WorldWideScience

Sample records for electrets

  1. Electret radiation detector

    International Nuclear Information System (INIS)

    Kubu, M.

    1981-01-01

    The electret radiation detector consists of 30 to 35% of bee wax and of 65 to 70% of colophony. It is mainly the induction conductivity of charo.es between the dipoles in the electret which is used for detection. In the manufacture of the detector, the average atomic number of the electret can be altered by adding various compounds, such as ZnO, which also increases efficiency for gamma radiation. An alpha or beta emitter can also be built-in in the electret. (B.S.)

  2. Electrets for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    1983-01-01

    Electret dosimetry has been reviewed by Gross. A cylindrical electret ionization-chamber type dosimeter has been studied for X and gamma rays and neutrons. The principle of the dosimeter is electret charge compensation due to ionization in the chamber volume. Electret ionization chambers can be designed with one or more electrets and in various shapes. This study is concerned with a simple system, similar to a cylindrical ionization chamber (sensitive volume: 3,5 cm 3 ) using teflon electrets. Aluminum and lucite were used as wall-materials. Other experiences were performed using chambers without wall, i.e., without defined sensitive volume. The teflon electrets were obtained by Corona discharge in the gas surrounding them. The measurement of the electret charge was made by induction using a co-axial insulated metal chamber connected to an electrometer Keithley 610C. By measuring the charge before and after irradiation it is possible to obtain a calibration curve: charge (Q) versus absorbed dose (D) for the dosimeter. The irradiation setup used was the Beta Secondary Standard System of IPEN calibration laboratory with four beta sources: 90 Sr 90 Y (74 and 1850 MBq), 204 Tl (18,5 MBq) and 147 Pm (518 MBq). In some cases a 85 Kr source was also used. The electrets were tested in different radiation field geometries: electret axis parallel and perpendicular to the field. In conclusion, depending on the wall material and radiation field geometry, the teflon electret detector can be used for different dose interval determinations, using beta radiation

  3. New Devices for Electret Measurement

    Directory of Open Access Journals (Sweden)

    ROMANIUC Ilie

    2013-05-01

    Full Text Available Green energy research have increased in recent decades and interest in unconventional energy production systems is becoming more pronounced. Such unconventional energy generation system is alsobased on electret generator. The electret, is a dielectric material that has a quasi-permanent electric charge. This paper, provides a brief history of the Carnauba wax electret, will be described the process of electret making and will be presented two devices formeasuring the carnauba wax electrets, one of which uses magnetostrictive phenomenon and the second design is achieved with an oscilomotor.

  4. The magnetoactive electret

    Science.gov (United States)

    Monkman, G. J.; Sindersberger, D.; Diermeier, A.; Prem, N.

    2017-07-01

    A magnet which adheres to every surface, not only those of ferromagnetic materials, has hitherto been the domain of science fiction. Now for the first time such a novel device exists. The fusion of a permanently magnetized magnetoactive polymer containing hard magnetic particles and an electret enhanced with ferroelectric particles has resulted in the development of a new smart device—the magnetoactive electret. Magnetoactive electrets can be made to exhibit the usual magnetic properties of permanent magnetism together with the electrostatic properties of electrets. This results in simultaneous magnetoadhesion and electroadhesion forces from the same elastomeric element. The biasing field, needed to avoid discontinuities concerned with transition through the zero point in operating curves, is normally provided by means of either a magnetic or an electric field. This novel technology provides both bias options in a single device.

  5. Parylene-based electret power generators

    International Nuclear Information System (INIS)

    Lo, Hsi-wen; Tai, Yu-Chong

    2008-01-01

    An electret power generator is developed using a new electret made of a charged parylene HT® thin-film polymer. Here, parylene HT® is a room-temperature chemical-vapor-deposited thin-film polymer that is MEMS and CMOS compatible. With corona charge implantation, the surface charge density of parylene HT® is measured as high as 3.69 mC m −2 . Moreover, it is found that, with annealing at 400 °C for 1 h before charge implantation, both the long-term stability and the high-temperature reliability of the electret are improved. For the generator, a new design of the stator/rotor is also developed. The new micro electret generator does not require any sophisticated gap-controlling structure such as tethers. With the conformal coating capability of parylene HT®, it is also feasible to have the electret on the rotors, which is made of either a piece of metal or an insulator. The maximum power output, 17.98 µW, is obtained at 50 Hz with an external load of 80 MΩ. For low frequencies, the generator can harvest 7.7 µW at 10 Hz and 8.23 µW at 20 Hz

  6. A new electret dosemeter for radiotherapy

    International Nuclear Information System (INIS)

    Rodrigues, L.N.

    1985-01-01

    The results obtained with a new plane electret dosemeter for use in Radiotherapy are presented. The working principle of the electret dosemeter in based on the use of the electret field the ion collecting field, similarly to an ionization chamber, and as charge integrator detector. The dosemeter had, initialy, a cylindrical geometry. The results attained with it's calibration curve concerning the sensitivity, the stability and the reproducibility lead to changes in the dosemeter geometry. A plane geometry dosemeter was built in order to increase the useful exposure range. The plane dosemeter sensitivity dependence was measured versus the electret charging conditions, the chamber volume and wall material (aluminium, brass and stainless steel). The stainless steel dosemeter showed the best results. This dosemeter has the following characteristics: sensitivity 10 -13 C/R, volume 0.20 cm 3 . Compared to the Baldwin-Farmer dosemeter, this results are fairly good. A multiple electret dosemeter was developed to monitor the uniformity of the radiation beam for a Cobalt Teletherapy unit. The intercomparasion with the Baldwin-Farmer unit presented a maximum variation of 3%. (author) [pt

  7. New DRIE-Patterned Electrets for Vibration Energy Harvesting

    Directory of Open Access Journals (Sweden)

    Chaillout J.-J.

    2012-10-01

    Full Text Available This paper is about a new manufacturing process aimed at developing stable SiO2/Si3N4 patterned electrets using a Deep Reactive Ion Etching (DRIE step for an application in electret-based Vibration Energy Harvesters (e-VEH. This process consists in forming continuous layers of SiO2/Si3N4 electrets in order to limit surface conduction phenomena and is a new way to see the problem of electret patterning. Experimental results prove that patterned electrets charged by a positive corona discharge show excellent stability with high surface charge densities that may reach 5mC/m2 on 1.1μm-thick layers, even with fine patterning and harsh temperature conditions (up to 250°C. This paves the way to new e-VEH designs and manufacturing processes.

  8. Inorganic electret with enhanced charge stability for energy harvesting

    DEFF Research Database (Denmark)

    Wang, Fei; Hansen, Ole

    2013-01-01

    We report a new surface treatment of inorganic electret materials which enhances the charge stability. Coating the surfaces with 1H, 1H, 2H, 2H - perfluorodecyltrichlorosilane (FDTS) makes the electret surface more hydrophobic which improves the surface charge stability under high humidity condit...... conditions. Thermal tests show that the thermal stability of charge in the inorganic electrets is also much better than that of polymer materials such as CYTOP. A demonstrator device with SiO2 electrets shows promising results for energy harvesting applications....

  9. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of electret dosemeter to slow neutrons exposure is cited, mentioning the preparation and the irradiation of dosemeter with Am-Be source. Some theory considerations about the response of electret dosemeter to slow and fast neutrons are also presented. (C.G.C.) [pt

  10. Influence of porous PTFE/LDPE/PP composite electret in skin ultrastructure

    International Nuclear Information System (INIS)

    Jiang, J; Liang, Y Y; Tang, Y; Ye, X T; Yang, Y J; Song, M H; Cui, L L; Hou, X M

    2008-01-01

    Corona charging and heat melting method were used to prepare porous PTFE electret and porous PTFE/LDPE/PP composite electret, respectively. After 0.5, 1, 1.5, 3 and 4 hour's action of fluorescein sodium (FINa) and -300V porous PTFE/LDPE/PP composite electret on the excised abdominal skin of rat, the skin structure was studied by means of scanning electron microscopy, transmission electron microscopy and confocal laser scanning microscopy, respectively, to probe the mechanism of electret on transdermal drug delivery. The results indicated that negative electret could increase the transdermal delivery of FINa due to its effect on changing the organized structure of stratum corneum, enlarging the hair follicles, which may be the mechanism of electret in enhancing transdermal drug delivery.

  11. Study on the electrostatic and piezoelectric properties of positive polypropylene electret cyclosporine A patch

    International Nuclear Information System (INIS)

    Guo, X; Liang, Y Y; Jiang, J; Liu, H Y; Cui, L L

    2013-01-01

    Corona charged electrets at voltages of +500 V, +1000 V and +1500 V were prepared for manufacturing polypropylene (PP) electret blank patches and PP electret drug patches. The stability of external electrostatic field of the electret patch and the polarization of the drug in patch under the internal electrostatic field of the electret were studied. The results indicate that all the electret drug patches had good charge storage stabilities. However, the non-electrode coated electret drug patch had better stability in the external electrostatic field than that of the electrode coated electret drug patch. The higher the charging voltage of the electret, the faster the surface potential of the electret drug patch decayed, and the worse the stability of the external electrostatic field. All the electrets used in this study could result in the polarization of the model drug in patch. The piezoelectric properties of non-electrode coated electret drug patch increased with the charging voltage of the electret. However, excessively higher charging voltage could result in the decreased polarization of the drug in patch. Both the stability of the external electrostatic field of electret and the polarization of drug were the key factors for controlled drug release and skin permeation.

  12. A new electret dosimeter for fast neutrons

    International Nuclear Information System (INIS)

    Campos, L.L.; Suarez, A.A.; Mascarenhas, S.

    1982-01-01

    A new electret for fast-neutron personnel dosimetry is described and calibration curves obtained. Its performance may be improved by changes in the wall composition and geometric parameters. The advantages of electrets over TL and film are the non-erasure of information, low cost, fast reading and portability. (U.K.)

  13. Characterization of Electret Based on Inorganic-organic Nanocomposite Using Fluoropolymer and Silica Nanoparticles

    International Nuclear Information System (INIS)

    Suzuki, M; Shimokizaki, M; Takahashi, T; Aoyagi, S; Yoshikawa, Y

    2015-01-01

    An A novel electret based on inorganic-organic nano composite using fluoropolymer and silica nanoparticles was developed in this study. CYTOP® is used to fabricate the nanocomposite electret, which is one of fluoropolymer. Three kinds of silica nanoparticles dispersed in methyl ethyl ketone were employed. Each type of nanoparticles was mixed in the CYTOP or stuck between three layers of CYTOP. Then, negative charge was implanted by corona discharge method. The initial surface potential of the nanocomposite electret was higher than that of a control electret made of pure CYTOP. Additionally, time stability of those was also better than that of control electret. However, above mentioned properties of the mix-typed electret was worse than that of stuck-typed electret, because of discharging through aggregates composed of the nanoparticles. (paper)

  14. Comparative enhancing effects of electret with chemical enhancers on transdermal delivery of meloxicam in vitro

    International Nuclear Information System (INIS)

    Cui, L L; Hou, X M; Li, G D; Jiang, J; Liang, Y Y; Xin, X

    2008-01-01

    Electret offers enhancing effect in transdermal drug delivery for altering of the arrangement of lipid molecules in the stratum corneum, forming many transient permeable apertures and enhancing the transdermal drug delivery. In this paper, meloxicam patch formulations were developed to make the comparative study of transdermal drug delivery between electret and chemical enhancers. Patches were made into control, electret, chemical enhancer and electret with chemical enhancer ones, according to the preparation procedure. The electret combined with chemical enhancer patch was designed to probe the incorporation between electret and chemical enhancer in transdermal drug delivery. The meloxicam release from the patch was found to increase in order of blank, chemical enhancer, electret and electret with chemical enhancer patch, in general.

  15. Semiconductor-based electret sensors for sound and pressure

    NARCIS (Netherlands)

    Voorthuyzen, J.A.; Bergveld, Piet; Sprenkels, A.J.

    1989-01-01

    The theory and experimental results for integrated electret-based silicon sensors for the detection of sound and pressure are presented. A silicon electret microphone for use in hearing-aids is described. It has an experimentally determined sensitivity of 19 mV/Pa in the frequency range of 50 Hz to

  16. Charge distribution and stability in electret materials

    DEFF Research Database (Denmark)

    Thyssen, Anders

    The objective of the work presented in this Ph.D. thesis is to give a broader understanding of which key parameters influence the charge stability of polymer electrets, and how the electrical charges are distributed. This has been achieved using polypropylene as an electret polymer model system......-PP and i-PP, is because the charge retention is extremely sensitive to the sample preparation. This was seen in regard to the thermal history of the samples and the influence of micron and nano size particles in the polymer electret. Through adding micron and nano size calcium carbonate and aluminium oxide....... By means of kinetic rate theory the discharge behaviour could be explained for polypropylene when thermally stimulated. This resulted in the determination of several activation energies, which could be used for describing the discharging seen at isothermal conditions. This theory is a powerful tool...

  17. Physical aspects of electron emission spectra shape for ferroelectrics-electrets

    International Nuclear Information System (INIS)

    Kolesnikov, V.V.; Kozakov, A.T.

    2002-01-01

    One introduces a theoretical approach establishing a link between the peculiarities of spectrum of electron emission from ferroelectrics-electrets and the behavior of potential at a specimen surface. From these points of view one analyzes physical nature of the key peculiarities in the experimental spectra. One points out strong effect of electret charge relaxation on their shape due to bifurcation (branching) of peculiarities in a spectrum. A complex shape of spectrum of electron emission from ferroelectrics-electrets results from peculiarities of distribution of electrical field and polarization along their surface [ru

  18. Electret dosimeter utilizing gas multiplication

    International Nuclear Information System (INIS)

    Ikeya, M.; Miki, T.

    1980-01-01

    It was found that the high electric field around the surface of an electret leads to cascade multiplication of the ionization process in a surrounding gas. Very sensitive charge decay constants of the order of 1mrad, were obtained for electrets composed of polyvinyliden fluoride or teflon polymers. The reduced charge is stable and can be utilized in personnel dosimetry. A simple pocket chamber dosimeter is described consisting of a small speaker or buzzer, a cylindrical chamber filled with air, argon or other gases, a polymer thermoelectret foil and an electrode. The sonic vibration of the foil induces an alternating charge on the electrode which is amplified and detected. The feasibility of this dosimeter and its shock and vibration resistance have been demonstrated. (author)

  19. Electret filter collects more exhaled albumin than glass condenser

    Science.gov (United States)

    Jia, Ziru; Liu, Hongying; Li, Wang; Xie, Dandan; Cheng, Ke; Pi, Xitian

    2018-01-01

    Abstract In recent years, noninvasive diagnosis based on biomarkers in exhaled breath has been extensively studied. The procedure of biomarker collection is a key step. However, the traditional condenser method has low efficacy in collecting nonvolatile compounds especially the protein biomarkers in breath. To solve this deficiency, here we propose an electret filter method. Exhaled breath of 6 volunteers was collected with a glass condenser and an electret filter. The amount of albumin was analyzed. Furthermore, the difference of exhaled albumin between smokers and nonsmokers was evaluated. The electret filter method collected more albumin than the glass condenser method at the same breath volume level (P albumin than nonsmokers were also observed (P albumin than nonsmokers. PMID:29384875

  20. Development of electret technology to measure indoor radon-daughter concentrations: Final report (Phase 1)

    International Nuclear Information System (INIS)

    Kotrappa, P.; Dempsey, J.C.; Stieff, L.R.

    1989-05-01

    A new type of radon progeny monitor called an electret radon progeny integrating sampling unit (E-RPISU) was developed and demonstrated which uses an electret ion chamber to measure the progeny concentration. A conventional 1 LPM particulate air sampling system is used to collect the progeny on a 35 cm 2 filter which is mounted on the side of the electret ion chamber such that the collected progeny are exposed to the inside of the chamber. The alpha radiation emitted by the progeny collected on the filter ionizes the air in the 220 ml chamber. The ions of opposite polarity collect on the surface of the 127 μm thick electret and reduce its surface voltage. A specially built surface voltmeter is used to measure the electret voltage before and after sampling. The electret voltage drop which occurs during the sampling period is shown to be proportional to the time integrated progeny concentration. Two prototype systems were fabricated and tested in homes and in calibrated radon chambers. The resulting data are presented and analyzed. The calibration factor for the E-RPISU ranged from 1.5 to 2.0 V/mWL-day depending on the electret voltage. Two of the E-RPISUs were delivered to UNC Geotech for further testing. 32 refs., 11 figs., 5 tabs

  1. Modeling and characterization of electret based vibration energy harvesters in slot-effect configuration

    International Nuclear Information System (INIS)

    Renaud, M; Altena, G; Elfrink, R; Goedbloed, M; De Nooijer, C; Van Schaijk, R

    2015-01-01

    The purpose of this article is to elaborate a model and the optimization guidelines for electret based harvesters with a specific electret/electrodes configuration, namely the slot-effect configuration. Slot-effect configured harvesters have been investigated experimentally by several research groups. A model describing their dynamic behavior has also been recently proposed in the literature. However, the simplifications used in the existing model can lead to inaccuracies and a refined analysis is elaborated in the present article. The model is compared with experimental measurements on MEMS fabricated devices with a corrugated electret. The electrodes dimensioning in the MEMS device are chosen so that the harvester behaves in a quasi-linear manner over its full range of displacement. This quasi-linearity simplifies greatly the device optimization. Indeed, the behavior of the developed electrostatic harvester is shown to be very comparable to that of piezoelectric harvesters, which are very well understood and documented. The influence of several design parameters on output power performance is investigated. As long as pull-in and breakdown voltage effects can be avoided, the electret surface potential should be maximized and the air gap minimized. We also investigate theoretically the influence of three types of electret on the generated power: planar, corrugated with partial charge coverage, and corrugated with full charge coverage. With the dimensions corresponding to our MEMS devices, the output power characteristics for the three types of electret are similar. However, it is shown that this is not always true. In some conditions, corrugated electrets with full charge coverage are detrimental for the generated power. (paper)

  2. Lithium tri borate (LiB3O5) embedded polymer electret for mechanical sensing application

    Science.gov (United States)

    Murugan, S.; Praveen, E.; Prasad, M. V. N.; Jayakumar, K.

    2017-05-01

    Lithium tri borate (LiB3O5) particles were synthesized by precipitation assisted high temperature solid state reaction. The particles were embedded in chitosan polymer and used as an electret. This electret was characterized for the suitability as a sensing element in vibration accelerometer. It is observed that LiB3O5 embedded electret exhibiting piezoelectric property. The electret is also giving an isolation of > 999 MΩ at 100 Vdc, 250 Vdc, 500 Vdc and 1kVdc confirms compatible for intrinsically safe sensing alternative in vibration accelerometer.

  3. Evaluation of Electrostatic Force on Bipolar Charged Electret

    International Nuclear Information System (INIS)

    Sonoda, K; Minami, K; Miwatani, N; Fujita, T; Kanda, K; Maenaka, K

    2014-01-01

    This paper presents an evaluation of an electrostatic vibration energy harvester with the bipolar charged electret. The energy harvester with the size of 13 × 12 × 1.2 mm 3 was fabricated. The output power of the bipolar charged with ±250 V harvester was 9 μW when the acceleration was 1.4 g at 352 Hz with 0.9 MΩ load resistance. The effectiveness against the velocity-damped resonant-generator (VDRG) limit was 2.5%. The electrostatic forces of the actual device with DC bias, which simulates charged electret with monopolar and bipolar were experimentally and numerically verified. We estimated the electrostatic force by measuring the vibration amplitude versus applied acceleration of the electret mass. As a result, we investigated the bipolar charged device can reduce the effect of electrostatic force as low as no bias condition. The numerical model of the energy harvester considering the electrostatic force by FEM static analysis was also established. The comparison between the numerical model and the measurement results showed a similar inclination

  4. Properties of electret ionization chambers for routine dosimetry in photon radiation fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.

    1985-01-01

    The main properties of photon routine dosemeters are their energy and angular dependence as well as their measuring range and accuracy. The determination of radiation exposure from dosemeter response is based on the choice of an appropriate conversion factor taking into account the influence of body backscattering on the dosemeter response. Measuring range and accuracy of an electret ionization chamber first of all depend on electret stability, methods of charge measurement, and geometry of the chamber. The dosemeter performance is described for an electret ionization chamber which was designed for application to routine monitoring of radiation workers. (author)

  5. Properties of an electret ionisation chamber for individual dosimetry in photon radiation fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.

    1985-01-01

    The main properties of individual photon dosemeters are their energy and angular dependence and their measuring range and measurement accuracy. The determination of radiation exposure from the dosemeter readout is based on the choice of appropriate conversion factors, taking into account the influence of body backscatter on the dosemeter readout. The measurement range and accuracy of an electret ionisation chamber primarily depend on the electret stability and charge state measurement as well as on the chamber geometry. Dosimetric properties are described for an electret ionisation chamber designed for personnel monitoring. (author)

  6. Electret dosemeter for beta radiation

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    The response characteristics of an electret dosemeter for beta radiation are studied. Experiments were performed using different geometries and walls, and it was verified for which geometry the dosemeter sensitivity is greater. Sources of 90 Sr - 90 Y, 204 Tl and 85 Kr were used in the experiments. (I.C.R.) [pt

  7. Promotion of the transdermal delivery of protein drugs by N-trimethyl chitosan nanoparticles combined with polypropylene electret.

    Science.gov (United States)

    Tu, Ye; Wang, Xinxia; Lu, Ying; Zhang, He; Yu, Yuan; Chen, Yan; Liu, Junjie; Sun, Zhiguo; Cui, Lili; Gao, Jing; Zhong, Yanqiang

    We recently reported that electret, which was prepared by a corona charging system with polypropylene film, could enhance the transdermal delivery of several drugs of low molecular weight. The aim of this study was to investigate whether electret could enhance the transdermal delivery of protein drugs by N -trimethyl chitosan nanoparticles (TMC NPs) prepared by an ionic gelation method. A series of experiments were performed, including in vitro skin permeation assays and anti-inflammatory effects, to evaluate the transdermal delivery of protein drugs by TMC NPs in the presence of electret. The results showed that in the presence of electret, the transdermal delivery of protein drugs in TMC NPs was significantly enhanced, as demonstrated by in vitro permeation studies and confocal laser scanning microscopy. Notably, superoxide dismutase-loaded TMC NPs combined with electret exhibited the best inhibitory effect on the edema of the mouse ear. TMC NPs combined with electret represent a novel platform for the transdermal delivery of protein drugs.

  8. Inhibition effects of a negative electret 5-FU patch on the growth of a hypertrophic scar

    Science.gov (United States)

    Wang, YUAN; Lili, XU; Ping, HUANG; Xiaoqiang, AN; Lili, CUI; Jian, JIANG

    2018-05-01

    In this study, the hypertrophic scar (HS) model in rats was established. 5-fluorouracil (5-FU) patch, ‑1000 V and ‑2000 V polypropylene (PP) electret 5-FU patches were prepared and applied onto the wound. The in vitro permeation experiment was performed using the Franz diffusion cell system to determine the permeation cumulative amount and retention amount of 5-FU through/in scar skin. The inhibition effect of negative electret on growth of HS was studied by hematoxylin-eosin (HE) staining, Masson staining and the immunohistologicall methods. The permeation study indicated that a negative electret could enhance the permeation and retention of 5-FU through and in scar skin respectively. HE staining and Masson staining indicated a better effect for ‑1000 V and ‑2000 V electret 5-FU patches on HS inhibition after 28 d post-wounding compared with 5-FU patch. The immunohistological study showed much more reduced expressions of collegan type I, collegan type III, TGF-β1 and HSP47 in scar tissue after application of negative electret 5-FU patches than those of 5-FU patch. A negative electret 5-FU patch may be advantageous for HS treatment.

  9. Ferroelectric Dipole Electrets Prepared from Soft and Hard PZT Ceramics in Electrostatic Vibration Energy Harvesters

    International Nuclear Information System (INIS)

    Asanuma, H; Oguchi, H; Hara, M; Kuwano, H

    2013-01-01

    Aiming at longer stability of surface potential, we propose a ferroelectric dipole electret (FDE) prepared from hard ferroelectric material. We compared output power of electrostatic vibration energy harvester and surface potential stability between FDEs prepared from soft and hard PZT ceramics, as well as a CYTOP polymer electret. The hard FDE showed a seven-fold increase in output power over the soft FDE and nine-fold increase over the CYTOP polymer electret. The hard FDE also showed longer stability of surface potential than that of the soft FDE, whereas the stability of the hard FDE was not yet comparable to that of CYTOP polymer electret. A FDE prepared from harder PZT ceramic (with higher coercive electric field and Curie temperature) may provide more stability in surface potential

  10. Radon monitoring technique with electret collecting

    International Nuclear Information System (INIS)

    Tian Zhiheng; Zuo Fuqi; Xiao Detao; Zhao Xkiuliang

    1991-12-01

    The integrating radon monitoring technique with electret collecting is a method which collects the 218 Po + positive ions by electrostatic field produced by electret. It has greatly improved the sensitivity of radon measurement. The response factor of this method reaches to 4.7 cm -2 Bq -1 m 3 h -1 , 1000 times larger than that of common passive sampling method. The monitoring device and its principle are introduced. The measuring results of radon concentration and radon flux rate and quality assurance system by using this method in the Qinshan Nuclear Power Plant, Human Environmental Monitoring Central Station and some uranium mines are also presented. The analytical results show that the radon concentration in the Qinshan Nuclear Power Plant is affected by wind direction. When wind directs toward sea, the radon concentration is high. If the wind is to the contrary, it is low. The radon concentration ratio of both is about 2

  11. Micro-fabricated Liquid Encapsulated Energy Harvester with Polymer Barrier Layer as Liquid Electret Interface

    International Nuclear Information System (INIS)

    Bu, L; Xu, H Y; Xu, B J; Song, L

    2014-01-01

    This paper addresses the electret discharge issue for liquid based electret energy harvesters. An interface structure of PDMS/PTFE polymer barrier layer between liquid and electrets is introduced, achieving 75% charge retain rate over 100h, compared with 0% without the proposed layer over 100h. Further, the PDMS/PTFE layer is introduced into liquid encapsulated energy harvester (LEEH) and is compatible with micro-fabrication process. The retain rate of device voltage is about 47%∼65% over 100h. At 100h after corona charging, the device generates maximally 3.7V, 0.55μW @1Hz rotation

  12. Response of electret dosemeter to slow neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.; Pela, C.A.; Zimmerman, R.L.

    1987-01-01

    The response of the electret dosemeter to exposition of slow neutrons is studied. Different external coatings are used on the dosemeter (polyethylene, alminium, polyethylene + boron, aluminium + boron) and exposure curves (with and without water) are compared. (M.A.C.) [pt

  13. Fluorinated cellular polypropylene films with time-invariant excellent surface electret properties by post-treatments

    International Nuclear Information System (INIS)

    An Zhenlian; Mao Mingjun; Yao Junlan; Zhang Yewen; Xia Zhongfu

    2010-01-01

    In this work, to improve the electret properties of cellular polypropylene films, they were fluorinated and post-treated with nitrous oxide and by isothermal crystallization. Surface electret properties of the samples were investigated by thermally stimulated discharge current measurements, and their compositions and structures were analysed by attenuated total reflection infrared spectroscopy and wide angle x-ray diffraction, respectively. Time-dependent deterioration of surface electret properties was observed for the fluorinated samples without the nitrous oxide post-treatment. However, deterioration did not occur for the fluorinated samples post-treated with nitrous oxide, and time-invariant excellent surface electret properties or deep surface charge traps were obtained by the combined post-treatments of the fluorinated samples with nitrous oxide and by isothermal crystallization. Based on the analyses of composition and structure of the treated samples, the deterioration was clarified to be due to a trace of oxygen in the reactive mixture, which led to the formation of peroxy RO 2 . radicals in the fluorinated surface layer. The time invariability of surface electret properties was owing to the rapid termination of the peroxy RO 2 . radicals by nitrous oxide. And the deep surface charge traps resulted from the isothermal crystallization treatment which led to an increase in the efficient charging interface between the crystallite and amorphous region and its property change.

  14. Growth and decay of surface charges in grafts of Teflon in electrets states

    International Nuclear Information System (INIS)

    Spinelli, I.M.M.

    1971-01-01

    The greatest problem founded in a cardiovascular implant is the thrombus formation. Teflon grafts were used in electret state for prothesis in vena cava of dogs. To put these grafts in an electret state a corona discharge in air was used and homocharge was formed predominantly. To measure the formed surface charge the oscillating capacitor technique was used. In the electret state the grafts have showed an initial density of charge of 10- 8 C/cm 2 and the charge decay and time decay of the samples were measured under many conditions. We found two activation energies, E 2 =0.17 e V and E 3 =1.12 e V, due to rapid and slow decay, respectively. The charged grafts were sterilized with ethilene gas oxide and this process apparently did not influence the charges

  15. Electret Stability Related to the Crystallinity in Polypropylene

    DEFF Research Database (Denmark)

    Thyssen, Anders; Almdal, Kristoffer; Thomsen, Erik Vilain

    2017-01-01

    preparation processes and characteristics can be identical. This is important since the performance of an electret material is sensitive to its previous process history. Activation energies used for predicting the thermal potential decay are determined from thermally stimulated current and isothermal...

