeglumine steady state magnetic resonance angiography (SS-MRA) of the thoracic vasculature at 1.5T using signal-to-noise ratio (SNR) and vessel edge sharpness (ES) as markers of image quality. IRB approval was obtained. Twenty separate patients each underwent SS-MRA using high-resolution 3D ECG-triggered coronal IR-TFE at 1.5T approximately 3-4 minutes following 10 or 15 mL gadofosveset or 20 mL gadobenate. ROIs were placed in the right atrium, left ventricle, left atrium, ascending aorta, descending aorta, and right pulmonary artery to estimate SNR. Vessel ES was estimated as 20-80% rise distances from line intensity profiles in the left pulmonary vein, ascending aorta, and descending aorta. Data were analyzed using nonpaired Student's t-test (threshold for significance set at P < 0.05). There was no significant difference in mean SNR for the gadofosveset or gadobenate groups (P values: 0.14 to 0.85). There was no significant difference in mean vessel ES for gadofosveset and gadobenate groups (P values: 0.17 to 0.78). High quality thoracic SS-MRA can be achieved with gadobenate dimeglumine, similar to that achieved with the blood pool agent gadofosveset trisodium provided that imaging is initiated quickly (3-4 min) after contrast injection.

  12. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    International Nuclear Information System (INIS)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken

    2000-01-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6±14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3±9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280±0.0068 vs ASO group 0.0219±0.0083), and gradually increased with time (1-3 years: 0.0470±0.0157 vs 0.0314±0.0124). (author)

  13. Gender-related differences in clinical presentation, electrocardiography signs, laboratory markers and outcome in patients with acute pulmonary embolism.

    Science.gov (United States)

    Obradović, Slobodan; Džudović, Boris; Rusović, Siniša; Subota, Vesna; Obradović, Dragana

    2016-09-01

    Acute pulmonary embolism (PE) is a potentially life threating event, but there are scarce data about genderrelated differences in this condition. The aim of this study was to identify gender-specific differences in clinical presentation, the diagnosis and outcome between male and female patients with PE. We analysed the data of 144 consecutive patients with PE (50% women) and compared female and male patients regarding clinical presentation, electrocardiography (ECG) signs, basic laboratory markers and six-month outcome. All the patients confirmed PE by visualized thrombus on the multidetector computed tomography with pulmonary angiography (MDCTPA), ECG and echocardiographic examination at admission. Compared to the men, the women were older and a larger proportion of them was in the third tertile of age (66.0% vs 34.0%, p = 0.008). In univariate analysis the men more often had hemoptysis [OR (95% CI) 3.75 (1.16-12.11)], chest pain [OR (95% CI) 3.31 (1.57-7.00)] febrile state [OR (95% CI) 2.41 (1.12-5.22)] and pneumonia at PE presentation [OR (95% CI) 3.40 (1.25-9.22)] and less likely had heart decompensation early in the course of the disease [OR (95%CI) 0.48 (0.24-0.97)]. In the multivariate analysis a significant difference in the rate of pneumonia and acute heart failure between genders disappeared due to strong influence of age. There was no significant difference in the occurrence of typical ECG signs for PE between the genders. Women had higher level of admission glycaemia [7.7 mmol/L (5.5-8.2 mmol/L) vs 6.9 mmol/L (6.3-9.6 mmol/L), p = 0.006] and total number of leukocytes [10.5 x 109/L (8.8-12.7 x 109/L vs 8.7 x 109/L (7.0-11.6 x 109/L)), p = 0.007]. There was a trend toward higher plasma level of brain natriuretic peptide in women compared to men 127.1 pg/mL (55.0-484.0 pg/mL), p = 0.092] vs [90.3 pg/mL (39.2-308.5 pg/mL). The main 6-month outcomes, death and major bleeding, had similar frequencies in both sexes. There are several important differences

  14. Subtraction electrocardiography: Detection of ischemia-induced ST displacement without the need to identify the J point.

    Science.gov (United States)

    Ter Haar, C Cato; Man, Sum-Che; Maan, Arie C; Schalij, Martin J; Swenne, Cees A

    2016-01-01

    When triaging a patient with acute chest pain at first medical contact, an electrocardiogram (ECG) is routinely made and inspected for signs of myocardial ischemia. The guidelines recommend comparison of the acute and an earlier-made ECG, when available. No concrete recommendations for this comparison exist, neither is known how to handle J-point identification difficulties. Here we present a J-point independent method for such a comparison. After conversion to vectorcardiograms, baseline and acute ischemic ECGs after 3minutes of balloon occlusion during elective PCI were compared in 81 patients of the STAFF III ECG database. Baseline vectorcardiograms were subtracted from ischemic vectorcardiograms using either the QRS onsets or the J points as synchronization instants, yielding vector magnitude difference signals, ΔH. Output variables for the J-point synchronized differences were ΔH at the actual J point and at 20, 40, 60 and 80ms thereafter. Output variables for the onset-QRS synchronized differences were the ΔH at 80, 100, 120, 140 and 160ms after onset QRS. Finally, linear regressions of all combinations of ΔHJ+… versus ΔHQRS+… were made, and the best combination was identified. The highest correlation, 0.93 (pJ point and 160ms after the onset of the QRS complex. With a ΔH ischemia threshold of 0.05mV, 66/81 (J-point synchronized differences) and 68/81 (onset-QRS synchronized differences) subjects were above the ischemia threshold, corresponding to sensitivities of 81% and 84%, respectively. Our current study opens an alternative way to detect cardiac ischemia without the need for human expertise for determination of the J point by measuring the difference vector magnitude at 160ms after the onset of the QRS complex. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Diagnosis of acute myocardial infarction in patients undergoing open heart surgery: a comparison of serial myocardial imaging with cardiac enzymes, electrocardiography, and vectocardiography

    International Nuclear Information System (INIS)

    Lowenthal, I.S.; Parisi, A.F.; Tow, D.E.; Barsamian, E.M.; Sasahara, A.A.; McCaughan, D.; Clemson, H.C.

    1977-01-01

    In 44 consecutive patients undergoing elective open heart surgery (OHS), serial electrocardiograms (ECG), vectorcardiograms (VCG), serum CPK, cardiac isoenzymes (CPKMB), and myocardial images using Tc-99m pyrophosphate were obtained, before and after the operation, for the detection of acute myocardial infarction (AMI). Twenty-nine patients developed one or more positive tests postoperatively. Two patients had positive myocardial scintiscans; both had other evidence of infarction. Conversely, the appearance of CPKMB, or new ECG and VCG changes, occurred frequently without evidence of infarction, and were not associated with the development of a positive scintiscan. The results show that false-negative results are infrequent in patients imaged early after OHS, and that cardiac surgical procedures do not cause a high incidence of false-positive scintigrams. Consequently, radionuclide imaging for AMI offers an important adjunct for excluding acute infarction following open heart surgery

  16. Comparative study of thallium-201 single-photon emission computed tomography and electrocardiography in Duchenne and other types of muscular dystrophy

    International Nuclear Information System (INIS)

    Yamamoto, S.; Matsushima, H.; Suzuki, A.; Sotobata, I.; Indo, T.; Matsuoka, Y.

    1988-01-01

    Single-photon emission computed tomography (SPECT) using thallium-201 was compared with 12-lead electrocardiography (ECG) in patients with Duchenne (29), facioscapulohumeral (7), limb-girdle (6) and myotonic (5) dystrophies, by dividing the left ventricular (LV) wall into 5 segments. SPECT showed thallium defects (37 patients, mostly in the posteroapical wall), malrotation (23), apical aneurysm (5) and dilatation (7). ECG showed abnormal QRS (36 patients), particularly as a posterolateral pattern (13). Both methods of assessment were normal in only 7 patients. The Duchenne type frequently showed both a thallium defect (particularly in the posteroapical wall) and an abnormal QRS (predominantly in the posterolateral wall); the 3 other types showed abnormalities over the 5 LV wall segments in both tests. The percent of agreement between the 2 tests was 64, 66, 70, 72 and 72 for the lateral, apical, anteroseptal, posterior and inferior walls, respectively. The 2 tests were discordant in 31% of the LV wall, with SPECT (+) but ECG (-) in 21% (mostly in the apicoinferior wall) and SPECT (-) but ECG (+) in 10% (mostly in the lateral wall). Some patients showed large SPECT hypoperfusion despite minimal electrocardiographic changes. ECG thus appeared to underestimate LV fibrosis and to reflect posteroapical rather than posterolateral dystrophy in its posterolateral QRS pattern. In this disease, extensive SPECT hypoperfusion was also shown, irrespective of clinical subtype and skeletal involvement

  17. Usefulness of electrocardiography-gated dual-source computed tomography for evaluating morphological features of the ventricles in children with complex congenital heart defects

    International Nuclear Information System (INIS)

    Nakagawa, Motoo; Hara, Masaki; Sakurai, Keita; Asano, Miki; Shibamoto, Yuta; Ohashi, Kazuya

    2011-01-01

    Improved time resolution using dual-source computed tomography (DSCT) enabled adaptation of electrocardiography (ECG)-gated cardiac CT for children with a high heart rate. In this study, we evaluated the ability of ECG-gated DSCT (ECG-DSCT) to depict the morphological ventricular features in patients with congenital heart disease (CHD). Between August 2006 and March 2010, a total of 66 patients with CHD (aged 1 day to 9 years, median 11 months) were analyzed using ECG-DSCT. The type of anomaly was ventricular septal defect (VSD) in 32 (malaligned type in 20, perimembranous type in 7, supracristal type in 3, muscular type in 2), single ventricle (SV) in 11, and corrected transposition of the great arteries (cTGA) in 3. All patients underwent ECG-DSCT and ultrasonography (US). We evaluated the accuracy of diagnosing the type of VSD. For the cases with SV and cTGA, we evaluated the ability to depict anatomical ventricular features. In all 32 cases of VSD, DSCT could confirm the VSD defects, and the findings were identical to those obtained by US. Anatomical configurations of the SV and cTGA were correctly diagnosed, similar to that on US. Our study suggests that ECG-DSCT can clearly depict the configuration of ventricles. (author)

  18. Coronary computed tomography angiography using prospective electrocardiography-gated axial scans with 64-detector computed tomography. Evaluation of stair-step artifacts and padding time

    International Nuclear Information System (INIS)

    Kimura, Fumiko; Umezawa, Tatsuo; Asano, Tomonari; Chihara, Ruri; Nishi, Naoko; Nishimura, Shigeyoshi; Sakai, Fumikazu

    2010-01-01

    We compared stair-step artifacts and radiation dose between prospective electrocardiography (ECG)-gated coronary computed tomography angiography (prospective CCTA) and retrospective CCTA using 64-detector CT and determined the optimal padding time (PT) for prospective CCTA. We retrospectively evaluated 183 patients [mean heart rate (HR) <65 beats/min, maximum HR instability <5 beats/min] who had undergone CCTA. We scored stair-step artifacts from 1 (severe) to 5 (none) and evaluated the effective dose in 53 patients with retrospective CCTA and 130 with prospective CCTA (PT 200 ms, n=32; PT 50 ms, n=98). Mean artifact scores were 4.3 in both retrospective and prospective CCTAs. However, statistically more arteries scored <3 (nonassessable) on prospective CCTA (P<0.001). Mean scores for prospective CCTA with 200- and 50-ms PT were 4.1 and 4.3, respectively (no significant difference). The radiation dose of prospective CCTA was reduced by 59.1% to 80.7%. Prospective CCTA reduces the radiation dose and allows diagnostic imaging in most cases but shows more nonevaluable artifacts than retrospective CCTA. Use of 50-ms instead of 200-ms PT appears to maintain image quality in patients with a mean HR <65 beats/min and HR instability of <5 beats/min. (author)

  19. Bayesian comparison of cost-effectiveness of different clinical approaches to diagnose coronary artery disease

    International Nuclear Information System (INIS)

    Patterson, R.E.; Eng, C.; Horowitz, S.F.; Gorlin, R.; Goldstein, S.R.

    1984-01-01

    The objective of this study was to compare the cost-effectiveness of four clinical policies (policies I to IV) in the diagnosis of the presence or absence of coronary artery disease. A model based on Bayes theorem and published clinical data was constructed to make these comparisons. Effectiveness was defined as either the number of patients with coronary disease diagnosed or as the number of quality-adjusted life years extended by therapy after the diagnosis of coronary disease. The following conclusions arise strictly from analysis of the model and may not necessarily be applicable to all situations. As prevalence of coronary disease in the population increased, it caused a linear increase in cost per patient tested, but a hyperbolic decrease in cost per effect, that is, increased cost-effectiveness. Thus, cost-effectiveness of all policies (I to IV) was poor in populations with a prevalence of disease below 10%. Analysis of the model also indicates that at prevalences less than 80%, exercise thallium scintigraphy alone as a first test (policy II) is a more cost-effective initial test than is exercise electrocardiography alone as a first test (policy I) or exercise electrocardiography first combined with thallium imaging as a second test (policy IV). Exercise electrocardiography before thallium imaging (policy IV) is more cost-effective than exercise electrocardiography alone (policy I) at prevalences less than 80%. 4) Noninvasive exercise testing before angiography (policies I, II and IV) is more cost-effective than using coronary angiography as the first and only test (policy III) at prevalences less than 80%. 5) Above a threshold value of prevalence of 80% (for example patients with typical angina), proceeding to angiography as the first test (policy III) was more cost-effective than initial noninvasive exercise tests (policies I, II and IV)

  20. Performance of Thallium-201 Electrocardiography-gated Myocardial Perfusion Single Photon Emission Computed Tomography to Assess Left Ventricular Function

    Directory of Open Access Journals (Sweden)

    Guang-Uei Hung

    2005-05-01

    Full Text Available This study evaluated the performance of gated single photon emission computed tomography (SPECT with thallium-201 (201Tl in assessing left ventricular ejection fraction (LVEF, end-diastolic volume (EDV, and end-systolic volume (ESV in Taiwanese by determining repeatability and correlation with two-dimensional (2D echocardiography. A total of 18 patients underwent two sequential gated SPECT acquisitions within 30 minutes in the resting state to assess repeatability. Another 28 patients who underwent gated SPECT and 2D echocardiography within 7 days were included for comparison. The two sequential measurements were well correlated with respect to LVEF, EDV, and ESV (r = 0.97, 0.95, and 0.97, respectively, all p < 0.0001. Bland-Altman analysis revealed that two standard deviations of the absolute difference between the two sequential measurements for LVEF, EDV, and ESV were 6.4%, 16.8 mL, and 8.6 mL, respectively. For LVEF, EDV, and ESV, correlations between redistribution 201Tl-gated SPECT and echocardiography were also excellent (all r = 0.83, p < 0.0001. LVEF was similar with 201Tl-gated SPECT and echocardiography, but EDV and ESV were significantly higher with echocardiography (p < 0.05. Our study revealed that 201Tl-gated SPECT has high repeatability and excellent correlation with echocardiography for the assessment of LVEF and volumes in Taiwanese. These results support the clinical application of gated SPECT in routine 201Tl myocardial perfusion imaging in Taiwanese.

  1. Computerized electrocardiography in American pit bull terrier dogsEletrocardiografia computadorizada em cães da raça American pit bull terrier

    Directory of Open Access Journals (Sweden)

    Mauro José Lahm Cardoso

    2013-10-01

    Full Text Available Electrocardiography (ECG is an essential examination for evaluation of patient with heart disease is great importance the diagnosis of arrhythmias. The examination can determine source f rhythm and frequency depolarization heart, providing information in clinical status myocardium, since deflections P-QRS-T tracing can be altered by disease or physiological factor. With advancement of computer technology, computerized electrocardiography has been used in human medicine as auxiliary diagnostic method and currently is being increasingly used in veterinary medicine. The objectives this study were to study e computerized electrocardiographic parameters in dogs breed American Pit Bull Terrier, comparing them with patterns species. In present study, we evaluated electrocardiographic examinations 42 dogs the breed American Pit Bull clinically healthy, 22 males and 20 females, aged between 1 and 6 years. Sinus rhythm was observed in 57% of dogs showed sinus rhythm and only 26% were wandering pacemaker. The electrocardiographic values obtained from these dogs computerized ECG were within the normal range of species, except the duration of the P wave which had longer than 0.04 seconds in 24% of dogs. We conclude that the dogs of the breed American Pit Bull Terrier have the same electrocardiographic values obtained in other breeds by the computerized method, except for the increase in P-wave duration. A eletrocardiografia (ECG é um exame essencial para avaliação do paciente com doença cardíaca, sendo de grande importância para o diagnóstico das arritmias. O exame pode determinar a origem do ritmo e a freqüência de despolarização do coração, fornecendo informações do estado clínico do miocárdio, uma vez que as deflexões P-QRS-T do traçado podem ser alteradas por uma enfermidade ou fator fisiológico. Com o avanço da informática, a eletrocardiografia computadorizada tem sido utilizada na medicina humana e veterinária como método de

  2. Usefulness of exercise electrocardiography and thallium scintigraphy in unstable angina pectoris in predicting the extent and severity of coronary artery disease

    International Nuclear Information System (INIS)

    Freeman, M.R.; Chisholm, R.J.; Armstrong, P.W.

    1988-01-01

    The safety and efficacy of exercise electrocardiography and thallium scintigraphy early in the course of unstable angina pectoris were assessed 4.6 +/- 1.6 days after admission in 67 patients with unstable angina that stabilized after medical therapy. Coronary arteriography was performed in all patients 5.4 +/- 2.4 days after admission. There was no difference in clinical, exercise or scintigraphic variables between patients with stenoses less than 50% and patients with 1-vessel coronary artery disease (CAD) defined as a diameter stenosis greater than or equal to 50%. Patients with 3-vessel CAD had a significantly shorter exercise duration than patients with less than 50%-diameter narrowing (5.5 +/- 2.2 vs 8.3 +/- 3.3 minutes, respectively), lower exercise heart rate (119 +/- 20 vs 149 +/- 22 beats/min) and systolic blood pressure (156 +/- 29 vs 166 +/- 33 mm Hg), more frequent chest pain (76 vs 20%) and more pronounced ST depression (-1.48 +/- 1.37 vs -0.33 +/- 0.72 mm). In addition, thallium defect size on exercise was greater in the patients with 2-vessel CAD (159 +/- 132 degrees) and 3-vessel CAD (255 +/- 132 degrees) than in patients with no CAD (28 +/- 319 degrees) or 1-vessel CAD (73 +/- 78 degrees), p greater than or equal to 0.05. Multiple regression analysis demonstrated that thallium defect size was the best predictor of extent of CAD, with exercise heart rate and presence of chest pain during exercise also predictive of extent of CAD

  3. Diagnostic performance of coronary computed tomography angiography versus exercise electrocardiography for coronary artery disease: a systematic review and meta-analysis.

    Science.gov (United States)

    Yin, Xinxin; Wang, Jiali; Zheng, Wen; Ma, Jingjing; Hao, Panpan; Chen, Yuguo

    2016-07-01

    Both coronary computed tomography angiography (CCTA) and exercise electrocardiography (ExECG) are non-invasive testing methods for the evaluation of coronary artery disease (CAD). However, there was controversy on the diagnostic performance of these methods due to the limited data in each single study. Therefore, we performed a meta-analysis to address these issues. We searched PubMed and Embase databases up to May 22, 2015. Two authors identified eligible studies, extracted data and accessed quality. Pooled estimation of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), summary receiver-operating characteristic curve (SROC) and the area under curve (AUC) of CCTA and ExECG for the diagnosis of CAD were calculated using Stata, Meta-Disc and Review Manager statistical software. Seven articles were included. Pooled sensitivity of CCTA and ExECG were 0.98 [95% confidence intervals (CIs): 0.95-0.99] and 0.66 (95% CIs: 0.59-0.72); pooled specificity of CCTA and ExECG were 0.84 (95% CIs: 0.81-0.87) and 0.75 (95% CIs: 0.71-0.79); pooled DOR of CCTA and ExECG were 110.24 (95% CIs: 35.07-346.55) and 6.28 (95% CIs: 2.06-19.13); and AUC of CCTA and ExECG were 0.9950±0.0046 and 0.7727±0.0638, respectively. There is no heterogeneity caused by threshold effect in CCTA or ExECG analysis. The Deeks' test showed no potential publication bias (P=0.17). CCTA has better diagnostic performance than ExECG in the evaluation of CAD, which can provide a better solution for the clinical problem of the diagnosis for CAD.

  4. Incremental value of clinical assessment, supine exercise electrocardiography, and biplane exercise radionuclide ventriculography in the prediction of coronary artery disease in men with chest pain

    International Nuclear Information System (INIS)

    Currie, P.J.; Kelly, M.J.; Harper, R.W.; Federman, J.; Kalff, V.; Anderson, S.T.; Pitt, A.

    1983-01-01

    The incremental value of clinical assessment, exercise electrocardiography (ECG) and biplane radionuclide ventriculography (RVG) in the prediction of coronary artery disease (CAD) was assessed in 105 men without myocardial infarction who were undergoing coronary angiography for investigation of chest pain. Independent clinical assessment of chest pain was made prospectively by 2 physicians. Graded supine bicycle exercise testing was symptom-limited. Right anterior oblique ECG-gated first-pass RVG and left anterior oblique ECG-gated equilibrium RVG were performed at rest and exercise. Regional wall motion abnormalities were defined by agreement of 2 of 3 blinded observers. A combined strongly positive exercise ECG response was defined as greater than or equal to 2 mm ST depression or 1.0 to 1.9 mm ST depression with exercise-induced chest pain. A multivariate logistic regression model for the preexercise prediction of CAD was derived from the clinical data and selected 2 variables: chest pain class and cholesterol level. A second model assessed the incremental value of the exercise test in prediction of CAD and found 2 exercise variables that improved prediction: RVG wall motion abnormalities, and a combined strongly positive ECG response. Applying the derived predictive models, 37 of the 58 patients (64%) with preexercise probabilities of 10 to 90% crossed either below the 10% probability threshold or above the 90% threshold and 28 (48%) also moved across the 5 and 95% thresholds. Supine exercise testing with ECG and biplane RVG together, but neither test alone, effectively adds to clinical prediction of CAD. It is most useful in men with atypical chest pain and when the ECG and RVG results are concordant

  5. ECG-triggered {sup 18}F-fluorodeoxyglucose positron emission tomography imaging of the rat heart is dramatically enhanced by acipimox

    Energy Technology Data Exchange (ETDEWEB)

    Poussier, Sylvain [Experimental Imaging Platform, Nancyclotep, Nancy (France); CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancy University, Faculty of Medicine, Nancy (France); Hopital de Brabois, Nancyclotep, Service de Medecine Nucleaire, Vandoeuvre-les-Nancy (France); Maskali, Fatiha [Experimental Imaging Platform, Nancyclotep, Nancy (France); CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Tran, Nguyen [Nancy University, Faculty of Medicine, Nancy (France); Surgery School, Faculty of Medicine, Nancy (France); INSERM U961, Nancy (France); Person, Christophe; Boutley, Henri; Karcher, Gilles [Experimental Imaging Platform, Nancyclotep, Nancy (France); CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancy University, Faculty of Medicine, Nancy (France); Maureira, Pablo [Nancy University, Faculty of Medicine, Nancy (France); Surgery School, Faculty of Medicine, Nancy (France); CHU-Nancy, Department of Cardiac Surgery, Nancy (France); Lacolley, Patrick; Regnault, Veronique [Nancy University, Faculty of Medicine, Nancy (France); INSERM U961, Nancy (France); Fay, Renaud [Centre d' Investigation Clinique, INSERM, U9501, Nancy (France); Marie, Pierre Yves [Experimental Imaging Platform, Nancyclotep, Nancy (France); CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancy University, Faculty of Medicine, Nancy (France); INSERM U961, Nancy (France)

    2010-09-15

    {sup 18}F-Fluorodeoxyglucose (FDG) imaging, provided by current positron emission tomography (PET) systems dedicated to small animals, might provide a precise functional assessment of the left ventricle (LV) in rats, although conventional metabolic conditioning by hyperinsulinaemic glucose clamping is not well adapted to this setting. This study was aimed at assessing cardiac FDG PET in rats pre-medicated with acipimox, a potent nicotinic acid derivative yielding comparable image quality to clamping in man. Metabolic conditioning was compared in Wistar rats between a conventional oral glucose loading (1.5 mg/kg) and acipimox, which was given at high but well tolerated doses subcutaneously (25 mg/kg) or orally (50 mg/kg). Myocardial to blood (M/B) activity ratio and myocardial signal to noise (S/N) ratio were analysed on gated FDG PET images. The S/N ratio of the gated cardiac images evolved in parallel with the M/B activity ratio and these two ratios were independently enhanced by glucose loading and acipimox. However, these enhancements were: (1) dramatic for acipimox, especially for the high oral dose of 50 mg/kg (from 2.85 {+-} 0.57 to 10.73 {+-} 0.54 for the M/B ratio of rats with or without glucose loading; p < 0.0001) and (2) much more limited for glucose loading (from 6.61 {+-} 0.49 to 7.89 {+-} 0.41 for the M/B ratio of rats with or without acipimox administration; p = 0.049). With the high oral dose of acipimox, the gated cardiac FDG PET images had very high S/N ratios, at least equivalent to those currently documented in man. Metabolic conditioning by oral doses of acipimox is highly efficient for experimental studies planned with cardiac FDG PET in rats. (orig.)

  6. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  7. Evaluation of the indications and arrhythmic patterns of 24 hour Holter electrocardiography among hypertensive and diabetic patients seen at OAUTHC, Ile-Ife Nigeria

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2014-11-01

    premature ventricular contractions were the commonest arrhythmic pattern among our patients. HRV was reduced in T2DM patients compared with hypertensive patients. Keywords: Holter electrocardiography, arrhythmias, hypertension, diabetes mellitus, Nigerians

  8. Influence of the trigger technique on ventricular function measurements using 3-Tesla magnetic resonance imaging: comparison of ECG versus pulse wave triggering

    International Nuclear Information System (INIS)

    Sievers, Burkhard; Wiesner, Marco; Kiria, Nino; Speiser, Uwe; Schoen, Steffen; Strasser, Ruth H.

    2011-01-01

    Background Three Tesla cardiovascular magnetic resonance imaging (3T-CMR) is increasingly used in clinical practice. Despite many advantages one drawback is that ECG signal disturbances and artifacts increase with higher magnetic field strength resulting in trigger problems and false gating. This particularly affects cardiac imaging because most pulse sequences require ECG triggering. Pulse wave (PW) triggering is robust and might have advantages over ECG triggering. Purpose To evaluate differences in left ventricular (LV) function as an integral part of most CMR studies between ECG- and PW-triggered short-axis imaging using 3T-CMR. Material and Methods Forty-three patients underwent multiple short-axis cine imaging for LV-function assessment with ECG and PW triggering using standard multi breath hold steady-state free precession. LV-volumes (EDV, ESV), ejection fraction (EF), and mass were determined by slice summation. LV-wall motion was assessed by using a 4-point scoring scale. Bland Altman statistics for inter-observer variability were performed. Results ECG triggering failed in 15 patients (34.8%). Thus, analysis was performed in 28 patients (13 with impaired LV function). Difference in volumes (EDV 0.13 ± 1.8 mL, ESV 0.59 ± 1.1 mL), EF (-0.32 ± 0.6%) and mass (0.01 ± 1.1 g) between ECG and PW triggering were very small and significant only for ESV and EF (p 0.011). In patients with impaired LV function (n = 19) differences were not significant (p = 0.128). Wall motion scores did not differ between ECG and PW triggering (p = 0.295). Inter-observer variability for function measurements was low. Conclusion Short-axis cine imaging for LV-function assessment can accurately be performed using PW triggering on 3T magnets, and may be used in clinical practice when ECG triggering is disturbed

  9. Interchangeability of electrocardiography and blood pressure measurement for determining heart rate and heart rate variability in free-moving domestic pigs in various behavioral contexts

    Directory of Open Access Journals (Sweden)

    Annika eKrause

    2015-11-01

    Full Text Available This study assessed the interchangeability between heart rate (HR and heart rate variability (HRV measures derived from a series of interbeat intervals (IBIs recorded via electrocardiogram (ECG and intra-arterial blood pressure (BP in various behavioral contexts. Five minutes of simultaneously recorded IBIs from ECG and BP signals in 11 female domestic pigs during resting, feeding and active behavior were analyzed. Comparisons were made for measures of HR, SDNN (the standard deviation of IBIs and RMSSD (the root mean of the squared distances of subsequent IBIs derived from ECG and BP signals for each behavior category using statistical procedures with different explanatory power (linear regression, intraclass correlation coefficient (ICC, Bland and Altman plots and analysis of variance (ANOVA. Linear regression showed a strong relationship for HR during all behaviors and for HRV during resting. Excellent ICCs (lower 95% CI > 0.75 and narrow limits of agreement (LoA in all behavior categories were found for HR. ICCs for HRV reached the critical lower 95% CI value of 0.75 only during resting. Using Bland and Altman plots, HRV agreement was unacceptable for all of the behavior categories. ANOVA showed significant differences between the methods in terms of HRV. BP systematically overestimated HRV compared with ECG. Our findings reveal that HR data recorded via BP agree well those recorded using ECG independently of the activity of the subject, whereas ECG and BP cannot be used interchangeably in the context of HRV in free-moving domestic pigs.

  10. A combination of troponin T and 12-lead electrocardiography: a valuable tool for early prediction of long-term mortality in patients with chest pain without ST-segment elevation.

    Science.gov (United States)

    Jernberg, Tomas; Lindahl, Bertil

    2002-11-01

    Electrocardiography (ECG) obtained on admission and a troponin T (tn-T) level measured early after admission are simple and accessible methods for predicting outcome in patients with suspected unstable angina or myocardial infarction without persistent ST-elevations. However, there are few studies about the combination of these 2 methods as a means of predicting long-term outcome. ECG was obtained on admission, and a tn-T level was analyzed on admission and after 6 hours in 710 consecutive patients admitted because of chest pain and no ST-elevations. Patients were observed for a median time of 40 months for death. ST-segment depressions > or =0.05 mV were present in 266 patients (37%). These patients had a 9.7-fold increased risk of death, compared with patients with normal ECG results. Isolated T-Wave inversions or pathological signs other than ST-T changes were present in 196 patients (28%), who had a 4.5-fold increased risk of death compared with patients who had normal ECG results. At 6 hours after admission, 169 patients (24%) had at least 1 sample of tn-T > or =0.10 microg/L, which resulted in an 3.7-fold increased risk of death. In a multivariate analysis, both ECG on admission and tn-T level came out as independent predictors of outcome. When these methods were combined, patients could be divided into low- (tn-T level or =0.10 microg/L or ST-segment depression), and high-risk groups (tn-T level > or =0.10 microg/L and ST-segment depression). ECG and tn-T level are valuable tools to quickly risk stratify patients with chest pain. The combination of these methods is superior to either one alone.

  11. Single Doses up to 800 mg of E-52862 Do Not Prolong the QTc Interval--A Retrospective Validation by Pharmacokinetic-Pharmacodynamic Modelling of Electrocardiography Data Utilising the Effects of a Meal on QTc to Demonstrate ECG Assay Sensitivity.

    Science.gov (United States)

    Täubel, Jörg; Ferber, Georg; Lorch, Ulrike; Wang, Duolao; Sust, Mariano; Camm, A John

    2015-01-01

    E-52862 is a Sigma-1 receptor antagonist (S1RA) currently under investigation as a potential analgesic medicine. We successfully applied a concentration-effect model retrospectively to a four-way crossover Phase I single ascending dose study and utilized the QTc shortening effects of a meal to demonstrate assay sensitivity by establishing the time course effects from baseline in all four periods, independently from any potential drug effects. Thirty two healthy male and female subjects were included in four treatment periods to receive single ascending doses of 500 mg, 600 mg or 800 mg of E-52862 or placebo. PK was linear over the dose range investigated and doses up to 600 mg were well tolerated. The baseline electrocardiography (ECG) measurements on Day-1 were time-matched with ECG and pharmacokinetic (PK) samples on Day 1 (dosing day). In this conventional mean change to time-matched placebo analysis, the largest time-matched difference to placebo QTcI was 1.44 ms (90% CI: -4.04, 6.93 ms) for 500 mg; -0.39 ms (90% CI: -3.91, 3.13 ms) for 600 mg and 1.32 ms (90% CI: -1.89, 4.53 ms) for 800 mg of E-52862, thereby showing the absence of any QTc prolonging effect at the doses tested. In addition concentration-effect models, one based on the placebo corrected change from baseline and one for the change of QTcI from average baseline with time as fixed effect were fitted to the data confirming the results of the time course analysis. The sensitivity of this study to detect small changes in the QTc interval was confirmed by demonstrating a shortening of QTcF of -8.1 (90% CI: -10.4, -5.9) one hour and -7.2 (90% CI: -9.4, -5.0) three hours after a standardised meal. EU Clinical Trials Register EudraCT 2010 020343 13.

  12. Screening for Coronary Heart Disease with Electrocardiography

    Science.gov (United States)

    ... resting and completely still or while you are exercising. ECG is used to see whether the heart is beating and functioning normally. Potential Benefits and Harms The Task Force reviewed evidence to ...

  13. Electrocardiography of Grevy's zebras (Equus grevyi).

    Science.gov (United States)

    Myers, Debbie A; Citino, Scott; Mitchell, Mark A

    2008-09-01

    Electrocardiograms (ECGs) are a good baseline test for assessing cardiac rhythm. ECGs have not been reported in any zebra species and in very few Perissodactyla species. Standard limb, six-lead ECGs were recorded in 23 anesthetized Grevy's zebras (Equus grevyi). Heart rate, RR interval, P-wave duration, RR maximum/minimum, PR interval, QRS duration, QT interval, ST segment deviation, P-wave amplitude, QRS amplitude, and T-wave amplitude were measured and calculated from lead II ECGs from these Grevy's zebras. Several variables were tested, including gender, age (0-24, 24-48, 48-180, and >180 mo), weight (350 kg), pregnancy status, and anesthetic differences (standard dose or supplemented dose), to see if they affected ECG values in these animals. There were no significant differences in any of the ECG parameters between genders. RR and QT intervals were longer in older zebras; heart rates were faster in younger zebras. The RR and PR intervals, as well as the QRS duration, were greater in heavier zebras; heart rates were faster in lighter zebras. The RR interval was significantly longer in pregnant zebras. There were no significant differences in any of the ECG parameters for zebras anesthetized with a standardized dose of the drug combination etorphine-detomidine-acepromazine compared to those receiving additional supplements of these drugs and/or ketamine. All other parameters were not significantly different among groups, except where noted previously. The results of this research indicate that differences in ECG parameters in zebras may occur between animals of different ages, weights, and pregnancy status and that these factors should be considered when interpreting the respective ECGs of these zebras.

  14. The Use of Fetal Noninvasive Electrocardiography

    Directory of Open Access Journals (Sweden)

    Igor Lakhno

    2016-01-01

    Full Text Available Preeclampsia (PE is one of the severe complications of pregnancy that leads to fetal deterioration. The aim was to survey the validity of fetal distress diagnostics in case of Doppler ultrasonic umbilical vein and arteries blood flow velocity investigation and ECG parameters analysis obtained from maternal abdominal signal before labor in preeclamptic patients. Fetal noninvasive ECG and umbilical arterial and venous Doppler investigation were performed in 120 patients at 34–40 weeks of gestation. And 30 of them had physiological gestation and were involved in Group I. In Group II 52 pregnant women with mild-moderate PE were observed. 38 patients with severe PE were monitored in Group III. The most considerable negative correlation was determined in pair Apgar score 1 versus T/QRS (R=-0.50; p<0.05. So the increased T/QRS ratio was the most evident marker of fetal distress. Fetal noninvasive ECG showed sensitivity of 96.6% and specificity of 98.4% and, therefore, was determined as more accurate method for fetal monitoring.

  15. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    International Nuclear Information System (INIS)

    Di Cesare, Ernesto; Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra; Gravina, Giovanni Luca; Masciocchi, Carlo

    2015-01-01

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  16. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy); Gravina, Giovanni Luca [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Masciocchi, Carlo [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy)

    2015-04-15

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  17. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.

    Science.gov (United States)

    Hell, Michaela M; Bittner, Daniel; Schuhbaeck, Annika; Muschiol, Gerd; Brand, Michael; Lell, Michael; Uder, Michael; Achenbach, Stephan; Marwan, Mohamed

    2014-01-01

    Low tube voltage reduces radiation exposure in coronary CT angiography (CTA). Using 70 kVp tube potential has so far not been possible because CT systems were unable to provide sufficiently high tube current with low voltage. We evaluated feasibility, image quality (IQ), and radiation dose of coronary CTA using a third-generation dual-source CT system capable of producing 450 mAs tube current at 70 kVp tube voltage. Coronary CTA was performed in 26 consecutive patients with suspected coronary artery disease, selected for body weight Image noise was lower in IR vs FBP (60 ± 10 HU vs 74 ± 8 HU; P < .001). In patients <100 kg and with a regular heart rate <60 beats/min, third-generation dual-source CT using high-pitch spiral acquisition and 70 kVp tube voltage is feasible and provides both robust IQ and very low radiation exposure. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  18. High-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxer dogs Eletrocardiografia de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito em cães da raça Boxer

    Directory of Open Access Journals (Sweden)

    Evandro Zacché Pereira

    2013-06-01

    Full Text Available To evaluate the reliability of high-resolution electrocardiography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers, 20 dogs with no structural cardiac alterations at echocardiographic examination were grouped on the basis of frequency of ventricular arrhythmias, evaluated by 24-hour ambulatory ECG, and undergoing a high-resolution electrocardiography. High frequency QRS duration, duration of terminal QRS complex less than 40µV (LAS40 and root mean square voltage of the terminal 40 milliseconds of the QRS complex (RMS40 were measured. Differences in high-resolution ECG variables were not observed between groups. Therefore, the results of this investigation suggest that high-resolution electrocardiography is not a useful method for the diagnosis of arrhythmogenic right ventricular cardiomyopathy in Boxers without detectable myocardial alterations or systolic dysfunction.Com o objetivo de avaliar a importância da eletrocardiografia de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito do Boxer, 20 cães sem evidências de doença cardíaca estrutural à avaliação ecodopplercardiográfica foram agrupados de acordo com a frequência de arritmias ventriculares, avaliadas pela eletrocardiografia ambulatorial de 24 horas, e submetidos ao exame eletrocardiográfico de alta resolução. Duração do complexo QRS filtrado, duração dos sinais de baixa amplitude (menor que 40µV dos últimos 40 milissegundos do complexo QRS e raiz quadrada média da voltagem ao quadrado dos últimos 40 milissegundos do complexo QRS (RMS40 foram as variáveis avaliadas. Não foram observadas diferenças significativas entre os grupos em relação às variáveis estudadas. Sendo assim, os resultados do presente estudo sugerem que a eletrocardiografia de alta resolução não é uma ferramenta útil no auxílio diagnóstico da cardiomiopatia arritmogênica do ventrículo direito dos cães da raça Boxer

  19. A direct comparison of efficacy between desloratadine and rupatadine in seasonal allergic rhinoconjunctivitis: a randomized, double-blind, placebo-controlled study.

    Science.gov (United States)

    Lukat, Kf; Rivas, P; Roger, A; Kowalski, Ml; Botzen, U; Wessel, F; Sanquer, F; Agache, I; Izquierdo, I

    2013-01-01

    H1-antihistamines are recommended as the first-line symptomatic treatment of allergic rhinitis. The objective of this study was to evaluate the effects of rupatadine (RUP) versus desloratadine (DES) in subjects with seasonal allergic rhinitis (SAR). To assess the efficacy and safety of RUP in SAR in comparison with placebo (PL) and DES. A randomized, double-blind, multicenter, international, and PL-controlled study was carried out. The main selection criteria included SAR patients over 12 years old with a positive prick test to a relevant seasonal allergen for the geographic area. Symptomatic patients at screening with a nasal symptom sum score of ≥6 points (nasal discharge, nasal obstruction, sneezing, and nasal pruritus), a non-nasal score of ≥3 points (ocular pruritus, ocular redness, and tearing eyes), and a rhinorrhea score of ≥2 points with laboratory test results and electrocardiography within acceptable limits were included in the study. Change from baseline in the total symptom-score (T7SS) over the 4-week treatment period (reflective evaluation) was considered the primary efficacy variable. Secondary efficacy measures included total nasal symptom score (T4NSS) and conjunctival symptom score (T3NNSS), both of which are reflective and instantaneous evaluations. Furthermore questions related to quality of life (eg, sleep disturbances or impairment of daily activities) have also been evaluated. Safety was assessed according to adverse events reported, as well as laboratory and electrocardiography controls. A total of 379 patients were randomized, of which 356 were included and allocated to PL (n = 122), RUP (n = 117), or DES (n = 117). Mean change of T7SS over the 4-week treatment period was significantly reduced in the RUP (-46.1%, P = 0.03) and DES (-48.9%, P = 0.01) groups, compared with PL. Similarly, RUP and DES were comparable and significantly superior to PL for all secondary endpoints, including nasal and conjunctival symptoms and patients' and

  20. Comparing twelve-lead electrocardiography with close-to-heart patch based electrocardiography

    DEFF Research Database (Denmark)

    Hansen, Ingeborg Helbech; Hoppe, Karsten; Gjerde, Anna

    2015-01-01

    used in the clinic impeding clinical interpretation. In this study, recordings from an ePatch® lead system involving three torso sites are compared with concurrently recorded standard 12-lead ECG. Pearson's correlation coefficients (CC) of −0.90 and 0.91 is found between two of the PEM signals...

  1. Propofol-cetamina racêmica e propofol-cetamina levógira em cadelas: parâmetros eletrocardiográficos e outras variáveis fisiológicas Propofol-racemic ketamine or propofol-levogire ketamine in dogs: effects on electrocardiography and other physiological parameters

    Directory of Open Access Journals (Sweden)

    R.M. Almeida

    2008-12-01

    Full Text Available Estudaram-se os efeitos da infusão contínua da associação propofol e cetamina sobre variáveis fisiológicas e eletrocardiográficas e sua possível analgesia em 12 cadelas. Após indução com propofol, os animais receberam 0,4mg/kg/min de propofol + 0,2mg/kg/min de cetamina racêmica (n = 6, grupo PC ou 0,4mg/kg/min de propofol + 0,1mg/kg/min de cetamina S+ (n = 6, grupo PCS. Avaliaram-se: teste álgico, freqüência cardíaca (FC, parâmetros eletrocardiográficos, freqüência respiratória (FR, pressão arterial sistólica, média e diastólica (PAS, PAM, PAD, saturação da oxiemoglobina (SpO2 e temperatura retal (TR. Houve elevação da FC sem alterações eletrocardiográficas, com exceção de aumento na amplitude da onda T em um animal de cada grupo. A FR diminuiu, e os valores de SpO2 ficaram abaixo de 90% em alguns momentos nos dois grupos. PAS, PAM e PAD diminuíram, mas não houve diferença entre os protocolos. Não se observou analgesia em sete animais, três cadelas apresentaram analgesia discreta, e apenas duas demonstraram analgesia favorável. Conclui-se que os protocolos são seguros em cadelas, contudo não há analgesia suficiente para procedimento cirúrgico. As alterações eletrocardiográficas foram relacionadas à FC e à amplitude de onda T, sendo esta sugestiva de hipóxia do miocárdio.The effects of propofol and ketamine on physiological parameters, electrocardiography, and analgesia were evaluated in twelve dogs that received propofol-ketamine (0.4mg/kg/min + 0.2mg/kg/min, n=6, PK group or propofol-S+ketamine (0.4mg/kg/min + 0.1mg/kg/min, n=6, PKS group after induction of anesthesia with propofol (8.0mg/kg. Assessments of pain; heart rate (HR; electrocardiography (ECG; respiratory rate (RR; systolic, medium, and diastolic arterial pressures (SAP, MAP, DAP; saturation of hemoglobin (SpO2; and rectal temperature (RT were conducted. There was a rise in HR with no electrocardiographically changes, but an increase

  2. Pulse wave as an alternate signal for data synchronization during gated myocardial perfusion SPECT imaging.

    Science.gov (United States)

    Lang, Otto; Trojanova, Helena; Balon, Helena R; Kunikova, Ivana; Bilwachs, Milos; Penicka, Martin; Kaminek, Milan; Myslivecek, Miroslav

    2011-09-01

    Proper identification of the cardiac cycle is essential for gated SPECT myocardial perfusion imaging. We have developed an alternate method of ECG for gating, that is, using the peripheral pulse wave (PW) as the triggering signal for gated SPECT acquisition. The aim of this study is to compare the use of this method of gating with the standard ECG trigger. We tested the PW triggering by comparing it with the ECG trigger. We evaluated 33 patients (25 males, 8 females), average age of 61 years (39-80) referred for stress myocardial perfusion imaging. Data from all patients were acquired twice and were processed by CEqual and QGS software. We compared the left ventricular ejection fraction (LVEF), end-diastolic and end-systolic volumes (EDV, ESV). Paired t test and Pearson correlation coefficient were used for comparison. The mean LVEF, EDV, and ESV calculated with the ECG trigger were 0.52, 120, and 64, respectively, those with the pulse-wave trigger were 0.48, 126, and 71, respectively. Mean paired difference for LVEF was -0.034 (P<0.001), for EDV 5.9 (P=0.012), and for ESV 7.9 (P<0.001). Pearson correlation coefficient for LVEF was 0.955, for EDV 0.987, and for ESV 0.991 (P<0.001 for all correlations). Triggering of gated-data acquisition by the PW is feasible. Quantitative parameters of cardiac function correlate highly with those obtained from the ECG trigger and the absolute differences are not clinically significant across a wide range of values.

  3. The effect of low-dose β-blocker on heart rate and heart rate variability in health subjects wth a resting heart rate of less than 65 beats per minute: Effect on the quality of prospective electrocardiography-gated coronary CT angiography

    International Nuclear Information System (INIS)

    Park, Chul Hwan; Kim, Tae Hoon; Lee, Sang Min; Hong, Yoo Jin

    2015-01-01

    We assessed the effect of a low-dose β-blocker on heart rate (HR), HR variability (HRV) and image quality of prospective electrocardiography-gated coronary CT angiography (CCTA) in healthy subjects with low HR. CCTA was performed with a 64-slice CT in 75 subjects with a HR of less than 65 beats per minute (bpm). Subjects were divided into 2 groups: Group 1 (G1), 35 with a low dose β-blocker; and Group 2 (G2), 40 without pre-medication. The image quality (IQ) of the CCTA was assessed on a 4-point grading scale (1, poor; 4, excellent). Initial HR (bpm) was not different between the 2 groups. HR during CCTA was lower in G1 than G2 (50.3 ± 5.6 vs. 53.3 ± 4.8, p = 0.016). HRV was not different between the 2 groups. Per-segment analysis showed better IQ at the mid-segment of the right coronary artery (3.0 ± 0.9 vs. 2.5 ± 1.1, p = 0.039) and the first diagonal branch (3.4 ± 0.6 vs. 3.1 ± 0.7, p = 0.024), in the G1 than the G2 group, respectively. The IQ was negatively correlated with HR, but no correlation was found between HRV and IQ. The IQs in the per-vessel analysis were not different between the 2 groups. Low-dose β-blocker reduced HR and improved the IQ of CCTA in a few segments, even at a HR of less than 65 bpm. However the effect was limited.

