WorldWideScience

Sample records for electrocardiographic imaging ecgi

  1. Pediatric Electrocardiographic Imaging (ECGI) Applications

    Science.gov (United States)

    Silva, Jennifer N. A.

    2014-01-01

    Summary Noninvasive electrocardiographic imaging (ECGI) has been used in pediatric and congenital heart patients to better understand their electrophysiologic substrates. In this article we focus on the 4 subjects related to pediatric ECGI: 1) ECGI in patients with congenital heart disease and Wolff-Parkinson-White syndrome, 2) ECGI in patients with hypertrophic cardiomyopathy and pre-excitation, 3) ECGI in pediatric patients with Wolff-Parkinson-White syndrome, and 4) ECGI for pediatric cardiac resynchronization therapy. PMID:25722754

  2. Arrhythmia Mechanism and Scaling Effect on the Spectral Properties of Electroanatomical Maps With Manifold Harmonics.

    Science.gov (United States)

    Sanroman-Junquera, Margarita; Mora-Jimenez, Inmaculada; Garcia-Alberola, Arcadio; Caamano, Antonio J; Trenor, Beatriz; Rojo-Alvarez, Jose L

    2018-04-01

    Spatial and temporal processing of intracardiac electrograms provides relevant information to support the arrhythmia ablation during electrophysiological studies. Current cardiac navigation systems (CNS) and electrocardiographic imaging (ECGI) build detailed 3-D electroanatomical maps (EAM), which represent the spatial anatomical distribution of bioelectrical features, such as activation time or voltage. We present a principled methodology for spectral analysis of both EAM geometry and bioelectrical feature in CNS or ECGI, including their spectral representation, cutoff frequency, or spatial sampling rate (SSR). Existing manifold harmonic techniques for spectral mesh analysis are adapted to account for a fourth dimension, corresponding to the EAM bioelectrical feature. Appropriate scaling is required to address different magnitudes and units. With our approach, simulated and real EAM showed strong SSR dependence on both the arrhythmia mechanism and the cardiac anatomical shape. For instance, high frequencies increased significantly the SSR because of the "early-meets-late" in flutter EAM, compared with the sinus rhythm. Besides, higher frequency components were obtained for the left atrium (more complex anatomy) than for the right atrium in sinus rhythm. The proposed manifold harmonics methodology opens the field toward new signal processing tools for principled EAM spatiofeature analysis in CNS and ECGI, and to an improved knowledge on arrhythmia mechanisms.

  3. Electrocardiographic left ventricular hypertrophy without echocardiographic abnormalities evaluated by myocardial perfusion and fatty acid metabolic imaging

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi

    2000-01-01

    The pathophysiologic process in patients with electrocardiographic left ventricular hypertrophy with ST, T changes but without echocardiographic abnormalities was investigated by myocardial perfusion imaging and fatty acid metabolic imaging. Exercise stress 99m Tc-methoxy-isobutyl isonitrile (MIBI) imaging and rest 123 I-beta-methyl-p-iodophenyl pentadecanoic acid (BMIPP) imaging were performed in 59 patients with electrocardiographic hypertrophy including 29 without apparent cause including hypertension and echocardiographic hypertrophy, and 30 with essential hypertension. Coronary angiography was performed in 6 patients without hypertension and 4 with hypertension and biopsy specimens were obtained from the left ventricular apex from 6 patients without hypertension. Myocardial perfusion and 123 I-BMIPP images were classified into 3 types: normal, increased accumulation of the isotope at the left ventricular apex (high uptake) and defect. Transient perfusion abnormality and apical defect observed by 123 I-BMIPP imaging were more frequent in patients without hypertension than in patients with hypertension (32% vs. 17%, p=0.04671 in perfusion; 62% vs. 30%, p=0.0236 in 123 I-BMIPP). Eighteen normotensive patients with apical defect by 123 I-BMIPP imaging included 3 of 10 patients with normal perfusion at exercise, 6 of 10 patients with high uptake and 9 of 9 patients with perfusion defect. The defect size revealed by 123 I-BMIPP imaging was greater than that of the perfusion abnormality. Coronary stenoses were not observed and myocardial specimens showed myocardial disarray with hypertrophy. Moreover, 9 patients with hypertension and apical defects by 123 I-BMIPP showed 3 different types of perfusion. Many patients without hypertension show a pathologic process similar to hypertrophic cardiomyopathy. Perfusion and 123 I-BMIPP imaging are useful for the identification of these patients. (author)

  4. Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

    Science.gov (United States)

    Ghosh, Subham; Rhee, Edward K; Avari, Jennifer N; Woodard, Pamela K; Rudy, Yoram

    2008-08-26

    Cardiac memory refers to a change in ventricular repolarization induced by and persisting for minutes to months after cessation of a period of altered ventricular activation (eg, resulting from pacing or preexcitation in patients with Wolff-Parkinson-White syndrome). ECG imaging (ECGI) is a novel imaging modality for noninvasive electroanatomic mapping of epicardial activation and repolarization. Fourteen pediatric patients with Wolff-Parkinson-White syndrome and no other congenital disease, were imaged with ECGI a day before and 45 minutes, 1 week, and 1 month after successful catheter ablation. ECGI determined that preexcitation sites were consistent with sites of successful ablation in all cases to within a 1-hour arc of each atrioventricular annulus. In the preexcited rhythm, activation-recovery interval (ARI) was the longest (349+/-6 ms) in the area of preexcitation leading to high average base-to-apex ARI dispersion of 95+/-9 ms (normal is approximately 40 ms). The ARI dispersion remained the same 45 minutes after ablation, although the activation sequence was restored to normal. ARI dispersion was still high (79+/-9 ms) 1 week later and returned to normal (45+/-6 ms) 1 month after ablation. The study demonstrates that ECGI can noninvasively localize ventricular insertion sites of accessory pathways to guide ablation and evaluate its outcome in pediatric patients with Wolff-Parkinson-White syndrome. Wolff-Parkinson-White is associated with high ARI dispersion in the preexcited rhythm that persists after ablation and gradually returns to normal over a period of 1 month, demonstrating the presence of cardiac memory. The 1-month time course is consistent with transcriptional reprogramming and remodeling of ion channels.

  5. Electrocardiographic findings related to aging

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Shoichi; Yano, Katsuhiko

    1962-12-12

    More than 3000 electrocardiographic tracings for the ABCC-JNIH Adult Health Study Sample were studied to detect any specific abnormalities or nonspecific age changes in relation to possible radiation effects upon the cardiovascular system. The 4 comparison groups were studied with respect to the prevalence of electrocardiographic abnormalities and an electrocardiographic aging index which was defined to evaluate physiological change with age. Statistically significant differences were observed in the following aspects: In males aged 50 to 59, the prevalence of major electrocardiographic abnormalities was highest in the group located nearest the hypocenter. This was not observed in other age groups. In females, the prevalence of QRS high voltage was highest in Group 2 but low in Group 1. This trend was consistent in all age groups. These findings were not fully accounted for by differences in blood pressure, heart size, body weight or serum cholesterol values. In the age trend curve of the electrocardiographic aging index, a difference was observed among comparison groups in both sexes. This difference in electrocardiographic aging index is mainly attributed to T/sub I/ amplitude for males and R/sub II/ amplitude and QRS axis for females. Interpretation of these findings is rather difficult since very little has been known about radiation effects upon the cardiovascular system in humans. Further intensive studies are desired on the basis of the clues suggested in this report. 16 references, 3 figures, 31 tables.

  6. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  7. RTOS kernel in portable electrocardiograph

    Science.gov (United States)

    Centeno, C. A.; Voos, J. A.; Riva, G. G.; Zerbini, C.; Gonzalez, E. A.

    2011-12-01

    This paper presents the use of a Real Time Operating System (RTOS) on a portable electrocardiograph based on a microcontroller platform. All medical device digital functions are performed by the microcontroller. The electrocardiograph CPU is based on the 18F4550 microcontroller, in which an uCOS-II RTOS can be embedded. The decision associated with the kernel use is based on its benefits, the license for educational use and its intrinsic time control and peripherals management. The feasibility of its use on the electrocardiograph is evaluated based on the minimum memory requirements due to the kernel structure. The kernel's own tools were used for time estimation and evaluation of resources used by each process. After this feasibility analysis, the migration from cyclic code to a structure based on separate processes or tasks able to synchronize events is used; resulting in an electrocardiograph running on one Central Processing Unit (CPU) based on RTOS.

  8. RTOS kernel in portable electrocardiograph

    International Nuclear Information System (INIS)

    Centeno, C A; Voos, J A; Riva, G G; Zerbini, C; Gonzalez, E A

    2011-01-01

    This paper presents the use of a Real Time Operating System (RTOS) on a portable electrocardiograph based on a microcontroller platform. All medical device digital functions are performed by the microcontroller. The electrocardiograph CPU is based on the 18F4550 microcontroller, in which an uCOS-II RTOS can be embedded. The decision associated with the kernel use is based on its benefits, the license for educational use and its intrinsic time control and peripherals management. The feasibility of its use on the electrocardiograph is evaluated based on the minimum memory requirements due to the kernel structure. The kernel's own tools were used for time estimation and evaluation of resources used by each process. After this feasibility analysis, the migration from cyclic code to a structure based on separate processes or tasks able to synchronize events is used; resulting in an electrocardiograph running on one Central Processing Unit (CPU) based on RTOS.

  9. Electrocardiographic changes in obstructive sleep apnea syndrome.

    Science.gov (United States)

    Prakasa, Kalpana; Ahmed, Jehanara; Hasan, Syed; Yousef, Mahmoud; Shridharani, Sachin

    2005-01-01

    The acute electrocardiographic changes during apneic episodes in patients with sleep apnea are well known. Long-term electro-cardiographic changes in these patients are not well studied. We conducted a retrospective case-control study to assess the electrocardiographic changes in African-American patients with established obstructive sleep apnea syndrome (OSA). A significant percentage of patients with OSA had abnormal EKGs as compared to the control group. The effect of sleep apnea on the cardiovascular system is more complex in African-Americans due to higher prevalence of co-morbid conditions. Seventy-three percent of our patients with OSA had metabolic syndrome.

  10. Quantitative evaluations of left ventricular function obtained by electrocardiographically-gated magnetic resonance imaging

    International Nuclear Information System (INIS)

    Takeda, Tohru; Iida, Kaname; Sugishita, Yasuro; Anno, Izumi; Akisada, Masayoshi; Matsuda, Mitsuo; Akatsuka, Takao; Koseki, Susumu.

    1989-01-01

    Using electrocardiographically-gated magnetic resonance imaging, regional cardiac function was evaluated in 12 normal volunteers and in 10 cases of old myocardial infarction. The optimal short axis of the left ventricle was selected at the chordae tendineae level. The left ventricle was divided into 12 segments using a computer-aided system, and percentile shortening fraction (%SF) and percentile wall thickening (%WT) were calculated in each segment by the fixed coordinate method. In the normal volunteers, heterogeneity of both %FS and %WT was observed, ranging from 25±13% and 37±13%, respectively in the septal segment, to 49±13% and 60±21%, respectively in the posterior segment. In the cases of myocardial infarction, decreased %FS and %WT were detected at the affected regions. The abnormal regions revealed by %WT tended to be narrower than those revealed by %FS. Thus the MR technique at the optimal axis may be useful for quantitative evaluations of regional cardiac function. (author)

  11. Electrophysiological mechanisms of the SI SII SIII electrocardiographic morphology

    International Nuclear Information System (INIS)

    Bayes de Luna, A.; Carrio, I.; Subirana, M.T.; Torner, P.; Cosin, J.; Sagues, F.; Guindo, J.

    1987-01-01

    We studied three groups of individuals by means of spatial-velocity electrocardiograms and thallium-201 myocardial imaging to figure out the electrophysiological explanation of the SI SII SIII electrocardiographic morphology. We studied twelve healthy individuals without SI SII SIII, seven healthy individuals with SI SII SIII and fifteen patients with chronic obstructive pulmonary disease with SI SII SIII. The average values of the QRS-E and QRS-F intervals were higher in the second and third groups than in the first. One patient of the second group and thirteen of the third showed right ventricular enlargement. The slowing down of the right ventricular conduction explained the SI SII SIII morphology in normal individuals in more than half the cases. In patients with chronic obstructive pulmonary disease with SI SII SIII the conduction delay plays an important part in the electrogenesis of the right ventricular enlargement electrocardiographic morphology. We think that these observations can give further data about the electrophysiologic mechanism of the SI SII SIII morphology

  12. Electrocardiographic Findings in Brazilian Adults without Heart Disease: ELSA-Brasil.

    Science.gov (United States)

    Pinto, Marcelo Martins; Brant, Luisa C C; Padilha-da-Silva, José Luiz; Foppa, Murilo; Lotufo, Paulo A; Mill, José Geraldo; Vasconcelo-Silva, Paulo R; Almeida, Maria da Conceição C; Barreto, Sandhi Maria; Ribeiro, Antônio Luiz Pinho

    2017-11-01

    The electrocardiogram (ECG) is widely used in population-based studies. However, there are few studies on electrocardiographic findings in Latin America and in Brazil. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) comprised 15,105 participants (35-74 years) from six Brazilian capitals. To describe electrocardiographic findings in Brazilian adults without heart disease, stratified by sex, age and race/skin color. Cross-sectional study with baseline data of 11,094 adults (44.5% men) without heart disease from ELSA-Brasil. The ECGs were recorded with the Burdick Atria 6100 machine and stored at the Pyramis System. ECG analysis was automatically performed using the Glasgow University software. A descriptive analysis of heart rate (HR), P, QRS and T waves' duration, PR and QT intervals, and P, R and T axes was performed. After stratification by sex, race/color and age, the groups were compared by the Wilcoxon and Kruskal-Wallis test at a significance level of 5%. Linear regression models were used to evaluate the behavior of electrocardiographic parameters over age. Major electrocardiographic abnormalities defined by the Minnesota code were manually revised. Medians values of the electrocardiographic parameters were different between men and women: HR 63 vs. 66 bpm, PR 164 vs.158 ms, QT corrected 410 vs. 421 ms, QRS duration 92 vs. 86 ms, P-wave duration 112 vs. 108 ms, P-wave axis 54 vs. 57 degrees, R-wave axis 35 vs. 39 degrees, T-wave axis 39 vs. 45 degrees (p < 0.001 for all). The 2nd and the 98th percentiles of each variable were also obtained, and graphs were constructed to illustrate the behavior of the electrocardiographic findings over age of participants stratified by sex and race/skin color. The values for the electrocardiographic measurements herein described can be used as reference for Brazilian adults free of heart disease, stratified by sex. Our results suggest that self-reported race/skin color have no significant influence on

  13. Hypokalemia-induced pseudoischemic electrocardiographic changes and quadriplegia.

    Science.gov (United States)

    Mirijello, Antonio; Rinninella, Emanuele; De Leva, Francesca; Tosoni, Alberto; Vassallo, Gabriele; Antonelli, Mariangela; Addolorato, Giovanni; Landolfi, Raffaele

    2014-03-01

    Hypokalemia is a common biochemical abnormality. Severe hypokalemia can produce cardiac rhythm alterations and neurologic manifestations. Early detection and treatment allow clinician to prevent morbidity and mortality from cardiac arrhythmias and respiratory failure. Here, we describe a case of severe hypokalemia inducing pseudoischemic electrocardiographic (ECG) alterations and quadriplegia, in a patient affected by chronic diarrhea. Electrocardiographic alterations and neurologic manifestations completely disappeared after potassium replacement; however, prolonged potassium supplementation was required to achieve the normalization of plasmatic potassium levels. Consecutive figures show ECG improvement until normalization of ECG findings.

  14. Evaluation on the influence of electrocardiograph modulated milliampere on image quality and exposure dosage of volume CT heart scan

    International Nuclear Information System (INIS)

    Zhang Sen; Du Xiangke; Li Jianyin

    2006-01-01

    Objective: To find out whether the use of ECG modulated current (mA) will influence image quality and to decide whether the electrocardiograph (ECG) modulated mA will effectively reduce the exposure dosage. Methods: The cardiac pulsating phantom was set at three speed levels, i.e. high, medium, and low speed so as to simulate different heart rates. The phantom was scanned with ECG modulated mA turned on and off, and the exposure dosage of each scan sequence was documented. The images were reconstructed with reconstruction algorithm that matched the different levels of heart rate. CT values and their corresponding standard deviations at uniform areas on the images and the variation of the CT values at different locations were measured. The results from the two groups with and without ECG modulated mA were analyzed. Results: Under the same level of heart rate, the exposure dosage was remarkably reduced when the ECG modulated mA was on than when it was off. Statistical analysis showed no significant difference (P>0.05) between the images from the two groups. Conclusion: When scanning the heart with volume CT (VCT), the application of ECG modulated mA can effectively reduce the exposure dosage without sacrificing the image quality. (authors)

  15. Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Yanyan; Wu Guogeng; Zhou Cheng; Gao Jianhua; Jiao Sheng; Cao Huizhi

    2008-01-01

    Objective: To compare radiation dose and image quality between prospective electrocardiograph (ECG)-triggered axial scan and retrospective ECG-gated helical scan in coronary 64-slice CT angiography (CTA). Methods: Seventy-seven consecutive patients [group A. Average body mass index (BMI): 24.6, heart rate 0.05). Conclusion: Prospective ECG-triggered axial scan in 64-slice coronary CTA can significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. (authors)

  16. Frequency of electrocardiographic abnormalities in patients with psoriasis

    DEFF Research Database (Denmark)

    Hansen, Peter Riis; Juhl, Christian Rimer; Isaksen, Jonas Lynggaard

    2018-01-01

    Psoriasis is a chronic inflammatory disease associated with cardiovascular disease, for example, myocardial infarction, stroke, cardiovascular death, and arrhythmias. The resting electrocardiogram may carry prognostic information, but limited evidence is available of electrocardiographic findings...... beats/min, p = 0.007), but not after adjustment for smoking and body mass index. All other examined electrocardiographic variables, including QT interval corrected for heart rate with the Fridericia formula, PR interval, QRS duration, R axis, P-wave duration in lead V1, P-terminal force, J point...

  17. ELECTROCARDIOGRAPHIC ABNORMALITIES AMONG MEXICAN AMERICANS: CORRELATIONS WITH DIABETES, OBESITY, AND THE METABOLIC SYNDROME.

    Science.gov (United States)

    Queen, Saulette R; Smulevitz, Beverly; Rentfro, Anne R; Vatcheva, Kristina P; Kim, Hyunggun; McPherson, David D; Hanis, Craig L; Fisher-Hoch, Susan P; McCormick, Joseph B; Laing, Susan T

    2012-04-01

    Resting ischemic electrocardiographic abnormalities have been associated with cardiovascular mortality. Simple markers of abnormal autonomic tone have also been associated with diabetes, obesity, and the metabolic syndrome in some populations. Data on these electrocardiographic abnormalities and correlations with coronary risk factors are lacking among Mexican Americans wherein these conditions are prevalent. This study aimed to evaluate the prevalent resting electrocardiographic abnormalities among community-dwelling Mexican Americans, and correlate these findings with coronary risk factors, particularly diabetes, obesity, and the metabolic syndrome. Study subjects (n=1280) were drawn from the Cameron County Hispanic Cohort comprised of community-dwelling Mexican Americans living in Brownsville, Texas at the United States-Mexico border. Ischemic electrocardiographic abnormalities were defined as presence of ST/T wave abnormalities suggestive of ischemia, abnormal Q waves, and left bundle branch block. Parameters that reflect autonomic tone, such as heart rate-corrected QT interval and resting heart rate, were also measured. Ischemic electrocardiographic abnormalities were more prevalent among older persons and those with hypertension, diabetes, obesity, and the metabolic syndrome. Subjects in the highest quartiles of QTc interval and resting heart rate were also more likely to be diabetic, hypertensive, obese, or have the metabolic syndrome. Among Mexican Americans, persons with diabetes, obesity, and the metabolic syndrome were more likely to have ischemic electrocardiographic abnormalities, longer QTc intervals, and higher resting heart rates. A resting electrocardiogram can play a complementary role in the comprehensive evaluation of cardiovascular risk in this minority population.

  18. Clinical Electrocardiographic and Echocardiographic Features of ...

    African Journals Online (AJOL)

    Clinical Electrocardiographic and Echocardiographic Features of Atrial Fibrillation in Nigerians: An Analysis of 39 Patients Seen at the Lagos University Teaching Hospital. ... Congestive cardiac failure was present in 74% of the subjects with a mean NYHA class of about III. Embolic phenomenon was observed in 15% of the ...

  19. Exertional headache and coronary ischemia despite normal electrocardiographic stress testing.

    Science.gov (United States)

    Cutrer, F Michael; Huerter, Karina

    2006-01-01

    Exertional headaches may under certain conditions reflect coronary ischemia. We report the case of a patient seen in a neurology referral practice whose exertional headaches, even in the face of two normal electrocardiographic stress tests and in the absence of underlying chest pain were the sole symptoms of coronary ischemia as detected by Tc-99m Sestamibi testing SPECT stress testing. Stent placement resulted in complete resolution of headaches. Exertional headache in the absence of chest pain may reflect underlying symptomatic coronary artery disease (CAD) even when conventional electrocardiographic stress testing does not indicate ischemia.

  20. Third degree skin burns caused by a MRI conditional electrocardiographic monitoring system

    Directory of Open Access Journals (Sweden)

    Brix L

    2016-10-01

    Full Text Available Two unusual cases of third degree skin burns are reported using MRI approved electrocardiographic leads. This is very uncommon as it is most often the electrodes which are the source of heat related issues. Both patients were sedated due to pain related issues of their lower spine. The burns were caused by a combination of using a 3 Tesla MRI scanner and the inability to cry out during scanning. We would like to bring forward a message that even when using MRI conditional equipment, clinical staff must be extremely careful in order to secure safe image acquisition using MRI.

  1. Comparison of chest pain, electrocardiographic changes and thallium-201 scintigraphy during varying exercise intensities in men with stable angina pectoris

    International Nuclear Information System (INIS)

    Heller, G.V.; Ahmed, I.; Tilkemeier, P.L.; Barbour, M.M.; Garber, C.E.

    1991-01-01

    This study was performed to evaluate the presence of angina pectoris, electrocardiographic changes and reversible thallium-201 defects resulting from 2 different levels of exercise in 19 patients with known coronary artery disease and evidence of exercise-induced ischemia. The exercise protocols consisted of a symptom-limited incremental exercise test (Bruce protocol) followed within 3 to 14 days by a submaximal, steady-state exercise test performed at 70% of the maximal heart rate achieved during the Bruce protocol. The presence and time of onset of angina and electrocardiographic changes (greater than or equal to 0.1 mV ST-segment depression) as well as oxygen uptake, exercise duration and pressure-rate product were recorded. Thallium-201 (2.5 to 3.0 mCi) was injected during the last minute of exercise during both protocols, and the images were analyzed using both computer-assisted quantitation and visual interpretations. Incremental exercise resulted in anginal symptoms in 84% of patients, and electrocardiographic changes and reversible thallium-201 defects in all patients. In contrast, submaximal exercise produced anginal symptoms in only 26% (p less than 0.01) and electrocardiographic changes in only 47% (p less than 0.05), but resulted in thallium-201 defects in 89% of patients (p = not significant). The locations of the thallium-201 defects, when present, were not different between the 2 exercise protocols. These findings confirm the sequence of the ischemic cascade using 2 levels of exercise and demonstrate that the cascade theory is applicable during varying ischemic intensities in the same patient

  2. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG.

    Science.gov (United States)

    van Dam, Peter M; Gordon, Jeffrey P; Laks, Michael M; Boyle, Noel G

    2015-01-01

    Non-invasive electrocardiographic imaging (ECGI) of the cardiac muscle can help the pre-procedure planning of the ablation of ventricular arrhythmias by reducing the time to localize the origin. Our non-invasive ECGI system, the cardiac isochrone positioning system (CIPS), requires non-intersecting meshes of the heart, lungs and torso. However, software to reconstruct the meshes of the heart, lungs and torso with the capability to check and prevent these intersections is currently lacking. Consequently the reconstruction of a patient specific model with realistic atrial and ventricular wall thickness and incorporating blood cavities, lungs and torso usually requires additional several days of manual work. Therefore new software was developed that checks and prevents any intersections, and thus enables the use of accurate reconstructed anatomical models within CIPS. In this preliminary study we investigated the accuracy of the created patient specific anatomical models from MRI or CT. During the manual segmentation of the MRI data the boundaries of the relevant tissues are determined. The resulting contour lines are used to automatically morph reference meshes of the heart, lungs or torso to match the boundaries of the morphed tissue. Five patients were included in the study; models of the heart, lungs and torso were reconstructed from standard cardiac MRI images. The accuracy was determined by computing the distance between the segmentation contours and the morphed meshes. The average accuracy of the reconstructed cardiac geometry was within 2mm with respect to the manual segmentation contours on the MRI images. Derived wall volumes and left ventricular wall thickness were within the range reported in literature. For each reconstructed heart model the anatomical heart axis was computed using the automatically determined anatomical landmarks of the left apex and the mitral valve. The accuracy of the reconstructed heart models was well within the accuracy of the used

  3. Auscultatory and electrocardiographic characteristics of Crioulo horses

    Directory of Open Access Journals (Sweden)

    Jackson Schade

    2014-03-01

    Full Text Available In order to determine auscultatory and electrocardiographic characteristics of Crioulo horses, one hundred animals ranging between one and twenty-six years of age (21 stallions, nine geldings, 27 pregnant mares e 43 not pregnant mares were evaluated. The cardiac auscultation was performed during the clinical examination of the cardiovascular system, evaluating frequency, rate, normal and abnormal heart sounds (heart murmurs. The electrocardiographic examination followed the bipolar base-apex derivative system with animals at rest, by using an ECG-PC TEB equipment. The cardiac frequency, heart rate, morphology, duration, wave and complex amplitudes and interval durations were determined. The results were submitted to ANOVA and Tukey tests with an error probability of 5%. The cardiac auscultation revealed presence of functional systolic and diastolic murmur (10.00% and systolic murmur compatible with tricuspid regurgitation besides normal heart sounds S1 (100.0%, S2 (100.0%, S3 (19.0% and S4 (34.0%. The cardiac frequency obtained the average of 43.64 bpm, observing significative differences in relation to sexual and age factors and training level. The sinus rhythm was the most frequent (57.00%, followed by sinus tachycardia (38.00% and sinus arrhythmia (5.00%, being observed rhythm disturbances in 16% of tracings. The P and T waves were observed more frequently in their forms P bifida positive (95.00% and biphasic T (91.00%, being variable at tracing. There were also observed Q waves in 12.00% of the tracings. Thus, it was concluded that the auscultatory characteristics of Crioulo horses are according to the described in the literature for the species and the sexual factor, category, age factor and training level can influence some electrocardiographic parameters.

  4. Implications of normal exercise electrocardiographic results in patients with angiographically documented coronary artery disease. Correlation with left ventricular function and myocardial perfusion

    International Nuclear Information System (INIS)

    Hakki, A.H.; DePace, N.L.; Colby, J.; Iskandrian, A.S.

    1983-01-01

    The purpose of this study was to examine the incidence and implications of false-negative exercise electrocardiographic results among 216 consecutive patients with angiographically documented coronary artery disease (50 percent diameter narrowing or greater of one or more vessels). Exercise electrocardiography gave negative (false-negative) results in 23 patients and positive (true-positive) results in 102 patients, and were nondiagnostic in the rest. Exercise thallium-201 imaging was performed in 88 patients. The extent of coronary artery disease was quantitated by a scoring system that takes into consideration the degree and site of narrowing in the major vessels and their branches. The exercise heart rate was higher in patients with false-negative than in patients with true-positive exercise electrocardiographic results (161 +/- 18 versus 133 +/- 24 beats per minute, mean +/- SD; p less than 0.0001). Q-wave infarction was present in two patients (9 percent) with false-negative and 20 patients (20 percent) with true-positive exercise electrocardiographic results; left ventricular asynergy at rest was observed in 13 patients (57 percent) with false-negative and in 74 patients (74 percent) with true-positive results. Patients with false-negative results had less extensive coronary disease than did patients with true-positive results (score 5.8 +/- 3.6 versus 9.2 +/- 5.0; p . 0.0025). Angina during exercise was less frequent in patients with false-negative results (p less than 0.01). Abnormal exercise thallium-201 images were seen in 15 of 20 patients (75 percent) with false-negative results and in 56 of 68 patients (82 percent) with true-positive results

  5. Electrocardiographic Preexcitation and Risk of Cardiovascular Morbidity and Mortality

    DEFF Research Database (Denmark)

    Skov, Morten W.; Rasmussen, Peter V.; Ghouse, Jonas

    2017-01-01

    Background - The majority of available data on the clinical course of patients with ventricular preexcitation in the ECG originates from tertiary centers. We aimed to investigate long-term outcomes in individuals from a primary care population with electrocardiographic preexcitation. Methods and ...

  6. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy.

    Science.gov (United States)

    Lanjewar, Swapnil S; Chhabra, Lovely; Chaubey, Vinod K; Joshi, Saurabh; Kulkarni, Ganesh; Kothagundla, Chandrasekhar; Kaul, Sudesh; Spodick, David H

    2013-01-01

    The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration. We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1) were computed and compared between the two subgroups. There was no statistically significant difference in qualitative lung function (FEV1) between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy. The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.

  7. Electrocardiographic features of patients with earthquake related posttraumatic stress disorder

    OpenAIRE

    İlhan, Erkan; Kaplan, Abdullah; Güvenç, Tolga Sinan; Biteker, Murat; Karabulut, Evindar; Işıklı, Serhan

    2013-01-01

    AIM: To analyze electrocardiographic features of patients diagnosed with posttraumatic stress disorder (PTSD) after the Van-Erciş earthquake, with a shock measuring 7.2 on the Richter scale that took place in Turkey in October 2011.

  8. Female alcoholics: electrocardiographic changes and associated metabolic and electrolytic disorders

    Directory of Open Access Journals (Sweden)

    Borini Paulo

    2003-01-01

    Full Text Available OBJECTIVE: To identify the electrocardiographic changes and their associations with metabolic and electrolytic changes in female alcoholics. METHODS: The study comprised 44 female alcoholics with no apparent physical disorder. They underwent the following examinations: conventional electrocardiography; serologic tests for syphilis, Chagas' disease, and hepatitis B and C viruses; urinary pregnancy testing; hematimetric analysis; biochemical measurements of albumin, fibrinogen, fasting and postprandial glycemias, lipids, hepatic enzymes, and markers for tissue necrosis and inflammation. RESULTS: Some type of electrocardiographic change was identified in 33 (75% patients. In 17 (38.6% patients, more than one of the following changes were present: prolonged QTc interval in 24 (54.5%, change in ventricular repolarization in 11(25%, left ventricular hypertrophy in 6 (13.6%, sinus bradycardia in 4 (9.1%, sinus tachycardia in 3 (6.8%, and conduction disorder in 3 (6.8%. The patients had elevated mean serum levels of creatine phosphokinase, aspartate aminotransferases, and gamma glutamyl transferase, as well as hypocalcemia and low levels of total cholesterol and LDL-cholesterol. The patients with altered electrocardiograms had a more elevated age, a lower alcohol consumption, hypopotassemia, and significantly elevated levels of triglycerides, postprandial glucose, sodium and gamma glutamyl transferase than those with normal electrocardiograms. The opposite occurred with fasting glycemia, magnesium, and alanine aminotransferase. CONCLUSION: The electrocardiographic changes found were prolonged QTc interval, change in ventricular repolarization, and left ventricular hypertrophy. Patients with normal and abnormal electrocardiograms had different metabolic and electrolytic changes.

  9. Transient electrocardiographic abnormalities following blunt chest trauma in a child

    NARCIS (Netherlands)

    Udink ten Cate, Floris; Heerde, van Marc; Rammeloo, Lukas; Hruda, Jaroslav

    2008-01-01

    Blunt cardiac injury may occur in patients after suffering nonpenetrating trauma of the chest. It encompasses a wide spectrum of cardiac injury with varied severity and clinical presentation. Electrocardiographic abnormalities are frequently encountered. This article presents a case of a child

  10. Dynamic electrocardiographic changes in patients with arrhythmogenic right ventricular cardiomyopathy.

    LENUS (Irish Health Repository)

    Quarta, Giovanni

    2010-04-01

    Electrocardiographic (ECG) abnormalities of depolarisation and repolarisation contribute to the diagnostic criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC). The development of diagnostic ECG features were investigated in a genotyped cohort with ARVC to provide more sensitive markers of early disease.

  11. Infarct-like acute myocarditis: relation between electrocardiographic findings and myocardial damage as assessed by cardiac magnetic resonance imaging.

    Science.gov (United States)

    Nucifora, Gaetano; Miani, Daniela; Di Chiara, Antonio; Piccoli, Gianluca; Artico, Jessica; Puppato, Michela; Slavich, Gianaugusto; De Biasio, Marzia; Gasparini, Daniele; Proclemer, Alessandro

    2013-03-01

    Acute myocarditis (AM) may occasionally have an infarct-like presentation. The aim of the present study was to investigate the relation between electrocardiographic (ECG) findings in this group of patients and myocardial damage assessed by cardiac magnetic resonance imaging (MRI) with the late gadolinium enhancement (LGE) technique. Myocardial damage may be associated with ECG changes in infarct-like AM. Forty-one consecutive patients (36 males; mean age, 36 ± 12 years) with diagnosis of AM according to cardiac MRI Lake Louise criteria and infarct-like presentation were included. The relation between site of ST-segment elevation (STE), sum of STE (sumSTE), time to normalization of STE, and development of negative T wave with the extent of LGE (expressed as % of left ventricular mass [%LV LGE]), was evaluated. Most (80%) patients presented with inferolateral STE; mean sumSTE was 5 ± 3 mm. Normalization of STE occurred within 24 hours in 20 (49%) patients. Development of negative T wave occurred in 28 (68%) patients. Cardiac MRI showed LGE in all patients; mean %LV LGE was 9.6 ± 7.2%. Topographic agreement between site of STE and LGE was 68%. At multivariate analysis, sumSTE (β = 0.42, P 24 hours (β = 0.39, P 24 hours, and development of negative T wave) may help to identify patients with larger areas of myocardial damage. © 2012 Wiley Periodicals, Inc.

  12. Electrocardiographically and symptomatically silent myocardial ischemia during exercise testing

    International Nuclear Information System (INIS)

    Kurata, Chinori; Tawarahara, Kei; Sakata, Kazuyuki; Taguchi, Takahisa; Fukumoto, Yoshihiro; Kobayashi, Akira; Yamazaki, Noboru; Tanaka, Hiroshi

    1991-01-01

    Certain patients with coronary artery disease (CAD) may have neither ST depression nor chest pain during exercise despite the presence of myocardial ischemia. The frequency and characteristics of such electrocardiographically and symptomatically silent ischemia were studied in 171 patients with both angiographically documented CAD and scintigraphically documented ischemia. Fifty-six (33%) of 171 patients had neither ST depression nor chest pain (Group N), and 115 (67%) had ST depression and/or chest pain (Group P). The two groups were similar with respect to age, gender, the prevalence of prior infarction, and peak systolic blood pressure. Group N patients, however, had a higher mean peak heart rate and rate-pressure product, less severe scintigraphic ischemia, a lower lung thallium-201 uptake, and a smaller number of diseased vessels. Stepwise discriminant analysis showed a history of effort angina, lung thallium-201 uptake, and scintigraphic severity of ischemia to be significant discriminators between Groups N and P. In conclusion, electrocardiographically and symptomatically silent ischemia may be common during exercise in patients with CAD, and less severe ischemia may be one of important determinants. (author)

  13. Stop the Noise: A Quality Improvement Project to Decrease Electrocardiographic Nuisance Alarms.

    Science.gov (United States)

    Sendelbach, Sue; Wahl, Sharon; Anthony, Anita; Shotts, Pam

    2015-08-01

    As many as 99% of alarm signals may not need any intervention and can result in patients' deaths. Alarm management is now a Joint Commission National Patient Safety Goal. To reduce the number of nuisance electrocardiographic alarm signals in adult patients on the medical cardiovascular care unit. A quality improvement process was used that included eliminating duplicative alarms, customizing alarms, changing electrocardiography electrodes daily, standardizing skin preparation, and using disposable electrocardiography leads. In the cardiovascular care unit, the mean number of electrocardiographic alarm signals per day decreased from 28.5 (baseline) to 3.29, an 88.5% reduction. Use of a bundled approach to managing alarm signals decreased the mean number of alarm signals in a cardiovascular care unit. ©2015 American Association of Critical-Care Nurses.

  14. Analysis of Long-Term Electrocardiographic Data in a Rabbit Model of Heart Failure

    National Research Council Canada - National Science Library

    Schuckers, Stephanie

    2001-01-01

    ... was progressively induced with doxorubicin in a rabbit model, and electrocardiographic progressions from normal state to diseased state were continuously tracked, Automated methods for analyzing...

  15. Electrocardiographic evaluation in dogs of the Military Police of Rio de Janeiro

    Directory of Open Access Journals (Sweden)

    Alex Moreira de Lima

    2016-11-01

    Full Text Available ABSTRACT. Lima A.M., Ferreira L.T., Silva S.C., Jorge S.F., Ramos M.T., Pascon J.P.E., Moreira R.M. & Abidu-Figueiredo M. [Electrocardiographic evaluation in dogs of the Military Police of Rio de Janeiro.] Avaliação eletrocardiográfica em cães da Polícia Militar do Estado do Rio de Janeiro. Revista Brasileira de Medicina Veterinária, 38(Supl.2:61-66, 2016. Universidade Federal Rural do Rio de Janeiro, BR 465, Km 7, Seropédica, RJ 23897-970, Brasil. E-mail: marceloabidu@gmail.com In Rio de Janeiro, the Army, the Military Police and the Municipal Guard use dogs for routine patrol and detection of drugs, weapons, explosives and people. The most used breeds are German Shepherd, Labrador Retriever, Malinois Belgian Shepherd, Dutch Shepherd, and Doberman. Although these animals follow a protocol of physical activity, the kennel does not include a routine cardiovascular assessment and preventive hematologic exams. Forty four adult dogs were used, 13 Labrador Retrievers, 12 Malinois Belgian Shepherds, 10 German Shepherds, eight Dobermans and five Dutch Shepherds, all clinically healthy and from the Military Police Battalion of Action with Dogs of the Rio de Janeiro state. The animals underwent computed electrocardiographic and hematological evaluations. All electrocardiographic variables were correlated with body weight. Among the five breeds evaluated in the present study, only the Labrador breed showed a positive correlation between the duration of the QT interval and weight. The other electrocardiographic variables did not show any correlation with body weight. There were differences in the electrical shaft angle in Dobermann breed dogs. Labrador breed dogs showed the highest values for P wave amplitude and the breed Dobermann the lowest values. Breed dogs Labrador and German Shepherd showed the highest values for R wave amplitude and the breed Dobermann the lowest values. The QT segment as Labrador breed dogs is directly proportional to body

  16. Disappearance of electrocardiographic abnormalities associated with the arrhythmic pattern of a Barlow disease after surgical mitral valve repair

    Directory of Open Access Journals (Sweden)

    Matteo Augello

    2017-04-01

    Full Text Available We describe the case of a 46-year old female with a Barlow’s disease (MVP characterized by systolic curling of posterior left ventricular (LV wall + significant mitral annular disjunction + complex ventricular arrhythmias + syncope + inverted T waves in inferolateral leads in whom a successful surgical mitral valve rapair determined the disappearance not only of the echocardiographic but also the electrocardiographic abnormalities (in particular the inferolateral T waves inversion on basal electrocardiogram and the complex basal arrhythmic pattern. This case demonstrates that electrocardiographic abnormalities may disappear after the surgical correction of the mechanical stretch imposed on the inferior LV free wall by the prolapsing mitral valve leaflets. Electrocardiographic changes remain an important and easy marker to recognize for the identification of a high-risk subgroup of MVP patients.

  17. Diagnostic electrocardiographic dyad criteria of emphysema in left ventricular hypertrophy

    Directory of Open Access Journals (Sweden)

    Lanjewar SS

    2013-11-01

    Full Text Available Swapnil S Lanjewar,1 Lovely Chhabra,1 Vinod K Chaubey,1 Saurabh Joshi,1 Ganesh Kulkarni,1 Chandrasekhar Kothagundla,1 Sudesh Kaul,1 David H Spodick21Department of Internal Medicine, 2Department of Cardiovascular Medicine, Saint Vincent Hospital, University of Massachusetts Medical School, Worcester, MA, USABackground: The electrocardiographic diagnostic dyad of emphysema, namely a combination of the frontal vertical P-vector and a narrow QRS duration, can serve as a quasidiagnostic marker for emphysema, with specificity close to 100%. We postulated that the presence of left ventricular hypertrophy in emphysema may affect the sensitivity of this electrocardiographic criterion given that left ventricular hypertrophy generates prominent left ventricular forces and may increase the QRS duration.Methods: We reviewed the electrocardiograms and echocardiograms for 73 patients with emphysema. The patients were divided into two groups based on the presence or absence of echocardiographic evidence of left ventricular hypertrophy. The P-vector, QRS duration, and forced expiratory volume in one second (FEV1 were computed and compared between the two subgroups.Results: There was no statistically significant difference in qualitative lung function (FEV1 between the subgroups. There was no statistically significant difference in mean P-vector between the subgroups. The mean QRS duration was significantly longer in patients with left ventricular hypertrophy as compared with those without left ventricular hypertrophy.Conclusion: The presence of left ventricular hypertrophy may not affect the sensitivity of the P-vector verticalization when used as a lone criterion for diagnosing emphysema. However, the presence of left ventricular hypertrophy may significantly reduce the sensitivity of the electrocardiographic diagnostic dyad in emphysema, as it causes a widening of the QRS duration.Keywords: emphysema, electrocardiogram, left ventricular hypertrophy, chronic

  18. Cardiovascular studies Hiroshima 1958-1960: Report Number 1. Electrocardiographic findings in relation to the aging process formulation of the problem

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Shoichi; Yano, Katsuhiko

    1961-03-01

    As a part of ABCC's research program to review the general hypothesis that radiation exposure may accelerate aging processes, a comparative study now is being conducted on the pattern of age changes in electrocardiographic findings for the exposed and controls. In this report, emphasis is placed on the method of formulation of this study for statistical analysis. Two aspects of aging are considered: The frequency of abnormal electrocardiographic findings. Age changes found in normal electrocardiographic tracings. The first problem is an analysis of a three dimensional cross table of prevalence of electrocardiographic abnormalities by age, exposure group and a third factor (for instance, a socioeconomic or physiological factor). In the analysis of the second problem, an aging index was established in order to analyse effectively age changes in the electrocardiographic tracings. After a study of 22 measurements, QRS axis, Q-T interval, R/sub II/, T/sub I/, SV/sub 1/, RV/sub 1/, and RV/sub 5/ amplitudes were selected and their combination was derived to attain the highest correlation with age. Preliminary analysis was conducted for males for whom data collection had been completed. In the results so far obtained, no statistically significant differences were noted between the exposure groups. However, further detailed analysis should be conducted on these data together with data for females which are now being compiled. 18 references, 4 figures, 5 tables.

  19. Major Electrocardiographic Abnormalities According to the Minnesota Coding System Among Brazilian Adults (from the ELSA-Brasil Cohort Study).

    Science.gov (United States)

    Pinto-Filho, Marcelo M; Brant, Luisa C C; Foppa, Murilo; Garcia-Silva, Kaiser B; Mendes de Oliveira, Rackel Aguiar; de Jesus Mendes da Fonseca, Maria; Alvim, Sheila; Lotufo, Paulo A; Mill, José G; Barreto, Sandhi M; Macfarlane, Peter W; Ribeiro, Antonio L P

    2017-06-15

    The electrocardiogram is a simple and useful clinical tool; nevertheless, few studies have evaluated the prevalence of electrocardiographic abnormalities in the Latin American population. This study aims to evaluate the major electrocardiographic abnormalities according to the Minnesota coding system in Brazilian adults, stratified by gender, age, race, and cardiovascular risk factors. Data from 14,424 adults (45.8% men, age 35 to 74 years) were obtained at baseline of the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil), according to standardized protocol. The electrocardiogram were obtained with the Burdick Atria 6100 machine, stored on Pyramis System, automatically coded according to the Minnesota coding system by the Glasgow University software and then manually revised. Major abnormalities were more prevalent in men than women (11.3% and 7.9%, p <0.001). These differences were consistent through the different age groups, race, and number of cardiovascular risk factors. Electrocardiographic major abnormalities were more prevalent in black participants for both men (black: 15.1%, mixed: 10.4%, white: 11.1%, p = 0.001) and women (black: 10%, mixed: 7.6%, white: 7.2%, p = 0.004). In conclusion, in this large sample of Brazilian adults, the prevalence of major electrocardiographic abnormalities was higher among men, the elderly, black, and among people with more cardiovascular risk factors. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Insulated electrocardiographic electrodes. [without paste electrolyte

    Science.gov (United States)

    David, R. M.; Portnoy, W. A. (Inventor)

    1975-01-01

    An integrated system is disclosed including an insulated electrode and an impedance transformer which can be assembled in a small plastic housing and used for the acquisition of electrocardiographic data. The electrode may be employed without a paste electrolyte and may be attached to the body for extended usage without producing skin reaction. The electrode comprises a thin layer of suitable nontoxic dielectric material preferably deposited by radio frequency sputtering onto a conductive substrate. The impedance transformer preferably comprises an operational amplifier having an FET input stage connected in the unity gain configuration which provides a very low lower cut-off frequency, a high input impedance with a very small input bias current, a low output impedance, and a high signal-to-noise ratio.

  1. Electrocardiographic parameters of the American Miniature Horse: influence of age and sex

    Directory of Open Access Journals (Sweden)

    Bianca P. Santarosa

    2016-06-01

    Full Text Available Abstract: The veterinary cardiology has growing importance in equine medicine. There are studies of standardization of electrocardiographic parameters of many races, according to their stature and ability. However, no studies are in the literature with the American Miniature Horse. To evaluate the electrocardiogram (ECG tracing configuration of this breed at rest and to verify the influence of age and sex on ECG parameters, 203 horses including 143 females and 60 males were divided into four age groups (foals, yearlings, adults and elderly. Electrocardiographic parameters were performed by computerized electrocardiogram (TEB, and the parameters were evaluated in six leads of frontal plane (Lead I, II, III, aVR, aVL and aVF and base-apex (BA. Heart rates (HR decreased with increasing age were higher in males than in females. Sinus tachycardia followed by sinus arrhythmia was dominant in both sexes. The cardiac axis was higher in males and ranged between 120° and 150° for foals, 30° and 60° for yearlings and adults, and 60° and 90° for the elderly. The P wave was bifid in several animals. The P-wave amplitude and T-wave duration from lead II and BA were larger in males than in females. The majority of the animals exhibited ST segment depression and a negative T-wave. The most common QRS complex morphology was Qr. Differences were observed between the electrocardiographic tracings of males and females, and age influenced the ECG parameters. Therefore, this study established the ECG patterns for the American Miniature Horse breed and could be used to determine the influence of age and sex on several of the studied variables.

  2. Cardiovascular abnormalities in patients with oral cleft: a clinical-electrocardiographic-echocardiographic study

    Directory of Open Access Journals (Sweden)

    Gisele C.P. Leite

    2018-04-01

    Full Text Available OBJECTIVES: The present study aims to describe the clinical, electrocardiographic, and echocardiographic cardiological findings in a group of patients with oral clefts. METHODS: This is a prospective cross-sectional study on 70 children (age range from 13 days to 19 years with oral clefts who attended the multidisciplinary program of a university hospital from March 2013 to September 2014. The patients were evaluated by a pediatric cardiologist and underwent detailed anamnesis, physical examination, electrocardiogram, and echocardiogram. RESULTS: Sixty percent of the patients were male; 55.7% presented with cleft lip and palate, and 40.0% presented with health complaints. Comorbidities were found in 44.3%. Relevant pregnancy, neonatal, family and personal antecedents were present in 55.7%, 27.1%, 67.2%, and 24.3% of the patients, respectively. Regarding the antecedents, 15.2% of the patients presented with a cardiac murmur, 49.0% with a familial risk of developing plurimetabolic syndrome, and 6% with family antecedents of rheumatic fever. Electrocardiographic evaluation showed one case of atrioventricular block. Echocardiograms were abnormal in 35.7% of the exams, including 5 cases of mitral valve prolapse — one of which was diagnosed with rheumatic heart disease. CONCLUSION: The finding of a family risk of developing plurimetabolic syndrome and a diagnosis of rheumatic heart disease indicates that patients with oral clefts may be more prone to developing acquired heart disease. Thus, our findings highlight the importance of anamnesis and methodological triangulation (clinical-electrocardiographic-echocardiographic in the investigation of patients with oral clefts and emphasize that cardiological follow-up to evaluate acquired and/or rhythm heart diseases is necessary. This strategy permits comorbidity prevention and individualized planned treatment.

  3. Second statement of the working group on electrocardiographic diagnosis of left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Bacharova, Ljuba; Estes, E Harvey; Bang, Lia E

    2011-01-01

    The Working Group on Electrocardiographic Diagnosis of Left Ventricular Hypertrophy, appointed by the Editor of the Journal of Electrocardiology, presents the alternative conceptual model for the ECG diagnosis of left ventricular hypertrophy (LVH). It is stressed that ECG is a record of electrica...

  4. Electrocardiographic features of sarcomere mutation carriers with and without clinically overt hypertrophic cardiomyopathy

    DEFF Research Database (Denmark)

    Lakdawala, Neal K; Thune, Jens Jakob; Maron, Barry J

    2011-01-01

    In hypertrophic cardiomyopathy (HC), electrocardiographic (ECG) changes have been postulated to be an early marker of disease, detectable in sarcomere mutation carriers when left ventricular (LV) wall thickness is still normal. However, the ECG features of mutation carriers have not been fully...

  5. Exercise electrocardiographic variables: a critical appraisal

    International Nuclear Information System (INIS)

    Detrano, R.; Salcedo, E.; Passalacqua, M.; Friis, R.

    1986-01-01

    To compare four recently proposed methods of analyzing the exercise electrocardiogram with the conventional analysis of ST segment depression, 303 consecutive patients without myocardial infarction who had been referred for coronary arteriography underwent stress electrocardiography and stress thallium imaging. The specificity for the prediction of a greater than 50% coronary obstruction of 0.5, 1.0, 1.5 and 2.0 mm ST segment depression measured in the conventional way was 0.59, 0.73, 0.88 and 0.94, respectively. The specificity of a thallium perfusion defect was 0.79. Sensitivities of the conventional ST depressions, thallium defect, the change in the sum of the R amplitudes and the slope adjusted for heart rate increase were calculated and compared at the cited levels of specificity. R wave changes had a significantly lower sensitivity than did the conventionally analyzed ST depression at each level of specificity. Slope-adjusted ST depression had a slightly higher sensitivity than that of conventional ST depression only at a specificity of 0.73 (0.68 versus 0.65, p = 0.07). R wave-adjusted ST depression was significantly more sensitive than conventional ST depression only at a specificity of 0.94 (0.45 versus 0.36, p = 0.01). Heart rate-adjusted ST depression was more sensitive than conventional ST depression at all of the specificities except 0.59. This pattern of superior accuracy of heart rate-adjusted ST depressions was preserved for the prediction of multivessel coronary disease. Heart rate adjustment is a simpler and more accurate modification of the conventional electrocardiographic analysis than are the other three methods studied

  6. Giant T-U waves precede torsades de pointes in long QT syndrome: a systematic electrocardiographic analysis in patients with acquired and congenital QT prolongation

    NARCIS (Netherlands)

    Kirchhof, Paulus; Franz, Michael R.; Bardai, Abdennasser; Wilde, Arthur M.

    2009-01-01

    This study sought to identify electrocardiographic (ECG) criteria that are associated with initiation of torsades de pointes (TdP) in patients with acquired (a-) and congenital (c-) long QT syndrome (LQTS). Electrocardiographic criteria used as risk predictors for TdP commonly rely on a prolonged QT

  7. Study on mass survey for cardiovascular diseases. An analysis of the electrocardiographic findings of atomic bomb survivors

    International Nuclear Information System (INIS)

    Inoue, Noriko; Harada, Hisako; Nakamura, Kenji; Fujita, Keiko; Ishida, Sakurako; Sasaki, Hideo; Ito, Chikako; Tanaka, Gaku; Maeda, Ryo.

    1996-01-01

    Electrocardiographic findings obtained at authors' center in 1993 of 12,534 survivors (5,500 males and 7,034 females), aged 47-99 y, were analyzed in relation to irradiation conditions such as distance from the explosion site by Minnesota code to give the following results. The rate of survivors without abnormalities was higher in females than in males. In males and females, there was an increasing tendency with age of the appearance of QRS high potential, ischemic electrocardiographic abnormalities, bundle-branch block and arrhythmia. The frequency of appearance of ischemic abnormalities was correlated with sex and blood pressure but not with irradiation conditions. (H.O.)

  8. To identify Electrocardiographic changes in severely malnourished children

    Directory of Open Access Journals (Sweden)

    neeraj eKumar

    2015-09-01

    Full Text Available AbstractAims and objective: To identify myocardial changes in severely malnourished children.Material and method: This prospective, observational study enrolled 200 children between six months- five years of age who were fulfilling WHO criteria for severe malnutrition. The parents were duly informed and explained about the study and consent was taken. The material for the present study consisted of 200 cases (120 male and 80 female children suffering from severe protein energy malnutrition according to the mentioned criteria during the period of one year. The age group of the selected cases were divided in five groups viz. <1 years,1-2 years,2-3 years,3-4 years,4-5 years. A random selection of cases was done irrespectively of caste, creed, religion, sex and socioeconomic status etc.Results: 32% cases had flat P-wave on admission, out of which 75%. 84% of cases have increased Q-Tc-Interval at admission. S-T segment was depressed only in 8% of cases. 88% of cases have altered (flat to depressed T-wave at admission. All of these changes reverted to normal upon nutritional supplementation at discharge.Conclusion: The Electrocardiographic changes may be of help in assessing the severity and prognosis of severe acute malnutrition. The reversal of electrocardiographic changes was observed after dietary therapy. Reversibility of ECG changes suggests that the cardiac changes are not permanent in nature and will not have an effect in adult life. The cardiac status as denoted by heart rate remained same even after a fortnight, suggesting that a prolonged therapy and assessment of cardiac status is warranted even after fortnight therapy.

  9. Electrocardiographic reference values for healthy Netherland Dwarf rabbits and the influence of body position, age and gender

    Directory of Open Access Journals (Sweden)

    J. M. Chapel

    2017-12-01

    Full Text Available The aim of this study was to provide reference values for a single, popular breed of pet rabbit. Moreover, additional objectives were to determine whether sex, body position or age alter Netherland Dwarf rabbit electrocardiographic variables and whether the use of electrocardiographic filters affects those variables. Forty Netherland Dwarf rabbits were examined clinically and standard six-lead electrocardiograms (ECGs were recorded in sternal and then dorsal recumbency. At first power-line and anti-drift filters were used and then they were disabled. The following variables were measured in lead II: heart rate; P wave duration and amplitude; P-R interval; QRS duration; R wave amplitude (with and without filters; Q-T interval; T wave duration and amplitude; S-T segment; J-T duration; and mean electrical axis (MEA (with and without filters. MEA was determined by 3 different methods. After statistical processing of the data, our results showed that there were no significant differences between both recumbencies, with the exception of the J-T duration, which was higher in dorsal recumbency. The R wave amplitude using electrocardiographic filters showed significant differences between males (0.083 mV and females (0.115 mV; P<0.05; and between younger rabbits (0.108 mV and older rabbits (0.097 mV; P<0.05. These differences were not shown between R waves with filters disabled. Moreover, the strongest correlation was between 2 MEA methods without filters. MEA was more leftward in the pet rabbit than in other species (dog or cats. In conclusion, electrocardiography recording without electrocardiographic filters should be assessed when it is possible, and the specific ECGs characteristics for Netherland Dwarf rabbit should be taken into account.

  10. Sex Differences in Timeliness of Reperfusion in Young Patients With ST-Segment-Elevation Myocardial Infarction by Initial Electrocardiographic Characteristics.

    Science.gov (United States)

    Gupta, Aakriti; Barrabes, Jose A; Strait, Kelly; Bueno, Hector; Porta-Sánchez, Andreu; Acosta-Vélez, J Gabriel; Lidón, Rosa-Maria; Spatz, Erica; Geda, Mary; Dreyer, Rachel P; Lorenze, Nancy; Lichtman, Judith; D'Onofrio, Gail; Krumholz, Harlan M

    2018-03-07

    Young women with ST-segment-elevation myocardial infarction experience reperfusion delays more frequently than men. Our aim was to determine the electrocardiographic correlates of delay in reperfusion in young patients with ST-segment-elevation myocardial infarction. We examined sex differences in initial electrocardiographic characteristics among 1359 patients with ST-segment-elevation myocardial infarction in a prospective, observational, cohort study (2008-2012) of 3501 patients with acute myocardial infarction, 18 to 55 years of age, as part of the VIRGO (Variation in Recovery: Role of Gender on Outcomes of Young AMI Patients) study at 103 US and 24 Spanish hospitals enrolling in a 2:1 ratio for women/men. We created a multivariable logistic regression model to assess the relationship between reperfusion delay (door-to-balloon time >90 or >120 minutes for transfer or door-to-needle time >30 minutes) and electrocardiographic characteristics, adjusting for sex, sociodemographic characteristics, and clinical characteristics at presentation. In our study (834 women and 525 men), women were more likely to exceed reperfusion time guidelines than men (42.4% versus 31.5%; P ST elevation in lateral leads was an inverse predictor of reperfusion delay. Sex disparities in timeliness to reperfusion in young patients with ST-segment-elevation myocardial infarction persisted, despite adjusting for initial electrocardiographic characteristics. Left ventricular hypertrophy by voltage criteria and absence of prehospital ECG are strongly positively correlated and ST elevation in lateral leads is negatively correlated with reperfusion delay. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  11. Electrocardiographic abnormalities in opiate addicts.

    Science.gov (United States)

    Wallner, Christina; Stöllberger, Claudia; Hlavin, Anton; Finsterer, Josef; Hager, Isabella; Hermann, Peter

    2008-12-01

    To determine in a cross-sectional study the prevalence of electrocardiographic (ECG) abnormalities in opiate addicts who were therapy-seeking and its association with demographic, clinical and drug-specific parameters. In consecutive therapy-seeking opiate addicts, a 12-lead ECG was registered within 24 hours after admission and evaluated according to a pre-set protocol between October 2004 and August 2006. Additionally, demographic, clinical and drug-specific parameters were recorded. Included were 511 opiate-addicts, 25% female, with a mean age of 29 years (range 17-59 years). One or more ECG abnormalities were found in 314 patients (61%). In the 511 patients we found most commonly ST abnormalities (19%), QTc prolongation (13%), tall R- and/or S-waves (11%) and missing R progression (10%). ECG abnormalities were more common in males than in females (64 versus 54%, P seizures less often (16 versus 27%, P opiate addicts. The most frequent ECG abnormalities are ST abnormalities, QTc prolongation and tall R- and/or S-waves. ST abnormalities are associated with cannabis, and QTc prolongation with methadone and benzodiazepines.

  12. "Heart rate-dependent" electrocardiographic diagnosis of left ventricular hypertrophy.

    Science.gov (United States)

    Madias, John E

    2013-05-01

    A case is presented revealing the common phenomenon of heart rate-dependent diagnosis of electrocardiographic (ECG) diagnosis of left ventricular hypertrophy (LVH), which consists of satisfaction of LVH criteria only at faster rates whereas ECGs with a slow heart rate do not satisfy such criteria. The mechanism of the phenomenon has been attributed to the tachycardia-mediated underfilling of the left ventricle bringing the electrical "centroid" of the heart closer to the recording electrodes, which results in augmentation of the amplitude of QRS complexes, particularly in leads V2-V4. ©2012, The Author. Journal compilation ©2012 Wiley Periodicals, Inc.

  13. Electrocardiographic features of patients with earthquake related posttraumatic stress disorder

    Science.gov (United States)

    İlhan, Erkan; Kaplan, Abdullah; Güvenç, Tolga Sinan; Biteker, Murat; Karabulut, Evindar; Işıklı, Serhan

    2013-01-01

    AIM: To analyze electrocardiographic features of patients diagnosed with posttraumatic stress disorder (PTSD) after the Van-Erciş earthquake, with a shock measuring 7.2 on the Richter scale that took place in Turkey in October 2011. METHODS: Surface electrocardiograms of 12 patients with PTSD admitted to Van Erciş State Hospital (Van, Turkey) from February 2012 to May 2012 were examined. Psychiatric interviews of the sex and age matched control subjects, who had experienced the earthquake, confirmed the absence of any known diagnosable psychiatric conditions in the control group. RESULTS: A wide range of electrocardiogram (ECG) parameters, such as P-wave dispersion, QT dispersion, QT interval, Tpeak to Tend interval, intrinsicoid deflection durations and other traditional parameters were similar in both groups. There was no one with an abnormal P wave axis, short or long PR interval, long or short QT interval, negative T wave in lateral leads, abnormal T wave axis, abnormal left or right intrinsicoid deflection duration, low voltage, left bundle branch block, right bundle branch block, left posterior hemiblock, left or right axis deviation, left ventricular hypertrophy, right or left atrial enlargement and pathological q(Q) wave in either group. CONCLUSION: The study showed no direct effect of earthquake related PTSD on surface ECG in young patients. So, we propose that PTSD has no direct effect on surface ECG but may cause electrocardiographic changes indirectly by triggering atherosclerosis and/or contributing to the ongoing atherosclerotic process. PMID:23538549

  14. The Study of Electrocardiographic Findings in Patients with Organophosphate Poisoning

    Directory of Open Access Journals (Sweden)

    Morteza Rahbar Taromsari

    2013-02-01

    Full Text Available Background: Cardiac manifestations that occur in a majority of patients with organophosphate (OP poisoning may range from innocuous electrocardiographic manifestations, such as sinus tachycardia, to life-threatening complications, including cardiogenic pulmonary edema and myocardial necrosis. In this study, we evaluated the various electrocardiographic manifestations in patients with OP poisoning. Methods: This retrospective-descriptive study was performed by reviewing the medical records from all patients poisoned with organophosphate admitted to Razi Educational Hospital, Rasht, Iran, from April 2008 to March 2011. Patients with incomplete records were excluded from the study. Histories of all patients were collected and ECG analysis was conducted including the rate, rhythm, ST-T abnormalities, conduction defects, and measurement of PR and QT intervals by a cardiologist. Descriptive statistical analysis was conducted by SPSS software version18. Results: Of the total 100 patients (75 were male with OP poisoning that referred to the Emergency Ward of Razi Hospital, 63 patients presented ECG abnormalities. The mean age of the patients was 35.78 ± 12.91 years. The causes of poisoning were occupational in 71 patients, suicidal in 26 patients, and accidental in 3 patients. Sinus tachycardia (31% was the most common ECG abnormality, followed by non-specific ST-T changes (24%. Overall, mortality rate was 5% and all of the deceased patients presented changes in ECG. Conclusion: OP poisoning is associated with significant ECG abnormalities, especially tachycardia and non-specific ST-T changes.

  15. Prediction of single versus multivessel disease following myocardial infarction using 201-thallium scintigraphy and electrocardiographic stress testing

    International Nuclear Information System (INIS)

    Weiss, R.J.; Morise, A.P.; Raabe, D.S. Jr.; Sbarbaro, J.A.

    1983-01-01

    Fifty patients were evaluated who suffered a single myocardial infarction with graded electrocardiographic stress testing, 201-thallium myocardial perfusion imaging and coronary angiography to assess the role of noninvasive indices as predictors of single versus multivessel coronary artery disease. Multivessel involvement was defined angiographically as the presence of two or more major coronary arteries with at least a 70% intraluminal diameter narrowing. Multivessel disease was defined scintigraphically as the presence of stress and/or redistribution perfusion defects in the distribution of more than one coronary artery. The results of stress electrocardiography were not useful in differentiating patients with single (9/16 positive) versus multivessel (22/34 positive) disease. The degree of exercise-induced ST-segment depression was also not helpful. Stress 201-thallium imaging did offer limited additional information with correct predictions of multivessel disease in 21 of 26 patients. Predictions of single-vessel disease were accurate in 11 of 24 patients. Eleven of these 13 incorrect predictions of single-vessel disease were due to the relative insensitivity of the thallium stress image to perceive defect in the anterior wall when the left anterior descending artery had significant obstruction at catheterization. Further refinements of stress perfusion imaging are needed before this method can be used to reliably separate patients with single and multivessel disease after myocardial infarction

  16. Electrocardiographic artefacts mimicking atrial tachycardia resulted in unnecessary diagnostic and therapeutic measures

    OpenAIRE

    Y-Hassan, Shams; Sylv?n, Christer

    2013-01-01

    Electrocardiographic (ECG) artefacts may closely simulate both supraventricular and ventricular tachycardias. We describe a case initially diagnosed as rapid atrial fibrillation, based on 12-lead surface ECG (especially the limb leads) and monitor tracing. The arrhythmia was resistant to beta blockers. Because of the at times apparently regular rhythm, an esophageal ECG recording was performed, and adenosine was administered. When the presumed atrial fibrillation terminated after sodium pento...

  17. Portable electrocardiograph through android application.

    Science.gov (United States)

    De Oliveira, Igor H; Cene, V H; Balbinot, A

    2015-01-01

    An electrocardiograph was designed and implemented, being capable of obtaining electrical signals from the heart, and sending this data via Bluetooth to a tablet, in which the signals are graphically shown. The user interface is developed as an Android application. Because of the technological progress and the increasing use of full portable systems, such as tablets and cell phones, it is important to understand the functioning and development of an application, which provides a basis for conducting studies using this technology as an interface. The project development includes concepts of electronics and its application to achieve a portable and functional final project, besides using a specific programmable integrated circuit for electrocardiogram, electroencephalogram and electromyogram, the ADS1294. Using a simulator of cardiac signals, 36 different waveforms were recorded, including normal sinus rhythm, arrhythmias and artifacts. Simulations include variations of heart rate from 30 to 190 beats per minute (BPM), with variations in peak amplitude of 1 mV to 2 mV. Tests were performed with a subject at rest and in motion, observing the signals obtained and the damage to their interpretation due to the introduction of muscle movement artifacts in motion situations.