  16. Flexible electret energy harvesters with parylene electret on PDMS substrates

    International Nuclear Information System (INIS)

    Chiu, Yi; Wu, Shih-Hsien

    2013-01-01

    Currently, most vibrational energy harvesters have rigid and resonant structures to harvest energy from periodic motions in specific directions. However, in some situations the motion is random and aperiodic; or the targeted energy source is the strain energy in deformation, rather than the kinetic energy in vibration. Therefore we propose and demonstrate a PDMS-based flexible energy harvester with parylene-C electret that can be attached to any deformable surfaces to harvest the stain energy caused by external deformation. The proposed flexible harvester was fabricated and characterized. The measured power at 20 Hz is 0.18 μW and 82 nW in the compression and bending modes, respectively. Such a harvester has the potential for wearable and implantable electronics applications

  17. A Program for Follow-Up and Quality Assurance of Electret Results

    International Nuclear Information System (INIS)

    Sarusi, B.; Levinson, S.; Lavi, N.; German, U.

    2014-01-01

    The most important naturally occurring radio-nuclides in the environment are 40K and 238U and 232Th, which are heads of decay series. Building materials may also contain enhanced levels of naturally occurring radioisotopes which may be sources of external and internal radiation exposure in dwellings. The external exposure is due to the direct radiation from the radioisotopes in the decay series of 238U and 232Th, and among these daughters, two Radon isotopes are produced: 222Rn is a daughter in the chain of decay of 238U and 220Rn is a daughter in the 232Th chain. Radon is a gas, it undergoes diffusion in the building material and exhalation to the surrounding. Besides, radon is emanated also from soil and its concentration can be significant in radon prone areas. Inhalation of air with increased level of Radon causes internal exposure, which is the greatest contribution to the exposure of individuals to natural radiation. Therefore, accurate measurement of radon concentration is of great importance. There are several methods to determine the radon concentration in air. The Israeli regulation for measuring the radioactive content in building materials specifies three methods for radon concentration measurements: applying continuous monitoring, using Electrets and using active charcoal cassettes. Using Electrets is convenient, as a relatively simple stand-alone system can be used. The follow-up and quality assurance of Electrets results is the subject of the present work. For this purpose a computer program was developed which handles the Electrets results database and applies various tools for analysis

  18. Study of charge reader probes for electret dosemeters; Estudo de sondas leitoras de carga para dosimetros de eletretos

    Energy Technology Data Exchange (ETDEWEB)

    Parada, Marco A.; Silva, Nivaldo C. da; Almeida, Adelaide de [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica e Matematica

    2001-07-01

    Electrets are insulating materials with a quasi-permanent polarization. It can be made from carnauba wax, Teflon and other materials for several applications as transducers, electrophotography, high efficiency air filters and as radiation dosimeters. Electret dosemeters may be used for {alpha}, {beta}, {gamma}, X, e{sup -} and neutrons radiations with a low construction cost and a simple associated instrumentation. The probe, for charge measurements of the electret dosimeters, is an important device in the experimental set up and its geometry varies according to the geometry of the dosimeter or the scope of the measurements. In this work the development of several probes is described (cylindrical, 1/3 cylindrical and three points probes with different sizes). From the measurements one can demonstrate that cylindrical probe may be used for cylindrical electret geometry, 1/3 cylindrical probe for measurements of directional dependence of the dose and point probe for scanning measurements of plane areas. For high resolution, small point probe may be used and for high sensitivity, the probe-electret distance must be minimized taking account of the Paschen discharge. (author)

  19. Electret ionization chamber: a new method for detection and dosimetry of thermal neutrons

    International Nuclear Information System (INIS)

    Ghilardi, A.J.P.

    1988-01-01

    An electret ionization chamber with boron coated walls is presented as a new method for detecting thermal neutrons. The efficiency of electret ionization chambers with different wall materials for the external electrode was inferred from the results. Detection of slow neutrons with discrimination against the detection of γ-rays and energetic neutrons was shown to depend on the selection of these materials. The charge stability over a long period of time and the charge decay owing to natural radiation were also studied. Numerical analysis was developed by the use of a micro-computer PC-XT. Both the experimental and numerical results show that the sensitivity of the electret ionization chamber for detection of thermal neutrons is comparable with that of the BF 3 ionization chamber and that new technologies for deposition of the boron layer will produce higher efficiency detectors. (author). 102 refs, 32 fig, 10 tabs

  20. Characterizing opto-electret based paper speakers by using a real-time projection Moiré metrology system

    Science.gov (United States)

    Chang, Ya-Ling; Hsu, Kuan-Yu; Lee, Chih-Kung

    2016-03-01

    Advancement of distributed piezo-electret sensors and actuators facilitates various smart systems development, which include paper speakers, opto-piezo/electret bio-chips, etc. The array-based loudspeaker system possess several advantages over conventional coil speakers, such as light-weightness, flexibility, low power consumption, directivity, etc. With the understanding that the performance of the large-area piezo-electret loudspeakers or even the microfluidic biochip transport behavior could be tailored by changing their dynamic behaviors, a full-field real-time high-resolution non-contact metrology system was developed. In this paper, influence of the resonance modes and the transient vibrations of an arraybased loudspeaker system on the acoustic effect were measured by using a real-time projection moiré metrology system and microphones. To make the paper speaker even more versatile, we combine the photosensitive material TiOPc into the original electret loudspeaker. The vibration of this newly developed opto-electret loudspeaker could be manipulated by illuminating different light-intensity patterns. Trying to facilitate the tailoring process of the opto-electret loudspeaker, projection moiré was adopted to measure its vibration. By recording the projected fringes which are modulated by the contours of the testing sample, the phase unwrapping algorithm can give us a continuous phase distribution which is proportional to the object height variations. With the aid of the projection moiré metrology system, the vibrations associated with each distinctive light pattern could be characterized. Therefore, we expect that the overall acoustic performance could be improved by finding the suitable illuminating patterns. In this manuscript, the system performance of the projection moiré and the optoelectret paper speakers were cross-examined and verified by the experimental results obtained.

  1. Enhancing effect of negative polypropylene electret on in vitro transdermal delivery of cyclosporine A solution and its synergistic effect with ethyl oleate

    International Nuclear Information System (INIS)

    Cui, L L; Liu, H Y; Ma, L; Liang, Y Y; Guo, X; Jiang, J

    2013-01-01

    In this study, the corona charged electrets at voltages of −500 V, −1000 V and −2000 V were made from polypropylene (PP) film. The cyclosporine A (CsA) and 10% ethyl oleate were chosen as the model drug and chemical enhancer, respectively. The charge storage stability of the electrets and the in vitro transdermal behaviour of the model drug in solution under different conditions were studied. The results indicate that the external electrostatic field of the negative PP electrets could penetrate through the rat skin and enhance the transdermal delivery of cyclosporine A. A synergistic effect on enhancing the transdermal delivery of cyclosporine A was observed by combining different surface potential negative PP electrets with 10% ethyl oleate, and the amount of transdermal delivery of CsA was greatly increased comparing with only application of electrets. Therefore, the combination application of electret and chemical enhancer could be a feasible strategy in enhancing transdermal delivery of small peptide drugs or some large molecular drugs.

  2. Light Dependent Resistance as a Sensor in Spectroscopy Setups Using Pulsed Light and Compared with Electret Microphones

    Directory of Open Access Journals (Sweden)

    Daniel Acosta-Avalos

    2006-05-01

    Full Text Available Light-dependent resistances (LDR are cheap light sensors. A less known lightdetector is the electret microphone, whose electret membrane functions as a perfectabsorber, but only detects pulsed light. The aim of this study was to analyze the use of aLDR and an electret microphone as a light sensor in an optical spectroscopy system usingpulsed light. A photoacoustic spectroscopy setup was used, substituting the photoacousticchamber by the light sensor proposed. The absorption spectra of two different liquids wereanalyzed. The results obtained allow the recommendation of the LDR as the first choice inthe construction of cheap homemade pulsed light spectroscopy systems.

  3. A MEMS electret generator with electrostatic levitation for vibration-driven energy-harvesting applications

    International Nuclear Information System (INIS)

    Suzuki, Yuji; Miki, Daigo; Edamoto, Masato; Honzumi, Makoto

    2010-01-01

    In this paper, we propose a passive gap-spacing control method in order to avoid stiction between top and bottom structures in in-plane sensor/actuator/generator applications. A patterned electret using a high-performance perfluoro polymer material is employed to induce a repulsive electrostatic force. An out-of-plane repulsive force is successfully demonstrated with our early prototype, in both air and liquid. By using the present electret-based levitation method to keep the air gap, a MEMS electret generator has been developed for energy-harvesting applications. A dual-phase electrode arrangement is adopted in order to reduce the horizontal electrostatic damping force. With the present prototype, about 0.5 µW is obtained for both phases of the generator, resulting in a total power output of 1.0 µW at an acceleration of 2 g with 63 Hz. With our electromechanical model of the generator, we have confirmed that the model can mimic the response of the generator prototype

  4. Mechanism of piezo - and pyroelectricity of poly (vinylidene fluoride) electret

    International Nuclear Information System (INIS)

    Wada, Y.

    1980-01-01

    Basic concepts of the piezo - and pyroelectricity theory of polymer electrets are given. The origins of these effects are presented. The piezo - and pyroelectric constants are numerically obtained. (L.C.) [pt

  5. Thickness effects of electret and polymer for energy harvesting: Case of CYTOP- CTLM and polyurethane

    Science.gov (United States)

    Belhora, Fouad; Guyomar, Daniel; Mazroui, M'Hammed; Hajjaji, Abdelowahed; Boughaleb, Yahia

    2015-02-01

    The authors aimed to investigate the electrostrictive polymers for energy harvesting. These particular materials have demonstrated a great ability to convert mechanical energy into electrical energy and vice versa. This energy conversion has been exploited in an extensive range of applications, including sensors and actuators. On the other hand, the reason for using electrets in the present work was to produce the static electric field required to capture energy through electrostrictive polymers and hence to avoid the problem of high voltage power. For a good μ-generators performance the electromechanical parameters have to be optimized. Experimental results show the possibility of improving harvesting energy without power supply, by using hybridization of electrets and electrostrictive materials, which is very promising for future applications. Moreover, in order to obtain a maximum of harvested power one should choose a minimum of the thickness of the electrets and a maximum of thickness of polymer. The measured results are analyzed and compared with the theoretical model and they are consistent. These results shed light on the hybridization of electrostrictive polymer with electrets, and are useful for improving the harvesting energy.

  6. Suspended polytetrafluoroethylene nanostructure electret film in dual variable cavities for self-powered micro-shock sensing

    Science.gov (United States)

    Zhu, Jianxiong; Chen, Cong; Guo, Xiaoyu

    2018-04-01

    We report a suspended polytetrafluoroethylene (PTFE) nanostructure electret film in dual variable cavities for a self-powered micro-shock sensing application. The prototype contained series variable air cavities, a suspended nanostructure PTFE electret film and independent electrode films. The charges on the suspended nanostructure PTFE electret film provided the electrostatic field around the electret film in the series variable air cavities. When the reported device was driven by a micro-shock pressure, the inducted electrostatic charges on both the top and bottom electrodes would vary as the micro-shock pressing or releasing. Experimental results showed that the maximum of a short-circuit current density (J sc ) and an open-circuit voltage (V oc ) reached 3 ± 0.1 nA cm‑2 and 3.6 ± 0.1 V, respectively. It was found that the parameter J sc was more advantageous in identifying stronger shocks (parameter acceleration a bigger than 0.1 m s‑2), whereas the parameter V oc was more sensitive for weaker shocks, such as acceleration a smaller than 0.1 m s‑2. Moreover, finger continuous micro-shock pressure taps application was used to demonstrate the mechanical energy conversion performance with 4.5 ± 0.2 V open-circuit voltages. The research on the nanostructure electret PTFE film in series dual variable air cavities not only gave us a fresh idea about the principle and design of the shocking sensor, but also provided an easy fabrication and a low cost shocking sensor for the Internet of Things (IoT) systems.

  7. Continuous measurement of the radon concentration in water using electret ion chamber method

    International Nuclear Information System (INIS)

    Dua, S.K.; Hopke, P.K.

    1992-10-01

    A radon concentration of 300 pCi/L has been proposed by the US Environmental Protection Agency as a limit for radon dissolved in municipal drinking water supplies. There is therefore a need for a continuous monitor to insure that the daily average concentration does not exceed this limit. In order to calibrate the system, varying concentrations of radon in water have been generated by bubbling radon laden air through a dynamic flowthrough water system. The value of steady state concentration of radon in water from this system depends on the concentration of radon in air, the air bubbling rate, and the water flow rate. The measurement system has been designed and tested using a 1 L volume electret ion chamber to determine the radon in water. In this dynamic method, water flows directly through the electret ion chamber. Radon is released to the air and measured with the electret. A flow of air is maintained through the chamber to prevent the build-up of high radon concentrations and too rapid discharge of the electret. It was found that the system worked well when the air flow was induced by the application of suction. The concentration in the water was calculated from the measured concentration in air and water and air flow rates. Preliminary results suggest that the method has sufficient sensitivity to measure concentrations of radon in water with acceptable accuracy and precision

  8. The effects of magnetic fields on carnauba wax electret formation

    Science.gov (United States)

    Clator, Irvin G.

    1987-08-01

    The results of thermally stimulated depolarization current and effective surface charge-density measurements indicate that magnetic fields do not produce carnauba wax electrets and that previously reported data can be attributed to nonmagnetic effects.

  9. Collecting Protein Biomarkers in Breath Using Electret Filters: A Preliminary Method on New Technical Model and Human Study.

    Directory of Open Access Journals (Sweden)

    Wang Li

    Full Text Available Biomarkers in exhaled breath are useful for respiratory disease diagnosis in human volunteers. Conventional methods that collect non-volatile biomarkers, however, necessitate an extensive dilution and sanitation processes that lowers collection efficiencies and convenience of use. Electret filter emerged in recent decade to collect virus biomarkers in exhaled breath given its simplicity and effectiveness. To investigate the capability of electret filters to collect protein biomarkers, a model that consists of an atomizer that produces protein aerosol and an electret filter that collects albumin and carcinoembryonic antigen-a typical biomarker in lung cancer development- from the atomizer is developed. A device using electret filter as the collecting medium is designed to collect human albumin from exhaled breath of 6 volunteers. Comparison of the collecting ability between the electret filter method and other 2 reported methods is finally performed based on the amounts of albumin collected from human exhaled breath. In conclusion, a decreasing collection efficiency ranging from 17.6% to 2.3% for atomized albumin aerosol and 42% to 12.5% for atomized carcinoembryonic antigen particles is found; moreover, an optimum volume of sampling human exhaled breath ranging from 100 L to 200 L is also observed; finally, the self-designed collecting device shows a significantly better performance in collecting albumin from human exhaled breath than the exhaled breath condensate method (p0.05. In summary, electret filters are potential in collecting non-volatile biomarkers in human exhaled breath not only because it was simpler, cheaper and easier to use than traditional methods but also for its better collecting performance.

  10. Development of a High-performance Fluorpolymer Electret Mixed with Nano-particles and Its Application to Vibration Energy Harvesting

    International Nuclear Information System (INIS)

    Suzuki, M; Takahashi, T; Aoyagi, S

    2014-01-01

    We have been developing small power generation device of capacitance-type to be converted to electrical energy vibration energy using an electret. In this Study, dielectric nanoparticles were mixed with an electret made of fluorocarbon polymer. As a result, implanted charge density of the electret was successfully enhanced thanks to the mixing of particles. A small sized vibration energy harvester (VEH) was fabricated using the fluorocarbon mixed with dielectric nano-particles. As a result of applying vibration (20 Hz, 0.65 G) to the fabricated VEH, The maximum generated power of approximately 50 μW was obtained

  11. Comparison among the scintillation and electrets techniques for emission of alpha radiation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.; Gammage, R.B.

    2005-01-01

    A comparison of the scintillation and of electret techniques for measurement of Uranium, Plutonium and transuranic elements in low level radioactivity is presented in this work. The samples of material to measure were obtained by the Research Department of the Oak Ridge National Laboratory (ORNL) of contaminated soils by radioactive material of plutonium and other transuranic elements. The samples in both techniques were measured to infinite thickness. The electret E - PERM of Rad Elec. Inc.; it was the available selected detector in 1993 and the measures with this technique were carried out by the Dr. R. B. Gammage and the Dr. K. E. Meyer of the Health and Safety Research Division of ORNL. The scintillation technique for measurement of the samples up mentioned it was carried out by the Dr. Augusto Moreno y Moreno in the facilities of DOSAR of ORNL. The comparative results of the two techniques agree just as it is shown in this work; but the scintillation technique offers the advantage of a considerable reduction of the exposure time and reading of the samples - electret, if it is compared with the immediate measurement of the scintillation technique that is described in this work. (Author)

  12. New approach to improve the energy density of hybrid electret-dielectric elastomer generators

    Science.gov (United States)

    Lagomarsini, Clara; Jean-Mistral, Claire; Monfray, Stephane; Sylvestre, Alain

    2017-04-01

    Harvesting human kinetic energy to produce electricity is an attractive alternative to batteries for applications in wearable electronic devices and smart textile. Dielectric elastomers generators (DEGs) represent one of the most promising technologies for these applications. Nevertheless, one of the main disadvantages of these structures is the need of an external polarization source to perform the energetic cycle. In the present work, a hybrid electret-dielectric elastomer generator in DEG mode is presented. In this configuration, the electret material is used as polarization source of a classical DEG, i.e. an electrostatic generator based on electrical capacitance variation. The electrical energy output in this mode (1.06mJ.g-1) could be higher than the one obtained using a classical electret mode (0.55mJ.g-1), i.e. charges recombination. In this paper, the operation principle of the hybrid generator will be fully described and the design rules for the realization of the prototype will be presented. The experimental data obtained from the prototype will be compared to the results of FEM simulations.

  13. Patterned piezo-, pyro-, and ferroelectricity of poled polymer electrets

    International Nuclear Information System (INIS)

    Qiu, Xunlin

    2010-01-01

    Polymers with strong piezo-, pyro-, and ferroelectricity are attractive for a wide range of applications. In particular, semicrystalline ferroelectric polymers are suitable for a large variety of piezo- and pyroelectric transducers or sensors, while amorphous polymers containing chromophore molecules are particularly interesting for photonic devices. Recently, a new class of polymer materials has been added to this family: internally charged cellular space-charge polymer electrets (so-called “ferroelectrets”), whose piezoelectricity can be orders of magnitude higher than that of conventional ferroelectric polymers. Suitable patterning of these materials leads to improved or unusual macroscopic piezo-, pyro-, and ferroelectric or nonlinear optical properties that may be particularly useful for advanced transducer or waveguide applications. In the present paper, the piezo-, pyro-, and ferroelectricity of poled polymers is briefly introduced, an overview on the preparation of polymer electrets with patterned piezo-, pyro-, and ferroelectricity is provided and a survey of selected applications is presented.

  14. Proximity sensing of electrostatic induction electret nanoparticles device using separation electrode

    Directory of Open Access Journals (Sweden)

    Jianxiong Zhu

    2017-04-01

    Full Text Available We reported a two dimensional self-powered proximity sensor based on nanoparticles polytetrafluoroethylene (PTFE electrostatic induction electret using separation electrode. The structural pattern was carefully designed for identifying the specific position on the horizontal plane. When the separation electrode is motioned above the sensor, the induced charges on electrodes will change based on the coupling effect of the electret film. Experiment results showed that the proximity sensor works well with the velocity 0.05 m/s. We also found that the prototype have a good stability even with a huge uncontrolled perturbation on the Y direction. Our work could be a significant step forward in self-powered proximity sensing technology, with a wide range of potential applications in touchpad, robotics, and safety-monitoring device.

  15. Evaluations of dielectric property and drug release profile of 5-FU patches based on plasma charged electrets

    Science.gov (United States)

    Wang, YUAN; Hejuan, LIANG; Ping, HUANG; Xiaoqiang, AN; Jian, JIANG; Lili, CUI

    2018-05-01

    In the present study, the electret 5-fluorouracil patch was developed, the effective surface potential, piezoelectric coefficient d 33, open-circuit thermally stimulated discharge (TSD) current spectra and shear adhesion of the patch were measured. The drug release profile of the patch was determined by using high performance liquid chromatography method. A stable potential difference which was positively dependent on the surface potential of the electret was generated on two sides of the patch. The measurements of d 33 coefficient, TSD current spectra and adhesion performance showed that the electrostatic field of the electret could cause polarization and cohesive strength decreasing of the matrix molecules, change the distribution and interaction of the drug molecules in patch, therefore to increase the release of drug from the transdermal patch.

  16. Field trials of an electret based passive dust sampler in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M.A.; Brown, R.C.; Arthur, J. [Health and Safety Laboratory, Sheffield (United Kingdom)

    1997-12-31

    An electret-based passive dust sampler has been developed by the Health and Safety Laboratory, UK. The device consists of a small disc of electret (polymer holding a permanent electric charge) held between earthen plates, and it acts by attaching charged dust particles to itself. The device does not require a pump and its rate of sampling is independent of external air velocity, provided that the velocity exceeds a low limiting value. Experiments have been carried out in two coal mines. In each experiment two passive sampler were mounted alongside an MRE sampler at the statutory sampling point in the return roadway. Both passive samplers were mounted vertically but in one the plane of the electret was parallel to the air flow and in the other it was perpendicular. The result obtained from the first mine showed a good correlation between gravimetric estimates of dust concentration obtained with the passive samplers and respirable dust concentrations obtained with MRE. The correlation between the two sets of results at the second mine was not quite as good as those of the first, but was reasonable. In no instance was any significant difference observed between samples obtained from pairs of passive samples in different orientations. 8 refs., 5 figs., 2 tabs.

  17. Photo-electret effects in homogenous semiconductors

    International Nuclear Information System (INIS)

    Nabiev, G.A.

    2004-01-01

    In the given work is shown the opportunity and created the theory of photo-electret condition in semiconductors with Dember mechanism of photo-voltage generation. Photo-electret of such type can be created, instead of traditional and without an external field as a result of only one illumination. Polar factor, in this case, is the distinction of electrons and holes mobility. Considered the multilayered structure with homogeneous photoactive micro areas shared by the layers, which are interfering to alignment of carriers concentration. We consider, that the homogeneous photoactive areas contain deep levels of stick. Because of addition of elementary photo voltage in separate micro photo cells it is formed the abnormal-large photo voltage (APV-effect). Let's notice, that Dember photo-voltage in a separate micro photo-cell ≤kT/q. From the received expressions, in practically important, special case, when quasi- balance between valent zone and stick levels established in much more smaller time, than free hole lifetime, and we received, that photo-voltage is relaxing. Comparing of the received expressions with the laws of photo voltage attenuation in p-n- junction structures shows their identity; the difference is only in absolute meanings of photo voltage. During the illumination in the semiconductor are created the superfluous concentration of charge carriers and part from them stays at deep levels. At de-energizing light there is a gradual generation of carriers located at these levels

  18. A high-performance micro electret power generator based on microball bearings

    International Nuclear Information System (INIS)

    Yang, Zhaohui; Wang, Jing; Zhang, Jinwen

    2011-01-01

    In this paper, a high-performance micro electret power generator fabricated by simple bulk micromachining technology is presented. It has microballs as movable bearings for harvesting changing low-frequency vibration energy from the environment. The silicon V-grooves where the microballs slide have very smooth (1 1 1) planes, and so the device is sensitive to very slight vibration and almost has no resonant frequency. A plasma-enhanced chemical vapour deposition SiO 2 /Si 3 N 4 double layer was used as the electret. The device was fabricated by simple micromachining technology suitable for mass production except for microball assembly. The influence of various frequencies and accelerations on the performance was studied in detail. The measurement results of this electret micro power generator show that the optimal load is proportional to the frequency, and inversely proportional to the acceleration. The peak-to-peak output charge and output power were 72 nC and 5.9 µW respectively at 20 Hz and 0.7 g with the optimal resistive load 626 kΩ. The work frequencies range from 100 Hz to a lower frequency (1 Hz). 112 nW can still be obtained in the minimum acceleration of 0.05 g at 10 Hz with the optimal resistive load, indicating that this device has high sensitivity. The possible application of our device in scavenging energy from low-frequency irregular movements, such as human motion, was proved by a primary experiment

  19. Optimization of electret ionization chambers for dosimetry in mixed neutron-gamma fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.

    1984-01-01

    The properties of combination dosemeters consisting of two air-filled electret ionization chambers in mixed neutron-gamma fields have been investigated. The first chamber, polyethylene-walled, is sensitive to neutrons and gamma rays, the second, having walls of teflon, is sensitive to gamma rays only. The properties of the dosemeters are determined by the resulting errors and the measuring range. As both properties depend on the dimensions of the electret ionization chambers they have been taken into account in optimizing the dimensions. The results show that with the use of the dosemeters the effective dose equivalent in mixed neutron-gamma fields can be determined nearly independently of the spectra. The lower detection limit is less than 1 mSv and the maximum uncertainty of dose measurements about 12%. (author)

  20. Impulse-Excited Energy Harvester based on Potassium-Ion- Electret

    Science.gov (United States)

    Ashizawa, H.; Mitsuya, H.; Ishibashi, K.; Ishikawa, T.; Fujita, H.; Hashiguchi, G.; Toshiyoshi, H.

    2015-12-01

    We have developed an energy harvester that is specifically desired for impulse acceleration of infrastructure vibrations such as sudden motion at railway bridges. The energy harvester based on potassium-ion-electret on the sidewalls of 1.8- μm-gap comb electrodes generated a 64 μAp-p current during low impulse acceleration, which was large enough to light a green LED.

  1. Potassium ions in SiO2: electrets for silicon surface passivation

    Science.gov (United States)

    Bonilla, Ruy S.; Wilshaw, Peter R.

    2018-01-01

    This manuscript reports an experimental and theoretical study of the transport of potassium ions in thin silicon dioxide films. While alkali contamination was largely researched in the context of MOSFET instability, recent reports indicate that potassium ions can be embedded into oxide films to produce dielectric materials with permanent electric charge, also known as electrets. These electrets are integral to a number of applications, including the passivation of silicon surfaces for optoelectronic devices. In this work, electric field assisted migration of ions is used to rapidly drive K+ into SiO2 and produce effective passivation of silicon surfaces. Charge concentrations of up to ~5  ×  1012 e cm-2 have been achieved. This charge was seen to be stable for over 1500 d, with decay time constants as high as 17 000 d, producing an effectively passivated oxide-silicon interface with SRV  industrial manufacture of silicon optoelectronic devices.

  2. Measurements on low level plutonium sources using Rad Elec Electret Ion Chambers

    International Nuclear Information System (INIS)

    Levinskas, D.; Teagarden, J.; Wilkes, E.

    1998-01-01

    This is a technique for measuring gross alpha particle emission from interior contaminated surfaces. The technique utilizes electret ionization chambers (EICs), which consist of a charged Teflon plate (the electret) and an electrically-conductive plastic chamber of 145 ml volume. To measure very low levels of alpha contamination, the EIC is left in place on the surface to be measured for about 48 hours. The change in the surface charge of the electret is a measure of the ionization during the measurement period. The rate of change of the charge is converted into an activity using an appropriate calibration factor. This system has the ability to make accurate gross alpha contamination measurements while being subject to a high airborne radon concentration, such as might occur in certain buildings or during an atmospheric inversion. Previous studies of the effectiveness of these EIC's focused on levels of alpha contamination much higher than is allowed for unrestricted release of material at the Rocky Flats Environmental Technology Site (RFETS). This study evaluated the performance of EIC's at levels from 100 disintegrations per minute (dpm) per 100 cm 2 to below 20 dpm per 100 cm 2 (all measurements are referenced to a 4π geometry). The EIC's were found to be within 5% accuracy, as compared to a gas flow proportional counter calibrated with a NIST-traceable source. Test results indicate that the EIC, left in place for 48 hours, can detect alpha contamination as low as 6.4 ± 3.0 dpm/100 cm 2 to a 95% confidence level

  3. Relationship of Adhesive, Contact and Electret Properties of PTFE Modified by DC Discharge

    Science.gov (United States)

    Yablokov, M.; Piskarev, M.; Gilman, A.; Kechek'yan, A.; Kuznetsov, A.

    2018-02-01

    The relationship between the contact, adhesive and electret properties of PTFE films modified by direct current glow discharge has been studied. The film samples of 40 μm thickness were placed at the anode and cathode and treated in the air as a working gas. The contact properties of polymer surface were characterized by the values of deionized water contact angle. The peel strength was determined using T-peel test for the Scotch®810/PTFE film contact. The electret potential was measured by the compensation technique using dynamic capacitor, and from the measured potential value the effective surface charge density was calculated. It has been found that there is an undoubted correlation between the change in the value of water contact angle, the peel strength of the DC discharge-treated film, and the magnitude of the effective surface charge.