  4. The effect of low-dose β-blocker on heart rate and heart rate variability in health subjects wth a resting heart rate of less than 65 beats per minute: Effect on the quality of prospective electrocardiography-gated coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Hwan; Kim, Tae Hoon [Dept. of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Sang Min [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Hong, Yoo Jin [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-02-15

    We assessed the effect of a low-dose β-blocker on heart rate (HR), HR variability (HRV) and image quality of prospective electrocardiography-gated coronary CT angiography (CCTA) in healthy subjects with low HR. CCTA was performed with a 64-slice CT in 75 subjects with a HR of less than 65 beats per minute (bpm). Subjects were divided into 2 groups: Group 1 (G1), 35 with a low dose β-blocker; and Group 2 (G2), 40 without pre-medication. The image quality (IQ) of the CCTA was assessed on a 4-point grading scale (1, poor; 4, excellent). Initial HR (bpm) was not different between the 2 groups. HR during CCTA was lower in G1 than G2 (50.3 ± 5.6 vs. 53.3 ± 4.8, p = 0.016). HRV was not different between the 2 groups. Per-segment analysis showed better IQ at the mid-segment of the right coronary artery (3.0 ± 0.9 vs. 2.5 ± 1.1, p = 0.039) and the first diagonal branch (3.4 ± 0.6 vs. 3.1 ± 0.7, p = 0.024), in the G1 than the G2 group, respectively. The IQ was negatively correlated with HR, but no correlation was found between HRV and IQ. The IQs in the per-vessel analysis were not different between the 2 groups. Low-dose β-blocker reduced HR and improved the IQ of CCTA in a few segments, even at a HR of less than 65 bpm. However the effect was limited.

  5. Real-Time ECG Simulation for Hybrid Mock Circulatory Loops.

    Science.gov (United States)

    Korn, Leonie; Rüschen, Daniel; Zander, Niklas; Leonhardt, Steffen; Walter, Marian

    2018-02-01

    Classically, mock circulatory loops only simulate mechanical properties of the circulation. To connect the hydraulic world with electrophysiology, we present a real-time electrical activity model of the heart and show how to integrate this model into a real-time mock loop simulation. The model incorporates a predefined conduction pathway and a simplified volume conductor to solve the bidomain equations and the forward problem of electrocardiography, resulting in a physiological simulation of the electrocardiogram (ECG) at arbitrary electrode positions. A complete physiological simulation of the heart's excitation would be too CPU intensive. Thus, in our model, complexity was reduced to allow real-time simulation of ECG-triggered medical systems in vitro; this decreases time and cost in the development process. Conversely, the presented model can still be adapted to various pathologies by locally changing the properties of the heart's conduction pathway. To simulate the ECG, the heart is divided into suitable areas, which are innervated by the hierarchically structured conduction system. To distinguish different cardiac regions, a segmentation of the heart was performed. In these regions, Prim's algorithm was applied to identify the directed minimal spanning trees for conduction orientation. Each node of the tree was assigned to a cardiac action potential generated by its hybrid automaton to represent the heart's conduction system by the spatial distribution of action potentials. To generate the ECG output, the bidomain equations were implemented and a simple model of the volume conductor of the body was used to solve the forward problem of electrocardiography. As a result, the model simulates potentials at arbitrary electrode positions in real-time. To verify the developed real-time ECG model, measurements were made within a hybrid mock circulatory loop, including a simple ECG-triggered ventricular assist device control. The model's potential value is to simulate

  6. Cost comparisons

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    How much does the LHC cost? And how much does this represent in other currencies? Below we present a table showing some comparisons with the cost of other projects. Looking at the figures, you will see that the cost of the LHC can be likened to that of three skyscrapers, or two seasons of Formula 1 racing! One year's budget of a single large F1 team is comparable to the entire materials cost of the ATLAS or CMS experiments.   Please note that all the figures are rounded for ease of reading.    CHF € $   LHC 4.6 billions 3 billions  4 billions   Space Shuttle Endeavour (NASA) 1.9 billion 1.3 billion 1.7 billion   Hubble Space Telescope (cost at launch – NASA/...

  7. Is community-based electrocardiography education feasible in the ...

    African Journals Online (AJOL)

    Carol Olivia Larson

    Accreditation authorities expect medical schools to increase their teaching standards and civic engagement, despite .... cation (in various contexts), and proficiency. ... the outer circle (such as self-confidence, time management and initiative) ...

  8. Electrocardiography and serum potassium before and after hemodialysis sessions

    International Nuclear Information System (INIS)

    Tarif, N.; Al-Wakeel, Jamal Saleh; Sulaimani, F.; Memon, Nawaz Ali; Al-Suwaida, Abdul Kareem; Yamani, H.; Bakhsh, Ahmed Jahangir

    2008-01-01

    This study was undertaken to assess potassium level and electrocardiographic (ECG) changes post hemodialysis and whether fall in potassium level during hemodialysis may potentiate cardiac arrythemia. We studied 21 chronic hemodialysis (HD) patients who had their serum electrolytes measured before and after dialysis session and ECG performed at the same time. The patients included 14 females and 7 males with a mean age of 53.1+-15.6 years and range from 26 to 81 years; 9 (43%) patients were diabetics. All the patients had been on dialysis for a minimum of 6 months each Pre-HD serum potassium levels had no correlation with any ECG parameters except a negative correlation with T wave amplitude r=-0.5, p=0.021. ECG parameters significantly changed post-HD; the T wave amplitude decreased and the R wave amplitude increased. A comparatively higher R wave significantly decreased the T to R wave ratio post dialysis. The QRS duration and QTc interval also increased significantly. The patients with post-HD serum potassium of 3.5 mmol/L had a higher R wave amplitude and a significantly less T to R wave ratio (11.8+-9.7 vs 6.4+-5.1, p=0.045 and 0.4+-0.38 vs 1.0+-0.97, p=0.049, respectively. In patients with serum potassium decrement of >2.0 mmol/L, the T to R wave ratio decreased significantly, 0.32+-0.21 vs 0.85+-0.26, p=0.023; The T wave amplitude decreased more than the rise in R wave. Multiple regression analysis did not reveal any relationship of pre or post HD ECG changes and serum potassium, serum calcium or net change in serum potassium post-HD. We conclude that post-HD serum potassium decrement results in a decrease in T to R wave ratio on ECG; this change may have an arrhythmogenic potential. (author)

  9. Freeware eLearning Flash-ECG for learning electrocardiography.

    Science.gov (United States)

    Romanov, Kalle; Kuusi, Timo

    2009-06-01

    Electrocardiographic (ECG) analysis can be taught in eLearning programmes with suitable software that permits the effective use of basic tools such as a ruler and a magnifier, required for measurements. The Flash-ECG (Research & Development Unit for Medical Education, University of Helsinki, Finland) was developed to enable teachers and students to use scanned and archived ECGs on computer screens and classroom projectors. The software requires only a standard web browser with a Flash plug-in and can be integrated with learning environments (Blackboard/WebCT, Moodle). The Flash-ECG is freeware and is available to medical teachers worldwide.

  10. Biomedical engineering tasks. [electrode development for electrocardiography and electroencephalography

    Science.gov (United States)

    1972-01-01

    Electrocardiographic and vectorcardiographic bioinstrumentation work centered on the development of a new electrode system harness for Project Skylab. Evaluation of several silver electrode configurations proved superior impedance voltage performance for silver/silver chloride electrodes mounted flush by using a paste adhesive. A portable ECG processor has been designed and a breadboard unit has been built to sample ECG input data at a rate of 500 samples per second for arrhythmia detection. A small real time display driver program has been developed for statistical analysis on selected QPS features. Engineering work on a sleep monitoring cap assembly continued.

  11. Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

    Science.gov (United States)

    Spiljak, M.; Petric, A. Domanjko; Wilberg, M.; Olsen, L. H.; Stepancic, A.; Schlegel, T. T.; Starc, V.

    2011-01-01

    Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

  12. Coronary heart disease index based on longitudinal electrocardiography

    Science.gov (United States)

    Townsend, J. C.; Cronin, J. P.

    1977-01-01

    A coronary heart disease index was developed from longitudinal ECG (LCG) tracings to serve as a cardiac health measure in studies of working and, essentially, asymptomatic populations, such as pilots and executives. For a given subject, the index consisted of a composite score based on the presence of LCG aberrations and weighted values previously assigned to them. The index was validated by correlating it with the known presence or absence of CHD as determined by a complete physical examination, including treadmill, resting ECG, and risk factor information. The validating sample consisted of 111 subjects drawn by a stratified-random procedure from 5000 available case histories. The CHD index was found to be significantly more valid as a sole indicator of CHD than the LCG without the use of the index. The index consistently produced higher validity coefficients in identifying CHD than did treadmill testing, resting ECG, or risk factor analysis.

  13. A medical-grade wireless architecture for remote electrocardiography.

    Science.gov (United States)

    Kang, Kyungtae; Park, Kyung-Joon; Song, Jae-Jin; Yoon, Chang-Hwan; Sha, Lui

    2011-03-01

    In telecardiology, electrocardiogram (ECG) signals from a patient are acquired by sensors and transmitted in real time to medical personnel across a wireless network. The use of IEEE 802.11 wireless LANs (WLANs), which are already deployed in many hospitals, can provide ubiquitous connectivity and thus allow cardiology patients greater mobility. However, engineering issues, including the error-prone nature of wireless channels and the unpredictable delay and jitter due to the nondeterministic nature of access to the wireless medium, need to be addressed before telecardiology can be safely realized. We propose a medical-grade WLAN architecture for remote ECG monitoring, which employs the point-coordination function (PCF) for medium access control and Reed-Solomon coding for error control. Realistic simulations with uncompressed two-lead ECG data from the MIT-BIH arrhythmia database demonstrate reliable wireless ECG monitoring; the reliability of ECG transmission exceeds 99.99% with the initial buffering delay of only 2.4 s.

  14. Prognostic value of myocardial perfusion SPECT versus exercise electrocardiography in patients with ST-segment depression on resting electrocardiography.

    Science.gov (United States)

    De Lorenzo, Andrea; Hachamovitch, Rory; Kang, Xingping; Gransar, Heidi; Sciammarella, Maria G; Hayes, Sean W; Friedman, John D; Cohen, Ishac; Germano, Guido; Berman, Daniel S

    2005-01-01

    The value of exercise-induced ST-segment depression for the prognostic evaluation of patients with 1 mm of ST depression or greater on the resting electrocardiogram is controversial. Patients who underwent exercise myocardial perfusion single photon emission computed tomography (MPS) and had resting ST depression of 1 mm or greater with a nondiagnostic exercise electrocardiographic response (n = 1122) were followed up for 3.4 +/- 2.3 years. Those with paced rhythm, pre-excitation, left bundle branch block, or myocardial revascularization within the first 60 days after MPS were excluded. Additional exercise-induced ST-segment depression was considered significant if > or = 2 mm MPS was scored semiquantitatively by use of a 20-segment model of the left ventricle; the percentage of myocardium involved with stress defects (% myo) was derived by normalizing to the maximal possible score of 80. Hard events were defined as nonfatal myocardial infarction or cardiac death. A Cox analysis was used to determine independent predictors of hard events among clinical, exercise, and nuclear variables. Hard event rates increased as a function of % myo for either patients with exercise-induced ST depression (1.4%/y for normal MPS vs 4.1%/y for % myo >10%, P 10%, P = .0001). Age, diabetes mellitus, shortness of breath as the presenting symptom, and % myo were independent predictors of hard events. Exercise-induced ST depression was predictive of hard events only when it was 3 mm or greater. The presence and extent of perfusion defects, reflected in the % myo, had incremental prognostic value over clinical variables and also over all degrees of exercise-induced ST depression. Although MPS effectively risk-stratifies patients with resting ST depression of 1 mm or greater, the prognostic value of exercise-induced ST depression is limited in these patients, with a small added risk when severe (> or = 3 mm).

  15. Eletrocardiografia de cães submetidos a diferentes concentrações de desflurano, pré-tratados ou não com a associação de fentanil/droperidol Electrocardiography of dogs undergoing different desflurane concentrations, premedicated or not with fentanyl/droperidol association

    Directory of Open Access Journals (Sweden)

    Paulo Sérgio Patto dos Santos

    2001-10-01

    Full Text Available Avaliaram-se os efeitos da associação de fentanil e droperidol sobre a freqüência cardíaca (FC e eletrocardiografia (ECG, em cães submetidos à anestesia pelo desflurano. Para tal, foram empregados quarenta animais hígidos, adultos, machos e fêmeas, com peso variando entre 6,5 e 20kg. Os cães foram separados igualmente em dois grupos G1 e G2. Ao G1, administrou-se fentanil (15,7mg/kg associado ao droperidol (0,5mg/kg; ao G2, administrou-se solução fisiológica a 0,9% (placebo, ambos por via intravenosa. Decorridos 15 minutos, induziu-se à anestesia geral com administração intravenosa de propofol (5mg/kg. Ato contínuo, os cães foram submetidos a anestesia inalatória pelo desflurano, diluído em oxigênio, através de circuito anestésico semifechado na concentração inicial de 1,6 CAM. As observações das variáveis tiveram início imediatamente antes da aplicação dos fármacos M1. Novas mensurações foram realizadas 15 minutos após a administração da associação fentanil/droperidol ou placebo M2 e 20 minutos decorridos da indução anestésica M3 (1,6 CAM. As demais colheitas coincidiram com o estabelecimento das concentrações de 1,4; 1,2; e 1,0 CAM, respectivamente M4 a M6. Os dados numéricos destas variáveis foram submetidos à Análise de Perfil, sendo considerado o nível de significância de pThe aim of this work was to evaluate the effects of the fentanil/droperidol association over the heart rate (HR and electrocardiography (ECG of dogs submitted to anesthesia by desflurane. For that, forty healthy adult dogs, males and females were used. The dogs were equally separate in two groups G1 and G2. G1 received fentanil (15.7mg/kg associated to droperidol (0.5mg/kg; while G2 received saline solution at 0.9% (placebo, both applied intravenously. After 15 minutes the general anesthesia was induced with intravenously administration of propofol (5mg/kg. The dogs were submitted to inhalatory anesthesia with desflurane

  16. Comparison is key.

    Science.gov (United States)

    Stone, Mark H; Stenner, A Jackson

    2014-01-01

    Several concepts from Georg Rasch's last papers are discussed. The key one is comparison because Rasch considered the method of comparison fundamental to science. From the role of comparison stems scientific inference made operational by a properly developed frame of reference producing specific objectivity. The exact specifications Rasch outlined for making comparisons are explicated from quotes, and the role of causality derived from making comparisons is also examined. Understanding causality has implications for what can and cannot be produced via Rasch measurement. His simple examples were instructive, but the implications are far reaching upon first establishing the key role of comparison.

  17. The value of endothelium dependent vasodilatation in diagnosing coronary artery disease and its comparison with the results of routine diagnostic tests

    International Nuclear Information System (INIS)

    Ghaffari, S.; Toufan, M.

    2007-01-01

    To determine the predictive value of flow mediated vasodilatation (FMD) compared with angina pectoris, exercise electrocardiography and myocardial perfusion imaging (MPI). This study was carried out in Shahid Madani Heart Center, Tabriz, Iran from April 2004 to September 2006. A total of 92 patients with chest pain syndrome were enrolled in this study. Using high resolution ultrasound system endothelial function was evaluated and the result of the flow-mediated dilation (FMD %) was defined as the percent change in the internal diameter of the brachial artery during reactive hyperemia related to baseline. Coronary artery disease (CAD) was documented in 77 (83.7%) patients. The percentage of FMD was lower in patients with CAD compared with those without it (3.55 +- 3.71 versus 10.76 +- 4.61, p=0.001). In comparison with typical anginal chest pain (sensitivity 46.7%, specificity 80%) exercise stress test (sensitivity 75%, specificity 60%) and MPI (sensitivity 96.5%, specificity 55.6%) the receiver operator characteristic curve showed the percentage FMD optimal cut-off value as <= 7.41 with a sensitivity of 87.0%, specificity of 66.7%, negative predictive value of 93.0% and positive predictive value of 50%. In patients with chest pain syndrome, the FMD is a sensitive indicator of CAD with moderate specificity that is unable to predict accurately the extent and severity of it. (author)

  18. High-Definition Computed Tomography for Coronary Artery Stent Imaging: a Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Wen Jie; Chen, Ke Min; Pang, Li Fang; Zhang, Huang; Pan, Zi Lai [Rui Jin Hospital, Medical School, Shanghai Jiao Tong University, Shangha (China); Guo, Ying; Li, Jian Ying [Beijing Economic and Technology Development Area, Beijing (China)

    2012-01-15

    To assess the performance of a high-definition CT (HDCT) for imaging small caliber coronary stents ({<=} 3 mm) by comparing different scan modes of a conventional 64-row standard-definition CT (SDCT). A cardiac phantom with twelve stents (2.5 mm and 3.0 mm in diameter) was scanned by HDCT and SDCT. The scan modes were retrospective electrocardiography (ECG)-gated helical and prospective ECG-triggered axial with tube voltages of 120 kVp and 100 kVp, respectively. The inner stent diameters (ISD) and the in-stent attenuation value (AVin-stent) and the in-vessel extra-stent attenuation value (AVin-vessel) were measured by two observers. The artificial lumen narrowing (ALN = [ISD - ISDmeasured]/ISD) and artificial attenuation increase between in-stent and in-vessel (AAI = AVin-stent - AVin-vessel) were calculated. All data was analyzed by intraclass correlation and ANOVA-test. The correlation coefficient of ISD, AVin-vessel and AVin-stent between the two observers was good. The ALNs of HDCT were statistically lower than that of SDCT (30 {+-} 5.7% versus 35 {+-} 5.4%, p < 0.05). HDCT had statistically lower AAI values than SDCT (15.7 {+-} 81.4 HU versus 71.4 {+-} 90.5 HU, p < 0.05). The prospective axial dataset demonstrated smaller ALN than the retrospective helical dataset on both HDCT and SDCT (p < 0.05). Additionally, there were no differences in ALN between the 120 kVp and 100 kVp tube voltages on HDCT (p = 0.05). High-definition CT helps improve measurement accuracy for imaging coronary stents compared to SDCT. HDCT with 100 kVp and the prospective ECG-triggered axial technique, with a lower radiation dose than 120 kVp application, may be advantageous in evaluating coronary stents with smaller calibers ({<=} 3 mm).

  19. Dimensional comparison theory.

    Science.gov (United States)

    Möller, Jens; Marsh, Herb W

    2013-07-01

    Although social comparison (Festinger, 1954) and temporal comparison (Albert, 1977) theories are well established, dimensional comparison is a largely neglected yet influential process in self-evaluation. Dimensional comparison entails a single individual comparing his or her ability in a (target) domain with his or her ability in a standard domain (e.g., "How good am I in math compared with English?"). This article reviews empirical findings from introspective, path-analytic, and experimental studies on dimensional comparisons, categorized into 3 groups according to whether they address the "why," "with what," or "with what effect" question. As the corresponding research shows, dimensional comparisons are made in everyday life situations. They impact on domain-specific self-evaluations of abilities in both domains: Dimensional comparisons reduce self-concept in the worse off domain and increase self-concept in the better off domain. The motivational basis for dimensional comparisons, their integration with recent social cognitive approaches, and the interdependence of dimensional, temporal, and social comparisons are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  20. Comparison of long-term clinical outcome between transcatheter Amplatzer occlusion and surgical closure of isolated patent ductus arteriosus.

    Science.gov (United States)

    Chen, Zhao-yang; Wu, Li-ming; Luo, Yu-kun; Lin, Chao-gui; Peng, Ya-fei; Zhen, Xing-chun; Chen, Liang-long

    2009-05-20

    Transcatheter Amplatzer occlusion of patent ductus artertiosus (PDA) has emerged as a minimally invasive alternative to surgical closure. The goal of this study was to compare long-term clinical outcomes between two procedures, especially on chronic residual shunt, late or very late procedure-related complications, and regression of pulmonary hypertension and left ventricular dilation. A total 255 patients having isolated PDA with a minimal diameter of >or= 4 mm treated from January 2000 to July 2003 were included in this study and have been followed up until July 2008. The patients were assigned to either the device or surgical closure group according to the patients' and/or their parents' preference. Baseline physical exams, chest roentgenography, electrocardiography, and echocardiography were performed preprocedure and at each follow-up. Seventy-two patients accepted the transcatheter procedure (Group-TC) and 183 underwent surgical operation (Group-SO) for PDA closure, both groups were similar in their demographics and preoperative clinical characteristics. There were no cardiac deaths and late complications such as infectious endocarditis and Amplatzer duct occluder (ADO) dislodge in either group. More acute procedure-related complications were recorded in Group-SO (13.7%) compared with Group-TC (1.4%) (P = 0.004). The recovery time was (8.7 +/- 2.3) days for the Group-SO and (1.3 +/- 0.5) days for the Group-TC (P ventricular dilation; neither survival freedom from pulmonary hypertension nor abnormal left ventricular end-diastolic volume index were significantly different between the surgical group and the Amplatzer group. Our study confirmed the long-term safety and efficacy of transcatheter Amplatzer occlusion. In comparison to the time-proven surgical closure, transcatheter Amplatzer occlusion was less invasive and associated with fewer complications and residual shunt, and as effective in the regression of pulmonary hypertension and left ventricular

  1. Satisfaction and 'comparison sharing'

    DEFF Research Database (Denmark)

    Amilon, Anna

    2009-01-01

    the probability of satisfaction. Results show that comparison sharing impacts satisfaction for women, and that those women who share more equally than their peers are more likely to be satisfied, whereas comparison sharing has no influence on satisfaction for men. Also, parents are less likely to be satisfied...

  2. Matrix comparison, Part 2

    DEFF Research Database (Denmark)

    Schneider, Jesper Wiborg; Borlund, Pia

    2007-01-01

    The present two-part article introduces matrix comparison as a formal means for evaluation purposes in informetric studies such as cocitation analysis. In the first part, the motivation behind introducing matrix comparison to informetric studies, as well as two important issues influencing such c...

  3. Comparison versus reminding.

    Science.gov (United States)

    Tullis, Jonathan G; Goldstone, Robert L

    2016-01-01

    Comparison and reminding have both been shown to support learning and transfer. Comparison is thought to support transfer because it allows learners to disregard non-matching features of superficially different episodes in order to abstract the essential structure of concepts. Remindings promote memory for the individual episodes and generalization because they prompt learners to retrieve earlier episodes during the encoding of later related episodes and to compare across episodes. Across three experiments, we compared the consequences of comparison and reminding on memory and transfer. Participants studied a sequence of related, but superficially different, proverb pairs. In the comparison condition, participants saw proverb pairs presented together and compared their meaning. In the reminding condition, participants viewed proverbs one at a time and retrieved any prior studied proverb that shared the same deep meaning as the current proverb. Experiment 1 revealed that participants in the reminding condition recalled more proverbs than those in the comparison condition. Experiment 2 showed that the mnemonic benefits of reminding persisted over a one-week retention interval. Finally, in Experiment 3, we examined the ability of participants to generalize their remembered information to new items in a task that required participants to identify unstudied proverbs that shared the same meaning as studied proverbs. Comparison led to worse discrimination between proverbs related to studied proverbs and proverbs unrelated to studied proverbs than reminding. Reminding supported better memory for individual instances and transfer to new situations than comparison.

  4. Statistical Group Comparison

    CERN Document Server

    Liao, Tim Futing

    2011-01-01

    An incomparably useful examination of statistical methods for comparisonThe nature of doing science, be it natural or social, inevitably calls for comparison. Statistical methods are at the heart of such comparison, for they not only help us gain understanding of the world around us but often define how our research is to be carried out. The need to compare between groups is best exemplified by experiments, which have clearly defined statistical methods. However, true experiments are not always possible. What complicates the matter more is a great deal of diversity in factors that are not inde

  5. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    International Nuclear Information System (INIS)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H.

    2009-01-01

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6≤pitch≤3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  6. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

    Science.gov (United States)

    Flohr, Thomas G; Leng, Shuai; Yu, Lifeng; Aiimendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H

    2009-12-01

    To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. No significant differences in quantitative measures of image quality were found between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6 pitch 3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch = 3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom

  7. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Flohr, Thomas G.; Leng Shuai; Yu Lifeng; Allmendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D.; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H. [Siemens Healthcare, Computed Tomography, 91301 Forchheim, Germany and Department of Diagnostic Radiology, Eberhard-Karls-Universitaet, 72076 Tuebingen (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Siemens Healthcare, Computed Tomography, 91301 Forchheim (Germany); Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2009-12-15

    Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving

  8. Public opinion: Country comparisons

    Science.gov (United States)

    Hopkins, Debbie

    2015-11-01

    Climate change awareness, risk perception and policy support vary between and within countries. National-scale comparisons can help to explain this variability and be used to develop targeted interventions.

  9. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  10. CCF model comparison

    International Nuclear Information System (INIS)

    Pulkkinen, U.

    2004-04-01

    The report describes a simple comparison of two CCF-models, the ECLM, and the Beta-model. The objective of the comparison is to identify differences in the results of the models by applying the models in some simple test data cases. The comparison focuses mainly on theoretical aspects of the above mentioned CCF-models. The properties of the model parameter estimates in the data cases is also discussed. The practical aspects in using and estimating CCFmodels in real PSA context (e.g. the data interpretation, properties of computer tools, the model documentation) are not discussed in the report. Similarly, the qualitative CCF-analyses needed in using the models are not discussed in the report. (au)

  11. Comparisons and Lessons Learned

    NARCIS (Netherlands)

    Jensen, PA; van der Voordt, Theo; Coenen, C; Sarasoja, AL; van der Voordt, DJM; Jensen, PA; Coenen, C

    2012-01-01

    Purpose: To create an overview and evaluation of the achievements of the contributions in this book by identifying, summarising and discussing cross-cutting themes and essential learning points across the former chapters.
    Methodology: Based on a purposeful reading of all chapters comparisons are

  12. Motives for Social Comparison.

    Science.gov (United States)

    Helgeson, Vicki S.; Mickelson, Kristin D.

    1995-01-01

    A set of motive statements for social comparison was elicited from one group of subjects and then rated in terms of usefulness by a second group of subjects. Analysis of these statements revealed six motives in response to two different hypothetical scenarios: self-evaluation, common bond, self-improvement, self-enhancement, altruism, and…

  13. MCNP and GADRAS Comparisons

    International Nuclear Information System (INIS)

    Klasky, Marc Louis; Myers, Steven Charles; James, Michael R.; Mayo, Douglas R.

    2016-01-01

    To facilitate the timely execution of System Threat Reviews (STRs) for DNDO, and also to develop a methodology for performing STRs, LANL performed comparisons of several radiation transport codes (MCNP, GADRAS, and Gamma-Designer) that have been previously utilized to compute radiation signatures. While each of these codes has strengths, it is of paramount interest to determine the limitations of each of the respective codes and also to identify the most time efficient means by which to produce computational results, given the large number of parametric cases that are anticipated in performing STR's. These comparisons serve to identify regions of applicability for each code and provide estimates of uncertainty that may be anticipated. Furthermore, while performing these comparisons, examination of the sensitivity of the results to modeling assumptions was also examined. These investigations serve to enable the creation of the LANL methodology for performing STRs. Given the wide variety of radiation test sources, scenarios, and detectors, LANL calculated comparisons of the following parameters: decay data, multiplicity, device (n,γ) leakages, and radiation transport through representative scenes and shielding. This investigation was performed to understand potential limitations utilizing specific codes for different aspects of the STR challenges.

  14. Secure quantum private comparison

    International Nuclear Information System (INIS)

    Yang Yuguang; Cao Weifeng; Wen Qiaoyan

    2009-01-01

    We propose a two-party quantum private comparison protocol using single photons, in which two distrustful parties can compare whether their secrets are equal with the help of a third party (TP). Any information about the values of their respective secrets will not be leaked out even with a compromised TP. Security is also discussed.

  15. Secure quantum private comparison

    Energy Technology Data Exchange (ETDEWEB)

    Yang Yuguang [College of Computer Science and Technology, Beijing University of Technology, Beijing 100124 (China); Cao Weifeng [College of Electric and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002 (China); Wen Qiaoyan [State Key Laboratory of Networking and Switching Technology, Beijing University of Posts and Telecommunications, Beijing 100876 (China)], E-mail: yangyang7357@bjut.edu.cn

    2009-12-15

    We propose a two-party quantum private comparison protocol using single photons, in which two distrustful parties can compare whether their secrets are equal with the help of a third party (TP). Any information about the values of their respective secrets will not be leaked out even with a compromised TP. Security is also discussed.

  16. Use of comparison cases

    Energy Technology Data Exchange (ETDEWEB)

    Klein, G.A.

    1982-01-01

    How can we make predictions about complex ill-defined domains. expert judgement does not tell us about the basis for the prediction. Formal analysis, on the other hand, is expensive to implement and may not be feasible if there are unknown parameters. The use of comparison cases offers a middle ground between these two extremes. In order to apply comparison-based predictions, we must understand the logic governing its use. It is argued that the use of comparision cases in analogical reasoning is a form of deductive rather than probabilistic inference, and under certain conditions can yield valid conclusions. For most applications, the necessary conditions for ensuring validity will not be met, but actions can be taken to increase confidence in the prediction. 4 references.

  17. Problems of comparison

    International Nuclear Information System (INIS)

    Horn, G.

    1989-01-01

    This paper reports on determination of the balance of forces embrace a much wider area than the scope of mere numerical comparisons. In Europe that there is rough parity between the conventional forces of WTO and NATO, we do not claim that both sides have the same forces. The balance of forces cannot be considered except in view of purpose and circumstances. In our case, the balance of forces in Europe can be taken to mean that neither side has enough strength to impose its will on the other by military force. Of course, this type of comparison cannot be used at the disarmament talks to take stock of armed forces and to determine the final result of reductions, or of the reduction process. Nevertheless it is very important to know that the talks will be conducted against the background and that the final result should not, in this one respect, be any different from the point of departure

  18. Comparison of societal risks

    International Nuclear Information System (INIS)

    Bennett, C.A.

    1976-01-01

    The utility of the societal risk approach to the design and evaluation of safeguards systems is examined with particular reference to the comparison of the relative effectiveness of various safeguards mechanisms. Research on threat evaluation is reviewed, and the need for further research on consequences is discussed in terms of the extension of the definition of the safeguards objective from system capability to societal consequences and the establishment of public confidence. 14 references

  19. Robust forecast comparison

    OpenAIRE

    Jin, Sainan; Corradi, Valentina; Swanson, Norman

    2015-01-01

    Forecast accuracy is typically measured in terms of a given loss function. However, as a consequence of the use of misspecified models in multiple model comparisons, relative forecast rankings are loss function dependent. This paper addresses this issue by using a novel criterion for forecast evaluation which is based on the entire distribution of forecast errors. We introduce the concepts of general-loss (GL) forecast superiority and convex-loss (CL) forecast superiority, and we establish a ...

  20. Retained gas inventory comparison

    International Nuclear Information System (INIS)

    BARTON, W.B.

    1999-01-01

    Gas volume data derived from four different analytical methods were collected and analyzed for comparison to volumes originally used in the technical basis for the Basis for Interim Operations (BIO). The original volumes came from Hodgson (1996) listed in the reference section of this document. Hodgson (1996) screened all 177 single and double-shell tanks for the presence of trapped gas in waste via two analytical methods: Surface Level Rise (SLR), and Barometric Pressure Effect (BPE). More recent gas volume projections have been calculated using different analytical techniques along with updates to the parameters used as input to the SLR and BPE models. Gas volumes derived from new analytical instruments include those as measured by the Void Fraction Instrument (VFI) and Retained Gas Sampler (RGS). The results of this comparison demonstrate that the original retained gas volumes of Hodgson (1996) used as a technical basis in developing the BIO were conservative, and were conservative from a safety analysis standpoint. These results represent only comparisons to the original reported volumes using the limited set of newly acquired data that is available

  1. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  2. Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT—Initial experience

    International Nuclear Information System (INIS)

    Takx, Richard A.P.; Schoepf, U. Joseph; Moscariello, Antonio; Das, Marco; Rowe, Garrett; Schoenberg, Stefan O.; Fink, Christian; Henzler, Thomas

    2013-01-01

    Objective: To prospectively compare subjective and objective image quality in 20% tube current coronary CT angiography (cCTA) datasets between an iterative reconstruction algorithm (SAFIRE) and traditional filtered back projection (FBP). Materials and methods: Twenty patients underwent a prospectively ECG-triggered dual-step cCTA protocol using 2nd generation dual-source CT (DSCT). CT raw data was reconstructed using standard FBP at full-dose (Group 1 a) and 80% tube current reduced low-dose (Group 1 b). The low-dose raw data was additionally reconstructed using iterative raw data reconstruction (Group 2 ). Attenuation and image noise were measured in three regions of interest and signal-to-noise-ratio (SNR) as well as contrast-to-noise-ratio (CNR) was calculated. Subjective diagnostic image quality was evaluated using a 4-point Likert scale. Results: Mean image noise of group 2 was lowered by 22% on average when compared to group 1 b (p 2 compared to group 1 b (p 2 (1.88 ± 0.63) was also rated significantly higher when compared to group 1 b (1.58 ± 0.63, p = 0.004). Conclusions: Image quality of 80% tube current reduced iteratively reconstructed cCTA raw data is significantly improved when compared to standard FBP and consequently may improve the diagnostic accuracy of cCTA

  3. NTP comparison process

    Science.gov (United States)

    Corban, Robert

    The systems engineering process for the concept definition phase of the program involves requirements definition, system definition, and consistent concept definition. The requirements definition process involves obtaining a complete understanding of the system requirements based on customer needs, mission scenarios, and nuclear thermal propulsion (NTP) operating characteristics. A system functional analysis is performed to provide a comprehensive traceability and verification of top-level requirements down to detailed system specifications and provides significant insight into the measures of system effectiveness to be utilized in system evaluation. The second key element in the process is the definition of system concepts to meet the requirements. This part of the process involves engine system and reactor contractor teams to develop alternative NTP system concepts that can be evaluated against specific attributes, as well as a reference configuration against which to compare system benefits and merits. Quality function deployment (QFD), as an excellent tool within Total Quality Management (TQM) techniques, can provide the required structure and provide a link to the voice of the customer in establishing critical system qualities and their relationships. The third element of the process is the consistent performance comparison. The comparison process involves validating developed concept data and quantifying system merits through analysis, computer modeling, simulation, and rapid prototyping of the proposed high risk NTP subsystems. The maximum amount possible of quantitative data will be developed and/or validated to be utilized in the QFD evaluation matrix. If upon evaluation of a new concept or its associated subsystems determine to have substantial merit, those features will be incorporated into the reference configuration for subsequent system definition and comparison efforts.

  4. Comparison of imagine systems

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, F. [Hong Kong Polytechnic University, Kowloon (Hong Kong). Optometry and Radiography Department

    1997-12-01

    It is of great use to be able to accurately compare different film/screen systems. It allows informed decisions to be made as to the optimal choice of film and screens in regard to technical matters such as speed and resolution. Comparisons of these have not been easy, especially in the face of different terminology and specifications used by different manufacturers. A straight forward method is proposed, which requires only a line pair test tool, and the ability to produce scattergraphs. The relative efficiencies of different film/screen systems, incorporating orthochromatic and monochromatic elements are clearly portrayed. Copyright (1997) Australian Institute of Radiography 12 refs., 1 tab., 4 figs.

  5. Comparison of imagine systems

    International Nuclear Information System (INIS)

    Mitchell, F.

    1997-01-01

    It is of great use to be able to accurately compare different film/screen systems. It allows informed decisions to be made as to the optimal choice of film and screens in regard to technical matters such as speed and resolution. Comparisons of these have not been easy, especially in the face of different terminology and specifications used by different manufacturers. A straight forward method is proposed, which requires only a line pair test tool, and the ability to produce scattergraphs. The relative efficiencies of different film/screen systems, incorporating orthochromatic and monochromatic elements are clearly portrayed. Copyright (1997) Australian Institute of Radiography

  6. Brain networks of social comparison.

    Science.gov (United States)

    Kedia, Gayannée; Lindner, Michael; Mussweiler, Thomas; Ihssen, Niklas; Linden, David E J

    2013-03-27

    Social comparison, that is, the process of comparing oneself to other people, is a ubiquitous social cognitive mechanism; however, so far its neural correlates have remained unknown. The present study tested the hypothesis that social comparisons are supported by partly dissociated networks, depending on whether the dimension under comparison concerns a physical or a psychological attribute. We measured brain activity with functional MRI, whereas participants were comparing their own height or intelligence to that of individuals they personally know. Height comparisons were associated with higher activity in a frontoparietal network involved in spatial and numerical cognition. Conversely, intelligence comparisons recruited a network of midline areas that have been previously implicated in the attribution of mental states to oneself and others (Theory of mind). These findings suggest that social comparisons rely on diverse domain-specific mechanisms rather than on one unitary process.

  7. Comparison of Hemodynamic Effects and Negative Predictive Value of Normal Adenosine Gated Myocardial Perfusion Scan With or Without Caffeine Abstinence

    International Nuclear Information System (INIS)

    Zaman, Maseeh uz; Fatima, Nosheen; Zaman, Areeba; Zaman, Unaiza; Tahseen, Rabia

    2016-01-01

    For vasodilator stress, myocardial perfusion imaging (MPI) with at least 12-h caffeine abstinence is recommended, as it attenuates cardiovascular hyperemic response of adenosine and dipyridamole. However, many published conflicting results have shown no significant effect upon perfusion abnormalities in MPI performed without caffeine abstinence. The aim of this study was to compare the hemodynamic changes and negative predictive value (NPV) of normal MPIs with adenosine stress performed with or without caffeine abstinence. This was a prospective study that accrued 50 patients from May 2013 till September 2013 and followed till November 2014. These patients had a normal adenosine-gated MPI (GMPI) with technetium-99m methoxy isobutyl isonitrile ( 99m Tc-MIBI) after 12-h caffeine abstinence (no-caffeine). Next day, all patients had a repeat adenosine stress within 60 min after ingestion of a cup of coffee (about 80 mg of caffeine) followed by no MPI in 30 patients due to concern about radiation dose (prior-caffeine adenosine—no MPI; group A). Twenty patients opted for a repeat MPI (prior-caffeine adenosine—MPI; group B). Adenosine-induced hemodynamic response and NPV of the normal MPI with no-caffeine and prior-caffeine protocols were compared. The mean age of the study cohort was 57 ± 9 years with a male-to-female ratio of 76:24% and mean body mass index (BMI) of 26.915 ± 4.121 kg/m 2 . Prevalence of hypertension, diabetes, dyslipidemia, and positive family history were 76%, 20%, 22%, and 17%, respectively. Comparison of group A with group B revealed no significant difference in demographic parameters, hemodynamic or electrocardiography (ECG) parameters, or left ventricular (LV) function parameters during adenosine intervention with prior-caffeine and no-caffeine protocols. During the follow-up, no fatal myocardial infarction (MI) was reported but 6 nonfatal MIs were reported based upon the history of short hospitalization for chest pain but without biochemical

  8. PSF interlaboratory comparison

    International Nuclear Information System (INIS)

    Kellogg, L.S.; Lippincott, E.P.

    1982-01-01

    Two experiments for interlaboratory verification of radiometric analysis methods have been conducted with dosimeters irradiated in the Oak Ridge Research Reactor (ORR) Poolside Facility (PSF) Surveillance Dosimeter Measurement Facility (SDMF). In a preliminary analysis of data supplied by the six participants, biases as large as 60% were observed which could lead to errors of this general magnitude in reported surveillance capsule fluence values. As a result of these comparisons, problems were identified and the spread in final values was greatly reduced. Relative agreement among the final results reported by four of the laboratories now appears to be satisfactory (the non-fission dosimeter results generally falling within +-5% and the fission dosimeter results within +-10%), but improvement is required in order to routinely meet Reactor Vessel Material Surveillance Program goals

  9. Interlaboratory niobium dosimetry comparison

    International Nuclear Information System (INIS)

    Wille, P.

    1980-01-01

    For an interlaboratory comparison of neutron dosimetry using niobium the 93 sup(m)Nb activities of irradiated niobium monitors were measured. This work was performed to compare the applied techniques of dosimetry with Nb in different laboratories. The niobium monitors were irradiated in the fast breeder EBRII, USA and the BR2, Belgium. The monitors were dissolved and several samples were prepared. Their niobium contents were determined by the 94 Nb-count rates. since the original specific count rate was known. The KX radiations of the 93 sup(m)Nb of the samples and of a calibrated Nb-foil were compared. This foil was measured by PTB, Braunschweig and CBNM, Geel, which we additionally compared with the KX radiation of 88 Sr produced by a thin 88 Y source from a 88 Y-standard solution (PTB). (orig.) [de

  10. Glovebox decontamination technology comparison

    International Nuclear Information System (INIS)

    Quintana, D.M.; Rodriguez, J.B.; Cournoyer, M.E.

    1999-01-01

    Reconfiguration of the CMR Building and TA-55 Plutonium Facility for mission requirements will require the disposal or recycle of 200--300 gloveboxes or open front hoods. These gloveboxes and open front hoods must be decontaminated to meet discharge limits for Low Level Waste. Gloveboxes and open front hoods at CMR have been painted. One of the deliverables on this project is to identify the best method for stripping the paint from large numbers of gloveboxes. Four methods being considered are the following: conventional paint stripping, dry ice pellets, strippable coatings, and high pressure water technology. The advantages of each technology will be discussed. Last, cost comparisons between the technologies will be presented

  11. Improving the DGK comparison protocol

    NARCIS (Netherlands)

    Veugen, P.J.M.

    2012-01-01

    When processing signals in the encrypted domain, homomorphic encryption can be used to enable linear operations on encrypted data. Comparison of encrypted data however requires an additional protocol between the parties and will be relatively expensive. A well-known and frequently used comparison

  12. EUROMET SUPPLEMENTARY COMPARISON - SURFACE TEXTURE

    DEFF Research Database (Denmark)

    Koenders, L.; Andreasen, Jan Lasson; De Chiffre, Leonardo

    At the length meeting in Prague in Oct. 1999 a new comparison was suggested on surface texture. The last comparison on this field was finished in 1989. In the meantime the instrumentation, the standards and the written standards have been improved including some software filters. The pilot labora...

  13. NTF – wind speed comparison

    DEFF Research Database (Denmark)

    Vesth, Allan; Gómez Arranz, Paula

    The report describes measurements carried out on a given turbine. A comparison between wind speed on the met mast and Nacelle Wind speed are made and the results are presented on graphs and in a table. The data used for the comparison are the data that are same as used for the power curve report...

  14. Social Comparison in the Classroom: A Review

    Science.gov (United States)

    Dijkstra, Pieternel; Kuyper, Hans; van der Werf, Greetje; Buunk, Abraham P.; van der Zee, Yvonne G.

    2008-01-01

    This article reviews research conducted on social comparison processes in the classroom since Festinger proposed his theory of social comparison. It covers the theoretical framework of social comparison theory, and it is organized around the following themes: motives for social comparison, dimensions of social comparison, direction of social…

  15. Comparisons of mental clocks.

    Science.gov (United States)

    Paivio, A

    1978-02-01

    Subjects in three experiments were presented with pairs of clock times and were required to choose the one in which the hour and minute hand formed the smaller angle. In Experiments 1 and 2, the times were presented digitally, necessitating a transformation into symbolic representations from which the angular size difference could be inferred. The results revealed orderly symbolic distance effects so that comparison reaction time increased as the angular size difference decreased. Moreover, subjects generally reported using imagery to make the judgment, and subjects scoring high on test of imagery ability were faster than those scoring low on such tests. Experiment 3 added a direct perceptual condition in which subjects compared angles between pairs of hands on two drawn (analog) clocks, as well as a mixed condition involving one digital and one analog clock time. The results showed comparable distance effects for all conditions. In addition, reaction time increased from the perceptual, to the mixed, to the pure-digital condition. These results are consistent with predictions from an image-based dual-coding theory.

  16. [Anemia: guidelines comparison].

    Science.gov (United States)

    Del Vecchio, Lucia

    2009-01-01

    The development of recombinant human erythropoietin and its introduction into the market in the late 1980s has significantly improved the quality of life of patients with chronic kidney disease (CKD) and reduced the need for blood transfusions. Starting from a cautious target, a progressive increase in the recommended hemoglobin levels has been observed over the years, in parallel with an increase in the obtained levels. This trend has gone together with the publication of findings of observational studies showing a relationship between the increase in hemoglobin levels and a reduction in the mortality risk, with the conduction of clinical trials testing the effects of complete anemia correction, and with the compilation of guidelines on anemia control in CKD patients by scientific societies and organizations. In the last two years, evidence of a possible increase in the mortality risk in those patients who were randomized to high hemoglobin levels has resulted in a decrease in the upper limit of the recommended Hb target to be obtained with erythropoietin stimulating agents (ESA), and consequently in a narrowing of the target range. Comparison of guidelines on anemia control in CKD patients is an interesting starting point to discuss single recommendations, strengthen their importance, or suggest new topics of research to fill up important gaps in knowledge.

  17. Homomorphic encryption and secure comparison

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Geisler, Martin; Krøigaard, Mikkel

    2008-01-01

    Computation (MPC). We show how our comparison protocol can be used to improve security of online auctions, and demonstrate that it is efficient enough to be used in practice. For comparison of 16 bits numbers with security based on 1024 bits RSA (executed by two parties), our implementation takes 0.28 sec......We propose a protocol for secure comparison of integers based on homomorphic encryption.We also propose a homomorphic encryption scheme that can be used in our protocol, makes it more efficient than previous solutions, and can also be used as the basis of efficient and general secure Multiparty...