  18. Partial flip angle spin-echo imaging to obtain T1 weighted images with electrocardiographic gating

    International Nuclear Information System (INIS)

    Kawamitsu, Hideaki; Sugimura, Kazuro; Kasai, Toshifumi; Kimino, Katsuji

    1993-01-01

    ECG-gated spin-echo (SE) imaging can reduce physiologic motion artifact. However, it does not provide strong T 1 -weighted images, because the repetition time (TR) depends on heart rate (HR). For odd-echo SE imaging, T 1 contrast can be maximized by using a smaller flip angle (FA) of initial excitation RF pulses. We investigated the usefulness of partial FA SE imaging in order to obtain more T 1 -dependent contrast with ECG gating and determined the optimal FA at each heart rate. In computer simulation and phantom study, the predicted image contrast and signal-to-noise ratio (SNR) obtained for each FA (0∼180deg) and each HR (55∼90 beats per minute (bpm)) were compared with those obtained with conventional T 1 -weighted SE imaging (TR=500 ms, TE=20 ms, FA=90deg). The optimal FA was decreased by reducing HR. The FA needed to obtain T 1 -dependent contrast identical to that with T 1 -weighted SE imaging was 43deg at a HR of 65 bpm, 53deg at 70 bpm, 60deg at 75 bpm. This predicted FA were in excellent agreement with that obtained with clinical evaluation. The predicted SNR was decreased by reducing FA. The SNR of partial FA SE imaging at HR of 65 bpm (FA=43deg) was 80% of that with conventional T 1 -weighted SE imaging. However, this imaging method presented no marked clinical problem. ECG-gated partial FA SE imaging provides better T 1 -dependent contrast than conventional ECG-gated SE imaging, especially for Gd-DTPA enhanced imaging. (author)

  19. Hormonal, Electrolytic, and Electrocardiographic Evaluations in Bitches With Eutocia and Dystocia.

    Science.gov (United States)

    Simões, Carla Regina Barbieri; Vassalo, Flávia Gardilin; Lourenço, Maria Lúcia Gomes; de Souza, Fabiana Ferreira; Oba, Eunice; Sudano, Mateus José; Prestes, Nereu Carlos

    2016-12-01

    The objective of the study was to assess clinical alterations, electrocardiographic, hematological, biochemical, hemogasometric, electrolytic, and hormone plasma concentrations in bitches with eutocia and dystocia. Overall, 28 bitches (dystocia, n = 22 and eutocia, n = 6) were assessed. The evaluations were performed at 2 time points, M1 (1 hour prepartum-eutocia group and cesarean or clinical intervention-dystocia group) and M2 (postpartum-eutocia or dystocia group and anesthetic recovery-dystocia group). The main clinical finding was the hypothermia (mean: 36.9°C dystocia vs. 36.8°C eutocia). Sinus arrhythmia and tachycardia were the electrocardiographic parameters predominant in eutocia and sinus rhythm in dystocia group. The P wave amplitude, heart rate, creatinine concentration, hematocrit, and hemoglobin were increased in M1 (P dystocia and total T 3 concentrations were increased in M1 in both groups. Total T 4 was higher in dystocia during M1 and in dystocia during M2 in eutocia than in dystocia. We concluded that at 1 hour prepartum or pre-cesarean, there is an increase in heart rate in bitches with eutocia or dystocia, and this finding was correlated to thyroid hormone concentration. P 4 concentrations remained high during dystocia, and hematological and biochemical changes returned to normal after parturition. The evaluation of these parameters in pregnancy can be used as tool to prevent dystocia and consequent fetal death. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Electrocardiographic markers of ischemia during mental stress testing in postinfarction patients. Role of body surface mapping

    International Nuclear Information System (INIS)

    Bosimini, E.; Galli, M.; Guagliumi, G.; Giubbini, R.; Tavazzi, L.

    1991-01-01

    In patients with coronary artery disease, radionuclide investigations have documented a high incidence of mental stress-induced myocardial ischemia in the absence of significant electrocardiographic changes and/or angina. To investigate the causes of the low electrocardiographic sensitivity, we recorded body surface maps during mental arithmetic in 22 normal volunteers and 37 postinfarction patients with residual exercise ischemia. Myocardial perfusion was studied with thallium-201 or technetium-99 (SESTAMIBI) planar scans. In 14 patients, body surface maps were also recorded during atrial pacing at the heart rate values achieved during mental stress. While taking the body surface maps, the area from J point to 80 msec after this point (ST-80) was analyzed by integral maps, difference maps, and departure maps. The body surface mapping criteria for ischemia were a new negative area on the integral maps, a negative potential of more than 2 SD from mean normal values on the difference maps, and a negative departure index of more than 2. Scintigraphy showed asymptomatic myocardial hypoperfusion in 33 patients. Eight patients had significant ST segment depression. The ST-80 integral and difference maps identified 17 ischemic patients. Twenty-four patients presented abnormal departure maps. One patient presented ST depression and abnormal body surface maps without reversible tracer defect. In 14 of 14 patients, atrial pacing did not reproduce the body surface map abnormalities. The analyses of the other electrocardiographic variables showed that in patients with mental stress-induced perfusion defects, only changes of T apex-T offset (aT-eT) interval in Frank leads and changes of maximum negative potential value of aT-eT integral maps significantly differed from those of normal subjects

  1. The relationship of cardiovascular risk factors and electrocardiographic findings: Isfahan Healthy Heart Program

    OpenAIRE

    Nizal Sarrafzadegan; Masoumeh Sadeghi; Forough Khademi; Mohammad Arash Ramezani; Mohammad Hashemi Jazi

    2012-01-01

       BACKGROUND: Cardiovascular disease (CVD) is the leading cause of mortality worldwide. Various studies showed relationship between electrocardiographic (ECG) changes at rest and CVD mortality. Present study was performed to find the relation between ECG and CVD risk factors in an Iranian population.    METHODS: This cross-sectional study was performed on 3343 subjects aged ≥ 35 years from three provincial cities of Isfahan, Arak, and Najafabad. Demographic and lifesty...

  2. Chronic valvular disease: correlation between clinical, electrocardiographic, radiographic and echocardiographic aspects in dogs

    International Nuclear Information System (INIS)

    Soares, E.C.; Larsson, M.H.M.A.; Yamato, R.J.

    2005-01-01

    Echocardiographic aspects of chronic mitral valvular disease were studied and compared to physical, radiographic and electrocardiographic aspects. Seventy dogs were used, and clinical examination, thoracic radiography, electrocardiogram and echocardiogram were performed. Correlations between regurgitation severity with cardiac failure functional class and murmur intensity were observed. The electrocardiogram showed a low sensibility in detecting cardiac chamber enlargement, caused by mitral regurgitation. All the dogs with severe mitral regurgitation showed cardiomegaly according to thoracic radiographies

  3. Image Quality, Overall Evaluability, and Effective Radiation Dose of Coronary Computed Tomography Angiography With Prospective Electrocardiographic Triggering Plus Intracycle Motion Correction Algorithm in Patients With a Heart Rate Over 65 Beats Per Minute.

    Science.gov (United States)

    Pontone, Gianluca; Muscogiuri, Giuseppe; Baggiano, Andrea; Andreini, Daniele; Guaricci, Andrea I; Guglielmo, Marco; Fazzari, Fabio; Mushtaq, Saima; Conte, Edoardo; Annoni, Andrea; Formenti, Alberto; Mancini, Elisabetta; Verdecchia, Massimo; Fusini, Laura; Bonfanti, Lorenzo; Consiglio, Elisa; Rabbat, Mark G; Bartorelli, Antonio L; Pepi, Mauro

    2018-01-16

    Recently, a new intracycle motion correction algorithm (MCA) was introduced to reduce motion artifacts from heart rate (HR) in coronary computed tomography angiography (cCTA). The aim of the study was to evaluate the image quality, overall evaluability, and effective radiation dose (ED) of cCTA with prospective electrocardiographic (ECG) triggering plus MCA as compared with standard protocol with retrospective ECG triggering in patients with HR≥65 bpm. One hundred consecutive patients (67±10 y) scheduled for cCTA with 65Ethics Committee and a written informed consent was obtained from all patients. Image noise, signal to noise ratio, contrast to noise ratio, Likert image quality score (score 1, nondiagnostic; score 2, adequate; score 3, good; score 4, excellent), overall image evaluability, and ED were measured and compared between the 2 groups. Both vessel-based and patient-based analyses were evaluated. Student test or Wilcoxon test were used to evaluate differences of continuous variables, whereas the χ test was used to study differences with regard to categorical data. A P-value <0.05 was considered statistically significant. cCTA was successfully performed in all patients. In a segment-based model, group 1 compared with group 2 showed a lower rate of overall artifacts (67% vs. 83%; P<0.001) and motion artifacts (49% vs. 66%; P<0.001), resulting in a better Likert image quality score (2.83±1.03 vs. 2.37±1.02; P<0.01) and overall evaluability (85% vs. 75%; P<0.01). Group 1 showed a lower ED as compared with group 2 (3.1±1.9 vs. 11.9±3.3 mSv; P<0.01). MCA and cCTA with prospective ECG-triggering acquisition in patients with high HR improves image quality and overall evaluability compared with cCTA with standard retrospective ECG triggering.

  4. Causes of ischemic electrocardiographic changes in near drowning: A literature review.

    Science.gov (United States)

    Omar, Hesham R; Sprenker, Collin; Bosco, Gerardo; Mangar, Devanand; Camporesi, Enrico M

    2015-10-01

    Drowning is a main cause of accidental death among children and adolescents worldwide. Ischemic electrocardiographic (ECG) changes are often encountered in victims of near drowning. We reviewed the literature for near drowning cases reporting ischemic ECG changes to study the underlying etiology for these findings. Among the 8 cases included in the analysis, ischemic ECG changes were due to takotsubo cardiomyopathy (in elderly cases especially females); coronary artery spasm (in younger cases); or hypothermia effect on ECG; and, to a lesser extent, myocardial ischemia resulting from occlusive coronary artery disease. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Screening of young competitive athletes for the prevention of sudden cardiac death with a wireless electrocardiographic transmission device: a pilot study.

    Science.gov (United States)

    Cho, Jae Hyung; Selen, Mats A; Kocheril, Abraham G

    2015-08-11

    The 12-lead electrocardiographic screening for the prevention of sudden cardiac death in young competitive athletes is not cost-effective and thus not routinely recommended. We investigate whether a less expensive wireless electrocardiographic transmission device can be used to screen for the prevention of sudden cardiac death in this population. During pre-participation screening, twenty college football players underwent two electrocardiograms: a conventional 12-lead electrocardiogram and a wireless 9-lead electrocardiogram. We compared several electrocardiographic parameters (QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria, ST deviation and corrected QT interval) to determine the correlation. The QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria and corrected QT interval exhibited significant correlation between the two types of electrocardiograms (correlation coefficient 0.878, 0.630, 0.770 and 0.847, respectively with P values of 0.01, 0.003, 0.01 and 0.01, respectively). ST deviation in V1 was weakly correlated between the two types of electrocardiograms without statistical significance (correlation coefficient 0.360 with a P value of 0.119). Our newly developed wireless 9-lead electrocardiogram demonstrated significant correlations with a conventional 12-lead electrocardiogram in terms of QRS duration, left ventricular hypertrophy and corrected QT interval.

  6. Classified study and clinical value of the phase imaging features

    International Nuclear Information System (INIS)

    Dang Yaping; Ma Aiqun; Zheng Xiaopu; Yang Aimin; Xiao Jiang; Gao Xinyao

    2000-01-01

    445 patients with various heart diseases were examined by the gated cardiac blood pool imaging, and the phase was classified. The relationship between the seven types with left ventricular function index, clinical heart function, different heart diseases as well as electrocardiograph was studied. The results showed that the phase image classification could match with the clinical heart function. It can visually, directly and accurately indicate clinical heart function and can be used to identify diagnosis of heart disease

  7. Electrocardiographic evaluation of two anesthetic combinations in dogs

    Directory of Open Access Journals (Sweden)

    Tárraga K.M.

    2000-01-01

    Full Text Available This study aimed to investigate electrocardiographic changes in dogs aged 5 years or more submitted to two anesthetic combinations: atropine, levomeprazine, thiopental and halothane (ALTH, and atropine, tiletamine and zolazepam (ATZ. Forty dogs (24 males/16 females weighing 5-24kg, were used. Dogs had no cardiac problems and were submitted to tartarectomy. All animals were submitted to two electrocardiograms (ECG, one before anesthesia and other immediately before surgery. The dogs were divided into two groups: group 1 received ALTH and group 2 received ATZ. Alterations in the ST segment, T wave, cardiac rhythm and a significant reduction of vagal tonus index were observed in both groups, but in group 2 a significant reduction of the PR and QT intervals and an increase in heart rate were also observed. These data suggest that the ALTH combination caused fewer changes in the ECG than the ATZ combination.

  8. Evaluation of ECG criteria for left ventricular hypertrophy before and after aortic valve replacement using magnetic resonance Imaging

    NARCIS (Netherlands)

    Beyerbacht, Hugo P.; Bax, Jeroen J.; Lamb, Hildo J.; van der Laarse, Arnoud; Vliegen, Hubert W.; de Roos, Albert; Zwinderman, Aeilko H.; van der Wall, Ernst E.

    2003-01-01

    PURPOSE: Evaluation of different electrocardiographic criteria for left ventricular hypertrophy (ECG-LVH criteria) using left ventricular mass index (LVMI) determined by magnetic resonance imaging (MRI). In addition, the relation between LVMI regression after aortic valve replacement and

  9. Uncontrolled hypertension is associated with coronary artery calcification and electrocardiographic left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Nielsen, Mette Lundgren; Pareek, Manan; Gerke, O

    2015-01-01

    We conducted a 1:2 matched case-control study in order to evaluate whether the prevalence of coronary artery calcium (CAC) and electrocardiographic left ventricular hypertrophy (LVH) or strain was higher in patients with uncontrolled hypertension than in subjects from the general population......, and evaluate the association between CAC and LVH in patients with uncontrolled hypertension. Cases were patients with uncontrolled hypertension, whereas the controls were random individuals from the general population without cardiovascular disease. CAC score was assessed using a non-contrast computed...

  10. Flattening of the electrocardiographic T-wave is a sign of proarrhythmic risk and a reflection of action potential triangulation

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed; Graff, Claus; Kanters, J.K.

    2013-01-01

    Drug-induced triangulation of the cardiac action potential is associated with increased risk of arrhythmic events. It has been suggested that triangulation causes a flattening of the electrocardiographic T-wave but the relationship between triangulation, T-wave flattening and onset of arrhythmia ...

  11. Comparative analysis of a portable smartphone­based electrocardiograph (D­Heart® versus standard 6­leads electrocardiograph in the canine patient.

    Directory of Open Access Journals (Sweden)

    Alice Savarese

    2017-05-01

    Full Text Available D-Heart® is a portable, smartphone-based device, which streams tracing via Bluetooth, enabling multiple leads electrocardiograms (ECGs acquisition, currently used in human cardiology (Maurizi et al. 2017. The aim was to determine the accuracy of D­Heart® compared with the gold standard non­portable 6­lead electrocardiograph in the evaluation of cardiac rhythm in dogs. Standard 6­lead and D­Heart® ECGs were acquired in conscious dogs. Concordance between methods was assessed by weighted k Cohen index, with its relative significance, taking as end point variable standard 6­lead ECG group. Bland ­ Altman method (95% confidence level was applied for P, PR, QRS, T and QT. Since differences didn’t follow a normal distribution, a non­parametric approach was used to determine limits of agreement. P was significant when < 0.05 (Maurizi et al. 2017. Amplitude of waves was not considered because currently the software doesn’t allow voltage variation. 115 dogs of different weights and breeds admitted to the Cardiology Service of DIMEVET were enrolled. Mean age was 7,5±4 years. Most were intact males (45%, n=51. The most represented breed was mongrel (27%, n=32. Weighted Cohen's kappa test demonstrated excellent concordance in the evaluation of the heart rhythm (0.989, p<0.001, for ST segment morphology (0.991, p<0,001 and for T wave morphology (0.838, p=0.040. There was a 100% concordance in P morphology determination. P, PR, QRS, T and QT intervals comparison with Bland­Altman showed an extremely good concordance for D­Heart® measurements (95% limit of agreement ±0.9 ms for P, ±10 ms for PR, ±35 ms for QRS, ±5 ms for T wave. Less concordance resulted for QT (±80 ms. In Conclusion, D­Heart® proved effective accurate recording of ECG comparable to standard 6­lead electrocardiographs, opening new perspectives to improve diagnostic tools in veterinary cardiology. Future perspective will be the development of a telecardiology network

  12. Electrocardiographic findings in athletes: the prevalence of left ventricular hypertrophy and conduction defects.

    Science.gov (United States)

    Langdeau, J B; Blier, L; Turcotte, H; O'Hara, G; Boulet, L P

    2001-06-01

    To determine whether there are electrocardiographic differences or distinctive abnormalities between athletes and sedentary subjects, and to verify the relationship between vagal activity measured by heart rate variability (SD of all normal-to-normal intervals [SDNN]) and possible electrocardiographic abnormalities. Resting electrocardiograms and heart rate variability measurements were performed separately during a single visit on 100 athletes and 50 nonathlete control subjects aged 18 to 55 years. The athletes were from the following various sports disciplines: long-distance running, mountain biking, cross-country skiing, biathlon, speed skating, swimming and triathlon. There were significantly longer RR intervals, PR intervals and QT intervals in athletes than in control subjects (all P0.05). The prevalence of left ventricular hypertrophy (LVH) and incomplete right bundle branch block (IRBBB) was 10% and 7%, respectively, in athletes, but these conditions were absent in control subjects; among athletes, 2% presented with both conditions. LVH and IRBBB were more common among long-distance runners (six of 14 and four of 14, respectively) and could be attributed to normal, long term adaptation to intense, repeated exercise. LVH was related to age (P=0.04), whereas IRBBB was influenced by the number of years of training in the respective sports discipline (P=0.03). The mean SDNN value was significantly more elevated in athletes (P=0.0001), reflecting a higher parasympathetic tone than in sedentary control subjects. However, there was no relationship between vagal activity and LVH or IRBBB (both P>0.05).

  13. Electrocardiographic Changes in Certain Cardiovascular Physiological and Pathological Settings. Impact on Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Dimitar Simov

    2016-03-01

    Full Text Available Review on electrocardiographic changes provoked by aging, diagnostic tests, cardiac surgery, hemodialysis, diabetes, etc., is the objective of the current material. Several electrocardiographic (ECG parameters that are well known risk markers of arrhythmias, incidental heart failure and sudden cardiac death (SCD are discussed: QRS amplitude, QRS morphology, QRS duration, QRS alternans, T-wave amplitude, T-wave morphology, T-wave alternans, negative T-waves, 3D-spatial angle between maximal QRS and T vectors of the vectorcardiographic loops, ST-segment elevation, QT-interval dispersion, and heart rate. All reviewed parameters are compared with the results on the ECG-alterations, induced by coronary artery bypass grafting (CABG surgery. Two parameters showed an improvement in the patients' condition: QRS-T angle and cardiac autonomic innervation while two others (T-wave alternans and heart rate indicated deterioration. We tend to assume that the deterioration in this early post-operative period is an effect of the post-surgery trauma. We speculate that this effect will fade away in a period of a month and more after surgery, and we intend to conduct such a research in the future. The analysis of ECG's changes will help to better assess the impact of the CABG surgery.

  14. Exercise electrocardiographic responses and serum cystatin C levels among metabolic syndrome patients without overt diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Tanindi A

    2011-02-01

    Full Text Available Asli Tanindi1 Hilal Olgun1 Ayse Tuncel2 Bulent Celik3 Hatice Pasaoglu2 Bulent Boyaci11Department of Cardiology, 2Department of Medical Biochemistry, Faculty of Medicine, 3Department of Statistics, Faculty of Health Sciences, Gazi University, Ankara, TurkeyObjectives: An impaired heart rate response during exercise (chronotropic incompetence and an impaired heart rate recovery (HRR after exercise are predictors of cardiovascular risk and mortality. Cystatin C is a novel marker for cardiovascular disease. We aimed to investigate exercise electrocardiographic responses in patients with metabolic syndrome who were without overt diabetes mellitus, in addition to the association of serum cystatin C levels with the exercise electrocardiographic test results.Method: Forty-three consecutive patients admitted to a cardiology outpatient clinic without angina pectoris were recruited if they met criteria for metabolic syndrome but did not have overt diabetes mellitus. Serum cystatin C levels were measured, and all participants underwent exercise electrocardiographic testing. Patients who were found to have ischemia had a coronary angiography procedure.Results: The mean cystatin C level of patients was higher in metabolic syndrome group than healthy controls (610.1 ± 334.02 vs 337.3 ± 111.01 µg/L; P < 0.001. The percentage of patients with ischemia confirmed by coronary angiography was 13.9% in the metabolic syndrome group. Cystatin C levels in the ischemic patients of the metabolic syndrome group were higher than that in nonischemic patients (957.00 ± 375.6 vs 553.8 ± 295.3 µg /L; P = 0.005. Chronotropic incompetence was observed in 30.2% of the patients with metabolic syndrome compared with 16.7% in the control group (P = 0.186. Chronotropic response indices were 0.8 ± 0.18 versus 0.9 ± 0.10 for the two groups, respectively (P = 0.259. HRR was significantly lower in the metabolic syndrome patients compared with the controls (20.1 ± 8.01 vs 25.2

  15. Hidradenitis Suppurativa and electrocardiographic changes - a cross-sectional population study

    DEFF Research Database (Denmark)

    Juhl, C R; Miller, I M; Jemec, G B

    2018-01-01

    BACKGROUND: Hidradenitis Suppurativa (HS) is a chronic, inflammatory skin disease, recently associated with metabolic syndrome, subclinical atherosclerosis and increased risk of cardiovascular disease. OBJECTIVES: The aim of the study was to investigate the hitherto unknown electrocardiographic c...... resting electrocardiograms. We investigated the difference in means by unpaired t-test or the analysis of variance (ANOVA) test. RESULTS: Heart rate was significantly higher (mean difference: 2.3 bpm [1.2:3.4] p..., there was no significant difference (0.3 bpm [-0.7:1.4] p=0.52). Severe HS was significantly associated with increased heart rate across all models (2.9 bpm [0.7:5.1] p=0.01). Mean QRS-duration was significantly shorter in the mild HS group, but not in the moderate- and severe HS groups CONCLUSION: Mean resting heart rate...

  16. Three-dimensional surface reconstruction imaging for evaluation of congenital heart disease from ECG-triggered MR images

    International Nuclear Information System (INIS)

    Vannier, M.W.; Laschinger, J.; Knapp, R.H.; Gutierrez, F.R.; Gronnemeyer, S.A.

    1987-01-01

    Three-dimensional surface reconstruction images of the heart and great vessels were produced from contiguous sequences of electrocardiographically triggered MR images in 25 patients with congenital heart disease and in three healthy subjects. The imaging data were semiautomatically processed to separate the epicardial and endocardial surfaces and to define the outline of the enclosed blood volumes on a section by section basis. Images were obtained at 5-mm intervals in patients aged 3 months to 30 years with anomalies of the great vessels, tetralogy of Fallot, septal defects, pulmonary atresia, and other congenital heart malformations. The results were used to facilitate the surgical treatment of these patients and were compared with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. These surface reconstruction images were useful for communicating the results of diagnostic examinations to cardiac surgeons, for sizing and location of intracardiac defects, for imaging the pulmonary venous drainage, and for assessing regional and global function

  17. Electrocardiographic Manifestations of Benzodiazepine Toxicity

    Directory of Open Access Journals (Sweden)

    Nahid Kazemzadeh

    2014-11-01

    Full Text Available Background: The aim of this study was to evaluate and compare the clinical and electrocardiographic (ECG manifestations of benzodiazepines (BZs. Methods: In this retrospective study, all BZ-poisoned patients hospitalized at Loghman Hakim Hospital between September 2010 and March 2011 were evaluated. Patients’ information including age, sex, time elapsed between the ingestion and presentation, and type of the BZ used were extracted from the patients' charts and recorded. ECGs on presentation to the emergency department (ED were evaluated and parameters such as PR interval, QRS duration, corrected QT, amplitude of S wave in lead I, height of R wave and R/S ratio in the lead aVR were also measured and recorded. Results: Oxazepam, chlordiazepoxide, lorazepam, alprazolam, diazepam, and clonazepam were ingested by 9 (3%, 13 (4.4%, 29 (9.9%, 105 (35.8%, 65 (22.2%, and 72 (24.6% patients, respectively. Mean PR interval was reported to be 0.16 ± 0.03 sec and PR interval of greater than 200 msec was detected in 12 (4.5% patients. Mean QRS duration was 0.07 ± 0.01sec and QRS≥120 msec was observed in 7 (2.6% cases. Conclusion: Diazepam is the only BZ that does not cause QRS widening and oxazepam is the only one not causing PR prolongation. It can be concluded that if a patient refers with a decreased level of consciousness and accompanying signs of BZ toxicity, QRS widening in ECG rules out diazepam, whereas PR prolongation rules out oxazepam toxicity.

  18. Magnetic resonance imaging of the normal and abnormal pulmonary hila

    International Nuclear Information System (INIS)

    Webb, W.R.; Gamsu, G.; Stark, D.D.; Moore, E.H.

    1984-01-01

    Magnetic resonance (MR) images of the hila were reviewed in 25 normal subjects and 12 patients with unilateral or bilateral hilar masses. On spin echo MR images in normal patients, collections of soft tissue large enough to be confused with an abnormally enlarged lymph node were seen in three locations. In patients with a hilar mass, the mass was differentiated from hilar vasculature more easily using MR than contrast-enhanced CT. However, because the spatial resolution of MR is inferior to that of CT, bronchi were difficult to evaulate using MR. Electrocardiographic-gated images showed better resolution of hilar structures but may not be necessary for large masses

  19. Telefetalcare: a first prototype of a wearable fetal electrocardiograph.

    Science.gov (United States)

    Fanelli, A; Signorini, M G; Ferrario, M; Perego, P; Piccini, L; Andreoni, G; Magenes, G

    2011-01-01

    Fetal heart rate monitoring is fundamental to infer information about fetal health state during pregnancy. The cardiotocography (CTG) is the most common antepartum monitoring technique. Abdominal ECG recording represents the most valuable alternative to cardiotocography, as it allows passive, non invasive and long term fetal monitoring. Unluckily fetal ECG has low SNR and needs to be extracted from abdominal recordings using ad hoc algorithms. This work describes a prototype of a wearable fetal ECG electrocardiograph. The system has flat band frequency response between 1-60 Hz and guarantees good signal quality. It was tested on pregnant women between the 30(th) and 34(th) gestational week. Several electrodes configurations were tested, in order to identify the best solution. Implementation of a simple algorithm for FECG extraction permitted the reliable detection of maternal and fetal QRS complexes. The system will allow continuative and deep screening of fetal heart rate, introducing the possibility of home fetal monitoring.

  20. How many electrocardiographic leads are required for exercise treadmill tests

    International Nuclear Information System (INIS)

    Miller, T.D.; Desser, K.B.; Lawson, M.

    1987-01-01

    Forty-four consecutive patients who had perfusion defects on thallium-201 scanning and positive exercise treadmill tests were prospectively studied. Thirty-eight (86%) subjects had diagnostic ST segment changes in lead V5, 37 (84%) in lead V4, and 44 (100%) in either lead V4, V5 or both. Thirty patients had ST segment changes in the inferior leads, 20 in lead aVR, and only four in lead I and/or aVL. All of these latter subjects had diagnostic ST segments in lead V4 and/or V5. It is concluded that: combined electrocardiographic leads V4 and V5 detect the vast majority of ischemic changes during exercise treadmill testing, regardless of the site of perfusion defects detected by thallium-201 scanning; and monitoring the inferior and lateral leads rarely provides more diagnostic information

  1. The prevalence of the electrocardiographic J wave in the Petit Basset Griffon Vendéen compared to 10 different dog breeds

    DEFF Research Database (Denmark)

    Rudling, E. H.; Schlamowitz, Sarah; Pipper, Christian Bressen

    2016-01-01

    INTRODUCTION: To investigate the prevalence and amplitudes of the electrocardiographic J wave in the Petit Basset Griffon Vendéen compared to 10 other dog breeds. ANIMALS: Electrocardiograms from 206 healthy dogs representing 11 dog breeds were included in the study. Besides Petit Basset Griffon...

  2. Prophylactic accessory-pathway ablation in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern.

    Science.gov (United States)

    Ozenc, S; Iscen, S; Kibrisli, E; Tok, D; Parlak, A; Altinel, O; Altinel, S

    2014-01-01

    The optimal approach is controversial in asymptomatic patients who are coincidentally found to have evidence of an accessory pathway (AP) on an ECG. The risk of sudden cardiac death (SCD) is low, and the risk of developing symptoms also appears to be low, although a wide range of incidences have been reported. In our trial, we tested the hypothesis that if prophylactic accessory-pathway ablation performed at the time of the initial electrophysiological testing would improve the long-term outcome in asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern. Recruitment of patients began on February 1, 2004, and ended on February 5, 2009. All 110 asymptomatic patients were hospitalized and underwent electrophysiological testing the same day to assess the inducibility of atrioventricular reciprocating tachycardia. The anterograde effective refractory period of the accessory pathway was defined as the longest coupling interval at which anterograde block in the bypass tract was observed. For the statistical analysis, the statistical software SPSS version 15.0 for Windows (SPSS Inc., Chicago, IL, USA). Of 110 asymptomatic patients with a Wolff-Parkinson-White electrocardiographic pattern, 80 patients were ablated. Ablation group consisted of these patients. Control group consisted of remaining 30 and were divided into two groups according to the anterograde effective refractory period of the accessory pathway. There was no significant difference between three groups in terms of arrhythmic events (p: 0.58). Asymptomatic patients with the Wolff-Parkinson-White syndrome do not require prophylactic ablation, since they remain asymptomatic for many years.

  3. Characteristics and significance of ischemia detected by ambulatory electrocardiographic monitoring

    International Nuclear Information System (INIS)

    Nabel, E.G.; Rocco, M.B.; Selwyn, A.B.

    1987-01-01

    Ambulatory electrocardiographic (ECG) monitoring of ischemia in patients with coronary artery disease (CAD) provides a new technique for the assessment of ischemic activity and the evaluation of therapies outside of the hospital. Numerous studies have demonstrated that the majority of patients with CAD have episodes of symptomatic and asymptomatic ST segment depression during routine daily activities. Rubidium-82 positron-emission tomographic studies have provided evidence for decreased myocardial perfusion during these episodes of ST segment depression. The prognostic importance of asymptomatic ischemia has been shown in patients with unstable angina to be a marker for early unfavorable cardiac events. Preliminary results suggest a poorer outcome for those patients with chronic stable angina who show episodes of ischemia as well. Ambulatory monitoring studies suggest that total ischemic activity may be underestimated by conventional testing. Whether all ischemic activity detected by ambulatory monitoring requires treatment awaits further study. 69 references

  4. On the feasibility of self-mixing interferometer sensing for detection of the surface electrocardiographic signal using a customized electro-optic phase modulator

    International Nuclear Information System (INIS)

    Bakar, A Ashrif A; Lim, Yah Leng; Wilson, Stephen J; Fuentes, Miguel; Bertling, Karl; Taimre, Thomas; Rakić, Aleksandar D; Bosch, Thierry

    2013-01-01

    Optical sensing offers an attractive option for detection of surface biopotentials in human subjects where electromagnetically noisy environments exist or safety requirements dictate a high degree of galvanic isolation. Such circumstances may be found in modern magnetic resonance imaging systems for example. The low signal amplitude and high source impedance of typical biopotentials have made optical transduction an uncommon sensing approach. We propose a solution consisting of an electro-optic phase modulator as a transducer, coupled to a vertical-cavity surface-emitting laser and the self-mixing signal detected via a photodiode. This configuration is physically evaluated with respect to synthesized surface electrocardiographic (EKG) signals of varying amplitudes and using differing optical feedback regimes. Optically detected EKG signals using strong optical feedback show the feasibility of this approach and indicate directions for optimization of the electro-optic transducer for improved signal-to-noise ratios. This may provide a new means of biopotential detection suited for environments characterized by harsh electromagnetic interference. (paper)

  5. Electrocardiographic Precordial ST‐Segment Deviations and the Risk of Cardiovascular Death

    DEFF Research Database (Denmark)

    Rasmussen, Peter Vibe; Nielsen, Jonas Bille; Pietersen, Adrian

    2014-01-01

    BACKGROUND: We sought to perform a study assessing the association between electrocardiographic ST-segment deviations and cardiovascular death (CVD), in relation to sex and age (≥ and disease. METHODS AND RESULTS: Using...... computerized analysis of ECGs from 285 194 persons, we evaluated the association between precordial ST-segment deviations and the risk of CVD. All data on medication, comorbidity, and outcomes were retrieved from Danish registries. After a median follow-up period of 5.8 years, there were 6679 cardiovascular...... deaths. Increasing ST-depression was associated with an increased risk of CVD in almost all of the precordial leads, with the most robust association seen in lead V5 to V6. ST-elevations in lead V2 to V6 were associated with increased risk of CVD in young women, but not in men. However, ST...

  6. The Diagnostic Agreement of Original and Faxed Copies of Electrocardiograms

    Directory of Open Access Journals (Sweden)

    Sadrihe Hajesmaeel-Gohari

    2013-02-01

    Full Text Available Background: General practitioners working in remote and rural areas sometimes need consultation with cardiologists. One practical and cost-effective way is transmission of patients’ electrocardiographic images via ordinary fax machine to the cardiologists, but there is an important question that how much agreement exists between the diagnoses made by reading an original electrocardiogram and its copy transmitted via fax.Materials and Methods: In this cross-sectional study, 60 original electrocardiographic images were given to cardiologists for diagnosis. In the next step those electrocardiographic images were faxed to the hospital through a simple cheap fax machine, one month later the same cardiologist was asked to put his diagnosis on the copied versions of electrocardiographs, and the results were compared. Results: In 59 studied cases, the two method of diagnoses were exactly the same and only in one case the diagnoses were different. Therefore, Kappa agreement coefficient was calculated as 96%.Conclusion: According to the results of this study, general practitioners working in deprived areas can be certainly recommended to send patients’ electrocardiographic images to the cardiologists via fax in the case of needing consultation.

  7. Prospective comparison of MR imaging (1.5 T) and CT detection of small intracranial metastases

    International Nuclear Information System (INIS)

    Dowd, C.F.; Dillon, W.P.; Laxer, K.; Norman, D.; Newton, T.H.

    1987-01-01

    Prior studies indicate lack of MR imaging sensitivity in the evaluation of intractable seizure patients. The authors reviewed MR imaging studies of 15 patients with intractable seizures. High-quality thin-section multiplanar images were obtained with electrocardiographic gating and/or flow compensation techniques and a 1.5-T General Electric Signa unit. Correlation with intracranial electro-encephalography (EEG), CT, and pathology was obtained in all patients. Abnormalities on MR imaging were detected in all but one patient. Pathology revealed MTS in 12 of 15 patients. Other entities included heterotopias and cavernous angiomas. The authors' study indicates that high-resolution, flow-compensated MR imaging is quite sensitive for localization of eleptogenic structural abnormalities and complements EEG

  8. Relative value of clinical variables, bicycle ergometry, rest radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring at discharge to predict 1 year survival after myocardial infarction

    NARCIS (Netherlands)

    P.M. Fioretti (Paolo); R.W. Brower (Ronald); M.L. Simoons (Maarten); H.J. ten Katen (Harald); A. Beelen (Anita); T. Baardman (Taco); J. Lubsen (Jacob); P.G. Hugenholtz (Paul)

    1986-01-01

    textabstractThe relative value of predischarge clinical variables, bicycle ergometry, radionuclide ventriculography and 24 hour ambulatory electrocardiographic monitoring for predicting survival during the first year in 351 hospital survivors of acute myocardial infarction was assessed. Discriminant

  9. Electrocardiographic, echocardiographic, and indirect blood pressure evaluation in dogs subjected to different sedation protocols

    Directory of Open Access Journals (Sweden)

    Helena Mondardo Cardoso

    Full Text Available ABSTRACT: The present study aimed to evaluate the effects of different sedation protocols on blood pressure and echocardiographic and electrocardiographic parameters in dogs. In total, 24 male mixed-breed dogs with a mean weight of 9.87±3.0kg were used.Animals were randomly divided into four groups (n=6, which were subjected to sedation using the following protocols: acepromazine (0.05mgkg-1 and butorphanol (0.3mgkg-1 (AB; acepromazine (0.05mgkg-1and methadone (0.5mgkg-1 (AM; acepromazine (0.03mgkg-1, methadone (0.5mgkg-1, and midazolam (0.3mgkg-1(MAM; and methadone only (0.5mgkg-1 (M. Indirect blood pressure (BP measurements and computerized electrocardiography (ECG and echocardiography (ECO were performed immediately before the application of the sedation protocol (baseline, and the same evaluations were repeated after 15 minutes. BP decreased in groups AB, MAM, and AM compared to baseline values. Electrocardiographic measurements showed decreased heart rates (HRs after sedation in all groups, and bradycardia was observed after sedation in two dogs from group M and one animal from group AM. The P-wave duration increased after sedation in groups AM and M. After sedation, no changes in cardiac dimensions were revealed byECO.Fractional shortening (FS decreased after sedation in the AM group, and dogs from group AB exhibited a smaller decrease in FS compared with the other groups. The cardiac index (CI was lower in groups AM and M than in the other groups. Animals from group AB were less resistant to examination and exhibited the most favorable sedation scores. It was concluded that the combination of acepromazine and butorphanol was the best sedation protocol for performing echocardiogram measurementsbecause dogs were less resistant to examinations and echocardiographic parameters of FS and CI remained stable.

  10. Ethnic differences in electrocardiographic amplitude measurements

    International Nuclear Information System (INIS)

    Mansi, Ishak A.; Nash, Ira S.

    2004-01-01

    There is a controversy regarding ethnic differences in electrocardiographic (ECG) patterns because of the potentially confounding socioeconomic, nutritional, environmental and occupational factors. We reviewed the first 1000 medical files of a multiethnic community, where all individuals shared similar living conditions. Only healthy adults age 15 to 60 years were included. Wave amplitudes were measured manually from the standard 12lead ECG. Minnesota coding was used. ECG from 597 subjects were included in the study: 350 Saudi Arabians, 95 Indians, 17 Sri-Lankans, 39 Filipinos, and 57 Caucasians; 349 were men. the mean +-SD of Sokolow-Lyon voltage (SLV) in men was signifcantly different among ethnic groups (2.9+-0.86, 2.64+-0.79, 2.73+-0.72, 3.23+-0.61, 2.94+-0.6, 2.58+-0.79 mV, P=0.0006, for Saudi's, Indians, Jordanians, Filipinos, Sri-Lankans, and Caucasians, respectively). SLV was similar among ethnic groups in women. The prevalence of early transition pattern was also different among ethnic groups in men but not women (15.8%, 34.6%, 17.9%, 21.7%, 35.3%, 26.8% in Suadi, Indian, Jordanian, Filipino, Sri-Lankan, and Caucasian, respectively, P=0.037). T wave amplitude was significantly different among ethnic groups in selected lead. ECG wave amplitude differs with ethnic region even when other factors are similar. Using SLV of 3.5 mV as a criterion may overestimate the incidence of left ventricular hypertrophy in some ethnic groups. The pattern of high R wave in lead V1is common in healthy adults in certain ethnic groups. T wave height differs with ethnic origin and sex. (author)

  11. ELECTROCARDIOGRAPHIC CHANGES OBSERVED IN HAEMORRHAGIC AND ISCHAEMIC CEREBROVASCULAR DISEASES

    Directory of Open Access Journals (Sweden)

    Channappa

    2016-03-01

    Full Text Available INTRODUCTION Cardiac abnormalities are relatively common after acute neurologic injury. Disturbances can vary in severity from transient ECG abnormalities to profound myocardial injury and dysfunction. CNS is involved in the generation of cardiac arrhythmias and dysfunction even in an otherwise normal myocardium. AIM To find out proportion of ECG changes observed in ischaemic and haemorrhagic stroke. MATERIALS AND METHODS The Electrocardiographs of 100 patients with acute stroke were studied to find out the types of ECG abnormalities among different types of stroke. RESULTS In our study, the most common ECG abnormalities associated with stroke were prolonged QTc interval, ST-T segment abnormalities, prominent U wave and arrhythmias. Trop-I was positive in 12.8% patients with ECG changes. Statistical significance was found in association with Trop-I positivity and ST depression. CONCLUSION Usually patients with heart disease present with arrhythmias and Ischaemic like ECG changes. But these changes are also seen most often in the patients with presenting with stroke who didn’t have any past history of heart disease. This shows that arrhythmias and ischaemic ECG abnormalities are primarily evolved due to central nervous system disorders.

  12. Electrocardiographic findings in acute cerebrovascular hemorrhage a prospective study of 70 patients

    Directory of Open Access Journals (Sweden)

    Walter Oleschko Arruda

    1992-09-01

    Full Text Available Seventy patients with hemorrhagic stroke were prospectively evaluated regarding the electrocardiographic abnormalities observed within the first 48 hours of the ictus. Group I comprised 55 patients with spontaneous cerebral hemorrhage, and group II 15 patients with subarachnoid hemorrhage. Patients taking cardiac drugs (beta blockers, calcium-channel blockers, inotropic drugs or with severe metabolic/electrolyte disturbances were excluded. The most common ECG abnormality was a prolonged Q-Tc interval: group I, 37 (67.2%; group II, 8 (53.3%. Only 4 (7.2% patients of group I and no patient of group II had a normal ECG. No relation was found between the site of the intracerebral hematoma and the occurrence of any particular ECG change. A prolonged Q-Tc may be related to the development of severe cardiac arrhythmias observed in some patients with acute cerebral hemorrhage.

  13. Coronary imaging techniques with emphasis on CT and MRI

    International Nuclear Information System (INIS)

    Lederlin, Mathieu; Latrabe, Valerie; Corneloup, Olivier; Cochet, Hubert; Montaudon, Michel; Laurent, Francois; Thambo, Jean-Benoit

    2011-01-01

    Coronary artery imaging in children is challenging, with high demands both on temporal and spatial resolution due to high heart rates and smaller anatomy. Although invasive conventional coronary angiography remains the benchmark technique, over the past 10 years, CT and MRI have emerged in the field of coronary imaging. The choice of hardware is important. For CT, the minimum requirement is a 64-channel scanner. The temporal resolution of the scanner is most important for optimising image quality and minimising radiation dose. Manufacturers have developed several modes of electrocardiographic (ECG) triggering to facilitate dose reduction. Recent technical advances have opened new possibilities in MRI coronary imaging. As a non-ionising radiation technique, MRI is of great interest in paediatric imaging. It is currently recommended in centres with appropriate expertise for the screening of patients with suspected congenital coronary anomalies. However, MRI is still not feasible in infants. This review describes and discusses the technical requirements and the pros and cons of all three techniques. (orig.)

  14. Evaluation of congenital heart disease by three-dimensional MR imaging

    International Nuclear Information System (INIS)

    Vannier, M.W.; Gutierrez, F.R.; Canter, C.E.; Yoffie, R.L.; Hildebolt, C.F.

    1988-01-01

    In an evaluation of the detectability of intra-and extracardiac morphologic defects with electrocardiographically gated magnetic resonance (MR) imaging, 100 patients were studied, including ten without and 90 with abnormalities. The abnormalities included septal defects, tetrology of Fallot, pulmonary atresia, transposition of the great vessels, and others. The patients with abnormalities were studied angiographically and with echocardiographic analyses. Two radiologists with cardiac MR imaging experience evaluated the scans in a blinded fashion, and the results were analyzed by means of receiver operating characteristic analysis. The diagnostic value of routine two-dimensional cardiac MR imaging was compared with that of three-dimensional reconstruction imaging and with the results of cardiac catheterization and echocardiography. The reported sensitivity and specificity of echocardiography in the detection of congenital heart disease is comparable to that of MR imaging. The differences in diagnostic value between various modalities for the imaging of congenital heart disease may be determined from the results of the preliminary series

  15. Technetium-99m-pyrophosphate myocardial imaging in unstable angina

    International Nuclear Information System (INIS)

    Willerson, J.T.; Parkey, R.W.; Lewis, S.E.; Buja, L.M.; Bonte, F.J.

    1980-01-01

    The authors have found that approximately one third of patients with the syndrome of unstable angina pectoris have abnormal 99mTc-pyrophosphate myocardial scintigrams even in the absence of abnormal enzymes and electrocardiographic confirmation of the presence of acute myocardial necrosis. Thus, 99mTc-pyrophosphate myocardial imaging technique appears to represent a sensitive means to detect acute multicellular injury associated with the clinical syndrome of unstable angina pectoris even when cardiac enzymes are normal and the electrocardiogram does not definitively document the presence of acute myocardial necrosis. (Auth.)

  16. Clinical characteristics in patients showing ischemic electrocardiographic changes during adenosine triphosphate loading single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Ohtaki, Yuka; Chikamori, Taishiro; Hida, Satoshi; Tanaka, Hirokazu; Igarashi, Yuko; Hatano, Tsuguhisa; Usui, Yasuhiro; Miyagi, Manabu; Yamashina, Akira

    2010-01-01

    Although ischemic electrocardiographic (ECG) changes during dipyridamole or adenosine infusion have been reported as a marker for severe coronary artery disease (CAD), few studies have focused on ST-segment changes with adenosine triphosphate (ATP)-loading myocardial single-photon emission computed tomography (SPECT). Between January 2003 and August 2008, 4650 consecutive patients underwent ATP-loading SPECT. After 1412 patients with left bundle branch block, pacemaker rhythm, or previous coronary revascularization were excluded, 16 out of 3238 patients (0.5%) showed ischemic ST-segment depression during ATP-loading myocardial SPECT. They were aged 67±11 years; 10 were men and 6 women. Of these patients, 8 demonstrated perfusion abnormalities, whereas the remaining 8 showed normal myocardial perfusion imaging. In 6 of the 8 patients with abnormal SPECT, coronary angiography was performed, revealing left main trunk disease in 1 patient, 3-vessel disease in 4, 1-vessel disease with proximal left ascending artery occlusion in 1, and an insignificant lesion in 1. By contrast, no major cardiac event was observed in the 8 patients with normal SPECT during follow-up for an average of 2 years. The prevalence of ischemic ST-segment changes during ATP loading is very rare. However, this finding should be taken into account since almost half of the patients, particularly those with perfusion abnormalities, may have severe CAD which requires coronary revascularization. (author)

  17. ST-segment deviation during 24-hour ambulatory electrocardiographic monitoring and exercise stress test in healthy male subjects 51 to 75 years of age: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner; Sørum, C

    1999-01-01

    or descending ST-segment depression of >/=0.15 mV during Holter monitoring or at the exercise test, respectively. Furthermore, the specificity was 0.95 when a horizontal or downsloping ST-segment depression of 0.1 mV was displayed in both the Holter and exercise electrocardiographic recording system......BACKGROUND: Although ST-segment deviation has been evaluated and used during many years both on continuous electrocardiographic Holter monitoring and during exercise stress testing, considerable controversy still remains concerning the prevalence and diagnostic significance of fortuitously...... discovered ST-segment deviation in asymptomatic healthy persons. METHODS AND RESULTS: The occurrence of ST-segment deviation was studied in a population of 63 clinically healthy male subjects 51 to 75 years of age, with the use of 24-hour Holter monitoring and exercise stress testing. The subjects were...

  18. Assessment of ischemic heart disease by dipyridamole stress electrocardiographic gated myocardial single photon emission computed tomography with technetium-99m tetrofosmin

    International Nuclear Information System (INIS)

    Kanna, Masahiko; Mitani, Isao; Nakamaru, Masashi; Shibuya, Ken; Takeda, Kazuyoshi; Asahina, Shigeru; Kitamura, Yutaka; Higuma, Kikuhiko; Ishii, Masao

    1998-01-01

    Simultaneous assessment of stress perfusion and rest function is possible with gated single photon emission computed tomography (SPECT) using stress injected technetium-99m ( 99m Tc) tetrofosmin (TF). The feasibility of dipyridamole stress electrocardiographic gated myocardial SPECT (GSPECT) with TF was examined as an alternative to conventional stress/rest imaging. Fifty-one patients underwent stress GSPECT. 740 MBq of TF was administered 3 min after dipyridamole infusion. GSPECT acquisition was performed one hour after the injection. Additional rest SPECT was performed on another day only in patients with abnormal perfusion on stress images. Perfusion and thickening were analyzed visually on 17 segments of the left ventricle. Percentage of wall thickening (%WT) was also calculated in 17 segments of the polar map. Thirty-two of 51 patients (63%) had normal stress perfusion and normal rest thickening. Nineteen of 51 patients (37%) had abnormal perfusion on stress images. Among 157 abnormal perfusion segments of the 19 patients, 139 segments (89%) had thickening and the rest (11%) had no thickening. %WT was higher in the reversible segments with or without thickening. There was better agreement for the identification of normal segments and the presence of reversibility between stress GSPECT and the conventional stress/rest study in patients without previous myocardial infarction than in those with previous myocardial infarction (89% vs 79%). These results suggest that stress GSPECT may substitute for conventional stress/rest perfusion study in patients without previous myocardial infarction, allowing shorter examination time and lower cost. However, stress GSPECT does not replace the need for rest perfusion study in patients with previous myocardial infarction, because of underestimation of viability, but %WT may eliminate this underestimation. (author)

  19. Dual Atrioventricular Nodal Pathways Physiology: A Review of Relevant Anatomy, Electrophysiology, and Electrocardiographic Manifestations

    Directory of Open Access Journals (Sweden)

    Bhalaghuru Chokkalingam Mani, MD

    2014-01-01

    Full Text Available More than half a century has passed since the concept of dual atrioventricular (AV nodal pathways physiology was conceived. Dual AV nodal pathways have been shown to be responsible for many clinical arrhythmia syndromes, most notably AV nodal reentrant tachycardia. Although there has been a considerable amount of research on this topic, the subject of dual AV nodal pathways physiology remains heavily debated and discussed. Despite advances in understanding arrhythmia mechanisms and the widespread use of invasive electrophysiologic studies, there is still disagreement on the anatomy and physiology of the AV node that is the basis of discontinuous antegrade AV conduction. The purpose of this paper is to review the concept of dual AV nodal pathways physiology and its varied electrocardiographic manifestations.

  20. Arrhythmogenic right ventricular cardiomyopathy: contribution of different electrocardiographic techniques.

    Science.gov (United States)

    Moreira, Davide; Delgado, Anne; Marmelo, Bruno; Correia, Emanuel; Gama, Pedro; Pipa, João; Nunes, Luís; Santos, Oliveira

    2014-04-01

    Arrhythmogenic right ventricular cardiomyopathy, also known as arrhythmogenic right ventricular dysplasia, is a condition in which myocardium is replaced by fibrous or fibrofatty tissue, predominantly in the right ventricle. It is clinically characterized by potentially lethal ventricular arrhythmias, and is a leading cause of sudden cardiac death. Its prevalence is not known exactly but is estimated at approximately 1:5000 in the adult population. Diagnosis can be on the basis of structural and functional alterations of the right ventricle, electrocardiographic abnormalities (including depolarization and repolarization alterations and ventricular arrhythmias) and family history. Diagnostic criteria facilitate the recognition and interpretation of non-specific clinical features of this disease. The authors present a case in which the diagnosis of arrhythmogenic right ventricular cardiomyopathy was prompted by the suspicion of right ventricular disease on transthoracic echocardiography. This was confirmed by detection of epsilon waves on analysis of the ECG, which generally go unnoticed but in this case were the key to the diagnosis. Their presence was also shown by non-conventional ECG techniques such as modified Fontaine ECG. The course of the disease culminated in the occurrence of ventricular tachycardia, which prompted placement of an implantable cardioverter-defibrillator. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  1. Effect of pregnancy and correlation of weight and heart rate with electrocardiographic parameters in the American Miniature Horse

    Directory of Open Access Journals (Sweden)

    B.P. Santarosa

    2016-06-01

    Full Text Available ABSTRACT There are studies on electrocardiogram (ECG in several breeds of horses, which highlights the growing importance of cardiology in this species. But few authors have addressed the influence of pregnancy on the cardiac physiology of the mare, and specifically, there are no studies on the Mini-horse breed, as well as no correlation of body weight (BW and heart rate (HR with electrocardiographic parameters in this breed. The aims of this study were to determine the effects of pregnancy on ECG parameters and to examine the relationships between these variables and body weight (BW and heart rate (HR. A total of 203 animals were used, including 143 females (66 pregnant and 60 males. Electrocardiographic examinations were performed by computerized electrocardiogram (TEB, and the parameters were evaluated in six leads in the frontal plane (Lead I, II, III, aVR, aVL and aVF and base-apex (BA. BW was inversely proportional to HR, which in turn showed an inverse relationship with the duration of the P-wave and the PR and QT intervals. The P-wave amplitude (lead II was higher in pregnant animals than in non-pregnant animals. The effect of reproductive status should be monitored by ECG throughout the entire gestational period. The 66 pregnant mares in this study were examined during the first third of their pregnancies, thus, few differences were observed between pregnant and non-pregnant animals.

  2. Triangulation of the monophasic action potential causes flattening of the electrocardiographic T-wave

    DEFF Research Database (Denmark)

    Bhuiyan, Tanveer Ahmed; Graff, Claus; Thomsen, Morten Bækgaard

    2012-01-01

    of the action potential under the effect of the IKr blocker sertindole and associated these changes to concurrent changes in the morphology of electrocardiographic T-waves in dogs. We show that, under the effect of sertindole, the peak changes in the morphology of action potentials occur at time points similar......It has been proposed that triangulation on the cardiac action potential manifests as a broadened, more flat and notched T-wave on the ECG but to what extent such morphology characteristics are indicative of triangulation is more unclear. In this paper, we have analyzed the morphological changes...... to those observed for the peak changes in T-wave morphology on the ECG. We further show that the association between action potential shape and ECG shape is dose-dependent and most prominent at the time corresponding to phase 3 of the action potential....

  3. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  4. Electrocardiographic intricacies clarified by echocardiography--should the electrocardiogram be interpreted echocardiographically?

    Science.gov (United States)

    Ker, James

    2012-07-12

    During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Electrocardiographic exam in female spotted pacas (Cuniculus paca

    Directory of Open Access Journals (Sweden)

    Ricardo A.R. Uscategui

    2016-06-01

    Full Text Available Abstract: Considering the limited physiological information available on neotropical rodents and the importance of this information for pathophysiological and conservation studies of these species, the aim of this study was to evaluate the cardiac electric physiology of healthy captivity spotted pacas (Cuniculus paca under chemical restraint, due to wild nature of these animals. Eleven adult female pacas were evaluated by blood count and biochemical dosage to rule out any associate disease. Each animal was evaluated in three periods every 15 days. After chemical restraint with intramuscular midazolam 0.5mg/kg and ketamine 25mg/kg, animals were subjected to a computerized electrocardiogram, where bipolar (DI, DII and DIII and augmented unipolar leads (aVR, aVL, aVF were obtained. Descriptive statistics were calculated for each parameter and built the confidence interval (CI at significance level of 95%. The electrocardiographic examination was performed without difficult. ECG tracing in DII represents a QRS complex with positive polarity, preceded by a P wave of the same polarity and proceeded by T wave of variable polarity. Heart rate mean was 150±17 bpm, and cardiac electrical axis 33.4±21.9°. All animals showed sinusal rhythm. The ECG recording technique associated with chemical restraint was well tolerated, allowing quick acquisition of reliable ECG tracings with high repeatability, which produced sufficient results to determine the heart rhythm and suggest measures of ECG complexes duration and amplitude.

  6. Electrocardiographic findings in patients with polycythemia vera.

    Science.gov (United States)

    Kayrak, Mehmet; Acar, Kadir; Gul, Enes Elvin; Abdulhalikov, Turyan; Bağlıcaklıoğlu, Murat; Sonmez, Osman; Kaya, Zeynettin; Arı, Hatem

    2012-01-01

    The 12-lead surface electrocardiogram (ECG) is a useful tool to predict both atrial and ventricular arrhythmias via P-wave and QT measurements and its derivatives. Polycythemia vera (PV) is a chronic myeloproliferative disorder associated with cardiovascular events. The aim of this study was to assess ECG findings of patients with PV. Sixty patients with PV (34 male, mean age 58±11 years) and 60 age and gender-matched healthy volunteers were enrolled into the study. From the 12-lead surface ECG, P-wave and both conventional QT measurements and transmyocardial repolarization parameters (T(peak)-T(end) interval (T(p)-T(e)) and derivatives) were evaluated digitally by two experienced cardiologists. In addition, a novel parameter, Pi was calculated digitally as the standard deviation of the P-wave duration across the 12 ECG leads. QT duration and corrected QT interval were significantly longer in the PV group compared to healthy controls (pe) was longer and the T(p)-T(e)/QT ratio was significantly higher in the PV group compared to the controls. P-wave analyses showed that all P-wave parameters including Pmax, Pmin, P dispersion, and Pi were significantly prolonged in PV patients compared to the controls. The increase of both T(p)-T(e )and P max in the PV group was independent of age, BMI, diabetes and hypertension, gender, systolic blood pressure, hemoglobin, hematocrit, left atrial dimension, left ventricular end-diastolic diameter and early deceleration time in a univariate analysis of co-variance model (F=11.097, p=0.001 and F=31.537, p=0.0001, respectively). The present study demonstrated that PV may be associated with electrocardiographic abnormalities of both atrium and ventricle.

  7. Triple vessel coronary artery disease presenting as a markedly positive stress electrocardiographic test and a negative SPECT-TL scintigram: a case of balanced Ischemia

    Directory of Open Access Journals (Sweden)

    Eyal Herzog

    2011-09-01

    Full Text Available The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. We present a case of an 81- year old post-menopausal female who presented to her primary care physician for evaluation of a 6-week dyspnea on exertion and was referred to our institution for exercise stress test with Thallium SPECT with the objective of ruling out coronary artery disease and identifying possible areas of myocardial ischemia. The resting electrocardiogram was unremarkable and stress test evaluation was made. The patient was admitted to the cardiac care unit and coronary artery bypass grafting was successfully performed. The presence of false negative nuclear stress test in the settings of positive electrocardiographic changes is a very unusual phenomenon and is usually secondary to balanced ischemia of the myocardial segments evaluated by SPECT-TL. Patients undergoing stress tests with these characteristics should undergo careful evaluation and a high level of suspicion should be adopted for further diagnostic assessment of coronary artery disease.

  8. Dynamic studies of cardiac valvular disease using a new fast multiphase MR imaging technique

    International Nuclear Information System (INIS)

    Pettigrew, R.; Churchwell, A.; Parks, W.J.; Dannels, W.; Smith, H. III; Baron, M.G.

    1986-01-01

    To determine the potential utility of fast multiphase (FM) imaging for the assessment of cardiac valvular disease, ten healthy volunteers and 18 patients were studied. The FM technique employed gradient echoes with TE -- 15 msec and small exitation angles with TR -- 50 msec. Cine display of the electrocardiographically gated FM images allowed clear visualization of regurgitant blood flow in each of 15 patients with tricuspid or mitral insufficiency. Magnetic field distortions in two patients with Bjork-Shiley aortic prostheses and regurgitation prevented definitive visualization of the flow patterns. An equivocal flow pattern was seen in one case of mitral stenosis. Thus, FM imaging may have significant utility as an adjunctive procedure for the assessment of atrioventricular valve insufficiently, without requiring a contrast agent. Difficulties may exist with some prosthetic valves

  9. Epilepsy-induced electrocardiographic alterations following cardiac ischemia and reperfusion in rats

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, J.G.P. [Departamento de Farmacologia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Universidade Iguaçu, Campos V, Itaperuna, RJ (Brazil); Faculdade de Minas, Muriaé, MG (Brazil); Vasques, E.R. [Departamento de Gastroenterologia, LIM 37, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP (Brazil); Arida, R.M. [Departamento de Fisiologia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Cavalheiro, E.A. [Departamento de Neurologia e Neurocirurgia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Cabral, F.R.; Torres, L.B. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Menezes-Rodrigues, F.S.; Jurkiewicz, A.; Caricati-Neto, A. [Departamento de Farmacologia, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Godoy, C.M.G. [Departamento de Ciência e Tecnologia, Universidade Federal de São Paulo, São José dos Campos, SP (Brazil); Gomes da Silva, S. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Núcleo de Pesquisas Tecnológicas, Programa Integrado em Engenharia Biomédica, Universidade de Mogi das Cruzes, Mogi das Cruzes, SP (Brazil)

    2015-01-13

    The present study evaluated electrocardiographic alterations in rats with epilepsy submitted to an acute myocardial infarction (AMI) model induced by cardiac ischemia and reperfusion. Rats were randomly divided into two groups: control (n=12) and epilepsy (n=14). It was found that rats with epilepsy presented a significant reduction in atrioventricular block incidence following the ischemia and reperfusion procedure. In addition, significant alterations were observed in electrocardiogram intervals during the stabilization, ischemia, and reperfusion periods of rats with epilepsy compared to control rats. It was noted that rats with epilepsy presented a significant increase in the QRS interval during the stabilization period in relation to control rats (P<0.01). During the ischemia period, there was an increase in the QRS interval (P<0.05) and a reduction in the P wave and QT intervals (P<0.05 for both) in rats with epilepsy compared to control rats. During the reperfusion period, a significant reduction in the QT interval (P<0.01) was verified in the epilepsy group in relation to the control group. Our results indicate that rats submitted to an epilepsy model induced by pilocarpine presented electrical conductivity alterations of cardiac tissue, mainly during an AMI episode.

  10. Epilepsy-induced electrocardiographic alterations following cardiac ischemia and reperfusion in rats

    International Nuclear Information System (INIS)

    Tavares, J.G.P.; Vasques, E.R.; Arida, R.M.; Cavalheiro, E.A.; Cabral, F.R.; Torres, L.B.; Menezes-Rodrigues, F.S.; Jurkiewicz, A.; Caricati-Neto, A.; Godoy, C.M.G.; Gomes da Silva, S.

    2015-01-01

    The present study evaluated electrocardiographic alterations in rats with epilepsy submitted to an acute myocardial infarction (AMI) model induced by cardiac ischemia and reperfusion. Rats were randomly divided into two groups: control (n=12) and epilepsy (n=14). It was found that rats with epilepsy presented a significant reduction in atrioventricular block incidence following the ischemia and reperfusion procedure. In addition, significant alterations were observed in electrocardiogram intervals during the stabilization, ischemia, and reperfusion periods of rats with epilepsy compared to control rats. It was noted that rats with epilepsy presented a significant increase in the QRS interval during the stabilization period in relation to control rats (P<0.01). During the ischemia period, there was an increase in the QRS interval (P<0.05) and a reduction in the P wave and QT intervals (P<0.05 for both) in rats with epilepsy compared to control rats. During the reperfusion period, a significant reduction in the QT interval (P<0.01) was verified in the epilepsy group in relation to the control group. Our results indicate that rats submitted to an epilepsy model induced by pilocarpine presented electrical conductivity alterations of cardiac tissue, mainly during an AMI episode

  11. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  12. The stability of myocardial area at risk estimated electrocardiographically in patients with ST elevation myocardial infarction

    DEFF Research Database (Denmark)

    Carlsen, Esben A; Hassell, Mariëlla E C J; van Hellemond, Irene E G

    2014-01-01

    In patients with ST-elevation myocardial infarction (STEMI) the amount of myocardial area at risk (MaR) indicates the maximal potential loss of myocardium if the coronary artery remains occluded. During the time course of infarct evolution ischemic MaR is replaced by necrosis, which results...... in a decrease in ST segment elevation and QRS complex distortion. Recently it has been shown that combining the electrocardiographic (ECG) Aldrich ST and Selvester QRS scores result in a more accurate estimate of MaR than using either method alone. Therefore, we hypothesized that the combined Aldrich...... reperfusion (ECG2). The combined Aldrich and Selvester score was considered stable if the difference between ECG1 and ECG2 was ST elevation in 4...

  13. Electrocardiographic changes in the most frequent endocrine disorders associated with cardiovascular diseases. Review of the literature.

    Science.gov (United States)

    Costache, Irina Iuliana; Ungureanu, Maria Christina; Iliescu, D; Petriş, A; Botnariu, Gina

    2015-01-01

    Car- diovascular abnormalities associated with endocrine diseases are often frequent and due to complex relationships between endocrine glands (with internal secretion) and cardiovascular system (heart and vessels). Certain hormones secreted by the endocrine glands (particularly the thyroid and pituitary gland) excesses or deficiencies, are involved in morphogenesis, growth processes and activity regulation of cardiovascular system, most often in connection with the autonomic nervous system. There are also a lot of electrocardiographic changes caused by hormonal disorders that requires differential diagnosis and represents the source of erroneous diagnosis. Endocrine pathology occurred later than a heart disease, may worse heart function. Ignoring the cardiovascular events that may occur in the evolution of endo- crine diseases, may induce increased mortality due to cardiovascular complications.

  14. Atrial and Ventricular Electrocardiographic Dromotropic Disturbances in Down Syndrome Patients with Structurally Normal Heart: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Yazdan Ghandi

    2018-03-01

    Full Text Available Background: We designed a cross-sectional study to determine electrocardiographic disorders in Down syndrome patients with congenitally normal hearts in a bid to predict fatal cardiac arrhythmia in the future. Materials and Methods: We investigated 60 children with DS without congenital abnormal hearts. Sixty healthy juveniles were also included in the study as a control group. Physical examination, electrocardiography, and echocardiography were performed in all subjects. Corrected QT interval (QTc was measured according to Bazett’s formula. Results: Patients with DS consisted of 32 males (53.33%, and 28 females (46.66%, aged 6–13 (9.21 ± 6.24 years old. Healthy subjects comprised 31 males (51.66%, and 29 females (48.33% with a mean age of 9.15 ± 5.01. The two groups were significantly different in terms of heart rate (P=0.006, maximum P-wave duration (P=0.001, and P-wave dispersion (PWd, P=0.0001. There was no statistically significant difference regarding minimum P-wave duration (P=0.176. The patients with DS had a greater maximum QTc interval, QT dispersion, and corrected QT interval dispersion (QTc-d than the healthy control subjects (P=0.001. However, there was no difference in maximum QT interval and minimum QTc interval between the two groups (P=0.67 and P=0.553, respectively. A positive correlation was found between age, heart rate, and all electrocardiographic variables. Conclusion: All DS patients, even in the absence of concomitant congenital heart disease should be followed up carefully by electrocardiography, looking for increased PWd and QTc-d to detect predisposed cases to arrhythmia.

  15. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  16. Model-based imaging of cardiac electrical function in human atria

    Science.gov (United States)

    Modre, Robert; Tilg, Bernhard; Fischer, Gerald; Hanser, Friedrich; Messnarz, Bernd; Schocke, Michael F. H.; Kremser, Christian; Hintringer, Florian; Roithinger, Franz

    2003-05-01

    Noninvasive imaging of electrical function in the human atria is attained by the combination of data from electrocardiographic (ECG) mapping and magnetic resonance imaging (MRI). An anatomical computer model of the individual patient is the basis for our computer-aided diagnosis of cardiac arrhythmias. Three patients suffering from Wolff-Parkinson-White syndrome, from paroxymal atrial fibrillation, and from atrial flutter underwent an electrophysiological study. After successful treatment of the cardiac arrhythmia with invasive catheter technique, pacing protocols with stimuli at several anatomical sites (coronary sinus, left and right pulmonary vein, posterior site of the right atrium, right atrial appendage) were performed. Reconstructed activation time (AT) maps were validated with catheter-based electroanatomical data, with invasively determined pacing sites, and with pacing at anatomical markers. The individual complex anatomical model of the atria of each patient in combination with a high-quality mesh optimization enables accurate AT imaging, resulting in a localization error for the estimated pacing sites within 1 cm. Our findings may have implications for imaging of atrial activity in patients with focal arrhythmias.

