WorldWideScience

Sample records for elastomeric patch derived

  1. The effects of platelet lysate patches on the activity of tendon-derived cells.

    Science.gov (United States)

    Costa-Almeida, Raquel; Franco, Albina R; Pesqueira, Tamagno; Oliveira, Mariana B; Babo, Pedro S; Leonor, Isabel B; Mano, João F; Reis, Rui L; Gomes, Manuela E

    2018-03-01

    Platelet-derived biomaterials are widely explored as cost-effective sources of therapeutic factors, holding a strong potential for endogenous regenerative medicine. Particularly for tendon repair, treatment approaches that shift the injury environment are explored to accelerate tendon regeneration. Herein, genipin-crosslinked platelet lysate (PL) patches are proposed for the delivery of human-derived therapeutic factors in patch augmentation strategies aiming at tendon repair. Developed PL patches exhibited a controlled release profile of PL proteins, including bFGF and PDGF-BB. Additionally, PL patches exhibited an antibacterial effect by preventing the adhesion, proliferation and biofilm formation by S. aureus, a common pathogen in orthopaedic surgical site infections. Furthermore, these patches supported the activity of human tendon-derived cells (hTDCs). Cells were able to proliferate over time and an up-regulation of tenogenic genes (SCX, COL1A1 and TNC) was observed, suggesting that PL patches may modify the behavior of hTDCs. Accordingly, hTDCs deposited tendon-related extracellular matrix proteins, namely collagen type I and tenascin C. In summary, PL patches can act as a reservoir of biomolecules derived from PL and support the activity of native tendon cells, being proposed as bioinstructive patches for tendon regeneration. Platelet-derived biomaterials hold great interest for the delivery of therapeutic factors for applications in endogenous regenerative medicine. In the particular case of tendon repair, patch augmentation strategies aiming at shifting the injury environment are explored to improve tendon regeneration. In this study, PL patches were developed with remarkable features, including the controlled release of growth factors and antibacterial efficacy. Remarkably, PL patches supported the activity of native tendon cells by up-regulating tenogenic genes and enabling the deposition of ECM proteins. This patch holds great potential towards

  2. An elastomeric grating coupler

    NARCIS (Netherlands)

    Kocabas, A.; Ay, F.; Dana, A.; Aydinli, A.

    We report on a novel nondestructive and reversible method for coupling free space light to planar optical waveguides. In this method, an elastomeric grating is used to produce an effective refractive index modulation on the surface of the optical waveguide. The external elastomeric grating binds to

  3. Automated patch clamp on mESC-derived cardiomyocytes for cardiotoxicity prediction.

    Science.gov (United States)

    Stoelzle, Sonja; Haythornthwaite, Alison; Kettenhofen, Ralf; Kolossov, Eugen; Bohlen, Heribert; George, Michael; Brüggemann, Andrea; Fertig, Niels

    2011-09-01

    Cardiovascular side effects are critical in drug development and have frequently led to late-stage project terminations or even drug withdrawal from the market. Physiologically relevant and predictive assays for cardiotoxicity are hence strongly demanded by the pharmaceutical industry. To identify a potential impact of test compounds on ventricular repolarization, typically a variety of ion channels in diverse heterologously expressing cells have to be investigated. Similar to primary cells, in vitro-generated stem cell-derived cardiomyocytes simultaneously express cardiac ion channels. Thus, they more accurately represent the native situation compared with cell lines overexpressing only a single type of ion channel. The aim of this study was to determine if stem cell-derived cardiomyocytes are suited for use in an automated patch clamp system. The authors show recordings of cardiac ion currents as well as action potential recordings in readily available stem cell-derived cardiomyocytes. Besides monitoring inhibitory effects of reference compounds on typical cardiac ion currents, the authors revealed for the first time drug-induced modulation of cardiac action potentials in an automated patch clamp system. The combination of an in vitro cardiac cell model with higher throughput patch clamp screening technology allows for a cost-effective cardiotoxicity prediction in a physiologically relevant cell system.

  4. Patch-Clamp Recording from Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes: Improving Action Potential Characteristics through Dynamic Clamp

    Science.gov (United States)

    Veerman, Christiaan C.; Zegers, Jan G.; Mengarelli, Isabella; Bezzina, Connie R.