  4. Enhanced luminance for inorganic electroluminescent devices with a charged electret

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Fang-Hsing, E-mail: fansen@dragon.nchu.edu.tw [Department of Electrical Engineering and Graduate Institute of Optoelectronic Engineering, National Chung Hsing University, Taichung 402, Taiwan, ROC (China); Chen, Kuo-Feng [Department of Electrical Engineering and Graduate Institute of Optoelectronic Engineering, National Chung Hsing University, Taichung 402, Taiwan, ROC (China); Display Technology Center/Industrial Technology Research Institute, Hsinchu 310, Taiwan, ROC (China); Chien, Yu-Han; Chang, Chin-Chia; Chuang, Meng-Ying [Display Technology Center/Industrial Technology Research Institute, Hsinchu 310, Taiwan, ROC (China)

    2013-09-15

    This work proposes a novel inorganic electroluminescent (IEL) device with an electric field built-in (EFBI) technique to reduce its driving voltage and enhance its luminance. The EFBI technique was performed by charging an electret comprising a silicon dioxide film at different temperatures (25–150 °C) in powder electroluminescent (PDEL) devices. The driving voltage of the EFBI-PDEL device decreased by 61.4 V (or 20.5%) under the brightness of 269 cd/m{sup 2}, and its brightness increased by 128 cd/m{sup 2} (or 47%) at ac 300 V. The efficiency of the EFBI-PDEL device significantly increased by 0.827 lm/W (or 45.5%) at ac 300 V. The proposed EFBI-PDEL device has advantages of a low-temperature process and low cost, and potential for large-area display applications. -- Highlights: • An electric-field built-in powder electroluminescent (EFBI-PDEL) device is proposed. • The EFBI technique is performed by charging an electrets. • The driving voltage of the EFBI-PDEL device decreased by 20.5%. • The brightness of the EFBI-PDEL device increased by 47%. • The efficiency of the EFBI-PDEL device increased by 45.5%.

  5. The practical use of electrets in a public health radon remediation campaign

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Phillips, P.S.; Crockett, R.G.M.; Woolridge, A.; Gillmore, G.K.

    2005-01-01

    As part of a long-term assessment of domestic radon in Northamptonshire, England, a batch of 50 commercially available electrets was deployed for nearly 1000 exposures, individual exposure periods ranging from one to eight weeks. Responsivity was comparable with that of recently-calibrated Durridge RAD-7 continuously-monitoring equipment. Voltage history analysis indicated mean voltage decay during manufacturers' QA assessment of 0.059 ± 0.026 V day -1 , increasing to 0.114 ± 0.073 V day -1 during storage to first use and to 0.204 ± 0.49 V day -1 during inter-deployment storage. At a representative elevated radon concentration of 500 Bq m -3 , the resulting perturbation is 3% over a 7-day deployment; at the typical mean Northamptonshire level of 80 Bq m -3 it approaches 22%. Each electret can be used for up to 25 measurements, which makes the technology attractive for organisational use. It is not suited for deployment by individual householders

  6. Fabrication and performance of pressure-sensing device consisting of electret film and organic semiconductor

    Science.gov (United States)

    Kodzasa, Takehito; Nobeshima, Daiki; Kuribara, Kazunori; Uemura, Sei; Yoshida, Manabu

    2017-04-01

    We propose a new concept of a pressure-sensitive device that consists of an organic electret film and an organic semiconductor. This device exhibits high sensitivity and selectivity against various types of pressure. The sensing mechanism of this device originates from a modulation of the electric conductivity of the organic semiconductor film induced by the interaction between the semiconductor film and the charged electret film placed face to face. It is expected that a complicated sensor array will be fabricated by using a roll-to-roll manufacturing system, because this device can be prepared by an all-printing and simple lamination process without high-level positional adjustment for printing processes. This also shows that this device with a simple structure is suitable for application to a highly flexible device array sheet for an Internet of Things (IoT) or wearable sensing system.

  7. Design, modeling, fabrication and characterization of an electret-based MEMS electrostatic energy harvester

    NARCIS (Netherlands)

    Altena, G.; Hohlfeld, D.; Elfrink, R.; Goedbloed, M.H.; Schaijk, R. van

    2011-01-01

    This paper reports on the design, modelling, fabrication and characterization of an electret-based MEMS electrostatic energy harvester with an elegant and robust process flow. The fabrication is based on a SOI wafer with self-aligned electrodes of the variable capacitor. The output current of the

  8. Novel Organic Phototransistor-Based Nonvolatile Memory Integrated with UV-Sensing/Green-Emissive Aggregation Enhanced Emission (AEE)-Active Aromatic Polyamide Electret Layer.

    Science.gov (United States)

    Cheng, Shun-Wen; Han, Ting; Huang, Teng-Yung; Chang Chien, Yu-Hsin; Liu, Cheng-Liang; Tang, Ben Zhong; Liou, Guey-Sheng

    2018-05-30

    A novel aggregation enhanced emission (AEE)-active polyamide TPA-CN-TPE with a high photoluminesence characteristic was successfully synthesized by the direct polymerization of 4-cyanotriphenyl diamine (TPA-CN) and tetraphenylethene (TPE)-containing dicarboxylic acid. The obtained luminescent polyamide plays a significant role as the polymer electret layer in organic field-effect transistors (OFETs)-type memory. The strong green emission of TPA-CN-TPE under ultraviolet (UV) irradiation can be directly absorbed by the pentacene channel, displaying a light-induced programming and voltage-driven erasing organic phototransistor-based nonvolatile memory. Memory window can be effectively manipulated between the programming and erasing states by applying UV light illumination and electrical field, respectively. The photoinduced memory behavior can be maintained for over 10 4 s between these two states with an on/off ratio of 10 4 , and the memory switching can be steadily operated for many cycles. With high photoresponsivity ( R) and photosensitivity ( S), this organic phototransistor integrated with AEE-active polyamide electret layer could serve as an excellent candidate for UV photodetectors in optical applications. For comparison, an AEE-inactive aromatic polyimide TPA-PIS electret with much weaker solid-state emission was also applied in the same OFETs device architecture, but this device did not show any UV-sensitive and UV-induced memory characteristics, which further confirmed the significance of the light-emitting capability of the electret layer.

  9. Low-Frequency MEMS Electrostatic Vibration Energy Harvester With Corona-Charged Vertical Electrets and Nonlinear Stoppers

    Science.gov (United States)

    Lu, Y.; Cottone, F.; Boisseau, S.; Galayko, D.; Marty, F.; Basset, P.

    2015-12-01

    This paper reports for the first time a MEMS electrostatic vibration energy harvester (e-VEH) with corona-charged vertical electrets on its electrodes. The bandwidth of the 1-cm2 device is extended in low and high frequencies by nonlinear elastic stoppers. With a bias voltage of 46 V (electret@21 V + DC external source@25 V) between the electrodes, the RMS power of the device reaches 0.89 μW at 33 Hz and 6.6 μW at 428 Hz. The -3dB frequency band including the hysteresis is 223∼432 Hz, the one excluding the hysteresis 88∼166 Hz. We also demonstrate the charging of a 47 μF capacitor used for powering a wireless and autonomous temperature sensor node with a data transmission beyond 10 m at 868 MHz.

  10. Response identification in the extremely low frequency region of an electret condenser microphone.

    Science.gov (United States)

    Jeng, Yih-Nen; Yang, Tzung-Ming; Lee, Shang-Yin

    2011-01-01

    This study shows that a small electret condenser microphone connected to a notebook or a personal computer (PC) has a prominent response in the extremely low frequency region in a specific environment. It confines most acoustic waves within a tiny air cell as follows. The air cell is constructed by drilling a small hole in a digital versatile disk (DVD) plate. A small speaker and an electret condenser microphone are attached to the two sides of the hole. Thus, the acoustic energy emitted by the speaker and reaching the microphone is strong enough to actuate the diaphragm of the latter. The experiments showed that, once small air leakages are allowed on the margin of the speaker, the microphone captured the signal in the range of 0.5 to 20 Hz. Moreover, by removing the plastic cover of the microphone and attaching the microphone head to the vibration surface, the low frequency signal can be effectively captured too. Two examples are included to show the convenience of applying the microphone to pick up the low frequency vibration information of practical systems.

  11. Response Identification in the Extremely Low Frequency Region of an Electret Condenser Microphone

    Directory of Open Access Journals (Sweden)

    Shang-Yin Lee

    2011-01-01

    Full Text Available This study shows that a small electret condenser microphone connected to a notebook or a personal computer (PC has a prominent response in the extremely low frequency region in a specific environment. It confines most acoustic waves within a tiny air cell as follows. The air cell is constructed by drilling a small hole in a digital versatile disk (DVD plate. A small speaker and an electret condenser microphone are attached to the two sides of the hole. Thus, the acoustic energy emitted by the speaker and reaching the microphone is strong enough to actuate the diaphragm of the latter. The experiments showed that, once small air leakages are allowed on the margin of the speaker, the microphone captured the signal in the range of 0.5 to 20 Hz. Moreover, by removing the plastic cover of the microphone and attaching the microphone head to the vibration surface, the low frequency signal can be effectively captured too. Two examples are included to show the convenience of applying the microphone to pick up the low frequency vibration information of practical systems.

  12. Broad bandwidth vibration energy harvester based on thermally stable wavy fluorinated ethylene propylene electret films with negative charges

    Science.gov (United States)

    Zhang, Xiaoqing; Sessler, Gerhard M.; Ma, Xingchen; Xue, Yuan; Wu, Liming

    2018-06-01

    Wavy fluorinated ethylene propylene (FEP) electret films with negative charges were prepared by a patterning method followed by a corona charging process. The thermal stability of these films was characterized by the surface potential decay with annealing time at elevated temperatures. The results show that thermally stable electret films can be made by corona charging followed by pre-aging treatment. Vibration energy harvesters having a very simple sandwich structure, consisting of a central wavy FEP electret film and two outside metal plates, were designed and their performance, including the resonance frequency, output power, half power bandwidth, and device stability, was investigated. These harvesters show a broad bandwidth as well as high output power. Their performance can be further improved by using a wavy-shaped counter electrode. For an energy harvester with an area of 4 cm2 and a seismic mass of 80 g, the output power referred to 1 g (g is the gravity of the earth), the resonance frequency, and the 3 dB bandwidth are 1.85 mW, 90 Hz, and 24 Hz, respectively. The output power is sufficient to power some electronic devices. Such devices may be embedded in shoe soles, carpets or seat cushions where the flexibility is required and large force is available.

  13. Photon correlation spectroscopic analysis of a natural electret material: Carnauba wax

    Science.gov (United States)

    Barbosa, G. A.; Russi, R.; Pires, A. S. T.; Mesquita, O. N.

    1981-02-01

    For the first time, photon correlation spectroscopy is applied to the study of an electret material. We show that the average self-diffusion parameter of Carnauba wax in liquid phase, from 85 to 170 °C can be written as D=D0+A exp[-ΔE/k(T-T0)], where D0=1.6×10-10 and A=20×10-10 cm2/sec, ΔE=82 cm-1 and T0=68 °C

  14. Dosimetry in radiodiagnosis. Individual irradiation card. Dosimetric application of electrets

    International Nuclear Information System (INIS)

    Lisbona, Albert.

    1981-09-01

    This study deals with a radiodiagnosis dosimetry, and contains two parts. First of all, the combination between a dosimetric data acquisition from an ionization chamber and a micro-computer allows the realization of individual irradiation card for a well established examination. The method is extensible to almost totality of radiological examinations. The second part describes the following of an original work about the application of electrets in radiodiagnosis dosimetry. At least a theorical study is shown; it takes account of different involving phenomena and allows a starting interpretation of experimental results [fr

  15. An effective flexible wireless energy harvester/sensor based on porous electret piezoelectric polymer

    Energy Technology Data Exchange (ETDEWEB)

    Mahanty, Biswajit [Organic Nano-Piezoelectric Device Laboratory, Department of Physics, Jadavpur University, Kolkata, 700032 (India); Department of Electronics and Communication Engineering, Saroj Mohan Institute of Technology, Hooghly, 712512 (India); Ghosh, Sujoy Kumar; Garain, Samiran [Organic Nano-Piezoelectric Device Laboratory, Department of Physics, Jadavpur University, Kolkata, 700032 (India); Mandal, Dipankar, E-mail: dipankar@phys.jdvu.ac.in [Organic Nano-Piezoelectric Device Laboratory, Department of Physics, Jadavpur University, Kolkata, 700032 (India)

    2017-01-15

    A flexible sponge-like nanogenerator (FSNG) based on ZnO nanoparticles (NPs) etched porous electret poly (vinylidene fluoride–hexafluoropropylene) (P(VDF-HFP)) film is spotlighted without any electrical poling treatment. It possesses improved dielectric and ferroelectric properties than neat P(VDF-HFP) film. The FSNG harvests an open-circuit voltage (V{sub oc}) of 9 V and short circuit current (I{sub sc}) of 1.3 μAcm{sup −2} under repeated mechanical impact of 0.36 MPa stress amplitude on the top surface. With the power density (P) of 1.21 mW/cm{sup 2} and energy conversion efficiency of 0.3% it directly operates several consumer electronics. The highly sensitive (∼1 μVPa{sup −1}) FSNG is demonstrated as a self-powered wireless sensor with 3.0% efficiency for detecting some tiny human activities including finger movements. - Highlights: • ZnO nanoparticles etched porous electret P(VDF-HFP) film is spot lighted. • Superior dielectric and ferroelectric properties without any poling are observed. • It harvests 9 V output voltage with 4.7 μA current under 0.36 MPa stress. • It shows superior power density and energy conversion efficiency of same stress. • It also acts as self-powered wireless sensor for detecting tiny human activities.

  16. Emergent electromechanical coupling of electrets and some exact relations — The effective properties of soft materials with embedded external charges and dipoles

    Science.gov (United States)

    Liu, Liping; Sharma, Pradeep

    2018-03-01

    Soft robotics, energy harvesting, large-deformation sensing and actuation, are just some of the applications that can be enabled by soft dielectrics that demonstrate substantive electromechanical coupling. Most soft dielectrics including elastomers, however, are not piezoelectric and rely on the universally present electrostriction and the Maxwell stress effect to enable the aforementioned applications. Electrostriction is a one-way electromechanical coupling and the induced elastic strain scales as (∝E2) upon the application of an electric field, E. The quadratic dependence of electrostriction on the electric field and the one-way coupling imply that, (i) A rather high voltage is required to induce appreciable strain, (ii) reversal of an applied bias will not reverse the sign of the deformation, and (iii) since it is a one-way coupling i.e. electrical stimuli may cause mechanical deformation but electricity cannot be generated by mechanical deformation, prospects for energy harvesting are rather difficult. An interesting approach for realizing an apparent piezoelectric-like behavior is to dope soft dielectrics with immobile charges and dipoles. Such materials, called electrets, are rather unique composites where a secondary material (in principle) is not necessary. Both experiments and supporting theoretical work have shown that soft electrets can exhibit a very large electromechanical coupling including a piezoelectric-like response. In this work, we present a homogenization theory for electret materials and provide, in addition to several general results, variational bounds and closed-form expressions for specific microstructures such as laminates and ellipsoidal inclusions. While we consider the nonlinear coupled problem, to make analytical progress, we work within the small-deformation setting. The specific conditions necessary to obtain a piezoelectric-like response and enhanced electrostriction are highlighted. There are very few universal, microstructure

  17. Electret ionization chamber: a new method for detection and dosimetry of thermal neutrons; Camara de ionizacao de eletretos: um novo metodo para deteccao e dosimetria de neutrons termicos

    Energy Technology Data Exchange (ETDEWEB)

    Ghilardi, A J.P.

    1988-12-31

    An electret ionization chamber with boron coated walls is presented as a new method for detecting thermal neutrons. The efficiency of electret ionization chambers with different wall materials for the external electrode was inferred from the results. Detection of slow neutrons with discrimination against the detection of {gamma}-rays and energetic neutrons was shown to depend on the selection of these materials. The charge stability over a long period of time and the charge decay owing to natural radiation were also studied. Numerical analysis was developed by the use of a micro-computer PC-XT. Both the experimental and numerical results show that the sensitivity of the electret ionization chamber for detection of thermal neutrons is comparable with that of the BF{sub 3} ionization chamber and that new technologies for deposition of the boron layer will produce higher efficiency detectors. (author). 102 refs, 32 fig, 10 tabs.

  18. Study about the feasibility of using an electret dosemeter as a personal dosemeter

    International Nuclear Information System (INIS)

    Leitao, I.P.

    1983-01-01

    A feasibility study of the electret dosemeters as a personnel dosemeter was carried out. Preliminary tests were applied, in order to assess the dosemeter response to radiation, linearity, stability, reproductibility, direcional dependence and energy dependence in energy range from 33 to 1250 KeV. In general the results are in agreement with the recommendations of the Commision of the European Communities (CEC) for the use of this device as a personnel dosemeter with the exception of the energy dependence and the stability at medium term. (Author) [pt

  19. An electret-based energy harvesting device with a wafer-level fabrication process

    DEFF Research Database (Denmark)

    Crovetto, Andrea; Wang, Fei; Hansen, Ole

    2013-01-01

    This paper presents a MEMS energy harvesting device which is able to generate power from two perpendicular ambient vibration directions. A CYTOP polymer is used both as the electret material for electrostatic transduction and as a bonding interface for low-temperature wafer bonding. The device...... is also discussed. With a final chip size of about 1 cm2, a power output of 32.5 nW is successfully harvested with an external load of 17 MΩ, when a harmonic vibration source with an RMS acceleration amplitude of 0.03 g (∼0.3 m s−2) and a resonant frequency of 179 Hz is applied. These results can...

  20. Piezoelectricity and ferroelectricity of cellular polypropylene electrets films characterized by piezoresponse force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Hongchen; Sun, Yao; Zhou, Xilong; Li, Yingwei [LTCS and Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing 100871 (China); Li, Faxin, E-mail: lifaxin@pku.edu.cn [LTCS and Department of Mechanics and Engineering Science, College of Engineering, Peking University, Beijing 100871 (China); HEDPS and Center for Applied Physics and Technology, Peking University, Beijing (China)

    2014-08-14

    Cellular electrets polymer is a new ferroelectret material exhibiting large piezoelectricity and has attracted considerable attentions in researches and industries. Property characterization is very important for this material and current investigations are mostly on macroscopic properties. In this work, we conduct nanoscale piezoelectric and ferroelectric characterizations of cellular polypropylene (PP) films using piezoresponse force microscopy (PFM). First, both the single-frequency PFM and dual-frequency resonance-tracking PFM testings were conducted on the cellular PP film. The localized piezoelectric constant d{sub 33} is estimated to be 7–11pC/N by correcting the resonance magnification with quality factor and it is about one order lower than the macroscopic value. Next, using the switching spectroscopy PFM (SS-PFM), we studied polarization switching behavior of the cellular PP films. Results show that it exhibits the typical ferroelectric-like phase hysteresis loops and butterfly-shaped amplitude loops, which is similar to that of a poly(vinylidene fluoride) (PVDF) ferroelectric polymer film. However, both the phase and amplitude loops of the PP film are intensively asymmetric, which is thought to be caused by the nonzero remnant polarization after poling. Then, the D-E hysteresis loops of both the cellular PP film and PVDF film were measured by using the same wave form as that used in the SS-PFM, and the results show significant differences. Finally, we suggest that the ferroelectric-like behavior of cellular electrets films should be distinguished from that of typical ferroelectrics, both macroscopically and microscopically.

  1. Manipulation of electron transport in graphene by nanopatterned electrostatic potential on an electret

    Science.gov (United States)

    Wang, Xiaowei; Wang, Rui; Wang, Shengnan; Zhang, Dongdong; Jiang, Xingbin; Cheng, Zhihai; Qiu, Xiaohui

    2018-01-01

    The electron transport characteristics of graphene can be finely tuned using local electrostatic fields. Here, we use a scanning probe technique to construct a statically charged electret gate that enables in-situ fabrication of graphene devices with precisely designed potential landscapes, including p-type and n-type unipolar graphene transistors and p-n junctions. Electron dynamic simulation suggests that electron beam collimation and focusing in graphene can be achieved via periodic charge lines and concentric charge circles. This approach to spatially manipulating carrier density distribution may offer an efficient way to investigate the novel electronic properties of graphene and other low-dimensional materials.

  2. Improved mechanical reliability of MEMS electret based vibration energy harvesters for automotive applications

    International Nuclear Information System (INIS)

    Renaud, M; Goedbloed, M; De Nooijer, C; Van Schaijk, R; Fujita, T

    2014-01-01

    Current commercial wireless tire pressure monitoring systems (TPMS) require a battery as electrical power source. The battery limits the lifetime of the TPMS. This limit can be circumvented by replacing the battery by a vibration energy harvester. Autonomous wireless TPMS powered by MEMS electret based vibration energy harvester have been demonstrated. A remaining technical challenge to attain the grade of commercial product with these autonomous TPMS is the mechanical reliability of the MEMS harvester. It should survive the harsh conditions imposed by the tire environment, particularly in terms of mechanical shocks. As shown in this article, our first generation of harvesters has a shock resilience of 400 g, which is far from being sufficient for the targeted application. In order to improve this aspect, several types of shock absorbing structures are investigated. With the best proposed solution, the shock resilience of the harvesters is brought above 2500 g

  3. A study of airborne radon levels in Paarl houses (South Africa) and associated source terms, using electret ion chambers and gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, R. [Department of Physics, University of the Western Cape, Private Bag X17, Bellville 7537 (South Africa)], E-mail: rlindsay@uwc.ac.za; Newman, R.T. [Environmental Radioactivity Laboratory, Physics Group, iThemba LABS, P.O. Box 722, Somerset West 7129 (South Africa); Speelman, W.J. [Department of Physics, University of the Western Cape, Private Bag X17, Bellville 7537 (South Africa)

    2008-11-15

    Indoor radon ({sup 222}Rn) concentrations were measured in Paarl homes by means of electret ion chambers. The concentrations varied between 28 and 465 Bq m{sup -3}. The average values (Bq m{sup -3}) found in houses on the west and east side of the Berg River, which bisects Paarl, were 132 ({+-}11) and 37 ({+-}3), respectively. Radiometric analyses of soils show that the mean {sup 226}Ra activity concentration is three times higher on the west than on the east side of the Berg River.

  4. A study of airborne radon levels in Paarl houses (South Africa) and associated source terms, using electret ion chambers and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Lindsay, R.; Newman, R.T.; Speelman, W.J.

    2008-01-01

    Indoor radon ( 222 Rn) concentrations were measured in Paarl homes by means of electret ion chambers. The concentrations varied between 28 and 465 Bq m -3 . The average values (Bq m -3 ) found in houses on the west and east side of the Berg River, which bisects Paarl, were 132 (±11) and 37 (±3), respectively. Radiometric analyses of soils show that the mean 226 Ra activity concentration is three times higher on the west than on the east side of the Berg River

  5. Shock reliability analysis and improvement of MEMS electret-based vibration energy harvesters

    International Nuclear Information System (INIS)

    Renaud, M; Goedbloed, M; De Nooijer, C; Van Schaijk, R; Fujita, T

    2015-01-01

    Vibration energy harvesters can serve as a replacement solution to batteries for powering tire pressure monitoring systems (TPMS). Autonomous wireless TPMS powered by microelectromechanical system (MEMS) electret-based vibration energy harvester have been demonstrated. The mechanical reliability of the MEMS harvester still has to be assessed in order to bring the harvester to the requirements of the consumer market. It should survive the mechanical shocks occurring in the tire environment. A testing procedure to quantify the shock resilience of harvesters is described in this article. Our first generation of harvesters has a shock resilience of 400 g, which is far from being sufficient for the targeted application. In order to improve this aspect, the first important aspect is to understand the failure mechanism. Failure is found to occur in the form of fracture of the device’s springs. It results from impacts between the anchors of the springs when the harvester undergoes a shock. The shock resilience of the harvesters can be improved by redirecting these impacts to nonvital parts of the device. With this philosophy in mind, we design three types of shock absorbing structures and test their effect on the shock resilience of our MEMS harvesters. The solution leading to the best results consists of rigid silicon stoppers covered by a layer of Parylene. The shock resilience of the harvesters is brought above 2500 g. Results in the same range are also obtained with flexible silicon bumpers, which are simpler to manufacture. (paper)

  6. Shock reliability analysis and improvement of MEMS electret-based vibration energy harvesters

    Science.gov (United States)

    Renaud, M.; Fujita, T.; Goedbloed, M.; de Nooijer, C.; van Schaijk, R.

    2015-10-01

    Vibration energy harvesters can serve as a replacement solution to batteries for powering tire pressure monitoring systems (TPMS). Autonomous wireless TPMS powered by microelectromechanical system (MEMS) electret-based vibration energy harvester have been demonstrated. The mechanical reliability of the MEMS harvester still has to be assessed in order to bring the harvester to the requirements of the consumer market. It should survive the mechanical shocks occurring in the tire environment. A testing procedure to quantify the shock resilience of harvesters is described in this article. Our first generation of harvesters has a shock resilience of 400 g, which is far from being sufficient for the targeted application. In order to improve this aspect, the first important aspect is to understand the failure mechanism. Failure is found to occur in the form of fracture of the device’s springs. It results from impacts between the anchors of the springs when the harvester undergoes a shock. The shock resilience of the harvesters can be improved by redirecting these impacts to nonvital parts of the device. With this philosophy in mind, we design three types of shock absorbing structures and test their effect on the shock resilience of our MEMS harvesters. The solution leading to the best results consists of rigid silicon stoppers covered by a layer of Parylene. The shock resilience of the harvesters is brought above 2500 g. Results in the same range are also obtained with flexible silicon bumpers, which are simpler to manufacture.

  7. Figure of merit comparison of PP-based electret and PVDF-based piezoelectric polymer energy harvesters

    Science.gov (United States)

    Mrlík, M.; Leadenham, S.; AlMaadeed, M. A.; Erturk, A.

    2016-04-01

    The harvesting of mechanical strain and kinetic energy has received great attention over the past two decades in order to power wireless electronic components such as those used in passive and active monitoring applications. Piezoelectric ceramics, such as PZT (lead zirconate titanate), constitute the most commonly used electromechanical interface in vibration energy harvesters. However, there are applications in which piezoelectric ceramics cannot be used due to their low allowable curvature and brittle nature. Soft polymer PVDF (polyvinylidene fluoride) is arguably the most popular non-ceramic soft piezoelectric energy harvester material for such scenarios. Another type of polymer that has received less attention is PP (polypropylene) for electret-based energy harvesting using the thickness mode (33- mode). This work presents figure of merit comparison of PP versus PVDF for off-resonant energy harvesting in thickness mode operation, revealing substantial advantage of PP over PVDF. For thickness mode energy harvesting scenarios (e.g. dynamic compression) at reasonable ambient vibration frequencies, the figure of merit for the maximum power output is proportional to the square of the effective piezoelectric strain constant divided by the effective permittivity constant. Under optimal conditions and for the same volume, it is shown that PP can generate more than two orders of magnitude larger electrical power as compared to PVDF due to the larger effective piezoelectric strain constant and lower permittivity of the former.

  8. Direct determination of 222Rn gas using the electret to remove daughters at formation. Annual progress report, June 1, 1981-May 31, 1982

    International Nuclear Information System (INIS)

    Harley, N.H.

    1982-01-01

    This report covers progress made from 1 June 1981 to 31 May 1982 in developing a continuous monitor which measures only 222 Rn without interference from the daughters. Five 222 Rn counters have been built which determine 222 Rn alone by alpha scintillation counting in the presence of an electret to remove the short-lived daughter products from the counting chamber. The chamber design is based on the work of Chittaporn et al., (1981) at New York University's Department of Environmental Medicine. The detection chamber is a 1.8 liter (12.7 cm diameter by 14 cm high) cylinder lined with zinc sulfide alpha phosphor. The detector sits directly on a 12.7 cm diameter phototube. The 5 units have calibration factors which range from 155 to 186 counts/hour per pCi 222 Rn/liter and an average background count of 6 counts/hour. The lower limit of detection for a one hour count is thus 0.03 pCi 222 Rn/l, well below environmental levels

  9. Studying the possibility of recharging E-Perm for radon measurement in air

    International Nuclear Information System (INIS)

    Shweikani, R.; Bardan, R.

    2011-03-01

    In this work recharging electret detectors and studying their responding for radioactive gases (radon gas) was studied and the results were compared with solid state nuclear detectors (CR-39). After several experiments we found that using a metal nozzle which is connected to a high voltage supply (poling method) was useful to polarize the electret material and get a stable electrostatic charge. The stability of electret was studied after each experiment ,the results showed that the best charging parameters were: (7 mm as a nozzle height.- 15 sec as a charging time.- 5 kV as a charging voltage). Depending on the charging and stability studying results the electrets were calibrated in radon calibration cell and the calibration factors were defined The charged electrets were examined to measure radon concentration in the open environmental and were compared with CR-39 detectors; the charged electrets appeared a liner response for radon gas as CR-39 detectors.(author)

  10. Electromagnetic Machines Which Utilize Microgeometry Field Structures

    Science.gov (United States)

    1990-04-01

    34Phenomenological Theory of Electret Discharge Including Incomplete Recombination of Ions". Acta Physica Polonica , A50(1)1 1. Mehendru, P.C. (177)(: "Electret...Resonance of Stabilized Electrons in PTFE Coronoelectrets". Physica Status Solidi, (a)90:K71-K74. Lagues, M. (1976): "Les Electrets: des Transducteurs

  11. Radon diffusion chamber

    International Nuclear Information System (INIS)

    Pretzsch, G.; Boerner, E.; Lehmann, R.; Sarenio, O.