  18. A segmented K-space velocity mapping protocol for quantification of renal artery blood flow during breath-holding

    DEFF Research Database (Denmark)

    Thomsen, C; Cortsen, M; Söndergaard, L

    1995-01-01

    for renal artery flow determination. The protocol uses 16 phase-encoding lines per heart beat during 16 heart cycles and gives a temporal velocity resolution of 160 msec. Comparison with a conventional ECG-triggered velocity mapping protocol was made in phantoms as well as in volunteers. In our study, both...... methods showed sufficient robustness toward complex flow in a phantom model. In comparison with the ECG technique, the segmentation technique reduced vessel blurring and pulsatility artifacts caused by respiratory motion, and average flow values obtained in vivo in the left renal artery agreed between......Two important prerequisites for MR velocity mapping of pulsatile motion are synchronization of the sequence execution to the time course of the flow pattern and robustness toward loss of signal in complex flow fields. Synchronization is normally accomplished by using either prospective ECG...

  19. Radiological risk comparison guidelines

    International Nuclear Information System (INIS)

    Hallinan, E.J.; Muhlestein, L.D.; Brown, L.F.; Yoder, R.E.

    1992-01-01

    An important aspect of DOE safety analyses is estimating potential accident risk. The estimates are used to: determine if additional controls are needed, identify Safety Class Items, and demonstrate adequate risk reduction. Thus, guidelines are needed to measure comparative risks. The Westinghouse M ampersand O Nuclear Facility Safety Committee and the Safety Envelope Working Group have developed radiological risk guidelines for comparing the risks from individual accident analyses. These guidelines were prepared under contract with the US Department of Energy. These guidelines are based on historical DOE guidelines and current requirements, and satisfy DOE and technical community proposals. for goals that demonstrate acceptable risk. The guidelines consist of a frequency versus consequence curve for credible accidents. Offsite and onsite guidelines are presented. The offsite risk acceptance guidelines are presented in Figure 1. The guidelines are nearly isorisk for anticipated events where impacts are chronic, and provide additional reduction for unlikely events where impacts may be acute and risk uncertainties may be significant. The guidelines are applied to individual release accident scenarios where a discrete frequency and consequence has been estimated. The guideline curves are not to be used for total risk assessments. Common cause events are taken into consideration only for an individual facility. Frequencies outside the guideline range are considered to be local site option (analyst judgement) as far as assessments of risk acceptance are concerned. If the curve is exceeded, then options include either a more detailed analysis or imposing additional preventive or mitigative features. Another presentation discusses implementation in detail. Additional work is needed to provide risk comparison guidelines for releases from multiple facilities and for toxic releases

  20. Visual comparison for information visualization

    KAUST Repository

    Gleicher, M.; Albers, D.; Walker, R.; Jusufi, I.; Hansen, C. D.; Roberts, J. C.

    2011-01-01

    Data analysis often involves the comparison of complex objects. With the ever increasing amounts and complexity of data, the demand for systems to help with these comparisons is also growing. Increasingly, information visualization tools support such comparisons explicitly, beyond simply allowing a viewer to examine each object individually. In this paper, we argue that the design of information visualizations of complex objects can, and should, be studied in general, that is independently of what those objects are. As a first step in developing this general understanding of comparison, we propose a general taxonomy of visual designs for comparison that groups designs into three basic categories, which can be combined. To clarify the taxonomy and validate its completeness, we provide a survey of work in information visualization related to comparison. Although we find a great diversity of systems and approaches, we see that all designs are assembled from the building blocks of juxtaposition, superposition and explicit encodings. This initial exploration shows the power of our model, and suggests future challenges in developing a general understanding of comparative visualization and facilitating the development of more comparative visualization tools. © The Author(s) 2011.

  1. Visual comparison for information visualization

    KAUST Repository

    Gleicher, M.

    2011-09-07

    Data analysis often involves the comparison of complex objects. With the ever increasing amounts and complexity of data, the demand for systems to help with these comparisons is also growing. Increasingly, information visualization tools support such comparisons explicitly, beyond simply allowing a viewer to examine each object individually. In this paper, we argue that the design of information visualizations of complex objects can, and should, be studied in general, that is independently of what those objects are. As a first step in developing this general understanding of comparison, we propose a general taxonomy of visual designs for comparison that groups designs into three basic categories, which can be combined. To clarify the taxonomy and validate its completeness, we provide a survey of work in information visualization related to comparison. Although we find a great diversity of systems and approaches, we see that all designs are assembled from the building blocks of juxtaposition, superposition and explicit encodings. This initial exploration shows the power of our model, and suggests future challenges in developing a general understanding of comparative visualization and facilitating the development of more comparative visualization tools. © The Author(s) 2011.

  2. The value of electrocardiography for differential diagnosis in wide QRS complex tachycardia.

    Science.gov (United States)

    Sousa, Pedro A; Pereira, Salomé; Candeias, Rui; de Jesus, Ilídio

    2014-03-01

    Correct diagnosis in wide QRS complex tachycardia remains a challenge. Differential diagnosis between ventricular and supraventricular tachycardia has important therapeutic and prognostic implications, and although data from clinical history and physical examination may suggest a particular origin, it is the 12-lead surface electrocardiogram that usually enables this differentiation. Since 1978, various electrocardiographic criteria have been proposed for the differential diagnosis of wide complex tachycardias, particularly the presence of atrioventricular dissociation, and the axis, duration and morphology of QRS complexes. Despite the wide variety of criteria, diagnosis is still often difficult, and errors can have serious consequences. To reduce such errors, several differential diagnosis algorithms have been proposed since 1991. However, in a small percentage of wide QRS tachycardias the diagnosis remains uncertain and in these the wisest decision is to treat them as ventricular tachycardias. The authors' objective was to review the main electrocardiographic criteria and differential diagnosis algorithms of wide QRS tachycardia. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  3. Electrocardiography in Noonan syndrome PTPN11 gene mutation--phenotype characterization.

    NARCIS (Netherlands)

    Croonen, E.A.; Burgt, I. van der; Kapusta, L.; Draaisma, J.M.T.

    2008-01-01

    Noonan syndrome is a developmental disorder with distinctive facial features, short stature and cardiac abnormalities. In this cross-sectional study, we evaluated characteristic electrocardiographic (ECG) findings and cardiac abnormalities in 84 patients with Noonan syndrome, 56 (67%) of who were

  4. Maximal exercise electrocardiography responses and coronary heart disease mortality among men with diabetes mellitus.

    Science.gov (United States)

    Lyerly, G William; Sui, Xuemei; Church, Timothy S; Lavie, Carl J; Hand, Gregory A; Blair, Steven N

    2008-05-27

    An abnormal ECG during maximal exercise testing has been shown to be a powerful predictor of future coronary heart disease (CHD) mortality in asymptomatic men. However, little is known about the relationship between exercise ECG responses and CHD risk in men with diabetes mellitus. We examined the association between exercise ECG responses and mortality in 2854 men with documented diabetes mellitus (mean age 49.5 years) who completed a maximal treadmill exercise test during the period from 1974 to 2001 and who were without a previous cardiovascular disease (CVD) event at baseline. Mortality due to all causes, CHD, and CVD were the main outcome measures across categories of exercise ECG responses, with stratification by cardiorespiratory fitness, quantified as treadmill test duration. During an average follow-up of 16 years, 441 deaths (210 CVD and 133 CHD) were identified. Across normal, equivocal, and abnormal exercise ECG groups, age- and examination year-adjusted CHD mortality rates per 10 000 person-years were 23.0, 48.6, and 69.0, respectively (P(trend)<0.001). After further adjustment for fasting plasma glucose level, smoking, body mass index, hypercholesterolemia, hypertension, family history of CVD or diabetes mellitus, abnormal resting ECG responses, and cardiorespiratory fitness, hazard ratios (95% confidence intervals) were 1.00 (referent), 1.68 (1.01 to 2.77), and 2.21 (1.41 to 3.46; P(trend)<0.001). Similar patterns of associations were noted between exercise ECG testing and both CVD and all-cause mortality risk. Among men with diabetes mellitus, equivocal and abnormal exercise ECG responses were associated with higher risk of all-cause, CVD, and CHD mortality.

  5. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring

    OpenAIRE

    Amale Ankhili; Xuyuan Tao; Cédric Cochrane; David Coulon; Vladan Koncar

    2018-01-01

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The ...

  6. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Amale Ankhili

    2018-02-01

    Full Text Available A medical quality electrocardiogram (ECG signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene:poly(styrenesulfonate (PEDOT:PSS in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras, by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  7. Washable and Reliable Textile Electrodes Embedded into Underwear Fabric for Electrocardiography (ECG) Monitoring.

    Science.gov (United States)

    Ankhili, Amale; Tao, Xuyuan; Cochrane, Cédric; Coulon, David; Koncar, Vladan

    2018-02-07

    A medical quality electrocardiogram (ECG) signal is necessary for permanent monitoring, and an accurate heart examination can be obtained from instrumented underwear only if it is equipped with high-quality, flexible, textile-based electrodes guaranteeing low contact resistance with the skin. The main objective of this article is to develop reliable and washable ECG monitoring underwear able to record and wirelessly send an ECG signal in real time to a smart phone and further to a cloud. The article focuses on textile electrode design and production guaranteeing optimal contact impedance. Therefore, different types of textile fabrics were coated with modified poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) in order to develop and manufacture reliable and washable textile electrodes assembled to female underwear (bras), by sewing using commercially available conductive yarns. Washability tests of connected underwear containing textile electrodes and conductive threads were carried out up to 50 washing cycles. The influence of standardized washing cycles on the quality of ECG signals and the electrical properties of the textile electrodes were investigated and characterized.

  8. Wavelet-sparsity based regularization over time in the inverse problem of electrocardiography.

    Science.gov (United States)

    Cluitmans, Matthijs J M; Karel, Joël M H; Bonizzi, Pietro; Volders, Paul G A; Westra, Ronald L; Peeters, Ralf L M

    2013-01-01

    Noninvasive, detailed assessment of electrical cardiac activity at the level of the heart surface has the potential to revolutionize diagnostics and therapy of cardiac pathologies. Due to the requirement of noninvasiveness, body-surface potentials are measured and have to be projected back to the heart surface, yielding an ill-posed inverse problem. Ill-posedness ensures that there are non-unique solutions to this problem, resulting in a problem of choice. In the current paper, it is proposed to restrict this choice by requiring that the time series of reconstructed heart-surface potentials is sparse in the wavelet domain. A local search technique is introduced that pursues a sparse solution, using an orthogonal wavelet transform. Epicardial potentials reconstructed from this method are compared to those from existing methods, and validated with actual intracardiac recordings. The new technique improves the reconstructions in terms of smoothness and recovers physiologically meaningful details. Additionally, reconstruction of activation timing seems to be improved when pursuing sparsity of the reconstructed signals in the wavelet domain.

  9. Properties of screen printed electrocardiography smartware electrodes investigated in an electro-chemical cell.

    Science.gov (United States)

    Rattfält, Linda; Björefors, Fredrik; Nilsson, David; Wang, Xin; Norberg, Petronella; Ask, Per

    2013-07-05

    ECG (Electrocardiogram) measurements in home health care demands new sensor solutions. In this study, six different configurations of screen printed conductive ink electrodes have been evaluated with respect to electrode potential variations and electrode impedance. The electrode surfaces consisted of a Ag/AgCl-based ink with a conduction line of carbon or Ag-based ink underneath. On top, a lacquer layer was used to define the electrode area and to cover the conduction lines. Measurements were performed under well-defined electro-chemical conditions in a physiologic saline solution. The results showed that all printed electrodes were stable and have a very small potential drift (less than 3 mV/30 min). The contribution to the total impedance was 2% of the set maximal allowed impedance (maximally 1 kΩ at 50 Hz), assuming common values of input impedance and common mode rejection ratio of a regular amplifier. Our conclusions are that the tested electrodes show satisfying properties to be used as elements in a skin electrode design that could be suitable for further investigations by applying the electrodes on the skin.

  10. Preliminary reference values for electrocardiography, echocardiography and myocardial morphometry in the European brown hare (Lepus europaeus

    Directory of Open Access Journals (Sweden)

    Slawuta Piotr

    2009-01-01

    Full Text Available Abstract The study aimed at defining reference values for electrocardiographic (ECG and echocardiographic parameters as well as macroscopic dimensions of the heart and microscopic dimensions of cardiomyocytes in the European brown hare. The studies were conducted on 30 adult, clinically healthy hares of either sex caught in Poland. ECG and echocardiography were performed supravitally on anaesthetized hares. After euthanasia, gross and microscopic myocardial and cardiomyocyte dimensions were determined. Heart rate amounted to 140 ± 37.5 beats/min, the leading rhythm involved the sinus rhythm. P wave time was 26 ± 5 ms, PQ time was 80 ms, QRS time was 29 ± 3.5 ms, and ST was 97.5 ± 7 ms. Echocardiography determined a left ventricular wall end-diastolic diameter of 8.6 ± 2.0 mm and an intraventricular septum end-diastolic diameter of 5.75 ± 1.0 mm. The thickness of the interventricular septum corresponded to that of the free wall of the left ventricle, a finding consistent with physiological hypertrophy. Preliminary reference values were established for echocardiography. The findings were similar to those obtained at necropsy. The ECG and echocardiographic studies represent the first supravital examination of cardiac function in the hare. The obtained results illustrate adaptation of hare's myocardium to its mode of life. The cardiac findings resemble the athlete's heart syndrome described in humans. The findings may prove useful in further studies on the physiology of the cardio-vascular system in the hare.

  11. Differentiating fasciculoventricular pathway from Wolff-Parkinson-White syndrome by electrocardiography.

    Science.gov (United States)

    Suzuki, Tsugutoshi; Nakamura, Yoshihide; Yoshida, Shuichiro; Yoshida, Yoko; Shintaku, Haruo

    2014-04-01

    In school-based cardiovascular screening programs in Japan, Wolff-Parkinson-White (WPW) syndrome is diagnosed based on the presence of an electrocardiographic (ECG) delta wave without differentiation from the fasciculoventricular pathway (FVP), although the risk of sudden death is associated only with the former. The purpose of this study was to differentiate FVP patients among children diagnosed with WPW syndrome by ECG. Children who were diagnosed with WPW syndrome through school screening between April 2006 and March 2008 and had QRS width ≤120 ms were included. Patients with asthma and/or coronary heart disease were excluded. FVP and WPW syndrome were differentiated based on ECG responses to adenosine triphosphate (ATP) injection. Age, PR interval, QRS width, and Rosenbaum classification were compared among patients. Thirty patients (median age 12.7 years, range 6.5-15.7 years) participated in the study. FVP was diagnosed in 23 patients (76.7%), and WPW syndrome in 7 (23.3%). In Rosenbaum type A patients, all six patients had WPW syndrome, whereas FVP was diagnosed in 23 of 24 and WPW syndrome was diagnosed in 1 of 24 of type B patients. Age, PR interval, and QRS width were not significantly different between the two conditions. ATP stress test was reliable in differentiating FVP from WPW syndrome. Although FVP is considered rare, the results of our study indicate that many WPW syndrome patients with QRS width ≤120 ms may actually have FVP. Patients categorized as type B are more likely to have FVP, whereas type A patients are most likely to have WPW syndrome. © 2013 Heart Rhythm Society Published by Heart Rhythm Society All rights reserved.

  12. Accuracy of localization of acute myocardial infarction by 12 lead electrocardiography

    International Nuclear Information System (INIS)

    Yasuda, T.; Ribeiro, L.G.; Holman, B.L.; Alpert, J.S.; Maroko, P.R.

    1982-01-01

    Until recently, ECG accuracy in localizing acute myocardial infarction (AMI) could be assessed only by comparing the ECGs with autopsy findings. This approach, however, preselected patients, including only those who died. It is possible that this postmortem group of patients would be different from the whole population of patients with AMI. Myocardial imaging with 99 mTc-pyrophosphate offers the advantage of directly localizing the region of injured myocardium in the acute phase of AMI. In 34 patients with confirmed AMI and focal uptake of 99 mTc-pyrophosphate, serial ECGs were obtained and interpreted by two independent observers. The sensitivity and specificity of serial ECGs in determining the location of AMI in the five left ventricular (LV) wall segments were determined: (1) in the anterior wall sensitivity was 86.7% and specificity was 89.5%; (2) in the lateral wall sensitivity was 73.7% and specificity was 80.0%; (3) in the high lateral wall sensitivity was 80.0% and specificity was 87.5%; (4) in the inferior wall sensitivity was 87.5% and specificity was 100%; (5) in the true posterior wall sensitivity was 83.3% and specificity was 86.4%. Overall, in the 170 LV wall segments (five per patient) examined, scans localized with a sensitivity of 81.9% and a specificity of 88.8%. After four patients with LBBB were excluded, sensitivity increased to 87.1%. Overall, localization of AMI by serial ECG was accurate in 85.9% of the 34 patients included in the study

  13. Factors associated with diagnostic discrepancy for left ventricular hypertrophy between electrocardiography and echocardiography

    DEFF Research Database (Denmark)

    Sandager Petersen, Søren; Reinholdt Pedersen, Line; Pareek, Manan

    2017-01-01

    (absolute value/cut-off value for LVH) were used as outcome variables in order to identify explanatory variables associated with diagnostic discrepancies between ECG and echocardiography. RESULTS: Of the 1382 subjects included, 77% did not display any signs of LVH, 6% had LVH defined by ECG only, 13% had...... LVH defined by echocardiography only, and 5% had LVH on both ECG and echocardiography. Older subjects and those with higher blood pressure and RWT were more likely to have a relatively greater LVMI on echocardiography than that predicted on ECG (odds ratio: 1.65 per 10 years (95% confidence interval...... and odds ratio: 1.41 (95% CI: 1.06-1.87), p = .02), but FPG did not independently influence discrepancy between ECG and echocardiography. CONCLUSION: Age, blood pressure, female sex, greater RWT and use of antihypertensive medication were associated with a greater risk of non-consistency between LVH...

  14. Association of heart failure hospitalizations with combined electrocardiography and echocardiography criteria for left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Gerdts, Eva; Okin, Peter M; Boman, Kurt

    2012-01-01

    The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain.......The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain....

  15. A STUDY OF ELECTROCARDIOGRAPHY AND KIDNEY FUNCTION TEST IN NEWLYDIAGNOSED HYPERTENSIVE PATIENTS IN COASTAL ANDHRA PRADESH

    Directory of Open Access Journals (Sweden)

    Ramswaroop

    2017-11-01

    Full Text Available BACKGROUND As per the fact sheet published by World Health Organisation, South East Asia, nearly one billion people have high blood pressure and are one of the most common causes of premature death worldwide. About one third of the adult population in the South East Asia region is having hypertension. In our country, the number of people with hypertension are undiagnosed and untreated, so early detection and treatment of hypertension will decrease the complication of hypertension and premature death due to it. MATERIALS AND METHODS This is a prospective study conducted in the Department of General Medicine, Konaseema Institute of Medical Sciences, Amalapuram, from May 2015 to August 2017. This study was started with an aim to know that electrocardiographic abnormalities and kidney function at the time of diagnosis of hypertension in a patient in coastal Andhra Pradesh. RESULTS We have found ECG changes in both the stages of hypertensive group patients. In stage-1 hypertensive group patients, out of 80 patients, 6 patients having sinus tachycardia, 2 having sinus bradycardia, 4 patients having left bundle-branch block and 6 having right bundle-branch block. ST elevation was found in 1 patient and ST depression was found in 8 patients. AV block was present in 2 patients. Right ventricular hypertrophy was present in 1 patient and left ventricular hypertrophy was present in 4 patients. T-wave inversion was found in 4 patients. In stage-2 hypertensive patients, sinus tachycardia in 6 patients and bradycardia in 1 patient, LBBB was found in 8 patients. ST depression was found in 6 patients and ST elevation was found in 2 patients out of 40 patients. AV block was present in 3 patients. Left ventricular hypertrophy patients 16 out of 40, but right ventricular hypertrophy was only 1. T-wave inversion was found in 6 patients. CONCLUSION In our study, we have found that stage-2 hypertensive patients have higher BMI, serum urea and creatinine than stage-1 patients. We have found that stage-2 hypertension is associated with increase in PR and QT interval. Left ventricular hypertrophy was commonest ECG abnormality detected. In our study, at the time of diagnosis, already some have developed cardiac manifestation. So, early diagnosis and management of hypertension is essential for further progress of disease.

  16. Reverse Δ-wave as a possible sign in electrocardiography to diagnose mitral valve prolapse

    Directory of Open Access Journals (Sweden)

    Alizadeh-Asl Azin

    2011-01-01

    Full Text Available Abstract Background Mitral valve prolapse (MVP is defined as superior displacement of the mitral valve leaflets more than 2 mm into the left atrium during systole. Easier and cheaper assessment of this common disease is a priority in cardiac health care facilities. Presentation of the hypothesis In this study I addressed electrocardiographic presentation in 300 patients with MVP compared with 100 healthy individuals. I faced a novel finding in electrocardiogram (ECG examination of these patients. It was a notch (reverse Δ-wave in descending arm of QRS observed in 79% (237/300 of patients, consisting of 58% (174/300 in inferior leads and 21% (63/300 in I and aVL leads. The notch was identified only in 6 men in control group. Testing the hypothesis Considering the relatively higher prevalence of disease, a population-based diagnostic clinical trial study is appropriate to test the hypothesis. Implications of the hypothesis The hypothesis on diagnostic value of reverse Δ-wave in MVP may help in decreasing the rate of unnessessary echocardiography in some patients.

  17. Long QT syndrome genotyping by electrocardiography: fact, fiction, or something in between?

    DEFF Research Database (Denmark)

    Kanters, Jørgen K.; Graff, Claus; Andersen, Mads Peter

    2006-01-01

    Diagnosis of long QT syndrome (LQTS) is difficult. A prolonged QT interval is easily overlooked, and in 10% of all patients with LQTS, the QT interval is normal. Genotyping is unfortunately not able to detect all patients and healthy subjects correctly. Although QT prolongation is the most used r...... evaluation can serve as a guide for genotyping and can reduce the costs by suggesting which gene to start sequencing, but it is fiction that the ECG can replace genotyping....

  18. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method

    Directory of Open Access Journals (Sweden)

    Lázzari Julio O.

    1998-01-01

    Full Text Available An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (k index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (k = 0.66; SE 0.02. While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  19. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method

    Directory of Open Access Journals (Sweden)

    Julio O. Lázzari

    1998-11-01

    Full Text Available An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (k index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (k = 0.66; SE 0.02. While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  20. Echocaridography, electrocardiography, and radiography of cats with dilatation cardiomyopathy, hypertrophic cardiomyopathy, and hyperyroidism

    International Nuclear Information System (INIS)

    Moise, N.S.; Dietze, A.E.; Mezza, L.E.; Strickland, D.; Erb, H.N.; Edwards, N.J.

    1986-01-01

    The echocardiographic, ECG, and radiographic findings of sequentially examined cats with dilatation cardiomyopathy (DCM, n = 7), hypertrophic cardiomyopathy (HCM, n = 8), and hyperthyroidism (HT, n = 20) were compared with those of healthy control cats (n = 11). Cats with DCM were easily differentiated from healthy cats by echocardiography and from cats with HCM and HT by a dilated left ventricle at end-diastole with a mean +/- SD of 2.20 +/- 0.36 cm, reduced fractional shortening (2.9% +/- 3.7%), reduced aortic amplitude (0.07 +/- 0.05 cm), reduced left ventricular wall amplitude (0.09 +/- 0.09 cm), and increased E-point septal separation (0.83 +/- 0.29 cm). The cats with HCM were most consistently recognized echocardiographically by increased left ventricular wall thickness at end-diastole (0.75 +/- 0.12 cm). Some cats with HT had abnormal echocardiograms with left ventricular wall hypertrophy. These cats could usually be differentiated from the cats with HCM because of normal or increased ventricular wall amplitude, aortic amplitude, or percentage of thickening of the left ventricular wall and interventricular septum. Left atrial enlargement (left atrial diameter greater than 1.57 cm or left atrium/aorta greater than 1.75) was commonly detected by the echocardiogram in cats with DCM, HCM, or HT. The echocardiogram was helpful in differentiating the type of cardiomyopathy (DCM, HCM, or HT) when plain thoracic radiographs indicated that cardiomegaly existed. The ECG may have indicated incorrectly that there was left ventricular enlargement in some cats with HT, and it did not indicate consistently that left ventricular enlargement existed when present in cats with DCM or HCM. The ECG was a poor indicator of left atrial enlargement in all cats

  1. Advanced electrocardiography can predict mitral regurgitation in cavalier king charles spaniels with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Spiljak, Maja; Petric, Alexandra; Olsen, Lisbeth Høier

    2011-01-01

    (HRV), QT variability (QTV), T-wave complexity, wave morphology and 3-D ECG. One-way ANOVA determined 21 ECG parameters, which were significantly different (P .... Clinic for Surgery and Small Animal Medicine, Veterinary Faculty, University of Ljubljana, Slovenia. 3. Department of Basic Animal and Veterinary Sciences, Faculty of Life Sciences, University of Copenhagen, Denmark. 4. Quality Control Department, Metallurgical and Chemical Industry Cinkarna Celje, INC...

  2. Twelve-lead electrocardiography in the young: physiologic and pathologic abnormalities.

    Science.gov (United States)

    Kobza, Richard; Cuculi, Florim; Abächerli, Roger; Toggweiler, Stefan; Suter, Yves; Frey, Franz; Schmid, Johann Jakob; Erne, Paul

    2012-12-01

    BACKGROUND/ OBJECTIVE: The purpose of the present study was to analyze the prevalence of physiologic and pathologic ECG abnormalities in a cohort of young conscripts that represents the whole young generation of today. ECGs of all Swiss citizens who underwent conscription for the army during a 29-month period were analyzed manually. ECGs of 43,401 conscripts (mean age 19.2 ± 1.1 years) were analyzed; 158 conscripts were female. Incomplete right bundle branch block was found in 5870 (13.5%) and left anterior fascicular block in 360 (0.83%). First-degree AV block was present in 329 (0.8%) and Mobitz type I (Wenckebach) second-degree AV block in 3 (0.01%). Early repolarization was observed in 1035 (2.4%), T-wave inversion in 39 (0.09%), and minor T-wave changes in 182 (0.42%). Brugada-like abnormalities were observed in 6 (0.01%). None of the conscripts had atrial fibrillation or flutter. ECG abnormalities can be found in a relatively large proportion of young individuals. Incomplete right bundle branch block, left fascicular block, and first-degree AV block are the most frequent findings. No conscript presented with atrial fibrillation or flutter. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  3. Fetal heart rate patterns at 20 to 24 weeks gestation as recorded by fetal electrocardiography

    Science.gov (United States)

    Hofmeyr, F; Groenewald, CA; Nel, DG; Myers, MM; Fifer, WP; Signore, C; Hankins, GDV; Odendaal, HJ

    2014-01-01

    Introduction With advancing technology it has become possible to accurately record and assess fetal heart rate (FHR) patterns from gestations as early as 20 weeks. The aim of our study was to describe early patterns of FHR, as recorded by transabdominal fetal electrocardiogram according to the Dawes-Redman criteria. Accordingly, short-term variability, basal heart rate, accelerations and decelerations were quantified at 20-24 weeks gestation among women with uncomplicated pregnancies. Methods This study was conducted in a subset of participants enrolled in a large prospective pregnancy cohort study. Our final data set consisted of 281 recordings of women with good perinatal outcomes that had undergone fetal electrocardiographic assessment as part of the Safe Passage Study. Results The success rate of the recordings was 95.4%. The mean frequency of small and large accelerations was 0.5 and 0.1 per 10 minutes respectively and that of small and large decelerations 0.3 and 0.008 per 10 minutes respectively. The mean and basal heart rates were both equal to 148.0 bpm at a median gestation of 161 days. The mean short term variation was 6.2 (SD 1.4) milliseconds and mean minute range 35.1 (SD 7.1) milliseconds. Conclusion The 20 to 24 week fetus demonstrates FHR patterns with more accelerations and decelerations, as well as higher baseline variability than was anticipated. Information from this study provides an important foundation for further, more detailed, studies of early FHR patterns. PMID:23991757

  4. Specificity of Electrocardiography and Echocardiography Changes at the Patients with the Pulmonary Embolism

    Directory of Open Access Journals (Sweden)

    Amra Macić-Džanković

    2006-11-01

    Full Text Available We evaluated electrocardiographic and echocardiographic changes of 40 patients with pulmonary thrombo-embolism proved by perfusion scintigrams. ECG-changes included sinus tachycardia or absolute tachyarrhythmia de novo, changes type Q1S3T3 and changes in right precordial leads. Analyses of echocardiography included hyperkinesis and then dilatation and apical hypokinesis of right ventricule and tricuspid regurgitation with maximal transvalvular gradients. We emphasize such a sensibility of echocardiographic changes in early estimation of pulmonary thrombo-embolism severity and necessity for echocardiography as early as possible in suspected patients.

  5. Development and significance of a fetal electrocardiogram recorded by signal-averaged high-amplification electrocardiography.

    Science.gov (United States)

    Hayashi, Risa; Nakai, Kenji; Fukushima, Akimune; Itoh, Manabu; Sugiyama, Toru

    2009-03-01

    Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.

  6. Electrocardiography as the First Step for the Further Examination of Cardiac Involvement in Myasthenia Gravis

    Directory of Open Access Journals (Sweden)

    Takao Kato

    2016-01-01

    Full Text Available Introduction. Cardiac involvement of myasthenia gravis (MG accompanies a poor prognosis. In the present study, we aimed to investigate the relationship between ECG abnormality and cardiac involvement. Methods. Of 178 patients diagnosed with MG between 2001 and 2013 at our hospital, we retrospectively analyzed consecutive 58 patients who underwent both ECG and echocardiography and without underlying cardiovascular disease. ECG abnormalities were defined by computer-assigned Minnesota-codes. Cardiac damage was defined as either (1 ejection fraction (EF 8 on echocardiography. Results. Thirty-three patients (56.8% had ECG abnormality. An elevated E/e′ was observed in patients with ECG abnormality compared to those without ECG abnormality (11.2±3.2, 8.7±2.2, resp., p=0.03. Among patients with ECG abnormality, 14 of 15 patients showed cardiac damage. Among patients without ECG abnormality, 6 of 33 patients showed cardiac damage (p=0.003. Reduced EF was observed in five patients (8.6% with ECG abnormality and none in patients without ECG abnormality. Conclusions. ECG may aid as the first step for the further examination of cardiac damage in patients with MG.

  7. Old tools for sophisticated diagnosis: Electrocardiography for the assessment of myocardial viability

    International Nuclear Information System (INIS)

    Margonato, A.; Chierchia, S.

    1996-01-01

    The identification of residual myocardial viability in patients with a previous myocardial infarction has important clinical implications. Various methods have been developed for the detection of viable myocardium, however most of them are expensive and available only to high-tech centers. In the attempt to obtain reliable information at a low cost, exercise-ECG has been proposed as a useful technique. The results of a series of studies show that ST segment elevation and ventricular arrhythmias elicited by exercise are reliable signs of the presence of reversible myocardial damage

  8. Intraoperative "Kounis syndrome" that improved electrocardiography changes and hemodynamic situation afteradministering nitroglycerine

    Directory of Open Access Journals (Sweden)

    Victoria O. Sánchez

    2014-07-01

    Full Text Available A 58-year-old female without cardiovascular risk factors, was going to be operated to repair the rotator cuff. Induction and interscalene brachial plexus block were uneventful, but after her placement for surgery the patient started with severe bronchospasm, hypotension, cutaneous allergic reaction and ST elevation on the electrocardiogram. An anaphylactic shock was suspected and treated but until the perfusion of nitroglycerina was started no electrocardiographic changes resolved. After necessary diagnostic test the final diagnosis was variant I of Kounis syndrome due to cefazolin and rocuronium. Ephinephrine is the cornerstone of treatment for anaphylaxis but should we use it if the anaphylactic reaction is also accompanied by myocardial ischemia? The answer is that we should not use it because myocardial ischemia in this syndrome is caused by vasospasm, so it would be more useful drugs such as nitroglycerin. But what if we do not know if it is a Kounis syndrome or not? In this article we report our experience that maybe could help you in a similar situation.

  9. Diagnostic value of electrocardiography, dynamic isotope studies and angiography in coronary heart disease

    International Nuclear Information System (INIS)

    Haas, J.

    1986-01-01

    The goal of this work is on the basis of the case histories of 36 patients with heart anamneses (27 with electrocardiographically and/or enzymatically detected heart infarcts, 9 with various cardial diseases) to test the diagnostic value of stress electrocardiograms, dynamic isotope examinations of the heart and coronary angiographies in the cases of myocardial infarcts, heart wall aneurysms, coronary heart disease and in the determination of the global discharge fraction, specifically broad scanning (heart front, side and back walls) as well as fine scanning (individual coronary vessel branches). In the case of myocardial infarct the stress EKG and the heart scintigraphy agree with one another to a large degree, whereby scintigraphy (with 99mTc-DPTA) in addition detects infarcted myocardial regions. In the diagnosis of heart wall aneurysms scintigraphy and ventriculography had the same results in 91.6% of the cases. Coronary heart disease results agreed for all three methods in 91.7% of the cases and with scintigraphy and angiography in 94.4%. The degree of agreement between scintigraphy and coronary angiography is confirmed in the literature. One-, two- and 3-vessel diseases can be determined with these two methods in 90 to 75% agreement. The result lies thereby above the values of 201Tl-myocardial scintigraphy given in the literature. Also the global discharge fraction shows scintigraphic as well as angiographic agreement of almost 90%. (TRV) [de

  10. Myocardial scintigraphy (thallium-201) and electrocardiography at rest and during exercise in angina pectoris

    International Nuclear Information System (INIS)

    Minning, E.; Scharf-Bornhofen, E.; Brueggeman, Th.; Chen, T.; Barthel, W.; Bluemchen, G.; Sankt-Josef-Hospital, Oberhausen

    1980-01-01

    Ecg (at rest and during exercise) was compared to Thallium-201 myocardial perfusion imaging (at rest and after exercise) in 65 patients with coronary heart disease (myocardial infarction in 53 patients) and angina pectoris. These results were compared to coronary angiography and left ventricular angiography. (orig./AJ) [de

  11. Securing While Sampling in Wireless Body Area Networks With Application to Electrocardiography.

    Science.gov (United States)

    Dautov, Ruslan; Tsouri, Gill R

    2016-01-01

    Stringent resource constraints and broadcast transmission in wireless body area network raise serious security concerns when employed in biomedical applications. Protecting data transmission where any minor alteration is potentially harmful is of significant importance in healthcare. Traditional security methods based on public or private key infrastructure require considerable memory and computational resources, and present an implementation obstacle in compact sensor nodes. This paper proposes a lightweight encryption framework augmenting compressed sensing with wireless physical layer security. Augmenting compressed sensing to secure information is based on the use of the measurement matrix as an encryption key, and allows for incorporating security in addition to compression at the time of sampling an analog signal. The proposed approach eliminates the need for a separate encryption algorithm, as well as the predeployment of a key thereby conserving sensor node's limited resources. The proposed framework is evaluated using analysis, simulation, and experimentation applied to a wireless electrocardiogram setup consisting of a sensor node, an access point, and an eavesdropper performing a proximity attack. Results show that legitimate communication is reliable and secure given that the eavesdropper is located at a reasonable distance from the sensor node and the access point.

  12. A blended learning program on undergraduate nursing students' learning of electrocardiography.

    Science.gov (United States)

    Jang, Keum-Seong; Kim, Yun-Min; Park, Soon-Joo

    2006-01-01

    This study sought to evaluate the feasibility of applying the blended learning program that combines the advantages of face-to-face(FTF) learning and e-learning. The blended learning program was developed by the authors and implemented for 4 weeks. 56 senior nursing students were recruited at a university in Korea. Significant improvement was noted in learning achievement. No significant differences were noted between FTF and web-based learning in learning motivation. Learning satisfaction and students' experience in taking this course revealed some positive effects of blended learning. The use of blended learning program for undergraduate nursing students will provide an effective learning model.

  13. Differences in alarm events between disposable and reusable electrocardiography lead wires.

    Science.gov (United States)

    Albert, Nancy M; Murray, Terri; Bena, James F; Slifcak, Ellen; Roach, Joel D; Spence, Jackie; Burkle, Alicia

    2015-01-01

    Disposable electrocardiographic lead wires (ECG-LWs) may not be as durable as reusable ones. To examine differences in alarm events between disposable and reusable ECG-LWs. Two cardiac telemetry units were randomized to reusable ECG-LWs, and 2 units alternated between disposable and reusable ECG-LWs for 4 months. A remote monitoring team, blinded to ECG-LW type, assessed frequency and type of alarm events by using total counts and rates per 100 patient days. Event rates were compared by using generalized linear mixed-effect models for differences and noninferiority between wire types. In 1611 patients and 9385.5 patient days of ECG monitoring, patient characteristics were similar between groups. Rates of alarms for no telemetry, leads fail, or leads off were lower in disposable ECG-LWs (adjusted relative risk [95% CI], 0.71 [0.53-0.96]; noninferiority P < .001; superiority P = .03) and monitoring (artifact) alarms were significantly noninferior (adjusted relative risk [95% CI]: 0.88, [0.62-1.24], P = .02; superiority P = .44). No between-group differences existed in false or true crisis alarms. Disposable ECG-LWs were noninferior to reusable ECG-LWs for all false-alarm events (N [rate per 100 patient days], disposable 2029 [79.1] vs reusable 6673 [97.9]; adjusted relative risk [95% CI]: 0.81 [0.63-1.06], P = .002; superiority P = .12.) Disposable ECG-LWs with patented push-button design had superior performance in reducing alarms created by no telemetry, leads fail, or leads off and significant noninferiority in all false-alarm rates compared with reusable ECG-LWs. Fewer ECG alarms may save nurses time, decrease alarm fatigue, and improve patient safety. ©2015 American Association of Critical-Care Nurses.

  14. Social Comparison in the Classroom : A Review

    NARCIS (Netherlands)

    Dijkstra, Pieternel; Kuyper, Hans; van der Werf, Greetje; Buunk, Abraham P.; van der Zee, Yvonne G.

    2008-01-01

    This article reviews research conducted on social comparison processes in the classroom since Festinger proposed his theory of social comparison. It covers the theoretical framework of social comparison theory, and it is organized around the following themes: motives for social comparison,

  15. Generating explanations via analogical comparison.

    Science.gov (United States)

    Hoyos, Christian; Gentner, Dedre

    2017-10-01

    Generating explanations can be highly effective in promoting learning in both adults and children. Our interest is in the mechanisms that underlie this effect and in whether and how they operate in early learning. In adult reasoning, explanation may call on many subprocesses-including comparison, counterfactual reasoning, and reasoning by exclusion; but it is unlikely that all these processes are available to young children. We propose that one process that may serve both children and adults is comparison. In this study, we asked whether children would use the results of a comparison experience when asked to explain why a model skyscraper was stable. We focused on a challenging principle-that diagonal cross-bracing lends stability to physical structures (Gentner et al., Cognitive Science, 40, 224-240, 2016). Six-year-olds either received no training or interacted with model skyscrapers in one of three different conditions, designed to vary in their potential to invite and support comparison. In the Single Model condition, children interacted with a single braced model. In the comparison conditions (Low Alignability and High Alignability), children compared braced and unbraced models. Following experience with the models, children were asked to explain why the braced model was stable. They then received two transfer tasks. We found that children who received highly alignable pairs were most likely to (a) produce brace-based explanations and (b) transfer the brace principle to a dissimilar context. This provides evidence that children can benefit from analogical comparison in generating explanations and also suggests limitations on this ability.

  16. Austrian emission under international comparison

    International Nuclear Information System (INIS)

    Anderl, M.; Gager, M.; Gugele, B.; Huttunen, K.; Kurzweil, A.; Poupa, S.; Ritter, M.; Wappel, D.; Wieser, M.

    2004-01-01

    A comparison between anthropogenic emissions of CO 2 , CH 4 , N 2 O, SO 2 , NO x , volatile organic compounds (NMVOC), NH 3 and CO from the European Union, European Union candidate countries and Austria is presented. Data covers the years 1999-2001 and the emissions values per habitant are provided as well as a comparison against the Kyoto goals. In the middle of the European mean values are the austrian emissions values, austrian SO 2 emissions are the smallest, however CH 4 , CO and NMVOC emissions are over the European mean values. 8 figs., 6 tabs. (nevyjel)

  17. Ordinal Comparison of Multidimensional Deprivation

    DEFF Research Database (Denmark)

    Sonne-Schmidt, Christoffer Scavenius; Tarp, Finn; Østerdal, Lars Peter

    This paper develops an ordinal method of comparison of multidimensional inequality. In our model, population distribution g is more unequal than f when the distributions have common median and can be obtained from f  by one or more shifts in population density that increase inequality. For our be...... benchmark 2x2 case (i.e. the case of two binary outcome variables), we derive an empirical method for making inequality comparisons. As an illustration, we apply the model to childhood poverty in Mozambique....

  18. Metamodel comparison and model comparison for safety assurance

    NARCIS (Netherlands)

    Luo, Y.; Engelen, L.J.P.; Brand, van den M.G.J.; Bondavelli, A.; Ceccarelli, A.; Ortmeier, F.

    2014-01-01

    In safety-critical domains, conceptual models are created in the form of metamodels using different concepts from possibly overlapping domains. Comparison between those conceptual models can facilitate the reuse of models from one domain to another. This paper describes the mappings detected when

  19. Image quality in non-gated versus gated reconstruction of tongue motion using magnetic resonance imaging: a comparison using automated image processing

    Energy Technology Data Exchange (ETDEWEB)

    Alvey, Christopher; Orphanidou, C.; Coleman, J.; McIntyre, A.; Golding, S.; Kochanski, G. [University of Oxford, Oxford (United Kingdom)

    2008-11-15

    The use of gated or ECG triggered MR is a well-established technique and developments in coil technology have enabled this approach to be applied to areas other than the heart. However, the image quality of gated (ECG or cine) versus non-gated or real-time has not been extensively evaluated in the mouth. We evaluate two image sequences by developing an automatic image processing technique which compares how well the image represents known anatomy. Four subjects practised experimental poly-syllabic sentences prior to MR scanning. Using a 1.5 T MR unit, we acquired comparable gated (using an artificial trigger) and non-gated sagittal images during speech. We then used an image processing algorithm to model the image grey along lines that cross the airway. Each line involved an eight parameter non-linear equation to model of proton densities, edges, and dimensions. Gated and non-gated images show similar spatial resolution, with non-gated images being slightly sharper (10% better resolution, less than 1 pixel). However, the gated sequences generated images of substantially lower inherent noise, and substantially better discrimination between air and tissue. Additionally, the gated sequences demonstrate a very much greater temporal resolution. Overall, image quality is better with gated imaging techniques, especially given their superior temporal resolution. Gated techniques are limited by the repeatability of the motions involved, and we have shown that speech to a metronome can be sufficiently repeatable to allow high-quality gated magnetic resonance imaging images. We suggest that gated sequences may be useful for evaluating other types of repetitive movement involving the joints and limb motions. (orig.)

  20. Image quality in non-gated versus gated reconstruction of tongue motion using magnetic resonance imaging: a comparison using automated image processing

    International Nuclear Information System (INIS)

    Alvey, Christopher; Orphanidou, C.; Coleman, J.; McIntyre, A.; Golding, S.; Kochanski, G.

    2008-01-01

    The use of gated or ECG triggered MR is a well-established technique and developments in coil technology have enabled this approach to be applied to areas other than the heart. However, the image quality of gated (ECG or cine) versus non-gated or real-time has not been extensively evaluated in the mouth. We evaluate two image sequences by developing an automatic image processing technique which compares how well the image represents known anatomy. Four subjects practised experimental poly-syllabic sentences prior to MR scanning. Using a 1.5 T MR unit, we acquired comparable gated (using an artificial trigger) and non-gated sagittal images during speech. We then used an image processing algorithm to model the image grey along lines that cross the airway. Each line involved an eight parameter non-linear equation to model of proton densities, edges, and dimensions. Gated and non-gated images show similar spatial resolution, with non-gated images being slightly sharper (10% better resolution, less than 1 pixel). However, the gated sequences generated images of substantially lower inherent noise, and substantially better discrimination between air and tissue. Additionally, the gated sequences demonstrate a very much greater temporal resolution. Overall, image quality is better with gated imaging techniques, especially given their superior temporal resolution. Gated techniques are limited by the repeatability of the motions involved, and we have shown that speech to a metronome can be sufficiently repeatable to allow high-quality gated magnetic resonance imaging images. We suggest that gated sequences may be useful for evaluating other types of repetitive movement involving the joints and limb motions. (orig.)

  1. Comparison between TRMM PR and

    Indian Academy of Sciences (India)

    A comparison between TRMM PR rainfall estimates and rain gauge data from ANEEL and com- bined gauge/satellite ..... correctly the of the south Atlantic convergence ..... vapor, snow cover, and sea ice derived from SSM/I mea- surements ...

  2. Saliency of social comparison dimensions

    NARCIS (Netherlands)

    Kuyper, H.

    2007-01-01

    The present article discusses a theory of the saliency of social comparison dimensions and presents the results of an experiment about the effects of two different experimental situations on the saliency of exterior, task-related and socio-emotional dimensions. Saliency was operationalized with a

  3. Homomorphic encryption and secure comparison

    NARCIS (Netherlands)

    Damgard, Ivan; Geisler, M.; Kroigaard, M.

    2008-01-01

    We propose a protocol for secure comparison of integers based on homomorphic encryption.We also propose a homomorphic encryption scheme that can be used in our protocol, makes it more efficient than previous solutions, and can also be used as the basis of efficient and general secure Multiparty

  4. Aggregation Methods in International Comparisons

    NARCIS (Netherlands)

    B.M. Balk (Bert)

    2001-01-01

    textabstractThis paper reviews the progress that has been made over the past decade in understanding the nature of the various multilateral in- ternational comparison methods. Fifteen methods are discussed and subjected to a system of ten tests. In addition, attention is paid to recently developed

  5. Quantum secure communication models comparison

    Directory of Open Access Journals (Sweden)

    Georgi Petrov Bebrov

    2017-12-01

    Full Text Available The paper concerns the quantum cryptography, more specifically, the quantum secure communication type of schemes. The main focus here is on making a comparison between the distinct secure quantum communication models – quantum secure direct communication and deterministic secure quantum communication, in terms of three parameters: resource efficiency, eavesdropping check efficiency, and security (degree of preserving the confidentiality.