    2017-01-01

    Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great promise for studying inherited cardiac arrhythmias and developing drug therapies to treat such arrhythmias. Unfortunately, until now, action potential (AP) measurements in hiPSC-CMs have been hampered by the virtual absence of the inward rectifier potassium current (IK1) in hiPSC-CMs, resulting in spontaneous activity and altered function of various depolarising and repolarising membrane currents. We assessed whether AP measurements in “ventricular-like” and “atrial-like” hiPSC-CMs could be improved through a simple, highly reproducible dynamic clamp approach to provide these cells with a substantial IK1 (computed in real time according to the actual membrane potential and injected through the patch-clamp pipette). APs were measured at 1 Hz using perforated patch-clamp methodology, both in control cells and in cells treated with all-trans retinoic acid (RA) during the differentiation process to increase the number of cells with atrial-like APs. RA-treated hiPSC-CMs displayed shorter APs than control hiPSC-CMs and this phenotype became more prominent upon addition of synthetic IK1 through dynamic clamp. Furthermore, the variability of several AP parameters decreased upon IK1 injection. Computer simulations with models of ventricular-like and atrial-like hiPSC-CMs demonstrated the importance of selecting an appropriate synthetic IK1. In conclusion, the dynamic clamp-based approach of IK1 injection has broad applicability for detailed AP measurements in hiPSC-CMs. PMID:28867785

  5. Evaluation of Changes in Morphology and Function of Human Induced Pluripotent Stem Cell Derived Cardiomyocytes (HiPSC-CMs) Cultured on an Aligned-Nanofiber Cardiac Patch.

    Science.gov (United States)

    Khan, Mahmood; Xu, Yanyi; Hua, Serena; Johnson, Jed; Belevych, Andriy; Janssen, Paul M L; Gyorke, Sandor; Guan, Jianjun; Angelos, Mark G

    2015-01-01

    Dilated cardiomyopathy is a major cause of progressive heart failure. Utilization of stem cell therapy offers a potential means of regenerating viable cardiac tissue. However, a major obstacle to stem cell therapy is the delivery and survival of implanted stem cells in the ischemic heart. To address this issue, we have developed a biomimetic aligned nanofibrous cardiac patch and characterized the alignment and function of human inducible pluripotent stem cell derived cardiomyocytes (hiPSC-CMs) cultured on this cardiac patch. This hiPSC-CMs seeded patch was compared with hiPSC-CMs cultured on standard flat cell culture plates. hiPSC-CMs were cultured on; 1) a highly aligned polylactide-co-glycolide (PLGA) nanofiber scaffold (~50 microns thick) and 2) on a standard flat culture plate. Scanning electron microscopy (SEM) was used to determine alignment of PLGA nanofibers and orientation of the cells on the respective surfaces. Analysis of gap junctions (Connexin-43) was performed by confocal imaging in both the groups. Calcium cycling and patch-clamp technique were performed to measure calcium transients and electrical coupling properties of cardiomyocytes. SEM demonstrated >90% alignment of the nanofibers in the patch which is similar to the extracellular matrix of decellularized rat myocardium. Confocal imaging of the cardiomyocytes demonstrated symmetrical alignment in the same direction on the aligned nanofiber patch in sharp contrast to the random appearance of cardiomyocytes cultured on a tissue culture plate. The hiPSC-CMs cultured on aligned nanofiber cardiac patches showed more efficient calcium cycling compared with cells cultured on standard flat surface culture plates. Quantification of mRNA with qRT-PCR confirmed that these cardiomyocytes expressed α-actinin, troponin-T and connexin-43 in-vitro. Overall, our results demonstrated changes in morphology and function of human induced pluripotent derived cardiomyocytes cultured in an anisotropic environment

  6. Development of a flameproof elastic elastomeric fiber

    Science.gov (United States)

    Howarth, J. T.; Nilgrom, J.; Massucco, A.; Sheth, S. G.; Dawn, F. S.

    1971-01-01

    Various flexible polyurethane structures containing halogen were synthesized from polyesters derived from aliphatic or aromatic polyols and dibasic acids. Aliphatic halide structures could not be used because they are unstable at the required reaction temperatures, giving of hydrogen halide which hydrolyzes the ester linkages. In contract, halogen-containing aromatic polyols were stable and satisfactory products were made. The most promising composition, a brominated neopentyl glycol capped with toluene disocyanate, was used as a conventional diisocyanate, in conjunction with hydroxy-terminated polyethers or polyesters to form elastomeric urethanes containing about 10% bromine with weight. Products made in this manner will not burn in air, have an oxygen index value of about 25, and have tensile strength values of about 5,000 psi at 450% elongation. The most efficient additives for imparting flame retardancy to Spandex urethanes are aromatic halides and the most effective of these are the bromide compounds. Various levels of flame retardancy have been achieved depending on the levels of additives used.

