WorldWideScience

Sample records for electrical grounding

  1. Electrical Subsurface Grounding Analysis

    International Nuclear Information System (INIS)

    J.M. Calle

    2000-01-01

    The purpose and objective of this analysis is to determine the present grounding requirements of the Exploratory Studies Facility (ESF) subsurface electrical system and to verify that the actual grounding system and devices satisfy the requirements

  2. Electrical Ground System Design of PEFP

    International Nuclear Information System (INIS)

    Mun, Kyeong Jun; Jeon, Gye Po; Park, Sung Sik; Min, Yi Sub; Nam, Jung Min; Cho, Jang Hyung; Kim, Jun Yeon

    2010-01-01

    Since host site host site was selected Gyeong-ju city in January, 2006. we need design revision of Proton Accelerator research center to reflect on host site characteristics and several conditions. In this paper, electrical grounding and lightning protection design scheme is introduced. In electrical grounding system design of PEFP, we classified electrical facilities into 4 groups; equipment grounding (type A), instrument grounding (Type A), high frequency instrument grounding (Type C) and lightning arrestor grounding (Type D). Lightning protection system is designed in all buildings of proton accelerator research center of PEFP, including switchyard

  3. Electrical Ground System Design of PEFP

    Energy Technology Data Exchange (ETDEWEB)

    Mun, Kyeong Jun; Jeon, Gye Po; Park, Sung Sik; Min, Yi Sub; Nam, Jung Min; Cho, Jang Hyung; Kim, Jun Yeon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Since host site host site was selected Gyeong-ju city in January, 2006. we need design revision of Proton Accelerator research center to reflect on host site characteristics and several conditions. In this paper, electrical grounding and lightning protection design scheme is introduced. In electrical grounding system design of PEFP, we classified electrical facilities into 4 groups; equipment grounding (type A), instrument grounding (Type A), high frequency instrument grounding (Type C) and lightning arrestor grounding (Type D). Lightning protection system is designed in all buildings of proton accelerator research center of PEFP, including switchyard

  4. Ground electrical conductivity for medium wave activities over Nigeria

    African Journals Online (AJOL)

    Ground electrical properties remain a useful tool for most applications in engineering and communication, therefore, reliability and precision is highly required in their determination. Ground electrical conductivity as a function of signal frequency has been determined at Ilorin during the dry and the wet seasons. The study ...

  5. Year long variability of ground electrical conductivity in the sandy ...

    African Journals Online (AJOL)

    Ground electrical conductivity was measured continuously on a soil type in Nigeria for one year using the Model R-50 Soil Test Resistivity Meter Equipment. The Wenner arrangement of electrodes, which is one of the probe methods of ground resistivity measurement, was employed for the measurement. About 67% of all ...

  6. Electric Ground Support Equipment at Airports

    Energy Technology Data Exchange (ETDEWEB)

    2017-12-12

    Airport ground support equipment (GSE) is used to service airplanes between flights. Services include refueling, towing airplanes or luggage/freight carts, loading luggage/freight, transporting passengers, loading potable water, removing sewage, loading food, de-icing airplanes, and fire-fighting. Deploying new GSE technologies is a promising opportunity in part because the purchasers are generally large, technologically sophisticated airlines, contractors, or airports with centralized procurement and maintenance departments. Airlines could particularly benefit from fuel diversification since they are highly exposed to petroleum price volatility. GSE can be particularly well-suited for electrification because it benefits from low-end torque and has frequent idle time and short required ranges.

  7. The airborne radioactivity and electrical properties of ground level air

    International Nuclear Information System (INIS)

    Myslek-Laurikainen, B.; Matul, M.; Mikolajewski, S.; Trzaskowska, H.; Kubicki, M.

    2001-01-01

    The data presented in this work are the result of systematic measurements of radionuclide concentrations in air and density of vertical current. The airborne 7 Be concentration changes similar to the electrical conductivity of air, collected with an ASS-500 high volume air sampler of the ground atr monitoring network supervised by the Central Laboratory for Radiological Protection. Sampling has been done since March 1991. Simultaneously, the routine complex meteorological observations were performed. In particular, the electrical properties of ground level atmospheric air were studied with measurements of electrical field intensity, positive and negative conductivity of the air,while other isotopes, anthropogenic or originating from the ground are correlated with dust and other meteorological factors like watering and wind. (author)

  8. Grounding modelling for transient overvoltage simulation in electric power transmission

    International Nuclear Information System (INIS)

    Moreno O, German; Valencia V, Jaime A; Villada, Fernando

    1992-01-01

    Grounding plays an important role in transmission line outages and consequently on electric energy transmission quality indexes. Fundamentals of an accurate modelling for transient behaviour analysis, particularly for the response of transmission lines to lightning, are presented. Also, a method to take into account the electromagnetic propagation guided by the grounding electrodes and finally to assess the grounding impedance in order to simulate the transmission line behaviour under lightning is presented. Analysis of impedance behaviour for diverse configurations and simulation results of over voltages on a real 220 kV line are presented to illustrate the capabilities of the method and of the computational program developed

  9. Constellation Program Electrical Ground Support Equipment Research and Development

    Science.gov (United States)

    McCoy, Keegan S.

    2010-01-01

    At the Kennedy Space Center, I engaged in the research and development of electrical ground support equipment for NASA's Constellation Program. Timing characteristics playa crucial role in ground support communications. Latency and jitter are two problems that must be understood so that communications are timely and consistent within the Kennedy Ground Control System (KGCS). I conducted latency and jitter tests using Alien-Bradley programmable logic controllers (PLCs) so that these two intrinsic network properties can be reduced. Time stamping and clock synchronization also play significant roles in launch processing and operations. Using RSLogix 5000 project files and Wireshark network protocol analyzing software, I verified master/slave PLC Ethernet module clock synchronization, master/slave IEEE 1588 communications, and time stamping capabilities. All of the timing and synchronization test results are useful in assessing the current KGCS operational level and determining improvements for the future.

  10. System for detecting and limiting electrical ground faults within electrical devices

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1990-01-01

    This paper discusses, in a nuclear power plant of a variety wherein a reactor is provided including a reactor vessel retaining a liquid metal coolant, a reactor core and an electromagnetic pump having inductive windings insulatively retained within the electrically conductive wall of an enclosure, the method for controlling electrical ground fault current between a the inductive winding and the walls. It comprises providing an electrically isolated power source by inductive coupling with the plant power supply; rectifying the power source to provide an isolated d.c. power source; providing an inverter powered from the isolated d.c. power source under the control of the plant control system for selectively energizing the inductive windings; providing a fault control conductor electrically connected with the pump enclosure wall and extending as an electrical return for ground fault current to the inverter; and providing an electrical resistance between the conductor and the isolated inverter having an impedance selected to limit the fault current below a predetermined value limiting arc damage at any the electrical ground fault location

  11. IMPROVED ALGORITHM FOR CALCULATING COMPLEX NON-EQUIPOTENTIAL GROUNDING DEVICES OF ELECTRICAL INSTALLATIONS TAKING INTO ACCOUNT CONDUCTIVITY OF NATURAL GROUNDINGS

    Directory of Open Access Journals (Sweden)

    K. A. Starkov

    2017-08-01

    Full Text Available Purpose. The method of natural concentrated groundings substitution by the set of electrodes taking them into account in the algorithm of electric characteristics calculation for complicated grounding connections of electric installation is offered. An equivalent model as a set of linear electrodes is chosen in accordance with two criteria: leakage resistance and potentials on the ground surface. Methodology. We have applied induced potential method and methods for computing branched electrical circuits with distributed parameters. Results. We have obtained the algorithm for calculating complex non-equipotential grounding connections, which makes it possible to obtain refined values of the potential distribution in the electric stations and substations with outdoor switchgear. Originality. For the first time, we have taking into account the conductivity of natural concentrated grounds by a set of vertical and horizontal electrodes based on equivalent electrical characteristics applied to a two-layer ground. Practical value. The using of the proposed calculation algorithm in the electric grids of JSC «Kharkivoblenergo» made it possible to determine the values of the potential distribution at short circuit in electrical substation taking into account the influence of the conductivity of natural concentrated groundings.

  12. The on-line electric vehicle wireless electric ground transportation systems

    CERN Document Server

    Cho, Dong

    2017-01-01

    This book details the design and technology of the on-line electric vehicle (OLEV) system and its enabling wireless power-transfer technology, the “shaped magnetic field in resonance” (SMFIR). The text shows how OLEV systems can achieve their three linked important goals: reduction of CO2 produced by ground transportation; improved energy efficiency of ground transportation; and contribution to the amelioration or prevention of climate change and global warming. SMFIR provides power to the OLEV by wireless transmission from underground cables using an alternating magnetic field and the reader learns how this is done. This cable network will in future be part of any local smart grid for energy supply and use thereby exploiting local and renewable energy generation to further its aims. In addition to the technical details involved with design and realization of a fleet of vehicles combined with extensive subsurface charging infrastructure, practical issues such as those involved with pedestrian safety are c...

  13. Electric field studies: TLE-induced waveforms and ground conductivity impact on electric field propagation

    Science.gov (United States)

    Farges, Thomas; Garcia, Geraldine; Blanc, Elisabeth

    2010-05-01

    propagation of the electromagnetic waves generated by lightning has also been studied in the frequency range 1 kHz-1MHz at distances lower than 1000 km from the lightning source. A propagation model has been developed to determine the ground waves which propagate in a homogenous medium using the analytical expression given by Maclean and Wu [1993]. This approach takes into account the electric finite conductivity and the fact that the Earth is spherical, which allow us to deal with over-the-horizon propagation. We installed in 2008 four stations which were more or less aligned - the maximum distance between two stations was about 870 km. Two stations were located close to the Mediterranean Sea and the two others inside the continent, at the centre of France. This station distribution and the observation period (from August to December) allowed statistical and physical studies, such as the influence of the electric conductivity on wave propagation. Comparison of electric field spectra, measured after propagation only over sea and only over ground, showed clearly the effects of ground conductivity on propagation. Comparison between observations and modelling has been used to evaluate the ground conductivity. In the future we will implement the sky-wave inside our model and validate it with the database.

  14. Influence factor analysis of atmospheric electric field monitoring near ground under different weather conditions

    International Nuclear Information System (INIS)

    Wan, Haojiang; Wei, Guanghui; Cui, Yaozhong; Chen, Yazhou

    2013-01-01

    Monitoring of atmospheric electric field near ground plays a critical role in atmospheric environment detecting and lightning warning. Different environmental conditions (e.g. buildings, plants, weather, etc.) have different influences on the data's coherence in an atmospheric electric field detection network. In order to study the main influence factors of atmospheric electric field monitoring under different weather conditions, with the combination of theoretical analysis and experiments, the electric field monitoring data on the ground and on the top of a building are compared in fair weather and thunderstorm weather respectively in this paper. The results show that: In fair weather, the field distortion due to the buildings is the main influence factor on the electric field monitoring. In thunderstorm weather, the corona ions produced from the ground, besides the field distortion due to the buildings, can also influence the electric field monitoring results.

  15. Proposed design criteria for a fusion facility electrical ground system

    International Nuclear Information System (INIS)

    Armellino, C.A.

    1983-01-01

    Ground grid design considerations for a nuclear fusion reactor facility are no different than any other facility in that the basis for design must be safety first and foremost. Unlike a conventional industrial facility the available fault energy comes not only from the utility source and in-house rotating machinery, but also from energy storage capacitor banks, collapsing magnetic fields and D.C. transmission lines. It is not inconceivable for a fault condition occurrence where all available energy can be discharged. The ground grid must adequately shunt this sudden energy discharge in a way that personnel will not be exposed by step and/or touch to hazardous energy levels that are in excess of maximum tolerable levels for humans. Fault energy discharge rate is a function of the ground grid surge impedance characteristic. Closed loop paths must be avoided in the ground grid design so that during energy discharge no stray magnetic fields or large voltage potentials between remote points can be created by circulating currents. Single point connection of equipment to the ground grid will afford protection to personnel and sensitive equipment by reducing the probability of circulating currents. The overall ground grid system design is best illustrated as a wagon wheel concept with the fusion machine at the center. Radial branches or spokes reach out to the perimeter limits designated by step-and-touch high risk areas based on soil resistivity criteria considerations. Conventional methods for the design of a ground grid with all of its radial branches are still pertinent. The center of the grid could include a deep well single ground rod element the length of which is at least equivalent to the radius of an imaginary sphere that enshrouds the immediate machine area. Special facilities such as screen rooms or other shielded areas are part of the ground grid system by way of connection to radial branches

  16. Electrical crosstalk in integrated Mach-Zehnder modulators caused by a shared ground path

    NARCIS (Netherlands)

    Yao, W.; Gilardi, G.; Smit, M.K.; Wale, M.J.

    2015-01-01

    We show that the majority of electrical crosstalk between integrated Mach-Zehnder modulators can be caused by a shared ground path and demonstrate that in its absence crosstalk and related transmission penalty is greatly reduced.

  17. Electromagnetic Emission from Electric Propulsions under Ground Conditions

    Science.gov (United States)

    Baranov, S. V.; Vazhenin, N. A.; Plokhikh, A. P.; Popov, G. A.

    2017-12-01

    Analysis and methodological generalization of available methods used for determining characteristics of intrinsic emission from electric propulsions (EP) in a radio-frequency range that can be the interference for the "Earth-spacecraft (SC)" channel of the space communication system are the subjects of this paper. Intrinsic emission from the electric propulsion in a radio-frequency range is examined in detail by the example of a measuring complex developed in RIAME MAI and the measurement results are presented. The electric field intensity distribution in a radio-frequency range for the vertical and horizontal polarizations of the received emission is considered as the main characteristics. Measurements performed for the EP intrinsic emission by using the developed complex and measurements performed in metal vacuum chambers are compared and comparative results are presented in the paper.

  18. Helios Prototype on lakebed during ground check of electric motors

    Science.gov (United States)

    1999-01-01

    The Helios Prototype is an enlarged version of the Centurion flying wing, which flew a series of test flights at Dryden in late 1998. The craft has a wingspan of 247 feet, 41 feet greater than the Centurion, 2 1/2 times that of its solar-powered Pathfinder flying wing, and longer than either the Boeing 747 jetliner or Lockheed C-5 transport aircraft. Helios is one of several remotely-piloted aircraft-also known as uninhabited aerial vehicles or UAV's-being developed as technology demonstrators by several small airframe manufacturers under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. Developed by AeroVironment, Inc., of Monrovia, Calif., the unique craft is intended to demonstrate two key missions: the ability to reach and sustain horizontal flight at 100,000 feet altitude on a single-day flight, and to maintain flight above 50,000 feet altitude for at least four days, both on electrical power derived from non-polluting solar energy. During later flights, AeroVironment's flight test team will evaluate new motor-control software which may allow the pitch of the aircraft-the nose-up or nose-down attitude in relation to the horizon-to be controlled entirely by the motors. If successful, productions versions of the Helios could eliminate the elevators on the wing's trailing edge now used for pitch control, saving weight and increasing the area of the wing available for installation of solar cells.

  19. Decrease in Ground-Run Distance of Small Airplanes by Applying Electrically-Driven Wheels

    Science.gov (United States)

    Kobayashi, Hiroshi; Nishizawa, Akira

    A new takeoff method for small airplanes was proposed. Ground-roll performance of an airplane driven by electrically-powered wheels was experimentally and computationally studied. The experiments verified that the ground-run distance was decreased by half with a combination of the powered driven wheels and propeller without increase of energy consumption during the ground-roll. The computational analysis showed the ground-run distance of the wheel-driven aircraft was independent of the motor power when the motor capability exceeded the friction between tires and ground. Furthermore, the distance was minimized when the angle of attack was set to the value so that the wing generated negative lift.

  20. Hydrogeological characterisation using cross-borehole ground penetration radar and electrical resistivity tomography

    DEFF Research Database (Denmark)

    Zibar, Majken Caroline Looms

    2007-01-01

    was characterized by ~30 m thick unsaturated zone consisting mainly of sands of varying coarseness. Following an instrumentation of 16 boreholes two geophysical methods (cross-borehole ground penetrating radar and electrical resistivity tomography) were applied during natural precipitation and forced infiltration...... properties of the subsurface. On the other hand, volumetric moisture content variations of up to 5% were observed during a 20-day long forced infiltration experiment. The cross-borehole electrical resistance tomography and ground penetrating radar data collected during this experiment were subsequently....... The methods provided estimates of soil moisture content and electrical resistivity variations among 12 m deep boreholes located 5 – 7 m apart. The moisture content change following natural precipitation was observed to be practically negligible, providing minimal information to constrain the dynamic...

  1. Transfer of electrical space charge from corona between ground and thundercloud: Measurements and modeling

    Science.gov (United States)

    Soula, Serge

    1994-01-01

    The evolution of the vertical electric field profile deduced from simultaneous field measurements at several levels below a thundercloud shows the development of a space charge layer at least up to 600 m. The average charge density in the whole layer from 0 m to 600 m can reach about 1 nC m(exp -3). The ions are generated at the ground by corona effect and the production rate is evaluated with a new method from the comparison of field evolutions at the ground and at altitude after a lightning flash. The modeling of the relevant processes shows tht ground corona accounts for the observed field evolutions and that the aerosol particles concentration has a very large effect on the evolution of corona ions. However, with a realistic value for this concentration a large amount of ground corona ions reach the level of 600 m.

  2. Electronic ground support equipment for the Cluster Electric Field and Wave Experiment

    International Nuclear Information System (INIS)

    Sten, T.A.

    1992-10-01

    In a collaboration between ESA and NASA, ionosphere plasma structures will be studied by four indentical space probes to be launched in 1995 from French Guiana. The Electric Field and Wave (EFW) experiment will be designed to measure electric field and density fluctations by means of four sensors, each deployed on a 50 meter wire boom. In order to perform comprehensive tests and calibrations of the EFW experiment, computer controlled electronic ground support equipment has been developed. This report describes the hardware of the equipment, produced and assembled at the University of Oslo. 15 figs

  3. Kennedy Space Center: Constellation Program Electrical Ground Support Equipment Research and Development

    Science.gov (United States)

    McCoy, Keegan

    2010-01-01

    The Kennedy Space Center (KSC) is NASA's spaceport, launching rockets into space and leading important human spaceflight research. This spring semester, I worked at KSC on Constellation Program electrical ground support equipment through NASA's Undergraduate Student Research Program (USRP). This report includes a discussion of NASA, KSC, and my individual research project. An analysis of Penn State's preparation of me for an internship and my overall impressions of the Penn State and NASA internship experience conclude the report.

  4. Settlement process of radioactive dust to the ground inferred from the atmospheric electric field measurement

    Science.gov (United States)

    Yamauchi, M.; Takeda, M.; Makino, M.; Owada, T.; Miyagi, I.

    2012-01-01

    Radioactive materials from the accident at Fukushima Dai-ichi nuclear power plant (FNPP) in March 2011 spread over a large area, increasing the atmospheric electric conductivity by their ionizing effect, and reducing the vertical (downward) component of the DC electric field near the ground, or potential gradient (PG). PG data at Kakioka, 150 km away from the FNPP, showed independent changes compared to the radiation dose rate, and a comparison of these data revealed the local dynamics of the radioactive dust. (1) The initial drop of the PG to almost zero during 14-15 March is most likely due to radioactive dust suspended in the air near the ground during cloudy weather. (2) An episode of PG increase to more than 50 V m-1 on 16 March is most likely due to the re-suspension of the radioactive dust from the surface and subsequent removal from Kakioka by the strong wind from the non-contaminated area. (3) Low but finite values of the PG during 16-20 March most likely reflect a reduced amount of radioactive material near the ground after the above wind transported away the majority of the suspended radioactive dust. (4) Very low values of the PG after substantial rain on 20-22 March most likely reflect settlement of the radioactive material by rain-induced fallout. (5) Temporal recovery of daily variations from the end of March to the middle of April with low nighttime fair-weather baseline PG most likely reflects re-suspension of the radioactive dust into the air from the ground and trees, and subsequent transport to the other region or fallout to the ground until late April. (6) Weakening of the daily variation and gradual recovery of the nighttime fair-weather baseline after mid-April suggests a complete settlement of the radioactive material to the ground with partial migration to the subsurface.

  5. Settlement process of radioactive dust to the ground inferred from the atmospheric electric field measurement

    Directory of Open Access Journals (Sweden)

    M. Yamauchi

    2012-01-01

    Full Text Available Radioactive materials from the accident at Fukushima Dai-ichi nuclear power plant (FNPP in March 2011 spread over a large area, increasing the atmospheric electric conductivity by their ionizing effect, and reducing the vertical (downward component of the DC electric field near the ground, or potential gradient (PG. PG data at Kakioka, 150 km away from the FNPP, showed independent changes compared to the radiation dose rate, and a comparison of these data revealed the local dynamics of the radioactive dust. (1 The initial drop of the PG to almost zero during 14–15 March is most likely due to radioactive dust suspended in the air near the ground during cloudy weather. (2 An episode of PG increase to more than 50 V m−1 on 16 March is most likely due to the re-suspension of the radioactive dust from the surface and subsequent removal from Kakioka by the strong wind from the non-contaminated area. (3 Low but finite values of the PG during 16–20 March most likely reflect a reduced amount of radioactive material near the ground after the above wind transported away the majority of the suspended radioactive dust. (4 Very low values of the PG after substantial rain on 20–22 March most likely reflect settlement of the radioactive material by rain-induced fallout. (5 Temporal recovery of daily variations from the end of March to the middle of April with low nighttime fair-weather baseline PG most likely reflects re-suspension of the radioactive dust into the air from the ground and trees, and subsequent transport to the other region or fallout to the ground until late April. (6 Weakening of the daily variation and gradual recovery of the nighttime fair-weather baseline after mid-April suggests a complete settlement of the radioactive material to the ground with partial migration to the subsurface.

  6. Successful application of frequency-domain airborne electromagnetic system with a grounded electric source

    Science.gov (United States)

    Kang, L.; Lin, J.; Liu, C.; Zhou, H.; Ren, T.; Yao, Y.

    2017-12-01

    A new frequency-domain AEM system with a grounded electric source, which was called ground-airborne frequency-domain electromagnetic (GAFEM) system, was proposed to extend penetration depth without compromising the resolution and detection efficiency. In GAFEM system, an electric source was placed on the ground to enlarge the strength of response signals. UVA was chosen as aircraft to reduce interaction noise and improve its ability to adapt to complex terrain. Multi-source and multi-frequency emission method has been researched and applied to improve the efficiency of GAFEM system. 2n pseudorandom sequence was introduced as transmitting waveform, to ensure resolution and detection efficiency. Inversion-procedure based on full-space apparent resistivity formula was built to realize GAFEM method and extend the survey area to non-far field. Based on GAFEM system, two application was conducted in Changchun, China, to map the deep conductive structure. As shown in the results of this exploration, GAFEM system shows its effectiveness to conductive structure, obtaining a depth of about 1km with a source-receiver distance of over 6km. And it shows the same level of resolution with CSAMT method with an over 10 times of efficiency. This extended a range of important applications where the terrain is too complex to be accessed or large penetration depth is required in a large survey area.

  7. Ground water contamination by electrical prospecting; Denki tansaho ni yoru chikasui osen chosa

    Energy Technology Data Exchange (ETDEWEB)

    Irie, S; Fujii, Y; Sakaguchi, S; Ushijima, K [Kyushu University, Fukuoka (Japan). Faculty of Engineering

    1996-05-01

    A report is made about the result of vertical electric sounding conducted in the MK district, Fukuoka City, where Kyushu University is about to move. As for the method of electrical prospecting, in consideration of the need for probing a depth of 50m at the shallowest, vertical electrical sounding with a Schlumberger array of electrodes was employed. Measurements were made for 57 locations on the planar ground, the interval between electrodes gradually increased from 1 to 200m. In the 2D structure model analysis, a 2D inversion program was utilized in the ABIC minimization method. Also investigated were the relationship of electric prospecting and the geology, geological conditions, water level in the well, water quality, salt water, and pore rate from the previously-conducted investigative boring. As the result, it was estimated that the boundary between the first and second layers detected by electric prospecting reflected the level of underground water and that the boundary between the second and third layers reflected the portion where the N-value sharply increases. 4 refs., 8 figs.

  8. Goaf water detection using the grounded electrical source airborne transient electromagnetic system

    Science.gov (United States)

    Li, D.; Ji, Y.; Guan, S.; Wu, Y.; Wang, A.

    2017-12-01

    To detect the geoelectric characteristic of goaf water, the grounded electrical source airborne transient electromagnetic (GREATEM) system (developed by Jilin University, China) is applied to the goaf water detection since its advantages of considerable prospecting depth, lateral resolution and detection efficiency. For the test of GREATEM system in goaf water detection, an experimental survey was conducted at Qinshui coal mine (Shanxi province, China). After data acquisition, noise reduction and inversion, the resistivity profiles of survey area is presented. The results highly agree the investigation information provided by Shanxi Coal Geology Geophysical Surveying Exploration Institute (China), conforming that the GREATEM system is an effective technique for resistivity detection of goaf water.

  9. Modelling the Influence of Ground Surface Relief on Electric Sounding Curves Using the Integral Equations Method

    Directory of Open Access Journals (Sweden)

    Balgaisha Mukanova

    2017-01-01

    Full Text Available The problem of electrical sounding of a medium with ground surface relief is modelled using the integral equations method. This numerical method is based on the triangulation of the computational domain, which is adapted to the shape of the relief and the measuring line. The numerical algorithm is tested by comparing the results with the known solution for horizontally layered media with two layers. Calculations are also performed to verify the fulfilment of the “reciprocity principle” for the 4-electrode installations in our numerical model. Simulations are then performed for a two-layered medium with a surface relief. The quantitative influences of the relief, the resistivity ratios of the contacting media, and the depth of the second layer on the apparent resistivity curves are established.

  10. Atmospheric electric discharges and grounding systems; Descargas atmosfericas y sistemas de conexion a tierra

    Energy Technology Data Exchange (ETDEWEB)

    Rivas, Elena [ed.] [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    In this article the work made by the Institute of Investigaciones Electricas (IIE), in the area of atmospheric electric discharges and grounding connections at Comision Federal de Electricidad (CFE) is presented. The work consisted of the revision of the procedures for the design of transmission lines and substations of CFE from which high indexes of interruptions are reported, from this, a program was defined that allowed to improve the existing designs in CFE. [Spanish] En este articulo se presenta el trabajo realizado por el Instituto de Investigaciones Electricas (IIE), en el area de descargas atmosfericas y conexiones a tierra en Comision Federal de Electricidad (CFE). El trabajo consistio en la revision de los procedimientos de diseno de las areas de transmision y subestaciones de la CFE para los que se reportan altos indices de salidas, a partir de esto se definio un programa que permitio mejorar los disenos existentes en la CFE.

  11. Preparation of concrete mixtures with electric arc furnace slag and recycled ground glass

    Science.gov (United States)

    Pérez Rojas, Y.; López, E. Vera; López Rodríguez, M.; Díaz Pita, J.

    2017-12-01

    The present work includes the first advances in the development of investigations that seek to include Ground Grinding Glass (GRR) and the Electric Arc Furnace Slag (EAFS) in the production of mixtures of hydraulic concrete mixing them simultaneously, so that it satisfies the specifications techniques to be used in the construction of rigid pavements. Firstly, we cite the tests carried out on the different materials to obtain their physical, chemical and mechanical characterization and determine their compliance, as well as the measurement of certain characteristics that may be somewhat empirical to standardize their control. Technique such as X-Ray Diffraction (XRD), X-ray Fluorescence Spectrometry (XFR) and Scanning Electron Microscopy (SEM) have been used. Once the results of the characterization tests and their correspondence with the Colombian technical standards have been obtained, it has become possible to select the use of the Transparent Recycled Ground Glass (TRGG) as the most suitable for the replacement of the sand in the dosage of new mixtures modified concrete.

  12. A forward model for ground penetrating radar imaging of buried perfect electric conductors within the physical optics approximation

    DEFF Research Database (Denmark)

    Polat, Burak; Meincke, Peter

    2004-01-01

    A forward model for ground penetrating radar imaging of buried 3-D perfect electric conductors is addressed within the framework of diffraction tomography. The similarity of the present forward model derived within the physical optics approximation with that derived within the first Born...

  13. Detectability of underground electrical cables junction with a ground penetrating radar: electromagnetic simulation and experimental measurements

    Science.gov (United States)

    Liu, Xiang; serhir, mohammed; kameni, abelin; lambert, marc; pichon, lionel

    2016-04-01

    For a company like Electricity De France (EDF), being able to detect accurately using non-destructive methods the position of the buried junction between two underground cables is a crucial issue. The junction is the linking part where most maintenance operations are carried out. The challenge of this work is to conduct a feasibility study to confirm or deny the relevance of Ground Penetrating Radar (GPR) to detect these buried junctions in their actual environment against clutter. Indeed, the cables are buried in inhomogeneous medium at around 80cm deep. To do this, the study is conducted in a numerical environment. We use the 3D simulation software CST MWS to model a GPR scenario. In this simulation, we place the already optimized bowtie antennas operating in the frequency band [0.5 GHz - 3 GHz] in front of wet soil (dispersive) and dry soil where the underground cable is placed at 80cm deep. We collect the amplitude and phase of the reflected waves in order to detect the contrast provoked by the geometric dimensions variation of the cable [1] (diameter of the cable is 48mm and the diameter of the junction 74mm). The use of an ultra-wideband antenna is necessary to reconcile resolution and penetration of electromagnetic waves in the medium to be characterized. We focus on the performance of the GPR method according to the characteristics of the surrounding medium in which the electric cables are buried, the polarization of the Tx and Rx antennas. The experimental measurement collected in the EDF site will be presented. The measured data are processed using the clutter reduction method based on digital filtering [2]. We aim at showing that using the developed bowtie antennas that the GPR technique is well adapted for the cable junction localization even in cluttered environment. References [1] D. J. Daniels, "Surface-Penetrating Radar", London, IEE 1996. [2] Potin, D.; Duflos, E.; Vanheeghe, P., "Landmines Ground-Penetrating Radar Signal Enhancement by Digital

  14. 2-D Electrical Resistivity Tomography (ERT) Assessment of Ground Failure in Urban Area

    Science.gov (United States)

    Nordiana, M. M.; Bery, A. A.; Taqiuddin, Z. M.; Jinmin, M.; Abir, I. A.

    2018-04-01

    This study was carried out to assess the foundation defects around an urban area in Selangor, Malaysia using 2-D electrical resistivity tomography (ERT). The affected structure is a three storey houses and having severe foundation-based cracks. Six 2-D ERT survey lines with 5 m minimum electrode spacing using Pole-dipole array were executed parallel to building’s wall. Four boreholes were conducted to identify the depth to competent layer to verify the 2-D ERT results. Inversion model of 2-D resistivity show that the study area consists of two main zones. The first zone is a low resistivity value (resistivity values of 100-1000 Ωm at 20-70 m depth. The second zone is the granite bedrock of more than 3500 Ωm with depth greater than 70 m. These results were complimented and confirmed by borehole records. The ERT and borehole record suggest that the clay, sand, saturated zone, highly weathered zone and boulders at foundation depths may lead to ground movements which affected the stability of the building.

  15. Testing of ground fault relay response during the energisation of megawatt range electric boilers in thermal power plants

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth; Davidsen, Troels

    2015-01-01

    , with the advantage that the warmed water can be reused in a thermal power plant or at regional heating, thus, minimising the overall losses. However, one problem was raised by those purchasing the boilers, mainly the possibility of an unwanted triggering of the protections relays, especially ground fault protection...... for the testing of two ground fault protection relays, in order to assure that they are not triggered by the energisation of the boiler. The test is performed via an OMICRON CMC 256 with Advanced TransPlay SW, which generates the signals that would be present at the secondary of the instrumentation transformers......, during the energisation of a boiler. A special case for concern was the presence of an electric arc between the electrodes of the boiler and the water in the boiler during approximately 2s at the energisation, which can in theory be seen as a ground fault by the relay. The voltage and current transient...

  16. The influence of a vertical ground heat exchanger length on the electricity consumption of the heat pumps

    Energy Technology Data Exchange (ETDEWEB)

    Michopoulos, A.; Kyriakis, N. [Process Equipment Design Laboratory, Mechanical Engineer Department, Aristotle University of Thessaloniki (AUTh), P.O. Box 487, 541 24 Thessaloniki (Greece)

    2010-07-15

    The use of heat pumps combined with vertical ground heat exchangers for heating and cooling of buildings, has significantly gained popularity in recent years. The design method for these systems, as it is proposed by ASHRAE, is taking into account the maximum thermal and cooling loads of the building, the thermophysical properties of the soil at the area of installation and a minimum Coefficient of Performance (COP) of the heat pumps. This approach usually results in larger than needed length of the ground heat exchanger, thus increasing the installation cost. A new analytical simulation tool, capable to determine the required ground heat exchanger length has been developed at the Process Equipment Design Laboratory (PEDL) of the AUTh. It models the function of the system as a whole over long time periods, e.g. 20 years, using as input parameters the thermal and cooling loads of the building, the thermophysical properties of the borehole and the characteristic curves of the heat pumps. The results include the electricity consumption of the heat pumps and the heat absorbed from or rejected to the ground. The aim of this paper is to describe the developed simulation algorithm and present the results of such a simulation in a case study. It is proved that the total required length of the ground heat exchanger is less than that calculated using the common numerical method. (author)

  17. BEHAVIOUR OF BACKFILL MATERIALS FOR ELECTRICAL GROUNDING SYSTEMS UNDER HIGH VOLTAGE CONDITIONS

    Directory of Open Access Journals (Sweden)

    S. C. LIM

    2015-06-01

    Full Text Available Backfill materials like Bentonite and cement are effective in lowering grounding resistance of electrodes for a considerable period. During lightning, switching impulses and earth fault occurrences in medium and high voltage networks, the grounding system needs to handle extremely high currents either for a short duration or prolonged period respectively. This paper investigates the behaviour of bentonite, cement and sand under impulse and alternating high voltage (50Hz conditions. Fulguritic-formation was observed in all materials under alternating high voltage. The findings reveal that performance of grounding systems under high voltage conditions may significantly change from the outcomes anticipated at design stage.

  18. Defining Electric Potential Difference by Moving a Multimeter's Ground Probe

    Science.gov (United States)

    Stoeckel, Marta R.

    2018-01-01

    The abstract nature of electric potential difference (voltage) can make it a difficult concept to grasp, but understanding the relative nature of voltage is central to developing a conceptual understanding of electric circuits. In laboratory situations, I see these conceptual difficulties manifest when students have difficulty placing voltmeter…

  19. High-resolution electrical resistivity tomography applied to patterned ground, Wedel Jarlsberg Land, south-west Spitsbergen

    Directory of Open Access Journals (Sweden)

    Marek Kasprzak

    2015-06-01

    Full Text Available This article presents results of two-dimensional electrical resistivity tomography (ERT applied to three types of patterned ground in Wedel-Jarlsberg Land (Svalbard, carried out in late July 2012. The structures investigated include sorted circles, non-sorted polygons and a net with sorted coarser material. ERT was used to recognize the internal ground structure, the shape of permafrost table below the active layer and the geometric relationships between permafrost, ground layering and surface patterns. Results of inversion modelling indicate that the permafrost table occurs at a depth of 0.5–1 m in a mountain valley and 1–2.5 m on raised marine terraces. The permafrost table was nearly planar beneath non-sorted deposits and wavy beneath sorted materials. The mutual relationships between the permafrost table and the shape of a stone circle are different from those typically presented in literature. Ground structure beneath the net with sorted coarser materials is complex as implied in convective models. In non-sorted polygons, the imaging failed to reveal vertical structures between them.

  20. Analysis of the charge exchange between the human body and ground: evaluation of "earthing" from an electrical perspective.

    Science.gov (United States)

    Chamberlin, Kent; Smith, Wayne; Chirgwin, Christopher; Appasani, Seshank; Rioux, Paul

    2014-12-01

    The purpose of this study was to investigate "earthing" from an electrical perspective through measurement and analysis of the naturally occurring electron flow between the human body or a control and ground as this relates to the magnitude of the charge exchange, the relationship between the charge exchange and body functions (respiration and heart rate), and the detection of other information that might be contained in the charge exchange. Sensitive, low-noise instrumentation was designed and fabricated to measure low-level current flow at low frequencies. This instrumentation was used to record current flow between human subjects or a control and ground, and these measurements were performed approximately 40 times under varied circumstances. The results of these measurements were analyzed to determine if information was contained in the current exchange. The currents flowing between the human body and ground were small (nanoamperes), and they correlated with subject motion. There did not appear to be any information contained in this exchange except for information about subject motion. This study showed that currents flow between the environment (earth) and a grounded human body; however, these currents are small (nanoamperes) and do not appear to contain information other than information about subject motion.

  1. Effects of the addition of functional electrical stimulation to ground level gait training with body weight support after chronic stroke.

    Science.gov (United States)

    Prado-Medeiros, Christiane L; Sousa, Catarina O; Souza, Andréa S; Soares, Márcio R; Barela, Ana M F; Salvini, Tania F

    2011-01-01

    The addition of functional electrical stimulation (FES) to treadmill gait training with partial body weight support (BWS) has been proposed as a strategy to facilitate gait training in people with hemiparesis. However, there is a lack of studies that evaluate the effectiveness of FES addition on ground level gait training with BWS, which is the most common locomotion surface. To investigate the additional effects of commum peroneal nerve FES combined with gait training and BWS on ground level, on spatial-temporal gait parameters, segmental angles, and motor function. Twelve people with chronic hemiparesis participated in the study. An A1-B-A2 design was applied. A1 and A2 corresponded to ground level gait training using BWS, and B corresponded to the same training with the addition of FES. The assessments were performed using the Modified Ashworth Scale (MAS), Functional Ambulation Category (FAC), Rivermead Motor Assessment (RMA), and filming. The kinematics analyzed variables were mean walking speed of locomotion; step length; stride length, speed and duration; initial and final double support duration; single-limb support duration; swing period; range of motion (ROM), maximum and minimum angles of foot, leg, thigh, and trunk segments. There were not changes between phases for the functional assessment of RMA, for the spatial-temporal gait variables and segmental angles, no changes were observed after the addition of FES. The use of FES on ground level gait training with BWS did not provide additional benefits for all assessed parameters.

  2. Electrical-field-induced magnetic Skyrmion ground state in a two-dimensional chromium tri-iodide ferromagnetic monolayer

    Science.gov (United States)

    Liu, Jie; Shi, Mengchao; Mo, Pinghui; Lu, Jiwu

    2018-05-01

    Using fully first-principles non-collinear self-consistent field density functional theory (DFT) calculations with relativistic spin-orbital coupling effects, we show that, by applying an out-of-plane electrical field on a free-standing two-dimensional chromium tri-iodide (CrI3) ferromagnetic monolayer, the Néel-type magnetic Skyrmion spin configurations become more energetically-favorable than the ferromagnetic spin configurations. It is revealed that the topologically-protected Skyrmion ground state is caused by the breaking of inversion symmetry, which induces the non-trivial Dzyaloshinskii-Moriya interaction (DMI) and the energetically-favorable spin-canting configuration. Combining the ferromagnetic and the magnetic Skyrmion ground states, it is shown that 4-level data can be stored in a single monolayer-based spintronic device, which is of practical interests to realize the next-generation energy-efficient quaternary logic devices and multilevel memory devices.

  3. Integration of electrical resistivity imaging and ground penetrating radar to investigate solution features in the Biscayne Aquifer

    Science.gov (United States)

    Yeboah-Forson, Albert; Comas, Xavier; Whitman, Dean

    2014-07-01

    The limestone composing the Biscayne Aquifer in southeast Florida is characterized by cavities and solution features that are difficult to detect and quantify accurately because of their heterogeneous spatial distribution. Such heterogeneities have been shown by previous studies to exert a strong influence in the direction of groundwater flow. In this study we use an integrated array of geophysical methods to detect the lateral extent and distribution of solution features as indicative of anisotropy in the Biscayne Aquifer. Geophysical methods included azimuthal resistivity measurements, electrical resistivity imaging (ERI) and ground penetrating radar (GPR) and were constrained with direct borehole information from nearby wells. The geophysical measurements suggest the presence of a zone of low electrical resistivity (from ERI) and low electromagnetic wave velocity (from GPR) below the water table at depths of 4-9 m that corresponds to the depth of solution conduits seen in digital borehole images. Azimuthal electrical measurements at the site reported coefficients of electrical anisotropy as high as 1.36 suggesting the presence of an area of high porosity (most likely comprising different types of porosity) oriented in the E-W direction. This study shows how integrated geophysical methods can help detect the presence of areas of enhanced porosity which may influence the direction of groundwater flow in a complex anisotropic and heterogeneous karst system like the Biscayne Aquifer.

  4. Monitoring the ground water level change during the pump test by using the Electric resistivity tomography

    Science.gov (United States)

    Hsu, H.; Chang, P. Y.; Yao, H. J.

    2017-12-01

    For hydrodynamics study of the unconfined aquifer in gravel formation, a pumping test was established to estimate the hydraulic conductivity in the midstream of Zhoushui River in Taiwan. The hydraulic parameters and the cone of depression could be estimated by monitoring the groundwater drawdown in an observation well which was in a short distance far from the pumping well. In this study we carried out the electric resistivity image monitoring during the whole pumping test. The electric resistivity data was measured with the surface and downhole electrodes which would produce a clear subsurface image of groundwater level through a larger distance than the distance between pumping and observation wells. The 2D electric image could also describe how a cone of depression truly created at subsurface. The continuous records could also show the change of groundwater level during the whole pumping test which could give a larger scale of the hydraulic parameters.

  5. GROUNDING THE REDUCTION OF POWER OF THE HYDRAULIC DRIVE ELECTRIC MOTOR BY EQUIVALENT POWER METHOD

    Directory of Open Access Journals (Sweden)

    O. Hrygorov

    2017-06-01

    Full Text Available The authors have analyzed the power consumption by a hydraulic drive and wound rotor motor of crane mechanisms at all stages of the operational cycle: acceleration, movement at nominal or intermediate speed and deceleration. The decrease of the rated capacity of electric motors is justified.

  6. Electrical discharge occurring between a negatively charged particle cloud and a grounded sphere electrode

    International Nuclear Information System (INIS)

    Higashiyama, Y; Migita, S; Toki, K; Sugimoto, T

    2008-01-01

    Electrostatic discharge occurring between a space-charge cloud and a grounded object was investigated using a large-scale charged particle cloud formed by using three set of cloud generators consisting of a blower and corona charger. The ejecting velocity of the particles affects the formation of the charged cloud. At the lower velocity, the charged cloud spread due to electrostatic repulsion force, while at the higher velocity cloud forms an elongated conical shape. To cause electrostatic discharge between the cloud and a grounded object, a grounded sphere electrode with 100 mm in diameter was set at the inside or outside of the cloud. The brush-like discharge channels reached the maximum length of 0.55 m. The discharge current has a waveform with single or multi-peak, a current peak of several amperes, the maximum charge quantity of 2 μC, and the duration of several microseconds. The relationship between the charge quantity and the current peak or the duration in each discharge was examined. The discharge between the cloud and the electrode placed at the outside of the cloud has relatively longer channels and multi-peak current with the longer duration, while that at the inside of the cloud has the lower charge quantity with single peak.

  7. Continuous day-time time series of E-region equatorial electric fields derived from ground magnetic observatory data

    Science.gov (United States)

    Alken, P.; Chulliat, A.; Maus, S.

    2012-12-01

    The day-time eastward equatorial electric field (EEF) in the ionospheric E-region plays an important role in equatorial ionospheric dynamics. It is responsible for driving the equatorial electrojet (EEJ) current system, equatorial vertical ion drifts, and the equatorial ionization anomaly (EIA). Due to its importance, there is much interest in accurately measuring and modeling the EEF. However, there are limited sources of direct EEF measurements with full temporal and spatial coverage of the equatorial ionosphere. In this work, we propose a method of estimating a continuous day-time time series of the EEF at any longitude, provided there is a pair of ground magnetic observatories in the region which can accurately track changes in the strength of the EEJ. First, we derive a climatological unit latitudinal current profile from direct overflights of the CHAMP satellite and use delta H measurements from the ground observatory pair to determine the magnitude of the current. The time series of current profiles is then inverted for the EEF by solving the governing electrodynamic equations. While this method has previously been applied and validated in the Peruvian sector, in this work we demonstrate the method using a pair of magnetometers in Africa (Samogossoni, SAM, 0.18 degrees magnetic latitude and Tamanrasset, TAM, 11.5 degrees magnetic latitude) and validate the resulting EEF values against the CINDI ion velocity meter (IVM) instrument on the C/NOFS satellite. We find a very good 80% correlation with C/NOFS IVM measurements and a root-mean-square difference of 9 m/s in vertical drift velocity. This technique can be extended to any pair of ground observatories which can capture the day-time strength of the EEJ. We plan to apply this work to more observatory pairs around the globe and distribute real-time equatorial electric field values to the community.

  8. The electric dipole moments in the ground states of gold oxide, AuO, and gold sulfide, AuS.

    Science.gov (United States)

    Zhang, Ruohan; Yu, Yuanqin; Steimle, Timothy C; Cheng, Lan

    2017-02-14

    The B 2 Σ - - X 2 Π 3/2 (0,0) bands of a cold molecular beam sample of gold monoxide, AuO, and gold monosulfide, AuS, have been recorded at high resolution both field free and in the presence of a static electric field. The observed electric field induced splittings and shifts were analyzed to produce permanent electric dipole moments, μ→ el , of 2.94±0.06 D and 2.22±0.05 D for the X 2 Π 3/2 (v = 0) states of AuO and AuS, respectively. A molecular orbital correlation diagram is used to rationalize the trend in ground state μ→ el values for AuX (X = F, Cl, O, and S) molecules. The experimentally determined μ→ el are compared to those computed at the coupled-cluster singles and doubles (CCSD) level augmented with a perturbative inclusion of triple excitations (CCSD(T)) level of theory.

  9. Energized CO{sub 2} dry ice blast cleaning firmly grounded in the Canadian electrical industry

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, K.

    1999-02-01

    Development and use of energized carbon dioxide dry ice blast technology for cleaning electrical distribution system components by Oakville Hydro and Milton Hydro (both in Ontario) is discussed. The technology was developed by Alpheus Cleaning Technologies of California and Puget Sound Power and Light Company after a two-year study that commenced in 1991, and has been supplied in Canada by Wickens Industrial Ltd., since 1993 for cleaning various industrial and non-energized electrical applications in the automotive, printing , food processing and other manufacturing industries and hydro generating facilities. The unique cleaning dynamics of this technology allow for the removal of contaminants that are much more stubborn than those encountered in pad-mounted switchgear and other electrical apparatus. Dry ice pellets, by expanding to 400 times their solid state on impact, create a flushing action that helps to remove contaminants. No grit or solvents are required and the process is non-toxic. In using the process workers wear fire retardant clothing, 40 kV-Class 4 rubber gloves and full face shields. Dielectric tests are performed routinely to confirm the dielectric integrity of the spray wand components. A two stage inspection/trouble report is completed on every job. Use of this technology eliminates power interruptions to customers, improves system reliability and safety, reduces cleaning time to a minimum, and eliminated the need for reclamation of grit or solvent containment.

  10. Quantum electrodynamics at strong electric fields. The ground state Lamb shift in hydrogenlike uranium

    Energy Technology Data Exchange (ETDEWEB)

    Gumberidze, A.; Stoehlker, T. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)]|[Frankfurt Univ. (Germany). Inst. fuer Kernphysik; Banas, D. [Pedagogical Univ., Kielce (PL). Inst. of Phys.] [and others

    2005-05-01

    X-ray spectra following radiative recombination of free electrons with bare uranium ions (U{sup 92+}) were measured at the electron cooler of the ESR storage ring. The most intense lines observed in the spectra can be attributed to the characteristic Lyman ground-state transitions and to the recombination of free electrons into the K-shell of the ions. Our experiment was carried out by utilizing the deceleration technique which leads to a considerable reduction of the uncertainties associated with Doppler corrections. This, in combination with the 0 observation geometry, allowed us to determine the ground-state Lamb shift in hydrogen-like uranium (U{sup 91+}) from the observed X-ray lines with an accuracy of 1%. The present result is about 3 times more precise than the most accurate value available up to now and provides the most stringent test of bound-state quantum electrodynamics for one-electron systems in the strong-field regime. (orig.)