    1986-01-01

    The invention relates to the detection of radioactive gases emitting alpha particles like radon, thoron and their alpha-decaying daughters by means of a diffusion chamber with a passive detector, preferably with a solid state track detector. In the chamber above and towards the detector there is a single metallized electret with negative polarity. The distance between electret and detector corresponds to the range of the alpha particles of radon daughters in air at the most. The electret collects the positively charged daughters and functions as surface source. The electret increases the sensitivity by the factor 4

  12. Thermal energy harvesters with piezoelectric or electrostatic transducer

    Science.gov (United States)

    Prokaryn, Piotr; Domański, Krzysztof; Marchewka, Michał; Tomaszewski, Daniel; Grabiec, Piotr; Puscasu, Onoriu; Monfray, Stéphane; Skotnicki, Thomas

    2014-08-01

    This paper describes the idea of the energy harvester which converts thermal gradient present in environment into electricity. Two kinds of such devices are proposed and their prototypes are shown and discussed. The main parts of harvesters are bimetallic spring, piezoelectric transducer or electrostatic transducer with electret. The applied piezomembrane was commercial available product but electrets was made by authors. In the paper a fabrication procedure of electrets formed by the corona discharge process is described. Devices were compared in terms of generated power, charging current, and the voltage across a storage capacitor.

  13. Nano ZnO embedded in Chitosan matrix for vibration sensor application

    Science.gov (United States)

    Praveen, E.; Murugan, S.; Jayakumar, K.

    2015-06-01

    Biopolymer Chitosan is embedded with various concentration of ZnO nano particle and such a bio-nano composite electret has been fabricated by casting method. The morphological, structural, optical and electrical characterization of the bio-nano composite electret film have been carried out. Isolation and piezoelectric measurements of bio-nano composite have also been carried out indicating the possibility of using it as a mechanical sensor element.

  14. Project R43.106: Field trails of a passive dust sampler in mines: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M. [Health and Safety Laboratory, Sheffield (United Kingdom). Environmental Measurement Groups

    1999-12-01

    Electret based passive dust samplers developed by the project were tested in four collieries in the United Kingdom and compared with MRE gravimetric site samplers (Casella type 113A) and CIP10 samplers (Capteur Indivuel de Poussiere 10 made by Arelco, France). Results of site sampling and personal sampling was assessed according to the draft-CFB standard (1998). The sampler did not satisfy the CEN criteria when results from all the collieries were analysed and therefore a general calibration function suitable for all mines could not be used. In the severe conditions of the coal mines, 62% of the passive samplers failed because the electrets lost more than 70% of their initial surface charge. Work is recommended on improving the charge stability of the electrets. 7 refs., 6 figs., 1 app.

  15. Influence of radiation on coronoelectrets based on polymer compositions of polypropylene and polyethylene

    International Nuclear Information System (INIS)

    Aliyev, A.A.

    2010-11-01

    Determination of non-equilibrium charge relaxation mechanism in dielectric films has a large scientific and practice interest in connection with application of dielectric films in microelectronics, electret techniques, electro photography and in other areas. However, a lot of questions connected with relaxation of non-equilibrium charge in nonpolar thin film polymers stay unsolved. In particular, the questions on determination of criteria rating to relaxation processes in nonpolar dielectrics to which numerous relaxation models known at present, on structure of trap energy spectra, on geometric displacing of traps and etc. are not studied. These factors make difficulties for interpretation of experimental results. With the purpose of study of preliminary influence of gamma-radiation on stability of coronoelectrets of PE, PP, and their mixes, electrets properties of HDPE/PP mixes at range of addition one of components (up to 10 percent) and influence of preliminary gamma-radiation in air up to dose 10 Mrad are investigated. Isotropic films of HDPE/PP, LDPE/PP with 50 percent mass concentration and 60-120 mkm thickness were obtained from melt, then were polarized by unipolar corona discharge in the electrodes system of needle - plate at distance of 1 cm between them, 5 min. change time of and 7 kV voltage. The electrets surface density charges from LD PEwith PP components irradiated by 3-5 Mrad dose is always below than at initial PELD transits through a maximum approximately in the field of 10 % masses of the PP component. PP Components in PELD excite magnification of electrets charge density (especially 10 percent masses), but in due course storages this effect less we shall feel and approximately in 720 hours, quantities of electrets charge effective surface density basically are commensurable. Preliminary gamma-radiation by 3 and 5 Mrad doses raises the quantity of surface density of electrets from intermixtures of PP-LDPE and LDPE-PP and the irradiated samples

  16. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room

    Directory of Open Access Journals (Sweden)

    Huan Ma

    2016-01-01

    Full Text Available Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE medium shows better initial removal efficiency than the high efficiency (HE medium in the 0.3–3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 104 m3/m2. The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC with the pre-filter (PR or the active carbon granule filter (CF was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE showed maximum single-pass efficiency for PM1.0 (88.6%, PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4–0.65 μm exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in

  17. Electric dosemeters. Application in radiodiagnosis

    International Nuclear Information System (INIS)

    Ricard, Marcel.

    1980-06-01

    This work relates the realization of an useful dosimeter in radiodiagnosis. The detection is founded on depolarization measurement of an electret submitted to X rays. First of all we have studied several methods for the making of electrets with a polymer tip of low thickness (100 μm). Is described an assembly for the making and carrying out of the samples measurement. Are also presented the results obtained by two polarization methods. The relative importance of the two mechanisms which stem out from these results are discussed in the last part. The shape of the curves is justified [fr

  18. Intercomparison of radon gas detectors 1999 and 2000 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck, Gernot

    2000-10-01

    This report describes the results of two radon intercomparison exercises performed by the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut from Sep 9th to Oct 6th, 1999, and from March 21st to 28th, 2000. Radon gas detectors and instruments were exposed in the PSI Radon Chamber in reference atmospheres to 1060 kBqhm -3 radon gas exposure at an average radon gas concentration of 6400 Bqm -3 and to 2050 kBqhm -3 radon gas exposure at an average radon gas concentration of 12500 Bqm -3 , respectively. These intercomparison exercises determined the performance of electret ionisation chambers, track etch detectors and measuring instruments at high humidity (1999 Intercomparison Exercise) and at a high radon gas exposure (2000 Intercomparison Exercise). In the 1999 Intercomparison Exercise, electret ionisation chambers revealed an influence on high humidity. This effect may be due to impurities on a microscopic scale on the electrets of these detectors. With few exceptions, in both the 1999 and the 2000 Radon Intercomparison Exercise the deviations of the measurement results to the reference radon gas concentration values were less than 15% (traceability criterion) and the standard deviation of the results of five detectors less than 15% (reproducibility criterion). (author) [de

  19. E-perm radon monitors for determining waterborne concentrations of dissolved in radon 222Rn

    International Nuclear Information System (INIS)

    Jester, W.A.; Kotrappa, P.

    1989-01-01

    This paper describes a simple and relatively inexpensive method in which E-Perm radon monitors are used to determine the concentration of dissolved 222 Rn in drinking water. This procedure takes advantage of E-Perm's ability to accurately measure the integral radon exposure under conditions of high humidity. The method was evaluated against the liquid scintillation procedure recommended by the U.S. Environmental Protection Agency (EPA) and was found to give excellent agreement. An E-perm is an electret ion chamber that consists of a small chamber constructed from a conducting plastic and having an electret at its base and a filtered air inlet at the top. The technique described in this paper takes advantages of E-Perm's insensitivity to high humidity

  20. MEMS fabricated energy harvesting device with 2D resonant structure

    DEFF Research Database (Denmark)

    Crovetto, Andrea; Wang, Fei; Triches, Marco

    This paper reports on a MEMS energy harvester able to generate power from two perpendicular ambient vibration directions. CYTOP polymer is used both as the electret material for electrostatic transduction and as a bonding interface for low-temperature wafer bonding. With final chip size of ~1 cm2......, an output power of 32.5 nW is reached with an external load of 17 MΩ, under a harmonic source motion with acceleration RMS amplitude 0.03 g (0.3 m/s2) and frequency 179 Hz.......This paper reports on a MEMS energy harvester able to generate power from two perpendicular ambient vibration directions. CYTOP polymer is used both as the electret material for electrostatic transduction and as a bonding interface for low-temperature wafer bonding. With final chip size of ~1 cm2...

  1. Trap-controlled charge transport in corona-charged Teflon

    International Nuclear Information System (INIS)

    Gross, B.; Giacometti, J.A.; Ferreira, G.F.L.; Moreno A, R.A.

    1980-01-01

    The stability of negatively charged Teflon electrets is discussed. It is stated that it can only be explained by the assumption that the transport of excess charge is trap - controlled rather than mobility - controlled. (I.C.R.) [pt

  2. Measured radon inside housings the Republic Argentina

    International Nuclear Information System (INIS)

    Canoba, A.; Arnaud, M.; Lopez, F.; Oliveira, A.A.

    1998-01-01

    They have been measured the radon concentration in houses in different city's in Argentina Republic. For they were used it as method mensuration detectors appearances nuclear detecting electrets and detectors based on the adsorption radon in activated carbon

  3. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 30; Issue 2 ... TSDC; PS; naphthalene; thermo-electrets; glass transition temperature (g). Abstract. The electrical conductivity of naphthalene doped polystyrene (PS) films (≈ 61.58 m thick) was studied as a function of dopant concentration and temperature.

  4. Reactive ion etching of polymer materials for an energy harvesting device

    DEFF Research Database (Denmark)

    Wang, Fei; Bertelsen, Christian Vinther; Skands, Gustav

    2012-01-01

    In this paper, we have demonstrated deep reactive ion etching (RIE) of two MEMS compatible polymer materials CYTOP and TOPAS, which may be useful for energy harvesting devices. The CYTOP polymer was patterned and used as the electret for the following corona charging while the TOPAS polymer...

  5. and poly(methyl methacrylate)

    Indian Academy of Sciences (India)

    materials forming electrets. Thermally stimulated discharge. (TSD) is a conventional technique for investigation of charge storage and transport processes in high resistivity materi- als and devices. For the standard TSD experiment, which is comparable to a dielectric loss measurement, the low equi- valent frequency (≈ 10.

  6. Intercomparison 2003 for Radon measurement services at PSI

    CERN Document Server

    Butterweck, G

    2003-01-01

    Twelve radon measurement services participated in the 2003 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut (PSI) during March 13th to 24th, 2003. Ten of these laboratories were approved by the Swiss Federal Office of Public Health and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas detectors (etched-track and electret ionisation chambers) and instruments (ionisation chambers and electrostatic precipitation) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 1950 Bqm sup - sup 3 leading to a radon gas exposure of 517 kBqhm sup - sup 3. Additional five electret-detectors of an approved measuring service were purchased by the Swiss Federal Office of Public Health for a spot check. Two of these were exposed as described above, two had an exposure of 247 kBqhm sup - sup 3 at an average radon concen...

  7. HEMISPHERIC CENTER FOR ENVIRONMENTAL TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Ebadian

    1999-03-30

    A vendor was selected for the diamond wire technology demonstration scheduled for this summer at Princeton Plasma Physics Laboratory (PPPL). A team consisting of personnel from FIU-HCET, PPPL, and AEA Technology reviewed the submitted bids. FIU-HCET will contract this vendor. At the SRS Ninth ICT teleconference, the ICT team discussed the status of the following demonstrations: LRAD; x-ray, K-edge; Strippable Coatings; Thermal Spray Vitrification; Cutting/Shearing/Dismantlement/Size Reduction; and Electrets. The LRAD demo is complete, and the x-ray/K-edge, Strippable Coatings, and Electrets demos are ongoing. The Asbestos and Thermal Spray Vitrification demos require more laboratory testing. The Cutting/Shearing/Dismantlement/Size Reduction demo is undergoing procurement. Five FIU-HCET staff members took the 1S0 14000 environmental auditor training course February 22-26, 1999, given by ASC. The test plan for the Facility Dismantlement Technology Assessment is finished and ready for internal review.

  8. Micromechanical Sensor for the Spectral Decomposition of Acoustic Signals

    Science.gov (United States)

    2012-02-01

    PZT Driver ......................................................... 226 Figure 7.3: PZT Driver...Gravity Abbreviations AF Amorphous Film ECM Electret Condenser Microphone FEA Finite Element Analysis FWHM Full Width Half Maximum PZT Lead...and/or critical equipment, such as rotating machinery and structural components, for signs of wear and fatigue . The first application, impact

  9. General considerations of noise in microphone preamplifiers

    NARCIS (Netherlands)

    van der Donk, A.G.H.; van der Donk, A.G.H.; Voorthuyzen, J.A.; Voorthuyzen, J.A.; Bergveld, Piet

    1991-01-01

    In this paper a study of the noise performance of electret microphone systems as a part of hearing aids is presented. The signal-to-noise ratio of the microphone-preamplifier combination, containing a field-effect transistor (FET) and a high value resistive bias element in a hybrid configuration, is

  10. MICROMECHANICAL MICROPHONE

    DEFF Research Database (Denmark)

    1997-01-01

    and dirt, which partly or totally will be able to destroy its characteristics, a sealing acoustic membrane (6, 7) is placed on each side of the transducer element. The transducer element can for example be a capacitive transducer with external bias or an electret based transducer. The microphone, which can...

  11. The influence of thoron on measurement results of radon exhalation rate

    CERN Document Server

    Xiao De Tao; Ling Qiu; Leung, J K C

    2002-01-01

    Because of thoron exhalation, the measurement results of radon exhalation rate using a local still method is usually larger than the true value of radon flux rate of the monitored material surface. The influence of sup 2 sup 1 sup 6 Po(ThA) on radon exhalation rate can be eliminated for sensitive radon monitors. Theoretical evaluations of the influence of sup 2 sup 1 sup 2 Bi(ThC) and sup 2 sup 1 sup 2 Po(ThC')on radon exhalation rate are carried out in a sampler with diameter of 188 mm, and height of 125 mm, and supplied electrostatic field inside (generated by high voltage and electret) under following conditions: the sampling time are 1, 2, 3 h, respectively, thoron exhalation rate is 100 times of radon's. The calculation results indicate that the measurement results of radon flux rate are possibly 35.5% larger than true value due to the influence of thoron for fast and multifunctional radon monitors with electret, high voltage, respectively and using CR-39 SSNTD as detector, but this influence is negligib...

  12. Semi-flexible bimetal-based thermal energy harvesters

    International Nuclear Information System (INIS)

    Boisseau, S; Despesse, G; Monfray, S; Puscasu, O; Skotnicki, T

    2013-01-01

    This paper introduces a new semi-flexible device able to turn thermal gradients into electricity by using a curved bimetal coupled to an electret-based converter. In fact, a two-step conversion is carried out: (i) a curved bimetal turns the thermal gradient into a mechanical oscillation that is then (ii) converted into electricity thanks to an electrostatic converter using electrets in Teflon ® . The semi-flexible and low-cost design of these new energy converters pave the way to mass production over large areas of thermal energy harvesters. Raw output powers up to 13.46 μW per device were reached on a hot source at 60 °C with forced convection. Then, a DC-to-DC flyback converter has been sized to turn the energy harvesters’ raw output powers into a viable supply source for an electronic circuit (DC-3 V). At the end, 10 μW of directly usable output power were reached with 3 devices, which is compatible with wireless sensor network powering applications. (paper)

  13. Long term and equilibrium factor indoor radon measurements

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Navarrete, M.; Cabrera, L.; Ramirez, A.; Elizarraras, V.

    1998-01-01

    This paper presents the annual radon gas concentrations obtained during the 1994-1995 monitoring campaign using passive electret system (type E-PERM). Radon levels were measured in 154 single family dwellings, in normal occupancy conditions (open house condition) in the metropolitan zone of Mexico City. At the same time radon monitoring was performed outdoors. The results show the general log-normal distribution of integrated indoor radon concentration with an annual indoor mean of 3.8 pCi x l -1 . The seasonal variations show the minimum mean values in the summer season which are 39% lower than that in autumn. Equilibrium factors (F) were measured in 12 typical houses both in autumn and winter using a continuous working level monitor for short-lived radon decay products and H-chamber loaded with a short term electret (HST, E-PERM) for radon gas. The obtained total mean equilibrium factors are: F=0.41±0.17 and F=0.29±0.04 for indoor and outdoor, respectively. A quality program was also improved. (author)

  14. Novel Particulate Air-Filtration Media: Market Survey

    Science.gov (United States)

    2013-02-01

    larger and more efficient filter designs similar to those being considered for future integrated respirator/helmet systems. To avoid eliminating ...including nonwoven, woven, and electret and combinations of media. Some of the manufacturers identified themselves as specializing in biofiltration or...Three Millipore products were identified. The 0.2 µm hydrophobic Aervent PTFE membrane62 is used for the sterile filtration of gases . Aerex

  15. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  16. Artificial Niches for Stromal Stem Cells as a Potential Instrument for the Design of the Surface of Biomimetic Osteogenic Materials

    Science.gov (United States)

    Khlusov, I. A.; Khlusova, M. Yu.; Pichugin, V. F.; Sharkeev, Yu. P.; Legostaeva, E. V.

    2014-02-01

    A relationship between the topography of rough calcium phosphate surfaces having osteogenic niche-reliefs and the electrostatic potential of these surfaces as a possible instrument to control stromal stem cells has been investigated. The in vitro culture of human lung prenatal stromal cells on nanostructured/ultrafine-grained VT1.0 titanium alloy plates with bilateral rough calcium phosphate (CaP) microarc coating was used. It was established that the amplitude of the electret CaP surface potential linearly increased with increasing area of valleys (sockets), and the negative charge is formed on the socket surface. The area of alkaline phosphatase staining (the marker of osteoblast maturation and differentiation) of adherent CD34- CD44+ cells increases linearly with increasing area of artificial microterritory (socket) of the CaP surface occupied with each cell. The negative electret potential in valleys (sockets) of microarc CaP coatings can be the physical mechanism mediating the influence of the surface topography on osteogenic maturation and differentiation of cells in vitro. This mechanism can be called "niche-potential" and can be used as an instrument for biomimetic modification of smooth CaP surfaces to strengthen their integration with the bone tissue.

  17. Procedures for and results of testing instruments for measuring radon in water

    International Nuclear Information System (INIS)

    Soukup, T.

    1998-01-01

    A measuring standard of radon dissolved in water was developed by the Inspectorate for Ionizing Radiation, Czech Metrological Institute, in 1995. The volume activity value is traceable to the national activity standard. The most frequent measuring procedures include Lukas chambers, spectrometric measurement of daughter products using NaI(Tl) detectors, electrets, liquid scintillators, ionization chambers, and Ge detectors. The results of comparison measurements match each other well

  18. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  19. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  20. Bio Organic-Semiconductor Field-Effect Transistor (BioFET) Based on Deoxyribonucleic Acid (DNA) Gate Dielectric

    Science.gov (United States)

    2010-03-31

    floating gate devices and metal-insulator-oxide-semiconductor (MIOS) devices. First attempts to use polarizable gate insulators in combination with...bulk of the semiconductor (ii) Due to the polarizable gate dielectric (iii) dipole polarization and (iv)electret effect due to mobile ions in the...characterization was carried out under an argon environment inside the glove box. An Agilent model E5273A with a two source-measurement unit instrument was

  1. Estimation of the radon dose in buildings by measuring the exhalation rate from building materials

    International Nuclear Information System (INIS)

    Steiner, V.; Kovler, K.; Perevalov, A.; Kelm, H.

    2004-01-01

    We review the accumulator technique using active (CRM) and passive detectors (activated charcoal and electret). We describe the ERS2 detector, an electrostatic radon sampler followed by alpha spectrometry, with improved algorithm and adapted to measure the exhalation rate from walls. The technique produces accurate results over a broad range of materials: concrete, Pumice, ceramics, tiles, granite, etc. The measured exhalation rate is the same, within errors, as measured by the standard detectors

  2. Development of diffusion-based radon daughter dosimeters

    International Nuclear Information System (INIS)

    Phillips, C.R.; Khan, A.; Leung, H.

    1983-07-01

    The objective of this work is to investigate the possible application of the mechanisms of thermophoresis and electrostatic collection via electrets to the collection of radon daughters with reference to personal alpha dosimeters for use in uranium mines. The potential advantage accruing from adoption of either one of these collection mechanisms is that collection is passive and does not depend upon the use of a pump (active), and is, therefore, intrinsically much more reliable

  3. Charging and switching of ferroelectrets: how much can ferroelectrets behave like ferroelectrics?

    International Nuclear Information System (INIS)

    Schwoediauer, R.; Graz, I.; Bauer, S.

    2004-01-01

    Dielectrics with good charge storage capability, so called charge electrets, are non or weakly-polar materials. Despite their non-polar nature porous charge electrets with internally charged surfaces can exhibit very pronounced piezoelectricity. Such systems have been termed 'ferroelectrets' and they have been receiving growing attention over the last few years. Their puzzling and unexpected features resemble very much those normally known from traditional ferroelectrics: ferroelectrets are piezo- and pyroelectric, their polarization can be reversed by means of an external field and electrical as well as mechanical hysteresis loops were observed. As conventional ferroelectrics are different and more complicated than ferromagnets, so are ferroelectrets different and more complex than most ferroelectrics. Here we report about the very different charging and switching mechanism in ferroelectrets, both in simple model-systems and in less simple foam structures. These mechanisms are crucial and form the basis for the striking phenomenological similarities to ferroelectrics. We also want to address some of the specific peculiarities and pitfalls related to present ferroelectrets and their characterization. Interfacial charge injection at high electric fields and anelastic non-linearities, for instance, can be the cause for false ferroelectric-like hysteresis effects which do not reflect any polarization reversal. Our contribution is an attempt towards a more comprehensive picture of how much ferroelectrets behave like ferroelectrics. (author)

  4. Porous polymer composite membrane based nanogenerator: A realization of self-powered wireless green energy source for smart electronics applications

    Science.gov (United States)

    Ghosh, Sujoy Kumar; Sinha, Tridib Kumar; Mahanty, Biswajit; Jana, Santanu; Mandal, Dipankar

    2016-11-01

    An efficient, flexible and unvaryingly porous polymer composite membrane based nanogenerator (PPCNG) without any electrical poling treatment has been realised as wireless green energy source to power up smart electronic gadgets. Owing to self-polarized piezo- and ferro-electretic phenomenon of in situ platinum nanoparticles (Pt-NPs) doped porous poly(vinylidenefluoride-co-hexafluoropropylene)-membrane, a simple, inexpensive and scalable PPCNG fabrication is highlighted. The molecular orientations of the -CH2/-CF2 dipoles that cause self-polarization phenomenon has been realized by angular dependent near edge X-ray absorption fine structure spectroscopy. The square-like hysteresis loop with giant remnant polarization, Pr ˜ 68 μC/cm2 and exceptionally high piezoelectric charge coefficient, d33 ˜ - 836 pC/N promises a best suited ferro- and piezo-electretic membrane. The PPCNG exhibits a high electrical throughput such as, ranging from 2.7 V to 23 V of open-circuit voltage (Voc) and 2.9 μA to 24.7 μA of short-circuit current (Isc) under 0.5 MPa to 4.3 MPa of imparted stress amplitude by periodic human finger motion. The harvested mechanical and subsequent electrical energy by PPCNG is shown to transfer wirelessly via visible and infrared transmitter-receiver systems, where 17% and 49% of wireless power transfer efficiency, respectively, has been realized to power up several consumer electronics.

  5. Typhoon and elevated radon level in a municipal water supply

    International Nuclear Information System (INIS)

    Mao, Cheng-Hsin; Weng, Pao-Shan

    2000-01-01

    The Municipal Water Supply at Hsinchu City is a water treatment plant using poly- aluminum chloride (PAC) for coagulation and then followed by precipitation and filtration. Its capacity is 70,000 m 3 /day. The raw water is drawn from the nearby river. Since the subject of interest is the radon level during typhoon season, the sampling period was from March to December 1999. Commercially available electret was used for water samples taken from the five ponds in the plant. This technique relies on the measurement of radon in air above a water sample enclosed in a sealed vessel. The concentration of airbone radon released from water was determined by means of the electret ion chamber. During the first sampling period there came two typhoons. One is called Magie during June 10-17, and the other called Sam during August 20-26. The first typhoon led to the radon level measured from the water samples as high as 705 Bq/m 3 , while the second caused even higher radon level as high as 772 Bq/m 3 . Similar results were obtained for the second sampling period after August till December 1999. For those measured without typhoon influence, the average radon was lower from the coagulation pond yet without coagulation process during March through August 1999. However, water samples taken from the pond after precipitation did not show similar results in radon level. (author)

  6. The 2008 intercomparison exercise for radon gas measurement instruments at PSI; Die Vergleichsmessung 2008 fuer Radongasmessgeraete am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2010-09-15

    Sixteen radon measurement services participated in the 2008 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) during August 28{sup th} to September 7{sup th}, 2008 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (etched-track, electronic and electret ionisation chambers) and instruments (ionization chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 627 Bq m{sup -3} leading to a radon gas exposure of 155 kBq h m{sup -3}. One measuring instrument participating for testing purposes stored values for part of the exposure interval (30.8. - 7.9.2008). The exposure during this partial interval was 117 kBq h m{sup -3} at an average radon gas concentration of 624 Bq m{sup -3}. The exposure of 155 kBq h m{sup -3} was the lowest used at the PSI intercomparisons down to the present day. Especially the LLT electret ionisation chambers used by some of the laboratories reached the lower end of their measurement range with this exposure. Unexpected deviations of instruments of the same model seem to show a dependence on the serial number and thus production date. (authors)

  7. A low-cost 3-D printed stethoscope connected to a smartphone.

    Science.gov (United States)

    Aguilera-Astudillo, Carlos; Chavez-Campos, Marx; Gonzalez-Suarez, Alan; Garcia-Cordero, Jose L

    2016-08-01

    We demonstrate the fabrication of a digital stethoscope using a 3D printer and commercial off-the-shelf electronics. A chestpiece consists of an electret microphone embedded into the drum of a 3D printed chestpiece. An electronic dongle amplifies the signal from the microphone and reduces any external noise. It also adjusts the signal to the voltages accepted by the smartphones headset jack. A graphical user interface programmed in Android displays the signals processed by the dongle. The application also saves the processed signal and sends it to a physician.

  8. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  9. Alpha-particle irradiation induced defects in SiO2 films of Si-SiO2 structures

    International Nuclear Information System (INIS)

    Koman, B.P.; Gal'chynskyy, O.V.; Kovalyuk, R.O.; Shkol'nyy, A.K.

    1996-01-01

    The aim of the work was to investigate alpha-particle irradiation induced defects in Si-SiO 2 structures by means of the thermostimulated discharge currents (TSDC) analysis. The object of investigation were (p-Si)-SiO 2 structures formed by a combined oxidation of the industrial p-Si wafers in dry and wet oxygen at temperature of 1150 C. The TSD currents were investigated in the temperature range between 90 and 500 K under linear heating rate. Pu 238 isotopes were the source of alpha-particles with an energy of 4-5 MeV and a density of 5.10 7 s -1 cm -2 . The TSD current curves show two peculiar maxima at about 370 and 480 K. Alpha-particle irradiation doesn't affect the general shape of the TSDC curves but leads to a shift of the maximum at 370 K and reduces the total electret charge which is accumulated in the Si-SiO 2 structures during polarization. The energy distribution function of the defects which are involved in SiO 2 polarization has been calculated. It showes that defects with activation energies of about 0.8 and 1.0 eV take part in forming the electret state, and these activation energies have certain energy distributions. It has been found that the TSDC maximum at 370 K has space charge nature and is caused by migration of hydrogen ions. In irradiated samples hydrogen and natrium ions localize on deeper trapping centres induced by alpha-particle irradiation. (orig.)

  10. Exposure of tour guides to Radon at the Cango caves

    International Nuclear Information System (INIS)

    Pule, O.J.; Lindsay, R.

    2008-01-01

    Full text: A study was commissioned by the National Nuclear Regulator of South Africa to investigate the radon levels in the Cango caves and the associated radiological exposure to tour guides. The Cango caves are about 1.3 km in length and are visited by about 300000 tourists per annum due to their natural beauty. This study followed an earlier investigation by the Department of Health which indicated levels in excess of 1000 Bqm -3 which could lead to excess exposure of the cave tour guides. Radon in the various cave chambers and radon exposure of tour guides was measured using RAD-7 continuous radon monitor, electrets ion chambers and personnel monitoring electrets respectively. The measurements in the cave were done during summer and winter seasons to determine any variations between the seasons. The occupancy time for individual guides and equilibrium factor were also investigated. The radon concentration in the cave range from 1000 Bqm -3 to more than 2000 Bqm -3 with equilibrium factor of approximately 0.4, and the variation between winter and summer measurements are insignificant. The radon exposure levels to tour guides differ due to various time periods they spent in the caves. The average dose to tour guides due to radon is 7 mSv -a and the highest exposure is about 10 mSv -a . The exposure to tourists is found to be insignificant due to time they spent in the cave. The regulatory authority is currently investigating what action is necessary to protect the tour guides. (author)

  11. Bio-assembled nanocomposites in conch shells exhibit giant electret hysteresis

    KAUST Repository

    Yao, Yingbang

    2012-10-23

    Giant electric polarization (2000-4000 μC cm-2) is observed in natural conch shells. The nanolaminas and biopolymer layers of their unique hierarchical microstructures exhibit ferroelectret behavior and account for the observed polarization. Such huge polarization leads to extremely high pyroelectric coefficients, 2-3 orders of magnitude larger than those of conventional ferroelectric materials. The possibility of tailoring the giant polarization for various applications is considered. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Bio-assembled nanocomposites in conch shells exhibit giant electret hysteresis

    KAUST Repository

    Yao, Yingbang; Wang, Qingxiao; Wang, Hongtao; Zhang, Bei; Zhao, Chao; Wang, Zhihong; Xu, Zhengkui; Wu, Ying; Huang, Wei; Qian, Peiyuan; Zhang, Xixiang

    2012-01-01

    Giant electric polarization (2000-4000 μC cm-2) is observed in natural conch shells. The nanolaminas and biopolymer layers of their unique hierarchical microstructures exhibit ferroelectret behavior and account for the observed polarization. Such huge polarization leads to extremely high pyroelectric coefficients, 2-3 orders of magnitude larger than those of conventional ferroelectric materials. The possibility of tailoring the giant polarization for various applications is considered. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Monitoring of urban particulate using an electret-based passive sampler

    Energy Technology Data Exchange (ETDEWEB)

    Thorpe, A.; Hemingway, M.A.; Brown, R.C.