  6. Doppler Ultrasound Triggering for Cardiovascular MRI at 3T in a Healthy Volunteer Study.

    Science.gov (United States)

    Kording, Fabian; Yamamura, Jin; Lund, Gunnar; Ueberle, Friedrich; Jung, Caroline; Adam, Gerhard; Schoennagel, Bjoern Philip

    2017-04-10

    Electrocardiogram (ECG) triggering for cardiac magnetic resonance (CMR) may be influenced by electromagnetic interferences with increasing magnetic field strength. The aim of this study was to evaluate the performance of Doppler ultrasound (DUS) as an alternative trigger technique for CMR in comparison to ECG and pulse oximetry (POX) at 3T and using different sequence types. Balanced turbo field echo two-dimensional (2D) short axis cine CMR and 2D phase-contrast angiography of the ascending aorta was performed in 11 healthy volunteers at 3T using ECG, DUS, and POX for cardiac triggering. DUS and POX triggering were compared to the reference standard of ECG in terms of trigger quality (trigger detection and temporal variability), image quality [endocardial blurring (EB)], and functional measurements [left ventricular (LV) volumetry and aortic blood flow velocimetry]. Trigger signal detection and temporal variability did not differ significantly between ECG/DUS (I = 0.6) and ECG/POX (P = 0.4). Averaged EB was similar for ECG, DUS, and POX (p ECG/DUS = 0.4, p ECG/POX = 0.9). Diastolic EB was significantly decreased for DUS in comparison to ECG (P = 0.02) and POX (P = 0.04). The LV function assessment and aortic blood flow were not significantly different. This study demonstrated the feasibility of DUS for gating human CMR at 3T. The magnetohydrodynamic effect did not significantly disturb ECG triggering in this small healthy volunteer study. DUS showed a significant improvement in diastolic EB but could not be identified as a superior trigger method. The potential benefit of DUS has to be evaluated in a larger clinical patient population.

  7. Pluralism and Objectivism: Cornerstones for Interpersonal Comparisons

    DEFF Research Database (Denmark)

    Nielsen, Lasse

    2012-01-01

    comparison, and between a subjectivist and objectivist standard of interpersonal comparison. The paper provides a normative argument for pluralism and objectivism with regard to interpersonal comparison, and it suggests that the Capability Approach as developed by Amartya Sen and Martha Nussbaum fits...

  8. Cross-National Yardstick Comparisons

    DEFF Research Database (Denmark)

    Møller Hansen, Kasper; Leth Olsen, Asmus; Bech, Mickael

    2015-01-01

    performance comparisons—even when accounting for classic national sociotropic and egotropic items. Specifically, voters respond strongly to how the prospective wealth of Denmark evolves relative to the neighboring Sweden. Interestingly, voters are more negative in their response to cross-national losses......Comparing performance between countries is both a theoretically and intuitively useful yardstick for voters. Cross-national comparisons provide voters with heuristics that are less cognitively demanding, less ambiguous, and less uncertain than solely national, absolute performance measurements. We...... test this proposition using a unique, choice experiment embedded in the 2011 Danish National Election Study. This design allows to contrast cross-national comparisons with more traditional national sociotropic and egotropic concerns. The findings suggest that voters are strongly influenced by cross-national...

  9. Numerical Tokamak Project code comparison

    International Nuclear Information System (INIS)

    Waltz, R.E.; Cohen, B.I.; Beer, M.A.

    1994-01-01

    The Numerical Tokamak Project undertook a code comparison using a set of TFTR tokamak parameters. Local radial annulus codes of both gyrokinetic and gyrofluid types were compared for both slab and toroidal case limits assuming ion temperature gradient mode turbulence in a pure plasma with adiabatic electrons. The heat diffusivities were found to be in good internal agreement within ± 50% of the group average over five codes

  10. Comparison of BIOPATH and MARCEN

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, R.A.; Barrdahl, R. [Swedish Radiation Protection Inst., Stockholm (Sweden); Bergstroem, U.; Nordlinder, S. [Studsvik Eco and Safety AB, Nykoeping (Sweden)

    1995-11-01

    The present report discusses a comparison of two models for assessing the environmental transfer of radionuclides from routine releases to the sea from nuclear power plants: BIOPATH and MARCEN. The purpose of the comparison was to assess the credibility of MARCEN`s predictions of doses to critical groups. BIOPATH, which has previously been validated and compared with other models, was a suitable code for this purpose. The releases from Ringhals during 1993 were used for the comparison. For this scenario BIOPATH and MARCEN predicted the same critical radionuclide/pathway combinations. The observed quantitative disagreement between the models was mainly due to scale differences. The ratio of the mean values predicted by BIOPATH and MARCEN ranged from 0.91 ({sup 60}Co/shellfish) to 2.43 ({sup 137}Cs/fish). The observed differences between the models are small in general, and can be neglected if the predicted doses are one or more orders of magnitude below the dose limits. 8 refs, 12 figs, 9 tabs.

  11. Comparison of BIOPATH and MARCEN

    International Nuclear Information System (INIS)

    Moreno, R.A.; Barrdahl, R.; Bergstroem, U.; Nordlinder, S.

    1995-11-01

    The present report discusses a comparison of two models for assessing the environmental transfer of radionuclides from routine releases to the sea from nuclear power plants: BIOPATH and MARCEN. The purpose of the comparison was to assess the credibility of MARCEN's predictions of doses to critical groups. BIOPATH, which has previously been validated and compared with other models, was a suitable code for this purpose. The releases from Ringhals during 1993 were used for the comparison. For this scenario BIOPATH and MARCEN predicted the same critical radionuclide/pathway combinations. The observed quantitative disagreement between the models was mainly due to scale differences. The ratio of the mean values predicted by BIOPATH and MARCEN ranged from 0.91 ( 60 Co/shellfish) to 2.43 ( 137 Cs/fish). The observed differences between the models are small in general, and can be neglected if the predicted doses are one or more orders of magnitude below the dose limits. 8 refs, 12 figs, 9 tabs

  12. Ascertainment and comparison of risks

    International Nuclear Information System (INIS)

    Devooght, J.

    1981-01-01

    The author reviews the major problems arising from a comparison and an ascertainment of risks. Extensive scattering shown in the results from ten different studies reflect statistical inadequacies as well as differences in methodological approach. The controversy over renewable energy sources illustrates how the use of different criteria produce different results. Each source of energy (except coal) has practically the same number of lost working days as well as deaths per worker unit, but the risks are lower using nuclear energy as opposed to other sources if calculated pro unit or produced energy. Despite considerable uncertainty over the consequences of nuclear accidents, comparative nuclear energy shows up very favourably. (AF)

  13. Comparison of tritium production facilities

    International Nuclear Information System (INIS)

    He Kaihui; Huang Jinhua

    2002-01-01

    Detailed investigation and research on the source of tritium, tritium production facilities and their comparison are presented based on the basic information about tritium. The characteristics of three types of proposed tritium production facilities, i.e., fissile type, accelerator production tritium (APT) and fusion type, are presented. APT shows many advantages except its rather high cost; fusion reactors appear to offer improved safety and environmental impacts, in particular, tritium production based on the fusion-based neutron source costs much lower and directly helps the development of fusion energy source

  14. Comparison of Nordic dose models

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.

    1978-04-01

    A comparison is made between the models used in the four Nordic countries, Finland, Norway, Sweden and Denmark, for calculation of concentrations and doses from releases of radioactive material to the atmosphere. The comparison is limited to the near-zone models, i.e. the models for calculation of concentrations and doses within 50 km from the release point, and it comprises the following types of calculation: a. Concentrations of airborne material, b. External gamma doses from a plume, c. External gamma doses from radioactive material deposited on the ground. All models are based on the gaussian dispersion model (the gaussian plume model). Unit releases of specific isotopes under specific meteorological conditions are assumed. On the basis of the calculation results from the models, it is concluded that there are no essential differences. The difference between the calculation results only exceeds a factor of 3 in special cases. It thus lies within the known limits of uncertainty for the gaussian plume model. (author)

  15. RISKIND verification and benchmark comparisons

    International Nuclear Information System (INIS)

    Biwer, B.M.; Arnish, J.J.; Chen, S.Y.; Kamboj, S.

    1997-08-01

    This report presents verification calculations and benchmark comparisons for RISKIND, a computer code designed to estimate potential radiological consequences and health risks to individuals and the population from exposures associated with the transportation of spent nuclear fuel and other radioactive materials. Spreadsheet calculations were performed to verify the proper operation of the major options and calculational steps in RISKIND. The program is unique in that it combines a variety of well-established models into a comprehensive treatment for assessing risks from the transportation of radioactive materials. Benchmark comparisons with other validated codes that incorporate similar models were also performed. For instance, the external gamma and neutron dose rate curves for a shipping package estimated by RISKIND were compared with those estimated by using the RADTRAN 4 code and NUREG-0170 methodology. Atmospheric dispersion of released material and dose estimates from the GENII and CAP88-PC codes. Verification results have shown the program to be performing its intended function correctly. The benchmark results indicate that the predictions made by RISKIND are within acceptable limits when compared with predictions from similar existing models

  16. RISKIND verification and benchmark comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Biwer, B.M.; Arnish, J.J.; Chen, S.Y.; Kamboj, S.

    1997-08-01

    This report presents verification calculations and benchmark comparisons for RISKIND, a computer code designed to estimate potential radiological consequences and health risks to individuals and the population from exposures associated with the transportation of spent nuclear fuel and other radioactive materials. Spreadsheet calculations were performed to verify the proper operation of the major options and calculational steps in RISKIND. The program is unique in that it combines a variety of well-established models into a comprehensive treatment for assessing risks from the transportation of radioactive materials. Benchmark comparisons with other validated codes that incorporate similar models were also performed. For instance, the external gamma and neutron dose rate curves for a shipping package estimated by RISKIND were compared with those estimated by using the RADTRAN 4 code and NUREG-0170 methodology. Atmospheric dispersion of released material and dose estimates from the GENII and CAP88-PC codes. Verification results have shown the program to be performing its intended function correctly. The benchmark results indicate that the predictions made by RISKIND are within acceptable limits when compared with predictions from similar existing models.

  17. Angle comparison using an autocollimator

    Science.gov (United States)

    Geckeler, Ralf D.; Just, Andreas; Vasilev, Valentin; Prieto, Emilio; Dvorácek, František; Zelenika, Slobodan; Przybylska, Joanna; Duta, Alexandru; Victorov, Ilya; Pisani, Marco; Saraiva, Fernanda; Salgado, Jose-Antonio; Gao, Sitian; Anusorn, Tonmueanwai; Leng Tan, Siew; Cox, Peter; Watanabe, Tsukasa; Lewis, Andrew; Chaudhary, K. P.; Thalmann, Ruedi; Banreti, Edit; Nurul, Alfiyati; Fira, Roman; Yandayan, Tanfer; Chekirda, Konstantin; Bergmans, Rob; Lassila, Antti

    2018-01-01

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (+/-10 arcsec and +/-1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Review of interspecies risk comparisons

    International Nuclear Information System (INIS)

    Brown, S.L.; Brett, S.M.; Gough, M.; Rodricks, J.V.; Tardiff, R.G.; Turnbull, D.

    1988-01-01

    Use of laboratory animal data to make quantitative predictions of the risks of toxic effects in humans assumes that a relationship exists between the potencies in animals and humans and that its parameters can be estimated adequately. Such ''scaling rules'' have been used to predict the risks of carcinogenicity or other effects. A survey of the literature yielded only a modest number of papers devoted to the validity of these interspecies risk extrapolations, of which approximately 25 attempt quantitative comparisons for either radiation or chemical hazards. Some authors have investigated relatively large data sets in an attempt to identify the scaling rule that provides the best correlation of risks in two or more species. Others have selected a scaling rule and investigated whether its predictions from data in laboratory species match the risks found in humans. Opinion is divided on the validity of specific extrapolation rules and the utility of animal experiments for quantitative risk assessment. Correlations exist among risk levels in various species, but many factors appear to influence toxicity that are not captured in a simple scaling rule such as dose per unit weight or per unit surface area. Although scaling rules are useful, better projections will be made if case-specific factors such as pharmacokinetics can be considered. Further careful comparisons of quantitative risk estimates are needed. 38 references

  19. Efficient RNA structure comparison algorithms.

    Science.gov (United States)

    Arslan, Abdullah N; Anandan, Jithendar; Fry, Eric; Monschke, Keith; Ganneboina, Nitin; Bowerman, Jason

    2017-12-01

    Recently proposed relative addressing-based ([Formula: see text]) RNA secondary structure representation has important features by which an RNA structure database can be stored into a suffix array. A fast substructure search algorithm has been proposed based on binary search on this suffix array. Using this substructure search algorithm, we present a fast algorithm that finds the largest common substructure of given multiple RNA structures in [Formula: see text] format. The multiple RNA structure comparison problem is NP-hard in its general formulation. We introduced a new problem for comparing multiple RNA structures. This problem has more strict similarity definition and objective, and we propose an algorithm that solves this problem efficiently. We also develop another comparison algorithm that iteratively calls this algorithm to locate nonoverlapping large common substructures in compared RNAs. With the new resulting tools, we improved the RNASSAC website (linked from http://faculty.tamuc.edu/aarslan ). This website now also includes two drawing tools: one specialized for preparing RNA substructures that can be used as input by the search tool, and another one for automatically drawing the entire RNA structure from a given structure sequence.

  20. Comparison of turbulence mitigation algorithms

    Science.gov (United States)

    Kozacik, Stephen T.; Paolini, Aaron; Sherman, Ariel; Bonnett, James; Kelmelis, Eric

    2017-07-01

    When capturing imagery over long distances, atmospheric turbulence often degrades the data, especially when observation paths are close to the ground or in hot environments. These issues manifest as time-varying scintillation and warping effects that decrease the effective resolution of the sensor and reduce actionable intelligence. In recent years, several image processing approaches to turbulence mitigation have shown promise. Each of these algorithms has different computational requirements, usability demands, and degrees of independence from camera sensors. They also produce different degrees of enhancement when applied to turbulent imagery. Additionally, some of these algorithms are applicable to real-time operational scenarios while others may only be suitable for postprocessing workflows. EM Photonics has been developing image-processing-based turbulence mitigation technology since 2005. We will compare techniques from the literature with our commercially available, real-time, GPU-accelerated turbulence mitigation software. These comparisons will be made using real (not synthetic), experimentally obtained data for a variety of conditions, including varying optical hardware, imaging range, subjects, and turbulence conditions. Comparison metrics will include image quality, video latency, computational complexity, and potential for real-time operation. Additionally, we will present a technique for quantitatively comparing turbulence mitigation algorithms using real images of radial resolution targets.

  1. Comparison of sodium aerosol codes

    International Nuclear Information System (INIS)

    Dunbar, I.H.; Fermandjian, J.; Bunz, H.; L'homme, A.; Lhiaubet, G.; Himeno, Y.; Kirby, C.R.; Mitsutsuka, N.

    1984-01-01

    Although hypothetical fast reactor accidents leading to severe core damage are very low probability events, their consequences are to be assessed. During such accidents, one can envisage the ejection of sodium, mixed with fuel and fission products, from the primary circuit into the secondary containment. Aerosols can be formed either by mechanical dispersion of the molten material or as a result of combustion of the sodium in the mixture. Therefore considerable effort has been devoted to study the different sodium aerosol phenomena. To ensure that the problems of describing the physical behaviour of sodium aerosols were adequately understood, a comparison of the codes being developed to describe their behaviour was undertaken. The comparison consists of two parts. The first is a comparative study of the computer codes used to predict aerosol behaviour during a hypothetical accident. It is a critical review of documentation available. The second part is an exercise in which code users have run their own codes with a pre-arranged input. For the critical comparative review of the computer models, documentation has been made available on the following codes: AEROSIM (UK), MAEROS (USA), HAARM-3 (USA), AEROSOLS/A2 (France), AEROSOLS/B1 (France), and PARDISEKO-IIIb (FRG)

  2. Computational Chemistry Comparison and Benchmark Database

    Science.gov (United States)

    SRD 101 NIST Computational Chemistry Comparison and Benchmark Database (Web, free access)   The NIST Computational Chemistry Comparison and Benchmark Database is a collection of experimental and ab initio thermochemical properties for a selected set of molecules. The goals are to provide a benchmark set of molecules for the evaluation of ab initio computational methods and allow the comparison between different ab initio computational methods for the prediction of thermochemical properties.

  3. European Measurement Comparisons of Environmental Radioactivity

    International Nuclear Information System (INIS)

    Waetjen, Uwe

    2008-01-01

    The scheme of European measurement comparisons to verify radioactivity monitoring in the European Union is briefly explained. After a review of comparisons conducted during the years 1990, the approach of IRMM organising these comparisons since 2003 is presented. IRMM is providing comparison samples with a reference value traceable to the SI units and which is fully documented to all participants and national authorities after completion of the comparison. The sample preparation and determination of traceable reference values at IRMM, the sample treatment and measurement in the participating laboratories, as well as the evaluation of comparison results are described in some detail using the example of an air filter comparison. The results of a comparison to determine metabolised 40 K, 90 Sr and 137 Cs in milk powder are presented as well. The necessary improvements in the estimation of measurement uncertainty by the participating laboratories are discussed. The performance of individual laboratories which have participated in at least four comparison exercises over the years is studied in terms of observable trends

  4. The neural correlates of beauty comparison.

    Science.gov (United States)

    Kedia, Gayannée; Mussweiler, Thomas; Mullins, Paul; Linden, David E J

    2014-05-01

    Beauty is in the eye of the beholder. How attractive someone is perceived to be depends on the individual or cultural standards to which this person is compared. But although comparisons play a central role in the way people judge the appearance of others, the brain processes underlying attractiveness comparisons remain unknown. In the present experiment, we tested the hypothesis that attractiveness comparisons rely on the same cognitive and neural mechanisms as comparisons of simple nonsocial magnitudes such as size. We recorded brain activity with functional magnetic resonance imaging (fMRI) while participants compared the beauty or height of two women or two dogs. Our data support the hypothesis of a common process underlying these different types of comparisons. First, we demonstrate that the distance effect characteristic of nonsocial comparisons also holds for attractiveness comparisons. Behavioral results indicated, for all our comparisons, longer response times for near than far distances. Second, the neural correlates of these distance effects overlapped in a frontoparietal network known for its involvement in processing simple nonsocial quantities. These results provide evidence for overlapping processes in the comparison of physical attractiveness and nonsocial magnitudes.

  5. Comparison Direction and Comparison Dimension among Disabled Individuals: Toward a Refined Conceptualization of Social Comparison under Stress.

    Science.gov (United States)

    Buunk, Bram P.

    1995-01-01

    Illuminates the nature and direction of social comparison research using a sample of 168 Dutch individuals. Some of the findings revealed uncertainty and frustration related to a need for social comparison, a desire more for information than affiliation about similar others, and the influence of health problems in evaluating one's situation. (RJM)

  6. MCNPX Model/Table Comparison

    International Nuclear Information System (INIS)

    Hendricks, J.S.

    2003-01-01

    MCNPX is a Monte Carlo N-Particle radiation transport code extending the capabilities of MCNP4C. As with MCNP, MCNPX uses nuclear data tables to transport neutrons, photons, and electrons. Unlike MCNP, MCNPX also uses (1) nuclear data tables to transport protons; (2) physics models to transport 30 additional particle types (deuterons, tritons, alphas, pions, muons, etc.); and (3) physics models to transport neutrons and protons when no tabular data are available or when the data are above the energy range (20 to 150 MeV) where the data tables end. MCNPX can mix and match data tables and physics models throughout a problem. For example, MCNPX can model neutron transport in a bismuth germinate (BGO) particle detector by using data tables for bismuth and oxygen and using physics models for germanium. Also, MCNPX can model neutron transport in UO 2 , making the best use of physics models and data tables: below 20 MeV, data tables are used; above 150 MeV, physics models are used; between 20 and 150 MeV, data tables are used for oxygen and models are used for uranium. The mix-and-match capability became available with MCNPX2.5.b (November 2002). For the first time, we present here comparisons that calculate radiation transport in materials with various combinations of data charts and model physics. The physics models are poor at low energies (<150 MeV); thus, data tables should be used when available. Our comparisons demonstrate the importance of the mix-and-match capability and indicate how well physics models work in the absence of data tables

  7. Advanced nuclear systems in comparison

    International Nuclear Information System (INIS)

    Brogli, R.; Foskolos, K.; Goetzmann, C.; Kroeger, W.; Stanculescu, A.; Wydler, P.

    1996-09-01

    This study aims at a comparison of future reactor concepts, paying particular attention to aspects of safety, of the fuel cycle, the economics, the experience-base and the state of development. Representative examples of typical development lines, that could possibly be 'of interest' within a time horizon of 50 years were selected for comparison. This can be divided into three phases: - Phase I includes the next 10 years and will be characterised mainly by evolutionary developments of light water reactors (LWR) of large size; representative: EPR, - Phase II: i.e. the time between 2005 and 2020 approximately, encompasses the forecasted doubling of today's world-wide installed nuclear capacity; along with evolutionary reactors, innovative systems like AP600, PIUS, MHTGR, EFR will emerge, - Phase III covers the time between 2020 and 2050 and is characterised by the issue of sufficient fissile material resources; novel fast reactor systems including hybrid systems can, thus, become available; representatives: IFR, EA, ITER (the latter being). The evaluated concepts foresee partly different fuel cycles. Fission reactors can be operated in principle on the basis of either a Uranium-Plutonium-cycle or a Thorium-Uranium-cycle, while combinations of these cycles among them or with other reactor concepts than proposed are possible. With today's nuclear park (comprising mainly LWRs), the world-wide plutonium excess increases annually by about 100 t. Besides strategies based on reprocessing like: - recycling in thermal and fast reactors with mixed oxide fuels, - plutonium 'burning' in reactors with novel fuels without uranium or in 'hybrid' systems, allowing a reduction of this excess, direct disposal of spent fuel elements including their plutonium content ('one-through') is being considered. (author) figs., tabs., 32 refs

  8. Individual differences in social comparison : Development of a scale of social comparison orientation

    NARCIS (Netherlands)

    Gibbons, FX; Buunk, BP

    Development and validation of a measure of individual differences in social comparison orientation (the Iowa-Netherlands Comparison Orientation Measure [INCOM]) are described. Assuming that the tendency toward social comparison is universal, the scale was constructed so as to be appropriate to and

  9. Neuroticism and social comparison orientation as moderators of affective responses to social comparison at work

    NARCIS (Netherlands)

    Buunk, Abraham P.; Van der Zee, K.I.; Van Yperen, N.W.

    2001-01-01

    In a study among 72 nurses, the affective consequences of social comparison were examined and related to neuroticism, (N) and to social comparison orientation (SCO). Participants were confronted with a bogus interview with an upward versus a downward comparison target. Positive affect and

  10. Neuroticism and social comparison orientation as moderators of affective responses to social comparison at work

    NARCIS (Netherlands)

    Buunk, Bram P.; Van der Zee, K.I.; VanYperen, Nico W.

    2001-01-01

    In a study among 72 nurses, the affective consequences of social comparison were examined and related to neuroticism (N) and to social comparison orientation (SCO). Participants were confronted with a bogus interview with an upward versus a downward comparison target. Positive affect and

  11. Projected cost comparison of nuclear electricity

    International Nuclear Information System (INIS)

    Juhn, P.E.; Hu, C.W.

    2000-01-01

    Comparison of electricity generation costs has been done in the late years through a large co-operation between several organisations. The studies are aiming to provide reliable comparison of electricity generating costs of nuclear and conventional base load power plants. This paper includes the result of the joint IAEA/OECD study published in 1997. (author)

  12. The distribution of interlaboratory comparison data

    DEFF Research Database (Denmark)

    Heydorn, Kaj

    2008-01-01

    The distribution of mutually consistent results from interlaboratory comparisons is expected to be leptokurtic, and readers are warned against accepting conclusions based on simulations assuming normality.......The distribution of mutually consistent results from interlaboratory comparisons is expected to be leptokurtic, and readers are warned against accepting conclusions based on simulations assuming normality....

  13. Comparison of TRAC calculations with experimental data

    International Nuclear Information System (INIS)

    Jackson, J.F.; Vigil, J.C.

    1980-01-01

    TRAC is an advanced best-estimate computer code for analyzing postulated accidents in light water reactors. This paper gives a brief description of the code followed by comparisons of TRAC calculations with data from a variety of separate-effects, system-effects, and integral experiments. Based on these comparisons, the capabilities and limitations of the early versions of TRAC are evaluated

  14. What Is Social Comparison and How Should We Study It?

    Science.gov (United States)

    Wood, Joanne V.

    1996-01-01

    Examines frequently used measures and procedures in social comparison research. The question of whether a method truly captures social comparison requires a clear understanding of what social comparison is; hence a definition of social comparison is proposed, multiple ancillary processes in social comparison are identified, and definitional…

  15. The Language of Comparisons: Communicating about Percentages

    Directory of Open Access Journals (Sweden)

    Jessica Polito

    2014-01-01

    Full Text Available While comparisons between percentages or rates appear frequently in journalism and advertising, and are an essential component of quantitative writing, many students fail to understand precisely what percentages mean, and lack fluency with the language used for comparisons. After reviewing evidence demonstrating this weakness, this experience-based perspective lays out a framework for teaching the language of comparisons in a structured way, and illustrates it with several authentic examples that exemplify mistaken or misleading uses of such numbers. The framework includes three common types of erroneous or misleading quantitative writing: the missing comparison, where a key number is omitted; the apples-to-pineapples comparison, where two subtly incomparable rates are presented; and the implied fallacy, where an invalid quantitative conclusion is left to the reader to infer.

  16. The Current Status of Microscopical Hair Comparisons

    Directory of Open Access Journals (Sweden)

    Walter F. Rowe

    2001-01-01

    Full Text Available Although the microscopical comparison of human hairs has been accepted in courts of law for over a century, recent advances in DNA technology have called this type of forensic examination into question. In a number of cases, post-conviction DNA testing has exonerated defendants who were convicted in part on the results of microscopical hair comparisons. A federal judge has held a Daubert hearing on the microscopical comparison of human hairs and has concluded that this type of examination does not meet the criteria for admission of scientific evidence in federal courts. A review of the available scientific literature on microscopical hair comparisons (including studies conducted by the Royal Canadian Mounted Police and the Federal Bureau of Investigation leads to three conclusions: (1 microscopical comparisons of human hairs can yield scientifically defensible conclusions that can contribute to criminal investigations and criminal prosecutions, (2 the reliability of microscopical hair comparisons is strongly affected by the training of the forensic hair examiner, (3 forensic hair examiners cannot offer estimates of the probability of a match of a questioned hair with a hair from a randomly selected person. In order for microscopical hair examinations to survive challenges under the U.S. Supreme Court’s Daubert decision, hair microscopists must be better trained and undergo frequent proficiency testing. More research on the error rates of microscopical hair comparisons should be undertaken, and guidelines for the permissible interpretations of such comparisons should be established. Until these issues have been addressed and satisfactorily resolved, microscopical hair comparisons should be regarded by law enforcement agencies and courts of law as merely presumptive in nature, and all microscopical hair comparisons should be confirmed by nuclear DNA profiling or mitochondrial DNA sequencing.

  17. Zika detection: comparison of methodologies

    Directory of Open Access Journals (Sweden)

    Tatiana Elias Colombo

    Full Text Available ABSTRACT Many countries in the Americas have detected local transmission of multiple arboviruses that cause febrile illnesses. Therefore, laboratory testing has become an important tool for confirming the etiology of these diseases. The present study aimed to compare the sensitivity and specificity of three different Zika virus detection assays. One hundred serum samples from patients presenting with acute febrile symptoms were tested using a previously reported TaqMan® RT-qPCR assay. We used a SYBR® Green RT-qPCR and a conventional PCR methodologies to compare the results. Of the samples that were determined to be negative by the TaqMan® RT-qPCR assay, 100% (Kappa = 0.670 were also found to be negative by SYBR® Green RT-qPCR based on Tm comparison; however, 14% (Kappa = 0.035 were found to be positive by conventional PCR followed by agarose gel electrophoresis. The differences between the ZIKV strains circulating worldwide and the low viremia period can compromise diagnostic accuracy and thereby the accuracy of outbreak data. Therefore, improved assays are required to improve the diagnosis and surveillance of arbovirus.

  18. Distributed Wind Policy Comparison Tool

    Energy Technology Data Exchange (ETDEWEB)

    None

    2011-12-01

    Power through Policy: 'Best Practices' for Cost-Effective Distributed Wind is a U.S. Department of Energy (DOE)-funded project to identify distributed wind technology policy best practices and to help policymakers, utilities, advocates, and consumers examine their effectiveness using a pro forma model. Incorporating a customized feed from the Database of State Incentives for Renewables and Efficiency (DSIRE), the Web-based Distributed Wind Policy Comparison Tool (Policy Tool) is designed to assist state, local, and utility officials in understanding the financial impacts of different policy options to help reduce the cost of distributed wind technologies. The Policy Tool can be used to evaluate the ways that a variety of federal and state policies and incentives impact the economics of distributed wind (and subsequently its expected market growth). It also allows policymakers to determine the impact of policy options, addressing market challenges identified in the U.S. DOE’s '20% Wind Energy by 2030' report and helping to meet COE targets.

  19. [Comparison among families of Mutong].

    Science.gov (United States)

    Ma, Hong-mei; Zhang, Bo-li

    2002-06-01

    To distinguish families of Mutong correctly and direct effective and safe clinical administration. Comparison among families of Mutong on Herbs, Taxology, Clinic, Pharmacology and Toxicology. 1. There are mainly three families of Mutong: Lardizabalaceae, Ranunculaceae, Aristolochiaceae, which were all included in China Pharmacopeia in 1963. However only Mutong of Ranunculaceae and Aristolochiaceae family have been included in China Pharmacopeia since 1977, but Mutong of Lardizabalaceae family has not been included in China Pharmacopeia ever since. 2. It was Mutong of Lardizabalaceae family that was used mainly through the ages without toxic records, and Mutong of Aristolochiaceae e.g. Caulis Aristolochia manshuriensis (CAM) was not put down in writing of past ages but is mainly used today with toxicity repeatedly. 3. CAM contain aristolochic acid and aristololactam with high toxicity, which plays an uncertain role in diuresis with poor bactericidal power. Mutong of Lardizabalaceae family e.g. Akebia trifoliata (Thunb.) Koidz. var. australis (Diels) Rehd (ATKV) don't contain aristolochic acid and aristololactam, which has low toxicity and plays a certain role in diuresis with high bactericidal power. It may be quite safe to use ATKV instead of CAM in clinics. So we suggest that ATKV should be reused as first Mutong in China Pharmacopeia revised edition in order to ensure a correct understanding of the facts and reveal Mutong in its true colors, and CAM should be used as second Mutong strictly according to the rules in China Pharmacopeia revised edition.

  20. Construction contract revenue recording comparison

    Directory of Open Access Journals (Sweden)

    Hana Bohušová

    2008-01-01

    Full Text Available Publicly traded companies prepare their consolidated accounts in conformity with the international accounting standards (IAS/IFRS in accordance with the Regulation No. 1606/2002. This is obliged for all publicly traded joint-stock companies in the Czech Republic. Other companies prepare financial statements in accordance with national accounting standards. There are Accounting Act No. 563/1991 of Coll. and Regulation No. 500/2002 of Coll., Czech Accounting Standards in the Czech Republic. Both systems are based on different principles so there are many differences. The Czech Accounting System (CAS is based on the rules while IAS/IFRS are based on principles (Kovanicová, 2005. These differences are mainly caused by the different philosophy. CAS prefers the fiscal policy to the economic substance while IAS/IFRS prefere the economic substance. One of the most significant dif­fe­ren­ces is in the field of revenue recording. There are two standards concerning the revenues recording (IAS 18 − Revenue, IAS 11 – Construction Contracts in IAS/IFRS. CAS 019 – Expenses and Revenue are dealing with the revenue recording in the Czech Republic. The paper is aimed at the comparison of the methodical approaches for revenue recording used by IAS/IFRS and by CAS. The most important differences are caused by the different approach to the long term contracts (construction contracts, software development contracts revenues recording.

  1. Attractor comparisons based on density

    International Nuclear Information System (INIS)

    Carroll, T. L.

    2015-01-01

    Recognizing a chaotic attractor can be seen as a problem in pattern recognition. Some feature vector must be extracted from the attractor and used to compare to other attractors. The field of machine learning has many methods for extracting feature vectors, including clustering methods, decision trees, support vector machines, and many others. In this work, feature vectors are created by representing the attractor as a density in phase space and creating polynomials based on this density. Density is useful in itself because it is a one dimensional function of phase space position, but representing an attractor as a density is also a way to reduce the size of a large data set before analyzing it with graph theory methods, which can be computationally intensive. The density computation in this paper is also fast to execute. In this paper, as a demonstration of the usefulness of density, the density is used directly to construct phase space polynomials for comparing attractors. Comparisons between attractors could be useful for tracking changes in an experiment when the underlying equations are too complicated for vector field modeling

  2. Inferior or superior : socials comparison in Dutch and Spanish organizations

    NARCIS (Netherlands)

    Carmona Rodriguez, Carmen

    2006-01-01

    SUMMARY Social comparison is an automatic and daily process through which individuals acquire information about themselves. Since Festinger (1954) postulated his assumptions on social comparison, extensive research has focused on understanding and explaining the social comparison process. In

  3. Symbolic comparisons of objects on color attributes.

    Science.gov (United States)

    Paivio, A; te Linde, J

    1980-11-01

    Symbolic comparisons of object brightness and color were investigated in two experiments using words and outline drawings as stimuli. Both experiments yielded orderly symbolic distance effects. Contrary to prediction, no reliable picture advantages emerged. For color comparison, individual differences in word fluency and color memory predicted decision time with word stimuli. These results contrast sharply with those of previous comparison studies involving concrete dimensions. The results are discussed in terms of dual-coding theory and the role of verbal mechanisms in memory for object color.

  4. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo; Larsen, Erik

    The ‘CIA-CT comparison - Inter laboratory comparison on industrial Computed Tomography” is organized by DTU Department of Mechanical Engineering within the Danish project “Centre for Industrial Application of CT scanning - CIA-CT”. The project is co-financed by the Danish Ministry of Science......, Technology and Innovation. The comparison aims to collect information about measurement performance in state-of the-art industrial CT (Computed Tomography) scanning. Since CT scanning has entered the field of manufacturing and coordinate metrology, evaluation of uncertainty of measurement with assessment...

  5. An ecological momentary assessment of comparison target as a moderator of the effects of appearance-focused social comparisons.

    Science.gov (United States)

    Leahey, Tricia M; Crowther, Janis H

    2008-09-01

    This research examined whether comparison target moderates the effects of naturally occurring appearance-focused social comparisons on women's affect, appearance esteem, and dieting thoughts. During daily activities, body-satisfied (BS) women and body-dissatisfied (BD) women recorded their comparison targets and reactions to comparison information. For BS women, upward comparisons with peers were associated with more positive affect (PA) and appearance esteem and less guilt than upward comparisons with media images and downward comparisons with peers were associated with less PA than downward comparisons with media images. For BD women, upward comparisons with peers were associated with more appearance esteem and diet thoughts than upward comparisons with media images and downward comparisons with peers were associated with less PA, appearance esteem, and diet thoughts and more guilt than downward comparisons with media images.

  6. UAV PHOTOGRAMMETRY: BLOCK TRIANGULATION COMPARISONS

    Directory of Open Access Journals (Sweden)

    R. Gini

    2013-08-01

    Full Text Available UAVs systems represent a flexible technology able to collect a big amount of high resolution information, both for metric and interpretation uses. In the frame of experimental tests carried out at Dept. ICA of Politecnico di Milano to validate vector-sensor systems and to assess metric accuracies of images acquired by UAVs, a block of photos taken by a fixed wing system is triangulated with several software. The test field is a rural area included in an Italian Park ("Parco Adda Nord", useful to study flight and imagery performances on buildings, roads, cultivated and uncultivated vegetation. The UAV SenseFly, equipped with a camera Canon Ixus 220HS, flew autonomously over the area at a height of 130 m yielding a block of 49 images divided in 5 strips. Sixteen pre-signalized Ground Control Points, surveyed in the area through GPS (NRTK survey, allowed the referencing of the block and accuracy analyses. Approximate values for exterior orientation parameters (positions and attitudes were recorded by the flight control system. The block was processed with several software: Erdas-LPS, EyeDEA (Univ. of Parma, Agisoft Photoscan, Pix4UAV, in assisted or automatic way. Results comparisons are given in terms of differences among digital surface models, differences in orientation parameters and accuracies, when available. Moreover, image and ground point coordinates obtained by the various software were independently used as initial values in a comparative adjustment made by scientific in-house software, which can apply constraints to evaluate the effectiveness of different methods of point extraction and accuracies on ground check points.

  7. Comparison of Vehicle Choice Models

    Energy Technology Data Exchange (ETDEWEB)

    Stephens, Thomas S. [Argonne National Lab. (ANL), Argonne, IL (United States); Levinson, Rebecca S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brooker, Aaron [National Renewable Energy Lab. (NREL), Golden, CO (United States); Liu, Changzheng [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lin, Zhenhong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Birky, Alicia [Energetics Incorporated, Columbia, MD (United States); Kontou, Eleftheria [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-10-31

    Five consumer vehicle choice models that give projections of future sales shares of light-duty vehicles were compared by running each model using the same inputs, where possible, for two scenarios. The five models compared — LVCFlex, MA3T, LAVE-Trans, ParaChoice, and ADOPT — have been used in support of the Energy Efficiency and Renewable Energy (EERE) Vehicle Technologies Office in analyses of future light-duty vehicle markets under different assumptions about future vehicle technologies and market conditions. The models give projections of sales shares by powertrain technology. Projections made using common, but not identical, inputs showed qualitative agreement, with the exception of ADOPT. ADOPT estimated somewhat lower advanced vehicle shares, mostly composed of hybrid electric vehicles. Other models projected large shares of multiple advanced vehicle powertrains. Projections of models differed in significant ways, including how different technologies penetrated cars and light trucks. Since the models are constructed differently and take different inputs, not all inputs were identical, but were the same or very similar where possible. Projections by all models were in close agreement only in the first few years. Although the projections from LVCFlex, MA3T, LAVE-Trans, and ParaChoice were in qualitative agreement, there were significant differences in sales shares given by the different models for individual powertrain types, particularly in later years (2030 and later). For example, projected sales shares of conventional spark-ignition vehicles in 2030 for a given scenario ranged from 35% to 74%. Reasons for such differences are discussed, recognizing that these models were not developed to give quantitatively accurate predictions of future sales shares, but to represent vehicles markets realistically and capture the connections between sales and important influences. Model features were also compared at a high level, and suggestions for further comparison

  8. Micro Foundations for International Productivity Comparisons

    NARCIS (Netherlands)

    Gersbach, Hans; Ark, Bart van

    1994-01-01

    This paper describes the methodology and procedures of international comparisons of productivity levels for twelve manufacturing industries (producing food products, beer, soap and detergents, iron and steel, machine tools, various types of machinery, computers, audio and video equipment, industrial

  9. Comparison between KARBUS and APOLLO 1

    International Nuclear Information System (INIS)

    Payer, L.; Broeders, C.

    1995-01-01

    A comparison is made between benchmark calculations by the French APOLLO 1 code and the Karlsruhe KARBUS procedure. Independently these two codes had been developed for transport computations in infinite reactor configurations and for burnup calculations. (orig.)

  10. Brain connectivity measures: computation and comparison

    Directory of Open Access Journals (Sweden)

    Jovanović Aleksandar

    2013-12-01

    Full Text Available In this article computation and comparison of causality measures which are used in determination of brain connectivity patterns is investigated. Main analyzed examples included published computation and comparisons of Directed Transfer Function ‐ DTF and Partial Directed Coherence ‐ PDC. It proved that serious methodology mistakes were involved in measure computations and comparisons. It is shown that the neighborhood of zero is of accented importance in such evaluations and that the issues of semantic stability have to be treated with more attention. Published results on the relationship of these two important measures are partly unstable with small changes of zero threshold and pictures of involved brain structures deduced from the cited articles have to be corrected. Analysis of the operators involved in evaluation and comparisons is given with suggestions for their improvement and complementary additional actions.

  11. Comparison Of Clinical, Parasitological And Serological Diagnostic ...

    African Journals Online (AJOL)

    Comparison Of Clinical, Parasitological And Serological Diagnostic Methods For The Definitive ... Consideringthe relative significance of these methods in the diagnosis of onchocerciasis, we ... http://dx.doi.org/10.4314/ari.v1i3.40835.

  12. Doctoral Program Selection Using Pairwise Comparisons.

    Science.gov (United States)

    Tadisina, Suresh K.; Bhasin, Vijay

    1989-01-01

    The application of a pairwise comparison methodology (Saaty's Analytic Hierarchy Process) to the doctoral program selection process is illustrated. A hierarchy for structuring and facilitating the doctoral program selection decision is described. (Author/MLW)

  13. Quantum-state comparison and discrimination

    Science.gov (United States)

    Hayashi, A.; Hashimoto, T.; Horibe, M.

    2018-05-01

    We investigate the performance of discrimination strategy in the comparison task of known quantum states. In the discrimination strategy, one infers whether or not two quantum systems are in the same state on the basis of the outcomes of separate discrimination measurements on each system. In some cases with more than two possible states, the optimal strategy in minimum-error comparison is that one should infer the two systems are in different states without any measurement, implying that the discrimination strategy performs worse than the trivial "no-measurement" strategy. We present a sufficient condition for this phenomenon to happen. For two pure states with equal prior probabilities, we determine the optimal comparison success probability with an error margin, which interpolates the minimum-error and unambiguous comparison. We find that the discrimination strategy is not optimal except for the minimum-error case.

  14. Acute ischemic stroke prognostication, comparison between ...

    African Journals Online (AJOL)

    Ossama Y. Mansour

    2014-11-20

    Nov 20, 2014 ... patients with acute ischemic stroke in comparison with the NIHSS and the GCS. Methods: .... All patients received a CT scan of the brain on admission. Diagnostic ... adjusted for age, sex, Charlson Index and Oxfordshire. 248.

  15. Synthesis, characterization and comparison of polythiophene ...

    Indian Academy of Sciences (India)

    38

    Synthesis, characterization and comparison of polythiophene-carbon ... b Nanotechnology Research Institute, School of Chemical Engineering, Babol University of Technology, Babol, ..... The scan range was from −0.24 to 1.2 V in reference to.

  16. Medicare Managed Care plan Performance, A Comparison...

    Data.gov (United States)

    U.S. Department of Health & Human Services — The study evaluates the performance of Medicare managed care, Medicare Advantage, Plans in comparison to Medicare fee-for-service Plans in three states with...

  17. Comparison of GLONASS and GPS Time Transfers

    Science.gov (United States)

    Daly, P.; Koshelyaevsky, N. B.; Lewandowski, W.; Petit, G.; Thomas, C.

    1993-01-01

    The Russian global space navigation system GLONASS could provide a technique similar to GPS for international time comparison. The main limitation to its use for time transfer is the lack of commercially available time receivers. The University of Leeds built a GPS/GLONASS receiver five years ago and since then has provided continuous information about GLONASS time and its comparison with GPS time. For the last two years the VNIIFTRI and several other Russian time laboratories have used Russian-built GLONASS navigation receivers for time comparisons. Since June 1991, the VNIIFTRI has operated a GPS time receiver which offers, for the first time, an opportunity for the direct comparison of time transfers using GPS and GLONASS. This seven-month experiment shows that even with relatively imprecise data recording and processing, in terms of time metrology, GLONASS can provide continental time transfer at a level of several tens of nanoseconds.

  18. Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Qianjun, E-mail: jiaqianjun@126.com [Southern Medical University, Guangzhou, Guangdong (China); Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Zhuang, Jian, E-mail: zhuangjian5413@tom.com [Department of Cardiac Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Jiang, Jun, E-mail: 81711587@qq.com [Department of Radiology, Shenzhen Second People’s Hospital, Shenzhen, Guangdong (China); Li, Jiahua, E-mail: 970872804@qq.com [Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Huang, Meiping, E-mail: huangmeiping_vip@163.com [Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Southern Medical University, Guangzhou, Guangdong (China); Liang, Changhong, E-mail: cjr.lchh@vip.163.com [Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Southern Medical University, Guangzhou, Guangdong (China)

    2017-01-15

    Purpose: To compare the image quality, rate of coronary artery visualization and diagnostic accuracy of 256-slice multi-detector computed tomography angiography (CTA) with prospective electrocardiographic (ECG) triggering at a tube voltage of 80 kVp between 3 reconstruction algorithms (filtered back projection (FBP), hybrid iterative reconstruction (iDose{sup 4}) and iterative model reconstruction (IMR)) in infants with congenital heart disease (CHD). Methods: Fifty-one infants with CHD who underwent cardiac CTA in our institution between December 2014 and March 2015 were included. The effective radiation doses were calculated. Imaging data were reconstructed using the FBP, iDose{sup 4} and IMR algorithms. Parameters of objective image quality (noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)); subjective image quality (overall image quality, image noise and margin sharpness); coronary artery visibility; and diagnostic accuracy for the three algorithms were measured and compared. Results: The mean effective radiation dose was 0.61 ± 0.32 mSv. Compared to FBP and iDose{sup 4}, IMR yielded significantly lower noise (P < 0.01), higher SNR and CNR values (P < 0.01), and a greater subjective image quality score (P < 0.01). The total number of coronary segments visualized was significantly higher for both iDose{sup 4} and IMR than for FBP (P = 0.002 and P = 0.025, respectively), but there was no significant difference in this parameter between iDose{sup 4} and IMR (P = 0.397). There was no significant difference in the diagnostic accuracy between the FBP, iDose{sup 4} and IMR algorithms (χ{sup 2} = 0.343, P = 0.842). Conclusions: For infants with CHD undergoing cardiac CTA, the IMR reconstruction algorithm provided significantly increased objective and subjective image quality compared with the FBP and iDose{sup 4} algorithms. However, IMR did not improve the diagnostic accuracy or coronary artery visualization compared with iDose{sup 4}.

  19. Comparison of SAND-II and FERRET

    International Nuclear Information System (INIS)

    Wootan, D.W.; Schmittroth, F.