  11. Motion Control of Four-Wheel Independently Actuated Electric Ground Vehicles considering Tire Force Saturations

    Directory of Open Access Journals (Sweden)

    Rongrong Wang

    2013-01-01

    Full Text Available A vehicle stability control approach for four-wheel independently actuated (FWIA electric vehicles is presented. The proposed control method consists of a higher-level controller and a lower-level controller. An adaptive control-based higher-level controller is designed to yield the vehicle virtual control efforts to track the desired vehicle motions due to the possible modeling inaccuracies and parametric uncertainties. The lower-level controller considering tire force saturation is given to allocate the required control efforts to the four in-wheel motors for providing the desired tire forces. An analytic method is given to distribute the high-level control efforts, without using the numerical-optimization-based control allocation algorithms. Simulations based on a high-fidelity, CarSim, and full-vehicle model show the effectiveness of the control approach.

  12. Electric dipole moment function and line intensities for the ground state of carbon monxide

    International Nuclear Information System (INIS)

    Chen Hua-Jun; Cheng Xin-Lu; Wu Jie; Liu Hao

    2015-01-01

    An accurate electric dipole moment function (EDMF) is obtained for the carbon monoxide (CO) molecule (X 1 Σ + ) by fitting the experimental rovibrational transitional moments. Additionally, an accurate ab initio EDMF is found using the highly accurate, multi-reference averaged coupled-pair functional (ACPF) approach with the basis set, aug-cc-pV6Z, and a finite-field with ±0.005 a.u. (The unit a.u. is the abbreviation of atomic unit). This ab initio EDMF is very consistent with the fitted ones. The vibrational transition matrix moments and the Herman–Wallis factors, calculated with the Rydberg–Klein–Rees (RKR) potential and the fitted and ab initio EDMFs, are compared with experimental measurements. The consistency of these line intensities with the high-resolution transmission (HITRAN) molecular database demonstrates the improved accuracy of the fitted and ab initio EDMFs derived in this work. (paper)

  13. European Utility Requirements: leveling the European electricity producers' playing ground for new NPPs

    International Nuclear Information System (INIS)

    Bernard Roche

    2006-01-01

    Full text of publication follows: Since 1992, the European Utility Requirement (EUR) document has been developed by the major European electricity producers. The main driver to this work has been the construction of a unified European market. The electricity producers have set out design requirements adapted to this new European environment, while keeping in mind experience feedback from operating NPPs worldwide. The EUR document is now fully operational and its set of generic requirements have been recently used as bid specification in Finland and in China. The EUR document keeps developing in two directions: 1- completing the assessment of the projects that could be proposed by the vendors for the European market. Five projects have been assessed between 1999 and 2002: BWR90, EPR, EP1000, ABWR and SWR1000. Two new projects are being assessed, the Westinghouse AP1000 and the Russian VVER AES92. It is currently planned to publish these two new assessments in the first half of 2006. Others may be undertaken meanwhile. 2- revision of the generic requirements. A revision C of the volume 4 dedicated to power generation plant is being completed. It includes responses to vendors comments and feedback from the TVO call for bid for Finland 5. A revision D of the volumes 1 and 2 dedicated to nuclear islands is foreseen. The main contributions to this revision are the harmonization actions going on in Europe about nuclear safety (WENRA study on reactor safety harmonization, EC works, evolution of the IAEA guides and requirements), the harmonization works on the conditions of connection to the European HV grid as well as harmonization works on other matters, like codes and standards. This has given a unified frame in which the future nuclear plants can be designed and built. In this frame development of standards designs usable throughout Europe without major design change is possible, thus helping to increase competition, and ultimately to save investment and operating costs

  14. Assessment of MTI Water Temperature Retrievals with Ground Truth from the Comanche Peak Steam Electric Station Cooling Lake

    International Nuclear Information System (INIS)

    Kurzeja, R.J.

    2002-01-01

    Surface water temperatures calculated from Multispectral Thermal Imager (MTI) brightness temperatures and the robust retrieval algorithm, developed by the Los Alamos National Laboratory (LANL), are compared with ground truth measurements at the Squaw Creek reservoir at the Comanche Peak Steam Electric Station near Granbury Texas. Temperatures calculated for thirty-four images covering the period May 2000 to March 2002 are compared with water temperatures measured at 10 instrumented buoy locations supplied by the Savannah River Technology Center. The data set was used to examine the effect of image quality on temperature retrieval as well as to document any bias between the sensor chip arrays (SCA's). A portion of the data set was used to evaluate the influence of proximity to shoreline on the water temperature retrievals. This study found errors in daytime water temperature retrievals of 1.8 C for SCA 2 and 4.0 C for SCA 1. The errors in nighttime water temperature retrievals were 3.8 C for SCA 1. Water temperature retrievals for nighttime appear to be related to image quality with the largest positive bias for the highest quality images and the largest negative bias for the lowest quality images. The daytime data show no apparent relationship between water temperature retrieval error and image quality. The average temperature retrieval error near open water buoys was less than corresponding values for the near-shore buoys. After subtraction of the estimated error in the ground truth data, the water temperature retrieval error was 1.2 C for the open-water buoys compared to 1.8 C for the near-shore buoys. The open-water error is comparable to that found at Nauru

  15. Electric field conjugation for ground-based high-contrast imaging: robustness study and tests with the Project 1640 coronagraph

    Science.gov (United States)

    Matthews, Christopher T.; Crepp, Justin R.; Vasisht, Gautam; Cady, Eric

    2017-10-01

    The electric field conjugation (EFC) algorithm has shown promise for removing scattered starlight from high-contrast imaging measurements, both in numerical simulations and laboratory experiments. To prepare for the deployment of EFC using ground-based telescopes, we investigate the response of EFC to unaccounted for deviations from an ideal optical model. We explore the linear nature of the algorithm by assessing its response to a range of inaccuracies in the optical model generally present in real systems. We find that the algorithm is particularly sensitive to unresponsive deformable mirror (DM) actuators, misalignment of the Lyot stop, and misalignment of the focal plane mask. Vibrations and DM registration appear to be less of a concern compared to values expected at the telescope. We quantify how accurately one must model these core coronagraph components to ensure successful EFC corrections. We conclude that while the condition of the DM can limit contrast, EFC may still be used to improve the sensitivity of high-contrast imaging observations. Our results have informed the development of a full EFC implementation using the Project 1640 coronagraph at Palomar observatory. While focused on a specific instrument, our results are applicable to the many coronagraphs that may be interested in employing EFC.

  16. Application of Vertical Electrical Sounding (VES) for the assessment of Ground Water Potential at Madi Phant, Palpa District, Western Nepal

    Science.gov (United States)

    Khatiwada, B.; Ghimire, H.; Bhusal, U. C.; Shrestha, S. R.; Upadhyay, K.; Khanal, A.; Pandey, D.

    2017-12-01

    Ground Water Resources Development Board (GWRDB), Government of Nepal, is the sole authority for systematize investigation, and management of ground water in the country. This study was conducted by GWRDB to create a data base of the groundwater potential in the hilly area. The main purpose of the study was to assess the groundwater potential at the Madi Phant Valley, Lesser Himalaya Region, Plapa District, Nepal. Data were acquired from WDJD-4 and analyzed using computer aided software called IPI2win, which yield an automatic interpretation of the apparent resistivity and data were correlated with lithologs of the vertical section. The simulated results of the ten VES points conducted using Schlumberger Configuration with AB/2 varying from 2 to 400 m and MN/2 varying from 0.5 to 50m reveal the presence of 4 to 8 geo-electric layers. Results obtained from software were rechecked by plotting the apparent resistivity value on Log-Log transparent graph sheet and manually interpreted using master curves and auxiliary curves. The resistivity values of the different layers' ranges from 3 Ωm to 3700 Ωm and were statistically analyzed from Golden Software Grapher. Representative resistivity sounding curves with modeled layer obtained after inversion was used to delineate the aquifer and 1D geoelectric sections. The geoelectrical sections for the study area consists of: the topsoil, sandy silt, sand and gravel, fractured rock and the fresh basement rock. The groundwater bearing layer of fractured rock varies between depth of 8-65 meters across foothill site (Eastern Corner) of the study area and groundwater bearing layer of sand and gravel/fractured rock varies between depth of 20-100 m in the central part of the Madi Phant valley. Contour map and 3D map of bedrock and water bearing layers for the conceptual model were prepared with the help of surfer shows that the gradient of the contour is high in the surrounding parts and flat in the center of Valley.

  17. The Use of Ground Penetrating Radar and Electrical Resistivity Imaging for the Characterisation of Slope Movements in Expansive Marls

    Science.gov (United States)

    Rey, Isabel; Martínez, Julián; Cortada, Unai; Hildago, Mª Carmen

    2017-04-01

    Slope movements are one of the natural hazards that most affect linear projects, becoming an important waste of money and time for building companies. Thus, studies to identify the processes that provoke these movements, as well as to characterise the landslides are necessary. For this purpose, geophysical prospecting techniques as Ground Penetrating Radar (GPR) and Electrical Resistivity Imaging (ERI) could become useful. However, the effectiveness of these techniques in slope movement characterisation is affected by many factors, like soil humidity, grain size or failure plane depth. Therefore, studies that determine the usefulness of these techniques in different kind of soils and slope movements are required. In this study, GPR and ERI techniques efficiency for the analysis of slope movements in Upper Miocene expansive marls was evaluated. In particular, two landslides in an old regional road in the province of Jaen (Spain) were studied. A total of 53 GPR profiles were made, 31 with a 250 MHz frequency antenna and 22 with an 800 MHz frequency antenna. Marl facies rapidly attenuated the signal of the electromagnetic waves, which means that this technique only provided information of the first two meters of the subsoil. In spite of this low depth of penetration, it is necessary to point out the precision and detail undertaken. Thus, both GPR antennas gave information of the thicknesses and quality-continuity of the different soil layers. In addition, several restoration phases of the linear work were detected. Therefore, this technique was useful to detect the current state and history of the structure, even though it could not detect the shear surface of the slope movement. On the other hand, two profiles of electrical tomography were made, one in each studied sector. The profiles were configured with a total length of 189 m, with 64 electrodes and a spacing of 3 m. This allowed investigating up to 35 m depth. This penetration capability enabled to detect the

  18. Electricity

    CERN Document Server

    Basford, Leslie

    2013-01-01

    Electricity Made Simple covers the fundamental principles underlying every aspect of electricity. The book discusses current; resistance including its measurement, Kirchhoff's laws, and resistors; electroheat, electromagnetics and electrochemistry; and the motor and generator effects of electromagnetic forces. The text also describes alternating current, circuits and inductors, alternating current circuits, and a.c. generators and motors. Other methods of generating electromagnetic forces are also considered. The book is useful for electrical engineering students.

  19. Experimental root mean square charge radii, isotope shifts, ground state magnetic dipole and electric quadrupole moments of 1≤A≤ 239 nuclei

    International Nuclear Information System (INIS)

    Antony, M.S.; Britz, J.

    1986-01-01

    A compilation of experimental root-mean square radii, isotope shifts, ground-state magnetic dipole and electric quadrupole moments of nuclei 1≤A≤239 is presented. Shell, sub-subshell closures and changes in nuclear deformations discernible from data are displayed graphically. The nuclear charge distribution, for 1≤A≤ 239 nuclei deduced from Coulomb displacement energies is shown for comparison

  20. Invariant protection of high-voltage electric motors of technological complexes at industrial enterprises at partial single-phase ground faults

    Science.gov (United States)

    Abramovich, B. N.; Sychev, Yu A.; Pelenev, D. N.

    2018-03-01

    Development results of invariant protection of high-voltage motors at incomplete single-phase ground faults are observed in the article. It is established that current protections have low action selectivity because of an inadmissible decrease in entrance signals during the shirt circuit occurrence in the place of transient resistance. The structural functional scheme and an algorithm of protective actions where correction of automatic zero sequence currents signals of the protected accessions implemented according to the level of incompleteness of ground faults are developed. It is revealed that automatic correction of zero sequence currents allows one to provide the invariance of sensitivity factor for protection under the variation conditions of a transient resistance in the place of damage. Application of invariant protection allows one to minimize damages in 6-10 kV electrical installations of industrial enterprises for a cause of infringement of consumers’ power supply and their system breakdown due to timely localization of emergency of ground faults modes.

  1. Joint application of ground penetrating radar and electrical resistivity measurements for characterization of subsurface stratigraphy in Southwestern Nigeria

    International Nuclear Information System (INIS)

    Adepelumi, A A; Fayemi, O

    2012-01-01

    The frequent building collapses in Nigeria have been attributed to a lack of pre-construction investigations, which assist engineers in obtaining in situ geotechnical information. Further, the structural subsurface settings are often ignored or investigation is haphazardly carried out. To address this issue and demonstrate the importance of such a survey, a combination of ground penetrating radar (GPR) and vertical electrical sounding (VES) data were acquired in a part of Southwestern Nigeria. A 200 MHz antenna was used for the data acquisition along four traverses. The data were subjected to standard GPR processing techniques, and attribute analysis such as instantaneous frequency, amplitude and phase. Also, for comparative and engineering characterization purposes, longitudinal conductance and coefficient of anisotropy were computed from the VES results and used for determining the competency of the bedrocks. From the GPR results, it was observed that the mapped subsurface is characterized as erosional truncated at a low angle, which is southerly dipping and includes tangential reflections. Further, stratified rocks dipping at an angle of 32° occur between 1.0 and 4.5 m depth in all of the GPR sections; these strata were truncated by topsoil at shallow depths. Also, some of the sections depict ancient channel structures that have a dimension of 70 m × 40 m. The resistivity data suggest that the study area is characterized by four distinct geoelectric sequences. These comprise topsoil which is composed of clay-like sand to lateritic clay whose thickness ranges between 0.25 and 8.12 m, weathered bedrock with a thickness between 3.84 and 12.61 m, stratified bedrock with a thickness between 0.33 and 7.51 m, and fresh bedrock. These results reveal a complex subsurface geology and this characterizes the study area. The area has low to moderate longitudinal conductance and coefficient of anisotropy values, which suggest that incompetent to semi-competent bedrock

  2. Lightning rod ionizing natural ionca - Ionic electrode active trimetallictriac of grounding - Definitive and total solution against 'blackouts' and electrical faults generated by atmospheric charges (lightning)

    Energy Technology Data Exchange (ETDEWEB)

    Cabareda, Luis

    2010-09-15

    The Natural Ionizing System of Electrical Protection conformed by: Lightning Rod Ionizing Natural Ionca and Ionic Electrode Active Trimetallic Triac of Grounding offers Total Protection, Maximum Security and Zero Risk to Clinics, Hospitals, Integral Diagnostic Center, avoiding ''the burning'' of Electronics Cards; Refineries, Tanks and Stations of Fuel Provision; Electrical Substations, Towers and Transmission Lines with transformer protection, motors, elevators, A/C, mechanicals stairs, portable and cooling equipment, electrical plants, others. This New High Technology is the solution to the paradigm of Benjamin Franklin and it's the mechanism to end the 'Blackouts' that produces so many damages and losses throughout the world.

  3. Design of a grounding network in electrical substations. Materials and formulas the most used; Diseno de redes de tierra en subestaciones electricas. Materiales y formulas mas utilizadas

    Energy Technology Data Exchange (ETDEWEB)

    Raull Martin, J. [Facultad de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2000-09-01

    The purpose of this paper is to present a summarized version of the different types of construction of grounding systems, as well as their materials and formulas, which are necessary and useful for the design and building of a grounding network for medium to high voltage facilities. A description is also made of how to determine the electrical resistivity of subsoil layers with different physical characteristics. Several illustrative examples are also solved in the paper. [Spanish] El proposito de este articulo es presentar de manera resumida los diferentes tipos de construccion de los sistemas de tierra, asi como sus materiales y formulas, los cuales son necesarios y utiles para el diseno y edificacion de una red de tierra para instalaciones de mediana y alta tension. Se describe tambien la obtencion de las diferentes resistividades que presenta los terrenos con diversas caracteristicas fisicas. Asimismo, se solucionan ejercicios ilustrativos a lo largo del articulo.

  4. Methodology for evaluating the grounding system in electrical substations; Metodologia para la evaluacion del sistema de puesta a tierra en subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Torrelles Rivas, L.F [Universidad Nacional Experimental Politecnica: Antonio Jose de Sucre (UNEXPO), Guayana, Bolivar (Venezuela)]. E-mail: torrellesluis@gmail.com; Alvarez, P. [Petroleos de Venezuela S.A (PDVSA), Maturin, Monagas (Venezuela)]. E-mail: alvarezph@pdvsa.com

    2013-03-15

    The present work proposes a methodology for evaluating grounding systems in electrical substations from medium and high voltage, in order to diagnose the state of the elements of the grounding system and the corresponding electrical variables. The assessment methodology developed includes a visual inspection phase to the elements of the substation. Then, by performing measurements and data analysis, the electrical continuity between the components of the substation and the mesh ground is verified, the soil resistivity and resistance of the mesh. Also included in the methodology the calculation of the step and touch voltage of the substation, based on the criteria of the International IEEE standards. We study the case of the 115 kV Pirital Substation belonging to PDVSA Oriente Transmission Network. [Spanish] En el presente trabajo se plantea una metodologia para la evaluacion de sistemas de puesta a tierra en subestaciones electricas de media y alta tension, con la finalidad de diagnosticar el estado de los elementos que conforman dicho sistema y las variables electricas correspondientes. La metodologia de evaluacion desarrollada incluye una fase de inspeccion visual de los elementos que conforman la subestacion. Luego, mediante la ejecucion de mediciones y analisis de datos, se verifica la continuidad electrica entre los componentes de la subestacion y la malla de puesta a tierra, la resistividad del suelo y resistencia de la malla. Se incluye tambien en la metodologia el calculo de las tensiones de paso y de toque de la subestacion, segun lo fundamentado en los criterios de los estandares Internacionales IEEE. Se estudia el caso de la Subestacion Pirital 115 kV perteneciente a la Red de Transmision de PDVSA Oriente.

  5. Electricity

    International Nuclear Information System (INIS)

    Tombs, F.

    1983-01-01

    The subject is discussed, with particular reference to the electricity industry in the United Kingdom, under the headings; importance and scope of the industry's work; future fuel supplies (estimated indigenous fossil fuels reserves); outlook for UK energy supplies; problems of future generating capacity and fuel mix (energy policy; construction programme; economics and pricing; contribution of nuclear power - thermal and fast reactors; problems of conversion of oil-burning to coal-burning plant). (U.K.)

  6. Comparative regional-scale soil salinity assessment with near-ground apparent electrical conductivity and remote sensing canopy reflectance

    Science.gov (United States)

    Soil salinity is recognized worldwide as a major threat to agriculture, particularly in arid and semi-arid regions. Farmers and decision makers need updated and accurate maps of salinity in agronomically and environmentally relevant ranges (i.e., <20 dS m/1, when salinity is measured as electrical...

  7. Ground-truthing electrical resistivity methods in support of submarine groundwater discharge studies: Examples from Hawaii, Washington, and California

    Science.gov (United States)

    Johnson, Cordell; Swarzenski, Peter W.; Richardson, Christina M.; Smith, Christopher G.; Kroeger, Kevin D.; Ganguli, Priya M.

    2015-01-01

    Submarine groundwater discharge (SGD) is an important conduit that links terrestrial and marine environments. SGD conveys both water and water-borne constituents into coastal waters, where these inflows may impact near-shore ecosystem health and sustainability. Multichannel electrical resistivity techniques have proven to be a powerful tool to examine scales and dynamics of SGD and SGD forcings. However, there are uncertainties both in data aquisition and data processing that must be addressed to maximize the effectiveness of this tool in estuarine or marine environments. These issues most often relate to discerning subtle nuances in the flow of electricity through variably saturated media that can also be highly conductive (i.e., seawater).

  8. Effects of effluents from a coal-fired, electric-generating powerplant on local ground water near Hayden, Colorado

    Science.gov (United States)

    Ellis, S.R.; Mann, P.G.

    1981-01-01

    Data were collected at the Hayden, Colo., powerplant for about a year during 1978-79 to monitor the effects of effluent and raw-water storage ponds on the local ground water, Sage Creek, and the Yampa River. The concentration of boron in wells downgradient from the effluent ponds indicated that the ponds were leaking, increasing the average boron concentrations in the ground water to a level in excess of the standards for agricultural use of water. Water from seeps, probably the best indicators of downgradient water quality, had average concentrations of boron two times that of the Colorado Department of Health (1977) standard for agricultural use of water. Chemical analyses of water from wells and the discharge weir downgradient from the raw-water storage ponds indicated these ponds are leaking. The effect of this leakage is that the water in wells downgradient from these ponds has a lower specific conductance and a lower boron concentration than the water in wells downgradient from the effluent ponds. The concentration of trace elements in the water from the wells and the discharge weir generally declined during the study, probably because the ground water was recovering from the effects of a plume from the raw-water pond previously used for fly-ash disposal. The effluents from the Hayden powerplant lowered the specific conductance and the iron and manganese concentrations, increased the concentration of boron, and had little or no effect on the selenium concentration in Sage Creek. Sage Creek had no discernible effect on the Yampa River because the volume of water in the Yampa River was so much greater. The effluents from the powerplant also had no discernible effect on the Yampa River. (USGS)

  9. 46 CFR 111.05-13 - Grounding connection.

    Science.gov (United States)

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Equipment Ground, Ground Detection, and Grounded Systems § 111.05-13 Grounding... power sources operating in parallel in the system. ...

  10. Ab initio potential energy surface, electric-dipole moment, polarizability tensor, and theoretical rovibrational spectra in the electronic ground state of {sup 14}NH{sub 3}{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Yurchenko, Sergei N. [Technische Universitaet Dresden, Institut fuer Physikalische Chemie und Elektrochemie, D-01062 Dresden (Germany); Thiel, Walter [Max-Planck-Institut fuer Kohlenforschung, Kaiser-Wilhelm-Platz 1, D-45470 Muelheim an der Ruhr (Germany); Carvajal, Miguel [Departamento de Fisica Aplicada, Facultad de Ciencias Experimentales, Avenida de las Fuerzas Armadas s/n, Universidad de Huelva, E-21071 Huelva (Spain); Jensen, Per [Theoretische Chemie, Bergische Universitaet, D-42097 Wuppertal (Germany)], E-mail: jensen@uni-wuppertal.de

    2008-05-04

    We report the calculation of a six-dimensional CCSD(T)/aug-cc-pVQZ potential energy surface for the electronic ground state of NH{sub 3}{sup +} together with the corresponding CCSD(T)/aug-cc-pVTZ dipole moment and polarizability surface of {sup 14}NH{sub 3}{sup +}. These electronic properties have been computed on a large grid of molecular geometries. A number of newly calculated band centers are presented along with the associated electric-dipole transition moments. We further report the first calculation of vibrational matrix elements of the polarizability tensor components for {sup 14}NH{sub 3}{sup +}; these matrix elements determine the intensities of Raman transitions. In addition, the rovibrational absorption spectra of the {nu}{sub 2}, {nu}{sub 3}, {nu}{sub 4}, 2{nu}{sub 2}-{nu}{sub 2}, and {nu}{sub 2}+{nu}{sub 3}-{nu}{sub 2} bands have been simulated.

  11. Measurement of geo electric and radon intensity on determination of potential area for ground water drilling at Lebeng Barat village, Pasongsongan, East Java

    International Nuclear Information System (INIS)

    I Gde Sukadana

    2013-01-01

    Lebeng Barat village, Pasongsongan sub-district is a village which has insufficient of fresh water, particularly in dry season. This region has a fairly dense population and equitable distribution of the population, therefore a sufficient supply of clean water for consumption and other needs are required. The purpose of study is to find out the ground-water potential zone in determination of exploration drilling points to develop ground-water’s well production. The methods used in this study as follow: Geological/hydrogeological mapping, measurement of radon intensity and geo-electric sounding survey with Schlumberger’s configuration. Exposed rocks within work areas can be classified into 5 (five) rocks unit, namely clay stone with intercalation of limestone unit, inter bedded of calcareous sandstone and limestone unit, mud stone unit and limestone-clay stone unit. The potential rock’s layer as aquifer is a layer of calcareous sandstone which has characteristic of pale yellow to brown, medium-coarse grained, sufficient permeability rocks (in the section exposed at the surface) include the limestone unit. Rock aquifers that serve on the bottom are included in inter bedded of calcareous sandstone and limestone unit. Potential points recommended for drilling exploration / production are the point of LBR-29 with the thickness of the aquifer 1 (shallower) 33.86 m and aquifer 2 (deeper) 23.72 m. (author)

  12. Realization of Multi-Stable Ground States in a Nematic Liquid Crystal by Surface and Electric Field Modification

    Science.gov (United States)

    Gwag, Jin Seog; Kim, Young-Ki; Lee, Chang Hoon; Kim, Jae-Hoon

    2015-06-01

    Owing to the significant price drop of liquid crystal displays (LCDs) and the efforts to save natural resources, LCDs are even replacing paper to display static images such as price tags and advertising boards. Because of a growing market demand on such devices, the LCD that can be of numerous surface alignments of directors as its ground state, the so-called multi-stable LCD, comes into the limelight due to the great potential for low power consumption. However, the multi-stable LCD with industrial feasibility has not yet been successfully performed. In this paper, we propose a simple and novel configuration for the multi-stable LCD. We demonstrate experimentally and theoretically that a battery of stable surface alignments can be achieved by the field-induced surface dragging effect on an aligning layer with a weak surface anchoring. The simplicity and stability of the proposed system suggest that it is suitable for the multi-stable LCDs to display static images with low power consumption and thus opens applications in various fields.

  13. Soil bulk electrical resistivity and forage ground cover: nonlinear models in an alfalfa (Medicago sativa L. case study

    Directory of Open Access Journals (Sweden)

    Roberta Rossi

    2015-12-01

    Full Text Available Alfalfa is a highly productive and fertility-building forage crop; its performance, can be highly variable as influenced by within-field soil spatial variability. Characterising the relations between soil and forage- variation is important for optimal management. The aim of this work was to model the relationship between soil electrical resistivity (ER and plant productivity in an alfalfa (Medicago sativa L. field in Southern Italy. ER mapping was accomplished by a multi-depth automatic resistivity profiler. Plant productivity was assessed through normalised difference vegetation index (NDVI at 2 dates. A non-linear relationship between NDVI and deep soil ER was modelled within the framework of generalised additive models. The best model explained 70% of the total variability. Soil profiles at six locations selected along a gradient of ER showed differences related to texture (ranging from clay to sandy-clay loam, gravel content (0 to 55% and to the presence of a petrocalcic horizon. Our results prove that multi-depth ER can be used to localise permanent soil features that drive plant productivity.

  14. Electrical resistivity imaging (ERI) and ground-penetrating radar (GPR) survey at the Giribaile site (upper Guadalquivir valley; southern Spain)

    Science.gov (United States)

    Martínez, J.; Rey, J.; Gutiérrez, L. M.; Novo, A.; Ortiz, A. J.; Alejo, M.; Galdón, J. M.

    2015-12-01

    The Giribaile archaeological site is one of the most important Iberian enclaves of the Alto Guadalquivir (Southern Spain). However, to date, only minimal excavation work has been performed at the site. Evaluation requires a preliminary, non-destructive general analysis to determine high-interest areas. This stage required a geophysical survey. Specifically, a 100 m2 grid was selected, where an initial campaign of nine electrical resistivity imaging (ERI) profiles was performed, where each profile was 111 m in length; these profiles were previously located using a detailed topographical survey. A total of 112 electrodes were used for each profile, spaced at 1 m apart with a Wenner-Schlumberger configuration. Secondly, 201 GPR profiles were created using a 500 MHz antenna. The 100 m long profiles were spaced 0.5 m apart and parallel to one another. The present research analyses the efficiency of each of these geophysical tools in supporting archaeological research. Using these methodologies, the position, morphology, and depth of different buried structures can be determined. 3D interpretation of the geophysical survey in 100 × 100 m grid allowed to differentiate structures square and rectangular, interesting buildings in a semicircle (interpreted as ovens) plus delineate different streets. From the geophysical survey follows the Carthaginian presence inside this ancient Iberian enclave.

  15. Electrical Methods: Resistivity Methods

    Science.gov (United States)

    Surface electrical resistivity surveying is based on the principle that the distribution of electrical potential in the ground around a current-carrying electrode depends on the electrical resistivities and distribution of the surrounding soils and rocks.

  16. A de-noising algorithm based on wavelet threshold-exponential adaptive window width-fitting for ground electrical source airborne transient electromagnetic signal

    Science.gov (United States)

    Ji, Yanju; Li, Dongsheng; Yu, Mingmei; Wang, Yuan; Wu, Qiong; Lin, Jun

    2016-05-01

    The ground electrical source airborne transient electromagnetic system (GREATEM) on an unmanned aircraft enjoys considerable prospecting depth, lateral resolution and detection efficiency, etc. In recent years it has become an important technical means of rapid resources exploration. However, GREATEM data are extremely vulnerable to stationary white noise and non-stationary electromagnetic noise (sferics noise, aircraft engine noise and other human electromagnetic noises). These noises will cause degradation of the imaging quality for data interpretation. Based on the characteristics of the GREATEM data and major noises, we propose a de-noising algorithm utilizing wavelet threshold method and exponential adaptive window width-fitting. Firstly, the white noise is filtered in the measured data using the wavelet threshold method. Then, the data are segmented using data window whose step length is even logarithmic intervals. The data polluted by electromagnetic noise are identified within each window based on the discriminating principle of energy detection, and the attenuation characteristics of the data slope are extracted. Eventually, an exponential fitting algorithm is adopted to fit the attenuation curve of each window, and the data polluted by non-stationary electromagnetic noise are replaced with their fitting results. Thus the non-stationary electromagnetic noise can be effectively removed. The proposed algorithm is verified by the synthetic and real GREATEM signals. The results show that in GREATEM signal, stationary white noise and non-stationary electromagnetic noise can be effectively filtered using the wavelet threshold-exponential adaptive window width-fitting algorithm, which enhances the imaging quality.

  17. Electrically floating, near vertical incidence, skywave antenna

    Science.gov (United States)

    Anderson, Allen A.; Kaser, Timothy G.; Tremblay, Paul A.; Mays, Belva L.

    2014-07-08

    An Electrically Floating, Near Vertical Incidence, Skywave (NVIS) Antenna comprising an antenna element, a floating ground element, and a grounding element. At least part of said floating ground element is positioned between said antenna element and said grounding element. The antenna is separated from the floating ground element and the grounding element by one or more electrical insulators. The floating ground element is separated from said antenna and said grounding element by one or more electrical insulators.

  18. Electrical Resistivity Tomography and Ground Penetrating Radar for locating buried petrified wood sites: a case study in the natural monument of the Petrified Forest of Evros, Greece

    Science.gov (United States)

    Vargemezis, George; Diamanti, Nectaria; Tsourlos, Panagiotis; Fikos, Ilias

    2014-05-01

    A geophysical survey was carried out in the Petrified Forest of Evros, the northernmost regional unit of Greece. This collection of petrified wood has an age of approximately 35 million years and it is the oldest in Greece (i.e., older than the well-known Petrified Forest of Lesvos island located in the North Aegean Sea and which is possibly the largest of the petrified forests worldwide). Protection, development and maintenance projects still need to be carried out at the area despite all fears regarding the forest's fate since many petrified logs remain exposed both in weather conditions - leading to erosion - and to the public. This survey was conducted as part of a more extensive framework regarding the development and protection of this natural monument. Geophysical surveying has been chosen as a non-destructive investigation method since the area of application is both a natural ecosystem and part of cultural heritage. Along with electrical resistivity tomography (ERT), ground penetrating radar (GPR) surveys have been carried out for investigating possible locations of buried fossilized tree trunks. The geoelectrical sections derived from ERT data in combination with the GPR profiles provided a broad view of the subsurface. Two and three dimensional subsurface geophysical images of the surveyed area have been constructed, pointing out probable locations of petrified logs. Regarding ERT, petrified trunks have been detected as high resistive bodies, while lower resistivity values were more related to the surrounding geological materials. GPR surveying has also indicated buried petrified log locations. As these two geophysical methods are affected in different ways by the subsurface conditions, the combined use of both techniques enhanced our ability to produce more reliable interpretations of the subsurface. After the completion of the geophysical investigations of this first stage, petrified trunks were revealed after a subsequent excavation at indicated

  19. Latitudinal Distributions of Auroral Zone Electric Fields and Ground Magnetic Perturbations and Their Response to Variations in the Interplanetary Magnetic Field

    International Nuclear Information System (INIS)

    Horwitz, J.L.; Doupnik, J.R.; Banks, P.M.; Kamide, Y.; Akasofu, S.

    1978-01-01

    Chatanika observations of latitudinal distributions of convection electric fields (E 1 ) are compared with isointensity ΔH contours in latitude and time from the Alaskan magnetometer chain and with the north-south component of the interplanetary magnetic field (IMF B/sub z/m) from Imp-J. As expected, northward electric fields were generally observed within latitude and time regions where ΔH was positive, while southward electric fields were observed within negative ΔH regions. However, correlation between the magnitudes of the electric fields and of the ΔH perturbations was not strong, owing to variability in ionospheric conductivities produced by precipitation and solar illumination. In the midnight sector the northward-to-southward transition in the electric field and positive-to-negative ΔH transition were roughly collocated (to within 1 hour in local time) as signatures of the Harang discontinuity. The most important findings are that (1) southward (northward) IMF B/sub z/m transitions caused rapid equatorward (poleward) shifts of the electric field and ΔH patterns and (2) southward IMF B/sub z/ transitions, magnetospheric substorms, and local time transitions of the Harang discontinuity can all lead to northward-to-southward transitions of the electric field in the midnight sector. Due to the interlaced phasing of each of these three causal mechanisms a highly complex temporal pattern of electric fields results

  20. 33 CFR 183.415 - Grounding.

    Science.gov (United States)

    2010-07-01

    ... SAFETY BOATS AND ASSOCIATED EQUIPMENT Electrical Systems Manufacturer Requirements § 183.415 Grounding. If a boat has more than one gasoline engine, grounded cranking motor circuits must be connected to...

  1. Joint two-dimensional observations of ground magnetic and ionospheric electric fields associated with auroral zone currents 1. Three-dimensional current flows associated with a substorm-intensified eastward electrojet

    International Nuclear Information System (INIS)

    Baumjohann, W.; Untiedt, J.; Greenwald, R.A.

    1980-01-01

    Two-dimensional distributions of ground magnetic and ionospheric electric fields in the evening sector auroral oval have been simultaneously observed by the Scandinavian Magnetometer Array and the Scandinavian Twin Auroral Radar Experiment (Stare) radars, respectively, on February 15, 1977. They were associated with varying, substorm-intensified, eastward electrojet current systems of the western, middle, and eastern segment of the eastward electrojet. We conclude that the substorm-intensified eastward electroject was a nearly pure Hall current driven by northward electric fields. The observed eastward increase of the current in the western segment of the electrojet was due to a gradual enhancement of the Hall conductivity. Here, the electrojet was fed by a broad sheet of net downward field-aligned current. During one period, the eastern-terminating part of the eastward electrojet diverged up the field lines in a rather local area because of a strong longitudinal decrease in the northward-directed electric field. On another occasion, it diverged northward within the ionosphere and joined the westward-flowing current because of a rotation of the northward electric field with increasing latitude through west- to southward. These two observed mechanisms of current divergence in the region where eastward and westward electrojects coexist may shed some new light on the controversy over the existence of upward field-aligned current flow in the Harang discontinuity

  2. Imaging the Mariánské Lázně Fault (Czech Republic) by 3-D ground-penetrating radar and electric resistivity tomography

    Czech Academy of Sciences Publication Activity Database

    Fischer, Tomáš; Štěpančíková, Petra; Karousová, M.; Tábořík, P.; Flechsig, C.; Gaballah, M.

    2012-01-01

    Roč. 56, č. 4 (2012), s. 1019-1036 ISSN 0039-3169 R&D Projects: GA AV ČR IAA300120905 Institutional research plan: CEZ:AV0Z30120515; CEZ:AV0Z30460519 Keywords : fault tectonics * resistivity tomography * ground penetrating radar Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 0.975, year: 2012

  3. Grounded theory.

    Science.gov (United States)

    Harris, Tina

    2015-04-29

    Grounded theory is a popular research approach in health care and the social sciences. This article provides a description of grounded theory methodology and its key components, using examples from published studies to demonstrate practical application. It aims to demystify grounded theory for novice nurse researchers, by explaining what it is, when to use it, why they would want to use it and how to use it. It should enable nurse researchers to decide if grounded theory is an appropriate approach for their research, and to determine the quality of any grounded theory research they read.

  4. Application of vertical electrical sounding combined with induced polarization method in ground water exploration; IP koka wo koryoshita hiteikoho suichoku tansa no chikasui chosa eno tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M; Sakurada, H [Sumiko Consultants Co. Ltd., Tokyo (Japan); Suzuki, T [Hokkaido Development Bureau, Hokkaido Development Agency, Sapporo (Japan)

    1996-10-01

    For ground water exploration using vertical Schlumberger exploration method, measurement and analysis combined with induced polarization (IP) effect were conducted as trial. For the Schlumberger method, potential is measured at the center between potential electrodes during flow of dc current between current electrodes. In the case of vertical exploration, measurements are repeated with fixed potential electrodes by extending the distance between current electrodes. Ground water exploration was conducted using this method at Otaki village, Hokkaido. Geology of surveyed plateau consists of a basement of Pliocene tuffs and Quaternary Pleistocene sediments covering on the surface. For the results of analysis, four to seven beds were detected from the resistivity. The depth up to the lowest bed was between 25 and 85 m, the resistivity of each bed was between 9 and 8,000 ohm{times}m, and the polarizability was between 1 and 15 mV/V. Among these resistivity zones, it was judged that zones satisfying following three conditions correspond to coarse grain sediments saturated with ground water, and can be expected as aquifers; having resistivity ranging between 100 and 1,000 ohm{times}m, polarizability higher than 10 mV/V, and relatively large thickness. 11 refs., 6 figs.

  5. An overview of a highly versatile forward and stable inverse algorithm for airborne, ground-based and borehole electromagnetic and electric data

    DEFF Research Database (Denmark)

    Auken, Esben; Christiansen, Anders Vest; Kirkegaard, Casper

    2015-01-01

    . This engine includes support for mixed data types, arbitrary model parameter constraints, integration of prior information and calculation of both model parameter sensitivity analysis and depth of investigation. We present a review of our implementation and methodology and show four different examples......We present an overview of a mature, robust and general algorithm providing a single framework for the inversion of most electromagnetic and electrical data types and instrument geometries. The implementation mainly uses a 1D earth formulation for electromagnetics and magnetic resonance sounding...... types of data. Our implementation is modular, meaning that the bulk of the algorithm is independent of data type, making it easy to add support for new types. Having implemented forward response routines and file I/O for a given data type provides access to a robust and general inversion engine...

  6. Grounding for safety

    Energy Technology Data Exchange (ETDEWEB)

    Prud' homme, P. [Hydro-Quebec, Montreal, PQ (Canada). TransEnergie Div.

    2006-07-01

    The importance of providing electrical grounds as a safety issue in the design of power transmission lines was discussed. Power transmission lines extend over several thousands of kilometers crossing various environments, including communities where electric utilities encourage the use of transmission rights-of-way passages for uses such as bicycle paths. In recent years, many new residential communities have been built at the border of power transmission rights-of-ways or substations. In view of this emerging trend, and the fact that internal statistics indicate that lightning strikes are responsible of about 50 to 60 per cent of transmission line faults, electric utilities are obligated to verify if their installations are safe. Hydro-Quebec TransEnergie's view on this subject was presented along with a review of international standards to determine if limits for touch voltage, step voltage and transferred potential close to transmission lines have been established by the international community. A variety of mitigation measures to control the increase in ground potential in the event of electrical faults were also proposed. tabs., figs.

  7. Electrochemical stabilization of clayey ground

    Science.gov (United States)

    Rzhanitzin, B.A.; Sokoloff, V.P.

    1947-01-01

    Recently developed new methods of stabilization of weak grounds (e.g. the silicate treatment) are based on injection of chemical solutions into the ground. Such methods are applicable accordingly only to the kinds of ground that have the coefficient of filtration higher than 2 meters per 24 hours and permit penetration of the chemical solutions under pressure. This limit, however, as it is shown by our experience in construction, excludes a numerous and an important class of grounds, stabilization of which is indispensable in many instances. For example, digging of trenches and pits in clayey, silty, or sandy ground shows that all these types act like typical "floaters" (sluds? -S) in the presence of the ground water pressure. There were several instances in the canalization of the city of Moskow where the laying of trenches below the ground water level has led to extreme difficulties with clayey and silty ground. Similar examples could be cited in mining, engineering hydrology, and railroad construction. For these reasons, the development of methods of stabilizing such difficult types of ground has become an urgent problem of our day. In 1936, the author began his investigations, at the ground Stabilization Laboratory of VODGEO Institute, with direct electrical current as the means of stabilization of grounds. Experiments had shown that a large number of clayey types, following passage of direct electrical current, undergoes a transformation of its physico-chemical properties. It was established that the (apparent -S) density of the ground is substantially increased in consequence of the application of direct electrical current. The ground loses also its capacity to swell and to soften in water. Later, after a more detailed study of the physico-chemical mechanism of the electrical stabilization, it became possible to develop the method so as to make it applicable to sandy and silty as well as to clayey ground. By this time (1941, S.), the method has already been

  8. Photovoltaic module mounting clip with integral grounding

    Science.gov (United States)

    Lenox, Carl J.

    2010-08-24

    An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

  9. Ground water

    International Nuclear Information System (INIS)

    Osmond, J.K.; Cowart, J.B.

    1982-01-01

    The subject is discussed under the headings: background and theory (introduction; fractionation in the hydrosphere; mobility factors; radioisotope evolution and aquifer classification; aquifer disequilibria and geochemical fronts); case studies (introduction; (a) conservative, and (b) non-conservative, behaviour); ground water dating applications (general requirements; radon and helium; radium isotopes; uranium isotopes). (U.K.)

  10. Ground water

    International Nuclear Information System (INIS)

    Osmond, J.K.; Cowart, J.B.

    1992-01-01

    The great variations in concentrations and activity ratios of 234 U/ 238 U in ground waters and the features causing elemental and isotopic mobility in the hydrosphere are discussed. Fractionation processes and their application to hydrology and other environmental problems such as earthquake, groundwater and aquifer dating are described. (UK)

  11. On LHCb muon MWPC grounding

    CERN Document Server

    Kashchuk, A

    2006-01-01

    My goal is to study how a big MWPC system, in particular the LHCb muon system, can be protected against unstable operation and multiple spurious hits, produced by incorrect or imperfect grounding in the severe EM environment of the LHCb experiment. A mechanism of penetration of parasitic current from the ground loop to the input of the front-end amplifier is discussed. A new model of the detector cell as the electrical bridge is considered. As shown, unbalance of the bridge makes detector to be sensitive to the noise in ground loop. Resonances in ground loop are specified. Tests of multiple-point and single-point grounding conceptions made on mock-up are presented.

  12. Electric rivers

    International Nuclear Information System (INIS)

    McCutcheon, S.

    1992-04-01

    James Bay II, the projected Canadian hydroelectric power plant of gigantic dimensions, is to deliver its electricity to Europe: in the USA, opposition to power imports from James Bay is growing. Its realization means the flooding of an area as big as the Federal Republic of Germany; the native territory and hunting grounds of the Cree indians would be inundated. The interests of the European power industry in the James Bay project and the consequences for Europe are described in an appendix (EQHHPP project, project management Hydro-Quebec and Ludwig Boelkow Foundation, hydrogen production through electrolysis, methods for transporting hydrogen to Hamburg). (orig./HP) [de

  13. Ground Pollution Science

    International Nuclear Information System (INIS)

    Oh, Jong Min; Bae, Jae Geun

    1997-08-01

    This book deals with ground pollution science and soil science, classification of soil and fundamentals, ground pollution and human, ground pollution and organic matter, ground pollution and city environment, environmental problems of the earth and ground pollution, soil pollution and development of geological features of the ground, ground pollution and landfill of waste, case of measurement of ground pollution.

  14. Identifying structural damage with ground penetrating radar

    CSIR Research Space (South Africa)

    Van Schoor, Abraham M

    2008-07-01

    Full Text Available Ground penetrating radar (GPR) and electrical resistance tomography (ERT) surveys were conducted in an urban environment in an attempt to identify the cause of severe structural damage to a historically significant residential property...

  15. Electricity your common sense guide

    CERN Document Server

    Ilich, Nick

    2015-01-01

    At last, a book that explains electricity in a very simple and easy way for everyone to understand. You will learn the basics of electricity, power to your home, receptacles, neutral and grounding, extension cord "Do's" and "Don'ts" and electrical shock.The book ends with safety tips and suggestions for you to stay safe and be shock free.

  16. Communication grounding facility

    International Nuclear Information System (INIS)

    Lee, Gye Seong

    1998-06-01

    It is about communication grounding facility, which is made up twelve chapters. It includes general grounding with purpose, materials thermal insulating material, construction of grounding, super strength grounding method, grounding facility with grounding way and building of insulating, switched grounding with No. 1A and LCR, grounding facility of transmission line, wireless facility grounding, grounding facility in wireless base station, grounding of power facility, grounding low-tenton interior power wire, communication facility of railroad, install of arrester in apartment and house, install of arrester on introduction and earth conductivity and measurement with introduction and grounding resistance.

  17. 'Grounded' Politics

    DEFF Research Database (Denmark)

    Schmidt, Garbi

    2012-01-01

    play within one particular neighbourhood: Nørrebro in the Danish capital, Copenhagen. The article introduces the concept of grounded politics to analyse how groups of Muslim immigrants in Nørrebro use the space, relationships and history of the neighbourhood for identity political statements....... The article further describes how national political debates over the Muslim presence in Denmark affect identity political manifestations within Nørrebro. By using Duncan Bell’s concept of mythscape (Bell, 2003), the article shows how some political actors idealize Nørrebro’s past to contest the present...... ethnic and religious diversity of the neighbourhood and, further, to frame what they see as the deterioration of genuine Danish identity....

  18. Electrical Safety for Non-Electricians

    Science.gov (United States)

    ... handled cement finishing floats • Metal ladders • Raised dump truck beds • Scaffolding But electrical hazards are also at ... must be grounded. Your employer must check all electric systems, including wiring and switches, to be sure ...

  19. Electrical generator

    International Nuclear Information System (INIS)

    Purdy, D.L.

    1976-01-01

    A nuclear heart pacer having a heat-to-electricity converter including a solid-state thermoelectric unit embedded in rubber which is compressed to impress hydrostatic precompression on the unit is described. The converter and the radioactive heat source are enclosed in a container which includes the electrical circuit components for producing and controlling the pulses; the converter and components being embedded in rubber. The portions of the rubber in the converter and in the container through which heat flows between the radioactive primary source and the hot junction and between the cold junction and the wall of the container are of thermally conducting silicone rubber. The 238 Pu primary radioactive source material is encapsuled in a refractory casing of WC-222 (T-222) which in turn is encapsuled in a corrosion-resistant casing of platinum rhodium, a diffusion barrier separating the WC-222 and the Pt--Rh casings. The Pt--Rh casing is in a closed basket of tantalum. The tantalum protects the Pt--Rh from reacting with other materials during cremation of the host, if any. The casings and basket suppress the transmission of hard x rays generated by the alpha particles from the 238 Pu. The outside casing of the pacer is typically of titanium but its surface is covered by an electrically insulating coating, typically epoxy resin, except over a relatively limited area for effective electrical grounding to the body of the host. It is contemplated that the pacer will be inserted in the host with the exposed titanium engaging a non-muscular region of the body

  20. 30 CFR 57.12026 - Grounding transformer and switchgear enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding transformer and switchgear enclosures... NONMETAL MINES Electricity Surface and Underground § 57.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  1. 30 CFR 56.12026 - Grounding transformer and switchgear enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding transformer and switchgear enclosures... MINES Electricity § 56.12026 Grounding transformer and switchgear enclosures. Metal fencing and metal buildings enclosing transformers and switchgear shall be grounded. ...

  2. 49 CFR 229.97 - Grounding fuel tanks.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Grounding fuel tanks. 229.97 Section 229.97 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Equipment § 229.97 Grounding fuel tanks. Fuel tanks and related piping shall be electrically grounded. ...