    1999-11-01

    Site sampling trials have been carried out in the urban environment in order to assess the usefulness of a passive sampling device, originally developed for personal monitoring of airborne dust levels in industry. The sampling element is a small disc of elect material (polymer carrying a permanent electric charge) within a metal frame weighing approximately 15 g. The sampler is designed to capture particles by electrostatic attraction, in which case the capture rate depends on their electrical mobility but is independent of the rate at which air flows past the device. Passive samplers, along with miniaturized cascade impactors, have been exposed to urban particulate for periods of up to 28 days in locations with significant different levels of airborne pollution. The cascade impactor data enabled good estimates to be made of PM{sub 10} and PMN{sub 2.5} levels, and data from the passive sampler correlated with the total dust sampled by the impactor and with both the size fractions, that with the PM{sub 10} being better. Too few data have yet been obtained for its accuracy to be established, but it is unlikely that it will approach that of pumped samplers. It has been shown to be potentially useful for multiple, simultaneous site sampling and for monitoring personal environmental exposure situations in which dispensing with a power source is particularly useful. Being small, the sampler is easy to hide or camouflage, and because it is cheap, its loss or damage is not a serious matter.

  14. Indoor radon concentrations and radon doses at three districts of Ankara, Turkey and raising public awareness on the issue

    International Nuclear Information System (INIS)

    Mehmet Kildir; Inci Goekmen; Ali Goekmen

    2016-01-01

    Indoor radon concentrations at METU, CIGDEM and DOSTLAR in Ankara were measured using electrets. The statistical analysis of the data indicated a lognormal distribution of radon concentrations, with no significant difference between CIGDEM and DOSTLAR with geometric means of GM = 87.5 and 54.5 Bq m -3 , respectively. Radon concentrations did not change seasonally at CIGDEM which contain modern buildings, but at the slum district DOSTLAR, with poor insulation of houses a seasonal variation was observed. Annual effective radon doses were estimated (0.4-8.4 mSv). Public awareness about indoor radon was raised. (author)

  15. Continuous and passive environmental radon monitoring: Measuring methods and health effects. (Latest citations from the INSPEC: Information services for the Physics and Engineering Communities database). Published Search

    International Nuclear Information System (INIS)

    1993-08-01

    The bibliography contains citations concerning continuous and passive radon (Rn) monitoring, measurement methods and equipment, and health effects from Rn concentration in air, water, and soils. Citations discuss the design, development, and evaluation of monitoring and detection devices, including alpha spectroscopy and dosimetry, track detecting and scintillation, thermoluminescent, electret, and electrode collection. Sources of Rn concentration levels found in building materials, ventilation systems, soils, and ground water are examined. Lung cancer-associated risks from Rn radiation exposure are explored. Radon monitoring in mining operations is excluded. (Contains a minimum of 210 citations and includes a subject term index and title list.)

  16. Trace gas sensing using quantum cascade lasers and a fiber-coupled optoacoustic sensor: Application to formaldehyde

    Energy Technology Data Exchange (ETDEWEB)

    Elia, A; Lugara, P M; Scamarcio, G [CNR-INFM Regional Laboratory LIT and Dipartimento Interateneo di Fisica, Universita di Bari, via Amendola 173, 70126 Bari (Italy); Spagnolo, V [CNR-INFM Regional Laboratory LIT and Dipartimento Interateneo di Fisica, Politecnico di Bari, via Amendola 173, 70126 Bari (Italy); Di Franco, C, E-mail: spagnolo@fisica.uniba.i [CNR-INFM Regional Laboratory LIT, via Amendola 173, 70126 Bari (Italy)

    2010-03-01

    We will report here on the design and realization of an optoacoustic sensor for the detection of formaldehyde. The sensor consists of a commercial QCL and a resonant PA cell. Two different cell configurations have been investigated: a 'standard' H cell and an innovative T-cell with an optical fiber directly inserted into. Two different type of sound detector have been employed: electret microphones and optical MEMS-based microphone. As possible applications, we will describe the results obtained in the detection of formaldehyde (CH{sub 2}O), a gas of great interest for industrial processes and environmental monitoring.

  17. Development of instrumentation in nuclear geophysics and their use in Morro do Ferro

    International Nuclear Information System (INIS)

    Hiodo, F.Y.

    1989-01-01

    The development of nuclear detection and stabilization circuits was described. Furthermore, gamma and alpha spectrometry methodologies were developed for field and laboratory measurements. By the use of techniques from other geophysical instruments as fluxgate and optical pumping magnetometers, it was possible to develop stabilization and linearization circuits for gamma ray spectrometers composed by scintillation crystals and multichannel analyzers. The developed system presents excellent thermal and temporal stability, leading to a high reproducibility of the measurements. Teflon PTFE electrets based ionization chambers were constructed for monitoring the alpha particles from soil emanated radon, from the uranium and thorium radioactive series. (author)

  18. Soil radon pulses related to the initial phase of volcanic eruptions

    International Nuclear Information System (INIS)

    Segovia, N.; Mena, M.

    1999-01-01

    Soil radon behaviour related to the initial phase of volcanic eruptions is analysed from reported values related to the explosivity of four American stratovolcaneos: El Chicon (1982) and Popocatepetl (1994) in Mexico, Poas (1987-1990) in Costa Rica and Cerro Negro (1982) in Nicaragua. The measurements in the field were performed with solid-state nuclear track detectors and electrets. The ratio between the magnitudes of the radon in soil peaks generated when the eruptive period started and the average radon values corresponding to quiescence periods indicate a dependence on the volcanic eruptive index for each one of the eruptive periods

  19. A MEMS Energy Harvesting Device for Vibration with Low Acceleration

    DEFF Research Database (Denmark)

    Triches, Marco; Wang, Fei; Crovetto, Andrea

    2012-01-01

    We propose a polymer electret based energy harvesting device in order to extract energy from vibration sources with low acceleration. With MEMS technology, a silicon structure is fabricated which can resonate in 2D directions. Thanks to the excellent mechanical properties of the silicon material......, the proof mass could be successfully driven by an external vibrations with acceleration as low as 0.014g (∼0.14 m/s2). A root mean square (RMS) power output of 1.17μW under 0.014g RMS acceleration at 75Hz is measured when an optimal load of 20.3 MΩ is applied. The frequency response of the device is also...

  20. Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas

    Directory of Open Access Journals (Sweden)

    Pietro Mario Lugarà

    2009-04-01

    Full Text Available We report on the development of a photoacoustic sensor for the detection of formaldehyde (CH2O using a thermoelectrically cooled distributed-feedback quantum cascade laser operating in pulsed mode at 5.6 mm. A resonant photoacoustic cell, equipped with four electret microphones, is excited in its first longitudinal mode at 1,380 Hz. The absorption line at 1,778.9 cm-1 is selected for CH2O detection. A detection limit of 150 parts per billion in volume in nitrogen is achieved using a 10 seconds time constant and 4 mW laser power. Measurements in ambient air will require water vapour filters.

  1. Methods of radon measurement and devices

    International Nuclear Information System (INIS)

    Miles, J.

    2004-01-01

    The following topics and instrumentation are discussed: The quantity to be measured; Active measurement methods (scintillation cells, ionisation chambers, electrostatic collection of decay products); Passive measurement methods (charcoal detectors; electret ion chambers; etched track detectors); and Detector considerations for large-scale surveys ('always on' or 'switchable' detectors?; response to radon-220; avoidance of electrostatic effects; quality assurance for passive radon detectors; quality control within the laboratory; external quality assurance; detectors need to be easily deliverable). It is concluded that the ideal detector for large scale surveys of radon in houses is a small, closed detector in a conducting holder which excludes radon-220, supported by rigorous quality assurance procedures. (P.A.)

  2. Electron-beam induced conduction in some polymers

    International Nuclear Information System (INIS)

    Suzuoki, Yasuo; Mizutani, Teruyoshi; Ieda, Masayuki

    1976-01-01

    The charge signal induced by pulsed electron beam consists of two components, i.e. the fast and the slow components. The slow component which corresponds to carrier transport via shallow traps exhibited an asymmetry with respect to the bias field polarity. The asymmetry revealed that the main carriers which drifted via shallow traps were electrons in PET, both electrons and holes in PEN, and holes in PS. TSC spectra of electron-beam induced electrets proved directly the existence of electron shallow traps in PET and both electron and hole traps in PEN. Their trap energies were 0.1 to 0.2 eV. (auth.)

  3. Nanomechanical and electrical characterization of a new cellular electret sensor-actuator

    International Nuclear Information System (INIS)

    Windmill, J F C; Zorab, A; Bedwell, D J; Robert, D

    2008-01-01

    Electrically charged cellular polymers are known to display pseudo-piezoelectric effects that endow them with interesting mechano-electrical characteristics. When a film of such a polymer is compressed, charge is generated across its thickness, and conversely, applying an oscillatory or static potential elicits mechanical motions. This dual sensor-actuator behaviour can be embedded in one material and presents distinct advantages of functional integration. A novel electroactive foam is presented here that embeds such a sensor-actuator function. The foam has a sensitivity constant (d 33 ) of 330 pC N -1 . Interestingly, the resonant behaviour of the cellular film can be altered by variation in the DC offset across the material. Such adaptive capacity could be of great advantage for tuning polymer-based mechanical devices to be either efficient sound radiators and mechanical actuators, or sensitive and coherent sensors. Possible applications in microfluidics are also discussed

  4. Development of digital stethoscope for telemedicine.

    Science.gov (United States)

    Lakhe, Aparna; Sodhi, Isha; Warrier, Jyothi; Sinha, Vineet

    2016-01-01

    The stethoscope is a medical acoustic device which is used to auscultate internal body sounds, mainly the heart and lungs. A digital stethoscope overcomes the limitations of a conventional stethoscope as the sound data is transformed into electrical signals which can be amplified, stored, replayed and, more importantly, sent for an expert opinion, making it very useful in telemedicine. With the above in view, a low cost digital stethoscope has been developed which is interfaceble with mobile communication devices. In this instrument sounds from various locations can be captured with the help of an electret condenser microphone. Captured sound is filtered, amplified and processed digitally using an adaptive line enhancement technique to obtain audible and distinct heart sounds.

  5. Radon diagnostics and mitigation in two public schools in Nashville, Tennessee

    International Nuclear Information System (INIS)

    Craig, A.B.; Leovic, K.W.; Harris, D.B.

    1990-01-01

    This paper reports on diagnostic measurements and mitigation studies that were carried out in two schools in Nashville, Tennessee, as part of the Environmental Protection Agency's (EPAs) School Radon Mitigation Development/Demonstration Program. Diagnostic studies included architectural plans and building examination, sub-slab radon concentrations, sub-slab communications measurements, and detailed classroom radon measurements using 2-day charcoal canisters, electret ion chambers, and continuous monitors. Although sub-slab communications varied significantly between the two schools, both were amenable to mitigation using sub-slab suction. Average premitigation levels of 39.5 and 29.7 picocuries per liter (pCi/L) were reduced to 0.78 and 1.7 pCi/L in the two schools

  6. Radon determination by activated charcoal adsorption and liquid scintillation measurement

    International Nuclear Information System (INIS)

    Lopez, F.O.; Canoba, A.C.

    1998-01-01

    A passive diffusion method for the determination of radon concentration has been optimised and calibrated. The device consists of a scintillation vial containing activated charcoal, a diffusion barrier and a desiccant agent. The response to diverse atmospheric humidity and variable exposure intervals was studied. The result is a detector, which is independent of atmospheric humidity for at least (up to) 7 days of exposure. The method was compared with electret detectors (US EPA) with very satisfactory results. The advantages of this method are its simplicity, low cost, low detection limit, the total automatization of the measurement and its total independence of humidity to measure in a wide range of radon concentrations. (author) [es

  7. Raman spectroscopy and dielectric Studies of multiple phase transitions in ZnO:Ni

    Science.gov (United States)

    Yadav, Harish Kumar; Sreenivas, K.; Gupta, Vinay; Scott, J. F.; Katiyar, R. S.

    2008-03-01

    We present Raman and dielectric data on Ni-doped ZnO (Zn1-xNixO) ceramics as a function of Ni concentration (x =0.03, 0.06, and 0.10) and temperature. A mode (around 130cm-1) is identified as TA(M) [J. M. Calleja and M. Cardona, Phys. Rev. B 16, 3753 (1977)] and appears due to an antiferromagnetic phase transition at low temperatures (100K) via the spin-orbit mechanism [P. Moch and C. Dugautier, Phys. Lett. A 43, 169 (1973)]. A strong dielectric anomaly occurs at around 430-460K, depending on Ni concentration, and is due to extrinsic electret effects (Ni ionic conduction) and not to a ferroelectric phase transition.

  8. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  9. Elastic wave excitation in centrosymmetric strontium titanate crystals

    International Nuclear Information System (INIS)

    Yushin, N.K.; Sotnikov, A.V.

    1980-01-01

    The main experimental dependencies are measured and the excitation mechanism of elastic waves in centrosymmetric crystals is established. The surface generation of three-dimensional elastic waves of the 30 MHz frequency in strontium titanate crystals is observed and studied. Elastic wave excitation is observed in the 4 350 K temperature range. The efficiency of hysteresis excitation depends on the external electric field. The effect of light irradiation on the amplitude of excited elastic waves is observed. It is shown that escitation is connected with linearization of electrostriction by the constant electric field appearing in a near-surface crystal layer due to phenomena in the Schottky barrier and appearance of electretic near-electrode layers

  10. The electret detector for ionizing radiations: no energy consumption in watching state

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This very simple and cheap detector measures doses absorbed by the user who can control it at any time. Its main advantage is the capability of acting an alarm signal or any other security device when the maximum permissible dose is overrun [fr

  11. Benefits of the Fiber Optic versus the Electret Microphone in Voice Amplification

    Science.gov (United States)

    Kyriakou, Kyriaki; Fisher, Helene R.

    2013-01-01

    Background: Voice disorders that result in reduced loudness may cause difficulty in communicating, socializing and participating in occupational activities. Amplification is often recommended in order to facilitate functional communication, reduce vocal load and avoid developing maladaptive compensatory behaviours. The most common microphone used…

  12. Electrostatic nanopatterning of PMMA by AFM charge writing for directed nano-assembly

    International Nuclear Information System (INIS)

    Ressier, L; Nader, V Le

    2008-01-01

    Electrostatic nanopatterning of poly(methylmethacrylate) (PMMA) thin films by atomic force microscopy (AFM) charge writing was investigated using Kelvin force microscopy (KFM). The lateral size of the electrostatic patterns and the amount of injected charges are closely correlated and can be controlled by the height of the voltage pulses applied to the AFM tip and the tip-sample separation during the writing process. Charge retention measurements show that PMMA has excellent charge storage properties in air under relative humidities from 1% to 60% and withstands immersion in ultra-pure water. This study thus reveals that PMMA is a very promising electret to create efficient electrostatic nanopatterns for directed self-assembly of nanoscale objects, including the broad range of colloidal particles or molecules in aqueous solutions

  13. Data Acquisition and Digital Filtering for Infrasonic Records on Active Volcanoes

    Directory of Open Access Journals (Sweden)

    José Chilo

    2007-03-01

    Full Text Available This paper presents the design of a digital data acquisition system for volcanic infrasound records. The system includes four electret condenser element microphones, a QF4A512 programmable signal converter from Quickfilter Technologies and a MSP430 microcontroller from Texas Instruments. The signal output of every microphone is converted to digital via a 16-bit Analog to Digital Converter (ADC. To prevent errors in the conversion process, Anti-Aliasing Filters are employed prior to the ADC. Digital filtering is performed after the ADC using a Digital Signal Processor, which is implemented on the QF4A512. The four digital signals are summed to get only one signal. Data storing and digital wireless data transmission will be described in a future paper.

  14. Gamma, radon, natural radioactivity measurements in Chile

    International Nuclear Information System (INIS)

    Stuardo, E.

    1997-01-01

    Different natural radiation measurements, performed since 1983, are analysed and discussed regarding the average effective population dose. A decade of absorbed gamma dose measurements in air (1983-93), were carried out using compensated TLD detectors, during long periods of integration time and with a network of 11 stations, along the country, from Arica to the Antarctic territory. An indoor Rn -222 and gamma survey dwellings, in high background zones, underground mines and drinking water was started in 1988 using different kind of detectors, including electret radon chambers. The methods, dose assessments and results are presented and discussed in the frame of worldwide average effective population doses. None of the average effective doses found over the evaluated areas, exceed the comparison levels. (author)

  15. Ultralow frequency bridge for dielectric measurements: applications to electrects

    International Nuclear Information System (INIS)

    Slaets, J.

    1976-01-01

    The problem of U.L.F. (Ultra Low Frequency) dielectric relaxation is investigated. An experimental model is proposed for a bridge covering the range of 10 -3 Hz-10Hz, pased on phase shift measurements originally proposed by Van Turhout and collaborators. The main experimental problems are also analyzed with such U.L.F. measurements and describe its construction and performance. The theoretical correlation between U.L.F. dielectric relaxation and electret thermal stimulated currents is also investigated. A correction for the integral expression given by Turnhout and collaborators, is calculated in particular that takes into account the value of the activation energy in the relation between the two techniques.The correction is important for values of the activation energy below 0,5eV, which occur frequently in dielectric relaxation processes. (Author) [pt

  16. The Effect of Radiation "Memory" in Alkali-Halide Crystals

    Science.gov (United States)

    Korovkin, M. V.; Sal'nikov, V. N.

    2017-01-01

    The exposure of the alkali-halide crystals to ionizing radiation leads to the destruction of their structure, the emergence of radiation defects, and the formation of the electron and hole color centers. Destruction of the color centers upon heating is accompanied by the crystal bleaching, luminescence, and radio-frequency electromagnetic emission (REME). After complete thermal bleaching of the crystal, radiation defects are not completely annealed, as the electrons and holes released from the color centers by heating leave charged and locally uncompensated defects. Clusters of these "pre centers" lead to electric microheterogeneity of the crystal, the formation of a quasi-electret state, and the emergence of micro-discharges accompanied by radio emission. The generation of REME associated with residual defectiveness, is a manifestation of the effect of radiation "memory" in dielectrics.

  17. Extreme Low Frequency Acoustic Measurement System

    Science.gov (United States)

    Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)

    2017-01-01

    The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

  18. Radon gas measurements inside houses of the Argentine Republic

    International Nuclear Information System (INIS)

    Canoba, Analia C.; Arnaud, Marta I.; Lopez, Fabio O.; Oliveira, Antonio

    2001-01-01

    Indoor radon gas concentrations were measured in dwellings in various cities of Argentina. Solid-state nuclear track, electrets and activated charcoal detectors were the methods used for monitoring the radon concentration.A total of 2034 homes were monitored since the beginning of this project in 1983. The monitored homes are constructed of a variety of building materials but most of them are built predominantly of bricks and concrete. The mean values calculated for the different cities are below 50 Bq m -3 . Very few values above 200 Bq m -3 were found and none exceeded 300 Bq m -3 . The mean value for the whole country is 34.6 Bq m -3 with a geometric mean of 25.0 Bq m -3 and the corresponding annual effective dose is 0.86 mSv. (author)

  19. Measurements of radon gas in dwellings of Argentina

    International Nuclear Information System (INIS)

    Canoba, A.C.; Arnaud, M.I.; Lopez, F.O.; Oliveira, A.A.

    1998-01-01

    The concentration of radon gas in dwellings of several cities of Argentina was measured. For this purpose, different kind of detectors were used such as passive solid state nuclear track detectors, electrets and detectors which use activated charcoal. Since 1983, a total of 1630 dwellings were analysed. The cases monitored were dwellings where the main construction materials are reinforced concrete and brick. The average values found in each city are below 50 Bq/m 3 . The values above 200-Bqm 3 are very few, and none of them is above 300 Bq/m 3 . The average value of radon gas in air dwellings in our country is 33 Bq/m 3 , with a geometric mean of 23 Bq/m 3 , corresponding to an annual effective dose of 0.83 mSv. (author) [es

  20. Measurement protocol for radon measurements in workplaces above ground

    International Nuclear Information System (INIS)

    Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    The Swedish Radiation Protection Authority, SSI, has established a measurement protocol for measurements of radon in workplaces. The result from a measurement according to the protocol can be compared to the limit for indoor radon at workplaces, 400 Bq/m 3 issued by the Swedish Work Environment Authority and also to the action level for schools, preschools and public buildings, 400 Bq/m 3 , issued by the National Board of Health and Welfare. The protocol recommends measurements to be done in two steps. The first measurement, called the preliminary measurement, will be done with an integrating measurement method over a period of at least two months. Track etch detectors or electret devices can be used. Since the preliminary measurements often overestimates the radon levels the workers are actually exposed to during working hours, a follow-up measurement has to be done if the preliminary measurement gives a result that exceeds 400 Bq/m 3 . In case there is need for an annual mean for comparison to the action level for schools a long-term measurement has to be done. Otherwise a method for follow-up measurements can be used at once. The follow-up measurement has to show the radon level during working hours. Two measurement strategies can be used depending on the function of the ventilation system. With the ventilation system running constantly, measurements can be done with track etch detectors for ten days or electret devices for five days. If the ventilation system is closed down at night electrets can be used for five days if the devise is open only during working hours or a continuous measurement device can be used for two days. Measurements have to be performed during the heating season, i.e. when the 24-hour average temperature is below +10 deg C, usually between October 1 and April 31. Most importantly the difference between interior and exterior temperatures must be big enough to allow natural draught ventilation system to activate. The result from a

  1. Slip-stick excitation and travelling waves excite silo honking

    Science.gov (United States)

    Warburton, Katarzyna; Porte, Elze; Vriend, Nathalie

    2017-06-01

    Silo honking is the harmonic sound generated by the discharge of a silo filled with a granular material. In industrial storage silos, the acoustic emission during discharge of PET-particles forms a nuisance for the environment and may ultimately result in structural failure. This work investigates the phenomenon experimentally using a laboratory-scale silo, and successfully correlates the frequency of the emitted sound with the periodicity of the mechanical motion of the grains. The key driver is the slip-stick interaction between the wall and the particles, characterized as a wave moving upwards through the silo. A quantitative correlation is established for the first time between the frequency of the sound, measured with an electret microphone, and the slip-frequency, measured with a high-speed camera. In the lower regions of the tube, both the slip-stick motion and the honking sound disappear.

  2. Relationship between short and long term radon measurements

    International Nuclear Information System (INIS)

    Martinez, T.; Ramirez, D.; Navarrete, M.; Cabrera, L.; Ramirez, A.; Gonzalez, P.

    2000-01-01

    In this work the radon group of the Faculty of Chemistry at the National University of Mexico presents the results obtained in the establishment of a relation between the short and long term radon measures made with passive electret detectors E-PERM type LLT and HST. The measures were carried out inside single family dwellings (open house condition) located in the southeast of Mexico City (in Xochimilco) during the four seasons of the year 1997. A correlation was established between the short term measures (five days) and those of a long term for every season as well as an annual average, with an equation that relates them. The objective and advantage of this correlation are that with a short term measure it is possible to predict the annual mean radon concentration, that represents a saving of human and economic resources. (author)

  3. Intercomparison of radon gas detectors 1997 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck-Dempewolf, Gernot

    1998-05-01

    Between Nov 14 and Nov 20, 1997, the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut performed the 1997 Radon Intercomparison Exercise. Radon gas detectors and instruments were exposed in the PSI Radon Chamber during seven days in a reference atmosphere with an average radon gas concentration of 3860 Bqm -3 . The majority of the participants at this intercomparison were Swiss Radon Gas Measurement Laboratories acknowledged by the Swiss Federal Office for Health. Criteria for this acknowledgement are a deviation of the measurement results to the reference value below 15% (traceability criterion) and a standard deviation of the mean of five detector measurement results below 15% (reproducibility criterion). With the exception of three participants, the results of electret ionisation chambers, track etch detectors and measuring instruments fulfilled the demanded traceability and reproducibility criteria. (author)

  4. Electrostatic energy harvesting device with out-of-the-plane gap closing scheme

    DEFF Research Database (Denmark)

    Wang, Fei; Hansen, Ole

    2014-01-01

    In this paper, we report on an electrostatic energy harvester with an out-of-the-plane gap closing scheme. Using advanced MEMS technology, energy harvesting devices formed by a four wafer stack are batch fabricated and fully packaged at wafer scale. A spin coated CYTOP polymer is used both...... as an electret material and an adhesive layer for low temperature wafer bonding. The overall size of the device is about 1.1 cm × 1.3 cm. At an external load resistance of 13.4 MΩ, a power output of 0.15 μW is achieved when vibration at an acceleration amplitude of 1 g (∼9.8 m/s2) is applied at a low frequency...... of 96 Hz. The frequency response of the device is also measured and a broader bandwidth is observed at higher acceleration amplitude....

  5. Electrostatic energy harvesting device with out-of-the-plane gap closing scheme

    DEFF Research Database (Denmark)

    Wang, Fei; Hansen, Ole

    2013-01-01

    In this paper, we report on an electrostatic energy harvester with an out-of-the-plane gap closing scheme. Using advanced MEMS technology, energy harvesting devices with a four wafer stack are batch fabricated and fully packaged at wafer scale. CYTOP polymer is used both as an electret material...... and an adhesive layer for low temperature wafer bonding. The overall size of the device is about 1.1×1.3 cm2. With an external load of 13.4 MΩ, a power output of 0.15 μW is achieved when vibration at an acceleration amplitude of 1 g (9.8 m/s2) is applied at a low frequency of 96 Hz. The frequency response...... of the device is also measured and a broader bandwidth is observed at higher acceleration amplitude. © 2013 IEEE....

  6. The 1996 Radon Intercomparison Exercise at PSI

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.

    1997-05-01

    The 1996 Radon Intercomparison Exercise at PSI was organized by the PSI Reference Laboratory for Radon Gas Activity Concentration Measurements. A total of 14 laboratories, companies and institutions participated with radon gas detectors and measuring instruments. The detectors and instruments were exposed in the PSI radon chamber during seven days in a reference atmosphere with an average radon gas concentration of about 6000 Bqm -3 . Comparison of the results of electret ionization chambers, track etch detectors and measuring instruments with the PSI target value showed the criteria for traceability and reproducibility demanded by the Federal Office for Health for the acknowledgement of Swiss Radon Gas Measurement Laboratories to be fulfilled for all participants. Exposure of track etch detectors stored for more than one year demonstrated that this detector type can suffer sensitivity loss by a too long storage period. (author) figs., tabs., refs

  7. Direct determination of 222Rn gas using the electret to remove daughters at formation

    International Nuclear Information System (INIS)

    Harley, N.H.

    1981-01-01

    Five compact, portable, continuous 222 Rn monitors have been constructed inhouse. Printed data can be obtained from intervals ranging from 10 minutes to 990 minutes. One hour count interval provides a lower limit of detection of 0.03 pCi 222 Rn/l -1 which is sufficient for measurement of any environmental level encountered. Calibration of the units was accomplished in the EML radon calibration room and the typical calibration factor is 165 counts per hour per pCi 222 Rn/l. The units are now being field tested. Two indoor/outdoor pairs are located in a single family dwelling and in a high rise apartment. One unit is being used for special studies

  8. Slip-stick excitation and travelling waves excite silo honking

    Directory of Open Access Journals (Sweden)

    Warburton Katarzyna

    2017-01-01

    Full Text Available Silo honking is the harmonic sound generated by the discharge of a silo filled with a granular material. In industrial storage silos, the acoustic emission during discharge of PET-particles forms a nuisance for the environment and may ultimately result in structural failure. This work investigates the phenomenon experimentally using a laboratory-scale silo, and successfully correlates the frequency of the emitted sound with the periodicity of the mechanical motion of the grains. The key driver is the slip-stick interaction between the wall and the particles, characterized as a wave moving upwards through the silo. A quantitative correlation is established for the first time between the frequency of the sound, measured with an electret microphone, and the slip-frequency, measured with a high-speed camera. In the lower regions of the tube, both the slip-stick motion and the honking sound disappear.

  9. Field demonstrations of passive detectors for screening of alpha contaminated soils

    International Nuclear Information System (INIS)

    Meyer, K.E.; Gammage, R.B.; Dudney, C.S.

    1994-01-01

    There are numerous sites around the country, DOE and otherwise, that are faced with the daunting task of remediating radiologically contaminated soils and groundwaters. Some of these sites, such as the Nevada Test Site and the Rocky Flats Plant, have contaminants that have been dispersed over wide areas. The costs of the characterization phase alone for such remediation programs can be prohibitive. Therefore there are pressing needs for testing and evaluation of new technologies for screening for radiological contaminants that may offer significant advantages in capital costs, ease of use, sensitivity, ruggedness, and/or reliability. This work reports on laboratory and Field tests of two types of passive alpha detectors, electret ionization chambers (EIC's) and alpha track detectors (ATD's), that have been commercially developed for indoor radon measurements. Previous work documented calibration and measurement protocols developed for these detectors for indoor surface contamination measurements

  10. One cubic metre NIST traceable radon test chamber

    International Nuclear Information System (INIS)

    Kotrappa, P.; Stieff, F.