    1981-01-01

    A comparison was made of the advantages and disadvantages of two codes, SAND-II and FERRET, for determining the neutron flux spectrum and uncertainty from experimental dosimeter measurements as anticipated in the FFTF Reactor Characterization Program. This comparison involved an examination of the methodology and the operational performance of each code. The merits of each code were identified with respect to theoretical basis, directness of method, solution uniqueness, subjective influences, and sensitivity to various input parameters

  20. Comparison of physical fitness tests in swimming

    OpenAIRE

    Dostálová, Sabina

    2015-01-01

    Title: Comparison of physical fitness tests in swimming. Objective: The aim of this thesis is to evaluate specific tests, used while testing selected physical abilities in swimming. By specific tests we mean tests realized in the water. Selected tests are intended for swim coaches, who train junior to senior age groups. Methods: The chosen method was a comparison of studies, that pursue selected specific tests. We created partial conclusions for every test by summing up the results of differe...

  1. Nuclear medical examinations in Marfan's syndrome

    International Nuclear Information System (INIS)

    D'haene, E.G.M.

    1985-01-01

    Four patients of one family with the Marfan's syndrome have been examined with nuclear medical techniques. A combination of isotopes, angiography and ECG triggered bloodpoolscintigraphy with echocardiography are very suitable to examine the course of the disease. (Auth.)

  2. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

    NARCIS (Netherlands)

    W. Tanis (Wilco); R.P.J. Budde (Ricardo); I.A.C. van der Bilt (Ivo); B. Delemarre; G. Hoohenker; J.-K. Van Rooden; A.M. Scholtens (Asbjørn M.); J. Habets; S.A.J. Chamuleau (Steven)

    2016-01-01

    textabstractProsthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission

  3. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

    NARCIS (Netherlands)

    Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S

    Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including

  4. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  5. Feasibility and outcomes of atrial fibrillation screening using intermittent electrocardiography in a primary healthcare setting: A cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Faris Ghazal

    Full Text Available Atrial fibrillation (AF is a major risk factor for ischemic stroke unless treated with an anticoagulant. Detecting AF can be difficult because AF is often paroxysmal and asymptomatic. The aims of this study were to develop a screening model to detect AF in a primary healthcare setting and to initiate oral anticoagulant therapy in high-risk patients to prevent stroke.This was a cross-sectional study. All 70- to 74-year-old individuals registered at a single primary healthcare center in Stockholm were invited to participate in AF screening upon visiting the center during a ten-month period. Those who did not have contact with the center during this period were invited to participate by letter. Thirty-second intermittent ECG recordings were made twice a day using a handheld Zenicor device over a 2-week period in participants without AF. Oral anticoagulant therapy was offered to patients with newly detected AF.Of the 415 eligible individuals, a total of 324 (78.1% patients participated in the study. The mean age of the participants was 72 years, 52.2% were female, and the median CHA2DS2-VASc score of the participants was 3. In the target population, 34 (8.2% individuals had previously diagnosed AF. Among participants without previously known AF, 16 (5.5% cases of AF were detected. The final AF prevalence in the target population was 12%. Oral anticoagulant therapy was successfully initiated in 88% of these patients with newly detected AF.The AF screening project exhibited a high participation rate and resulted in a high rate of newly discovered AF; of these newly diagnosed patients, 88% could be treated with an oral anticoagulant.

  6. Clinical role of electrocardiography and of 201Tl scintigraphy exercise tests in diagnosis of ischemic heart disease

    International Nuclear Information System (INIS)

    Jelok, I.; Hatala, R.; Mistrik, A.; Borovicova, F.

    1988-01-01

    The diagnostic potential of ECG and scintigraphy exercise tests is assessed in the light of the experience gained by the authors in the detection of ischemic heart disease, and the complementary character of the two methods is emphasized. The rational and differentiated use of the two noninvasive examination methods requires an optimal clinical assessment of the patient's condition with regard to the probable incidence of the disease. Optimal diagnostic benefit (as compared with the ECG exercise test up to 32%) is shown of scintigraphy, especially in persons with multiple risk factors and atypical chest pain. With regard to the unavailability of perfusion scintigraphy of the myocardium in the authors' clinical practice, they recommend that this examination should mainly be indicated for patients who have a negative or uniterpretable ECG exercise test. (author). 1 tab., 13 refs

  7. Feasibility and accuracy of a new mobile electrocardiography device, ER-2000®, in the diagnosis of arrhythmia

    Directory of Open Access Journals (Sweden)

    Yae Min Park

    2015-08-01

    Conclusions: A rhythm strip obtained using ER-2000® is accurate in diagnosing arrhythmia, despite some differences in the detailed morphology of the QRS and T-wave, and the pacing spike compared to those obtained by the 12-lead ECG.

  8. Coronary artery anomalies: Assessment with electrocardiography-gate multidetector-row CT at a single center in Korea

    International Nuclear Information System (INIS)

    Yi, Bo Ram; Sun, Joo Sung; Yang, Hyoung Mo; Kang, Doo Kyoung

    2015-01-01

    To determine the prevalence of coronary anomalies using coronary computed tomography angiography (CCTA) and to evaluate the relationship between coronary artery anomalies and chest pain. A total of 12676 patients underwent CCTA scans at our institution between December 2006 and April 2013 using a 64-slice CT and a 128-slice dual-source CT. We determined the prevalence of coronary artery anomalies according to the classification system proposed by Greenberg. The presence or absence of chest pain with each coronary artery anomaly was also evaluated. Coronary anomalies were found in 176 patients (1.39%) at our institute. Anomalies of origination, course, and termination were detected in 118 (0.93%), 28 (0.22%), and 30 (0.24%) patients, respectively. After the exclusion of 32 patients with combined heart disease, typical (n = 16; 11.1%) or atypical (n = 28; 19.4%) chest pain was present in 44 (30.6%) of the 144 patients at the time of diagnosis. The prevalence of coronary artery anomalies was 1.39% at our hospital. After the exclusion of patients with combined heart disease, 11.1% had typical chest pain at the time of diagnosis.

  9. A stretchable electrode array for non-invasive, skin-mounted measurement of electrocardiography (ECG), electromyography (EMG) and electroencephalography (EEG).

    Science.gov (United States)

    Ma, Rui; Kim, Dae-Hyeong; McCormick, Martin; Coleman, Todd; Rogers, John

    2010-01-01

    This paper reports a class of stretchable electrode array capable of intimate, conformal integration onto the curvilinear surfaces of skin on the human body. The designs employ conventional metallic conductors but in optimized mechanical layouts, on soft, thin elastomeric substrates. These devices exhibit an ability to record spontaneous EEG activity even without conductive electrolyte gels, with recorded alpha rhythm responses that are 40% stronger than those collected using conventional tin electrodes and gels under otherwise similar conditions. The same type of device can also measure high quality ECG and EMG signals. The results suggest broad utility for skin-mounted measurements of electrical activity in the body, with advantages in signal levels, wearability and modes of integration compared to alternatives.

  10. 24-HOUR ELECTROCARDIOGRAPHY IN CLINICAL HEALTHY CAVALIER KING CHARLES SPANIELS, WIRE-HAIRED DACHSHUNDS AND CAIRN TERRIERS

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Vesterholm, Stina; Ludvigsen, Trine Pagh

    2010-01-01

    analysis were analyzed for influence by breed, age, gender, relevant heart rate (HR) parameters and bodyweight. CKCS had a significantly higher HRex (mean 121 ± SD 12 bpm) compared to wD (94±18 bpm) (P>0.0001) and CT (102±16bpm) (P=0.0009). The minimum HR (HRmin) measured during Holter recording...... was significantly higher in CKCS (51±10 bpm) compared to wD (42±7 bpm) (P=0.001) and CT (45±7 bpm) (P=0.05). In addition, CKCS had a higher mean HR (HRmean) during Holter recording (83±13 bpm) compared to wD (68±8 bpm) (P>0.0001) and CT (75±10 bpm) (P=0.04). Both HRmean (P>0.0001) and HRmin (P=0.001) were...

  11. ECG Wave-Maven: An Internet-based Electrocardiography Self-Assessment Program for Students and Clinicians

    Directory of Open Access Journals (Sweden)

    Ary L. Goldberger

    2003-02-01

    Full Text Available Purpose: To create a multimedia internet-based ECG teaching tool, with the ability to rapidly incorporate new clinical cases. Method: We created ECG Wave-Maven (http://ecg.bidmc.harvard.edu, a novel teaching tool with a direct link to an institution-wide clinical repository. We analyzed usage data from the web between December, 2000 and May 2002. Results: In 17 months, there have been 4105 distinct uses of the program. A majority of users are physicians or medical students (2605, 63%, and almost half report use as an educational tool. Conclusions: The internet offers an opportunity to provide easily-expandable, open access resources for ECG pedagogy which may be used to complement traditional methods of instruction

  12. ECG Wave-Maven: An Internet-based Electrocardiography Self-Assessment Program for Students and Clinicians.

    Science.gov (United States)

    McClennen, Seth; Nathanson, Larry A; Safran, Charles; Goldberger, Ary L

    2003-12-01

    To create a multimedia internet-based ECG teaching tool, with the ability to rapidly incorporate new clinical cases. We created ECG Wave-Maven ( http://ecg.bidmc.harvard.edu ), a novel teaching tool with a direct link to an institution-wide clinical repository. We analyzed usage data from the web between December, 2000 and May 2002. In 17 months, there have been 4105 distinct uses of the program. A majority of users are physicians or medical students (2605, 63%), and almost half report use as an educational tool. The internet offers an opportunity to provide easily-expandable, open access resources for ECG pedagogy which may be used to complement traditional methods of instruction.

  13. Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease

    Science.gov (United States)

    Schlegel, Todd T.; Kulecz, Walter B.; DePalma, Jude L.; Feiveson, Alan H.; Wilson, John S.; Rahman, M. Atiar; Bungo, Michael W.

    2004-01-01

    Several studies have shown that diminution of the high-frequency (HF; 150-250 Hz) components present within the central portion of the QRS complex of an electrocardiogram (ECG) is a more sensitive indicator for the presence of myocardial ischemia than are changes in the ST segments of the conventional low-frequency ECG. However, until now, no device has been capable of displaying, in real time on a beat-to-beat basis, changes in these HF QRS ECG components in a continuously monitored patient. Although several software programs have been designed to acquire the HF components over the entire QRS interval, such programs have involved laborious off-line calculations and postprocessing, limiting their clinical utility. We describe a personal computer-based ECG software program developed recently at the National Aeronautics and Space Administration (NASA) that acquires, analyzes, and displays HF QRS components in each of the 12 conventional ECG leads in real time. The system also updates these signals and their related derived parameters in real time on a beat-to-beat basis for any chosen monitoring period and simultaneously displays the diagnostic information from the conventional (low-frequency) 12-lead ECG. The real-time NASA HF QRS ECG software is being evaluated currently in multiple clinical settings in North America. We describe its potential usefulness in the diagnosis of myocardial ischemia and coronary artery disease.

  14. The role of comparison motives in the relationship between personality and comparison level choice

    NARCIS (Netherlands)

    Eggens, L.; Hendriks, A. A. J.; Bosker, R. J.; van der Werf, M. P. C.

    2011-01-01

    This article studied whether the motives for comparison of grades with those of others play a mediating role in the relationship between the Big Five personality traits and the choice of the level of comparison of students. The study was conducted among about 1,500 students in higher education. Of

  15. Is Comparison the Thief of Joy? Sexual Narcissism and Social Comparisons in the Domain of Sexuality.

    Science.gov (United States)

    Day, Lisa C; Muise, Amy; Impett, Emily A

    2017-02-01

    Are people who are high in sexual narcissism more sensitive to information comparing their sex lives with the sex lives of others? Does this sensitivity explain narcissists' lower sexual and relationship satisfaction? We conducted three studies to address this question. Participants completed the Sexual Narcissism Scale (Widman & McNulty, 2010), and then either recalled (Study 1), imagined (Study 2), or actually made (Study 3) a sexual comparison. We found that people high in sexual narcissism (compared with those lower in sexual narcissism) were more bothered when comparing themselves with someone with a higher sexual frequency and felt better about a comparison with someone with a lower sexual frequency. In turn, narcissists' greater sensitivity to upward social comparisons predicted lower sexual and relationship satisfaction. These results suggest that those high in sexual narcissism may use downward sexual comparisons to maintain their grandiose self-views and be particularly sensitive to upward sexual comparisons.

  16. Comparison of Tritium Component Failure Rate Data

    International Nuclear Information System (INIS)

    Lee C. Cadwallader

    2004-01-01

    Published failure rate values from the US Tritium Systems Test Assembly, the Japanese Tritium Process Laboratory, the German Tritium Laboratory Karlsruhe, and the Joint European Torus Active Gas Handling System have been compared. This comparison is on a limited set of components, but there is a good variety of data sets in the comparison. The data compared reasonably well. The most reasonable failure rate values are recommended for use on next generation tritium handling system components, such as those in the tritium plant systems for the International Thermonuclear Experimental Reactor and the tritium fuel systems of inertial fusion facilities, such as the US National Ignition Facility. These data and the comparison results are also shared with the International Energy Agency cooperative task on fusion component failure rate data

  17. Active Metric Learning from Relative Comparisons

    OpenAIRE

    Xiong, Sicheng; Rosales, Rómer; Pei, Yuanli; Fern, Xiaoli Z.

    2014-01-01

    This work focuses on active learning of distance metrics from relative comparison information. A relative comparison specifies, for a data point triplet $(x_i,x_j,x_k)$, that instance $x_i$ is more similar to $x_j$ than to $x_k$. Such constraints, when available, have been shown to be useful toward defining appropriate distance metrics. In real-world applications, acquiring constraints often require considerable human effort. This motivates us to study how to select and query the most useful ...

  18. A comparison of goniophotometric measurement facilities

    DEFF Research Database (Denmark)

    Thorseth, Anders; Lindén, Johannes; Dam-Hansen, Carsten

    2016-01-01

    In this paper, we present the preliminary results of a comparison between widely different goniophotometric and goniospectroradiometric measurement facilities. The objective of the comparison is to increase consistency and clarify the capabilities among Danish test laboratories. The study will seek...... to find the degree of equivalence between the various facilities and methods. The collected data is compared by using a three-way variation of principal component analysis, which is well suited for modelling large sets of correlated data. This method drastically decreases the number of numerical values...

  19. Assertiveness, submissive behaviour and social comparison.

    Science.gov (United States)

    Gilbert, P; Allan, S

    1994-09-01

    This paper explores the relationship between a new assertiveness measure (the Scale for Interpersonal Behaviour--SIB), social comparison and submissive behaviour. The paper investigates these measures in relation to the personality traits of neuroticism and introversion. Findings suggest: (a) that social comparison may be an important variable in assertiveness and submissive behaviour and shows a strong relationship to neuroticism and introversion; (b) that submissive behaviour is not the mirror opposite of assertive behaviour; and (c) submissive behaviour seems more strongly associated with introversion and neuroticism than assertive performance.

  20. Ranking health between countries in international comparisons

    DEFF Research Database (Denmark)

    Brønnum-Hansen, Henrik

    2014-01-01

    Cross-national comparisons and ranking of summary measures of population health sometimes give rise to inconsistent and diverging conclusions. In order to minimise confusion, international comparative studies ought to be based on well-harmonised data with common standards of definitions and docum......Cross-national comparisons and ranking of summary measures of population health sometimes give rise to inconsistent and diverging conclusions. In order to minimise confusion, international comparative studies ought to be based on well-harmonised data with common standards of definitions...

  1. CCD Photometry Using Multiple Comparison Stars

    Directory of Open Access Journals (Sweden)

    Yonggi Kim

    2004-09-01

    Full Text Available The accuracy of CCD observations obtained at the Korean 1.8 m telescope has been studied. Seventeen comparison stars in the vicinity of the cataclysmic variable BG CMi have been measured. The ``artificial" star has been used instead of the ``control" star, what made possible to increase accuracy estimates by a factor of 1.3-2.1 times for ``good" and ``cloudy" nights, respectively. The algorithm of iterative determination of accuracy and weights of few comparison stars contributing to the artificial star, has been presented. The accuracy estimates for 13-mag stars are around 0.002 m mag for exposure times of 30 sec.

  2. Comparison of left and right ventricular volume measurement using the Simpson's method and the area length method

    International Nuclear Information System (INIS)

    Hergan, Klaus; Schuster, Antonius; Fruehwald, Julia; Mair, Michael; Burger, Ralph; Toepker, Michael

    2008-01-01

    Purpose: To compare ventricular volume measurement using a volumetric approach in the three standard cardiac planes and ventricular volume estimation by a geometrical model, the Area-Length method (ALM). Materials and methods: Fifty-six healthy volunteers were examined (27 males, 29 females) on a 1.5 T MR-unit with ECG-triggered steady state free precision (SSFP) Cine-MR sequences and parallel image acquisition. Multiple slices in standardized planes including the short-axis view (sa), 4-chamber view (4ch), left and right 2-chamber views (2ch) were used to cover the whole heart. End-systolic and end-diastolic ventricular volumes (EDV, ESV), stroke volume (SV), and ejection fraction (EF) were calculated with Simpson's rule in all planes and with ALM in the 2ch and 4ch planes. Global function parameters measured in the sa plane were compared with those obtained in the other imaging planes. Results: A very good correlation is observed when comparing functional parameters calculated with Simpson's rule in all imaging planes: for instance, the mean EDV/ESV of the left and right ventricle of the female population group measured in sa, 4ch, and 2ch: left ventricle EDV/ESV 114.3/44.4, 120.9/46.5, and 117.7/45.3 ml; right ventricle EDV/ESV 106.6/46.0, 101.2/41.1, and 103.5/43.0 ml. Functional parameters of the left ventricle calculated with ALM in 2ch and 4ch correlate to parameters obtained in sa with Simpson's rule in the range of 5-10%: for instance, the EDV/ESV of the left ventricle of the male population group measured in the sa, 4ch, and 2ch: 160.3/63.5, 163.1/59.0, and 167.0/65.7 ml. Functional parameters of the right ventricle measured with ALM in 4ch are 40-50% lower and calculated in 2ch almost double as high as compared with the parameters obtained in sa with Simpson's rule: for instance, male right ventricular EDV/ESV measured in sa, 4ch, and 2ch: 153.4/68.1, 97.5/34.5, and 280.2/123.2 ml. The EF correlates for all imaging planes measured with the Simpson's rule

  3. Immediacy bias in social-emotional comparisons.

    Science.gov (United States)

    White, Katherine; Van Boven, Leaf

    2012-08-01

    In seven studies of naturally occurring, "real-world" emotional events, people demonstrated an immediacy bias in social-emotional comparisons, perceiving their own current or recent emotional reactions as more intense compared with others' emotional reactions to the same events. The events examined include crossing a scary bridge (study 1a), a national tragedy (study 1b), terrorist attacks (studies 2a and 3b), a natural disaster (study 2b), and a presidential election (study 3b). These perceived differences between one's own and others' emotions declined over time, as relatively immediate and recent emotions subsided, a pattern that people were not intuitively aware of (study 2c). This immediacy bias in social-emotional comparisons emerged for both explicit comparisons (studies 1a, 1b, and 3b), and for absolute judgments of emotional intensity (studies 2a, 2b, and 3a). Finally, the immediacy bias in social-emotional comparisons was reduced when people were reminded that emotional display norms might lead others' appearances to understate emotional intensity (studies 3a and 3b). Implications of these findings for social-emotional phenomena are discussed.

  4. Comparison of neutron spectrum unfolding codes

    International Nuclear Information System (INIS)

    Zijp, W.

    1979-02-01

    This final report contains a set of four ECN-reports. The first is dealing with the comparison of the neutron spectrum unfolding codes CRYSTAL BALL, RFSP-JUL, SAND II and STAY'SL. The other three present the results of calculations about the influence of statistical weights in CRYSTAL BALL, SAND II and RFSP-JUL

  5. Transports and the environment: European comparisons

    International Nuclear Information System (INIS)

    2009-01-01

    For different issues (freight transport, passenger transport, greenhouse gas emissions, air pollution, fuel consumption in transport and energy efficiency), and illustrated by data tables and figures, this report proposes assessments and comments of the impact on the environment, an overview of the French situation, a comparison with European countries, and an analysis of French peculiarities

  6. Ordinal Welfare Comparisons with Multiple Discrete Indicators

    DEFF Research Database (Denmark)

    Arndt, Channing; Distante, Roberta; Hussain, M. Azhar

    We develop an ordinal method for making welfare comparisons between populations with multidimensional discrete well-being indicators observed at the micro level. The approach assumes that, for each well-being indicator, the levels can be ranked from worse to better; however, no assumptions are made...

  7. A photon dominated region code comparison study

    NARCIS (Netherlands)

    Roellig, M.; Abel, N. P.; Bell, T.; Bensch, F.; Black, J.; Ferland, G. J.; Jonkheid, B.; Kamp, I.; Kaufman, M. J.; Le Bourlot, J.; Le Petit, F.; Meijerink, R.; Morata, O.; Ossenkopf, Volker; Roueff, E.; Shaw, G.; Spaans, M.; Sternberg, A.; Stutzki, J.; Thi, W.-F.; van Dishoeck, E. F.; van Hoof, P. A. M.; Viti, S.; Wolfire, M. G.

    Aims. We present a comparison between independent computer codes, modeling the physics and chemistry of interstellar photon dominated regions (PDRs). Our goal was to understand the mutual differences in the PDR codes and their effects on the physical and chemical structure of the model clouds, and

  8. New directions in social comparison research

    NARCIS (Netherlands)

    Buunk, Abraham (Bram); Mussweiler, T

    2001-01-01

    This article notices that social comparison theory has developed from being a focused theoretical statement on the use of others for self-evaluation into a lively and varied area of research encompassing many different paradigms, approaches and applications. A recent 'renaissance' in social

  9. Comparison of community managed projects and conventional ...

    African Journals Online (AJOL)

    Comparison of community managed projects and conventional approaches in rural water supply of Ethiopia. ... African Journal of Environmental Science and Technology ... This study aimed to compare Community Managed Projects (CMP) approach with the conventional approaches (Non-CMP) in the case of Ethiopia.

  10. Model comparisons and genetic and environmental parameter ...

    African Journals Online (AJOL)

    arc

    Model comparisons and genetic and environmental parameter estimates of growth and the ... breeding strategies and for accurate breeding value estimation. The objectives ...... Sci. 23, 72-76. Van Wyk, J.B., Fair, M.D. & Cloete, S.W.P., 2003.

  11. Privacy Preserving Mapping Schemes Supporting Comparison

    NARCIS (Netherlands)

    Tang, Qiang

    2010-01-01

    To cater to the privacy requirements in cloud computing, we introduce a new primitive, namely Privacy Preserving Mapping (PPM) schemes supporting comparison. An PPM scheme enables a user to map data items into images in such a way that, with a set of images, any entity can determine the <, =, >

  12. Comparison on Computed Tomography using industrial items

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    2014-01-01

    In a comparison involving 27 laboratories from 8 countries, measurements on two common industrial items, a polymer part and a metal part, were carried out using X-ray Computed Tomography. All items were measured using coordinate measuring machines before and after circulation, with reference...

  13. Inter laboratory comparison on Industrial Computed Tomography

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; De Chiffre, Leonardo

    An interlaboratory comparison on industrial X-ray Computed Tomography (CT) was organized by the Centre for Geometrical Metrology (CGM), Department of Mechanical Engineering, Technical University of Denmark (DTU) and carried out within the project “Centre for Industrial Application of CT scanning...

  14. "Units of Comparison" across Languages, across Time

    Science.gov (United States)

    Thomas, Margaret

    2009-01-01

    Lardiere's keynote article adverts to a succession of "units of comparison" that have been employed in the study of cross-linguistic differences, including mid-twentieth-century structural patterns, generative grammar's parameters, and (within contemporary Minimalism) features. This commentary expands on the idea of units of cross-linguistic…

  15. Comparison of spent nuclear fuel management alternatives

    International Nuclear Information System (INIS)

    Beebe, C.L.; Caldwell, M.A.

    1996-01-01

    This paper reports the process an results of a trade study of spent nuclear fuel (SNF)management alternatives. The purpose of the trade study was to provide: (1) a summary of various SNF management alternatives, (2) an objective comparison of the various alternatives to facilitate the decision making process, and (3) documentation of trade study rational and the basis for decisions

  16. Comparison as a Universal Learning Action

    Science.gov (United States)

    Merkulova, T. V.

    2016-01-01

    This article explores "comparison" as a universal metasubject learning action, a key curricular element envisaged by the Russian Federal State Educational Standards. Representing the modern learner's fundamental pragmatic skill embedding such core capacities as information processing, critical thinking, robust decision-making, and…

  17. A Comparison of Software Schedule Estimators

    Science.gov (United States)

    1990-09-01

    SLIM ...................................... 33 SPQR /20 ................................... 35 System -4 .................................... 37 Previous...24 3. PRICE-S Outputs ..................................... 26 4. COCOMO Factors by Category ........................... 28 5. SPQR /20 Activities...actual schedules experienced on the projects. The models analyzed were REVIC, PRICE-S, System-4, SPQR /20, and SEER. ix A COMPARISON OF SOFTWARE

  18. Social Comparison of Pay and Inequity Theory.

    Science.gov (United States)

    Judd, Ben

    Inequity theory differs from social exchange theory in its analysis of a worker's reaction to pay by asserting that effects on work performance caused by high or low pay are due to social comparison of fairness rather than principles of direct exchange, such as reciprocity and power. The present experiment held piece-rate pay constant at two…

  19. Algorithmic parameterization of mixed treatment comparisons

    NARCIS (Netherlands)

    van Valkenhoef, Gert; Tervonen, Tommi; de Brock, Bert; Hillege, Hans

    Mixed Treatment Comparisons (MTCs) enable the simultaneous meta-analysis (data pooling) of networks of clinical trials comparing a parts per thousand yen2 alternative treatments. Inconsistency models are critical in MTC to assess the overall consistency between evidence sources. Only in the absence

  20. Algorithmic parameterization of mixed treatment comparisons

    NARCIS (Netherlands)

    G. van Valkenhoef (Gert); T. Tervonen (Tommi); B. de Brock (Bert)

    2012-01-01

    textabstractMixed Treatment Comparisons (MTCs) enable the simultaneous meta-analysis (data pooling) of networks of clinical trials comparing ≥2 alternative treatments. Inconsistency models are critical in MTC to assess the overall consistency between evidence sources. Only in the absence of

  1. Sequence Comparison: Close and Open problems

    NARCIS (Netherlands)

    Lenzini, Gabriele; Cerrai, P.; Freguglia, P.

    Comparing sequences is a very important activity both in computer science and in a many other areas as well. For example thank to text editors, everyone knows the particular instance of a sequence comparison problem knonw as ``string mathcing problem''. It consists in searching a given work

  2. 78 FR 38075 - International Labor Comparisons

    Science.gov (United States)

    2013-06-25

    ... concepts, definitions, and classifications to facilitate data comparisons between the United States and... referred to as sequestration) required by the Balanced Budget and Emergency Deficit Control Act, as amended..., Room 2120, 2 Massachusetts Avenue NE., Washington, DC 20212 or by email to: [email protected] . FOR...

  3. Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Oguzhan, A.; Kisacik, H.L.; Ozdemir, K.

    1997-01-01

    To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (ECG). Dobutamine echocardiography and exercise mibi-SPECT revealed a higher overall sensitivity than exercise testing (90 vs 57%, p 0.05; 90 and 62% p<0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, p<0.001; 89 vs 59%, p<0.001, respectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT. (author)

  4. Better than my loved ones: Social comparison tendencies among narcissists

    NARCIS (Netherlands)

    Krizan, Z.; Bushman, B.J.

    2011-01-01

    Narcissists pursue superiority and status at frequent costs to their relationships, and social comparisons seem central to these pursuits. Critically, these comparison tendencies should distinguish narcissism from healthy self-esteem. We tested this hypothesis in a study examining individual

  5. Atmospheric Correction Inter-comparison Exercise (ACIX)

    Science.gov (United States)

    Vermote, E.; Doxani, G.; Gascon, F.; Roger, J. C.; Skakun, S.

    2017-12-01

    The free and open data access policy to Landsat-8 (L-8) and Sentinel-2 (S-2) satellite imagery has encouraged the development of atmospheric correction (AC) approaches for generating Bottom-of-Atmosphere (BOA) products. Several entities have started to generate (or plan to generate in the short term) BOA reflectance products at global scale for L-8 and S-2 missions. To this end, the European Space Agency (ESA) and National Aeronautics and Space Administration (NASA) have initiated an exercise on the inter-comparison of the available AC processors. The results of the exercise are expected to point out the strengths and weaknesses, as well as communalities and discrepancies of various AC processors, in order to suggest and define ways for their further improvement. In particular, 11 atmospheric processors from five different countries participate in ACIX with the aim to inter-compare their performance when applied to L-8 and S-2 data. All the processors should be operational without requiring parametrization when applied on different areas. A protocol describing in details the inter-comparison metrics and the test dataset based on the AERONET sites has been agreed unanimously during the 1st ACIX workshop in June 2016. In particular, a basic and an advanced run of each of the processor were requested in the frame of ACIX, with the aim to draw robust and reliable conclusions on the processors' performance. The protocol also describes the comparison metrics of the aerosol optical thickness and water vapour products of the processors with the corresponding AERONET measurements. Moreover, concerning the surface reflectances, the inter-comparison among the processors is defined, as well as the comparison with the MODIS surface reflectance and with a reference surface reflectance product. Such a reference product will be obtained using the AERONET characterization of the aerosol (size distribution and refractive indices) and an accurate radiative transfer code. The inter-comparison

  6. Economic Comparison and Group Identity: Lessons from India

    OpenAIRE

    Xavier Fontaine; Katsunori Yamada

    2012-01-01

    The caste issue dominates a large part of India's social and political life. Caste shapes one's identity. Furthermore, strong tensions exist between castes. Using subjective well-being data, we assess the role economic comparisons play in this society. We focus on both within and between-castes comparisons. Within-caste comparisons appear to reduce well-being. Comparisons between rival castes are found to decrease well-being three times more. We link these results to two models in which econo...

  7. The relationship between social comparison processes and personality

    NARCIS (Netherlands)

    VanderZee, K; Buunk, B; Sanderman, R

    The relationship between social comparison processes and personality was examined in a sample of cancer patients (Study 1) and in a random population sample (Study 2). Previous studies showed that the need for comparison, its affective consequences and the tendency to make self-enhancing comparisons

  8. Quantum Private Comparison via Cavity QED

    International Nuclear Information System (INIS)

    Ye Tian-Yu

    2017-01-01

    The first quantum private comparison (QPC) protocol via cavity quantum electrodynamics (QED) is proposed in this paper by making full use of the evolution law of atom via cavity QED, where the third party (TP) is allowed to misbehave on his own but cannot conspire with either of the two users. The proposed protocol adopts two-atom product states rather than entangled states as the initial quantum resource, and only needs single-atom measurements for two users. Both the unitary operations and the quantum entanglement swapping operation are not necessary for the proposed protocol. The proposed protocol can compare the equality of one bit from each user in each round comparison with one two-atom product state. The proposed protocol can resist both the outside attack and the participant attack. Particularly, it can prevent TP from knowing two users’ secrets. Furthermore, the qubit efficiency of the proposed protocol is as high as 50%. (paper)

  9. Sorting processes with energy-constrained comparisons*

    Science.gov (United States)

    Geissmann, Barbara; Penna, Paolo

    2018-05-01

    We study very simple sorting algorithms based on a probabilistic comparator model. In this model, errors in comparing two elements are due to (1) the energy or effort put in the comparison and (2) the difference between the compared elements. Such algorithms repeatedly compare and swap pairs of randomly chosen elements, and they correspond to natural Markovian processes. The study of these Markov chains reveals an interesting phenomenon. Namely, in several cases, the algorithm that repeatedly compares only adjacent elements is better than the one making arbitrary comparisons: in the long-run, the former algorithm produces sequences that are "better sorted". The analysis of the underlying Markov chain poses interesting questions as the latter algorithm yields a nonreversible chain, and therefore its stationary distribution seems difficult to calculate explicitly. We nevertheless provide bounds on the stationary distributions and on the mixing time of these processes in several restrictions.

  10. Nonparametric predictive pairwise comparison with competing risks

    International Nuclear Information System (INIS)

    Coolen-Maturi, Tahani

    2014-01-01

    In reliability, failure data often correspond to competing risks, where several failure modes can cause a unit to fail. This paper presents nonparametric predictive inference (NPI) for pairwise comparison with competing risks data, assuming that the failure modes are independent. These failure modes could be the same or different among the two groups, and these can be both observed and unobserved failure modes. NPI is a statistical approach based on few assumptions, with inferences strongly based on data and with uncertainty quantified via lower and upper probabilities. The focus is on the lower and upper probabilities for the event that the lifetime of a future unit from one group, say Y, is greater than the lifetime of a future unit from the second group, say X. The paper also shows how the two groups can be compared based on particular failure mode(s), and the comparison of the two groups when some of the competing risks are combined is discussed

  11. Supplier Evaluation Process by Pairwise Comparisons

    Directory of Open Access Journals (Sweden)

    Arkadiusz Kawa

    2015-01-01

    Full Text Available We propose to assess suppliers by using consistency-driven pairwise comparisons for tangible and intangible criteria. The tangible criteria are simpler to compare (e.g., the price of a service is lower than that of another service with identical characteristics. Intangible criteria are more difficult to assess. The proposed model combines assessments of both types of criteria. The main contribution of this paper is the presentation of an extension framework for the selection of suppliers in a procurement process. The final weights are computed from relative pairwise comparisons. For the needs of the paper, surveys were conducted among Polish managers dealing with cooperation with suppliers in their enterprises. The Polish practice and restricted bidding are discussed, too.

  12. Comparison of energy performance requirements levels

    DEFF Research Database (Denmark)

    Spiekman, Marleen; Thomsen, Kirsten Engelund; Rose, Jørgen

    This summary report provides a synthesis of the work within the EU SAVE project ASIEPI on developing a method to compare the energy performance (EP) requirement levels among the countries of Europe. Comparing EP requirement levels constitutes a major challenge. From the comparison of for instance...... the present Dutch requirement level (EPC) of 0,8 with the present Flemish level of E80, it can easily be seen that direct comparison is not possible. The conclusions and recommendations of the study are presented in part A. These constitute the most important result of the project. Part B gives an overview...... of all other project material related to that topic, which allows to easily identify the most pertinent information. Part C lists the project partners and sponsors....

  13. Robot Trajectories Comparison: A Statistical Approach

    Directory of Open Access Journals (Sweden)

    A. Ansuategui

    2014-01-01

    Full Text Available The task of planning a collision-free trajectory from a start to a goal position is fundamental for an autonomous mobile robot. Although path planning has been extensively investigated since the beginning of robotics, there is no agreement on how to measure the performance of a motion algorithm. This paper presents a new approach to perform robot trajectories comparison that could be applied to any kind of trajectories and in both simulated and real environments. Given an initial set of features, it automatically selects the most significant ones and performs a statistical comparison using them. Additionally, a graphical data visualization named polygraph which helps to better understand the obtained results is provided. The proposed method has been applied, as an example, to compare two different motion planners, FM2 and WaveFront, using different environments, robots, and local planners.

  14. Robot Trajectories Comparison: A Statistical Approach

    Science.gov (United States)

    Ansuategui, A.; Arruti, A.; Susperregi, L.; Yurramendi, Y.; Jauregi, E.; Lazkano, E.; Sierra, B.

    2014-01-01

    The task of planning a collision-free trajectory from a start to a goal position is fundamental for an autonomous mobile robot. Although path planning has been extensively investigated since the beginning of robotics, there is no agreement on how to measure the performance of a motion algorithm. This paper presents a new approach to perform robot trajectories comparison that could be applied to any kind of trajectories and in both simulated and real environments. Given an initial set of features, it automatically selects the most significant ones and performs a statistical comparison using them. Additionally, a graphical data visualization named polygraph which helps to better understand the obtained results is provided. The proposed method has been applied, as an example, to compare two different motion planners, FM2 and WaveFront, using different environments, robots, and local planners. PMID:25525618

  15. Comparison exercise of probabilistic precursor analysis

    International Nuclear Information System (INIS)

    Fauchille, V.; Babst, S.

    2004-01-01

    From 2000 up to 2003, a comparison exercise concerning accident precursor programs was performed by IRSN, GRS, and NUPEC (Japan). The objective of this exercise was to compare the methodologies used to quantify conditional core damage probability related to incidents which can be considered as accident precursors. This exercise provided interesting results concerning the interpretation of such events. Generally, the participants identified similar scenarios of potential degradation. However, for several dominant sequences, differences in the results were noticed. The differences can be attributed to variations in the plant design, the strategy of management and in the methodological approach. For many reasons, comparison of human reliability analysis was difficult and perhaps another exercise in the future could provide more information about this subject. On the other hand, interesting outcomes have been obtained from the quantification of both common cause failures and potential common cause failures. (orig.)

  16. Patent documentation - comparison of two MT strategies

    DEFF Research Database (Denmark)

    Offersgaard, Lene; Povlsen, Claus

    2007-01-01

    This paper focuses on two matters: A comparison of how two different MT strategies manage translating the text type of patent documentation and a survey of what is needed to transform a MT research prototype system to a translation application for patent texts. The two MT strategies is represented....... The distinctive text type of patents pose special demands for machine translation and these aspects are discussed based on linguistic observations with focus on the users point of view. Two main demands are automatic pre processing of the documents and implementation of a module which in a flexible and user......-friendly manner offers the opportunity to extend the lexical coverage of the system. These demands and the comparison of the two MT strategies are discussed on the basis of proofread patents....

  17. Fatigue and rupture codified rules comparison

    International Nuclear Information System (INIS)

    Faidy, C.

    2004-01-01

    The European Directive on Pressure Equipment requests risk studies and in particular to assure no risk of fatigue and rupture in operation. The answers to these questions are different in the different existing design codes (EN Standards, ASME III and VIII or RCC-M or CODAP-CODETI codes) and corresponding in operation codes (ASME or RSE-M). Design safety factors, material properties, fabrication, refinement in the analysis methods, monitoring in operation, hydro-proof test level... Around these Codes, different rules are under development. A16 in France, R6 in UK or FITNET at the EC level. This paper is concerned by a comparison between 2 different Codes to analyze the risk of fatigue or rupture of pressure equipments and mainly a comparison between RCC-M Code and EN 13445 standard for pressure vessel. Recommendations for future work will be proposed. (authors)

  18. Kruskal-Wallis Test in Multiple Comparisons

    OpenAIRE

    Parys, Dariusz

    2009-01-01

    In this paper we show that the Kruskal-Wallis test can be transform to quadratic form among the Mann-Whitney or Kendal τ au concordance measures between pairs of treatments. A multiple comparisons procedure based on patterns of transitive ordering among treatments is implement. We also consider the circularity and non-transitive effects. Statystyka testu Kruskala-Wallisa przedstawiona jest w postaci formy kwadratowej z użyciem statystyki Manna-Whitneya lub miar konkordacji τ au Kendalla. N...

  19. Costs comparison of electric energy in Brazil

    International Nuclear Information System (INIS)

    Goncalves, D.; Menegassi, J.

    1981-01-01

    A cost comparison study of various sources of electric energy generation was performed using uniform analysis criteria. The results indicate higher costs for coal, followed by nuclear and hidro. It was verified that presently, large hidro-power plants can only be located far from the load centers, with increasing costs of hidro-power energy in Brazil. These costs become higher than the nuclear plant if the hidro plant is located at distances exceeding 1000 Km. (Author) [pt

  20. Energy security externalities and fuel cycle comparisons

    International Nuclear Information System (INIS)

    Bohi, D.; Toman, M.

    1994-01-01

    Externalities related to 'energy security' may be one way in which the full social costs of energy use diverge from the market prices of energy commodities. Such divergences need to be included in reckoning the full costs of different fuel cycles. In this paper we critically examine potential externalities related to energy security and issues related to the measurement of 2 these externalities, in the context of fuel cycle comparisons

  1. Traditional marketing vs. Internet marketing. A comparison

    OpenAIRE

    Varfan, Mona; Shima, Alfa

    2008-01-01

    Title: Traditional marketing vs. Internet marketing: A comparison Problem: Marketing is an important strategy for businesses and it contains numerous effective tools. Traditional marketing has been in use for many years and nowadays Internet has brought new ways of doing business for companies and that has affected marketing. What are the main differences between Internet marketing and traditional marketing? Which one of the two approaches contains the most used and effective marketing tools ...

  2. Comparison of Remote Labs in Different Technologies

    OpenAIRE

    Christian Mergl

    2006-01-01

    Recently several possibilities arose to conduct electronic measurement experiments via remote control. Now a comparison of the latest different technologies should bring some answers to interested people, so that they can choose the best technology for them under their criteria. Criteria in this case are, the up-to-dateness of the technology, the development-time, the system-independency of the client in terms of the operating system and internet browser as well as other necessary installatio...

  3. Comparison of investment opportunities in mutual funds

    OpenAIRE

    NOVÁKOVÁ, Petra

    2012-01-01

    This thesis deals with the comparison of selected mutual funds in the Czech Republic. The main aim of this thesis is to evaluate the situation on the securities market of mutual funds and help to the investor with right choice of mutual fund. Work is initially devoted to the characteristics and history of collective investment. The following section describes mutual funds their characteristics, classification, creation and termination. Conclusion of the theoretical part is devoted to investme...

  4. Level comparison theorems and supersymmetric quantum mechanics

    International Nuclear Information System (INIS)

    Baumgartner, B.; Grosse, H.

    1986-01-01

    The sign of the Laplacian of the spherical symmetric potential determines the order of energy levels with the same principal Coulomb quantum number. This recently derived theorem has been generalized, extended and applied to various situations in particle, nuclear and atomic physics. Besides a comparison theorem the essential step was the use of supersymmetric quantum mechanics. Recently worked out applications of supersymmetric quantum mechanics to index problems of Dirac operators are mentioned. (Author)

  5. Energy security externalities and fuel cycle comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Bohi, D; Toman, M

    1994-07-01

    Externalities related to 'energy security' may be one way in which the full social costs of energy use diverge from the market prices of energy commodities. Such divergences need to be included in reckoning the full costs of different fuel cycles. In this paper we critically examine potential externalities related to energy security and issues related to the measurement of 2 these externalities, in the context of fuel cycle comparisons.

  6. comparison of english and chinese advertisement slogan

    Institute of Scientific and Technical Information of China (English)

    张悦

    2011-01-01

    advertisements in cross-culture communication come from different cultural background.the english and chinese advertisement slogan is a lively and distinctive field.differences of advertising slogan are becoming more important in the context of economic globalization.this paper,from the comparison of chinese and english advertisement slogan,language used in slogans,translation of slogan,mainly from the points of view of cross-culture to analysis the differences of tow language ads slogan.

  7. Olympic games in Sochi, comparison and forecast

    OpenAIRE

    Kudrina, Anastasia

    2015-01-01

    Title: Olympic Games in Sochi, comparison and prediction Goals: Based on a research of the Olympic Games in Sochi to create a forecast of future economic effects on the territorium Method: The prediction is based on the analogic situation in other countries that held the Olympic Games in the past. Induction method of representing the thought process, during which the individual facts formulate more general assertions and theories; deduction method, which are derived from the general conclusio...

  8. Explosive Infrasonic Events: Sensor Comparison Experiment (SCE)

    Energy Technology Data Exchange (ETDEWEB)

    Schnurr, J. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Garces, M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rodgers, A. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-06

    SCE (sensor comparison experiment) 1 through 4 consists of a series of four controlled above-ground explosions designed to provide new data for overpressure propagation. Infrasound data were collected by LLNL iPhones and other sensors. Origin times, locations HOB, and yields are not being released at this time and are therefore not included in this report. This preliminary report will be updated as access to additional data changes, or instrument responses are determined.

  9. COBRA-IV wire wrap data comparisons

    International Nuclear Information System (INIS)

    Donovan, T.E.; George, T.L.; Wheeler, C.L.

    1979-02-01

    Thermal hydraulic analyses of hexagonally packed wire-wrapped fuel assemblies are complicated by the induced crossflow between adjacent subchannels. The COBRA-IV computer code simultaneously solves the hydrodynamics and thermodynamics of fuel assemblies. The modifications and the results are presented which are predicted by the COBRA-IV calculation. Comparisons are made with data measured in five experimental models of a wire-wrapped fuel assembly

  10. Strain comparisons in aquaculture species: a manual

    OpenAIRE

    Ponzoni, R.W.; James, J.W.; Nguyen, N.H.; Mekkawy, W.; Khaw, H.L.

    2013-01-01

    When different strains or breeds of a particular species are available, the best choice is seldom immediately obvious for producers. Scientists are also interested in the relative performance of different strains because it provides a basis for recommendations to producers and it often stimulates the conduct of work aimed at unraveling the underlying biological mechanisms involved in the expression of such differences. Hence, strain or breed comparisons of some sort are frequently conducted. ...

  11. Atmospheric Correction Inter-Comparison Exercise

    Directory of Open Access Journals (Sweden)

    Georgia Doxani

    2018-02-01

    Full Text Available The Atmospheric Correction Inter-comparison eXercise (ACIX is an international initiative with the aim to analyse the Surface Reflectance (SR products of various state-of-the-art atmospheric correction (AC processors. The Aerosol Optical Thickness (AOT and Water Vapour (WV are also examined in ACIX as additional outputs of AC processing. In this paper, the general ACIX framework is discussed; special mention is made of the motivation to initiate the experiment, the inter-comparison protocol, and the principal results. ACIX is free and open and every developer was welcome to participate. Eventually, 12 participants applied their approaches to various Landsat-8 and Sentinel-2 image datasets acquired over sites around the world. The current results diverge depending on the sensors, products, and sites, indicating their strengths and weaknesses. Indeed, this first implementation of processor inter-comparison was proven to be a good lesson for the developers to learn the advantages and limitations of their approaches. Various algorithm improvements are expected, if not already implemented, and the enhanced performances are yet to be assessed in future ACIX experiments.