  3. Device, system and method for a sensing electrical circuit

    Science.gov (United States)

    Vranish, John M. (Inventor)

    2009-01-01

    The invention relates to a driven ground electrical circuit. A driven ground is a current-measuring ground termination to an electrical circuit with the current measured as a vector with amplification. The driven ground module may include an electric potential source V.sub.S driving an electric current through an impedance (load Z) to a driven ground. Voltage from the source V.sub.S excites the minus terminal of an operational amplifier inside the driven ground which, in turn, may react by generating an equal and opposite voltage to drive the net potential to approximately zero (effectively ground). A driven ground may also be a means of passing information via the current passing through one grounded circuit to another electronic circuit as input. It may ground one circuit, amplify the information carried in its current and pass this information on as input to the next circuit.

  4. Recirculating electric air filter

    Science.gov (United States)

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  5. Ground water '89

    International Nuclear Information System (INIS)

    1989-01-01

    The proceedings of the 5th biennial symposium of the Ground Water Division of the Geological Society of South Africa are presented. The theme of the symposium was ground water and mining. Papers were presented on the following topics: ground water resources; ground water contamination; chemical analyses of ground water and mining and its influece on ground water. Separate abstracts were prepared for 5 of the papers presented. The remaining papers were considered outside the subject scope of INIS

  6. Imaging of Ground Ice with Surface-Based Geophysics

    Science.gov (United States)

    2015-10-01

    terrains. Electrical Resistivity Tomography (ERT), in particular, has been effective for imaging ground ice. ERT measures the ability of materials to...13 2.2.1 Electrical resistivity tomography (ERT...Engineer Research and Development Center ERT Electrical Resistivity Tomography GPS Global Positioning System LiDAR Light Detection and Ranging SIPRE

  7. TARDEC Ground Vehicle Robotics: Vehicle Dynamic Characterization and Research

    Science.gov (United States)

    2015-09-01

    subassemblies that would be common on ground vehicles. Powertrain Systems: Gas Powered, Diesel , Turbo Diesel , Gas Turbine, Hybrid: Gas- Electric...PROPULSE (Hybrid Diesel - Electric System with Export Power), Command Zone (integrated vehicle control and diagnostic system), and TerraMax (Unmanned... Diesel -Electric, Series, Parallel. Power Distribution: RWD, FWD, AWD, open diff, LSD, Torsen diff, differential braking (traction control), drive by

  8. Research of grounding capacitive current of neutral non-grounding auxiliary system in nuclear power plants

    International Nuclear Information System (INIS)

    Yang Shan; Liu Li; Huang Xiaojing

    2014-01-01

    In the domestic and abroad standards, the grounding capacitive current limitation in the non-grounding electric auxiliary system is less than 10 A. Limiting capacitive current in the standard aims to speed up the arc extinguishing to reduce the duration of arc over-voltage, but not to prevent the arc producing, The arc over-voltage harm is related to the multiple, frequency and duration of the over-voltage. When the insulation vulnerabilities appear in the equipment, the arc over-voltage may result in insulation vulnerabilities of the electrical equipment breakdown, which leads to multiple, short-circuit accidents. The cable connector, accessory and electromotor winding are all insulation vulnerabilities. Setting the arc suppression coil which can counteract the grounding capacitive current makes the arc vanish quickly. Using the casting bus which remarkably reduces the ground capacitance of the electric transmission line makes the equipment safer. (authors)

  9. Study of electric monopole transitions between the ground state and the first excited O+-state in 40,42,44,48Ca with high resolution inelastic electron scattering

    International Nuclear Information System (INIS)

    Strottman, D.; Graef, H.D.; Feldmeier, H.; Manakos, P.; Richter, A.; Spamer, E.

    1977-11-01

    Monopole transitions from the O + 1 ground states to O + 2 excited states at 3.353 MeV ( 40 Ca), 1.837 MeV ( 42 Ca), 1.884 MeV ( 44 Ca) and 4.272 Mev ( 48 Ca) have been investigated with high resolution inelastic electron scattering (FWHM approximately equal to 30 keV) at low momentum transfer (0.29 fm -1 -1 ). The respective monopole matrix elements are (2.53 +- 0.41) fm 2 , (5.24 +- 0.39) fm 2 , (5.45 +- 0.41) fm 2 and (2.28 +- 0.49) fm 2 . These results are used together with known ground state charge radii and the average number of holes in the sd-shell in the ground state to estimate the number of particle-hole excitations in the wavefunctions of th excited O + states. (orig.) [de

  10. Seven methods to measure ground moisture

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The correct irrigation methods are of great importance to the deciduous fruit grower. The article discusses seven methods for the measuring of ground humidity. These methods are based on gravimetry, electric resistance, gamma attenuation, neutron humidity measurement, tensiometers and a study of the correlation between ground humidity and water evaporation. At this stage, the last technique is regarded as the most practicle method. Neutron moisture gages might be used if adhered to the regulations of NUCOR

  11. A Study on the Improvement Effect and Field Applicability of the Deep Soft Ground by Ground Heating Method

    Directory of Open Access Journals (Sweden)

    Mincheol Park

    2018-05-01

    Full Text Available The soft ground in coastal areas should be treated when it needs to be used for the sustainably developed of urban or industrial complex constructions. The ground heating method for soft ground improvement was applied in Eastern Europe in the 1960s, but it was not widely used due to economic and environmental problems. The author developed a device for improving soft ground using an electric heating pipe. This paper investigates the improvement effect and field application of deep soft ground by the ground heating method using the electric heating pipe. Ground heating increases the temperature of the deep soft ground and increases the tip resistance of the static electronic piezo-cone penetration test. Additionally, the pressure of the pore water decreases because the pore water is evaporated due to the ground heating. As a result of the experiment, it was verified that there was an improvement in the effect of deep soft ground by the ground heating method. With ground heating for 96 h, the tip resistance was increased by 61% at a point 0.35 m horizontally away from the electric heat pipe, 22% at 0.97 m, and 2% at 1.31 m. As a result of the field test, it was found that there were no problems in the power supply of the diesel generator and the control panel. It was easy to install the electric heating pipes in the deep soft ground. However, due to boring, the ground was disturbed and water vapor was discharged through this gap. To minimize the discharge of water vapor, it is necessary to drive the electric heating pipe.

  12. Ground water and energy

    Energy Technology Data Exchange (ETDEWEB)

    1980-11-01

    This national workshop on ground water and energy was conceived by the US Department of Energy's Office of Environmental Assessments. Generally, OEA needed to know what data are available on ground water, what information is still needed, and how DOE can best utilize what has already been learned. The workshop focussed on three areas: (1) ground water supply; (2) conflicts and barriers to ground water use; and (3) alternatives or solutions to the various issues relating to ground water. (ACR)

  13. COMPARATIVE ANALYSIS OF GROUNDING RESISTANCE VALUE IN SOIL AND SEPTICTANK

    Directory of Open Access Journals (Sweden)

    Abdul Syakur

    2012-02-01

    Full Text Available The aim of grounding system to protect of electrical equipment and instrumentation system and peopletogether. The lightning stroke near the strucutre of building can damage of equipment and instrumentationsystem. Therefore, it is very important to protect theese electrical and electronic equipment from lightningstrike uses lightning protection system and grounding system.This paper presents kind of grounding system at type of soil and place. The measurement of groundingresistance in soil and septictank have done. Types of soil for grounding resistance measuring aremarshland, clay and rockland.The measurement results of grounding resistance show that value of grounding resistance depend ondeepness of electrode and kind of soil and septictank. Grounding resistance value in septictank is morelower than soil.

  14. Electric power generation

    International Nuclear Information System (INIS)

    Pinske, J.D.

    1981-01-01

    Apart from discussing some principles of power industry the present text deals with the different ways of electric power generation. Both the conventional methods of energy conversion in heating and water power stations and the facilities for utilizing regenerative energy sources (sun, wind, ground heat, tidal power) are considered. The script represents the essentials of the lecture of the same name which is offered to the students of the special subject 'electric power engineering' at the Fachhochschule Hamburg. It does not require any special preliminary knowledge except for the general principles of electrical engineering. It is addressing students of electrical engineering who have passed their preliminary examination at technical colleges and universities. Moreover, it shall also be of use for engineers who want to obtain a quick survey of the structure and the operating characteristics of the extremely different technical methods of power generation. (orig.) [de

  15. Electricity Theory

    International Nuclear Information System (INIS)

    Gong, Ha Soung

    2006-12-01

    The text book composed of five parts, which are summary of this book, arrangement of electricity theory including electricity nad magnetism, a direct current, and alternating current. It has two dictionary electricity terms for a synonym. The last is an appendix. It is for preparing for test of officer, electricity engineer and fire fighting engineer.

  16. Electrical, Electronic, and Electromechanical (EEE) Parts Management and Control Requirements for Space Flight Hardware and Critical Ground Support Equipment...aka... The NASA EEE Parts Standard, NASA-STD 8739.10

    Science.gov (United States)

    Majewicz, Peter; Sampson, Michael

    2016-01-01

    Describes development and content of a new NASA Standard for Electrical Electronic and Electromechanical (EEE) parts. This Standard reflects current practices, instead of changing them. Most NASA Centers utilize local documents, but there is minimal consistency across the Agency. A gap analysis clearly shows the differences that exist among the different centers and with respect to the NASA Parts Policy. Once approved, the new standard can be referenced in contracts and agreements with organizations outside of NASA.

  17. The ground based plan

    International Nuclear Information System (INIS)

    1989-01-01

    The paper presents a report of ''The Ground Based Plan'' of the United Kingdom Science and Engineering Research Council. The ground based plan is a plan for research in astronomy and planetary science by ground based techniques. The contents of the report contains a description of:- the scientific objectives and technical requirements (the basis for the Plan), the present organisation and funding for the ground based programme, the Plan, the main scientific features and the further objectives of the Plan. (U.K.)

  18. Constructivist Grounded Theory?

    Directory of Open Access Journals (Sweden)

    Barney G. Glaser, PhD, Hon. PhD

    2012-06-01

    Full Text Available AbstractI refer to and use as scholarly inspiration Charmaz’s excellent article on constructivist grounded theory as a tool of getting to the fundamental issues on why grounded theory is not constructivist. I show that constructivist data, if it exists at all, is a very, very small part of the data that grounded theory uses.

  19. Communication, concepts and grounding

    NARCIS (Netherlands)

    van der Velde, Frank; van der Velde, F.

    2015-01-01

    This article discusses the relation between communication and conceptual grounding. In the brain, neurons, circuits and brain areas are involved in the representation of a concept, grounding it in perception and action. In terms of grounding we can distinguish between communication within the brain

  20. Geological and Electrical Resistivity Sounding of Olokonla Area in ...

    African Journals Online (AJOL)

    Akorede

    form prefential pathways for ground water. Three vertical electrical ... investigation techniques which use the electrical properties of ... Figure 1: Geological Map of Nigeria Showing the Study Area ... expected to assume a circular shape.

  1. Grounding, Shielding and Power Distribution for the LHCb Silicon Tracking

    CERN Document Server

    Bauer, C; Frei, R; Straumann, U; Vázquez, P; Vollhardt, A

    2005-01-01

    This note lists the relevant items for power and grounding, it explains the sensitive detector input signal circuits and describes the grounding, power distribution and line filtering measures applied to each of the electrical units of the LHCb silicon tracking system. This note deals with both silicon sub-projects, the Inner Tracker (IT) and the Trigger Tracker (TT).

  2. Rigour and grounded theory.

    Science.gov (United States)

    Cooney, Adeline

    2011-01-01

    This paper explores ways to enhance and demonstrate rigour in a grounded theory study. Grounded theory is sometimes criticised for a lack of rigour. Beck (1993) identified credibility, auditability and fittingness as the main standards of rigour for qualitative research methods. These criteria were evaluated for applicability to a Straussian grounded theory study and expanded or refocused where necessary. The author uses a Straussian grounded theory study (Cooney, In press) to examine how the revised criteria can be applied when conducting a grounded theory study. Strauss and Corbin (1998b) criteria for judging the adequacy of a grounded theory were examined in the context of the wider literature examining rigour in qualitative research studies in general and grounded theory studies in particular. A literature search for 'rigour' and 'grounded theory' was carried out to support this analysis. Criteria are suggested for enhancing and demonstrating the rigour of a Straussian grounded theory study. These include: cross-checking emerging concepts against participants' meanings, asking experts if the theory 'fit' their experiences, and recording detailed memos outlining all analytical and sampling decisions. IMPLICATIONS FOR RESEARCH PRACTICE: The criteria identified have been expressed as questions to enable novice researchers to audit the extent to which they are demonstrating rigour when writing up their studies. However, it should not be forgotten that rigour is built into the grounded theory method through the inductive-deductive cycle of theory generation. Care in applying the grounded theory methodology correctly is the single most important factor in ensuring rigour.

  3. Electric emissions from electrical appliances

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.

    2008-01-01

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intra-corporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration. (authors)

  4. Electrical characterization of zirconium substituted barium titanate ...

    Indian Academy of Sciences (India)

    been used as a tool to analyse electrical properties of the sample as a function of frequency and ... tures were thoroughly ground in an agate mortar and passed ... disk shaped pellets. ... Figure 2 shows variation of imaginary part of impedance.

  5. Electricity Customers

    Science.gov (United States)

    Residential, commercial, and industrial customers each account for roughly one-third of the nation’s electricity use. The transportation sector also accounts for a small fraction of electricity, although it could increase.

  6. [Introduction to grounded theory].

    Science.gov (United States)

    Wang, Shou-Yu; Windsor, Carol; Yates, Patsy

    2012-02-01

    Grounded theory, first developed by Glaser and Strauss in the 1960s, was introduced into nursing education as a distinct research methodology in the 1970s. The theory is grounded in a critique of the dominant contemporary approach to social inquiry, which imposed "enduring" theoretical propositions onto study data. Rather than starting from a set theoretical framework, grounded theory relies on researchers distinguishing meaningful constructs from generated data and then identifying an appropriate theory. Grounded theory is thus particularly useful in investigating complex issues and behaviours not previously addressed and concepts and relationships in particular populations or places that are still undeveloped or weakly connected. Grounded theory data analysis processes include open, axial and selective coding levels. The purpose of this article was to explore the grounded theory research process and provide an initial understanding of this methodology.

  7. Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment

    Energy Technology Data Exchange (ETDEWEB)

    Herms, C D

    1981-11-19

    Technical progress has not stopped short of electrical systems in mining, so that three new chapters are new included in the VDE regulations leaflet No. 0118 on 'Installation of electrical systems in underground coal mining'. The regulations on intrinsically safe electric systems, auxiliary circuits and communication systems are briefly described, and grounds for the regulations are presented. The regulations already take account of European regulations on intrinsic safety which will soon be published in a European Regulation on Mine Explosions. In the chapters on auxiliary circuits and communication systems, protection against direct contact, fires, and explosions is discussed as well as the further goal of reliable signal transmission.

  8. Electric drives

    CERN Document Server

    Boldea, Ion

    2005-01-01

    ENERGY CONVERSION IN ELECTRIC DRIVESElectric Drives: A DefinitionApplication Range of Electric DrivesEnergy Savings Pay Off RapidlyGlobal Energy Savings Through PEC DrivesMotor/Mechanical Load MatchMotion/Time Profile MatchLoad Dynamics and StabilityMultiquadrant OperationPerformance IndexesProblemsELECTRIC MOTORS FOR DRIVESElectric Drives: A Typical ConfigurationElectric Motors for DrivesDC Brush MotorsConventional AC MotorsPower Electronic Converter Dependent MotorsEnergy Conversion in Electric Motors/GeneratorsPOWER ELECTRONIC CONVERTERS (PECs) FOR DRIVESPower Electronic Switches (PESs)The

  9. Electrical contracting

    CERN Document Server

    Neidle, Michael

    2013-01-01

    Electrical Contracting, Second Edition is a nine-chapter text guide for the greater efficiency in planning and completing installations for the design, installation and control of electrical contracts. This book starts with a general overview of the efficient cabling and techniques that must be employed for safe wiring design, as well as the cost estimation of the complete electrical contract. The subsequent chapters are devoted to other electrical contracting requirements, including electronic motor control, lighting, and electricity tariffs. A chapter focuses on the IEE Wiring Regulations an

  10. The Grounded Theory Bookshelf

    Directory of Open Access Journals (Sweden)

    Vivian B. Martin, Ph.D.

    2005-03-01

    Full Text Available Bookshelf will provide critical reviews and perspectives on books on theory and methodology of interest to grounded theory. This issue includes a review of Heaton’s Reworking Qualitative Data, of special interest for some of its references to grounded theory as a secondary analysis tool; and Goulding’s Grounded Theory: A practical guide for management, business, and market researchers, a book that attempts to explicate the method and presents a grounded theory study that falls a little short of the mark of a fully elaborated theory.Reworking Qualitative Data, Janet Heaton (Sage, 2004. Paperback, 176 pages, $29.95. Hardcover also available.

  11. Hot Ground Vibration Tests

    Data.gov (United States)

    National Aeronautics and Space Administration — Ground vibration tests or modal surveys are routinely conducted to support flutter analysis for subsonic and supersonic vehicles. However, vibration testing...

  12. Electrical model of Olkiluoto

    Energy Technology Data Exchange (ETDEWEB)

    Paananen, M.; Lehtonen, T.; Korhonen, K. (Geological Survey of Finland, Espoo (FI))

    2007-05-15

    The goal of this work is to construct a composite electrical model of Olkiluoto, focussing on integration of four separate geophysical methods: mise-a-la-masse (MAM), SAMPO EM soundings, Slingram (HLEM) and single-hole electrical soundings. The electrical structure of Olkiluoto is rather complex, dominated by mineral electrical conductors such as sulphide minerals and graphite. The basic idea of this work is the fact that the sulphide-rich zones and fracturing appear to coincide frequently. Accordingly, knowing the geometry of the major electric conductors would facilitate the interpretation of brittle deformation zones. The work consists of three separate phases: method-specific interpretation, integration and block modelling. In the single-hole interpretation, locations of electric conductors (resistivity < 1000 ohmm), based on long normal survey have been determined in 42 drillholes. Since MAM survey does not cover all the conductive sections and drillholes and SAMPO EM has its own limitations in sensitivity and resolution, a proportion of the conductive sections have been combined between the drillholes using only the single-hole data and the geological idea of features dipping gently to SE - S. The MAM survey has been done in numerous drillholes in order to find galvanic connections between the drillholes. Based on MAM, geometry of numerous electric conductors has been determined. Generally the results indicate continuous, gently dipping semiplanar features intersected by several drillholes. The Slingram survey and interpretation have been done on the ground surface to map electric conductors located at shallow depths (some tens of meters at maximum). A number of conductive zones have been delineated, trending mainly from ENE to WSW. The conductors have also been classified according to their in-phase/quadrature-ratio, and in some cases, also numerical modelling has been done. The SAMPO EM soundings and interpretations have been done to map subsurface electric

  13. Electrical model of Olkiluoto

    International Nuclear Information System (INIS)

    Paananen, M.; Lehtonen, T.; Korhonen, K.

    2007-05-01

    The goal of this work is to construct a composite electrical model of Olkiluoto, focussing on integration of four separate geophysical methods: mise-a-la-masse (MAM), SAMPO EM soundings, Slingram (HLEM) and single-hole electrical soundings. The electrical structure of Olkiluoto is rather complex, dominated by mineral electrical conductors such as sulphide minerals and graphite. The basic idea of this work is the fact that the sulphide-rich zones and fracturing appear to coincide frequently. Accordingly, knowing the geometry of the major electric conductors would facilitate the interpretation of brittle deformation zones. The work consists of three separate phases: method-specific interpretation, integration and block modelling. In the single-hole interpretation, locations of electric conductors (resistivity < 1000 ohmm), based on long normal survey have been determined in 42 drillholes. Since MAM survey does not cover all the conductive sections and drillholes and SAMPO EM has its own limitations in sensitivity and resolution, a proportion of the conductive sections have been combined between the drillholes using only the single-hole data and the geological idea of features dipping gently to SE - S. The MAM survey has been done in numerous drillholes in order to find galvanic connections between the drillholes. Based on MAM, geometry of numerous electric conductors has been determined. Generally the results indicate continuous, gently dipping semiplanar features intersected by several drillholes. The Slingram survey and interpretation have been done on the ground surface to map electric conductors located at shallow depths (some tens of meters at maximum). A number of conductive zones have been delineated, trending mainly from ENE to WSW. The conductors have also been classified according to their in-phase/quadrature-ratio, and in some cases, also numerical modelling has been done. The SAMPO EM soundings and interpretations have been done to map subsurface electric

  14. Electric vehicles

    Science.gov (United States)

    1990-03-01

    Quiet, clean, and efficient, electric vehicles (EVs) may someday become a practical mode of transportation for the general public. Electric vehicles can provide many advantages for the nation's environment and energy supply because they run on electricity, which can be produced from many sources of energy such as coal, natural gas, uranium, and hydropower. These vehicles offer fuel versatility to the transportation sector, which depends almost solely on oil for its energy needs. Electric vehicles are any mode of transportation operated by a motor that receives electricity from a battery or fuel cell. EVs come in all shapes and sizes and may be used for different tasks. Some EVs are small and simple, such as golf carts and electric wheel chairs. Others are larger and more complex, such as automobile and vans. Some EVs, such as fork lifts, are used in industries. In this fact sheet, we will discuss mostly automobiles and vans. There are also variations on electric vehicles, such as hybrid vehicles and solar-powered vehicles. Hybrid vehicles use electricity as their primary source of energy, however, they also use a backup source of energy, such as gasoline, methanol or ethanol. Solar-powered vehicles are electric vehicles that use photovoltaic cells (cells that convert solar energy to electricity) rather than utility-supplied electricity to recharge the batteries. These concepts are discussed.

  15. ELECTRICAL TECHNIQUES FOR ENGINEERING APPLICATIONS.

    Science.gov (United States)

    Bisdorf, Robert J.

    1985-01-01

    Surface electrical geophysical methods have been used in such engineering applications as locating and delineating shallow gravel deposits, depth to bedrock, faults, clay zones, and other geological phenomena. Other engineering applications include determining water quality, tracing ground water contaminant plumes and locating dam seepages. Various methods and electrode arrays are employed to solve particular geological problems. The sensitivity of a particular method or electrode array depends upon the physics on which the method is based, the array geometry, the electrical contrast between the target and host materials, and the depth to the target. Each of the available electrical methods has its own particular advantages and applications which the paper discusses.

  16. Improved di-electric composition

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, R C

    1915-03-29

    An improved di-electric composition is disclosed composed of pitch or bitumen which is melted, and to which is added, while molten, a quantity of finely ground or pulverized spent shale, the whole being mixed or stirred to make a homogeneous composition, substantially as described.

  17. Hybrid Turbine Electric Vehicle

    Science.gov (United States)

    Viterna, Larry A.

    1997-01-01

    Hybrid electric power trains may revolutionize today's ground passenger vehicles by significantly improving fuel economy and decreasing emissions. The NASA Lewis Research Center is working with industry, universities, and Government to develop and demonstrate a hybrid electric vehicle. Our partners include Bowling Green State University, the Cleveland Regional Transit Authority, Lincoln Electric Motor Division, the State of Ohio's Department of Development, and Teledyne Ryan Aeronautical. The vehicle will be a heavy class urban transit bus offering double the fuel economy of today's buses and emissions that are reduced to 1/10th of the Environmental Protection Agency's standards. At the heart of the vehicle's drive train is a natural-gas-fueled engine. Initially, a small automotive engine will be tested as a baseline. This will be followed by the introduction of an advanced gas turbine developed from an aircraft jet engine. The engine turns a high-speed generator, producing electricity. Power from both the generator and an onboard energy storage system is then provided to a variable-speed electric motor attached to the rear drive axle. An intelligent power-control system determines the most efficient operation of the engine and energy storage system.

  18. Analytical and finite element modeling of grounding systems

    Energy Technology Data Exchange (ETDEWEB)

    Luz, Mauricio Valencia Ferreira da [University of Santa Catarina (UFSC), Florianopolis, SC (Brazil)], E-mail: mauricio@grucad.ufsc.br; Dular, Patrick [University of Liege (Belgium). Institut Montefiore], E-mail: Patrick.Dular@ulg.ac.be

    2007-07-01

    Grounding is the art of making an electrical connection to the earth. This paper deals with the analytical and finite element modeling of grounding systems. An electrokinetic formulation using a scalar potential can benefit from floating potentials to define global quantities such as electric voltages and currents. The application concerns a single vertical grounding with one, two and three-layer soil, where the superior extremity stays in the surface of the soil. This problem has been modeled using a 2D axi-symmetric electrokinetic formulation. The grounding resistance obtained by finite element method is compared with the analytical one for one-layer soil. With the results of this paper it is possible to show that finite element method is a powerful tool in the analysis of the grounding systems in low frequencies. (author)

  19. The ATLAS SCT grounding and shielding concept and implementation

    CERN Document Server

    Bates, RL; Bernabeu, J; Bizzell, J; Bohm, J; Brenner, R; Bruckman de Renstrom, P A; Catinaccio, A; Cindro, V; Ciocio, A; Civera, J V; Chouridou, S; Dervan, P; Dick, B; Dolezal, Z; Eklund, L; Feld, L; Ferrere, D; Gadomski, S; Gonzalez, F; Gornicki, E; Greenhall, A; Grillo, A A; Grosse-Knetter, J; Gruwe, M; Haywood, S; Hessey, N P; Ikegami, Y; Jones, T J; Kaplon, J; Kodys, P; Kohriki, T; Kondo, T; Koperny, S; Lacasta, C; Lozano Bahilo, J; Malecki, P; Martinez-McKinney, F; McMahon, S J; McPherson, A; Mikulec, B; Mikus, M; Moorhead, G F; Morrissey, M C; Nagai, K; Nichols, A; O'Shea, V; Pater, J R; Peeters, S J M; Pernegger, H; Perrin, E; Phillips, P W; Pieron, J P; Roe, S; Sanchez, J; Spencer, E; Stastny, J; Tarrant, J; Terada, S; Tyndel, M; Unno, Y; Wallny, R; Weber, M; Weidberg, A R; Wells, P S; Werneke, P; Wilmut, I

    2012-01-01

    This paper describes the design and implementation of the grounding and shielding system for the ATLAS SemiConductor Tracker (SCT). The mitigation of electromagnetic interference and noise pickup through power lines is the critical design goal as they have the potential to jeopardize the electrical performance. We accomplish this by adhering to the ATLAS grounding rules, by avoiding ground loops and isolating the different subdetectors. Noise sources are identified and design rules to protect the SCT against them are described. A rigorous implementation of the design was crucial to achieve the required performance. This paper highlights the location, connection and assembly of the different components that affect the grounding and shielding system: cables, filters, cooling pipes, shielding enclosure, power supplies and others. Special care is taken with the electrical properties of materials and joints. The monitoring of the grounding system during the installation period is also discussed. Finally, after con...

  20. Sail GTS ground system analysis: Avionics system engineering

    Science.gov (United States)

    Lawton, R. M.

    1977-01-01

    A comparison of two different concepts for the guidance, navigation and control test set signal ground system is presented. The first is a concept utilizing a ground plate to which crew station, avionics racks, electrical power distribution system, master electrical common connection assembly and marshall mated elements system grounds are connected by 4/0 welding cable. An alternate approach has an aluminum sheet interconnecting the signal ground reference points between the crew station and avionics racks. The comparison analysis quantifies the differences between the two concepts in terms of dc resistance, ac resistance and inductive reactance. These parameters are figures of merit for ground system conductors in that the system with the lowest impedance is the most effective in minimizing noise voltage. Although the welding cable system is probably adequate, the aluminum sheet system provides a higher probability of a successful system design.

  1. Efektivitas Instagram Common Grounds

    OpenAIRE

    Wifalin, Michelle

    2016-01-01

    Efektivitas Instagram Common Grounds merupakan rumusan masalah yang diambil dalam penelitian ini. Efektivitas Instagram diukur menggunakan Customer Response Index (CRI), dimana responden diukur dalam berbagai tingkatan, mulai dari awareness, comprehend, interest, intentions dan action. Tingkatan respons inilah yang digunakan untuk mengukur efektivitas Instagram Common Grounds. Teori-teori yang digunakan untuk mendukung penelitian ini yaitu teori marketing Public Relations, teori iklan, efekti...

  2. Pesticides in Ground Water

    DEFF Research Database (Denmark)

    Bjerg, Poul Løgstrup

    1996-01-01

    Review af: Jack E. Barbash & Elizabeth A. Resek (1996). Pesticides in Ground Water. Distribution trends and governing factors. Ann Arbor Press, Inc. Chelsea, Michigan. pp 588.......Review af: Jack E. Barbash & Elizabeth A. Resek (1996). Pesticides in Ground Water. Distribution trends and governing factors. Ann Arbor Press, Inc. Chelsea, Michigan. pp 588....

  3. 14 CFR Appendix J to Part 417 - Ground Safety Analysis Report

    Science.gov (United States)

    2010-01-01

    ... and pressure systems; (iv) Electrical and non-ionizing radiation systems; and (v) Ionizing radiation...) Electrical and non-ionizing radiation ground support and checkout systems; (v) Ionizing radiation ground... each special interest issue, such as a high-risk situation or potential non-compliance with any...

  4. The Grounded Theory Bookshelf

    Directory of Open Access Journals (Sweden)

    Dr. Alvita Nathaniel, DSN, APRN, BC

    2005-06-01

    Full Text Available The Grounded Theory Perspective III: Theoretical Coding, Barney G. Glaser (Sociology Press, 2005. Not intended for a beginner, this book further defi nes, describes, and explicates the classic grounded theory (GT method. Perspective III lays out various facets of theoretical coding as Glaser meticulously distinguishes classic GT from other subsequent methods. Developed many years after Glaser’s classic GT, these methods, particularly as described by Strauss and Corbin, adopt the grounded theory name and engender ongoing confusion about the very premises of grounded theory. Glaser distinguishes between classic GT and the adscititious methods in his writings, referring to remodeled grounded theory and its offshoots as Qualitative Data Analysis (QDA models.

  5. Communication, concepts and grounding.

    Science.gov (United States)

    van der Velde, Frank

    2015-02-01

    This article discusses the relation between communication and conceptual grounding. In the brain, neurons, circuits and brain areas are involved in the representation of a concept, grounding it in perception and action. In terms of grounding we can distinguish between communication within the brain and communication between humans or between humans and machines. In the first form of communication, a concept is activated by sensory input. Due to grounding, the information provided by this communication is not just determined by the sensory input but also by the outgoing connection structure of the conceptual representation, which is based on previous experiences and actions. The second form of communication, that between humans or between humans and machines, is influenced by the first form. In particular, a more successful interpersonal communication might require forms of situated cognition and interaction in which the entire representations of grounded concepts are involved. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Stochastic ground motion simulation

    Science.gov (United States)

    Rezaeian, Sanaz; Xiaodan, Sun; Beer, Michael; Kougioumtzoglou, Ioannis A.; Patelli, Edoardo; Siu-Kui Au, Ivan

    2014-01-01

    Strong earthquake ground motion records are fundamental in engineering applications. Ground motion time series are used in response-history dynamic analysis of structural or geotechnical systems. In such analysis, the validity of predicted responses depends on the validity of the input excitations. Ground motion records are also used to develop ground motion prediction equations(GMPEs) for intensity measures such as spectral accelerations that are used in response-spectrum dynamic analysis. Despite the thousands of available strong ground motion records, there remains a shortage of records for large-magnitude earthquakes at short distances or in specific regions, as well as records that sample specific combinations of source, path, and site characteristics.

  7. Electric shock and electrical fire specialty

    International Nuclear Information System (INIS)

    2011-02-01

    This book deals with electric shock and electrical fire, which is made up seven chapters. It describes of special measurement for electric shock and electrical fire. It mentions concretely about electrical fire analysis and precautionary measurement, electrical shock analysis cases, occurrence of static electricity and measurement, gas accident, analysis of equipment accident and precautionary measurement. The book is published to educate the measurement on electric shock and electrical fire by electrical safety technology education center in Korea Electrical Safety Corporation.

  8. High-altitude electromagnetic pulse environment over the lossy ground

    International Nuclear Information System (INIS)

    Xie Yanzhao; Wang Zanji

    2003-01-01

    The electromagnetic field above ground produced by an incident high-altitude electromagnetic pulse plane wave striking the ground plane was described in this paper in terms of the Fresnel reflection coefficients and the numerical FFT. The pulse reflected from the ground plane always cancel the incident field for the horizontal field component, but the reflected field adds to the incident for the vertical field component. The results of several cases for variations in the observation height, angle of incidence and lossy ground electrical parameters were also presented showing different e-field components above the earth

  9. Static electricity: A literature review

    Science.gov (United States)

    Crow, Rita M.

    1991-11-01

    The major concern with static electricity is its discharging in a flammable atmosphere which can explode and cause a fire. Textile materials can have their electrical resistivity decreased by the addition of antistatic finishes, imbedding conductive particles into the fibres or by adding metal fibers to the yarns. The test methods used in the studies of static electricity include measuring the static properties of materials, of clothed persons, and of the ignition energy of flammable gases. Surveys have shown that there is sparse evidence for fires definitively being caused by static electricity. However, the 'worst-case' philosophy has been adopted and a static electricity safety code is described, including correct grounding procedures and the wearing of anti-static clothing and footwear.

  10. 30 CFR 75.814 - Electrical protection.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electrical protection. 75.814 Section 75.814... Longwalls § 75.814 Electrical protection. (a) High-voltage circuits must be protected against short circuits... with— (i) Ground-fault protection set to cause deenergization at not more than 40 percent of the...

  11. The electrical system of nuclear power plant

    International Nuclear Information System (INIS)

    Firman Silitonga; Gunarwan Prayitno

    2009-01-01

    In these system, electrical power system is supplied from two-offsite transmission system respective main transformer and house service transformer; and reserve transformer. The electrical load in these system consist of safety electrical system and non-safety electrical system, The safety electrical and non safety electrical systems consist of four 6,9 kV AC medium voltage bus and 480 V AC low voltage bus system. The DC power system consist of four safety 125 V DC power system and the two non-safety 125 DC power systems. The equipment in these electrical system is main turbine-generator; GTG safety; GTG alternate; uninterrupted power supply (UPS) and battery system. To protect electrical equipment and building to direct stroke and non direct stroke disturbances is installed netral grounding system and lightning protection and protection the personnel to touch-voltage is installed equipment grounding system and station grounding. The lightning arrester system is connected to station station grounding system. (author)

  12. Electric Substations

    Data.gov (United States)

    Department of Homeland Security — Substations. Substations are facilities and equipment that switch, transform, or regulate electric voltage. The Substations feature class includes taps, a location...

  13. Atmospheric electricity

    CERN Document Server

    Chalmers, J Alan

    1957-01-01

    Atmospheric Electricity brings together numerous studies on various aspects of atmospheric electricity. This book is composed of 13 chapters that cover the main problems in the field, including the maintenance of the negative charge on the earth and the origin of the charges in thunderstorms. After a brief overview of the historical developments of atmospheric electricity, this book goes on dealing with the general principles, results, methods, and the MKS system of the field. The succeeding chapters are devoted to some aspects of electricity in the atmosphere, such as the occurrence and d

  14. TARDEC Overview: Ground Vehicle Power and Mobility

    Science.gov (United States)

    2011-02-04

    Fuel & Water Distribution • Force Sustainment • Construction Equipment • Bridging • Assured Mobility Systems Robotics • TALON • PackBot • MARCbot...Equipment • Mechanical Countermine Equipment • Tactical Bridging Intelligent Ground Systems • Autonomous Robotics Systems • Safe Operations...Test Cell • Hybrid Electric Reconfigurable Moveable Integration Testbed (HERMIT) • Electro-chemical Analysis and Research Lab (EARL) • Battery Lab • Air

  15. Towards the design of a RF-harvesting EBG ground plane

    NARCIS (Netherlands)

    Visser, H.J.; Keyrouz, S.

    2015-01-01

    Electromagnetic Band Gap (EBG) structures may be used to create magnetic conductors that can be used as ground planes for dipole and loop-like antennas without annihilating the radiation as electrically conducting ground planes would do. An EBG ground plane may be created by placing a Frequency

  16. Influence of electric field, hydrostatic pressure and temperature on the electric state in a Poschl-Teller quantum well

    International Nuclear Information System (INIS)

    Hakimyfard, A.; Barseghyan, M.G.; Kirakosyan, A.A.; Duque, C.A.

    2010-01-01

    Influence of the electric field and hydrostatic pressure on the electronic states in a Poschl-Teller quantum well is studied. In the framework of variational method the dependences of the ground state energy on the electric field and hydrostatic pressure are calculated for different values of the potential parameters and the temperature. It is shown that the increase in the electric field leads to the increase in the ground state energy, while the increase in the well width leads to the strengthening of the electric field effect. The ground state energy decreases with increasing pressure and increases with increasing temperature

  17. Electric power systems

    CERN Document Server

    Weedy, B M; Jenkins, N; Ekanayake, J B; Strbac, G

    2012-01-01

    The definitive textbook for Power Systems students, providing a grounding in essential power system theory while also focusing on practical power engineering applications. Electric Power Systems has been an essential book in power systems engineering for over thirty years. Bringing the content firmly up-to-date whilst still retaining the flavour of Weedy's extremely popular original, this Fifth Edition has been revised by experts Nick Jenkins, Janaka Ekanayake and Goran Strbac. This wide-ranging text still covers all of the fundamental power systems subjects but is now e

  18. Electric machine

    Science.gov (United States)

    El-Refaie, Ayman Mohamed Fawzi [Niskayuna, NY; Reddy, Patel Bhageerath [Madison, WI

    2012-07-17

    An interior permanent magnet electric machine is disclosed. The interior permanent magnet electric machine comprises a rotor comprising a plurality of radially placed magnets each having a proximal end and a distal end, wherein each magnet comprises a plurality of magnetic segments and at least one magnetic segment towards the distal end comprises a high resistivity magnetic material.

  19. Teaching Electricity.

    Science.gov (United States)

    Iona, Mario

    1982-01-01

    To clarify the meaning of electrical terms, a chart is used to compare electrical concepts and relationships with a more easily visualized system in which water flows from a hilltop reservoir through a pipe to drive a mill at the bottom of the hill. A diagram accompanies the chart. (Author/SK)

  20. Adding Theoretical Grounding to Grounded Theory: Toward Multi-Grounded Theory

    OpenAIRE

    Göran Goldkuhl; Stefan Cronholm

    2010-01-01

    The purpose of this paper is to challenge some of the cornerstones of the grounded theory approach and propose an extended and alternative approach for data analysis and theory development, which the authors call multi-grounded theory (MGT). A multi-grounded theory is not only empirically grounded; it is also grounded in other ways. Three different grounding processes are acknowledged: theoretical, empirical, and internal grounding. The authors go beyond the pure inductivist approach in GT an...

  1. Grounding of SNS Accelerator Structure

    CERN Document Server

    Holik, Paul S

    2005-01-01

    Description of site general grounding network. RF grounding network enhancement underneath the klystron gallery building. Grounding network of the Ring Systems with ground breaks in the Ring Tunnel. Grounding and Bonding of R&D accelerator equipment. SNS Building lightning protection.

  2. Airfield Ground Safety

    National Research Council Canada - National Science Library

    Petrescu, Jon

    2000-01-01

    .... The system developed under AGS, called the Ground Safety Tracking and Reporting System, uses multisensor data fusion from in-pavement inductive loop sensors to address a critical problem affecting out nation's airports: runway incursions...

  3. Grounded meets floating

    Science.gov (United States)

    Walker, Ryan T.

    2018-04-01

    A comprehensive assessment of grounding-line migration rates around Antarctica, covering a third of the coast, suggests retreat in considerable portions of the continent, beyond the rates expected from adjustment following the Last Glacial Maximum.

  4. Ground water and earthquakes

    Energy Technology Data Exchange (ETDEWEB)

    Ts' ai, T H

    1977-11-01

    Chinese folk wisdom has long seen a relationship between ground water and earthquakes. Before an earthquake there is often an unusual change in the ground water level and volume of flow. Changes in the amount of particulate matter in ground water as well as changes in color, bubbling, gas emission, and noises and geysers are also often observed before earthquakes. Analysis of these features can help predict earthquakes. Other factors unrelated to earthquakes can cause some of these changes, too. As a first step it is necessary to find sites which are sensitive to changes in ground stress to be used as sensor points for predicting earthquakes. The necessary features are described. Recording of seismic waves of earthquake aftershocks is also an important part of earthquake predictions.

  5. Effect of electrode shape on grounding resistances - Part 2

    DEFF Research Database (Denmark)

    Tomaskovicova, Sonia; Ingeman-Nielsen, Thomas; Christiansen, Anders V.

    2016-01-01

    Although electric resistivity tomography (ERT) is now regarded as a standard tool in permafrost monitoring, high grounding resistances continue to limit the acquisition of time series over complete freeze-thaw cycles. In an attempt to alleviate the grounding resistance problem, we have tested three...... electrode designs featuring increasing sizes and surface area, in the laboratory and at three different field sites in Greenland. Grounding resistance measurements showed that changing the electrode shape (using plates instead of rods) reduced the grounding resistances at all sites by 28%-69% during...... unfrozen and frozen ground conditions. Using meshes instead of plates (the same rectangular shape and a larger effective surface area) further improved the grounding resistances by 29%-37% in winter. Replacement of rod electrodes of one entire permanent permafrost monitoring array by meshes resulted...

  6. Yet Another Puzzle of Ground

    NARCIS (Netherlands)

    Korbmacher, J.

    2015-01-01

    We show that any predicational theory of partial ground that extends a standard theory of syntax and that proves some commonly accepted principles for partial ground is inconsistent. We suggest a way to obtain a consistent predicational theory of ground.

  7. Electric drives

    Energy Technology Data Exchange (ETDEWEB)

    1986-10-01

    Several electric vehicles have been tested in long-term tests, i.e. an electric passenger car (maximum speed 115 km/h) and several busses for use in pedestrians' zones, spas, airports, natural reserves, and urban transportation (DUO busses). The ICE high-speed train is discussed in some detail, i.e. its aeroacoustic and aerodynamic design, running gear, computer-controlled drives and brakes, diagnostic systems, and electrical equipment. The Berlin Maglev system is mentioned as well as current inverters in rail vehicles. (HWJ).

  8. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  9. Electricity derivatives

    CERN Document Server

    Aïd, René

    2015-01-01

    Offering a concise but complete survey of the common features of the microstructure of electricity markets, this book describes the state of the art in the different proposed electricity price models for pricing derivatives and in the numerical methods used to price and hedge the most prominent derivatives in electricity markets, namely power plants and swings. The mathematical content of the book has intentionally been made light in order to concentrate on the main subject matter, avoiding fastidious computations. Wherever possible, the models are illustrated by diagrams. The book should allow prospective researchers in the field of electricity derivatives to focus on the actual difficulties associated with the subject. It should also offer a brief but exhaustive overview of the latest techniques used by financial engineers in energy utilities and energy trading desks.

  10. Electric empire

    International Nuclear Information System (INIS)

    McKay, Paul

    1983-01-01

    The author discusses the economic and political aspects of Ontario Hydro, a provincial crown corporation. He also deals with nuclear safety of the CANDU reactors and the ecological effects of electric power supply. Alternate sources of energy are also mentioned

  11. Electrical Conductivity.

    Science.gov (United States)

    Hershey, David R.; Sand, Susan

    1993-01-01

    Explains how electrical conductivity (EC) can be used to measure ion concentration in solutions. Describes instrumentation for the measurement, temperature dependence and EC, and the EC of common substances. (PR)

  12. Electric theory

    International Nuclear Information System (INIS)

    Gong, Ha Seong

    2006-02-01

    This book explains electric theory which is divided into four chapters. The first chapter includes electricity and material, electric field, capacitance, magnetic field and electromagnetic force, inductance. The second chapter mentions electronic circuit analysis, electric resistance,heating and power, chemical activity on current and battery with electrolysis. The third chapter deals with an alternating current circuit about the basics of an AC circuit, operating of resistance, inductance and capacitance, series circuit and parallel circuit of PLC, an alternating current circuit, Three-phase Alternating current, two terminal pair network and voltage and current of non-linearity circuit. The last explains transient phenomena of RC series circuit, RL series circuit, transient phenomena of an alternating current circuit and transient phenomena of RLC series circuit.

  13. Electrical injury

    Science.gov (United States)

    ... RS, Gausche-Hill M, eds. Rosen's Emergency Medicine: Concepts and Clinical Practice. 9th ed. Philadelphia, PA: Elsevier; 2018:chap 134. Price LA, Loiacono LA. Electrical and lightning injury. In: Cameron JL, Cameron AM, eds. Current Surgical ...

  14. Renewable Energy Opportunties at Dugway Proving Ground, Utah

    Energy Technology Data Exchange (ETDEWEB)

    Orrell, Alice C.; Kora, Angela R.; Russo, Bryan J.; Horner, Jacob A.; Williamson, Jennifer L.; Weimar, Mark R.; Gorrissen, Willy J.; Nesse, Ronald J.; Dixon, Douglas R.

    2010-05-31

    This document provides an overview of renewable resource potential at Dugway Proving Ground, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and ground source heat pumps (GSHPs). The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment.

  15. Move of ground water

    International Nuclear Information System (INIS)

    Kimura, Shigehiko

    1983-01-01

    As a ground water flow which is difficult to explain by Darcy's theory, there is stagnant water in strata, which moves by pumping and leads to land subsidence. This is now a major problem in Japan. Such move on an extensive scale has been investigated in detail by means of 3 H such as from rainfall in addition to ordinary measurement. The move of ground water is divided broadly into that in an unsaturated stratum from ground surface to water-table and that in a saturated stratum below the water-table. The course of the analyses made so far by 3 H contained in water, and the future trend of its usage are described. A flow model of regarding water as plastic fluid and its flow as channel assembly may be available for some flow mechanism which is not possible to explain with Darcy's theory. (Mori, K.)

  16. Ground motion predictions

    Energy Technology Data Exchange (ETDEWEB)

    Loux, P C [Environmental Research Corporation, Alexandria, VA (United States)

    1969-07-01

    Nuclear generated ground motion is defined and then related to the physical parameters that cause it. Techniques employed for prediction of ground motion peak amplitude, frequency spectra and response spectra are explored, with initial emphasis on the analysis of data collected at the Nevada Test Site (NTS). NTS postshot measurements are compared with pre-shot predictions. Applicability of these techniques to new areas, for example, Plowshare sites, must be questioned. Fortunately, the Atomic Energy Commission is sponsoring complementary studies to improve prediction capabilities primarily in new locations outside the NTS region. Some of these are discussed in the light of anomalous seismic behavior, and comparisons are given showing theoretical versus experimental results. In conclusion, current ground motion prediction techniques are applied to events off the NTS. Predictions are compared with measurements for the event Faultless and for the Plowshare events, Gasbuggy, Cabriolet, and Buggy I. (author)

  17. Ground motion predictions

    International Nuclear Information System (INIS)

    Loux, P.C.

    1969-01-01

    Nuclear generated ground motion is defined and then related to the physical parameters that cause it. Techniques employed for prediction of ground motion peak amplitude, frequency spectra and response spectra are explored, with initial emphasis on the analysis of data collected at the Nevada Test Site (NTS). NTS postshot measurements are compared with pre-shot predictions. Applicability of these techniques to new areas, for example, Plowshare sites, must be questioned. Fortunately, the Atomic Energy Commission is sponsoring complementary studies to improve prediction capabilities primarily in new locations outside the NTS region. Some of these are discussed in the light of anomalous seismic behavior, and comparisons are given showing theoretical versus experimental results. In conclusion, current ground motion prediction techniques are applied to events off the NTS. Predictions are compared with measurements for the event Faultless and for the Plowshare events, Gasbuggy, Cabriolet, and Buggy I. (author)

  18. The electric motor handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Feltham, P. (eds.)

    2004-05-01

    This handbook outlines the important role that electric motors play in modern society. It covers the field of motor applications from various motor types to their use and repair. It also presents practical applications of electric motors and methods on motor efficiency. More than half of all electricity generated, and 75 per cent of all industrial electricity consumption is consumed by electric motors. Electrical personnel must be aware of all factors involved in electric motors in order to choose and apply the appropriate size of electric motor. These factors include efficiency, sizing and proper application. The efficient use and maximum life expectancy of electric motors depends on proper motor protection, control and maintenance. This handbook includes articles from leading experts on electric motors in modern electrical systems. The content includes: design considerations; proper electric motor sizing techniques; optimal electric motor application; electric motor protection technology; electric motor control principles; electric motor maintenance and troubleshooting; induction electric motors; electric motor bearing currents; electric motor bearing lubrication; electromagnetism; electric motor enclosures; electric motor testing; electric motor repair; DC electric motor; electric motor starters; electric motor brushes; industrial electric motors; electric motor diagrams; AC electric motors; electric motor wiring; electric motor service; electric motor rewinding; electric motor winding; diagram of electric motor wiring; electric motor kit; and, troubleshooting electric motors. A directory of motor manufacturers and suppliers was also included. refs., tabs., figs.