    2008-01-01

    With the availability of the National Inst. of Standards and Technology (NIST) Radon Emanation Standard with a content of ∼5000 Bq of 226 Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a flow integrator, water jar for humidification and NIST source holder, and into the glove box through a manifold. A derived theoretical expression provides the calculated radon concentration inside the chamber. The calculation includes a derived decay correction due to the large volume and low flow rate of the system. Several calibrated continuous radon monitors and passive integrating electret ion chambers tested in the chamber agreed fairly well with the calculated radon concentrations. The chamber is suitable for handling the calibration of several detectors at the same time. (authors)

  11. Thermal and optical properties of polycrystalline CdS thin films deposited by the gradient recrystallization and growth (GREG) technique using photoacoustic methods

    International Nuclear Information System (INIS)

    Albor-Aguilera, M.L.; Gonzalez-Trujillo, M.A.; Cruz-Orea, A.; Tufino-Velazquez, M.

    2009-01-01

    In this work we report the study of the thermal and optical properties of polycrystalline CdS thin films deposited by the gradient recrystallization and growth technique. CdS films were grown on pyrex glass substrates. These studies were carried out using an open photoacoustic cell made out of an electret microphone. From X-ray diffraction, atomic force microscope and photoluminescence measurements we observed polycrystalline CdS films with good morphology and crystalline quality. We obtained a thermal diffusivity coefficient of our samples with values ranging from 3.15 to 3.89 x 10 -2 cm 2 /s. For comparison, we measured a value of 1.0 x 10 -2 cm 2 /s for the thermal diffusivity coefficient of a CdS single crystal. We measured an energy gap value of 2.42 eV for our samples by using a photoacoustic spectroscopy system

  12. Dielectric and polarization behaviour of cellulose electro-active paper (EAPap)

    International Nuclear Information System (INIS)

    Yun, Gyu-Young; Kim, Joo-Hyung; Kim, Jaehwan

    2009-01-01

    Dielectric and polarization behaviour of electro-active paper (EAPap) were studied to understand the detailed material behaviour of EAPap as a novel smart material. It was revealed that the dielectric constant of EAPap was temperature and frequency dependent. The largest change in the dielectric constant was observed near 0 0 C while the highest dielectric constant was obtained at around 100 0 C, which might be related to the dipolar behaviour of the hydroxyl structure of cellulose and adsorbed or existing internal water molecules in cellulose EAPap. By thermal stimulated current measurement for polarization behaviour of cellulose EAPap, it was shown that the maximum current was observed in the temperature range 105-110 0 C. Compared with the polarization behaviour in the low temperature range, abnormal polarization was observed under an applied field mainly due to the trapped space charge in EAPap, which indicates that cellulose EAPap has a similar material behaviour to that of electret polymers. (fast track communication)

  13. Indoor radon levels in Riyadh city dwellings

    International Nuclear Information System (INIS)

    Alghamdi, Abdulrahman S.; Khalid, Aleissa; Ghazi, Alzeer

    2008-01-01

    Full text: Building materials used for construction of houses represent a major source of indoor radon. In this investigation, indoor radon concentrations are found to vary substantially among the different building materials, ventilation, cooling and heating systems used. This paper presents the effects of these factors on the radon concentration in Riyadh city dwellings. The measurements were obtained by using a passive integrating ionization system with an E-Perm Electret ion chamber. The study covered more than 700 houses and apartments, which were selected to cover the most common type of houses. The concentration range was found to be 1.02 to 196 Bq.m -3 , with an average value of 17.5 ± 3 Bq.m -3 . The results show that the radon concentration is higher in houses where the white bricks, no ventilation systems, plastic paint and Freon air conditioners are used, but relatively lower in houses where the red bricks, window ventilation, and water air conditioner is used. (author)

  14. Software development for the analysis of heartbeat sounds with LabVIEW in diagnosis of cardiovascular disease.

    Science.gov (United States)

    Topal, Taner; Polat, Hüseyin; Güler, Inan

    2008-10-01

    In this paper, a time-frequency spectral analysis software (Heart Sound Analyzer) for the computer-aided analysis of cardiac sounds has been developed with LabVIEW. Software modules reveal important information for cardiovascular disorders, it can also assist to general physicians to come up with more accurate and reliable diagnosis at early stages. Heart sound analyzer (HSA) software can overcome the deficiency of expert doctors and help them in rural as well as urban clinics and hospitals. HSA has two main blocks: data acquisition and preprocessing, time-frequency spectral analyses. The heart sounds are first acquired using a modified stethoscope which has an electret microphone in it. Then, the signals are analysed using the time-frequency/scale spectral analysis techniques such as STFT, Wigner-Ville distribution and wavelet transforms. HSA modules have been tested with real heart sounds from 35 volunteers and proved to be quite efficient and robust while dealing with a large variety of pathological conditions.

  15. Wind Noise Reduction in a Non-Porous Subsurface Windscreen

    Science.gov (United States)

    Zuckerwar, Allan J.; Shams, Qamar A.; Knight, H. Keith

    2012-01-01

    Measurements of wind noise reduction were conducted on a box-shaped, subsurface windscreen made of closed cell polyurethane foam. The windscreen was installed in the ground with the lid flush with the ground surface. The wind was generated by means of a fan, situated on the ground, and the wind speed was measured at the center of the windscreen lid with an ultrasonic anemometer. The wind speed was controlled by moving the fan to selected distances from the windscreen. The wind noise was measured on a PCB Piezotronics 3†electret microphone. Wind noise spectra were measured with the microphone exposed directly to the wind (atop the windscreen lid) and with the microphone installed inside the windscreen. The difference between the two spectra comprises the wind noise reduction. At wind speeds of 3, 5, and 7 m/s, the wind noise reduction is typically 15 dB over the frequency range of 0.1-20 Hz.

  16. Nonvolatile Solid-State Charged-Polymer Gating of Topological Insulators into the Topological Insulating Regime

    Science.gov (United States)

    Ireland, R. M.; Wu, Liang; Salehi, M.; Oh, S.; Armitage, N. P.; Katz, H. E.

    2018-04-01

    We demonstrate the ability to reduce the carrier concentration of thin films of the topological insulator (TI) Bi2 Se3 by utilizing a nonvolatile electrostatic gating via corona charging of electret polymers. Sufficient electric field can be imparted to a polymer-TI bilayer to result in significant electron density depletion, even without the continuous connection of a gate electrode or the chemical modification of the TI. We show that the Fermi level of Bi2 Se3 is shifted toward the Dirac point with this method. Using terahertz spectroscopy, we find that the surface chemical potential is lowered into the bulk band gap (approximately 50 meV above the Dirac point and 170 meV below the conduction-band minimum), and it is stabilized in the intrinsic regime while enhancing electron mobility. The mobility of surface state electrons is enhanced to a value as high as approximately 1600 cm2/V s at 5 K.

  17. The 2010 calibration campaign for radon gas measuring instruments at PSI

    International Nuclear Information System (INIS)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2011-01-01

    Twenty radon measurement services or the respective analytical laboratories participated in the 2010 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) from August 27 th to August 31 st , 2010 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (track-etch, electronic and electret) and instruments (ionisation chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 595 Bq m -3 leading to a radon gas exposure of 57 kBq h m -3 . The exposure of 57 kBq h m -3 was close to the lower value of the measuring range defined in the Radon Measurement Ordinance ('Radon-Messmittelverordnung'). (authors)

  18. Template-based fluoroethylenepropylene piezoelectrets with tubular channels for transducer applications

    Science.gov (United States)

    Altafim, Ruy Alberto Pisani; Qiu, Xunlin; Wirges, Werner; Gerhard, Reimund; Altafim, Ruy Alberto Corrêa; Basso, Heitor Cury; Jenninger, Werner; Wagner, Joachim

    2009-07-01

    We describe the concept, the fabrication, and the most relevant properties of a piezoelectric-polymer system: Two fluoroethylenepropylene (FEP) films with good electret properties are laminated around a specifically designed and prepared polytetrafluoroethylene (PTFE) template at 300 °C. After removing the PTFE template, a two-layer FEP film with open tubular channels is obtained. For electric charging, the two-layer FEP system is subjected to a high electric field. The resulting dielectric barrier discharges inside the tubular channels yield a ferroelectret with high piezoelectricity. d33 coefficients of up to 160 pC/N have already been achieved on the ferroelectret films. After charging at suitable elevated temperatures, the piezoelectricity is stable at temperatures of at least 130 °C. Advantages of the transducer films include ease of fabrication at laboratory or industrial scales, a wide range of possible geometrical and processing parameters, straightforward control of the uniformity of the polymer system, flexibility, and versatility of the soft ferroelectrets, and a large potential for device applications e.g., in the areas of biomedicine, communications, production engineering, sensor systems, environmental monitoring, etc.

  19. Oscillating dipole layer facing a conducting plane: a classical analogue of the dynamical Casimir effect

    Energy Technology Data Exchange (ETDEWEB)

    Fosco, César D. [Centro Atómico Bariloche, Instituto Balseiro, Comisión Nacional de Energía Atómica, R8402AGP, Bariloche (Argentina); Lombardo, Fernando C., E-mail: lombardo@df.uba.ar [Departamento de Física Juan José Giambiagi, FCEyN UBA and IFIBA CONICET-UBA, Facultad de Ciencias Exactas y Naturales, Ciudad Universitaria, Pabellón I, 1428, Buenos Aires (Argentina)

    2015-12-17

    We study the properties of the classical electromagnetic radiation produced by two physically different yet closely related systems, which may be regarded as classical analogues of the dynamical Casimir effect. They correspond to two flat, infinite, parallel planes, one of them static and imposing perfect-conductor boundary conditions, while the other performs a rigid oscillatory motion. The systems differ just in the electrical properties of the oscillating plane: one of them is just a planar dipole layer (representing, for instance, a small-width electret). The other, instead, has a dipole layer on the side which faces the static plane, but behaves as a conductor on the other side: this can be used as a representation of a conductor endowed with patch potentials (on the side which faces the conducting plane). We evaluate, in both cases, the dissipative flux of energy between the system and its environment, showing that, at least for small mechanical oscillation amplitudes, it can be written in terms of the dipole layer autocorrelation function. We show that there are resonances as a function of the frequency of the mechanical oscillation.

  20. Cost results from the 1994 Fernald characterization field demonstration for uranium-contaminated soils

    International Nuclear Information System (INIS)

    Douthat, D.M.; Stewart, R.N.; Armstrong, A.Q.

    1995-04-01

    One of the principal objectives of the US Department of Energy (DOE) Office of Technology Development is to develop an optimum integrated system of technologies for removing uranium substances from soil. This system of technologies, through demonstration, must be proven in terms of cost reduction, waste minimization, risk reduction, and user applicability. To evaluate the effectiveness of these technologies, a field demonstration was conducted at the Fernald site in the summer of 1994. Fernald was selected as the host site for the demonstration based on environmental problems stemming from past production of uranium metal for defense-related applications. The following six alternative technologies were developed and/or demonstrated by the principal investigators in the Characterization Task Group at the field demonstration: (1) beta scintillation detector by Pacific Northwest Laboratory (PNL), (2) in situ gamma detector by PNL, (3) mobile laser ablation-inductively coupled plasma/atomic emission spectrometry (LA-ICP/AES) laboratory by Ames Laboratory, (4) long-range alpha detector (LRAD) by Los Alamos National Laboratory (LANL), (5) passive radon monitoring by ORNL, and (6) electret ion chamber by ORNL

  1. Unexpected levels and movement of radon in a large warehouse

    International Nuclear Information System (INIS)

    Gammage, R.B.; Espinosa, G.

    2004-01-01

    Alpha-track detectors, used in screening for radon, identified a large warehouse with levels of radon as high as 20 p Ci/l. This circumstance was unexpected because large bay doors were left open for much of the day to admit 1 8-wheeler trucks, and exhaust fans in the roof produced good ventilation. More detailed temporal and spatial investigations of radon and air-flow patterns were made with electret chambers, Lucas-cell flow chambers, tracer gas, smoke pencils and pressure sensing micrometers. An oval-dome shaped zone of radon (>4 p Ci/L) persisted in the central region of each of four separate bays composing the warehouse. Detailed studies of air movement in the bay with the highest levels of radon showed clockwise rotation of air near the outer walls with a central dead zone. Sub slab, radon-laden air ingresses the building through expansion joints between the floor slabs to produce the measured radon. The likely source of radon is air within porous, karst bedrock that underlies much of north-central Tennessee where the warehouse is situated

  2. Acoustic impedance rhinometry (AIR): a technique for monitoring dynamic changes in nasal congestion

    International Nuclear Information System (INIS)

    Patuzzi, Robert; Cook, Alison

    2014-01-01

    We describe a simple and inexpensive method for monitoring nasal air flow resistance using measurement of the small-signal acoustic input impedance of the nasal passage, similar to the audiological measurement of ear drum compliance with acoustic tympanometry. The method requires generation of a fixed sinusoidal volume–velocity stimulus using ear-bud speakers, and an electret microphone to monitor the resultant pressure fluctuation in the nasal passage. Both are coupled to the nose via high impedance silastic tubing and a small plastic nose insert. The acoustic impedance is monitored in real-time using a laptop soundcard and custom-written software developed in LabView 7.0 (National Instruments). The compact, lightweight equipment and fast time resolution lends the technique to research into the small and rapid reflexive changes in nasal resistance caused by environmental and local neurological influences. The acoustic impedance rhinometry technique has the potential to be developed for use in a clinical setting, where the need exists for a simple and inexpensive objective nasal resistance measurement technique. (paper)

  3. Modeling the filtration ability of stockpiled filtering facepiece

    Science.gov (United States)

    Rottach, Dana R.

    2016-03-01

    Filtering facepiece respirators (FFR) are often stockpiled for use during public health emergencies such as an infectious disease outbreak or pandemic. While many stockpile administrators are aware of shelf life limitations, environmental conditions can lead to premature degradation. Filtration performance of a set of FFR retrieved from a storage room with failed environmental controls was measured. Though within the expected shelf life, the filtration ability of several respirators was degraded, allowing twice the penetration of fresh samples. The traditional picture of small particle capture by fibrous filter media qualitatively separates the effect of inertial impaction, interception from the streamline, diffusion, settling, and electrostatic attraction. Most of these mechanisms depend upon stable conformational properties. However, common FFR rely on electrets to achieve their high performance, and over time heat and humidity can cause the electrostatic media to degrade. An extension of the Langevin model with correlations to classical filtration concepts will be presented. The new computational model will be used to predict the change in filter effectiveness as the filter media changes with time.

  4. International Symposium on Electrets (ISE 6) (6th) Held in Oxford, England on 1-3 September 1988

    Science.gov (United States)

    1988-09-01

    STIMULATED DISCHARGE J.Belana and P.Colomer Escuela Tecnica Superior de Ingenieros Industriales (UPC) Col6n 11, 08222 Terrassa (Barcelona),Spain. ABSTRACT...TSC measurements permitted Despax et al ,3] and Peres [4] to observe the influence of different gases on the sur- face dielectric properties of silica...adsorbed water is hydrogen bonded to hydroxyl groups in epoxV resin at room temperature. 5- INFINC. OF N2 AND C02. The influence of these two gases

  5. Carbon material based microelectromechanical system (MEMS): Fabrication and devices

    Science.gov (United States)

    Xu, Wenjun

    silicon and metal based microsystems. In this thesis, this mature technique was exploited to generate a variety of microelectrode structures to facilitate the micropatterning and manipulation of the CNTs. Selective deposition of electrically charged CNTs onto desired locations was realized in an EPD process through patterning of electric field lines created by the microelectrodes fabricated through MEMS techniques. A variety of 2-D and 3-D micropatterns of CNTs with waferscale areas have been successfully achieved in both rigid and elastic systems. The thickness and morphology of the generated CNT patterns was found to be readily controllable through the parameters of the fabrication process. Studies also showed that for this technique, high surface hydrophobicity of the non-conductive regions in microstructures was critical to accomplish well-defined selective micropatterning of CNTs. Upon clearing the hurdles of the CNT manipulation, a patterned PDMS/CNT nanocomposite was fabricated through the aforementioned approach and was incorporated, investigated and validated in elastic force/strain microsensors. The gauge factor of the sensor exhibited a strong dependence on both the initial resistance of the device and the applied strain. Detailed analysis of the data suggests that the piezoresistive effect of this specially constructed bi-layer composite could be due to three mechanisms, and the sensing mechanism may vary when physical properties of the CNT network embedded in the polymer matrix alter. The feasibility of the PDSM/CNT composite being utilized as an elastic electret was further explored. The nanocomposite composed of these two non-traditional electret materials exhibited electret characteristics with reasonable charge storage stability when charged using a corona discharge. The power generation capacity of the corona-charged composite has been characterized and successfully demonstrated in both a ball drop experiment and cyclic mechanical load experiments

  6. E-PERM alpha surface monitor

    International Nuclear Information System (INIS)

    Fricke, V.

    1999-01-01

    Innovative Technology Summary Reports are designed to provide potential users with the information they need to quickly determine if a technology would apply to a particular environmental management problem. They are also designed for readers who may recommend that a technology be considered by prospective users. Each report describes a technology, system, or process that has been developed and tested with funding from DOE's Office of Science and Technology (OST). The E-PERMreg s ign Alpha Surface Monitor is an integrating electret ion chamber innovative technology used to measure alpha radiation on surfaces of materials. The technology is best used on surfaces with low contamination levels such as areas with potential for free release, but can also be used in areas with higher levels of contamination. Measurement accuracy and production of the E-PERM reg s ign Alpha Surface Monitor compared favorably with the baseline technology. The innovative technology cost is approximately 28% higher than the baseline with an average unit cost per reading costing %6.04 vs. $4.36; however, the flexibility of the E-PERMreg s ign Alpha Surface Monitor may offer advantages in ALARA, reduction of operator error, waste minimization, and measurement accuracy

  7. Influences on indoor radon concentrations in Riyadh, Saudi Arabia

    International Nuclear Information System (INIS)

    Alghamdi, Abdulrahman S.; Aleissa, Khalid A.

    2014-01-01

    The influences on indoor radon concentrations in Riyadh, Saudi Arabia survey was carried out for 786 dwellings. The measurements were obtained by using a passive integrating ionization system with an E-Perm ® Electret ion chamber. Radon levels ranged from 1 to 195 Bq m −3 , with a mean value of 24.68 Bq m −3 , the geometric mean and the geometric standard deviation are 21 and 2 respectively. 98.5% of the results were below the action level recommended by WHO of 100 Bq.m −3 . The results were found to vary substantially due to types of houses and rooms, ventilation, seasons and building materials. Radon concentrations were higher in houses with no ventilation systems, and central air conditioners, and were relatively lower in well ventilated houses with red bricks and water air conditioners. - Highlights: • Limited information about indoor radon in Riyadh. • Several factors influence Radon level were investigated in 786 dwellings in Riyadh over one year. • Some results are over the action level and are advised to improve their ventilation systems

  8. Oscillating dipole layer facing a conducting plane: a classical analogue of the dynamical Casimir effect

    Energy Technology Data Exchange (ETDEWEB)

    Fosco, Cesar D. [Comision Nacional de Energia Atomica, Centro Atomico Bariloche, Instituto Balseiro, Bariloche (Argentina); Lombardo, Fernando C. [Ciudad Universitaria, Departamento de Fisica Juan Jose Giambiagi, FCEyN UBA y IFIBA CONICET-UBA, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina)

    2015-12-15

    We study the properties of the classical electromagnetic radiation produced by two physically different yet closely related systems, which may be regarded as classical analogues of the dynamical Casimir effect. They correspond to two flat, infinite, parallel planes, one of them static and imposing perfect-conductor boundary conditions, while the other performs a rigid oscillatory motion. The systems differ just in the electrical properties of the oscillating plane: one of them is just a planar dipole layer (representing, for instance, a small-width electret). The other, instead, has a dipole layer on the side which faces the static plane, but behaves as a conductor on the other side: this can be used as a representation of a conductor endowed with patch potentials (on the side which faces the conducting plane). We evaluate, in both cases, the dissipative flux of energy between the system and its environment, showing that, at least for small mechanical oscillation amplitudes, it can be written in terms of the dipole layer autocorrelation function. We show that there are resonances as a function of the frequency of the mechanical oscillation. (orig.)

  9. Oscillating dipole layer facing a conducting plane: a classical analogue of the dynamical Casimir effect

    International Nuclear Information System (INIS)

    Fosco, Cesar D.; Lombardo, Fernando C.

    2015-01-01

    We study the properties of the classical electromagnetic radiation produced by two physically different yet closely related systems, which may be regarded as classical analogues of the dynamical Casimir effect. They correspond to two flat, infinite, parallel planes, one of them static and imposing perfect-conductor boundary conditions, while the other performs a rigid oscillatory motion. The systems differ just in the electrical properties of the oscillating plane: one of them is just a planar dipole layer (representing, for instance, a small-width electret). The other, instead, has a dipole layer on the side which faces the static plane, but behaves as a conductor on the other side: this can be used as a representation of a conductor endowed with patch potentials (on the side which faces the conducting plane). We evaluate, in both cases, the dissipative flux of energy between the system and its environment, showing that, at least for small mechanical oscillation amplitudes, it can be written in terms of the dipole layer autocorrelation function. We show that there are resonances as a function of the frequency of the mechanical oscillation. (orig.)

  10. Radioactivity Measurements on Glazed Ceramic Surfaces.

    Science.gov (United States)

    Hobbs, T G

    2000-01-01

    A variety of commonly available household and industrial ceramic items and some specialty glass materials were assayed by alpha pulse counting and ion chamber voltage measurements for radioactivity concentrations. Identification of radionuclides in some of the items was performed by gamma spectroscopy. The samples included tableware, construction tiles and decorative tiles, figurines, and other products with a clay based composition. The concentrations of radioactivity ranged from near background to about four orders of magnitude higher. Almost every nuclide identification test demonstrated some radioactivity content from one or more of the naturally occurring radionuclide series of thorium or uranium. The glazes seemed to contribute most of the activity, although a sample of unglazed pottery greenware showed some activity. Samples of glazing paints and samples of deliberately doped glass from the World War II era were included in the test, as was a section of foam filled poster board. A glass disc with known (232)Th radioactivity concentration was cast for use as a calibration source. The results from the two assay methods are compared, and a projection of sensitivity from larger electret ion chamber devices is presented.

  11. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  12. Calibration of the pressure sensitivity of microphones by a free-field method at frequencies up to 80 khz.

    Science.gov (United States)

    Zuckerwar, Allan J; Herring, G C; Elbing, Brian R

    2006-01-01

    A free-field (FF) substitution method for calibrating the pressure sensitivity of microphones at frequencies up to 80 kHz is demonstrated with both grazing and normal-incidence geometries. The substitution-based method, as opposed to a simultaneous method, avoids problems associated with the nonuniformity of the sound field and, as applied here, uses a 1/4-in. air-condenser pressure microphone as a known reference. Best results were obtained with a centrifugal fan, which is used as a random, broadband sound source. A broadband source minimizes reflection-related interferences that can plague FF measurements. Calibrations were performed on 1/4-in. FF air-condenser, electret, and microelectromechanical systems (MEMS) microphones in an anechoic chamber. The uncertainty of this FF method is estimated by comparing the pressure sensitivity of an air-condenser FF microphone, as derived from the FF measurement, with that of an electrostatic actuator calibration. The root-mean-square difference is found to be +/- 0.3 dB over the range 1-80 kHz, and the combined standard uncertainty of the FF method, including other significant contributions, is +/- 0.41 dB.

  13. Triboelectricity: macroscopic charge patterns formed by self-arraying ions on polymer surfaces.

    Science.gov (United States)

    Burgo, Thiago A L; Ducati, Telma R D; Francisco, Kelly R; Clinckspoor, Karl J; Galembeck, Fernando; Galembeck, Sergio E

    2012-05-15

    Tribocharged polymers display macroscopically patterned positive and negative domains, verifying the fractal geometry of electrostatic mosaics previously detected by electric probe microscopy. Excess charge on contacting polyethylene (PE) and polytetrafluoroethylene (PTFE) follows the triboelectric series but with one caveat: net charge is the arithmetic sum of patterned positive and negative charges, as opposed to the usual assumption of uniform but opposite signal charging on each surface. Extraction with n-hexane preferentially removes positive charges from PTFE, while 1,1-difluoroethane and ethanol largely remove both positive and negative charges. Using suitable analytical techniques (electron energy-loss spectral imaging, infrared microspectrophotometry and carbonization/colorimetry) and theoretical calculations, the positive species were identified as hydrocarbocations and the negative species were identified as fluorocarbanions. A comprehensive model is presented for PTFE tribocharging with PE: mechanochemical chain homolytic rupture is followed by electron transfer from hydrocarbon free radicals to the more electronegative fluorocarbon radicals. Polymer ions self-assemble according to Flory-Huggins theory, thus forming the experimentally observed macroscopic patterns. These results show that tribocharging can only be understood by considering the complex chemical events triggered by mechanical action, coupled to well-established physicochemical concepts. Patterned polymers can be cut and mounted to make macroscopic electrets and multipoles.

  14. Intercomparison and intercalibration of active and passive radon detectors in North America

    International Nuclear Information System (INIS)

    George, A.C.

    1991-04-01

    The state of the art of the most commonly used instrumentation for radon measurements was evaluated at an intercomparison exercise held at the Environmental Measurements Laboratory, between April 24, and May 10, 1990. More than 50 sets of active and passive devices were submitted for evaluation by 30 laboratories from private firms, local, state and federal agencies and universities. There were basically five different types of detectors representing the majority of instruments used to assess the indoor airborne concentration of radon. After exposure, the devices were returned to the participating laboratories for analysis. The results reported to EML indicate that the overall performance was good with the majority of the participating laboratories reporting mean results within 10% of the EML reference values. In general, the majority of radon measuring devices gave slightly lower readings than the reference values. The individual measurements made with activated carbon collectors of both the open face and diffusion barrier type and the electret/ionization chambers showed the best precision and accuracy. The nuclear track detectors showed mixed results, exhibiting the largest measurement errors. This suggests that there are problems with sensitivity and with quality control procedures that must be addressed to improve their performance. 7 refs., 1 fig., 2 tabs

  15. A hybrid strain and thermal energy harvester based on an infra-red sensitive Er3+ modified poly(vinylidene fluoride) ferroelectret structure.

    Science.gov (United States)

    Ghosh, Sujoy Kumar; Xie, Mengying; Bowen, Christopher Rhys; Davies, Philip R; Morgan, David J; Mandal, Dipankar

    2017-12-01

    In this paper, a novel infra-red (IR) sensitive Er 3+ modified poly(vinylidene fluoride) (PVDF) (Er-PVDF) film is developed for converting both mechanical and thermal energies into useful electrical power. The addition of Er 3+ to PVDF is shown to improve piezoelectric properties due to the formation of a self-polarized ferroelectric β-phase and the creation of an electret-like porous structure. In addition, we demonstrate that Er 3+ acts to enhance heat transfer into the Er-PVDF film due to its excellent infrared absorbance, which, leads to rapid and large temperature fluctuations and improved pyroelectric energy transformation. We demonstrate the potential of this novel material for mechanical energy harvesting by creating a durable ferroelectret energy harvester/nanogenerator (FTNG). The high thermal stability of the β-phase enables the FTNG to harvest large temperature fluctuations (ΔT ~ 24 K). Moreover, the superior mechanosensitivity, S M  ~ 3.4 VPa -1 of the FTNG enables the design of a wearable self-powered health-care monitoring system by human-machine integration. The combination of rare-earth ion, Er 3+ with the ferroelectricity of PVDF provides a new and robust approach for delivering smart materials and structures for self-powered wireless technologies, sensors and Internet of Things (IoT) devices.

  16. Parametric Investigation of Laser Doppler Microphones

    Science.gov (United States)

    Daoud, M.; Naguib, A.

    2002-11-01

    The concept of a Laser Doppler Microphone (LDM) is based on utilizing the Doppler frequency shift of a focused laser beam to measure the unsteady velocity of the center point of a flexible polymer diaphragm that is mounted on top of a hole and subjected to the unsteady pressure. Time integration of the velocity signal yields a time series of the diaphragm displacement, which can be converted to pressure from knowledge of the sensor's deflection sensitivity. In our APS/DFD presentation last year, the stringent frequency resolution requirement of these new sensors and methods to meet this requirement were discussed. Here, the dependence of the sensor characteristics (sensitivity, bandwidth, and noise floor) on various significant parameters is investigated in detail by calibrating the sensor in a plane wave tube in the frequency range of 50 - 5000 Hz. Parameters investigated include sensor diaphragm material and thickness, sensor size, damping of the diaphragm motion and laser beam spot size. The results shed light on the operating limits of the new sensor and demonstrate its ability to conduct high-spatial-resolution measurements in typical high-Reynolds-number test facilities. Moreover, calibrated LDM sensors were used to conduct measurements in a separating/reattaching flow and the results are compared to classical electret-type microphones with a similar sensing diameter.