  17. Clinical and electrocardiographic evaluation during experimental toad poisoning in dogs

    Directory of Open Access Journals (Sweden)

    AC Camplesi

    2010-01-01

    Full Text Available Accidents involving toad poisoning are frequent and dogs are the most common victims; they become poisoned by biting or ingesting a toad. When released in the organism, the venom is absorbed by both the oral mucosa and the digestive tract, initiating its toxic action. The aim of this work was to evaluate the clinical and electrocardiographic aspects of dogs subjected to experimental toad poisoning, as well as their response to treatment with propranolol. Twenty dogs were divided into two groups, a control group (n = 5 and a poisoned group (n = 15. After general anesthesia, the control group received a placebo, while the poisoned group received a venom aliquot through an orogastric tube. Results were tested through multivariate analysis (p < 0.05. The animals in the poisoned group had gastrointestinal symptoms including emesis, intense salivation, hyperemic or congested oral mucosa and pasty diarrhea. Non-responsive mydriasis, nystagmus, depression, stupor, tachypnea, opisthotonus and ataxia were also manifested by 100% of the poisoned animals. Affected dogs had an increase in blood pressure, statistically significant throughout study. Five poisoned animals developed ventricular tachycardia and were treated with propranolol (0.5 mg/kg IV. All propranolol-treated animals returned to normal sinus rhythm, which evidences the efficacy of this drug to treat ventricular arrhythmias caused by toad venom.

  18. Postoperative evaluation of surgical procedures in congenital heart disease with MR imaging

    International Nuclear Information System (INIS)

    Seelos, K.C.; Kersting-Sommerhoff, B.; Higgins, C.B.

    1989-01-01

    This paper reports on a study in which electrocardiographically gated spin-echo MR imaging was used to evaluate 23 patients with congenital heart disease who had undergone Waterston (n = 3), Potts (n = 2), Senning (n = 3), Fontan (n = 3), Rastelli (n = 4), Damus (n = 1) and Jatene (n = 7) procedures. Surgical shunts, conduits, or baffles were identified correctly in all patients. Patency, atresia and hypoplasia of central pulmonary arteries (PAs) as well as postoperative complications (focal stenosis of PAs, thrombosed pseudoaneurysm, intramural abscess) were diagnosed. MR findings were corroborated with angiography, echocardiography, and surgery. Narrowing of the right ventricular outflow tract and focal compression of the proximal PAs were recognized as specific complications of the Jatene procedure. MR imaging appears to be effective for the postoperative evaluation of surgical procedures used for congenital heart disease

  19. Electrocardiographic and Blood Pressure Alterations During Electroconvulsive Therapy in Young Adults

    Directory of Open Access Journals (Sweden)

    Rumi Demetrio Ortega

    2002-01-01

    Full Text Available OBJECTIVE - To study cardiovascular alterations in young patients with no apparent organic disease who underwent electroconvulsive therapy. METHODS - The study comprised 47 healthy patients (22 males and 25 females with a mean age of 30.3 years, who underwent electroconvulsive therapy. Ambulatory blood pressure monitoring and continuous electrocardiographic monitoring (Holter monitor were performed during 24 hours. Blood pressure and heart rate were assessed 4 hours prior to electric shock administration, during electric shock administration, and 3 hours after electric shock administration. Arrhythmias and alterations in the ST segment in 24 hours were recorded. RESULTS - On electroconvulsive therapy, a significant increase in blood pressure and heart rate was observed and the measurements returned to basal values after 25 minutes. Three females had tracings with depression of the ST segment suggesting myocardial ischemia prior to and after electroconvulsive therapy. Coronary angiography was normal. No severe cardiac arrhythmias were diagnosed. CONCLUSION - 1 Electroconvulsive therapy is a safe therapeutic modality in psychiatry; 2 it causes a significant increase in blood pressure and heart rate; 3 it may be associated with myocardial ischemia in the absence of coronary obstructive disease; 4 electroconvulsive therapy was not associated with the occurrence of severe cardiac arrhythmias.

  20. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    International Nuclear Information System (INIS)

    Braceli, Agustín Iriart; Morani, Jorge Exequiel

    2011-01-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  1. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    Science.gov (United States)

    Iriart Braceli, Agustín; Exequiel Morani, Jorge

    2011-12-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  2. Propiedades psicométricas de los índices de Conners-3 y Conners Early Childhood en población escolar española

    Directory of Open Access Journals (Sweden)

    Paula Morales-Hidalgo

    2017-01-01

    Full Text Available Antecedentes/Objetivo: Analizar las propiedades psicométricas del Conners 3 ADHD Index (Conners 3 AI y del Conners Early Children Global Index (Conners ECGI, en sus formas para padres (PF y maestros (TF, en escolares españoles. Método: Estudio transversal en doble fase. En la primera fase, se recogió información de maestros (n=1.796 y padres (n=882 de niños de 4-5 y 10-11 años. En la segunda fase (n=196, se evaluaron individualmente niños a riesgo de TDAH y controles. Resultados: Se confirmó la estructura bifactorial del Conners 3 AI, que agrupa síntomas de hiperactividad-impulsividad e inatención, y del Conners ECGI PF, que agrupa síntomas labilidad emocional e inquietudimpulsividad. A diferencia de la versión original, el Conners ECGI TF presentó un factor adicional de inatención. La evidencia de validez convergente con el Child Behavior Checklist y la Kiddie-Schedule for Affective Disorders y Schizophrenia, y de validez con criterios externos (rendimiento académico fueron entre moderadas y altas. Se encontraron puntuaciones significativamente más altas en los niños que en las niñas para ambos índices. Las puntuaciones directas correspondientes a puntuaciones T clínicas fueron más elevadas que en la versión original. Conclusiones: Los índices de Conners pueden considerarse instrumentos válidos y fiables para detectar sintomatología de TDAH en población española. © 2017 Asociación Española de Psicología Conductual. Published by Elsevier España, S.L.U. This is an open access article under the CC BY−NC−ND license (http://creativecommons. org/licenses/by−nc−nd/4.0/.

  3. Effects of parenteral administration of enrofloxacin on electrocardiographic parameters in hospitalized dogs

    Directory of Open Access Journals (Sweden)

    Carlos Fernando Agudelo Ramírez

    2012-01-01

    Full Text Available The effect of enrofloxacin on the QT interval of the electrocardiogram was studied in 30 hospitalized dogs. The experimental group (n = 15 received enrofloxacin parenterally (subcutaneously at a dose of 5 mg/kg twice daily and amoxicillin-clavulanate intravenously at a dose of 22 mg/kg three times daily. The control group (n = 15 received only amoxicillin-clavulanate. Electrocardiography was carried out for 5 min once daily for 6 days. The QT interval was corrected by four different formulae. No differences were found between the two groups or within each group for the duration of the study. On the last day of the study the average QT interval for the control and experimental groups was 213.2 ms and 202.9 ms, respectively. Enrofloxacin did not cause prolongation of the QT or corrected QT intervals. We can conclude that the parenteral administration of enrofloxacin in non-cardiac dogs does not adversely affect the electrocardiographic indicators (no prolongation of the QT or corrected QT interval and does not induce ventricular arrhythmias. Parenteral use of enrofloxacin is thus safe and effective in non-cardiac dogs.

  4. Changes in electrocardiographic findings after closed thoracostomy in patients with spontaneous pneumothorax

    Science.gov (United States)

    Lee, Wonjae; Lee, Yoonje; Kim, Changsun; Choi, Hyuk Joong; Kang, Bossng; Lim, Tae Ho; Oh, Jaehoon; Kang, Hyunggoo; Shin, Junghun

    2017-01-01

    Objective We aimed to describe electrocardiographic (ECG) findings in spontaneous pneumothorax patients before and after closed thoracostomy. Methods This is a retrospective study which included patients with spontaneous pneumothorax who presented to an emergency department of a tertiary urban hospital from February 2005 to March 2015. The primary outcome was a difference in ECG findings between before and after closed thoracostomy. We specifically investigated the following ECG elements: PR, QRS, QTc, axis, ST segments, and R waves in each lead. The secondary outcomes were change in ST segment in any lead and change in axis after closed thoracostomy. Results There were two ECG elements which showed statistically significant difference after thoracostomy. With right pneumothorax volume of greater than 80%, QTc and the R waves in aVF and V5 significantly changed after thoracostomy. With left pneumothorax volume between 31% and 80%, the ST segment in V2 and the R wave in V1 significantly changed after thoracostomy. However, majority of ECG elements did not show statistically significant alteration after thoracostomy. Conclusion We found only minor changes in ECG after closed thoracostomy in spontaneous pneumothorax patients. PMID:28435901

  5. Electrocardiographic characteristics of atrioventricular block induced by tilt testing.

    Science.gov (United States)

    Zyśko, Dorota; Gajek, Jacek; Koźluk, Edward; Mazurek, Walentyna

    2009-02-01

    The electrocardiographic (ECG) characteristics of atrioventricular (AV) block during reflex syncope may be unique due to the presence of hypervagotonia. The aim of the present study was to define the ECG characteristics of the AV block induced by neurocardiogenic reflex provoked by tilt testing (TT). A series of 31 patients with presumed vasovagal syncope and AV block provoked by TT was studied. The duration of PP and PR interval, AV block grade and type, concomitant arrhythmias, and timing of the AV block occurrence were assessed. The AV block occurred at TT termination in 26 patients, in the recovery in 4 patients, and in both periods in 1 patient. Atrioventricular block was preceded by sinus slowing, and sinus rhythm during AV block was slow and instable. Mobitz I, 2:1 second-degree AV block, and advanced second-degree AV block were recognized in 35.5, 48.4, and 67.8% of patients, respectively. Third-degree AV block was diagnosed in 41.9% of patients. Twenty-one patients had at least two AV block forms. The most prevalent concomitant arrhythmia was junctional escape rhythm (61.3%). (i) The occurrence of the AV block during neurocardiogenic reaction induced by TT is always preceded by sinus rhythm slowing and usually by PR interval prolongation. (ii) The AV block provoked by TT usually occurs at TT termination, but may occur even in the recovery period in a supine position. Sometimes the AV block may be present both at TT termination and during the recovery period.

  6. Research on comparison of exposure with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode in coronary multi-slice spiral CT angiography

    International Nuclear Information System (INIS)

    Liu Bin; Guo Senlin; Wei Lan; Fei Xiaolu; Bai Mei

    2009-01-01

    Objective: The objective of this article was to compare patients dose with electrocardiographic gated mA modulation (ECG) and ECG and CAREDose 4D mode during coronary MSCT angiography. Methods: The research was based on phantom experiment and computer simulation to get the mean value of peak skin dose data and effective dose data respectively and to analyze deterministic and stochastic radiation risk. Results: The peak skin dose using ECG mode alone and using ECG and CAREDose 4D mode with the same image noise level was (87.4 ± 0.9) and (45.9 ± 1.2) mGy respectively. Effective dose was 17 and 10 rosy for ECG mode and ECG and CAREDose 4D mode respectively. Comparing with ECG mode alone, ECG and CAREDose 4D mode reduced organ dose of gonad, red marrow, lung, stomach, breast and thyroid by 40.0%, 36.7%, 39.3%, 37.7%, 38.8% and 38.9%, respectively. Conclusion: Results showed that ECG and CAREDose 4D mode can reduce radiation dose effectively comparing using ECG mode alone, and that ECG and CAREDose 4D mode should be widely applied clinically with appropriate initial settings. (authors)

  7. Electrocardiographic changes is patients with esophageal carcinoma exposed to radiotherapy by a continuous and split course

    Energy Technology Data Exchange (ETDEWEB)

    Sarkisyan, Yu Kh; Goncharova, I M; Kallistova, L P; Syromyatnikova, E N; Slaviner, S I; Abramchenko, Yu A [Nauchno-Issledovatel' skij Inst. Rentgenologii i Radiologii, Moscow (USSR)

    1980-10-01

    An analysis of clinical, electrocardiographic, roentgenological and biochemical changes was made in 170 patients with esophageal carcinoma before, during and after radiation therapy conducted by a continuous (34 patients) and split course (136 patients). A rise in sinus tachycardia, appearance of extrasystolia and His' bundle right branch block, lowering of the ST-segment, flattening or appearance of negative T wave, an increase in the activity of creatine phosphokinase and aspartate aminotransferase in the blood serum were noted in a number of patients during radiation therapy. The changes were observed more often and were more marked in patients who had received continuous telegammatherapy. Irrespective of the method of radiotherapy in the restoration of the processes of excitation and conduction, improvement of metabolism in the cardiac muscle, a decrease in dysproteinemia, an increase in the content of electrolytes in the blood were noted.

  8. High-tension electrical injury to the heart as assessed by radionuclide imaging

    Energy Technology Data Exchange (ETDEWEB)

    Iino, Hitoshi; Chikamori, Taishiro; Hatano, Tsuguhisa [Tokyo Medical Coll. (Japan)] [and others

    2002-12-01

    The purpose of this study was to evaluate cardiac complications associated with electrical injury, 7 patients with high-tension electrical injury (6,600 V alternating current) underwent {sup 201}Tl and {sup 123}I-metaiodobenzylguanidine (MIBG) imaging in addition to conventional electrocardiographic and echocardiographic assessments. Electrocardiography showed transient atrial fibrillation, second degree atrioventricular block, ST-segment depression, and sinus bradycardia in each patient. Echocardiography showed mild hypokinesis of the anterior wall in only 2 patients, but {sup 201}Tl and {sup 123}I-MIBG myocardial scintigraphy showed an abnormal scan image in 6/7 and 5/6 patients, respectively. Decreased radionuclide accumulation was seen primarily in areas extending from the anterior wall to the septum. Decreased radionuclide accumulation was smaller in extent and milder in degree in {sup 123}I-MIBG than in {sup 201}Tl imaging. These results suggest that even in patients without definite evidence of severe cardiac complications in conventional examinations, radionuclide imaging detects significant damage due to high-tension electrical injury, in which sympathetic nerve dysfunction might be milder than myocardial cell damage. (author)

  9. LONG-TERM EFFECTS OF CHLORTHALIDONE VS HYDROCHLOROTHIAZIDE ON ELECTROCARDIOGRAPHIC LEFT VENTRICULAR HYPERTROPHY IN THE MULTIPLE RISK FACTOR INTERVENTION TRIAL

    Science.gov (United States)

    Ernst, Michael E.; Neaton, James D.; Grimm, Richard H.; Collins, Gary; Thomas, William; Soliman, Elsayed Z.; Prineas, Ronald J.

    2011-01-01

    Chlorthalidone (CTD) reduces 24-hour blood pressure more effectively than hydrochlorothiazide (HCTZ), but whether this influences electrocardiographic left ventricular hypertrophy (LVH) is uncertain. One source of comparative data is the Multiple Risk Factor Intervention Trial (MRFIT), which randomly assigned 8,012 hypertensive men to special intervention (SI) or usual care (UC). SI participants could use CTD or HCTZ initially; previous analyses have grouped clinics by their main diuretic used (C-clinics: CTD; H-clinics: HCTZ). After 48 months, SI participants receiving HCTZ were recommended to switch to CTD, in part, because higher mortality was observed for SI compared to UC participants in H-clinics, while the opposite was found in C-clinics. In this analysis, we examined change in continuous measures of electrocardiographic LVH using both an ecologic analysis by previously-reported C- or H-clinic groupings, and an individual participant analysis where use of CTD or HCTZ by SI participants was considered and updated annually. Through 48 months, differences between SI and UC in LVH were larger for C-clinics compared to H-clinics (Sokolow-Lyon: −93.9 vs −54.9 μV, P=0.049; Cornell voltage: −68.1 vs −35.9 μV, P=0.019; Cornell voltage product: −4.6 vs −2.2 μV/ms, P=0.071; left ventricular mass: −4.4 vs −2.8 gm, P=0.002). At the individual participant level, Sokolow-Lyon and left ventricular mass were significantly lower for SI men receiving CTD compared to HCTZ through 48 months and 84 months of follow-up. Our findings on LVH support the idea that greater blood pressure reduction with CTD than HCTZ may have led to differences in mortality observed in MRFIT. PMID:22025372

  10. Transtelephonic Electrocardiographic Transmission in the Preparticipation Screening of Athletes

    Directory of Open Access Journals (Sweden)

    Theodoros Samaras

    2008-01-01

    Full Text Available Transtelephonic electrocardiographic transmission (TET is the most widespread form of telecardiology since it enables clinicians to assess patients at a distance. The purpose of this study was to assess the efficacy and effectiveness of TET either by fixed telephone line (POTS or by mobile phone in the preparticipation screening of young athletes. A total of 506 players, aged 20.5 ± 6.2 years, from 23 soccer clubs in the prefecture of Thessaloniki, Greece, were physically examined in their playfields by a general practitioner (GP and had their ECG recorded. In 142 cases, and on the judgment of the GP, the ECG was transmitted via POTS and/or global system for mobile communications (GSM to a specialised medical centre where it was evaluated by a cardiologist. The mean total time for recording, storing, and transmitting the ECG was four minutes per subject. It was found that the success rate for transmission at first attempt was similar for both fixed and mobile networks, that is, 93% and 91%, respectively. The failure rate in the GSM network was correlated to the reception level at the site of transmission. Only in about half ( = 74 of the transmitted ECGs did the cardiologist confirm “abnormal” findings, although in 16, they were considered to be clinically insignificant. Consequently, 58 athletes were referred for further medical examination. Our results indicate that TET (either by fixed telephone line or by mobile phone can ensure valid, reliable, and objective measurements, and significantly contribute to the application of medical screening in a great number of athletes. Therefore, it is recommended as an alternative diagnostic tool for the preparticipation screening of athletes living in remote areas.

  11. Role of electrocardiographic changes in discriminating acute or chronic right ventricular pressure overload.

    Science.gov (United States)

    Can, Mehmet Mustafa; Özveren, Olcay; Biteker, Murat; Şengül, Cihan; Uz, Ömer; Işılak, Zafer; Kırılmaz, Ata

    2013-06-01

    Pulmonary embolism (PE) and severe pulmonary stenosis (PS) are two distinct conditions accompanied by increased pressure load of the right ventricle (RV). Despite major advances in our understanding of the mechanisms of RV adaptation to the increased pressure, substantial gaps in our knowledge remain unsettled. One of much less known aspect of pressure overload of RV is its impact on electrocardiographic (ECG) changes. In this study, we aimed to study whether acute and chronic RV overload are accompanied by different ECG patterns. Thirty-eight patients with PE underwent ECG monitoring were compared with 20 matched patients with PS in this observational retrospective study. ECG abnormalities suggestive of RV overload were recorded and analyzed in both groups. Logistic regression analysis was used to define the predictors of chronic RV overload. Among the ECG changes studied, premature atrial contraction (OR-12.2, 95% CI, 1.3-107, p=0.008), right axis deviation (OR-20.4, 95% CI 4.2-98, poverload. Our data indicate that the ECG changes that attributed to the acute RV pressure loading states may be more prevalent in chronic RV overload as compared with acute RV overload.

  12. Acute myocardial infarction associated with intravenous dipyridamole for rubidium-82 PET imaging

    International Nuclear Information System (INIS)

    Marwick, T.H.; Hollman, J.

    1990-01-01

    This report describes the occurrence of chest pain and electrocardiographic features of acute myocardial infarction following intravenous dipyridamole-handgrip stress. Myocardial perfusion imaging (Rb-82 PET) demonstrated a stress-induced perfusion defect. Following failure to respond to medical therapy, urgent cardiac catheterization demonstrated total occlusion of the left anterior descending coronary artery. The vessel was revascularized, with limitation of myocardial damage evidenced by failure to develop anterior Q waves and only modest elevation of cardiac enzyme levels. Complications of intravenous dipyridamole stress are rare, this case constituting the first major problem in over 500 such procedures at this institution. However, this experience demonstrates the importance of vigilant observation during the performance of this technique

  13. Energy-efficient key distribution using electrocardiograph biometric set for secure communications in wireless body healthcare networks.

    Science.gov (United States)

    Shi, Jinyang; Lam, Kwok-Yan; Gu, Ming; Li, Mingze; Chung, Siu-Leung

    2011-10-01

    Wireless body sensor network (WBSN) has gained significant interests as an important infrastructure for real-time biomedical healthcare systems, while the security of the sensitive health information becomes one of the main challenges. Due to the constraints of limited power, traditional cryptographic key distribution schemes are not suitable for WBSN. This paper proposes a novel energy-efficient approach, BodyKey, which can distribute the keys using the electrocardiograph biometrics. BodyKey represents the biometric features as ordered set, and deals with the biometric variations using set reconciliation. In this way, only limited necessary information needs to be communicated for key agreement, and the total energy consumption for key distribution can thus be reduced. Experiments on the PhysioBank Database show that BodyKey can perform an energy consumption rate of 0.01 mJ/bit with an equal accuracy rate of 97.28%, allowing the system to be used as an energy-efficient key distribution scheme for secure communications in WBSN.

  14. Receiver operating characteristic (ROC) curves and the definition of threshold levels to diagnose coronary artery disease on electrocardiographic stress testing. Part II: the use of ROC curves in the choice of electrocardiographic stress test markers of ischaemia.

    Science.gov (United States)

    Marazìa, Stefania; Barnabei, Luca; De Caterina, Raffaele

    2008-01-01

    A common problem in diagnostic medicine, when performing a diagnostic test, is to obtain an accurate discrimination between 'normal' cases and cases with disease, owing to the overlapping distributions of these populations. In clinical practice, it is exceedingly rare that a chosen cut point will achieve perfect discrimination between normal cases and those with disease, and one has to select the best compromise between sensitivity and specificity by comparing the diagnostic performance of different tests or diagnostic criteria available. Receiver operating characteristic (or receiver operator characteristic, ROC) curves allow systematic and intuitively appealing descriptions of the diagnostic performance of a test and a comparison of the performance of different tests or diagnostic criteria. This review will analyse the basic principles underlying ROC curves and their specific application to the choice of optimal parameters on exercise electrocardiographic stress testing. Part II will be devoted to the comparative analysis of various parameters derived from exercise stress testing for the diagnosis of underlying coronary artery disease.

  15. Electrocardiographic and hemato-biochemical effects of two balanced anesthetic protocols in dogs

    Directory of Open Access Journals (Sweden)

    Anubhav Khurana

    2014-10-01

    Full Text Available Aim: The purpose of this study was to compare the electrocardiographic (ECG, hematological and clinico-biochemical effects of two balanced anesthetic protocols in dogs. Materials and Methods: A total of 20 clinical cases of dogs, randomly divided into two groups of 10 animals each were made part of study. All dogs were premedicated with injection atropine sulfate @ 0.04 mg/kg body weight (b. wt. subcutaneously followed 15 min later with injection butorphanol tartarate @ 0.2 mg/kg b. wt. intravenous (IV. Subsequently after 10 min premedicated with injection diazepam @ 0.5 mg/kg b. wt. IV (Group DP or injection acepromazine maleate @ 0.015 mg/kg b. wt. IV (Group AP followed by injection propofol “till effect” IV for induction of surgical anesthesia. The animals were immediately transferred to halothane in oxygen. Observations recorded in dogs included ECG recordings, hematological and clinico-biochemical observations at various time intervals. Results: No arrhythmia was observed in any animal pre-operatively and intra-operatively in any of the groups. Significant fall in packed cell volume (PCV and total erythrocyte count occurred in DP group in early phase, whereas only PCV decreased significantly in AP group. Biochemical parameters were non-significant in both the groups. Conclusion: Both diazepam-butorphanol-propofol-halothane and acepromazine-butorphanol-propofol-halothane are safe with respect to their ECG, hematological and biochemical effects in clinical cases.

  16. Standard electrocardiographic values in Holstein calves Valores eletrocardiográficos normais para bezerros holandeses

    Directory of Open Access Journals (Sweden)

    L.C.N. Mendes

    2001-12-01

    Full Text Available This paper presents electrocardiographic values in 25 Holstein calves using the standard bipolar limbs leads (I, II and III, augmented unipolar limb leads (avL, avR and avF and a bipolar chest lead (V10. Two groups with different ages were compared (newborn - 18 to 72 hours and calves - 27 to 33 days old. It was concluded that no differences between age groups in P, Q, R, S and T waves, in the PR, QRS, QT and ST intervals and in axis orientation were observed.Este artigo apresenta valores eletrocardiográficos de 25 bezerros da raça Holandesesa, utilizando-se as derivações bipolares de membro (I, II, III, unipolares aumentadas de membro (avL, avR e avF e uma derivação bipolar de torax (V10. Dois grupos com animais de diferentes idades foram comparados (18 a 72 horas e 27 a 33 dias de idade. Conclui-se que não houve diferença significativa entre os grupos nas ondas P, Q, R, S e T, nos intervalos PR, QRS, QT e ST e no eixo cardíaco.

  17. Right heart enlargement in heartworm-infected dogs: a radiographic, electrocardiographic, and echocardiographic correlation

    International Nuclear Information System (INIS)

    Lombard, C.W.; Ackerman, N.

    1984-01-01

    Radiographically, the size of the right ventricle of 54 heartworm-infected dogs was graded subjectively as normal, 1 +, 2 +, and 3 + and served to classify the dogs into groups A, B, C, and D. With M-mode echocardiograms, right ventricular enlargement ratios (RVE ratios) were determined for each dog by dividing the measured right ventricular internal diastolic dimension (RVIDd) by the expected RVIDd of a normal dog of the same body weight. The normal RVIDd relation to body weight was derived from 25 healthy heartworm-free control dogs. These two variables were linearly related with a correlation coefficient r 2 = 0.59. Means and standard deviations of the RVE ratio were calculated for each group. Despite wide ranges and considerable overlap, the ratio was significantly different (t-test, p < 0.005) between groups with the exception of groups A and B, and C and D. The incidence of electrocardiographic signs of right ventricular hypertrophy was also determined for each group; it was 38% in group C and 62% in group D. From this data, it was concluded that M-mode echocardiography is a very sensitive technique for the documentation of right ventricular dilatation in heartworm-infected dogs, correlating with radiographic impressions of right ventricular enlargement. (author)

  18. Estimation of the displacement of cardiac substructures and the motion of the coronary arteries using electrocardiographic gating

    Directory of Open Access Journals (Sweden)

    Tan W

    2013-09-01

    Full Text Available Wenyong Tan,1,* Liying Xu,2,* Xiaohong Wang,1 Dasheng Qiu,3 Guang Han,1 Desheng Hu1 1Department of Radiation Oncology, Hubei Cancer Hospital, Wuhan, People’s Republic of China; 2Department of Radiology, Zhongnan Hospital, Wuhan University, Wuhan, People’s Republic of China; 3PET-CT Center, Hubei Cancer Hospital, Wuhan, People’s Republic of China *These authors have contributed equally to this paper Purpose: The aim of this study was to quantify the displacement of cardiac substructures, including the anterior myocardial territory (AMT, left ventricle, and coronary arteries during a normal cardiac cycle. Materials and methods: Computed tomography (CT images with retrospective electrocardiographic gating of 17 eligible patients were obtained. All images were reconstructed automatically for the end-diastolic and end-systolic phases. CT scanning without contrast at a random phase and a selected vertebral body were used as references to measure three-dimensionaldisplacements of the cardiac substructures. Results: The displacement between the end-diastolic and end-systolic phases (Dd-s was greater than that between the end-systolic and random phases and between the end-diastolic and random cardiac phases. The largest displacements for the heart were in the left, posterior, and inferior directions with an average Dd-s of approximately 4–6 mm. The average Dd-s for the AMT and left ventricle was 1.2–2.7 mm in the anterior and right directions, 4.3–7.8 mm in left and posterior directions, and 4.9–6.3 mm in superior and inferior directions. For the coronary arteries, the average Dd-s was 2.8–5.9 mm in the anterior-posterior direction, 3.5–6.6 mm in left-right direction, and 3.8–5.3 mm in the superior-inferior direction. Inter-observer agreement was excellent for the heart, AMT, and left ventricle (kappa coefficient, >0.75 for all and good for most coronary arteries in three dimensions (kappa coefficient, 0.511–0.687. The Dd-s did not

  19. Thallium-201 stress imaging in hypertensive patients

    International Nuclear Information System (INIS)

    Schulman, D.S.; Francis, C.K.; Black, H.R.; Wackers, F.J.

    1987-01-01

    To assess the potential effect of hypertension on the results of thallium-201 stress imaging in patients with chest pain, 272 thallium-201 stress tests performed in 133 hypertensive patients and 139 normotensive patients over a 1-year period were reviewed. Normotensive and hypertensive patients were similar in age, gender distribution, prevalence of cardiac risk factors (tobacco smoking, hyperlipidemia, and diabetes mellitus), medications, and clinical symptoms of coronary disease. Electrocardiographic criteria for left ventricular hypertrophy were present in 16 hypertensive patients. Stepwise probability analysis was used to determine the likelihood of coronary artery disease for each patient. In patients with mid to high likelihood of coronary disease (greater than 25% probability), abnormal thallium-201 stress images were present in 54 of 60 (90%) hypertensive patients compared with 51 of 64 (80%) normotensive patients. However, in 73 patients with a low likelihood of coronary disease (less than or equal to 25% probability), abnormal thallium-201 stress images were present in 21 patients (29%) of the hypertensive group compared with only 5 of 75 (7%) of the normotensive patients (p less than 0.001). These findings suggest that in patients with a mid to high likelihood of coronary artery disease, coexistent hypertension does not affect the results of thallium-201 exercise stress testing. However, in patients with a low likelihood of coronary artery disease, abnormal thallium-201 stress images are obtained more frequently in hypertensive patients than in normotensive patients

  20. The T wave in the V10 precordial electrocardiographic lead is negative in healthy Chihuahua dogs.

    Science.gov (United States)

    Dijkstra, Marieke; Szatmári, Viktor

    2009-12-01

    The T wave polarity in the V10 precordial electrocardiographic (ECG) lead in Chihuahuas is described as positive in the veterinary literature. The aim of this study was to investigate the polarity of the T wave in the V10 precordial ECG lead in clinically healthy Chihuahuas. Our null hypothesis was that healthy Chihuahuas have a negative T wave in V10. In this prospective study, 67 healthy breeder-owned Chihuahuas were used. A physical examination, 10-lead ECG and an echocardiogram were performed on each dog. No cardio-respiratory abnormalities were revealed in any of the otherwise healthy dogs. Three out of 67 ECGs were of insufficient quality because of baseline artifacts due to movement of the animal. Two other ECGs showed a nearly iso-electric T wave in the V10 lead. The remaining 62 ECGs showed negative T waves in the V10 lead. Right ventricular hypertrophy was excluded with echocardiography in all dogs. In contrast to previous reports, we found that healthy Chihuahuas have negative T wave in the V10 precordial ECG lead.

  1. Receiver operating characteristic (ROC) curves and the definition of threshold levels to diagnose coronary artery disease on electrocardiographic stress testing. Part I: The use of ROC curves in diagnostic medicine and electrocardiographic markers of ischaemia.

    Science.gov (United States)

    Barnabei, Luca; Marazìa, Stefania; De Caterina, Raffaele

    2007-11-01

    A common problem in diagnostic medicine, when performing a diagnostic test, is to obtain an accurate discrimination between 'normal' cases and cases with disease, owing to the overlapping distributions of these populations. In clinical practice, it is exceedingly rare that a chosen cut point will achieve perfect discrimination between normal cases and those with disease, and one has to select the best compromise between sensitivity and specificity by comparing the diagnostic performance of different tests or diagnostic criteria available. Receiver operating characteristic (or receiver operator characteristic, ROC) curves allow systematic and intuitively appealing descriptions of the diagnostic performance of a test and a comparison of the performance of different tests or diagnostic criteria. This review will analyse the basic principles underlying ROC curves and their specific application to the choice of optimal parameters on exercise electrocardiographic (ECG) stress testing. Part I will focus on theoretical description and analysis along with reviewing the common problems related to the diagnosis of myocardial ischaemia by means of exercise ECG stress testing. Part II will be devoted to applying ROC curves to available diagnostic criteria through the analysis of ECG stress test parameters.

  2. An extended chain Ising model and its Glauber dynamics

    International Nuclear Information System (INIS)

    Zhao Xing-Yu; Fan Xiao-Hui; Huang Yi-Neng; Huang Xin-Ru

    2012-01-01

    It was first proposed that an extended chain Ising (ECI) model contains the Ising chain model, single spin double-well potentials and a pure phonon heat bath of a specific energy exchange with the spins. The extension method is easy to apply to high dimensional cases. Then the single spin-flip probability (rate) of the ECI model is deduced based on the Boltzmann principle and general statistical principles of independent events and the model is simplified to an extended chain Glauber—Ising (ECGI) model. Moreover, the relaxation dynamics of the ECGI model were simulated by the Monte Carlo method and a comparison with the predictions of the special chain Glauber—Ising (SCGI) model was presented. It was found that the results of the two models are consistent with each other when the Ising chain length is large enough and temperature is relative low, which is the most valuable case of the model applications. These show that the ECI model will provide a firm physical base for the widely used single spin-flip rate proposed by Glauber and a possible route to obtain the single spin-flip rate of other form and even the multi-spin-flip rate. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  3. Pertinence between the tombstoning electrocardiographic pattern of ST-segment change and infarcted artery orientation in acute myocardial infarction

    International Nuclear Information System (INIS)

    Deng Min; Ma Qianjun; Song Jianping

    2005-01-01

    Objective: The aim of this study is to address the pertinence between the tombstoning electrocardiographic pattern of ST-segment change and infracted artery orientation in acute myocardial infarction. Methods: The study investigated 104 patients with AMI, who subsequently underwent angiography. In this population, 19 patients had a definite tombstoning pattern on their admission ECG. Results: Between tombstoning ECGs and non-tombstoning, campared CAG, the results were as follows: tombstoning ECGs were more strongly associated with anterior infarction and significantly influence the left anterior descending (LAD) artery (P<0.001); LAD occlusions were significantly more severe, mostly proximal (P<0.05, P<0.01); tombstoning ECGs were significantly greater incidence of occlusion of multivessel coronary artery (P<0.05). Conclusions: Although tombstoning ECGs correlates with the occlusion of a high-grade stenosis of the proximal LAD and severe abnormal ventricle wall motion, it is still greatly necessary to reperfuse and revascularize so as to ameliorate the prognosis. (authors)

  4. Mechanism underlying the absence of ischemic changes on the exercise electrocardiogram in patients with abnormal exercise thallium-201 imaging and coronary artery disease

    International Nuclear Information System (INIS)

    Coplan, N.L.; Horowitz, S.F.; Hoffman, D.P.; Goldman, M.E.; Machac, J.

    1985-01-01

    Patients with coronary artery disease may have reversible abnormalities on a thallium myocardial perfusion study without simultaneous ischemic changes on the exercise electrocardiogram, but the mechanisms responsible for this disparity have not been fully elucidated. A group of 37 patients with angiographically demonstrated coronary artery disease and abnormal thallium perfusion imaging were divided into two groups on the basis of their exercise electrocardiographic ST segment response. Thirteen patients (Group A) had no significant electrocardiographic changes with exercise, while 24 patients (Group B) had ST changes consistent with ischemia during the test. There were no significant differences in clinical or angiographic characteristics between the two groups. Stress test results showed a similar mean duration of exercise in the two groups, but the patients in Group A achieved a significantly lower mean maximal heart rate and mean maximal double product. These results suggest that exercise thallium-electrocardiogram discordance is mediated by the level of myocardial workload achieved. An abnormal perfusion scan accompanying an exercise electrocardiogram which does not demonstrate any ischemic ST change may occur when there is sufficient increase in myocardial oxygen demand to result in differential augmentation of myocardial blood flow, but insufficient imbalance of supply and demand to result in signs of ischemia on the surface electrocardiogram

  5. The Acoustic Lens Design and in Vivo Use of a Multifunctional Catheter Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    Science.gov (United States)

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David

    2009-01-01

    A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850

  6. Electrocardiographic alteration among first degree relatives with serologic evidence of Trypanosoma cruzi infection: a sibship study

    Directory of Open Access Journals (Sweden)

    Julio C. Morini

    1994-09-01

    Full Text Available To analyze whether electrocardiographic alterations (ECGA in patients with antibodies to Trypanosoma cruzi showed a patttern of familial aggregation, a sample of 379 young adults (166 men and 213 women distributed in sibships, were assessed for the presence of anti-T.cruzi antibodies, and subjected to a complete clinical examination and a standard resting electrocardiogram (ECG. Positive T. cruzi serology was detected in 165 individuals, 48 of them showing an abnormal ECG (overall prevalence 29 por cento. One hundred and eleven seropositive individuals were distributed in 45 sibships, each of them constituted by more than one seropositive sib, with ECGA being present in 34 out of these patients. Seropositive subjects with ECGA were detected in 27 sibships. Since the index case within each sibship is counted exactly once, affected individuals selected at random as propositi were extracted to calculate the prevalence of ECGA among first degree relatives of probands. Abnormal ECGs were recorded in 7 out of 45 sibs yielding a prevalence that did not differ from estimations registered in the general population or seropositive sibs. Data from the present sample show no familial aggregation for the occurrence of ECGA in patients with T.cruzi infection.

  7. A comparative study for the echo cardiographic, radiologic and electrocardiographic presentation of the sport heart hypertrophy

    International Nuclear Information System (INIS)

    Reinke, A.

    1982-01-01

    In this work the three most important non-invasive methods - X-ray pictures, electrocardiography and echo cardiography - were compared as to their ability to evaluate the physiological heart enlargement as a result of physical training. Important also was the study of the value of ultrasonic cardiographs. The subjects used were 162 athletes, 36 patients with cardiovascular diseases, and 22 non-athletic control persons. Radiologically the changes in the total size of the heart were determined. For the question of the adapting reaction of the heart because of athletic training the weight-related heart volume is more meaningful than the absolute value. Electrocardiographically it is not possible to come up with any statistically significant statements about the physiological heart enlargement using the Sokoloff-Lyon indexes. Echo cardiographically the regulative heart enlargements can be differentiated into myocardial hypertrophy or ventricular dilation. As a result of this a line can be drawn between physiological and pathological changes. Female athletes show qualitatively, but not quantitatively, the same adapting reaction. The synopsis of the three procedures shows that echo cardiography and radiology show better results than does electrocardiography. Together the methods complement each other in their diagnostic power. (orig./TRV) [de

  8. Electrocardiographic PR prolongation and atrial fibrillation risk: a meta-analysis of prospective cohort studies.

    Science.gov (United States)

    Cheng, Min; Lu, Xiangfeng; Huang, Jianfeng; Zhang, Shu; Gu, Dongfeng

    2015-01-01

    Electrocardiographic PR interval prolongation is considered a benign condition, but recent studies have challenged the notion by demonstrating that prolonged PR interval is associated with an increased risk of atrial fibrillation (AF). The purpose of this study was to perform a meta-analysis of prospective cohort studies to evaluate the evidence supporting an association of prolonged PR interval with AF incidence. We searched the MEDLINE and EMBASE database (from inception to May 2014) supplemented by manual searches of references of relevant retrieved articles. Prospective cohort studies were included with hazard ratio (HR) of prolonged PR interval for incident AF. The search strategy yielded 6 cohort studies meeting eligibility criteria. A total of 328,932 participants were included, with 14,191 participants suffering from AF during follow-up. Pooled HRs of prolonged PR interval for incident AF was 1.30 (95% CI: 1.13 to 1.49) using random-effect model (I(2) = 30%). There was a significant difference of combined HRs between studies with and without adjustment for taking of AV nodal blocking agents in subgroup analysis. Sensitivity analysis supported the robustness of the results. Prolonged PR interval is not a totally benign condition but an independent risk factor for AF incidence. The mechanisms underlying the association of prolonged PR interval with AF incidence need further research. © 2014 Wiley Periodicals, Inc.

  9. Assessment of thoracic aortic elasticity: a preliminary study using electrocardiographically gated dual-source CT

    International Nuclear Information System (INIS)

    Li, Ning; Guo, Lijun; Sun, Haitao; Gao, Fei; Liu, Cheng; Beck, Thomas; Chen, Jiuhong; Biermann, Christina

    2011-01-01

    To gain a new insight into the elastic properties of the thoracic aorta in patients without aortic diseases using electrocardiographically (ECG)-gated dual-source (DS) CT. 56 subjects with no cardiovascular disease, selected from 2,700 people undergoing ECG-gated DSCT examination, were divided into three groups according to their age. CT data were reconstructed in 5% step throughout the RR interval. Diameter and area were measured at the curve of the ascending aorta (AA) and at the same level of the descending aorta (DA). The pulsation and elasticity of the aorta were evaluated. Aortic diameter changes were noted throughout the cardiac cycle. The maximum average diameter was seen at an RR interval of 24.02 ± 4.99% for the AA and 25.63 ± 4.77% for the DA. The minimum was at 93.5 ± 4.04% for the AA and 96.6 ± 4.58% for the DA. There was an age-dependent decrease in elasticity, while different correlation coefficients were found between various age groups and different elastic parameters. The properties of aortic pulsation and wall elasticity could be well shown by ECG-gated DSCT. The new findings regarding segment difference and age relevance were significant and should be taken into account in clinical trials and treatments for the elasticity related cardiovascular diseases. (orig.)

  10. Evaluation of Electrocardiographic Changes after Arterial Switch Operation

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2014-09-01

    Full Text Available Background: Transposition of Great Arteries (TGA is a serious congenital heart disease which can be accompanied by good outcomes with anatomic correction within the first few weeks of life. Objectives: The present study aimed to evaluate electrocardiographic changes in the children with uncomplicated Arterial Switch Operation (ASO. Patients and Methods: Twelve lead electrocardiograms were obtained from thirty-three patients with TGA after ASO. Then, the patients’ QT-dispersion and P-wave dispersion were compared to those of 33 age- and gender-matched individuals as the normal control group. Both groups were also evaluated by M-mode echocardiography. Student’s t-test and Pearson correlation were used to analyze the data. Besides, P < 0.05 was considered as statistically significant. Results: The mean age of the patients and the control group was 41 ± 3.7 and 40.12 ± 4.2 months, respectively. Comparison of P wave, T wave, QRS complex, PR interval, QT segment, and corrected QT segment showed significant differences in the frequency of inverted T wave in pericardial leads [V3, V4, V5, and V6] (P = 0.004; more in patients, P wave amplitude in lead II (P < 0.001; more in patients, R wave amplitude in V1 (P = 0.016; smaller in patients, R and S waves amplitude in V6 (P = 0.004 and P = 0.001; taller in patients, corrected QT segment (in lead V5; P < 0.0001: prolonger in patients, and PR interval (P = 0.001; prolonger in patients. However, no significant differences were found regarding the vector axis and heart rate. Right bundle branch block (18% vs. 0%, Bifascicular (3% vs. 0%, and first-degree blocks (15% vs. 0% were significantly more in the patients. Besides, the PR interval was longer in the corrected complex TGA (146 ± 24.4 vs. 127.7 ± 23.1, P = 0.001. Moreover, R/S ratio in lead V1 was significantly prolonger, among the patients (2.86 ± 3.35 vs. 0.706 ± 0.53, P = 0.002. Nonetheless, no significant was observed between the patients and

  11. Detection of microsleep events in a car driving simulation study using electrocardiographic features

    Directory of Open Access Journals (Sweden)

    Lenis Gustavo

    2016-09-01

    Full Text Available Microsleep events (MSE are short intrusions of sleep under the demand of sustained attention. They can impose a major threat to safety while driving a car and are considered one of the most significant causes of traffic accidents. Driver’s fatigue and MSE account for up to 20% of all car crashes in Europe and at least 100,000 accidents in the US every year. Unfortunately, there is not a standardized test developed to quantify the degree of vigilance of a driver. To account for this problem, different approaches based on biosignal analysis have been studied in the past. In this paper, we investigate an electrocardiographic-based detection of MSE using morphological and rhythmical features. 14 records from a car driving simulation study with a high incidence of MSE were analyzed and the behavior of the ECG features before and after an MSE in relation to reference baseline values (without drowsiness were investigated. The results show that MSE cannot be detected (or predicted using only the ECG. However, in the presence of MSE, the rhythmical and morphological features were observed to be significantly different than the ones calculated for the reference signal without sleepiness. In particular, when MSE were present, the heart rate diminished while the heart rate variability increased. Time distances between P wave and R peak, and R peak and T wave and their dispersion increased also. This demonstrates a noticeable change of the autonomous regulation of the heart. In future, the ECG parameter could be used as a surrogate measure of fatigue.

  12. Comparison of transaxial source images and 3-plane, thin-slab maximal intensity projection images for the diagnosis of coronary artery stenosis with using ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Seo, Joon Beom; Do, Kyung Hyun

    2006-01-01

    We wanted to compare the transaxial source images with the optimized three plane, thin-slab maximum intensity projection (MIP) images from electrocardiographic (ECG)-gated cardiac CT for their ability to detect hemodynamically significant stenosis (HSS), and we did this by means of performing a receiver operating characteristic (ROC) analysis. Twenty-eight patients with a heart rate less than 66 beats per minute and who were undergoing both retrospective ECG-gated cardiac CT and conventional coronary angiography were included in this study. The contrast-enhanced CT scans were obtained with a collimation of 16 x 0.75-mm and a rotation time of 420 msec. The tranaxial images were reconstructed at the mid-diastolic phase with a 1-mm slice thickness and a 0.5-mm increment. Using the transaxial images, the slab MIP images were created with a 4-mm thickness and a 2-mm increment, and they covered the entire heart in the horizontal long axis (4 chamber view), in the vertical long axis (2 chamber view) and in the short axis. The transaxial images and MIP images were independently evaluated for their ability to detect HSS. Conventional coronary angiograms of the same study group served as the standard of reference. Four radiologists were requested to rank each image with using a five-point scale (1 = definitely negative, 2 = probably negative, 3 = indeterminate, 4 = probably positive, and 5 definitely positive) for the presence of HSS; the data were then interpreted using ROC analysis. There was no statistical difference in the area under the ROC curve between transaxial images and MIP images for the detection of HSS (0.8375 and 0.8708, respectively; ρ > 0.05). The mean reading time for the transaxial source images and the MIP images was 116 and 126.5 minutes, respectively. The diagnostic performance of the MIP images for detecting HSS of the coronary arteries is acceptable and this technique's ability to detect HSS is comparable to that of the transaxial source images

  13. The relationship of cardiovascular risk factors and electrocardiographic findings: Isfahan Healthy Heart Program

    Directory of Open Access Journals (Sweden)

    Nizal Sarrafzadegan

    2012-03-01

    Full Text Available    BACKGROUND: Cardiovascular disease (CVD is the leading cause of mortality worldwide. Various studies showed relationship between electrocardiographic (ECG changes at rest and CVD mortality. Present study was performed to find the relation between ECG and CVD risk factors in an Iranian population.    METHODS: This cross-sectional study was performed on 3343 subjects aged ≥ 35 years from three provincial cities of Isfahan, Arak, and Najafabad. Demographic and lifestyle information, as well as weight, height, blood pressure, hip and waist circumference measurement was recorded. Laboratory tests including total cholesterol (TC, LDL-C, HDL-C, triglycerides (TG and fasting serum glucose were measured too. Ischemic criteria of ECG included minor and major changes in ST segment, T wave, conductive disorders, blocks and arrhythmias.    RESULTS: Ischemic changes in women were 1.5 times more than men (P < 0.05. Mean age of  the group with ischemic findings was 5 years more than non-Ischemic group. Comparison of lifestyle variables indicated that physical activity in reverse to nutrient index was significantly more in non-ischemic individuals compared to the ischemic individuals. Smoking showed a significant difference between the two groups, too (P < 0.05. Anthropometric variables including body mass index (BMI, hip and waist circumference and diabetic and systolic blood pressure as well as biochemical factors including TC, HDL-C, and LDL-C were significantly higher in Ischemic group (P < 0.05.    CONCLUSION: Considering the ischemic change in individuals with unhealthy life style or with CVD risk factors, these should be considered in evaluation of these patients.         Keywords: Ischemic Changes, Electrocardiography, Cardiovascular Risk Factors.

  14. Intracardiac electrocardiographic assessment of precordial TASER shocks in human subjects: A pilot study.

    Science.gov (United States)

    Stopyra, Jason P; Winslow, James E; Fitzgerald, David M; Bozeman, William P

    2017-11-01

    Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead. Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled. Sterile subcutaneous electrodes were placed at the right sternoclavicular junction and the left lower costal margin at the midclavicular line. A standard police issue TASER Model X26 CEW was attached to the subcutaneous electrodes and a 5 s discharge was delivered. Continuous surface and intracardiac EKG monitoring was performed. A total of 157 subjects were reviewed for possible inclusion and 21 were interviewed. Among these, 4 subjects agreed and completed the study protocol. All subjects tolerated the 5 s CEW discharge without clinical complications. There were no significant changes in mean heart rate or blood pressure. Interrogation of the devices after CEW discharge revealed no ventricular pacing, dysrhythmias, damage or interference with the implanted devices. In this pilot study, we have successfully navigated the regulatory hurdles and demonstrated the feasibility of performing intracardiac EKG recording during intentional precordial CEW discharges in humans. While no CEW-associated dysrhythmias were noted, the size of this preliminary dataset precludes making conclusions about the risk of such events. Larger studies are warranted and should consider exploring variations of the CEW electrode position in relation to the cardiac silhouette. Copyright © 2017. Published by Elsevier Ltd.

  15. Electrocardiographic abnormalities in acute cerebro-vascular accidents and their correlation with cerebro-spinal fluid pressure and serum electrolytes

    Directory of Open Access Journals (Sweden)

    Gambhir M

    1978-01-01

    Full Text Available Electrocardiographic studies have been carried out in 50 patients with acute cerebrovascular accidents. These cases included 31 cases from non-haemorrhagic group and 19 cases from haemor-rhagic group. `T′ or T-U wave abnormalities were seen in 63.1% of cases in haemorrhagic group and in 35.4% of cases from non-hae-morrhagic group. Abnormal prolongation of QTc interval (105% of normal i.e. 0.45 Secs. was observed in 73.6% cases from haemorrhagic group and in 35.4% of cases from non-haemorrhagic group. On comparing these two groups it was found that QTc was signi-ficantly more prolonged in patiens of haemorrhagic group than non--haemorrhagic group. The CSF pressure was found to be signi-ficantly more in patients with ECG abnormalities. However, there teas no correlation between serum electrolyte levels and ECG abnormalities. After 2 weeks, the ECG abnormalities disappeared, except in two cases from haemorrhagic group. There was no signi-ficant difference in the incidence of mortality between patient having ECG abnormalities and the patients without ECG abnormalities. In the light of these findings the probable mechanism of production of ECG changes in acute cerebrovascular accidents is discussed.

  16. Minor Electrocardiographic ST-T Change and Risk of Stroke in the General Japanese Population.

    Science.gov (United States)

    Ishikawa, Joji; Hirose, Hideo; Schwartz, Joseph E; Ishikawa, Shizukiyo

    2018-06-25

    Minor ST-T changes are frequently observed on the electrocardiogram (ECG), but the risk of stroke associated with such changes is unclear.Methods and Results:In 10,642 subjects from the Japanese general population, we evaluated minor and major ST-T changes (major ST depression ≥0.1 mV) on ECGs obtained at annual health examinations. At baseline, minor ST-T changes were found in 10.7% of the subjects and 0.5% had major ST-T changes. Minor ST-T changes were associated with older age, female gender, higher systolic blood pressure, presence of hyperlipidemia, and use of antihypertensive medication. There were 375 stroke events during the follow-up period (128.7±28.1 months). In all subjects, minor ST-T changes (HR, 2.10; 95% CI: 1.57-2.81) and major ST-T changes (HR, 8.64; 95% CI: 4.44-16.82) were associated with an increased risk of stroke, but the stroke risk associated with minor ST-T changes had borderline significance after adjustment for conventional risk factors (P=0.055). In subgroup analysis, the risk of stroke was significantly associated with minor ST-T changes in subjects who had hyperlipidemia (HR, 1.75; 95% CI: 1.15-2.67) compared to those without hyperlipidemia (HR, 1.01; 95% CI: 0.64-1.59; P for interaction=0.016), even after adjustment for ECG-diagnosed left ventricular hypertrophy. Minor ST-T changes were particularly associated with a higher risk of stroke in subjects with hyperlipidemia and this association was independent of electrocardiographic left ventricular hypertrophy.

  17. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

    Science.gov (United States)

    Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki

    2013-01-01

    This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; Ppannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.

  18. Thallium-201 myocardial imaging for evaluation of pulmonary hypertension

    International Nuclear Information System (INIS)

    Ikuno, Yoshiyasu

    1979-01-01

    Thallium-201 ( 201 Tl) myocardial scintigraphy (TMS) was performed in 54 patients. The images were analysed semi-quantitatively by measuring the extent of radioisotope concentration in the right ventricular free wall and the size of the right ventricular cavity. The extent of radioisotope concentration (four degrees) was expressed as the right ventricular activity score (RVAS) and the size of the right ventricular cavity (three degrees) was expressed as the right ventricular cavity score (RVCS). The scores were added for a right ventricular total score (RVTS). To establish criteria for the diagnosis of pulmonary hypertension (PH) by means of TMS, these scores were compared with the values of pulmonary arterial mean pressure (PAMP). The criteria were evaluated by comparing them with conventional criteria for electrocardiographic diagnosis of right ventricular hypertrophy. Patients with a 2-point RVAS had a significantly higher PAMP than those with a 0 or 1-point RVAS (p 201 Tl myocardial scintigrams is a useful non-invasive method for evaluating PH and its severity. (J.P.N.)

  19. Clinical value of regression of electrocardiographic left ventricular hypertrophy after aortic valve replacement.

    Science.gov (United States)

    Yamabe, Sayuri; Dohi, Yoshihiro; Higashi, Akifumi; Kinoshita, Hiroki; Sada, Yoshiharu; Hidaka, Takayuki; Kurisu, Satoshi; Shiode, Nobuo; Kihara, Yasuki

    2016-09-01

    Electrocardiographic left ventricular hypertrophy (ECG-LVH) gradually regressed after aortic valve replacement (AVR) in patients with severe aortic stenosis. Sokolow-Lyon voltage (SV1 + RV5/6) is possibly the most widely used criterion for ECG-LVH. The aim of this study was to determine whether decrease in Sokolow-Lyon voltage reflects left ventricular reverse remodeling detected by echocardiography after AVR. Of 129 consecutive patients who underwent AVR for severe aortic stenosis, 38 patients with preoperative ECG-LVH, defined by SV1 + RV5/6 of ≥3.5 mV, were enrolled in this study. Electrocardiography and echocardiography were performed preoperatively and 1 year postoperatively. The patients were divided into ECG-LVH regression group (n = 19) and non-regression group (n = 19) according to the median value of the absolute regression in SV1 + RV5/6. Multivariate logistic regression analysis was performed to assess determinants of ECG-LVH regression among echocardiographic indices. ECG-LVH regression group showed significantly greater decrease in left ventricular mass index and left ventricular dimensions than Non-regression group. ECG-LVH regression was independently determined by decrease in the left ventricular mass index [odds ratio (OR) 1.28, 95 % confidence interval (CI) 1.03-1.69, p = 0.048], left ventricular end-diastolic dimension (OR 1.18, 95 % CI 1.03-1.41, p = 0.014), and left ventricular end-systolic dimension (OR 1.24, 95 % CI 1.06-1.52, p = 0.0047). ECG-LVH regression could be a marker of the effect of AVR on both reducing the left ventricular mass index and left ventricular dimensions. The effect of AVR on reverse remodeling can be estimated, at least in part, by regression of ECG-LVH.

  20. Resting electrocardiogram and stress myocardial perfusion imaging in the determination of left ventricular systolic function: an assessment enhancing the performance of gated SPET.

    Science.gov (United States)

    Moralidis, Efstratios; Spyridonidis, Tryfon; Arsos, Georgios; Skeberis, Vassilios; Anagnostopoulos, Constantinos; Gavrielidis, Stavros

    2010-01-01

    This study aimed to determine systolic dysfunction and estimate resting left ventricular ejection fraction (LVEF) from information collected during routine evaluation of patients with suspected or known coronary heart disease. This approach was then compared to gated single photon emission tomography (SPET). Patients having undergone stress (201)Tl myocardial perfusion imaging followed by equilibrium radionuclide angiography (ERNA) were separated into derivation (n=954) and validation (n=309) groups. Logistic regression analysis was used to develop scoring systems, containing clinical, electrocardiographic (ECG) and scintigraphic data, for the discrimination of an ERNA-LVEFstatistic (mean+/-2SD) provided values of 0.001+/-0.176, 0.071+/-0.196 and 0.040+/-0.152, respectively. The average LVEF was a better discriminator of systolic dysfunction than gated SPET-LVEF in receiver operating characteristic (ROC) analysis and identified more patients (89%) with a stress myocardial perfusion imaging variables. This model provides reliable LVEF estimations, comparable to those from (201)Tl gated SPET, and can enhance the clinical performance of the latter.

  1. Impact of Heat Stress on Electrocardiographic Changes in New Zealand White Rabbits

    Directory of Open Access Journals (Sweden)

    Kour, Juneet

    2013-04-01

    Full Text Available A study was conducted on twelve clinically normal and healthy New Zealand White rabbits of both sexes, weighing between 2-3 kg, and aged between 1-3 years to observe the normal electrocardiogram and its changes during heat stress. The normal electrocardiogram and changes during heat stress were evaluated for the three bipolar standard limb leads (I, II and III and three unipolar augmented limb leads (aVR, aVL and aVF. ECG recordings were made in sternal recumbency using a multi channel electrocardiograph . The normal heart rate with a mean of 204±7 beats/min was recorded. The mean amplitude observed was 0.05±0.002 mV for P wave; 0.19±0.008 mV for QRS; 0.14±0.007 mV for T wave. The mean duration observed was 0.03±0.002 sec for P wave; 0.06±0.002 sec for PR interval; 0.05±0.003 sec for QRS complex; 0.13±0.004 sec for QT interval; 0.07±0.002 sec for T wave. During heat stress tachycardia was observed with progressive rise in temperature along with ventricular fibrillation, ventricular extra-systole and atrial fibrillation. At 43°C, ventricular fibrillation was observed in Lead II, III, aVL and aVF. At 45°C, ventricular extra-systole was recorded in Lead III, aVL and aVF. At 45°C (30 mins more exposure, ventricular extra-systole in Lead I and ventricular fibrillation in Lead III was observed. At 47°C, ventricular fibrillation was seen in Lead II, III, aVR, aVL and aVF. At 47°C (30 mins more exposure, atrial fibrillation in all the leads were observed. The mean cardiac axis recorded was 90°±0.065 without significant alterations throughout the study.

  2. The influence of the perinatal environment on the heart: morphological, electrocardiographic, and multimodality imaging features

    Directory of Open Access Journals (Sweden)

    Giuseppe Mercuro

    2015-10-01

    Full Text Available The purpose of this paper is to review the studies performed to evaluate the influence of perinatal environment on neonatal heart, detected by electrocardiography, echocardiography, and other imaging techniques. Prenatal conditions (such as intrauterine growth retardation and prematurity at birth and some post-natal events (such as perinatal asphyxia and corticosteroids administration, may have early and late detrimental effects on the heart may predispose to a number of future cardiovascular adverse events. For example, subjects born preterm may be at potentially higher risk of developing malignant ventricular arrhythmias as well. Moreover, in individuals born with an extremely low birthweight atrial septal aneurysms are present in about one third of the subjects in the study. Thus, a long-life follow up is suggested in these subjects.Proceedings of the 11th International Workshop on Neonatology and Satellite Meetings · Cagliari (Italy · October 26th-31st, 2015 · From the womb to the adultGuest Editors: Vassilios Fanos (Cagliari, Italy, Michele Mussap (Genoa, Italy, Antonio Del Vecchio (Bari, Italy, Bo Sun (Shanghai, China, Dorret I. Boomsma (Amsterdam, the Netherlands, Gavino Faa (Cagliari, Italy, Antonio Giordano (Philadelphia, USA

  3. Thyroid hormones and electrocardiographic parameters: findings from the third national health and nutrition examination survey.

    Directory of Open Access Journals (Sweden)

    Yiyi Zhang

    Full Text Available Altered thyroid status exerts a major effect on the heart. Individuals with hypo- or hyperthyroidism showed various changes in electrocardiograms. However, little is known about how variations in thyroid hormone levels within the normal range affect electrical activities of the heart in the general population.We conducted a cross-sectional analysis of 5,990 men and women from the Third National Health and Nutrition Examination Survey. Serum total T4 was measured by immunoassay and TSH was measured by chemiluminescent assay. We categorized T4 and TSH into 7 groups with cut-offs at the 5(th, 20(th, 40(th, 60(th, 80(th, and 95(th percentiles of the weighted population distribution. Electrocardiographic parameters were measured from the standard 12-lead electrocardiogram. We found a positive linear association between serum total T4 level and heart rate in men, and a U-shape association between T4 and PR interval in men and women. TSH level was positively associated with QRS interval in men, while a U-shape association between TSH and QRS was observed in women. No clear graded association between thyroid hormones and corrected QT or JT was found, except that men in the highest category of T4 levels appeared to have longer corrected QT and JT, and men in the lowest category of T4 appeared to have shorter corrected QT and JT.Variation in thyroid hormone levels in the general population, even within the normal range, was associated with various ECG changes.

  4. Prevalence of electrocardiographic changes in patients with acute aneurysmal subarachnoid hemorrhage and their relationship with outcome

    Directory of Open Access Journals (Sweden)

    Saktheeswaran Mahesh Kumar

    2013-01-01

    Full Text Available Background: Electrocardiographic (ECG alterations occurring after subarachnoid hemorrhage (SAH have been described frequently, but the prognostic significance of these changes has not been well characterized. Aim and Objectives: To report the prevalence and patterns of ECG alterations in patients with acute aneurysmal SAH and to study the relationship between ECG alterations and the neurological outcome, if any. Materials and Methods: Records of consecutive patients admitted to the neurosurgical intensive care unit of the SCTIMST, Trivandrum between January 1999 and January 2011 with acute aneurysmal SAH were retrospectively analyzed. Results: Of the 321 patients with SAH, 190 (59.2% had abnormal ECGs. Repolarization abnormalities were the most common, with T wave inversion in the anterolateral leads occurring in 155 (48.3% patients. By univariate analysis, female sex, Glasgow Coma Score (GCS at admission of I, ST segment depression or T inversion in anterolateral leads, prolonged corrected QT interval, and sinus bradycardia were associated with increased risk of death. By multivariate analysis, only GCS and WFNS grade independently predicted mortality and none of the ECG changes predicted the same. Presence of tall T waves in anterior leads, T inversion in anterolateral leads, sinus bradycardia, and WFNS grade >1 were independently associated with GCS <15 and poor outcome at discharge. Conclusions: In patients with acute aneurysmal SAH, repolarization abnormalities are the commonest ECG alterations. ECG alterations do not independently predict death, but independently predict poor discharge neurological status.

  5. Electrocardiographic spatial QRS-T angle and incident cardiovascular disease in HIV-infected patients (from the Strategies for the Management of Antiretroviral Therapy [SMART] study)

    DEFF Research Database (Denmark)

    Dawood, Farah Z; Khan, Faraaz; Roediger, Mollie P

    2013-01-01

    the baseline resting 12-lead electrocardiogram of 4,453 HIV-infected patients aged 43.5 ± 9.3 years from the Strategies for Management of Antiretroviral Therapy (SMART) trial. CVD events were identified during a median follow-up of 28.7 months. Quartiles of the spatial QRS-T angle was calculated for men......Widening of the electrocardiographic (ECG) spatial QRS-T angle has been predictive of cardiovascular disease (CVD) events in the general population. However, its prognostic significance in human immunodeficiency virus (HIV)-infected patients remains unknown. The spatial QRS-T angle was derived from...... and women separately, and values in the upper quartile were considered as a widened angle (values >74° for women and >93° for men). A multivariate Cox proportional hazards analysis was used to examine the association between a widened baseline spatial QRS-T angle and incident CVD events. During 11...

  6. Clinical and electrocardiographic characteristics of patients admitted to a thoracic pain unit in the context of a new definition of acute myocardial infarction

    International Nuclear Information System (INIS)

    Mora, Guillermo; Franco, Roberto; Fajardo, Hugo; Serrano, Daniel; Suarez, Martin

    2005-01-01

    In our environment we do ignore the clinical and para clinical characteristics from patients who come to a thoracic pain unit and more so with the new definition of acute myocardial infarction (Amid). 398 patients admitted to a thoracic pain unit were prospectively evaluated as to the pain characteristics, its risk factors, clinical examination findings, electrocardiographic findings and the troponin a T behaviour. 29.4% of the patients had a diagnosis of Amid, 29.9% of unstable angina and 40.7% of non-ischemic thoracic pain. retrosternal pain, irradiation to the neck, presence of diaphoresis, nausea or vomit are related with a higher probability to the diagnosis of Amid. Male sex and the presence of risk factors such as diabetes or dislipidemia increase the probability of the diagnosis. In the electrocardiogram, only the presence of a lesion, especially subepicardical favors the diagnosis. Unstable angina and in general acute coronary syndrome have a similar although not equal clinical behavior

  7. Maximal exercise capacity is related to cardiovascular structure in patients with longstanding hypertension. A LIFE substudy. Losartan Intervention For Endpoint-Reduction in Hypertension

    DEFF Research Database (Denmark)

    Olsen, M H; Wachtell, K; Hermann, K L

    2001-01-01

    unmedicated patients with essential hypertension and electrocardiographic left ventricular (LV) hypertrophy, we measured maximal workload and oxygen reserve by bicycle test, 24-h ambulatory blood pressure (BP), LV mass index by magnetic resonance imaging (LVMI(MRI), n = 31), LVMI(echo) and systemic vascular...

  8. A serial changes of thallium-201 myocardial images in a patient with nontransmural myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Itoh, Yukiyoshi; Takayama, Yasuo

    1986-01-01

    A 66 year old man had suffered from inferior myocardial infarction one year ago and then suffered from effort angina. Recently rest angina attack frequently occurred and he was admitted because of angina attack refractory to TNG. The patient was diagnosed as broad nontransmural infarction. A serial thallium-201 myocardial imagings at rest and thallium-201 lung uptake imagings were performed and some interesting findings were obtained as followings. Myocardial imagings on 3rd day after admission showed no significant deffect, however EF was 34 %. Immediately after severe ischemic attack marked defect was noted at posterolateral region and ECG showed prominent precordial ST depression without accompanying significant ST change in II, III, aVF. On 3rd day after severe attack under hemodynamically and electrocardiographically stable state posterolateral defect improved, though still persisted. EF was 28 %. On 3rd day postop no marked defects were noted in myocardial imagings, so posterolateral defect at rest after severe ischemic attack was proved to be transient defect. In this case thallium-201 lung uptake was not noted before attack. Immediately after severe attack thallium lung uptake increased and maximal uptake was noted at basal zone of lung, however in chest X-P typical butterfly shadow was noted at upper zone of lung. On 3rd day after severe attack hemodynamics improved and butterfly shadow ceased, though thallium lung uptake increased and noted at upper zone of lung. After operation thallium lung uptake improved. (J.P.N.)

  9. Influence of Respiratory Gating, Image Filtering, and Animal Positioning on High-Resolution Electrocardiography-Gated Murine Cardiac Single-Photon Emission Computed Tomography

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2015-01-01

    Full Text Available Cardiac parameters obtained from single-photon emission computed tomographic (SPECT images can be affected by respiratory motion, image filtering, and animal positioning. We investigated the influence of these factors on ultra-high-resolution murine myocardial perfusion SPECT. Five mice were injected with 99m technetium (99mTc-tetrofosmin, and each was scanned in supine and prone positions in a U-SPECT-II scanner with respiratory and electrocardiographic (ECG gating. ECG-gated SPECT images were created without applying respiratory motion correction or with two different respiratory motion correction strategies. The images were filtered with a range of three-dimensional gaussian kernels, after which end-diastolic volumes (EDVs, end-systolic volumes (ESVs, and left ventricular ejection fractions were calculated. No significant differences in the measured cardiac parameters were detected when any strategy to reduce or correct for respiratory motion was applied, whereas big differences (> 5% in EDV and ESV were found with regard to different positioning of animals. A linear relationship (p < .001 was found between the EDV or ESV and the kernel size of the gaussian filter. In short, respiratory gating did not significantly affect the cardiac parameters of mice obtained with ultra-high-resolution SPECT, whereas the position of the animals and the image filters should be the same in a comparative study with multiple scans to avoid systematic differences in measured cardiac parameters.