  19. Electrical design of TNS

    International Nuclear Information System (INIS)

    Heck, F.M.; Schultz, J.H.; Smeltzer, G.S.

    1977-01-01

    The electrical design of the ORNL-Westinghouse next step (TNS) fusion reactor was begun in 1976, using a set of ground rules which were based on the overall program objectives. These objectives were to identify the design of reasonably-priced reactors, which would achieve ignition and be technology forcing. The term ''technology forcing'' was understood to mean the desirability of a large number of ignited D-T pulses and the incorporation of superconducting toroidal field (TF) coils, if at all possible. A trade study methodology was developed to compare different machine sizes and TF coil technologies and to aid in the selection of system and subsystem design approaches. The logic which led from the program objectives to the design ground rules and from the ground rules to the circuit selection is described below. The circuit design approaches were generalized and these models were incorporated into a computer program (COAST) which was used to examine the cost of overall tokamak systems as key design parameters were varied

  20. Graphene ground states

    Science.gov (United States)

    Friedrich, Manuel; Stefanelli, Ulisse

    2018-06-01

    Graphene is locally two-dimensional but not flat. Nanoscale ripples appear in suspended samples and rolling up often occurs when boundaries are not fixed. We address this variety of graphene geometries by classifying all ground-state deformations of the hexagonal lattice with respect to configurational energies including two- and three-body terms. As a consequence, we prove that all ground-state deformations are either periodic in one direction, as in the case of ripples, or rolled up, as in the case of nanotubes.

  1. Technique applied in electrical power distribution for Satellite Launch Vehicle

    Directory of Open Access Journals (Sweden)

    João Maurício Rosário

    2010-09-01

    Full Text Available The Satellite Launch Vehicle electrical network, which is currently being developed in Brazil, is sub-divided for analysis in the following parts: Service Electrical Network, Controlling Electrical Network, Safety Electrical Network and Telemetry Electrical Network. During the pre-launching and launching phases, these electrical networks are associated electrically and mechanically to the structure of the vehicle. In order to succeed in the integration of these electrical networks it is necessary to employ techniques of electrical power distribution, which are proper to Launch Vehicle systems. This work presents the most important techniques to be considered in the characterization of the electrical power supply applied to Launch Vehicle systems. Such techniques are primarily designed to allow the electrical networks, when submitted to the single-phase fault to ground, to be able of keeping the power supply to the loads.

  2. Greengrid Electric

    International Nuclear Information System (INIS)

    Argue, D.

    1998-01-01

    This presentation focused on what customers want from a competitive electricity market and what motivates customers to choose a renewable energy product and service. Greengrid Electric, a subsidiary of Enershare Technology Corp., intends to provide the green electricity that they believe customers have wanted for some time. Enershare and Greengrid have been active participants in the electricity restructuring process in Ontario, and have provided input to the Market Design Committee. Once licensed as a retailer, Greengrid intends to be the major provider of green electricity in Ontario. The company will supply a 100 per cent renewable energy product to their wholesale and retail customers. The company is confident that there is a significant niche market in Ontario for selling a green product that has a blend of wind, small hydro (run-of-river or existing dam), solar, and for energy produced from capturing methane gas from municipal landfill sites. Company officials are confident that customers will be willing to pay a premium price for energy if their purchases will lead to environmental improvement

  3. Electric fields in the magnetosphere

    International Nuclear Information System (INIS)

    Faelthammar, C.G.

    1989-12-01

    The electric field plays an important role in the complex plasma system called the magnetosphere. In spite of this, direct measurement of this quantity are still scarce except in its lowest-altitude part, i.e. the ionosphere. The large scale ionospheric electric field has been determined from measurement on the ground and in low satellite orbit. For most of the magnetosphere, our concepts of the electric field have mostly been based on theoretical considerations and extrapolations of the ionspheric electric field. Direct, in situ, electric field measurements in the outer parts of the magnetosphere have been made only relatively recently. A few satellite missions. most recently the Viking mission, have extended the direct empirical knowledge so as to include major parts of the magnetosphere. These measurements have revealed a number of unexpected features. The actual electric field has been found to have unexpectedly strong space and time variations, which reflect the dynamic nature of the system. Examples are give of measured electric fields in the plasmasphere, the plasmasheet, the neutral sheet, the magnetotail, the flanks of the magnetosphere, the dayside magnetopause and the auroral acceleration region. (author)

  4. Nuclear ground state

    International Nuclear Information System (INIS)

    Negele, J.W.

    1975-01-01

    The nuclear ground state is surveyed theoretically, and specific suggestions are given on how to critically test the theory experimentally. Detailed results on 208 Pb are discussed, isolating several features of the charge density distributions. Analyses of 208 Pb electron scattering and muonic data are also considered. 14 figures

  5. Informed Grounded Theory

    Science.gov (United States)

    Thornberg, Robert

    2012-01-01

    There is a widespread idea that in grounded theory (GT) research, the researcher has to delay the literature review until the end of the analysis to avoid contamination--a dictum that might turn educational researchers away from GT. Nevertheless, in this article the author (a) problematizes the dictum of delaying a literature review in classic…

  6. Mechanics of Ship Grounding

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup

    1996-01-01

    In these notes first a simplified mathematical model is presented for analysis of ship hull loading due to grounding on relatively hard and plane sand, clay or rock sea bottoms. In a second section a more rational calculation model is described for the sea bed soil reaction forces on the sea bott...

  7. Singlet Ground State Magnetism:

    DEFF Research Database (Denmark)

    Loidl, A.; Knorr, K.; Kjems, Jørgen

    1979-01-01

    The magneticGamma 1 –Gamma 4 exciton of the singlet ground state system TbP has been studied by inelastic neutron scattering above the antiferromagnetic ordering temperature. Considerable dispersion and a pronounced splitting was found in the [100] and [110] directions. Both the band width...

  8. Grounding Anger Management

    Directory of Open Access Journals (Sweden)

    Odis E. Simmons, PhD

    2017-06-01

    Full Text Available One of the things that drew me to grounded theory from the beginning was Glaser and Strauss’ assertion in The Discovery of Grounded Theory that it was useful as a “theoretical foothold” for practical applications (p. 268. From this, when I was a Ph.D student studying under Glaser and Strauss in the early 1970s, I devised a GT based approach to action I later came to call “grounded action.” In this short paper I’ll present a very brief sketch of an anger management program I developed in 1992, using grounded action. I began my research by attending a two-day anger management training workshop designed for training professionals in the most commonly used anger management model. Like other intervention programs I had seen, this model took a psychologizing and pathologizing approach to the issue. Following this, I sat through the full course of an anger management program that used this model, observing the reactions of the participants and the approach of the facilitator. Following each session I conducted open-ended interviews with most of the participants, either individually or in groups of two or three. I had also done previous research in counseling and social work contexts that turned out to be very relevant to an anger management program design.

  9. Grounding in Instant Messaging

    Science.gov (United States)

    Fox Tree, Jean E.; Mayer, Sarah A.; Betts, Teresa E.

    2011-01-01

    In two experiments, we investigated predictions of the "collaborative theory of language use" (Clark, 1996) as applied to instant messaging (IM). This theory describes how the presence and absence of different grounding constraints causes people to interact differently across different communicative media (Clark & Brennan, 1991). In Study 1, we…

  10. Collison and Grounding

    DEFF Research Database (Denmark)

    Wang, G.; Ji, C.; Kuhala, P.

    2006-01-01

    COMMITTEE MANDATE Concern for structural arrangements on ships and floating structures with regard to their integrity and adequacy in the events of collision and grounding, with the view towards risk assessment and management. Consideration shall be given to the frequency of occurrence...

  11. Space weather effects on ground based technology

    Science.gov (United States)

    Clark, T.

    Space weather can affect a variety of forms of ground-based technology, usually as a result of either the direct effects of the varying geomagnetic field, or as a result of the induced electric field that accompanies such variations. Technologies affected directly by geomagnetic variations include magnetic measurements made d ringu geophysical surveys, and navigation relying on the geomagnetic field as a direction reference, a method that is particularly common in the surveying of well-bores in the oil industry. The most obvious technology affected by induced electric fields during magnetic storms is electric power transmission, where the example of the blackout in Quebec during the March 1989 magnetic storm is widely known. Additionally, space weather effects must be taken into account in the design of active cathodic protection systems on pipelines to protect them against corrosion. Long-distance telecommunication cables may also have to be designed to cope with space weather related effects. This paper reviews the effects of space weather in these different areas of ground-based technology, and provides examples of how mitigation against hazards may be achieved. (The paper does not include the effects of space weather on radio communication or satellite navigation systems).

  12. Geothermal energy. Ground source heat pumps

    International Nuclear Information System (INIS)

    2009-01-01

    Geothermal energy can be harnessed in 2 different ways: electricity or heat generation. The combined net electrical geothermal power of the European Union countries reached 719.3 MWe in 2008 (4.8 MW up on 2007) for 868.1 MWe of installed capacity. Gross electrical production contracted slightly in 2008 (down 1% on the 2007 level) and stood at 5809.5 GWh in 2008. Italy has a overwhelming position with a production of 5520.3 GWh. Geothermal heat production concerning aquifers whose temperature is 30-150 C. degrees generally at a depth of 1-3 km is called low- and medium-enthalpy energy. 18 of the 27 EU members use low- and medium-enthalpy energy totaling 2560.0 MWth of installed capacity that yielded 689.2 ktoe in 2008 and 3 countries Hungary, Italy and France totaling 480.3 ktoe. Very low-enthalpy energy concerns the exploitation of shallow geothermal resources using geothermal heat pumps. In 2008, 114452 ground heat pumps were sold in Europe. At the end of 2008, the installed capacity was 8955.4 MWth (16.5% up on 2007 level, it represented 785206 pumps. Over one million ground heat pumps are expected to be operating in 2010 in Europe. (A.C.)

  13. Preliminary Electrical Designs for CTEX and AFIT Satellite Ground Station

    Science.gov (United States)

    2010-03-01

    Examples of these sources are gas-discharge lamps, neon signs, or putting different salt compounds into an open flame. Along with the colored...light onto a collector . The collector for the initial imager is a simple Focal Plane Array (FPA) imager. 37 AFIT PhD candidate Randy Bostick’s research...shaft for Tx/Rx Horizontal shaft for VHF/UHF antenna mounts 1 10 foot parabolic S-band dish (Skyvision 1512015) Receives down link signals in S-band 1

  14. Army Transitions Hybrid Electric Technology to FCS Manned Ground Vehicles

    Science.gov (United States)

    2007-12-01

    completely new way of maneuvering on the battlefield. The system’s advanced energy storage, power generation, regenerative braking and power management... categories , including mixing, coat- ing and winding; electrolyte filling; cir- cuit breaker bussing and closing; electri- cal formation; and battery

  15. electric vehicle

    Directory of Open Access Journals (Sweden)

    W. R. Lee

    1999-01-01

    Full Text Available A major problem facing battery-powered electric vehicles is in their batteries: weight and charge capacity. Thus, a battery-powered electric vehicle only has a short driving range. To travel for a longer distance, the batteries are required to be recharged frequently. In this paper, we construct a model for a battery-powered electric vehicle, in which driving strategy is to be obtained such that the total travelling time between two locations is minimized. The problem is formulated as an optimization problem with switching times and speed as decision variables. This is an unconventional optimization problem. However, by using the control parametrization enhancing technique (CPET, it is shown that this unconventional optimization is equivalent to a conventional optimal parameter selection problem. Numerical examples are solved using the proposed method.

  16. A fiber Bragg grating acceleration sensor for ground surveillance

    Science.gov (United States)

    Jiang, Shaodong; Zhang, Faxiang; Lv, Jingsheng; Ni, Jiasheng; Wang, Chang

    2017-10-01

    Ground surveillance system is a kind of intelligent monitoring equipment for detecting and tracking the ground target. This paper presents a fiber Bragg grating (FBG) acceleration sensor for ground surveillance, which has the characteristics of no power supply, anti-electromagnetic interference, easy large-scale networking, and small size. Which make it able to achieve the advantage of the ground surveillance system while avoiding the shortcoming of the electric sensing. The sensor has a double cantilever beam structure with a sensitivity of 1000 pm/g. Field experiment has been carried out on a flood beach to examine the sensor performance. The result shows that the detection distance on the walking of personnel reaches 70m, and the detection distance on the ordinary motor vehicle reaches 200m. The performance of the FBG sensor can satisfy the actual needs of the ground surveillance system.

  17. Effect of electrode shape on grounding resistances - Part 1

    DEFF Research Database (Denmark)

    Ingeman-Nielsen, Thomas; Tomaskovicova, Sonia; Dahlin, Torleif

    2016-01-01

    Electrode grounding resistance is a major factor affecting measurement quality in electric resistivity tomography (ERT) measurements for cryospheric applications. Still, little information is available on grounding resistances in the geophysical literature, mainly because it is difficult to measure....... The focus-one protocol is a new method for estimating single electrode grounding resistances by measuring the resistance between a single electrode in an ERT array and all the remaining electrodes connected in parallel. For large arrays, the measured resistance is dominated by the grounding resistance...... of the electrode under test, the focus electrode. We have developed an equivalent circuit model formulation for the resistance measured when applying the focus-one protocol. Our model depends on the individual grounding resistances of the electrodes of the array, the mutual resistances between electrodes...

  18. AB Levitator and Electricity Storage

    OpenAIRE

    Bolonkin, Alexander

    2007-01-01

    The author researched this new idea - support of flight by any aerial vehicles at significant altitude solely by the magnetic field of the planet. It is shown that current technology allows humans to create a light propulsion (AB engine) which does not depend on air, water or ground terrain. Simultaniosly, this revolutionary thruster is a device for the storage of electricity which is extracted and is replenished (during braking) from/into the storage with 100 percent efficiency. The relative...

  19. Electrical measurements during magnet construction

    International Nuclear Information System (INIS)

    Sintchak, G.; Ganetis, G.; Cottingham, G.

    1989-01-01

    Throughout the construction phase of the cold mass for SSC magnets, electrical tests are made to determine that no faults in the coil structure have developed. These tests include ones designed to measure turn-to-turn voltage hold-off, hypot tests to ground, coil resistance, and instrumentation checks. These various tests will be described and the test parameters that are used will be covered. 4 figs

  20. Electricity pricing

    International Nuclear Information System (INIS)

    Wijayatunga, P.D.C.

    1994-01-01

    Electricity pricing in most countries, especially in the developing world, has been determined by traditional accounting criteria where it raises revenue requirements to cover the operating costs and a return on past and future capital investments in possible power systems. The use of economic principles to improve the total economic efficiency in the electricity industry is discussed. Basic marginal cost theory, long run marginal costing (LRMC) cost categories and rating periods, marginal capacity costs, marginal energy costs, consumer costs, short run marginal costing (SRMC), marginal cost of fuel, marginal cost of network losses, market clearing price, value of unserved energy and network quality of supply cost are discussed

  1. Infrasonic induced ground motions

    Science.gov (United States)

    Lin, Ting-Li

    On January 28, 2004, the CERI seismic network recorded seismic signals generated by an unknown source. Our conclusion is that the acoustic waves were initiated by an explosive source near the ground surface. The meteorological temperature and effective sound speed profiles suggested existence of an efficient near-surface waveguide that allowed the acoustic disturbance to propagate to large distances. An explosion occurring in an area of forest and farms would have limited the number of eyewitnesses. Resolution of the source might be possible by experiment or by detailed analysis of the ground motion data. A seismo-acoustic array was built to investigate thunder-induced ground motions. Two thunder events with similar N-wave waveforms but different horizontal slownesses are chosen to evaluate the credibility of using thunder as a seismic source. These impulsive acoustic waves excited P and S reverberations in the near surface that depend on both the incident wave horizontal slowness and the velocity structure in the upper 30 meters. Nineteen thunder events were chosen to further investigate the seismo-acoustic coupling. The consistent incident slowness differences between acoustic pressure and ground motions suggest that ground reverberations were first initiated somewhat away from the array. Acoustic and seismic signals were used to generate the time-domain transfer function through the deconvolution technique. Possible non-linear interaction for acoustic propagation into the soil at the surface was observed. The reverse radial initial motions suggest a low Poisson's ratio for the near-surface layer. The acoustic-to-seismic transfer functions show a consistent reverberation series of the Rayleigh wave type, which has a systematic dispersion relation to incident slownesses inferred from the seismic ground velocity. Air-coupled Rayleigh wave dispersion was used to quantitatively constrain the near-surface site structure with constraints afforded by near-surface body

  2. Electrical Rectification

    Indian Academy of Sciences (India)

    user

    bio-mimetic systems. O w ing to the saturation of the e± ciency of sil- icon devices in electronics industry, m olecular electronics has gained trem endous im petus in re- cent tim es. T heoretical predictions and experi- m ental realizations of such system s have given birth to a ... their electrical conductance property and pos-.

  3. TOPEX ground data system

    Science.gov (United States)

    Rosell, S. N.; Yamarone, C. A., Jr.

    The TOPEX Project is a proposed oceanographic mission to measure the topography of the sea surface for a period of three years. This mission is sponsored by the National Aeronautics and Space Administration and managed by the Jet Propulsion Laboratory. Measurements of topography are used to study ocean currents, tides, bathymetry and the oceanic geoid. Several of the primary goals of this mission are to process and verify the altimetric data, and distribute them within days to the science investigators. This paper describes the TOPEX end-to-end ground data system. In addition to controlling the TOPEX satellite, the ground data system has been designed to minimize the time from data acquisition to science processing and data distribution. A centralized design supports the favorable response time of the system and also allows for operational efficiencies. Networking of real time and non-real time elements of the data system provides for more effective data processing.

  4. Ibis ground calibration

    International Nuclear Information System (INIS)

    Bird, A.J.; Barlow, E.J.; Tikkanen, T.; Bazzano, A.; Del Santo, M.; Ubertini, P.; Blondel, C.; Laurent, P.; Lebrun, F.; Di Cocco, G.; Malaguti, E.; Gabriele, M.; La Rosa, G.; Segreto, A.; Quadrini, E.; Volkmer, R.

    2003-01-01

    We present an overview of results obtained from IBIS ground calibrations. The spectral and spatial characteristics of the detector planes and surrounding passive materials have been determined through a series of calibration campaigns. Measurements of pixel gain, energy resolution, detection uniformity, efficiency and imaging capability are presented. The key results obtained from the ground calibration have been: - optimization of the instrument tunable parameters, - determination of energy linearity for all detection modes, - determination of energy resolution as a function of energy through the range 20 keV - 3 MeV, - demonstration of imaging capability in each mode, - measurement of intrinsic detector non-uniformity and understanding of the effects of passive materials surrounding the detector plane, and - discovery (and closure) of various leakage paths through the passive shielding system

  5. Ground motion effects

    Energy Technology Data Exchange (ETDEWEB)

    Blume, J A [John A. Blume and Associates, San Francisco, CA (United States)

    1969-07-01

    Ground motion caused by natural earthquakes or by nuclear explosion causes buildings and other structures to respond in such manner as possibly to have high unit stresses and to be subject to damage or-in some cases-collapse. Even minor damage may constitute a hazard to persons within or adjacent to buildings. The risk of damage may well be the governing restraint on the uses of nuclear energy for peaceful purposes. Theory is advanced regarding structural-dynamic response but real buildings and structures are complex, highly variable, and often difficult to model realistically. This paper discusses the state of knowledge, the art of damage prediction and safety precautions, and shows ground motion effects from explosions of underground nuclear devices in the continental United States including events Salmon, Gasbuggy, Boxcar, Faultless and Benham. (author)

  6. The LOFT Ground Segment

    DEFF Research Database (Denmark)

    Bozzo, E.; Antonelli, A.; Argan, A.

    2014-01-01

    targets per orbit (~90 minutes), providing roughly ~80 GB of proprietary data per day (the proprietary period will be 12 months). The WFM continuously monitors about 1/3 of the sky at a time and provides data for about ~100 sources a day, resulting in a total of ~20 GB of additional telemetry. The LOFT...... Burst alert System additionally identifies on-board bright impulsive events (e.g., Gamma-ray Bursts, GRBs) and broadcasts the corresponding position and trigger time to the ground using a dedicated system of ~15 VHF receivers. All WFM data are planned to be made public immediately. In this contribution...... we summarize the planned organization of the LOFT ground segment (GS), as established in the mission Yellow Book 1 . We describe the expected GS contributions from ESA and the LOFT consortium. A review is provided of the planned LOFT data products and the details of the data flow, archiving...

  7. Ground motion effects

    International Nuclear Information System (INIS)

    Blume, J.A.

    1969-01-01

    Ground motion caused by natural earthquakes or by nuclear explosion causes buildings and other structures to respond in such manner as possibly to have high unit stresses and to be subject to damage or-in some cases-collapse. Even minor damage may constitute a hazard to persons within or adjacent to buildings. The risk of damage may well be the governing restraint on the uses of nuclear energy for peaceful purposes. Theory is advanced regarding structural-dynamic response but real buildings and structures are complex, highly variable, and often difficult to model realistically. This paper discusses the state of knowledge, the art of damage prediction and safety precautions, and shows ground motion effects from explosions of underground nuclear devices in the continental United States including events Salmon, Gasbuggy, Boxcar, Faultless and Benham. (author)

  8. Atmospheric Electricity

    Science.gov (United States)

    Aplin, Karen; Fischer, Georg

    2018-02-01

    Electricity occurs in atmospheres across the Solar System planets and beyond, spanning spectacular lightning displays in clouds of water or dust, to more subtle effects of charge and electric fields. On Earth, lightning is likely to have existed for a long time, based on evidence from fossilized lightning strikes in ancient rocks, but observations of planetary lightning are necessarily much more recent. The generation and observations of lightning and other atmospheric electrical processes, both from within-atmosphere measurements, and spacecraft remote sensing, can be readily studied using a comparative planetology approach, with Earth as a model. All atmospheres contain charged molecules, electrons, and/or molecular clusters created by ionization from cosmic rays and other processes, which may affect an atmosphere's energy balance both through aerosol and cloud formation, and direct absorption of radiation. Several planets are anticipated to host a "global electric circuit" by analogy with the circuit occurring on Earth, where thunderstorms drive current of ions or electrons through weakly conductive parts of the atmosphere. This current flow may further modulate an atmosphere's radiative properties through cloud and aerosol effects. Lightning could potentially have implications for life through its effects on atmospheric chemistry and particle transport. It has been observed on many of the Solar System planets (Earth, Jupiter, Saturn, Uranus, and Neptune) and it may also be present on Venus and Mars. On Earth, Jupiter, and Saturn, lightning is thought to be generated in deep water and ice clouds, but discharges can be generated in dust, as for terrestrial volcanic lightning, and on Mars. Other, less well-understood mechanisms causing discharges in non-water clouds also seem likely. The discovery of thousands of exoplanets has recently led to a range of further exotic possibilities for atmospheric electricity, though lightning detection beyond our Solar System

  9. Electric fields and electrical insulation

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    2002-01-01

    The adoption of a field-theoretical approach to problems arising in the framework of electrical insulation is discussed with reference to six main topics, which have been addressed over the last 30 years. These include uniform field electrodes, Green's differential equation, electrode surface...... roughness, induced charge, electrostatic probes, and partial discharge transients, together with several follow-on aspects. Each topic is introduced and thereafter the progress achieved through the use of a field-theoretical approach is reviewed. Because the topics cover a wide spectrum of conditions......, it is amply demonstrated that such an approach can lead to significant progress in many areas of electrical insulation....

  10. Unmanned Ground Systems Roadmap

    Science.gov (United States)

    2011-07-01

    quality metric tracking history . 1.4.3.4 Technical Management Division The mission of the RS JPO Technical Management (Tech Mgt) Division is to...missions dictate radio capabilities. IP version 4 ( IPv4 ) is the common IP standard used on IP addressable devices of UGVs, however, Unmanned Ground...Systems Roadmap UNCLASSIFIED 26 UNCLASSIFIED July 2011 IPv4 addresses are projected to run out and UGV systems will need to migrate to IP version 6

  11. Ground System Survivability Overview

    Science.gov (United States)

    2012-03-27

    Avoidance Blast Mitigation Optimization Customer ILIR RDT&E Funding 5.0 % 0.5% GSS has a proven, technically proficient workforce that meets...Evaluation of Defensive-Aid Suites (ARMED) Common Automatic Fire Extinguishing System ( CAFES ) Transparent Armor Development Ground Combat Vehicle...Survey TRADOC (WFO, CNA, etc) Voice of the Customer Sy st em s En gi ne er in g Publish overarching MIL-STD, design guidelines, technical

  12. Crystalline beam ground state

    International Nuclear Information System (INIS)

    Wei, Jie; Li, Xiao-Ping; Sessler, A.M.

    1993-01-01

    In order to employ Molecular Dynamics method, commonly used in condensed matter physics, we have derived the equations of motion for a beam of charged particles in the rotating rest frame of the reference particle. We include in the formalism that the particles are confined by the guiding and focusing magnetic fields, and that they are confined in a conducting vacuum pipe while interacting with each other via a Coulomb force. Numerical simulations has been performed to obtain the equilibrium structure. The effects of the shearing force, centrifugal force, and azimuthal variation of the focusing strength are investigated. It is found that a constant gradient storage ring can not give a crystalline beam, but that an alternating-gradient (AG) structure can. In such a machine the ground state is, except for one-dimensional (1-D) crystals, time-dependent. The ground state is a zero entropy state, despite the time-dependent, periodic variation of the focusing force. The nature of the ground state, similar to that found by Rahman and Schiffer, depends upon the density and the relative focusing strengths in the transverse directions. At low density, the crystal is 1-D. As the density increases, it transforms into various kinds of 2-D and 3-D crystals. If the energy of the beam is higher than the transition energy of the machine, the crystalline structure can not be formed for lack of radial focusing

  13. Crystalline beam ground state

    International Nuclear Information System (INIS)

    Wei, Jie; Li, Xiao-Ping

    1993-01-01

    In order to employ molecular dynamics (MD) methods, commonly used in condensed matter physics, we have derived the equations of motion for a beam of charged particles in the rotating rest frame of the reference particle. We include in the formalism that the particles are confined by the guiding and focusing magnetic fields, and that they are confined in a conducting vacuum pipe while interacting with each other via a Coulomb force. Numerical simulations using MD methods has been performed to obtain the equilibrium crystalline beam structure. The effect of the shearing force, centrifugal force, and azimuthal variation of the focusing strength are investigated. It is found that a constant gradient storage ring can not give a crystalline beam, but that an alternating-gradient (AG) structure can. In such a machine the ground state is, except for one-dimensional (1-D) crystals, time dependent. The ground state is a zero entropy state, despite the time-dependent, periodic variation of the focusing force. The nature of the ground state, similar to that found by Schiffer et al. depends upon the density and the relative focusing strengths in the transverse directions. At low density, the crystal is 1-D. As the density increases, it transforms into various kinds of 2-D and 3-D crystals. If the energy of the beam is higher than the transition energy of the machine, the crystalline structure can not be formed for lack of radial focusing

  14. Crystalline beam ground state

    International Nuclear Information System (INIS)

    Wei, J.; Li, X.P.

    1993-01-01

    In order to employ the Molecular Dynamics method, commonly used in condensed matter physics, the authors have derived the equations of motion for a beam of charged particles in the rotating rest frame of the reference particle. They include in the formalism that the particles are confined by the guiding and focusing magnetic fields, and that they are confined in a conducting vacuum pipe while interacting with each other via a Coulomb force. Numerical simulations has been performed to obtain the equilibrium structure. The effects of the shearing force, centrifugal force, and azimuthal variation of the focusing strength are investigated. It is found that a constant gradient storage ring can not give a crystalline beam, but that an alternating-gradient (AG) structure can. In such a machine the ground state is, except for one-dimensional (1-D) crystals, time-dependent. The ground state is a zero entropy state, despite the time-dependent, periodic variation of the focusing force. The nature of the ground state, similar to that found by Rahman and Schiffer, depends upon the density and the relative focusing strengths in the transverse directions. At low density, the crystal is 1-D. As the density increases, it transforms into various kinds of 2-D and 3-D crystals. If the energy of the beam is higher than the transition energy of the machine, the crystalline structure can not be formed for lack of radial focusing

  15. 30 CFR 57.12027 - Grounding mobile equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding mobile equipment. 57.12027 Section 57.12027 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Electricity...

  16. 30 CFR 56.12027 - Grounding mobile equipment.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding mobile equipment. 56.12027 Section 56.12027 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Electricity § 56...

  17. Fringe integral equation method for a truncated grounded dielectric slab

    DEFF Research Database (Denmark)

    Jørgensen, Erik; Maci, S.; Toccafondi, A.

    2001-01-01

    The problem of scattering by a semi-infinite grounded dielectric slab illuminated by an arbitrary incident TMz polarized electric field is studied by solving a new set of “fringe” integral equations (F-IEs), whose functional unknowns are physically associated to the wave diffraction processes...

  18. Geo-Electrical Investigation for Groundwater Potential of Ihievbe ...

    African Journals Online (AJOL)

    ADOWIE PERE

    2017-12-10

    Dec 10, 2017 ... Keywords: Groundwater, Vertical Electrical Sounding, Fractured basement, prospectively ranking. The ease of ... magnetic, electromagnetic etc. Of all these ... ranking, to aid our interpretation and evaluation of the ground ...

  19. Electricity Bill

    International Nuclear Information System (INIS)

    Blair, A.; Beith, A.J.; Hardy, P.

    1989-01-01

    The first part of the debate, which lasted a total of about 7 hours, a verbatim report of the first five of which are included here, was about energy conservation. Several new clauses and amendments were discussed. One would place a duty on the new Director of the Energy Supply industry to promote the efficiency and conservation of energy, another would appoint a Deputy Director with responsibility for energy conservation, and the third would require targets of energy efficiency and pollution reduction to be achieved. This allowed discussion on energy saving by domestic thermal insulation, improved efficiency of heating and refrigeration units and on renewable energy sources especially world energy. The second part of the debate was about access to information regarding health and safety resulting from any activities of the electricity supply industry. The remainder of the debate concerned regional representation and the economics of the electricity supply industry. (UK)

  20. Electricity unplugged

    Science.gov (United States)

    Karalis, Aristeidis

    2009-02-01

    The judge was driving back late one cold winter night. Entering the garage, the battery-charging indicator in his wirelessly powered electric car came on. "Home at last," crossed his mind. He swiped his personal smartcard on the front-door detector to be let in. He heard a "charging" beep from his mobile phone. The blinking cursor on the half-finished e-mail on the laptop had been waiting all day on the side table. He picked the computer up and walked towards his desk. "Good evening, your honour. Your wirelessly heated robe," said the butler-robot as it approached from the kitchen. Putting on the electric garment, he sat on the medical desk chair. His artificial heart was now beating faster.

  1. Electricity supply

    International Nuclear Information System (INIS)

    Rezendes, V.S.

    1991-10-01

    This report focuses on the Securities and Exchange Commission's (SEC) administration of the Public Utility Holding Company Act of 1935, intended to protect the public, investors, and consumers from abuses associated with the control of electric and gas utility companies through the holding company structure. These abuses include subjecting subsidiary utilities to excessive charges for services, construction work, and materials; frustrating effective state regulation through the holding company structure; and overloading subsidiary utilities with debt to prevent voluntary rate reductions. GAO discusses industry changes during the past decade involving electric utility holding companies; SEC's regulatory response to such changes; and the relationship between SEC, the Federal Energy Regulatory Commission, and states in protecting consumer and investor interests in light of these changes

  2. Electric Car

    Science.gov (United States)

    1977-01-01

    NASA's Lewis Research Center undertook research toward a practical, economical battery with higher energy density. Borrowing from space satellite battery technology, Lewis came up with a nickel-zinc battery that promises longer life and twice the range of the lead-acid counterpart. Lewis researchers fabricated a prototype battery and installed it in an Otis P-500 electric utility van, using only the battery space already available and allowing battery weight equal to that of the va's conventional lead-acid battery

  3. Electrical deregulation

    International Nuclear Information System (INIS)

    Simpson, R.

    2001-01-01

    Deregulation in the electricity sector took effect on January 1, 2001 in Alberta. Business consumers discovered that their electricity rates had almost doubled in a one-month period. The government argued that it was the case of short term pain for long term gain. The intent of the deregulation is the lowering of prices through competition. This principle applies when the supply meets the demand, but when the demand exceeds the supply, prices increase. When initial plans were made for the deregulation of the sector, utilities did not invest huge amounts of capital to build new generation plants, as it was not known how they would fare in the deregulated environment. This situation was compounded by the fact that there was an economic boom around the same time in Alberta, adding to the demands made on the existing generation infrastructure (approximately 4 per cent per year over the past decade). At the moment, some resource developers such as Syncrude, Amoco, and Daishowa produce their own electricity and export their excess capacity to the provincial grid for general use. The rules of the deregulated market have been clarified and a number of utilities are planning new generation plants and facilities. TransAlta, EPCOR, and Enmax Corp. have announced plans to expand or build new coal-fired plants. Alberta has an estimated 35 billion tonnes of recoverable coal, and 25 million tonnes of coal were used in 1999 to produce 75 per cent of the electricity required in Alberta. Over the next ten years, 4,000 megawatts of new capacity is planned, representing a 50 per cent increase over current levels. AES Corporation, a Virginia power giant, has also announced plans to build a generator in Alberta

  4. Electrical cardioversion

    Science.gov (United States)

    Sucu, Murat; Davutoglu, Vedat; Ozer, Orhan

    2009-01-01

    External electrical cardioversion was first performed in the 1950s. Urgent or elective cardioversions have specific advantages, such as termination of atrial and ventricular tachycardia and recovery of sinus rhythm. Electrical cardioversion is life-saving when applied in urgent circumstances. The succcess rate is increased by accurate tachycardia diagnosis, careful patient selection, adequate electrode (paddles) application, determination of the optimal energy and anesthesia levels, prevention of embolic events and arrythmia recurrence and airway conservation while minimizing possible complications. Potential complications include ventricular fibrillation due to general anesthesia or lack of synchronization between the direct current (DC) shock and the QRS complex, thromboembolus due to insufficient anticoagulant therapy, non-sustained VT, atrial arrhythmia, heart block, bradycardia, transient left bundle branch block, myocardial necrosis, myocardial dysfunction, transient hypotension, pulmonary edema and skin burn. Electrical cardioversion performed in patients with a pacemaker or an incompatible cardioverter defibrillator may lead to dysfunction, namely acute or chronic changes in the pacing or sensitivity threshold. Although this procedure appears fairly simple, serious consequences might occur if inappropriately performed. PMID:19448376

  5. Simulated earthquake ground motions

    International Nuclear Information System (INIS)

    Vanmarcke, E.H.; Gasparini, D.A.

    1977-01-01

    The paper reviews current methods for generating synthetic earthquake ground motions. Emphasis is on the special requirements demanded of procedures to generate motions for use in nuclear power plant seismic response analysis. Specifically, very close agreement is usually sought between the response spectra of the simulated motions and prescribed, smooth design response spectra. The features and capabilities of the computer program SIMQKE, which has been widely used in power plant seismic work are described. Problems and pitfalls associated with the use of synthetic ground motions in seismic safety assessment are also pointed out. The limitations and paucity of recorded accelerograms together with the widespread use of time-history dynamic analysis for obtaining structural and secondary systems' response have motivated the development of earthquake simulation capabilities. A common model for synthesizing earthquakes is that of superposing sinusoidal components with random phase angles. The input parameters for such a model are, then, the amplitudes and phase angles of the contributing sinusoids as well as the characteristics of the variation of motion intensity with time, especially the duration of the motion. The amplitudes are determined from estimates of the Fourier spectrum or the spectral density function of the ground motion. These amplitudes may be assumed to be varying in time or constant for the duration of the earthquake. In the nuclear industry, the common procedure is to specify a set of smooth response spectra for use in aseismic design. This development and the need for time histories have generated much practical interest in synthesizing earthquakes whose response spectra 'match', or are compatible with a set of specified smooth response spectra

  6. Ground System Extensibility Considerations

    Science.gov (United States)

    Miller, S. W.; Greene, E.

    2017-12-01

    The National Oceanic and Atmospheric Administration (NOAA) and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation civilian weather and environmental satellite system: the Joint Polar Satellite System (JPSS). The Joint Polar Satellite System will replace the afternoon orbit component and ground processing system of the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA. The JPSS satellites will carry a suite of sensors designed to collect meteorological, oceanographic, climatological and geophysical observations of the Earth. The ground processing system for JPSS is known as the JPSS Common Ground System (JPSS CGS). Developed and maintained by Raytheon Intelligence, Information and Services (IIS), the CGS is a multi-mission enterprise system serving NOAA, NASA and their national and international partners, such as NASA's Earth Observation System (EOS), NOAA's current POES, the Japan Aerospace Exploration Agency's (JAXA) Global Change Observation Mission - Water (GCOM-W1), and DoD's Defense Meteorological Satellite Program (DMSP). The CGS provides a wide range of support to a number of national and international missions, including command and control, mission management, data acquisition and routing, and environmental data processing and distribution. The current suite of CGS-supported missions has demonstrated the value of interagency and international partnerships to address global observation needs. With its established infrastructure and existing suite of missions, the CGS is extensible to a wider array of potential new missions. This paper will describe how the inherent scalability and extensibility of the CGS enables the addition of these new missions, with an eye on global enterprise needs in the 2020's and beyond.

  7. Ground penetrating radar

    CERN Document Server

    Daniels, David J

    2004-01-01

    Ground-penetrating radar has come to public attention in recent criminal investigations, but has actually been a developing and maturing remote sensing field for some time. In the light of recent expansion of the technique to a wide range of applications, the need for an up-to-date reference has become pressing. This fully revised and expanded edition of the best-selling Surface-Penetrating Radar (IEE, 1996) presents, for the non-specialist user or engineer, all the key elements of this technique, which span several disciplines including electromagnetics, geophysics and signal processing. The

  8. Predicting Ground Illuminance

    Science.gov (United States)

    Lesniak, Michael V.; Tregoning, Brett D.; Hitchens, Alexandra E.

    2015-01-01

    Our Sun outputs 3.85 x 1026 W of radiation, of which roughly 37% is in the visible band. It is directly responsible for nearly all natural illuminance experienced on Earth's surface, either in the form of direct/refracted sunlight or in reflected light bouncing off the surfaces and/or atmospheres of our Moon and the visible planets. Ground illuminance, defined as the amount of visible light intercepting a unit area of surface (from all incident angles), varies over 7 orders of magnitude from day to night. It is highly dependent on well-modeled factors such as the relative positions of the Sun, Earth, and Moon. It is also dependent on less predictable factors such as local atmospheric conditions and weather.Several models have been proposed to predict ground illuminance, including Brown (1952) and Shapiro (1982, 1987). The Brown model is a set of empirical data collected from observation points around the world that has been reduced to a smooth fit of illuminance against a single variable, solar altitude. It provides limited applicability to the Moon and for cloudy conditions via multiplicative reduction factors. The Shapiro model is a theoretical model that treats the atmosphere as a three layer system of light reflectance and transmittance. It has different sets of reflectance and transmittance coefficients for various cloud types.In this paper we compare the models' predictions to ground illuminance data from an observing run at the White Sands missile range (data was obtained from the United Kingdom's Meteorology Office). Continuous illuminance readings were recorded under various cloud conditions, during both daytime and nighttime hours. We find that under clear skies, the Shapiro model tends to better fit the observations during daytime hours with typical discrepancies under 10%. Under cloudy skies, both models tend to poorly predict ground illuminance. However, the Shapiro model, with typical average daytime discrepancies of 25% or less in many cases

  9. TFTR grounding scheme and ground-monitor system

    International Nuclear Information System (INIS)

    Viola, M.

    1983-01-01

    The Tokamak Fusion Test Reactor (TFTR) grounding system utilizes a single-point ground. It is located directly under the machine, at the basement floor level, and is tied to the building perimeter ground. Wired to this single-point ground, via individual 500 MCM insulated cables, are: the vacuum vessel; four toroidal field coil cases/inner support structure quadrants; umbrella structure halves; the substructure ring girder; radial beams and columns; and the diagnostic systems. Prior to the first machine operation, a ground-loop removal program was initiated. It required insulation of all hangers and supports (within a 35-foot radius of the center of the machine) of the various piping, conduits, cable trays, and ventilation systems. A special ground-monitor system was designed and installed. It actively monitors each of the individual machine grounds to insure that there are no inadvertent ground loops within the machine structure or its ground and that the machine grounds are intact prior to each pulse. The TFTR grounding system has proven to be a very manageable system and one that is easy to maintain

  10. The ground fault detection system for the Tore Supra toroidal pump limiter

    International Nuclear Information System (INIS)

    Zunino, K.; Cara, P.; Fejoz, P.; Hourtoule, J.; Loarer, T.; Pomaro, N.; Santagiustina, A.; Spuig, P.; Villecroze, F.

    2003-01-01

    The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding

  11. evaluation of electricity consumer's behaviour towards electricity ...

    African Journals Online (AJOL)

    Energy efficiency and sustainability: evaluation of electricity consumer's behaviour towards electricity usage and energy conservation. ... Remember me ... particularly about electricity consumer's attitudes, behaviour and practices with respect ...

  12. Quantitative evaluation of ground improvement by chemical grouting using electrical resistivity. Part 3. Applicability of evaluation of improved region by resistivity tomography; Denki hiteiko ni yoru yakueki chunyu kairyo koka no teiryoteki hyoka hoho. 3. Hiteiko tomography wo riyoshita jiban kairyo han`i hyoka hoho no tekiyosei

    Energy Technology Data Exchange (ETDEWEB)

    Komine, H. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1996-02-01

    This paper describes a method for evaluating grouting that is a means for improving the ground for excavation for building underground structures in urban areas. This is an effort for improving reliability, and evaluates the rate of filling of the water glass base chemical liquid injected for improving the ground utilizing the fact that this liquid is higher in conductivity than the soil or ground water. An experiment was conducted using a model ground so as to define the limit of applicability of this resistivity tomography by studying electrode arrangements and difference in resistivity between the grouted liquid and ground water. It was then found that the liquid-injected region is evaluated more accurately when the measuring electrodes are installed nearer to the region, that evaluation is satisfactorily accomplished when the region spans not less than 75% of the distance between the electrodes, that higher accuracy is expected when the difference in resistivity is greater between the grouted liquid and ground water, that evaluation is satisfactorily accomplished when the resistivity of the grouted liquid is not more than 10% of that of ground water, and that any grouting liquid usable for ground improvement in civil engineering in urban areas can be applied to any other grounds except where there is influence of seawater. 31 refs., 55 figs., 8 tabs.

  13. A thermal ground cloak

    International Nuclear Information System (INIS)

    Yang, Tianzhi; Wu, Qinghe; Xu, Weikai; Liu, Di; Huang, Lujun; Chen, Fei

    2016-01-01

    The thermal cloak has been a long-standing scientific dream of researchers and engineers. Recently thermal metamaterials with man-made micro-structure have been presented based on the principle of transformation optics (TO). This new concept has received considerable attention, which is a powerful tool for manipulating heat flux in thermal imaging systems. However, the inherent material singularity has long been a captivation of experimental realization. As an alternative method, the scattering-cancellation-based cloak (or bi-layer thermal cloak) has been presented to remove the singularity for achieving the same cloaking performance. Nevertheless, such strategy needs prerequisite knowledge (geometry and conductivity) of the object to be cloaked. In this paper, a new thermal ground cloak is presented to overcome the limitations. The device is designed, fabricated and measured to verify the thermal cloaking performance. We experimentally show that the remarkably low complexity of the device can fully and effectively be manipulated using realizable transformation thermal devices. More importantly, this thermal ground cloak is designed to exclude heat flux without knowing the information of the cloaked object. - Highlights: • We present the first thermal carpet cloak. • The carpet can thermally cloak any shaped object without knowing the properties of the object to be cloaked. • Excellent agreements between simulation and experiment are observed.

  14. Electrical transmission

    Energy Technology Data Exchange (ETDEWEB)

    Sayers, D P

    1960-05-01

    After briefly tracing the history of electricity transmission, trends in high voltage transmission and experiments being conducted on 650 kV are discussed. 5000 miles of the U.K. grid are operated at 132 kV and 1000 at 275 kV, ultimately to provide a super grid at 380 kV. Problems are insulation, radio interference and the cost of underground lines (16 times that of overhead lines). Also considered are the economics of the grid as a means of transporting energy and as a means of spreading the peak load over the power stations in the most efficient manner. Finally, the question of amenities is discussed.

  15. Cleanup Verification Package for the 118-B-1, 105-B Solid Waste Burial Ground

    International Nuclear Information System (INIS)

    Capron, J.M.

    2008-01-01

    This cleanup verification package documents completion of remedial action, sampling activities, and compliance criteria for the 118-B-1, 105-B Solid Waste Burial Ground. This waste site was the primary burial ground for general wastes from the operation of the 105-B Reactor and P-10 Tritium Separation Project and also received waste from the 105-N Reactor. The burial ground received reactor hardware, process piping and tubing, fuel spacers, glassware, electrical components, tritium process wastes, soft wastes and other miscellaneous debris

  16. Site Selection for Hvdc Ground Electrodes

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2014-12-01

    High-Voltage Direct Current (HVDC) transmission systems are composed of a bipole transmission line with a converter substation at each end. Each substation may be equipped with a HVDC ground electrode, which is a wide area (up to 1 km Ø) and deep (from 3 to 100m) electrical grounding. When in normal operation, the ground electrode will dissipate in the soil the unbalance of the bipole (~1.5% of the rated current). When in monopolar operation with ground return, the HVDC electrode will inject in the soil the nominal pole continuous current, of about 2000 to 3000 Amperes, continuously for a period up to a few hours. HVDC ground electrodes site selection is a work based on extensive geophysical and geological surveys, in order to attend the desired design requirements established for the electrodes, considering both its operational conditions (maximum soil temperature, working life, local soil voltage gradients etc.) and the interference effects on the installations located up to 50 km away. This poster presents the geophysical investigations conducted primarily for the electrodes site selection, and subsequently for the development of the crust resistivity model, which will be used for the interference studies. A preliminary site selection is conducted, based on general geographical and geological criteria. Subsequently, the geology of each chosen area is surveyed in detail, by means of electromagnetic/electrical geophysical techniques, such as magnetotelluric (deep), TDEM (near-surface) and electroresistivity (shallow). Other complementary geologic and geotechnical surveys are conducted, such as wells drilling (for geotechnical characterization, measurement of the water table depth and water flow, and electromagnetic profiling), and soil and water sampling (for measurement of thermal parameters and evaluation of electrosmosis risk). The site evaluation is a dynamic process along the surveys, and some sites will be discarded. For the two or three final sites, the

  17. [Electrical storm].

    Science.gov (United States)

    Barnay, C; Taieb, J; Morice, R

    2007-11-01

    Electrical storm is defined as repeated occurrence of severe ventricular arrhythmias requiring multiple cardioversions, two or more or three or more following different studies. The clinical aspect can sometimes be made of multiple, self aggravating, life threatening accesses. There are three main clinical circumstances of occurrence: in patients equipped with intracardiac defibrillators, during the acute phase of myocardial infarction and in Brugada syndrome. 10 to 15% of patients with cardiac defibrillators are subject to electrical storms in a period of two years. The causative arrhythmia is most often ventricular tachycardia than ventricular fibrillation, especially in secondary prevention and if the initial arrhythmias justifying the device was a ventricular tachycardia. Precipitaing factors are present in one third of cases, mainly acute heart failure, ionic disorders and arrhythmogenic drugs. Predictive factors are age, left ventricular ejection fractionelectrical shock in 50% of cases, antitachycardi stimulation in 30% and in 20% by association of the two. Treatment, after elimination of inappropriate shocks, is mainly based on beta-blockers and amiodarone, class I antiarrhythmics, lidocaïne or bretylium in some cases, and sedation pushed to general anesthesia in some cases. Radio-frequency ablation and even heart transplantation have been proposed in extreme cases. Quinidine has been proved efficient in cases of Brugada syndrome.