  12. Misleading Comparisons between Chernobyl and Fukushima

    International Nuclear Information System (INIS)

    Hiranuma, Yuri

    2016-01-01

    This paper critically analyzes illogical and often misleading comparisons between Fukushima and Chernobyl where the nuclear accidents have occurred. A letter by Takamura et al. published in The Lancet Diabetes and Endocrinology makes comparisons between the exposure doses and the age distributions of childhood thyroid cancer cases in Belarus and Fukushima. Estimated exposure doses in highly contaminated areas in Belarus were compared with potentially underestimated Fukushima doses. Age distributions of thyroid cancer cases are compared at different times after the accidents: after 4-5 years in Belarus vs. first 4 years in Fukushima. The absence of cancer cases in ages 0-5 at exposure in Fukushima in the first 4 years after the accident is not surprising because the supposed latency of childhood thyroid cancer is considered 4-5 years based on the Chernobyl experience. Yet this absence is claimed as a basis leading to a premature conclusion to dismiss radiation effects on thyroid cancer cases in Fukushima. Similar illogical comparisons made in Japan and overseas are discussed. A possibility of a shorter latency period is entertained based on a carcinogenic potential of ionizing radiation as initiator as well as promoter. Lastly, a pooled analysis of 12 studies on thyroid cancer after childhood external exposure (2016) is introduced as an evidence that exposure doses below 100 mGy lead to an increase in relative risk of thyroid cancer with a linear dose-response. (author)

  13. Selecting numerical scales for pairwise comparisons

    International Nuclear Information System (INIS)

    Elliott, Michael A.

    2010-01-01

    It is often desirable in decision analysis problems to elicit from an individual the rankings of a population of attributes according to the individual's preference and to understand the degree to which each attribute is preferred to the others. A common method for obtaining this information involves the use of pairwise comparisons, which allows an analyst to convert subjective expressions of preference between two attributes into numerical values indicating preferences across the entire population of attributes. Key to the use of pairwise comparisons is the underlying numerical scale that is used to convert subjective linguistic expressions of preference into numerical values. This scale represents the psychological manner in which individuals perceive increments of preference among abstract attributes and it has important implications about the distribution and consistency of an individual's preferences. Three popular scale types, the traditional integer scales, balanced scales and power scales are examined. Results of a study of 64 individuals responding to a hypothetical decision problem show that none of these scales can accurately capture the preferences of all individuals. A study of three individuals working on an actual engineering decision problem involving the design of a decay heat removal system for a nuclear fission reactor show that the choice of scale can affect the preferred decision. It is concluded that applications of pairwise comparisons would benefit from permitting participants to choose the scale that best models their own particular way of thinking about the relative preference of attributes.

  14. International Comparisons: Issues of Methodology and Practice

    Directory of Open Access Journals (Sweden)

    Serova Irina A.

    2017-12-01

    Full Text Available The article discusses the methodology and organization of statistical observation of the level of countries’ economic development. The theoretical basis of international comparisons is singled out and on its basis the comparative evaluation of inconsistency of theoretical positions and the reasons of differences of GDP growth is carried out. Based on the complexity of the formation of homogeneous data sets in order to obtain correct comparison results, a general scheme for the relationship between the theoretical base of international comparisons and PPP constraints is defined. The possibility of obtaining a single measurement of the indicators of national economies based on the existing sampling errors, measurement uncertainties and classification errors is considered. The emphasis is placed on combining the work using the ICP and CPI with the aim of achieving comparability of data in the territorial and temporal cross-section. Using the basic characteristics of sustainable economic growth, long-term prospects for changing the ranking positions of countries with different levels of income are determined. It is shown that the clarity and unambiguity of the theoretical provisions is the defining condition for the further process of data collection and formation of correct analytical conclusions.

  15. Task-Driven Comparison of Topic Models.

    Science.gov (United States)

    Alexander, Eric; Gleicher, Michael

    2016-01-01

    Topic modeling, a method of statistically extracting thematic content from a large collection of texts, is used for a wide variety of tasks within text analysis. Though there are a growing number of tools and techniques for exploring single models, comparisons between models are generally reduced to a small set of numerical metrics. These metrics may or may not reflect a model's performance on the analyst's intended task, and can therefore be insufficient to diagnose what causes differences between models. In this paper, we explore task-centric topic model comparison, considering how we can both provide detail for a more nuanced understanding of differences and address the wealth of tasks for which topic models are used. We derive comparison tasks from single-model uses of topic models, which predominantly fall into the categories of understanding topics, understanding similarity, and understanding change. Finally, we provide several visualization techniques that facilitate these tasks, including buddy plots, which combine color and position encodings to allow analysts to readily view changes in document similarity.

  16. Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the same radiation dose: Comparison of motion artifacts, diagnostic confidence and signal-to-noise-ratios

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger E.; Stadler, Alfred; Beitzke, Dietrich; Homolka, Peter; Weber, Michael; Lammer, Johannes; Czerny, Martin; Loewe, Christian

    2012-01-01

    Purpose: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). Materials and methods: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. Results: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p < 0.001) and DC (p < 0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p < 0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p < 0.001), but not a statistically significant higher DC (p = 0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p = 0.861 and 0.526, respectively) and DC (p = 1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24 mSv; range, 18.43–25.94 mSv) did not differ significantly (p = 0.051) from that of non-gated CT angiography (24.28 mSv; range, 19.37–29.27 mSv). Conclusion: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.

  17. Comparison of real development levels of countries: Genesis and perspectives

    Directory of Open Access Journals (Sweden)

    Prekajac Zora

    2007-01-01

    Full Text Available Comparison of levels of development among countries is usually done by reducing values in national currencies with a common denominator, using the official exchange rate. Because of its unreality, the values calculated in this way do not illustrate real relations between compared countries. That brings about the launching of the UN International Comparison Project (latter Programme with two fold aims: developing a method for international comparison of real domestic product which could be applied to a number of very heterogeneous countries, and the comparison of growing number of very different countries. Until now six phases of comparisons are finished. Taking into consideration problems that appeared in the realization of the VI ICP phase as well as quality improvement proposals, a decision has been made to launch a new, global round for 2003-2006. Comparison will cover 150 countries (the widest coverage ever. This will give global character to the comparison, which was the end cause of the ICP.

  18. A Comparison of Physiological Signal Analysis Techniques and Classifiers for Automatic Emotional Evaluation of Audiovisual Contents.

    Science.gov (United States)

    Colomer Granero, Adrián; Fuentes-Hurtado, Félix; Naranjo Ornedo, Valery; Guixeres Provinciale, Jaime; Ausín, Jose M; Alcañiz Raya, Mariano

    2016-01-01

    This work focuses on finding the most discriminatory or representative features that allow to classify commercials according to negative, neutral and positive effectiveness based on the Ace Score index. For this purpose, an experiment involving forty-seven participants was carried out. In this experiment electroencephalography (EEG), electrocardiography (ECG), Galvanic Skin Response (GSR) and respiration data were acquired while subjects were watching a 30-min audiovisual content. This content was composed by a submarine documentary and nine commercials (one of them the ad under evaluation). After the signal pre-processing, four sets of features were extracted from the physiological signals using different state-of-the-art metrics. These features computed in time and frequency domains are the inputs to several basic and advanced classifiers. An average of 89.76% of the instances was correctly classified according to the Ace Score index. The best results were obtained by a classifier consisting of a combination between AdaBoost and Random Forest with automatic selection of features. The selected features were those extracted from GSR and HRV signals. These results are promising in the audiovisual content evaluation field by means of physiological signal processing.

  19. Comparison of patients with and without intellectual disability under general anesthesia: A retrospective study.

    Science.gov (United States)

    Sitilci, T; Demirgan, S; Akcay, C; Kahraman, N; Koseoglu, B G; Erdem, M A; Cankaya, A B

    2017-04-01

    We analyzed and retrospectively compared patients with and without intellectual disability (ID) who underwent oral surgery under general anesthesia at Istanbul University, Faculty of Dentistry, Department of General Anesthesia, between October 2012 and June 2013 with regard to the following categories: Demographic features, American Society of Anesthesiologists (ASA) classification, Mallampati score, type of anesthetic drug used during the operation, type of intubation used, any difficulties with tracheal intubation, presence of systemic diseases, and recovery times after ending general anesthesia. A total of 348 patients were selected from the Department of Maxillofacial Surgery and the Department of Pedodontics who underwent surgery with general anesthesia. Medical histories of all patients were taken, and their electrocardiography, chest X-rays, complete blood count, and blood clotting tests were checked during a preoperative assessment. Mallampati evaluations were also performed. Patients were grouped into ASA I, II, or III according to the ASA classification and were treated under general anesthesia. There was no significant difference between normal and intellectually disabled patients in terms of gender, Mallampati scores, intubation difficulties, mean anesthetic period, time to discharge, or postoperative nausea and vomiting. Epilepsy and genetic diseases in intellectually disabled patients were significantly more common than in non-ID (NID) patients. However, the frequency of diabetes and chronic obstructive pulmonary disease in NID patients was significantly higher than in the intellectually disabled patients. Dental treatment of intellectually disabled patients under general anesthesia can be performed just as safely as that with NID patients.

  20. ACCELERATION RENDERING METHOD ON RAY TRACING WITH ANGLE COMPARISON AND DISTANCE COMPARISON

    Directory of Open Access Journals (Sweden)

    Liliana liliana

    2007-01-01

    Full Text Available In computer graphics applications, to produce realistic images, a method that is often used is ray tracing. Ray tracing does not only model local illumination but also global illumination. Local illumination count ambient, diffuse and specular effects only, but global illumination also count mirroring and transparency. Local illumination count effects from the lamp(s but global illumination count effects from other object(s too. Objects that are usually modeled are primitive objects and mesh objects. The advantage of mesh modeling is various, interesting and real-like shape. Mesh contains many primitive objects like triangle or square (rare. A problem in mesh object modeling is long rendering time. It is because every ray must be checked with a lot of triangle of the mesh. Added by ray from other objects checking, the number of ray that traced will increase. It causes the increasing of rendering time. To solve this problem, in this research, new methods are developed to make the rendering process of mesh object faster. The new methods are angle comparison and distance comparison. These methods are used to reduce the number of ray checking. The rays predicted will not intersect with the mesh, are not checked weather the ray intersects the mesh. With angle comparison, if using small angle to compare, the rendering process will be fast. This method has disadvantage, if the shape of each triangle is big, some triangles will be corrupted. If the angle to compare is bigger, mesh corruption can be avoided but the rendering time will be longer than without comparison. With distance comparison, the rendering time is less than without comparison, and no triangle will be corrupted.

  1. SUPPLEMENTARY COMPARISON: Final report on APMP.PR-S1.1: Bilateral comparison of irradiance responsivity of UVA detectors

    Science.gov (United States)

    Huang, Xuebo

    2009-01-01

    In order to assess the performance of the standards and techniques used for calibration and measurement of UVA irradiance responsivity of photodetectors in NMISA, South Africa, a new comparison was decided as a follow-up to comparison APMP.PR-S1. It is registered in the Key Comparison Data Base (KCDB) of BIPM as a bilateral supplementary comparison, with the identifier APMP.PR-S1.1. The comparison was carried out following the same technical protocol as that of supplementary comparison APMP PR-S1. The principle, organization and method of the comparison, as well as the preliminary measurements at the pilot laboratory NMC-A*STAR Singapore, were described in the Final Report of the APMP.PR-S1 comparison. The results of this bilateral comparison show that the NMISA's results lie within ±2% against the comparison reference values of APMP.PR-S1, which is a great improvement. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the APMP, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Comparison between radioisotopic ventriculography in balance with Tc99-albumine-DTPA and quantitative gated SPECT with Tc-99m-MIBI for determining the eject fraction of left ventricle

    International Nuclear Information System (INIS)

    Noguera, E. C; Jaime, Adelina; Pamellin, Miriam; Veliz, J

    2002-01-01

    Radionuclide ventriculography (RNV) and electrocardiography gated myocardial perfusion single photon emission computed tomography (GSPECT), can be used to assess the ventricular function.The purpose of this study was:1) to compare left ventricular ejection fraction (LVEF(%) using post-stress or rest gated GSPECT with LVEF by resting RNV and 2) to evaluate the 99m-Tc99m human serum albumin (HAS) with diethylenetriaminepenta-acetic acid (DTPA) (99m-TcHSA-DTPA) as a potential use a as blood pool imaging agent (Au)

  3. Results from the FIN-2 formal comparison

    Science.gov (United States)

    Connolly, Paul; Hoose, Corinna; Liu, Xiaohong; Moehler, Ottmar; Cziczo, Daniel; DeMott, Paul

    2017-04-01

    During the Fifth International Ice Nucleation Workshop (FIN-2) at the AIDA Ice Nucleation facility in Karlsruhe, Germany in March 2015, a formal comparison of ice nucleation measurement methods was conducted. During the experiments the samples of ice nucleating particles were not revealed to the instrument scientists, hence this was referred to as a "blind comparison". The two samples used were later revealed to be Arizona Test Dust and an Argentina soil sample. For these two samples seven mobile ice nucleating particle counters sampled directly from the AIDA chamber or from the aerosol preparation chamber at specified temperatures, whereas filter samples were taken for two offline deposition nucleation instruments. Wet suspension methods for determining IN concentrations were also used with 10 different methods employed. For the wet suspension methods experiments were conducted using INPs collected from the air inside the chambers (impinger sampling) and INPs taken from the bulk samples (vial sampling). Direct comparisons of the ice nucleating particle concentrations are reported as well as derived ice nucleation active site densities. The study highlights the difficulties in performing such analyses, but generally indicates that there is reasonable agreement between the wet suspension techniques. It is noted that ice nucleation efficiency derived from the AIDA chamber (quantified using the ice active surface site density approach) is higher than that for the cold stage techniques. This is both true for the Argentina soil sample and, to a lesser extent, for the Arizona Test Dust sample too. Other interesting effects were noted: for the ATD the impinger sampling demonstrated higher INP efficiency at higher temperatures (>255 K) than the vial sampling, but agreed at the lower temperatures (<255K), whereas the opposite was true for the Argentina soil sample. The results are analysed to better understand the performance of the various techniques and to address any

  4. Comparison of RESRAD with hand calculations

    International Nuclear Information System (INIS)

    Rittmann, P.D.

    1995-09-01

    This report is a continuation of an earlier comparison done with two other computer programs, GENII and PATHRAE. The dose calculations by the two programs were compared with each other and with hand calculations. These band calculations have now been compared with RESRAD Version 5.41 to examine the use of standard models and parameters in this computer program. The hand calculations disclosed a significant computational error in RESRAD. The Pu-241 ingestion doses are five orders of magnitude too small. In addition, the external doses from some nuclides differ greatly from expected values. Both of these deficiencies have been corrected in later versions of RESRAD

  5. Comparison between Dutch and German buildings

    Energy Technology Data Exchange (ETDEWEB)

    Lony, R.J.M.; Molenaar, D.J.; Rietkerk, J.; Schuiling, D.J.B.W.; Zeiler, W. [TU/e, Univ. of Technology Eindhoven (Netherlands); Brunk, M. [RWTH Aachen (Germany)

    2006-07-01

    German buildings are often seen as an example to Dutch architects and Dutch building services consultants. Goal of this article is to examine and to understand differences between the Dutch and German top office buildings. Objective is to examine to which extent these buildings were designed intelligently. An Intelligent Building is one that provides a productive cost effective environment through the optimisation of six basic elements; site, skin, systems, structures, services, space plan and staff and the interrelationship between them. Based on these six aspects the comparison is made between Dutch and German buildings. (orig.)

  6. Comparison of future energy scenarios for Denmark

    DEFF Research Database (Denmark)

    Kwon, Pil Seok; Østergaard, Poul Alberg

    2012-01-01

    Scenario-making is becoming an important tool in energy policy making and energy systems analyses. This article probes into the making of scenarios for Denmark by presenting a comparison of three future scenarios which narrate 100% renewable energy system for Denmark in 2050; IDA 2050, Climate...... Commission 2050, and CEESA (Coherent Energy and Environmental System Analysis). Generally, although with minor differences, the scenarios suggest the same technological solutions for the future such as expansion of biomass usage and wind power capacity, integration of transport sector into the other energy...

  7. Comparison of alternate fuels for aircraft

    Science.gov (United States)

    Witcofski, R. D.

    1979-01-01

    A comparison of candidate alternate fuels for aircraft is presented. The fuels discussed include liquid hydrogen, liquid methane, and synthetic aviation kerosene. Each fuel is evaluated from the standpoint of production, transmission, airport storage and distribution facilities, and use in aircraft. Technology deficient areas for cryogenic fuels, which should be advanced prior to the introduction of the fuels into the aviation industry, are identified, as are the cost and energy penalties associated with not achieving those advances. Environmental emissions and safety aspects of fuel selection are discussed. A detailed description of the various fuel production and liquefaction processes and their efficiencies and economics is given.

  8. Comparison of Remote Labs in Different Technologies

    Directory of Open Access Journals (Sweden)

    Christian Mergl

    2006-11-01

    Full Text Available Recently several possibilities arose to conduct electronic measurement experiments via remote control. Now a comparison of the latest different technologies should bring some answers to interested people, so that they can choose the best technology for them under their criteria. Criteria in this case are, the up-to-dateness of the technology, the development-time, the system-independency of the client in terms of the operating system and internet browser as well as other necessary installations on the client.

  9. Comparison between Microfabrication Technologies for Metal Tooling

    DEFF Research Database (Denmark)

    Tang, Peter Torben

    2005-01-01

    of metal. The following technologies have been analysed: micromilling, microEDM (microelectro discharge machining, including wire-EDM, sinking-EDM and EDM-milling), laser micromachining, electroforming and ECF (an innovative process proposed by HSG-IMAT). Considered materials are nickel for electroforming......, stainless steel for ECF, and tool steel (AISI H13) for the other processes. Typical features (ribs, channels, pins and holes) required by microoptics, microfluidics and sensors and actuators applications have been selected to carry out this analysis The task results provide a global comparison between...

  10. Preference Learning and Ranking by Pairwise Comparison

    Science.gov (United States)

    Fürnkranz, Johannes; Hüllermeier, Eyke

    This chapter provides an overview of recent work on preference learning and ranking via pairwise classification. The learning by pairwise comparison (LPC) paradigm is the natural machine learning counterpart to the relational approach to preference modeling and decision making. From a machine learning point of view, LPC is especially appealing as it decomposes a possibly complex prediction problem into a certain number of learning problems of the simplest type, namely binary classification. We explain how to approach different preference learning problems, such as label and instance ranking, within the framework of LPC. We primarily focus on methodological aspects, but also address theoretical questions as well as algorithmic and complexity issues.

  11. Comparison of Shallow Survey 2012 Multibeam Datasets

    Science.gov (United States)

    Ramirez, T. M.

    2012-12-01

    The purpose of the Shallow Survey common dataset is a comparison of the different technologies utilized for data acquisition in the shallow survey marine environment. The common dataset consists of a series of surveys conducted over a common area of seabed using a variety of systems. It provides equipment manufacturers the opportunity to showcase their latest systems while giving hydrographic researchers and scientists a chance to test their latest algorithms on the dataset so that rigorous comparisons can be made. Five companies collected data for the Common Dataset in the Wellington Harbor area in New Zealand between May 2010 and May 2011; including Kongsberg, Reson, R2Sonic, GeoAcoustics, and Applied Acoustics. The Wellington harbor and surrounding coastal area was selected since it has a number of well-defined features, including the HMNZS South Seas and HMNZS Wellington wrecks, an armored seawall constructed of Tetrapods and Akmons, aquifers, wharves and marinas. The seabed inside the harbor basin is largely fine-grained sediment, with gravel and reefs around the coast. The area outside the harbor on the southern coast is an active environment, with moving sand and exposed reefs. A marine reserve is also in this area. For consistency between datasets, the coastal research vessel R/V Ikatere and crew were used for all surveys conducted for the common dataset. Using Triton's Perspective processing software multibeam datasets collected for the Shallow Survey were processed for detail analysis. Datasets from each sonar manufacturer were processed using the CUBE algorithm developed by the Center for Coastal and Ocean Mapping/Joint Hydrographic Center (CCOM/JHC). Each dataset was gridded at 0.5 and 1.0 meter resolutions for cross comparison and compliance with International Hydrographic Organization (IHO) requirements. Detailed comparisons were made of equipment specifications (transmit frequency, number of beams, beam width), data density, total uncertainty, and

  12. The Comparison Study of Six University Archives

    Directory of Open Access Journals (Sweden)

    Chun-Fen Liu

    2004-03-01

    Full Text Available The university archives is not only the extension of a building, but also includes the archival records, archivists and equipments. The university archives is the historical memory of a university, which could let people to predict the future by reviewing the past. The university archives has abundant collections, both teachers and students can review history of this university. This paper mainly compares six university archives of Taiwan, and the interviewing method is used in this research. After comparison of the six university archives, we have found the six university archives have different organizational structures, budgets, and functions. Finally the authors propose some suggestions.[Article content in Chinese

  13. Comparison between calorimeter and HLNC errors

    International Nuclear Information System (INIS)

    Goldman, A.S.; De Ridder, P.; Laszlo, G.

    1991-01-01

    This paper summarizes an error analysis that compares systematic and random errors of total plutonium mass estimated for high-level neutron coincidence counter (HLNC) and calorimeter measurements. This task was part of an International Atomic Energy Agency (IAEA) study on the comparison of the two instruments to determine if HLNC measurement errors met IAEA standards and if the calorimeter gave ''significantly'' better precision. Our analysis was based on propagation of error models that contained all known sources of errors including uncertainties associated with plutonium isotopic measurements. 5 refs., 2 tabs

  14. Rooftop Unit Comparison Calculator User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Miller, James D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-04-30

    This document serves as a user manual for the Packaged rooftop air conditioners and heat pump units comparison calculator (RTUCC) and is an aggregation of the calculator’s website documentation. Content ranges from new-user guide material like the “Quick Start” to the more technical/algorithmic descriptions of the “Methods Pages.” There is also a section listing all the context-help topics that support the features on the “Controls” page. The appendix has a discussion of the EnergyPlus runs that supported the development of the building-response models.

  15. The politics of comparison in mediated publics

    DEFF Research Database (Denmark)

    Birkbak, Andreas

    News media and social media are often compared in a way that focuses on their contrasts, e.g. as between objective news and passionate opinions – or between a clear-cut public and multiple issue-oriented quasi-publics. If we do not assume such divisions to be pre-given, it becomes possible to study...... of mediated publics. Here, the researcher can begin to think with and not just about contemporary media practices when trying to rethink comparison and its politics....

  16. Benefit/risk comparisons in diagnostic radiology

    International Nuclear Information System (INIS)

    Oosterkamp, W.J.

    1976-01-01

    Benefit and risks in radiodiagnostic examination, either with X-rays or with radioactive isotopes, can be expressed in restored health and health impaired by radiation or: lives saved and estimated lives lost as a result of genetic or somatic radiation damage. Published data on benefit-risk comparisons for mass stomach and chest surveys show a considerable benefit surplus. It is demonstrated that this is also true in the case of clinical examinations of the sick. Efforts should be concentrated on better ways and means to reduce the number of diagnostic errors. Risk estimates should be made as realistic as possible

  17. Individual differences on social comparison : properties of the orientation Spanish scale towards social comparison

    NARCIS (Netherlands)

    Buunk, AP; Belmonte, J; Peiro, JM; Zurriaga, R; Gibbons, FX

    2005-01-01

    This paper describes the development and the properties of the INCOM-E, the Spanish language version of the INCOM, a measure to assess individual differences in social comparison orientation that was originally developed simultaneously in English and in Dutch. In both Study 1 (including 212

  18. Smart Grid communication middleware comparison distributed control comparison for the internet of things

    DEFF Research Database (Denmark)

    Petersen, Bo Søborg; Bindner, Henrik W.; Poulsen, Bjarne

    2017-01-01

    are possible by their performance, which is limited by the middleware characteristics, primarily interchangeable serialization and the Publish-Subscribe messaging pattern. The earlier paper "Smart Grid Serialization Comparison" (Petersen et al. 2017) AIDS in the choice of serialization, which has a big impact...

  19. Is nuclear economical in comparison to renewables?

    International Nuclear Information System (INIS)

    Suna, Demet; Resch, Gustav

    2016-01-01

    The European Union is divided on the issue of electricity production. While there is consensus that generation technologies need to be low on greenhouse gas emissions, the question of whether to use renewables or nuclear to meet this power demand is highly controversial. Both options still require financial support and this is not going to change in the near future. This raises the question of where public money should be invested in order to achieve greater economic efficiency: into support for renewable energies (RE) or support for nuclear power plants? This paper sets out to answer this question. The detailed model-based prospective scenario assessment performed in this study provides the basis for estimating future cost developments. After discussing the existing support schemes for renewables, the paper compares these with a nuclear model. The comparison is conducted exemplarily for the United Kingdom (UK) at a country level and for the EU 28 overall. The recent state aid case for the construction of the Hinkley Point nuclear power plant (NPP) in the UK serves as the model for the nuclear option. - Highlights: • State aids for new nuclear power is compared with incentives for renewables. • Hinkley Point C in the UK is considered as example for new nuclear power. • Comparison is conducted for the UK at a country level and for the EU 28 overall. • Analysis shows that renewable energies are more economical than nuclear power.

  20. Thermal sensation models: a systematic comparison.

    Science.gov (United States)

    Koelblen, B; Psikuta, A; Bogdan, A; Annaheim, S; Rossi, R M

    2017-05-01

    Thermal sensation models, capable of predicting human's perception of thermal surroundings, are commonly used to assess given indoor conditions. These models differ in many aspects, such as the number and type of input conditions, the range of conditions in which the models can be applied, and the complexity of equations. Moreover, the models are associated with various thermal sensation scales. In this study, a systematic comparison of seven existing thermal sensation models has been performed with regard to exposures including various air temperatures, clothing thermal insulation, and metabolic rate values after a careful investigation of the models' range of applicability. Thermo-physiological data needed as input for some of the models were obtained from a mathematical model for human physiological responses. The comparison showed differences between models' predictions for the analyzed conditions, mostly higher than typical intersubject differences in votes. Therefore, it can be concluded that the choice of model strongly influences the assessment of indoor spaces. The issue of comparing different thermal sensation scales has also been discussed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Comparison of several potential myocardial imaging agents

    International Nuclear Information System (INIS)

    Watson, E.E.; Stabin, M.G.; Goodman, M.M.; Knapp, F.F. Jr.; Srivastava, P.C.

    1985-01-01

    Although myocardial imaging is currently dominated by Tl-201, several alternative agents with improved physiologic or radionuclidic properties have been proposed. Based on human and animal studies in the literature, the metabolism of several of these compounds was studied for the purpose of generating radiation dose estimates. Dose estimates are listed for several I-123 labeled free fatty acids, an I-123 labeled phosphonium compound, Rb-82, Cu-64, F-18 FDG (all compounds which are taken up by the normal myocardium), and for Tc-99m pyrophosphate (PYP) (which localizes in myocardial infarcts). Dose estimates could not be generated for C-11 palmitate, but this compound was included in a comparison of myocardial retention times. For the I-123 labeled compounds, I-124 was included as a contaminant in generating the dose estimates. Radiation doses were lowest for Rb-82 (gonads 0.3 to 0.5 μGy/MBq, heart wall 15 μGy/MBq). Doses for the I-123 labeled fatty acids were similar to one another, with IPPA being the lowest (gonads 20 μGy/MBq, heart wall 15 μGy/MBq). Doses for Tc-99m PYP were also low (gonads 4 to 7 μGy/MBq, heart wall 4 μGy/MBq, skeleton 15 μGy/MBq). The desirability of these compounds is discussed briefly, considering half life, imaging mode and energy, and dosimetry, including a comparison of the effective whole body dose equivalents. 34 refs., 11 tabs

  2. If psychosis were cancer: a speculative comparison

    Science.gov (United States)

    Boden, Zoë; Newton, Elizabeth

    2017-01-01

    Recently, health policy in the UK has begun to engage with the concept of ‘parity of esteem’ between physical and mental healthcare. This has led one recent initiative to improve service provision for first episode psychosis, which aims to bring it into line with some of the principles underpinning good practice in cancer care. In this paper, we consider some of the metaphorical consequences of likening psychosis to cancer. While we find the comparison unhelpful for clinical purposes, we argue that it can be a helpful lens through which to examine service provision for psychosis in young people. Through this lens, specialist community-based services would appear to compare reasonably well. Inpatient care for young people with psychosis, on the other hand, suffers very badly by comparison with inpatient facilities for teenage cancer care. We note some of the many positive features of inpatient cancer care for young adults, and—drawing upon previous research on inpatient psychiatric care—observe that many of these are usually absent from mental health facilities. We conclude that this metaphor may be a helpful rhetorical device for communicating the lack of ‘parity of esteem’ between mental and physical healthcare. This inequity must be made visible in health policy, in commissioning, and in service provision. PMID:28559369

  3. Data for Room Fire Model Comparisons.

    Science.gov (United States)

    Peacock, Richard D; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system.

  4. YBYRÁ facilitates comparison of large phylogenetic trees.

    Science.gov (United States)

    Machado, Denis Jacob

    2015-07-01

    The number and size of tree topologies that are being compared by phylogenetic systematists is increasing due to technological advancements in high-throughput DNA sequencing. However, we still lack tools to facilitate comparison among phylogenetic trees with a large number of terminals. The "YBYRÁ" project integrates software solutions for data analysis in phylogenetics. It comprises tools for (1) topological distance calculation based on the number of shared splits or clades, (2) sensitivity analysis and automatic generation of sensitivity plots and (3) clade diagnoses based on different categories of synapomorphies. YBYRÁ also provides (4) an original framework to facilitate the search for potential rogue taxa based on how much they affect average matching split distances (using MSdist). YBYRÁ facilitates comparison of large phylogenetic trees and outperforms competing software in terms of usability and time efficiency, specially for large data sets. The programs that comprises this toolkit are written in Python, hence they do not require installation and have minimum dependencies. The entire project is available under an open-source licence at http://www.ib.usp.br/grant/anfibios/researchSoftware.html .

  5. Water gun vs air gun: A comparison

    Science.gov (United States)

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  6. Rapid comparison of properties on protein surface.

    Science.gov (United States)

    Sael, Lee; La, David; Li, Bin; Rustamov, Raif; Kihara, Daisuke

    2008-10-01

    The mapping of physicochemical characteristics onto the surface of a protein provides crucial insights into its function and evolution. This information can be further used in the characterization and identification of similarities within protein surface regions. We propose a novel method which quantitatively compares global and local properties on the protein surface. We have tested the method on comparison of electrostatic potentials and hydrophobicity. The method is based on 3D Zernike descriptors, which provides a compact representation of a given property defined on a protein surface. Compactness and rotational invariance of this descriptor enable fast comparison suitable for database searches. The usefulness of this method is exemplified by studying several protein families including globins, thermophilic and mesophilic proteins, and active sites of TIM beta/alpha barrel proteins. In all the cases studied, the descriptor is able to cluster proteins into functionally relevant groups. The proposed approach can also be easily extended to other surface properties. This protein surface-based approach will add a new way of viewing and comparing proteins to conventional methods, which compare proteins in terms of their primary sequence or tertiary structure.

  7. Social comparison, personal relative deprivation, and materialism.

    Science.gov (United States)

    Kim, Hyunji; Callan, Mitchell J; Gheorghiu, Ana I; Matthews, William J

    2017-06-01

    Across five studies, we found consistent evidence for the idea that personal relative deprivation (PRD), which refers to resentment stemming from the belief that one is deprived of deserved outcomes compared to others, uniquely contributes to materialism. In Study 1, self-reports of PRD positively predicted materialistic values over and above socioeconomic status, personal power, self-esteem, and emotional uncertainty. The experience of PRD starts with social comparison, and Studies 2 and 3 found that PRD mediated the positive relation between a tendency to make social comparisons of abilities and materialism. In Study 4, participants who learned that they had less (vs. similar) discretionary income than people like them reported a stronger desire for more money relative to donating more to charity. In Study 5, during a windfall-spending task, participants higher in PRD spent more on things they wanted relative to other spending categories (e.g., paying off debts). © 2016 The Authors. British Journal of Social Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.

  8. Data for Room Fire Model Comparisons

    Science.gov (United States)

    Peacock, Richard D.; Davis, Sanford; Babrauskas, Vytenis

    1991-01-01

    With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system. PMID:28184121

  9. Economic comparison of fusion fuel cycles

    International Nuclear Information System (INIS)

    Brereton, S.J.; Kazimi, M.S.

    1987-01-01

    The economics of the DT, DD, and DHe fusion fuel cycles are evaluated by comparison on a consistent basis. The designs for the comparison employ HT-9 structure and helium coolant; liquid lithium is used as the tritium breeding material for the DT fuel cycle. The reactors are pulsed, superconducting tokamaks, producing 1200 MW of electric power. The DT and DD designs scan a range of values of plasma beta, assuming first stability scaling laws. The results indicate that on a purely economic basis, the DT fuel cycle is superior to both of the advanced fuel cycles. Geometric factors, materials limitations, and plasma beta were seen to have an impact on the Cost of Electricity (COE). The economics for the DD fuel cycle are more strongly affected by these parameters than is the DT fuel cycle. Fuel costs are a major factor in determining the COE for the DHe fuel cycle. Based on costs directly attributable to the fuel cycle, the DT fuel cycle appears most attractive. Technological advances, improved understanding of physics, or strides in advanced energy conversion schemes may result in altering the economic ranking of the fuel cycles indicated here. 7 refs., 6 figs., 2 tabs

  10. Comparison between four dissimilar solar panel configurations

    Science.gov (United States)

    Suleiman, K.; Ali, U. A.; Yusuf, Ibrahim; Koko, A. D.; Bala, S. I.

    2017-12-01

    Several studies on photovoltaic systems focused on how it operates and energy required in operating it. Little attention is paid on its configurations, modeling of mean time to system failure, availability, cost benefit and comparisons of parallel and series-parallel designs. In this research work, four system configurations were studied. Configuration I consists of two sub-components arranged in parallel with 24 V each, configuration II consists of four sub-components arranged logically in parallel with 12 V each, configuration III consists of four sub-components arranged in series-parallel with 8 V each, and configuration IV has six sub-components with 6 V each arranged in series-parallel. Comparative analysis was made using Chapman Kolmogorov's method. The derivation for explicit expression of mean time to system failure, steady state availability and cost benefit analysis were performed, based on the comparison. Ranking method was used to determine the optimal configuration of the systems. The results of analytical and numerical solutions of system availability and mean time to system failure were determined and it was found that configuration I is the optimal configuration.

  11. Final report on CCM key comparison CCM.D-K2: Comparison of liquid density standards

    Science.gov (United States)

    Bettin, Horst; Jacques, Claude; Zelenka, Zoltán; Fujii, Ken-ichi; Kuramoto, Naoki; Chang, Kyung-Ho; Lee, Yong Jae; Becerra, Luis Omar; Domostroeva, Natalia

    2013-01-01

    The results are presented of the key comparison CCM.D-K2 that covered the density measurements of four liquids: the density of water at 20 °C, of pentadecane at 15 °C, 20 °C, 40 °C and 60°C, of tetrachloroethlyene at 5 °C and 20 °C and of a viscous oil at 20 °C. Seven national metrology institutes measured the densities at atmospheric pressure by hydrostatic weighing of solid density standards in the time interval from 27 April 2004 to 28 June 2004. Since the participants were asked not to include components for a possible drift or inhomogeneity of the liquid in their uncertainty budget, these uncertainty contributions are investigated for the final evaluation of the data. For this purpose, results of stability and homogeneity measurements of the pilot laboratory are used. The participants decided not to include a possible drift of the liquid's density since no significant drift could be detected, and the influence of the drift and its uncertainty are negligible. Similarly, the inhomogeneity of the water and pentadecane samples is not significant and has no influence on the evaluation. Thus, it was neglected. Only the inhomogeneities of tetrachloroethylene and of the viscous oil were significant. Consequently, they were included in the evaluation. With one or two exceptions, the results show good agreement among the participants. Only in the case of water are the results clearly discrepant. The key comparison reference values were calculated by the weighted mean (taking into account a small correlation between two participants) in the case of consistent results. Otherwise the Procedure B of Cox was used. The expanded uncertainties of all reference densities are below 1 × 10-5 in relative terms. This satisfies the needs of all customers who wish to calibrate or check liquid density measuring instruments such as oscillation-type density meters. The comparison fully supports the calibration measurement capabilities table in the BIPM key comparison database

  12. SUPPLEMENTARY COMPARISON: EUROMET.L-S10 Comparison of squareness measurements

    Science.gov (United States)

    Mokros, Jiri

    2005-01-01

    The idea of performing a comparison of squareness resulted from the need to review the MRA Appendix C, Category 90° square. At its meeting in October 1999 (in Prague) it was decided upon a first comparison of squareness measurements in the framework of EUROMET, numbered #570, starting in 2000, with the Slovak Institute of Metrology (SMU) as the pilot laboratory. During the preparation stage of the project, it was agreed that it should be submitted as a EUROMET supplementary comparison in the framework of the Mutual Recognition Arrangement (MRA) of the Metre Convention and would boost confidence in calibration and measurement certificates issued by the participating national metrology institutes. The aim of the comparison of squareness measurement was to compare and verify the declared calibration measurement capabilities of participating laboratories and to investigate the effect of systematic influences in the measurement process and their elimination. Eleven NMIs from the EUROMET region carried out this project. Two standards were calibrated: granite squareness standard of rectangular shape, cylindrical squareness standard of steel with marked positions for the profile lines. The following parameters had to be calibrated: granite squareness standard: interior angle γB between two lines AB and AC (envelope - LS regression) fitted through the measured profiles, and/or granite squareness standard: interior angle γLS between two LS regression lines AB and AC fitted through the measured profiles, cylindrical squareness standard: interior angles γ0°, γ90°, γ180°, γ270° between the LS regression line fitted through the measurement profiles at 0°, 90°, 180°, 270° and the envelope plane of the basis (resting on a surface plate), local LS straightness deviation for all measured profiles (2 and 4) of both standards. The results of the comparison are the deviations of profiles and angles measured by the individual NMIs from the reference values. These resulted

  13. The efficiency of similarity-focused comparisons in person perception.

    Science.gov (United States)

    Corcoran, Katja

    2013-01-01

    Comparison processes are ubiquitous in person perception. Comparative thinking can follow two routes: People either search for similarities or for dissimilarities while comparing. Which of these two routes is more efficient? Previous research indicates that people could compare two geometrical figures faster if they focused on similarities rather than dissimilarities. I examine comparisons of people and measure the consumption of cognitive resources as indicator for efficiency. The results confirm an efficiency-advantage of similarity-focused comparisons for social stimuli.

  14. Loss aversion, social comparison and physical abilities at younge age

    OpenAIRE

    Nakamoto, Yasuhiro; Sato, Masayuki

    2011-01-01

    We examine the relationship between competitive behavior and social comparison where in this paper competitive behavior is measured by physical ability performance. In particular, by incorporating social comparison into prospect theory, we directly estimate the degree of loss aversion with social comparison, a concept we term `ALJ' (Avoiding Loss relative to the Joneses). Our main findings are as follows: (i) the estimated value function is refracted at another's gain and the average estimate...

  15. A general comparison theorem for backward stochastic differential equations

    OpenAIRE

    Cohen, Samuel N.; Elliott, Robert J.; Pearce, Charles E. M.

    2010-01-01

    A useful result when dealing with backward stochastic differential equations is the comparison theorem of Peng (1992). When the equations are not based on Brownian motion, the comparison theorem no longer holds in general. In this paper we present a condition for a comparison theorem to hold for backward stochastic differential equations based on arbitrary martingales. This theorem applies to both vector and scalar situations. Applications to the theory of nonlinear expectat...

  16. A Modified Image Comparison Algorithm Using Histogram Features

    OpenAIRE

    Al-Oraiqat, Anas M.; Kostyukova, Natalya S.

    2018-01-01

    This article discuss the problem of color image content comparison. Particularly, methods of image content comparison are analyzed, restrictions of color histogram are described and a modified method of images content comparison is proposed. This method uses the color histograms and considers color locations. Testing and analyzing of based and modified algorithms are performed. The modified method shows 97% average precision for a collection containing about 700 images without loss of the adv...

  17. GODAE Inter-Comparisons in the Tasman and Coral Seas

    Science.gov (United States)

    2012-08-01

    and salinity. All have their strengths and weaknesses, and each system out-performs all others in one aspect or another. With few exceptions, all... Auckland and Fiji (Fig 1), was occupied during the inter- comparison period. The observed T section from this line is shown in Fig 6a. Comparisons of T...has certain strengths and weaknesses. Inter-comparisons are regarded as valuable exer- cises that provide important insights into the ocean forecast

  18. Comparison of multiplex reverse transcription-PCR-enzyme ...

    African Journals Online (AJOL)

    Comparison of multiplex reverse transcription-PCR-enzyme hybridization assay with immunofluorescence techniques for the detection of four viral respiratory pathogens in pediatric community acquired pneumonia.

  19. Estimation of radiation exposure of retrospective gated and prospective triggered 128-slice triple-rule-out CT angiography

    International Nuclear Information System (INIS)

    Ketelsen, Dominik; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Tsiflikas, Ilias; Kaempf, Michael; Claussen, Claus D; Heuschmid, Martin; Buchgeister, Markus

    2011-01-01

    Background: CT has become an important role in the differential diagnosis of acute chest pain to exclude an aortic dissection, pulmonary embolism and acute coronary artery syndrome. However, the additional radiation exposure is a cause of concern and dose saving strategies should be applied, if possible. Purpose: To estimate effective dose of retrospective gated and prospective ECG-triggered triple-rule-out computed tomography angiography (TRO-CTA). Material and Methods: An Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a 128-slice single source scanner. The following scan parameters were used (retrospective ECG-gated): 120 kV, 190 mAs/rot., collimation 128x0.6 mm, rotation time 0.3 s. Protocols with a simulated heart rate (HR) of 60 and 100 bpm were performed using the standard ECG-pulsing as well as MinDose. Additionally, a prospective triggered TRO-CTA was acquired (HR 60 bpm). Results: The estimated effective dose of retrospective ECG-gated TRO-CTA ranged from 7.4-13.4 mSv and from 10.1-17.5 mSv for men and women, respectively. Due to radiosensitive breast tissue, women received a significant increased effective dose of up to 64.7% ± 0.03% (p = 0.028) compared to men. MinDose reduces radiation exposure of up to 33.0% ± 6.5% in comparison to standard ECG-pulsing (p < 0.001). The effective dose increased significantly with lower heart rates (p < 0.001). Prospective ECG-triggered TRO-CTA showed an effective dose of 5.9 mSv and 8.2 mSv for men and women, respectively. Compared to retrospective ECG-gated TRO-CTA a significant dose reduction was observed (p < 0.001). Conclusion: Due to the significant different dose exposure, scan protocols should be specifically adapted in a patient- and problem-oriented manner

  20. Estimation of radiation exposure of retrospective gated and prospective triggered 128-slice triple-rule-out CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Fenchel, Michael; Thomas, Christoph; Boehringer, Nadine; Tsiflikas, Ilias; Kaempf, Michael; Claussen, Claus D; Heuschmid, Martin (Dept. of Diagnostic and Interventional Radiology, Univ. Hospital Tuebingen, Tuebingen (Germany)), email: dominik.ketelsen@med.uni-tuebingen.de; Buchgeister, Markus (Depts. of Radiotherapy and Radiooncology, Univ. Hospital Tuebingen, Tuebingen (Germany))

    2011-09-15

    Background: CT has become an important role in the differential diagnosis of acute chest pain to exclude an aortic dissection, pulmonary embolism and acute coronary artery syndrome. However, the additional radiation exposure is a cause of concern and dose saving strategies should be applied, if possible. Purpose: To estimate effective dose of retrospective gated and prospective ECG-triggered triple-rule-out computed tomography angiography (TRO-CTA). Material and Methods: An Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a 128-slice single source scanner. The following scan parameters were used (retrospective ECG-gated): 120 kV, 190 mAs/rot., collimation 128x0.6 mm, rotation time 0.3 s. Protocols with a simulated heart rate (HR) of 60 and 100 bpm were performed using the standard ECG-pulsing as well as MinDose. Additionally, a prospective triggered TRO-CTA was acquired (HR 60 bpm). Results: The estimated effective dose of retrospective ECG-gated TRO-CTA ranged from 7.4-13.4 mSv and from 10.1-17.5 mSv for men and women, respectively. Due to radiosensitive breast tissue, women received a significant increased effective dose of up to 64.7% +- 0.03% (p = 0.028) compared to men. MinDose reduces radiation exposure of up to 33.0% +- 6.5% in comparison to standard ECG-pulsing (p < 0.001). The effective dose increased significantly with lower heart rates (p < 0.001). Prospective ECG-triggered TRO-CTA showed an effective dose of 5.9 mSv and 8.2 mSv for men and women, respectively. Compared to retrospective ECG-gated TRO-CTA a significant dose reduction was observed (p < 0.001). Conclusion: Due to the significant different dose exposure, scan protocols should be specifically adapted in a patient- and problem-oriented manner

  1. Code comparison for accelerator design and analysis

    International Nuclear Information System (INIS)

    Parsa, Z.

    1988-01-01

    We present a comparison between results obtained from standard accelerator physics codes used for the design and analysis of synchrotrons and storage rings, with programs SYNCH, MAD, HARMON, PATRICIA, PATPET, BETA, DIMAD, MARYLIE and RACE-TRACK. In our analysis we have considered 5 (various size) lattices with large and small angles including AGS Booster (10/degree/ bend), RHIC (2.24/degree/), SXLS, XLS (XUV ring with 45/degree/ bend) and X-RAY rings. The differences in the integration methods used and the treatment of the fringe fields in these codes could lead to different results. The inclusion of nonlinear (e.g., dipole) terms may be necessary in these calculations specially for a small ring. 12 refs., 6 figs., 10 tabs

  2. Insights from Human/Mouse genome comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Pennacchio, Len A.

    2003-03-30

    Large-scale public genomic sequencing efforts have provided a wealth of vertebrate sequence data poised to provide insights into mammalian biology. These include deep genomic sequence coverage of human, mouse, rat, zebrafish, and two pufferfish (Fugu rubripes and Tetraodon nigroviridis) (Aparicio et al. 2002; Lander et al. 2001; Venter et al. 2001; Waterston et al. 2002). In addition, a high-priority has been placed on determining the genomic sequence of chimpanzee, dog, cow, frog, and chicken (Boguski 2002). While only recently available, whole genome sequence data have provided the unique opportunity to globally compare complete genome contents. Furthermore, the shared evolutionary ancestry of vertebrate species has allowed the development of comparative genomic approaches to identify ancient conserved sequences with functionality. Accordingly, this review focuses on the initial comparison of available mammalian genomes and describes various insights derived from such analysis.