  7. Elastomeric Properties of Poly(glycerol sebacate) (PGS) Based Nanoparticle Composites

    Science.gov (United States)

    Chung, Hyun-Joong; Li, Xinda; Hong, Albert T.-L.

    2014-03-01

    Owing to the unique combination of biocompatible, biodegradable, and elastomeric properties, poly(glycerol sebacate) and their derivatives are an emerging class of biomaterials for soft tissue replacement, drug delivery, tissue adhesive, and hard tissue regeneration. The mechanical properties of the polyester have been tailored to match a wide range of target organs, ranging from cardiac muscle to bones, by manipulating the process parameters to modulate cross-linking density. In the present study, we applied nanoparticles and cross-linking agents to further optimize their elastomeric properties. Especially, the study aims to enhance the practically important, but less studied, property of tear resistance. Microscopic origin of the property enhancement is discussed.

  8. Fabrication of elastomeric silk fibers.

    Science.gov (United States)

    Bradner, Sarah A; Partlow, Benjamin P; Cebe, Peggy; Omenetto, Fiorenzo G; Kaplan, David L

    2017-09-01

    Methods to generate fibers from hydrogels, with control over mechanical properties, fiber diameter, and crystallinity, while retaining cytocompatibility and degradability, would expand options for biomaterials. Here, we exploited features of silk fibroin protein for the formation of tunable silk hydrogel fibers. The biological, chemical, and morphological features inherent to silk were combined with elastomeric properties gained through enzymatic crosslinking of the protein. Postprocessing via methanol and autoclaving provided tunable control of fiber features. Mechanical, optical, and chemical analyses demonstrated control of fiber properties by exploiting the physical cross-links, and generating double network hydrogels consisting of chemical and physical cross-links. Structure and chemical analyses revealed crystallinity from 30 to 50%, modulus from 0.5 to 4 MPa, and ultimate strength 1-5 MPa depending on the processing method. Fabrication and postprocessing combined provided fibers with extensibility from 100 to 400% ultimate strain. Fibers strained to 100% exhibited fourth order birefringence, revealing macroscopic orientation driven by chain mobility. The physical cross-links were influenced in part by the drying rate of fabricated materials, where bound water, packing density, and microstructural homogeneity influenced cross-linking efficiency. The ability to generate robust and versatile hydrogel microfibers is desirable for bottom-up assembly of biological tissues and for broader biomaterial applications. © 2017 Wiley Periodicals, Inc.

  9. Evaluation of Force Degradation Pattern of Elastomeric Ligatures and Elastomeric Separators in Active Tieback State

    Directory of Open Access Journals (Sweden)

    Amir Mohammadi

    2015-12-01

    Full Text Available Background and aims. The purpose of this study was to evaluate initial force and force decay of commercially available elastomeric ligatures and elastomeric separators in active tieback state in a simulated oral environment. Materials and methods. A total of 288 elastomeric ligatures and elastomeric separators from three manufacturers (Dentaurum, RMO, 3M Unitek were stretched to 100% and 150% of their original inner diameter. Force levels were measured initially and at 3-minute, 24-hour, and 1-, 2-, 3- and 4-week intervals. Data were analyzed by univariate analysis of variance and a post hoc Tukey test. Results. The means of initial forces of elastomeric ligatures and separators from three above-mentioned companies, when stretched to 100% of their inner diameters, were 199, 305 and 284 g, and 330, 416, 330 g; when they were stretched to 150% of their inner diameters the values were 286, 422 and 375 g, and 433, 540 and 504 g, respectively. In active tieback state, 11‒18% of the initial force of the specimens was lost within the first 3 minutes and 29‒63% of the force decay occurred in the first 24 hours; then force decay rate decreased. 62‒81% of the initial force was lost in 4 weeks. Although force decay pattern was identical in all the products, the initial force and force decay of Dentaurum elastomeric products were less than the similar products of other companies (P<0.05. Under the same conditions, the force of elastomeric separators was greater than elastomeric ligatures of the same company. Conclusion. Regarding the force pattern of elastomeric ligatures and separators and optimal force for tooth movement, many of these products can be selected for applying orthodontic forces in active tieback state.

  10. Chemical Stability of Telavancin in Elastomeric Pumps

    Directory of Open Access Journals (Sweden)

    Patrick Sand, MSc

    2015-12-01

    Conclusions: The results of this study indicate that telavancin remains chemically stable when diluted in the Intermate Infusion System and the Homepump Eclipse elastomeric pumps and stored at 2°C to 8°C for up to 8 days protected from light at the concentration range and dilution schemes evaluated.