  17. Characterization of seeds with different moisture content by photoacoustic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez Pacheco, Arturo; Hernandez Aguilar, Claudia; Marinez Ortiz, Efrain [Instituto Politecnico Nacional, Sepi-Esime, Zacatenco. Unidad Profesional ' Adolfo Lopez Mateos' . Col. Lindavista. Mexico D.F., CP 07738 (Mexico); Cruz-Orea, Alfredo; Ayala-Maycotte, Esther, E-mail: fartur@hotmail.co [Departamento de Fisica, CINVESTAV - IPN, A. P. 14-740, Mexico D.F., C.P. 07360 (Mexico)

    2010-03-01

    Photoacoustic (PA) technique has important applications for material characterization and nondestructive evaluation of opaque solid materials. PA microscopy allows the acquisition of information of samples with inhomogeneous structures as agricultural seeds. A determining factor for seed safe storage is their moisture content. Seeds stored at high moisture content exhibit increased respiration, heating, and fungal invasion resulting in poor seed vigor and viability. Low moisture content, in the seed to be stored, is the best prevention for these problems. In this study, Photoacoustic Microscopy (PAM) was used to characterize seeds with different moisture content. In the PAM experimental setup the photoacoustic cell and its sensor, an electret microphone, are mounted on an x-y stage of mobile axes, with spatial resolution of 70 {mu}m. The excitation light source is a fiber coupled laser diode, at 650 nm wavelength, modulated in intensity at 1 Hz of frequency, by the reference oscillator of a lock-in amplifier. By using a microscope objective the laser beam was focused on the seed surface. The resolution was enough to obtain differences in the obtained images, which are dependent on the moisture content. This method, to study differences in the seed moisture content, is nondestructive and could be useful for a sustainable Agriculture.

  18. Indoor {sup 22}Rn and {sup 222}Rn concentration measurements inside the Teotihuacan pyramids using NTD and E-PERM methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G. [Instituto de Fisica, UNAM, Apartado Postal 20-364, 01000 Mexico, D.F. (Mexico)]. E-mail: espinosa@fisica.unam.mx; Golzarri, J.I. [Instituto de Fisica, UNAM, Apartado Postal 20-364, 01000 Mexico, D.F. (Mexico); Martinez, T. [Facultad de Quimica, UNAM, Edificio D, Ciudad Universitaria, Mexico, D.F. (Mexico); Navarrete, M. [Facultad de Quimica, UNAM, Edificio D, Ciudad Universitaria, Mexico, D.F. (Mexico); Bogard, J. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6480 (United States); Martinez, G. [Coordinacion Nacional de Conservacion del Patrimonio Cultural, Xicotencatl y General Anaya s/n, 04120 Mexico, D.F. (Mexico); Juarez, F. [Instituto de Geofisica, UNAM, Ciudad Universitaria, 04510 Mexico, D.F. (Mexico)

    2005-11-15

    Measurements of {sup 22}Rn (Thoron) and {sup 222}Rn (Radon) concentrations, inside the Sun and Moon pyramids of Teotihuacan's archeological zone in Mexico, are reported in this work. Two well-established methods, nuclear track detectors (NTDs), using open-close end cups with internal and external detectors of CR-39 polymer, and electret-passive environmental radon monitoring (E-PERM) were used for the measurements. This experiment had two objectives: to obtain better confidence in the {sup 22}Rn and {sup 222}Rn measurements inside the archeological tunnels, and to compare the data obtained in each one of the two methods. This experiment is specially interesting because of the very peculiar conditions where the measurements are made: high humidity, labyrinths with air currents, but almost constant temperature inside of the pyramid tunnels and galleries, notwithstanding of the temperature changes between the day and the night outside of the pyramid body. The {sup 222}Rn concentrations found in both the pyramids were lower than the action level proposed by the ICRP-65. These tunnels are not open to the public, but researchers from the Anthropology Institutions spend part of their time working there, in periods varying from 3 to 5 months.

  19. Undersafe: Monitoring safety parameters in touristic mines and caves

    Science.gov (United States)

    Parcerisa, David; Sanmiquel, Lluís; Alfonso, Pura; Oliva, Josep

    2014-05-01

    sensors. Although the costs of the most sensible ones are out of the limits needed for our purposes, but some non-expensive accelerometers will be tested in real environment. All these systems have been tested and it can be concluded that results have been positive for the following technologies: piezoelectric, Electret (airborne and underground) and geophone. On the contrary, accelerometer and movement sensor provided negative results. The most sensible sensor that we have found is Electret that, in turn, is the most sensitive one to out of ground environmental noise (relevant in order to discard surface vibrations effect). All sensors can provide detections in a range of 15m. Low cost rock falling detectors, in cercles of 30 m of diameter are feasible. Also detection for longer distances, up to 80 meters, is feasible, but not advisable for low-cost application. Aknowledgements: Undersafe is an European project under the auspices of the EU 7h Framework Program. EDMA Innovation S.L. deeply contributed to the development of this study.

  20. The Electret Radon Sniffer as a diagnostic tool for optimizing the efficiency of sub-slab ventilation systems and/or sealing

    International Nuclear Information System (INIS)

    Yates, J.H.; Kotrappa, P.

    1990-01-01

    In this paper a method for the measurement and interpretation of radon levels beneath a poured concrete slab floor is presented, along with application strategies intended to guide the mitigator in his efforts to effect an optimally efficient sealing or sub-slab mitigation system installation in the structure so measured. Case studies are presented for illustrative purposes, and cautions and uncertainties in this method are detailed, along with related areas of inquiry. The presumed greatest utility of this method is in attacking radon in structures evidencing poor sub-slab communication

  1. Charge patterns as templates for the assembly of layered biomolecular structures.

    Science.gov (United States)

    Naujoks, Nicola; Stemmer, Andreas

    2006-08-01

    Electric fields are used to guide the assembly of biomolecules in predefined geometric patterns on solid substrates. Local surface charges serve as templates to selectively position proteins on thin-film polymeric electret layers, thereby creating a basis for site-directed layered assembly of biomolecular structures. Charge patterns are created using the lithographic capabilities of an atomic force microscope, namely by applying voltage pulses between a conductive tip and the sample. Samples consist of a poly(methyl methacrylate) layer on a p-doped silicon support. Subsequently, the sample is developed in a water-in-oil emulsion, consisting of a dispersed aqueous phase containing biotin-modified immunoglobulinG molecules, and a continuous nonpolar, insulating oil phase. The electrostatic fields cause a net force of (di)electrophoretic nature on the droplet, thereby guiding the proteins to the predefined locations. Due to the functionalization of the immunoglobulinG molecules with biotin-groups, these patterns can now be used to initiate the localized layer-by-layer assembly of biomolecules based on the avidin-biotin mechanism. By binding 40 nm sized biotin-labelled beads to the predefined locations via a streptavidin linker, we verify the functionality of the previously deposited immunoglobulinG-biotin. All assembly steps following the initial deposition of the immunoglobulinG from emulsion can conveniently be conducted in aqueous solutions. Results show that pattern definition is maintained after immersion into aqueous solution.

  2. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  3. The effects of ambient conditions on the passive dust sampler when used in coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Hemingway, M.; Thorpe, A.

    1998-09-01

    A previous feasibility study of the Health and Safety Laboratory (HSL) electret-based passive dust sampler carried out during site sampling in coal mines showed that the measurements made with the passive sampler and those made with the MRE sampler correlated well in each of two mines, but the ratios of samples obtained with the passive sampler and the MRE sampler in the two mines were different. This means the passive sampler would need a separate calibration for each coal mine in which it was used. Laboratory tests and further underground trials were carried out to quantify the possible effects of temperature and humidity on ratios. The passive dust samplers used at Maltby Colliery in the UK were found to pass the acceptance criteria according to the CEN standard for the assessment of the performance of instruments for the measurement of airborne particles, provided that samplers exposed when coal was not being cut were not included in the analysis. Temperature and relative humidity slightly affected the behaviour of the passive sampler during laboratory trials and relative humidity was found to possibly affect the behaviour during field trials. Ventilation rates had no effect on the passive sampler behaviour but the orientation of the passive dust sampler with respect to air flow affected the behaviour during laboratory trials. Further work is needed to quantify effects. 7 refs., 14 figs., 3 tabs.

  4. [Radon risk in healthcare facilities: environmental monitoring and effective dose].

    Science.gov (United States)

    Cammarota, B; Cascone, Maria Teresa; De Paola, L; Schillirò, F; Del Prete, U

    2009-01-01

    Radon, the second cause of lung cancer after smoking (WHO- IARC), is a natural, radioactive gas, which originates from the soil and pollutes indoor air, especially in closed or underground spaces. The purpose of this study was to determine the concentration of radon gas, its effective dose, and the measurement of microclimatic degrees C; U.R. % and air velocity in non-academic intensive care units of public hospitals in the Naples area. The annual average concentrations of radon gas were detected with EIC type ionization electret chambers, type LLT with exposure over four 3-month periods. The concentrations varied for all health facilities between 186 and 1191 Bq/m3. Overall, the effective dose of exposure to radon gas of 3mSv/a recommended by Italian legislation was never exceeded. The concentration of radon gas showed a decreasing trend starting from the areas below ground level to those on higher floors; such concentrations were also influenced by natural and artificial ventilation of the rooms, building materials used for walls, and by the state of maintenance and improvements of the building (insulation of floors and walls). The data obtained confirmed the increased concentration of radionuclides in the yellow tuff of volcanic origin in the Campania Region and the resulting rate of release of radon gas, whereas the reinforced concrete structure (a hospital located on the hillside), which had the lowest values, proved to provide good insulation against penetration and accumulation of radon gas.

  5. 1994 Fernald field characterization demonstration program data report

    International Nuclear Information System (INIS)

    Rautman, C.A.; Cromer, M.V.; Newman, G.C.; Beiso, D.A.

    1995-12-01

    The 1994 Fernald field characterization demonstration program, hosted by Fernald Environmental Management Project, was established to investigate technologies that are applicable to the characterization and remediation of soils contaminated with uranium. An important part of this effort was evaluating field-screening tools potentially capable of acquiring high-resolution information on uranium contamination distribution in surface soils. Further-more, the information needed to be obtained in a cost- and time-efficient manner. Seven advanced field-screening technologies were demonstrated at a uranium-contaminated site at Fernald, located 29 kilometers northwest of Cincinnati, Ohio. The seven technologies tested were: (1) alpha-track detectors, (2) a high-energy beta scintillometer, (3) electret ionization chambers, (4) and (5) two variants of gamma-ray spectrometry, (6) laser ablation-inductively coupled plasma-atomic emission spectroscopy, and (7) long-range alpha detection. The goals of this field demonstration were to evaluate the capabilities of the detectors and to demonstrate their utility within the US Department of Energy's Environmental Restoration Program. Identical field studies were conducted using four industry-standard characterization tools: (1) a sodium-iodide scintillometer, (2) a low-energy FIDLER scintillometer, (3) a field-portable x-ray fluorescence detector, and (4) standard soil sampling coupled with laboratory analysis. Another important aspect of this program was the application of a cost/risk decision model to guide characterization of the site. This document is a compilation of raw data submitted by the technologies and converted total uranium data from the 1994 Fernald field characterization demonstration

  6. Numerical calculations of effective elastic properties of two cellular structures

    International Nuclear Information System (INIS)

    Tuncer, Enis

    2005-01-01

    Young's moduli of regular two-dimensional truss-like and eye-shaped structures are simulated using the finite element method. The structures are idealizations of soft polymeric materials used in ferro-electret applications. In the simulations, the length scales of the smallest representative units are varied, which changes the dimensions of the cell walls in the structures. A power-law expression with a quadratic as the exponent term is proposed for the effective Young's moduli of the systems as a function of the solid volume fraction. The data are divided into three regions with respect to the volume fraction: low, intermediate and high. The parameters of the proposed power-law expression in each region are later represented as a function of the structural parameters, the unit-cell dimensions. The expression presented can be used to predict a structure/property relationship in materials with similar cellular structures. The contribution of the cell-wall thickness to the elastic properties becomes significant at concentrations >0.15. The cell-wall thickness is the most significant factor in predicting the effective Young's modulus of regular cellular structures at high volume fractions of solid. At lower concentrations of solid, the eye-shaped structure yields a lower Young's modulus than a truss-like structure with similar anisotropy. Comparison of the numerical results with those of experimental data for poly(propylene) show good agreement regarding the influence of cell-wall thickness on elastic properties of thin cellular films

  7. Electroactive polymers for healthcare and biomedical applications

    Science.gov (United States)

    Bauer, Siegfried

    2017-04-01

    Electroactivity was noticed early in biological substances, including proteins, polynucleotides and enzymes, even piezoand pyroelectricity were found in wool, hair, wood, bone and tendon. Recently, ferroelectricity has been identified in a surprisingly large number of biologically relevant materials, including hydroxyapatite, aortic walls and elastin. Inspired by the variety of natural electroactive materials, a wealth of new elastomers and polymers were designed recently, including an all organic elastomer electret and self-healing dielectric elastomers. Let's further draw inspiration from nature and widen the utilization of electroactive polymers towards (mobile) healthcare and biomedical applications. Ferroelectrets, internally charged polymer foams with a strong piezoelectric thickness coefficient are employed in biomedical sensing, for example as blood pressure and pulse sensor, as vital signs monitor or for the detection of tonicclonic seizures. Piezo- and pyroelectric polymers are booming in printed electronics research. They provide electronic skin the ability to "feel" pressure and temperature changes, or to generate electrical energy from vibrations and motions, even from contractile and relaxation motions of the heart and lung. Dielectric elastomers are pioneered by StretchSense as wearable motion capture sensors, monitoring pressure, stretch, bend and shear, quantifying comfort in sports and healthcare. On the cellular level, electroactive polymer arrays are used to study mechanotransduction of individual cells. Ionic electroactive polymers show potential to be used in implantable electroactive biomedical devices. Already with the currently available science and technology, we are at the verge of witnessing the demonstration of truly complex bionic systems.

  8. Evaluation of measurement reproducibility using the standard-sites data, 1994 Fernald field characterization demonstration project

    International Nuclear Information System (INIS)

    Rautman, C.A.

    1996-02-01

    The US Department of Energy conducted the 1994 Fernald (Ohio) field characterization demonstration project to evaluate the performance of a group of both industry-standard and proposed alternative technologies in describing the nature and extent of uranium contamination in surficial soils. Detector stability and measurement reproducibility under actual operating conditions encountered in the field is critical to establishing the credibility of the proposed alternative characterization methods. Comparability of measured uranium activities to those reported by conventional, US Environmental Protection Agency (EPA)-certified laboratory methods is also required. The eleven (11) technologies demonstrated included (1) EPA-standard soil sampling and laboratory mass-spectroscopy analyses, and currently-accepted field-screening techniques using (2) sodium-iodide scintillometers, (3) FIDLER low-energy scintillometers, and (4) a field-portable x-ray fluorescence spectrometer. Proposed advanced characterization techniques included (5) alpha-track detectors, (6) a high-energy beta scintillometer, (7) electret ionization chambers, (8) and (9) a high-resolution gamma-ray spectrometer in two different configurations, (10) a field-adapted laser ablation-inductively coupled plasma-atomic emission spectroscopy (ICP-AES) technique, and (11) a long-range alpha detector. Measurement reproducibility and the accuracy of each method were tested by acquiring numerous replicate measurements of total uranium activity at each of two ''standard sites'' located within the main field demonstration area. Meteorological variables including temperature, relative humidity. and 24-hour rainfall quantities were also recorded in conjunction with the standard-sites measurements

  9. Printing Semiconductor-Insulator Polymer Bilayers for High-Performance Coplanar Field-Effect Transistors.

    Science.gov (United States)

    Bu, Laju; Hu, Mengxing; Lu, Wanlong; Wang, Ziyu; Lu, Guanghao

    2018-01-01

    Source-semiconductor-drain coplanar transistors with an organic semiconductor layer located within the same plane of source/drain electrodes are attractive for next-generation electronics, because they could be used to reduce material consumption, minimize parasitic leakage current, avoid cross-talk among different devices, and simplify the fabrication process of circuits. Here, a one-step, drop-casting-like printing method to realize a coplanar transistor using a model semiconductor/insulator [poly(3-hexylthiophene) (P3HT)/polystyrene (PS)] blend is developed. By manipulating the solution dewetting dynamics on the metal electrode and SiO 2 dielectric, the solution within the channel region is selectively confined, and thus make the top surface of source/drain electrodes completely free of polymers. Subsequently, during solvent evaporation, vertical phase separation between P3HT and PS leads to a semiconductor-insulator bilayer structure, contributing to an improved transistor performance. Moreover, this coplanar transistor with semiconductor-insulator bilayer structure is an ideal system for injecting charges into the insulator via gate-stress, and the thus-formed PS electret layer acts as a "nonuniform floating gate" to tune the threshold voltage and effective mobility of the transistors. Effective field-effect mobility higher than 1 cm 2 V -1 s -1 with an on/off ratio > 10 7 is realized, and the performances are comparable to those of commercial amorphous silicon transistors. This coplanar transistor simplifies the fabrication process of corresponding circuits. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Natural radionuclides concentration in underground mine materials

    Energy Technology Data Exchange (ETDEWEB)

    Santos, T.O.; Rocha, Z.; Taveira, N.F.; Takahashi, L.C.; Pineiro, M.M., E-mail: talitaolsantos@yahoo.com.br, E-mail: rochaz@cdtn.br, E-mail: mayarapinheiroduarte@gmail.com, E-mail: lauratakahashi@hotmail.com, E-mail: natyfontaveira@hotmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Borges, P.F.; Cruz, P.; Gouvea, V.A.; Siqueira, J.B., E-mail: vgouvea@cnen.gov.br, E-mail: flavia.borges@cnen.gov.br, E-mail: pcruz@cnen.gov.br, E-mail: jbsiquei@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Natural Radionuclides are present in earth's environment since its origin. The main radionuclides present are {sup 40}K, as well as, {sup 238}U and {sup 232}Th with their decay products. These radionuclides occur in minerals in different activity concentration associated with geological and geochemical conditions, appearing at different levels from point to point in the world. Underground mines may present a high natural background radiation which is due to the presence of these radiogenic heavy minerals. To address this concern, this work outlines on the characterization of the natural radionuclides presence in underground mines in Brazil which are located in many cases on higher radiation levels bed rocks. The radon concentration was measured by using E-PERM Electrets Ion Chamber, AlphaGUARD and CR-39 track etch detectors. The radon progeny was determined by using DOSEman detector. Radon concentration measurement in groundwater was performed by using RAD7 detector. The {sup 238}U and {sup 232}Th activity concentration in ore and soil samples were determined by using Neutron Activation Analysis using TRIGA MARK I IPR-R1 Reactor. Gamma spectrometry was used to determine {sup 226}Ra, {sup 228}Ra and {sup 40}K activity concentrations. The results show that the natural radioactivity varies considerably from mine to mine and that there are not risks of radiological damage for exposed workers in these cases. Based on these data, recommendations for Brazilian regulatory standards are presented. (author)

  11. Natural radionuclides concentration in underground mine materials

    International Nuclear Information System (INIS)

    Santos, T.O.; Rocha, Z.; Taveira, N.F.; Takahashi, L.C.; Pineiro, M.M.; Borges, P.F.; Cruz, P.; Gouvea, V.A.; Siqueira, J.B.

    2017-01-01

    Natural Radionuclides are present in earth's environment since its origin. The main radionuclides present are 40 K, as well as, 238 U and 232 Th with their decay products. These radionuclides occur in minerals in different activity concentration associated with geological and geochemical conditions, appearing at different levels from point to point in the world. Underground mines may present a high natural background radiation which is due to the presence of these radiogenic heavy minerals. To address this concern, this work outlines on the characterization of the natural radionuclides presence in underground mines in Brazil which are located in many cases on higher radiation levels bed rocks. The radon concentration was measured by using E-PERM Electrets Ion Chamber, AlphaGUARD and CR-39 track etch detectors. The radon progeny was determined by using DOSEman detector. Radon concentration measurement in groundwater was performed by using RAD7 detector. The 238 U and 232 Th activity concentration in ore and soil samples were determined by using Neutron Activation Analysis using TRIGA MARK I IPR-R1 Reactor. Gamma spectrometry was used to determine 226 Ra, 228 Ra and 40 K activity concentrations. The results show that the natural radioactivity varies considerably from mine to mine and that there are not risks of radiological damage for exposed workers in these cases. Based on these data, recommendations for Brazilian regulatory standards are presented. (author)

  12. Radon generation and transport in and around a gold mine tailings dam in South Africa

    International Nuclear Information System (INIS)

    Speelman, W.J.; Lindsay, R.; Newman, R.T.; Meijer, R.J. de

    2006-01-01

    Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the 40 K, 238 U and 232 Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas measurements were performed at certain points on the mine tailings with a continuous radon monitor; R.A.D.7, and emanation coefficients were measured with electret technology. These parameters have been combined with the activity concentrations to obtain an average radon exhalation rate of about 0.1 Bq.m -2 .s -1 (with an uncertainty of about 20%) from the tailings dam. The purpose of the study is to also review and develop a mathematical model for radon activity concentration predictions in gold mine dumps. (authors)

  13. Radon generation and transport in and around a gold mine tailings dam in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Speelman, W.J.; Lindsay, R. [Western Cape Univ., Dept. of Physics (South Africa); Newman, R.T. [IThemba LABS, Somerset West (South Africa); Meijer, R.J. de [Nuclear Geophysics Division (NGD), KVI, Rijksuniversiteit Groningen (Netherlands)

    2006-07-01

    Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas measurements were performed at certain points on the mine tailings with a continuous radon monitor; R.A.D.7, and emanation coefficients were measured with electret technology. These parameters have been combined with the activity concentrations to obtain an average radon exhalation rate of about 0.1 Bq.m{sup -2}.s{sup -1} (with an uncertainty of about 20%) from the tailings dam. The purpose of the study is to also review and develop a mathematical model for radon activity concentration predictions in gold mine dumps. (authors)

  14. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  15. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  16. Radon origin in the metropolitan region of Belo Horizonte, Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Santos, Talita de O.; Oliveira, H. de; Rocha, Zildete; Dias, Antonio F.; Malta, Ricardo S.V.

    2011-01-01

    The main sources of radon concentration in buildings are the underground surrounding soil and bedrock, construction materials and underground water supply. However, the contribution from these sources to the indoor radon level depends on many factors, such as type of the building, geology and pedology of the site and also the floor level. Focusing on this concern, the present work outlines on the characterization of the radon concentration in two different kinds of buildings - slab-on-grade dwellings and apartments on the second floor and above - in the Metropolitan Region of Belo Horizonte, Brazil, which is located in a large part on granite embasement area, the Granitic Gnaissic Complex. The radon concentration in dwellings and apartments, measured by using E-PERM Electrets Ion Chamber, ranged from 18.5 to 1591.0 Bqm -3 (mean value 114.7 ± 5.5 Bqm -3 ) and 3.7 to 185.0 Bqm -3 (mean value 70.3 ± 6.7 Bqm -3 ), respectively. Thus, the highest radon concentration is present in dwellings not in apartments, suggesting that the enhanced radon concentration maybe was originated mainly from local geological settings instead of other sources. In order to confirm this hypothesis, the measurements of the soil gas radon concentration were carried out by using AlphaGUARD PQ2000PRO detector and 226 Ra ( 214 Bi) and 224 Ra ( 212 Pb) specific activity in construction materials were determined by using gamma-ray spectrometry HPGe detector. These results confirmed the local geological setting as the main radon source. Moreover, radon concentration much higher than United States Environmental Protection Agency USEPA action level 148Bq.m -3 occurred only in slab-on-grade dwellings. (author)

  17. Seasonal correction factors in radon exposure assessment: are they help or hindrance?

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Phillips, P.S.; Woolridge, A.C.; Crockett, R.G.M.

    2008-01-01

    Northern Hemisphere radon levels are generally higher in Winter than in Summer, primarily due to the increased interior/exterior temperature difference during the heating season, which results in greater atmospheric pressure differential and enhanced radon ingress. Following a survey of domestic radon levels in the United Kingdom (UK), the former National Radiological Protection Board (NRPB) established measurement protocols and promulgated nationally-applicable Seasonal Correction Factors (SCF). These factors convert a one-month or three-month radon concentration measurement, commencing in any month of the year, to an annual mean radon concentration. Subsequent study suggests that this approach may not be sufficiently sensitive to local conditions, and a major independent investigation reported seasonal correction factors specific to nine geographic regions, together with a composite set applicable to all regions. Similar geographical variability has been observed in other countries. In a recent evaluation of the applicability of short-term exposures in quantifying long-term domestic radon levels, radon levels in 34 houses were monitored over a 12-month period with 1-week, 1-month and 3-month exposures. Radon concentration variation departed significantly from that expected on the basis of the recommended SCFs, with year-end discontinuities at all exposure durations. Weekly monitoring with electrets was continued in three of these locations for four years. Short-term variations in radon levels were observed, particularly during the shorter exposures, and this dataset has also shown year-on-year variations. Overall, SCFs derived from this dataset are significantly lower than those recommended, but are comparable with other results from the UK and elsewhere, particularly those that recognise geological diversity and are consequently prepared on a regional rather than a national basis. These findings call into question the validity of using nationally

  18. Influence of Low-Temperature Plasma Treatment on The Liquid Filtration Efficiency of Melt-Blown PP Nonwovens in The Conditions of Simulated Use of Respiratory Protective Equipment

    Directory of Open Access Journals (Sweden)

    Majchrzycka Katarzyna

    2017-06-01

    Full Text Available Filtering nonwovens produced with melt-blown technology are one of the most basic materials used in the construction of respiratory protective equipment (RPE against harmful aerosols, including bio- and nanoaerosols. The improvement of their filtering properties can be achieved by the development of quasi-permanent electric charge on the fibres. Usually corona discharge method is utilized for this purpose. In the presented study, it was assumed that the low-temperature plasma treatment could be applied as an alternative method for the manufacturing of conventional electret nonwovens for the RPE construction. Low temperature plasma treatment of polypropylene nonwovens was carried out with various process gases (argon, nitrogen, oxygen or air in a wide range of process parameters (gas flow velocity, time of treatment and power supplied to the reactor electrodes. After the modification, nonwovens were evaluated in terms of filtration efficiency of paraffin oil mist. The stability of the modification results was tested after 12 months of storage and after conditioning at elevated temperature and relative humidity conditions. Moreover, scanning electron microscopy and ATR-IR spectroscopy were used to assess changes in surface topography and chemical composition of the fibres. The modification of melt-blown nonwovens with nitrogen, oxygen and air plasma did not result in a satisfactory improvement of the filtration efficiency. In case of argon plasma treatment, up to 82% increase of filtration efficiency of paraffin oil mist was observed in relation to untreated samples. This effect was stable after 12 months of storage in normal conditions and after thermal conditioning in (70 ± 3°C for 24 h. The use of low-temperature plasma treatment was proven to be a promising improvement direction of filtering properties of nonwovens used for the protection of respiratory tract against harmful aerosols.

  19. Gravimetric Measurements of Filtering Facepiece Respirators Challenged With Diesel Exhaust.

    Science.gov (United States)

    Satish, Swathi; Swanson, Jacob J; Xiao, Kai; Viner, Andrew S; Kittelson, David B; Pui, David Y H

    2017-07-01

    Elevated concentrations of diesel exhaust have been linked to adverse health effects. Filtering facepiece respirators (FFRs) are widely used as a form of respiratory protection against diesel particulate matter (DPM) in occupational settings. Previous results (Penconek A, Drążyk P, Moskal A. (2013) Penetration of diesel exhaust particles through commercially available dust half masks. Ann Occup Hyg; 57: 360-73.) have suggested that common FFRs are less efficient than would be expected for this purpose based on their certification approvals. The objective of this study was to measure the penetration of DPM through NIOSH-certified R95 and P95 electret respirators to verify this result. Gravimetric-based penetration measurements conducted using polytetrafluoroethylene (PTFE) and polypropylene (PP) filters were compared with penetration measurements made with a Scanning Mobility Particle Sizer (SMPS, TSI Inc.), which measures the particle size distribution. Gravimetric measurements using PP filters were variable compared to SMPS measurements and biased high due to adsorption of gas phase organic material. Relatively inert PTFE filters adsorbed less gas phase organic material resulting in measurements that were more accurate. To attempt to correct for artifacts associated with adsorption of gas phase organic material, primary and secondary filters were used in series upstream and downstream of the FFR. Correcting for adsorption by subtracting the secondary mass from the primary mass improved the result for both PTFE and PP filters but this correction is subject to 'equilibrium' conditions that depend on sampling time and the concentration of particles and gas phase hydrocarbons. Overall, the results demonstrate that the use of filters to determine filtration efficiency of FFRs challenged with diesel exhaust produces erroneous results due to the presence of gas phase hydrocarbons in diesel exhaust and the tendency of filters to adsorb organic material. Published by

  20. Environmental pollution and health in the metropolitan zone of Mexico Valley

    International Nuclear Information System (INIS)

    Martinez, T.; Lartigue, J.; Cabrera, L.; Ramirez, A.