  3. Data evaluation and code comparison activities

    International Nuclear Information System (INIS)

    Itikawa, Yukikazu; Takagi, Hidekazu; Nakamura, Yoshiharu; Imai, Makoto; Sasaki, Akira

    2013-01-01

    In atomic and molecular data base, intolerable numerical differences beyond error margin are found among some papers resulted from measurements or calculations even for the same collision processes. These differences spoil the reliability of the data base. This report describes the data evaluation for atomic and molecular data promoted by IAEA cooperated with other institutes, which Japanese researchers collaborate with. The reaction cross sections calculated numerically are evaluated for the collisions between electrons and molecular ions of H 2 + and HeH + . The application of an electron swarm parameter was shown for the evaluation and determination of the collision cross sections between electrons and molecules. In order to complete higher precision of atomic codes and a collisional-radiative model, IAEA held the workshop for the code comparison of the nonlocal thermodynamic equilibrium. (Y. Kazumata)

  4. Comparison of historical documents for writership

    Science.gov (United States)

    Ball, Gregory R.; Pu, Danjun; Stritmatter, Roger; Srihari, Sargur N.

    2010-01-01

    Over the last century forensic document science has developed progressively more sophisticated pattern recognition methodologies for ascertaining the authorship of disputed documents. These include advances not only in computer assisted stylometrics, but forensic handwriting analysis. We present a writer verification method and an evaluation of an actual historical document written by an unknown writer. The questioned document is compared against two known handwriting samples of Herman Melville, a 19th century American author who has been hypothesized to be the writer of this document. The comparison led to a high confidence result that the questioned document was written by the same writer as the known documents. Such methodology can be applied to many such questioned documents in historical writing, both in literary and legal fields.

  5. Terrestrial magnetosphere and comparison with Jupiter's

    International Nuclear Information System (INIS)

    Michel, F.C.

    1974-01-01

    A review of the characteristics of Jupiter's magnetosphere, with comparisons to the earth's is given. Radio observations of Jupiter indicate that energetic electrons are trapped in its magnetic field. The interaction of the trapped radiation with the satellite Io and the centrifugal instability of Jupiter's magnetosphere are discussed. Jupiter's outer magnetosphere is constantly accreting plasma at an uncertain rate. Various mechanisms for supplying ions to the outer magnetosphere are discussed, including: gravitational and centrifugal forces acting on corotating particles; field-line diffusion; photoelectron injection; excitation by Io or other satellites; and viscous interaction with the solar wind. The over-all morphology of the Jovian magnetosphere seems to be highly distorted by centrifugal forces and is easily compressed or deflected by the solar wind

  6. Tests and comparisons of gravity models.

    Science.gov (United States)

    Marsh, J. G.; Douglas, B. C.

    1971-01-01

    Optical observations of the GEOS satellites were used to obtain orbital solutions with different sets of geopotential coefficients. The solutions were compared before and after modification to high order terms (necessary because of resonance) and were then analyzed by comparing subsequent observations with predicted trajectories. The most important source of error in orbit determination and prediction for the GEOS satellites is the effect of resonance found in most published sets of geopotential coefficients. Modifications to the sets yield greatly improved orbits in most cases. The results of these comparisons suggest that with the best optical tracking systems and gravity models, satellite position error due to gravity model uncertainty can reach 50-100 m during a heavily observed 5-6 day orbital arc. If resonant coefficients are estimated, the uncertainty is reduced considerably.

  7. Blanket comparison and selection study. Volume I

    International Nuclear Information System (INIS)

    1983-10-01

    The objectives of the Blanket Comparison and Selection Study (BCSS) can be stated as follows: (1) Define a small number (approx. 3) of blanket design concepts that should be the focus of the blanket R and D program. A design concept is defined by the selection of all materials (e.g., breeder, coolant, structure and multiplier) and other major characteristics that significantly influence the R and D requirements. (2) Identify and prioritize the critical issues for the leading blanket concepts. (3) Provide the technical input necessary to develop a blanket R and D program plan. Guidelines for prioritizing the R and D requirements include: (a) critical feasibility issues for the leading blanket concepts will receive the highest priority, and (b) for equally important feasibility issues, higher R and D priority will be given to those that require minimum cost and short time

  8. COMPARISON OF TWO STRUCTURE AND MOTION STRATEGIES

    Directory of Open Access Journals (Sweden)

    R. Roncella

    2012-09-01

    Full Text Available Automatic orientation of image sequences in close range photogrammetry is becoming more and more important, not least to maintain a degree of competitiveness with other survey techniques, such as laser scanning. The objective of this paper is to compare two Structure from Motion (SFM strategies. The previous strategy has been used at our Department for some years already in a wide range of projects and is based on the Harris operator and the fundamental matrix plus the trifocal tensor estimation to filter out the outliers. While it has in most cases performed satisfactorily, the percentage of accepted matches is generally smaller than expected; sometimes this leads to failure of the successful estimation of the trifocal tensor. The second one has only recently been implemented and is still under testing; it is based on the SURF operator and the 5-point relative orientation algorithm. The paper will show a comparison between the two strategies on a series of test cases.

  9. Model Comparison for Electron Thermal Transport

    Science.gov (United States)

    Moses, Gregory; Chenhall, Jeffrey; Cao, Duc; Delettrez, Jacques

    2015-11-01

    Four electron thermal transport models are compared for their ability to accurately and efficiently model non-local behavior in ICF simulations. Goncharov's transport model has accurately predicted shock timing in implosion simulations but is computationally slow and limited to 1D. The iSNB (implicit Schurtz Nicolai Busquet electron thermal transport method of Cao et al. uses multigroup diffusion to speed up the calculation. Chenhall has expanded upon the iSNB diffusion model to a higher order simplified P3 approximation and a Monte Carlo transport model, to bridge the gap between the iSNB and Goncharov models while maintaining computational efficiency. Comparisons of the above models for several test problems will be presented. This work was supported by Sandia National Laboratory - Albuquerque and the University of Rochester Laboratory for Laser Energetics.

  10. Survey and comparison of automated UT systems

    International Nuclear Information System (INIS)

    Neeley, V.I.; Avioli, M.J.

    1988-01-01

    In the past decade, the limitations of manual UT inspections have become more severe and adverse. Perhaps the best evidence of this has been the problem of intergranular stress corrosion cracking (IGSCC) in boiling water reactors (BWR). The onset of this problem clearly showed that better and more sophisticated UT inspection methods must be developed to assure the industry that an appropriate level of inspection integrity could be maintained. While automated UT inspection systems have been under development for some time, this event certainly spurred this activity and has resulted in a variety of commercial systems. The intent of this project, sponsored by EPRI, is to develop a utility engineer's 'Buyer guide' to automated UT systems. Comparison of different automated UT systems along with results of questionnaires on manual UT versus automated UT costs and effectiveness are reviewed. (author)

  11. Adaptive Robot Control – An Experimental Comparison

    Directory of Open Access Journals (Sweden)

    Francesco Alonge

    2012-11-01

    Full Text Available This paper deals with experimental comparison between stable adaptive controllers of robotic manipulators based on Model Based Adaptive, Neural Network and Wavelet -Based control. The above control methods were compared with each other in terms of computational efficiency, need for accurate mathematical model of the manipulator and tracking performances. An original management algorithm of the Wavelet Network control scheme has been designed, with the aim of constructing the net automatically during the trajectory tracking, without the need to tune it to the trajectory itself. Experimental tests, carried out on a planar two link manipulator, show that the Wavelet-Based control scheme, with the new management algorithm, outperforms the conventional Model-Based schemes in the presence of structural uncertainties in the mathematical model of the robot, without pre-training and more efficiently than the Neural Network approach.

  12. Comparison of Hippocampal Volume in Dementia Subtypes

    International Nuclear Information System (INIS)

    Vijayakumar, Avinash; Vijayakumar, Abhishek

    2012-01-01

    Aims. To examine the relationship between different types of dementia and hippocampal volume. Methods. Hippocampal volume was measured using FL3D sequence magnetic resonance imaging in 26 Alzheimer's, vascular dementia, mixed dementia, and normal pressure hydrocephalus patients and 15 healthy controls and also hippocampal ratio, analyzed. Minimental scale was used to stratify patients on cognitive function impairments. Results. Hippocampal volume and ratio was reduced by 25% in Alzheimer's disease, 21% in mixed dementia, 11% in vascular dementia and 5% in normal pressure hydrocephalus in comparison to control. Also an asymmetrical decrease in volume of left hippocampus was noted. The severity of dementia increased in accordance to decreasing hippocampal volume. Conclusion. Measurement in hippocampal volume may facilitate in differentiating different types of dementia and in disease progression. There was a correlation between hippocampal volume and severity of cognitive impairment

  13. Thermoeconomic comparison of industrial heat pumps

    DEFF Research Database (Denmark)

    Ommen, Torben Schmidt; Markussen, Christen Malte; Reinholdt, L.

    2011-01-01

    Four natural working fluids in various heat pump cycles are expected to cover the heating range between 50oC and 150°C. The different thermodynamic cycles are the Condensing Vapour, Transcritical and Compression/Absorption. As the considered technologies have significant differences in application......, limitations and design, a generic comparison is used. To establish the optimal individual temperature range of operation, a thermoeconomic evaluation is performed, with heat price as the decision parameter. Each individual heat pump is favourable in specific temperature intervals, which will vary according...... to the temperature lift between sink and source. At temperature lifts below 30°C the entire temperature range is covered. Exceeding this temperature lift, the range of sink temperatures is not completely covered above 125°C. Three of the heat pumps prove very cost competitive when compared to heating with natural...

  14. Spread and Liquidity Issues: A markets comparison

    Directory of Open Access Journals (Sweden)

    Strašek Sebastjan

    2016-03-01

    Full Text Available The financial crises are closely connected with spread changes and liquidity issues. After defining and addressing spread considerations, we research in this paper the topic of liquidity issues in times of economic crisis. We analyse the liquidity effects as recorded on spreads of securities from different markets. We stipulate that higher international risk aversion in times of financial crises coincides with widening security spreads. The paper then introduces liquidity as a risk factor into the standard value-at-risk framework, using GARCH methodology. The comparison of results of these models suggests that the size of the tested markets does not have a strong effect on the models. Thus, we find that spread analysis is an appropriate tool for analysing liquidity issues during a financial crisis.

  15. The mutual recognition arrangement and primary standard dosimetry laboratory comparisons

    International Nuclear Information System (INIS)

    Allisy-Roberts, P.J.; Burns, D.T.

    2002-01-01

    Full text: The majority of the Member States of the Metre Convention have signed an arrangement for the mutual recognition (MRA) of national measurement standards and calibration and measurement capabilities (CMCs). Part of the MRA involves an open access database of CMCs that in turn need to be supported by key and supplementary comparisons of national standards. This paper outlines the MRA, describing the comparisons of national primary standards in the field of dosimetry that support the claims of the CMCs in the key comparison database (KCDB). The MRA was drawn up by the International Committee for Weights and Measures (Comite International des Poids et Mesures CIPM) and was signed at a meeting held in Paris on 14 October 1999 by the directors of the national metrology institutes (NMIs) of thirty-eight Member States of the Metre Convention and representatives of two international organizations. Since that date, the directors of the NMIs of several other Member States and nine Associates of the General Conference (Conference Generale des Poids et Mesures CGPM) have also signed the MRA. The metrological objectives of the MRA are to establish the degree of equivalence of national measurement standards maintained by NMIs and thus provide the basis for the mutual recognition of calibration and measurement certificates issued by NMIs. The NMIs provide the traceability to the international system of units (SI) required for these services and thus mutual recognition of the capabilities of the NMIs is a prerequisite for the mutual recognition of the metrology services of countries in general. The objectives of the MRA are achieved through a process of: (a) international comparisons of measurements, known as key comparisons (b) supplementary international comparisons of measurements, and (c) quality systems and demonstrations of competence by the NMIs. The outcome of the MRA is a determination of the degrees of equivalence of national standards and a set of statements of

  16. Comparison of hydrocephalus appearance at spinaldysraphia.

    Science.gov (United States)

    Elshani, Besnik; Lenjani, Basri

    2013-01-01

    Congenital malformation of spinal dysraphism followed by hydrocephalus are phenomenon reveals during intrauterine child growth. Prime objective of this work was to present Comparison of hydrocephalus appearance at spinal dysraphism respectively at its meningocele and myelomeningocele forms in Neurosurgery Clinic in UCC in Prishtina. It is perfected with retrospective and prospective method precisely of its epidemiologic part summarizing notices from patients' histories which in 2000-2006 are hospitalized in Neurosurgery Clinic from (QFLPK)--Pediatric Clinic and Children Box (Department)--Gynecology Clinic and from Sanitary Regional Center throughout Kosova. Our study objects were two groups, as the first group 90 patients with spinal dysraphism where neurosurgery operations were done and classified types of dysraphism. At myelomeningocele hydrocephalus has dominated and in a percent of appearance and as acute of its active form was 97% of hydrocephalus form where subjected to cerebrospinal liquid derivation with ventriculo -peritoneal shunt in comparison with meningocele we do not have involvation of spinal nerve element, hydrocephalus takes active form with intervention indication in 60% of cases. Reflection in shown deficit aspect is totally different at myelomeningoceles where lower paraplegia dominate more than paraparesis. The second patient operative technique developed by hydrocephalus with neurosurgical intervention indication has to do with placing of (VP) ventriculo- peritoneal system (shant) at myelomeningoceles with hydrocephalus 58 cases and 12 cases meningoceles with hydrocephalus. Post operative meningitis (shant meningitis): from 70 operated cases of hydrocephalus with spinal dysraphism shunts complications from all types are just cases. Finally that appearance of hydrocephalus compared at spinal dysraphism dominate at myellomeningoceles as in notice time aspect, it is persisting and further acute, with vital motivation for neurosurgical

  17. Proton dosimetry comparison involving ionometry and calorimetry

    International Nuclear Information System (INIS)

    Delacroix, Sabine; Bridier, Andre; Mazal, Alexandre; Daures, Josiane; Ostrowsky, Aime; Nauraye, Catherine; Kacperek, Andre; Vynkier, Stephane; Brassard, Nicole; Habrand, Jean-Louis

    1997-01-01

    A comparison of the absorbed dose to tissue determined by various ionization chambers, Faraday cups, and an A-150 plastic calorimeter was performed in the 200 MeV proton beam of Orsay, France. Four European proton-therapy centers (Clatterbridge, UK, Louvain la Neuve, Belgium, and Nice and Orsay, France) participated in the comparison. An agreement of better than 1% was observed in the absorbed dose to A-150 measured with the different chambers of the participating groups. The mean ratio of the absorbed dose to A-150 determined with the calorimeter to that determined by the different ionization chambers in the different irradiation conditions was found to be 0.952 ± 0.007 [1 standard deviation (SD)] according to the code of practice used by all the participating centers, based on Janni's tables of stopping powers and a value of 35.2 J/Coulomb for (W air /e) p . A better agreement in the mean ratio calorimeter/chamber, 0.985 ± 0.007 (1 SD) is observed when using the proton stopping power ratio values recently published by the International Commission on Radiation Units and Measurements in Report no. 49. The mean ratio of these doses determined in accordance with the American Association of Physicists in Medicine protocol and using the new recommended stopping power tables becomes 1.002 ± 0.007 (1 SD). Two Faraday cups agree in measured charge to within 0.8%; however, the calculation of dose is underestimated by up to 17%; compared with ion chamber measurements and seems to be very sensitive to measurement conditions, particularly to the distance to the collimator

  18. INTERNATIONAL COMPARISONS IN THE IMPROVEMENT OF EDUCATION

    Directory of Open Access Journals (Sweden)

    Hebert David G.

    2012-12-01

    Full Text Available Imperfections - such as inequality and inefficiency of learning - are perennial problems for education despite a diversity of foundations on which national systems are established, which range from the idealistic vision of fostering a utopian society to the utilitarian objective of producing skilled workers capable of engendering economic growth. Despite sharing many common conditions and fundamental values, educators rarely learn valuable lessons from the successes and failures of highly relevant initiatives in distant nations. This problem may be attributed to several factors, not the least of which includes the entrenchment of local traditions and ethnocentric assumptions, but surely the quality and relevance of international-comparative research - and the way its results are disseminated - are issues that must also be taken into careful consideration. What are the unique lessons to be learned from international comparisons, and what are the prospective risks for how such comparisons may be misinterpreted and misused in educational settings? How can international comparative research be made more relevant, with tangible applications that may be recognized and effectively used by school teachers? How can international comparative education meaningfully examine subjects beyond the reach of standardized testing, in such domains as the fostering of creativity, talent, and ethical sensibilities, for example? These themes will be presented through discussion of both research findings and anecdotes from the personal experience of working for universities on four continents. Specific topics will include the challenges of accounting for conceptual equivalency and representing cultural differences, sampling and generalizability, reconciling the diverging aims of economic, anthropological, sociological, and psychological research, as well as grappling with the ambivalent discourse of globalization, multiculturalism, post-colonialism, and other social

  19. Intercode comparison of SBO scenario for AHWR

    International Nuclear Information System (INIS)

    Srivastava, A.; Kumar, Rajesh; Chatterjee, B.; Vijayan, P.K.

    2015-01-01

    This paper outlines the assessment of station blackout scenario for AHWR using last version of the French best estimate computer code CATHARE2/V2.5 2 and its comparison with RELAP5/mod3.2 findings. First, it explains the modelling of main heat transport system of AHWR and isolation Condenser loop along with GDWP in CATHARE2 followed by thermal hydraulic safety assessment of station blackout scenario and comparison of predictions with RELAP5 findings. The proposed Advanced Heavy Water Reactor is a 920 MWth Thorium based vertical pressure tube type boiling light water cooled and heavy water moderated reactor. One of the important passive design features of this reactor is that the heat removal is achieved through natural circulation of primary coolant at all allowed power levels with no primary coolant pumps.The prolonged SBO has been analyzed for AHWR using best estimate code CATHARE and results are compared with already available results of RELAP5 code. The ICs are able to remove decay heat with the help of GDWP and maintain core temperatures well with-in the limit. Decay heat is removed passively by GDWP initially by sensible heating and later by boil off as seen in long term calculation done with RELAP5. It has been found in that analysis, IC system is capable to remove decay heat for more than 7 days. The decay heat removal through IC path along with passive moderator and end shield cooling keeps the integrity of different system and maintains the core temperature well below the acceptance limit

  20. Dynamic programming algorithms for biological sequence comparison.

    Science.gov (United States)

    Pearson, W R; Miller, W

    1992-01-01

    Efficient dynamic programming algorithms are available for a broad class of protein and DNA sequence comparison problems. These algorithms require computer time proportional to the product of the lengths of the two sequences being compared [O(N2)] but require memory space proportional only to the sum of these lengths [O(N)]. Although the requirement for O(N2) time limits use of the algorithms to the largest computers when searching protein and DNA sequence databases, many other applications of these algorithms, such as calculation of distances for evolutionary trees and comparison of a new sequence to a library of sequence profiles, are well within the capabilities of desktop computers. In particular, the results of library searches with rapid searching programs, such as FASTA or BLAST, should be confirmed by performing a rigorous optimal alignment. Whereas rapid methods do not overlook significant sequence similarities, FASTA limits the number of gaps that can be inserted into an alignment, so that a rigorous alignment may extend the alignment substantially in some cases. BLAST does not allow gaps in the local regions that it reports; a calculation that allows gaps is very likely to extend the alignment substantially. Although a Monte Carlo evaluation of the statistical significance of a similarity score with a rigorous algorithm is much slower than the heuristic approach used by the RDF2 program, the dynamic programming approach should take less than 1 hr on a 386-based PC or desktop Unix workstation. For descriptive purposes, we have limited our discussion to methods for calculating similarity scores and distances that use gap penalties of the form g = rk. Nevertheless, programs for the more general case (g = q+rk) are readily available. Versions of these programs that run either on Unix workstations, IBM-PC class computers, or the Macintosh can be obtained from either of the authors.

  1. A CFD code comparison of wind turbine wakes

    DEFF Research Database (Denmark)

    Laan, van der, Paul Maarten; Storey, R. C.; Sørensen, Niels N.

    2014-01-01

    A comparison is made between the EllipSys3D and SnS CFD codes. Both codes are used to perform Large-Eddy Simulations (LES) of single wind turbine wakes, using the actuator disk method. The comparison shows that both LES models predict similar velocity deficits and stream-wise Reynolds-stresses fo...

  2. Technical recommendations for bilateral comparison in diagnosis radiology: part 2

    International Nuclear Information System (INIS)

    Peixoto, J.G.P.; Almeida, C.E.V. de

    2015-01-01

    The conventional radiology (≈70%), mammography(≈4%) and Computer Tomography (≈2%) will be in charge of this bilateral comparison. We could found the users ionization chambers, reference and radiations conditions, agenda and the comparison budget. The partial results will be presentation at metrology and medical physics congress. (author)

  3. Comparison of asphere measurements by tactile and optical metrological instruments

    NARCIS (Netherlands)

    Bergmans, R.H.; Nieuwenkamp, H.J.; Kok, G.J.P.; Blobel, G.; Nouira, H.; Küng, A.; Baas, M.; Voert, M.J.A. te; Baer, G.; Stuerwald, S.

    2015-01-01

    A comparison of topography measurements of aspherical surfaces was carried out by European metrology institutes, other research institutes and a company as part of an European metrology research project. In this paper the results of this comparison are presented. Two artefacts were circulated, a

  4. Design and Comparison Direct Torque Control Techniques for Induction Motors

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Kazmierkowski, Marian P.; Zelechowski, Marcin

    2005-01-01

    In this paper a comparison of two significant control methods of induction motor are presented. The first one is a classical Direct Torque and Flux Control (DTC) and is compared with a scheme, which uses Space Vector Modulator (DTC-SVM). A comparison in respect to dynamic and steady state...

  5. On Comparison Theorems for Conformable Fractional Differential Equations

    Directory of Open Access Journals (Sweden)

    Mehmet Zeki Sarikaya

    2016-10-01

    Full Text Available In this paper the more general comparison theorems for conformable fractional differential equations is proposed and tested. Thus we prove some inequalities for conformable integrals by using the generalization of Sturm's separation and Sturm's comparison theorems. The results presented here would provide generalizations of those given in earlier works. The numerical example is also presented to verify the proposed theorem.

  6. 30 CFR 206.155 - Accounting for comparison.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Accounting for comparison. 206.155 Section 206... MANAGEMENT PRODUCT VALUATION Federal Gas § 206.155 Accounting for comparison. (a) Except as provided in... the gas the residue gas is not sold pursuant to an arm's-length contract, the value, for royalty...

  7. COMPARISON THEOREMS AND APPLICATIONS OF OSCILLATION OF NEUTRAL DIFFERENTIAL EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    燕居让

    1991-01-01

    We first establish comparison theorems of the oscillation for a higher-order neutral delaydifferential equation. By these comparison theorems, the criterion of oscillation propertiesof neutral delay differential equation is reduced to that of nonneutral delay differential equa-tion, from which we give a series of oscillation theorems for neutral delay differentialequation.

  8. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Testing Analytic Systems § 493.1281 Standard: Comparison of test results. (a) If a laboratory performs the...

  9. Finding a Comparison Group: Is Online Crowdsourcing a Viable Option?

    Science.gov (United States)

    Azzam, Tarek; Jacobson, Miriam R.

    2013-01-01

    This article explores the viability of online crowdsourcing for creating matched-comparison groups. This exploratory study compares survey results from a randomized control group to survey results from a matched-comparison group created from Amazon.com's MTurk crowdsourcing service to determine their comparability. Study findings indicate…

  10. A New Comparison Principle for Impulsive Functional Differential Equations

    Directory of Open Access Journals (Sweden)

    Gang Li

    2015-01-01

    Full Text Available We establish a new comparison principle for impulsive differential systems with time delay. Then, using this comparison principle, we obtain some sufficient conditions for several stabilities of impulsive delay differential equations. Finally, we present an example to show the effectiveness of our results.

  11. Comparison of intravenous colloid and colloid‑crystalloid ...

    African Journals Online (AJOL)

    2013-09-25

    Sep 25, 2013 ... Wennberg E, Frid I, Haljamae H, Wennergren M, Kjellmer I. Comparison of Ringers acetate with 3% dextran 70 for volume loading before extradural caesarean section. Br J Anaesth 1990;65:654‑60. 11. Sharma SK, Gajraj NM, Sidawi JE. Prevention of hypotension during spinal anaesthesia. A comparison ...

  12. International comparisons of road safety using Singular Value Decomposition.

    NARCIS (Netherlands)

    Oppe, S.

    2001-01-01

    There is a general interest in the comparison of road safety developments in different countries. Comparisons have been made, based on absolute levels of accident or fatality risk or on the rate of change of functions regarding risk, the number of accidents, fatalities or injuries over time. Such

  13. Learning radiological appearances of diseases: Does comparison help?

    NARCIS (Netherlands)

    Kok, Ellen M.; de Bruin, Anique B H; Robben, Simon C. F.; van Merrienboer, Jeroen J. G.

    Comparison learning is a promising approach for learning complex real-life visual tasks. When medical students study radiological appearances of diseases, comparison of images showing diseases with images showing no abnormalities could help them learn to discriminate relevant, disease-related

  14. Gender Differences in Comparisons and Entitlement: Implications for Comparable Worth.

    Science.gov (United States)

    Major, Brenda

    1989-01-01

    Addresses the role of comparison processes in the persistence of the gender wage gap, its toleration by those disadvantaged by it, and resistance to comparable worth as a corrective strategy. Argues that gender segregation and undercompensation for women's jobs leads women to use different comparison standards when evaluating what they deserve.…

  15. International Comparisons of Income Poverty and Extreme Income Poverty

    OpenAIRE

    Blackburn, McKinley L.

    1993-01-01

    Uses LIS data to study the sensitivity of cross-national income poverty comparisons to the method in which poverty is measured. Examined are the differences between using absolute and relative poverty comparisons as well as the consequence of lowering the real value of the poverty line to examine extreme poverty.

  16. Affect and identification in social comparison after loss of work

    NARCIS (Netherlands)

    Ybema, J.F.; Buunk, Abraham (Bram); Heesink, J.A.M.

    This study examined the effects of social comparison among 172 individuals who had recently lost their jobs in a collective dismissal of employees. A part of a fictitious interview with another fired person was presented to the participants. This interview contained social comparison information on

  17. Sample sizes and model comparison metrics for species distribution models

    Science.gov (United States)

    B.B. Hanberry; H.S. He; D.C. Dey

    2012-01-01

    Species distribution models use small samples to produce continuous distribution maps. The question of how small a sample can be to produce an accurate model generally has been answered based on comparisons to maximum sample sizes of 200 observations or fewer. In addition, model comparisons often are made with the kappa statistic, which has become controversial....

  18. Comparison preferences after success or failure at school

    NARCIS (Netherlands)

    Wehrens, M. J. P. W.; Kuyper, H.; Buunk, A. P.; van der Werf, M. P. C.

    2011-01-01

    Getting an insufficient grade at school might be threatening for students. In such a situation the choice of a lower comparison level possibly functions as a self-protective strategy. The present study investigated whether students in high school reported a lower absolute preferred comparison level

  19. Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol

    International Nuclear Information System (INIS)

    Tognolini, A.; Arellano, C.S.; Marfori, W.; Heidari, G.; Sayre, J.W.; Krishnam, M.S.; Ruehm, S.G.

    2014-01-01

    Aim: To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. Materials and methods: Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37–87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. Results: The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p < 0.0001). The CNR was 18.1 ± 1.2 and 15.9 ± 1.8, respectively (p = 0.4). Four percent of SAA and 14% of CA segments (mostly due to peri-venous streak artefacts and small calibre, respectively) produced non-diagnostic images. SAA findings were as follows: 26/33 (79%) patients showed no disease and 6/33 (18%) had grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. Conclusion: A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and

  20. Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol.

    Science.gov (United States)

    Tognolini, A; Arellano, C S; Marfori, W; Heidari, G; Sayre, J W; Krishnam, M S; Ruehm, S G

    2014-03-01

    To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37-87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and coronary atherosclerotic disease. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Grip-Pattern Verification for Smart Gun Based on Maximum-Pairwise Comparison and Mean-Template Comparison

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.

    2008-01-01

    In our biometric verification system of a smart gun, the rightful user of a gun is authenticated by grip-pattern recognition. In this work verification will be done using two types of comparison methods, respectively. One is mean-template comparison, where the matching score between a test image and

  2. Comparison between uniaxially and isostatically compacted bentonite

    International Nuclear Information System (INIS)

    Kalbantner, P.; Sjoeblom, R.; Boergesson, Lennart

    2001-12-01

    The purpose of the present report is to provide the Swedish Nuclear Fuel and Waste Management Company (SKB) with the knowledge base needed for their selection of reference method for manufacturing of bentonite blocks. The purpose is also to provide support for the direction of the further development work. Three types of blocks are compared in the present report: uniaxially compacted medium high blocks, isostatically compacted medium high blocks, isostatically compacted high blocks. The analyses is based on three process systems relating to the sequence of excavation of bentonite-transport-powder preparation-compaction-handling and emplacement of bentonite blocks. The need for further knowledge has been identified and documented in conjunction with these analyses. The comparison is primarily made with regard to the criteria safety/risk, quality/ technique and economy. It is carried out through identification of issues of significance and subsequent analysis and evaluation as well as more formally in a simplified AHP (AHP = Analytical Hierarchic Process). The result of the analyses is that the isostatic technique is applicable for the production of high as well as medium size blocks. The pressed blocks are assessed to fulfil the basic requirements with a very large margin. The result of the analyses is also that the uniaxial technique is applicable for the preparation of medium size blocks, which are assessed to fulfil the basic requirements with a large margin. The need for development and process control is assessed to be somewhat higher for the uniaxial technique. One example is the friction against the walls of the die during the compaction, including the significance of this friction for the development of stresses and discontinuities in the block. These results support a selection of the isostatic technique as the reference technique as it provides flexibility in the choice of block height. The uniaxial technique can form a second alternative if medium high

  3. Comparison of Home Retrofit Programs in Wisconsin

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, Kerrie [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Hannigan, Eileen [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2013-03-01

    To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patterns of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results-program cost and energy savings-to help understand the overall strengths and weaknesses or challenges of each model.

  4. Comparison of Home Retrofit Programs in Wisconsin

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, K.; Hannigan, E.

    2013-03-01

    To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patterns of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results -- program cost and energy savings -- to help understand the overall strengths and weaknesses or challenges of each model.

  5. Protein sequence comparison and protein evolution

    Energy Technology Data Exchange (ETDEWEB)

    Pearson, W.R. [Univ. of Virginia, Charlottesville, VA (United States). Dept. of Biochemistry

    1995-12-31

    This tutorial was one of eight tutorials selected to be presented at the Third International Conference on Intelligent Systems for Molecular Biology which was held in the United Kingdom from July 16 to 19, 1995. This tutorial examines how the information conserved during the evolution of a protein molecule can be used to infer reliably homology, and thus a shared proteinfold and possibly a shared active site or function. The authors start by reviewing a geological/evolutionary time scale. Next they look at the evolution of several protein families. During the tutorial, these families will be used to demonstrate that homologous protein ancestry can be inferred with confidence. They also examine different modes of protein evolution and consider some hypotheses that have been presented to explain the very earliest events in protein evolution. The next part of the tutorial will examine the technical aspects of protein sequence comparison. Both optimal and heuristic algorithms and their associated parameters that are used to characterize protein sequence similarities are discussed. Perhaps more importantly, they survey the statistics of local similarity scores, and how these statistics can both be used to improve the selectivity of a search and to evaluate the significance of a match. They them examine distantly related members of three protein families, the serine proteases, the glutathione transferases, and the G-protein-coupled receptors (GCRs). Finally, the discuss how sequence similarity can be used to examine internal repeated or mosaic structures in proteins.

  6. Comparison of Spatiotemporal Fusion Models: A Review

    Directory of Open Access Journals (Sweden)

    Bin Chen

    2015-02-01

    Full Text Available Simultaneously capturing spatial and temporal dynamics is always a challenge for the remote sensing community. Spatiotemporal fusion has gained wide interest in various applications for its superiority in integrating both fine spatial resolution and frequent temporal coverage. Though many advances have been made in spatiotemporal fusion model development and applications in the past decade, a unified comparison among existing fusion models is still limited. In this research, we classify the models into three categories: transformation-based, reconstruction-based, and learning-based models. The objective of this study is to (i compare four fusion models (STARFM, ESTARFM, ISTAFM, and SPSTFM under a one Landsat-MODIS (L-M pair prediction mode and two L-M pair prediction mode using time-series datasets from the Coleambally irrigation area and Poyang Lake wetland; (ii quantitatively assess prediction accuracy considering spatiotemporal comparability, landscape heterogeneity, and model parameter selection; and (iii discuss the advantages and disadvantages of the three categories of spatiotemporal fusion models.

  7. Energetic and economical comparison for biomass fuel

    International Nuclear Information System (INIS)

    Galins, A.; Grundulis, A.; Zihmane, K.

    2003-01-01

    The common agricultural biomass, such as wheat straw, rape straw, wheat small corn, wheat forage, rape oil cakes and other, we can use as fuel for heat production. The biomass application for burning depends on economical situation on agriculture and fuel market. Energetic and economical parameters of agricultural biomass are estimated and compared to wooden grain. As parameters for comparison used the biomass heat value Q (MJ/kg), specific cost per 1 kWh heat production C 0 (Ls/kWh) and the fuel consumption per 1 kWh heat production M 0 (kg/kWh). The rape oil cakes have best heat value (20.82 MJ/kg), but cheapest heat energy we can get from rape straw (0.0046 Ls/kWh). Expenses of heat production for forge wheat corn (0.011 Ls/kWh) are alike to wooden chip (0.0103 Ls/kWh) and wooden grain (0.0122 Ls/kWh) (authors)

  8. A Comparison of Simulation Capabilities for Ducts

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Smith, Matt K [ORNL; Gu, Lixing [Florida Solar Energy Center (FSEC); New, Joshua Ryan [ORNL

    2014-11-01

    Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

  9. Comparison of hollow cathode discharge plasma configurations

    International Nuclear Information System (INIS)

    Farnell, Casey C; Farnell, Cody C; Williams, John D

    2011-01-01

    Hollow cathodes used in plasma contactor and electric propulsion devices provide electrons for sustaining plasma discharges and enabling plasma bridge neutralization. Life tests show erosion on hollow cathodes exposed to the plasma environment produced in the region downstream of these devices. To explain the observed erosion, plasma flow field measurements are presented for hollow cathode generated plasmas using both directly immersed probes and remotely located plasma diagnostics. Measurements on two cathode discharge configurations are presented: (1) an open, no magnetic field configuration and (2) a setup simulating the discharge chamber environment of an ion thruster. In the open cathode configuration, large amplitude plasma potential oscillations, ranging from 20 to 85 V within a 34 V discharge, were observed using a fast response emissive probe. These oscillations were observed over a dc potential profile that included a well-defined potential hill structure. A remotely located electrostatic analyzer (ESA) was used to measure the energy of ions produced within the plasma, and energies were detected that met, and in some cases exceeded, the peak oscillatory plasma potentials detected by the emissive probe. In the ion thruster discharge chamber configuration, plasma potentials from the emissive probe again agreed with ion energies recorded by the remotely located ESA; however, much lower ion energies were detected compared with the open configuration. A simplified ion-transit model that uses temporal and spatial plasma property measurements is presented and used to predict far-field plasma streaming properties. Comparisons between the model and remote measurements are presented.

  10. Comparisons of GLM and LMA Observations

    Science.gov (United States)

    Thomas, R. J.; Krehbiel, P. R.; Rison, W.; Stanley, M. A.; Attanasio, A.

    2017-12-01

    Observations from 3-dimensional VHF lightning mapping arrays (LMAs) provide a valuable basis for evaluating the spatial accuracy and detection efficiencies of observations from the recently launched, optical-based Geosynchronous Lightning Mapper (GLM). In this presentation, we describe results of comparing the LMA and GLM observations. First, the observations are compared spatially and temporally at the individual event (pixel) level for sets of individual discharges. For LMA networks in Florida, Colorado, and Oklahoma, the GLM observations are well correlated time-wise with LMA observations but are systematically offset by one- to two pixels ( 10 to 15 or 20 km) in a southwesterly direction from the actual lightning activity. The graphical comparisons show a similar location uncertainty depending on the altitude at which the scattered light is emitted from the parent cloud, due to being observed at slant ranges. Detection efficiencies (DEs) can be accurately determined graphically for intervals where individual flashes in a storm are resolved time-wise, and DEs and false alarm rates can be automated using flash sorting algorithms for overall and/or larger storms. This can be done as a function of flash size and duration, and generally shows high detection rates for larger flashes. Preliminary results during the May 1 2017 ER-2 overflight of Colorado storms indicate decreased detection efficiency if the storm is obscured by an overlying cloud layer.

  11. Method and apparatus for biological sequence comparison

    Science.gov (United States)

    Marr, T.G.; Chang, W.I.

    1997-12-23

    A method and apparatus are disclosed for comparing biological sequences from a known source of sequences, with a subject (query) sequence. The apparatus takes as input a set of target similarity levels (such as evolutionary distances in units of PAM), and finds all fragments of known sequences that are similar to the subject sequence at each target similarity level, and are long enough to be statistically significant. The invention device filters out fragments from the known sequences that are too short, or have a lower average similarity to the subject sequence than is required by each target similarity level. The subject sequence is then compared only to the remaining known sequences to find the best matches. The filtering member divides the subject sequence into overlapping blocks, each block being sufficiently large to contain a minimum-length alignment from a known sequence. For each block, the filter member compares the block with every possible short fragment in the known sequences and determines a best match for each comparison. The determined set of short fragment best matches for the block provide an upper threshold on alignment values. Regions of a certain length from the known sequences that have a mean alignment value upper threshold greater than a target unit score are concatenated to form a union. The current block is compared to the union and provides an indication of best local alignment with the subject sequence. 5 figs.

  12. Comparison of computed tomography dose reporting software

    International Nuclear Information System (INIS)

    Abdullah, A.; Sun, Z.; Pongnapang, N.; Ng, K. H.

    2008-01-01

    Computed tomography (CT) dose reporting software facilitates the estimation of doses to patients undergoing CT examinations. In this study, comparison of three software packages, i.e. CT-Expo (version 1.5, Medizinische Hochschule, Hannover (Germany)), ImPACT CT Patients Dosimetry Calculator (version 0.99x, Imaging Performance Assessment on Computed Tomography, www.impactscan.org) and WinDose (version 2.1a, Wellhofer Dosimetry, Schwarzenbruck (Germany)), has been made in terms of their calculation algorithm and the results of calculated doses. Estimations were performed for head, chest, abdominal and pelvic examinations based on the protocols recommended by European guidelines using single-slice CT (SSCT) (Siemens Somatom Plus 4, Erlangen (Germany)) and multi-slice CT (MSCT) (Siemens Sensation 16, Erlangen (Germany)) for software-based female and male phantoms. The results showed that there are some differences in final dose reporting provided by these software packages. There are deviations of effective doses produced by these software packages. Percentages of coefficient of variance range from 3.3 to 23.4 % in SSCT and from 10.6 to 43.8 % in MSCT. It is important that researchers state the name of the software that is used to estimate the various CT dose quantities. Users must also understand the equivalent terminologies between the information obtained from the CT console and the software packages in order to use the software correctly. (authors)

  13. Graphical comparison of calculated internal conversion coefficients

    International Nuclear Information System (INIS)

    Ewbank, W.B.

    1980-11-01

    Calculated values of the coefficients of internal conversion of gamma rays in the K shell and L 1 , L 2 , L 3 subshells from published tabulations by Band and Trzhaskovskaya and by Roesel et al. at Data Nucl. Data Tables, 21, 92-514(1978) are compared with values obtained by computer interpolation among tabulated values of Hager and Seltzer Nucl. Data, A4, 1-235(1968). In some cases, agreement among the three calculations is remarkably good, and differences are generally less than 5%. In a few cases, there are differences as large as 20 to 50%, corresponding to the threshold effect described by Roesel et al. The Z-dependent resonance minimum described by Roesel et al. is also observed in the comparison of E1-E4 conversion in the L 1 subshell. In several cases (notably M1-M4 conversion in the K shell and L 1 subshell), the Band and Roesel calculations show dramatically different dependence on gamma energy and atomic number. For Z = 100, the Band calculation for E4 conversion in the L 3 subshell shows irregular behavior at energies below the K-shell binding energy. A few high-quality measurements of internal conversion coefficients (+-5%) would help greatly to establish a basis for choice among the theoretical calculations. 32 figures

  14. Laparoscopic and abdominal hysterectomy: a cost comparison.

    Science.gov (United States)

    Tsaltas, J; Magnus, A; Mamers, P M; Lawrence, A S; Lolatgis, N; Healy, D L

    1997-02-17

    To compare the cost of laparoscopically assisted vaginal hysterectomy (LAVH) with that of total abdominal hysterectomy (TAH) under casemix. Retrospective comparison of the costs, operating time and length of hospital stay. The 16 women undergoing consecutive LAVH and 16 age-matched women undergoing TAH between 1 February 1994 and 31 July 1995; all women were public patients undergoing hysterectomy for benign disease. Monash Medical Centre, a large tertiary teaching hospital in Melbourne, Australia, where casemix is used to determine funding and budget allocation. The difference between the costs of the two procedures was not statistically significant (P = 0.5), despite the cost of laparoscopic hysterectomy including that of disposables. The mean operating time for TAH was 86 minutes (95% CI, 65.5-106.5), compared with 120 minutes (95% CI, 100.8-140.5) for LAVH (P < 0.01). The mean length of stay in the TAH group was 5.75 days, compared with 3.25 days in the LAVH group (P < 0.001). In hysterectomy for benign gynaecological disease, the laparoscopic procedure costs the same as the total abdominal procedure. Audit such as this is important in patient management and in guiding hospitals in funding and bed allocation.

  15. Safeguards inventory and process monitoring regulatory comparison

    Energy Technology Data Exchange (ETDEWEB)

    Cavaluzzi, Jack M. [Texas A & M Univ., College Station, TX (United States); Gibbs, Philip W. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2013-06-27

    Detecting the theft or diversion of the relatively small amount of fissile material needed to make a nuclear weapon given the normal operating capacity of many of today’s running nuclear production facilities is a difficult task. As throughput increases, the ability of the Material Control and Accountability (MC&A) Program to detect the material loss decreases because the statistical measurement uncertainty also increases. The challenge faced is the ability of current accounting, measurement, and material control programs to detect small yet significant losses under some regulatory approaches can decrease to the point where it is extremely low if not practically non-existent at normal operating capacities. Adding concern to this topic is that there are variations among regulatory bodies as far as what is considered a Significant Quantity (SQ). Some research suggests that thresholds should be lower than those found in any current regulation which if adopted would make meeting detection goals even more difficult. This paper reviews and compares the current regulatory requirements for the MA elements related to physical inventory, uncertainty of the Inventory Difference (ID), and Process Monitoring (PM) in the United States Department of Energy (DOE) and Nuclear Regulatory Commission (NRC), Rosatom of the Russian Federation and the Chinese Atomic Energy Agency (CAEA) of China. The comparison looks at how the regulatory requirements for the implementation of various MA elements perform across a range of operating capacities in example facilities.

  16. Aerosol Angstrom Absorption Coefficient Comparisons during MILAGRO.

    Science.gov (United States)

    Marley, N. A.; Marchany-Rivera, A.; Kelley, K. L.; Mangu, A.; Gaffney, J. S.

    2007-12-01

    Measurements of aerosol absorption were obtained as part of the MAX-Mex component of the MILAGRO field campaign at site T0 (Instituto Mexicano de Petroleo in Mexico City) by using a 7-channel aethalometer (Thermo- Anderson) during the month of March, 2006. The absorption measurements obtained in the field at 370, 470, 520, 590, 660, 880, and 950 nm were used to determine the aerosol Angstrom absorption exponents by linear regression. Since, unlike other absorbing aerosol species (e.g. humic like substances, nitrated PAHs), black carbon absorption is relatively constant from the ultraviolet to the infrared with an Angstrom absorption exponent of -1 (1), a comparison of the Angstrom exponents can indicate the presence of aerosol components with an enhanced UV absorption over that expected from BC content alone. The Angstrom exponents determined from the aerosol absorption measurements obtained in the field varied from - 0.7 to - 1.3 during the study and was generally lower in the afternoon than the morning hours, indicating an increase in secondary aerosol formation and photochemically generated UV absorbing species in the afternoon. Twelve-hour integrated samples of fine atmospheric aerosols (Petroleo (IMP) and CENICA.

  17. Comparison of post circumcision complications and wound

    International Nuclear Information System (INIS)

    Malik, S.; Ahmad, S.A.; Habib, A.

    2015-01-01

    The objective of this study is to compare the frequency of post circumcision complications like bleeding and infection along with wound healing in infants by conventional open method and the bone-cutter method. Study Design: Randomized controlled trial. Place and Duration of Study: Combined Military Hospital and Military Hospital Rawalpindi, from March 2009 to March 2010. Patients and Methods: A total of 400 patients were included in the study that underwent circumcision. Patients were randomly allotted to either group A in whom the circumcision was done with conventional open technique (n = 200) or to group B, in whom circumcision was done with bone-cutter (n = 200). Patients were followed up in the surgical OPD after 5 days for assessment and earlier in case of any complication. Outcomes were measured by absence or presence of infection, post operative bleeding and cosmetic acceptance by the parents. Results: Comparison between the two groups showed that the bleeding rate was 8% in group A and 7% in group B (p = 0.704). Infection rate was 6% in group A and 5% in group B (p = 0.661). Delayed wound healing was seen in 4% of circumcisions in group A as opposed to 2% in group B ( p = 0.241). Conclusion: Complication is a part of any surgical procedure. So is the case with circumcision however no significant difference was found between the two procedures in terms of bleeding, infection, trauma to the glans and the cosmetic outcome. (author)

  18. Comparison of Sequential and Variational Data Assimilation

    Science.gov (United States)

    Alvarado Montero, Rodolfo; Schwanenberg, Dirk; Weerts, Albrecht

    2017-04-01

    Data assimilation is a valuable tool to improve model state estimates by combining measured observations with model simulations. It has recently gained significant attention due to its potential in using remote sensing products to improve operational hydrological forecasts and for reanalysis purposes. This has been supported by the application of sequential techniques such as the Ensemble Kalman Filter which require no additional features within the modeling process, i.e. it can use arbitrary black-box models. Alternatively, variational techniques rely on optimization algorithms to minimize a pre-defined objective function. This function describes the trade-off between the amount of noise introduced into the system and the mismatch between simulated and observed variables. While sequential techniques have been commonly applied to hydrological processes, variational techniques are seldom used. In our believe, this is mainly attributed to the required computation of first order sensitivities by algorithmic differentiation techniques and related model enhancements, but also to lack of comparison between both techniques. We contribute to filling this gap and present the results from the assimilation of streamflow data in two basins located in Germany and Canada. The assimilation introduces noise to precipitation and temperature to produce better initial estimates of an HBV model. The results are computed for a hindcast period and assessed using lead time performance metrics. The study concludes with a discussion of the main features of each technique and their advantages/disadvantages in hydrological applications.