  10. An overview of contemporary nuclear cardiology.

    Science.gov (United States)

    Lewin, Howard C; Sciammarella, Maria G; Watters, Thomas A; Alexander, Herbert G

    2004-01-01

    Myocardial perfusion single photon emission computed tomography (SPECT) is a widely utilized noninvasive imaging modality for the diagnosis, prognosis, and risk stratification of coronary artery disease. It is clearly superior to the traditional planar technique in terms of imaging contrast and consequent diagnostic and prognostic yield. The strength of SPECT images is largely derived from the three-dimensional, volumetric nature of its image. Thus, this modality permits three-dimensional assessment and quantitation of the perfused myocardium and functional assessment through electrocardiographic gating of the perfusion images.

  11. Association of Trypanosoma cruzi infection with risk factors and electrocardiographic abnormalities in northeast Mexico

    Science.gov (United States)

    2014-01-01

    Background American trypanosomiasis is a major disease and public health issue, caused by the protozoan parasite Trypanosoma cruzi. The prevalence of T. cruzi has not been fully documented, and there are few reports of this issue in Nuevo Leon. The aim of this study was to update the seroprevalence rate of T. cruzi infection, including an epidemiological analysis of the risk factors associated with this infection and an electrocardiographic (ECG) evaluation of those infected. Methods Sera from 2,688 individuals from 10 municipalities in the state of Nuevo Leon, Mexico, were evaluated using an enzyme-linked immunosorbent assay and an indirect hemagglutination assay. An ECG case–control study was performed in subjects seropositive for T. cruzi and the results were matched by sex and age to seronegative residents of the same localities. A univariate analysis with χ2 and Fisher’s exact tests was used to determine the association between seropositivity and age (years), sex, and ECG changes. A multivariate analysis was then performed to calculate the odd ratios between T. cruzi seropositivity and the risk factors. Results The seropositive rate was 1.93% (52/2,688). In the ECG study, 22.85% (8/35) of the infected individuals exhibited ECG abnormalities. Triatoma gerstaeckeri was the only vector reported. The main risk factors were ceiling construction material (P ≤ 0.0024), domestic animals (P ≤ 0.0001), and living in rural municipalities (P ≤ 0.0025). Conclusions These findings demonstrate a 10-fold higher prevalence of Chagas disease than previously reported (0.2%), which implies a serious public health threat in northeastern Mexico. The epidemiological profile established in this study differs from that found in the rest of Mexico, where human populations live in close proximity to domiciliary triatomines. PMID:24580840

  12. Diagnostic Accuracy of a New Cardiac Electrical Biomarker for Detection of Electrocardiogram Changes Suggestive of Acute Myocardial Ischemic Injury

    Science.gov (United States)

    Schreck, David M; Fishberg, Robert D

    2014-01-01

    Objective A new cardiac “electrical” biomarker (CEB) for detection of 12-lead electrocardiogram (ECG) changes indicative of acute myocardial ischemic injury has been identified. Objective was to test CEB diagnostic accuracy. Methods This is a blinded, observational retrospective case-control, noninferiority study. A total of 508 ECGs obtained from archived digital databases were interpreted by cardiologist and emergency physician (EP) blinded reference standards for presence of acute myocardial ischemic injury. CEB was constructed from three ECG cardiac monitoring leads using nonlinear modeling. Comparative active controls included ST voltage changes (J-point, ST area under curve) and a computerized ECG interpretive algorithm (ECGI). Training set of 141 ECGs identified CEB cutoffs by receiver-operating-characteristic (ROC) analysis. Test set of 367 ECGs was analyzed for validation. Poor-quality ECGs were excluded. Sensitivity, specificity, and negative and positive predictive values were calculated with 95% confidence intervals. Adjudication was performed by consensus. Results CEB demonstrated noninferiority to all active controls by hypothesis testing. CEB adjudication demonstrated 85.3–94.4% sensitivity, 92.5–93.0% specificity, 93.8–98.6% negative predictive value, and 74.6–83.5% positive predictive value. CEB was superior against all active controls in EP analysis, and against ST area under curve and ECGI by cardiologist. Conclusion CEB detects acute myocardial ischemic injury with high diagnostic accuracy. CEB is instantly constructed from three ECG leads on the cardiac monitor and displayed instantly allowing immediate cost-effective identification of patients with acute ischemic injury during cardiac rhythm monitoring. PMID:24118724

  13. Electrocardiographic Findings in Patients With Acute Coronary Syndrome Presenting With Out-of-Hospital Cardiac Arrest.

    Science.gov (United States)

    Sarak, Bradley; Goodman, Shaun G; Brieger, David; Gale, Chris P; Tan, Nigel S; Budaj, Andrzej; Wong, Graham C; Huynh, Thao; Tan, Mary K; Udell, Jacob A; Bagai, Akshay; Fox, Keith A A; Yan, Andrew T

    2018-02-01

    We sought to characterize presenting electrocardiographic findings in patients with acute coronary syndromes (ACSs) and out-of-hospital cardiac arrest (OHCA). In the Global Registry of Acute Coronary Events and Canadian ACS Registry I, we examined presenting and 24- to 48-hour follow-up ECGs (electrocardiogram) of ACS patients who survived to hospital admission, stratified by presentation with OHCA. We assessed the prevalence of ST-segment deviation and bundle branch blocks (assessed by an independent ECG core laboratory) and their association with in-hospital and 6-month mortality among those with OHCA. Of the 12,040 ACS patients, 215 (1.8%) survived to hospital admission after OHCA. Those with OHCA had higher presenting rates of ST-segment elevation, ST-segment depression, T-wave inversion, precordial Q-waves, left bundle branch block (LBBB), and right bundle branch block (RBBB) than those without. Among patients with OHCA, those with ST-segment elevation had significantly lower in-hospital mortality (20.9% vs 33.0%, p = 0.044) and a trend toward lower 6-month mortality (27% vs 39%, p = 0.060) compared with those without ST-segment elevation. Conversely, among OCHA patients, LBBB was associated with significantly higher in-hospital and 6-month mortality rates (58% vs 22%, p presenting ECG resolved by 24 to 48 hours. In conclusion, compared with ACS patients without cardiac arrest, those with OHCA had higher rates of ST-segment elevation, LBBB, and RBBB on admission. Among OHCA patients, ST-segment elevation was associated with lower in-hospital mortality, whereas LBBB was associated with higher in-hospital and 6-month mortality. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Associations of electrocardiographic P-wave characteristics with left atrial function, and diffuse left ventricular fibrosis defined by cardiac magnetic resonance: The PRIMERI Study.

    Science.gov (United States)

    Tiffany Win, Theingi; Ambale Venkatesh, Bharath; Volpe, Gustavo J; Mewton, Nathan; Rizzi, Patricia; Sharma, Ravi K; Strauss, David G; Lima, Joao A; Tereshchenko, Larisa G

    2015-01-01

    Abnormal P-terminal force in lead V1 (PTFV1) is associated with an increased risk of heart failure, stroke, atrial fibrillation, and death. Our goal was to explore associations of left ventricular (LV) diffuse fibrosis with left atrial (LA) function and electrocardiographic (ECG) measures of LA electrical activity. Patients without atrial fibrillation (n = 91; mean age 59.5 years; 61.5% men; 65.9% white) with structural heart disease (spatial QRS-T angle ≥105° and/or Selvester QRS score ≥5 on ECG) but LV ejection fraction >35% underwent clinical evaluation, cardiac magnetic resonance, and resting ECG. LA function indices were obtained by multimodality tissue tracking using 2- and 4-chamber long-axis images. T1 mapping and late gadolinium enhancement were used to assess diffuse LV fibrosis and presence of scar. P-prime in V1 amplitude (PPaV1) and duration (PPdV1), averaged P-wave-duration, PR interval, and P-wave axis were automatically measured using 12 SLTM algorithm. PTFV1 was calculated as a product of PPaV1 and PPdV1. In linear regression after adjustment for demographic characteristics, body mass index, maximum LA volume index, presence of scar, and LV mass index, each decile increase in LV interstitial fibrosis was associated with 0.76 mV*ms increase in negative abnormal PTFV1 (95% confidence interval [CI] -1.42 to -0.09; P = .025), 15.3 ms prolongation of PPdV1 (95% CI 6.9 to 23.8; P = .001) and 5.4 ms prolongation of averaged P-duration (95% CI 0.9-10.0; P = .020). LV fibrosis did not affect LA function. PPaV1 and PTFV1 were associated with an increase in LA volumes and decrease in LA emptying fraction and LA reservoir function. LV interstitial fibrosis is associated with abnormal PTFV1, prolonged PPdV1, and P-duration, but does not affect LA function. Copyright © 2015 Heart Rhythm Society. All rights reserved.

  15. Prognostic value of exercise thallium-201 imaging in patients presenting for evaluation of chest pain

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Guiney, T.E.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Accurate prognostic information is important in determining optimal management of patients presenting for evaluation of chest pain. In this study, the ability of exercise thallium-201 myocardial imaging to predict future cardiac events (cardiovascular death or nonfatal myocardial infarction) was correlated with clinical, coronary and left ventricular angiographic and exercise electrocardiographic data in 139 consecutive, nonsurgically managed patients followed-up over a 3 to 5 year period (mean follow-up, 3.7 +/- 0.9), using a logistic regression analysis. Among patients without prior myocardial infarction (100 of 139), the number of myocardial segments with transient thallium-201 defects was the only statistically significant predictor of future cardiac events when all patient variables were evaluated. Among patients with myocardial infarction before evaluation (39 of 139), angiographic ejection fraction was the only significant predictor of future cardiac events when all variables were considered. This study suggests an approach to evaluate the risk of future cardiac events in patients with possible ischemic heart disease

  16. Electrocardiographic changes of acute lateral wall myocardial infarction: a reappraisal based on scintigraphic localization of the infarct

    International Nuclear Information System (INIS)

    Movahed, A.; Becker, L.C.

    1984-01-01

    To determine how often acute lateral myocardial infarcts may be electrocardiographically silent, a new approach was utilized in which subjects were selected by admission thallium scintigraphy. Thirty-one patients with their first infarction were identified with moderate to severe perfusion defects of the lateral and posterolateral walls, persistent over 7 days and associated with severe wall motion abnormalities. Patients with involvement of the anterior, septal or inferior regions were not included. In nine patients, the perfusion defect extended to the anterolateral wall: all developed ST elevation and Q waves in at least one of the lateral leads (I, aVL or V6) but none showed changes in the inferior leads (II, III or aVF). In the other 22 patients, the perfusion defect was limited to the lateral and posterolateral walls: only 12 showed ST elevations (inferior leads only in 7, lateral leads only in 2, both leads in 3) and only 9 developed Q waves (inferior in all). In 8 of these 22 patients, the infarct was silent in the sense that no ST segment elevation or Q waves were seen, although ST depressions or T wave inversions, or both, in all but one patient were compatible with subendocardial infarction. The results indicate that the standard electrocardiogram is insensitive to changes in the lateral and posterolateral regions. Additional diagnostic studies are needed for proper localization and sizing of acute myocardial infarcts

  17. Association of Age, Sex, Body Size and Ethnicity with Electrocardiographic Values in Community-based Older Asian Adults.

    Science.gov (United States)

    Tan, Eugene S J; Yap, Jonathan; Xu, Chang Fen; Feng, Liang; Nyunt, Shwe Zin; Santhanakrishnan, Rajalakshmi; Chan, Michelle M Y; Seow, Swee Chong; Ching, Chi Keong; Yeo, Khung Keong; Richards, A Mark; Ng, Tze Pin; Lim, Toon Wei; Lam, Carolyn S P

    2016-07-01

    Existing electrocardiographic (ECG) reference values were derived in middle-aged Caucasian adults. We aimed to assess the association of age, sex, body size and ethnicity on ECG parameters in a multi-ethnic Asian population. Resting 12-lead ECG and anthropometric measurements were performed in a community-based cohort of 3777 older Asians (age 64.7±9.1 years, 1467 men, 88.8% Chinese, 7.7% Malay, 3.5% Indian, body mass index [BMI] 24.0±3.9kg/m(2)). Men had longer PR interval, wider QRS, shorter QTc interval and taller SV3. In both sexes, older age was associated with longer PR interval, wider QRS, larger R aVL and more leftward QRS axis, while higher BMI was associated with longer PR interval, wider QRS, larger RaVL and more negative QRS axis. There were significant inter-ethnic differences in QRS duration among men, as well as in PR and QTc intervals among women (all adjusted p<0.05). Findings were similar in a healthy subset of 1158 adults (age 61.2±9.1 years, 365 men) without cardiovascular risk factors. These first community-based ECG data in multi-ethnic older Asians highlight the independent effects of age, sex, body size and ethnicity on ECG parameters. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  18. Influence of Age and Aerobic Fitness on the Multifractal Characteristics of Electrocardiographic RR Time-Series

    Directory of Open Access Journals (Sweden)

    Michael James Lewis

    2013-05-01

    Full Text Available Multifractal properties of electrocardiographic inter-beat (RR time-series offer insight into its long-term correlation structure, independently of RR variability. Here we quantify multifractal characteristics of RR data during 24-hour diurnal-nocturnal activity in healthy participants. We tested the hypotheses that (1 age, gender and aerobic fitness influence RR multifractal properties, and that (2 these are influenced by circadian variation.Seventy adults (39 males aged 19-58 years and of various fitness levels were monitored using 24-hour ECG. Participants were dichotomised by median age and fitness for sub-group analysis. Gender and fitness were independent of age (p=0.1, p>0.5. Younger/older group ages were substantially different (p<0.0005 and were independent of gender and fitness. Multifractality was quantified using the probability spectrum of Hölder exponents (h, from which modal h (h* and the full-width and half-widths at half-maximum measures (FWHM, HWHM+ and HWHM- were derived. FWHM decreased (p=0.004 and h* increased (p=0.011 in older people, indicating diminished long-range RR correlations and weaker anti-persistent behavior. Anti-persistent correlation (h* was strongest in the youngest/fittest individuals and weakest in the oldest/least fit individuals (p=0.015. Long-range correlation (HWHM+/FWHM was strongest in the fittest males and weakest in the least fit females (p=0.007-0.033.Multifractal RR characteristics in our healthy participants showed strong age-dependence with diminished long-range anti-persistent correlation in older people. Circadian variation of these characteristics was influenced by fitness and gender: fitter males and females of all ages had the greatest degree of multifractality or long-range order. Multifractal characterisation appears to be a useful method for exploring the physiological basis of long-term correlation structure in RR time-series as well as the benefits thereon of physical fitness training.

  19. Electrocardiographic reference values and configuration of electrocardiogram waves recorded in Black Bengal goats of different age groups.

    Science.gov (United States)

    Pradhan, Ranjeeta Rashmee; Mahapatra, Ambika Prasad Khadanga; Mohapatra, Swagat; Jyotiranjan, Tushar; Kundu, Akshaya Kumar

    2017-09-01

    A study on age-related electrocardiographic (ECG) changes was conducted on 20 apparently healthy Black Bengal goats with no history of cardiac disorders during 2015-2016. The goats selected for the study belonged to four different age groups; Group 1: Goats up to 6 months of age, Group 2: Above 6 months and below 1 year of age, Group 3: Above 1 year and below 2 years of age, and Group 4: Above 2 years of age. The ECG was recorded with the animals in standing position using a 12-lead standard ECG recorder (Model-Cardiart-108 MK VII, manufactured by BPL, India). The paper speed was set to 25 mm/s with the sensitivity of the machine was adjusted at 1 (1 cm=mV). The ECG parameters were compared within different age groups, and the data were analyzed statistically using SPSS 16.0 taking a significant level of 95% (page groups. In bipolar limb lead-II, the amplitude of T-wave, RR interval, ST segment, TP segment, and heart rate was a significant difference among some age groups. Lead-III presented significant difference among age groups in different parameters such as QRS complex duration, T-wave duration, RR interval, ST segment, TP segment, and heart rate. The study concluded that there is a significant variation in the ECG parameters both in terms of values and configuration of ECG waves when age is taken into consideration. The results of the study might be used as a reference value for field veterinarians.

  20. Maximal exercise electrocardiographic responses and coronary heart disease mortality among men with metabolic syndrome.

    Science.gov (United States)

    Lyerly, G William; Sui, Xuemei; Church, Timothy S; Lavie, Carl J; Hand, Gregory A; Blair, Steven N

    2010-03-01

    To examine the association between abnormal exercise electrocardiographic (E-ECG) test results and mortality (all-cause and that resulting from coronary heart disease [CHD] or cardiovascular disease [CVD]) in a large population of asymptomatic men with metabolic syndrome (MetS). A total of 9191 men (mean age, 46.9 years) met the criteria of having MetS. All completed a maximal E-ECG treadmill test (May 14, 1979, through April 9, 2001) and were without a previous CVD event or diabetes at baseline. Main outcomes were all-cause mortality, mortality due to CHD, and mortality due to CVD. Cox regression analysis was used to quantify the mortality risk according to E-ECG responses. During a follow-up of 14 years, 633 deaths (242 CVD and 150 CHD) were identified. Mortality rates and hazard ratios (HRs) across E-ECG responses were the following: for all-cause mortality: HR, 1.36; 95% confidence interval (CI), 1.09-1.70 for equivocal responses and HR, 1.41; 95% CI, 1.12-1.77 for abnormal responses (P(trend)<.001); for mortality due to CVD: HR, 1.29; 95% CI, 0.88-1.88 for equivocal responses and HR, 2.04; 95% CI, 1.46-2.84 for abnormal responses (P(trend)<.001); and for mortality due to CHD: HR, 1.62; 95% CI, 1.02-2.56 for equivocal responses and HR, 2.45; 95% CI, 1.62-3.69 for abnormal responses (P(trend)<.001). A positive gradient for CHD, CVD, and all-cause mortality rates across E-ECG categories within 3, 4, or 5 MetS components was observed (P<.001 for all). Among men with MetS, an abnormal E-ECG response was associated with higher risk of all-cause, CVD, and CHD mortality. These findings underscore the importance of E-ECG tests to identify men with MetS who are at risk of dying.

  1. Simultaneous low level treadmill exercise and intravenous dipyridamole stress thallium imaging

    International Nuclear Information System (INIS)

    Casale, P.N.; Guiney, T.E.; Strauss, H.W.; Boucher, C.A.

    1988-01-01

    Intravenous dipyridamole-thallium imaging unmasks ischemia in patients unable to exercise adequately. However, some of these patients can perform limited exercise, which, if added, may provide useful information. Treadmill exercise combined with dipyridamole-thallium imaging was performed in 100 patients and results compared with those of 100 other blindly age- and sex-matched patients who received dipyridamole alone. Exercise began after completion of the dipyridamole infusion. Mean +/- 1 standard deviation peak heart rate (109 +/- 19 vs 83 +/- 12 beats/min, p less than 0.0001) and peak systolic and diastolic blood pressure (146 +/- 28/77 +/- 14 vs 125 +/- 24/68 +/- 11 mm Hg, p less than 0.0001) were higher in the exercise group compared with the nonexercise group. There was no difference in the occurrence of chest pain, but more patients in the exercise group developed ST-segment depression (26 vs 12%, p less than 0.0001). The exercise group had fewer noncardiac side effects (4 vs 12%, p less than 0.01) and a higher target (heart) to background (liver) count ratio (2.1 +/- 0.7 vs 1.2 +/- 0.3; p less than 0.01), due to fewer liver counts. There were no deaths, myocardial infarctions or sustained arrhythmias in either group. Combined treadmill exercise and dipyridamole testing is safe, associated with fewer noncardiac side effects, a higher target to background ratio and a higher incidence of clinical electrocardiographic ischemia than dipyridamole alone. Therefore, it is recommended whenever possible

  2. Trypanosoma cruzi in dogs: electrocardiographic and echocardiographic evaluation, in Malinalco, State of Mexico

    Directory of Open Access Journals (Sweden)

    González-Vieyra SD

    2011-12-01

    Full Text Available Sandra Díaz González-Vieyra1, Ninfa Ramírez-Durán2, Ángel H Sandoval-Trujillo3, Juan C Vázquez-Chagoyán1, Humberto G Monroy-Salazar1, Alberto Barbabosa-Pliego11Research Center of Advanced Studies in Animal Health, Veterinary Husbandry School, 2Medical and Ambiental Microbiology, Research Center of Advanced Studies in Health Science, School of Medicine, Autonomous University of the State of Mexico, Toluca, Mexico; 3Department of Biological Systems, Metropolitan Autonomous University, Xochimilco, Mexico City, MexicoAbstract: Chagas disease caused by Trypanosoma cruzi is an important public health problem in Latin America. Dogs are considered a risk factor for human Chagas disease, a sentinel for T. cruzi infection in endemic regions and an animal model to study pathological aspects of the disease. The potential use of dogs as indicators of human cardiac pathogenicity of local T. cruzi strains has been studied insufficiently. We studied electrocardiographic (EKG and echocardiographic (ECG alteration frequencies observed in an open population of dogs in Malinalco, Mexico, and determined if such frequencies were statistically associated with T. cruzi infection in dogs. Animals (n = 139 were clinically examined and owners were asked to answer a questionnaire about dogs’ living conditions. Two commercial serological tests (IHA, ELISA were conducted to detect anti-T. cruzi serum antibodies. Significant differences between seropositive and seronegative animals in cardiomyopathic frequencies were detected through EKG and ECG (P < 0.05. Thirty dogs (21.58% were serologically positive to anti-T. cruzi antibodies (to ELISA and IHA assays, of which nine (30% had EKG and/or ECG alterations. From the remaining 104 (78.42% seronegative animals, five (4.5% had EKG and/or ECG abnormalities. Our data support the hypothesis that most EKG and ECG alterations found in dogs from Malinalco could be associated with T. cruzi infection. Considering the dog as a

  3. Comparison of exercise perfusion and ventricular function imaging: an analysis of factors affecting the diagnostic accuracy of each technique

    International Nuclear Information System (INIS)

    Osbakken, M.D.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1984-01-01

    Exercise thallium-201 perfusion scans and gated equilibrium blood pool scans were performed in 120 catheterized patients with a chest pain syndrome. Eighty-six patients had coronary artery disease and 34 patients did not. The effects of gender, propranolol, exercise level, exercise ischemia, history of typical angina, history of previous myocardial infarction, electrocardiographic Q waves, number of diseases vessels and extent of coronary artery obstruction on diagnostic accuracy were evaluated. Thallium scans and anginal history were less sensitive for detecting coronary disease in women (men: thallium 79%; angina 77%; women: 54 and 46%, respectively; p less than 0.05). Exercise level did not significantly affect the diagnostic accuracy of either scan. Thallium and gated scans were both highly sensitive (95%) in detecting disease in 20 patients with a prior myocardial infarction, angina and a positive electrocardiogram. The sensitivity of the thallium scan significantly decreased as the number of diseased vessels decreased. Both thallium and gated scans were less frequently positive in patients with atypical angina or no Q waves, but were not significantly influenced by electrocardiographic ischemia. The sensitivity and specificity of both scans were low in 57 patients with the combination of atypical angina, no history of infarction and equivocal stress electrocardiogram thallium. When stress thallium scan evaluation included the electrocardiogram and thallium scan interpretation, the diagnostic accuracy was 81%. When all the information from gated scans (wall motion, ejection fraction, pulmonary blood volume) was combined for final gated scan evaluation, the diagnostic accuracy was 83%. When electrocardiographic data were added to all three gated scan variables, diagnostic accuracy was 77%

  4. The effect of intramuscular administration of medroxy progesterone acetate (MPA on electrocardiographic alterations of female dogs

    Directory of Open Access Journals (Sweden)

    M Neshat Gharamaleky

    2010-11-01

    Full Text Available Progestins are useful for hormonal prevention of pregnancy in humans and animals. Progestrone and medroxy progestrone acetate are used for treatment of premenopausal syndrome and decreasing complications of estrogen therapy after menopause. Prescription of progesterone in dogs is usually done to control or delay estrus. If this drug is used at anestrous it will inhibit the gonadotropin excretion beyond the basic level and it will prevent cycle from happening again in proestrus or at the beginning of estrus progesterone will prevent ovulation. Use of progesterone is not totally safe in bitches. It can cause several problems such as cystic endometrial hyperplasia and pyrometera. In this study the effects of medroxy progestrone acetat (MPA on electrocardiographic changes are evaluated. After nutritional and environmental uniformity and other evaluations, the animals were divided into two groups with six bitches in each group. MPA was used at 10 mg/kg for the first group and 20 mg/kg for the second group. An ECG was recorded from the first group in time zero. MPA was injected intramuscularly and immediately after ECG recording and the time of injection was noted. Another ECG was recorded 0.5 and 2 hours after injection. The same process was repeated for the second group. It was observed that MPA at 20 mg/kg increased the heart rate and consequently PR interval and RR interval were decreased significantly in normal range. Also administration of drug at 10 mg/kg decreased the heart rate and increased PR interval, QT interval and RR interval significantly in normal range. It is probable that these observations are the result of MPAs dose dependent vasodilatory nature that induces the heart to exhibit compensative reactions such as increasing heart rate.

  5. N-terminal pro brain natriuretic peptide in arterial hypertension--a marker for left ventricular dimensions and prognosis

    DEFF Research Database (Denmark)

    Hildebrandt, Per; Boesen, Mikael; Olsen, Michael

    2004-01-01

    In arterial hypertension risk factor evaluation, including LV mass measurements, and risk stratification using risk charts or programs, is generally recommended. In heart failure NT-proBNP has been shown to be a marker of LV dimensions and of prognosis. If the same diagnostic and prognostic value...... is present in arterial hypertension, risk factor evaluation would be easier. In 36 patients with arterial hypertension, electrocardiographic LV hypertrophy and preserved left ventricular function, NT-proBNP was eight-fold higher than in healthy subjects. The log NT-proBNP correlated with LV mass index (R=0.......47, P=0.0002) measured by magnetic resonance imaging. In other subjects with arterial hypertension a significant but weak correlation to diastolic properties has been demonstrated. As for prognosis, a recent study in patients with hypertension, electrocardiographic left ventricular hypertrophy...

  6. Electrocardiographic manifestations of inherited heart diseases – a sports cardiologist’s point ofview. Part 2. Ion channel diseases

    Directory of Open Access Journals (Sweden)

    Zbigniew Krenc

    2015-09-01

    Full Text Available Physical activity is associated with an increased risk of sudden death for individuals with an undiagnosed cardiovascular disease. Medical evaluations, including a resting electrocardiogram, conducted before and during physical training, enable the identification of still asymptomatic athletes with life-threatening heart diseases and help to protect them from sudden cardiac death. The incidence of sudden cardiac death is estimated at two cases for each 100,000 young athletes per year and it is 2–4 times higher when compared with non-athletes. The most common causes of sudden cardiac death in athletes younger than 35 are cardiomyopathies: hypertrophic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy. Three to four per cent of young athletes who die suddenly have no evidence of a structural heart disease, and the cause of their cardiac arrest is primarily electrical heart diseases, such as inherited cardiac ion channel defects (channelopathies, including long and short QT syndromes, Brugada syndrome, and catecholaminergic polymorphic ventricular tachycardia The clinical courses of all these channelopathies are highly varied. They can be asymptomatic. In certain cases, episodic syncope or aborted cardiac arrest can occur. Sudden cardiac death, especially during physical exercise, can be the first sign. The aim of this article was to provide some information helpful in the recognition of electrocardiographic changes in genetic ion channel diseases, especially in the context of the prevention of sudden cardiac events in young athletes.

  7. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    Science.gov (United States)

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  8. Electrocardiographic study on geriatric dogs undergoing general anesthesia with isoflurane Estudo eletrocardiográfico em cães geriátricos submetidos à anestesia geral com isofluorano

    Directory of Open Access Journals (Sweden)

    Andreza Conti-Patara

    2009-04-01

    Full Text Available The purpose of this study was to clarify the degree of influence of anesthetic agents commonly used during anesthesia on the heart conduction systems of geriatric dogs, with or without the presence of electrocardiographic changes in the pre-anesthetic electrocardiogram and also to determine the possible causes of ST-segment and T-wave changes during anesthesia, by monitoring ventilation and oxygenation. 36 geriatric dogs were evaluated. In addition to electrocardiographic evaluation, the pre-anesthetic study included serum levels of urea, creatinine, total protein, albumin and electrolytes. The pre-anesthetic medication consisted of acepromazine (0.05mg kg-1 in association with meperidine (3.0mg kg-1 by IM injection. Anesthesia was induced with propofol (3.0 to 5.0mg kg-1 by IV injection and maintained with isoflurane in 100% oxygen. During the anesthesia, the animals were monitored by continued computerized electrocardiogram. Systemic blood pressure, heart rate, respiratory rate, end-tidal carbon dioxide, partial pressure of carbon dioxide in arterial blood, arterial oxygen saturation, partial pressure of arterial oxygen and oxygen saturation of hemoglobin were closely monitored. During maintenance anesthesia, normal sinus rhythm was more common (78%. ST-segment and T-wave changes during the anesthetic procedure were quite common and were related to hypoventilation. The use of isoflurane did not result in arrhythmia, being therefore a good choice for this type of animal; Electrocardiographic findings of ST-segment and T-wave changes during the maintenance anesthesia were evident in animals with hypercapnia, a disorder that should be promptly corrected with assisted or controlled ventilation to prevent complicated arrhythmias.Os objetivos deste estudo foram esclarecer a influência dos agentes anestésicos comumente utilizados durante a anestesia no sistema de condução cardíaco em cães idosos, com ou sem alterações eletrocardiográficas pr

  9. Comparison of myocardial fatty acid metabolism with left ventricular function and perfusion in cardiomyopathies. By 123I-BMIPP SPECT and 99mTc-tetrofosmin electrocardiographically gated SPECT

    International Nuclear Information System (INIS)

    Zhao, Chunlei; Shuke, Noriyuki; Okizaki, Atsutaka

    2003-01-01

    The objective of this study was to investigate myocardial fatty acid metabolism and its relationship with left ventricular (LV) function and perfusion in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM). Thirty-nine patients with cardiomyopathies (58±14 y), comprising 15 DCM and 24 HCM, and 9 age-matched healthy controls were studied with 123 I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and 99m Tc-tetrofosmin (TF) electrocardiographically gated SPECT. As parameters of myocardial fatty acid metabolism, the heart-to-mediastinum ratio (H/M) and global washout of BMIPP were calculated from early and delayed planar images, while regional BMIPP uptake and washout were calculated from SPECT. In TF study, the H/M (H/M-TF) and LV ejection fraction (LVEF) were calculated as global parameters of perfusion and function, while regional TF uptake and wall thickening index were calculated as regional parameters of perfusion and function using the Quantitative Gated SPECT software. The differences in the parameters and the correlations between the parameters from the 2 studies were investigated by one-way ANOVA and multiple linear regression analysis. BMIPP uptake was decreased (p 0.05), but showed a significant correlation with H/M-TF (p 0.05) but had a significant correlation with regional perfusion (p<0.0001) in DCM. In HCM, regional BMIPP parameters showed significant multiple linear correlations with both regional function (p<0.005) and perfusion (p<0.0001). According to the partial correlation coefficients, delayed regional BMIPP uptake was the most significant factor for predicting regional function in HCM, while early regional BMIPP uptake was the only or the most significant factor for predicting regional perfusion in DCM and HCM, respectively. In DCM, BMIPP uptake and washout could not reflect LV function. In HCM, regional delayed BMIPP uptake might be useful for evaluating regional function. In DCM and HCM, early BMIPP uptake might be

  10. An electrocardiographic, molecular and biochemical approach to explore the cardioprotective effect of vasopressin and milrinone against phosphide toxicity in rats.

    Science.gov (United States)

    Jafari, Abbas; Baghaei, Amir; Solgi, Reza; Baeeri, Maryam; Chamanara, Mohsen; Hassani, Shokoufeh; Gholami, Mahdi; Ostad, Seyed Nasser; Sharifzadeh, Moahmmad; Abdollahi, Mohammad

    2015-06-01

    The present study was conducted to identify the protective effect of vasopressin (AVP) and milrinone on cardiovascular function, mitochondrial complex activities, cellular ATP reserve, oxidative stress, and apoptosis in rats poisoned by aluminum phosphide (AlP). Rats were divided into five groups (n = 12) including control, AlP (12.5 mg/kg), AlP + AVP (2.0 Units/kg), AlP + milrinone (0.25 mg/kg) and AlP + AVP + milrinone. After treatment, the animals were connected to an electronic cardiovascular monitoring device to monitor electrocardiographic (ECG) parameter. Finally, oxidative stress biomarkers, mitochondrial complex activities, ADP/ATP ratio and apoptosis were evaluated on the heart tissues. Results indicated that AlP administration induced ECG abnormalities along with a decline in blood pressure and heart rate. AVP and milrinone significantly ameliorated these changes in all treated groups. Considerable protective effects on oxidative stress biomarkers, complex IV activity, ADP/ATP ratio and caspase-3 and -9 activities in treated groups were also found. These findings were supported by flow cytometry assay of cardiomyocytes. In conclusion, administration of AVP and milrinone, not only improve cardiovascular functions in AlP poisoned rats in the short time, but after a long time can also restore mitochondrial function and ATP level and reduce the oxidative damage, which prevent cardiomyocytes from entering the apoptotic phase. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Evaluation of left ventricular function using electrocardiographically gated myocardial SPECT with (123)I-labeled fatty acid analog.

    Science.gov (United States)

    Nanasato, M; Ando, A; Isobe, S; Nonokawa, M; Hirayama, H; Tsuboi, N; Ito, T; Hirai, M; Yokota, M; Saito, H

    2001-12-01

    Electrocardiographically (ECG) gated myocardial SPECT with (99m)Tc-tetrofosmin has been used widely to assess left ventricular (LV) function. However, the accuracy of variables using ECG gated myocardial SPECT with beta-methyl-p-(123)I-iodophenylpentadecanoic acid (BMIPP) has not been well defined. Thirty-six patients (29 men, 7 women; mean age, 61.6 +/- 15.6 y) with ischemic heart disease underwent ECG gated myocardial SPECT with (123)I-BMIPP and with (99m)Tc-tetrofosmin and left ventriculography (LVG) within 1 wk. LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), and LV end-systolic volume (LVESV) were determined on gated SPECT using commercially available software for automatic data analysis. These volume-related items on LVG were calculated with an area-length method and were estimated by 2 independent observers to evaluate interobserver validity. The regional wall motion with these methods was assessed visually. LVEF was 41.1% +/- 12.5% on gated SPECT with (123)I-BMIPP, 44.5% +/- 13.1% on gated SPECT with (99m)Tc-tetrofosmin, and 46.0% +/- 12.7% on LVG. Global LV function and regional wall motion between both gated SPECT procedures had excellent correlation (LVEF, r = 0.943; LVEDV, r = 0.934; LVESV, r = 0.952; regional wall motion, kappa = 0.92). However, the correlations of global LV function and regional wall motion between each gated SPECT and LVG were significantly lower. Gated SPECT with (123)I-BMIPP showed the same interobserver validity as gated SPECT with (99m)Tc-tetrofosmin. Gated SPECT with (123)I-BMIPP provides high accuracy with regard to LV function and is sufficiently applicable for use in clinical SPECT. This technique can simultaneously reveal myocardial fatty acid metabolism and LV function, which may be useful to evaluate various cardiac diseases.

  12. Temporal and spatial performance of vector velocity imaging in the human fetal heart.

    Science.gov (United States)

    Matsui, H; Germanakis, I; Kulinskaya, E; Gardiner, H M

    2011-02-01

    To assess the spatial and temporal performance of fetal myocardial speckle tracking, using high-frame-rate (HFR) storing and Lagrangian strain analysis. Dummy electrocardiographic signaling permitted DICOM HFR in 124 normal fetuses and paired low-frame-rate (LFR) video storing at 25 Hz in 93 of them. Vector velocity imaging (VVI) tracking co-ordinates were used to compare time and spatial domain measures. We compared tracking success, Lagrangian strain, peak diastolic velocity and positive strain rate values in HFR vs. LFR video storing. Further comparisons within an HFR subset included Lagrangian vs. natural strain, VVI vs. M-mode annular displacement, and VVI vs. pulsed-wave tissue Doppler imaging (TDI) peak velocities. HFR (average 79.4 Hz) tracking was more successful than LFR (86 vs. 76%, P = 0.024). Lagrangian and natural HFR strain correlated highly (left ventricle (LV): r = 0.883, P < 0.001; right ventricle (RV): r = 0.792, P < 0.001) but natural strain gave 20% lower values, suggesting reduced reliability of measurement. Lagrangian HFR strain was similar in LV and RV and decreased with gestation (P = 0.015 and P < 0.001, respectively). LV Lagrangian LFR strain was significantly lower than the values for the RV (P < 0.001) and those using paired LV-HFR recordings (P = 0.007). Annular displacement methods correlated highly (LV = 1.046, r = 0.90, P < 0.001; RV = 1.170, r = 0.88, P < 0.001). Early diastolic waves were visible in 95% of TDI, but in only 26% of HFR and 0% of LFR recordings, and HFR-VVI velocities were significantly lower than those for TDI (P < 0.001). Doppler estimation of velocities remains superior to VVI but image gating and use of original co-ordinates should improve offline VVI assessment of fetal myocardial function. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  13. Safety of intravenous dipyridamole thallium myocardial perfusion imaging: experience in 435 patients

    International Nuclear Information System (INIS)

    Dubrey, S.W.; Noble, M.I.M.; Jewkes, R.F.; Bomanji, J.B.

    1993-01-01

    Dipyridamole stress 201 T1 scintigraphy is widely used in the investigation of myocardial ischaemia. We report our experience of adverse effects observed during this diagnostic procedure. A prospective study was undertaken of 435 consecutive patients referred to two nuclear medicine departments for assessment of myocardial perfusion. Patients were monitored prior to and following the infusion of dipyridamole. All symptomatic, haemodynamic and electrocardiographic changes were documented. No deaths occurred in this series. Adverse events were observed in 174 (40%) patients. Of these, three patients experienced 'major' adverse events (0.6%) requiring hospitalization (myocardial infarction = 1; chest pain = 1; simple partial seizure = 1). 'Moderate' adverse events occurred in 39 (8.9%) patients and required intravenous aminophylline to reverse effects (ST segment abnormalities = 26; nausea = 7; headache = 3; chest pain = 2; bronchospasm = 1; protracted vomiting = 1; diarrhoea = 1). 'Minor' adverse events were experienced by 132 (30.3%) patients and did not require aminophylline. Sixty per cent of our patients experienced no ill effects from dipyridamole given as an exercise substitute in conjunction with 201 T1 imaging. The rest had symptoms which were mostly mild, although a few patients found the experience unpleasant. Only one patient experienced a life-threatening episode. (Author)

  14. Electrophysiologic profile and results of invasive risk stratification in asymptomatic children and adolescents with the Wolff-Parkinson-White electrocardiographic pattern.

    Science.gov (United States)

    Kubuš, Peter; Vít, Pavel; Gebauer, Roman A; Materna, Ondřej; Janoušek, Jan

    2014-04-01

    Data on the results and clinical effect of an invasive risk stratification strategy in asymptomatic young patients with the Wolff-Parkinson-White electrocardiographic pattern are scarce. Eighty-five consecutive patients agedWolff-Parkinson-White pattern and persistent preexcitation at maximum exercise undergoing invasive risk stratification were retrospectively studied. Adverse accessory pathway (AP) properties were defined according to currently consented criteria as any of the following: shortest preexcited RR interval during atrial fibrillation/rapid atrial pacing≤250 ms (or antegrade effective refractory period≤250 ms if shortest preexcited RR interval was not available) or inducible atrioventricular re-entrant tachycardia. Age at evaluation was median 14.9 years. Eighty-two patients had a structurally normal heart and 3 had hypertrophic cardiomyopathy. A single manifest AP was present in 80, 1 manifest and 1 concealed AP in 4, and 2 manifest APs in 1 patient. Adverse AP properties were present in 32 of 85 patients (37.6%) at baseline and in additional 16 of 44 (36.4%) after isoproterenol. Ablation was performed in 41 of these 48 patients. Ablation was deferred in the remaining 7 for pathway proximity to the atrioventricular node. In addition, 18 of the low-risk patients were ablated based on patient/parental decision. Adverse AP properties at baseline were exhibited by 37.6% of the evaluated patients with an asymptomatic Wolff-Parkinson-White preexcitation persisting at peak exercise. Isoproterenol challenge yielded additional 36.4% of those tested at higher risk. Ablation was performed in a total of 69.4% of patients subjected to invasive risk stratification.

  15. Electrocardiographic Screening for Prolonged QT Interval to Reduce Sudden Cardiac Death in Psychiatric Patients: A Cost-Effectiveness Analysis.

    Directory of Open Access Journals (Sweden)

    Antoine Poncet

    Full Text Available Sudden cardiac death is a leading cause of mortality in psychiatric patients. Long QT (LQT is common in this population and predisposes to Torsades-de-Pointes (TdP and subsequent mortality.To estimate the cost-effectiveness of electrocardiographic screening to detect LQT in psychiatric inpatients.We built a decision analytic model based on a decision tree to evaluate the cost-effectiveness and utility of LQT screening from a health care perspective. LQT proportion parameters were derived from an in-hospital cross-sectional study. We performed experts' elicitation to estimate the risk of TdP, given extent of QT prolongation. A TdP reduction of 65% after LQT detection was based on positive drug dechallenge rate and through adequate treatment and electrolyte adjustments. The base-case model uncertainty was assessed with one-way and probabilistic sensitivity analyses. Finally, the TdP related mortality and TdP avoidance parameters were varied in a two-way sensitivity analysis to assess their effect on the Incremental Cost-Effectiveness Ratio (ICER.Costs, Quality Ajusted Life Year (QALY, ICER, and probability of cost effectiveness thresholds ($ 10,000, $25,000, and $50,000 per QALY.In the base-case scenario, the numbers of patients needed to screen were 1128 and 2817 to avoid one TdP and one death, respectively. The ICER of systematic ECG screening was $8644 (95%CI, 3144-82 498 per QALY. The probability of cost-effectiveness was 96% at a willingness-to-pay of $50,000 for one QALY. In sensitivity analyses, results were sensitive to the case-fatality of TdP episodes and to the TdP reduction following the diagnosis of LQT.In psychiatric hospitals, performing systematic ECG screening at admission help reduce the number of sudden cardiac deaths in a cost-effective fashion.

  16. Electrocardiographic and blood pressure effects of energy drinks and Panax ginseng in healthy volunteers: A randomized clinical trial.

    Science.gov (United States)

    Shah, Sachin A; Occiano, Andrew; Nguyen, Tinh An; Chan, Amanda; Sky, Joseph C; Bhattacharyya, Mouchumi; O'Dell, Kate M; Shek, Allen; Nguyen, Nancy N

    2016-09-01

    Energy drink usage has been linked to emergency room visits and deaths. The objective of the study is to assess the electrocardiographic and blood pressure effects of energy drinks, Panax ginseng and placebo in healthy individuals. This was a randomized, double blinded, placebo controlled, crossover study. Young healthy volunteers with no comorbid conditions consumed 32oz of an energy drink, control drink with 800mg of Panax ginseng or matching placebo-control drink over 45min. Primary endpoints were QTc interval and systolic blood pressure. Secondary endpoints included QT interval, PR interval, QRS duration, heart rate, and diastolic blood pressure. All endpoints were assessed at baseline, 1, 2, 3.5, and 5.5h. A significant increase in QTc interval 2h post energy drink consumption was evident when compared to placebo (3.37±10.7ms and -3.19±11.8ms respectively; p=0.030). Similarly, systolic blood pressure 2h post energy drink consumption increased when compared to placebo (2.00±6.37mmHg and -2.67±5.83mmHg respectively; p=0.014). The PR interval significantly reduced over a 2h period post energy drink use in a clinically non-meaningful manner. Heart rate at 2h was not significantly higher in the energy drink group when compared to others. The QT interval, QRS interval and diastolic blood pressure were not impacted at any time point. Certain energy drinks consumed at a high volume significantly increase the QTc interval and systolic blood pressure by over 6ms and 4mmHg respectively. Panax ginseng does not have a significant impact on ECG or blood pressure parameters. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. Apical ballooning with mid-ventricular obstruction: the many faces of Takotsubo cardiomyopathy

    Science.gov (United States)

    Spadotto, Veronica; Elmaghawry, Mohamed; Zorzi, Alessandro; Migliore, Federico; Marra, Martina Perazzolo

    2013-01-01

    Takotsubo cardiomyopathy (TTC) is a transient left ventricular dysfunction due to akinesia of the left-ventricular (LV) mid-apical segments (apical ballooning), which can cause severe reduction in LV systolic function. The typical clinical picture of TTC include chest pain, electrocardiographic changes consisting of mild ST-segment elevation followed by diffuse deep T-wave inversion, QTc interval prolongation and mild troponin release in the absence of significant coronary stenoses. The syndrome often affects post-menopausal women and is triggered by sympathetic overstimulation, like intense physical or emotional stress, so that it is called the “broken heart syndrome”. Although left-ventricular systolic dysfunction usually fully recovers within few days, heart failure can still complicate the early phase. We report a case of stress-induced cardiomyopathy that had full recovery after 4 weeks of follow up. The main electrocardiographic, angiographic and imaging features are discussed. PMID:24689016

  18. Mobile, Cloud, and Big Data Computing: Contributions, Challenges, and New Directions in Telecardiology

    OpenAIRE

    Hsieh, Jui-Chien; Li, Ai-Hsien; Yang, Chung-Chi

    2013-01-01

    Many studies have indicated that computing technology can enable off-site cardiologists to read patients’ electrocardiograph (ECG), echocardiography (ECHO), and relevant images via smart phones during pre-hospital, in-hospital, and post-hospital teleconsultation, which not only identifies emergency cases in need of immediate treatment, but also prevents the unnecessary re-hospitalizations. Meanwhile, several studies have combined cloud computing and mobile computing to facilitate better stora...

  19. VLSI in medicine

    CERN Document Server

    Einspruch, Norman G

    1989-01-01

    VLSI Electronics Microstructure Science, Volume 17: VLSI in Medicine deals with the more important applications of VLSI in medical devices and instruments.This volume is comprised of 11 chapters. It begins with an article about medical electronics. The following three chapters cover diagnostic imaging, focusing on such medical devices as magnetic resonance imaging, neurometric analyzer, and ultrasound. Chapters 5, 6, and 7 present the impact of VLSI in cardiology. The electrocardiograph, implantable cardiac pacemaker, and the use of VLSI in Holter monitoring are detailed in these chapters. The

  20. Distrofia muscular de Duchenne: análise eletrocardiográfica de 131 pacientes Distrofia muscular de duchenne: análisis electrocardiográfica de 131 pacientes Duchenne muscular dystrophy: electrocardiographic analysis of 131 patients

    Directory of Open Access Journals (Sweden)

    Maria Auxiliadora Bonfim Santos

    2010-05-01

    , hecho que lo convierte en un examen útil en el diagnóstico de la lesión cardíaca en esta patología. OBJETIVO: Evaluar las alteraciones electrocardiográficas en pacientes portadores de DMD, correlacionándolas con la edad de la población estudiada. MÉTODOS: Se analizaron los ECG de 131 pacientes con diagnóstico de DMD. Se evaluaron diversas variables electrocardiográficas, y los pacientes fueron separados en dos grupos: aquellos con y sin alteraciones, por variable estudiada. Se hizo la correlación de estos dos grupos con la edad de los pacientes. Se utilizaron los criterios de Garson para establecer los parámetros electrocardiográficos de normalidad. RESULTADOS: El ECG estaba anormal en un 78,6% de los pacientes. Todos presentaban ritmo sinusal. Fueron los que siguen a continuación los porcentuales encontrados para las principales variables estudiadas: PR corto = 18,3%, ondas R anormales en V1 = 29,7%, ondas Q anormales en V6 = 21,3%, alteraciones de la repolarización ventricular = 54,9%, ondas QS anormales en paredes inferior y/o lateral alta = 37,4%, disturbios de conducción por la rama derecha = 55,7%, intervalo QTc prolongado = 35,8% y ensanchamiento del QRS = 23,6%. La prueba t no pareado se utilizó para establecerse la correlación de la edad con las variables electrocardiográficas estudiadas en los dos grupos, y solamente la variable alteración de la repolarización mostró diferencia estadísticamente significativa. CONCLUSIÓN: Las alteraciones electrocardiográficas en la DMD son frecuentes, revelando compromiso cardiaco precoz. Solamente la variable alteración de la repolarización ventricular fue más frecuente, sin embargo en grupo de edad menor (p BACKGROUND: Cardiac involvement is known to occur in patients with Duchenne muscular dystrophy (DMD. The electrocardiogram (ECG shows some typical changes in DMD, which makes it a useful test for the diagnosis of cardiac lesion in this disease. OBJECTIVE: To evaluate the electrocardiographic

  1. Monitorização eletrocardiográfica ambulatorial por 24-horas em cães com cardiomiopatia dilatada idiopática Twenty-four-hour ambulatory electrocardiographic monitoring in dogs with idiopathic dilated cardiomyopathy

    Directory of Open Access Journals (Sweden)

    F.L. Yamaki

    2007-12-01

    Full Text Available Caracterizou-se monitorização eletrocardiográfica ambulatorial por 24 horas (ou monitorização Holter em cães com cardiomiopatia dilatada idiopática, visando principalmente à detecção de arritmias ventriculares não detectadas pela eletrocardiografia convencional (de repouso. Para tanto, avaliaram-se 40 pacientes com diagnóstico de cardiomiopatia dilatada idiopática, por meio de exame físico e mensuração indireta da pressão arterial, além de exames eletrocardiográfico, ecocardiográfico, radiográfico de tórax e da monitorização Holter. Extra-sístoles ventriculares foram detectadas, por monitorização Holter, em 97,5% dos animais e taquicardia ventricular, em 45%. Não houve correlação entre o número de extra-sístoles ventriculares e a fração de encurtamento. Considerando as manifestações clínicas, apenas houve associação entre presença de taquicardia ventricular e histórico de síncopes. Conclui-se que a incidência de arritmias ventriculares em cães com cardiomiopatia dilatada idiopática é bastante alta, sendo a taquicardia ventricular relativamente freqüente, ocorrendo mais sob a forma não sustentada.This study aimed to characterize 24-hour ambulatory electrocardiographic monitoring (Holter monitoring in dogs with idiopathic dilated cardiomyopathy. Physical examination and indirect (Doppler blood pressure measurement, and also electrocardiography, thoracic radiography, echocardiography, and 24-hour ambulatory electrocardiographic exams were performed in 40 dogs with idiopathic dilated cardiomyopathy. Ventricular extrasystoles were detected in 97.5% of the animals, and ventricular tachycardia in 45%. No correlation between the number of ventricular extrasystoles and the shortening fraction was observed. Concerning the clinical symptoms, there was only association between the presence of ventricular tachycardia and past report of syncope. It was concluded that the incidence of ventricular arrhythmias is

  2. Syndrome of diminished vasodilator reserve of the coronary microcirculation (microvascular angina or syndrome X): Diagnosis by combined atrial pacing and thallium 201 imaging--a case report

    International Nuclear Information System (INIS)

    Magarian, G.J.; Palac, R.; Reinhart, S.

    1990-01-01

    Patients with angina-like chest pain without evidence of epicardial coronary artery disease or coronary arterial vasospasm are becoming increasingly recognized. These are often related to noncardiac causes including esophageal, musculoskeletal, and hyperventilatory or panic states. However, recently a subgroup of such patients are being recognized as having true myocardial ischemia and chest pain on the basis of diminished coronary microvascular vasodilatory reserve (microvascular ischemia or Syndrome X). The authors describe such a patient who was found to have replication of anginal pain associated with a reversible ischemic defect on thallium 201 imaging during atrial pacing, suggesting ischemia in this myocardial segment. Resolution of angina and ST segment electrocardiographic changes of ischemia occurred with cessation of pacing. We believe this is the first report of a patient with this form of myocardial ischemia diagnosed by this method and should be considered in patients with anginal chest pain after significant coronary artery disease and coronary vasospasm have been excluded

  3. Electrocardiograph-gated single photon emission computed tomography radionuclide angiography presents good interstudy reproducibility for the quantification of global systolic right ventricular function.

    Science.gov (United States)

    Daou, Doumit; Coaguila, Carlos; Vilain, Didier

    2007-05-01

    Electrocardiograph-gated single photon emission computed tomography (SPECT) radionuclide angiography provides accurate measurement of right ventricular ejection fraction and end-diastolic and end-systolic volumes. In this study, we report the interstudy precision and reliability of SPECT radionuclide angiography for the measurement of global systolic right ventricular function using two, three-dimensional volume processing methods (SPECT-QBS, SPECT-35%). These were compared with equilibrium planar radionuclide angiography. Ten patients with chronic coronary artery disease having two SPECT and planar radionuclide angiography acquisitions were included. For the right ventricular ejection fraction, end-diastolic volume and end-systolic volume, the interstudy precision and reliability were better with SPECT-35% than with SPECT-QBS. The sample sizes needed to objectify a change in right ventricular volumes or ejection fraction were lower with SPECT-35% than with SPECT-QBS. The interstudy precision and reliability of SPECT-35% and SPECT-QBS for the right ventricle were better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography on the same population. SPECT-35% and SPECT-QBS present good interstudy precision and reliability for right ventricular function, with the results favouring the use of SPECT-35%. The results are better than those of equilibrium planar radionuclide angiography, but poorer than those previously reported for the left ventricle with SPECT radionuclide angiography. They need to be confirmed in a larger population.

  4. A Unique Digital Electrocardiographic Repository for the Development of Quantitative Electrocardiography and Cardiac Safety: The Telemetric and Holter ECG Warehouse (THEW)

    Science.gov (United States)

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community in order to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following three components: data, expertise and tools. The Data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous ECG signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the AHA-BIH Arrhythmia Database, and the CSE database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available to the worldwide scientific community. PMID:20863512

  5. Altered carotid plaque signal among different repetition times on T1-weighted magnetic resonance plaque imaging with self-navigated radial-scan technique

    Energy Technology Data Exchange (ETDEWEB)

    Narumi, Shinsuke; Ohba, Hideki; Mori, Kiyofumi; Ohura, Kazumasa; Ono, Ayumi; Terayama, Yasuo [Iwate Medical University, Department of Neurology and Gerontology, Morioka (Japan); Sasaki, Makoto [Iwate Medical University, Advanced Medical Research Center, Morioka (Japan); Ogasawara, Kuniaki [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Hitomi, Jiro [Iwate Medical University, Department of Anatomy, Morioka (Japan)

    2010-04-15

    Magnetic resonance (MR) plaque imaging for carotid arteries is usually performed by using an electrocardiograph (ECG)-gating technique to eliminate pulsation-related artifacts, which can affect the plaque signals because of varied repetition time (TR) among patients. Hence, we investigated whether differences in TR causes signal alterations of the carotid plaque by using a non-gated plaque imaging technique. We prospectively examined 19 patients with carotid stenosis by using a T1-weighted self-navigated radial-scan technique with TRs of 500, 700, and 900 ms. The signal intensity of the carotid plaque was measured, and the contrast ratio (CR) relative to the adjacent muscle was calculated. CRs of the carotid plaques were 1.39 {+-} 0.39, 1.29 {+-} 0.29, and 1.23 {+-} 0.24 with TRs of 500, 700, and 900 ms, respectively, and were significantly different. Among the plaques, those with a hyperintensity signal (CR > 1.5) and moderate-intensity signal (CR 1.2-1.5) at 500 ms showed a TR-dependent signal decrease (hyperintensity plaques, 1.82 {+-} 0.26; 1.61 {+-} 0.19; and 1.48 {+-} 0.17; moderate-intensity plaques, 1.33 {+-} 0.08; 1.26 {+-} 0.08; and 1.19 {+-} 0.07), while those with an isointensity signal (CR < 1.2) remained unchanged regardless of TR (0.96 {+-} 0.12, 0.96 {+-} 0.11, and 0.97 {+-} 0.13). The signal intensity of the carotid plaque on T1-weighted imaging significantly varies among different TRs and tends to decrease with longer TR. MR plaque imaging with short and constant TR settings that the ECG-gating method cannot realize would be preferable for evaluating plaque characteristics. (orig.)

  6. Usefulness of acute myocardial infarct size and localization using Tc-99m-pyrophosphate and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujisue, Ryu; Ohyanagi, Mitsumasa; Todo, Yasuhiro

    1985-01-01

    Tc-99m-Pyrophosphate(PYP)myocardial emission computed tomography(ECT) was performed following standard planar imaging in 45 patients(pts) with acute myocardial infarction(AMI). All of them had clinical, electrocardiographic and enzymatic evidence of AMI. The planar imaging and ECT imaging were interpreted independently by two observers who had no knowledge of the clinical findings. 10 pts(22.2 %), who showed diffuse uptake on planar imaging, revealed focal uptake on ECT imaging without cardiac blood pool imaging. And there is no disagreement as to interpretation of the infarct location by two observers on ECT imaging. We conclude that ECT imaging with Tc-99m-PYP increases interobserver agreement in the diagnosis and localization of AMI and may lead to more accurate localization and sizing of AMI, espesically in cases of diffuse cardiac activity on planar imaging. (author)

  7. Imaging of pannus formation in patients with mechanical heart valves.

    Science.gov (United States)

    Gündüz, Sabahattin; Özkan, Mehmet; Yesin, Mahmut

    2015-11-26

    Patient-prosthesis mismatch (PPM) should be recognized in patients with elevated transprosthetic gradients but without leaflet immobility, since the treatment strategy may differ in either etiology. However, thrombus and/or pannus formation should be excluded before a diagnosis of PPM is made. Particularly, pannus formation may not be diagnosed with 2-dimensional transesophageal echocardiography. Electrocardiographically gated 64-section multidetector computed tomography (MDCT) may be a promising tool in diagnosing or excluding pannus formation. Our report underlines the utility of MDCT in this regard and also emphasizes the importance of recognition of PPM as a differential diagnosis in such patients.

  8. Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

    International Nuclear Information System (INIS)

    Navare, Sachin M.; Liu, Yi-Hwa; Wackers, Frans J.T.

    2003-01-01

    Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122±72 ml vs 115±68 ml, P<0.0001), smaller ESV (64±58.6 ml vs 67.6±59.5 ml, P<0.0001), and higher LVEF (55.3%±18% vs 49%±17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET. (orig.)

  9. Office and Home Blood Pressures as Determinants of Electrocardiographic Left Ventricular Hypertrophy Among Black Nigerians Compared With White Flemish.

    Science.gov (United States)

    Odili, Augustine N; Thijs, Lutgarde; Yang, Wen-Yi; Ogedengbe, John O; Nwegbu, Maxwell M; Jacobs, Lotte; Wei, Fang-Fei; Feng, Ying-Mei; Zhang, Zhen-Yu; Kuznetsova, Tatiana; Nawrot, Tim S; Staessen, Jan A

    2017-11-01

    The association of electrocardiographic left ventricular hypertrophy (ECG-LVH) with blood pressure (BP) in Blacks living in sub-Saharan Africa remains poorly documented. In 225 Black Nigerians and 729 White Flemish, we analyzed QRS voltages and voltage-duration products and 12 criteria diagnostic of ECG-LVH in relation to office BP (mean of 5 consecutive readings) and home BP (duplicate morning and evening readings averaged over 1 week). In multivariable analyses, QRS voltage and voltage-duration indexes were generally higher in Blacks than Whites. By using any of 12 criteria, ECG-LVH was more prevalent among Black than White men (54.4% vs. 36.0%) with no ethnic difference among women (17.1%). Precordial voltages and voltage-duration products increased with office and home systolic BP (SBP), and increases were up to 3-fold steeper in Blacks. In Blacks vs. Whites, increases in the Sokolow-Lyon voltage associated with a 10-mm Hg higher SBP were 0.18 mV (95% confidence interval [CI], 0.09-0.26) vs. 0.06 mV (0.02-0.09) and 0.17 mV (0.07-0.28) vs. 0.11 mV (CI, 0.07-0.15) for office and home BP, respectively, with a significant ethnic gradient (P office and home BP in Blacks than Whites. Associations of ECG voltages and voltage-duration products and risk of ECG-LVH with BP are steeper in Black Nigerians compared with a White reference population. In resource-poor settings of sub-Saharan Africa, the ECG in combination with office and home BP is an essential instrument in risk stratification across the entire BP range. © The Author 2017. Published by Oxford University Press on behalf of the American Journal of Hypertension, Ltd.

  10. Local Wavelet-Based Filtering of Electromyographic Signals to Eliminate the Electrocardiographic-Induced Artifacts in Patients with Spinal Cord Injury.

    Science.gov (United States)

    Nitzken, Matthew; Bajaj, Nihit; Aslan, Sevda; Gimel'farb, Georgy; El-Baz, Ayman; Ovechkin, Alexander

    2013-07-18

    Surface Electromyography (EMG) is a standard method used in clinical practice and research to assess motor function in order to help with the diagnosis of neuromuscular pathology in human and animal models. EMG recorded from trunk muscles involved in the activity of breathing can be used as a direct measure of respiratory motor function in patients with spinal cord injury (SCI) or other disorders associated with motor control deficits. However, EMG potentials recorded from these muscles are often contaminated with heart-induced electrocardiographic (ECG) signals. Elimination of these artifacts plays a critical role in the precise measure of the respiratory muscle electrical activity. This study was undertaken to find an optimal approach to eliminate the ECG artifacts from EMG recordings. Conventional global filtering can be used to decrease the ECG-induced artifact. However, this method can alter the EMG signal and changes physiologically relevant information. We hypothesize that, unlike global filtering, localized removal of ECG artifacts will not change the original EMG signals. We develop an approach to remove the ECG artifacts without altering the amplitude and frequency components of the EMG signal by using an externally recorded ECG signal as a mask to locate areas of the ECG spikes within EMG data. These segments containing ECG spikes were decomposed into 128 sub-wavelets by a custom-scaled Morlet Wavelet Transform. The ECG-related sub-wavelets at the ECG spike location were removed and a de-noised EMG signal was reconstructed. Validity of the proposed method was proven using mathematical simulated synthetic signals and EMG obtained from SCI patients. We compare the Root-mean Square Error and the Relative Change in Variance between this method, global, notch and adaptive filters. The results show that the localized wavelet-based filtering has the benefit of not introducing error in the native EMG signal and accurately removing ECG artifacts from EMG signals.

  11. [Experience in the use of equipment for ECG system analysis in municipal polyclinics].

    Science.gov (United States)

    Bondarenko, A A

    2006-01-01

    Two electrocardiographs, an analog-digital electrocardiograph with preliminary analog filtering of signal and a smart cardiograph implemented as a PC-compatible device without preliminary analog filtering, are considered. Advantages and disadvantages of ECG systems based on artificial intelligence are discussed. ECG interpretation modes provided by the two electrocardiographs are considered. The reliability of automatic ECG interpretation is assessed. Problems of rational use of automated ECG processing systems are discussed.

  12. Cardiac imaging using 256-detector row four-dimensional CT. Preliminary clinical report

    International Nuclear Information System (INIS)

    Kido, Teruhito; Kurata, Akira; Higashino, Hiroshi

    2007-01-01

    Along with the increase of detector rows on the z-axis and a faster gantry rotation speed, the spatial and temporal resolutions of the multislice computed tomography (CT) have been improved for noninvasive coronary artery imaging. We investigated the feasibility of the second specification prototype 256-detector row four-dimensional CT for assessing coronary artery and cardiac function. The subjects were five patients with coronary artery disease. Contrast medium (40-60 ml) was intravenously administered at the rate of 3-4 ml/s. The patient's whole heart was scanned for 1.5 s to cover at least one cardiac cycle during breathholding without electrocardiographic gating. Parameters used were 0.5 mm slice thickness, 0.5 s/rotation, 120 Kv, and 350 mA, with a half-scan reconstruction algorithm (temporal resolution 250 ms). Twenty-six transaxial datasets were reconstructed at intervals of 50 ms. The assessability of the coronary arteries in American Heart Association (AHA) segments 1, 2, 3, 5, 6, 7, 9, and 11 was visually evaluated, resulting in 29 of 32 (90.9%) segments being assessable. Functional assessment was also performed using animated movies without banding artifacts in all cases. The 256-detector row four-dimensional CT can assess the coronary artery and cardiac function using data during 1.5 s without banding artifacts. (author)

  13. Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Qianjun, E-mail: jiaqianjun@126.com [Southern Medical University, Guangzhou, Guangdong (China); Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Zhuang, Jian, E-mail: zhuangjian5413@tom.com [Department of Cardiac Surgery, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Jiang, Jun, E-mail: 81711587@qq.com [Department of Radiology, Shenzhen Second People’s Hospital, Shenzhen, Guangdong (China); Li, Jiahua, E-mail: 970872804@qq.com [Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Huang, Meiping, E-mail: huangmeiping_vip@163.com [Department of Catheterization Lab, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Southern Medical University, Guangzhou, Guangdong (China); Liang, Changhong, E-mail: cjr.lchh@vip.163.com [Department of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Southern Medical University, Guangzhou, Guangdong (China)

    2017-01-15

    Purpose: To compare the image quality, rate of coronary artery visualization and diagnostic accuracy of 256-slice multi-detector computed tomography angiography (CTA) with prospective electrocardiographic (ECG) triggering at a tube voltage of 80 kVp between 3 reconstruction algorithms (filtered back projection (FBP), hybrid iterative reconstruction (iDose{sup 4}) and iterative model reconstruction (IMR)) in infants with congenital heart disease (CHD). Methods: Fifty-one infants with CHD who underwent cardiac CTA in our institution between December 2014 and March 2015 were included. The effective radiation doses were calculated. Imaging data were reconstructed using the FBP, iDose{sup 4} and IMR algorithms. Parameters of objective image quality (noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)); subjective image quality (overall image quality, image noise and margin sharpness); coronary artery visibility; and diagnostic accuracy for the three algorithms were measured and compared. Results: The mean effective radiation dose was 0.61 ± 0.32 mSv. Compared to FBP and iDose{sup 4}, IMR yielded significantly lower noise (P < 0.01), higher SNR and CNR values (P < 0.01), and a greater subjective image quality score (P < 0.01). The total number of coronary segments visualized was significantly higher for both iDose{sup 4} and IMR than for FBP (P = 0.002 and P = 0.025, respectively), but there was no significant difference in this parameter between iDose{sup 4} and IMR (P = 0.397). There was no significant difference in the diagnostic accuracy between the FBP, iDose{sup 4} and IMR algorithms (χ{sup 2} = 0.343, P = 0.842). Conclusions: For infants with CHD undergoing cardiac CTA, the IMR reconstruction algorithm provided significantly increased objective and subjective image quality compared with the FBP and iDose{sup 4} algorithms. However, IMR did not improve the diagnostic accuracy or coronary artery visualization compared with iDose{sup 4}.