  11. Tribologically modified surfaces on elastomeric materials

    NARCIS (Netherlands)

    Rodriguez, N.V.; Masen, Marc Arthur; Schipper, Dirk J.

    2013-01-01

    As the result of tribological loading, the properties of the surface of elastomeric materials will alter. This effect has been observed using SEM and EDS analysis of the tread of a used car tyre, where differences in structure between the substrate and the area near the surface were found. To study

  12. Biodegradable elastomeric scaffolds for soft tissue engineering

    NARCIS (Netherlands)

    Pêgo, A.P.; Poot, Andreas A.; Grijpma, Dirk W.; Feijen, Jan

    2003-01-01

    Elastomeric copolymers of 1,3-trimethylene carbonate (TMC) and ε-caprolactone (CL) and copolymers of TMC and D,L-lactide (DLLA) have been evaluated as candidate materials for the preparation of biodegradable scaffolds for soft tissue engineering. TMC-DLLA copolymers are amorphous and degrade more

  13. Tensile properties of orthodontic elastomeric ligatures.

    Science.gov (United States)

    Ahrari, F; Jalaly, T; Zebarjad, M

    2010-01-01

    Tensile properties of elastomeric ligatures become important when efficiency of orthodontic appliances is considered. The aim of this study was to compare tensile strength, extension to tensile strength, toughness and modulus of elasticity of elastomeric ligatures in both the as--received condition and after 28 days of immersion in the simulated oral environment. Furthermore, the changes that occurred in tensile properties of each brand of ligatures after 28 days were evaluated. Experimental-laboratory based. Elastomeric ligatures were obtained from different companies and their tensile properties were measured using Zwick testing machine in both the as-received condition and after 28 days of immersion in the simulated oral environment. The data were analyzed using independent sample t-tests, analysis of variance and Tukey tests. After 28 days, all the ligatures experienced a significant decrease in tensile strength, extension to tensile strength and toughness ( P tensile properties of different brands of ligatures in both conditions ( P tensile properties of different brands of ligatures, which should be considered during selection of these products.

  14. Flexible and Stretchable Microneedle Patches with Integrated Rigid Stainless Steel Microneedles for Transdermal Biointerfacing.

    Science.gov (United States)

    Rajabi, Mina; Roxhed, Niclas; Shafagh, Reza Zandi; Haraldson, Tommy; Fischer, Andreas Christin; Wijngaart, Wouter van der; Stemme, Göran; Niklaus, Frank

    2016-01-01

    This paper demonstrates flexible and stretchable microneedle patches that combine soft and flexible base substrates with hard and sharp stainless steel microneedles. An elastomeric polymer base enables conformal contact between the microneedle patch and the complex topography and texture of the underlying skin, while robust and sharp stainless steel microneedles reliably pierce the outer layers of the skin. The flexible microneedle patches have been realized by magnetically assembling short stainless steel microneedles into a flexible polymer supporting base. In our experimental investigation, the microneedle patches were applied to human skin and an excellent adaptation of the patch to the wrinkles and deformations of the skin was verified, while at the same time the microneedles reliably penetrate the surface of the skin. The unobtrusive flexible and stretchable microneedle patches have great potential for transdermal biointerfacing in a variety of emerging applications such as transdermal drug delivery, bioelectric treatments and wearable bio-electronics for health and fitness monitoring.

  15. Hydrogen isotope permeation in elastomeric materials

    International Nuclear Information System (INIS)

    Steinmeyer, R.H.; Braun, J.D.

    1976-01-01

    The permeabilities of elastomeric and polymeric materials to hydrogen isotopes were measured at room temperature. The technique for measuring permeation rates is based on the following constant-volume method: a fixed pressure of gas is applied to one side of the specimen to be studied and the permeability constant is determined from the observed rate of pressure increase in an initially evacuated volume on the other side of the specimen. Permeability constants for hydrogen, deuterium, and tritium were measured for Mylar, Teflon, Kapton, Saran, Buna-N, and latex rubber. Results were compared with literature values for hydrogen and deuterium where available and showed excellent agreement

  16. Evaluation of shear mounted elastomeric damper

    Science.gov (United States)

    Zorzi, E.; Walton, J.