  18. Electric crossover

    International Nuclear Information System (INIS)

    Schuster, R.M.; Luria, N.G.

    1977-01-01

    This invention concerns an electric crossover that makes a steam and pressure-tight seal for a conductor crossing two separate walls of a nuclear reactor vessel that seismic tremors or thermal expansion of the walls and conductor subject to relative displacements. The conductors, that have to cross the vessels, are fixed to the walls of the vessel in crossover systems fitted in crossover channels made in the walls of the vessel on their initial manufacture. The separate walls of the vessel move independently when they undergo an earth tremor or a temperature change between the walls or between the conductor. This shift can damage the conductor or the crossover system and this could give rise to cause steam or other materials to leak in the reactor should leaks occur in the primary system. Furthermore, in the case of medium or high power conductors, which are relatively rigid, the non-alignment of the crossover channels can bring about awkward stresses in the conductors or their protective sheathing. The aims of this invention are fulfilled by designing an electric crossover to pass at least one conductor through the two separate walls of a vessels, that includes an initial sub-assembly crossover, secured in a leak-tight manner to the first wall and a second sub-sessembly crossover in sliding or rolling contact with the second wall, whilst forming a leak-tight seal with it [fr

  19. Electric moments in molecule interferometry

    International Nuclear Information System (INIS)

    Eibenberger, Sandra; Gerlich, Stefan; Arndt, Markus; Tuexen, Jens; Mayor, Marcel

    2011-01-01

    We investigate the influence of different electric moments on the shift and dephasing of molecules in a matter wave interferometer. Firstly, we provide a quantitative comparison of two molecules that are non-polar yet polarizable in their thermal ground state and that differ in their stiffness and response to thermal excitations. While C 25 H 20 is rather rigid, its larger derivative C 49 H 16 F 52 is additionally equipped with floppy side chains and vibrationally activated dipole moment variations. Secondly, we elucidate the role of a permanent electric dipole momentby contrasting the quantum interference pattern of a (nearly) non-polar and a polar porphyrin derivative. We find that a high molecular polarizability and even sizeable dipole moment fluctuations are still well compatible with high-contrast quantum interference fringes. The presence of permanent electric dipole moments, however, can lead to a dephasing and rapid degradation of the quantum fringe pattern already at moderate electric fields. This finding is of high relevance for coherence experiments with large organic molecules, which are generally equipped with strong electric moments.

  20. Ground Vehicle Convoying

    Science.gov (United States)

    Gage, Douglas W.; Pletta, J. Bryan

    1987-01-01

    Initial investigations into two different approaches for applying autonomous ground vehicle technology to the vehicle convoying application are described. A minimal capability system that would maintain desired speed and vehicle spacing while a human driver provided steering control could improve convoy performance and provide positive control at night and in inclement weather, but would not reduce driver manpower requirements. Such a system could be implemented in a modular and relatively low cost manner. A more capable system would eliminate the human driver in following vehicles and reduce manpower requirements for the transportation of supplies. This technology could also be used to aid in the deployment of teleoperated vehicles in a battlefield environment. The needs, requirements, and several proposed solutions for such an Attachable Robotic Convoy Capability (ARCC) system will be discussed. Included are discussions of sensors, communications, computers, control systems and safety issues. This advanced robotic convoy system will provide a much greater capability, but will be more difficult and expensive to implement.

  1. Common Ground and Delegation

    DEFF Research Database (Denmark)

    Dobrajska, Magdalena; Foss, Nicolai Juul; Lyngsie, Jacob

    preconditions of increasing delegation. We argue that key HR practices?namely, hiring, training and job-rotation?are associated with delegation of decision-making authority. These practices assist in the creation of shared knowledge conditions between managers and employees. In turn, such a ?common ground......? influences the confidence with which managers delegate decision authority to employees, as managers improve their knowledge of the educational background, firm-specific knowledge, and perhaps even the possible actions of those to whom they delegate such authority. To test these ideas, we match a large......-scale questionnaire survey with unique population-wide employer-employee data. We find evidence of a direct and positive influence of hiring decisions (proxied by common educational background), and the training and job rotation of employees on delegation. Moreover, we find a positive interaction between common...

  2. Electric-Drive Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Septon, Kendall K [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-11

    Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).

  3. Electric-Drive Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-09-01

    Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).

  4. GROUNDED THEORY METHODOLOGY and GROUNDED THEORY RESEARCH in TURKEY

    OpenAIRE

    ARIK, Ferhat; ARIK, Işıl Avşar

    2016-01-01

    This research discusses the historical development of the Grounded Theory Methodology, which is one of the qualitative research method, its transformation over time and how it is used as a methodology in Turkey. The Grounded Theory which was founded by Strauss and Glaser, is a qualitative methodology based on inductive logic to discover theories in contrast with the deductive understanding which is based on testing an existing theory in sociology. It is possible to examine the Grounded Theory...

  5. Electrical bushing for a superconductor element

    Science.gov (United States)

    Mirebeau, Pierre; Lallouet, Nicolas; Delplace, Sebastien; Lapierre, Regis

    2010-05-04

    The invention relates to an electrical bushing serving to make a connection at ambient temperature to a superconductor element situated in an enclosure at cryogenic temperature. The electrical bushing passes successively through an enclosure at intermediate temperature between ambient temperature and cryogenic temperature, and an enclosure at ambient temperature, and it comprises a central electrical conductor surrounded by an electrically insulating sheath. According to the invention, an electrically conductive screen connected to ground potential surrounds the insulating sheath over a section that extends from the end of the bushing that is in contact with the enclosure at cryogenic temperature at least as far as the junction between the enclosure at intermediate temperature and the enclosure at ambient temperature. The invention is more particularly applicable to making a connection to a superconductor cable.

  6. Thunderstorm ground enhancements (TGEs) abruptly terminated by negative cloud-to-ground lightnings

    International Nuclear Information System (INIS)

    Chilingarian, A.; Hovsepyan, G.; Khanikyanc, G.; Pokhsraryan, D.; Soghomonyan, S.

    2016-01-01

    The relationship of lightnings and particle fluxes in the thunderclouds is not fully understood to date. Using the particle beams (the so-called Thunderstorm Ground Enhancements – TGEs) generated in the lower part of clouds by the strong electric fields as a probe, we investigate the characteristics of the related atmospheric discharges. The well-known effect of the TGE dynamics is the abrupt termination of the particle flux. We demonstrate that among 12 atmospheric discharges that abruptly terminated TGE all are the negative cloud-to-ground lightnings. The flux termination and lightning occurred at one and the same second. With new precise electronics on millisecond time scales we can see that particle flux decline occurred simultaneously with abrupt increase of electrostatic field after the return stroke of the lightning. Therefore, the declining of particle flux is connected with rearranging of charge centers in the cloud involving removal of the Lower Positive Charged Region (LPCR). (author)

  7. Electricity privatisation

    International Nuclear Information System (INIS)

    Dobson, Frank; Skinner, Dennis; Marshall, John

    1990-01-01

    In this amendment debate about the privatisation of the electricity supply, the opposition develops a number of themes detracting from the government's policy in this matter. It is felt that the industry is being sold off much too cheaply, at about one third of its value based on previous audits. Measures to prevent environmental damage are not likely to be implemented as they would reduce profits. Fuel reserves are in danger of depletion, especially natural gas. Coal imports will increase with accompanying threats to the balance of payments. Lastly, it is argued that very large sums of money are being paid unnecessarily to City Analysts and that big business and M.P.s are acting immorally in extracting money from what should be a publicly owned utility. The amendment was defeated by 298 to 186. (author)

  8. Electric conductivity of TlInTe2 monocrystal in strong electric fields

    International Nuclear Information System (INIS)

    Zarbaliev, M.M.; Godzhaev, Eh.M.; Gadzhiev, V.A.

    1980-01-01

    Electric condUctivity of the TlInTe 2 single crystal in strong electric fields has been studied in the range of 77-300 K. The electron part of the TlInTe 2 dielectric constant has been found to be 4. The dependence of the activation energy of current carriers on the electric field strength is constructed and the value of the activation energy of current carriers in the absence of an electric field is determined by the extrapolation method. The results of the experiments are in good agreement with the Frenkel-Pool theory, and this affords grounds for asserting that the obtained dependences of electric conductivity on temperature and the electric field strength are defined by variation in the current carrier concentration due to action of the thermal-electron ionization mechanism

  9. HVDC Ground Electrodes and Tectonic Setting

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2017-12-01

    Ground electrodes in HVDC transmission are huge grounding systems for the DC part of the converter substation, about 1 km wide, sized to inject in the ground DC currents up to 3.5 kA. This work presents an analysis of how the tectonic setting at converter substation location is determinant for the search of the best electrode location (Site Selection) and on its design and performance. It will briefly present the author experience on HVDC electrode design, summarized as follows: Itaipu - Foz do Iguaçu electrodes (transmitter side) located in the middle of Paraná Sedimentary Basin, and Ibiúna electrodes (receiving side) on the border of the basin, 6 km from the geological strike, where the crystalline basement outcrops in São Paulo state; Madeira River - North electrodes (transmitting side) located on the Northwest border of South Amazon Craton, where the crystalline basement is below a shallow sediments layer, and South electrodes (receiving side) located within Paraná Sedimentary Basin; Chile - electrodes located on the Andean forearc, where the Nazca Plate plunges under the South American Plate; Kenya - Ethiopia - electrodes located in the African Rift; Belo Monte - North electrodes (transmitter side) located within the Amazonian Sedimentary Basin, about 35 km of its South border, and South electrodes (receiving side) within Paraná Sedimentary Basin (bipole 1) and on crystalline metamorphic terrain "Brasília Belt" (bipole 2). This diversity of geological conditions results on ground electrodes of different topologies and dimensions, with quite different electrical and thermal performances. A brief study of the geology of the converter stations regions, the so-called Desktop Study, allows for the preview of several important parameters for the site selection and design of the electrodes, such as localization, type, size and estimate of the interference area, which are important predictors of the investment to be made and indications of the design to be

  10. Methods of formation of efficiency indexes of electric power sources integration in regional electric power systems

    International Nuclear Information System (INIS)

    Marder, L.I.; Myzin, A.I.

    1993-01-01

    A methodic approach to the grounding of the integration process efficiency within the Unified electric power system is given together with the selection of a rational areal structure and concentration of power-generating source capacities. Formation of an economic functional according to alternative scenavies including the cost components taking account of the regional interests is considered. A method for estimation and distribution of the effect from electric power production integration in the power systems under new economic conditions is proposed

  11. Ground-water travel time

    International Nuclear Information System (INIS)

    Bentley, H.; Grisak, G.

    1985-01-01

    The Containment and Isolation Working Group considered issues related to the postclosure behavior of repositories in crystalline rock. This working group was further divided into subgroups to consider the progress since the 1978 GAIN Symposium and identify research needs in the individual areas of regional ground-water flow, ground-water travel time, fractional release, and cumulative release. The analysis and findings of the Ground-Water Travel Time Subgroup are presented

  12. Regional ground-water system

    International Nuclear Information System (INIS)

    Long, J.

    1985-01-01

    The Containment and Isolation Working Group considered issues related to the postclosure behavior of repositories in crystalline rock. This working group was further divided into subgroups to consider the progress since the 1978 GAIN Symposium and identify research needs in the individual areas of regional ground-water flow, ground-water travel time, fractional release, and cumulative release. The analysis and findings of the Ground-Water Regime Subgroup are presented

  13. Chapter A6. Section 6.3. Specific Electrical Conductance

    Science.gov (United States)

    Radtke, Dean B.; Davis, Jerri V.; Wilde, Franceska D.

    2005-01-01

    Electrical conductance is a measure of the capacity of a substance to conduct an electrical current. The specific electrical conductance (conductivity) of water is a function of the types and quantities of dissolved substances it contains, normalized to a unit length and unit cross section at a specified temperature. This section of the National Field Manual (NFM) describes U.S. Geological Survey (USGS) guidance and protocols for measurement of conductivity in ground and surface waters.

  14. Power quality considerations for nuclear spectroscopy applications: Grounding

    Science.gov (United States)

    García-Hernández, J. M.; Ramírez-Jiménez, F. J.; Mondragón-Contreras, L.; López-Callejas, R.; Torres-Bribiesca, M. A.; Peña-Eguiluz, R.

    2013-11-01

    Traditionally the electrical installations are designed for supplying power and to assure the personnel safety. In nuclear analysis laboratories, additional issues about grounding also must be considered for proper operation of high resolution nuclear spectroscopy systems. This paper shows the traditional ways of grounding nuclear spectroscopy systems and through different scenarios, it shows the effects on the more sensitive parameter of these systems: the energy resolution, it also proposes the constant monitoring of a power quality parameter as a way to preserve or to improve the resolution of the systems, avoiding the influence of excessive extrinsic noise.

  15. Temporal variation of uranium in ground water with conductivity

    International Nuclear Information System (INIS)

    Pulhani, Vandana; Chaudhury, Moushumi D.; Jha, S.K.; Tripathi, R.M.

    2015-01-01

    The concentration of uranium in drinking water sources is a matter of health concern since it has been proved to be chemo-toxic to humans. Uranium being a more soluble actinide is also very mobile in the environment. The effect of water quality parameters and their co-relation to uranium content in the water is an interesting study to understand and predict its behavior in ground water and subsequently to judge the hazard posed. Hence studies on spatial and temporal variation of uranium concentration with electrical conductivity, pH, total dissolved solids and salinity in ground water was carried out. (author)

  16. Application of Low Voltage High Resistance Grounding in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Choong-Koo Chang

    2016-02-01

    Full Text Available Most nuclear power plants now utilize solid grounded low voltage systems. For safety and reliability reasons, the low voltage (LV high resistance grounding (HRG system is also increasingly used in the pulp and paper, petroleum and chemical, and semiconductor industries. Fault detection is easiest and fastest with a solidly grounded system. However, a solidly grounded system has many limitations such as severe fault damage, poor reliability on essential circuits, and electrical noise caused by the high magnitude of ground fault currents. This paper will briefly address the strengths and weaknesses of LV grounding systems. An example of a low voltage HRG system in the LV system of a nuclear power plant will be presented. The HRG system is highly recommended for LV systems of nuclear power plants if sufficient considerations are provided to prevent nuisance tripping of ground fault relays and to avoid the deterioration of system reliability.

  17. Characteristics of lightning leader propagation and ground attachment

    Science.gov (United States)

    Jiang, Rubin; Qie, Xiushu; Wang, Zhichao; Zhang, Hongbo; Lu, Gaopeng; Sun, Zhuling; Liu, Mingyuan; Li, Xun

    2015-12-01

    The grounding process and the associated leader behavior were analyzed by using high-speed video record and time-correlated electric field change for 37 natural negative cloud-to-ground flashes. Weak luminous grounded channel was recognized below the downward leader tip in the frame preceding the return stroke, which is inferred as upward connecting leader considering the physical process of lightning attachment, though not directly confirmed by sequential frames. For stepped leader-first return strokes, the upward connecting leaders tend to be induced by those downward leader branches with brighter luminosity and lower channel tip above ground, and they may accomplish the attachment with great possibility. The upward connecting leaders for 2 out of 61 leader-subsequent stroke sequences were captured in the frame prior to the return stroke, exhibiting relatively long channel lengths of 340 m and 105 m, respectively. The inducing downward subsequent leaders were of the chaotic type characterized by irregular electric field pulse train with duration of 0.2-0.3 ms. The transient drop of the high potential difference between stepped leader system and ground when the attachment occurred would macroscopically terminate the propagation of those ungrounded branches while would not effectively prevent the development of the existing space stem systems in the low-conductivity streamer zone apart from the leader tip. When the ungrounded branches are of poor connection with the main stroke channel, their further propagation toward ground would be feasible. These two factors may contribute to the occurrence of multiple grounding within the same leader-return stroke sequence.

  18. Ground-fault protection of insulated high-voltage power networks in mines

    Energy Technology Data Exchange (ETDEWEB)

    Pudelko, H

    1976-09-01

    Safety of power networks is discussed in underground black coal mines in Poland. Safety in mines with a long service life was compared with safety in mines constructed since 1950. Power networks and systems protecting against electric ground-faults in the 2 mine groups are comparatively evaluated. Systems for protection against electric ground-faults in mine high-voltage networks with an insulated star point of the transformer are characterized. Fluctuations of resistance of electrical insulation under conditions of changing load are analyzed. The results of analyses are given in 14 diagrams. Recommendations for design of systems protecting against electric ground-faults in 6 kV mine power systems are made. 7 references.

  19. Ground Attenuation of Railroad Noise

    DEFF Research Database (Denmark)

    Makarewicz, R.; Rasmussen, Karsten Bo; Kokowski, P.

    1996-01-01

    The influence of ground effect on railroad noise is described using the concept of the peak A-weighted sound exposure level, and A-weighted sound exposure level. The train is modelled by a continuous line of incoherent point sources that have a cosine directivity. The ground effect is included...

  20. Grounding Damage to Conventional Vessels

    DEFF Research Database (Denmark)

    Lützen, Marie; Simonsen, Bo Cerup

    2003-01-01

    The present paper is concerned with rational design of conventional vessels with regard to bottom damage generated in grounding accidents. The aim of the work described here is to improve the design basis, primarily through analysis of new statistical data for grounding damage. The current regula...

  1. Ground-based photo monitoring

    Science.gov (United States)

    Frederick C. Hall

    2000-01-01

    Ground-based photo monitoring is repeat photography using ground-based cameras to document change in vegetation or soil. Assume those installing the photo location will not be the ones re-photographing it. This requires a protocol that includes: (1) a map to locate the monitoring area, (2) another map diagramming the photographic layout, (3) type and make of film such...

  2. Electrical equipment design library

    International Nuclear Information System (INIS)

    1994-01-01

    This book guides the design supervision, construction order for electrical equipment. The contents of this library are let's use electricity like this, leading-in-pole and casual power, electric pole install below 300KVA, electric pole install below 301∼1000KVA, electric pole install exceed 1000KVA, rooftop install exceed 1000KVA, CUBICLE type, 154KV services. It adds an appendix.

  3. On Grounding of Fast Ships

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup; Pedersen, Preben Terndrup

    1997-01-01

    The paper deals with analysis of grounding of high-speed crafts. It is the purpose to present a comprehensive mathematical model for calculation of the overall dynamic ship response during grounding. This procedure is applied to derive the motions, the time varying sectional forces and the local...... loads during grounding on plane, sloping, sandy bottoms for six different designs of fast monohull ships made from steel, aluminium or GRP sandwich materials. The results show that the effect of the hull flexibility is to reduce the overall dynamic sectional loads on the hull girder. The considered...... numerical examples also indicate that, even with impact speeds of 40 knots against a 1:10 sloping bottom, the global strength of the hull girder is not exceeded by the grounding induced loads.For the local deformation of high-speed ship hulls at the point of contact with the ground, the paper presents...

  4. Electrical design requirements for electrode boilers for nuclear plants

    International Nuclear Information System (INIS)

    Kempker, M.J.

    1979-01-01

    Medium-voltage steam electrode boilers, in the 20- to 50-MW range, have become an attractive alternative to comparable fossil-fueled boilers as a source of auxiliary steam during the startup and normal shutdown of nuclear power plants. The electrode boiler represents a favorable option because of environmental, fire protection, and licensing considerations. However, this electrical option brings some difficult design problems for which solutions are required in order to integrate the electrode boiler into the plant low resistance grounded power system. These considerations include the effects of an unbalanced electrode boiler on the performance of polyphase induction motors, boiler grounding for personnel safety, boiler neutral grounding, and ground relaying

  5. Regional analysis of ground and above-ground climate

    Science.gov (United States)

    1981-12-01

    The regional suitability of underground construction as a climate control technique is discussed with reference to (1) a bioclimatic analysis of long term weather data for 29 locations in the United States to determine appropriate above ground climate control techniques, (2) a data base of synthesized ground temperatures for the coterminous United States, and (3) monthly dew point ground temperature comparisons for identifying the relative likelihood of condensation from one region to another. It is concluded that the suitability of Earth tempering as a practice and of specific Earth sheltered design stereotypes varies geographically; while the subsurface almost always provides a thermal advantage on its own terms when compared to above ground climatic data, it can, nonetheless, compromise the effectiveness of other, regionally more important climate control techniques. Reviews of above and below ground climate mapping schemes related to human comfort and architectural design, and detailed description of a theoretical model of ground temperature, heat flow, and heat storage in the ground are included. Strategies of passive climate control are presented in a discussion of the building bioclimatic analysis procedure which has been applied in a computer analysis of 30 years of weather data for each of 20 locations in the United States.

  6. Regional analysis of ground and above-ground climate

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    The regional suitability of underground construction as a climate control technique is discussed with reference to (1) a bioclimatic analysis of long-term weather data for 29 locations in the United States to determine appropriate above ground climate control techniques, (2) a data base of synthesized ground temperatures for the coterminous United States, and (3) monthly dew point ground temperature comparisons for identifying the relative likelihood of condensation from one region to another. It is concluded that the suitability of earth tempering as a practice and of specific earth-sheltered design stereotypes varies geographically; while the subsurface almost always provides a thermal advantage on its own terms when compared to above ground climatic data, it can, nonetheless, compromise the effectiveness of other, regionally more important climate control techniques. Also contained in the report are reviews of above and below ground climate mapping schemes related to human comfort and architectural design, and detailed description of a theoretical model of ground temperature, heat flow, and heat storage in the ground. Strategies of passive climate control are presented in a discussion of the building bioclimatic analysis procedure which has been applied in a computer analysis of 30 years of weather data for each of 29 locations in the United States.

  7. Evaluation of stability of foundation ground during earthquake, (5)

    International Nuclear Information System (INIS)

    Nishi, Koh-ichi; Kanatani, Mamoru

    1987-01-01

    The Central Research Institute of Electric Power Industry advances the research on the method of evaluating foundation grounds from the standpoint of developing in-situ ground survey testing method and the method of evaluating mechanical properties in the studies on the technology for siting nuclear power stations on Quaternary grounds. The newly developed analytical technique on ground stability by the results of the analytical method for equivalent linear response was already reported. In this paper, the analytical method for nonlinear response to investigate into the more detailed behavior of ground due to strong earthquake motion is reported. In particular, the constitutive relation based on elastoplasticity was newly proposed in order to represent the deformation behavior during cyclic loading, and the examples of its application to the response of horizontally leveled sandy ground to earthquake are described. The dialatancy characteristics of soil are constituted by yield function, plastic potential functioin and hardening function. The material constants in proposed constitutive relation are easily determined by laboratory tests. One-dimensional response analysis was conducted, using the constitutive relation. (Kako, I.)

  8. Structural Composite Supercapacitors: Electrical and Mechanical Impact of Separators and Processing Conditions

    Science.gov (United States)

    2013-09-01

    Structural Composite Supercapacitors : Electrical and Mechanical Impact of Separators and Processing Conditions by Edwin B. Gienger, James F...Proving Ground, MD 21005-5066 ARL-TR-6624 September 2013 Structural Composite Supercapacitors : Electrical and Mechanical Impact of...2012 4. TITLE AND SUBTITLE Structural Composite Supercapacitors : Electrical and Mechanical Impact of Separators and Processing Conditions 5a

  9. The Electric Car Challenge.

    Science.gov (United States)

    Diehl, Brian E.

    1997-01-01

    Describes the Electric Car Challenge during which students applied methods of construction to build lightweight, strong vehicles that were powered by electricity. The activity required problem solving, sheet metal work, electricity, design, and construction skills. (JOW)

  10. Controlling Electrical Hazards

    National Research Council Canada - National Science Library

    1997-01-01

    ...). In general, OSHA's electrical standards are based on the National Fire Protection Associations Standard NFPA 70E, Electrical Safety Requirements for Employee Workplaces, and in turn, from the National Electrical Code (NEC...

  11. Agricultural Electricity. Electric Motors. Student Manual.

    Science.gov (United States)

    Benson, Robert T.

    Addressed to the student, this manual, which includes supplementary diagrams, discusses the following topics and principles: Electromagnetic fields, electromagnets, parts of an electric motor, determining speed of an electric motor, types of electric motors in common use (split-phase, capacitor, repulsion-induction, three-phase), the electric…

  12. Prices on electricity and transmission of electricity

    International Nuclear Information System (INIS)

    2003-01-01

    This publication contains data on prices of electric energy and transmission of electricity valid from 1 January 2003. The purpose is to illustrate the price changes on the electricity market in terms of prices for different customer categories. All companies holding network concessions for areas and all companies trading in electricity are included in this report, which is produced on an annual basis.The prices for transmission services 1 January 2003 were on the whole unchanged compared to the preceding year. For households the mean annual cost was SEK 882 for flats, SEK 4 335 for one- or two-family houses with electric heating and SEK 1 925 for those without electric heating. Electricity prices rose considerably on 1 January 2003 compared to the year before. The mean price per kWh for households with standard agreements was SEK 0.519 for deliveries to flats, SEK 0.447 for one- or two-family houses with electric heating and SEK 0.471 without electric heating. As a result, the mean annual cost increased by SEK 326 for flats, SEK 3 012 for one- or two-family houses with electric heating, and by SEK 774 for those houses without electric heating. The high costs of electricity may be explained in part by the development on the Nordic Power Exchange (Nord Pool), where the spot price increased by about 290 per cent during 2002 (1 USD is about 8 SEK)

  13. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  14. Practical Approach on Lightning and Grounding Protection System

    OpenAIRE

    Shan Jose Varghese

    2015-01-01

    Lightning Protection and Grounding of Electrical and Mechanical equipment’s for the Protection of the Human Beings, Structure of the building and equipment protection, safe working of the Worker at Industry as per my latest practical knowledge in the site environment in extreme climatic condition of low lying areas of the Gulf Region in the challenging projects. All the conductor calculation, Lightning Risk Factor calculations, all the system information regarding the ...

  15. Electrical engineer's reference book

    CERN Document Server

    Laughton, M A

    1985-01-01

    Electrical Engineer's Reference Book, Fourteenth Edition focuses on electrical engineering. The book first discusses units, mathematics, and physical quantities, including the international unit system, physical properties, and electricity. The text also looks at network and control systems analysis. The book examines materials used in electrical engineering. Topics include conducting materials, superconductors, silicon, insulating materials, electrical steels, and soft irons and relay steels. The text underscores electrical metrology and instrumentation, steam-generating plants, turbines

  16. DOE handbook electrical safety

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    Electrical Safety Handbook presents the Department of Energy (DOE) safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety guidance and information for DOE installations to effect a reduction or elimination of risks associated with the use of electrical energy. The objectives of this handbook are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  17. Electrical safety guidelines

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The Electrical Safety Guidelines prescribes the DOE safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety standards and guidance for DOE installations in order to affect a reduction or elimination of risks associated with the use of electrical energy. The objectives of these guidelines are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  18. Ground Control System Description Document

    International Nuclear Information System (INIS)

    Eric Loros

    2001-01-01

    The Ground Control System contributes to the safe construction and operation of the subsurface facility, including accesses and waste emplacement drifts, by maintaining the configuration and stability of the openings during construction, development, emplacement, and caretaker modes for the duration of preclosure repository life. The Ground Control System consists of ground support structures installed within the subsurface excavated openings, any reinforcement made to the rock surrounding the opening, and inverts if designed as an integral part of the system. The Ground Control System maintains stability for the range of geologic conditions expected at the repository and for all expected loading conditions, including in situ rock, construction, operation, thermal, and seismic loads. The system maintains the size and geometry of operating envelopes for all openings, including alcoves, accesses, and emplacement drifts. The system provides for the installation and operation of sensors and equipment for any required inspection and monitoring. In addition, the Ground Control System provides protection against rockfall for all subsurface personnel, equipment, and the engineered barrier system, including the waste package during the preclosure period. The Ground Control System uses materials that are sufficiently maintainable and that retain the necessary engineering properties for the anticipated conditions of the preclosure service life. These materials are also compatible with postclosure waste isolation performance requirements of the repository. The Ground Control System interfaces with the Subsurface Facility System for operating envelopes, drift orientation, and excavated opening dimensions, Emplacement Drift System for material compatibility, Monitored Geologic Repository Operations Monitoring and Control System for ground control instrument readings, Waste Emplacement/Retrieval System to support waste emplacement operations, and the Subsurface Excavation System

  19. Ground testing of an SP-100 prototypic reactor

    International Nuclear Information System (INIS)

    Motwani, K.; Pflasterer, G.R.; Upton, H.; Lazarus, J.D.; Gluck, R.

    1988-01-01

    SP-100 is a space power system which is being developed by GE to meet future space electrical power requirements. The ground testing of an SP-100 prototypic reactor system will be conducted at the Westinghouse Hanford Company site located at Richland, Washington. The objective of this test is to demonstrate the performance of a full scale prototypic reactor system, including the reactor, control system and flight shield. The ground test system is designed to simulate the flight operating conditions while meeting all the necessary nuclear safety requirements in a gravity environment. The goal of the reactor ground test system is to establish confidence in the design maturity of the SP-100 space reactor power system and resolve the technical issues necessary for the development of a flight mission design

  20. Ferro electricity from magnetic order by neutron measurement

    International Nuclear Information System (INIS)

    Kenzelmann, M.

    2009-01-01

    Magnetic insulators with competing exchange interactions can give rise to strong fluctuations and qualitatively new ground states. The proximity of such systems to quantum critical points can lead to strong cross-coupling between magnetic long-range order and the nuclear lattice. Case in point is a new class of multiferroic materials in which the magnetic and ferroelectric order parameters are directly coupled, and a magnetic field can suppress or switch the electric polarization [1]. Our neutron measurements reveal that ferro electricity is induced by magnetic order and emerges only if the magnetic structure creates a polar axis [2-5]. Our measurements provide evidence that commensurate magnetic order can produce ferro electricity with large electric polarization [6]. The spin dynamics and the field-temperature phase diagram of the ordered phases provide evidence that competing ground states are essential for ferro electricity. (author)

  1. Electricity shut-offs justified with those who refused to pay electricity rates

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    In its decision of December 18, 1980, the Freiburg Regional Court ordered the complainant, who had complained against electricity shut-offs, to pay the costs of the proceedings after having paid the withheld percentages of electricity rates. In doing so, the Regional Court onfirmed the adverse judgment of May 29, 1980, made by the Frankfurt Local Court ('et' 1980 p. 508). While the Local Courts of Frankfurt and Marburg objected to electricity shut-offs for being unreasonable, it is a widely-held view that one cannot deny the electricity supply utility the right to stop supplying those who boycott the payment of electricity rates. The Regional Court subscribed to this view, giving well-founded grounds. (orig./HSCH) [de

  2. Geophysics: Building E5481 decommissioning, Aberdeen Proving Ground

    International Nuclear Information System (INIS)

    Thompson, M.D.; McGinnis, M.G.; McGinnis, L.D.; Miller, S.F.

    1992-11-01

    Building E5481 is one of ten potentially contaminated sites in the Canal Creek and Westwood areas of the Edgewood section of Aberdeen Proving Ground examined by a geophysical team from Argonne National Laboratory in April and May of 1992. Noninvasive geophysical surveys, including magnetics, electrical resistivity, and ground-penetrating radar, were conducted around the perimeter of the building to guide a sampling program prior to decommissioning and dismantling. The building is located on the northern margin of a landfill that was sited in a wetland. The large number of magnetic sources surrounding the building are believed to be contained in construction fill that had been used to raise the grade. The smaller anomalies, for the most part, are not imaged with ground radar or by electrical profiling. A conductive zone trending northwest to southeast across the site is spatially related to an old roadbed. Higher resistivity areas in the northeast and east are probably representive of background values. Three high-amplitude, positive, rectangular magnetic anomalies have unknown sources. The features do not have equivalent electrical signatures, nor are they seen with radar imaging

  3. Geophysics: Building E5476 decommissiong, Aberdeen Proving Ground

    International Nuclear Information System (INIS)

    Miller, S.F.; Thompson, M.D.; McGinnis, M.G.; McGinnis, L.D.

    1992-11-01

    Building E5476 was one of ten potentially contaminated sites in the Canal Creek and Westwood areas of the Edgewood section of Aberdeen Proving Ground examined by a geophysical team from Argonne National Laboratory in April and May of 1992. Noninvasive geophysical surveys, including magnetics, electrical resistivity, and ground-penetrating radar, were conducted around the perimeter of the building to guide a sampling program prior to decommissioning and dismantling. The large number of magnetic sources surrounding the building are believed to be contained in construction fill. The smaller anomalies, for the most part, were not imaged with ground radar or by electrical profiling. Large magnetic anomalies near the southwest comer of the building are due to aboveground standpipes and steel-reinforced concrete. Two high-resistivity areas, one projecting northeast from the building and another south of the original structure, may indicate the presence of organic pore fluids in the subsurface. A conductive lineament protruding from the south wall that is enclosed by the southem, high-resistivity feature is not associated with an equivalent magnetic anomaly. Magnetic and electrical anomalies south of the old landfill boundary are probably not associated with the building. The boundary is marked by a band of magnetic anomalies and a conductive zone trending northwest to southeast. The cause of high resistivities in a semicircular area in the southwest comer, within the landfill area, is unexplained

  4. Ground-source heat pump case studies and utility programs

    Energy Technology Data Exchange (ETDEWEB)

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

    1995-04-01

    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  5. Electric engineering introduction

    International Nuclear Information System (INIS)

    An, Byeong Won; Eom, Sang Ho

    1999-03-01

    It is divided into nine chapters, which includes electricity theory such as structure of material and current, nature of electricity, static, magnetic force and magnetic attraction, attraction of current and a storage battery, electric circuit on a direct current circuit, single phase circuit and 3-phase current circuit electricity machine like DC generator, DC motor, alternator, electric transformer, single-phase induction motor, 3-phase induction motor, synchronous motor, synchro electric machine, semiconductor such as diode, transistor, FET, UJT, silicon symmetrical switch, electronic circuit like smoothing circuit and Bistable MV. circuit, automatic control, measurement of electricity, electric application and safety.

  6. Alternatives for ground water cleanup

    National Research Council Canada - National Science Library

    National Research Council Staff; Commission on Geosciences, Environment and Resources; Division on Earth and Life Studies; National Research Council; National Academy of Sciences

    .... Yet recent studies question whether existing technologies can restore contaminated ground water to drinking water standards, which is the goal for most sites and the result expected by the public...

  7. Integrated Ground Operations Demonstration Units

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of the AES Integrated Ground Operations Demonstration Units (IGODU) project is to demonstrate cost efficient cryogenic operations on a relevant...

  8. Imaging of Moving Ground Vehicles

    National Research Council Canada - National Science Library

    Rihaczek, A

    1996-01-01

    ... requires that use be made of the complex image. The yaw/pitch/roll/bounce/flex motion of a moving ground vehicle demands that different motion compensations be applied to different parts of the vehicle...

  9. Humic substances in ground waters

    International Nuclear Information System (INIS)

    Paxeus, N.; Allard, B.; Olofsson, U.; Bengtsson, M.

    1986-01-01

    The presence of naturally occurring complexing agents that may enhance the migration of disposed radionuclikes and thus facilitate their uptake by plantsis a problem associated with the underground disposal of radioactive wastes in bedrock. The main purpose of this work is to characterized humic substances from ground water and compare them with humic substances from surface water. The humic materials isolated from ground waters of a borehole in Fjaellveden (Sweden) were characterized by elemental and functional group analyses. Spectroscopic properties, molecular weight distributions as well as acid-base properties of the fulvic and humic fractions were also studied. The ground water humic substances were found to be quite similar in many respects (but not identical) to the Swedish surface water humics concentrated from the Goeta River but appeared to be quite different from the American ground water humics from Biscayne Florida Aquifer or Laramie Fox-Hills in Colorado. The physico-chemical properties of the isolated humic materials are discussed

  10. Ground Water and Climate Change

    Science.gov (United States)

    Taylor, Richard G.; Scanlon, Bridget; Doell, Petra; Rodell, Matt; van Beek, Rens; Wada, Yoshihide; Longuevergne, Laurent; Leblanc, Marc; Famiglietti, James S.; Edmunds, Mike; hide

    2013-01-01

    As the world's largest distributed store of fresh water, ground water plays a central part in sustaining ecosystems and enabling human adaptation to climate variability and change. The strategic importance of ground water for global water and food security will probably intensify under climate change as more frequent and intense climate extremes (droughts and floods) increase variability in precipitation, soil moisture and surface water. Here we critically review recent research assessing the impacts of climate on ground water through natural and human-induced processes as well as through groundwater-driven feedbacks on the climate system. Furthermore, we examine the possible opportunities and challenges of using and sustaining groundwater resources in climate adaptation strategies, and highlight the lack of groundwater observations, which, at present, limits our understanding of the dynamic relationship between ground water and climate.

  11. Ground Beef and Food Safety

    Science.gov (United States)

    ... 4 days. If frozen, it should keep its quality for about 4 months. When reheating fully cooked patties or casseroles containing ground beef, be sure the internal temperature reaches 165 °F (73.9 °C). Why ...

  12. Effect of Earth Ground and Environment on Body-Centric Communications in the MHz Band

    Directory of Open Access Journals (Sweden)

    Katsuyuki Fujii

    2012-01-01

    Full Text Available Body area network (BAN research, which uses the human body as a transmission channel, has recently attracted considerable attention globally. Zimmerman first advocated the idea in 1995. Illustrations of the electric field streamlines around the human body and wearable devices with electrodes were drawn. In the pictures, the electrodes of the wearable devices constitute a closed circuit with the human body and the earth ground. However, analysis of the circuit has not been conducted. In this study, we model the human body shunted to earth ground in a radio anechoic chamber to analyze the electric field strength around it and clarify the effect of earth ground during BAN run time. The results suggest that earth ground has little influence on the human body and wearable devices. Only when the human body is directly grounded, the electric field near the feet area will decrease. The input impedance of the transmitter is approximately the same, and the received open-circuit voltage and current of the receiver are also the same. In addition, we elucidate that stable communications can be established by developing a closed circuit using earth ground as return path. When the external electronic devices and human body are shunted to earth ground, the received open-circuit voltage and current increase.

  13. NASA HERMeS Hall Thruster Electrical Configuration Characterization

    Science.gov (United States)

    Peterson, Peter; Kamhawi, Hani; Huang, Wensheng; Yim, John; Herman, Daniel; Williams, George; Gilland, James; Hofer, Richard

    2016-01-01

    NASAs Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5 kW Technology Demonstration Unit-1 (TDU-1) Hall thruster has been the subject of extensive technology maturation in preparation for development into a flight ready propulsion system. Part of the technology maturation was to test the TDU-1 thruster in several ground based electrical configurations to assess the thruster robustness and suitability to successful in-space operation. The ground based electrical configuration testing has recently been demonstrated as an important step in understanding and assessing how a Hall thruster may operate differently in space compared to ground based testing, and to determine the best configuration to conduct development and qualification testing. This presentation will cover the electrical configuration testing of the TDU-1 HERMeS Hall thruster in NASA Glenn Research Centers Vacuum Facility 5. The three electrical configurations examined are the thruster body tied to facility ground, thruster floating, and finally the thruster body electrically tied to cathode common. The TDU-1 HERMeS was configured with two different exit plane boundary conditions, dielectric and conducting, to examine the influence on the electrical configuration characterization.

  14. Evaluation of multimodal ground cues

    DEFF Research Database (Denmark)

    Nordahl, Rolf; Lecuyer, Anatole; Serafin, Stefania

    2012-01-01

    This chapter presents an array of results on the perception of ground surfaces via multiple sensory modalities,with special attention to non visual perceptual cues, notably those arising from audition and haptics, as well as interactions between them. It also reviews approaches to combining...... synthetic multimodal cues, from vision, haptics, and audition, in order to realize virtual experiences of walking on simulated ground surfaces or other features....

  15. Electrical properties of Egyptian natural graphite

    International Nuclear Information System (INIS)

    El-Shazly, O.; El-Wahidy, E.F.; Elanany, N.; Saad, N.A.

    1992-06-01

    The electrical properties of Egyptian natural graphite flakes, obtained from the graphite schists of Wadi Bent, Eastern Desert, were measured. The flakes were ground and compressed into pellets. The standard four probe dc method was used to measure the temperature dependence of the electric resistivity from room temperature down to 12 K. The transverse and longitudinal magnetoresistance were measured in the low magnetic field range at temperatures 300 K, 77 K and 12 K. The transverse magnetoresistance data was used to estimate the average mobility, assuming a simple two-band model. (author). 20 refs, 4 figs, 1 tab

  16. Swiss electricity statistics 1996

    International Nuclear Information System (INIS)

    1997-01-01

    This detailed article discusses the following subjects: Survey of electricity supply in Switzerland in 1996; The Swiss electricity balance; Electric power generation; Electric power consumption; Generation, consumption and loads on selected days; Energy trade with other countries; Expansion capacities until 2003; Financial situation and appendix. (orig./RHM) [de

  17. Extreme-UV electrical discharge source

    Science.gov (United States)

    Fornaciari, Neal R.; Nygren, Richard E.; Ulrickson, Michael A.

    2002-01-01

    An extreme ultraviolet and soft x-ray radiation electric capillary discharge source that includes a boron nitride housing defining a capillary bore that is positioned between two electrodes one of which is connected to a source of electric potential can generate a high EUV and soft x-ray radiation flux from the capillary bore outlet with minimal debris. The electrode that is positioned adjacent the capillary bore outlet is typically grounded. Pyrolytic boron nitride, highly oriented pyrolytic boron nitride, and cubic boron nitride are particularly suited. The boron nitride capillary bore can be configured as an insert that is encased in an exterior housing that is constructed of a thermally conductive material. Positioning the ground electrode sufficiently close to the capillary bore outlet also reduces bore erosion.

  18. Electrical installations technology

    CERN Document Server

    Whitfield, J F

    1968-01-01

    Electrical Installations Technology covers the syllabus of the City and Guilds of London Institute course No. 51, the "Electricians B Certificate”. This book is composed of 15 chapters that deal with basic electrical science and electrical installations. The introductory chapters discuss the fundamentals and basic electrical principles, including the concept of mechanics, heat, magnetic fields, electric currents, power, and energy. These chapters also explore the atomic theory of electric current and the electric circuit, conductors, and insulators. The subsequent chapter focuses on the chemis

  19. The atmospheric electric global circuit. [thunderstorm activity

    Science.gov (United States)

    Kasemir, H. W.

    1979-01-01

    The hypothesis that world thunderstorm activity represents the generator for the atmospheric electric current flow in the earth atmosphere between ground and the ionosphere is based on a close correlation between the magnitude and the diurnal variation of the supply current (thunderstorm generator current) and the load current (fair weather air-earth current density integrated over the earth surface). The advantages of using lightning survey satellites to furnish a base for accepting or rejecting the thunderstorm generator hypothesis are discussed.

  20. Electricity economics. Production functions with electricity

    International Nuclear Information System (INIS)

    Hu, Zhaoguang; Hu, Zheng

    2013-01-01

    The first book studies on the economics of electricity consumption. Compares the sector production functions with electricity and the commercial production functions with electricity. Introduces the global E-GDP function, the European E-GDP function and 12 national E-GDP functions. Presents the gene characters of EAI production functions and E-GDP functions for USA to see why USA's economy is entering an up-industrialization period. Discusses China's economic growth by production functions with electricity. Electricity Economics: Production Functions with Electricity studies the production output from analyzing patterns of electricity consumption. Since electricity data can be used to measure scenarios of economic performance due to its accuracy and reliability, it could therefore also be used to help scholars explore new research frontiers that directly and indirectly benefits human society. Our research initially explores a similar pattern to substitute the Cobb-Douglas function with the production function with electricity to track and forecast economic activities. The book systematically introduces the theoretical frameworks and mathematical models of economics from the perspective of electricity consumption. The E-GDP functions are presented for case studies of more than 20 developed and developing countries. These functions also demonstrate substantial similarities between human DNA and production functions with electricity in terms of four major characteristics, namely replication, mutation, uniqueness, and evolution. Furthermore, the book includes extensive data and case studies on the U.S., China, Japan, etc. It is intended for scientists, engineers, financial professionals, policy makers, consultants, and anyone else with a desire to study electricity economics as well as related applications.

  1. Electricity economics. Production functions with electricity

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Zhaoguang [State Grid Energy Research Institute, Beijing (China); Hu, Zheng [Delaware Univ., Newark, DE (United States)

    2013-07-01

    The first book studies on the economics of electricity consumption. Compares the sector production functions with electricity and the commercial production functions with electricity. Introduces the global E-GDP function, the European E-GDP function and 12 national E-GDP functions. Presents the gene characters of EAI production functions and E-GDP functions for USA to see why USA's economy is entering an up-industrialization period. Discusses China's economic growth by production functions with electricity. Electricity Economics: Production Functions with Electricity studies the production output from analyzing patterns of electricity consumption. Since electricity data can be used to measure scenarios of economic performance due to its accuracy and reliability, it could therefore also be used to help scholars explore new research frontiers that directly and indirectly benefits human society. Our research initially explores a similar pattern to substitute the Cobb-Douglas function with the production function with electricity to track and forecast economic activities. The book systematically introduces the theoretical frameworks and mathematical models of economics from the perspective of electricity consumption. The E-GDP functions are presented for case studies of more than 20 developed and developing countries. These functions also demonstrate substantial similarities between human DNA and production functions with electricity in terms of four major characteristics, namely replication, mutation, uniqueness, and evolution. Furthermore, the book includes extensive data and case studies on the U.S., China, Japan, etc. It is intended for scientists, engineers, financial professionals, policy makers, consultants, and anyone else with a desire to study electricity economics as well as related applications.

  2. Prices on electricity and transmission of electricity

    International Nuclear Information System (INIS)

    2002-01-01

    This publication contains data on prices of electric energy and transmission of electricity valid on 1 January 2002. The purpose is to illustrate the price changes on the electricity market in terms of prices for different customer categories. All companies holding network concessions for areas and all companies trading in electricity are included in this report, which is produced on an annual basis. The prices for transmission services 1 January 2002 were on the whole unchanged compared to the preceding year. For households the mean annual cost was SEK 856 for flats, SEK 4,194 one- or two-family houses with electric heating and SEK 1,881 without electric heating. (1 SEK ∼ 0.1 USD). Electricity prices rose considerably on 1 January 2002 compared to the year before. The mean price per kWh for households according to standard agreement was SEK 0.356 for deliveries to flats, SEK 0.296 for apartments in one- or two-family houses with electric heating and SEK 0.316 without electric heating. That means that the mean annual cost increased by SEK 171 for flats. For one- or two-family houses with electric heating, costs increased by SEK 1,424, and by SEK 379 for those houses without electric heating. The high costs of electricity may be explained in part by the development on the Nordic Power Exchange (Nord Pool), where the spot price increased by 75 per cent during 2001. The price development for household customers during 1996-2002 is shown in a diagram

  3. Electric circuit theory applied electricity and electronics

    CERN Document Server

    Yorke, R

    1981-01-01

    Electric Circuit Theory provides a concise coverage of the framework of electrical engineering. Comprised of six chapters, this book emphasizes the physical process of electrical engineering rather than abstract mathematics. Chapter 1 deals with files, circuits, and parameters, while Chapter 2 covers the natural and forced response of simple circuit. Chapter 3 talks about the sinusoidal steady state, and Chapter 4 discusses the circuit analysis. The fifth chapter tackles frequency response of networks, and the last chapter covers polyphase systems. This book will be of great help to electrical

  4. A Unified Model of Cloud-to-Ground Lightning Stroke

    Science.gov (United States)

    Nag, A.; Rakov, V. A.

    2014-12-01

    The first stroke in a cloud-to-ground lightning discharge is thought to follow (or be initiated by) the preliminary breakdown process which often produces a train of relatively large microsecond-scale electric field pulses. This process is poorly understood and rarely modeled. Each lightning stroke is composed of a downward leader process and an upward return-stroke process, which are usually modeled separately. We present a unified engineering model for computing the electric field produced by a sequence of preliminary breakdown, stepped leader, and return stroke processes, serving to transport negative charge to ground. We assume that a negatively-charged channel extends downward in a stepped fashion through the relatively-high-field region between the main negative and lower positive charge centers and then through the relatively-low-field region below the lower positive charge center. A relatively-high-field region is also assumed to exist near ground. The preliminary breakdown pulse train is assumed to be generated when the negatively-charged channel interacts with the lower positive charge region. At each step, an equivalent current source is activated at the lower extremity of the channel, resulting in a step current wave that propagates upward along the channel. The leader deposits net negative charge onto the channel. Once the stepped leader attaches to ground (upward connecting leader is presently neglected), an upward-propagating return stroke is initiated, which neutralizes the charge deposited by the leader along the channel. We examine the effect of various model parameters, such as step length and current propagation speed, on model-predicted electric fields. We also compare the computed fields with pertinent measurements available in the literature.