    2002-01-01

    Concerned about pollution in the Metropolitan Zone of Mexico Valley and its effects on inhabitant's health, the Faculty of Chemistry has been performing the monitoring of radon levels and heavy metals in environmental samples, since 1992. Samples consisted in aerosol fillers classified as Total Suspended Particles (TSP) and Respirable Particles (PM10) as well as dry fallout. Surveys were carried out in several zones covering the MZMV and different seasons along successive years. Metallic elements were determined by Instrumental Neutron Activation Analysis (INAA), X-Ray Fluorescence (dispersive and total reflection) and other techniques. Simultaneously, TSP and PM10 were determined by gravimetry. Annual radon gas concentration was determined with passive electret system (type E-PERM) and short radon decay products with a continuous working level monitor. This work presents the distribution an evolution of metallic pollutants in the MZMV. The effective equivalent dose for radon, calculated by the measured annual mean values of Radon and its short decay products, are 1.233 mSvy -1 in good agreement with the world average reported by UNSCEAR of 1.3 mSvy -1 . Despite of substantial progress in elimination of Lead sources (primarily from the phase-out leaded gasoline and regulations to reduce motorized traffic as part of stricter environmental laws) well correlated with a dramatic diminution of 91% in the geometric mean (2.00 μg dL -1 compared with that of 1980, 22.2 μg dL -1 ), the risk of Lead exposure is stilI present. Besides, TSP and PM10 concentration continue at levels above annual average concentration specified in the Mexican Norm. It makes necessary the continuity in efforts targeted to diminish the pollution and also epidemiological studies to relate its effects on population health and suggest guidelines. (Author)

  1. Direct Penetrating Radiation Monitoring Systems: Technical Evaluation for Use at Area G, Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    D. Kraig; W. A. Treadaway; R. J. Wechsler

    1999-01-01

    Recent advances and commercialization of electret-ion-chamber (EIC) technology for photon measurements prompted us to consider EKs as a replacement for our TLD system. After laboratory tests indicated that both systems gave adequate results for controlled exposures, throughout 1998 we conducted field tests with paired TLDs and EICS, in LANL technical areas and in public areas. We had approximately 30 paired sampling sites at Area G. At each sampling site, we deployed three TLDs and three EICS. The EICS were contained in air-tight jars, each of which was placed in a Tyvek envelope and hung about 1 m above the ground. The dosimeters were read (and, if necessary, replaced) every three months. At the sites outside Area G, the TLD readings for the first two quarters were statistically significantly higher than those of the EICS: group average exposures were 38 and 36, compared with 33 mR (both quarters) for the EICS; during quarter 3, the EIC average (40 mR) was higher than the TLD average (34 mR); and during quarter 4, the two systems were statistically the same: EIC = 42, TLD = 41 with a p-value of 0.61. We are still evaluating these differences and performing additional laboratory studies to determine causes. At the Area G sites,we noticed that several of the TLDs gave much higher readings than their co-located EICS; we believe that the TLDs were over-responding by ∼50% to the low-energy (60-keV) gamma radiation associated with 241 Am, whereas the EICS were responding accurately. We conclude that EICS are more accurate at a wide range of gamma energies and are preferable to TLDs in environments where a significant fraction of the photons are low energy

  2. Radon remedial actions in schools of Friuli Venezia Giulia region (NE Italy)

    International Nuclear Information System (INIS)

    Giovani, C.; Cappelletto, C.; Garavaglia, M.; Pividore, S.; Villalta, R.

    2004-01-01

    In the last four years the Regional Agency of Environmental Protection (ARPA) of Friuli Venezia Giulia carried out a survey to determine the radon concentration in the schools of the area. During the survey all the 1320 schools and kindergartens of the region were investigated with more than 5000 measurements. In about 2% of cases, radon concentrations exceeded the reference levels of Italian law and remedial actions were performed. In collaboration with the Building Engineering Department of Udine University, ARPA FVG edited a manual concerning indications and proposals for building protection against radon. The environmental physics section of ARPA FVG, was heavily involved in the remedial action, both in the design of the action and in the investigation of effectiveness. In more than 20 schools the owners following ARPA indications solved the problem of high radon concentrations. In this paper the authors report the main type of applied remedial actions grouped taking into account the different remedial methodology. In Friuli Venezia Giulia region the main radon source is represented by soil. The contribution of building materials to high radon concentrations is negligible. The most common remedial actions consisted in natural or artificial depressurization of the soil or the crawlspace with respect to indoor building. Sometimes air was pumped into the building or air exchange number was increased. The authors show in detail the design of the performed investigations: these involved different measurement sets with passive electrets and active instruments for continuous data collection. Measurements usually last 3 contiguous weeks and are followed by long period measurements with solid track detectors. Optimization of remedial action performance was investigated when remedial action consisted in active air extraction from the soil under the buildings and fan time regulation was possible. Very often simple and cheap actions allowed a reduction of 90% in radon

  3. 222Rn Measurements in Dwellings of Argentina

    International Nuclear Information System (INIS)

    Gnoni, G.; Canoba, A.; Czerniczyniec, M.

    2011-01-01

    Radon gas ( 222 Rn) is responsible of about fifty per cent of the world population dose due to natural sources, being the most important pathway the inhalation of radon progeny, specially indoors. Radon concentration has been measured in dwellings at different locations in Argentina. The places selected to be evaluated are representative of the different geologic zones of the country. Near 3000 dwellings have been analyzed since 1983 up today. The measuring methods used in this case were track etched detectors, electrets and detectors based on activated charcoal adsorption. Two different methods with track etched detectors were used: a simple one, which determines only the average radon concentration, and a second one that measures both radon concentration and the equilibrium factor (F) between radon and its daughters. The last one is a method that uses two Makrofol passive track detectors in the same device. The average radon concentration value obtained from all the dwellings evaluated was 44.2 Bq.m-3. The annual effective dose calculated from this average concentration, using a dosimetric factor of 25 μSv.a- 1. (Bq.m -3 ) -1 , which assumes an equilibrium factor of 0.4, was 1.11 mSv. The average value obtained from the 222 dwellings evaluated by the second method was 49.3 Bq.m -3 and 0,37 the equilibrium factor, resulting the annual effective dose estimated 1,44 mSv. The measured equilibrium factor of 0,37 allows us to verify the assumed equilibrium factor of 0,4. Finally, radon levels in dwellings of Argentina are within the acceptable values for population, not being necessary to implement remedial actions, except in isolate cases that are still under study. (authors)

  4. The suitability of short-term measurements of radon in the built environment

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Phillips, P.S.; Crockett, R.G.M.; Woolridge, A.C.

    2008-01-01

    Although domestic and workplace radon concentration levels often show marked diurnal/short-term variation, overall health risk is determined by the long-term average level, and many national protocols advocate the use of long exposure periods, usually three months, to assess long-term risk. Simple passive measurement techniques, e.g. track-etch, activated charcoal and electret, can, however, provide reasonably accurate determinations with exposures as short as one week, and there is pressure from users and stake holders for assessments within this time period. We report evaluation of the effectiveness of one-week, one-month and three-month exposures over a period of one year in a designated Radon Affected Area in the United Kingdom (UK). Although short-term exposures did not compromise measurement accuracy, short-term radon variability rendered one-week measurements less reliable in predicting annual average radon levels via the conventional methodology. Analysis permitted estimation of the maximum and minimum short-term measured domestic radon concentrations at which there was 95% probability of the predicted annual average being below or above the UK Action Level of 200 Bq·m -3 respectively. Between these limits, the short-term result is equivocal, requiring repetition, and the 'equivocal range' for one-week measurements is significantly wider than for three-month exposures. In any geographical area, domestic radon concentrations are distributed log normally, with many properties having low average levels; a small number exhibit excessive levels, and this distribution must be considered when defining exposures for a radon measurement programme. In low-radon areas, where 1% of houses might exceed the Action Level, a one-week assessment will find that fewer outcomes are equivocal. For high-radon areas, with 20% or more houses over the Action Level, more than 50% of one-week outcomes will be equivocal, requiring repeats. The results of this work will be presented

  5. Radiological Programs- Ambient Radon at the Yucca Mountain Site (SCPB:NA)

    International Nuclear Information System (INIS)

    TRW

    1999-01-01

    This report summarizes the results of the ambient radon monitoring activities conducted by the Radiological/Environmental Field Programs Department of the Civilian Radioactive Waste Management and Operating Contractor (CRWMS M and O), Yucca Mountain Site Characterization Office. Overall, outdoor radon concentrations measured at the Yucca Mountain site were within the range of those reported for other areas in Nevada and the continental United States. Though there was some evidence of trends with time at some monitoring sites, regional atmospheric radon concentrations to date, do not appear to have changed significantly since the inception of site characterization activities. A preliminary dose assessment yielded an estimated annual effective dose equivalent of 134 mrem based on a continuous exposure to the average ambient radon concentration measured at the Yucca Mountain site. Concentrations were measured using two types of systems, passive electret ion chambers (EIC) and continuous radon monitors (CRM). The EICs produced time-averaged radon concentration data and the CRMs were used to study radon fluctuations over time. Between 1991 and 1995, the mean radon concentration at the site, as measured by EICs placed one meter above ground level, was 0.32 ± 0.15 pCi L -1 . Radon concentrations varied between monitoring locations and between years. Station NF38, located near the North Portal of the Exploratory Studies Facility (ESF), exhibited the highest overall average radon concentration at 0.55 pCi L -1 (1992 to 1995). Concentrations appear to cycle diurnally, generally peaking in the early morning hours and being lowest in the afternoon. The data also suggested that radon concentrations may fluctuate seasonally. The work accomplished between 1991 and 1995, established radon levels in the general area surrounding Yucca Mountain. It is recommended that further work focus directly on those locations that have the greatest potential for influencing ambient radon levels

  6. Natural radionuclides in Brazilian underground mines

    International Nuclear Information System (INIS)

    Santos, Talita de Oliveira

    2015-01-01

    Rock, soil and water contain "2"3"8U and "2"3"2Th and their decay products. The distribution of these radionuclides differs in terms of activity concentration depending on the mineral type and origin. All ore processing releases long and short half-life radionuclides, mainly radon and its progeny. It is important to monitor this gas and its decay products in underground mines in order to assess the radiological hazards of the exposed workers. On this concern, the present work outlines the characterization of brazilian underground mines with relation to natural radionuclides, specially radon and its progeny. The radon concentration was measured by using E-PERM Electrets Ion Chamber (Radelec), AlphaGUARD (Saphymo GmbH) and CR-39 (Landauer) track etch detectors. The radon progeny was determined by using DOSEman detector. The equilibrium state between radon and its progeny was calculated. Based on these data, the total effective dose for miners was estimated. Moreover, the contribution from the main sources to the radon level inside mines was evaluated. For this, the following detectors were used: measurements of radon concentrations in soil gas were carried out by using AlphaGUARD detector; "2"2"6Ra ("2"1"4Bi), "2"3"2Th e "4"0K specific activity in ore and soil samples were determined by using gamma-ray spectrometry HPGe detector (Canberra); and radon concentration in groundwater samples was performed by using RAD7 (Durridge Inc.). The radon concentration ranged from 113 to 8171 Bq.m"-"3 and the Equilibrium Equivalent Concentration varied from 76 to 1174 Bq.m"-"3. The equilibrium factor mean value was 0.4 (0.2 -0.7). The workers estimated total effective dose ranged from 1 to 22 mSv.a"-"1 (mean 10 mSv.a"-"1). Therefore, results show the importance to assess continually and permanently the radon and its progeny behavior and the need to adopt safety measurements against natural radiation in underground mines environment. (author)

  7. The design and fabrication of highly piezoelectric polymeric composites and their use in responsive devices

    Science.gov (United States)

    Baur, Cary Allen

    In this work, novel approaches to the design of highly piezoelectric and flexible polymer composites were explored. Diverging from past work focused on the addition of piezoelectric particles into polymer matrices, this research explores the ability to increase the piezoelectric performance of a host polymer through the incorporation of charge via polarizable, organic particles. The ability to insert charge into polymers, known as electrets, is well documented but widely considered impractical because of the low lifetime and temperature resistance of the inserted charge. Through the addition of particles that are polarizable, charge can be inserted into a system in a stable manner that results in highly charged materials with long lifetimes. Here, carbon structures, such as Buckminsterfullerenes (C60) and single-walled nanotubes (SWNTs), were composited into poly(vinylidene difluoride) at very low loading levels (0.05-0.25 wt%), resulting in the ability to insert stable charge into the system. We show that these highly charged systems can result in a doubling of the piezoelectric response of the host polymer when optimized. The low amount of nanoparticle filler required to improve these materials allows for the advantageous properties of the polymer matrix such as flexibility and compliance to be preserved, enabling highly piezoelectric and flexible system. This dissertation outlines research efforts towards the design and fabrication of 1) polymer composites with high piezoelectric response, 2) piezoelectric composites with increased operating temperatures, 3) motion control devices that incorporate piezoelectric materials and shape memory polymers, and 4) artificial muscles with piezoelectric polymers. The piezoelectric polymer composites developed in this work have potential to be utilized as highly efficient, flexible energy harvesters that can be used to capture ambient energy from environmental vibrations and motion from the human body. As actuators, these

  8. Distribution of radon concentration in residences and others buildings of Belo Horizonte city, MG, Brazil

    International Nuclear Information System (INIS)

    Santos, Talita de Oliveira

    2010-01-01

    Human beings are exposed to ionizing radiation from many natural sources. Radon and its progeny have been recognized as the most important contributors to the natural radioactivity dose, accounting for about half of all human exposure to ionizing radiation. Radon is a α-radioactive noble gas derived from the natural series of uranium and thorium, which occurs in a wide concentration range in all geological materials, especially, in rocks, soils and waters. By diffusion and convection, radon migrates from the rocks and soils to atmosphere and through fissures, pipes and holes it may enter the dwellings and other buildings. Another important radon source in dwellings is its emanation from the construction material. The radon progeny concentration in dwellings has been receiving considerable global attention due to its potential effect in causing lung cancer if it deposited in upper respiratory tract when inhaled. This work presents radon concentration distribution in dwellings in Metropolitan Region of Belo Horizonte - RMBH. The geological settings of the area are Archean rocks of Granitic Gneissic Complex and of metasediments sequences of the great Precambrian unit of the Iron Quadrangle of Minas Gerais, Brazil. Radon concentration measurements were carried out with continuous detector AlphaGUARD PQ200PRO (Genitron), in passive mode and with passive detectors E-PERM Electrets Ion Chamber-EIC. The radon progeny concentration was carried out with a solid state alpha spectroscope, the DOSEman PRO (Sarad). It was found an indoor radon concentration varying in a large range from 4 to 2664,0 Bq.m"-"3, with an average value of 108.0 Bq.m"-"3, median of 70 Bq.m"-"3, geometric mean equal to 76 Bq.m"-"3 and standard deviation of 170 Bq.m"-"3. About 15% of the results are over the United States Environmental Protection Agency (U.S. EPA) actions level, which is 148 Bq.m"-"3.The equilibrium factor between radon and its progeny were determined in dwellings, as 0.3 in average

  9. Computerised respiratory sounds can differentiate smokers and non-smokers.

    Science.gov (United States)

    Oliveira, Ana; Sen, Ipek; Kahya, Yasemin P; Afreixo, Vera; Marques, Alda

    2017-06-01

    Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, however it is unknown if it is able to detect changes in the lungs of healthy smokers. This study investigated the differences between computerised respiratory sounds of healthy smokers and non-smokers. Healthy smokers and non-smokers were recruited from a university campus. Respiratory sounds were recorded simultaneously at 6 chest locations (right and left anterior, lateral and posterior) using air-coupled electret microphones. Airflow (1.0-1.5 l/s) was recorded with a pneumotachograph. Breathing phases were detected using airflow signals and respiratory sounds with validated algorithms. Forty-four participants were enrolled: 18 smokers (mean age 26.2, SD = 7 years; mean FEV 1 % predicted 104.7, SD = 9) and 26 non-smokers (mean age 25.9, SD = 3.7 years; mean FEV 1 % predicted 96.8, SD = 20.2). Smokers presented significantly higher frequency at maximum sound intensity during inspiration [(M = 117, SD = 16.2 Hz vs. M = 106.4, SD = 21.6 Hz; t(43) = -2.62, p = 0.0081, d z  = 0.55)], lower expiratory sound intensities (maximum intensity: [(M = 48.2, SD = 3.8 dB vs. M = 50.9, SD = 3.2 dB; t(43) = 2.68, p = 0.001, d z  = -0.78)]; mean intensity: [(M = 31.2, SD = 3.6 dB vs. M = 33.7,SD = 3 dB; t(43) = 2.42, p = 0.001, d z  = 0.75)] and higher number of inspiratory crackles (median [interquartile range] 2.2 [1.7-3.7] vs. 1.5 [1.2-2.2], p = 0.081, U = 110, r = -0.41) than non-smokers. Significant differences between computerised respiratory sounds of smokers and non-smokers have been found. Changes in respiratory sounds are often the earliest sign of disease. Thus, computerised respiratory sounds

  10. Measurements of 222 Rn in the indoor of dwellings in the Argentinean Republic

    International Nuclear Information System (INIS)

    Canoba, A.; Lopez, F.

    2006-01-01

    The 222 Rn is responsible for approximately half of the dose in the population resultant of the exposure to natural radiation. Most of this dose comes from the inhalation of the offspring of the 222 Rn, and these doses they are specially important in set closed. The concentration of gas radon has been measured in housings of different cities of the Argentinean Republic. The elected cities are representative of the different geologic areas of our territory. For this its were used as detecting measurement method of nuclear tracks, electret detectors and detectors based on the adsorption in activated coal. Its were analyzed a total of 2689 housings from 1983 to the date. The average value of the radon concentration obtained starting from the 2689 monitored housings was of 41.6 Bq.m -3 . The effective annual dose calculated starting from this radon concentration, using a dosimetric factor of 25 μSv.a -1 (Bq.m -3 ), which assumes an equilibrium factor of 0.4, was of 1.04 mSv. Also, with the objective of determining the dose in form more exact, during the year 2000 it put on to point a passive technique for the simultaneous measurement such the radon concentration like of the equilibrium factor. This technique uses in oneself device two detectors of nuclear traces. The average value obtained starting from 204 monitored housings by this method of simultaneous measurement turns out to be 47.1 Bq.m -3 and 0.36 the equilibrium factor, being obtained a value of effective annual dose of 1.38 mSv. It fits to highlight that are very few the values above 200 Bq.m -3 and in any case the 300 Bq.m -3 is overcome. Analyzing the average equilibrium factor measured of 0.36, it was concluded that having assumed an equilibrium factor of 0.4 was adequate, for what for great measurement campaigns it can continue using the simple method that determines only the radon concentration. Comparing the obtained results by both methods, although the first counts with a statistic more important

  11. Measurements of {sup 222} Rn in the indoor of dwellings in the Argentinean Republic; Mediciones de {sup 222} Rn en el interior de viviendas de la Republica Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Canoba, A.; Lopez, F. [Autoridad Regulatoria Nuclear, Av. Del Libertador 8250 Ciudad de Buenos Aires (1429) (Argentina)]. e-mail: acanoba@cae.arn.gov.ar

    2006-07-01

    The {sup 222} Rn is responsible for approximately half of the dose in the population resultant of the exposure to natural radiation. Most of this dose comes from the inhalation of the offspring of the {sup 222} Rn, and these doses they are specially important in set closed. The concentration of gas radon has been measured in housings of different cities of the Argentinean Republic. The elected cities are representative of the different geologic areas of our territory. For this its were used as detecting measurement method of nuclear tracks, electret detectors and detectors based on the adsorption in activated coal. Its were analyzed a total of 2689 housings from 1983 to the date. The average value of the radon concentration obtained starting from the 2689 monitored housings was of 41.6 Bq.m{sup -3}. The effective annual dose calculated starting from this radon concentration, using a dosimetric factor of 25 {mu}Sv.a{sup -1} (Bq.m{sup -3}), which assumes an equilibrium factor of 0.4, was of 1.04 mSv. Also, with the objective of determining the dose in form more exact, during the year 2000 it put on to point a passive technique for the simultaneous measurement such the radon concentration like of the equilibrium factor. This technique uses in oneself device two detectors of nuclear traces. The average value obtained starting from 204 monitored housings by this method of simultaneous measurement turns out to be 47.1 Bq.m{sup -3} and 0.36 the equilibrium factor, being obtained a value of effective annual dose of 1.38 mSv. It fits to highlight that are very few the values above 200 Bq.m{sup -3} and in any case the 300 Bq.m{sup -3} is overcome. Analyzing the average equilibrium factor measured of 0.36, it was concluded that having assumed an equilibrium factor of 0.4 was adequate, for what for great measurement campaigns it can continue using the simple method that determines only the radon concentration. Comparing the obtained results by both methods, although the first

  12. What did we learn from the Austrian radon project?

    International Nuclear Information System (INIS)

    Friedmann, H.

    2004-01-01

    Approximately 40000 measurements of indoor radon concentrations were performed in randomly selected homes during the Austrian Radon Project. These measurements were carried out by using long-term measuring devices (SSNTD and Electret detectors) and short-term charcoal detectors with liquid scintillation counting as the method of analysis. In addition to the equilibrium factor, soil gas measurements and quasi-continuous indoor measurements, parallel-measurements with different detector systems in randomly selected homes were also performed. Very different results were occasionally obtained for one and the same room at the same time. This was so not only when comparing the long-term and short-term measuring devices; actually, different long-term detector systems also often showed significant discrepancies in results, although all detector systems had been carefully calibrated and tested in laboratories. The essential conclusion was that during a longer exposure in randomly selected homes, the detectors may be moved, opened, or handled in other unfavourable ways which introduce additional uncertainties in the measuring results. The aim of the Austrian Radon Project was to estimate the radon risk for geographic areas (municipalities). This task is different from the evaluation of the mean radon concentration in a single home. Generally, while long-term measurements (a year or even longer) are necessary to get reliable results for a particular house, this is not so where only the mean indoor radon concentrations for an area are of interest. Observed indoor radon concentrations give information about the actual radon exposures of the inhabitants but not about the radon risk from the ground. The house type, the way the house is constructed, the storey where people live, and some living patterns (ventilation rate etc.) modify the geological risk significantly, although it is the geological situation that has to be primarily taken into account when planning and constructing

  13. Characterization of deep level defects and thermally stimulated depolarization phenomena in La-doped TlInS2 layered semiconductor

    International Nuclear Information System (INIS)

    Seyidov, MirHasan Yu.; Suleymanov, Rauf A.; Mikailzade, Faik A.; Kargın, Elif Orhan; Odrinsky, Andrei P.

    2015-01-01

    deep level defects, are aligned in the direction of the applied electric field and the equilibrium polarization can be reached in a relatively short time. When the polarization field is maintained, while cooling the temperature of sample to a sufficiently low degrees, the relaxation times of the aligned dipoles drastically increases. Practically, frozen internal electric field or electrets states remain inside the TlInS 2 :La when the applied bias field is switched off. The influence of deep level defects on TSDC spectra of TlInS 2 :La has been revealed for the first time

  14. Characterization of deep level defects and thermally stimulated depolarization phenomena in La-doped TlInS{sub 2} layered semiconductor

    Energy Technology Data Exchange (ETDEWEB)

    Seyidov, MirHasan Yu., E-mail: smirhasan@gyte.edu.tr; Suleymanov, Rauf A.; Mikailzade, Faik A. [Department of Physics, Gebze Technical University, Gebze, Kocaeli 41400 (Turkey); Institute of Physics of NAS of Azerbaijan, H. Javid ave. 33, Baku AZ-1143 (Azerbaijan); Kargın, Elif Orhan [Department of Physics, Gebze Technical University, Gebze, Kocaeli 41400 (Turkey); Odrinsky, Andrei P. [Institute of Technical Acoustics, National Academy of Sciences of Belarus, Lyudnikov ave. 13, Vitebsk 210717 (Belarus)

    2015-06-14

    , which are originated from the charged B5 deep level defects, are aligned in the direction of the applied electric field and the equilibrium polarization can be reached in a relatively short time. When the polarization field is maintained, while cooling the temperature of sample to a sufficiently low degrees, the relaxation times of the aligned dipoles drastically increases. Practically, frozen internal electric field or electrets states remain inside the TlInS{sub 2}:La when the applied bias field is switched off. The influence of deep level defects on TSDC spectra of TlInS{sub 2}:La has been revealed for the first time.

  15. PREFACE: Dielectrics 2009: Measurement Analysis and Applications

    Science.gov (United States)

    Vaughan, Alun; Williams, Graham

    2009-07-01

    2001 the Annual Meetings focused on numerous topics, including relaxation and conduction processes in liquids, solids, liquid crystals, synthetic polymers and biopolymers, piezoelectric materials, electrets and ferroelectrets, interfacial phenomena, high field conduction and breakdown phenomena in solids, liquids and gases and, importantly, the remarkable developments in dielectric instrumentation during this period. These activities reflected the need, and willingness, to move dielectrics researches with the times. As examples of the variety and diversity of these meetings we may refer briefly to the 1981, 1989 and 1996 Meetings. The 1981 Oxford Meeting on High Field Phenomena in Dielectrics included strong themes on fundamental and practical effects of high E-fields on the dielectric and conduction behaviour of liquids and solids, electrical treeing and dielectric breakdown, non-linear dielectric effects, electrets, thin-film devices and electro-rheology. The late 1980's had seen large initiatives in the UK and globally in the general area of Molecular Electronics so, in timely fashion, this was the subject of the 1989 Meeting in Bangor. The 1996 Smart Dielectrics Meeting at Canterbury reported subsequent advances in designer materials having electro-responsive and electro-optical properties. The programme concerned electro- and photo-active materials, mainly organic, in the form of polar dielectrics, polyelectrolytes, organic semi- and photo-conductors, photo-refractive polymer films, organic ferroelectric films, liquid crystalline polymer films, piezo- and pyro-electric polymer films, electroluminescent polymers, electro-rheological fluids and non-linear optical polymer films as described by leading international scientists. The physico-chemical functions of the materials were demonstrated and interpreted in terms of fundamental molecular properties. An Archive, containing full details of all the Meetings of the DDG and the Dielectrics Society, has been placed on

  16. EDITORIAL: Selected papers from the 10th International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS 2010) Selected papers from the 10th International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS 2010)

    Science.gov (United States)

    Reynaerts, Dominiek; Vullers, Ruud

    2011-10-01

    collaboration with the staff of IOP Publishing. PowerMEMS 2010 contents Harvesting energy from airflow with a michromachined piezoelectric harvester inside a Helmholtz resonator S P Matova, R Elfrink, R J M Vullers and R van Schaijk Analysis and characterization of triangular electrode structures for electrostatic energy harvestingDaniel Hoffmann, Bernd Folkmer and Yiannos Manoli A smart and self-sufficient frequency tunable vibration energy harvesterC Eichhorn, R Tchagsim, N Wilhelm and P Woias Power output enhancement of a vibration-driven electret generator for wireless sensor applicationsTatsuakira Masaki, Kenji Sakurai, Toru Yokoyama, Masayo Ikuta, Hiroshi Sameshima, Masashi Doi, Tomonori Seki and Masatoshi Oba Harvesting traffic-induced vibrations for structural health monitoring of bridgesT V Galchev, J McCullagh, R L Peterson and K Najafi Dispenser-printed planar thick-film thermoelectric energy generatorsA Chen, D Madan, P K Wright and J W Evans Silicon nanowire arrays as thermoelectric material for a power microgeneratorD Dávila, A Tarancón, M Fernández-Regúlez, C Calaza, M Salleras, A San Paulo and L Fonseca A micro thermal switch with a stiffness-enhanced thermal isolation structureTakashiro Tsukamoto, Masayoshi Esashi and Shuji Tanaka A dielectric liquid contact thermal switch with electrowetting actuationA R McLanahan, C D Richards and R F Richards A self-regulating valve for single-phase liquid cooling of microelectronicsRadu Donose, Michaël De Volder, Jan Peirs and Dominiek Reynaerts A MEMS-enabled 3D zinc-air microbattery with improved discharge characteristics based on a multilayer metallic substructureA Armutlulu, Y Fang, S H Kim, C H Ji, S A Bidstrup Allen and M G Allen Design, fabrication and testing of an air-breathing micro direct methanol fuel cell with compound anode flow fieldLuwen Wang, Yufeng Zhang, Youran Zhao, Zijiang An, Zhiping Zhou and Xiaowei Liu A shadow-mask evaporated pyroMEMS igniterD A de Koninck, D Briand and N F de Rooij Aerodynamic

  17. Environmentally-safe pest control using novel bioelectrostatic techniques: Initial results and prospects for area-wide usage

    International Nuclear Information System (INIS)

    Howse, P.E.; Underwood, K.L.

    2000-01-01

    The aim of our work is to provide an alternative to broad-scale pesticide spraying for crop protection. The need for such a development, in order to protect the environment, wildlife and human health, has never been more urgent. The project was conceived in 1992 deriving from concepts which are the subject of patent applications in 60 countries throughout the world. Since then, feasibility studies have been completed and links have been made with other organisations keen to evaluate and develop the technique. A parallel project, using similar electrostatic powder technology, was the development of an environmentally-friendly cockroach trap, which received a Prince of Wales Award for Innovation in 1997. In order to hasten the commercialisation of the technology, a new company, ExoSect Ltd, has been set up in association with the University of Southampton. The technique is based on the discovery that certain inert powders that can be electrostatically charged will adhere to the insect cuticle. The cuticle appears to be permanently electrically polarised (i.e., it functions as an electret). Powders of opposite polarity to the surface will therefore attach readily and it is extremely difficult for the insect to dislodge itself. In contrast, powders which do not charge easily or which rapidly lose their charge, quickly fall off, or can be groomed off by the insect. Male insects are lured to a source of charged powder by odour attractants (e.g., sexual pheromones). They then contaminate themselves with the powder. After leaving the trap, they pass on the powder to females in mating attempts. An insecticidal material formulated with the powder can thus be delivered to the females. The insecticide must be slow-acting in order for this transfer to take place. The components of the method are the following: Carrier Particles There are various inert or biodegradable materials with appropriate electrostatic characteristics which can be used as carriers for other biologically