  14. Association of heart failure hospitalizations with combined electrocardiography and echocardiography criteria for left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Gerdts, Eva; Okin, Peter M; Boman, Kurt

    2012-01-01

    The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain.......The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain....

  15. Takotsubo cardiomyopathy

    DEFF Research Database (Denmark)

    Nielsen, Lene Hüche; Munk, Kim; Goetzsche, Ole

    2009-01-01

    INTRODUCTION: Sparse information with regard to the electrocardiographic (ECG) changes in Takotsubo cardiomyopathy (TC) is available. The purpose of this study was to describe the clinical characteristics and electrocardiographic changes in a Danish cohort of patients with TC. We discuss the pote......INTRODUCTION: Sparse information with regard to the electrocardiographic (ECG) changes in Takotsubo cardiomyopathy (TC) is available. The purpose of this study was to describe the clinical characteristics and electrocardiographic changes in a Danish cohort of patients with TC. We discuss...... retrospectively from medical records and the hospitals laboratory database. RESULTS: Seven patients with TC were identified comprising six females and one male (mean age 70, range 53-81 years). In the acute phase all patients had ECG changes compatible with ST-elevation acute myocardial infarction (STEMI...

  16. Multi-detector computed tomography (MDCT imaging of cardiovascular effects of pulmonary embolism: What the radiologists need to know

    Directory of Open Access Journals (Sweden)

    Mohamed Aboul-fotouh E. Mourad

    2017-09-01

    Full Text Available Background: Patients with pulmonary embolism have high mortality and morbidity rate due to right heart failure and circulatory collapse leading to sudden death. Multi-detector computed tomography MDCT can efficiently evaluate the cardiovascular factors related to pulmonary embolism. Objectives: To evaluate the diagnostic accuracy of multi-detector computed tomography (MDCT in differentiation of between sever and non-severe pulmonary embolism groups depending on the associated cardiovascular parameters and create a simple reporting system. Patients & methods: Prospective study contained 145 patients diagnosed clinically pulmonary embolism. All patients were examined by combined electrocardiographically gated computed tomography pulmonary angiography-computed tomography venography (ECG-CTPA-CTV using certain imaging criteria in a systematic manner. Results: Our study revealed 95 and 55 non-severe and severe pulmonary embolism groups respectively. Many cardiovascular parameters related to pulmonary embolism shows significant p value and can differentiate between sever and non-severe pulmonary embolism patients include pulmonary artery diameter, intraventricular septum flattening, bowing, superior vena cava and Azygos vein diameters, right and left ventricular diameters. Conclusion: Multi-detector computed tomography (MDCT can be valuable to assess the severity of pulmonary embolism using the related cardiovascular parameters and leading the management strategy aim for best outcome. Keywords: Pulmonary embolism, MDCT, Cardiovascular, Computed tomography venography

  17. Clinical use of the combined Sclarovsky Birnbaum Severity and Anderson Wilkins Acuteness scores from the pre-hospital ECG in ST-segment elevation myocardial infarction

    DEFF Research Database (Denmark)

    Fakhri, Yama; Schoos, Mikkel M; Clemmensen, Peter

    2014-01-01

    This review summarizes the electrocardiographic changes during an evolving ST segment elevation myocardial infarction and discusses associated electrocardiographic scores and the potential use of these indices in clinical practice, in particular the ECG scores developed by Anderson and Wilkins...

  18. Cardiac involvement in Beagle-based canine X-linked muscular dystrophy in Japan (CXMDJ: electrocardiographic, echocardiographic, and morphologic studies

    Directory of Open Access Journals (Sweden)

    Machida Noboru

    2006-12-01

    Full Text Available Abstract Background Cardiac mortality in Duchenne muscular dystrophy (DMD has recently become important, because risk of respiratory failure has been reduced due to widespread use of the respirator. The cardiac involvement is characterized by distinctive electrocardiographic abnormalities or dilated cardiomyopathy, but the pathogenesis has remained obscure. In research on DMD, Golden retriever-based muscular dystrophy (GRMD has attracted much attention as an animal model because it resembles DMD, but GRMD is very difficult to maintain because of their severe phenotypes. We therefore established a line of dogs with Beagle-based canine X-linked muscular dystrophy in Japan (CXMDJ and examined the cardiac involvement. Methods The cardiac phenotypes of eight CXMDJ and four normal male dogs 2 to 21 months of age were evaluated using electrocardiography, echocardiography, and histopathological examinations. Results Increases in the heart rate and decreases in PQ interval compared to a normal littermate were detected in two littermate CXMDJ dogs at 15 months of age or older. Distinct deep Q-waves and increase in Q/R ratios in leads II, III, and aVF were detected by 6–7 months of age in all CXMDJ dogs. In the echocardiogram, one of eight of CXMDJ dogs showed a hyperechoic lesion in the left ventricular posterior wall at 5 months of age, but the rest had not by 6–7 months of age. The left ventricular function in the echocardiogram indicated no abnormality in all CXMDJ dogs by 6–7 months of age. Histopathology revealed myocardial fibrosis, especially in the left ventricular posterobasal wall, in three of eight CXMDJ dogs by 21 months of age. Conclusion Cardiac involvement in CXMDJ dogs is milder and has slower progression than that described in GRMD dogs. The distinct deep Q-waves have been ascribed to myocardial fibrosis in the posterobasal region of the left ventricle, but our data showed that they precede the lesion on echocardiogram and

  19. Accuracy of remote electrocardiogram interpretation with the use of Google Glass technology.

    Science.gov (United States)

    Jeroudi, Omar M; Christakopoulos, George; Christopoulos, George; Kotsia, Anna; Kypreos, Megan A; Rangan, Bavana V; Banerjee, Subhash; Brilakis, Emmanouil S

    2015-02-01

    We sought to investigate the accuracy of remote electrocardiogram (ECG) interpretation using Google Glass (Google, Mountain View, California). Google Glass is an optical head mounted display device with growing applications in medicine. We compared interpretation of 10 ECGs with 21 clinically important findings by faculty and fellow cardiologists by (1) viewing the electrocardiographic image at the Google Glass screen; (2) viewing a photograph of the ECG taken using Google Glass and interpreted on a mobile device; (3) viewing the original paper ECG; and (4) viewing a photograph of the ECG taken with a high-resolution camera and interpreted on a mobile device. One point was given for identification of each correct finding. Subjective rating of the user experience was also recorded. Twelve physicians (4 faculty and 8 fellow cardiologists) participated. The average electrocardiographic interpretation score (maximum 21 points) as viewed through the Google Glass, Google Glass photograph on a mobile device, on paper, and high-resolution photograph on a mobile device was 13.5 ± 1.8, 16.1 ± 2.6, 18.3 ± 1.7, and 18.6 ± 1.5, respectively (p = 0.0005 between Google Glass and mobile device, p = 0.0005 between Google Glass and paper, and p = 0.002 between mobile device and paper). Of the 12 physicians, 9 (75%) were dissatisfied with ECGs viewing on the prism display of Google Glass. In conclusion, further improvements are needed before Google Glass can be reliably used for remote electrocardiographic analysis. Published by Elsevier Inc.

  20. Takotsubo cardiomyopathy in the case of 72-year-old teacher after work-related psychological stress. Evolution of left ventricular longitudinal strain – Delayed but complete recovery in automated function imaging (AFI

    Directory of Open Access Journals (Sweden)

    Karina Wierzbowska-Drabik

    2017-08-01

    Full Text Available Takotsubo cardiomyopathy (TC is related to a transient systolic dysfunction of left ventricle (LV, accompanied by clinical and electrocardiographic symptoms of myocardial ischemia in the absence of hemodynamically significant coronary artery disease. Takotsubo cardiomyopathy is usually provoked by a psychologically or/and physically stressful event which may be related to occupational activities. Although visually assessed evolution of LV function is well documented, the data concerning strain changes is sparse and various patterns of deformation abnormalities are suggested. We have described a 72-year-old woman with chest pain related to a lecture given at the meeting of the Senior University, fulfilling all the Mayo Clinic criteria of the TC. The longitudinal strain analysis with automated function imaging (AFI documented severe impairment and stepwise recovery of regional and global LV contractility. The case described confirms that accurate diagnosis, treatment and documenting of functional improvement in takotsubo cardiomyopathy may enable the return to occupational activities even for elderly persons. Int J Occup Med Environ Health 2017;30(4:681–683

  1. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  2. Diagnosis of ischaemic heart disease with thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Human, G P [Pretoria Univ. (South Africa). Dept. of Internal Medicine; Dormehl, I [Atomic Energy Board, Pelindaba, Pretoria (South Africa). Life Sciences Div.

    1981-04-04

    Thallium-201 is very suitable for cardiac imaging because of its physical characteristics and biological behaviour. Perfusion defects caused by ischaemia, necrosis or fibrosis are represented by 'cold spots' on the myocardial scan. In this article we report our experience with this method in the diagnosis of ischaemic heart disease in 117 patients. Excellent correlation was found with clinical, electrocardiographic and angiographic parameters. Both sensitivity and specificity for the diagnosis of ischaemic heart disease were higher with /sup 201/Tl scintigraphy than with existing diagnostic methods.

  3. Identifying drug-induced repolarization abnormalities from distinct ECG patterns in congenital long QT syndrome: a study of sotalol effects on T-wave morphology

    DEFF Research Database (Denmark)

    Graff, Claus; Andersen, Mads P; Xue, Joel Q

    2009-01-01

    BACKGROUND: The electrocardiographic QT interval is used to identify drugs with potential harmful effects on cardiac repolarization in drug trials, but the variability of the measurement can mask drug-induced ECG changes. The use of complementary electrocardiographic indices of abnormal repolariz......BACKGROUND: The electrocardiographic QT interval is used to identify drugs with potential harmful effects on cardiac repolarization in drug trials, but the variability of the measurement can mask drug-induced ECG changes. The use of complementary electrocardiographic indices of abnormal...... are typical ECG patterns in LQT2. Blinded to labels, the new morphology measures were tested in a third group of 39 healthy subjects receiving sotalol. Over 3 days the sotalol group received 0, 160 and 320 mg doses, respectively, and a 12-lead Holter ECG was recorded for 22.5 hours each day. Drug...... with QTcF, p ECG patterns in LQT2 carriers effectively quantified repolarization changes induced by sotalol. Further studies are needed to validate whether this measure has...

  4. A Report of Brugada Syndrome Presenting with Cardiac Arrest Triggered by Verapamil Intoxication.

    Science.gov (United States)

    Yakut, Kahraman; Erdoğan, İlkay; Varan, Birgül; Atar, İlyas

    2017-12-01

    Brugada syndrome is a disease characterized by a specific electrocardiographic pattern and an increased risk of sudden cardiac death. We present this case with the updated literature to emphasise the need to consider the diagnosis of Brugada syndrome in patients admitted to the emergency ward with sudden cardiac arrest. A 16-year-old female patient was admitted to the emergency ward with complaints of weakness and abdominal pain, and she had four cardiac arrests during her evaluation period. She was referred to our clinic for permanent pacemaker implantation. She was on a temporary pace maker after having had C-reactive protein. Her physical exam was normal except for bilaterally decreased lung sounds. Lung x-ray and computed tomography, which were performed by another institution, revealed minimal pleural effusion and nothing else of significance. Blood and peritoneal fluid samples were sterile. Echocardiographic exam and cardiac enzymes were also in the normal ranges. Electrocardiographic showed incomplete right branch block in leads V1 and V2. An ajmaline test revealed specific electrocardiographic findings of the type I Brugada pattern. We proposed implanting an implantable cardioverter defibrillator to the patient as there were positive findings on the ajmaline test as well as a history of sudden cardiac arrest. After this treatment proposal, the patient's family admitted that she had taken a high dose of verapamil and thus, the encountered bradycardia was associated with verapamil overuse. The ajmaline test was repeated as it was contemplated that the previous positive ajmaline test had been associated with verapamil overuse. Implantable cardioverter defibrillator implantation was proposed again as there was a history of sudden cardiac arrest; however, the family did not consent to implantable cardioverter defibrillator, and the patient was discharged and followed up. Brugada syndrome should be considered for patients who are admitted to the emergency ward

  5. Computed tomography of the heart and great vessels: present and future

    International Nuclear Information System (INIS)

    Brundage, B.H.; Rich, S.; Spigos, D.

    1984-01-01

    Computed tomography (CT) has emerged as a new imaging method for the diagnosis and evaluation of cardiovascular disease. With CT body scanners and contrast enhancement, evaluation of aortic dissections and aneurysms, coronary bypass graft patency, cardiovascular thrombus, cardiac tumors, and pericardial disease is possible. On occasion, this technique provides clinically useful information that is not available with other imaging methods. Electrocardiographic gating retrospectively or prospectively improves the image resolution of CT scans, but a new ultrafast CT scanner with a scan time of 30 to 50 milliseconds offers the greatest promise for expanding the application of the technology for cardiovascular diagnosis. Accurate measurement of cardiac chamber volume, mass, wall motion, and wall thickening will be feasible. Ultrafast CT scanning also shows great promise for the measurement of myocardial infarct size and regional myocardial blood flow

  6. Detection and assessment of unstable angina using myocardial perfusion imaging: Comparison between technetium-99m sestamibi SPECT and 12-lead electrocardiogram

    International Nuclear Information System (INIS)

    Gregoire, J.; Theroux, P.

    1990-01-01

    Forty-five studies using technetium-99m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) were performed on patients hospitalized for spontaneous chest pain suggestive of myocardial ischemia. The studies were done after an injection during an episode of chest pain and a repeated injection when the patients were free of pain. All patients were hospitalized with a presumed diagnosis of unstable angina, and none had evidence of a previous myocardial infarction. The presence of a perfusion defect observed with Tc-99m sestamibi injected during chest pain had a 96% sensitivity and a 79% specificity for the detection of significant coronary artery disease (stenosis greater than or equal to 50%) on subsequent angiography. When the criterion of a larger perfusion defect during pain compared to absence of pain was used, the sensitivity was 81% and the specificity was 84%. In contrast, transient electrocardiographic ischemic changes during pain had a sensitivity of 35% and a specificity of 68%; electrocardiographic changes during or outside episodes of chest pain had a sensitivity of 65% and a specificity of 63% for the diagnosis. Tc-99m sestamibi SPECT represents a reliable noninvasive diagnostic tool that could aid in the diagnosis of myocardial ischemia in patients with spontaneous chest pain and provide additional information to that provided by the electrocardiogram

  7. Características eletrocardiográficas em eqüinos clinicamente normais da raça Puro Sangue Inglês Electrocardiographic parameters in clinically healthy Thoroughbred horses

    Directory of Open Access Journals (Sweden)

    W.R. Fernandes

    2004-04-01

    Full Text Available Determinaram-se as características eletrocardiográficas de amplitude, duração, ritmo e eixo cardíaco no plano frontal de potros, sobreanos e éguas prenhes clinicamente normais, da raça Puro Sangue Inglês. Estudaram-se 50 potros e 50 sobreanos, machos e fêmeas, e 11 éguas prenhes. Concluiu-se que a freqüência cardíaca diminui com a idade e que nos potros e sobreanos as características apresentaram valores intermediários entre os valores padrão de neonatos e adultos. Nos sobreanos eles estão mais próximos dos de referência para adultos. Nas éguas em gestação a única diferença observada com o padrão foi o leve desvio para a direita do eixo cardíaco.The determination of the electrocardiographic parameters of amplitude, duration, rhythm and electrical axis in the frontal plane from clinically healthy Thoroughbred foals, yearlings and pregnant mares was performed. Fifty foals and 50 yearlings, males and females, and 11 pregnant mares were used. It was concluded that the heart rate decreases with age and that foals and yearlings had intermediate values between reference values of neonates and adults. In yearlings, these values were more similar to the reference values of adults. In pregnant mares, the only difference observed when compared to reference values was the slight right displacement of the electrical axis.

  8. Utility of electrocardiogram in the assessment and monitoring of pulmonary hypertension (idiopathic or secondary to pulmonary developmental abnormalities) in patients≤18 years of age.

    Science.gov (United States)

    Lau, Kelvin C; Frank, David B; Hanna, Brian D; Patel, Akash R

    2014-07-15

    Electrocardiograms have utility in disease stratification and monitoring in adult pulmonary arterial hypertension (PAH). We examined the electrocardiographic findings that are common in pediatric PAH and assessed for correlation with disease severity and progression. We retrospectively identified patients aged≤18 years followed at a single institution from January 2001 to June 2012 with catheterization-confirmed diagnosis of idiopathic PAH and PAH secondary to pulmonary developmental abnormalities. Patients with an electrocardiography performed within 60 days of catheterization were included. Primary and secondary outcomes are the prevalence of abnormal electrocardiographic findings at the time of catheterization and the association between electrocardiographic and hemodynamic findings and electrocardiographic changes with disease progression on follow-up catheterization, respectively. Of the 100 electrocardiography-catheterization pairs derived from the 46 patients identified, 93% had an electrocardiographic abnormality: 78% had right ventricular hypertrophy (RVH) and 52% had right axis deviation (RAD) for age. In patients with idiopathic PAH, the presence of RVH and RAD correlated with pulmonary vascular resistance and transpulmonary gradient. RAD and RVH on baseline electrocardiogram was associated with an increased risk of disease progression on subsequent catheterization (odds ratio 11.0, 95% confidence interval 1.3 to 96.2, p=0.03) after adjusting for PAH subgroup. The sensitivity, specificity, and positive and negative predictive values of RAD and RVH on baseline electrocardiogram for disease progression were 92%, 48%, 33%, and 95%, respectively. In conclusion, electrocardiographic abnormalities are common in pediatric PAH. RAD and RVH on electrocardiogram were associated with worse hemodynamics, whereas their absence is suggestive of a lack of disease progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Association of different electrocardiographic patterns with shock index, right ventricle systolic pressure and diameter, and embolic burden score in pulmonary embolism

    Directory of Open Access Journals (Sweden)

    Krća Bojana

    2016-01-01

    Full Text Available Background/Aim. Some electrocardiographic (ECG patterns are characteristic for pulmonary embolism but exact meaning of the different ECG signs are not well known. The aim of this study was to determine the association between four common ECG signs in pulmonary embolism [complete or incomplete right bundle branch block (RBBB, S-waves in the aVL lead, S1Q3T3 sign and negative T-waves in the precordial leads] with shock index (SI, right ventricle diastolic diameter (RVDD and peak systolic pressure (RVSP and embolic burden score (EBS. Methods. The presence of complete or incomplete RBBB, S waves in aVL lead, S1Q3T3 sign and negative T-waves in the precordial leads were determined at admission ECG in 130 consecutive patients admitted to the intensive care unit of a single tertiary medical center in a 5-year period. Echocardiography examination with measurement of RVDD and RVSP, multidetector computed tomography pulmonary angiography (MDCT-PA with the calculation of EBS and SI was determined during the admission process. Multivariable regression models were calculated with ECG parameters as independent variables and the mentioned ultrasound, MDCT-PA parameters and SI as dependent variables. Results. The presence of S-waves in the aVL was the only independent predictor of RVDD (F = 39.430, p < 0.001; adjusted R2 = 0.231 and systolic peak right ventricle pressure (F = 29.903, p < 0.001; adjusted R2 = 0.185. Negative T-waves in precordial leads were the only independent predictor for EBS (F = 24.177, p < 0.001; R2 = 0.160. Complete or incomplete RBBB was the independent predictor of SI (F = 20.980, p < 0.001; adjusted R2 = 0.134. Conclusion. In patients with pulmonary embolism different ECG patterns at admission correlate with different clinical, ultrasound and MDCT-PA parameters. RBBB is associated with shock, Swave in the aVL is associated with right ventricle pressure and negative T-waves with the thrombus burden in the pulmonary tree.

  10. Clinical evaluation of carbon-11-phenylephrine: MAO-sensitive marker of cardiac sympathetic neurons.

    Science.gov (United States)

    Raffel, D M; Corbett, J R; del Rosario, R B; Gildersleeve, D L; Chiao, P C; Schwaiger, M; Wieland, D M

    1996-12-01

    The sympathomimetic drug phenylephrine recently has been labeled with 11C for use in PET studies of cardiac sympathetic innervation. Previous reports using isolated perfused rat heart models indicate that phenylephrine is metabolized by intraneuronal monoamine oxidase (MAO). This report compares the imaging characteristics, neuronal selectivity and kinetics of (-)-[11C]phenylephrine (PHEN) to the structurally similar but MAO-resistant analog (-)-[11C]-meta-hydroxyephedrine (HED), an established heart neuronal marker. Fourteen healthy volunteers were studied with PET and PHEN. Ten had paired studies with HED; four of the 10 were scanned a second time with each tracer after oral administration of desipramine, a selective neuronal transport blocker. Hemodynamic and electrocardiographic responses were monitored. Blood levels of intact radiotracer and radiolabeled metabolites were determined from venous blood samples taken during the PET study. Myocardial retention indices for both tracers were calculated. No hemodynamic or electrocardiographic effects were observed with either tracer. PHEN showed reduced myocardial retention at 50 min compared to HED; however, image quality and uniformity of distribution were comparable. PHEN cleared from myocardium with a mean half-time of 59 +/- 5 min, while myocardial levels of HED remained constant. PHEN metabolites appeared in the blood approximately three times faster than HED metabolites. Desipramine pretreatment markedly reduced (> 60%) myocardial retention of both PHEN and HED. PHEN provides PET images of human heart comparable in quality and uniformity to HED. Like HED, PHEN localizes in the sympathetic nerves of the heart. However, the more rapid efflux of PHEN, that is likely mediated by MAO, may provide information on the functional status of cardiac sympathetic neurons unobtainable with HED.

  11. Effect of Head-Down Bed Rest and Artificial Gravity Countermeasure on Cardiac Autonomic and Advanced Electrocardiographic Function

    Science.gov (United States)

    Schlegel, T. T.; Platts, S.; Stenger, M.; Ribeiro, C.; Natapoff, A.; Howarth, M.; Evans, J.

    2007-01-01

    To study the effects of 21 days of head-down bed rest (HDBR), with versus without an artificial gravity (AG) countermeasure, on cardiac autonomic and advanced electrocardiographic function. Fourteen healthy men participated in the study: seven experienced 21 days of HDBR alone ("HDBR controls") and seven the same degree and duration of HDBR but with approximately 1hr daily short-arm centrifugation as an AG countermeasure ("AG-treated"). Five minute supine high-fidelity 12-lead ECGs were obtained in all subjects: 1) 4 days before HDBR; 2) on the last day of HDBR; and 3) 7 days after HDBR. Besides conventional 12-lead ECG intervals and voltages, all of the following advanced ECG parameters were studied: 1) both stochastic (time and frequency domain) and deterministic heart rate variability (HRV); 2) beat-to-beat QT interval variability (QTV); 3) T-wave morphology, including signal-averaged T-wave residua (TWR) and principal component analysis ratios; 4) other SAECG-related parameters including high frequency QRS ECG and late potentials; and 5) several advanced ECG estimates of left ventricular (LV) mass. The most important results by repeated measures ANOVA were that: 1) Heart rates, Bazett-corrected QTc intervals, TWR, LF/HF power and the alpha 1 of HRV were significantly increased in both groups (i.e., by HDBR), but with no relevant HDBR*group differences; 2) All purely "vagally-mediated" parameters of HRV (e.g., RMSSD, HF power, Poincare SD1, etc.), PR intervals, and also several parameters of LV mass (Cornell and Sokolow-Lyon voltages, spatial ventricular activation times, ventricular gradients) were all significantly decreased in both groups (i.e., by HDBR), but again with no relevant HDBR*group differences); 3) All "generalized" or "vagal plus sympathetic" parameters of stochastic HRV (i.e., SDNN, total power, LF power) were significantly more decreased in the AG-treated group than in the HDBR-only group (i.e., here there was a relevant HDBR*group difference

  12. DISCINESIA ÁNTERO-APICAL TRANSITORIA O SÍNDROME DE TAKO-TSUBO. PRESENTACIÓN DE UN CASO / Transient antero-apical dyskinesia or tako-tsubo syndrome. A case report

    Directory of Open Access Journals (Sweden)

    Dayán A. García Cuesta

    2011-09-01

    Full Text Available Transient apical ballooning, Tako-tsubo syndrome (and other synonyms, is a clinical condition first described in Japan, and then in other countries, that mimics acute myocardial infarction. Disorders of left ventricular contractility recover within a few weeks. The fatality rate is very low compared with infarction, but it should be known by professionals that see patients with acute coronary syndrome in the emergency department. A patient who was discharged from our department with this diagnosis is presented, and electrocardiographic, echocardiographic and angiographic images are shown.

  13. Rural medicine via mobile network

    International Nuclear Information System (INIS)

    Srivastava, Shikha; Bharade, Sandeep; Sinha, Vineet; Ananthakrishnan, T.S.; Jindal, G.D.; Prakash, C.

    2009-01-01

    Bhabha Atomic Research Centre (BARC) has developed a handheld Tele-ECG system for providing optimum cardiac care and a Mobile Network Based Telemedicine (MNBT) utility for providing telemedicine services to isolated rural population. The handheld Tele-ECG acquires, saves and transfers the electrocardiographic signal to the expert's mobile for his advice in dealing with cardiac emergencies. Similarly, MNBT utility transfers the medical images and relevant patient data from a PC based instrument to a mobile phone for further transmission to an expert for his advice. This paper summarizes these developments. (author)

  14. Differential diagnosis between early repolarization of athlete's heart and coved-type Brugada electrocardiogram.

    Science.gov (United States)

    Zorzi, Alessandro; Leoni, Loira; Di Paolo, Fernando M; Rigato, Ilaria; Migliore, Federico; Bauce, Barbara; Pelliccia, Antonio; Corrado, Domenico

    2015-02-15

    Early repolarization (ER) is typically observed in highly trained athletes as a physiologic consequence of increased vagal tone. The variant of anterior (V1 to V3) ER characterized by "domed" ST-segment elevation and negative T wave raises problems of differential diagnosis with the "coved-type" electrocardiographic pattern seen in Brugada syndrome (BS). This study was designed to identify electrocardiographic criteria for distinguishing athlete's ER from BS. The study compared the electrocardiographic tracings of 61 healthy athletes (80% men, median age 23 ± 8 years), showing "domed" ST-segment elevation and negative T wave in leads V1 to V3, with those of 92 consecutive age- and sex-matched BS patients with a "coved-type" electrocardiographic pattern. The electrocardiographic analysis focused on the ST-segment elevation at J point (STJ) and at 80 milliseconds after J point (ST₈₀). Athletes had a lower maximum amplitude of STJ (1.46 ± 0.7 vs 3.25 ± 0.6 mm, p 1) versus only 2 (3%) athletes (p <0.001). An upsloping ST-segment configuration (STJ/ST₈₀ <1) showed a sensitivity of 97%, a specificity of 100%, and a diagnostic accuracy of 98.7% for the diagnosis of ER. At multivariate analysis, STJ/ST₈₀ ratio remained the only independent predictor for ER (odds ratio 87, 95% confidence interval 19 to 357, p <0.001). In conclusion, the STJ/ST₈₀ ratio is a highly accurate electrocardiographic parameter for differential diagnosis between anterior ER of the athlete and BS. Our results may help in reducing the number of athletes who undergo expensive diagnostic workup or are unnecessarily disqualified from competition for changes that fall within the normal range of athlete's heart. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Electrical Signs predictors of malignant ventricular arrhythmias

    International Nuclear Information System (INIS)

    Aleman Fernandez, Ailema Amelia; Dorantes Sanchez, Margarita

    2012-01-01

    Recurrence of malignant ventricular arrhythmia is frequent in cardioverter-defibrillators related patients. The risk stratification is difficult, there are numerous electrocardiographic predictors but his sensibility and specificity are not absolute. The limit between normal and pathological is not defined, besides the complexity of ventricular arrhythmias. We expose different electrocardiographic predictors that can help to better individual risk stratification

  16. Fermented ginseng, GBCK25, ameliorates hemodynamic function on experimentally induced myocardial injury

    Directory of Open Access Journals (Sweden)

    Adithan Aravinthan

    2016-10-01

    Full Text Available In the present study, we investigated whether treatment with GBCK25 facilitated the recovery of hemodynamic parameters, left ventricle systolic pressure, left ventricular developed pressure, and electrocardiographic changes. GBCK25 significantly prevented the decrease in hemodynamic parameters and ameliorated the electrocardiographic abnormality. These results indicate that GBCK25 has distinct cardioprotective effects in rat heart.

  17. A Report of Brugada Syndrome Presenting with Cardiac Arrest Triggered by Verapamil Intoxication

    Directory of Open Access Journals (Sweden)

    Kahraman Yakut

    2017-12-01

    Full Text Available Background: Brugada syndrome is a disease characterized by a specific electrocardiographic pattern and an increased risk of sudden cardiac death. We present this case with the updated literature to emphasise the need to consider the diagnosis of Brugada syndrome in patients admitted to the emergency ward with sudden cardiac arrest. Case Report: A 16-year-old female patient was admitted to the emergency ward with complaints of weakness and abdominal pain, and she had four cardiac arrests during her evaluation period. She was referred to our clinic for permanent pacemaker implantation. She was on a temporary pace maker after having had C-reactive protein. Her physical exam was normal except for bilaterally decreased lung sounds. Lung x-ray and computed tomography, which were performed by another institution, revealed minimal pleural effusion and nothing else of significance. Blood and peritoneal fluid samples were sterile. Echocardiographic exam and cardiac enzymes were also in the normal ranges. Electrocardiographic showed incomplete right branch block in leads V1 and V2. An ajmaline test revealed specific electrocardiographic findings of the type I Brugada pattern. We proposed implanting an implantable cardioverter defibrillator to the patient as there were positive findings on the ajmaline test as well as a history of sudden cardiac arrest. After this treatment proposal, the patient’s family admitted that she had taken a high dose of verapamil and thus, the encountered bradycardia was associated with verapamil overuse. The ajmaline test was repeated as it was contemplated that the previous positive ajmaline test had been associated with verapamil overuse. Implantable cardioverter defibrillator implantation was proposed again as there was a history of sudden cardiac arrest; however, the family did not consent to implantable cardioverter defibrillator, and the patient was discharged and followed up. Conclusion: Brugada syndrome should be

  18. Wolff-Parkinson-White syndrome type B and left bundle-branch block: electrophysiologic and radionuclide study

    Energy Technology Data Exchange (ETDEWEB)

    Rakovec, P.; Kranjec, I.; Fettich, J.J.; Jakopin, J.; Fidler, V.; Turk, J.

    1985-01-01

    Coinciding left bundle-branch block and Wolff-Parkinson-White syndrome type B, a very rare electrocardiographic occurrence, was found in a patient with dilated cardiomyopathy. Electrophysiologic study revealed eccentric retrograde atrial activation during ventricular pacing, suggesting right-sided accessory pathway. At programmed atrial pacing, effective refractory period of the accessory pathway was 310 ms; at shorter pacing coupling intervals, normal atrioventricular conduction with left bundle-branch block was seen. Left bundle-branch block was seen also with His bundle pacing. Radionuclide phase imaging demonstrated right ventricular phase advance and left ventricular phase delay; both right and left ventricular phase images revealed broad phase distribution histograms. Combined electrophysiologic and radionuclide investigations are useful to disclose complex conduction abnormalities and their mechanical correlates.

  19. Wolff-Parkinson-White syndrome type B and left bundle-branch block: electrophysiologic and radionuclide study

    International Nuclear Information System (INIS)

    Rakovec, P.; Kranjec, I.; Fettich, J.J.; Jakopin, J.; Fidler, V.; Turk, J.

    1985-01-01

    Coinciding left bundle-branch block and Wolff-Parkinson-White syndrome type B, a very rare electrocardiographic occurrence, was found in a patient with dilated cardiomyopathy. Electrophysiologic study revealed eccentric retrograde atrial activation during ventricular pacing, suggesting right-sided accessory pathway. At programmed atrial pacing, effective refractory period of the accessory pathway was 310 ms; at shorter pacing coupling intervals, normal atrioventricular conduction with left bundle-branch block was seen. Left bundle-branch block was seen also with His bundle pacing. Radionuclide phase imaging demonstrated right ventricular phase advance and left ventricular phase delay; both right and left ventricular phase images revealed broad phase distribution histograms. Combined electrophysiologic and radionuclide investigations are useful to disclose complex conduction abnormalities and their mechanical correlates

  20. Padronização de parâmetros eletrocardiográficos de cães da raça Golden Retriever clinicamente sadios Standardization of electrocardiographic parameters in healthy Golden Retrievers dogs

    Directory of Open Access Journals (Sweden)

    Arine Pellegrino

    2010-12-01

    pathogenesis of DMD and of Golden Retriever muscular dystrophy allows to qualify the dog as the main substitute of humans in the clinical tests of new therapies. The deficient myocardium in distrofin is more vulnerable to the pressure overload and the patients with DMD can develop dilated cardiomyopathy, arterial hypertension and the electrocardiogram can come distinctly abnormal. In the present study, 38 healthy Golden Retriever dogs were evaluated by electrocardiographic exam with the purpose to obtain parameters for the standardization of the electrocardiogram in the referred breed, what hereafter can serve as reference in the identification of bearer or affected dogs. Electrocardiographic values obtained were within normal values and reference for the various breeds of dogs, and the variables weight and age significantly altered heart rate and amplitude of the QRS complex.

  1. Takotsubo cardiomyopathy in the case of 72-year-old teacher after work-related psychological stress. Evolution of left ventricular longitudinal strain - Delayed but complete recovery in automated function imaging (AFI).

    Science.gov (United States)

    Wierzbowska-Drabik, Karina; Marcinkiewicz, Andrzej; Hamala, Piotr; Trzos, Ewa; Lipiec, Piotr; Kurpesa, Małgorzata; Kręcki, Radosław; Plewka, Michał; Kasprzak, Jarosław D

    2017-06-19

    Takotsubo cardiomyopathy (TC) is related to a transient systolic dysfunction of left ventricle (LV), accompanied by clinical and electrocardiographic symptoms of myocardial ischemia in the absence of hemodynamically significant coronary artery disease. Takotsubo cardiomyopathy is usually provoked by a psychologically or/and physically stressful event which may be related to occupational activities. Although visually assessed evolution of LV function is well documented, the data concerning strain changes is sparse and various patterns of deformation abnormalities are suggested. We have described a 72-year-old woman with chest pain related to a lecture given at the meeting of the Senior University, fulfilling all the Mayo Clinic criteria of the TC. The longitudinal strain analysis with automated function imaging (AFI) documented severe impairment and stepwise recovery of regional and global LV contractility. The case described confirms that accurate diagnosis, treatment and documenting of functional improvement in takotsubo cardiomyopathy may enable the return to occupational activities even for elderly persons. Int J Occup Med Environ Health 2017;30(4):681-683. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  2. Influence of presenting electrocardiographic findings on the treatment and outcomes of patients with non-ST-segment elevation myocardial infarction.

    Science.gov (United States)

    Patel, Jigar H; Gupta, Raghav; Roe, Matthew T; Peng, S Andrew; Wiviott, Stephen D; Saucedo, Jorge F

    2014-01-15

    The influence of the presenting electrocardiographic (ECG) findings on the treatment and outcomes of patients with non-ST-segment elevation myocardial infarction (NSTEMI) has not been studied in contemporary practice. We analyzed the clinical characteristics, in-hospital management, and in-hospital outcomes of patients with NSTEMI in the Acute Coronary Treatment and Intervention Outcomes Network Registry-Get With The Guidelines (ACTION Registry-GWTG) according to the presenting ECG findings. A total of 175,556 patients from 485 sites from January 2007 to September 2011 were stratified by the ECG findings on presentation: ST depression (n = 40,146, 22.9%), T-wave inversions (n = 24,627, 14%), transient ST-segment elevation (n = 5,050, 2.9%), and no ischemic changes (n = 105,733, 60.2%). Patients presenting with ST-segment depression were the oldest and had the greatest prevalence of major cardiac risk factors. Coronary angiography was performed most frequently in the transient ST-segment elevation group, followed by the T-wave inversion, ST-segment depression, and no ischemic changes groups. The angiogram revealed that patients with ST-segment depression had more left main, proximal left anterior descending, and 3-vessel coronary artery disease and underwent coronary artery bypass grafting most often. In contrast, patients with transient ST-segment elevation had 1-vessel CAD and underwent percutaneous coronary intervention the most. The unadjusted mortality was highest in the ST-segment depression group, followed by the no ischemic changes, transient ST-segment elevation, and T-wave inversion group. Adjusted mortality using the ACTION Registry-GWTG in-hospital mortality model with the no ischemic changes group as the reference showed that in-hospital mortality was similar in the transient ST-segment elevation (odds ratio 1.15, 95% confidence interval 0.97 to 1.37; p = 0.10), higher in the ST-segment depression group (odds ratio 1.46, 95% confidence interval 1

  3. Takotsubo Cardiomyopathy in Intensive Care Unit: Prevention, Diagnosis and Management

    Directory of Open Access Journals (Sweden)

    Hannah Masoud

    2016-01-01

    Full Text Available Accurate diagnosis of Takotsubo Cardiomyopathy has substantial prognostic implications in an intensive care unit, given its increased mortality risk and association with life-threatening complications. This report seeks to discuss diagnostic modalities that can be useful in accurately differentiating Takotsubo Cardiomyopathy from Acute Coronary Syndrome, and also briefly discuss prevention and management of this cardiomyopathy in an intensive care unit. For critically ill Takotsubo patients, intensive clinicians can consider establishment of diagnosis by specific electrocardiograph changes, distinctive marked release of cardiac enzymes, characteristic echocardiograph findings, as well as invasive coronary angiography or noninvasive cardiac magnetic imaging.

  4. Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Li Shuo; Gao Song; Wang Lei; Zhu Yan-Chun; Yang Jie; Xie Yao-Qin; Fu Nan; Wang Yi

    2016-01-01

    Conventional multiple breath-hold two-dimensional (2D) balanced steady-state free precession (SSFP) presents many difficulties in cardiac cine magnetic resonance imaging (MRI). Recently, a self-gated free-breathing three-dimensional (3D) SSFP technique has been proposed as an alternative in many studies. However, the accuracy and effectiveness of self-gating signals have been barely studied before. Since self-gating signals are crucially important in image reconstruction, a systematic study of self-gating signals and comparison with external monitored signals are needed.Previously developed self-gated free-breathing 3D SSFP techniques are used on twenty-eight healthy volunteers. Both electrocardiographic (ECG) and respiratory bellow signals are also acquired during the scan as external signals. Self-gating signal and external signal are compared by trigger and gating window. Gating window is proposed to evaluate the accuracy and effectiveness of respiratory self-gating signal. Relative deviation of the trigger and root-mean-square-deviation of the cycle duration are calculated. A two-tailed paired t-test is used to identify the difference between self-gating and external signals. A Wilcoxon signed rank test is used to identify the difference between peak and valley self-gating triggers.The results demonstrate an excellent correlation ( P = 0, R > 0.99) between self-gating and external triggers. Wilcoxon signed rank test shows that there is no significant difference between peak and valley self-gating triggers for both cardiac ( H = 0, P > 0.10) and respiratory ( H = 0, P > 0.44) motions. The difference between self-gating and externally monitored signals is not significant (two-tailed paired-sample t-test: H = 0, P > 0.90).The self-gating signals could demonstrate cardiac and respiratory motion accurately and effectively as ECG and respiratory bellow. The difference between the two methods is not significant and can be explained. Furthermore, few ECG trigger errors

  5. Acute anterior myocardial infarction seen on conventional iodine-contrast CT

    Directory of Open Access Journals (Sweden)

    Christian Hagdrup, MD

    2017-09-01

    Full Text Available Diagnosis of acute myocardial infarction (AMI is based on clinical symptoms of chest pain and dyspnea in combination with electrocardiographic changes and a raise in myocardial-specific biomarkers. Imaging is by echocardiography and magnetic resonance. The preferred technique for identification of previous myocardial infarction (MI is magnetic resonance imaging with late gadolinium technique, but in the acute patient echocardiography is applied. In selected cases, important information can be obtained from other imaging modalities. We describe a case of a patient first suspected of an abdominal catastrophe in whom acute MI was diagnosed from a computerized tomography (CT scan with iodine contrast. Our case together with a few other cases reported in the literature demonstrate that contrast enhancement of the myocardium can be important to follow in the acute patient because the CT scans sometimes give a unique opportunity to recognize findings consistent with MI even though the CT scan was performed for another reason.

  6. Clinical evaluation of 99mTc-CPI myocardial perfusion single photon emission computerized tomography in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Peng Changping

    1991-01-01

    Two normal subjects, 5 patients with old myocardial infarction (OMI) and 4 patients with angina pectoris were examined by rest single photon emission computerized tomography revealed that the right ventricular was not imaged, the left ventricular was well exposed in the normal subjects. All the 9 patients had defects in the left ventricle. comparison of SPECT with 99m Tc-CPI with selective coronary arteriography (SCA), echocardiography (UCG), dynamic electrocardiography (DCG) and electrocardiographic (ECG)-exercise test in the diagnosis of myocardial ischemia or necrosis has demonstrated the former to be more significantly sensitive than the latter four. Good agreement between SPECT and SCA has been confirmed

  7. Precordial ST-segment depression during acute inferior myocardial infarction: clinical, scintigraphic and angiographic correlations

    International Nuclear Information System (INIS)

    Gibson, R.S.; Crampton, R.S.; Watson, D.D.; Taylor, G.J.; Carabello, B.A.; Holt, N.D.; Beller, G.A.

    1982-01-01

    The cause and associated pathophysiology of precordial ST-segment depression during acute inferior myocardial infarction (IMI) are controversial. To investigate this problem, electrocardiographic findings in 48 consecutive patients with acute IMI were prospectively compared with results of coronary angiography, submaximal exercise thallium-201 ( 201 Tl) scintigraphy and multigated blood pool imaging, all obtained 2 weeks after IMI, and with clinical follow-up at 3 months. Patients were classified according to the admission ECG obtained 3.3 +/- 3.1 hours after the onset of chest pain. Twenty-one patients (group A) had no or 201 Tl perfusion abnormalities (p 201 Tl defects or wall motion abnormalities in anterior or septal segments

  8. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome. Assessment by radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko and others

    1989-04-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author).

  9. Phase analysis of regional and global ventricular contraction patterns in Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Koyama, Takao; Ichikawa, Takehiko

    1989-01-01

    Multigated blood pool scintigraphy was performed in 20 normal subjects and 39 patients with various intraventricular conduction abnormalities, including 25 patients with Wolff-Parkinson-White (WPW) syndrome. Cardiac imaging was performed in the modified left anterior oblique, right anterior oblique, and left lateral projections. In WPW syndrome, early contraction sites which were not seen in normal subjects were detected at the ventricular base in phase images. These anomalous early contraction sites disappeared after successful suppression of conduction through an accessory pathway by intravenous procainamide. These sites are believed to correspond to the location of the bundle of Kent and were consistent with the electrocardiographic findings. Phase mapping is a suitable noninvasive method to locate the position of the bundle of Kent and evaluate the ventricular contraction pattern in WPW syndrome and other intraventricular conduction abnormalities. (author)

  10. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-01-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary

  11. Mitral valve prolapse in the ventriculogram: scintigraphic, electrocardiographic, and hemodynamic abnormalities

    International Nuclear Information System (INIS)

    Tebbe, U.; Schicha, H.; Neumann, P.; Voth, E.; Emrich, D.; Neuhaus, K.L.; Kreuzer, H.

    1985-01-01

    Patients with mitral valve prolapse (MVP) frequently have chest pain, which may be difficult to differentiate from angina pectoris in coronary artery disease (CAD). The authors performed resting and exercise ECGs, pulmonary arterial pressure measurements, radionuclide ventriculography (/sup 99m/technetium), and perfusion scintigrams ( 201 thallium) in 56 patients with angiographically proven MVP and no CAD. Pathological results were obtained in 31% of exercise ECGs, 33% of pulmonary arterial pressure measurements during exercise, 22% of radionuclide ventriculographies, and in 75% of thallium perfusion scintigrams. A significant correlation in pathological results was found only between exercise ECG and both radionuclide ventriculography and pulmonary arterial pressure measurements. Because of the high prevalence of false-positive perfusion scintigrams in patients with typical or atypical chest pain, the use of exercise 201 Tl imaging as a screening method to separate patients with MVP from those with CAD will not be appropriate. The variability of cardiac abnormalities in our patients with MVP and angiographically normal coronary arteries suggests that the MVP syndrome may represent a variable combination of metabolic, ischemic, or myopathic disorders

  12. Alternative diagnostic strategies for coronary artery disease in women: demonstration of the usefulness and efficiency of probability analysis

    International Nuclear Information System (INIS)

    Melin, J.A.; Wijns, W.; Vanbutsele, R.J.; Robert, A.; De Coster, P.; Brasseur, L.A.; Beckers, C.; Detry, J.M.

    1985-01-01

    Alternative strategies using conditional probability analysis for the diagnosis of coronary artery disease (CAD) were examined in 93 infarct-free women presenting with chest pain. Another group of 42 consecutive female patients was prospectively analyzed. For this latter group, the physician had access to the pretest and posttest probability of CAD before coronary angiography. These 135 women all underwent stress electrocardiographic, thallium scintigraphic, and coronary angiographic examination. The pretest and posttest probabilities of coronary disease were derived from a computerized Bayesian algorithm. Probability estimates were calculated by the four following hypothetical strategies: SO, in which history, including risk factors, was considered; S1, in which history and stress electrocardiographic results were considered; S2, in which history and stress electrocardiographic and stress thallium scintigraphic results were considered; and S3, in which history and stress electrocardiographic results were used, but in which stress scintigraphic results were considered only if the poststress probability of CAD was between 10% and 90%, i.e., if a sufficient level of diagnostic certainty could not be obtained with the electrocardiographic results alone. The strategies were compared with respect to accuracy with the coronary angiogram as the standard. For both groups of women, S2 and S3 were found to be the most accurate in predicting the presence or absence of coronary disease (p less than .05). However, it was found with use of S3 that more than one-third of the thallium scintigrams could have been avoided without loss of accuracy. It was also found that diagnostic catheterization performed to exclude CAD as a diagnosis could have been avoided in half of the patients without loss of accuracy.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. ANÁLISIS ELECTROCARDIOGRÁFICO DE LA DISPERSIÓN DEL INTERVALO TPICO-TFINAL EN EL INFARTO AGUDO DE MIOCARDIO CON ELEVACIÓN DEL ST / Electrocardiographic analysis of the T peak-T end interval dispersion in acute myocardial infarction with ST-segment elevation

    Directory of Open Access Journals (Sweden)

    Raimundo Carmona Puerta

    2010-09-01

    Full Text Available Resumen Introducción y objetivos: La dispersión del intervalo TPICO-TFINAL (Tpeak-Tend constituye una novedosa variable electrocardiográfica asociada recientemente, al riesgo de arritmias ventriculares malignas en el síndrome de Brugada, pero apenas se ha estudiado en el infarto agudo de miocardio con elevación del segmento ST, por lo que se decidió analizarlo en este contexto. Métodos: Se realizó un estudio de corte transversal donde se compararon los electrocardiogramas de 37 pacientes con infarto con elevación del segmento ST y otros 37, supuestamente sanos con respecto a las variables electrocardiográficas que evalúan la repolarización ventricular. Resultados: Se encontraron diferencias altamente significativas (p<0,001 al comparar a los pacientes infartados (QT 416,9 ± 42,3; QTc 431,4 ± 36,2 con los sanos (QT 441,2 ± 57,4 y QTc 477,6 ± 58,5, y significativas (p < 0,05 en la TPICO-TFINAL (37.2 ms vs. 21,6 ms. Existió correlación significativa entre el QT y la TPICO-TFINAL en el IMACEST inferior y ántero-septal, la que fue doblemente intensa en la localización ántero-septal (r = 0,34 vs. r = 0,80. Conclusiones: La dispersión del intervalo TPICO-TFINAL fue significativamente mayor en pacientes con infarto agudo de miocardio con elevación del segmento ST, independientemente de la localización del infarto. / Abstract Introduction and objectives: Tpeak-Tend interval dispersion is a new electrocardiographic variable recently associated to the risk of malignant ventricular arrhythmias in Brugada syndrome but it has hardly been studied in the acute myocardial infarction with ST-segment elevation. That is why it was analyzed in this context. Methods: A cross-sectional study was carried out in which the electrocardiograms of 37 patients with ST-segment elevation myocardial infarctions and other 37 apparently healthy patients (regarding electrocardiographic variables that assess ventricular repolarization were compared. Results

  14. Utility of 12-lead electrocardiogram for differentiating paroxysmal supraventricular tachycardias in dogs.

    Science.gov (United States)

    Santilli, R A; Perego, M; Crosara, S; Gardini, F; Bellino, C; Moretti, P; Spadacini, G

    2008-01-01

    The 12-lead surface ECG is validated for differentiating supraventricular tachycardias (SVT) in humans. Despite the description of SVT in veterinary medicine, no studies have analyzed the electrocardiographic features of this type of arrhythmias in dogs. To describe the specific electrocardiographic criteria used to differentiate the most common SVT in dogs. Twenty-three dogs examined at Clinica Veterinaria Malpensa for SVT with the mechanism documented by electrophysiologic studies (EPS). Twelve-lead electrocardiographic variables obtained from 14 dogs with orthodromic atrioventricular reciprocating tachycardia (OAVRT) and 9 dogs with focal atrial tachycardia (FAT) were compared. Dogs with FAT had faster heart rates (278 +/- 62 versus 229 +/- 42 bpm; P= .049) and less QRS alternans (33 versus 86%; P= .022). P waves appeared during tachycardia in 22 dogs, with a superior axis in 100% of OAVRT and 22% of FAT (P < .001). OAVRT was characterized by a shorter RP interval (85.0 +/- 16.8 versus 157.1 +/- 37.3 ms; P < .001) and smaller RP/PR ratio (0.60 +/- 0.18 versus 1.45 +/- 0.52; P < .001). Repolarization anomalies were present in 64% of OAVRT and no FAT (P < .001). Multivariate analysis identified QRS alternans and a positive P wave in aVR during tachycardia as independent predictors of arrhythmia type. Electrocardiographic criteria used in people for differentiating SVT can also be applied in dogs.

  15. Clinical and electrocardiographic characteristics of patients admitted to a thoracic pain unit in the context of a new definition of acute myocardial infarction; Caracteristicas clinicas y electrocardiograficas de los pacientes que ingresan a una unidad de dolor toracico en el contexto de la nueva definicion de infarto agudo de miocardio

    Energy Technology Data Exchange (ETDEWEB)

    Mora, Guillermo; Franco, Roberto; Fajardo, Hugo; Serrano, Daniel; Suarez, Martin

    2005-03-15

    In our environment we do ignore the clinical and para clinical characteristics from patients who come to a thoracic pain unit and more so with the new definition of acute myocardial infarction (Amid). 398 patients admitted to a thoracic pain unit were prospectively evaluated as to the pain characteristics, its risk factors, clinical examination findings, electrocardiographic findings and the troponin a T behaviour. 29.4% of the patients had a diagnosis of Amid, 29.9% of unstable angina and 40.7% of non-ischemic thoracic pain. retrosternal pain, irradiation to the neck, presence of diaphoresis, nausea or vomit are related with a higher probability to the diagnosis of Amid. Male sex and the presence of risk factors such as diabetes or dislipidemia increase the probability of the diagnosis. In the electrocardiogram, only the presence of a lesion, especially subepicardical favors the diagnosis. Unstable angina and in general acute coronary syndrome have a similar although not equal clinical behavior.

  16. Chronic valvular disease: correlation between clinical, electrocardiographic, radiographic and echocardiographic aspects in dogs Doença valvar crônica: correlação entre aspectos clínicos, eletrocardiográficos, radiográficos e ecocardiográficos em cães

    Directory of Open Access Journals (Sweden)

    E.C. Soares

    2005-08-01

    Full Text Available Echocardiographic aspects of chronic mitral valvular disease were studied and compared to physical, radiographic and electrocardiographic aspects. Seventy dogs were used, and clinical examination, thoracic radiography, electrocardiogram and echocardiogram were performed. Correlations between regurgitation severity with cardiac failure functional class and murmur intensity were observed. The electrocardiogram showed a low sensibility in detecting cardiac chamber enlargement, caused by mitral regurgitation. All the dogs with severe mitral regurgitation showed cardiomegaly according to thoracic radiographies.Avaliaram-se os aspectos ecocardiográficos da doença valvar crônica, comparando-os com os aspectos clínicos, radiográficos e eletrocardiográficos em cães. Estudaram-se 70 animais, realizando-se exames físicos, radiografias torácicas, eletrocardiograma e ecocardiograma. Observaram-se correlações entre a gravidade da regurgitação, a classe funcional da insuficiência cardíaca e a intensidade de sopro. O eletrocardiograma mostrou baixa sensibilidade para detectar aumento de câmaras cardíacas causadas por regurgitação mitral. Todos os cães com regurgitação mitral grave apresentaram cardiomegalia nas radiografias torácicas.

  17. Chest Pain with Normal Thallium-201 Myocardial Perfusion Image – Is It Really Normal?

    Science.gov (United States)

    Liu, Pang-Yen; Lin, Wen-Yu; Lin, Li-Fan; Lin, Chin-Sheng; Lin, Wei-Shiang; Cheng, Shu-Meng; Yang, Shih-Ping; Liou, Jun-Ting

    2016-01-01

    Background Thallium-201 myocardial perfusion image (MPI) is commonly used to detect coronary artery disease in patients with chest pain. Although a normal thallium-201 MPI result is generally considered to be a good prognosis and further coronary angiogram is not recommended, there are still a few patients who suffer from unexpected acute coronary events. The aim of this study was to investigate the clinical prognosis in patients with normal thallium-201 MPI. Methods From January 2006 to August 2012, a total 22,003 patients undergoing thallium-201 MPI in one tertiary center were screened. Of these, 8092 patients had normal results and were investigated retrospectively. During follow-up, 54 patients underwent coronary angiogram because of refractory typical angina pectoris or unexpected acute coronary events. These 54 patients were divided into 2 groups: group I consisted of 26 (48.1%) patients with angiography-proven significant coronary artery stenosis, and group II consisted of 28 (51.9%) patients without significant stenosis. Results Patients in group I had a higher prevalence of prior coronary stenting and electrocardiographic features of ST depression compared with patients in group II. The multivariate analysis demonstrated that both prior coronary stenting and ST depression were risk predictors of unexpected acute coronary events in the patients with normal thallium-201 MPI [odds ratio (OR), 5.93; 95% confidence interval (CI): 1.03-34.06, p = 0.05 and OR, 7.10; 95% CI: 1.28-39.51, p = 0.03,respectively]. Conclusions Although there is a low incidence of unexpected acute coronary events in patients with chest pain and normal thallium-201 MPI, physicians should be aware of the potentials risk in certain patients in this specific population. PMID:27274174

  18. Association of Implementation of Practice Standards for Electrocardiographic Monitoring with Nurses’ Knowledge, Quality of Care, and Patient Outcomes: Findings from the Practical Use of the Latest Standards of Electrocardiography (PULSE) Trial

    Science.gov (United States)

    Funk, Marjorie; Fennie, Kristopher P.; Stephens, Kimberly E.; May, Jeanine L.; Winkler, Catherine G.; Drew, Barbara J.

    2017-01-01

    Background Although continuous electrocardiographic (ECG) monitoring is ubiquitous in hospitals, monitoring practices are inconsistent. We evaluated implementation of American Heart Association practice standards for ECG monitoring on nurses’ knowledge, quality of care, and patient outcomes. Methods and Results The PULSE Trial was a 6-year multi-site randomized clinical trial with crossover that took place in 65 cardiac units in 17 hospitals. We measured outcomes at baseline, Time 2 after Group 1 hospitals received the intervention, and Time 3 after Group 2 hospitals received the intervention. Measurement periods were 15 months apart. The 2-part intervention consisted of an online ECG monitoring education program and strategies to implement and sustain change in practice. Nurses’ knowledge (N=3,013 nurses) was measured by a validated 20-item online test, quality of care related to ECG monitoring (N=4,587 patients) by on-site observation, and patient outcomes (mortality, in-hospital myocardial infarction, and not surviving a cardiac arrest) (N=95,884 hospital admissions) by review of administrative, laboratory, and medical record data. Nurses’ knowledge improved significantly immediately following the intervention in both groups, but was not sustained 15 months later. For most measures of quality of care (accurate electrode placement, accurate rhythm interpretation, appropriate monitoring, and ST-segment monitoring when indicated), the intervention was associated with significant improvement, which was sustained 15 months later. Of the 3 patient outcomes, only in-hospital myocardial infarction declined significantly after the intervention, and was sustained. Conclusions Online ECG monitoring education and strategies to change practice can lead to improved nurses’ knowledge, quality of care, and patient outcomes. PMID:28174175

  19. Clinical evaluation of myocardial involvement in acute myopericarditis in young adults.

    Science.gov (United States)

    Saricam, Ersin; Saglam, Yasemin; Hazirolan, Tuncay

    2017-05-22

    Myocardial involvement in young adults has various causes. Acute myopericarditis is one of the myocardial involvements in young adults. It is easy to confuse with acute ST-elevation myocardial infarction because of the electrocardiographic features. This study aims to investigate a number of imaging techniques and clinical features for acute myopericarditis in young adults (defined as myocardial brightness in the left ventricle regions, especially in posterior and lateral wall. Focal echobright was observed in the 75 of 77 cases of acute myopericarditis in transthoracic echocardiogram. This sign was confirmed by cardiac magnetic resonance imaging. Focal echobright sensitivity was 95%; its specificity was 93%; its predictive was 95.2%. Pericardial effusion (83%) was observed in group I behind posterior wall. Its specificity was 81%; its sensitivity was 65%; predictivity was 73%. Pericardial effusion and myocardial focal echobright in echocardiography can be quite sensitive indicators for acute myopericarditis in young adults.

  20. A simplified approach for evaluating multiple test outcomes and multiple disease states in relation to the exercise thallium-201 stress test in suspected coronary artery disease

    International Nuclear Information System (INIS)

    Pollock, S.G.; Watson, D.D.; Gibson, R.S.; Beller, G.A.; Kaul, S.

    1989-01-01

    This study describes a simplified approach for the interpretation of electrocardiographic and thallium-201 imaging data derived from the same patient during exercise. The 383 patients in this study had also undergone selective coronary arteriography within 3 months of the exercise test. This matrix approach allows for multiple test outcomes (both tests positive, both negative, 1 test positive and 1 negative) and multiple disease states (no coronary artery disease vs 1-vessel vs multivessel coronary artery disease). Because this approach analyzes the results of 2 test outcomes simultaneously rather than serially, it also negates the lack of test independence, if such an effect is present. It is also demonstrated that ST-segment depression on the electrocardiogram and defects on initial thallium-201 images provide conditionally independent information regarding the presence of coronary artery disease in patients without prior myocardial infarction. In contrast, ST-segment depression on the electrocardiogram and redistribution on the delayed thallium-201 images may not provide totally independent information regarding the presence of exercise-induced ischemia in patients with or without myocardial infarction

  1. Usefulness of multimodality imaging for detection of myocardial infarction in patients with advanced kidney failure: case report

    Energy Technology Data Exchange (ETDEWEB)

    Veras, Mariana Ferreira; Azevedo, Jader Cunha de; Gamarski, Moisés; Mesquita, Evandro Tinoco; Mesquita, Cláudio Tinoco, E-mail: fvmari@gmail.com [Hospital Procardíaco, Rio de Janeiro, RJ (Brazil); Alves, José Galvão [Centro Universitário de Volta Redonda, RJ (Brazil)

    2016-01-15

    The third universal definition of acute myocardial infarction (AMI) is based on the elevation of troponin in association with ischemic symptoms, electrocardiographic changes and imaging findings. In patients with chest pain, the diagnosis of AMI is performed by dosing serum markers of myocardial necrosis, particularly troponins, by means of changes in 12 - lead electrocardiogram (ECG) or by identifying changes in the contractile dynamics of the left ventricle to the transthoracic echocardiogram. In some cases, confounding factors may hamper the diagnosis, such as: (a) presence of previous changes in the baseline ECG, especially LBBB; (b) elevations of myocardial necrosis markers (MNM) resulting from situations other than AMI and; (c) old changes in contractility detected by transthoracic ECG. Serum cardiac troponin (Tn) is the most specific and most used MNM for the diagnosis of AMI. Nevertheless, in some situations troponin elevation may not be due to an AMI, as in cases of acute pulmonary embolism, acute pericarditis, severe heart failure, myocarditis, and sepsis and kidney failure. Patients with kidney failure have high probability of concurrent cardiovascular disease. Furthermore, the cross-reacting proteins interfering with skeletal muscle, analytical imprecision and interactions with the dialysis membrane may cause elevation of troponin in 7% to 17% of patients with kidney failure. When in doubt about diagnosis of AMI, {sup 99m}Technetium pyrophosphate myocardial scintigraphy ({sup 99m}Tc-PYP) stands out as a noninvasive method capable of identifying areas of myocardial necrosis, thus helping in the diagnosis of AMI. {sup 99m}Tc-labeled phosphonate agents undergo chemical absorption with calcium. A large influx of calcium occurs during the evolutionary process of AMI. The calcium flows into the intracellular space and myocardial concentration of {sup 99m}Tc-PYP follows such increase, with a maximum peak uptake about 48 to 72 hours after the acute event. The

  2. Spinal imaging and image analysis

    CERN Document Server

    Yao, Jianhua

    2015-01-01

    This book is instrumental to building a bridge between scientists and clinicians in the field of spine imaging by introducing state-of-the-art computational methods in the context of clinical applications.  Spine imaging via computed tomography, magnetic resonance imaging, and other radiologic imaging modalities, is essential for noninvasively visualizing and assessing spinal pathology. Computational methods support and enhance the physician’s ability to utilize these imaging techniques for diagnosis, non-invasive treatment, and intervention in clinical practice. Chapters cover a broad range of topics encompassing radiological imaging modalities, clinical imaging applications for common spine diseases, image processing, computer-aided diagnosis, quantitative analysis, data reconstruction and visualization, statistical modeling, image-guided spine intervention, and robotic surgery. This volume serves a broad audience as  contributions were written by both clinicians and researchers, which reflects the inte...

  3. Computed tomographic, electrocardiographic and clinical investigations in patients with ischemic strokes

    International Nuclear Information System (INIS)

    Manchev, L.; Mitev, M.; Milanova, V.; Zafirova, E.; Manolova, T.; Manchev, I.; Toneva, J.

    2013-01-01

    The Computed Tomography (CT) is a widely available and reliable method for the diagnosis of cerebrovascular disease. It allows in the first hours of the occurrence of vascular events to be established the type of brain stroke and creates conditions for timely fibrinolytic or surgical treatment. In many cases where it cannot be performed echocardiographic examination modern electrocardiography (ECG) makes it possible to demonstrate the presence of cardiac disease. These two methods in combination with neurological status create conditions for determining the treatment strategy for ischemic brain stroke (IBS). We studied 222 patients (92 men and 110 women with a middle age 59.7 years) selected randomized. At a computed tomography study in the early hours of IBS were found pathological findings in 115 patients (51.8%) slightly more often in women. IBS in the carotid system were greatly predominant in comparison with those in the vertebrobasilar system (VBS), which can be explained with the blood flow to the brain stem. When ECG is most commonly met diagnosis: hypertension HSSN 111 stage II - III functional class NYUHA, ischemic cardiomyopathy in 64 patients overall, with almost equal frequency in men 30 (17.5%) and women - 34 (19.8%). In neurological examination significantly predominant clinical symptoms karoditnata vasculature, in 154 patients (69.3%) compared to that of the VBS- 68 (30.7%). Fulfilled study shows the need for better coordination of the activities of specialists in diagnostic imaging and neurologists for their work in specialized hospitals (Stroke Units). (authors)

  4. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  5. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  6. Speckle imaging algorithms for planetary imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    I will discuss the speckle imaging algorithms used to process images of the impact sites of the collision of comet Shoemaker-Levy 9 with Jupiter. The algorithms use a phase retrieval process based on the average bispectrum of the speckle image data. High resolution images are produced by estimating the Fourier magnitude and Fourier phase of the image separately, then combining them and inverse transforming to achieve the final result. I will show raw speckle image data and high-resolution image reconstructions from our recent experiment at Lick Observatory.

  7. Maximal exercise capacity is related to cardiovascular structure in patients with longstanding hypertension. A LIFE substudy. Losartan Intervention For Endpoint-Reduction in Hypertension

    DEFF Research Database (Denmark)

    Olsen, M H; Wachtell, K; Hermann, K L

    2001-01-01

    BACKGROUND: Cardiovascular hypertrophy and remodeling in patients with never-treated hypertension has been associated with impaired exercise capacity, but whether this relationship remains in patients with longstanding hypertension and target organ damage is less elucidated. METHODS: In 43...... unmedicated patients with essential hypertension and electrocardiographic left ventricular (LV) hypertrophy, we measured maximal workload and oxygen reserve by bicycle test, 24-h ambulatory blood pressure (BP), LV mass index by magnetic resonance imaging (LVMI(MRI), n = 31), LVMI(echo) and systemic vascular...... compliance by echocardiography, minimal forearm vascular resistance (MFVR) by plethysmography, and intima media thickness and distensibility in the common carotid arteries by ultrasound. RESULTS: The patients did not achieve the maximal workload as predicted by age, gender and body composition (146...

  8. Electrocardiographic and scintigraphic evaluation of patients with subclinical hyperthyroidism during workout.

    Science.gov (United States)

    Kaminski, Grzegorz; Dziuk, Mirosław; Szczepanek-Parulska, Ewelina; Zybek-Kocik, Ariadna; Ruchala, Marek

    2016-08-01

    Subclinical hyperthyroidism (sHT) was found to be associated with elevated heart rate, blood pressure and increased risk of extrasystoles. However, the full clinical relevance of morphological and functional implications of sHT on the cardiovascular system is still a matter of debate. The aim of the study was to prospectively assess the influence of endogenous sHT on exercise capacity and cardiac function during workout with the use of exercise electrocardiography (ExECG) and perfusion scintigraphy. The studied group consisted of 44 consecutively recruited patients diagnosed with sHT. In all patients, ExECG, followed by post-exercise myocardial perfusion imaging, was performed. Both ExECG and scintigraphy were performed twice-in the state of sHT and after euthyroidism was restored. An average time period of exercise test was significantly longer in the state of euthyroidism than in sHT. An average oxygen consumption during exercise test was also higher after euthyroidism was achieved when compared to sHT. The end-diastolic and end-systolic volume indexes, stroke volume index and cardiac index were significantly larger in patients with sHT if compared values achieved after euthyroidism restoration. Stroke volume index was negatively correlated with TSH, and positively with free thyroid hormones values in the state of sHT, before euthyroidism was achieved. Cardiac index was positively correlated with free thyroid hormones levels. The obtained results indicate worse physical capacity in subjects with sHT and improvement of several parameters assessed during ExECG and perfusion scintiscan after therapy. Observed changes might reflect the mechanism of the deleterious effect exerted by sHT on the heart.