  19. Comparison of validation methods for forming simulations

    Science.gov (United States)

    Schug, Alexander; Kapphan, Gabriel; Bardl, Georg; Hinterhölzl, Roland; Drechsler, Klaus

    2018-05-01

    The forming simulation of fibre reinforced thermoplastics could reduce the development time and improve the forming results. But to take advantage of the full potential of the simulations it has to be ensured that the predictions for material behaviour are correct. For that reason, a thorough validation of the material model has to be conducted after characterising the material. Relevant aspects for the validation of the simulation are for example the outer contour, the occurrence of defects and the fibre paths. To measure these features various methods are available. Most relevant and also most difficult to measure are the emerging fibre orientations. For that reason, the focus of this study was on measuring this feature. The aim was to give an overview of the properties of different measuring systems and select the most promising systems for a comparison survey. Selected were an optical, an eddy current and a computer-assisted tomography system with the focus on measuring the fibre orientations. Different formed 3D parts made of unidirectional glass fibre and carbon fibre reinforced thermoplastics were measured. Advantages and disadvantages of the tested systems were revealed. Optical measurement systems are easy to use, but are limited to the surface plies. With an eddy current system also lower plies can be measured, but it is only suitable for carbon fibres. Using a computer-assisted tomography system all plies can be measured, but the system is limited to small parts and challenging to evaluate.

  20. Comparison of infusion pumps calibration methods

    Science.gov (United States)

    Batista, Elsa; Godinho, Isabel; do Céu Ferreira, Maria; Furtado, Andreia; Lucas, Peter; Silva, Claudia

    2017-12-01

    Nowadays, several types of infusion pump are commonly used for drug delivery, such as syringe pumps and peristaltic pumps. These instruments present different measuring features and capacities according to their use and therapeutic application. In order to ensure the metrological traceability of these flow and volume measuring equipment, it is necessary to use suitable calibration methods and standards. Two different calibration methods can be used to determine the flow error of infusion pumps. One is the gravimetric method, considered as a primary method, commonly used by National Metrology Institutes. The other calibration method, a secondary method, relies on an infusion device analyser (IDA) and is typically used by hospital maintenance offices. The suitability of the IDA calibration method was assessed by testing several infusion instruments at different flow rates using the gravimetric method. In addition, a measurement comparison between Portuguese Accredited Laboratories and hospital maintenance offices was performed under the coordination of the Portuguese Institute for Quality, the National Metrology Institute. The obtained results were directly related to the used calibration method and are presented in this paper. This work has been developed in the framework of the EURAMET projects EMRP MeDD and EMPIR 15SIP03.

  1. Experimental comparison of two quantum computing architectures.

    Science.gov (United States)

    Linke, Norbert M; Maslov, Dmitri; Roetteler, Martin; Debnath, Shantanu; Figgatt, Caroline; Landsman, Kevin A; Wright, Kenneth; Monroe, Christopher

    2017-03-28

    We run a selection of algorithms on two state-of-the-art 5-qubit quantum computers that are based on different technology platforms. One is a publicly accessible superconducting transmon device (www. ibm.com/ibm-q) with limited connectivity, and the other is a fully connected trapped-ion system. Even though the two systems have different native quantum interactions, both can be programed in a way that is blind to the underlying hardware, thus allowing a comparison of identical quantum algorithms between different physical systems. We show that quantum algorithms and circuits that use more connectivity clearly benefit from a better-connected system of qubits. Although the quantum systems here are not yet large enough to eclipse classical computers, this experiment exposes critical factors of scaling quantum computers, such as qubit connectivity and gate expressivity. In addition, the results suggest that codesigning particular quantum applications with the hardware itself will be paramount in successfully using quantum computers in the future.

  2. A Comparison of Power Quality Controllers

    Directory of Open Access Journals (Sweden)

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  3. Distributed Wind Policy Comparison Tool Guidebook

    Energy Technology Data Exchange (ETDEWEB)

    2011-11-01

    Power through Policy: 'Best Practices' for Cost-Effective Distributed Wind is a U.S. Department of Energy (DOE)-funded project to identify distributed wind technology policy best practices and to help policymakers, utilities, advocates, and consumers examine their effectiveness using a pro forma model. Incorporating a customized feed from the Database of State Incentives for Renewables and Efficiency (DSIRE), the Web-based Distributed Wind Policy Comparison Tool (Policy Tool) is designed to assist state, local, and utility officials in understanding the financial impacts of different policy options to help reduce the cost of distributed wind technologies. The Policy Tool can be used to evaluate the ways that a variety of federal and state policies and incentives impact the economics of distributed wind (and subsequently its expected market growth). It also allows policymakers to determine the impact of policy options, addressing market challenges identified in the U.S. DOE's '20% Wind Energy by 2030' report and helping to meet COE targets.

  4. Comparison between electroglottography and electromagnetic glottography

    Energy Technology Data Exchange (ETDEWEB)

    Titze, Ingo R. [Department of Speech Pathology and Audiology and National Center for Voice and Speech, The University of Iowa and the Denver Center for the Performing Arts, Iowa City, Iowa 52242 (United States); Story, Brad H. [Department of Speech Pathology and Audiology and National Center for Voice and Speech, The University of Iowa and the Denver Center for the Performing Arts, Iowa City, Iowa 52242 (United States); Burnett, Gregory C. [Department of Applied Science, University of California at Davis, and Lawrence Livermore National Laboratory, Livermore, California 94557 (United States); Holzrichter, John F. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Ng, Lawrence C. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Lea, Wayne A. [Speech Sciences Institute, Apple Valley, Minnesota 55124 (United States)

    2000-01-01

    Newly developed glottographic sensors, utilizing high-frequency propagating electromagnetic waves, were compared to a well-established electroglottographic device. The comparison was made on four male subjects under different phonation conditions, including three levels of vocal fold adduction (normal, breathy, and pressed), three different registers (falsetto, chest, and fry), and two different pitches. Agreement between the sensors was always found for the glottal closure event, but for the general wave shape the agreement was better for falsetto and breathy voice than for pressed voice and vocal fry. Differences are attributed to the field patterns of the devices. Whereas the electroglottographic device can operate only in a conduction mode, the electromagnetic device can operate in either the forward scattering (diffraction) mode or in the backward scattering (reflection) mode. Results of our tests favor the diffraction mode because a more favorable angle imposed on receiving the scattered (reflected) signal did not improve the signal strength. Several observations are made on the uses of the electromagnetic sensors for operation without skin contact and possibly in an array configuration for improved spatial resolution within the glottis. (c) 2000 Acoustical Society of America.

  5. A Comprehensive Comparison of Relativistic Particle Integrators

    Science.gov (United States)

    Ripperda, B.; Bacchini, F.; Teunissen, J.; Xia, C.; Porth, O.; Sironi, L.; Lapenta, G.; Keppens, R.

    2018-03-01

    We compare relativistic particle integrators commonly used in plasma physics, showing several test cases relevant for astrophysics. Three explicit particle pushers are considered, namely, the Boris, Vay, and Higuera–Cary schemes. We also present a new relativistic fully implicit particle integrator that is energy conserving. Furthermore, a method based on the relativistic guiding center approximation is included. The algorithms are described such that they can be readily implemented in magnetohydrodynamics codes or Particle-in-Cell codes. Our comparison focuses on the strengths and key features of the particle integrators. We test the conservation of invariants of motion and the accuracy of particle drift dynamics in highly relativistic, mildly relativistic, and non-relativistic settings. The methods are compared in idealized test cases, i.e., without considering feedback onto the electrodynamic fields, collisions, pair creation, or radiation. The test cases include uniform electric and magnetic fields, {\\boldsymbol{E}}× {\\boldsymbol{B}} fields, force-free fields, and setups relevant for high-energy astrophysics, e.g., a magnetic mirror, a magnetic dipole, and a magnetic null. These tests have direct relevance for particle acceleration in shocks and in magnetic reconnection.

  6. A comparison of interface tracking methods

    International Nuclear Information System (INIS)

    Kothe, D.B.; Rider, W.J.

    1995-01-01

    In this Paper we provide a direct comparison of several important algorithms designed to track fluid interfaces. In the process we propose improved criteria by which these methods are to be judged. We compare and contrast the behavior of the following interface tracking methods: high order monotone capturing schemes, level set methods, volume-of-fluid (VOF) methods, and particle-based (particle-in-cell, or PIC) methods. We compare these methods by first applying a set of standard test problems, then by applying a new set of enhanced problems designed to expose the limitations and weaknesses of each method. We find that the properties of these methods are not adequately assessed until they axe tested with flows having spatial and temporal vorticity gradients. Our results indicate that the particle-based methods are easily the most accurate of those tested. Their practical use, however, is often hampered by their memory and CPU requirements. Particle-based methods employing particles only along interfaces also have difficulty dealing with gross topology changes. Full PIC methods, on the other hand, do not in general have topology restrictions. Following the particle-based methods are VOF volume tracking methods, which are reasonably accurate, physically based, robust, low in cost, and relatively easy to implement. Recent enhancements to the VOF methods using multidimensional interface reconstruction and improved advection provide excellent results on a wide range of test problems

  7. A questionnaire comparison of two alarm systems

    International Nuclear Information System (INIS)

    Collier, Steven G.

    1997-11-01

    A questionnaire was developed, based on guidelines for alarm system design given in NUREG/CR-6105. The intentions were both to develop a subjective instrument for rating the effectiveness of alarm systems and to learn lessons on alarm system design from a comparison of two systems. The questionnaire was administered to reactor operations staff at two locations with different alarm systems embedded in a simulation of the same underlying PWR power plant: Loviisa NPP and Halden Man-Machine Laboratory. The questionnaire, considered as a measuring instrument, had good to high reliability and moderate to good content validity. The questionnaire is considered suitable for further use in the shortened form resulting from this study. Further work is also recommended. The degree of reliability and validity also lend a degree of validation to the NUREG guidelines. The questionnaire was able to show differences between ratings of the two alarm systems. The Loviisa system showed more consistency with other control room features and was better at drawing the operators' attention to important alarms. Both systems were not rated particularly well on alarm prioritisation and spurious alarms. The Halden system was better at showing naturally occurring relationships between alarms. Some of these differences may have been due to the subjects' greater familiarity with the Loviisa alarm system. The results nevertheless show that the questionnaire can measure subjective responses to alarm systems. (author)

  8. Comparison between electroglottography and electromagnetic glottography

    International Nuclear Information System (INIS)

    Titze, Ingo R.; Story, Brad H.; Burnett, Gregory C.; Holzrichter, John F.; Ng, Lawrence C.; Lea, Wayne A.

    2000-01-01

    Newly developed glottographic sensors, utilizing high-frequency propagating electromagnetic waves, were compared to a well-established electroglottographic device. The comparison was made on four male subjects under different phonation conditions, including three levels of vocal fold adduction (normal, breathy, and pressed), three different registers (falsetto, chest, and fry), and two different pitches. Agreement between the sensors was always found for the glottal closure event, but for the general wave shape the agreement was better for falsetto and breathy voice than for pressed voice and vocal fry. Differences are attributed to the field patterns of the devices. Whereas the electroglottographic device can operate only in a conduction mode, the electromagnetic device can operate in either the forward scattering (diffraction) mode or in the backward scattering (reflection) mode. Results of our tests favor the diffraction mode because a more favorable angle imposed on receiving the scattered (reflected) signal did not improve the signal strength. Several observations are made on the uses of the electromagnetic sensors for operation without skin contact and possibly in an array configuration for improved spatial resolution within the glottis. (c) 2000 Acoustical Society of America

  9. Species comparison of inflammatory cell reactivity

    Energy Technology Data Exchange (ETDEWEB)

    Boncavage-Hennessey, E.M.; Twerdok, L.E. [Geo-Centers, Inc., Frederick, MD (United States); Finch, R.A.; Gardner, H.S. [Army Biomedical Research and Development Lab., Frederick, MD (United States)

    1994-12-31

    In comparison to the use of rodent models, the use of fish as a potential model to predict immune dysfunction in response to environmental contaminants is a relatively new concept. The development of a fish model for immunotoxicity is possible due to the phylogenetic conservation of many immune functions. The authors have compared mononuclear cell reactivity following in vitro stimulation among five species; Japanese medaka (Oryzias latipes), rainbow trout (Oncorhynchus mykiss), DBA/2 mice, Sprague-Dawley rats and human ML-1 cells. Mononuclear cells were isolated from the rodent bone marrow and from the teleost anterior kidney (the cell population which most closely resembles mammalian hematopoietic tissue). ML-1 cells are a myeloblastic cell line that were differentiated in vitro to monocytes/macrophages. Cell populations were characterized by myeloperoxidase and nonspecific esterase staining characteristic. Reactive oxidant production following in vitro stimulation by phorbol ester was measured using the following methods: reduction of cytochrome c (detection of extracellular superoxide), reduction of nitroblue tetrazolium (detection of intracellular superoxide) and oxidation of phenol red in the presence of horseradish peroxidase (hydrogen peroxide production). In general, teleost cells demonstrated higher superoxide anion production and mammalian cells produced higher quantities of hydrogen peroxide.

  10. Perceptual expertise in forensic facial image comparison.

    Science.gov (United States)

    White, David; Phillips, P Jonathon; Hahn, Carina A; Hill, Matthew; O'Toole, Alice J

    2015-09-07

    Forensic facial identification examiners are required to match the identity of faces in images that vary substantially, owing to changes in viewing conditions and in a person's appearance. These identifications affect the course and outcome of criminal investigations and convictions. Despite calls for research on sources of human error in forensic examination, existing scientific knowledge of face matching accuracy is based, almost exclusively, on people without formal training. Here, we administered three challenging face matching tests to a group of forensic examiners with many years' experience of comparing face images for law enforcement and government agencies. Examiners outperformed untrained participants and computer algorithms, thereby providing the first evidence that these examiners are experts at this task. Notably, computationally fusing responses of multiple experts produced near-perfect performance. Results also revealed qualitative differences between expert and non-expert performance. First, examiners' superiority was greatest at longer exposure durations, suggestive of more entailed comparison in forensic examiners. Second, experts were less impaired by image inversion than non-expert students, contrasting with face memory studies that show larger face inversion effects in high performers. We conclude that expertise in matching identity across unfamiliar face images is supported by processes that differ qualitatively from those supporting memory for individual faces. © 2015 The Author(s).

  11. Comparison of Ontology Reasoners: Racer, Pellet, Fact++

    Science.gov (United States)

    Huang, T.; Li, W.; Yang, C.

    2008-12-01

    In this paper, we examine some key aspects of three of the most popular and effective Semantic reasoning engines that have been developed: Pellet, RACER, and Fact++. While these reasonably advanced reasoners share some notable similarities, it is ultimately the creativity and unique nature of these reasoning engines that have resulted in the successes of each of these reasoners. Of the numerous dissimilarities, the most obvious example might be that while Pellet is written in Java, RACER employs the Lisp programming language and Fact++ was developed using C++. From this and many other distinctions in the system architecture, we can understand the benefits of each reasoner and potentially discover certain properties that may contribute to development of an optimal reasoner in the future. The objective of this paper is to establish a solid comparison of the reasoning engines based on their system architectures, features, and overall performances in real world application. In the end, we expect to produce a valid conclusion about the advantages and problems in each reasoner. While there may not be a decisive first place among the three reasoners, the evaluation will also provide some answers as to which of these current reasoning tools will be most effective in common, practical situations.

  12. Pictorial review: Electron beam computed tomography and multislice spiral computed tomography for cardiac imaging

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Dohmen, Pascal M.; Klessen, Christian; Wiese, Till H.; Hoffmann, Udo; Hamm, Bernd; Enzweiler, Christian N.H.

    2006-01-01

    Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure

  13. Investigations into the methodology of intramyocardial scintiscanning and its uses in the diagnosis and differential diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Bauer, R.

    1983-01-01

    Some 3000 patients were subjected to radionuclide ventriculography (RNV) in order to assess their cardiac functions. The individual steps involved in the procedure were in vivo/in vitro 99m-Tc labelling of erythrocyte DPNA using a method developed by myself, an ECG-triggered system, further an uptake programme permitting reconstruction of the cardiac rhythm that was also developed by myself, and eventually an evaluation programme ensuring a detailed and reproducible analysis of the overall and regional cardiac function. In order to compare and validate the results thus obtained, additional examinations were carried out using 99m-Tc HSA as a tracer substance as well as contrast-enhanced angiography both at rest and during exercise. In comparison with other non-invasive methods - ECG recordings during exercise and myocardial scintiscanning using TL-201-RNV was found to be the most sensitive ans presumably also the most specific technique to diagnose coronary heart disease (CHD). If its high diagnostic accuracy is, however, balanced against the costs involved, it becomes obvious that it cannot be recommended as a large-scale screening method. RNV certainly is indicated in selected groups of patients showing a prevalence of intermediary clinical symptoms, to monitor the cardiac function in various diseases of the heart and to assess the effectiveness of drug and surgical treatments, provided that the relative risks, costs and diagnostic value of the data obtained are weighed up carefully. (TRV) [de

  14. Visualisation of regional motility disorders in the left ventricular wall using radionuclide ventriculography

    International Nuclear Information System (INIS)

    Kaiser, H.

    1985-01-01

    During this study ECG-triggered intramyocardial scintiscans were obtained following in-vivo labelling of erythrocytes (99mTc) from 74 patients showing coronary heart disease and analysed with the aim to assess the suitability of this method for the detection of mural motility disorders and for visualisation of the accurate size of the left ventricle. The results of the intramyocardial scintiscans were evaluated against those of levocardiograms recorded for reasons of comparison and found to demonstrate mural motility disorders with a specifity of 0.70 and a sensitivity of 0.75. Relatively reliable data to diagnose those myocardial motility disorders were obtained by combined analysis of the individual scintiphotographic displays of amplitudes, phases, ejection fractions and positive gradients. The investigation of further parameters like the recorded stroke volumes and negative gradients provided no additional information. The phase recording proved to be the most suitable parameter to assess the size of the left ventricle. All other recordings gave a distorted picture of the left ventricle in terms of a reduction in size. (TRV) [de

  15. Cardiac effects of granisetron in a prospective crossover randomized dose comparison trial.

    Science.gov (United States)

    Cakir, F B; Yapar, O; Canpolat, C; Akalin, F; Berrak, S G

    2012-10-01

    Cardiac side effects of granisetron have been studied mostly in adult patients that are using cardiotoxic chemotherapeutics. There is limited evidence in pediatric age group and no information in pediatric oncology patients with non-cardiotoxic chemotherapeutics. In this prospective, crossover randomized study, the cardiac side effects of granisetron are compared in pediatric oncology patients who had carboplatin based chemotherapy. They were randomized to receive either 10 or 40 μg kg(-1) dose(-1) of granisetron before each cycle of chemotherapy. We drew blood for creatine phosphokinase (CPK), CPK-muscle band (MB) and Troponin-T before and 24 h after administering granisetron. Electrocardiography (ECG) tracings were taken at 0, 1, 2, 3, 6 and 24 h of granisetron. Twenty-four hours Holter ECG monitorisation was performed after each granisetron infusion. A total of 16 patients (median 8.7 years of age) were treated with weekly consecutive courses of carboplatin. There was bradycardia (p = 0.000) in patients that had granisetron at 40 μg/kg and PR interval was shortened in patients that had granisetron at 10 μg/kg dose (p = 0.021). At both doses of granisetron, QTc interval and dispersion were found to be similar. CPK, CK-MB and Troponin-T values were found to be normal before and 24 h after granisetron infusion. As the first study that has studied cardiac side effects of granisetron in patients that are not using cardiotoxic chemotherapeutics, we conclude that granisetron at 40 μg kg(-1) dose(-1) causes bradycardia only. We have also demonstrated that granisetron does not cause any clinically cardiac side effects either at 10 or 40 μg kg(-1) dose(-1). However, our results should be supported by prospective randomized studies with larger samples of patient groups.

  16. Myocardial Protection in Mitral Valve Surgery: Comparison Between Minimally Invasive Approach and Standard Sternotomy.

    Science.gov (United States)

    Lebon, Jean-Sébastien; Couture, Pierre; Fortier, Annik; Rochon, Antoine G; Ayoub, Christian; Viens, Claudia; Laliberté, Éric; Bouchard, Denis; Pellerin, Michel; Deschamps, Alain

    2018-04-01

    To compare antegrade and retrograde cardioplegia administration in minimally invasive mitral valve surgery (MIMS) and open mitral valve surgery (OMS) for myocardial protection. Retrospective study. Tertiary care university hospital. The study comprised 118 patients undergoing MIMS and 118 patients undergoing OMS. The data of patients admitted for MIMS from 2006 to 2010 were reviewed. Patients undergoing isolated elective OMS from 2004 to 2006 were used as a control group. Cardioplegia in the MIMS group was delivered via the distal port of the endoaortic clamp and an endovascular coronary sinus catheter positioned using echographic and fluoroscopic guidance. Antegrade and retrograde cardioplegia were used in OMS. Data regarding myocardial infarction (MI) (creatine kinase [CK]-MB, troponin T, electrocardiography); myocardial function; and hemodynamic stability were collected. There was no difference in the perioperative MI incidence between both groups (1 in each group, p = 0.96). No statistically significant difference was found for maximal CK-MB (35.9 µg/L [25.1-50.1] v 37.9 µg/L [28.6-50.9]; p = 0.31) or the number of patients with CK-MB levels >50 µg/L (29 v 33; p = 0.55) or CK-MB >100 µg/L (3 v 4; p = 0.70) between the OMS and MIMS groups. However, maximum troponin T levels in the MIMS group were significantly lower (0.47 µg/L [0.32-0.79] v 0.65 µg/L [0.45-0.94]; p = 0.0007). No difference in the incidence of difficult weaning from bypass and intra-aortic balloon pump use between the MIMS and OMS groups was found. Antegrade and retrograde cardioplegia administration during MIMS and OMS provided comparable myocardial protection. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  17. Comparison of high-latitude thermospheric meridionalwinds I: optical and radar experimental comparisons

    Directory of Open Access Journals (Sweden)

    E. M. Griffin

    2004-03-01

    Full Text Available Thermospheric neutral winds at Kiruna, Sweden (67.4°N, 20.4°E are compared using both direct optical Fabry-Perot Interferometer (FPI measurements and those derived from European incoherent scatter radar (EISCAT measurements. This combination of experimental data sets, both covering well over a solar cycle of data, allows for a unique comparison of the thermospheric meridional component of the neutral wind as observed by different experimental techniques. Uniquely in this study the EISCAT measurements are used to provide winds for comparison using two separate techniques: the most popular method based on the work of Salah and Holt (1974 and the Meridional Wind Model (MWM (Miller et al., 1997 application of servo theory. The balance of forces at this location that produces the observed diurnal pattern are investigated using output from the Coupled Thermosphere and Ionosphere (CTIM numerical model. Along with detailed comparisons from short periods the climatological behaviour of the winds have been investigated for seasonal and solar cycle dependence using the experimental techniques. While there are features which are consistent between the 3 techniques, such as the evidence of the equinoctial asymmetry, there are also significant differences between the techniques both in terms of trends and absolute values. It is clear from this and previous studies that the high-latitude representation of the thermospheric neutral winds from the empirical Horizontal Wind Model (HWM, though improved from earlier versions, lacks accuracy in many conditions. The relative merits of each technique are discussed and while none of the techniques provides the perfect data set to address model performance at high-latitude, one or more needs to be included in future HWM reformulations.

    Key words. Meteorology and atmospheric dynamics (thermospheric dynamics, Ionosphere (ionosphere-atmosphere interactions, auroral ionosphere

  18. Comparison of high-latitude thermospheric meridionalwinds I: optical and radar experimental comparisons

    Directory of Open Access Journals (Sweden)

    E. M. Griffin

    2004-03-01

    Full Text Available Thermospheric neutral winds at Kiruna, Sweden (67.4°N, 20.4°E are compared using both direct optical Fabry-Perot Interferometer (FPI measurements and those derived from European incoherent scatter radar (EISCAT measurements. This combination of experimental data sets, both covering well over a solar cycle of data, allows for a unique comparison of the thermospheric meridional component of the neutral wind as observed by different experimental techniques. Uniquely in this study the EISCAT measurements are used to provide winds for comparison using two separate techniques: the most popular method based on the work of Salah and Holt (1974 and the Meridional Wind Model (MWM (Miller et al., 1997 application of servo theory. The balance of forces at this location that produces the observed diurnal pattern are investigated using output from the Coupled Thermosphere and Ionosphere (CTIM numerical model. Along with detailed comparisons from short periods the climatological behaviour of the winds have been investigated for seasonal and solar cycle dependence using the experimental techniques. While there are features which are consistent between the 3 techniques, such as the evidence of the equinoctial asymmetry, there are also significant differences between the techniques both in terms of trends and absolute values. It is clear from this and previous studies that the high-latitude representation of the thermospheric neutral winds from the empirical Horizontal Wind Model (HWM, though improved from earlier versions, lacks accuracy in many conditions. The relative merits of each technique are discussed and while none of the techniques provides the perfect data set to address model performance at high-latitude, one or more needs to be included in future HWM reformulations. Key words. Meteorology and atmospheric dynamics (thermospheric dynamics, Ionosphere (ionosphere-atmosphere interactions, auroral ionosphere

  19. Comparison of high-latitude thermospheric meridional winds I: optical and radar experimental comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, E.M.; Mueller-Wodarg, I.C.F.; Aruliah, A.; Aylward, A. [Atmospheric Physics Lab., Univ. Coll. London, London (United Kingdom)

    2004-07-01

    Thermospheric neutral winds at Kiruna, Sweden (67.4 N, 20.4 E) are compared using both direct optical fabry-perot interferometer (FPI) measurements and those derived from European incoherent scatter radar (EISCAT) measurements. This combination of experimental data sets, both covering well over a solar cycle of data, allows for a unique comparison of the thermospheric meridional component of the neutral wind as observed by different experimental techniques. Uniquely in this study the EISCAT measurements are used to provide winds for comparison using two separate techniques: the most popular method based on the work of Salah and Holt (1974) and the meridional wind model (MWM) (Miller et al., 1997) application of servo theory. The balance of forces at this location that produces the observed diurnal pattern are investigated using output from the coupled thermosphere and ionosphere (CTIM) numerical model. Along with detailed comparisons from short periods the climatological behaviour of the winds have been investigated for seasonal and solar cycle dependence using the experimental techniques. While there are features which are consistent between the 3 techniques, such as the evidence of the equinoctial asymmetry, there are also significant differences between the techniques both in terms of trends and absolute values. It is clear from this and previous studies that the high-latitude representation of the thermospheric neutral winds from the empirical horizontal wind model (HWM), though improved from earlier versions, lacks accuracy in many conditions. The relative merits of each technique are discussed and while none of the techniques provides the perfect data set to address model performance at high-latitude, one or more needs to be included in future HWM reformulations. (orig.)

  20. Comparison of Standard and Fast Charging Methods for Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Petr Chlebis

    2014-01-01

    Full Text Available This paper describes a comparison of standard and fast charging methods used in the field of electric vehicles and also comparison of their efficiency in terms of electrical energy consumption. The comparison was performed on three-phase buck converter, which was designed for EV’s fast charging station. The results were obtained by both mathematical and simulation methods. The laboratory model of entire physical application, which will be further used for simulation results verification, is being built in these days.

  1. Quality control of radionuclide calibrators: Interlaboratory comparison of thallium-201

    International Nuclear Information System (INIS)

    Debertin, K.

    1985-01-01

    After 131 I and sup(99m)Tc comparisons in 1982 and 1983, the Physikalisch-Technische Bundesanstalt (PTB) in cooperation with the firm Amersham-Buchler organized a further comparison in October 1984 in order to investigate the accuracy of activity measurements in nuclear medicine. 48 hospitals or institutes participated in this 201 TI comparison. The wast majority of the reported results agreed with the PTB-value to within 10%, however in 5 cases deviations amounted to more than 20%. (orig.) [de

  2. International price comparisons for pharmaceuticals. Measurement and policy issues.

    Science.gov (United States)

    Danzon, P M; Kim, J D

    1998-01-01

    Cross-national price comparisons for pharmaceuticals are commonly used for two purposes. Comparisons based on a sample of products are used to draw conclusions about differences in average price levels. Cross-national comparisons applied to individual products are also used by governments to set domestic prices. This paper examines the major methodological issues raised by international price comparisons, focusing on measurement of differences in average price levels and the validity of policy conclusions drawn from such price comparison studies. It argues that valid measures of average price levels can only be obtained from comparisons based on a comprehensive or representative sample of products, appropriately weighted, following standard index number methods. Comparisons of individual product prices should take into account the manufacturer's entire product portfolio over time rather than focus narrowly on a single product at a point in time. Because of the great variation across countries in both the range of drug compounds available and the dosage forms, strengths and pack sizes for each compound, obtaining a broadly comprehensive or representative sample is problematical. If products are required to match on all dimensions, including molecule, manufacturer, strength and pack, as is common in most international price comparisons, then only a very small and unrepresentative sample of the drugs available in each country can be included in the analysis. A trade-off between the desire to compare only identical products and the need to compare a truly representative sample of a country's pharmaceutical market is therefore necessary. A valid comparison of average drug prices should include generics and over-the-counter products that are good substitutes for branded prescription drugs, with all forms, strengths and packs. To achieve this broad representation, however, the requirements of same manufacturer, same brand, dosage form, strength and pack size must be

  3. KEY COMPARISON: Key comparison CCQM-K60: Total selenium and selenomethionine in selenised wheat flour

    Science.gov (United States)

    Goenaga Infante, Heidi; Sargent, Mike

    2010-01-01

    Key comparison CCQM-K60 was performed to assess the analytical capabilities of national metrology institutes (NMIs) to accurately quantitate the mass fraction of selenomethionine (SeMet) and total selenium (at low mg kg-1 levels) in selenised wheat flour. It was organized by the Inorganic Analysis Working Group (IAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) as a follow-up key comparison to the previous pilot study CCQM-P86 on selenised yeast tablets. LGC Limited (Teddington, UK) and the Institute for National Measurement Standards, National Research Council Canada (NRCC, Ottawa, Canada) acted as the coordinating laboratories. CCQM-K60 was organized in parallel with a pilot study (CCQM-P86.1) involving not only NMIs but also expert laboratories worldwide, thus enabling them to assess their capabilities, discover problems and learn how to modify analytical procedures accordingly. Nine results for total Se and four results for SeMet were reported by the participant NMIs. Methods used for sample preparation were microwave assisted acid digestion for total Se and multiple-step enzymatic hydrolysis and hydrolysis with methanesulfonic acid for SeMet. For total Se, detection techniques included inductively coupled plasma mass spectrometry (ICP-MS) with external calibration, standard additions or isotope dilution analysis (IDMS); instrumental neutron activation analysis (INAA); and graphite furnace atomic absorption spectrometry (GFAAS) with external calibration. For determination of SeMet in the wheat flour sample, the four NMIs relied upon measurements using species-specific IDMS (using 76Se-enriched SeMet) with HPLC-ICP-MS. Eight of the nine participating NMIs reported results for total Se within 3.5% deviation from the key comparison reference value (KCRV). For SeMet, the four participating NMIs reported results within 3.2% deviation from the KCRV. This shows that the performance of the majority of the CCQM-K60 participants was very good

  4. COMPARISON OF METHODS FOR GEOMETRIC CAMERA CALIBRATION

    Directory of Open Access Journals (Sweden)

    J. Hieronymus

    2012-09-01

    Full Text Available Methods for geometric calibration of cameras in close-range photogrammetry are established and well investigated. The most common one is based on test-fields with well-known pattern, which are observed from different directions. The parameters of a distortion model are calculated using bundle-block-adjustment-algorithms. This methods works well for short focal lengths, but is essentially more problematic to use with large focal lengths. Those would require very large test-fields and surrounding space. To overcome this problem, there is another common method for calibration used in remote sensing. It employs measurements using collimator and a goniometer. A third calibration method uses diffractive optical elements (DOE to project holograms of well known pattern. In this paper these three calibration methods are compared empirically, especially in terms of accuracy. A camera has been calibrated with those methods mentioned above. All methods provide a set of distortion correction parameters as used by the photogrammetric software Australis. The resulting parameter values are very similar for all investigated methods. The three sets of distortion parameters are crosscompared against all three calibration methods. This is achieved by inserting the gained distortion parameters as fixed input into the calibration algorithms and only adjusting the exterior orientation. The RMS (root mean square of the remaining image coordinate residuals are taken as a measure of distortion correction quality. There are differences resulting from the different calibration methods. Nevertheless the measure is small for every comparison, which means that all three calibration methods can be used for accurate geometric calibration.

  5. Comparison of eigensolvers for symmetric band matrices.

    Science.gov (United States)

    Moldaschl, Michael; Gansterer, Wilfried N

    2014-09-15

    We compare different algorithms for computing eigenvalues and eigenvectors of a symmetric band matrix across a wide range of synthetic test problems. Of particular interest is a comparison of state-of-the-art tridiagonalization-based methods as implemented in Lapack or Plasma on the one hand, and the block divide-and-conquer (BD&C) algorithm as well as the block twisted factorization (BTF) method on the other hand. The BD&C algorithm does not require tridiagonalization of the original band matrix at all, and the current version of the BTF method tridiagonalizes the original band matrix only for computing the eigenvalues. Avoiding the tridiagonalization process sidesteps the cost of backtransformation of the eigenvectors. Beyond that, we discovered another disadvantage of the backtransformation process for band matrices: In several scenarios, a lot of gradual underflow is observed in the (optional) accumulation of the transformation matrix and in the (obligatory) backtransformation step. According to the IEEE 754 standard for floating-point arithmetic, this implies many operations with subnormal (denormalized) numbers, which causes severe slowdowns compared to the other algorithms without backtransformation of the eigenvectors. We illustrate that in these cases the performance of existing methods from Lapack and Plasma reaches a competitive level only if subnormal numbers are disabled (and thus the IEEE standard is violated). Overall, our performance studies illustrate that if the problem size is large enough relative to the bandwidth, BD&C tends to achieve the highest performance of all methods if the spectrum to be computed is clustered. For test problems with well separated eigenvalues, the BTF method tends to become the fastest algorithm with growing problem size.

  6. Multiple treatment comparisons in epilepsy monotherapy trials

    Directory of Open Access Journals (Sweden)

    Chadwick David W

    2007-11-01

    Full Text Available Abstract Background The choice of antiepileptic drug for an individual should be based upon the highest quality evidence regarding potential benefits and harms of the available treatments. Systematic reviews and meta-analysis of randomised controlled trials should be a major source of evidence supporting this decision making process. We summarise all available individual patient data evidence from randomised controlled trials that compared at least two out of eight antiepileptic drugs given as monotherapy. Methods Multiple treatment comparisons from epilepsy monotherapy trials were synthesized in a single stratified Cox regression model adjusted for treatment by epilepsy type interactions and making use of direct and indirect evidence. Primary outcomes were time to treatment failure and time to 12 month remission from seizures. A secondary outcome was time to first seizure. Results Individual patient data for 6418 patients from 20 randomised trials comparing eight antiepileptic drugs were synthesized. For partial onset seizures (4628 (72% patients, lamotrigine, carbamazepine and oxcarbazepine provide the best combination of seizure control and treatment failure. Lamotrigine is clinically superior to all other drugs for treatment failure but estimates suggest a disadvantage compared to carbamazepine for time to 12 month remission [Hazard Ratio (95% Confidence Interval = 0.87(0.73 to 1.04] and time to first seizure [1.29(1.13 to 1.48]. Phenobarbitone may delay time to first seizure [0.77(0.61 to 0.96] but at the expense of increased treatment failure [1.60(1.22 to 2.10]. For generalized onset tonic clonic seizures (1790 (28% patients estimates suggest valproate or phenytoin may provide the best combination of seizure control and treatment failure but some uncertainty remains about the relative effectiveness of other drugs. Conclusion For patients with partial onset seizures, results favour carbamazepine, oxcarbazepine and lamotrigine. For

  7. Comparison of elastic and inelastic analyses

    International Nuclear Information System (INIS)

    Ammerman, D.J.; Heinstein, M.W.; Wellman, G.W.

    1992-01-01

    The use of inelastic analysis methods instead of the traditional elastic analysis methods in the design of radioactive material (RAM) transport packagings leads to a better understanding of the response of the package to mechanical loadings. Thus, better assessment of the containment, thermal protection, and shielding integrity of the package after a structure accident event can be made. A more accurate prediction of the package response can lead to enhanced safety and also allow for a more efficient use of materials, possibly leading to a package with higher capacity or lower weight. This paper discusses the advantages and disadvantages of using inelastic analysis in the design of RAM shipping packages. The use of inelastic analysis presents several problems to the package designer. When using inelastic analysis the entire nonlinear response of the material must be known, including the effects of temperature changes and strain rate. Another problem is that there currently is not an acceptance criteria for this type of analysis that is approved by regulatory agencies. Inelastic analysis acceptance criteria based on failure stress, failure strain , or plastic energy density could be developed. For both elastic and inelastic analyses it is also important to include other sources of stress in the analyses, such as fabrication stresses, thermal stresses, stresses from bolt preloading, and contact stresses at material interfaces. Offsetting these added difficulties is the improved knowledge of the package behavior. This allows for incorporation of a more uniform margin of safety, which can result in weight savings and a higher level of confidence in the post-accident configuration of the package. In this paper, comparisons between elastic and inelastic analyses are made for a simple ring structure and for a package to transport a large quantity of RAM by rail (rail cask) with lead gamma shielding to illustrate the differences in the two analysis techniques

  8. Erosion resistance comparison of alternative surface treatments

    Science.gov (United States)

    Česánek, Z.; Schubert, J.; Houdková, Š.

    2017-05-01

    Erosion is a process characterized by the particle separation and the damage of component functional surfaces. Thermal spraying technology HP/HVOF (High Pressure / High Velocity Oxygen Fuel) is commonly used for protection of component surfaces against erosive wear. Alloy as well as cermet based coatings meet the requirements for high erosion resistance. Wear resistance is in many cases the determining property of required component functioning. The application suitability of coating materials is particularly influenced by different hardness. This paper therefore presents an erosion resistance comparison of alloy and cermet based coatings. The coatings were applied on steel substrates and were subjected to the erosive test using the device for evaluation of material erosion resistance working on the principle of centrifugal erodent flow. Abrasive sand Al2O3 with grain size 212-250 μm was selected as an erosive material. For this purpose, the specimens were prepared by thermal spraying technology HP/HVOF using commercially available powders Stellite 6, NiCrBSi, Cr3C2-25%NiCr, Cr3C2-25%CoNiCrAlY, Hastelloy C-276 and experimental coating TiMoCN-29% Ni. Erosion resistance of evaluated coatings was compared with erosive resistance of 1.4923 high alloyed steel without nitridation and in nitrided state and further with surface treatment using technology PVD. According to the evaluation, the resulting erosive resistance depends not only on the selected erodent and surface protection, but also on the erodent impact angle.

  9. SOCIAL RESPONSIBILITY VALUES: A CROSS COUNTRY COMPARISON

    Directory of Open Access Journals (Sweden)

    CATANA DOINA

    2011-07-01

    Full Text Available This empirical study aims at finding out how similar and/or different are the future Romanian and Slovenian managers in assessing the importance of organizations social responsibility values. The assumption of the research is that most of most of students in engineering and business will hold middle management position in the near future. The sample consists of 727 undergraduate and graduate students levels from Romania and Slovenia, two former socialist countries. The data has been collected between 2008 and 2009 in the framework of GLOBE student project , using a section of GLOBE III questionnaire, about the importance of CSR related values in critical decisions. The findings concern the similarities and significant differences between: 1 whole Romanian and Slovenian samples; 2 Romanian and Slovenian students in engineering; 3 Romanian and Slovenian students in business. Our findings revealed a trend toward convergence in the importance given to decisions effect on contribution to the economic welfare of the nation and local community, as well as on employees professional growth and development and on environment. The biggest difference between the groups concerns the decisions effect on firm profitability (the Romanians considering this value as more important in critical decisions than the Slovenians. The students in engineering proved to be a more homogeneous group, showing convergence in assessing the importance of eight out of fifteen social responsibility values. The biggest difference concerns the decisions effect on firm profitability (Romanians consider it as having higher importance in critical decisions than the Slovenians. Comparison of students in business revealed convergence in assessing the importance of employees professional growth and development and decisions effect on environment. The biggest positive difference concerns the same value of decisions effect on firm profitability. The Romanians are well behind Slovenians in

  10. Comparison of n-γ discrimination by zero-crossing and digital charge comparison methods

    International Nuclear Information System (INIS)

    Wolski, D.; Moszynski, M.; Ludziejewski, T.; Johnson, A.; Klamra, W.; Skeppstedt, Oe.

    1995-01-01

    A comparative study of the n-γ discrimination done by the digital charge comparison and zero-crossing methods was carried out for a 130 mm in diameter and 130 mm high BC501A liquid scintillator coupled to a 130 mm diameter XP4512B photomultiplier. The high quality of the tested detector was reflected in a photoelectron yield of 2300±100 phe/MeV and excellent n-γ discrimination properties with energy discrimination thresholds corresponding to very low neutron (or electron) energies. The superiority of the Z/C method was demonstrated for the n-γ discrimination method alone, as well as, for the simultaneous separation by the pulse shape discrimination and the time-of-flight methods down to about 30 keV recoil electron energy. The digital charge comparison method fails for a large dynamic range of energy and its separation is weakly improved by time-of-flight method for low energies. (orig.)

  11. KEY COMPARISON: Report on the Regional Comparison COOMET.AUV.A-K3

    Science.gov (United States)

    Barrera-Figueroa, Salvador; Nielsen, Lars; Rasmussen, Knud

    2007-01-01

    COOMET.AUV.A-K3 is a Regional Comparison that supplements the Key Comparison CCAUV.A-K3 organized by the CCAUV. The participating NMIs are GUM (Poland), INM (Romania), VNIIFTRI (Russia) and DP-NDI 'Systema' (Ukraine). The role of Pilot laboratory was undertaken by DPLADFM (Denmark). The measurements took place between May 2005 and February 2006. The time schedule was organized in a single star configuration. Initially, two LS2aP microphones were circulated. However, a sudden change of sensitivity of one of them forced the inclusion of an additional microphone. Nevertheless, the analysis was performed on all microphones involved. This report includes the measurement results from the participants, information about their calibration methods, and the analysis leading to the assignation of degrees of equivalence and the link to the CCAUV.A-K3. Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCAUV, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  12. Comparison of trauma on survivors of sexual assault and intimate ...

    African Journals Online (AJOL)

    2014-06-20

    Jun 20, 2014 ... Conclusion: The need for counselling and support for the survivors of both traumas was .... comparison of sexually- and physically-assaulted individuals ..... assault groups revealed no significant difference with regard.

  13. Comparison of the efficacy and safety of budesonide turbuhaler ...

    African Journals Online (AJOL)

    Comparison of the efficacy and safety of budesonide turbuhaler administered once daily with twice the dose of beclomethasone dipropionate using pressurised metered dose inhaler in patients with mild to moderate asthma.

  14. Tradeoffs Between Branch Mispredictions and Comparisons for Sorting Algorithms

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Moruz, Gabriel

    2005-01-01

    Branch mispredictions is an important factor affecting the running time in practice. In this paper we consider tradeoffs between the number of branch mispredictions and the number of comparisons for sorting algorithms in the comparison model. We prove that a sorting algorithm using O(dnlog n......) comparisons performs Omega(nlogd n) branch mispredictions. We show that Multiway MergeSort achieves this tradeoff by adopting a multiway merger with a low number of branch mispredictions. For adaptive sorting algorithms we similarly obtain that an algorithm performing O(dn(1+log (1+Inv/n))) comparisons must...... perform Omega(nlogd (1+Inv/n)) branch mispredictions, where Inv is the number of inversions in the input. This tradeoff can be achieved by GenericSort by Estivill-Castro and Wood by adopting a multiway division protocol and a multiway merging algorithm with a low number of branch mispredictions....

  15. Comparison of Cluster C personality disorders in couples with ...

    African Journals Online (AJOL)

    Comparison of Cluster C personality disorders in couples with normal divorce. ... Also purposeful sampling was used to select individuals. ... that the personality disorder group C, there is no significant difference between men and women.

  16. Comparison of the perception of ideal body images of Ghanaian ...

    African Journals Online (AJOL)

    Comparison of the perception of ideal body images of Ghanaian men and women. ... that Ghanaian men preferred Ghanaian women to be of the larger, traditional body size. ... of the preference of the opposite gender are significantly different.

  17. Learning from south–south comparison: the education systems of ...

    African Journals Online (AJOL)

    Erna Kinsey

    Graduate School of Education, Potchefstroom University, Private Bag X6001, Potchefstroom, ... The comparison with and learning from other countries are not done ..... the informal sector for 12%, and the remaining 29% were unemployed.

  18. Evaluation and Comparison of the Principal Component Analysis ...

    African Journals Online (AJOL)

    2012-08-01

    Aug 1, 2012 ... Comparison evaluation of performance indicates that, with PCA,. 80% of good GTE ... power generation Systems, Trains, Marine ... distributed around the median. Before ... GTE data is nonlinear and the distribution of the data ...

  19. Comparison of the body compositions in obese and nonobese ...

    African Journals Online (AJOL)

    2016-03-01

    Mar 1, 2016 ... of metabolic disorders, type 2 diabetes mellitus, obstructive sleep apnea ..... besides BMI in patients with COPD.[21] Similarly to our .... chronic obstructive pulmonary disease: Comparison with malnutrition in healthy smokers.

  20. Comparison between two possible CMS Barrel Muon Readout Architectures

    International Nuclear Information System (INIS)

    Aguayo, P.; Barcala, J.M.; Molinero, A.; Pablos, J.L.; Willmott, C.; Alberdi, J.; Marin, J.; Navarrete, J.; Romero, L.

    1997-01-01

    A comparison between two possible readout arquitectures for the CMS muon barrel readout electronics is presented, including various aspects like costs, reliability, installation, staging and maintenance. A review of the present baseline architecture is given in the appendix. (Author)