  5. Modeled ground water age distributions

    Science.gov (United States)

    Woolfenden, Linda R.; Ginn, Timothy R.

    2009-01-01

    The age of ground water in any given sample is a distributed quantity representing distributed provenance (in space and time) of the water. Conventional analysis of tracers such as unstable isotopes or anthropogenic chemical species gives discrete or binary measures of the presence of water of a given age. Modeled ground water age distributions provide a continuous measure of contributions from different recharge sources to aquifers. A numerical solution of the ground water age equation of Ginn (1999) was tested both on a hypothetical simplified one-dimensional flow system and under real world conditions. Results from these simulations yield the first continuous distributions of ground water age using this model. Complete age distributions as a function of one and two space dimensions were obtained from both numerical experiments. Simulations in the test problem produced mean ages that were consistent with the expected value at the end of the model domain for all dispersivity values tested, although the mean ages for the two highest dispersivity values deviated slightly from the expected value. Mean ages in the dispersionless case also were consistent with the expected mean ages throughout the physical model domain. Simulations under real world conditions for three dispersivity values resulted in decreasing mean age with increasing dispersivity. This likely is a consequence of an edge effect. However, simulations for all three dispersivity values tested were mass balanced and stable demonstrating that the solution of the ground water age equation can provide estimates of water mass density distributions over age under real world conditions.

  6. Electricity market 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-09-01

    The electricity markets in the Nordic countries have undergone major changes since the electricity market reform work was started in the early 1990s. Sweden, Norway and Finland have had a common electricity market since 1996. The work of also reforming the Danish electricity market was begun in the year 2000. The objective of the electricity market reform is to introduce increased competition, to give the consumers greater freedom of choice and also, by open and expanded trade in electricity, create the conditions for efficient pricing. The Swedish National Energy Administration is the supervisory authority as specified in the Electricity Act, and one of the tasks entrusted to it by the Government is to follow developments on the electricity market and to regularly compile and report current market information. The purpose of the 'Electricity market 2001' publication is to meet the need for generalized and readily accessible information on the conditions on the Nordic market. Iceland is not included in the description. The publication also includes summaries of information from recent years concerning electricity generation and utilization in the Nordic countries, the structure of the electricity market from the players' perspective, trade in electricity in the Nordic countries and in Northern Europe, electricity prices in the Nordic and other countries, and the impact of the electricity sector on the environment. The publication contains data on electricity generation and use during the past years, structure of the electricity market, trade in electricity in the Nordic countries and northern Europe, electricity prices in the Nordic countries and other countries as well as impact of electricity generation system on the environment.

  7. Electricity market 2001

    International Nuclear Information System (INIS)

    2001-09-01

    The electricity markets in the Nordic countries have undergone major changes since the electricity market reform work was started in the early 1990s. Sweden, Norway and Finland have had a common electricity market since 1996. The work of also reforming the Danish electricity market was begun in the year 2000. The objective of the electricity market reform is to introduce increased competition, to give the consumers greater freedom of choice and also, by open and expanded trade in electricity, create the conditions for efficient pricing. The Swedish National Energy Administration is the supervisory authority as specified in the Electricity Act, and one of the tasks entrusted to it by the Government is to follow developments on the electricity market and to regularly compile and report current market information. The purpose of the 'Electricity market 2001' publication is to meet the need for generalized and readily accessible information on the conditions on the Nordic market. Iceland is not included in the description. The publication also includes summaries of information from recent years concerning electricity generation and utilization in the Nordic countries, the structure of the electricity market from the players' perspective, trade in electricity in the Nordic countries and in Northern Europe, electricity prices in the Nordic and other countries, and the impact of the electricity sector on the environment. The publication contains data on electricity generation and use during the past years, structure of the electricity market, trade in electricity in the Nordic countries and northern Europe, electricity prices in the Nordic countries and other countries as well as impact of electricity generation system on the environment

  8. HVDC Ground Electrodes - a Source of Geophysical Data

    Science.gov (United States)

    Freire, P. F.; Pereira, S. Y.

    2015-12-01

    The HVDC electrode is a component of a High Voltage Direct Current energy transmission system, and is designed to inject into the ground continuous currents up to 3500 A. The typical HVDC ground electrode is a ring of vertical conductors, 1 km wide, buried a few tens of meters.The design of a HVDC electrode is based on extensive geological, geotechnical and geophysical surveys. Geophysical data are usually electrical (VES) and electromagnetic (TEM/MT) acquisitions, for the modeling of the shallow, near-surface and deep layers of the crust. This survey aims, first, the electrode site selection, and then, at the selected site, this data is combined into a single apparent resistivity curve, which is inverted, allowing for the determination of the layered geoelectric crust model. The injection of electrical continuous current in the electrode is then simulated, with the geoelectric crust model, for the determination of the soil surface potential profile (which is usually asymmetric for different directions, due to non-1D geoelectric models).For the commissioning of a HVDC electrode, field measurements are done, such as electrode grounding resistance, soil surface potentials and metal-to-soil potentials at specific structures (buried pipelines, for instance).The geophysical data acquired during the design phase is a set of data completely independent from the electrical data acquired during the electrode commissioning phase, and both are correlated by the geoelectric model. It happens, therefore, that the geoelectric model can be calibrated based on the electrical data, with the correction of static shifts and other adjustments.This paper suggests that the commissioning of HVDC systems should be associated to a research & development program, with a university or foundation. The idea is to enjoy the opportunity of a more complete field survey, with the acquisition of a wide set of data for a better geological characterization of the area where the electrode was built.

  9. Discrete complex images in modeling antennas over, below or penetrating the ground

    International Nuclear Information System (INIS)

    Arnautovski-Toseva, Vesna; Smokvarski, Aleksandar; Popovski, Borislav; Grcev, Leonid

    2002-01-01

    In this paper discrete complex images (DCI) are used to obtain approximate, efficient and fast solution of Sommerfeld integrals that appear in the analysis of vertical electric dipole (VED) in presence of air-ground half-space. The results are used to model vertical antenna above, below or penetrating the ground using the moment method technique with triangular expansion functions. Thus, the time consuming direct numerical evaluation of the Sommerfeld integrals is completely or partially avoided. (Author)

  10. Typhoon-Induced Ground Deformation

    Science.gov (United States)

    Mouyen, M.; Canitano, A.; Chao, B. F.; Hsu, Y.-J.; Steer, P.; Longuevergne, L.; Boy, J.-P.

    2017-11-01

    Geodetic instruments now offer compelling sensitivity, allowing to investigate how solid Earth and surface processes interact. By combining surface air pressure data, nontidal sea level variations model, and rainfall data, we systematically analyze the volumetric deformation of the shallow crust at seven borehole strainmeters in Taiwan induced by 31 tropical cyclones (typhoons) that made landfall to the island from 2004 to 2013. The typhoon's signature consists in a ground dilatation due to air pressure drop, generally followed by a larger ground compression. We show that this compression phase can be mostly explained by the mass loading of rainwater that falls on the ground and concentrates in the valleys towards the strainmeter sensitivity zone. Further, our analysis shows that borehole strainmeters can help quantifying the amount of rainwater accumulating and flowing over a watershed during heavy rainfalls, which is a useful constraint for building hydrological models.

  11. Free Swimming in Ground Effect

    Science.gov (United States)

    Cochran-Carney, Jackson; Wagenhoffer, Nathan; Zeyghami, Samane; Moored, Keith

    2017-11-01

    A free-swimming potential flow analysis of unsteady ground effect is conducted for two-dimensional airfoils via a method of images. The foils undergo a pure pitching motion about their leading edge, and the positions of the body in the streamwise and cross-stream directions are determined by the equations of motion of the body. It is shown that the unconstrained swimmer is attracted to a time-averaged position that is mediated by the flow interaction with the ground. The robustness of this fluid-mediated equilibrium position is probed by varying the non-dimensional mass, initial conditions and kinematic parameters of motion. Comparisons to the foil's fixed-motion counterpart are also made to pinpoint the effect that free swimming near the ground has on wake structures and the fluid-mediated forces over time. Optimal swimming regimes for near-boundary swimming are determined by examining asymmetric motions.

  12. Compensation for incoherent ground motion

    International Nuclear Information System (INIS)

    Shigeru, Takeda; Hiroshi, Matsumoto; Masakazu, Yoshioka; Yasunori, Takeuchi; Kikuo, Kudo; Tsuneya, Tsubokawa; Mitsuaki, Nozaki; Kiyotomo, Kawagoe

    1999-01-01

    The power spectrum density and coherence function for ground motions are studied for the construction of the next generation electron-positron linear collider. It should provide a center of mass energy between 500 GeV-1 TeV with luminosity as high as 10 33 to 10 34 cm -2 sec -1 . Since the linear collider has a relatively slow repetition rate, large number of particles and small sizes of the beam should be generated and preserved in the machine to obtain the required high luminosity. One of the most critical parameters is the extremely small vertical beam size at the interaction point, thus a proper alignment system for the focusing and accelerating elements of the machine is necessary to achieve the luminosity. We describe recent observed incoherent ground motions and an alignment system to compensate the distortion by the ground motions. (authors)

  13. The automated ground network system

    Science.gov (United States)

    Smith, Miles T.; Militch, Peter N.

    1993-01-01

    The primary goal of the Automated Ground Network System (AGNS) project is to reduce Ground Network (GN) station life-cycle costs. To accomplish this goal, the AGNS project will employ an object-oriented approach to develop a new infrastructure that will permit continuous application of new technologies and methodologies to the Ground Network's class of problems. The AGNS project is a Total Quality (TQ) project. Through use of an open collaborative development environment, developers and users will have equal input into the end-to-end design and development process. This will permit direct user input and feedback and will enable rapid prototyping for requirements clarification. This paper describes the AGNS objectives, operations concept, and proposed design.

  14. 46 CFR 183.376 - Grounded distribution systems (neutral grounded).

    Science.gov (United States)

    2010-10-01

    ....376 Section 183.376 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER... propulsion, power, lighting, or distribution system having a neutral bus or conductor must have the neutral... generator to ground before the generator is connected to the bus, except the neutral of an emergency power...

  15. 46 CFR 120.376 - Grounded distribution systems (Neutral grounded).

    Science.gov (United States)

    2010-10-01

    ....376 Section 120.376 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS CARRYING MORE THAN 150 PASSENGERS OR WITH OVERNIGHT ACCOMMODATIONS FOR MORE THAN 49 PASSENGERS... distribution system having a neutral bus or conductor must have the neutral grounded. (c) The neutral or each...

  16. Electric field-decoupled electroosmotic pump for microfluidic devices.

    Science.gov (United States)

    Liu, Shaorong; Pu, Qiaosheng; Lu, Joann J

    2003-09-26

    An electric field-free electroosmotic pump has been constructed and its pumping rate has been measured under various experimental conditions. The key component of the pump is an ion-exchange membrane grounding joint that serves two major functions: (i) to maintain fluid continuity between pump channels and microfluidic conduit and (ii) to ground the solution in the microfluidic channel at the joint through an external electrode, and hence to decouple the electric field applied to the pump channels from the rest of the microfluidic system. A theoretical model has been developed to calculate the pumping rates and its validity has been demonstrated.

  17. Ground-truth measurement systems

    Science.gov (United States)

    Serafin, R.; Seliga, T. A.; Lhermitte, R. M.; Nystuen, J. A.; Cherry, S.; Bringi, V. N.; Blackmer, R.; Heymsfield, G. M.

    1981-01-01

    Ground-truth measurements of precipitation and related weather events are an essential component of any satellite system designed for monitoring rainfall from space. Such measurements are required for testing, evaluation, and operations; they provide detailed information on the actual weather events, which can then be compared with satellite observations intended to provide both quantitative and qualitative information about them. Also, very comprehensive ground-truth observations should lead to a better understanding of precipitation fields and their relationships to satellite data. This process serves two very important functions: (a) aiding in the development and interpretation of schemes of analyzing satellite data, and (b) providing a continuing method for verifying satellite measurements.

  18. The Mirror in the Ground

    DEFF Research Database (Denmark)

    Shepherd, Nick

    An important and original contribution to the study of the archive, The Mirror in the Ground approaches the discipline of archaeology in South Africa from the perspective of an interest in visualities. Author Nick Shepherd argues that it makes sense to talk about an archaeological aesthetics...... at the University of Cape Town, where he convenes a graduate programme on Public Culture and Heritage. The Mirror in the Ground is the first volume in the relaunched Series in Visual Histories, produced by the Centre for Curating the Archive (CCA) at the University of Cape Town....

  19. Investigating airborne low frequency GPR antenna-ground coupling through modelling

    CSIR Research Space (South Africa)

    Vogt, D

    2013-10-01

    Full Text Available . The plane of symmetry is a perfect electric conductor. The models are run using two rock materials: granite and dolerite, from the catalogue in Vogt (2000). These two materials cover the range of electrical properties expected for Karoo sediments... that is refracted into the ground away from the antenna travels along the surface at a greater velocity than the propagation in the ground, causing a propagation shape that has “ears” which are flatter than the typical spherical propagation in the earth...

  20. Ground ice conditions in Salluit, Northern Quebec

    Science.gov (United States)

    Allard, M.; Fortier, R.; Calmels, F.; Gagnon, O.; L'Hérault, E.

    2011-12-01

    Salluit in Northern Québec (ca. 1300 inhabitants) faces difficult ground ice conditions for its development. The village is located in a U-shaped valley, along a fjord that was deglaciated around 8000 cal BP. The post-glacial marine limit is at the current elevation of 150 m ASL. Among the mapped surficial geology units, three contain particularly ice-rich permafrost: marine clays, till and silty colluviums. A diamond drill was used to extract 10 permafrost cores down to 23 m deep. In addition, 18 shallow cores (to 5 m deep) were extracted with a portable drill. All the frozen cores were shipped to Québec city where ground ice contents were measured and cryostructures were imaged by CT-Scanning. Water contents, grain-size and pore water salinity were measured. Refraction seismic profiles were run to measure the depth to bedrock. GPR and electrical resistivity surveys helped to map ice-rich areas. Three cone penetration tests (CPT) were run in the frozen clays to depths ranging from 8 to 21 m. Maximum clay thickness is ca. 50 m deep near the shoreline. The cone penetration tests and all the cores in clays revealed large amounts of both segregated and aggradational ice (volumetric contents up to 93% over thicknesses of one meter) to depths varying between 2.5 and 4 m, below which the ice content decreases and the salinity increases (values measured up to 42 gr/L between 4.5 and 6 m deep). Chunks of organic matter buried below the actual active layer base indicate past cryoturbations under a somewhat warmer climate, most probably associated with intense frost boil action, as widely observed today. The stony till has developed large quantities of segregation ice which can be seen in larger concentrations and as thicker lenses under boulders and in matrix rich (≥ 50% sand and silt) parts of the glacial sediment. As digging for a sewage pond was undertaken in winter 2008 by blasting, the clast-influenced cryostructure of the till could be observed in cuts and in

  1. Electrical installation calculations advanced

    CERN Document Server

    Kitcher, Christopher

    2013-01-01

    All the essential calculations required for advanced electrical installation workThe Electrical Installation Calculations series has proved an invaluable reference for over forty years, for both apprentices and professional electrical installation engineers alike. The book provides a step-by-step guide to the successful application of electrical installation calculations required in day-to-day electrical engineering practiceA step-by-step guide to everyday calculations used on the job An essential aid to the City & Guilds certificates at Levels 2 and 3For apprentices and electrical installatio

  2. Electricity restructuring in Turkey

    International Nuclear Information System (INIS)

    Oezkyvrak, Oezlem

    2005-01-01

    Turkey implemented the electricity sector reform by which the Electricity Market Law no. 4628 passed in February 2001. Recently, all segments of the Turkish electricity sector are dominated by a vertically integrated, public-owned monopoly - Tuerkiye Elektrik Kurumu - the Turkish electricity institution. The Turkish electricity reform involves vertical deintegration of generation, transmission and distribution, introduction of competition into generation and retail sale, establishment of an independent regulatory authority and privatization of public generation and distribution entities. This article provides an overview of the Turkish electricity sector reform and defines some problems that may affect the reform success

  3. Electrical machines diagnosis

    CERN Document Server

    Trigeassou, Jean-Claude

    2013-01-01

    Monitoring and diagnosis of electrical machine faults is a scientific and economic issue which is motivated by objectives for reliability and serviceability in electrical drives.This book provides a survey of the techniques used to detect the faults occurring in electrical drives: electrical, thermal and mechanical faults of the electrical machine, faults of the static converter and faults of the energy storage unit.Diagnosis of faults occurring in electrical drives is an essential part of a global monitoring system used to improve reliability and serviceability. This diagnosis is perf

  4. Approaches to Electric Utility Energy Efficiency for Low Income Customers in a Changing Regulatory Environment

    Energy Technology Data Exchange (ETDEWEB)

    Brockway, N.

    2001-05-21

    As the electric industry goes through a transformation to a more market-driven model, traditional grounds for utility energy efficiency have come under fire, undermining the existing mechanisms to fund and deliver such services. The challenge, then, is to understand why the electric industry should sustain investments in helping low-income Americans use electricity efficiently, how such investments should be made, and how these policies can become part of the new electric industry structure. This report analyzes the opportunities and barriers to leveraging electric utility energy efficiency assistance to low-income customers during the transition of the electric industry to greater competition.

  5. Casebook on electric safety accidents

    International Nuclear Information System (INIS)

    1987-09-01

    This book gives concentration on electric safety accidents in domestic and abroad, which introduces general electrical safety with property of electricity, safe equipment and maintenance and protection of electric shock. It lists the cases of accident caused of electricity in domestic like accident in power substation, utilization equipment, load system and another accident by electricity like death in electric shock another by electricity like death in electric shock in new building construction, the cases caused of electricity in abroad like damage in electric shock by high voltage electric transformer, electric shock in summer and earth fault accident by fault cooling tower.

  6. General conditions for electric power supply

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    If it is uncertain whether future power bills will be paid fully, it is admissible to take an action claiming a declaration which states that the electricity rate payment boycotter has no right to non-payment nor a right to withhold payment towards the electricity supply utility, and that the electricity supply utility has the right to stop energy supply because of reduced electricity rate payments effected and/or announced, and to denounce the contract without observing any term of notice. If the electricity buyer reduces a power bill to be paid without any legal grounds, the electricity supply utility has the right to stop power supplies and to denounce the power supply contract without observing any term of notice. The freedom of thought and the freedom of opinion must not be expressed by reducing power bills to be paid. Basic rights discontinue to be effective as soon as a contract or law is broken. A weighing of protected interests is not effected if the exercise of a basic law is unlawful. (orig./HP) [de

  7. Green electricity buyer's guide

    International Nuclear Information System (INIS)

    Kelly, B.; Klein, S.; Olivastri, B.

    2002-06-01

    The electricity produced in whole or in large part from renewable energy sources like wind, small hydro electricity and solar energy, is generally referred to as green electricity. The authors designed this buyer's guide to assist customers in their understanding of green electricity, as the customers can now choose their electricity supplier. The considerations and steps involved in the purchasse of green electricity are identified, and advice is provided on ways to maximize the benefits from the purchase of green electricity. In Alberta and Ontario, customers have access to a competitive electricity market. The emphasis when developing this guide was placed firmly on the large buyers, as they can have enormous positive influence on the new market for green electricity. The first chapter of the document provides general information on green electricity. In chapter two, the authors explore the opportunity for environmental leadership. Chapter three reviews the basics of green electricity, which provides the link to chapter four dealing with the creation of a policy. Purchasing green electricity is dealt with in Chapter five, and maximizing the benefits of green electricity are examined in Chapter Six. 24 refs., 3 tabs

  8. Electricity market 2000

    Energy Technology Data Exchange (ETDEWEB)

    Korsfeldt, T.; Petsala, B.

    2000-08-01

    The electricity markets in the Nordic countries have undergone major changes since the electricity market reform work was started in the early 1990s. Sweden, Norway and Finland have a common electricity market since 1996.The work of also reforming the Danish electricity market was begun in the year 2000. The objective of the electricity market reform is to introduce increased competition,to give the consumers greater freedom of choice and also, by open and expanded trade in electricity, create the conditions for efficient pricing. The Swedish National Energy Administration is the supervisory authority as specified in the Electricity Act, and one of the tasks entrusted to it by the Government is to follow developments on the electricity market and to regularly compile and report current market information. The purpose of the present publication is to meet the need for generalized and readily accessible information on the conditions on the Nordic markets.The publication includes summaries of information from recent years concerning electricity generation and utilization in the Nordic countries, the structure of the electricity market from the players' perspective trade in electricity in the Nordic countries and in Northern Europe, electricity prices in the Nordic and other countries, and the impact of the electricity sector on the environment.

  9. Electrical transformer handbook

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, R.W.; Horne, D. (eds.)

    2005-07-01

    This handbook is a valuable user guide intended for electrical engineering and maintenance personnel, electrical contractors and electrical engineering students. It provides current information on techniques and technologies that can help extend the life of transformers. It discusses transformer testing, monitoring, design, commissioning, retrofitting and other elements involved in keeping electrical transformers in safe and efficient operation. It demonstrates how a power transformer can be put to use and common problems faced by owners. In addition to covering control techniques, testing and maintenance procedures, this handbook covers the power transformer; control electrical power transformer; electrical power transformer; electrical theory transformer; used electrical transformer; down electrical step transformer; electrical manufacturer transformer; electrical picture transformer; electrical transformer work; electrical surplus transformer; current transformer; step down transformer; voltage transformer; step up transformer; isolation transformer; low voltage transformer; toroidal transformer; high voltage transformer; and control power transformer. The handbook includes articles from leading experts on overcurrent protection of transformers; ventilated dry-type transformers; metered load factors for low-voltage, and dry-type transformers in buildings. The maintenance of both dry-type or oil-filled transformers was discussed with reference to sealing, gaskets, oils, moisture and testing. The adoption of dynamic load practices was also discussed along with the reclamation or recycling of used lube oil, transformer dielectric fluids and aged solid insulation. A buyer's guide and directory of transformer manufacturers and suppliers was also included. refs., tabs., figs.

  10. Electricity market 2000

    International Nuclear Information System (INIS)

    Korsfeldt, T.; Petsala, B.

    2000-08-01

    The electricity markets in the Nordic countries have undergone major changes since the electricity market reform work was started in the early 1990s. Sweden, Norway and Finland have a common electricity market since 1996.The work of also reforming the Danish electricity market was begun in the year 2000. The objective of the electricity market reform is to introduce increased competition,to give the consumers greater freedom of choice and also, by open and expanded trade in electricity, create the conditions for efficient pricing. The Swedish National Energy Administration is the supervisory authority as specified in the Electricity Act, and one of the tasks entrusted to it by the Government is to follow developments on the electricity market and to regularly compile and report current market information. The purpose of the present publication is to meet the need for generalized and readily accessible information on the conditions on the Nordic markets.The publication includes summaries of information from recent years concerning electricity generation and utilization in the Nordic countries, the structure of the electricity market from the players' perspective trade in electricity in the Nordic countries and in Northern Europe, electricity prices in the Nordic and other countries, and the impact of the electricity sector on the environment

  11. 14 CFR 417.109 - Ground safety.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Ground safety. 417.109 Section 417.109... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.109 Ground safety. (a) Ground safety... 417.115(c), and subpart E of this part provide launch operator ground safety requirements. ...

  12. Ship Collision and Grounding Analysis

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup

    2010-01-01

    It is the purpose of the paper to present a review of prediction and analysis tools for collision and grounding analyses and to outline a probabilistic procedure whereby these tools can be used by the maritime industry to develop performance based rules to reduce the risk associated with human, e...

  13. The Steksovo II burial ground

    Directory of Open Access Journals (Sweden)

    Martianov Vladimir N.

    2014-12-01

    Full Text Available The article is dedicated to the results of many-years’ (1990-2010 excavations on the ancient Mordovian Steksovo II burial ground site. The burial ground had functioned in the 3rd to 13th centuries AD. The investigations revealed hundreds of burials, which enabled the researchers to judge upon the wealth of material items found and the variety of burial rites of the population that had formed the burial ground. The 1st millennium AD is characterized by bi-ritualism, while inhumation is characteristic of the 11-13th-century period; horses’ burials were also discovered. The data of the burial ground make it possible to modify the concept of the stages in ancient Mordovians ethnogenesis. It is generally attributed to the Erzya Mordvins, but in early burials the combination of the Erzya and Moksha ancientries is traced. Complexes of the items of crucial importance for the chronology of the burial are discussed in the article with a representation of statistical data characterizing funeral rites and traditions.

  14. The ground stones from Sphinx

    Czech Academy of Sciences Publication Activity Database

    Řídký, Jaroslav

    2017-01-01

    Roč. 2017, č. 21 (2017), s. 39-42 ISSN 1369-5770 Grant - others:GA ČR(CZ) GA17-03207S Institutional support: RVO:67985912 Keywords : Sudan * Mesolithic * ground stones Subject RIV: AC - Archeology, Anthropology, Ethnology OBOR OECD: Archaeology

  15. Experimental and numerical study of electrical crosstalk in photonic integrated circuits

    NARCIS (Netherlands)

    Yao, W.; Gilardi, G.; Calabretta, N.; Smit, M.K.; Wale, M.J.

    2015-01-01

    This paper presents measurement results on electrical crosstalk between interconnect lines and electro-optical phaseshifters in photonic integrated circuits. The results indicate that overall crosstalk originates from radiative and substrate coupling between lines and from shared ground connections.

  16. Electric quadrupole strength in nuclei

    International Nuclear Information System (INIS)

    Kirson, M.W.

    1979-01-01

    Isoscalar electric quadrupole strength distributions in nuclei are surveyed, and it is concluded that the strength is shared, in most cases, roughly equally between low-lying transitions and the giant quadrupole state. The same is not true of the isovector case. A simple extension of the schematic model gives a remarkably successul description of the data, and emphasizes the vital importance of the coupling between high-lying and low-lying quadrupole modes. The standadrd simple representation of the giant quadrupole resonance as produced by operating on the nuclear ground state with the quadrupole transition operator is not applicable to the isoscalar case. It is suggested that giant resonances fall into broad classes of similar states, with considerable qualitative differences between the distinct classes. (author)

  17. Electric Holding Company Areas

    Data.gov (United States)

    Department of Homeland Security — Holding companies are electric power utilities that have a holding company structure. This vector polygon layer represents the area served by electric power holding...

  18. Driving with electrical power

    International Nuclear Information System (INIS)

    Ursin, M.; Hoeckel, M.

    2008-01-01

    This article takes a look at the chances offered to the electricity supply industry by the increasing use of battery-driven vehicles - and the advantages thus offered to the environment. The use of the vehicles' batteries to form a distributed electricity storage scheme is discussed. The authors comment that, although electrically-driven vehicles consume more power, the total primary energy consumption and pollutant emissions will be reduced. The actual electricity consumption of electric vehicles and the source of this power are examined. Power saved by the reduced use of electrical heating systems and boilers could, according to the authors, be used to charge the batteries of electric vehicles. The use of these batteries as a storage system to help regulate electricity supplies is discussed and the steps to be taken for the implementation of such a system are listed

  19. Electric Car Special

    Energy Technology Data Exchange (ETDEWEB)

    Zoethout, T.; Belin, H.; Verwijs, H.; Nicola, S.; De Saint Jacob, Y.; Gatermann, R.

    2009-09-15

    In six articles, two columns and two interviews a part of this issue is dedicated to electric car developments: about winners and losers in the electric car race; a unique business model to rolling out the electric car by the electric battery company Better Place and the automobile industry Renault Nissan; interview with entrepreneur Shai Agassi of the Indian company Better Place; the development of electric cars in Germany; interview with Jean-Jacques Chanaron, an economist specialising in innovation management and a firm believer in electric cars; start of mass production of electric vehicles at the Japanese Nissan automobile industry; the constraints in Sweden in developing fuel-efficient automobiles; plans for 1 million electric or hybrid cars by 2025 in the Netherlands.

  20. Fundamentals of electrical drives

    NARCIS (Netherlands)

    Veltman, A.; Pulle, D.W.J.; de Doncker, R.W.

    2016-01-01

    Comprehensive, user-friendly, color illustrated introductory text for electrical drive systems that simplifies the understanding of electrical machine principles Updated edition covers innovations in machine design, power semi-conductors, digital signal processors and simulation software Presents

  1. Electricity and Man (Rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Asimov, Isaac

    1974-01-01

    Our whole industrial civilization depends upon cheap energy streaking out in all directions and under fingertip controls—and that would be very difficult without electric current. It would take enormous ingenuity to find substitutes. If all electricity were shut off, then all electronic devices would be dead. Electric lights would darken. Aluminum would become a rare metal. All factories would have to develop power sources on the spot and would have to switch to primitive, mechanical controls. Every house and every farm would have to give up items we have come to take for granted—not only electric lights, but electric irons, electric toasters, electric water pumps, electric control of furnaces, and so on.

  2. Electric Power Transmission Lines

    Data.gov (United States)

    Department of Homeland Security — Transmission Lines are the system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power...

  3. Switzerland's electricity supply industry

    International Nuclear Information System (INIS)

    Inwyler, Ch.

    1980-01-01

    After a short description of Switzerland's electricity supply industry, the author comments on the production and consumption of electrical energy as well as on Switzerland's role within the European grid. A brief survey of electricity supply as a service is followed by a discussion of the political tools (such as e.g. the referendum, the hearing procedure etc.), which are an essential clue for understanding the position of the electricity supply industry in Switzerland. (Auth.)

  4. Electricity electron measurement

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Sung, Rak Jin

    1985-11-01

    This book deals with measurement of electricity and electron. It is divided into fourteen chapters, which depicts basic of electricity measurement, unit and standard, important electron circuit for measurement, instrument of electricity, impedance measurement, power and power amount measurement, frequency and time measurement, waveform measurement, record instrument and direct viewing instrument, super high frequency measurement, digital measurement on analog-digital convert, magnetic measurement on classification by principle of measurement, measurement of electricity application with principle sensors and systematization of measurement.

  5. Mastering one's electricity purchases

    International Nuclear Information System (INIS)

    Belon, D.

    2005-01-01

    Manager of about 50000 public lighting areas, the inter-cities energy syndicate of Loire (SIEL) has started in 2003 a procedure in order to chose his electric power supplier conformably with the new rules of public electricity purchase and with the new organization of the electricity market. This article presents this approach and its experience feedback, concretized by the European call for bids launched by SIEL for the annual purchase of about 186 GWh of electric power. (J.S.)

  6. Electricity production of Slovakia

    International Nuclear Information System (INIS)

    Czodor, T.

    2003-01-01

    Here is examined the spatial structure of electric energy production divided in hydropower plants (through-flow and re-pumping), thermal power plants as the most expensive way of electric energy production and nuclear power plants where high difficulty and long-term realisation of construction projects and spent financial resources are pointed out. Work describes present structure of electric energy production and consumption and refers to alternative electric energy sources

  7. GPS Multipath Fade Measurements to Determine L-Band Ground Reflectivity Properties

    Science.gov (United States)

    Kavak, Adnan; Xu, Guang-Han; Vogel, Wolfhard J.

    1996-01-01

    In personal satellite communications, especially when the line-of-sight is clear, ground specular reflected signals along with direct signals are received by low gain, almost omni-directional subscriber antennas. A six-channel, C/A code processing, GPS receiver with an almost omni-directional patch antenna was used to take measurements over three types of ground to characterize 1.575 GHz specular ground reflections and ground dielectric properties. Fade measurements were taken over grass, asphalt, and lake water surfaces by placing the antenna in a vertical position at a fixed height from the ground. Electrical characteristics (conductivity and dielectric constant) of these surfaces (grass, asphalt, lake water) were obtained by matching computer simulations to the experimental results.

  8. Decreasing the cost of ground grid installations under difficult environmental conditions

    International Nuclear Information System (INIS)

    Miranda, E.P.

    1992-01-01

    The purpose of a ground grid is to provide a means to carry and dissipate electrical currents into ground under normal and fault conditions. In some cases, especially in dry rock terrain, the soil resistivity can be very high, making it difficult and very expensive to install an acceptable ground grid. Usually a soil resistivity above 200 ohm-meter is considered high. This paper discusses and provides design calculations for a successful ground grid installation in a distribution substation located in one of the worst soil conditions encountered in the industry; a very rocky terrain where the resistivity is 1800 ohm-m. It is a practical application of the theories presented in ANSI/IEEE Std. 80-1986. The design application consists of bare copper combined with conventional and a new type of ground rod. The installation cost for this application was much less than the cost associated with that of a conventional installation

  9. Electric glass capturing markets

    Energy Technology Data Exchange (ETDEWEB)

    Wikman, K.; Wikstroem, T.

    1996-11-01

    Electric glass has found its place on the construction market. In public buildings, electrically heatable windows are becoming the leading option for large glass walls. Studies on detached houses, both new and renovated, show that floor heating combined with electrically heatable windowpanes is the best choice with respect to resident`s comfort. (orig.)

  10. Electric dipole moments reconsidered

    International Nuclear Information System (INIS)

    Rupertsberger, H.

    1989-01-01

    The electric dipole moments of elementary particles, atoms, molecules and their connection to the electric susceptibility are discussed for stationary states. Assuming rotational invariance it is emphasized that for such states only in the case of a parity and time reversal violating interaction the considered particles can obtain a nonvanishing expectation value for the electric dipole moment. 1 fig., 13 refs. (Author)

  11. Electric and hybrid vehicles

    Science.gov (United States)

    1979-01-01

    Report characterizes state-of-the-art electric and hybrid (combined electric and heat engine) vehicles. Performance data for representative number of these vehicles were obtained from track and dynamometer tests. User experience information was obtained from fleet operators and individual owners of electric vehicles. Data on performance and physical characteristics of large number of vehicles were obtained from manufacturers and available literature.

  12. Future Electricity Markets

    DEFF Research Database (Denmark)

    Pinson, Pierre

    2015-01-01

    The changing face of energy production in Europe necessitates a rethink in the way that electricity markets are structured. The ‘5s’ (Future Electricity Markets) project is a multi-disciplinary project that is looking to challenge the current approach to the design and operation of electricity...

  13. Schneider Electric sozdajot set

    Index Scriptorium Estoniae

    2003-01-01

    Maailma juhtiv elektriseadmete müüja Schneider Electric ühendab oma ettevõtted Balti- ja Põhjamaades uude divisjoni, mille nimeks saab Schneider Nordic Baltic. Eestis luuakse AS Schneider Electric Eesti, mis seni tegutses AS-i Lexel Electric nime all

  14. Electric Vehicle Technician

    Science.gov (United States)

    Moore, Pam

    2011-01-01

    With President Obama's goal to have one million electric vehicles (EV) on the road by 2015, the electric vehicle technician should have a promising and busy future. "The job force in the car industry is ramping up for a revitalized green car industry," according to Greencareersguide.com. An electric vehicle technician will safely troubleshoot and…

  15. Electric Current Solves Mazes

    Science.gov (United States)

    Ayrinhac, Simon

    2014-01-01

    We present in this work a demonstration of the maze-solving problem with electricity. Electric current flowing in a maze as a printed circuit produces Joule heating and the right way is instantaneously revealed with infrared thermal imaging. The basic properties of electric current can be discussed in this context, with this challenging question:…

  16. Fundamentals of electrical drives

    CERN Document Server

    Veltman, André; De Doncker, Rik W

    2007-01-01

    Provides a comprehensive introduction to various aspects of electrical drive systems. This volume provides a presentation of dynamic generic models that cover all major electrical machine types and modulation/control components of a drive as well as dynamic and steady state analysis of transformers and electrical machines.

  17. Electricity in South Africa

    International Nuclear Information System (INIS)

    Davis, Mark; Steyn, Grove

    1998-09-01

    Contains Executive Summary and Chapters on: Introductory background; The South African energy sector; The development and regulation of the South African electricity supply industry; Electricity supply and demand; Eskom: South Africa's public utility; Electricity distribution; Household electrification; Regional integration and environmental issues; Regulation and emerging policies - pointers to the future. (Author)

  18. The electricity market 2003

    International Nuclear Information System (INIS)

    2003-01-01

    The electricity markets in the Nordic countries have undergone major changes since the electricity market reform work was started in the early 1990s. We now have a common Nordic electricity market that includes all of the Nordic countries, with the exception of Iceland. The objective of the electricity market reform is to introduce increased competition, to give consumers greater freedom of choice and also, by open and increased trade in electricity, create the conditions for efficient pricing. The Swedish Energy Agency is the supervisory authority specified in the Electricity Act, and one of the tasks entrusted to it by the Government is to follow developments on the electricity market and regularly compile and report current market information. The purpose of 'The Electricity Market 2003' publication is to meet the need for generalized and easily accessible information on the conditions on the Nordic market. The publication also includes summaries of the information from recent years concerning power generation and utilization in the Nordic countries, the structure of the electricity market from the players' perspective, trade in electricity in the Nordic countries and in northern Europe, electricity prices in the Nordic and other countries, and the impact of the electricity sector on the environment

  19. Quantum electrodynamics with nonrelativistic sources. V. Electromagnetic field correlations and intermolecular interactions between molecules in either ground or excited states

    International Nuclear Information System (INIS)

    Power, E.A.; Thirunamachandran, T.

    1993-01-01

    Spatial correlations between electromagnetic fields arising from neutral sources with electric-dipole transition moments are calculated using nonrelativistic quantum electrodynamics in the multipolar formalism. Expressions for electric-electric, magnetic-magnetic, and electric-magnetic correlation functions at two points r and r' are given for a source molecule in either a ground or an excited state. In contrast to the electric-electric and magnetic-magnetic cases there are no electric-magnetic correlations for a ground-state molecule. For an excited molecule the downward transitions contribute additional terms which have modulating factors depending on (r-r')/λ. From these correlation functions electric and magnetic energy densities are found by setting r=r'. These energy densities are then used in a response formalism to calculate intermolecular energy shifts. In the case of two ground-state molecules this leads to the Casimir-Polder potential. However, for a pair of molecules, one or both excited, there are additional terms arising from downward transitions. An important feature of these energies is that they exhibit an R -2 dependence for large intermolecular separations R. This dependence is interpreted in terms of the Poynting vector, which itself can be obtained by setting r=r' in the electric-magnetic correlation function

  20. 49 CFR 195.575 - Which facilities must I electrically isolate and what inspections, tests, and safeguards are...

    Science.gov (United States)

    2010-10-01

    ... electrical transmission tower footings, ground cables, or counterpoise, or in other areas where it is... Corrosion Control § 195.575 Which facilities must I electrically isolate and what inspections, tests, and... other structures as a single unit. (b) You must install one or more insulating devices where electrical...

  1. Development and evaluation of an ultrasonic ground water seepage meter.

    Science.gov (United States)

    Paulsen, R J; Smith, C F; O'Rourke, D; Wong, T F

    2001-01-01

    Submarine ground water discharge can influence significantly the near-shore transport and flux of chemicals into the oceans. Quantification of the sources and rates of such discharge requires a ground water seepage meter that provides continuous measurements at high resolution over an extended period of time. An ultrasonic flowmeter has been adapted for such measurements in the submarine environment. Connected to a steel collection funnel, the meter houses two piezoelectric transducers mounted at opposite ends of a cylindrical flow tube. By monitoring the perturbations of fluid flow on the propagation of sound waves inside the flow tube, the ultrasonic meter can measure both forward and reverse fluid flows in real time. Laboratory and field calibrations show that the ultrasonic meter can resolve ground water discharges on the order of 0.1 microm/sec, and it is sufficiently robust for deployment in the field for several days. Data from West Neck Bay, Shelter Island, New York, elucidate the temporal and spatial heterogeneity of submarine ground water discharge and its interplay with tidal loading. A negative correlation between the discharge and tidal elevation was generally observed. A methodology was also developed whereby data for the sound velocity as a function of temperature can be used to infer the salinity and source of the submarine discharge. Independent measurements of electrical conductance were performed to validate this methodology.

  2. Bipolar cloud-to-ground lightning flash observations

    Science.gov (United States)

    Saba, Marcelo M. F.; Schumann, Carina; Warner, Tom A.; Helsdon, John H.; Schulz, Wolfgang; Orville, Richard E.

    2013-10-01

    lightning is usually defined as a lightning flash where the current waveform exhibits a polarity reversal. There are very few reported cases of cloud-to-ground (CG) bipolar flashes using only one channel in the literature. Reports on this type of bipolar flashes are not common due to the fact that in order to confirm that currents of both polarities follow the same channel to the ground, one necessarily needs video records. This study presents five clear observations of single-channel bipolar CG flashes. High-speed video and electric field measurement observations are used and analyzed. Based on the video images obtained and based on previous observations of positive CG flashes with high-speed cameras, we suggest that positive leader branches which do not participate in the initial return stroke of a positive cloud-to-ground flash later generate recoil leaders whose negative ends, upon reaching the branch point, traverse the return stroke channel path to the ground resulting in a subsequent return stroke of opposite polarity.

  3. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  4. Evaluation of stability of foundation ground during earthquake, (1)

    International Nuclear Information System (INIS)

    Nishi, Koichi; Kanatani, Mamoru; Matsui, Ietaka; Touma, Jun-ichi

    1986-01-01

    The Central Research Institute of Electric Power Industry has advanced the research on the new location technology for nuclear power stations in order to cope with the lack of sites expected in near future. The sites on rock mass are usually used for nuclear power stations, but the location on quaternary ground, particularly on gravel ground, is one of such new technology, to which attention has been paid. It has been pointed out that this location has the advantage in the earthquake response of reactor buildings and equipment, and the prospect to ensure the stability by lowering underground water level and pile penetration has been obtained, therefore, the possibility of its realization is high. At present, the research aiming at the establishment of the method of evaluating foundation ground stability is in progress, and it is expected that the quantitative evaluation means for the aseismatic stability of quaternary ground is obtained. In this paper, the analysis techniques for forecasting the amount of subsidence at the time of earthquakes occurring accompanying the generation of excessive pore water pressure and its disappearance are reported. Also the applicability of the forecasting techniques was experimentally verified. (Kako, I.)

  5. Surface Waves Propagating on Grounded Anisotropic Dielectric Slab

    Directory of Open Access Journals (Sweden)

    Zhuozhu Chen

    2018-01-01

    Full Text Available This paper investigates the characteristics of surface waves propagating on a grounded anisotropic dielectric slab. Distinct from the existing analyses that generally assume that the fields of surface wave uniformly distribute along the transverse direction of the infinitely large grounded slab, our method takes into account the field variations along the transverse direction of a finite-width slab. By solving Maxwell’s equations in closed-form, it is revealed that no pure transverse magnetic (TM or transverse electric (TE mode exists if the fields are non-uniformly distributed along the transverse direction of the grounded slab. Instead, two hybrid modes, namely quasi-TM and quasi-TE modes, are supported. In addition, the propagation characteristics of two hybrid modes supported by the grounded anisotropic slab are analyzed in terms of the slab thickness, slab width, as well as the relative permittivity tensor of the anisotropic slab. Furthermore, different methods are employed to compare the analyses, as well as to validate our derivations. The proposed method is very suitable for practical engineering applications.

  6. Field tests of electric survey using capacitive electrodes; Kyapashita denkyoku wo mochiita denki tansarei

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, I; Iseki, S; Kobayashi, T [OYO Corp., Tokyo (Japan)

    1997-10-22

    This paper describes field test results of electric survey using capacitive electrodes. When two metal plates are approached without contacting with the ground and voltage is applied between the plates, current flows in the ground. The metal plates and the ground work as a capacitor. Charges are stored between them. These metal plates having insulation with the ground are called capacitive electrodes. When ac voltage is applied between a pair of capacitors, current flows continuously in the ground without saturating the capacitors. Resistivity of the ground can be determined by measuring the level of current flowing in the ground and the level of potential. As a result of the field tests, it was found that the present method is superior to the conventional method in around ten times. However, to obtain high quality data, water spraying, reduced towing speed at the low resistivity ground such as clay and soil, and grass mowing are required. 3 refs., 5 figs., 1 tab.

  7. Electricity demand in Tunisia

    International Nuclear Information System (INIS)

    Gam, Imen; Ben Rejeb, Jaleleddine

    2012-01-01

    This paper examines the global electricity demand in Tunisia as a function of gross domestic product in constant price, the degree of urbanization, the average annual temperature, and the real electricity price per Kwh. This demand will be examined employing annual data over a period spanning almost thirty one years from 1976 to 2006. A long run relationship between the variables under consideration is determined using the Vector Autoregressive Regression. The empirical results suggest that the electricity demand in Tunisia is sensitive to its past value, any changes in gross domestic product and electricity price. The electricity price effects have a negative impact on long-run electricity consumption. However, the gross domestic product and the past value of electricity consumption have a positive effect. Moreover, the causality test reveals a unidirectional relationship between price and electricity consumption. Our empirical findings are effective to policy makers to maintain the electricity consumption in Tunisia by using the appropriate strategy. - Highlights: ► This paper examined the electricity demand in Tunisia in the long-run. ► The empirical analysis revealed that in the long-run the electricity demand is affected by changes in its past value, GDP in constant price and real electricity price. ► There is a unidirectional relationship between price and electricity consumption, that is to say, that the electricity price causes the consumption. ► Those results suggest that a pricing policy can be an effective instrument to rationalize the electricity consumption in Tunisia in the long-run.

  8. Nuclear quadrupole moment of the 99Tc ground state

    International Nuclear Information System (INIS)

    Errico, Leonardo; Darriba, German; Renteria, Mario; Tang Zhengning; Emmerich, Heike; Cottenier, Stefaan

    2008-01-01

    By combining first-principles calculations and existing nuclear magnetic resonance (NMR) experiments, we determine the quadrupole moment of the 9/2 + ground state of 99 Tc to be (-)0.14(3)b. This confirms the value of -0.129(20)b, which is currently believed to be the most reliable experimental determination, and disagrees with two earlier experimental values. We supply ab initio calculated electric-field gradients for Tc in YTc 2 and ZrTc 2 . If this calculated information would be combined with yet to be performed Tc-NMR experiments in these compounds, the error bar on the 99 Tc ground state quadrupole moment could be further reduced

  9. Flame spread over inclined electrical wires with AC electric fields

    KAUST Repository

    Lim, Seung J.

    2017-07-21

    Flame spread over polyethylene-insulated electrical wires was studied experimentally with applied alternating current (AC) by varying the inclination angle (θ), applied voltage (VAC), and frequency (fAC). For the baseline case with no electric field applied, the flame spread rate and the flame width of downwardly spreading flames (DSFs) decreased from the horizontal case for −20° ≤ θ < 0° and maintained near constant values for −90° ≤ θ < −20°, while the flame spread rate increased appreciably as the inclination angle of upwardly spreading flames (USFs) increased. When an AC electric field was applied, the behavior of flame spread rate in DSFs (USFs) could be classified into two (three) sub-regimes characterized by various functional dependences on VAC, fAC, and θ. In nearly all cases of DSFs, a globular molten polyethylene formed ahead of the spreading flame edge, occasionally dripping onto the ground. In these cases, an effective flame spread rate was defined to represent the burning rate by measuring the mass loss due to dripping. This effective spread rate was independent of AC frequency, while it decreased linearly with voltage and was independent of the inclination angle. In DSFs, when excessively high voltage and frequency were applied, the dripping led to flame extinction during propagation and the extinction frequency correlated well with applied voltage. In USFs, when high voltage and frequency were applied, multiple globular molten PEs formed at several locations, leading to ejections of multiple small flame segments from the main flame, thereby reducing the flame spread rate, which could be attributed to the electrospray phenomenon.

  10. Electricity sequence control

    International Nuclear Information System (INIS)

    Shin, Heung Ryeol

    2010-03-01

    The contents of the book are introduction of control system, like classification and control signal, introduction of electricity power switch, such as push-button and detection switch sensor for induction type and capacitance type machinery for control, solenoid valve, expression of sequence and type of electricity circuit about using diagram, time chart, marking and term, logic circuit like Yes, No, and, or and equivalence logic, basic electricity circuit, electricity sequence control, added condition, special program control about choice and jump of program, motor control, extra circuit on repeat circuit, pause circuit in a conveyer, safety regulations and rule about classification of electricity disaster and protective device for insulation.