  9. 哈氏弧菌EcGY020401优化培养%Optimization Culture of Vibrio harveyi EcGY020401

    Institute of Scientific and Technical Information of China (English)

    陶家发; 赖迎迢; 潘厚军; 石存斌; 吴淑勤

    2010-01-01

    目的:为规模化制备弧菌疫苗提供相关数据.方法:利用摇瓶和小型发酵罐培养,通过平板计数测定培养菌液的活菌数.结果:哈氏弧菌(Vibrio harveyi)EcGY020401株最适盐度为20~25g/L,合适的pH为7.5~7.7,葡萄糖浓度最适浓度为2~5g/L,用TSB优化培养基:胰蛋白胨5g/L、蛋白胨15g/L、大豆蛋白胨3g/L、酵母膏1g/L、葡萄糖4g/L、磷酸氢二钾5g/L、氯化钠15g/L、pH 7.5,培养EcGY020401菌株,可达2.95×1010 cfu/mL;小型发酵罐培养,10h可达到生长最大值,菌液浓度为3.46×1010cfu/mL 结论:用优化TSB培养基,采用发酵罐培养弧菌,可降低成本,提搞培养效率.

  10. Cardiovascular events in Japanese asymptomatic patients with type 2 diabetes: a 1-year interim report of a J-ACCESS 2 investigation using myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Kenichi [Kanazawa University Hospital, Department of Nuclear Medicine, Kanazawa (Japan); Yamasaki, Yoshimitsu [Osaka University, Center for Advanced Science and Innovation, Osaka (Japan); Kusuoka, Hideo [National Hospital Organization Osaka National Hospital, Osaka (Japan); Izumi, Tohru [Kitasato University, Department of Cardiology and Internal Medicine, Sagamihara (Japan); Kashiwagi, Atsunori [Shiga University of Medical Science, Department of Medicine, Ohtsu (Japan); Kawamori, Ryuzo [Juntendo University, Department of Medicine, Metabolism and Endocrinology, School of Medicine, Tokyo (Japan); Shimamoto, Kazuaki [Sapporo Medical University School of Medicine, Second Department of Internal Medicine, Sapporo (Japan); Yamada, Nobuhiro [University of Tsukuba, Division of Metabolism and Endocrinology, Department of Internal Medicine, Faculty of Medicine, Tsukuba (Japan); Nishimura, Tsunehiko [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science, 465 Kajii-cho, Kawara-machi, Hirokoji, Kamigyo-ku, Kyoto (Japan)

    2009-12-15

    Diabetic patients have a high risk for cardiovascular events. The role of myocardial perfusion imaging was investigated in asymptomatic diabetic patients to evaluate short-term prognosis in a Japanese population. A total of 506 asymptomatic patients {>=}50 years of age who had carotid artery maximum intima-media thickness {>=}1.1 mm, urinary albumin excretion of {>=}30 mg/g creatinine, with additional criteria of abdominal obesity, low HDL cholesterol, high triglyceride level, and hypertension were enrolled and followed up over a 3-year period. Gated SPECT with stress-rest protocol was performed and analyzed by summed defect scores and QGS software. One-year cardiovascular events were analyzed. Myocardial ischemia was observed in 17% of patients, and abnormal perfusion findings of ischemia and/or scar were observed in 32% of patients. By the end of the 1-year follow-up, 33 (6.5%) cardiovascular events occurred including 6 all-cause deaths. Patients with summed stress score (SSS) >8 had a higher incidence of either death or cardiovascular events. Event-free survival rates for SSS 0-3, 4-8, 9-13, and {>=}14 were 0.96, 0.95, 0.82, and 0.76, respectively. Multivariate Cox regression analysis showed that significant variables were SSS, history of cerebrovascular accident, and electrocardiographic abnormality at rest. The 1-year interim summary showed that cardiovascular events were significantly higher in patients with SPECT abnormality, although hard cardiac event rate was relatively low. Targeted treatment strategy is required for asymptomatic but potentially high-risk diabetic patients. (orig.)

  11. Cardiovascular events in Japanese asymptomatic patients with type 2 diabetes: a 1-year interim report of a J-ACCESS 2 investigation using myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Yamasaki, Yoshimitsu; Kusuoka, Hideo; Izumi, Tohru; Kashiwagi, Atsunori; Kawamori, Ryuzo; Shimamoto, Kazuaki; Yamada, Nobuhiro; Nishimura, Tsunehiko

    2009-01-01

    Diabetic patients have a high risk for cardiovascular events. The role of myocardial perfusion imaging was investigated in asymptomatic diabetic patients to evaluate short-term prognosis in a Japanese population. A total of 506 asymptomatic patients ≥50 years of age who had carotid artery maximum intima-media thickness ≥1.1 mm, urinary albumin excretion of ≥30 mg/g creatinine, with additional criteria of abdominal obesity, low HDL cholesterol, high triglyceride level, and hypertension were enrolled and followed up over a 3-year period. Gated SPECT with stress-rest protocol was performed and analyzed by summed defect scores and QGS software. One-year cardiovascular events were analyzed. Myocardial ischemia was observed in 17% of patients, and abnormal perfusion findings of ischemia and/or scar were observed in 32% of patients. By the end of the 1-year follow-up, 33 (6.5%) cardiovascular events occurred including 6 all-cause deaths. Patients with summed stress score (SSS) >8 had a higher incidence of either death or cardiovascular events. Event-free survival rates for SSS 0-3, 4-8, 9-13, and ≥14 were 0.96, 0.95, 0.82, and 0.76, respectively. Multivariate Cox regression analysis showed that significant variables were SSS, history of cerebrovascular accident, and electrocardiographic abnormality at rest. The 1-year interim summary showed that cardiovascular events were significantly higher in patients with SPECT abnormality, although hard cardiac event rate was relatively low. Targeted treatment strategy is required for asymptomatic but potentially high-risk diabetic patients. (orig.)

  12. United States national prevalence of electrocardiographic abnormalities in black and white middle-age (45- to 64-Year) and older (≥65-Year) adults (from the Reasons for Geographic and Racial Differences in Stroke Study).

    Science.gov (United States)

    Prineas, Ronald J; Le, Anh; Soliman, Elsayed Z; Zhang, Zhu-Ming; Howard, Virginia J; Ostchega, Yechiam; Howard, George

    2012-04-15

    A United States national sample of 20,962 participants (57% women, 44% blacks) from the Reasons for Geographic and Racial Differences in Stroke (REGARDS) study provided general population estimates for electrocardiographic (ECG) abnormalities among black and white men and women. The participants were recruited from 2003 to 2007 by random selection from a commercially available nationwide list, with oversampling of blacks and those from the stroke belt, with a cooperation rate of 49%. The measurement of risk factors and 12-lead electrocardiograms (centrally coded using Minnesota code criteria) showed 28% had ≥1 major ECG abnormality. The prevalence of abnormalities was greater (≥35%) for those ≥65 years old, with no differences between blacks and whites. However, among men <65 years, blacks had more major abnormalities than whites, most notably for atrial fibrillation, major Q waves, and left ventricular hypertrophy. Men generally had more ECG abnormalities than women. The most common ECG abnormalities were T-wave abnormalities. The average heart rate-corrected QT interval was longer in women than in men, similar in whites and blacks, and increased with age. However, the average heart rate was greater in women than in men and in blacks than in whites and decreased with age. The prevalence of ECG abnormalities was related to the presence of hypertension, diabetes, blood pressure, and age. In conclusion, black men and women in the United States have a significantly greater prevalence of ECG abnormalities than white men and women at age 45 to 64 years; however, these proportions, although larger, tended to equalize or reverse after age 65. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Retinal Imaging and Image Analysis

    Science.gov (United States)

    Abràmoff, Michael D.; Garvin, Mona K.; Sonka, Milan

    2011-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships. PMID:22275207

  14. ImageX: new and improved image explorer for astronomical images and beyond

    Science.gov (United States)

    Hayashi, Soichi; Gopu, Arvind; Kotulla, Ralf; Young, Michael D.

    2016-08-01

    The One Degree Imager - Portal, Pipeline, and Archive (ODI-PPA) has included the Image Explorer interactive image visualization tool since it went operational. Portal users were able to quickly open up several ODI images within any HTML5 capable web browser, adjust the scaling, apply color maps, and perform other basic image visualization steps typically done on a desktop client like DS9. However, the original design of the Image Explorer required lossless PNG tiles to be generated and stored for all raw and reduced ODI images thereby taking up tens of TB of spinning disk space even though a small fraction of those images were being accessed by portal users at any given time. It also caused significant overhead on the portal web application and the Apache webserver used by ODI-PPA. We found it hard to merge in improvements made to a similar deployment in another project's portal. To address these concerns, we re-architected Image Explorer from scratch and came up with ImageX, a set of microservices that are part of the IU Trident project software suite, with rapid interactive visualization capabilities useful for ODI data and beyond. We generate a full resolution JPEG image for each raw and reduced ODI FITS image before producing a JPG tileset, one that can be rendered using the ImageX frontend code at various locations as appropriate within a web portal (for example: on tabular image listings, views allowing quick perusal of a set of thumbnails or other image sifting activities). The new design has decreased spinning disk requirements, uses AngularJS for the client side Model/View code (instead of depending on backend PHP Model/View/Controller code previously used), OpenSeaDragon to render the tile images, and uses nginx and a lightweight NodeJS application to serve tile images thereby significantly decreasing the Time To First Byte latency by a few orders of magnitude. We plan to extend ImageX for non-FITS images including electron microscopy and radiology scan

  15. Imaging system design and image interpolation based on CMOS image sensor

    Science.gov (United States)

    Li, Yu-feng; Liang, Fei; Guo, Rui

    2009-11-01

    An image acquisition system is introduced, which consists of a color CMOS image sensor (OV9620), SRAM (CY62148), CPLD (EPM7128AE) and DSP (TMS320VC5509A). The CPLD implements the logic and timing control to the system. SRAM stores the image data, and DSP controls the image acquisition system through the SCCB (Omni Vision Serial Camera Control Bus). The timing sequence of the CMOS image sensor OV9620 is analyzed. The imaging part and the high speed image data memory unit are designed. The hardware and software design of the image acquisition and processing system is given. CMOS digital cameras use color filter arrays to sample different spectral components, such as red, green, and blue. At the location of each pixel only one color sample is taken, and the other colors must be interpolated from neighboring samples. We use the edge-oriented adaptive interpolation algorithm for the edge pixels and bilinear interpolation algorithm for the non-edge pixels to improve the visual quality of the interpolated images. This method can get high processing speed, decrease the computational complexity, and effectively preserve the image edges.

  16. Image registration via optimization over disjoint image regions

    Science.gov (United States)

    Pitts, Todd; Hathaway, Simon; Karelitz, David B.; Sandusky, John; Laine, Mark Richard

    2018-02-06

    Technologies pertaining to registering a target image with a base image are described. In a general embodiment, the base image is selected from a set of images, and the target image is an image in the set of images that is to be registered to the base image. A set of disjoint regions of the target image is selected, and a transform to be applied to the target image is computed based on the optimization of a metric over the selected set of disjoint regions. The transform is applied to the target image so as to register the target image with the base image.

  17. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method

    Directory of Open Access Journals (Sweden)

    Lázzari Julio O.

    1998-01-01

    Full Text Available An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (k index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (k = 0.66; SE 0.02. While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  18. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method

    Directory of Open Access Journals (Sweden)

    Julio O. Lázzari

    1998-11-01

    Full Text Available An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (k index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (k = 0.66; SE 0.02. While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  19. Image processing with ImageJ

    CERN Document Server

    Pascau, Javier

    2013-01-01

    The book will help readers discover the various facilities of ImageJ through a tutorial-based approach.This book is targeted at scientists, engineers, technicians, and managers, and anyone who wishes to master ImageJ for image viewing, processing, and analysis. If you are a developer, you will be able to code your own routines after you have finished reading this book. No prior knowledge of ImageJ is expected.

  20. Ultrasonic image analysis and image-guided interventions.

    Science.gov (United States)

    Noble, J Alison; Navab, Nassir; Becher, H

    2011-08-06

    The fields of medical image analysis and computer-aided interventions deal with reducing the large volume of digital images (X-ray, computed tomography, magnetic resonance imaging (MRI), positron emission tomography and ultrasound (US)) to more meaningful clinical information using software algorithms. US is a core imaging modality employed in these areas, both in its own right and used in conjunction with the other imaging modalities. It is receiving increased interest owing to the recent introduction of three-dimensional US, significant improvements in US image quality, and better understanding of how to design algorithms which exploit the unique strengths and properties of this real-time imaging modality. This article reviews the current state of art in US image analysis and its application in image-guided interventions. The article concludes by giving a perspective from clinical cardiology which is one of the most advanced areas of clinical application of US image analysis and describing some probable future trends in this important area of ultrasonic imaging research.

  1. Imaging windows for long-term intravital imaging

    Science.gov (United States)

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure. PMID:28243510

  2. Improved image alignment method in application to X-ray images and biological images.

    Science.gov (United States)

    Wang, Ching-Wei; Chen, Hsiang-Chou

    2013-08-01

    Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.

  3. scikit-image: image processing in Python.

    Science.gov (United States)

    van der Walt, Stéfan; Schönberger, Johannes L; Nunez-Iglesias, Juan; Boulogne, François; Warner, Joshua D; Yager, Neil; Gouillart, Emmanuelle; Yu, Tony

    2014-01-01

    scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  4. scikit-image: image processing in Python

    Directory of Open Access Journals (Sweden)

    Stéfan van der Walt

    2014-06-01

    Full Text Available scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  5. Automatic UAV Image Geo-Registration by Matching UAV Images to Georeferenced Image Data

    Directory of Open Access Journals (Sweden)

    Xiangyu Zhuo

    2017-04-01

    Full Text Available Recent years have witnessed the fast development of UAVs (unmanned aerial vehicles. As an alternative to traditional image acquisition methods, UAVs bridge the gap between terrestrial and airborne photogrammetry and enable flexible acquisition of high resolution images. However, the georeferencing accuracy of UAVs is still limited by the low-performance on-board GNSS and INS. This paper investigates automatic geo-registration of an individual UAV image or UAV image blocks by matching the UAV image(s with a previously taken georeferenced image, such as an individual aerial or satellite image with a height map attached or an aerial orthophoto with a DSM (digital surface model attached. As the biggest challenge for matching UAV and aerial images is in the large differences in scale and rotation, we propose a novel feature matching method for nadir or slightly tilted images. The method is comprised of a dense feature detection scheme, a one-to-many matching strategy and a global geometric verification scheme. The proposed method is able to find thousands of valid matches in cases where SIFT and ASIFT fail. Those matches can be used to geo-register the whole UAV image block towards the reference image data. When the reference images offer high georeferencing accuracy, the UAV images can also be geolocalized in a global coordinate system. A series of experiments involving different scenarios was conducted to validate the proposed method. The results demonstrate that our approach achieves not only decimeter-level registration accuracy, but also comparable global accuracy as the reference images.

  6. The present role of nuclear cardiology in clinical practice

    International Nuclear Information System (INIS)

    Clark, A.N.; Beller, G.A.

    2005-01-01

    Many advances have been made in the field of nuclear cardiology in the past decade for enhancing the diagnostic and prognostic value of stress myocardial variability using SPECT technology. Gated SPECT for determining regional and global function have provided incremental diagnostic and prognostic information in the evaluation of patients with suspected or known coronary artery disease. Left ventricular ejection fraction and regional myocardial wall thickening can now be simultaneously evaluated with regional perfusion particularly with the use of the 99m Tc-labeled perfusion agents such as sestamibi and tetrofosmin. Many studies have shown that the extent and severity of stress-induced perfusion defects have incremental prognostic value over exercise electrocardiographic stress test variables alone. Patients with normal perfusions scans have 201 Tl or with one of the 99m Tc-labeled imaging agents, or PET imaging with 18 F-deoxyglucose can accurately distinguish viable from irreversibility injured myocardium providing useful information for identifying which patients with ischemic cardiomyopathy benefit most from coronary revascularization with a subsequent improvement in left ventricular function and enhanced survival. Finally, serial stress perfusion imaging can be employed to monitor the efficacy of medical therapy that improves endothelial function and myocardial blood flow reserve

  7. Torso geometry reconstruction and body surface electrode localization using three-dimensional photography.

    Science.gov (United States)

    Perez-Alday, Erick A; Thomas, Jason A; Kabir, Muammar; Sedaghat, Golriz; Rogovoy, Nichole; van Dam, Eelco; van Dam, Peter; Woodward, William; Fuss, Cristina; Ferencik, Maros; Tereshchenko, Larisa G

    We conducted a prospective clinical study (n=14; 29% female) to assess the accuracy of a three-dimensional (3D) photography-based method of torso geometry reconstruction and body surface electrodes localization. The position of 74 body surface electrocardiographic (ECG) electrodes (diameter 5mm) was defined by two methods: 3D photography, and CT (marker diameter 2mm) or MRI (marker size 10×20mm) imaging. Bland-Altman analysis showed good agreement in X (bias -2.5 [95% limits of agreement (LoA) -19.5 to 14.3] mm), Y (bias -0.1 [95% LoA -14.1 to 13.9] mm), and Z coordinates (bias -0.8 [95% LoA -15.6 to 14.2] mm), as defined by the CT/MRI imaging, and 3D photography. The average Hausdorff distance between the two torso geometry reconstructions was 11.17±3.05mm. Thus, accurate torso geometry reconstruction using 3D photography is feasible. Body surface ECG electrodes coordinates as defined by the CT/MRI imaging, and 3D photography, are in good agreement. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Exercise thallium testing in ventricular preexcitation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-05-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation.

  9. Exercise thallium testing in ventricular preexcitation

    International Nuclear Information System (INIS)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-01-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation

  10. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran's Electronic Health Record (EHR) System.

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-04-01

    Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. to determine the minimum data set of echocardiography reporting system to exchange with Iran's electronic health record (EHR) system. First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients' records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. The highest degree of consensus was found for the following MDSs: patient's name and family name (5), accepting doctor's name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran's electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider.

  11. Markerless registration for image guided surgery. Preoperative image, intraoperative video image, and patient

    International Nuclear Information System (INIS)

    Kihara, Tomohiko; Tanaka, Yuko

    1998-01-01

    Real-time and volumetric acquisition of X-ray CT, MR, and SPECT is the latest trend of the medical imaging devices. A clinical challenge is to use these multi-modality volumetric information complementary on patient in the entire diagnostic and surgical processes. The intraoperative image and patient integration intents to establish a common reference frame by image in diagnostic and surgical processes. This provides a quantitative measure during surgery, for which we have been relied mostly on doctors' skills and experiences. The intraoperative image and patient integration involves various technologies, however, we think one of the most important elements is the development of markerless registration, which should be efficient and applicable to the preoperative multi-modality data sets, intraoperative image, and patient. We developed a registration system which integrates preoperative multi-modality images, intraoperative video image, and patient. It consists of a real-time registration of video camera for intraoperative use, a markerless surface sampling matching of patient and image, our previous works of markerless multi-modality image registration of X-ray CT, MR, and SPECT, and an image synthesis on video image. We think these techniques can be used in many applications which involve video camera like devices such as video camera, microscope, and image Intensifier. (author)

  12. Image processing and recognition for biological images.

    Science.gov (United States)

    Uchida, Seiichi

    2013-05-01

    This paper reviews image processing and pattern recognition techniques, which will be useful to analyze bioimages. Although this paper does not provide their technical details, it will be possible to grasp their main tasks and typical tools to handle the tasks. Image processing is a large research area to improve the visibility of an input image and acquire some valuable information from it. As the main tasks of image processing, this paper introduces gray-level transformation, binarization, image filtering, image segmentation, visual object tracking, optical flow and image registration. Image pattern recognition is the technique to classify an input image into one of the predefined classes and also has a large research area. This paper overviews its two main modules, that is, feature extraction module and classification module. Throughout the paper, it will be emphasized that bioimage is a very difficult target for even state-of-the-art image processing and pattern recognition techniques due to noises, deformations, etc. This paper is expected to be one tutorial guide to bridge biology and image processing researchers for their further collaboration to tackle such a difficult target. © 2013 The Author Development, Growth & Differentiation © 2013 Japanese Society of Developmental Biologists.

  13. IMAGE DESCRIPTIONS FOR SKETCH BASED IMAGE RETRIEVAL

    OpenAIRE

    SAAVEDRA RONDO, JOSE MANUEL; SAAVEDRA RONDO, JOSE MANUEL

    2008-01-01

    Due to the massive use of Internet together with the proliferation of media devices, content based image retrieval has become an active discipline in computer science. A common content based image retrieval approach requires that the user gives a regular image (e.g, a photo) as a query. However, having a regular image as query may be a serious problem. Indeed, people commonly use an image retrieval system because they do not count on the desired image. An easy alternative way t...

  14. Image formation and image analysis in electron microscopy

    International Nuclear Information System (INIS)

    Heel, M. van.

    1981-01-01

    This thesis covers various aspects of image formation and image analysis in electron microscopy. The imaging of relatively strong objects in partially coherent illumination, the coherence properties of thermionic emission sources and the detection of objects in quantum noise limited images are considered. IMAGIC, a fast, flexible and friendly image analysis software package is described. Intelligent averaging of molecular images is discussed. (C.F.)

  15. ImageSURF: An ImageJ Plugin for Batch Pixel-Based Image Segmentation Using Random Forests

    Directory of Open Access Journals (Sweden)

    Aidan O'Mara

    2017-11-01

    Full Text Available Image segmentation is a necessary step in automated quantitative imaging. ImageSURF is a macro-compatible ImageJ2/FIJI plugin for pixel-based image segmentation that considers a range of image derivatives to train pixel classifiers which are then applied to image sets of any size to produce segmentations without bias in a consistent, transparent and reproducible manner. The plugin is available from ImageJ update site http://sites.imagej.net/ImageSURF/ and source code from https://github.com/omaraa/ImageSURF. Funding statement: This research was supported by an Australian Government Research Training Program Scholarship.

  16. Fast processing of foreign fiber images by image blocking

    Directory of Open Access Journals (Sweden)

    Yutao Wu

    2014-08-01

    Full Text Available In the textile industry, it is always the case that cotton products are constitutive of many types of foreign fibers which affect the overall quality of cotton products. As the foundation of the foreign fiber automated inspection, image process exerts a critical impact on the process of foreign fiber identification. This paper presents a new approach for the fast processing of foreign fiber images. This approach includes five main steps, image block, image pre-decision, image background extraction, image enhancement and segmentation, and image connection. At first, the captured color images were transformed into gray-scale images; followed by the inversion of gray-scale of the transformed images ; then the whole image was divided into several blocks. Thereafter, the subsequent step is to judge which image block contains the target foreign fiber image through image pre-decision. Then we segment the image block via OSTU which possibly contains target images after background eradication and image strengthening. Finally, we connect those relevant segmented image blocks to get an intact and clear foreign fiber target image. The experimental result shows that this method of segmentation has the advantage of accuracy and speed over the other segmentation methods. On the other hand, this method also connects the target image that produce fractures therefore getting an intact and clear foreign fiber target image.

  17. A method of image improvement in three-dimensional imaging

    International Nuclear Information System (INIS)

    Suto, Yasuzo; Huang, Tewen; Furuhata, Kentaro; Uchino, Masafumi.

    1988-01-01

    In general, image interpolation is required when the surface configurations of such structures as bones and organs are three-dimensionally constructed from the multi-sliced images obtained by CT. Image interpolation is a processing method whereby an artificial image is inserted between two adjacent slices to make spatial resolution equal to slice resolution in appearance. Such image interpolation makes it possible to increase the image quality of the constructed three-dimensional image. In our newly-developed algorithm, we have converted the presently and subsequently sliced images to distance images, and generated the interpolation images from these two distance images. As a result, compared with the previous method, three-dimensional images with better image quality have been constructed. (author)

  18. Image processing with ImageJ

    NARCIS (Netherlands)

    Abramoff, M.D.; Magalhães, Paulo J.; Ram, Sunanda J.

    2004-01-01

    Wayne Rasband of NIH has created ImageJ, an open source Java-written program that is now at version 1.31 and is used for many imaging applications, including those that that span the gamut from skin analysis to neuroscience. ImageJ is in the public domain and runs on any operating system (OS).

  19. Compositional images from the Diffraction Enhanced Imaging technique

    International Nuclear Information System (INIS)

    Hasnah, M.O.; Zhong, Z.; Parham, C.; Zhang, H.; Chapman, D.

    2007-01-01

    Diffraction Enhanced Imaging (DEI) derives X-ray contrast from absorption, refraction, and extinction. While the refraction angle image of DEI represents the gradient of the projected mass density of the object, the absorption image measures the projected attenuation (μt)-bar of an object. Using a simple integral method it has been shown that a mass density image (ρt)-bar can be obtained from the refraction angle image. It then is a simple matter to develop a combinational image by dividing these two images to create a μ/ρ image. The μ/ρ is a fundamental property of a material and is therefore useful for identifying the composition of an object. In projection X-ray imaging the μ/ρ image identifies the integrated composition of the elements along the beam path. When applied to DEI computed tomography (CT), the image identifies the composition in each voxel. This method presents a new type of spectroscopy based in radiography. We present the method of obtaining the compositional image, the results of experiments in which we verify the method with known standards and an application of the method to breast cancer imaging

  20. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  1. Improving the Image Quality of Synthetic Transmit Aperture Ultrasound Images - Achieving Real-Time In-Vivo Imaging

    DEFF Research Database (Denmark)

    Gammelmark, Kim

    in-vivo experiments, showed, that TMS imaging can increase the SNR by as much as 17 dB compared to the traditional imaging techniques, which improves the in-vivo image quality to a highly competitive level. An in-vivo evaluation of convex array TMS imaging for abdominal imaging applications......-vivo imaging, and that the obtained image quality is highly competitive with the techniques applied in current medical ultrasound scanners. Hereby, the goals of the PhD have been successfully achieved.......Synthetic transmit aperture (STA) imaging has the potential to increase the image quality of medical ultrasound images beyond the levels obtained by conventional imaging techniques (linear, phased, and convex array imaging). Currently, however, in-vivo applications of STA imaging is limited...

  2. Características clínicas, electrocardiográficas y ecocardiográficas de la cardiomiopatía chagásica en la población santandereana Clinical, electrocardiographic and echocardiographic characteristics of Chagas’ cardiomyopathy in Santander’s State (Colombia population

    Directory of Open Access Journals (Sweden)

    Franklin Quiroz

    main clinical presentation of CD in Colombia. This article describes the main clinical, electrocardiographic and echocardiographic characteristics of the CCM in Santander, Colombia. Materials and methods: A cross-sectional study of patients of ages between 18 and 80 years, from the Department of Santander, Colombia, with positive serology for T. cruzi, and symptoms of non-terminal heart failure was performed. Physical examination, 12-lead electrocardiogram and 2D echocardiogram were carried out. Results: The study included 62 women and 57 men, mean age 58.5±10.7 years. Hypertension (49.6%, pacemaker implantation (8.4% and dyslipidemia (7.6% were the most frequent antecedents. Left ventricular hypertrophy was seen in 34.3% of the subjects and it was associated to abnormalities in re-polarization. Right bundle branch block was determined in 11.8% of the subjects. Mitral insufficiency was identified by echocardiogram in 61.5% of the participants. None of these variables were associated with a worse functional class state. Discussion: The electrocardiographic characteristics in patients with CCM in Colombia seem to have a different behaviour according to the regions, and for Santander the most frequent findings were left ventricular hypertrophy, abnormalities in repolarization and right bundle branch block. Early interventions on this group of patients are necessary in order to reduce the social and economic impact associated to the CCM.

  3. Recidiverende tilfaelde af Takotsubosyndrom

    DEFF Research Database (Denmark)

    Theibich, Ali; Klarlund, Kim; Taskiran, Mustafa

    2009-01-01

    We report the first case in Denmark of a woman with three episodes of transient myocardial injury (Takotsubo or stress cardiomyopathy). The condition, which mimicks acute myocardial infarction with chest pain, electrocardiographic changes and slightly elevated coronary enzymes has been explained ...... by exaggerated sympathetic activity in the apical region of the left ventricle during emotional or physical stress causing apical ballooning. Despite this, coronary arteries are usually normal and ballooning is reversible. Udgivelsesdato: 2009-Sep-14......We report the first case in Denmark of a woman with three episodes of transient myocardial injury (Takotsubo or stress cardiomyopathy). The condition, which mimicks acute myocardial infarction with chest pain, electrocardiographic changes and slightly elevated coronary enzymes has been explained...

  4. The pattern of activation of the sympathetic nervous system during tilt-induced syncope.

    Science.gov (United States)

    Zyśko, Dorota; Gajek, Jacek; Sciborski, Ryszard; Smereka, Jacek; Checiński, Igor; Mazurek, Walentyna

    2007-04-01

    A 49-year-old patient with a history of situational syncope and minimal electrocardiographic signs of accessory pathway is described. The evidence for pre-excitation was present only during the sympathetic activation caused by exercise testing and isoprenaline infusion. This phenomenon served as an indicator of significant adrenergic drive to the heart after the tilt-induced syncope. The meaning of the observed electrocardiographic changes in the course of neurocardiogenic reaction and its contribution to the understanding of the sympatho-vagal balance during vasovagal syncope is discussed. The lack of preexcitation signs during syncope and its appearance several seconds after the syncope-related sinus pause indicates sympathetic withdrawal before and shortly after the asystole. The possible pathophysiological mechanisms are discussed.

  5. Alterações eletrocardiográficas e sua relação com os fatores de risco para doença isquêmica do coração em população da área metropolitana de São Paulo Electrocardiographic abnormalities and cardiovascular risk factors for ischemic heart disease in an adult population from São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    ELISABETH CARDOSO

    2002-09-01

    sobrepeso ou obesidade (³25 Kg/m2,relação cintura/quadril alterada correlacionaram-se positivamente com ARV. O sexo masculino, diabetes, hipertensão arterial e o tabagismo foram correlacionados positivamente com SVE. Na presença de ARV no ECG encontramos uma razão de chance de 3,54 para a ocorrência do diagnóstico de hipertensão sistólica e de 1,83 para colesterol total ³ a 200 mg/dl. Na presença de SVE no ECG, a razão de chance para a ocorrência do diagnóstico de hipertensão sistólica observada foi de 5,92. Dos três fatores de risco correlacionados às alterações eletrocardiográficas associadas à isquemia miocárdia, dois são controláveis e ligados a condições nutricionais (hipertensão e colesterol ³ a 200 mg/dl, o que demonstra a importância da sua detecção precoce. Em estudos epidemiológicos e de intervenção nutricional, o eletrocardiograma, método simples e de baixo custo, pode auxiliar na identificação de fatores de risco cardiovascular. Seria importante que estas informações fossem confirmadas por estudos prospectivos que incluíssem a determinação dos valores preditivos do ECG nesta situação.OBJETIVE: Ischemic heart disease is associated with high rates of mortality and it is the most prevalent among cardiovascular diseases. It is a multifactorial disease, and its prevention depends on control of risk factors. Resting electrocardiogram can be used to detect manifestations of ischemic heart disease, since some electrocardiographic abnormalities are indicative of coronary disease in asymptomatic subjects. The aim of the study was to analyze the relationship between electrocardiographic abnormalities and risk factors for ischemic heart disease in an adult population from the metropolitan area of São Paulo. METHODS: A cross-sectional study was carried out in an adult population (age 20 years and over from Cotia, near São Paulo, southeastern of Brazil. The study population comprised 1067 subjects. The subjects were interviewed

  6. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  7. Image registration of naval IR images

    Science.gov (United States)

    Rodland, Arne J.

    1996-06-01

    In a real world application an image from a stabilized sensor on a moving platform will not be 100 percent stabilized. There will always be a small unknown error in the stabilization due to factors such as dynamic deformations in the structure between sensor and reference Inertial Navigation Unit, servo inaccuracies, etc. For a high resolution imaging sensor this stabilization error causes the image to move several pixels in unknown direction between frames. TO be able to detect and track small moving objects from such a sensor, this unknown movement of the sensor image must be estimated. An algorithm that searches for land contours in the image has been evaluated. The algorithm searches for high contrast points distributed over the whole image. As long as moving objects in the scene only cover a small area of the scene, most of the points are located on solid ground. By matching the list of points from frame to frame, the movement of the image due to stabilization errors can be estimated and compensated. The point list is searched for points with diverging movement from the estimated stabilization error. These points are then assumed to be located on moving objects. Points assumed to be located on moving objects are gradually exchanged with new points located in the same area. Most of the processing is performed on the list of points and not on the complete image. The algorithm is therefore very fast and well suited for real time implementation. The algorithm has been tested on images from an experimental IR scanner. Stabilization errors were added artificially to the image such that the output from the algorithm could be compared with the artificially added stabilization errors.

  8. Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture

    Science.gov (United States)

    Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

    2013-01-08

    Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

  9. Regression of electrocardiographic left ventricular hypertrophy or strain is associated with lower incidence of cardiovascular morbidity and mortality in hypertensive patients independent of blood pressure reduction - A LIFE review.

    Science.gov (United States)

    Bang, Casper N; Devereux, Richard B; Okin, Peter M

    2014-01-01

    Cornell product criteria, Sokolow-Lyon voltage criteria and electrocardiographic (ECG) strain (secondary ST-T abnormalities) are markers for left ventricular hypertrophy (LVH) and adverse prognosis in population studies. However, the relationship of regression of ECG LVH and strain during antihypertensive therapy to cardiovascular (CV) risk was unclear before the Losartan Intervention for Endpoint Reduction in Hypertension (LIFE) study. We reviewed findings on ECG LVH regression and strain over time in 9193 hypertensive patients with ECG LVH at baseline enrolled in the LIFE study. The composite endpoint of CV death, nonfatal MI, or stroke occurred in 1096 patients during 4.8±0.9years follow-up. In Cox multivariable models adjusting for randomized treatment, known risk factors including in-treatment blood pressure, and for severity ECG LVH by Cornell product and Sokolow-Lyon voltage, baseline ECG strain was associated with a 33% higher risk of the LIFE composite endpoint (HR. 1.33, 95% CI [1.11-1.59]). Development of new ECG strain between baseline and year-1 was associated with a 2-fold increased risk of the composite endpoint (HR. 2.05, 95% CI [1.51-2.78]), whereas the risk associated with regression or persistence of ECG strain was attenuated and no longer statistically significant (both p>0.05). After controlling for treatment with losartan or atenolol, for baseline Framingham risk score, Cornell product, and Sokolow-Lyon voltage, and for baseline and in-treatment systolic and diastolic blood pressure, 1 standard deviation (SD) lower in-treatment Cornell product was associated with a 14.5% decrease in the composite endpoint (HR. 0.86, 95% CI [0.82-0.90]). In a parallel analysis, 1 SD lower in-treatment Sokolow-Lyon voltage was associated with a 16.6% decrease in the composite endpoint (HR. 0.83, 95% CI [0.78-0.88]). The LIFE study shows that evaluation of both baseline and in-study ECG LVH defined by Cornell product criteria, Sokolow-Lyon voltage criteria or

  10. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  11. Image quality of digital mammography images produced using wet and dry laser imaging systems

    International Nuclear Information System (INIS)

    Al Khalifah, K.; Brindhaban, A.; AlArfaj, R.; Jassim, O.

    2006-01-01

    Introduction: A study was carried out to compare the quality of digital mammographic images printed or processed by a wet laser imaging system and a dedicated mammographic dry laser imaging system. Material and methods: Digital images of a tissue equivalent breast phantom were obtained using a GE Senographe 2000D digital mammography system and different target/filter combinations of the X-ray tube. These images were printed on films using the Fuji FL-IM D wet laser imaging system and the Kodak DryView 8600 dry laser imaging system. The quality of images was assessed in terms of detectability of microcalcifications and simulated tumour masses by five radiologists. In addition, the contrast index and speed index of the two systems were measured using the step wedge in the phantom. The unpaired, unequal variance t-test was used to test any statistically significant differences. Results: There were no significant (p < 0.05) differences between the images printed using the two systems in terms of microcalcification and tumour mass detectability. The wet system resulted in slightly higher contrast index while the dry system showed significantly higher speed index. Conclusion: Both wet and dry laser imaging systems can produce mammography images of good quality on which 0.2 mm microcalcifications and 2 mm tumour masses can be detected. Dry systems are preferable due to the absence of wet chemical processing and solid or liquid chemical waste. The wet laser imaging systems, however, still represent a useful alternative to dry laser imaging systems for mammography studies

  12. Television Images and Adolescent Girls' Body Image Disturbance.

    Science.gov (United States)

    Botta, Renee A.

    1999-01-01

    Contributes to scholarship on the effects of media images on adolescents, using social-comparison theory and critical-viewing theory. Finds that media do have an impact on body-image disturbance. Suggests that body-image processing is the key to understanding how television images affect adolescent girls' body-image attitudes and behaviors. (SR)

  13. To Image...or Not to Image?

    Science.gov (United States)

    Bruley, Karina

    1996-01-01

    Provides a checklist of considerations for installing document image processing with an electronic document management system. Other topics include scanning; indexing; the image file life cycle; benefits of imaging; document-driven workflow; and planning for workplace changes like postsorting, creating a scanning room, redeveloping job tasks and…

  14. Edge-based correlation image registration for multispectral imaging

    Science.gov (United States)

    Nandy, Prabal [Albuquerque, NM

    2009-11-17

    Registration information for images of a common target obtained from a plurality of different spectral bands can be obtained by combining edge detection and phase correlation. The images are edge-filtered, and pairs of the edge-filtered images are then phase correlated to produce phase correlation images. The registration information can be determined based on these phase correlation images.

  15. Correlation of Fragmented QRS with Right Ventricular Indexes and Fibrosis in Patients with Repaired Tetralogy of Fallot, by Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Zahra Alizadeh Sani

    2017-09-01

    Full Text Available Background: Repair of tetralogy of fallot (TOF is associated with diffuse myocardial fibrosis. Cardiac magnetic resonance imaging (CMR can visualize the areas with myocardial fibrosis. Presence of fragmented QRS (fQRS implies the presence of the underlying myocardial scar. Despite the strong association between fQRS and myocardial pathologies, the impact of fQRS with myocardial fibrosis in post-TOF correction is unknown. Objectives: Here, we evaluated the possible predictive role of fQRS in repaired TOF cases and its relationship with cardiac function. Patients and Methods: Thirty two patients with previous history of repaired TOF were enrolled. The extent of fQRS was evaluated according to the number of leads with fQRS. After electrocardiographic evaluation, the participants underwent CMR. Results: Results showed a significant relationship between the right ventricular (RV systolic diameter and fQRS (P = 0.014. Also, an inverse linear relationship was found between the number of fQRS edges and RVEF (r = 0.77, P = 0.0001. The mean QRS duration in those with positive and negative fQRS was 132 mm and 115.8 mm (P = 0.0001. Furthermore, a linear correlation was observed between the number of edges and the percentage of scar tissue (r = 0.88, P = 0.001. However, no relevance between gender and fQRS was detected (P = 0.26, and the relationship between RV diastolic diameter and fQRS was not significant (P = 0.1. Thus, fQRS could be used as a marker of RV systolic dysfunction in patients with tetralogy of fallot. Conclusions: We suggested the fQRS as a surrogate indicator of RV dysfunction in repaired TOF patients and showed that diagnostic and prognostic information of the patients were available by fQRS.

  16. ImageSURF MOAB2 Image Example

    OpenAIRE

    O'Mara, Aidan R; Collins, Jessica M; King, Anna E; Vickers, James C; Kirkcaldie, Matthew T K

    2017-01-01

    A set of 2000x2000 confocal fluorescence images of MOAB2-labelled cortex from APPswe/PS1dE9 mouse models of Alzheimer's disease, sparsely annotated pixel labels and reference segmentation examples. Pixels are annotated as signal (red 0xFFFF0000) and background (blue 0xFF0000FF). Images were captured as stitched 12-bit greyscale single-plane images and cropped to size. Image acquisition was performed at 561nm excitation and 615nm emission wavelengths using a Perkin Elmer Ultraview VOX ima...

  17. Vocal Noise Cancellation From Respiratory Sounds

    National Research Council Canada - National Science Library

    Moussavi, Zahra

    2001-01-01

    Although background noise cancellation for speech or electrocardiographic recording is well established, however when the background noise contains vocal noises and the main signal is a breath sound...

  18. Transformation invariant image indexing and retrieval for image databases

    NARCIS (Netherlands)

    Gevers, Th.; Smeulders, A.W.M.

    1994-01-01

    This paper presents a novel design of an image database system which supports storage, indexing and retrieval of images by content. The image retrieval methodology is based on the observation that images can be discriminated by the presence of image objects and their spatial relations. Images in the

  19. Image processing of integrated video image obtained with a charged-particle imaging video monitor system

    International Nuclear Information System (INIS)

    Iida, Takao; Nakajima, Takehiro

    1988-01-01

    A new type of charged-particle imaging video monitor system was constructed for video imaging of the distributions of alpha-emitting and low-energy beta-emitting nuclides. The system can display not only the scintillation image due to radiation on the video monitor but also the integrated video image becoming gradually clearer on another video monitor. The distortion of the image is about 5% and the spatial resolution is about 2 line pairs (lp)mm -1 . The integrated image is transferred to a personal computer and image processing is performed qualitatively and quantitatively. (author)

  20. Hyperspectral small animal fluorescence imaging: spectral selection imaging

    Science.gov (United States)

    Leavesley, Silas; Jiang, Yanan; Patsekin, Valery; Hall, Heidi; Vizard, Douglas; Robinson, J. Paul

    2008-02-01

    Molecular imaging is a rapidly growing area of research, fueled by needs in pharmaceutical drug-development for methods for high-throughput screening, pre-clinical and clinical screening for visualizing tumor growth and drug targeting, and a growing number of applications in the molecular biology fields. Small animal fluorescence imaging employs fluorescent probes to target molecular events in vivo, with a large number of molecular targeting probes readily available. The ease at which new targeting compounds can be developed, the short acquisition times, and the low cost (compared to microCT, MRI, or PET) makes fluorescence imaging attractive. However, small animal fluorescence imaging suffers from high optical scattering, absorption, and autofluorescence. Much of these problems can be overcome through multispectral imaging techniques, which collect images at different fluorescence emission wavelengths, followed by analysis, classification, and spectral deconvolution methods to isolate signals from fluorescence emission. We present an alternative to the current method, using hyperspectral excitation scanning (spectral selection imaging), a technique that allows excitation at any wavelength in the visible and near-infrared wavelength range. In many cases, excitation imaging may be more effective at identifying specific fluorescence signals because of the higher complexity of the fluorophore excitation spectrum. Because the excitation is filtered and not the emission, the resolution limit and image shift imposed by acousto-optic tunable filters have no effect on imager performance. We will discuss design of the imager, optimizing the imager for use in small animal fluorescence imaging, and application of spectral analysis and classification methods for identifying specific fluorescence signals.

  1. Preparing diagnostic 3D images for image registration with planning CT images

    International Nuclear Information System (INIS)

    Tracton, Gregg S.; Miller, Elizabeth P.; Rosenman, Julian; Chang, Sha X.; Sailer, Scott; Boxwala, Azaz; Chaney, Edward L.

    1997-01-01

    Purpose: Pre-radiotherapy (pre-RT) tomographic images acquired for diagnostic purposes often contain important tumor and/or normal tissue information which is poorly defined or absent in planning CT images. Our two years of clinical experience has shown that computer-assisted 3D registration of pre-RT images with planning CT images often plays an indispensable role in accurate treatment volume definition. Often the only available format of the diagnostic images is film from which the original 3D digital data must be reconstructed. In addition, any digital data, whether reconstructed or not, must be put into a form suitable for incorporation into the treatment planning system. The purpose of this investigation was to identify all problems that must be overcome before this data is suitable for clinical use. Materials and Methods: In the past two years we have 3D-reconstructed 300 diagnostic images from film and digital sources. As a problem was discovered we built a software tool to correct it. In time we collected a large set of such tools and found that they must be applied in a specific order to achieve the correct reconstruction. Finally, a toolkit (ediScan) was built that made all these tools available in the proper manner via a pleasant yet efficient mouse-based user interface. Results: Problems we discovered included different magnifications, shifted display centers, non-parallel image planes, image planes not perpendicular to the long axis of the table-top (shearing), irregularly spaced scans, non contiguous scan volumes, multiple slices per film, different orientations for slice axes (e.g. left-right reversal), slices printed at window settings corresponding to tissues of interest for diagnostic purposes, and printing artifacts. We have learned that the specific steps to correct these problems, in order of application, are: Also, we found that fast feedback and large image capacity (at least 2000 x 2000 12-bit pixels) are essential for practical application

  2. Maxillofacial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Larheim, T.A. [Oslo Univ. (Norway). Dept. of Maxillofacial Radiology; Westesson, P.L. [Univ. of Rochester School of Medicine and Dentistry, NY (United States). Div. of Diagnostic and Interventional Radiology

    2006-07-01

    Maxillofacial imaging has evolved dramatically over the past two decades with development of new cross-sectional imaging techniques. Traditional maxillofacial imaging was based on plain films and dental imaging. However, today's advanced imaging techniques with CT and MRI have only been partially implemented for maxillofacial questions. This book bridges the gap between traditional maxillofacial imaging and advanced medical imaging. We have applied CT and MRI to a variety of maxillofacial cases and these are illustrated with high-quality images and multiple planes. A comprehensive chapter on imaging anatomy is also included. This book is useful for oral and maxillofacial radiologists, oral and maxillofacial surgeons, dentists, radiologists, plastic surgeons, head and neck surgeons, and others that work with severe maxillofacial disorders. (orig.)

  3. Separation method of heavy-ion particle image from gamma-ray mixed images using an imaging plate

    CERN Document Server

    Yamadera, A; Ohuchi, H; Nakamura, T; Fukumura, A

    1999-01-01

    We have developed a separation method of alpha-ray and gamma-ray images using the imaging plate (IP). The IP from which the first image was read out by an image reader was annealed at 50 deg. C for 2 h in a drying oven and the second image was read out by the image reader. It was found out that an annealing ratio, k, which is defined as a ratio of the photo-stimulated luminescence (PSL) density at the first measurement to that at the second measurement, was different for alpha rays and gamma rays. By subtracting the second image multiplied by a factor of k from the first image, the alpha-ray image was separated from the alpha and gamma-ray mixed images. This method was applied to identify the images of helium, carbon and neon particles of high energies using the heavy-ion medical accelerator, HIMAC. (author)

  4. 78 FR 29388 - Government-Owned Inventions, Available for Licensing

    Science.gov (United States)

    2013-05-20

    ... Display and Decision Support Interface; NASA Case No.: ARC-16337-1: Method and Device for Biometric Subject Verification and Identification Based Upon Electrocardiographic Signals; NASA Case No.: ARC 16812...

  5. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    Science.gov (United States)

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  6. Multispectral image enhancement processing for microsat-borne imager

    Science.gov (United States)

    Sun, Jianying; Tan, Zheng; Lv, Qunbo; Pei, Linlin

    2017-10-01

    With the rapid development of remote sensing imaging technology, the micro satellite, one kind of tiny spacecraft, appears during the past few years. A good many studies contribute to dwarfing satellites for imaging purpose. Generally speaking, micro satellites weigh less than 100 kilograms, even less than 50 kilograms, which are slightly larger or smaller than the common miniature refrigerators. However, the optical system design is hard to be perfect due to the satellite room and weight limitation. In most cases, the unprocessed data captured by the imager on the microsatellite cannot meet the application need. Spatial resolution is the key problem. As for remote sensing applications, the higher spatial resolution of images we gain, the wider fields we can apply them. Consequently, how to utilize super resolution (SR) and image fusion to enhance the quality of imagery deserves studying. Our team, the Key Laboratory of Computational Optical Imaging Technology, Academy Opto-Electronics, is devoted to designing high-performance microsat-borne imagers and high-efficiency image processing algorithms. This paper addresses a multispectral image enhancement framework for space-borne imagery, jointing the pan-sharpening and super resolution techniques to deal with the spatial resolution shortcoming of microsatellites. We test the remote sensing images acquired by CX6-02 satellite and give the SR performance. The experiments illustrate the proposed approach provides high-quality images.

  7. Enhancement of image contrast in linacgram through image processing

    International Nuclear Information System (INIS)

    Suh, Hyun Suk; Shin, Hyun Kyo; Lee, Re Na

    2000-01-01

    Conventional radiation therapy portal images gives low contrast images. The purpose of this study was to enhance image contrast of a linacgram by developing a low--cost image processing method. Chest linacgram was obtained by irradiating humanoid phantom and scanned using Diagnostic-Pro scanner for image processing. Several types of scan method were used in scanning. These include optical density scan, histogram equalized scan, linear histogram based scan, linear histogram independent scan, linear optical density scan, logarithmic scan, and power square root scan. The histogram distribution of the scanned images were plotted and the ranges of the gray scale were compared among various scan types. The scanned images were then transformed to the gray window by pallette fitting method and the contrast of the reprocessed portal images were evaluated for image improvement. Portal images of patients were also taken at various anatomic sites and the images were processed by Gray Scale Expansion (GSE) method. The patient images were analyzed to examine the feasibility of using the GSE technique in clinic. The histogram distribution showed that minimum and maximum gray scale ranges of 3192 and 21940 were obtained when the image was scanned using logarithmic method and square root method, respectively. Out of 256 gray scale, only 7 to 30% of the steps were used. After expanding the gray scale to full range, contrast of the portal images were improved. Experiment performed with patient image showed that improved identification of organs were achieved by GSE in portal images of knee joint, head and neck, lung, and pelvis. Phantom study demonstrated that the GSE technique improved image contrast of a linacgram. This indicates that the decrease in image quality resulting from the dual exposure, could be improved by expanding the gray scale. As a result, the improved technique will make it possible to compare the digitally reconstructed radiographs (DRR) and simulation image for

  8. Mirror-Image Equivalence and Interhemispheric Mirror-Image Reversal.

    Science.gov (United States)

    Corballis, Michael C

    2018-01-01

    Mirror-image confusions are common, especially in children and in some cases of neurological impairment. They can be a special impediment in activities such as reading and writing directional scripts, where mirror-image patterns (such as b and d ) must be distinguished. Treating mirror images as equivalent, though, can also be adaptive in the natural world, which carries no systematic left-right bias and where the same object or event can appear in opposite viewpoints. Mirror-image equivalence and confusion are natural consequences of a bilaterally symmetrical brain. In the course of learning, mirror-image equivalence may be established through a process of symmetrization, achieved through homotopic interhemispheric exchange in the formation of memory circuits. Such circuits would not distinguish between mirror images. Learning to discriminate mirror-image discriminations may depend either on existing brain asymmetries, or on extensive learning overriding the symmetrization process. The balance between mirror-image equivalence and mirror-image discrimination may nevertheless be precarious, with spontaneous confusions or reversals, such as mirror writing, sometimes appearing naturally or as a manifestation of conditions like dyslexia.

  9. Mirror-Image Equivalence and Interhemispheric Mirror-Image Reversal

    Directory of Open Access Journals (Sweden)

    Michael C. Corballis

    2018-04-01

    Full Text Available Mirror-image confusions are common, especially in children and in some cases of neurological impairment. They can be a special impediment in activities such as reading and writing directional scripts, where mirror-image patterns (such as b and d must be distinguished. Treating mirror images as equivalent, though, can also be adaptive in the natural world, which carries no systematic left-right bias and where the same object or event can appear in opposite viewpoints. Mirror-image equivalence and confusion are natural consequences of a bilaterally symmetrical brain. In the course of learning, mirror-image equivalence may be established through a process of symmetrization, achieved through homotopic interhemispheric exchange in the formation of memory circuits. Such circuits would not distinguish between mirror images. Learning to discriminate mirror-image discriminations may depend either on existing brain asymmetries, or on extensive learning overriding the symmetrization process. The balance between mirror-image equivalence and mirror-image discrimination may nevertheless be precarious, with spontaneous confusions or reversals, such as mirror writing, sometimes appearing naturally or as a manifestation of conditions like dyslexia.

  10. Continuous imaging space in three-dimensional integral imaging

    International Nuclear Information System (INIS)

    Zhang Lei; Yang Yong; Wang Jin-Gang; Zhao Xing; Fang Zhi-Liang; Yuan Xiao-Cong

    2013-01-01

    We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into real and virtual space. Experimental results show that the gap is reduced to 45% of that in a conventional integral imaging system with the same parameters. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  11. Image reconstruction of dynamic infrared single-pixel imaging system

    Science.gov (United States)

    Tong, Qi; Jiang, Yilin; Wang, Haiyan; Guo, Limin

    2018-03-01

    Single-pixel imaging technique has recently received much attention. Most of the current single-pixel imaging is aimed at relatively static targets or the imaging system is fixed, which is limited by the number of measurements received through the single detector. In this paper, we proposed a novel dynamic compressive imaging method to solve the imaging problem, where exists imaging system motion behavior, for the infrared (IR) rosette scanning system. The relationship between adjacent target images and scene is analyzed under different system movement scenarios. These relationships are used to build dynamic compressive imaging models. Simulation results demonstrate that the proposed method can improve the reconstruction quality of IR image and enhance the contrast between the target and the background in the presence of system movement.

  12. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance.

    Directory of Open Access Journals (Sweden)

    Christopher A Mela

    Full Text Available We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b the first wearable system offering both large FOV and microscopic imaging simultaneously,

  13. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  14. Imaging sciences workshop

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J.V.

    1994-11-15

    This workshop on the Imaging Sciences sponsored by Lawrence Livermore National Laboratory contains short abstracts/articles submitted by speakers. The topic areas covered include the following: Astronomical Imaging; biomedical imaging; vision/image display; imaging hardware; imaging software; Acoustic/oceanic imaging; microwave/acoustic imaging; computed tomography; physical imaging; imaging algorithms. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  15. PC image processing

    International Nuclear Information System (INIS)

    Hwa, Mok Jin Il; Am, Ha Jeng Ung

    1995-04-01

    This book starts summary of digital image processing and personal computer, and classification of personal computer image processing system, digital image processing, development of personal computer and image processing, image processing system, basic method of image processing such as color image processing and video processing, software and interface, computer graphics, video image and video processing application cases on image processing like satellite image processing, color transformation of image processing in high speed and portrait work system.

  16. Lossy image compression for digital medical imaging systems

    Science.gov (United States)

    Wilhelm, Paul S.; Haynor, David R.; Kim, Yongmin; Nelson, Alan C.; Riskin, Eve A.

    1990-07-01

    Image compression at rates of 10:1 or greater could make PACS much more responsive and economically attractive. This paper describes a protocol for subjective and objective evaluation of the fidelity of compressed/decompressed images to the originals and presents the results ofits application to four representative and promising compression methods. The methods examined are predictive pruned tree-structured vector quantization, fractal compression, the discrete cosine transform with equal weighting of block bit allocation, and the discrete cosine transform with human visual system weighting of block bit allocation. Vector quantization is theoretically capable of producing the best compressed images, but has proven to be difficult to effectively implement. It has the advantage that it can reconstruct images quickly through a simple lookup table. Disadvantages are that codebook training is required, the method is computationally intensive, and achieving the optimum performance would require prohibitively long vector dimensions. Fractal compression is a relatively new compression technique, but has produced satisfactory results while being computationally simple. It is fast at both image compression and image reconstruction. Discrete cosine iransform techniques reproduce images well, but have traditionally been hampered by the need for intensive computing to compress and decompress images. A protocol was developed for side-by-side observer comparison of reconstructed images with originals. Three 1024 X 1024 CR (Computed Radiography) images and two 512 X 512 X-ray CT images were viewed at six bit rates (0.2, 0.4, 0.6, 0.9, 1.2, and 1.5 bpp for CR, and 1.0, 1.3, 1.6, 1.9, 2.2, 2.5 bpp for X-ray CT) by nine radiologists at the University of Washington Medical Center. The CR images were viewed on a Pixar II Megascan (2560 X 2048) monitor and the CT images on a Sony (1280 X 1024) monitor. The radiologists' subjective evaluations of image fidelity were compared to

  17. Image Analysis for X-ray Imaging of Food

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur

    for quality and safety evaluation of food products. In this effort the fields of statistics, image analysis and statistical learning are combined, to provide analytical tools for determining the aforementioned food traits. The work demonstrated includes a quantitative analysis of heat induced changes......X-ray imaging systems are increasingly used for quality and safety evaluation both within food science and production. They offer non-invasive and nondestructive penetration capabilities to image the inside of food. This thesis presents applications of a novel grating-based X-ray imaging technique...... and defect detection in food. Compared to the complex three dimensional analysis of microstructure, here two dimensional images are considered, making the method applicable for an industrial setting. The advantages obtained by grating-based imaging are compared to conventional X-ray imaging, for both foreign...

  18. Image Processing and Features Extraction of Fingerprint Images ...

    African Journals Online (AJOL)

    To demonstrate the importance of the image processing of fingerprint images prior to image enrolment or comparison, the set of fingerprint images in databases (a) and (b) of the FVC (Fingerprint Verification Competition) 2000 database were analyzed using a features extraction algorithm. This paper presents the results of ...

  19. Image quality at synthetic brain magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Mi; Cho, Seung Hyun; Kim, Won Hwa; Kim, Hye Jung [Kyungpook National University Hospital, Department of Radiology, Daegu (Korea, Republic of); Choi, Young Hun; Cheon, Jung-Eun; Kim, In-One [Seoul National University College of Medicine, Department of Radiology and Institute of Radiation Medicine, Seoul (Korea, Republic of); Cho, Hyun-Hae [Ewha Womans University Mokdong Hospital, Department of Radiology, Seoul (Korea, Republic of); You, Sun-Kyoung [Chungnam National University Hospital, Department of Radiology, Daejeon (Korea, Republic of); Park, Sook-Hyun [Kyungpook National University Hospital, Department of Pediatrics, Daegu (Korea, Republic of); Hwang, Moon Jung [GE Healthcare, MR Applications and Workflow, Seoul (Korea, Republic of)

    2017-11-15

    The clinical application of the multi-echo, multi-delay technique of synthetic magnetic resonance imaging (MRI) generates multiple sequences in a single acquisition but has mainly been used in adults. To evaluate the image quality of synthetic brain MR in children compared with that of conventional images. Twenty-nine children (median age: 6 years, range: 0-16 years) underwent synthetic and conventional imaging. Synthetic (T2-weighted, T1-weighted and fluid-attenuated inversion recovery [FLAIR]) images with settings matching those of the conventional images were generated. The overall image quality, gray/white matter differentiation, lesion conspicuity and image degradations were rated on a 5-point scale. The relative contrasts were assessed quantitatively and acquisition times for the two imaging techniques were compared. Synthetic images were inferior due to more pronounced image degradations; however, there were no significant differences for T1- and T2-weighted images in children <2 years old. The quality of T1- and T2-weighted images were within the diagnostically acceptable range. FLAIR images showed greatly reduced quality. Gray/white matter differentiation was comparable or better in synthetic T1- and T2-weighted images, but poorer in FLAIR images. There was no effect on lesion conspicuity. Synthetic images had equal or greater relative contrast. Acquisition time was approximately two-thirds of that for conventional sequences. Synthetic T1- and T2-weighted images were diagnostically acceptable, but synthetic FLAIR images were not. Lesion conspicuity and gray/white matter differentiation were comparable to conventional MRI. (orig.)

  20. Luminescence imaging using radionuclides: a potential application in molecular imaging

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Il An, Gwang; Park, Se-Il; Oh, Jungmin; Kim, Hong Joo; Su Ha, Yeong; Wang, Eun Kyung; Min Kim, Kyeong; Kim, Jung Young; Lee, Jaetae; Welch, Michael J.; Yoo, Jeongsoo

    2011-01-01

    Introduction: Nuclear and optical imaging are complementary in many aspects and there would be many advantages when optical imaging probes are prepared using radionuclides rather than classic fluorophores, and when nuclear and optical dual images are obtained using single imaging probe. Methods: The luminescence intensities of various radionuclides having different decay modes have been assayed using luminescence imaging and in vitro luminometer. Radioiodinated Herceptin was injected into a tumor-bearing mouse, and luminescence and microPET images were obtained. The plant dipped in [ 32 P]phosphate solution was scanned in luminescence mode. Radio-TLC plate was also imaged in the same imaging mode. Results: Radionuclides emitting high energy β + /β - particles showed higher luminescence signals. NIH3T6.7 tumors were detected in both optical and nuclear imaging. The uptake of [ 32 P]phosphate in plant was easily followed by luminescence imaging. Radio-TLC plate was visualized and radiochemical purity was quantified using luminescence imaging. Conclusion: Many radionuclides with high energetic β + or β - particles during decay were found to be imaged in luminescence mode due mainly to Cerenkov radiation. 'Cerenkov imaging' provides a new optical imaging platform and an invaluable bridge between optical and nuclear imaging. New optical imaging probes could be easily prepared using well-established radioiodination methods. Cerenkov imaging will have more applications in the research field of plant science and autoradiography.

  1. Color image guided depth image super resolution using fusion filter

    Science.gov (United States)

    He, Jin; Liang, Bin; He, Ying; Yang, Jun

    2018-04-01

    Depth cameras are currently playing an important role in many areas. However, most of them can only obtain lowresolution (LR) depth images. Color cameras can easily provide high-resolution (HR) color images. Using color image as a guide image is an efficient way to get a HR depth image. In this paper, we propose a depth image super resolution (SR) algorithm, which uses a HR color image as a guide image and a LR depth image as input. We use the fusion filter of guided filter and edge based joint bilateral filter to get HR depth image. Our experimental results on Middlebury 2005 datasets show that our method can provide better quality in HR depth images both numerically and visually.

  2. Epidural fat image in lumbar magnetic resonance image

    International Nuclear Information System (INIS)

    Nishijima, Yuichiro; Yamasaki, Yasuo; Higashida, Norihiko; Okada, Masato

    1993-01-01

    To examine epidural fat images, lumbar magnetic resonance (MR) images were retrospectively reviewed in a total of 103 patients with surgically proven lumbar disc herniation (DH, n=57) and lumbar canal stenosis (LCS, n=46). Epidural fat images consisted of middorsal epidural fat (MDF), paramedian ventral fat (PVF) and intervertebral foraminal fat (IFF) ones. In the group of DH, the thickness of MDF image did not correlate with that of subcutaneous fat, suggesting that epidural fat was not affected by body fat. From the pathophysiological point of view, decrease and disappearance of MDF images correlated with compression of the epidural canal. Decrease and disappearance of PVF images lead to suspicious compression of the traversing root. In addition, asymmetrical PVF images were useful for the bilateral diagnosis of herniation. Abnormal findings of IFF images were suggestive of compression of the exiting nerve root at the intervertebral foramen. This was also seen frequently at the non-responsible level in patients over the age of 50. Degenerative and sequentrated spondylolistheses in the group of LCS were more frequently associated with a higher incidence of abnormal findings of IFF images, suggesting the presence of existing nerve root compression. (N.K.)

  3. Two markers in predicting the cardiovascular events in patients with polycystic ovary syndrome: increased P-wave and QT dispersion.

    Science.gov (United States)

    Akdag, S; Cim, N; Yildizhan, R; Akyol, A; Ozturk, F; Babat, N

    2015-09-01

    Polycystic ovary syndrome (PCOS) is a prevalent disease with many potential long-term cardiovascular risks. P-wave dispersion (Pdis) and QT dispersion (QTdis) have been shown to be noninvasive electrocardiographic predictors for development of cardiac arrhythmias. In this study we aimed to search Pdis and QTdis parameters in patients with PCOS. The study included 82 patients with PCOS and 74 age- and sex-matched healthy controls. Baseline 12-lead electrocardiographic and transthoracic echocardiographic measurements were evaluated. P-wave maximum duration (Pmax), P-wave minimum duration (Pmin), Pdis, QT interval, heart rate-corrected QT dispersion and QTdis were calculated by two cardiologists. Patients wirh PCOS had significantly higher QT dispersion (49.5 ± 14.1 vs. 37.9 ± 12.6 ms, p PCOS patients.

  4. RELEVANCIA DEL DIAGNÓSTICO DIFERENCIAL ENTRE EL SÍNDROME AÓRTICO AGUDO Y EL SÍNDROME CORONARIO AGUDO EN PACIENTES CON DOLOR TORÁCICO Y CRISIS HIPERTENSIVA: REVISIÓN A PROPÓSITO DE 2 CASOS / Relevance of the differential diagnosis between acute aortic syndrome and acute coronary syndrome in patients with thoracic pain and hypertensive crisis: review on 2 case reports

    Directory of Open Access Journals (Sweden)

    Borja Simó Sánchez

    2011-11-01

    Full Text Available Acute aortic syndrome is a pathological process with low incidence compared with acute coronary syndrome, although with a worse prognosis in the short term, which is why its early diagnosis and urgent treatment are essential to the favorable evolution of thepatient. Electrocardiographic changes suggestive of myocardial ischemia, with acute evolution, are rare in acute aortic syndrome. Even in the presence of a suggestive thoracic pain and high levels of blood pressure, an adequate differential diagnosis is of utmost importance, since the administration of anticoagulation and antiplatelet therapy in high doses can have a dramatic impact on patient outcome. Two cases are presented in which electrocardiographic changes determined the action to take in patients with acute aortic syndrome.

  5. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran’s Electronic Health Record (EHR) System

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-01-01

    Background: Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. Aim: to determine the minimum data set of echocardiography reporting system to exchange with Iran’s electronic health record (EHR) system. Methods: First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients’ records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. Results: The highest degree of consensus was found for the following MDSs: patient’s name and family name (5), accepting doctor’s name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. Conclusions: To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran’s electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider. PMID:27147803

  6. Improving image quality in portal venography with spectral CT imaging

    International Nuclear Information System (INIS)

    Zhao, Li-qin; He, Wen; Li, Jian-ying; Chen, Jiang-hong; Wang, Ke-yang; Tan, Li

    2012-01-01

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  7. Improving image quality in portal venography with spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Li-qin, E-mail: zhaolqzr@sohu.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); He, Wen, E-mail: hewen1724@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Li, Jian-ying, E-mail: jianying.li@med.ge.com [CT Advanced Application and Research, GE Healthcare, 100176 China (China); Chen, Jiang-hong, E-mail: chenjianghong1973@hotmail.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Wang, Ke-yang, E-mail: ke7ke@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Tan, Li, E-mail: Litan@ge.com [CT product, GE Healthcare, 100176 China (China)

    2012-08-15

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  8. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  9. Fluorescence Image Segmentation by using Digitally Reconstructed Fluorescence Images

    OpenAIRE

    Blumer, Clemens; Vivien, Cyprien; Oertner, Thomas G; Vetter, Thomas

    2011-01-01

    In biological experiments fluorescence imaging is used to image living and stimulated neurons. But the analysis of fluorescence images is a difficult task. It is not possible to conclude the shape of an object from fluorescence images alone. Therefore, it is not feasible to get good manual segmented nor ground truth data from fluorescence images. Supervised learning approaches are not possible without training data. To overcome this issues we propose to synthesize fluorescence images and call...

  10. Medical Image Tamper Detection Based on Passive Image Authentication.

    Science.gov (United States)

    Ulutas, Guzin; Ustubioglu, Arda; Ustubioglu, Beste; V Nabiyev, Vasif; Ulutas, Mustafa

    2017-12-01

    Telemedicine has gained popularity in recent years. Medical images can be transferred over the Internet to enable the telediagnosis between medical staffs and to make the patient's history accessible to medical staff from anywhere. Therefore, integrity protection of the medical image is a serious concern due to the broadcast nature of the Internet. Some watermarking techniques are proposed to control the integrity of medical images. However, they require embedding of extra information (watermark) into image before transmission. It decreases visual quality of the medical image and can cause false diagnosis. The proposed method uses passive image authentication mechanism to detect the tampered regions on medical images. Structural texture information is obtained from the medical image by using local binary pattern rotation invariant (LBPROT) to make the keypoint extraction techniques more successful. Keypoints on the texture image are obtained with scale invariant feature transform (SIFT). Tampered regions are detected by the method by matching the keypoints. The method improves the keypoint-based passive image authentication mechanism (they do not detect tampering when the smooth region is used for covering an object) by using LBPROT before keypoint extraction because smooth regions also have texture information. Experimental results show that the method detects tampered regions on the medical images even if the forged image has undergone some attacks (Gaussian blurring/additive white Gaussian noise) or the forged regions are scaled/rotated before pasting.