  11. Electrical installation calculations basic

    CERN Document Server

    Kitcher, Christopher

    2013-01-01

    All the essential calculations required for basic electrical installation workThe Electrical Installation Calculations series has proved an invaluable reference for over forty years, for both apprentices and professional electrical installation engineers alike. The book provides a step-by-step guide to the successful application of electrical installation calculations required in day-to-day electrical engineering practice. A step-by-step guide to everyday calculations used on the job An essential aid to the City & Guilds certificates at Levels 2 and 3Fo

  12. Managing electrical safety

    CERN Document Server

    Wiggins, James H, Jr

    2001-01-01

    Managing Electrical Safety provides an overview of electric basics, hazards, and established standards that enables you to understand the hazards you are likely to encounter in your workplace. Focusing on typical industrial environments-which utilize voltages much higher than household or office circuits-the author identifies the eight key components of an electrical safety program and examines each using a model safety management process. You'll learn how to identify electrical hazards, how to prescribe necessary electrical Personal Protective Equipment, how to ensure that equipment is de-ene

  13. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  14. Pragmatic electrical engineering fundamentals

    CERN Document Server

    Eccles, William

    2011-01-01

    Pragmatic Electrical Engineering: Fundamentals introduces the fundamentals of the energy-delivery part of electrical systems. It begins with a study of basic electrical circuits and then focuses on electrical power. Three-phase power systems, transformers, induction motors, and magnetics are the major topics.All of the material in the text is illustrated with completely-worked examples to guide the student to a better understanding of the topics. This short lecture book will be of use at any level of engineering, not just electrical. Its goal is to provide the practicing engineer with a practi

  15. Electric Vehicle Interaction at the Electrical Circuit Level

    Science.gov (United States)

    2018-01-01

    The objective of the Electric Vehicle Interaction at the Electrical Circuit Level project was to investigate electric vehicle (EV) charging as a means of mitigating transient over-voltages (TOVs) on the circuit level electric utility distribution gri...

  16. Impacts of climate change on electricity network business

    International Nuclear Information System (INIS)

    Martikainen, A.

    2006-04-01

    Climate has a significant impact on the electricity network business. The electricity network is under the weather pressure all the time and it is planned and constructed to withstand normal climatic stresses. The electricity network that has been planned and constructed now, is expected to be in operation next 40 years. If climatic stresses change in this period, it can cause significant impacts on electricity network business. If the impacts of climate change are figured out in advance, it is possible to mitigate negative points of climate change and exploit the positive points. In this paper the impact of climate change on electricity network business is presented. The results are based on RCAO climate model scenarios. The climate predictions were composed to the period 2016. 2045. The period 1960.1990 was used as a control period. The climate predictions were composed for precipitation, temperature, hoarfrost, thunder, ground frost and wind. The impacts of the change of the climate variables on electricity network business were estimated from technical and economical points of view. The estimation was based on the change predictions of the climate variables. It is expected that climate change will cause more damages than benefits on the electricity network business. The increase of the number of network faults will be the most significant and demanding disadvantage caused by climate change. If networks are not improved to be more resistant for faults, then thunder, heavy snow and wind cause more damages especially to overhead lines in medium voltage network. Increasing precipitation and decreasing amount of ground frost weaken the strength of soil. The construction work will be more difficult with the present vehicles because wet and unfrozen ground can not carry heavy vehicles. As a consequence of increasing temperature, the demand of heating energy will decrease and the demand of cooling energy will increase. This is significant for the electricity

  17. In situ study of the effect of ground source heat pump on shallow ground-water quality in the late Pleistocene terrace area of Tokyo, Japan

    Science.gov (United States)

    Takemura, T.; Uemura, K.; Akiba, Y.; Ota, M.

    2015-12-01

    The implementation of ground source heat pump (GSHP) systems has rapidly increased around the world, since they reduce carbon dioxide emissions and save electric energy. The GSHP system transfer heat into the geosphere zone when air conditioners are used to cool rooms or buildings. However, the effects of temperature increase on the quality of underground water has yet to be fully investigated. In order to reduce the risks of ground-water pollution by the installed GSHPs, it is important to evaluate the effect of temperature change on the ground-water quality. In this study, we installed a closed loop GSHP system on a heat exchange well along with a monitoring well drilled to measure ground-water quality and temperature. The monitoring well was drilled at 0.1cm away from the heat exchange well. We observed that changes of temperature in the heat exchange well affected the water quality, especially turbidity, in gravelly layer.

  18. Grounded theory in music therapy research.

    Science.gov (United States)

    O'Callaghan, Clare

    2012-01-01

    Grounded theory is one of the most common methodologies used in constructivist (qualitative) music therapy research. Researchers use the term "grounded theory" when denoting varying research designs and theoretical outcomes. This may be challenging for novice researchers when considering whether grounded theory is appropriate for their research phenomena. This paper examines grounded theory within music therapy research. Grounded theory is briefly described, including some of its "contested" ideas. A literature search was conducted using the descriptor "music therapy and grounded theory" in Pubmed, CINAHL PsychlNFO, SCOPUS, ERIC (CSA), Web of Science databases, and a music therapy monograph series. A descriptive analysis was performed on the uncovered studies to examine researched phenomena, grounded theory methods used, and how findings were presented, Thirty music therapy research projects were found in refereed journals and monographs from 1993 to "in press." The Strauss and Corbin approach to grounded theory dominates the field. Descriptors to signify grounded theory components in the studies greatly varied. Researchers have used partial or complete grounded theory methods to examine clients', family members', staff, music therapy "overhearers," music therapists', and students' experiences, as well as music therapy creative products and professional views, issues, and literature. Seven grounded theories were offered. It is suggested that grounded theory researchers clarify what and who inspired their design, why partial grounded theory methods were used (when relevant), and their ontology. By elucidating assumptions underpinning the data collection, analysis, and findings' contribution, researchers will continue to improve music therapy research using grounded theory methods.

  19. Electric power production contra electricity savings

    International Nuclear Information System (INIS)

    Schleisner, L.; Grohnheit, P.E.; Soerensen, H.

    1991-01-01

    The expansion of electricity-producing plants has, in Denmark until now, taken place in accordance with the demand for electricity. Recently, it has been suggested that the cost of the further development of such systems is greater than the cost of instigating and carrying out energy conservation efforts. The aim of the project was to evaluate the consequences for power producing plants of a reduction of the electricity consumption of end-users. A method for the analysis of the costs involved in the system and operation of power plants contra the costs that are involved in saving electricity is presented. In developing a model of this kind, consideration is given to the interplay of the individual saving project and the existing or future electricity supply. Thus it can be evaluated to what extent it would be advisable to substitute investments in the development of the capacity of the power plants with investments in the reduction of electricity consumption by the end users. This model is described in considerable detail. It will be tested in representative situations and locations throughout the Nordic countries. (AB) 17 refs

  20. Electric power annual, 1990

    International Nuclear Information System (INIS)

    1992-01-01

    The Electric Power Annual presents a summary of electric utility statistics at the national, regional and State levels. The objective of the publication is to provide industry decisionmakers, government policy-makers, analysts and the general public with historical data that may be used in understanding US electricity markets. ''The Industry at a Glance'' section presents a profile of the electric power industry ownership and performance; a review of key statistics for the year; and projections for various aspects of the electric power industry through 2010. Subsequent sections present data on generating capability, including proposed capability additions; net generation; fossil-fuel statistics; electricity sales, revenue, and average revenue per kilowatthour sold; financial statistics; environmental statistics; and electric power transactions. In addition, appendices provide supplemental data on major disturbances and unusual occurrences. Each section contains related text and tables and refers the reader to the appropriate publication that contains more detailed data on the subject matter

  1. Electricity in Europe

    International Nuclear Information System (INIS)

    Holmes, A.

    1985-01-01

    European electricity consumption and demand is summarized in Chapter 1. The relationship between government and electricity producers is touched on. Five further chapters examine aspects of electricity in Europe. Chapter 2 discusses the electricity trade (import and export of electricity). The next looks at the current status of nuclear power in individual European countries. The environmental impact of generating electricity (eg acid rain, radioactive waste disposal) is assessed next and then the price of electricity in Europe is reviewed (with comparisons between the countries). Profiles of the situation in each country are presented in the last chapter. There are 72 tables presenting the facts and figures on which the text is based. (U.K.)

  2. The Electric Vehicle Development

    DEFF Research Database (Denmark)

    Wang, Jingyu; Liu, Yingqi; Kokko, Ari

    2014-01-01

    In order to respond to the energy crisis and environment problem, countries carry out their research and promotion about electric vehicles. As the ten cities one thousand new energy buses started in 2009, the new energy vehicles have been greatly developed in China, while the development...... in three aspects-city environment, government and stakeholders. Then the paper discusses the promotion ways and role of government and consumer. Finally, the paper offers some suggestions to promote electric vehicles in China: focusing on feasibility and adaptability of electric vehicles, playing...... of electric vehicles is not that good. This paper selects four cities-Los Angeles, Kanagawa, Hamburg, Amsterdam-that promote electric vehicles successfully and deeply analyzes the development of electric vehicles in these four cities and analyzes the factors that affect the development of electric vehicles...

  3. Pervasive Electricity Distribution System

    Directory of Open Access Journals (Sweden)

    Muhammad Usman Tahir

    2017-06-01

    Full Text Available Now a days a country cannot become economically strong until and unless it has enough electrical power to fulfil industrial and domestic needs. Electrical power being the pillar of any country’s economy, needs to be used in an efficient way. The same step is taken here by proposing a new system for energy distribution from substation to consumer houses, also it monitors the consumer consumption and record data. Unlike traditional manual Electrical systems, pervasive electricity distribution system (PEDS introduces a fresh perspective to monitor the feeder line status at distribution and consumer level. In this system an effort is taken to address the issues of electricity theft, manual billing, online monitoring of electrical distribution system and automatic control of electrical distribution points. The project is designed using microcontroller and different sensors, its GUI is designed in Labview software.

  4. Adaptive ground implemented phase array

    Science.gov (United States)

    Spearing, R. E.

    1973-01-01

    The simulation of an adaptive ground implemented phased array of five antenna elements is reported for a very high frequency system design that is tolerant to the radio frequency interference environment encountered by a tracking data relay satellite. Signals originating from satellites are received by the VHF ring array and both horizontal and vertical polarizations from each of the five elements are multiplexed and transmitted down to ground station. A panel on the transmitting end of the simulation chamber contains up to 10 S-band RFI sources along with the desired signal to simulate the dynamic relationship between user and TDRS. The 10 input channels are summed, and desired and interference signals are separated and corrected until the resultant sum signal-to-interference ratio is maximized. Testing performed with this simulation equipment demonstrates good correlation between predicted and actual results.

  5. "Naturalist Inquiry" and Grounded Theory

    Directory of Open Access Journals (Sweden)

    Barney G. Glaser

    2004-01-01

    Full Text Available The world of Qualitative Data Analysis (QDA methodology became quite taken with LINCOLN and GUBA's book "Naturalist Inquiry" (1985. I have no issue with it with respect to its application to QDA; it helped clarify and advance so many QDA issues. However, its application to Grounded Theory (GT has been a major block on GT, as originated, by its cooptation and corruption hence remodeling of GT by default. LINCOLN and GUBA have simply assumed GT is just another QDA method, which it is not. In "The Grounded Theory Perspective II" (GLASER 2002a, Chapter 9 on credibility, I have discussed "Naturalist In­quiry" (NI thought regarding how LINCOLN and GUBA's notion of "trustworthy" data (or worrisome data orientation and how their view of constant comparison can and has remodeled and eroded GT. In this paper I will consider other aspects of NI that remodel GT. URN: urn:nbn:de:0114-fqs040170

  6. Researches in increase of efficiency of electrokinetic process of ground cleaning from radionuclides

    International Nuclear Information System (INIS)

    Prozorov, L.B.; Shcheglov, M.Y.; Nikolaevsky, V.B.; Tkachenko, A.V.

    2003-01-01

    Potentially perspective method of decontamination of ground is electrokinetic method, which basic advantage consists in an opportunity of its application for clearing ground with low filtering by ability directly on a place of local contaminated (in situ). Thus moving the large volumes of the contaminated ground is excluded. Base of this method is the processes of electromigration and electro-osmotic, proceeding in a contaminated ground lay at imposing an electrical field of a constant current. Electrokinetic method of cleaning of ground from radionuclides provides their transfer in water-soluble, mobile form, carry as positive or negative ions under influence of an electrical field into electrode chambers with their subsequent recycling.Electrokinetic method in practice can be realized as follows: in the contaminated ground establish special electrode devices, fill their electrolyte and connect to a source of a constant current. Formed in the anode device as a result of electrochemical decomposition of water the ions of hydrogen under action of an electrical field move to the cathode, thus cooperate with a ground and superside cations of radioactive elements. Desorbed cations of contaminate act in catholyte, which periodically or continuously is exposed to clearing, for example, on sorption column. Last years the experts MosNPO Radon carry out complex researches directed on development of electrokinetic technology of cleaning ground from radionuclides and heavy metals. To the present time laboratory and bench tests of electrokinetic method are carried out. The basic attention at study of process of cleaning was given to objects contaminated Cs-137, most difficult recovery an element, which is strongly fixed by clay minerals and can enter into crystal structure. (authors)

  7. Block ground interaction of rockfalls

    Science.gov (United States)

    Volkwein, Axel; Gerber, Werner; Kummer, Peter

    2016-04-01

    During a rockfall the interaction of the falling block with the ground is one of the most important factors that define the evolution of a rockfall trajectory. It steers the rebound, the rotational movement, possibly brake effects, friction losses and damping effects. Therefore, if most reliable rockfall /trajectory simulation software is sought a good understanding of the block ground interaction is necessary. Today's rockfall codes enable the simulation of a fully 3D modelled block within a full 3D surface . However, the details during the contact, i.e. the contact duration, the penetration depth or the dimension of the marks in the ground are usually not part of the simulation. Recent field tests with rocks between 20 and 80 kg have been conducted on a grassy slope in 2014 [1]. A special rockfall sensor [2] within the blocks measured the rotational velocity and the acting accelerations during the tests. External video records and a so-called LocalPositioningSystem deliver information on the travel velocity. With these data not only the flight phases of the trajectories but also the contacts with the ground can be analysed. During the single jumps of a block the flight time, jump length, the velocity, and the rotation are known. During the single impacts their duration and the acting accelerations are visible. Further, the changes of rotational and translational velocity influence the next jump of the block. The change of the rotational velocity over the whole trajectory nicely visualizes the different phases of a rockfall regarding general acceleration and deceleration in respect to the inclination and the topography of the field. References: [1] Volkwein A, Krummenacher B, Gerber W, Lardon J, Gees F, Brügger L, Ott T (2015) Repeated controlled rockfall trajectory testing. [Abstract] Geophys. Res. Abstr. 17: EGU2015-9779. [2] Volkwein A, Klette J (2014) Semi-Automatic Determination of Rockfall Trajectories. Sensors 14: 18187-18210.

  8. Ground Optical Lightning Detector (GOLD)

    Science.gov (United States)

    Jackson, John, Jr.; Simmons, David

    A photometer developed to characterize lightning from the ground is discussed. The detector and the electronic signal processing and data storage systems are presented along with field data measured by the system. The discussion will include improvements that will be incorporated to enhance the measurement of lightning and the data storage capability to record for many days without human involvement. Finally, the calibration of the GOLD system is presented.

  9. Radon determination in ground water

    Energy Technology Data Exchange (ETDEWEB)

    Segovia A, N.; Bulbulian G, S

    1991-08-15

    Studies on natural radioactivity in ground water were started in Mexico in San Luis Potosi state followed by samplings from deep wells and springs in the states of Mexico and Michoacan. The samples were analyzed for solubilized and {sup 226} Ra- supported {sup 222} Rn. Some of them were also studied for {sup 234} U/ {sup 238} U activity ratio. In this paper we discuss the activities obtained and their relationship with the geologic characteristics of the studied zones. (Author)

  10. Radon determination in ground water

    International Nuclear Information System (INIS)

    Segovia A, N.; Bulbulian G, S.

    1991-08-01

    Studies on natural radioactivity in ground water were started in Mexico in San Luis Potosi state followed by samplings from deep wells and springs in the states of Mexico and Michoacan. The samples were analyzed for solubilized and 226 Ra- supported 222 Rn. Some of them were also studied for 234 U/ 238 U activity ratio. In this paper we discuss the activities obtained and their relationship with the geologic characteristics of the studied zones. (Author)

  11. Ground calibration of DREAMS-H relative humidity device

    Science.gov (United States)

    Komu, M.; Genzer, M.; Nikkanen, T.; Schmidt, W.; Haukka, H.; Kemppinen, O.; Harri, A.-M.

    2014-04-01

    DREAMS (Dust Characterization, Risk Assessment and Environmental Analyzer on the Martian Surface) instrument suite is to be launched as part of ESA ExoMars 2016/Entry, Descent and Landing Demonstration Module (EDM). DREAMS consists of an environmental package for monitoring temperature, pressure, relative humidity, winds and dust opacity, as well as atmospheric electricity of Martian atmosphere. DREAMS instruments and scientific goals are described in [1]. Here we describe ground calibration of the relative humidity device, DREAMS-H, provided to DREAMS payload by Finnish Meteorological Institute and based on proprietary technology of Vaisala, Inc. Same kind of device is part of REMS instrument package onboard MSL Curiosity Rover [2][3].

  12. Ground-based transmission line conductor motion sensor

    International Nuclear Information System (INIS)

    Jacobs, M.L.; Milano, U.

    1988-01-01

    A ground-based-conductor motion-sensing apparatus is provided for remotely sensing movement of electric-power transmission lines, particularly as would occur during the wind-induced condition known as galloping. The apparatus is comprised of a motion sensor and signal-generating means which are placed underneath a transmission line and will sense changes in the electric field around the line due to excessive line motion. The detector then signals a remote station when a conditioning of galloping is sensed. The apparatus of the present invention is advantageous over the line-mounted sensors of the prior art in that it is easier and less hazardous to install. The system can also be modified so that a signal will only be given when particular conditions, such as specific temperature range, large-amplitude line motion, or excessive duration of the line motion, are occurring

  13. FAB - Underwater and underground electric connection between France and Great Britain via Aurigny. File of presentation of the project and of its investigation area. Project synthesis. Impact study constituting an incidence document under the Law on Water. Ground brochure + Sea brochure. Non technical summary. Deliberated opinion of the Environmental Authority on the underwater and underground electrical interconnection between France and Great-Britain via Aurigny (FAB)

    International Nuclear Information System (INIS)

    2014-11-01

    This document gathers several reports. The first one indicates the actors involved in the project of electrical interconnection between France and Great-Britain via Aurigny, presents various technical aspects and works of this project, and proposes a definition and a description of the concerned area. The second report proposes a synthetic presentation of the project: agreement process, project interest, project definition and equipment locations, project technical components and aspects, onshore and offshore environmental aspects, project status and planning. The third report analyses the various onshore aspects of the interconnection project: project description, initial situation of the environment, analysis of the project effects on the environment and on health, analysis of cumulated effects with other known projects, sketches of examined substitution solutions and reasons for the selection of the project, elements of analysis of compliance with land uses and various planning documents, measures aimed at avoiding, reducing or compensating project effects, methods to assess initial status and effects, faced difficulties. The fourth report addresses the same issues as the previous one but for offshore aspects. The fifth report is a non technical summarised presentation of the project which presents the French side, describes the elaboration approach, the offshore and onshore legs of the project, an assessment of impacts on Natura 2000 sites. It notably contains several detailed geographical and geological maps to illustrate and to highlight the various environmental, geological, economic, social, urban or landscape impacts. The last document is the detailed opinion of the Environmental Authority on this project. It addresses the context, the project principle, implementation and cost, environmental stakes and challenges, and impacts

  14. Performance degradation of integrated optical modulators due to electrical crosstalk

    NARCIS (Netherlands)

    Yao, W.; Gilardi, G.; Smit, M.K.; Wale, M.J.

    2016-01-01

    In this paper, we investigate electrical crosstalk in integrated Mach-Zehnder modulator arrays based on n-doped InP substrate and show that it can be the cause for transmitter performance degradations. In particular, a common ground return path between adjacent modulators can cause high coupling

  15. Electrically and Thermally Insulated Joint for Liquid Nitrogen Transfer

    DEFF Research Database (Denmark)

    Rasmussen, Carsten; Jensen, Kim Høj; Holbøll, Joachim T.

    1999-01-01

    A prototype of a superconducting cable is currently under construction. The cable conductor is cooled by liquid nitrogen in order to obtain superconductivity. The peripheral cooling circuit is kept at ground potential. This requires a joint which insulates both electrically and thermally...

  16. Guidelines for gloveboxes. Section 5.14: Electrical

    International Nuclear Information System (INIS)

    Tollner, R.L.

    1995-07-01

    This is the electric portion of the design guidelines for gloveboxes developed by the American Glovebox Society. The topics include applicable codes/industry standards, penetrations/feedthroughs, wireways, junction boxes, receptacles, derating factors, conductors, conductor insulation and grounding. References for the guidelines are provided

  17. Ground state properties of exotic nuclei in deformed medium mass region

    International Nuclear Information System (INIS)

    Manju; Chatterjee, R.; Singh, Jagjit; Shubhchintak

    2017-01-01

    The dipole moment, size of the nucleus and other ground state properties of deformed nuclei 37 Mg and 31 Ne are presented. Furthermore with this deformed wave function the electric dipole strength distribution for deformed nuclei 37 Mg and 31 Ne is calculated. This will allow us to investigate the two dimensional scaling phenomenon with two parameters: quadrupole deformation and separation energy

  18. Demand for electrical energy

    International Nuclear Information System (INIS)

    Bergougnoux, J.; Fouquet, D.

    1983-01-01

    The different utilizations of electric energy are reviewed in the residential and tertiary sectors, in the industry. The competitive position of electricity in regard to other fuels has been strengthned by the sudden rise in the price of oil in 1973-1974 and 1979-1980. The evolution of electricity prices depended on the steps taken to adjust the electricity generation system. The substitution of electricity applications for hydro-carbons is an essential point of energy policy. The adjustment at all times, at least cost and most reliability, of the supply of electricity to the demand for it is a major problem in the design and operation of electric systems. National demand for power at a given moment is extremely diversified. Electricity consumption presents daily and seasonal variations, and variations according to the different sectors. Forecasting power requirements is for any decision on operation or investment relating to an electrical system. Load management is desirable (prices according to the customers, optional tariffs for ''peak-day withdrawal''). To conclude, prospects for increased electricity consumption are discussed [fr

  19. Transient Analysis of Dispersive Power-Ground Plate Pairs With Arbitrarily Shaped Antipads by the DGTD Method With Wave Port Excitation

    KAUST Repository

    Li, Ping; Jiang, Li Jun; Bagci, Hakan

    2016-01-01

    A discontinuous Galerkin time-domain (DGTD) method analyzing signal/power integrity on multilayered power-ground parallel plate pairs is proposed. The excitation is realized by introducing wave ports on the antipads where electric/magnetic current

  20. Cooling of Electric Motors Used for Propulsion on SCEPTOR

    Science.gov (United States)

    Christie, Robert J.; Dubois, Arthur; Derlaga, Joseph M.

    2017-01-01

    NASA is developing a suite of hybrid-electric propulsion technologies for aircraft. These technologies have the benefit of lower emissions, diminished noise, increased efficiency, and reduced fuel burn. These will provide lower operating costs for aircraft operators. Replacing internal combustion engines with distributed electric propulsion is a keystone of this technology suite, but presents many new problems to aircraft system designers. One of the problems is how to cool these electric motors without adding significant aerodynamic drag, cooling system weight or fan power. This paper discusses the options evaluated for cooling the motors on SCEPTOR (Scalable Convergent Electric Propulsion Technology and Operations Research): a project that will demonstrate Distributed Electric Propulsion technology in flight. Options for external and internal cooling, inlet and exhaust locations, ducting and adjustable cowling, and axial and centrifugal fans were evaluated. The final design was based on a trade between effectiveness, simplicity, robustness, mass and performance over a range of ground and flight operation environments.

  1. An interpretative review of the electricity markets. A proposal

    International Nuclear Information System (INIS)

    Martini, A.; Pellegrini, L.; Gallanti, M.

    2001-01-01

    The electricity reform entails the passing from a monopolistic model based on costs to a competitive one grounded on market prices. The structural choices of the model must comply with technical constraints imposed by the electric system and have to be efficiency-driven. So far, more than a dozen of countries has completed the electricity industry restructuring process, with almost different solutions both in the architectural and the operational characteristics; this variety is even more emphasized whether developing and ready-to-start markets are considered. Starting from these premises and considering the forthcoming choices to be accomplished in order to put in competition in the Italian electric industry, as stated by the Decree n. 79 of March, 16, 1999 in reception of the European Directive n. 92/96, the paper presents a framework of the market architectures, as well as an electric auction-based market taxonomy [it

  2. Ground states of quantum spin systems

    International Nuclear Information System (INIS)

    Bratteli, Ola; Kishimoto, Akitaka; Robinson, D.W.

    1978-07-01

    The authors prove that ground states of quantum spin systems are characterized by a principle of minimum local energy and that translationally invariant ground states are characterized by the principle of minimum energy per unit volume

  3. Bidirectional DC-DC converter fed drive for electric vehicle system ...

    African Journals Online (AJOL)

    Batteries are the primary energy-storage devices in ground vehicles. Now days battery fed electric drives are commonly being used for electric vehicles applications, due to various advantages, such as: nearly zero emission, guaranteed load leveling, good transient operation and energy recovery during braking operation.

  4. Essays on electricity markets

    Energy Technology Data Exchange (ETDEWEB)

    Rud, Linda

    2009-07-01

    The report covers several topics of electricity markets: The first essay, 'Selected Topics on Early Electricity Market Design in Norway' studies market design issues in establishing the market-based Norwegian electricity market. Essays 2-4 focus on issues of network congestion: 'Capacity Charges: A Price Adjustment Process for Managing Congestion in Electricity Transmission Networks' presents the capacity charge approach for managing transmission constraints in electricity networks. 'Understanding the Stochastics of Nodal Prices: Price Processes in a Constrained Network' seeks a further understanding of stochastic nodal prices processes. 'Investment Evaluation in a Constrained Electricity Network with Stochastic Nodal Price Processes' studies how the interaction of the competitive market and the capacitated network affects the evaluation of investments under uncertainty, and points out potential pitfalls of evaluation. In the last essay, 'A Newsboy Model Perspective on the Power Market: The Case of a Wind Power Producer' we discuss aspects of optimal bidding for a wind power producer. (Author)

  5. Electrical system architecture

    Science.gov (United States)

    Algrain, Marcelo C [Peoria, IL; Johnson, Kris W [Washington, IL; Akasam, Sivaprasad [Peoria, IL; Hoff, Brian D [East Peoria, IL

    2008-07-15

    An electrical system for a vehicle includes a first power source generating a first voltage level, the first power source being in electrical communication with a first bus. A second power source generates a second voltage level greater than the first voltage level, the second power source being in electrical communication with a second bus. A starter generator may be configured to provide power to at least one of the first bus and the second bus, and at least one additional power source may be configured to provide power to at least one of the first bus and the second bus. The electrical system also includes at least one power consumer in electrical communication with the first bus and at least one power consumer in electrical communication with the second bus.

  6. Electric power monthly

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    The Energy Information Administration (EIA) prepares the Electric Power Monthly (EPM) for a wide audience including Congress, Federal and State agencies, the electric utility industry, and the general public. This publication provides monthly statistics for net generation, fossil fuel consumption and stocks, quantity and quality of fossil fuels, cost of fossil fuels, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fossil fuels are also displayed for the North American Electric Reliability Council (NERC) regions. The EIA publishes statistics in the EPM on net generation by energy source, consumption, stocks, quantity, quality, and cost of fossil fuels; and capability of new generating units by company and plant. The purpose of this publication is to provide energy decisionmakers with accurate and timely information that may be used in forming various perspectives on electric issues that lie ahead.

  7. Impacts of climate change on electricity network business

    International Nuclear Information System (INIS)

    Auvinen, O.; Martikainen, A.

    2006-01-01

    In this project the impact of climate change on electricity network business was study. The results are based on RCAO climate model scenarios. The climate predictions were composed to the period 2016- 2045. The period 1960-1990 was used as a control period. The climate predictions were composed for precipitation, temperature, hoarfrost, thunder, ground frost and wind. Impacts of the change of the climate variables on electricity network business were estimated from technical and economical points of view. It is expected that climate change will cause more damages than benefits on the electricity network business. The increase of the number of network faults will be the most significant and demanding disadvantage caused by climate change in distribution network. If networks are not improved to be more resistant for faults, then thunder, heavy snow and wind cause more damages especially to overhead lines in medium voltage network. Increasing precipitation and decreasing amount of ground frost weaken the strength of soil. The construction work will be more difficult with the present vehicles because wet and unfrozen ground can not carry heavy vehicles. As a consequence of increasing temperature, the demand of heating energy will decrease and the demand of cooling energy will increase. This is significant for the electricity consumption and the peak load of temperature-dependent electricity users. (orig.)

  8. Methodological proposal of grounding in commercial and industrial installations

    International Nuclear Information System (INIS)

    Rodriguez Araya, Michael Eduardo

    2013-01-01

    A methodology is elaborated for the design of methods of commercial and industrial grounding. International standards and technical documents related with the grounding in the electrical design are studied in commercial and industrial installations. The design techniques of earthing systems are investigated. The topics that were covered to develop a design proposal have been: the analysis of resistivity, soil types, calculations of step voltages, contact and voltage of mesh. A field visit is programmed in nearby of the Escuela de Ingenieria Electrica at the Universidad de Costa Rica, to realize the pertinent measurements of resistivity for the design of a hypothetical grounding mesh for a future installation. The tellurometer (GP-1 model) of the brand Amprobe Instrument was used to provide the data from ground resistivity. The equipment has used four electrodes and has implemented the Wenner method for calculations. A earthing design is realized in a company in the industrial or commercial sector of Costa Rica. The earthing designs are realized to protect equipments found at the site and are affected by conditions such as: atmospheric overloads, transients, sags, interruptions or any event that may to affect the quality of the energy. The resistivity of an ground has depended largely on the amount of moisture that has presented. A correct earthing system should cover the greater amount of the total area of the building, and to comply with the voltage of mesh necessary for the design has been optimal. The design of any earthing has depended on unique characteristics that have been indicated by the location of industry [es

  9. Ground effect aerodynamics of racing cars

    OpenAIRE

    Zhang, Xin; Toet, Willem; Zerihan, Jonathan

    2006-01-01

    We review the progress made during the last thirty years on ground effect aerodynamics associated with race cars, in particular open wheel race cars. Ground effect aerodynamics of race cars is concerned with generating downforce, principally via low pressure on the surfaces nearest to the ground. The “ground effected” parts of an open wheeled car's aerodynamics are the most aerodynamically efficient and contribute less drag than that associated with, for example, an upper rear wing. Whilst dr...

  10. The Development of Constructivist Grounded Theory

    OpenAIRE

    Jane Mills; Ann Bonner; Karen Francis

    2006-01-01

    Constructivist grounded theory is a popular method for research studies primarily in the disciplines of psychology, education, and nursing. In this article, the authors aim to locate the roots of constructivist grounded theory and then trace its development. They examine key grounded theory texts to discern their ontological and epistemological orientation. They find Strauss and Corbin's texts on grounded theory to possess a discernable thread of constructivism in their approach to inquiry. T...

  11. Control of Electric Vehicle

    OpenAIRE

    Huang, Qi; Chen, Yong; Li, Jian

    2010-01-01

    In this chapter, the modeling of electric vehicle is discussed in detail. Then, the control of electric vehicle driven by different motors is discussed. Both brushed and brushless DC (Direct Current) motors are discussed. And for AC (Alternative Current) motors, the discussion is focused on induction motor and permanent magnet synchronous motor. The design of controllers for different motor-driven electric vehicle is discussed in-depth, and the tested high-performance control strategies for d...

  12. The earth's electrical environment

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    This latest addition to the Studies in Geophysics series explores in scientific detail the phenomenon of lighting, cloud and thunderstorm electricity, and global and regional electrical processes. Consisting of 16 papers by outstanding experts in a number of fields, this volume compiles and reviews many recent advances in such research areas as meteorology, chemistry, electrical engineering, and physics and projects how new knowledge could be applied to benefit mankind

  13. Principles of electrical safety

    CERN Document Server

    Sutherland, Peter E

    2015-01-01

    Principles of Electrical Safety discusses current issues in electrical safety, which are accompanied by series' of practical applications that can be used by practicing professionals, graduate students, and researchers. .  Provides extensive introductions to important topics in electrical safety Comprehensive overview of inductance, resistance, and capacitance as applied to the human body Serves as a preparatory guide for today's practicing engineers

  14. Operational electricity transmission rates

    International Nuclear Information System (INIS)

    Roggen, M.

    1997-01-01

    In a liberalized electricity market both the consumers and the producers of electricity must pay for the use of the power transmission network. Thus, the net manager has unlimited options to realize efficiency improvements. A neutral and transparent management of the power grid is necessary to avoid disturbance of the market. KEMA Consulting translated abstract ideas and strategic advices to operational concepts in its report 'A framework for the determination of tariffs of the transport in the Dutch electricity sector'

  15. Perspectives of electricity supply

    International Nuclear Information System (INIS)

    1988-01-01

    The 7 papers read at the symposium discussed the following subjects: Effects of the CO 2 problems of fossil energy systems on the world climate; status and perspectives of the German electricity industry in terms of competitiveness; The European electricity market and the integrated power supply system; Power supply without nuclear power; Costs and rates for households and other customers; Renewable energy sources and their contribution to energy supply in the Federal Republic of Germany; Electricity utilities as service partners. (UA) [de

  16. Competition in electricity markets

    International Nuclear Information System (INIS)

    Taylor, W.

    1996-01-01

    This article examines expanded wholesale and retail competition and the effect that they are likely to have on the electric power industry. The author believes that expanded wholesale competition is good and will bring immediate benefit to all electric consumers; however, based on the experience of the natural gas industry and the electric power industry in California and other parts of the world, the author counsels caution in moving toward expanded retail competition

  17. Electrical control of superparamagnetism

    Science.gov (United States)

    Yamada, Kihiro T.; Koyama, Tomohiro; Kakizakai, Haruka; Miwa, Kazumoto; Ando, Fuyuki; Ishibashi, Mio; Kim, Kab-Jin; Moriyama, Takahiro; Ono, Shimpei; Chiba, Daichi; Ono, Teruo

    2017-01-01

    The electric field control of superparamagnetism is realized using a Cu/Ni system, in which the deposited Ni shows superparamagnetic behavior above the blocking temperature. An electric double-layer capacitor (EDLC) with the Cu/Ni electrode and a nonmagnetic counter electrode is fabricated to examine the electric field effect on magnetism in the magnetic electrode. By changing the voltage applied to the EDLC, the blocking temperature of the system is clearly modulated.

  18. Electrical and electronic principles

    CERN Document Server

    Knight, S A

    1991-01-01

    Electrical and Electronic Principles, 2, Second Edition covers the syllabus requirements of BTEC Unit U86/329, including the principles of control systems and elements of data transmission. The book first tackles series and parallel circuits, electrical networks, and capacitors and capacitance. Discussions focus on flux density, electric force, permittivity, Kirchhoff's laws, superposition theorem, arrangement of resistors, internal resistance, and powers in a circuit. The text then takes a look at capacitors in circuit, magnetism and magnetization, electromagnetic induction, and alternating v

  19. Essays on electricity theft

    Science.gov (United States)

    Steadman, Keva Ullanda

    Electricity theft is a relatively unknown crime with high economic costs. In this dissertation, I try to identify the factors that motivate persons to steal electricity. First, I use a panel dataset of 97 countries spanning the five year period 2003--2007 to estimate a model that describes the effect of the unemployment rate, GDP per capita, male population and urbanization on theft, robbery and homicide rates. The results are consistent with previous empirical work on crime and economic opportunity. The second and main contribution of this paper is to estimate the same model using distribution loss as a proxy for electricity theft. The results show that the unemployment rate, a key explanatory economic factor for crime, cannot explain variation in electricity theft, although there is some evidence, albeit weak, supporting correlation in rich countries. Therefore, policies that target the reduction of property crime through a reduction in unemployment will have no effect on electricity theft. The third contribution relates to the role that political institutions play in the incentives to steal electricity. After control for socioeconomic factors, I find that there is no relationship between political governance indicators and electricity theft. In the second and third chapters, I compare the United States, a high income, low electricity theft country with Jamaica, a middle income, high electricity theft country. The effect of unemployment on electricity theft mirrors the results found in the first chapter. In the United States, electricity theft is affected by changes in economic conditions but in Jamaica, it is not. These results suggest that the state of institutions plays a role in how social norms are determined. Poor countries will be more likely than rich countries to have weak institutions with social norms that encourage electricity theft.

  20. Electricity in France

    International Nuclear Information System (INIS)

    Audigier, Pierre

    1999-12-01

    Contains Executive Summary and Chapters on: Historical background; The Nationalisation Law of 1946 and the present electricity regulatory framework; Other regulations and policies having an impact on the French electricity system; Forces for and against Liberalisation; The legislative framework in preparation; Electricity costs and prices; The main industrial player. EdF; Key nuclear issues; EdF and the HV transmission network; The non-nationalised distributors; Other players on the generation side; Conclusions. (Author)

  1. A new energy analysis tool for ground source heat pump systems

    Energy Technology Data Exchange (ETDEWEB)

    Michopoulos, A.; Kyriakis, N. [Process Equipment Design Laboratory, Mechanical Engineering Department, Aristotle University of Thessaloniki, POB 487, 541 24 Thessaloniki (Greece)

    2009-09-15

    A new tool, suitable for energy analysis of vertical ground source heat pump systems, is presented. The tool is based on analytical equations describing the heat exchanged with the ground, developed in Matlab {sup registered} environment. The time step of the simulation can be freely chosen by the user (e.g. 1, 2 h etc.) and the calculation time required is very short. The heating and cooling loads of the building, at the afore mentioned time step, are needed as input, along with the thermophysical properties of the soil and of the ground heat exchanger, the operation characteristic curves of the system's heat pumps and the basic ground source heat exchanger dimensions. The results include the electricity consumption of the system and the heat absorbed from or rejected to the ground. The efficiency of the tool is verified through comparison with actual electricity consumption data collected from an existing large scale ground coupled heat pump installation over a three-year period. (author)

  2. Fringe effect of electrical capacitance and resistance tomography sensors

    International Nuclear Information System (INIS)

    Sun, Jiangtao; Yang, Wuqiang

    2013-01-01

    Because of the ‘soft-field’ nature, all electrical tomography sensors suffer from electric field distortion, i.e. the fringe effect. In electrical resistance tomography (ERT) sensors, small pin electrodes are commonly used. It is well known that the pin electrodes result in severe electric field distortion or the fringe effect, and the sensing region of such an ERT sensor spreads out of the pin electrode plane to a large volume. This is also true for electrical capacitance tomography (ECT) sensors, even though it is less severe because of larger electrodes and grounded end guards used. However, when the length of electrodes in an ECT sensor without guards is reduced to almost the same dimension as those in an ERT sensor, the fringe effect is equally obvious. To investigate the fringe effect of ERT and ECT sensors with and without guards, simulations were carried out with different length of electrodes and the results are compared with the corresponding 2D simulation. It is concluded that ECT and ERT sensors with longer electrodes have less fringe effect. Because grounded end guards are effective in reducing the fringe effect of ECT sensors, we propose to apply grounded guards in ERT sensors and integrate ECT and ERT sensors together. Simulation results reveal that ERT sensors with grounded guards have less fringe effect. While commonly current excitation is used with ERT sensors, we propose voltage excitation instead to apply the grounded guards. The feasibility of this approach has been verified by experiment. Finally, a common structure for reducing the fringe effect is proposed for ECT and ERT sensors for the first time to simplify the sensor structure and reduce the mutual interference in ECT/ERT dual-modality measurements. (paper)

  3. An Optimal Electric Dipole Antenna Model and Its Field Propagation

    Directory of Open Access Journals (Sweden)

    Yidong Xu

    2016-01-01

    Full Text Available An optimal electric dipole antennas model is presented and analyzed, based on the hemispherical grounding equivalent model and the superposition principle. The paper also presents a full-wave electromagnetic simulation for the electromagnetic field propagation in layered conducting medium, which is excited by the horizontal electric dipole antennas. Optimum frequency for field transmission in different depth is carried out and verified by the experimental results in comparison with previously reported simulation over a digital wireless Through-The-Earth communication system. The experimental results demonstrate that the dipole antenna grounding impedance and the output power can be efficiently reduced by using the optimal electric dipole antenna model and operating at the optimum frequency in a vertical transmission depth up to 300 m beneath the surface of the earth.

  4. Atmospheric electricity. [lightning protection criteria in spacecraft design

    Science.gov (United States)

    Daniels, G. E.

    1973-01-01

    Atmospheric electricity must be considered in the design, transportation, and operation of aerospace vehicles. The effect of the atmosphere as an insulator and conductor of high voltage electricity, at various atmospheric pressures, must also be considered. The vehicle can be protected as follows: (1) By insuring that all metallic sections are connected by electrical bonding so that the current flow from a lightning stroke is conducted over the skin without any gaps where sparking would occur or current would be carried inside; (2) by protecting buildings and other structures on the ground with a system of lightning rods and wires over the outside to carry the lightning stroke into the ground; (3) by providing a zone of protection for launch complexes; (4) by providing protection devices in critical circuits; (5) by using systems which have no single failure mode; and (6) by appropriate shielding of units sensitive to electromagnetic radiation.

  5. Electricity of machine tool

    International Nuclear Information System (INIS)

    Gijeon media editorial department

    1977-10-01

    This book is divided into three parts. The first part deals with electricity machine, which can taints from generator to motor, motor a power source of machine tool, electricity machine for machine tool such as switch in main circuit, automatic machine, a knife switch and pushing button, snap switch, protection device, timer, solenoid, and rectifier. The second part handles wiring diagram. This concludes basic electricity circuit of machine tool, electricity wiring diagram in your machine like milling machine, planer and grinding machine. The third part introduces fault diagnosis of machine, which gives the practical solution according to fault diagnosis and the diagnostic method with voltage and resistance measurement by tester.

  6. Turkish electricity reform

    Energy Technology Data Exchange (ETDEWEB)

    Bagdadioglu, Necmiddin [Department of Public Finance, Hacettepe University, 06800 Ankara (Turkey); Odyakmaz, Necmi [E.ON Holding, Armada Business Centre, 06520 Ankara (Turkey)

    2009-03-15

    Turkish electricity reform has progressed slowly due to internal resistance against privatisation, and gained momentum after Electricity Market Law of 2001, prepared in line with EU Energy Acquis and established required institutional and legal framework. Although the eligibility threshold has reached 39% market opening rate, the dominant position of public both as owner and decision-maker is still the major problem in the sector. Currently Turkey is self-sufficient in electricity, but likely to face shortages in 10 years if the growing demand is not met by either speeding the liberalisation process, or joining the South East Europe Electricity Market. (author)

  7. Swiss electricity statistics 2000

    International Nuclear Information System (INIS)

    2001-01-01

    This publication by the Association of Swiss Electricity Enterprises for the Swiss Federal Office of Energy (SFOE) provides statistical information on electricity production, trading and consumption in Switzerland in 2000. Apart from a general overview of the Swiss electricity supply that includes details on power generation, energy transfer with neighbouring countries and data on prices, average consumption and capital investment, the publication also includes graphical representations of electrical energy flows in and out of Switzerland. Tables of data give information on electricity production, import and export for the years 1950 to 2000, the data being supplied for each hydrological year and the summer and winter seasons respectively. The production of power in Switzerland is examined in detail. Details are given on the development of production capacities and the various means of production together with their respective shares of total production. Further tables and diagrams provide information on power production in various geographical regions and on the management of pumped storage hydro-electricity schemes. A further chapter deals in detail with the consumption of electricity, its growth between 1984 and 2000 and its use in various sectors. A fifth chapter examines electricity consumption, generation, import and export on single, typical days, presenting data in tables and diagrams. The next chapter examines energy transfer with foreign countries and the trading structures involved. The final two chapters cover new and future power generation capacities and the economic considerations involved in the supply of electricity

  8. Electricity supply in India

    International Nuclear Information System (INIS)

    Abbott, H.J.

    1993-09-01

    This briefing deals with the electricity supply industry in India in two parts. In the first, the structure and organization of the industry is described under sections dealing with national government involvement, energy policy, state electricity boards, regional electricity boards, state corporations, the private sector and private investment in the power sector including foreign investment. Secondly, the power supply system is described covering generation, plant load factor, non-utility generation, nuclear power, transmission and distribution, system losses and electricity consumption. (8 tables) (UK)

  9. Fire protection electrical engineering

    International Nuclear Information System (INIS)

    Oh, Jung Min

    2000-03-01

    This book concentrates of electricity with current, voltage, power, ohms law, access of resistance, electrolytic analysis and battery, static on frictional electricity and electrostatic induction, coulomb's law, Gauss's law, condenser and capacity, magmatism on magnetic field and magnetic line of force, magnetic circuit, electromagnetic force, electromotive current, basic alternating current circuit, circuit network analysis, three-phase current, non-sinusoidal alternating current, transient phenomena, semiconductor, electric measurement on measurement over resistance, power, power rate and circuit tester, automatic control on introduction, term, classification, foundation of sequence control, logic circuit and basic logic circuit and electric equipment.

  10. Electricity demand in Kazakhstan

    International Nuclear Information System (INIS)

    Atakhanova, Zauresh; Howie, Peter

    2007-01-01

    Properties of electricity demand in transition economies have not been sufficiently well researched mostly due to data limitations. However, information on the properties of electricity demand is necessary for policy makers to evaluate effects of price changes on different consumers and obtain demand forecasts for capacity planning. This study estimates Kazakhstan's aggregate demand for electricity as well as electricity demand in the industrial, service, and residential sectors using regional data. Firstly, our results show that price elasticity of demand in all sectors is low. This fact suggests that there is considerable room for price increases necessary to finance generation and distribution system upgrading. Secondly, we find that income elasticity of demand in the aggregate and all sectoral models is less than unity. Of the three sectors, electricity demand in the residential sector has the lowest income elasticity. This result indicates that policy initiatives to secure affordability of electricity consumption to lower income residential consumers may be required. Finally, our forecast shows that electricity demand may grow at either 3% or 5% per year depending on rates of economic growth and government policy regarding price increases and promotion of efficiency. We find that planned supply increases would be sufficient to cover growing demand only if real electricity prices start to increase toward long-run cost-recovery levels and policy measures are implemented to maintain the current high growth of electricity efficiency

  11. Electric power annual 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-06

    The Electric Power Annual presents a summary of electric utility statistics at national, regional and State levels. The objective of the publication is to provide industry decisionmakers, government policymakers, analysts and the general public with historical data that may be used in understanding US electricity markets. The Electric Power Annual is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. ``The US Electric Power Industry at a Glance`` section presents a profile of the electric power industry ownership and performance, and a review of key statistics for the year. Subsequent sections present data on generating capability, including proposed capability additions; net generation; fossil-fuel statistics; retail sales; revenue; financial statistics; environmental statistics; electric power transactions; demand-side management; and nonutility power producers. In addition, the appendices provide supplemental data on major disturbances and unusual occurrences in US electricity power systems. Each section contains related text and tables and refers the reader to the appropriate publication that contains more detailed data on the subject matter. Monetary values in this publication are expressed in nominal terms.

  12. Semiconductor Electrical Measurements Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Semiconductor Electrical Measurements Laboratory is a research laboratory which complements the Optical Measurements Laboratory. The laboratory provides for Hall...

  13. Electric engineering summary

    International Nuclear Information System (INIS)

    Kang, Sing Eun; Park, Seong Taek; Lim, Yong Un

    1975-03-01

    This book is made up six parts, which deals with circuit theory about sinusoidal alternating current, basic current circuit, wave power, distorted wave, two terminal network, distributed circuit, laplace transformation and transfer function, power engineering on line, failure analysis transmission of line, substation and protection device and hydroelectric power plant, electricity machine like DC machine, electric transformer, induction machine and rectifier, electromagnetic on dielectric substance current, electromagnetic, electricity application like lighting engineering, heat transfer and electricity chemistry, industry, industry math with integer, rational number, factorization, matrix and differential.

  14. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  15. Electrical installations and regulations

    CERN Document Server

    Whitfield, J F

    1966-01-01

    Electrical Installations and Regulations focuses on the regulations that apply to electrical installations and the reasons for them. Topics covered range from electrical science to alternating and direct current supplies, as well as equipment for providing protection against excess current. Cables, wiring systems, and final subcircuits are also considered, along with earthing, discharge lighting, and testing and inspection.Comprised of 12 chapters, this book begins with an overview of electrical installation work, traits of a good electrician, and the regulations governing installations. The r

  16. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  17. Electric Field Imaging

    Data.gov (United States)

    National Aeronautics and Space Administration — NDE historically has focused technology development in propagating wave phenomena with little attention to the field of electrostatics and emanating electric fields....

  18. Electrically conductive cellulose composite

    Science.gov (United States)

    Evans, Barbara R.; O'Neill, Hugh M.; Woodward, Jonathan

    2010-05-04

    An electrically conductive cellulose composite includes a cellulose matrix and an electrically conductive carbonaceous material incorporated into the cellulose matrix. The electrical conductivity of the cellulose composite is at least 10 .mu.S/cm at 25.degree. C. The composite can be made by incorporating the electrically conductive carbonaceous material into a culture medium with a cellulose-producing organism, such as Gluconoacetobacter hansenii. The composites can be used to form electrodes, such as for use in membrane electrode assemblies for fuel cells.

  19. Electrical applications 2

    CERN Document Server

    Tyler, David W

    1998-01-01

    Electrical Applications 2 covers the BTEC NII level objectives in Electrical Applications U86/330. To understand the applications, a knowledge of the underlying principles is needed and these are covered briefly in the text. Key topics discussed are: the transmission and distribution of electrical energy; safety and regulations; tariffs and power factor correction; materials and their applications in the electrical industry; transformers; DC machines; illumination; and fuse protection. Included in each chapter are worked examples which should be carefully worked through before progressing to t

  20. Electric vehicle propulsion alternatives

    Science.gov (United States)

    Secunde, R. R.; Schuh, R. M.; Beach, R. F.

    1983-01-01

    Propulsion technology development for electric vehicles is summarized. Analytical studies, technology evaluation, and the development of technology for motors, controllers, transmissions, and complete propulsion systems are included.

  1. Identification of resonant earthquake ground motion

    Indian Academy of Sciences (India)

    Resonant ground motion has been observed in earthquake records measured at several parts of the world. This class of ground motion is characterized by its energy being contained in a narrow frequency band. This paper develops measures to quantify the frequency content of the ground motion using the entropy ...

  2. 7 CFR 65.170 - Ground lamb.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Ground lamb. 65.170 Section 65.170 Agriculture... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS, PEANUTS, AND GINSENG General Provisions Definitions § 65.170 Ground lamb. Ground lamb means comminuted...

  3. 7 CFR 65.160 - Ground chicken.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Ground chicken. 65.160 Section 65.160 Agriculture... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS, PEANUTS, AND GINSENG General Provisions Definitions § 65.160 Ground chicken. Ground chicken means...

  4. Ground water pollution through air pollutants

    International Nuclear Information System (INIS)

    Cichorowski, G.; Michel, B.; Versteegen, D.; Wettmann, R.

    1989-01-01

    The aim of the investigation is to determine the significance of air pollutants for ground water quality and ground water use. The report summarizes present knowledge and assesses statements with a view to potential ground water pollution from the air. In this context pollution paths, the spreading behaviour of pollutants, and 'cross points' with burden potentials from other pollutant sources are presented. (orig.) [de

  5. 7 CFR 65.165 - Ground goat.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Ground goat. 65.165 Section 65.165 Agriculture... OF BEEF, PORK, LAMB, CHICKEN, GOAT MEAT, PERISHABLE AGRICULTURAL COMMODITIES, MACADAMIA NUTS, PECANS, PEANUTS, AND GINSENG General Provisions Definitions § 65.165 Ground goat. Ground goat means comminuted...

  6. 30 CFR 77.801 - Grounding resistors.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding resistors. 77.801 Section 77.801 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH...-Voltage Distribution § 77.801 Grounding resistors. The grounding resistor, where required, shall be of the...

  7. Stop. Write! Writing Grounded Theory

    Directory of Open Access Journals (Sweden)

    Barney G. Glaser, PhD, Hon. PhD

    2012-06-01

    Full Text Available The message in this book, the dictum in this book, is to stop and write when the Grounded Theory (GT methodology puts you in that ready position. Stop unending conceptualization, unending data coverage, and unending listening to others who would egg you on with additional data, ideas and/or requirements or simply wait too long. I will discuss these ideas in detail. My experience with PhD candidates is that for the few who write when ready, many do not and SHOULD. Simply put, many write-up, but many more should.

  8. Leaders break ground for INFINITY

    Science.gov (United States)

    2008-01-01

    Community leaders from Mississippi and Louisiana break ground for the new INFINITY at NASA Stennis Space Center facility during a Nov. 20 ceremony. Groundbreaking participants included (l to r): Gottfried Construction representative John Smith, Mississippi Highway Commissioner Wayne Brown, INFINITY board member and Apollo 13 astronaut Fred Haise, Stennis Director Gene Goldman, Studio South representative David Hardy, Leo Seal Jr. family representative Virginia Wagner, Hancock Bank President George Schloegel, Mississippi Rep. J.P. Compretta, Mississippi Band of Choctaw Indians representative Charlie Benn and Louisiana Sen. A.G. Crowe.

  9. Ground level cosmic ray observations

    Energy Technology Data Exchange (ETDEWEB)

    Stephens, S.A. [Tata Institute of Fundamental Research, Bombay (International Commission on Radiation Units and Measurements); Grimani, C.; Brunetti, M.T.; Codino, A. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); Papini, P.; Massimo Brancaccio, F.; Piccardi, S. [Florence Univ. (Italy)]|[INFN, Florence (Italy); Basini, G.; Bongiorno, F. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Golden, R.L. [New Mexico State Univ., Las Cruces, NM (United States). Particle Astrophysics Lab.; Hof, M. [Siegen Univ. (Germany). Fachbereich Physik

    1995-09-01

    Cosmic rays at ground level have been collected using the NMSU/Wizard - MASS2 instrument. The 17-hr observation run was made on September 9. 1991 in Fort Sumner, New Mexico, Usa. Fort Sumner is located at 1270 meters a.s.l., corresponding to an atmospheric depth of about 887 g/cm{sup 2}. The geomagnetic cutoff is 4.5 GV/c. The charge ratio of positive and negative muons and the proton to muon ratio have been determined. These observations will also be compared with data collected at a higher latitude using the same basic apparatus.

  10. Estimation of strong ground motion

    International Nuclear Information System (INIS)

    Watabe, Makoto

    1993-01-01

    Fault model has been developed to estimate a strong ground motion in consideration of characteristics of seismic source and propagation path of seismic waves. There are two different approaches in the model. The first one is a theoretical approach, while the second approach is a semi-empirical approach. Though the latter is more practical than the former to be applied to the estimation of input motions, it needs at least the small-event records, the value of the seismic moment of the small event and the fault model of the large event

  11. Global trends on local grounds

    DEFF Research Database (Denmark)

    Steensen, Jette Johanne

    2006-01-01

    Collection of papers produced by tutors involved in a master´s degree course for teacher in Ethiopia offers an important challenge to the dominant neo-liberal agenda that has taken over educational reform throughtout the world. The project was based on the practice of critical practitioner inquiry...... and built upon similar efforts in Namibia in the 1990s. Steensen´s contribution stresses that any educational system will have to lie firmly on local grounds, that international trends must be analysed strategically as well as critically and that such analysis, for example through Critical Practitioner...

  12. Implications of ground water chemistry and flow patterns for earthquake studies.

    Science.gov (United States)

    Guangcai, Wang; Zuochen, Zhang; Min, Wang; Cravotta, Charles A; Chenglong, Liu

    2005-01-01

    Ground water can facilitate earthquake development and respond physically and chemically to tectonism. Thus, an understanding of ground water circulation in seismically active regions is important for earthquake prediction. To investigate the roles of ground water in the development and prediction of earthquakes, geological and hydrogeological monitoring was conducted in a seismogenic area in the Yanhuai Basin, China. This study used isotopic and hydrogeochemical methods to characterize ground water samples from six hot springs and two cold springs. The hydrochemical data and associated geological and geophysical data were used to identify possible relations between ground water circulation and seismically active structural features. The data for delta18O, deltaD, tritium, and 14C indicate ground water from hot springs is of meteoric origin with subsurface residence times of 50 to 30,320 years. The reservoir temperature and circulation depths of the hot ground water are 57 degrees C to 160 degrees C and 1600 to 5000 m, respectively, as estimated by quartz and chalcedony geothermometers and the geothermal gradient. Various possible origins of noble gases dissolved in the ground water also were evaluated, indicating mantle and deep crust sources consistent with tectonically active segments. A hard intercalated stratum, where small to moderate earthquakes frequently originate, is present between a deep (10 to 20 km), high-electrical conductivity layer and the zone of active ground water circulation. The ground water anomalies are closely related to the structural peculiarity of each monitoring point. These results could have implications for ground water and seismic studies in other seismogenic areas.

  13. Ground cross-modal impedance as a tool for analyzing ground/plate interaction and ground wave propagation.

    Science.gov (United States)

    Grau, L; Laulagnet, B

    2015-05-01

    An analytical approach is investigated to model ground-plate interaction based on modal decomposition and the two-dimensional Fourier transform. A finite rectangular plate subjected to flexural vibration is coupled with the ground and modeled with the Kirchhoff hypothesis. A Navier equation represents the stratified ground, assumed infinite in the x- and y-directions and free at the top surface. To obtain an analytical solution, modal decomposition is applied to the structure and a Fourier Transform is applied to the ground. The result is a new tool for analyzing ground-plate interaction to resolve this problem: ground cross-modal impedance. It allows quantifying the added-stiffness, added-mass, and added-damping from the ground to the structure. Similarity with the parallel acoustic problem is highlighted. A comparison between the theory and the experiment shows good matching. Finally, specific cases are investigated, notably the influence of layer depth on plate vibration.

  14. Electric dipole ordering in alkali-cyanides: NaCN and KCN

    International Nuclear Information System (INIS)

    Koiller, B.; Davidovich, M.A.; Carmo, L.C.S. do; Luety, F.

    1983-01-01

    A simple model for the low temperature electrically ordered state of NaCN and KCN is presented. The model takes into account electric dipole dressing effects which include cationic displacements determined experimentally. The ground state structure and the calculated values for the local electric fields are in fair agreement with experimental results. A parametrization for the elastic potencial confirms the plausibility of these model. (Author) [pt

  15. Optimized design of micromachined electric field mills to maximize electrostatic field sensitivity

    OpenAIRE

    Zhou, Yu; Shafai, Cyrus

    2016-01-01

    This paper describes the design optimization of a micromachined electric field mill, in relation to maximizing its output signal. The cases studied are for a perforated electrically grounded shutter vibrating laterally over sensing electrodes. It is shown that when modeling the output signal of the sensor, the differential charge on the sense electrodes when exposed to vs. visibly shielded from the incident electric field must be considered. Parametric studies of device dimensions show that t...

  16. Grounding word learning in space.

    Directory of Open Access Journals (Sweden)

    Larissa K Samuelson

    Full Text Available Humans and objects, and thus social interactions about objects, exist within space. Words direct listeners' attention to specific regions of space. Thus, a strong correspondence exists between where one looks, one's bodily orientation, and what one sees. This leads to further correspondence with what one remembers. Here, we present data suggesting that children use associations between space and objects and space and words to link words and objects--space binds labels to their referents. We tested this claim in four experiments, showing that the spatial consistency of where objects are presented affects children's word learning. Next, we demonstrate that a process model that grounds word learning in the known neural dynamics of spatial attention, spatial memory, and associative learning can capture the suite of results reported here. This model also predicts that space is special, a prediction supported in a fifth experiment that shows children do not use color as a cue to bind words and objects. In a final experiment, we ask whether spatial consistency affects word learning in naturalistic word learning contexts. Children of parents who spontaneously keep objects in a consistent spatial location during naming interactions learn words more effectively. Together, the model and data show that space is a powerful tool that can effectively ground word learning in social contexts.

  17. Common Ground Between Three Cultures

    Directory of Open Access Journals (Sweden)

    Gloria Dunnivan

    2009-12-01

    Full Text Available The Triwizard program with Israel brought together students from three different communities: an Israeli Arab school, an Israeli Jewish school, and an American public school with few Jews and even fewer Muslims. The two Israeli groups met in Israel to find common ground and overcome their differences through dialogue and understanding. They communicated with the American school via technology such as video-conferencing, Skype, and emails. The program culminated with a visit to the U.S. The goal of the program was to embark upon a process that would bring about intercultural awareness and acceptance at the subjective level, guiding all involved to develop empathy and an insider's view of the other's culture. It was an attempt to have a group of Israeli high school students and a group of Arab Israeli students who had a fearful, distrustful perception of each other find common ground and become friends. TriWizard was designed to have participants begin a dialogue about issues, beliefs, and emotions based on the premise that cross-cultural training strategies that are effective in changing knowledge are those that engage the emotions, and actively develop empathy and an insider's views of another culture focused on what they have in common. Participants learned that they could become friends despite their cultural differences.

  18. Extensive air showers, lightnings and thunderstorm ground enhancements

    International Nuclear Information System (INIS)

    Chilingarian, A.; Hovsepyan, G.; Kozliner, L.

    2016-01-01

    For the lightning research, we monitor the particle fluxes from thunderclouds, the so called Thunderstorm Ground Enhancements (TGEs) initiated by the runaway electrons, and Extensive Air Showers (EASs) originated from high energy protons or fully stripped nuclei that enter the Earth’s atmosphere. Besides, we monitor the near-surface electric field and the atmospheric discharges with the help of a network of electric field mills. The Aragats “electron accelerator” produced plenty of TGE and lightning events in spring 2015. Using 1-sec time series, we investigated the relation of lightnings and particle fluxes. Lightning flashes often terminated the particle flux; during some of TGEs the lightning would terminate the particle flux 3 times after successive recovery. It was postulated that a lightning terminates a particle flux mostly in the beginning of TGE or on the decay phase of it; however, we observed two events (19 October 2013 and 20 April 2015) when the huge particle flux was terminated just on a maximum of its development. We discuss the possibility that a huge EAS facilitates lightning leader to find its path to the ground. (author)

  19. Novel Electrically Small Spherical Electric Dipole Antenna

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    2010-01-01

    This paper introduces a novel electrically small spherical meander antenna. Horizontal sections of the meander are composed of wire loops, radii of which are chosen so that the whole structure is conformal to a sphere of radius a. To form the meander the loops are connected by wires at a meridian...

  20. Ground penetrating radar system and method for detecting an object on or below a ground surface

    NARCIS (Netherlands)

    De Jongth, R.; Yarovoy, A.; Schukin, A.

    2001-01-01

    Ground penetrating radar system for detecting objects (17) on or below a ground surface (18), comprising at least one transmit antenna (13) having a first foot print (14) at the ground surface, at least one receive antenna (15) having a second foot print (16) at the ground surface, and processing

  1. Radioactive waste disposal via electric propulsion

    Science.gov (United States)

    Burns, R. E.

    1975-01-01

    It is shown that space transportation is a feasible method of removal of radioactive wastes from the biosphere. The high decay heat of the isotopes powers a thermionic generator which provides electrical power for ion thrust engines. The massive shields (used to protect ground and flight personnel) are removed in orbit for subsequent reuse; the metallic fuel provides a shield for the avionics that guides the orbital stage to solar system escape. Performance calculations indicate that 4000 kg. of actinides may be removed per Shuttle flight. Subsidiary problems - such as cooling during ascent - are discussed.

  2. Geotechnical Applications of the Self-Potential (SP) Method. Report 2. The Use of Self Potential to Detect Ground-Water Flow in Karst

    Science.gov (United States)

    1989-05-01

    precipitation are major variables influencing SP data. An automated data collection system was devieed enc’used for:G v - taekeso JIA)-long-term...Researchers have used other geophysical techniques (electrical resis- tivity, seismic refraction, gravimetry , terrain conductivity, ground probing...artificial water injections (recharge) into sinkholes, dye trac- ing, and monitoring of soil temperature, precipitation , ground-water conduc- tivity, and

  3. Transitions in midwestern ground water law

    International Nuclear Information System (INIS)

    Bowman, J.A.; Clark, G.R.

    1989-01-01

    The evolution of ground-water law in eight states in the Midwest (Illinois, Indiana, Iowa, Michigan, Minnesota, Missouri, Ohio, and Wisconsin) is examined, and a review of transitions in ground-water doctrines is presented. Two underlying themes in changing ground-water management are communicated. First, ground-water law is evolving from private property rules of capture based on the absolute ownership doctrines to rules requiring conservation and sharing of ground water as a public resource. Second, in both courts and state legislatures, a proactive role of ground-water management is emerging, again, with an emphasis on sharing. Both of these trends are apparent in the Midwest. In the last decade midwestern states have (1) seen significant shifts in court decisions on ground-water use with greater recognition of the reciprocal or mutually dependent nature of ground-water rights, and (2) seen increased legislative development of comprehensive ground-water management statutes that emphasize the reciprocal liabilities of ground-water use. These trends are examined and ground-water management programs discussed for eight states in the Midwest

  4. Electricity from wetlands

    NARCIS (Netherlands)

    Wetser, K.

    2016-01-01

    Sustainable electricity generation by the plant microbial fuel cell

    Fossil fuels are currently the main source of electricity production. Combustion of fossil fuels causes air pollution severely affecting human health and nature. This results in an increasing demand for

  5. Unified electricity market

    International Nuclear Information System (INIS)

    Anon

    2011-01-01

    A unified European electricity market means a unification and harmonisation of functioning of the national electricity market into one European Market or into one entity. It gives an opportunity to Slovenske elektrarne to open room for their wider activity within Europe where common rules for cross-boarder trade and markets functioning will apply. (author)

  6. The electricity market

    International Nuclear Information System (INIS)

    2015-01-01

    After a first part proposing predictions for electricity production and consumption for 2016, for the turnovers of electricity suppliers and producers, an indication of important recent important events regarding enterprises belonging to the sector, and a dashboard of the sector activity, an annual report proposes a detailed overview of trends and of the competition context for the electricity market. It identifies the main market opportunities for electricity suppliers, identifies eight determining factors for the sector activity, gives an overview of the sector context evolution between 2004 and 2014 (temperatures, rainfalls, manufacturing industry production, housing and office building stock, projected housing and office building). It analyses the evolution of the sector activity by presenting and commenting various activity indicators and financial performance of electricity producers. It analyses the sector economic structure: evolution of the economic fabric, presentation of various structural characteristics (cross-border exchanges, production capacities per energy source, nuclear plant fleet, thermal plant fleet, location, electricity supply market). It proposes a presentation of the various actors and of their respective market shares, and presentations of groups, electricity suppliers, and electricity producers. It indicates highlights and presents various rankings of the main enterprises in 2014

  7. Electric industry in 1992

    International Nuclear Information System (INIS)

    1993-01-01

    The production of electricity in 1992 is analyzed. The increase (0,4%) of electricity consumption and the decrease of its production are the main characteristics of 1993 in Spain. These aspect with the UNESA data are studied. In 1992 30000 Kw of 216.505 Kw total were produced by wind mills

  8. Electric power annual, 1991

    International Nuclear Information System (INIS)

    1993-01-01

    The Electric Power Annual is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels; Energy Information Administration (EIA); US Department of Energy. The 1991 edition has been enhanced to include statistics on electric utility demand-side management and nonutility supply. ''The US Electric Power Industry at a Glance'' section presents a profile of the electric power industry ownership and performance, and a review of key statistics for the year. Subsequent sections present data on generating capability, including proposed capability additions; net generation; fossil-fuel statistics; electricity sales, revenue, and average revenue per kilowatthour sold; financial statistics; environmental statistics; electric power transactions; demand-side management; and nonutility power producers. In addition, the appendices provide supplemental data on major disturbances and unusual occurrences in US electricity power systems. Each section contains related text and tables and refers the reader to the appropriate publication that contains more detailed data on the subject matter. Monetary values in this publication are expressed in nominal terms

  9. Electricity information 1994

    International Nuclear Information System (INIS)

    1995-01-01

    Basic statistics on the electricity and heat production in OECD countries are compiled by the International Energy Agency. The statistics cover annual OECD data for prices, production, consumption and trade. Detailed electricity and heat statistics are also presented for each OECD countries. (O.L.). 34 figs., 36 tabs

  10. Sustainable Use of Electricity

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen

    1998-01-01

    An overview is presented of the need for keeping electricity consumption low, including a suggested definition of sustainable development. Specific attention is devoted to present and future electricity production´s contribution to the environmental problems. Prognoses are shown from before any...

  11. The harnessing of electricity

    International Nuclear Information System (INIS)

    Valencia Giraldo, Asdrubal

    1992-01-01

    A brief summary is presented on the evolution of electricity knowledge from antiquity to our days. At the same time the growth of its practical applications, i. e. the electrical industry, is described, as well as its technical, scientific, economic and social consequences

  12. Electric Vehicle Battery Challenge

    Science.gov (United States)

    Roman, Harry T.

    2014-01-01

    A serious drawback to electric vehicles [batteries only] is the idle time needed to recharge their batteries. In this challenge, students can develop ideas and concepts for battery change-out at automotive service stations. Such a capability would extend the range of electric vehicles.

  13. Hawaii Electric System Reliability

    Energy Technology Data Exchange (ETDEWEB)

    Loose, Verne William [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Silva Monroy, Cesar Augusto [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2012-08-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers’ views of reliability “worth” and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers’ views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.

  14. Hawaii electric system reliability.

    Energy Technology Data Exchange (ETDEWEB)

    Silva Monroy, Cesar Augusto; Loose, Verne William

    2012-09-01

    This report addresses Hawaii electric system reliability issues; greater emphasis is placed on short-term reliability but resource adequacy is reviewed in reference to electric consumers' views of reliability %E2%80%9Cworth%E2%80%9D and the reserve capacity required to deliver that value. The report begins with a description of the Hawaii electric system to the extent permitted by publicly available data. Electrical engineering literature in the area of electric reliability is researched and briefly reviewed. North American Electric Reliability Corporation standards and measures for generation and transmission are reviewed and identified as to their appropriateness for various portions of the electric grid and for application in Hawaii. Analysis of frequency data supplied by the State of Hawaii Public Utilities Commission is presented together with comparison and contrast of performance of each of the systems for two years, 2010 and 2011. Literature tracing the development of reliability economics is reviewed and referenced. A method is explained for integrating system cost with outage cost to determine the optimal resource adequacy given customers' views of the value contributed by reliable electric supply. The report concludes with findings and recommendations for reliability in the State of Hawaii.

  15. French electricity report 2003

    International Nuclear Information System (INIS)

    2003-01-01

    In terms of electricity, 2003 saw a great increase in electricity consumption in France. This increase was accompanied by a global progression in cross-border commercial exchanges, but a notable drop in the net export balance for physical exchanges between France and its neighbouring countries

  16. Pulsed electric fields

    Science.gov (United States)

    The concept of pulsed electric fields (PEF) was first proposed in 1967 to change the behavior or microorganisms. The electric field phenomenon was identified as membrane rupture theory in the 1980s. Increasing the membrane permeability led to the application of PEF assisted extraction of cellular co...

  17. Transonic and supersonic ground effect aerodynamics

    Science.gov (United States)

    Doig, G.

    2014-08-01

    A review of recent and historical work in the field of transonic and supersonic ground effect aerodynamics has been conducted, focussing on applied research on wings and aircraft, present and future ground transportation, projectiles, rocket sleds and other related bodies which travel in close ground proximity in the compressible regime. Methods for ground testing are described and evaluated, noting that wind tunnel testing is best performed with a symmetry model in the absence of a moving ground; sled or rail testing is ultimately preferable, though considerably more expensive. Findings are reported on shock-related ground influence on aerodynamic forces and moments in and accelerating through the transonic regime - where force reversals and the early onset of local supersonic flow is prevalent - as well as more predictable behaviours in fully supersonic to hypersonic ground effect flows.

  18. Design of power cable grounding wire anti-theft monitoring system

    Science.gov (United States)

    An, Xisheng; Lu, Peng; Wei, Niansheng; Hong, Gang

    2018-01-01

    In order to prevent the serious consequences of the power grid failure caused by the power cable grounding wire theft, this paper presents a GPRS based power cable grounding wire anti-theft monitoring device system, which includes a camera module, a sensor module, a micro processing system module, and a data monitoring center module, a mobile terminal module. Our design utilize two kinds of methods for detecting and reporting comprehensive image, it can effectively solve the problem of power and cable grounding wire box theft problem, timely follow-up grounded cable theft events, prevent the occurrence of electric field of high voltage transmission line fault, improve the reliability of the safe operation of power grid.

  19. Materials and electricity

    International Nuclear Information System (INIS)

    Jaffee, R.I.

    1986-01-01

    Despite an increase in the intensity of electricity usage, electricity has been reversing its historical trend of reduced cost since 1970 to the point where costs are increasing faster than inflation. Designers and operators on both sides of the meter and the developers of materials from which the electric system is constructed must contribute to the lowering of costs and an increase in reliability for the generation, transmission and distribution, and utilization of electricity. Four specific cases illustrate the role of materials/process improvements to this end. The examples highlight the use of forged or welded integral rotors, improvements in the heat rate of coal-fired plants through higher steam conditions and reduced heat losses, reduced losses through amorphous steel cores for transformers, and reduced ac electric motor losses through silicon variable speed drives. 37 references, 27 figures, 9 tables

  20. Electric automobile: Commercialization prospects

    International Nuclear Information System (INIS)

    Tabasso, L.

    1992-01-01

    Performance results during one-month test driving of a small FIAT car (normally equipped with a 30-45 Hp internal combustion engine), retrofitted to operate with a set of electric batteries delivering 15 Hp, demonstrated that, unless the design of an electric car's transmission and control systems are based completely on electric power operation, the vehicle loses its competitiveness with conventional cars. Making reference to the findings of an ENEA (Italian Agency for New Technology, Energy and Environment) electric powered vehicle R ampersand D program, this paper assesses the feasibility of electric powered vehicles and points out their major drawbacks: battery volume, weight, cost and recharging requirements in densely populated urban environments. The paper also notes that mass conversion to these vehicles by itself will not solve the urban traffic congestion problem for which optimum traffic control and parking areas are required

  1. Electricity Storage. Technology Brief

    Energy Technology Data Exchange (ETDEWEB)

    Simbolotti, G. [Italian National Agency for New Technologies, Energy and Sustainable Economic Development ENEA, Rome (Italy); Kempener, R. [International Renewable Energy Agency IRENA, Bonn (Germany)

    2012-04-15

    Electricity storage is a key technology for electricity systems with a high share of renewables as it allows electricity to be generated when renewable sources (i.e. wind, sunlight) are available and to be consumed on demand. It is expected that the increasing price of fossil fuels and peak-load electricity and the growing share of renewables will result in electricity storage to grow rapidly and become more cost effective. However, electricity storage is technically challenging because electricity can only be stored after conversion into other forms of energy, and this involves expensive equipment and energy losses. At present, the only commercial storage option is pumped hydro power where surplus electricity (e.g. electricity produced overnight by base-load coal or nuclear power) is used to pump water from a lower to an upper reservoir. The stored energy is then used to produce hydropower during daily high-demand periods. Pumped hydro plants are large-scale storage systems with a typical efficiency between 70% and 80%, which means that a quarter of the energy is lost in the process. Other storage technologies with different characteristics (i.e. storage process and capacity, conversion back to electricity and response to power demand, energy losses and costs) are currently in demonstration or pre-commercial stages and discussed in this brief report: Compressed air energy storage (CAES) systems, Flywheels; Electrical batteries; Supercapacitors; Superconducting magnetic storage; and Thermal energy storage. No single electricity storage technology scores high in all dimensions. The technology of choice often depends on the size of the system, the specific service, the electricity sources and the marginal cost of peak electricity. Pumped hydro currently accounts for 95% of the global storage capacity and still offers a considerable expansion potential but does not suit residential or small-size applications. CAES expansion is limited due to the lack of suitable

  2. Ontario electricity industry restructuring

    International Nuclear Information System (INIS)

    1999-01-01

    The objective of Ontario's electricity industry restructuring was described as an effort to enhance Ontario's competitiveness. It is believed that restructuring can be accomplished without an increase in electricity rates. In a series of charts, the report provides the timeline of restructuring from the time of the Macdonald report in 1995 to the beginning of open competition in Ontario electricity markets. It oulines the principles underlying the financial restructuring and the financial results of restructuring, including the size of the stranded debt ($ 7.8 billion). It lists the changes that have occurred since October 1998, explains some key factors in valuing the successor companies and profiles the Ontario Electricity Financial Corporation. Restructuring of the industry is expected to have a neutral to positive impact on Ontario's fiscal position. The residual stranded debt of $7.8 billion will be retired through revenues generated by the electricity sector, without recourse to the Provincial Treasury. 9 figs

  3. Electric power monthly

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Sandra R.; Johnson, Melvin; McClevey, Kenneth; Calopedis, Stephen; Bolden, Deborah

    1992-05-01

    The Electric Power Monthly is prepared by the Survey Management Division; Office of Coal, Nuclear, Electric and Alternate Fuels, Energy Information Administration (EIA), Department of Energy. This publication provides monthly statistics at the national, Census division, and State levels for net generation, fuel consumption, fuel stocks, quantity and quality of fuel, cost of fuel, electricity sales, revenue, and average revenue per kilowatthour of electricity sold. Data on net generation, fuel consumption, fuel stocks, quantity and cost of fuel are also displayed for the North American Electric Reliability Council (NERC) regions. Additionally, statistics by company and plant are published in the EPM on capability of new plants, new generation, fuel consumption, fuel stocks, quantity and quality of fuel, and cost of fuel.

  4. Electricity/oil substitution

    International Nuclear Information System (INIS)

    Melvin, J.G.

    1980-09-01

    The extent to which electricity could substitute for imported oil in Canada is assessed and it is concluded that the bulk of projected oil imports could be displaced. This substitution of electricity for oil could be largely completed within two decades, with existing technology, using Canadian resources. The substitution of electricity for imported oil would result in relatively low energy costs and would stimulate economic growth. Energy self-sufficiency through the substitution of electricity for oil is uniquely a Canadian option; it is not open to other industrial countries. The option exists because of Canada's resources of oil sands for essential liquid fuels, hydraulic and nuclear electrical potential, and natural gas as an interim source of energy. While other countries face an energy crisis due to declining supplies of oil, Canada faces opportunities. The policies of Federal and Provincial governments, as perceived by individual decision makers, will have a major influence on Canada's ability to realize opportunities. (auth)

  5. Earth's electric field

    International Nuclear Information System (INIS)

    Kelley, M.C.

    1978-01-01

    The earth becomes charged during thunderstorm activity and discharges through the weak conducting atmosphere. Balloon and rocket studies infer that a high altitude electric field penetrates virtually unattenuated through the atmosphere, at least as far as balloon heights. The field has two primary sources. At low and mid latitudes, interaction between the earth's magnetic field and the neutral wind creates electric fields. At latitudes above 60 0 , the high altitude electrical structure is dominated by the interaction between the solar wind and the earth's magnetic field. The auroral light is emitted by atmospheric atoms and molecules excited by electrons with potentials of many thousands volts. The potentials are induced by the solar wind. Recent satellite data shows that the electrons get this energy by passing through a localized electric field about 6000 km above the auroral zone. Several rocket and satellite experiments used to study the earth's electric field are discussed

  6. Electricity Bill [second reading

    International Nuclear Information System (INIS)

    Hooper, G.; Williams, C.C.P.; Ezra, D.

    1989-01-01

    The Parliamentary Under-Secretary at the Department of Energy introduced the second reading of the Electricity Bill which provides for the restructuring and privatisation of the electricity supply industry throughout Great Britain. Three features at the heart of the Government's proposals are mentioned - first that the proposals will promote competition in electricity generation and supply of electricity so there will be a downward pressure on costs and prices, second is a new deal for customers and third is the security of electricity supply which will be ensured by the diversity of suppliers. The benefits of the scheme are outlined and then specific details of the Bill are considered. The debate which followed lasted six hours and is reported verbatim. The issues raised included environmental effects, efficiency, energy conservation, research and development and investment. (UK)

  7. Ground Operations Autonomous Control and Integrated Health Management

    Science.gov (United States)

    Daniels, James

    2014-01-01

    The Ground Operations Autonomous Control and Integrated Health Management plays a key role for future ground operations at NASA. The software that is integrated into this system is called G2 2011 Gensym. The purpose of this report is to describe the Ground Operations Autonomous Control and Integrated Health Management with the use of the G2 Gensym software and the G2 NASA toolkit for Integrated System Health Management (ISHM) which is a Computer Software Configuration Item (CSCI). The decision rationale for the use of the G2 platform is to develop a modular capability for ISHM and AC. Toolkit modules include knowledge bases that are generic and can be applied in any application domain module. That way, there's a maximization of reusability, maintainability, and systematic evolution, portability, and scalability. Engine modules are generic, while application modules represent the domain model of a specific application. Furthermore, the NASA toolkit, developed since 2006 (a set of modules), makes it possible to create application domain models quickly, using pre-defined objects that include sensors and components libraries for typical fluid, electrical, and mechanical systems.

  8. Mission aware energy saving strategies for Army ground vehicles

    Science.gov (United States)

    Dattathreya, Macam S.

    Fuel energy is a basic necessity for this planet and the modern technology to perform many activities on earth. On the other hand, quadrupled automotive vehicle usage by the commercial industry and military has increased fuel consumption. Military readiness of Army ground vehicles is very important for a country to protect its people and resources. Fuel energy is a major requirement for Army ground vehicles. According to a report, a department of defense has spent nearly $13.6 billion on fuel and electricity to conduct ground missions. On the contrary, energy availability on this plant is slowly decreasing. Therefore, saving energy in Army ground vehicles is very important. Army ground vehicles are embedded with numerous electronic systems to conduct missions such as silent and normal stationary surveillance missions. Increasing electrical energy consumption of these systems is influencing higher fuel consumption of the vehicle. To save energy, the vehicles can use any of the existing techniques, but they require complex, expensive, and time consuming implementations. Therefore, cheaper and simpler approaches are required. In addition, the solutions have to save energy according to mission needs and also overcome size and weight constraints of the vehicle. Existing research in the current literature do not have any mission aware approaches to save energy. This dissertation research proposes mission aware online energy saving strategies for stationary Army ground vehicles to save energy as well as to meet the electrical needs of the vehicle during surveillance missions. The research also proposes theoretical models of surveillance missions, fuzzy logic models of engine and alternator efficiency data, and fuzzy logic algorithms. Based on these models, two energy saving strategies are proposed for silent and normal surveillance type of missions. During silent mission, the engine is on and batteries power the systems. During normal surveillance mission, the engine is

  9. Swiss electricity statistics 2001

    International Nuclear Information System (INIS)

    2002-01-01

    This publication by the Association of Swiss Electricity Enterprises for the Swiss Federal Office of Energy (SFOE) provides statistical information on electricity production, trading and consumption in Switzerland in 2001. Apart from a general overview of the Swiss electricity supply that includes details on power generation, energy transfer with neighbouring countries and data on prices, average consumption and capital investment, the publication also includes graphical representations of electrical energy flows in and out of Switzerland. Tables of data give information on electricity production, import and export for the years 1950 to 2001, the data being supplied for each hydrological year and the summer and winter seasons respectively. The production of power in Switzerland is examined in detail. Details are given on the development of production capacities and the various means of production together with their respective shares of total production. Further tables and diagrams provide information on power production in various geographical regions and on the management of pumped storage hydro-electricity schemes. A further chapter deals in detail with the consumption of electricity, its growth between 1984 and 2001 and its use in various sectors. A fifth chapter examines electricity consumption, generation, import and export on single, typical days, presenting data in tables and diagrams. The next chapter examines energy transfer with foreign countries and the trading structures involved. The final two chapters cover new and future power generation capacities and the economic considerations involved in the supply of electricity chapters cover new and future power generation capacities and the economic considerations involved in the supply of electricity

  10. Evaluation of the Atmospheric Boundary-Layer Electrical Variability

    Science.gov (United States)

    Anisimov, Sergey V.; Galichenko, Sergey V.; Aphinogenov, Konstantin V.; Prokhorchuk, Aleksandr A.

    2017-12-01

    Due to the chaotic motion of charged particles carried by turbulent eddies, electrical quantities in the atmospheric boundary layer (ABL) have short-term variability superimposed on long-term variability caused by sources from regional to global scales. In this study the influence of radon exhalation rate, aerosol distribution and turbulent transport efficiency on the variability of fair-weather atmospheric electricity is investigated via Lagrangian stochastic modelling. For the mid-latitude lower atmosphere undisturbed by precipitation, electrified clouds, or thunderstorms, the model is capable of reproducing the diurnal variation in atmospheric electrical parameters detected by ground-based measurements. Based on the analysis of field observations and numerical simulation it is found that the development of the convective boundary layer, accompanied by an increase in turbulent kinetic energy, forms the vertical distribution of radon and its decaying short-lived daughters to be approximately coincident with the barometric law for several eddy turnover times. In the daytime ABL the vertical distribution of atmospheric electrical conductivity tends to be uniform except within the surface layer, due to convective mixing of radon and its radioactive decay products. At the same time, a decrease in the conductivity near the ground is usually observed. This effect leads to an enhanced ground-level atmospheric electric field compared to that normally observed in the nocturnal stably-stratified boundary layer. The simulation showed that the variability of atmospheric electric field in the ABL associated with internal origins is significant in comparison to the variability related to changes in global parameters. It is suggested that vertical profiles of electrical quantities can serve as informative parameters on ABL turbulent dynamics and can even more broadly characterize the state of the environment.

  11. Radon classification of building ground

    International Nuclear Information System (INIS)

    Slunga, E.

    1988-01-01

    The Laboratories of Building Technology and Soil Mechanics and Foundation Engineering at the Helsinki University of Technology in cooperation with The Ministry of the Environment have proposed a radon classification for building ground. The proposed classification is based on the radon concentration in soil pores and on the permeability of the foundation soil. The classification includes four radon classes: negligible, normal, high and very high. Depending on the radon class the radon-technical solution for structures is chosen. It is proposed that the classification be done in general terms in connection with the site investigations for the planning of land use and in more detail in connection with the site investigations for an individual house. (author)

  12. Ferromagnetism controlled by electric field in tilted phosphorene nanoribbon

    Science.gov (United States)

    Farooq, M. Umar; Hashmi, Arqum; Hong, Jisang

    2016-01-01

    Study on phosphorene nanoribbon was mostly focused on zigzag and armchair structures and no ferromagnetic ground state was observed in these systems. Here, we investigated the magnetic property of tilted black phosphorene nanoribbons (TPNRs) affected by an external electric field. We also studied the edge passivation effect on the magnetism and thermal stability of the nanoribbons. The pure TPNR displayed an edge magnetic state, but it disappeared in the edge reconstructed TPNR due to the self-passivation. In addition, we found that the bare TPNR was mechanically unstable because an imaginary vibration mode was obtained. However, the imaginary vibration mode disappeared in the edge passivated TPNRs. No edge magnetism was observed in hydrogen and fluorine passivated TPRNs. In contrast, the oxygen passivated TPNR was more stable than the pure TPNR and the edge-to-edge antiferromagntic (AFM) ground state was obtained. We found that the magnetic ground state could be tuned by the electric field from antiferromagnetic (AFM) to ferromagnetic (FM) ground state. Interestingly, the oxygen passivated TPNR displayed a half-metallic state at a proper electric field in both FM and AFM states. This finding may provoke an intriguing issue for potential spintronics application using the phosphorene nanoribbons. PMID:27189417

  13. Navigating the grounded theory terrain. Part 1.

    Science.gov (United States)

    Hunter, Andrew; Murphy, Kathy; Grealish, Annmarie; Casey, Dympna; Keady, John

    2011-01-01

    The decision to use grounded theory is not an easy one and this article aims to illustrate and explore the methodological complexity and decision-making process. It explores the decision making of one researcher in the first two years of a grounded theory PhD study looking at the psychosocial training needs of nurses and healthcare assistants working with people with dementia in residential care. It aims to map out three different approaches to grounded theory: classic, Straussian and constructivist. In nursing research, grounded theory is often referred to but it is not always well understood. This confusion is due in part to the history of grounded theory methodology, which is one of development and divergent approaches. Common elements across grounded theory approaches are briefly outlined, along with the key differences of the divergent approaches. Methodological literature pertaining to the three chosen grounded theory approaches is considered and presented to illustrate the options and support the choice made. The process of deciding on classical grounded theory as the version best suited to this research is presented. The methodological and personal factors that directed the decision are outlined. The relative strengths of Straussian and constructivist grounded theories are reviewed. All three grounded theory approaches considered offer the researcher a structured, rigorous methodology, but researchers need to understand their choices and make those choices based on a range of methodological and personal factors. In the second article, the final methodological decision will be outlined and its research application described.

  14. Electricity from biogas

    International Nuclear Information System (INIS)

    Augenstein, D.; Benemann, J.; Hughes, E.

    1994-01-01

    Biogas is a medium-Btu methane and carbon dioxide mix produced by bacterial decomposition of organic matter. Its sources include landfills, waste water sludges, and animal wastes. It can fuel energy applications, of which electricity generation is a frequently-preferred option. The greatest current U.S. biogas recovery and energy use is at landfills, where biogas at about 80 landfill sites fuels a total of approximately 300 MWe. Wastewater treatment plants and confined animal waste management systems support additional electric power production. Generation of electricity from biogas can present difficulties due to the generally small scale of the generating facility, variable energy content of the gas, fluctuating availability, contaminant problems, and often-demanding control needs. However, such difficulties are being successfully addressed and economics for electricity generation are often favorable as biogas can be essentially open-quotes freeclose quotes fuel. Biogas recovery and use has the additional advantage of mitigating a potent greenhouse gas. Biogas from U.S. landfills alone could fuel about 1% of U.S. electrical generation while giving climate change benefit equivalent to reducing CO 2 emissions in the electricity sector by more than 10%. Growth in landfill gas use will be facilitated by recent regulations, advances in equipment, and improved management techniques such as open-quotes controlled landfillingclose quotes. The potential for biogas recovery and electricity production from sewage sludges, animal wastes and other organic resources such as agricultural residues is uncertain but probably exceeds the estimate for landfills

  15. Electricity and the environment

    International Nuclear Information System (INIS)

    1991-09-01

    The objective of the Symposium was to provide a comprehensive assessment of the environmental and health factors as well as the economic factors involved in supplying electricity services, and to suggest a framework within which these issues should be taken into account in making future plans and decisions on electricity production and use. The potential role of different ways of meeting electricity service requirements was also to be analysed, taking into consideration both demand side and supply side options in the light of their comparative economic, environmental and health related impacts. Four Expert Groups considered key issues: the environmental implications of energy and electricity supply and demand; energy sources and technologies for electricity generation; comparative environmental and health effects of different energy systems for electricity generation; and the incorporation of environmental and health impacts into policy, planning and decision making for the electricity sector. During the Symposium, keynote addresses and invited papers presented by leading experts and policy makers provided additional related information. In this volume the background papers are presented. The proceedings have been published separately, and the individual papers in both volumes have been indexed separately for INIS. Refs, figs and tabs

  16. Electricity and the environment

    International Nuclear Information System (INIS)

    1991-01-01

    The objective of the Symposium was to provide a comprehensive assessment of the environmental and health factors as well as the economic factors involved in supplying electricity services, and to suggest a framework within which these issues should be taken into account in making future plans and decisions on electricity production and use. The potential role of different ways of meeting electricity service requirements was also to be analysed, taking into consideration both demand side and supply side options in the light of their comparative economic, environmental and health related impacts. Four Expert Groups considered key issues: the environmental implications of energy and electricity supply and demand; energy sources and technologies for electricity generation; comparative environmental and health effects of different energy systems for electricity generation; and the incorporation of environmental and health impacts into policy, planning and decision making for the electricity sector. During the Symposium, keynote addresses and invited papers presented by leading experts and policy makers provided additional related information. The Proceedings contain all the addresses and papers presented (which are also indexed separately) together with summaries of the discussions that took place. The Key Issues Papers are presented in a separate publication. Refs, figs and tabs

  17. Ground-Wave Propagation Effects on Transmission Lines through Error Images

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-07-01

    Full Text Available Electromagnetic transient calculation of overhead transmission lines is strongly influenced by the natural resistivity of the ground. This varies from 1-10K (Ω·m depending on several media factors and on the physical composition of the ground. The accuracy on the calculation of a system transient response depends in part in the ground return model, which should consider the line geometry, the electrical resistivity and the frequency dependence of the power source. Up to date, there are only a few reports on the specialized literature about analyzing the effects produced by the presence of an imperfectly conducting ground of transmission lines in a transient state. A broad range analysis of three of the most often used ground-return models for calculating electromagnetic transients of overhead transmission lines is performed in this paper. The behavior of modal propagation in ground is analyzed here into effects of first and second order. Finally, a numerical tool based on relative error images is proposed in this paper as an aid for the analyst engineer to estimate the incurred error by using approximate ground-return models when calculating transients of overhead transmission lines.

  18. Colloid Detection in Natural Ground Water from Ruprechtov by Laser-Induced Breakdown Detection

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, W.; Geckeis, H.; Goetz, R. [FZK - Inst. fuer Nukleare Entsorgung, Ka rlsruhe (Germany)]. e-mail: hauser@ine.fzk.de; Noseck, U. [Gesellschaft fuer Anlagen- und Reaktorsicherheit, D-38122 Braunschweig (Germany); Laciok, A. [Nuclear Research Inst. Rez plc, Waste and Environmental Management Dept., Husinec-Rez, PSC 250 68 (Czech Republic)

    2007-06-15

    A borehole ground water sampling system and a mobile laser-induced breakdown detection (LIBD) equipment for colloid detection combined with a geomonitoring unit have been applied to characterize the natural background colloid concentration in ground waters of the Ruprechtov natural analogue site (Czech Republic). Ground water has been sampled using steel cylinders. To minimize artifacts during ground water sampling the contact to atmospheric oxygen has been excluded. The ground water samples collected in this way are transported to the laboratory where they have been connected to a series of flow-through detection cells. Argon gas is used to press the ground water through these detection cells for colloid analysis (LIBD), pH, Eh, electrical conductivity and oxygen content. After the above mentioned analysis additional samples are taken for chemical analysis by ICP-AES, ICP-MS, IC- and DOC-detection. Our data obtained by in-situ- and laboratory- measurements point out that the natural colloid concentration found at the Ruprechtov site is a strong function of the ground water ionic strength. The LIBD determined natural background colloid concentrations found at Ruprechtov are compared with data of studies performed in Aespoe (Sweden) and Grimsel (Switzerland)

  19. Charge analysis on lightning discharges to the ground in Chinese inland plateau (close to Tibet

    Directory of Open Access Journals (Sweden)

    X. Qie

    2000-10-01

    Full Text Available Since the summer of 1996, scientists from China and Japan have conducted a joint observation of natural cloud-to-ground lightning discharges in the Zhongchuan area that is located close to Qinghai-Xizang (Tibet Plateau, China. It has been found that the long-duration of intracloud discharge processes, just before the first return stroke, lasted more than 120 ms for 85% of cloud-to-ground flashes in this area, with a mean duration of 189.7 ms and a maximum of 300 ms. We present the results of charge sources neutralized by four ground flashes and two intracloud discharge processes, just before the first return stroke, by using the data from a 5-site slow antenna network synchronized by GPS with 1 µs time resolution. The result shows that the altitudes of the neutralized negative charge for three negative ground flashes were between 2.7 to 5.4 km above the ground, while that of neutralized positive charges for one positive ground flash and one continuing current process were at about 2.0 km above the ground. The comparison with radar echo showed that the negative discharges initiated in the region greater than 20 dBZ or near the edge of the region with intense echoes greater than 40 dBZ, while positive discharge initiated in the weak echo region.Key words: Meterology and atmospheric dynamics (atmospheric electricity; convective processes; lightning  

  20. Electric power distribution handbook

    CERN Document Server

    Short, Thomas Allen

    2014-01-01

    Of the ""big three"" components of electrical infrastructure, distribution typically gets the least attention. In fact, a thorough, up-to-date treatment of the subject hasn't been published in years, yet deregulation and technical changes have increased the need for better information. Filling this void, the Electric Power Distribution Handbook delivers comprehensive, cutting-edge coverage of the electrical aspects of power distribution systems. The first few chapters of this pragmatic guidebook focus on equipment-oriented information and applications such as choosing transformer connections,