  11. Image Gallery

    Science.gov (United States)

    ... R S T U V W X Y Z Image Gallery Share: The Image Gallery contains high-quality digital photographs available from ... Select a category below to view additional thumbnail images. Images are available for direct download in 2 ...

  12. Selections from 2017: Image Processing with AstroImageJ

    Science.gov (United States)

    Kohler, Susanna

    2017-12-01

    Editors note:In these last two weeks of 2017, well be looking at a few selections that we havent yet discussed on AAS Nova from among the most-downloaded paperspublished in AAS journals this year. The usual posting schedule will resume in January.AstroImageJ: Image Processing and Photometric Extraction for Ultra-Precise Astronomical Light CurvesPublished January2017The AIJ image display. A wide range of astronomy specific image display options and image analysis tools are available from the menus, quick access icons, and interactive histogram. [Collins et al. 2017]Main takeaway:AstroImageJ is a new integrated software package presented in a publication led byKaren Collins(Vanderbilt University,Fisk University, andUniversity of Louisville). Itenables new users even at the level of undergraduate student, high school student, or amateur astronomer to quickly start processing, modeling, and plotting astronomical image data.Why its interesting:Science doesnt just happen the momenta telescope captures a picture of a distantobject. Instead, astronomical images must firstbe carefully processed to clean up thedata, and this data must then be systematically analyzed to learn about the objects within it. AstroImageJ as a GUI-driven, easily installed, public-domain tool is a uniquelyaccessible tool for thisprocessing and analysis, allowing even non-specialist users to explore and visualizeastronomical data.Some features ofAstroImageJ:(as reported by Astrobites)Image calibration:generate master flat, dark, and bias framesImage arithmetic:combineimages viasubtraction, addition, division, multiplication, etc.Stack editing:easily perform operations on a series of imagesImage stabilization and image alignment featuresPrecise coordinate converters:calculate Heliocentric and Barycentric Julian DatesWCS coordinates:determine precisely where atelescope was pointed for an image by PlateSolving using Astronomy.netMacro and plugin support:write your own macrosMulti-aperture photometry

  13. Medical imaging technology

    CERN Document Server

    Haidekker, Mark A

    2013-01-01

    Biomedical imaging is a relatively young discipline that started with Conrad Wilhelm Roentgen’s discovery of the x-ray in 1885. X-ray imaging was rapidly adopted in hospitals around the world. However, it was the advent of computerized data and image processing that made revolutionary new imaging modalities possible. Today, cross-sections and three-dimensional reconstructions of the organs inside the human body is possible with unprecedented speed, detail and quality. This book provides an introduction into the principles of image formation of key medical imaging modalities: X-ray projection imaging, x-ray computed tomography, magnetic resonance imaging, ultrasound imaging, and radionuclide imaging. Recent developments in optical imaging are also covered. For each imaging modality, the introduction into the physical principles and sources of contrast is provided, followed by the methods of image formation, engineering aspects of the imaging devices, and a discussion of strengths and limitations of the modal...

  14. The Quest for Quality Electrocardiographic Recording

    Directory of Open Access Journals (Sweden)

    Javier García-Niebla

    2015-10-01

    Full Text Available For correct electrocardiography ECG diagnosis and interpretation, it is important not only to distinguish normal from pathological electrocardiograms, but also to ensure they have been properly recorded. Heden et al, reported that 2% of 11,000 EEGs analyzed showed interchanged electrode placement. Thus, if 300 million ECGs are performed annually in the world, 6 million are erroneously recorded. This figure could even triple if one includes other frequent mistakes, such as vertical displacement of precordial electrodes and the proximal placement of these on the limbs instead of the trunk. Few manuals on electrocardiography have devoted space to warn about the effects of ECG recordings that do not conform to standards, but it seems that this is changing. This issue of the journal contains two interesting articles by Rosen et al., who form part of the research group led by Dr. Adrian Baranchuk, which address the most common mistakes made in daily practice in relation to improper placement of limb and precordial electrodes, as well as tell-tale signs for their detection. In this editorial we will elaborate on certain issues directly related to possible errors on performing an ECG.

  15. A microcontroller-based portable electrocardiograph recorder.

    Science.gov (United States)

    Segura-Juárez, José J; Cuesta-Frau, David; Samblas-Pena, Luis; Aboy, Mateo

    2004-09-01

    We describe a low cost portable Holter design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.

  16. Annotating images by mining image search results

    NARCIS (Netherlands)

    Wang, X.J.; Zhang, L.; Li, X.; Ma, W.Y.

    2008-01-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search

  17. Automatic detection of blurred images in UAV image sets

    Science.gov (United States)

    Sieberth, Till; Wackrow, Rene; Chandler, Jim H.

    2016-12-01

    Unmanned aerial vehicles (UAV) have become an interesting and active research topic for photogrammetry. Current research is based on images acquired by an UAV, which have a high ground resolution and good spectral and radiometrical resolution, due to the low flight altitudes combined with a high resolution camera. UAV image flights are also cost effective and have become attractive for many applications including, change detection in small scale areas. One of the main problems preventing full automation of data processing of UAV imagery is the degradation effect of blur caused by camera movement during image acquisition. This can be caused by the normal flight movement of the UAV as well as strong winds, turbulence or sudden operator inputs. This blur disturbs the visual analysis and interpretation of the data, causes errors and can degrade the accuracy in automatic photogrammetric processing algorithms. The detection and removal of these images is currently achieved manually, which is both time consuming and prone to error, particularly for large image-sets. To increase the quality of data processing an automated process is necessary, which must be both reliable and quick. This paper describes the development of an automatic filtering process, which is based upon the quantification of blur in an image. Images with known blur are processed digitally to determine a quantifiable measure of image blur. The algorithm is required to process UAV images fast and reliably to relieve the operator from detecting blurred images manually. The newly developed method makes it possible to detect blur caused by linear camera displacement and is based on human detection of blur. Humans detect blurred images best by comparing it to other images in order to establish whether an image is blurred or not. The developed algorithm simulates this procedure by creating an image for comparison using image processing. Creating internally a comparable image makes the method independent of

  18. Image quality (IQ) guided multispectral image compression

    Science.gov (United States)

    Zheng, Yufeng; Chen, Genshe; Wang, Zhonghai; Blasch, Erik

    2016-05-01

    Image compression is necessary for data transportation, which saves both transferring time and storage space. In this paper, we focus on our discussion on lossy compression. There are many standard image formats and corresponding compression algorithms, for examples, JPEG (DCT -- discrete cosine transform), JPEG 2000 (DWT -- discrete wavelet transform), BPG (better portable graphics) and TIFF (LZW -- Lempel-Ziv-Welch). The image quality (IQ) of decompressed image will be measured by numerical metrics such as root mean square error (RMSE), peak signal-to-noise ratio (PSNR), and structural Similarity (SSIM) Index. Given an image and a specified IQ, we will investigate how to select a compression method and its parameters to achieve an expected compression. Our scenario consists of 3 steps. The first step is to compress a set of interested images by varying parameters and compute their IQs for each compression method. The second step is to create several regression models per compression method after analyzing the IQ-measurement versus compression-parameter from a number of compressed images. The third step is to compress the given image with the specified IQ using the selected compression method (JPEG, JPEG2000, BPG, or TIFF) according to the regressed models. The IQ may be specified by a compression ratio (e.g., 100), then we will select the compression method of the highest IQ (SSIM, or PSNR). Or the IQ may be specified by a IQ metric (e.g., SSIM = 0.8, or PSNR = 50), then we will select the compression method of the highest compression ratio. Our experiments tested on thermal (long-wave infrared) images (in gray scales) showed very promising results.

  19. Left ventricular lipoma with pseudoaneurysm-like appearance.

    Science.gov (United States)

    Kawarai, Shun-ichi; Yaginuma, Gen-ya; Abe, Kazuo; Hamasaki, Azumi; Ishikawa, Kazunori; Tanaka, Daizo

    2010-06-01

    We describe an extremely rare cardiac lipoma, with electrocardiographic changes in ST segments and T waves, suggesting ischemic heart disease. The abnormal electrocardiogram was identified during a routine physical examination of an asymptomatic 57-year-old man. Coronary angiography showed no stenotic or occlusive lesions in the coronary arteries except that the left anterior descending artery followed a winding course in the apical region. Left ventriculography revealed a pseudoaneurysm-like mass around the apical portion. Computed tomography and magnetic resonance imaging revealed a cardiac lipoma that communicated with the left ventricle and resembled a pseudoaneurysm. After complete resection of the lipoma and left ventricle patch plasty, the postoperative course was uneventful. Histologically, the tumor was an intramyocardiac lipoma with no evidence of malignancy. To our knowledge, we are the first to describe an intramyocardiac lipoma resembling a left ventricle pseudoaneurysm.

  20. Right Ventricular Involvement in either Anterior or Inferior Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Firoozeh Abtahi

    2016-06-01

    Full Text Available Background: Unlike left ventricular function, less attention has been paid to Right Ventricular (RV function after Myocardial Infarction (MI. Objectives: The current study aimed to compare RV function in patients with inferior and anterior MI. Patients and Methods: During the study period, 60 patients consecutively presented to the Emergency Department with chest pain were divided into two groups based on their electrocardiographic findings. Accordingly, 25 patients had inferior MI (IMI group and 35 ones had anterior MI (AMI group. Echocardiography was performed 48 hours after starting the standard therapy. Conventional echocardiographic parameters and Tissue Doppler Imaging (TDI measurements were acquired from the standard views. Student t-test and the chi-square test were respectively used for comparisons of the normally distributed continuous and categorical variables in the two groups. Besides, P < 0.05 was considered to be statistically significant.

  1. Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure

    International Nuclear Information System (INIS)

    Kipper, S.L.; Ashburn, W.L.; Norris, S.L.; Rimkus, D.S.; Dillon, W.A.

    1985-01-01

    Graded, sequential, rest/exercise, gold-195m, first-pass ventriculography and thallium-201 (Tl-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal T1-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. The authors suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combing Au-195m ventriculography and Tl-201 SPECT imaging into a single, noninvasive, diagnostic package

  2. Vaccine Images on Twitter: Analysis of What Images are Shared

    Science.gov (United States)

    Dredze, Mark

    2018-01-01

    Background Visual imagery plays a key role in health communication; however, there is little understanding of what aspects of vaccine-related images make them effective communication aids. Twitter, a popular venue for discussions related to vaccination, provides numerous images that are shared with tweets. Objective The objectives of this study were to understand how images are used in vaccine-related tweets and provide guidance with respect to the characteristics of vaccine-related images that correlate with the higher likelihood of being retweeted. Methods We collected more than one million vaccine image messages from Twitter and characterized various properties of these images using automated image analytics. We fit a logistic regression model to predict whether or not a vaccine image tweet was retweeted, thus identifying characteristics that correlate with a higher likelihood of being shared. For comparison, we built similar models for the sharing of vaccine news on Facebook and for general image tweets. Results Most vaccine-related images are duplicates (125,916/237,478; 53.02%) or taken from other sources, not necessarily created by the author of the tweet. Almost half of the images contain embedded text, and many include images of people and syringes. The visual content is highly correlated with a tweet’s textual topics. Vaccine image tweets are twice as likely to be shared as nonimage tweets. The sentiment of an image and the objects shown in the image were the predictive factors in determining whether an image was retweeted. Conclusions We are the first to study vaccine images on Twitter. Our findings suggest future directions for the study and use of vaccine imagery and may inform communication strategies around vaccination. Furthermore, our study demonstrates an effective study methodology for image analysis. PMID:29615386

  3. Vaccine Images on Twitter: Analysis of What Images are Shared.

    Science.gov (United States)

    Chen, Tao; Dredze, Mark

    2018-04-03

    Visual imagery plays a key role in health communication; however, there is little understanding of what aspects of vaccine-related images make them effective communication aids. Twitter, a popular venue for discussions related to vaccination, provides numerous images that are shared with tweets. The objectives of this study were to understand how images are used in vaccine-related tweets and provide guidance with respect to the characteristics of vaccine-related images that correlate with the higher likelihood of being retweeted. We collected more than one million vaccine image messages from Twitter and characterized various properties of these images using automated image analytics. We fit a logistic regression model to predict whether or not a vaccine image tweet was retweeted, thus identifying characteristics that correlate with a higher likelihood of being shared. For comparison, we built similar models for the sharing of vaccine news on Facebook and for general image tweets. Most vaccine-related images are duplicates (125,916/237,478; 53.02%) or taken from other sources, not necessarily created by the author of the tweet. Almost half of the images contain embedded text, and many include images of people and syringes. The visual content is highly correlated with a tweet's textual topics. Vaccine image tweets are twice as likely to be shared as nonimage tweets. The sentiment of an image and the objects shown in the image were the predictive factors in determining whether an image was retweeted. We are the first to study vaccine images on Twitter. Our findings suggest future directions for the study and use of vaccine imagery and may inform communication strategies around vaccination. Furthermore, our study demonstrates an effective study methodology for image analysis. ©Tao Chen, Mark Dredze. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 03.04.2018.

  4. The hemodynamic repercussions of the autonomic modulations in ...

    African Journals Online (AJOL)

    Igor Victorovich Lakhno

    2017-01-16

    Jan 16, 2017 ... autonomic balance, arterial and venous hemodynamic Doppler indices and CTG variables in case of nor- mal fetal ... score of decelerations. Results: The .... puter electrocardiographic system ''Cardiolab Baby Card” (Scien-.

  5. Image fusion in x-ray differential phase-contrast imaging

    Science.gov (United States)

    Haas, W.; Polyanskaya, M.; Bayer, F.; Gödel, K.; Hofmann, H.; Rieger, J.; Ritter, A.; Weber, T.; Wucherer, L.; Durst, J.; Michel, T.; Anton, G.; Hornegger, J.

    2012-02-01

    Phase-contrast imaging is a novel modality in the field of medical X-ray imaging. The pioneer method is the grating-based interferometry which has no special requirements to the X-ray source and object size. Furthermore, it provides three different types of information of an investigated object simultaneously - absorption, differential phase-contrast and dark-field images. Differential phase-contrast and dark-field images represent a completely new information which has not yet been investigated and studied in context of medical imaging. In order to introduce phase-contrast imaging as a new modality into medical environment the resulting information about the object has to be correctly interpreted. The three output images reflect different properties of the same object the main challenge is to combine and visualize these data in such a way that it diminish the information explosion and reduce the complexity of its interpretation. This paper presents an intuitive image fusion approach which allows to operate with grating-based phase-contrast images. It combines information of the three different images and provides a single image. The approach is implemented in a fusion framework which is aimed to support physicians in study and analysis. The framework provides the user with an intuitive graphical user interface allowing to control the fusion process. The example given in this work shows the functionality of the proposed method and the great potential of phase-contrast imaging in medical practice.

  6. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  7. Video retrieval by still-image analysis with ImageMiner

    Science.gov (United States)

    Kreyss, Jutta; Roeper, M.; Alshuth, Peter; Hermes, Thorsten; Herzog, Otthein

    1997-01-01

    The large amount of available multimedia information (e.g. videos, audio, images) requires efficient and effective annotation and retrieval methods. As videos start playing a more important role in the frame of multimedia, we want to make these available for content-based retrieval. The ImageMiner-System, which was developed at the University of Bremen in the AI group, is designed for content-based retrieval of single images by a new combination of techniques and methods from computer vision and artificial intelligence. In our approach to make videos available for retrieval in a large database of videos and images there are two necessary steps: First, the detection and extraction of shots from a video, which is done by a histogram based method and second, the construction of the separate frames in a shot to one still single images. This is performed by a mosaicing-technique. The resulting mosaiced image gives a one image visualization of the shot and can be analyzed by the ImageMiner-System. ImageMiner has been tested on several domains, (e.g. landscape images, technical drawings), which cover a wide range of applications.

  8. Mobile, Cloud, and Big Data Computing: Contributions, Challenges, and New Directions in Telecardiology

    Science.gov (United States)

    Hsieh, Jui-Chien; Li, Ai-Hsien; Yang, Chung-Chi

    2013-01-01

    Many studies have indicated that computing technology can enable off-site cardiologists to read patients’ electrocardiograph (ECG), echocardiography (ECHO), and relevant images via smart phones during pre-hospital, in-hospital, and post-hospital teleconsultation, which not only identifies emergency cases in need of immediate treatment, but also prevents the unnecessary re-hospitalizations. Meanwhile, several studies have combined cloud computing and mobile computing to facilitate better storage, delivery, retrieval, and management of medical files for telecardiology. In the future, the aggregated ECG and images from hospitals worldwide will become big data, which should be used to develop an e-consultation program helping on-site practitioners deliver appropriate treatment. With information technology, real-time tele-consultation and tele-diagnosis of ECG and images can be practiced via an e-platform for clinical, research, and educational purposes. While being devoted to promote the application of information technology onto telecardiology, we need to resolve several issues: (1) data confidentiality in the cloud, (2) data interoperability among hospitals, and (3) network latency and accessibility. If these challenges are overcome, tele-consultation will be ubiquitous, easy to perform, inexpensive, and beneficial. Most importantly, these services will increase global collaboration and advance clinical practice, education, and scientific research in cardiology. PMID:24232290

  9. Mobile, Cloud, and Big Data Computing: Contributions, Challenges, and New Directions in Telecardiology

    Directory of Open Access Journals (Sweden)

    Chung-Chi Yang

    2013-11-01

    Full Text Available Many studies have indicated that computing technology can enable off-site cardiologists to read patients’ electrocardiograph (ECG, echocardiography (ECHO, and relevant images via smart phones during pre-hospital, in-hospital, and post-hospital teleconsultation, which not only identifies emergency cases in need of immediate treatment, but also prevents the unnecessary re-hospitalizations. Meanwhile, several studies have combined cloud computing and mobile computing to facilitate better storage, delivery, retrieval, and management of medical files for telecardiology. In the future, the aggregated ECG and images from hospitals worldwide will become big data, which should be used to develop an e-consultation program helping on-site practitioners deliver appropriate treatment. With information technology, real-time tele-consultation and tele-diagnosis of ECG and images can be practiced via an e-platform for clinical, research, and educational purposes. While being devoted to promote the application of information technology onto telecardiology, we need to resolve several issues: (1 data confidentiality in the cloud, (2 data interoperability among hospitals, and (3 network latency and accessibility. If these challenges are overcome, tele-consultation will be ubiquitous, easy to perform, inexpensive, and beneficial. Most importantly, these services will increase global collaboration and advance clinical practice, education, and scientific research in cardiology.

  10. Mobile, cloud, and big data computing: contributions, challenges, and new directions in telecardiology.

    Science.gov (United States)

    Hsieh, Jui-Chien; Li, Ai-Hsien; Yang, Chung-Chi

    2013-11-13

    Many studies have indicated that computing technology can enable off-site cardiologists to read patients' electrocardiograph (ECG), echocardiography (ECHO), and relevant images via smart phones during pre-hospital, in-hospital, and post-hospital teleconsultation, which not only identifies emergency cases in need of immediate treatment, but also prevents the unnecessary re-hospitalizations. Meanwhile, several studies have combined cloud computing and mobile computing to facilitate better storage, delivery, retrieval, and management of medical files for telecardiology. In the future, the aggregated ECG and images from hospitals worldwide will become big data, which should be used to develop an e-consultation program helping on-site practitioners deliver appropriate treatment. With information technology, real-time tele-consultation and tele-diagnosis of ECG and images can be practiced via an e-platform for clinical, research, and educational purposes. While being devoted to promote the application of information technology onto telecardiology, we need to resolve several issues: (1) data confidentiality in the cloud, (2) data interoperability among hospitals, and (3) network latency and accessibility. If these challenges are overcome, tele-consultation will be ubiquitous, easy to perform, inexpensive, and beneficial. Most importantly, these services will increase global collaboration and advance clinical practice, education, and scientific research in cardiology.

  11. Stable image acquisition for mobile image processing applications

    Science.gov (United States)

    Henning, Kai-Fabian; Fritze, Alexander; Gillich, Eugen; Mönks, Uwe; Lohweg, Volker

    2015-02-01

    Today, mobile devices (smartphones, tablets, etc.) are widespread and of high importance for their users. Their performance as well as versatility increases over time. This leads to the opportunity to use such devices for more specific tasks like image processing in an industrial context. For the analysis of images requirements like image quality (blur, illumination, etc.) as well as a defined relative position of the object to be inspected are crucial. Since mobile devices are handheld and used in constantly changing environments the challenge is to fulfill these requirements. We present an approach to overcome the obstacles and stabilize the image capturing process such that image analysis becomes significantly improved on mobile devices. Therefore, image processing methods are combined with sensor fusion concepts. The approach consists of three main parts. First, pose estimation methods are used to guide a user moving the device to a defined position. Second, the sensors data and the pose information are combined for relative motion estimation. Finally, the image capturing process is automated. It is triggered depending on the alignment of the device and the object as well as the image quality that can be achieved under consideration of motion and environmental effects.

  12. Spectrally Consistent Satellite Image Fusion with Improved Image Priors

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Aanæs, Henrik; Jensen, Thomas B.S.

    2006-01-01

    Here an improvement to our previous framework for satellite image fusion is presented. A framework purely based on the sensor physics and on prior assumptions on the fused image. The contributions of this paper are two fold. Firstly, a method for ensuring 100% spectrally consistency is proposed......, even when more sophisticated image priors are applied. Secondly, a better image prior is introduced, via data-dependent image smoothing....

  13. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  14. Image quality dependence on image processing software in ...

    African Journals Online (AJOL)

    Image quality dependence on image processing software in computed radiography. ... Agfa CR readers use MUSICA software, and an upgrade with significantly different image ... Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  15. Long-term follow up after transcatheter closure of atrial septal defect and patent foramen ovale in adults

    Directory of Open Access Journals (Sweden)

    Jure Dolenc

    2014-01-01

    Full Text Available Background: The aim of our study was to define long-term electrocardiographic and echocardiographic changes and complications after transcatheter closure of atrial septal defect and patent foramen ovale in adults.Methods: The clinical, electrocardiographic and echocardiographic follow-up of 137 consecutive patients that underwent transcatheter closure of atrial septal defect (51 patients or patent foramen ovale (86 patients in a 10-year period was analyzed retrospectively.Results: In the patent foramen ovale group, we observed no significant postprocedural changes. There were no changes in heart rate, heart rhythm and PR or QRS duration in both groups. In the atrial septal defect group, we observed a leftward shift in the heart axis (p = 0.017, a decrease in the estimated systolic pulmonary artery pressure (p = 0.024, decreased tricuspid early diastolic flow velocity (p = 0.002, a decrease in the right chamber dimensions (p = 0.0004 and interventricular septal movement normalization (p < 0.0001. Most of the complications were mild and occurred early after the procedure. Three early serious complications were documented.Conclusions: No electrocardiographic or echocardiographic changes occurred after patent foramen ovale closure. Atrial septal defect closure is related to significant early morphological and hemodynamic improvement. Postprocedural complications are usually early and mild but serious late complications can occur. For that reason, long-term follow up is recommended in these patients.

  16. Echocardiographic evaluation during weaning from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Luciele Medianeira Schifelbain

    2011-01-01

    Full Text Available INTRODUCTION: Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. OBJECTIVES: To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T-tube; and comparing patient subgroups: success vs. failure in weaning. METHODS: Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T-tube. Pressure support ventilation vs. T-tube and weaning success vs. failure were compared using ANOVA and Student's t-test. The level of significance was p<0.05. RESULTS: Twenty-four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T-tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. CONCLUSION: No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T-tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients

  17. Parallel MR imaging.

    Science.gov (United States)

    Deshmane, Anagha; Gulani, Vikas; Griswold, Mark A; Seiberlich, Nicole

    2012-07-01

    Parallel imaging is a robust method for accelerating the acquisition of magnetic resonance imaging (MRI) data, and has made possible many new applications of MR imaging. Parallel imaging works by acquiring a reduced amount of k-space data with an array of receiver coils. These undersampled data can be acquired more quickly, but the undersampling leads to aliased images. One of several parallel imaging algorithms can then be used to reconstruct artifact-free images from either the aliased images (SENSE-type reconstruction) or from the undersampled data (GRAPPA-type reconstruction). The advantages of parallel imaging in a clinical setting include faster image acquisition, which can be used, for instance, to shorten breath-hold times resulting in fewer motion-corrupted examinations. In this article the basic concepts behind parallel imaging are introduced. The relationship between undersampling and aliasing is discussed and two commonly used parallel imaging methods, SENSE and GRAPPA, are explained in detail. Examples of artifacts arising from parallel imaging are shown and ways to detect and mitigate these artifacts are described. Finally, several current applications of parallel imaging are presented and recent advancements and promising research in parallel imaging are briefly reviewed. Copyright © 2012 Wiley Periodicals, Inc.

  18. Medical Imaging System

    Science.gov (United States)

    1991-01-01

    The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

  19. Retinal imaging and image analysis

    NARCIS (Netherlands)

    Abramoff, M.D.; Garvin, Mona K.; Sonka, Milan

    2010-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of

  20. Imaging of melorheostosis : emphasis on MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hyon; Lee, Sang Kwon; Kim, Jong Yeol; Shin, Tae Bum; Kim, Young Whan; Pak, Hyo Yong; Kim, Yong Joo; Kang, Duk Sik [College of Medicine, Kyungpook National University, Taegu (Korea, Republic of); Lee, Yeong Hwan [College of Medicine, Catholic University of Taegu-Hyosung, Taegu (Korea, Republic of); Byun, Kyung Hwan [Kumi CHA General Hospital, College of Medicine, Pochon CHA University, Kumi (Korea, Republic of)

    2000-02-01

    To evaluate the usefulness of various radiographic imaging modalities in the diagnosis and characterization of melorheostosis. We retrospectively evaluated the plain film (n=3D8), computed tomographic (CT) imaging (n=3D5) and magnetic resonance (MR) imaging (n=3D5) findings of eight patients with melorheostosis diagnosed by bone biopsy (n=3D4) and characteristic radiographic findings (n=3D8). MR images were obtained with a 1.5-T scanner focused on the region of maximal radiographic abnormality. Pulse sequences include T1-weighted SE. T2-weighted fast SE (n=3D5) and postcontrast imaging (n=3D4). In order to define subtle enhancement of the lesions, subtraction MR images were obtained in one case. Imaging findings were analyzed with particular emphasis on the distribution lesions along the sclerotome, differential radiographic findings between diaphyseal and metaepiphyseal lesions of the long bones, as seen on plain radiographs, and the density and signal characteristics of hyperostotic lesions, as seen on CT and MR images. Characteristic distribution along the sclerotome was identified in five of eight cases mainly along C6 and 7 (n=3D2) and L3, 4 and 5 (n=3D3) sclerotomes. In diaphyseal melorherostosis (8/8), a characteristic finding, i.e., a wax flowing down from the candle, was identified on plain radiographs. In all three patients with metaepiphyseal melorheostosis (3/8), multiple round or oval hyperostotic lesions were seen in the epipysis and metaphysis of the long bones. On CT, the marrow cavity was partly obliterated by hyperostotic lesions in all five patients with endosteal hyperostosis. Among these, central ground glass opacity with a sclerotic rim was seen in three patients. Periosteal hyperostosis was seen in two of five cases, being visualized as irregular excrescence in the periosteal region and surrounding soft tissue. Individual hyperostosis was visualized as hypointense on T1-weighted images and as a hyperintense center with a surrounding

  1. COMPARISON OF IMAGE ENHANCEMENT METHODS FOR CHROMOSOME KARYOTYPE IMAGE ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    Dewa Made Sri Arsa

    2017-02-01

    Full Text Available The chromosome is a set of DNA structure that carry information about our life. The information can be obtained through Karyotyping. The process requires a clear image so the chromosome can be evaluate well. Preprocessing have to be done on chromosome images that is image enhancement. The process starts with image background removing. The image will be cleaned background color. The next step is image enhancement. This paper compares several methods for image enhancement. We evaluate some method in image enhancement like Histogram Equalization (HE, Contrast-limiting Adaptive Histogram Equalization (CLAHE, Histogram Equalization with 3D Block Matching (HE+BM3D, and basic image enhancement, unsharp masking. We examine and discuss the best method for enhancing chromosome image. Therefore, to evaluate the methods, the original image was manipulated by the addition of some noise and blur. Peak Signal-to-noise Ratio (PSNR and Structural Similarity Index (SSIM are used to examine method performance. The output of enhancement method will be compared with result of Professional software for karyotyping analysis named Ikaros MetasystemT M . Based on experimental results, HE+BM3D method gets a stable result on both scenario noised and blur image.

  2. Quantitative assessment of dynamic PET imaging data in cancer imaging.

    Science.gov (United States)

    Muzi, Mark; O'Sullivan, Finbarr; Mankoff, David A; Doot, Robert K; Pierce, Larry A; Kurland, Brenda F; Linden, Hannah M; Kinahan, Paul E

    2012-11-01

    Clinical imaging in positron emission tomography (PET) is often performed using single-time-point estimates of tracer uptake or static imaging that provides a spatial map of regional tracer concentration. However, dynamic tracer imaging can provide considerably more information about in vivo biology by delineating both the temporal and spatial pattern of tracer uptake. In addition, several potential sources of error that occur in static imaging can be mitigated. This review focuses on the application of dynamic PET imaging to measuring regional cancer biologic features and especially in using dynamic PET imaging for quantitative therapeutic response monitoring for cancer clinical trials. Dynamic PET imaging output parameters, particularly transport (flow) and overall metabolic rate, have provided imaging end points for clinical trials at single-center institutions for years. However, dynamic imaging poses many challenges for multicenter clinical trial implementations from cross-center calibration to the inadequacy of a common informatics infrastructure. Underlying principles and methodology of PET dynamic imaging are first reviewed, followed by an examination of current approaches to dynamic PET image analysis with a specific case example of dynamic fluorothymidine imaging to illustrate the approach. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Imaging angiogenesis.

    Science.gov (United States)

    Charnley, Natalie; Donaldson, Stephanie; Price, Pat

    2009-01-01

    There is a need for direct imaging of effects on tumor vasculature in assessment of response to antiangiogenic drugs and vascular disrupting agents. Imaging tumor vasculature depends on differences in permeability of vasculature of tumor and normal tissue, which cause changes in penetration of contrast agents. Angiogenesis imaging may be defined in terms of measurement of tumor perfusion and direct imaging of the molecules involved in angiogenesis. In addition, assessment of tumor hypoxia will give an indication of tumor vasculature. The range of imaging techniques available for these processes includes positron emission tomography (PET), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), perfusion computed tomography (CT), and ultrasound (US).

  4. X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging

    International Nuclear Information System (INIS)

    McBain, Catherine A.; Henry, Ann M.; Sykes, Jonathan; Amer, Ali; Marchant, Tom; Moore, Christopher M.; Davies, Julie; Stratford, Julia; McCarthy, Claire; Porritt, Bridget; Williams, Peter; Khoo, Vincent S.; Price, Pat

    2006-01-01

    Purpose: X-ray volumetric imaging (XVI) for the first time allows for the on-treatment acquisition of three-dimensional (3D) kV cone beam computed tomography (CT) images. Clinical imaging using the Synergy System (Elekta, Crawley, UK) commenced in July 2003. This study evaluated image quality and dose delivered and assessed clinical utility for treatment verification at a range of anatomic sites. Methods and Materials: Single XVIs were acquired from 30 patients undergoing radiotherapy for tumors at 10 different anatomic sites. Patients were imaged in their setup position. Radiation doses received were measured using TLDs on the skin surface. The utility of XVI in verifying target volume coverage was qualitatively assessed by experienced clinicians. Results: X-ray volumetric imaging acquisition was completed in the treatment position at all anatomic sites. At sites where a full gantry rotation was not possible, XVIs were reconstructed from projection images acquired from partial rotations. Soft-tissue definition of organ boundaries allowed direct assessment of 3D target volume coverage at all sites. Individual image quality depended on both imaging parameters and patient characteristics. Radiation dose ranged from 0.003 Gy in the head to 0.03 Gy in the pelvis. Conclusions: On-treatment XVI provided 3D verification images with soft-tissue definition at all anatomic sites at acceptably low radiation doses. This technology sets a new standard in treatment verification and will facilitate novel adaptive radiotherapy techniques

  5. Evaluation of multimodality imaging using image fusion with ultrasound tissue elasticity imaging in an experimental animal model.

    Science.gov (United States)

    Paprottka, P M; Zengel, P; Cyran, C C; Ingrisch, M; Nikolaou, K; Reiser, M F; Clevert, D A

    2014-01-01

    To evaluate the ultrasound tissue elasticity imaging by comparison to multimodality imaging using image fusion with Magnetic Resonance Imaging (MRI) and conventional grey scale imaging with additional elasticity-ultrasound in an experimental small-animal-squamous-cell carcinoma-model for the assessment of tissue morphology. Human hypopharynx carcinoma cells were subcutaneously injected into the left flank of 12 female athymic nude rats. After 10 days (SD ± 2) of subcutaneous tumor growth, sonographic grey scale including elasticity imaging and MRI measurements were performed using a high-end ultrasound system and a 3T MR. For image fusion the contrast-enhanced MRI DICOM data set was uploaded in the ultrasonic device which has a magnetic field generator, a linear array transducer (6-15 MHz) and a dedicated software package (GE Logic E9), that can detect transducers by means of a positioning system. Conventional grey scale and elasticity imaging were integrated in the image fusion examination. After successful registration and image fusion the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologist using a modified Tsukuba Elasticity score. The colors "red and green" are assigned for an area of soft tissue, "blue" indicates hard tissue. In all cases a successful image fusion and plan registration with MRI and ultrasound imaging including grey scale and elasticity imaging was possible. The mean tumor volume based on caliper measurements in 3 dimensions was ~323 mm3. 4/12 rats were evaluated with Score I, 5/12 rates were evaluated with Score II, 3/12 rates were evaluated with Score III. There was a close correlation in the fused MRI with existing small necrosis in the tumor. None of the scored II or III lesions was visible by conventional grey scale. The comparison of ultrasound tissue elasticity imaging enables a

  6. Left ventricular hypertrophy and risk of fatal and non-fatal stroke EUROSTROKE: a collaborative study among research centres in Europe

    NARCIS (Netherlands)

    M.L. Bots (Michiel); J. Tuomilehto; D.E. Grobbee (Diederick); P.J. Koudstaal (Peter Jan); Y. Nikitin; J.T. Salonen; P.C. Elwood; S. Malyutina; A. Freire de Concalves; J. Sivenius; A. di Carlo; P. Lagiou

    2002-01-01

    textabstractBACKGROUND: This study investigated the association between electrocardiographically assessed left ventricular hypertrophy (LVH) and fatal, non-fatal, haemorrhagic and ischaemic stroke in four European cohorts participating in EUROSTROKE. METHODS: EUROSTROKE is a

  7. Perfil eletrocardiográfico dos atletas integrantes da equipe brasileira dos XI jogos paraolímpicos de Sydney 2000 Electrocardiographic profile of the Brazilian team in the Sydney 2000 paralympic games

    Directory of Open Access Journals (Sweden)

    Marcelo Bichels Leitão

    2002-06-01

    Full Text Available O esporte paraolímpico tem despertado o interesse da comunidade científica devido à diversidade de situações encontradas em seus atletas. Contudo, existe atualmente uma carência de informações sobre parâmetros clínicos e fisiológicos referentes a atletas portadores de deficiências. Este trabalho tem como objetivo descrever as características eletrocardiográficas encontradas nos atletas da delegação brasileira que participou dos XI Jogos Paraolímpicos de Sydney 2000. Foram avaliados 60 atletas, sendo 50 do sexo masculino e 10 do sexo feminino. Todos estes atletas foram submetidos a uma anamnese e a um exame físico, seguidos de eletrocardiograma de repouso (ECG, teste ergométrico (TE e quando necessário de ecocardiograma (ECOC. De acordo com os resultados do ECG os indivíduos foram classificados em uma de três situações: ECG normal (N = 31, ECG de Atleta (N = 26 ou ECG anormal (N = 3. Não foram observados eventos anormais no TE de nenhum atleta. Os três indivíduos que apresentaram ECG anormal foram submetidos a ECOC que se mostrou normal em todas as situações.Paralympic sports have attracted the interest of the scientific community as a consequence of the diversity of situations found in such athletes. However, there still is a scarcity of information about clinical and physiological parameters of disabled athletes. This study describes the electrocardiographic characteristics observed in the athletes of Brazilian team that participated in the Sydney 2000 Paralympic Games. 60 subjects were evaluated, 10 female and 50 male. All of them were submitted to an anamnesis and a physical examination, followed by a rest electrocardiogram (ECG, an exercise test (ET, and when needed, they were also submitted to an echocardiography (ECOC. According to the ECG results, subjects were classified as normal ECG (N = 31, athlete ECG (N = 26 or altered ECG (N = 3. No abnormalities were observed on ET. The three subjects who showed

  8. Matching rendered and real world images by digital image processing

    Science.gov (United States)

    Mitjà, Carles; Bover, Toni; Bigas, Miquel; Escofet, Jaume

    2010-05-01

    Recent advances in computer-generated images (CGI) have been used in commercial and industrial photography providing a broad scope in product advertising. Mixing real world images with those rendered from virtual space software shows a more or less visible mismatching between corresponding image quality performance. Rendered images are produced by software which quality performance is only limited by the resolution output. Real world images are taken with cameras with some amount of image degradation factors as lens residual aberrations, diffraction, sensor low pass anti aliasing filters, color pattern demosaicing, etc. The effect of all those image quality degradation factors can be characterized by the system Point Spread Function (PSF). Because the image is the convolution of the object by the system PSF, its characterization shows the amount of image degradation added to any taken picture. This work explores the use of image processing to degrade the rendered images following the parameters indicated by the real system PSF, attempting to match both virtual and real world image qualities. The system MTF is determined by the slanted edge method both in laboratory conditions and in the real picture environment in order to compare the influence of the working conditions on the device performance; an approximation to the system PSF is derived from the two measurements. The rendered images are filtered through a Gaussian filter obtained from the taking system PSF. Results with and without filtering are shown and compared measuring the contrast achieved in different final image regions.

  9. Accuracy and effectiveness of self-gating signals in free-breathing three-dimensional cardiac cine magnetic resonance imaging

    Science.gov (United States)

    Li, Shuo; Wang, Lei; Zhu, Yan-Chun; Yang, Jie; Xie, Yao-Qin; Fu, Nan; Wang, Yi; Gao, Song

    2016-12-01

    Conventional multiple breath-hold two-dimensional (2D) balanced steady-state free precession (SSFP) presents many difficulties in cardiac cine magnetic resonance imaging (MRI). Recently, a self-gated free-breathing three-dimensional (3D) SSFP technique has been proposed as an alternative in many studies. However, the accuracy and effectiveness of self-gating signals have been barely studied before. Since self-gating signals are crucially important in image reconstruction, a systematic study of self-gating signals and comparison with external monitored signals are needed. Previously developed self-gated free-breathing 3D SSFP techniques are used on twenty-eight healthy volunteers. Both electrocardiographic (ECG) and respiratory bellow signals are also acquired during the scan as external signals. Self-gating signal and external signal are compared by trigger and gating window. Gating window is proposed to evaluate the accuracy and effectiveness of respiratory self-gating signal. Relative deviation of the trigger and root-mean-square-deviation of the cycle duration are calculated. A two-tailed paired t-test is used to identify the difference between self-gating and external signals. A Wilcoxon signed rank test is used to identify the difference between peak and valley self-gating triggers. The results demonstrate an excellent correlation (P = 0, R > 0.99) between self-gating and external triggers. Wilcoxon signed rank test shows that there is no significant difference between peak and valley self-gating triggers for both cardiac (H = 0, P > 0.10) and respiratory (H = 0, P > 0.44) motions. The difference between self-gating and externally monitored signals is not significant (two-tailed paired-sample t-test: H = 0, P > 0.90). The self-gating signals could demonstrate cardiac and respiratory motion accurately and effectively as ECG and respiratory bellow. The difference between the two methods is not significant and can be explained. Furthermore, few ECG trigger errors

  10. Quantum Image Encryption Algorithm Based on Image Correlation Decomposition

    Science.gov (United States)

    Hua, Tianxiang; Chen, Jiamin; Pei, Dongju; Zhang, Wenquan; Zhou, Nanrun

    2015-02-01

    A novel quantum gray-level image encryption and decryption algorithm based on image correlation decomposition is proposed. The correlation among image pixels is established by utilizing the superposition and measurement principle of quantum states. And a whole quantum image is divided into a series of sub-images. These sub-images are stored into a complete binary tree array constructed previously and then randomly performed by one of the operations of quantum random-phase gate, quantum revolving gate and Hadamard transform. The encrypted image can be obtained by superimposing the resulting sub-images with the superposition principle of quantum states. For the encryption algorithm, the keys are the parameters of random phase gate, rotation angle, binary sequence and orthonormal basis states. The security and the computational complexity of the proposed algorithm are analyzed. The proposed encryption algorithm can resist brute force attack due to its very large key space and has lower computational complexity than its classical counterparts.

  11. Corner-point criterion for assessing nonlinear image processing imagers

    Science.gov (United States)

    Landeau, Stéphane; Pigois, Laurent; Foing, Jean-Paul; Deshors, Gilles; Swiathy, Greggory

    2017-10-01

    Range performance modeling of optronics imagers attempts to characterize the ability to resolve details in the image. Today, digital image processing is systematically used in conjunction with the optoelectronic system to correct its defects or to exploit tiny detection signals to increase performance. In order to characterize these processing having adaptive and non-linear properties, it becomes necessary to stimulate the imagers with test patterns whose properties are similar to the actual scene image ones, in terms of dynamic range, contours, texture and singular points. This paper presents an approach based on a Corner-Point (CP) resolution criterion, derived from the Probability of Correct Resolution (PCR) of binary fractal patterns. The fundamental principle lies in the respectful perception of the CP direction of one pixel minority value among the majority value of a 2×2 pixels block. The evaluation procedure considers the actual image as its multi-resolution CP transformation, taking the role of Ground Truth (GT). After a spatial registration between the degraded image and the original one, the degradation is statistically measured by comparing the GT with the degraded image CP transformation, in terms of localized PCR at the region of interest. The paper defines this CP criterion and presents the developed evaluation techniques, such as the measurement of the number of CP resolved on the target, the transformation CP and its inverse transform that make it possible to reconstruct an image of the perceived CPs. Then, this criterion is compared with the standard Johnson criterion, in the case of a linear blur and noise degradation. The evaluation of an imaging system integrating an image display and a visual perception is considered, by proposing an analysis scheme combining two methods: a CP measurement for the highly non-linear part (imaging) with real signature test target and conventional methods for the more linear part (displaying). The application to

  12. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  13. Nuclear imaging in the realm of medical imaging

    International Nuclear Information System (INIS)

    Deconinck, Frank

    2003-01-01

    In medical imaging, information concerning the anatomy or biological processes of a patient is detected and presented on film or screen for interpretation by a reader. The information flow from patient to reader optimally implies: - the emission, transmission or reflection of information carriers, typically photons or sound waves, which have to be correctly modulated by patient information through interactions in the patient; - their detection by adequate imaging equipment preserving essential spectral, spatial and/or temporal information; - the presentation of the information in the most perceivable way; - the observation by an unbiased and trained expert. In reality, only an approximation to this optimal situation is achieved. It is the goal of R and D in the medical imaging field to approach the optimum as much as possible within societal constraints such as patient risk and comfort, economics, etc. First, the basic physical concepts underlying the imaging process will be introduced. Different imaging modalities will then be situated in the realm of medical imaging with some emphasis on nuclear imaging

  14. Image city

    DEFF Research Database (Denmark)

    2003-01-01

    Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities.......Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities....

  15. Mining for diagnostic information in body surface potential maps: A comparison of feature selection techniques

    Directory of Open Access Journals (Sweden)

    McCullagh Paul J

    2005-09-01

    Full Text Available Abstract Background In body surface potential mapping, increased spatial sampling is used to allow more accurate detection of a cardiac abnormality. Although diagnostically superior to more conventional electrocardiographic techniques, the perceived complexity of the Body Surface Potential Map (BSPM acquisition process has prohibited its acceptance in clinical practice. For this reason there is an interest in striking a compromise between the minimum number of electrocardiographic recording sites required to sample the maximum electrocardiographic information. Methods In the current study, several techniques widely used in the domains of data mining and knowledge discovery have been employed to mine for diagnostic information in 192 lead BSPMs. In particular, the Single Variable Classifier (SVC based filter and Sequential Forward Selection (SFS based wrapper approaches to feature selection have been implemented and evaluated. Using a set of recordings from 116 subjects, the diagnostic ability of subsets of 3, 6, 9, 12, 24 and 32 electrocardiographic recording sites have been evaluated based on their ability to correctly asses the presence or absence of Myocardial Infarction (MI. Results It was observed that the wrapper approach, using sequential forward selection and a 5 nearest neighbour classifier, was capable of choosing a set of 24 recording sites that could correctly classify 82.8% of BSPMs. Although the filter method performed slightly less favourably, the performance was comparable with a classification accuracy of 79.3%. In addition, experiments were conducted to show how (a features chosen using the wrapper approach were specific to the classifier used in the selection model, and (b lead subsets chosen were not necessarily unique. Conclusion It was concluded that both the filter and wrapper approaches adopted were suitable for guiding the choice of recording sites useful for determining the presence of MI. It should be noted however

  16. Analysis of image plane's Illumination in Image-forming System

    International Nuclear Information System (INIS)

    Duan Lihua; Zeng Yan'an; Zhang Nanyangsheng; Wang Zhiguo; Yin Shiliang

    2011-01-01

    In the detection of optical radiation, the detecting accuracy is affected by optic power distribution of the detector's surface to a large extent. In addition, in the image-forming system, the quality of the image is greatly determined by the uniformity of the image's illumination distribution. However, in the practical optical system, affected by the factors such as field of view, false light and off axis and so on, the distribution of the image's illumination tends to be non uniform, so it is necessary to discuss the image plane's illumination in image-forming systems. In order to analyze the characteristics of the image-forming system at a full range, on the basis of photometry, the formulas to calculate the illumination of the imaging plane have been summarized by the numbers. Moreover, the relationship between the horizontal offset of the light source and the illumination of the image has been discussed in detail. After that, the influence of some key factors such as aperture angle, off-axis distance and horizontal offset on illumination of the image has been brought forward. Through numerical simulation, various theoretical curves of those key factors have been given. The results of the numerical simulation show that it is recommended to aggrandize the diameter of the exit pupil to increase the illumination of the image. The angle of view plays a negative role in the illumination distribution of the image, that is, the uniformity of the illumination distribution can be enhanced by compressing the angle of view. Lastly, it is proved that telecentric optical design is an effective way to advance the uniformity of the illumination distribution.

  17. Fast processing of foreign fiber images by image blocking

    OpenAIRE

    Yutao Wu; Daoliang Li; Zhenbo Li; Wenzhu Yang

    2014-01-01

    In the textile industry, it is always the case that cotton products are constitutive of many types of foreign fibers which affect the overall quality of cotton products. As the foundation of the foreign fiber automated inspection, image process exerts a critical impact on the process of foreign fiber identification. This paper presents a new approach for the fast processing of foreign fiber images. This approach includes five main steps, image block, image pre-decision, image background extra...

  18. Image processing on the image with pixel noise bits removed

    Science.gov (United States)

    Chuang, Keh-Shih; Wu, Christine

    1992-06-01

    Our previous studies used statistical methods to assess the noise level in digital images of various radiological modalities. We separated the pixel data into signal bits and noise bits and demonstrated visually that the removal of the noise bits does not affect the image quality. In this paper we apply image enhancement techniques on noise-bits-removed images and demonstrate that the removal of noise bits has no effect on the image property. The image processing techniques used are gray-level look up table transformation, Sobel edge detector, and 3-D surface display. Preliminary results show no noticeable difference between original image and noise bits removed image using look up table operation and Sobel edge enhancement. There is a slight enhancement of the slicing artifact in the 3-D surface display of the noise bits removed image.

  19. Hybrid Image Fusion for Sharpness Enhancement of Multi-Spectral Lunar Images

    Science.gov (United States)

    Awumah, Anna; Mahanti, Prasun; Robinson, Mark

    2016-10-01

    Image fusion enhances the sharpness of a multi-spectral (MS) image by incorporating spatial details from a higher-resolution panchromatic (Pan) image [1,2]. Known applications of image fusion for planetary images are rare, although image fusion is well-known for its applications to Earth-based remote sensing. In a recent work [3], six different image fusion algorithms were implemented and their performances were verified with images from the Lunar Reconnaissance Orbiter (LRO) Camera. The image fusion procedure obtained a high-resolution multi-spectral (HRMS) product from the LRO Narrow Angle Camera (used as Pan) and LRO Wide Angle Camera (used as MS) images. The results showed that the Intensity-Hue-Saturation (IHS) algorithm results in a high-spatial quality product while the Wavelet-based image fusion algorithm best preserves spectral quality among all the algorithms. In this work we show the results of a hybrid IHS-Wavelet image fusion algorithm when applied to LROC MS images. The hybrid method provides the best HRMS product - both in terms of spatial resolution and preservation of spectral details. Results from hybrid image fusion can enable new science and increase the science return from existing LROC images.[1] Pohl, Cle, and John L. Van Genderen. "Review article multisensor image fusion in remote sensing: concepts, methods and applications." International journal of remote sensing 19.5 (1998): 823-854.[2] Zhang, Yun. "Understanding image fusion." Photogramm. Eng. Remote Sens 70.6 (2004): 657-661.[3] Mahanti, Prasun et al. "Enhancement of spatial resolution of the LROC Wide Angle Camera images." Archives, XXIII ISPRS Congress Archives (2016).

  20. Rapid MR imaging

    International Nuclear Information System (INIS)

    Edelman, R.R.; Buxton, R.B.; Brady, T.J.

    1988-01-01

    Conventional magnetic resonance (MR) imaging methods typically require several minutes to produce an image, but the periods of respiration, cardiac motion and peristalsis are on the order of seconds or less. The need to reduce motion artifact, as well as the need to reduce imaging time for patient comfort and efficiency, have provided a strong impetus for the development of rapid imaging methods. For abdominal imaging, motion artifacts due to respiration can be significantly reduced by collecting the entire image during one breath hold. For other applications, such as following the kinetics of administered contrast agents, rapid imaging is essential to achieve adequate time resolution. A shorter imaging time entails a cost in image signal/noise (S/N), but improvements in recent years in magnet homogeneity, gradient and radiofrequency coil design have led to steady improvements in S/N and consequently in image quality. For many chemical applications the available S/N is greater than needed, and a trade-off of lower S/N for a shorter imaging time is acceptable. In this chapter, the authors consider the underlying principles of rapid imaging as well as clinical applications of these methods. The bulk of this review concentrates on short TR imaging, but methods that provide for a more modest decrease in imaging time as well as or those that dramatically shorten the imaging time to tens of milliseconds are also discussed

  1. Molecular photoacoustic imaging

    Directory of Open Access Journals (Sweden)

    Frogh Jafarian Dehkordi

    2015-04-01

    Full Text Available Background: Hybrid imaging modalities which simultaneously benefit from capabilities of combined modalities provides an opportunity to modify quality of the images which can be obtained by each of the combined imaging systems. One of the imaging modalities, emerged in medical research area as a hybrid of ultrasound imaging and optical imaging, is photoacoustic imaging which apply ultrasound wave generated by tissue, after receiving laser pulse, to produce medical images. Materials and Methods: In this review, using keywords such as photoacoustic, optoacoustic, laser-ultrasound, thermoacoustic at databases such as PubMed and ISI, studies performed in the field of photoacoustic and related findings were evaluated. Results: Photoacoustic imaging, acquiring images with high contrast and desired resolution, provides an opportunity to perform physiologic and anatomic studies. Because this technique does not use ionizing radiation, it is not restricted by the limitation of the ionizing-based imaging systems therefore it can be used noninvasively to make images from cell, vessels, whole body imaging of the animal and distinguish tumor from normal tissue. Conclusion: Photoacoustic imaging is a new method in preclinical researches which can be used in various physiologic and anatomic studies. This method, because of application of non-ionizing radiation, may resolve limitation of radiation based method in diagnostic assessments.

  2. Image perception and image processing

    International Nuclear Information System (INIS)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures. (orig.) [de

  3. Image perception and image processing

    Energy Technology Data Exchange (ETDEWEB)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures.

  4. Image-adaptive and robust digital wavelet-domain watermarking for images

    Science.gov (United States)

    Zhao, Yi; Zhang, Liping

    2018-03-01

    We propose a new frequency domain wavelet based watermarking technique. The key idea of our scheme is twofold: multi-tier solution representation of image and odd-even quantization embedding/extracting watermark. Because many complementary watermarks need to be hidden, the watermark image designed is image-adaptive. The meaningful and complementary watermark images was embedded into the original image (host image) by odd-even quantization modifying coefficients, which was selected from the detail wavelet coefficients of the original image, if their magnitudes are larger than their corresponding Just Noticeable Difference thresholds. The tests show good robustness against best-known attacks such as noise addition, image compression, median filtering, clipping as well as geometric transforms. Further research may improve the performance by refining JND thresholds.

  5. Optimal image resolution for digital storage of radiotherapy-planning images

    International Nuclear Information System (INIS)

    Baba, Yuji; Furusawa, Mitsuhiro; Murakami, Ryuji; Baba, Takashi; Yokoyama, Toshimi; Nishimura, Ryuichi; Takahashi, Mutsumasa

    1998-01-01

    Purpose: To evaluate the quality of digitized radiation-planning images at different resolution and to determine the optimal resolution for digital storage. Methods and Materials: Twenty-five planning films were scanned and digitized using a film scanner at a resolution of 72 dots per inch (dpi) with 8-bit depth. The resolution of scanned images was reduced to 48, 36, 24, and 18 dpi using computer software. Image qualities of these five images (72, 48, 36, 24, and 18 dpi) were evaluated and given scores (4 = excellent; 3 = good; 2 = fair; and 1 = poor) by three radiation oncologists. An image data compression algorithm by the Joint Photographic Experts Group (JPEG) (not reversible and some information will be lost) was also evaluated. Results: The scores of digitized images with 72, 48, 36, 24, and 17 dpi resolution were 3.8 ± 0.3, 3.5 ± 0.3, 3.3 ± 0.5, 2.7 ± 0.5, and 1.6 ± 0.3, respectively. The quality of 36-dpi images were definitely worse compared to 72-dpi images, but were good enough as planning films. Digitized planning images with 72- and 36-dpi resolution requires about 800 and 200 KBytes, respectively. The JPEG compression algorithm produces little degradation in 36-dpi images at compression ratios of 5:1. Conclusion: The quality of digitized images with 36-dpi resolution was good enough as radiation-planning images and required 200 KBytes/image

  6. Quantitative imaging features: extension of the oncology medical image database

    Science.gov (United States)

    Patel, M. N.; Looney, P. T.; Young, K. C.; Halling-Brown, M. D.

    2015-03-01

    Radiological imaging is fundamental within the healthcare industry and has become routinely adopted for diagnosis, disease monitoring and treatment planning. With the advent of digital imaging modalities and the rapid growth in both diagnostic and therapeutic imaging, the ability to be able to harness this large influx of data is of paramount importance. The Oncology Medical Image Database (OMI-DB) was created to provide a centralized, fully annotated dataset for research. The database contains both processed and unprocessed images, associated data, and annotations and where applicable expert determined ground truths describing features of interest. Medical imaging provides the ability to detect and localize many changes that are important to determine whether a disease is present or a therapy is effective by depicting alterations in anatomic, physiologic, biochemical or molecular processes. Quantitative imaging features are sensitive, specific, accurate and reproducible imaging measures of these changes. Here, we describe an extension to the OMI-DB whereby a range of imaging features and descriptors are pre-calculated using a high throughput approach. The ability to calculate multiple imaging features and data from the acquired images would be valuable and facilitate further research applications investigating detection, prognosis, and classification. The resultant data store contains more than 10 million quantitative features as well as features derived from CAD predictions. Theses data can be used to build predictive models to aid image classification, treatment response assessment as well as to identify prognostic imaging biomarkers.

  7. Enhancement system of nighttime infrared video image and visible video image

    Science.gov (United States)

    Wang, Yue; Piao, Yan

    2016-11-01

    Visibility of Nighttime video image has a great significance for military and medicine areas, but nighttime video image has so poor quality that we can't recognize the target and background. Thus we enhance the nighttime video image by fuse infrared video image and visible video image. According to the characteristics of infrared and visible images, we proposed improved sift algorithm andαβ weighted algorithm to fuse heterologous nighttime images. We would deduced a transfer matrix from improved sift algorithm. The transfer matrix would rapid register heterologous nighttime images. And theαβ weighted algorithm can be applied in any scene. In the video image fusion system, we used the transfer matrix to register every frame and then used αβ weighted method to fuse every frame, which reached the time requirement soft video. The fused video image not only retains the clear target information of infrared video image, but also retains the detail and color information of visible video image and the fused video image can fluency play.

  8. An enhanced approach for biomedical image restoration using image fusion techniques

    Science.gov (United States)

    Karam, Ghada Sabah; Abbas, Fatma Ismail; Abood, Ziad M.; Kadhim, Kadhim K.; Karam, Nada S.

    2018-05-01

    Biomedical image is generally noisy and little blur due to the physical mechanisms of the acquisition process, so one of the common degradations in biomedical image is their noise and poor contrast. The idea of biomedical image enhancement is to improve the quality of the image for early diagnosis. In this paper we are using Wavelet Transformation to remove the Gaussian noise from biomedical images: Positron Emission Tomography (PET) image and Radiography (Radio) image, in different color spaces (RGB, HSV, YCbCr), and we perform the fusion of the denoised images resulting from the above denoising techniques using add image method. Then some quantive performance metrics such as signal -to -noise ratio (SNR), peak signal-to-noise ratio (PSNR), and Mean Square Error (MSE), etc. are computed. Since this statistical measurement helps in the assessment of fidelity and image quality. The results showed that our approach can be applied of Image types of color spaces for biomedical images.

  9. Multimodality imaging techniques.

    Science.gov (United States)

    Martí-Bonmatí, Luis; Sopena, Ramón; Bartumeus, Paula; Sopena, Pablo

    2010-01-01

    In multimodality imaging, the need to combine morphofunctional information can be approached by either acquiring images at different times (asynchronous), and fused them through digital image manipulation techniques or simultaneously acquiring images (synchronous) and merging them automatically. The asynchronous post-processing solution presents various constraints, mainly conditioned by the different positioning of the patient in the two scans acquired at different times in separated machines. The best solution to achieve consistency in time and space is obtained by the synchronous image acquisition. There are many multimodal technologies in molecular imaging. In this review we will focus on those multimodality image techniques more commonly used in the field of diagnostic imaging (SPECT-CT, PET-CT) and new developments (as PET-MR). The technological innovations and development of new tracers and smart probes are the main key points that will condition multimodality image and diagnostic imaging professionals' future. Although SPECT-CT and PET-CT are standard in most clinical scenarios, MR imaging has some advantages, providing excellent soft-tissue contrast and multidimensional functional, structural and morphological information. The next frontier is to develop efficient detectors and electronics systems capable of detecting two modality signals at the same time. Not only PET-MR but also MR-US or optic-PET will be introduced in clinical scenarios. Even more, MR diffusion-weighted, pharmacokinetic imaging, spectroscopy or functional BOLD imaging will merge with PET tracers to further increase molecular imaging as a relevant medical discipline. Multimodality imaging techniques will play a leading role in relevant clinical applications. The development of new diagnostic imaging research areas, mainly in the field of oncology, cardiology and neuropsychiatry, will impact the way medicine is performed today. Both clinical and experimental multimodality studies, in

  10. Portable Imaging Polarimeter and Imaging Experiments; TOPICAL

    International Nuclear Information System (INIS)

    PHIPPS, GARY S.; KEMME, SHANALYN A.; SWEATT, WILLIAM C.; DESCOUR, M.R.; GARCIA, J.P.; DERENIAK, E.L.

    1999-01-01

    Polarimetry is the method of recording the state of polarization of light. Imaging polarimetry extends this method to recording the spatially resolved state of polarization within a scene. Imaging-polarimetry data have the potential to improve the detection of manmade objects in natural backgrounds. We have constructed a midwave infrared complete imaging polarimeter consisting of a fixed wire-grid polarizer and rotating form-birefringent retarder. The retardance and the orientation angles of the retarder were optimized to minimize the sensitivity of the instrument to noise in the measurements. The optimal retardance was found to be 132(degree) rather than the typical 90(degree). The complete imaging polarimeter utilized a liquid-nitrogen cooled PtSi camera. The fixed wire-grid polarizer was located at the cold stop inside the camera dewar. The complete imaging polarimeter was operated in the 4.42-5(micro)m spectral range. A series of imaging experiments was performed using as targets a surface of water, an automobile, and an aircraft. Further analysis of the polarization measurements revealed that in all three cases the magnitude of circular polarization was comparable to the noise in the calculated Stokes-vector components

  11. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  12. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  13. Detection of unstable angina by /sup 99m/technetium pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Abdulla, A.M.; Canedo, M.I.; Cortez, B.C.; McGinnis, K.D.; Wilhelm, S.K.

    1976-01-01

    /sup 99m/Technetium stannous pyrophosphate has been shown to accumulate in acutely infarcted myocardium. To determine if the isotope is also taken up by severely ischemic, but not necrotic myocardium, we performed myocardial scintigraphic studies in 17 patients with chest pains. Seven of the patients satisfied conventional clinical, electrocardiographic, and laboratory criteria for the diagnosis of unstable angina and showed no electrocardiographic or enzymatic evidence of myocardial necrosis. Five of these seven patients with unstable angina demonstrated abnormal localized patterns, and one showed a borderline picture. Myocardial scintiscans were normal in all of a control group of ten patients with stable angina. Thus, scanning with /sup 99m/technetium stannous pyrophosphate is shown to be of value in the objective demonstration of myocardial abnormality in unstable angina

  14. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murphy, W.A.

    1988-01-01

    After only a few years, MR imaging has proved to be an important method for imaging disorders of the musculoskeletal tissues. The images are characterized by great inherent contrast, excellent spatial resolution, and exquisite anatomic display - major reasons why MR imaging compares favorably with other imaging methods, such as radionuclide bone scanning and CT. MR imaging is particularly sensitive to bone marrow alterations and is very effective for detection and characterization of a wide variety of soft tissue conditions. Advances in surface coil technology will increase the usefulness of MR imaging in the evaluation of articular disease. In addition, chemical shift imaging and spectroscopy will add physiologic information to the anatomic features demonstrated by proton imaging

  15. Optoelectronic imaging of speckle using image processing method

    Science.gov (United States)

    Wang, Jinjiang; Wang, Pengfei

    2018-01-01

    A detailed image processing of laser speckle interferometry is proposed as an example for the course of postgraduate student. Several image processing methods were used together for dealing with optoelectronic imaging system, such as the partial differential equations (PDEs) are used to reduce the effect of noise, the thresholding segmentation also based on heat equation with PDEs, the central line is extracted based on image skeleton, and the branch is removed automatically, the phase level is calculated by spline interpolation method, and the fringe phase can be unwrapped. Finally, the imaging processing method was used to automatically measure the bubble in rubber with negative pressure which could be used in the tire detection.

  16. Review methods for image segmentation from computed tomography images

    International Nuclear Information System (INIS)

    Mamat, Nurwahidah; Rahman, Wan Eny Zarina Wan Abdul; Soh, Shaharuddin Cik; Mahmud, Rozi

    2014-01-01

    Image segmentation is a challenging process in order to get the accuracy of segmentation, automation and robustness especially in medical images. There exist many segmentation methods that can be implemented to medical images but not all methods are suitable. For the medical purposes, the aims of image segmentation are to study the anatomical structure, identify the region of interest, measure tissue volume to measure growth of tumor and help in treatment planning prior to radiation therapy. In this paper, we present a review method for segmentation purposes using Computed Tomography (CT) images. CT images has their own characteristics that affect the ability to visualize anatomic structures and pathologic features such as blurring of the image and visual noise. The details about the methods, the goodness and the problem incurred in the methods will be defined and explained. It is necessary to know the suitable segmentation method in order to get accurate segmentation. This paper can be a guide to researcher to choose the suitable segmentation method especially in segmenting the images from CT scan

  17. Electrocardiographic gating of list mode data with a positron emission tomography system that utilizes wobbling motion to achieve uniform sampling

    International Nuclear Information System (INIS)

    Gaeta, J.M.; Yerian, K.A.; Mullani, N.A.

    1986-01-01

    An interactive software package has been developed for gating of list mode data acquired with PET. The package supports: histogram displays (ie. for determining an acceptable beat interval length window), automatic rejection of beats outside the window, forward or backward gating capabilities, capability of specifying the position of the gating interval, and of the time interval within the list mode study to be reformatted. The interaction of PET wobble motion frequency and heart beat frequency may result in image non-uniformities (ringing artifacts), due to incomplete wobble sampling. Therefore, the reconstruction software incorporates a very simple scheme for correcting for the amount of time spent at each wobble position and allowing for the decay of short lived isotopes such as Rubidium-82 (Rb-82). Rb-82 myocardial uptake images free of non-uniformity artifacts and quantitatively accurate have been reconstructed for 10 different dog studies, and 8 patient studies. Multi-slice frames at discrete portions of the heart cycle (i.e. End Diastole) and multi-gated sequences for cine display have been produced

  18. First Human Experience with Directly Image-able Iodinated Embolization Microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P. [National Institutes of Health, Center for Interventional Oncology (United States); Lewis, Andrew L.; Willis, Sean; Macfarlane, Chelsea [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Anderson, Victoria [National Institutes of Health, Center for Interventional Oncology (United States); Bom, Imramsjah MJ van der [Clinical Science IGT Systems North & Latin America, Philips, Philips, Image Guided Interventions (United States); Radaelli, Alessandro [Image-Guided Therapy Systems, Philips, Philips, Image Guided Interventions (Netherlands); Dreher, Matthew R. [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Sharma, Karun V. [Children’s National Medical Center (United States); Negussie, Ayele; Mikhail, Andrew S. [National Institutes of Health, Center for Interventional Oncology (United States); Geschwind, Jean-Francois H. [Department of Radiology and Biomedical Imaging (United States); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology (United States)

    2016-08-15

    PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

  19. Application of image editing software for forensic detection of image ...

    African Journals Online (AJOL)

    Application of image editing software for forensic detection of image. ... The image editing software's available today is apt for creating visually compelling and sophisticated fake images, ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  20. BMC ecology image competition 2017: the winning images.

    Science.gov (United States)

    Foote, Christopher; Darimont, Chris T; Baguette, Michel; Blanchet, Simon; Jacobus, Luke M; Mazzi, Dominique; Settele, Josef

    2017-08-18

    For the fifth year, BMC Ecology is proud to present the winning images from our annual image competition. The 2017 edition received entries by talented shutterbug-ecologists from across the world, showcasing research that is increasing our understanding of ecosystems worldwide and the beauty and diversity of life on our planet. In this editorial we showcase the winning images, as chosen by our Editorial Board and guest judge Chris Darimont, as well as our selection of highly commended images. Enjoy!

  1. Microscopic validation of whole mouse micro-metastatic tumor imaging agents using cryo-imaging and sliding organ image registration

    OpenAIRE

    Liu, Yiqiao; Zhou, Bo; Qutaish, Mohammed; Wilson, David L.

    2016-01-01

    We created a metastasis imaging, analysis platform consisting of software and multi-spectral cryo-imaging system suitable for evaluating emerging imaging agents targeting micro-metastatic tumor. We analyzed CREKA-Gd in MRI, followed by cryo-imaging which repeatedly sectioned and tiled microscope images of the tissue block face, providing anatomical bright field and molecular fluorescence, enabling 3D microscopic imaging of the entire mouse with single metastatic cell sensitivity. To register ...

  2. Data imaging

    International Nuclear Information System (INIS)

    Pepy, G.

    1999-01-01

    After an introduction about data imaging in general, the principles of imaging data collected via neutron scattering experiments are presented. Some computer programs designed for data imaging purposes are reviewed. (K.A.)

  3. Cerenkov imaging.

    Science.gov (United States)

    Das, Sudeep; Thorek, Daniel L J; Grimm, Jan

    2014-01-01

    Cerenkov luminescence (CL) has been used recently in a plethora of medical applications like imaging and therapy with clinically relevant medical isotopes. The range of medical isotopes used is fairly large and expanding. The generation of in vivo light is useful since it circumvents depth limitations for excitation light. Cerenkov luminescence imaging (CLI) is much cheaper in terms of infrastructure than positron emission tomography (PET) and is particularly useful for imaging of superficial structures. Imaging can basically be done using a sensitive camera optimized for low-light conditions, and it has a better resolution than any other nuclear imaging modality. CLI has been shown to effectively diagnose disease with regularly used PET isotope ((18)F-FDG) in clinical setting. Cerenkov luminescence tomography, Cerenkov luminescence endoscopy, and intraoperative Cerenkov imaging have also been explored with positive conclusions expanding the current range of applications. Cerenkov has also been used to improve PET imaging resolution since the source of both is the radioisotope being used. Smart imaging agents have been designed based on modulation of the Cerenkov signal using small molecules and nanoparticles giving better insight of the tumor biology. © 2014 Elsevier Inc. All rights reserved.

  4. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    Science.gov (United States)

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  5. Distance between images

    Science.gov (United States)

    Gualtieri, J. A.; Le Moigne, J.; Packer, C. V.

    1992-01-01

    Comparing two binary images and assigning a quantitative measure to this comparison finds its purpose in such tasks as image recognition, image compression, and image browsing. This quantitative measurement may be computed by utilizing the Hausdorff distance of the images represented as two-dimensional point sets. In this paper, we review two algorithms that have been proposed to compute this distance, and we present a parallel implementation of one of them on the MasPar parallel processor. We study their complexity and the results obtained by these algorithms for two different types of images: a set of displaced pairs of images of Gaussian densities, and a comparison of a Canny edge image with several edge images from a hierarchical region growing code.

  6. Radiological Image Compression

    Science.gov (United States)

    Lo, Shih-Chung Benedict

    The movement toward digital images in radiology presents the problem of how to conveniently and economically store, retrieve, and transmit the volume of digital images. Basic research into image data compression is necessary in order to move from a film-based department to an efficient digital -based department. Digital data compression technology consists of two types of compression technique: error-free and irreversible. Error -free image compression is desired; however, present techniques can only achieve compression ratio of from 1.5:1 to 3:1, depending upon the image characteristics. Irreversible image compression can achieve a much higher compression ratio; however, the image reconstructed from the compressed data shows some difference from the original image. This dissertation studies both error-free and irreversible image compression techniques. In particular, some modified error-free techniques have been tested and the recommended strategies for various radiological images are discussed. A full-frame bit-allocation irreversible compression technique has been derived. A total of 76 images which include CT head and body, and radiographs digitized to 2048 x 2048, 1024 x 1024, and 512 x 512 have been used to test this algorithm. The normalized mean -square-error (NMSE) on the difference image, defined as the difference between the original and the reconstructed image from a given compression ratio, is used as a global measurement on the quality of the reconstructed image. The NMSE's of total of 380 reconstructed and 380 difference images are measured and the results tabulated. Three complex compression methods are also suggested to compress images with special characteristics. Finally, various parameters which would effect the quality of the reconstructed images are discussed. A proposed hardware compression module is given in the last chapter.

  7. Acoustical holographic Siamese image technique for imaging radial cracks in reactor piping

    International Nuclear Information System (INIS)

    Collins, H.D.; Gribble, R.P.

    1985-04-01

    This paper describes a unique technique (i.e., ''Siamese imaging'') for imaging quasi-vertical defects in reactor pipe weldments. The Siamese image is a bi-symmetrical view of the inner surface defect. Image construction geometry consists of two probes (i.e., source/receiver) operating either from opposite sides or the same side of the defect to be imaged. As the probes are scanned across a lower surface connected defect, they encounter two images - first the normal upright image and then the inverted image. The final integrated image consists of two images connected along their baselines, thus we call it a ''Siamese image.'' The experimental imaging results on simulated and natural cracks in reactor piping weldments graphically illustrate this unique technique. Excellent images of mechanical fatique and thermal cracks were obtained on ferritic and austenitic piping

  8. ImagingSIMS

    Energy Technology Data Exchange (ETDEWEB)

    2017-11-06

    ImagingSIMS is an open source application for loading, processing, manipulating and visualizing secondary ion mass spectrometry (SIMS) data. At PNNL, a separate branch has been further developed to incorporate application specific features for dynamic SIMS data sets. These include loading CAMECA IMS-1280, NanoSIMS and modified IMS-4f raw data, creating isotopic ratio images and stitching together images from adjacent interrogation regions. In addition to other modifications of the parent open source version, this version is equipped with a point-by-point image registration tool to assist with streamlining the image fusion process.

  9. Characteristics of image converters and image intensifiers

    International Nuclear Information System (INIS)

    Gurvich, A.M.; Shamanov, A.A.; Rozenberg, A.M.; Fajnberg, V.S.; Kavtorova, V.P.; Salyuk, L.V.; Yakovleva, F.B.

    1978-01-01

    The characteristics of image converters and image intensifiers, which determine the range of the X-radiation dose rates used and the image quality, are considered. The equations for calculating the requirements to be imposed on the separate intensifier elements from known parameters of other elements with an allowance for the nonlinearity of the television system and the role of fluctuation in the space distribution of X-radiation quanta are given

  10. Image registration method for medical image sequences

    Science.gov (United States)

    Gee, Timothy F.; Goddard, James S.

    2013-03-26

    Image registration of low contrast image sequences is provided. In one aspect, a desired region of an image is automatically segmented and only the desired region is registered. Active contours and adaptive thresholding of intensity or edge information may be used to segment the desired regions. A transform function is defined to register the segmented region, and sub-pixel information may be determined using one or more interpolation methods.

  11. Annotating images by mining image search results.

    Science.gov (United States)

    Wang, Xin-Jing; Zhang, Lei; Li, Xirong; Ma, Wei-Ying

    2008-11-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search results. Some 2.4 million images with their surrounding text are collected from a few photo forums to support this approach. The entire process is formulated in a divide-and-conquer framework where a query keyword is provided along with the uncaptioned image to improve both the effectiveness and efficiency. This is helpful when the collected data set is not dense everywhere. In this sense, our approach contains three steps: 1) the search process to discover visually and semantically similar search results, 2) the mining process to identify salient terms from textual descriptions of the search results, and 3) the annotation rejection process to filter out noisy terms yielded by Step 2. To ensure real-time annotation, two key techniques are leveraged-one is to map the high-dimensional image visual features into hash codes, the other is to implement it as a distributed system, of which the search and mining processes are provided as Web services. As a typical result, the entire process finishes in less than 1 second. Since no training data set is required, our approach enables annotating with unlimited vocabulary and is highly scalable and robust to outliers. Experimental results on both real Web images and a benchmark image data set show the effectiveness and efficiency of the proposed algorithm. It is also worth noting that, although the entire approach is illustrated within the divide-and conquer framework, a query keyword is not crucial to our current implementation. We provide experimental results to prove this.

  12. Image, Image, Image

    Science.gov (United States)

    Howell, Robert T.

    2004-01-01

    With all the talk today about accountability, budget cuts, and the closing of programs in public education, teachers cannot overlook the importance of image in the field of industrial technology. It is very easy for administrators to cut ITE (industrial technology education) programs to save school money--money they might shift to teaching the…

  13. Robust image registration for multiple exposure high dynamic range image synthesis

    Science.gov (United States)

    Yao, Susu

    2011-03-01

    Image registration is an important preprocessing technique in high dynamic range (HDR) image synthesis. This paper proposed a robust image registration method for aligning a group of low dynamic range images (LDR) that are captured with different exposure times. Illumination change and photometric distortion between two images would result in inaccurate registration. We propose to transform intensity image data into phase congruency to eliminate the effect of the changes in image brightness and use phase cross correlation in the Fourier transform domain to perform image registration. Considering the presence of non-overlapped regions due to photometric distortion, evolutionary programming is applied to search for the accurate translation parameters so that the accuracy of registration is able to be achieved at a hundredth of a pixel level. The proposed algorithm works well for under and over-exposed image registration. It has been applied to align LDR images for synthesizing high quality HDR images..

  14. No-reference image quality assessment for horizontal-path imaging scenarios

    Science.gov (United States)

    Rios, Carlos; Gladysz, Szymon

    2013-05-01

    There exist several image-enhancement algorithms and tasks associated with imaging through turbulence that depend on defining the quality of an image. Examples include: "lucky imaging", choosing the width of the inverse filter for image reconstruction, or stopping iterative deconvolution. We collected a number of image quality metrics found in the literature. Particularly interesting are the blind, "no-reference" metrics. We discuss ways of evaluating the usefulness of these metrics, even when a fully objective comparison is impossible because of the lack of a reference image. Metrics are tested on simulated and real data. Field data comes from experiments performed by the NATO SET 165 research group over a 7 km distance in Dayton, Ohio.

  15. Imaging techniques and investigation protocols in pediatric emergency imaging

    International Nuclear Information System (INIS)

    Scharitzer, M.; Hoermann, M.; Puig, S.; Prokop, M.

    2002-01-01

    Paediatric emergencies demand a quick and efficient radiological investigation with special attention to specific adjustments related to patient age and radiation protection. Imaging modalities are improving rapidly and enable to diagnose childhood diseases and injuries more quickly, accurately and safely. This article provides an overview of imaging techniques adjusted to the age of the child and an overview of imaging strategies of common paediatric emergencies. Optimising the imaging parameters (digital radiography, different screen-film systems, exposure specifications) allows for substantial reduction of radiation dose. Spiral- and multislice-CT reduce scan time and enable a considerable reduction of radiation exposure if scanning parameters (pitch setting, tube current) are properly adjusted. MRI is still mainly used for neurological or spinal emergencies despite the advent of fast imaging sequences. The radiologist's task is to select an appropriate imaging strategy according to expected differential diagnosis and to adjust the imaging techniques to the individual patient. (orig.) [de

  16. Prior image constrained image reconstruction in emerging computed tomography applications

    Science.gov (United States)

    Brunner, Stephen T.

    Advances have been made in computed tomography (CT), especially in the past five years, by incorporating prior images into the image reconstruction process. In this dissertation, we investigate prior image constrained image reconstruction in three emerging CT applications: dual-energy CT, multi-energy photon-counting CT, and cone-beam CT in image-guided radiation therapy. First, we investigate the application of Prior Image Constrained Compressed Sensing (PICCS) in dual-energy CT, which has been called "one of the hottest research areas in CT." Phantom and animal studies are conducted using a state-of-the-art 64-slice GE Discovery 750 HD CT scanner to investigate the extent to which PICCS can enable radiation dose reduction in material density and virtual monochromatic imaging. Second, we extend the application of PICCS from dual-energy CT to multi-energy photon-counting CT, which has been called "one of the 12 topics in CT to be critical in the next decade." Numerical simulations are conducted to generate multiple energy bin images for a photon-counting CT acquisition and to investigate the extent to which PICCS can enable radiation dose efficiency improvement. Third, we investigate the performance of a newly proposed prior image constrained scatter correction technique to correct scatter-induced shading artifacts in cone-beam CT, which, when used in image-guided radiation therapy procedures, can assist in patient localization, and potentially, dose verification and adaptive radiation therapy. Phantom studies are conducted using a Varian 2100 EX system with an on-board imager to investigate the extent to which the prior image constrained scatter correction technique can mitigate scatter-induced shading artifacts in cone-beam CT. Results show that these prior image constrained image reconstruction techniques can reduce radiation dose in dual-energy CT by 50% in phantom and animal studies in material density and virtual monochromatic imaging, can lead to radiation

  17. Optimization of the alpha image reconstruction. An iterative CT-image reconstruction with well-defined image quality metrics

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Sergej; Sawall, Stefan; Knaup, Michael; Kachelriess, Marc [German Cancer Research Center, Heidelberg (Germany).

    2017-10-01

    Optimization of the AIR-algorithm for improved convergence and performance. TThe AIR method is an iterative algorithm for CT image reconstruction. As a result of its linearity with respect to the basis images, the AIR algorithm possesses well defined, regular image quality metrics, e.g. point spread function (PSF) or modulation transfer function (MTF), unlike other iterative reconstruction algorithms. The AIR algorithm computes weighting images α to blend between a set of basis images that preferably have mutually exclusive properties, e.g. high spatial resolution or low noise. The optimized algorithm uses an approach that alternates between the optimization of rawdata fidelity using an OSSART like update and regularization using gradient descent, as opposed to the initially proposed AIR using a straightforward gradient descent implementation. A regularization strength for a given task is chosen by formulating a requirement for the noise reduction and checking whether it is fulfilled for different regularization strengths, while monitoring the spatial resolution using the voxel-wise defined modulation transfer function for the AIR image. The optimized algorithm computes similar images in a shorter time compared to the initial gradient descent implementation of AIR. The result can be influenced by multiple parameters that can be narrowed down to a relatively simple framework to compute high quality images. The AIR images, for instance, can have at least a 50% lower noise level compared to the sharpest basis image, while the spatial resolution is mostly maintained. The optimization improves performance by a factor of 6, while maintaining image quality. Furthermore, it was demonstrated that the spatial resolution for AIR can be determined using regular image quality metrics, given smooth weighting images. This is not possible for other iterative reconstructions as a result of their non linearity. A simple set of parameters for the algorithm is discussed that provides

  18. Optimization of the alpha image reconstruction. An iterative CT-image reconstruction with well-defined image quality metrics

    International Nuclear Information System (INIS)

    Lebedev, Sergej; Sawall, Stefan; Knaup, Michael; Kachelriess, Marc

    2017-01-01

    Optimization of the AIR-algorithm for improved convergence and performance. TThe AIR method is an iterative algorithm for CT image reconstruction. As a result of its linearity with respect to the basis images, the AIR algorithm possesses well defined, regular image quality metrics, e.g. point spread function (PSF) or modulation transfer function (MTF), unlike other iterative reconstruction algorithms. The AIR algorithm computes weighting images α to blend between a set of basis images that preferably have mutually exclusive properties, e.g. high spatial resolution or low noise. The optimized algorithm uses an approach that alternates between the optimization of rawdata fidelity using an OSSART like update and regularization using gradient descent, as opposed to the initially proposed AIR using a straightforward gradient descent implementation. A regularization strength for a given task is chosen by formulating a requirement for the noise reduction and checking whether it is fulfilled for different regularization strengths, while monitoring the spatial resolution using the voxel-wise defined modulation transfer function for the AIR image. The optimized algorithm computes similar images in a shorter time compared to the initial gradient descent implementation of AIR. The result can be influenced by multiple parameters that can be narrowed down to a relatively simple framework to compute high quality images. The AIR images, for instance, can have at least a 50% lower noise level compared to the sharpest basis image, while the spatial resolution is mostly maintained. The optimization improves performance by a factor of 6, while maintaining image quality. Furthermore, it was demonstrated that the spatial resolution for AIR can be determined using regular image quality metrics, given smooth weighting images. This is not possible for other iterative reconstructions as a result of their non linearity. A simple set of parameters for the algorithm is discussed that provides

  19. Image splitting and remapping method for radiological image compression

    Science.gov (United States)

    Lo, Shih-Chung B.; Shen, Ellen L.; Mun, Seong K.

    1990-07-01

    A new decomposition method using image splitting and gray-level remapping has been proposed for image compression, particularly for images with high contrast resolution. The effects of this method are especially evident in our radiological image compression study. In our experiments, we tested the impact of this decomposition method on image compression by employing it with two coding techniques on a set of clinically used CT images and several laser film digitized chest radiographs. One of the compression techniques used was full-frame bit-allocation in the discrete cosine transform domain, which has been proven to be an effective technique for radiological image compression. The other compression technique used was vector quantization with pruned tree-structured encoding, which through recent research has also been found to produce a low mean-square-error and a high compression ratio. The parameters we used in this study were mean-square-error and the bit rate required for the compressed file. In addition to these parameters, the difference between the original and reconstructed images will be presented so that the specific artifacts generated by both techniques can be discerned by visual perception.

  20. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  1. Image forming apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    An image H(x, y) for displaying a target image G(x, y) is displayed on a liquid-crystal display panel and illumination light from an illumination light source is made to pass therethrough to form an image on a PALSLM. Read light hv is radiated to the PALSLM and a phase-modulated light image alpha...... (x, y) read out of the PALSLM is subjected to Fourier transform by a lens. A phase contrast filter gives a predetermined phase shift to only the zero-order light component of Fourier light image alpha f(x, y). The phase-shifted light image is subjected to inverse Fourier transform by a lens...... to project an output image O(x, y) to an output plane. A light image O'(x, y) branched by a beam sampler is picked up by a pickup device and an evaluation value calculating unit evaluates conformity between the image O(x, y) and the image G(x, y).; A control unit performs feedback control of optical...

  2. A hierarchical SVG image abstraction layer for medical imaging

    Science.gov (United States)

    Kim, Edward; Huang, Xiaolei; Tan, Gang; Long, L. Rodney; Antani, Sameer

    2010-03-01

    As medical imaging rapidly expands, there is an increasing need to structure and organize image data for efficient analysis, storage and retrieval. In response, a large fraction of research in the areas of content-based image retrieval (CBIR) and picture archiving and communication systems (PACS) has focused on structuring information to bridge the "semantic gap", a disparity between machine and human image understanding. An additional consideration in medical images is the organization and integration of clinical diagnostic information. As a step towards bridging the semantic gap, we design and implement a hierarchical image abstraction layer using an XML based language, Scalable Vector Graphics (SVG). Our method encodes features from the raw image and clinical information into an extensible "layer" that can be stored in a SVG document and efficiently searched. Any feature extracted from the raw image including, color, texture, orientation, size, neighbor information, etc., can be combined in our abstraction with high level descriptions or classifications. And our representation can natively characterize an image in a hierarchical tree structure to support multiple levels of segmentation. Furthermore, being a world wide web consortium (W3C) standard, SVG is able to be displayed by most web browsers, interacted with by ECMAScript (standardized scripting language, e.g. JavaScript, JScript), and indexed and retrieved by XML databases and XQuery. Using these open source technologies enables straightforward integration into existing systems. From our results, we show that the flexibility and extensibility of our abstraction facilitates effective storage and retrieval of medical images.

  3. Objective analysis of image quality of video image capture systems

    Science.gov (United States)

    Rowberg, Alan H.

    1990-07-01

    As Picture Archiving and Communication System (PACS) technology has matured, video image capture has become a common way of capturing digital images from many modalities. While digital interfaces, such as those which use the ACR/NEMA standard, will become more common in the future, and are preferred because of the accuracy of image transfer, video image capture will be the dominant method in the short term, and may continue to be used for some time because of the low cost and high speed often associated with such devices. Currently, virtually all installed systems use methods of digitizing the video signal that is produced for display on the scanner viewing console itself. A series of digital test images have been developed for display on either a GE CT9800 or a GE Signa MRI scanner. These images have been captured with each of five commercially available image capture systems, and the resultant images digitally transferred on floppy disk to a PC1286 computer containing Optimast' image analysis software. Here the images can be displayed in a comparative manner for visual evaluation, in addition to being analyzed statistically. Each of the images have been designed to support certain tests, including noise, accuracy, linearity, gray scale range, stability, slew rate, and pixel alignment. These image capture systems vary widely in these characteristics, in addition to the presence or absence of other artifacts, such as shading and moire pattern. Other accessories such as video distribution amplifiers and noise filters can also add or modify artifacts seen in the captured images, often giving unusual results. Each image is described, together with the tests which were performed using them. One image contains alternating black and white lines, each one pixel wide, after equilibration strips ten pixels wide. While some systems have a slew rate fast enough to track this correctly, others blur it to an average shade of gray, and do not resolve the lines, or give

  4. Predicting Visible Image Degradation by Colour Image Difference Formulae

    Institute of Scientific and Technical Information of China (English)

    Eriko Bando; Jon Y. Hardeberg; David Connah; Ivar Farup

    2004-01-01

    It carried out a CRT monitor based psychophysical experiment to investigate the quality of three colour image difference metrics, the CIEAE ab equation, the iCAM and the S-CIELAB metrics. Six original images were reproduced through six gamut mapping algorithms for the observer experiment. The result indicates that the colour image difference calculated by each metric does not directly relate to perceived image difference.

  5. Cardiac evaluation in children with Prader-Willi syndrome.

    NARCIS (Netherlands)

    Marcus, K.A.; Alfen-van der Velden, J. van; Otten, B.J.; Weijers, G.; Yntema, H.G.; Korte, C.L. de; Kapusta, L.

    2012-01-01

    AIM: To assess cardiac anatomy and myocardial systolic function in children with Prader-Willi syndrome (PWS). METHODS: Physical examination, electrocardiographic (ECG) recordings and transthoracic echocardiograms including two-dimensional speckle tracking echocardiography (2DSTE) were performed and

  6. Changes in subclinical organ damage vs. in Framingham risk score for assessing cardiovascular risk reduction during continued antihypertensive treatment: a LIFE substudy

    DEFF Research Database (Denmark)

    Olsen, Michael H; Wachtell, Kristian; Ibsen, Hans

    2011-01-01

    To investigate whether in-treatment measurements of subclinical organ damage (SOD) assessed by elevated urine albumin/creatinine ratio (UACR) or electrocardiographic left ventricular hypertrophy improved the prediction of the composite cardiovascular endpoint of cardiovascular death, nonfatal...

  7. A New Perspective for Identifying Potential Cardiac Sensitizers

    National Research Council Canada - National Science Library

    Smith, E

    1999-01-01

    .... The dog and the swine were used as surrogates for the human. Physiologic and electrocardiographic measurements were taken during the control period and after each dose of ouabain, a digitalis glycoside known to provoke ventricular arrhythmia...

  8. An application of image processing techniques in computed tomography image analysis

    DEFF Research Database (Denmark)

    McEvoy, Fintan

    2007-01-01

    number of animals and image slices, automation of the process was desirable. The open-source and free image analysis program ImageJ was used. A macro procedure was created that provided the required functionality. The macro performs a number of basic image processing procedures. These include an initial...... process designed to remove the scanning table from the image and to center the animal in the image. This is followed by placement of a vertical line segment from the mid point of the upper border of the image to the image center. Measurements are made between automatically detected outer and inner...... boundaries of subcutaneous adipose tissue along this line segment. This process was repeated as the image was rotated (with the line position remaining unchanged) so that measurements around the complete circumference were obtained. Additionally, an image was created showing all detected boundary points so...

  9. Acoustical Imaging

    CERN Document Server

    Litniewski, Jerzy; Kujawska, Tamara; 31st International Symposium on Acoustical Imaging

    2012-01-01

    The International Symposium on Acoustical Imaging is a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. This interdisciplinary Symposium has been taking place continuously since 1968. In the course of the years the proceedings volumes in the Acoustical Imaging Series have become a reference for cutting-edge research in the field. In 2011 the 31st International Symposium on Acoustical Imaging was held in Warsaw, Poland, April 10-13. Offering both a broad perspective on the state-of-the-art as well as  in-depth research contributions by the specialists in the field, this Volume 31 in the Series contains an excellent collection of papers in six major categories: Biological and Medical Imaging Physics and Mathematics of Acoustical Imaging Acoustic Microscopy Transducers and Arrays Nondestructive Evaluation and Industrial Applications Underwater Imaging

  10. Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images.

    Science.gov (United States)

    Sakabe, Daisuke; Funama, Yoshinori; Taguchi, Katsuyuki; Nakaura, Takeshi; Utsunomiya, Daisuke; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Yamashita, Yasuyuki

    2018-05-01

    To investigate the image quality characteristics for virtual monoenergetic images compared with conventional tube-voltage image with dual-layer spectral CT (DLCT). Helical scans were performed using a first-generation DLCT scanner, two different sizes of acrylic cylindrical phantoms, and a Catphan phantom. Three different iodine concentrations were inserted into the phantom center. The single-tube voltage for obtaining virtual monoenergetic images was set to 120 or 140 kVp. Conventional 120- and 140-kVp images and virtual monoenergetic images (40-200-keV images) were reconstructed from slice thicknesses of 1.0 mm. The CT number and image noise were measured for each iodine concentration and water on the 120-kVp images and virtual monoenergetic images. The noise power spectrum (NPS) was also calculated. The iodine CT numbers for the iodinated enhancing materials were similar regardless of phantom size and acquisition method. Compared with the iodine CT numbers of the conventional 120-kVp images, those for the monoenergetic 40-, 50-, and 60-keV images increased by approximately 3.0-, 1.9-, and 1.3-fold, respectively. The image noise values for each virtual monoenergetic image were similar (for example, 24.6 HU at 40 keV and 23.3 HU at 200 keV obtained at 120 kVp and 30-cm phantom size). The NPS curves of the 70-keV and 120-kVp images for a 1.0-mm slice thickness over the entire frequency range were similar. Virtual monoenergetic images represent stable image noise over the entire energy spectrum and improved the contrast-to-noise ratio than conventional tube voltage using the dual-layer spectral detector CT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  11. Tomographic imaging

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    Tomography is used to image anatomy of organs as in the case of CT and MRI or image body functions as in the case of SPECT and PET. The theory of reconstruction applies equally well to CT, SPECT and PET with a minor differences. The main difference between SPECT and PET is that SPECT images single photon emitters (radionuclides) which emit normal gamma rays (like Tc-99m), whereas PET images positron emitting radionuclides such as O 15 or F 18 . The word tomography means drawing of the body. Every tomography results in an image of the inside of the body and is represented as a slice. (author)

  12. Image Guidance

    Science.gov (United States)

    Guidance that explains the process for getting images approved in One EPA Web microsites and resource directories. includes an appendix that shows examples of what makes some images better than others, how some images convey meaning more than others

  13. A NEW IMAGE REGISTRATION METHOD FOR GREY IMAGES

    Institute of Scientific and Technical Information of China (English)

    Nie Xuan; Zhao Rongchun; Jiang Zetao

    2004-01-01

    The proposed algorithm relies on a group of new formulas for calculating tangent slope so as to address angle feature of edge curves of image. It can utilize tangent angle features to estimate automatically and fully the rotation parameters of geometric transform and enable rough matching of images with huge rotation difference. After angle compensation, it can search for matching point sets by correlation criterion, then calculate parameters of affine transform, enable higher-precision emendation of rotation and transferring. Finally, it fulfills precise matching for images with relax-tense iteration method. Compared with the registration approach based on wavelet direction-angle features, the matching algorithm with tangent feature of image edge is more robust and realizes precise registration of various images. Furthermore, it is also helpful in graphics matching.

  14. A novel data processing technique for image reconstruction of penumbral imaging

    Science.gov (United States)

    Xie, Hongwei; Li, Hongyun; Xu, Zeping; Song, Guzhou; Zhang, Faqiang; Zhou, Lin

    2011-06-01

    CT image reconstruction technique was applied to the data processing of the penumbral imaging. Compared with other traditional processing techniques for penumbral coded pinhole image such as Wiener, Lucy-Richardson and blind technique, this approach is brand new. In this method, the coded aperture processing method was used for the first time independent to the point spread function of the image diagnostic system. In this way, the technical obstacles was overcome in the traditional coded pinhole image processing caused by the uncertainty of point spread function of the image diagnostic system. Then based on the theoretical study, the simulation of penumbral imaging and image reconstruction was carried out to provide fairly good results. While in the visible light experiment, the point source of light was used to irradiate a 5mm×5mm object after diffuse scattering and volume scattering. The penumbral imaging was made with aperture size of ~20mm. Finally, the CT image reconstruction technique was used for image reconstruction to provide a fairly good reconstruction result.

  15. Geometric correction of radiographic images using general purpose image processing program

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Cheong, Ji Seong; Lee, Sang Hoon

    1994-01-01

    The present study was undertaken to compare geometric corrected image by general-purpose image processing program for the Apple Macintosh II computer (NIH Image, Adobe Photoshop) with standardized image by individualized custom fabricated alignment instrument. Two non-standardized periapical films with XCP film holder only were taken at the lower molar portion of 19 volunteers. Two standardized periapical films with customized XCP film holder with impression material on the bite-block were taken for each person. Geometric correction was performed with Adobe Photoshop and NIH Image program. Specially, arbitrary image rotation function of 'Adobe Photoshop' and subtraction with transparency function of 'NIH Image' were utilized. The standard deviations of grey values of subtracted images were used to measure image similarity. Average standard deviation of grey values of subtracted images if standardized group was slightly lower than that of corrected group. However, the difference was found to be statistically insignificant (p>0.05). It is considered that we can use 'NIH Image' and 'Adobe Photoshop' program for correction of nonstandardized film, taken with XCP film holder at lower molar portion.

  16. Image Denoising And Segmentation Approchto Detect Tumor From BRAINMRI Images

    Directory of Open Access Journals (Sweden)

    Shanta Rangaswamy

    2018-04-01

    Full Text Available The detection of the Brain Tumor is a challenging problem, due to the structure of the Tumor cells in the brain. This project presents a systematic method that enhances the detection of brain tumor cells and to analyze functional structures by training and classification of the samples in SVM and tumor cell segmentation of the sample using DWT algorithm. From the input MRI Images collected, first noise is removed from MRI images by applying wiener filtering technique. In image enhancement phase, all the color components of MRI Images will be converted into gray scale image and make the edges clear in the image to get better identification and improvised quality of the image. In the segmentation phase, DWT on MRI Image to segment the grey-scale image is performed. During the post-processing, classification of tumor is performed by using SVM classifier. Wiener Filter, DWT, SVM Segmentation strategies were used to find and group the tumor position in the MRI filtered picture respectively. An essential perception in this work is that multi arrange approach utilizes various leveled classification strategy which supports execution altogether. This technique diminishes the computational complexity quality in time and memory. This classification strategy works accurately on all images and have achieved the accuracy of 93%.

  17. Image analysis and modeling in medical image computing. Recent developments and advances.

    Science.gov (United States)

    Handels, H; Deserno, T M; Meinzer, H-P; Tolxdorff, T

    2012-01-01

    Medical image computing is of growing importance in medical diagnostics and image-guided therapy. Nowadays, image analysis systems integrating advanced image computing methods are used in practice e.g. to extract quantitative image parameters or to support the surgeon during a navigated intervention. However, the grade of automation, accuracy, reproducibility and robustness of medical image computing methods has to be increased to meet the requirements in clinical routine. In the focus theme, recent developments and advances in the field of modeling and model-based image analysis are described. The introduction of models in the image analysis process enables improvements of image analysis algorithms in terms of automation, accuracy, reproducibility and robustness. Furthermore, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients. Selected contributions are assembled to present latest advances in the field. The authors were invited to present their recent work and results based on their outstanding contributions to the Conference on Medical Image Computing BVM 2011 held at the University of Lübeck, Germany. All manuscripts had to pass a comprehensive peer review. Modeling approaches and model-based image analysis methods showing new trends and perspectives in model-based medical image computing are described. Complex models are used in different medical applications and medical images like radiographic images, dual-energy CT images, MR images, diffusion tensor images as well as microscopic images are analyzed. The applications emphasize the high potential and the wide application range of these methods. The use of model-based image analysis methods can improve segmentation quality as well as the accuracy and reproducibility of quantitative image analysis. Furthermore, image-based models enable new insights and can lead to a deeper understanding of complex dynamic mechanisms in the human body

  18. Image Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Wendelberger, Laura Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-08

    In large datasets, it is time consuming or even impossible to pick out interesting images. Our proposed solution is to find statistics to quantify the information in each image and use those to identify and pick out images of interest.

  19. A generalized framework unifying image registration and respiratory motion models and incorporating image reconstruction, for partial image data or full images

    Science.gov (United States)

    McClelland, Jamie R.; Modat, Marc; Arridge, Simon; Grimes, Helen; D'Souza, Derek; Thomas, David; O' Connell, Dylan; Low, Daniel A.; Kaza, Evangelia; Collins, David J.; Leach, Martin O.; Hawkes, David J.

    2017-06-01

    Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization. This allows the use of ‘partial’ imaging data, such as individual slices, projections, or k-space data, where it would not be possible to determine the motion from an individual frame of data. Motion compensated image reconstruction can also be incorporated using an iterative approach, so that both the motion and a motion-free image can be estimated from the partial image data. The framework has been applied to real 4DCT, Cine CT, multi-slice CT, and multi-slice MR data, as well as simulated datasets from a computer phantom. This includes the use of a super-resolution reconstruction method for the multi-slice MR data. Good results were obtained for all datasets, including quantitative results for the 4DCT and phantom datasets where the ground truth motion was known or could be estimated.

  20. Compositional-prior-guided image reconstruction algorithm for multi-modality imaging

    Science.gov (United States)

    Fang, Qianqian; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.

    2010-01-01

    The development of effective multi-modality imaging methods typically requires an efficient information fusion model, particularly when combining structural images with a complementary imaging modality that provides functional information. We propose a composition-based image segmentation method for X-ray digital breast tomosynthesis (DBT) and a structural-prior-guided image reconstruction for a combined DBT and diffuse optical tomography (DOT) breast imaging system. Using the 3D DBT images from 31 clinically measured healthy breasts, we create an empirical relationship between the X-ray intensities for adipose and fibroglandular tissue. We use this relationship to then segment another 58 healthy breast DBT images from 29 subjects into compositional maps of different tissue types. For each breast, we build a weighted-graph in the compositional space and construct a regularization matrix to incorporate the structural priors into a finite-element-based DOT image reconstruction. Use of the compositional priors enables us to fuse tissue anatomy into optical images with less restriction than when using a binary segmentation. This allows us to recover the image contrast captured by DOT but not by DBT. We show that it is possible to fine-tune the strength of the structural priors by changing a single regularization parameter. By estimating the optical properties for adipose and fibroglandular tissue using the proposed algorithm, we found the results are comparable or superior to those estimated with expert-segmentations, but does not involve the time-consuming manual selection of regions-of-interest. PMID:21258460

  1. Imaging efficacy of a targeted imaging agent for fluorescence endoscopy

    Science.gov (United States)

    Healey, A. J.; Bendiksen, R.; Attramadal, T.; Bjerke, R.; Waagene, S.; Hvoslef, A. M.; Johannesen, E.

    2008-02-01

    Colorectal cancer is a major cause of cancer death. A significant unmet clinical need exists in the area of screening for earlier and more accurate diagnosis and treatment. We have identified a fluorescence imaging agent targeted to an early stage molecular marker for colorectal cancer. The agent is administered intravenously and imaged in a far red imaging channel as an adjunct to white light endoscopy. There is experimental evidence of preclinical proof of mechanism for the agent. In order to assess potential clinical efficacy, imaging was performed with a prototype fluorescence endoscope system designed to produce clinically relevant images. A clinical laparoscope system was modified for fluorescence imaging. The system was optimised for sensitivity. Images were recorded at settings matching those expected with a clinical endoscope implementation (at video frame rate operation). The animal model was comprised of a HCT-15 xenograft tumour expressing the target at concentration levels expected in early stage colorectal cancer. Tumours were grown subcutaneously. The imaging agent was administered intravenously at a dose of 50nmol/kg body weight. The animals were killed 2 hours post administration and prepared for imaging. A 3-4mm diameter, 1.6mm thick slice of viable tumour was placed over the opened colon and imaged with the laparoscope system. A receiver operator characteristic analysis was applied to imaging results. An area under the curve of 0.98 and a sensitivity of 87% [73, 96] and specificity of 100% [93, 100] were obtained.

  2. Microwave imaging

    CERN Document Server

    Pastorino, Matteo

    2010-01-01

    An introduction to the most relevant theoretical and algorithmic aspects of modern microwave imaging approaches Microwave imaging-a technique used in sensing a given scene by means of interrogating microwaves-has recently proven its usefulness in providing excellent diagnostic capabilities in several areas, including civil and industrial engineering, nondestructive testing and evaluation, geophysical prospecting, and biomedical engineering. Microwave Imaging offers comprehensive descriptions of the most important techniques so far proposed for short-range microwave imaging-in

  3. Initial patient imaging with an optimised radiotherapy beam for portal imaging

    International Nuclear Information System (INIS)

    Flampouri, Stella; McNair, Helen A.; Donovan, Ellen M.; Evans, Philip M.; Partridge, Mike; Verhaegen, Frank; Nutting, Christopher M.

    2005-01-01

    Background and purpose: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd 2 O 2 S/film detector, for patient imaging. Patients and methods: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6 mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. Results: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10 -2 Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. Conclusions: This pilot study of the new portal imaging system showed the image quality is significantly improved

  4. Imaging in hematology. Part 2: Computed tomography, magnetic resonance imaging and nuclear imaging

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    A dramatic increase of the role of imaging in diagnosis of blood diseases occurred with the development of computed tomography (CT) and magnetic resonance imaging (MRI). At present CT of the chest, abdomen, and pelvis is routinely employed in diagnostic and staging evaluation. The bone marrow may be imaged by one of several methods, including scintigraphy, CT and MRI. Nuclear imaging at diagnosis can clarify findings of uncertain significance on conventional staging and may be very useful in the setting of large masses to follow responses to therapy nad to evaluate the residual tumor in a large mass that has responded to treatment. Recent developments such as helical CT, single proton emission computed tomography (SPECT) and positron-emission tomography (PET) have continued to advance diagnosis and therapy

  5. Extracting flat-field images from scene-based image sequences using phase correlation

    Energy Technology Data Exchange (ETDEWEB)

    Caron, James N., E-mail: Caron@RSImd.com [Research Support Instruments, 4325-B Forbes Boulevard, Lanham, Maryland 20706 (United States); Montes, Marcos J. [Naval Research Laboratory, Code 7231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Obermark, Jerome L. [Naval Research Laboratory, Code 8231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States)

    2016-06-15

    Flat-field image processing is an essential step in producing high-quality and radiometrically calibrated images. Flat-fielding corrects for variations in the gain of focal plane array electronics and unequal illumination from the system optics. Typically, a flat-field image is captured by imaging a radiometrically uniform surface. The flat-field image is normalized and removed from the images. There are circumstances, such as with remote sensing, where a flat-field image cannot be acquired in this manner. For these cases, we developed a phase-correlation method that allows the extraction of an effective flat-field image from a sequence of scene-based displaced images. The method uses sub-pixel phase correlation image registration to align the sequence to estimate the static scene. The scene is removed from sequence producing a sequence of misaligned flat-field images. An average flat-field image is derived from the realigned flat-field sequence.

  6. Images and society (or Images, Society and its Decoding

    Directory of Open Access Journals (Sweden)

    Juan Soto Ramírez

    2012-11-01

    Full Text Available Common sense, the thinking of the people par excellence, asserts that: a picture is worth a thousand words. This is a big mistake. The images are not carriers of meanings. The images always go through three basic processes are: production, circulation and reception. These processes are always determined in the time and social space. They are always the result of multiple relationships (social, ideological, political, moral, religious, etc., established with them. Always there are so many elements beyond the image, which determines its meaning. The meaning of an image always depends on the relationships established with it in a historical time and space, socially and culturally determined. The images are never alone. To decrypt their meanings, you must first know the symbolic life of the societies in which they appear. Images do not have a single meaning because it depends on the historical and cultural geography which presents. The images always have a close relationship with the society they were born. The Muhammad cartoons not offend everyone equally.

  7. Pilot study of dynamic cine CT angiography for the evaluation of abdominal aortic aneurysms : Implications for endograft treatment

    NARCIS (Netherlands)

    Teutelink, A; Rutten, A; Muhs, BE; Olree, M; van Herwaarden, JA; de Vos, AM; Prokop, M; Moll, FL; Verhagen, HJM

    Purpose: To utilize 40-slice electrocardiographically (ECG)-gated cine computed tomographic angiography (CTA) to characterize normal aortic motion during the cardiac cycle at relevant anatomical landmarks in preoperative abdominal aortic aneurysm (AAA) patients. Methods: In 10 consecutive

  8. Computerised Analysis, Interpretation, Storage and Retrieval of ...

    African Journals Online (AJOL)

    1974-06-08

    Jun 8, 1974 ... research. This whole process is time-consuming for both tech- nicians and ... ECG directly from the patient, make an automatic graphic recording on ..... reasoned that the electrocardiographic interpretation is better done by a ...

  9. Image sequence analysis in nuclear medicine: (1) Parametric imaging using statistical modelling

    International Nuclear Information System (INIS)

    Liehn, J.C.; Hannequin, P.; Valeyre, J.

    1989-01-01

    This is a review of parametric imaging methods on Nuclear Medicine. A Parametric Image is an image in which each pixel value is a function of the value of the same pixel of an image sequence. The Local Model Method is the fitting of each pixel time activity curve by a model which parameter values form the Parametric Images. The Global Model Method is the modelling of the changes between two images. It is applied to image comparison. For both methods, the different models, the identification criterion, the optimization methods and the statistical properties of the images are discussed. The analysis of one or more Parametric Images is performed using 1D or 2D histograms. The statistically significant Parametric Images, (Images of significant Variances, Amplitudes and Differences) are also proposed [fr

  10. Cardiac and vascular imaging with snapshot FLASH MR imaging

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Norris, D.; Leibfritz, D.; Henrich, D.; Duhmke, E.

    1989-01-01

    Acceleration of fast low-angle-shot (FLASH) MR imaging to about 200 msec measuring time on dedicated MR systems is called snapshot FLASH MR imaging. It snaps real-time series of MR images of the MR relaxation and of physiologic motions with nearly absent motion and susceptibility artifacts. Results in animals (4.7T) and human volunteers (2.0T) show plain vascular and cardiac snapshot FLASH MR images obtained as single shot, triggered reconstructed motion, or real-time films. The reduction of artifacts and the high resolution (triggered, three-dimensional moving heart images are possible) result in favorable applications in myocardial and great vascular disease

  11. NMR imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.

    1983-01-01

    Since hydrogen is the most abundant element in all living organisms, proton NMR lends itself well as a method of investigation in biology and medicine. NMR imaging has some special advantages as a diagnostic tool: no ionizing radiation is used, it is noninvasive; it provides a safer means of imaging than the use of x-rays, gamma rays, positrons, or heavy ions. In contrast with ultrasound, the radiation penetrates the bony structures without attenuation. In additional to morphological information, NMR imaging provides additional diagnostic insights through relaxation parameters, which are not available from other imaging methods. In the decade since the first primitive NMR images were obtained, the quality of images now obtained approaches those from CT x-ray scanners. Prototype instruments are being constructed for clinical evaluation and the first whole-body scanners are beginning to appear on the market at costs comparable to CT scanners. Primary differences in equipment for conventional NMR and NMR imaging are the much larger aperture magnets that are required for the examination of human subjects and the addition of coils to generate field gradients and facilities for manipulating the gradients. Early results from clinical trials in many parts of the world are encouraging, and in a few years, the usefuleness of this modality of medical imaging to the medical profession in diagnosis and treatment of disease will be defined. 10 figures

  12. Progress on molecular imaging

    International Nuclear Information System (INIS)

    Chen Quan; Zhang Yongxue

    2011-01-01

    Molecular imaging is a new era of medical imaging,which can non-invasively monitor biological processes at the cellular and molecular level in vivo, including molecular imaging of nuclear medicine, magnetic resonance molecular imaging, ultrasound molecular imaging,optical molecular imaging and molecular imaging with X-ray. Recently, with the development of multi-subjects amalgamation, multimodal molecular imaging technology has been applied in clinical imaging, such as PET-CT and PET-MRI. We believe that with development of molecular probe and multi-modal imaging, more and more molecular imaging techniques will be applied in clinical diagnosis and treatment. (authors)

  13. Imaging Food Quality

    DEFF Research Database (Denmark)

    Møller, Flemming

    Imaging and spectroscopy have long been established methods for food quality control both in the laboratories and online. An ever increasing number of analytical techniques are being developed into imaging methods and existing imaging methods to contain spectral information. Images and especially...... spectral images contain large amounts of data which should be analysed appropriately by techniques combining structure and spectral information. This dissertation deals with how different types of food quality can be measured by imaging techniques, analysed with appropriate image analysis techniques...... and finally use the image data to predict or visualise food quality. A range of different food quality parameters was addressed, i.e. water distribution in bread throughout storage, time series analysis of chocolate milk stability, yoghurt glossiness, graininess and dullness and finally structure and meat...

  14. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  15. MRI findings in acute diffuse axonal injured patients

    International Nuclear Information System (INIS)

    Sato, Hidetaka

    2001-01-01

    Diffuse axonal injury (DAI) in the acute stage was clinically evaluated using magnetic resonance imaging (MRI), which is considered superior to computed tomography (CT) in detecting parenchymal brain lesions. MRI was disadvantageous, however, to patients suffering from acute severe head injury because of the long time required to construct imaging and unstable patient vital signs. We conducted MRI safely under a high magnetic field (1.5 tesla) in acute DAI by close observation and with nonmagnetic respirator and electrocardiographic monitoring. MRI was conducted in 95 patients diagnosed with DAI classified into mild (14), moderate (17) and severe (64) DAI by criteria established by Gennarelli (1986). In patients with mild or moderate DAI, CT revealed no lesion in the parenchymal area although MRI detected lesions in every case, mainly in cortical white matter or basal ganglia. In patients with severe DAI, CT revealed parenchymal lesions in 14 although MRI detected further lesions in cortical white matter, basal ganglia, corpus callosum and brainstem in every case. These results correspond well to the experimental model Gennarelli's. This study concluded that MRI was useful in assessing acute DAI patients. (author)

  16. Persistent atrial fibrillation vs paroxysmal atrial fibrillation: differences in management.

    Science.gov (United States)

    Margulescu, Andrei D; Mont, Lluis

    2017-08-01

    Atrial fibrillation (AF) is the most common human arrhythmia. AF is a progressive disease, initially being nonsustained and induced by trigger activity, and progressing towards persistent AF through alteration of the atrial myocardial substrate. Treatment of AF aims to decrease the risk of stroke and improve the quality of life, by preventing recurrences (rhythm control) or controlling the heart rate during AF (rate control). In the last 20 years, catheter-based and, less frequently, surgical and hybrid ablation techniques have proven more successful compared with drug therapy in achieving rhythm control in patients with AF. However, the efficiency of ablation techniques varies greatly, being highest in paroxysmal and lowest in long-term persistent AF. Areas covered: In this review, we discuss the fundamental differences between paroxysmal and persistent AF and the potential impact of those differences on patient management, emphasizing the available therapeutic strategies to achieve rhythm control. Expert commentary: Treatment to prevent AF recurrences is suboptimal, particularly in patients with persistent AF. Emerging technologies, such as documentation of atrial fibrosis using magnetic resonance imaging and documentation of electrical substrate using advanced electrocardiographic imaging techniques are likely to provide valuable insights about patient-specific tailoring of treatments.

  17. Remote Sensing Image Registration Using Multiple Image Features

    Directory of Open Access Journals (Sweden)

    Kun Yang

    2017-06-01

    Full Text Available Remote sensing image registration plays an important role in military and civilian fields, such as natural disaster damage assessment, military damage assessment and ground targets identification, etc. However, due to the ground relief variations and imaging viewpoint changes, non-rigid geometric distortion occurs between remote sensing images with different viewpoint, which further increases the difficulty of remote sensing image registration. To address the problem, we propose a multi-viewpoint remote sensing image registration method which contains the following contributions. (i A multiple features based finite mixture model is constructed for dealing with different types of image features. (ii Three features are combined and substituted into the mixture model to form a feature complementation, i.e., the Euclidean distance and shape context are used to measure the similarity of geometric structure, and the SIFT (scale-invariant feature transform distance which is endowed with the intensity information is used to measure the scale space extrema. (iii To prevent the ill-posed problem, a geometric constraint term is introduced into the L2E-based energy function for better behaving the non-rigid transformation. We evaluated the performances of the proposed method by three series of remote sensing images obtained from the unmanned aerial vehicle (UAV and Google Earth, and compared with five state-of-the-art methods where our method shows the best alignments in most cases.

  18. IMAGES OF DECOLONIZATION / IMAGES DE LA DECOLONISATION

    OpenAIRE

    Ganapathy-Doré , Geetha; Olinga , Michel; Crowley , Cornelius; Naumann , Michel; Le Boulicaut , Yannick; Coulardeau , Jacques; Taouchichet , Sofiane; Éric Owono Zambo , Claude; Dosoruth , Sonia; Vilar , Fernanda; Griffin , Patrick

    2013-01-01

    Il s'agit d'un document avec références.; International audience; This collected anthology of essays on the Images of Decolonization follows in the footsteps of an earlier SARI publication on Changing Images of India and Africa (Paris: L'Harmattan, 2011). It approaches the idea of decolonization from the point of view of the politics of representation with articles on the gaze of colonial and postcolonial photographers, the fantasized images of indigenous women (Pocahontas in the USA and La M...

  19. Image processing based detection of lung cancer on CT scan images

    Science.gov (United States)

    Abdillah, Bariqi; Bustamam, Alhadi; Sarwinda, Devvi

    2017-10-01

    In this paper, we implement and analyze the image processing method for detection of lung cancer. Image processing techniques are widely used in several medical problems for picture enhancement in the detection phase to support the early medical treatment. In this research we proposed a detection method of lung cancer based on image segmentation. Image segmentation is one of intermediate level in image processing. Marker control watershed and region growing approach are used to segment of CT scan image. Detection phases are followed by image enhancement using Gabor filter, image segmentation, and features extraction. From the experimental results, we found the effectiveness of our approach. The results show that the best approach for main features detection is watershed with masking method which has high accuracy and robust.

  20. The effect of image sharpness on quantitative eye movement data and on image quality evaluation while viewing natural images

    Science.gov (United States)

    Vuori, Tero; Olkkonen, Maria

    2006-01-01

    The aim of the study is to test both customer image quality rating (subjective image quality) and physical measurement of user behavior (eye movements tracking) to find customer satisfaction differences in imaging technologies. Methodological aim is to find out whether eye movements could be quantitatively used in image quality preference studies. In general, we want to map objective or physically measurable image quality to subjective evaluations and eye movement data. We conducted a series of image quality tests, in which the test subjects evaluated image quality while we recorded their eye movements. Results show that eye movement parameters consistently change according to the instructions given to the user, and according to physical image quality, e.g. saccade duration increased with increasing blur. Results indicate that eye movement tracking could be used to differentiate image quality evaluation strategies that the users have. Results also show that eye movements would help mapping between technological and subjective image quality. Furthermore, these results give some empirical emphasis to top-down perception processes in image quality perception and evaluation by showing differences between perceptual processes in situations when cognitive task varies.

  1. The Digital Image Processing And Quantitative Analysis In Microscopic Image Characterization

    International Nuclear Information System (INIS)

    Ardisasmita, M. Syamsa

    2000-01-01

    Many electron microscopes although have produced digital images, but not all of them are equipped with a supporting unit to process and analyse image data quantitatively. Generally the analysis of image has to be made visually and the measurement is realized manually. The development of mathematical method for geometric analysis and pattern recognition, allows automatic microscopic image analysis with computer. Image processing program can be used for image texture and structure periodic analysis by the application of Fourier transform. Because the development of composite materials. Fourier analysis in frequency domain become important for measure the crystallography orientation. The periodic structure analysis and crystal orientation are the key to understand many material properties like mechanical strength. stress, heat conductivity, resistance, capacitance and other material electric and magnetic properties. In this paper will be shown the application of digital image processing in microscopic image characterization and analysis in microscopic image

  2. A virtual image chain for perceived image quality of medical display

    Science.gov (United States)

    Marchessoux, Cédric; Jung, Jürgen

    2006-03-01

    This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.

  3. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  4. Image degradation characteristics and restoration based on regularization for diffractive imaging

    Science.gov (United States)

    Zhi, Xiyang; Jiang, Shikai; Zhang, Wei; Wang, Dawei; Li, Yun

    2017-11-01

    The diffractive membrane optical imaging system is an important development trend of ultra large aperture and lightweight space camera. However, related investigations on physics-based diffractive imaging degradation characteristics and corresponding image restoration methods are less studied. In this paper, the model of image quality degradation for the diffraction imaging system is first deduced mathematically based on diffraction theory and then the degradation characteristics are analyzed. On this basis, a novel regularization model of image restoration that contains multiple prior constraints is established. After that, the solving approach of the equation with the multi-norm coexistence and multi-regularization parameters (prior's parameters) is presented. Subsequently, the space-variant PSF image restoration method for large aperture diffractive imaging system is proposed combined with block idea of isoplanatic region. Experimentally, the proposed algorithm demonstrates its capacity to achieve multi-objective improvement including MTF enhancing, dispersion correcting, noise and artifact suppressing as well as image's detail preserving, and produce satisfactory visual quality. This can provide scientific basis for applications and possesses potential application prospects on future space applications of diffractive membrane imaging technology.

  5. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  6. A dual-view digital tomosynthesis imaging technique for improved chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng; Shaw, Chris C., E-mail: cshaw@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054 (United States)

    2015-09-15

    Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values

  7. Relation between exercise-induced ventricular arrhythmias and myocardial perfusion abnormalities in patients with intermediate pretest probability of coronary artery disease

    International Nuclear Information System (INIS)

    Elhendy, A.; Sozzi, F.B.; Van Domburg, R.T.; Bax, J.J.; Roelandt, J.R.T.C.

    2000-01-01

    We studied 302 patients (mean age 54±9 years, 152 men and 150 women) with intermediate pretest probability of CAD (range=0.25- 0.80, mean=0.43±0.20) by upright bicycle exercise stress test in conjunction with technetium-99m single-photon emission tomography (SPET) imaging. Exercise-induced VAs (frequent or complex premature ventricular contractions or ventricular tachycardia) occurred in 65 patients (22%). No significant difference was found between patients with and patient without VAs regarding the pretest probability of CAD (0.45±0.21 vs 0.43±0.20). Patients with exercise-induced VAs had a higher prevalence of perfusion abnormalities (52% vs 26%, P=0.002) and ischaemic electrocardiographic changes (31% vs 16%, P<0.05) compared to patients without VAs. A higher prevalence of perfusion abnormalities in patients with VAs was observed in both men (67% vs 35%, P<0.01) and women (38% vs 16%, P<0.05). However, the positive predictive value of exercise-induced VAs for the presence of myocardial perfusion abnormalities was higher in men than in women (67% vs 38%, P<0.05). The presence of abnormal myocardial perfusion was the only independent predictor of exercise-induced VAs (OR 2.2; 95% CI, 1.2-4.2) by multivariate analysis of clinical and stress test variables. It is concluded that in patients with intermediate pretest probability of CAD, exercise-induced VAs are predictive of a higher prevalence of myocardial perfusion abnormalities in both men and women. However, the positive predictive value of exercise-induced VAs for perfusion abnormalities is higher in men. Because of the underestimation of ischaemia by electrocardiographic changes, exercise-induced VAs should be interpreted as a marker of a higher probability of CAD. (orig./MG) (orig.)

  8. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  9. Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager

    International Nuclear Information System (INIS)

    Antonuk, Larry E.; Yorkston, John; Huang Weidong; Sandler, Howard; Siewerdsen, Jeffrey H.; El-Mohri, Youcef

    1996-01-01

    Purpose: The creation of the first large-area, amorphous silicon megavoltage imager is reported. The imager is an engineering prototype built to serve as a stepping stone toward the creation of a future clinical prototype. The engineering prototype is described and various images demonstrating its properties are shown including the first reported patient image acquired with such an amorphous silicon imaging device. Specific limitations in the engineering prototype are reviewed and potential advantages of future, more optimized imagers of this type are presented. Methods and Materials: The imager is based on a two-dimensional, pixelated array containing amorphous silicon field-effect transistors and photodiode sensors which are deposited on a thin glass substrate. The array has a 512 x 560-pixel format and a pixel pitch of 450 μm giving an imaging area of ∼23 x 25 cm 2 . The array is used in conjunction with an overlying metal plate/phosphor screen converter as well as an electronic acquisition system. Images were acquired fluoroscopically using a megavoltage treatment machine. Results: Array and digitized film images of a variety of anthropomorphic phantoms and of a human subject are presented and compared. The information content of the array images generally appears to be at least as great as that of the digitized film images. Conclusion: Despite a variety of severe limitations in the engineering prototype, including many array defects, a relatively slow and noisy acquisition system, and the lack of a means to generate images in a radiographic manner, the prototype nevertheless generated clinically useful information. The general properties of these amorphous silicon arrays, along with the quality of the images provided by the engineering prototype, strongly suggest that such arrays could eventually form the basis of a new imaging technology for radiotherapy localization and verification. The development of a clinically useful prototype offering high

  10. Stereo imaging and random array stratified imaging for cargo radiation inspecting

    International Nuclear Information System (INIS)

    Wang Jingjin; Zeng Yu

    2003-01-01

    This paper presents a Stereo Imaging and Random Array Stratified Imaging for cargo container radiation Inspecting. By using dual-line vertical detector array scan, a stereo image of inspected cargo can be obtained and watched with virtual reality view. The random detector array has only one-row of detectors but distributed in a certain horizontal dimension randomly. To scan a cargo container with this random array detector, a 'defocused' image is obtained. By using 'anti-random focusing', one layer of the image can be focused on the background of all defocused images from other layers. A stratified X-ray image of overlapped bike wheels is presented

  11. Complex adaptation-based LDR image rendering for 3D image reconstruction

    Science.gov (United States)

    Lee, Sung-Hak; Kwon, Hyuk-Ju; Sohng, Kyu-Ik

    2014-07-01

    A low-dynamic tone-compression technique is developed for realistic image rendering that can make three-dimensional (3D) images similar to realistic scenes by overcoming brightness dimming in the 3D display mode. The 3D surround provides varying conditions for image quality, illuminant adaptation, contrast, gamma, color, sharpness, and so on. In general, gain/offset adjustment, gamma compensation, and histogram equalization have performed well in contrast compression; however, as a result of signal saturation and clipping effects, image details are removed and information is lost on bright and dark areas. Thus, an enhanced image mapping technique is proposed based on space-varying image compression. The performance of contrast compression is enhanced with complex adaptation in a 3D viewing surround combining global and local adaptation. Evaluating local image rendering in view of tone and color expression, noise reduction, and edge compensation confirms that the proposed 3D image-mapping model can compensate for the loss of image quality in the 3D mode.

  12. Stereo Vision-Based High Dynamic Range Imaging Using Differently-Exposed Image Pair

    Directory of Open Access Journals (Sweden)

    Won-Jae Park

    2017-06-01

    Full Text Available In this paper, a high dynamic range (HDR imaging method based on the stereo vision system is presented. The proposed method uses differently exposed low dynamic range (LDR images captured from a stereo camera. The stereo LDR images are first converted to initial stereo HDR images using the inverse camera response function estimated from the LDR images. However, due to the limited dynamic range of the stereo LDR camera, the radiance values in under/over-exposed regions of the initial main-view (MV HDR image can be lost. To restore these radiance values, the proposed stereo matching and hole-filling algorithms are applied to the stereo HDR images. Specifically, the auxiliary-view (AV HDR image is warped by using the estimated disparity between initial the stereo HDR images and then effective hole-filling is applied to the warped AV HDR image. To reconstruct the final MV HDR, the warped and hole-filled AV HDR image is fused with the initial MV HDR image using the weight map. The experimental results demonstrate objectively and subjectively that the proposed stereo HDR imaging method provides better performance compared to the conventional method.

  13. Modified-BRISQUE as no reference image quality assessment for structural MR images.

    Science.gov (United States)

    Chow, Li Sze; Rajagopal, Heshalini

    2017-11-01

    An effective and practical Image Quality Assessment (IQA) model is needed to assess the image quality produced from any new hardware or software in MRI. A highly competitive No Reference - IQA (NR - IQA) model called Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) initially designed for natural images were modified to evaluate structural MR images. The BRISQUE model measures the image quality by using the locally normalized luminance coefficients, which were used to calculate the image features. The modified-BRISQUE model trained a new regression model using MR image features and Difference Mean Opinion Score (DMOS) from 775 MR images. Two types of benchmarks: objective and subjective assessments were used as performance evaluators for both original and modified-BRISQUE models. There was a high correlation between the modified-BRISQUE with both benchmarks, and they were higher than those for the original BRISQUE. There was a significant percentage improvement in their correlation values. The modified-BRISQUE was statistically better than the original BRISQUE. The modified-BRISQUE model can accurately measure the image quality of MR images. It is a practical NR-IQA model for MR images without using reference images. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Breast Imaging: The Face of Imaging 3.0.

    Science.gov (United States)

    Mayo, Ray Cody; Parikh, Jay R

    2016-08-01

    In preparation for impending changes to the health care delivery and reimbursement models, the ACR has provided a roadmap for success via the Imaging 3.0 (®)platform. The authors illustrate how the field of breast imaging demonstrates the following Imaging 3.0 concepts: value, patient-centered care, clinical integration, structured reporting, outcome metrics, and radiology's role in the accountable care organization environment. Much of breast imaging's success may be adapted and adopted by other fields in radiology to ensure that all radiologists become more visible and provide the value sought by patients and payers. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. OBJECT-SPACE MULTI-IMAGE MATCHING OF MOBILE-MAPPING-SYSTEM IMAGE SEQUENCES

    Directory of Open Access Journals (Sweden)

    Y. C. Chen

    2012-07-01

    Full Text Available This paper proposes an object-space multi-image matching procedure of terrestrial MMS (Mobile Mapping System image sequences to determine the coordinates of an object point automatically and reliably. This image matching procedure can be applied to find conjugate points of MMS image sequences efficiently. Conventional area-based image matching methods are not reliable to deliver accurate matching results for this application due to image scale variations, viewing angle variations, and object occlusions. In order to deal with these three matching problems, an object space multi-image matching is proposed. A modified NCC (Normalized Cross Correlation coefficient is proposed to measure the similarity of image patches. A modified multi-window matching procedure will also be introduced to solve the problem of object occlusion. A coarse-to-fine procedure with a combination of object-space multi-image matching and multi-window matching is adopted. The proposed procedure has been implemented for the purpose of matching terrestrial MMS image sequences. The ratio of correct matches of this experiment was about 80 %. By providing an approximate conjugate point in an overlapping image manually, most of the incorrect matches could be fixed properly and the ratio of correct matches was improved up to 98 %.

  16. Automatic tissue image segmentation based on image processing and deep learning

    Science.gov (United States)

    Kong, Zhenglun; Luo, Junyi; Xu, Shengpu; Li, Ting

    2018-02-01

    Image segmentation plays an important role in multimodality imaging, especially in fusion structural images offered by CT, MRI with functional images collected by optical technologies or other novel imaging technologies. Plus, image segmentation also provides detailed structure description for quantitative visualization of treating light distribution in the human body when incorporated with 3D light transport simulation method. Here we used image enhancement, operators, and morphometry methods to extract the accurate contours of different tissues such as skull, cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) on 5 fMRI head image datasets. Then we utilized convolutional neural network to realize automatic segmentation of images in a deep learning way. We also introduced parallel computing. Such approaches greatly reduced the processing time compared to manual and semi-automatic segmentation and is of great importance in improving speed and accuracy as more and more samples being learned. Our results can be used as a criteria when diagnosing diseases such as cerebral atrophy, which is caused by pathological changes in gray matter or white matter. We demonstrated the great potential of such image processing and deep leaning combined automatic tissue image segmentation in personalized medicine, especially in monitoring, and treatments.

  17. Animal Detection in Natural Images: Effects of Color and Image Database

    Science.gov (United States)

    Zhu, Weina; Drewes, Jan; Gegenfurtner, Karl R.

    2013-01-01

    The visual system has a remarkable ability to extract categorical information from complex natural scenes. In order to elucidate the role of low-level image features for the recognition of objects in natural scenes, we recorded saccadic eye movements and event-related potentials (ERPs) in two experiments, in which human subjects had to detect animals in previously unseen natural images. We used a new natural image database (ANID) that is free of some of the potential artifacts that have plagued the widely used COREL images. Color and grayscale images picked from the ANID and COREL databases were used. In all experiments, color images induced a greater N1 EEG component at earlier time points than grayscale images. We suggest that this influence of color in animal detection may be masked by later processes when measuring reation times. The ERP results of go/nogo and forced choice tasks were similar to those reported earlier. The non-animal stimuli induced bigger N1 than animal stimuli both in the COREL and ANID databases. This result indicates ultra-fast processing of animal images is possible irrespective of the particular database. With the ANID images, the difference between color and grayscale images is more pronounced than with the COREL images. The earlier use of the COREL images might have led to an underestimation of the contribution of color. Therefore, we conclude that the ANID image database is better suited for the investigation of the processing of natural scenes than other databases commonly used. PMID:24130744

  18. Animal detection in natural images: effects of color and image database.

    Directory of Open Access Journals (Sweden)

    Weina Zhu

    Full Text Available The visual system has a remarkable ability to extract categorical information from complex natural scenes. In order to elucidate the role of low-level image features for the recognition of objects in natural scenes, we recorded saccadic eye movements and event-related potentials (ERPs in two experiments, in which human subjects had to detect animals in previously unseen natural images. We used a new natural image database (ANID that is free of some of the potential artifacts that have plagued the widely used COREL images. Color and grayscale images picked from the ANID and COREL databases were used. In all experiments, color images induced a greater N1 EEG component at earlier time points than grayscale images. We suggest that this influence of color in animal detection may be masked by later processes when measuring reation times. The ERP results of go/nogo and forced choice tasks were similar to those reported earlier. The non-animal stimuli induced bigger N1 than animal stimuli both in the COREL and ANID databases. This result indicates ultra-fast processing of animal images is possible irrespective of the particular database. With the ANID images, the difference between color and grayscale images is more pronounced than with the COREL images. The earlier use of the COREL images might have led to an underestimation of the contribution of color. Therefore, we conclude that the ANID image database is better suited for the investigation of the processing of natural scenes than other databases commonly used.

  19. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  20. BMC Ecology Image Competition 2016: the winning images.

    Science.gov (United States)

    Simundza, Julia; Palmer, Matthew; Settele, Josef; Jacobus, Luke M; Hughes, David P; Mazzi, Dominique; Blanchet, Simon

    2016-08-09

    The 2016 BMC Ecology Image Competition marked another celebration of the astounding biodiversity, natural beauty, and biological interactions documented by talented ecologists worldwide. For our fourth annual competition, we welcomed guest judge Dr. Matthew Palmer of Columbia University, who chose the winning image from over 140 entries. In this editorial, we highlight the award winning images along with a selection of highly commended honorable mentions.