    1982-01-01

    Viton-70 elastomeric shear mounted damper was built and tested on a T-55 power turbine spool in the rotor's high speed balancing rig. This application of a shear mounted elastomeric damper demonstrated for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear damper design was selected because it was compatible with actual gas turbine engine radial space constraints, could accommodate both the radial and axial thrust loads present in gas turbine engines, and was capable of controlled axial preload. The shear damper was interchangeable with the production T-55 power turbine roller bearing support so that a direct comparison between the shear damper and the production support structure could be made. Test results show that the Viton-70 elastomer damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing up to the maximum rotor speed of 16,000 rpm. Excellent correlation between the predicted and experienced critical speeds, mode shapes and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

  17. A Hybrid Model for Safety Pharmacology on an Automated Patch Clamp Platform: Using Dynamic Clamp to Join iPSC-Derived Cardiomyocytes and Simulations of Ik1 Ion Channels in Real-Time

    Directory of Open Access Journals (Sweden)

    Birgit Goversen

    2018-01-01

    Full Text Available An important aspect of the Comprehensive In Vitro Proarrhythmia Assay (CiPA proposal is the use of human stem cell-derived cardiomyocytes and the confirmation of their predictive power in drug safety assays. The benefits of this cell source are clear; drugs can be tested in vitro on human cardiomyocytes, with patient-specific genotypes if needed, and differentiation efficiencies are generally excellent, resulting in a virtually limitless supply of cardiomyocytes. There are, however, several challenges that will have to be surmounted before successful establishment of hSC-CMs as an all-round predictive model for drug safety assays. An important factor is the relative electrophysiological immaturity of hSC-CMs, which limits arrhythmic responses to unsafe drugs that are pro-arrhythmic in humans. Potentially, immaturity may be improved functionally by creation of hybrid models, in which the dynamic clamp technique joins simulations of lacking cardiac ion channels (e.g., IK1 with hSC-CMs in real-time during patch clamp experiments. This approach has been used successfully in manual patch clamp experiments, but throughput is low. In this study, we combined dynamic clamp with automated patch clamp of iPSC-CMs in current clamp mode, and demonstrate that IK1 conductance can be added to iPSC-CMs on an automated patch clamp platform, resulting in an improved electrophysiological maturity.

  18. Contact angle of unset elastomeric impression materials.

    Science.gov (United States)

    Menees, Timothy S; Radhakrishnan, Rashmi; Ramp, Lance C; Burgess, John O; Lawson, Nathaniel C

    2015-10-01

    Some elastomeric impression materials are hydrophobic, and it is often necessary to take definitive impressions of teeth coated with some saliva. New hydrophilic materials have been developed. The purpose of this in vitro study was to compare contact angles of water and saliva on 7 unset elastomeric impression materials at 5 time points from the start of mixing. Two traditional polyvinyl siloxane (PVS) (Aquasil, Take 1), 2 modified PVS (Imprint 4, Panasil), a polyether (Impregum), and 2 hybrid (Identium, EXA'lence) materials were compared. Each material was flattened to 2 mm and a 5 μL drop of distilled water or saliva was dropped on the surface at 25 seconds (t0) after the start of mix. Contact angle measurements were made with a digital microscope at initial contact (t0), t1=2 seconds, t2=5 seconds, t3=50% working time, and t4=95% working time. Data were analyzed with a generalized linear mixed model analysis, and individual 1-way ANOVA and Tukey HSD post hoc tests (α=.05). For water, materials grouped into 3 categories at all time-points: the modified PVS and one hybrid material (Identium) produced the lowest contact angles, the polyether material was intermediate, and the traditional PVS materials and the other hybrid (EXA'lence) produced the highest contact angles. For saliva, Identium, Impregum, and Imprint 4 were in the group with the lowest contact angle at most time points. Modified PVS materials and one of the hybrid materials are more hydrophilic than traditional PVS materials when measured with water. Saliva behaves differently than water in contact angle measurement on unset impression material and produces a lower contact angle on polyether based materials. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Kinetic analysis of elastomeric lag damper for helicopter rotors

    Science.gov (United States)

    Liu, Yafang; Wang, Jidong; Tong, Yan

    2018-02-01

    The elastomeric lag dampers suppress the ground resonance and air resonance that play a significant role in the stability of the helicopter. In this paper, elastomeric lag damper which is made from silicone rubber is built. And a series of experiments are conducted on this elastomeric lag damper. The stress-strain curves of elastomeric lag dampers employed shear forces at different frequency are obtained. And a finite element model is established based on Burgers model. The result of simulation and tests shows that the simple, linear model will yield good predictions of damper energy dissipation and it is adequate for predicting the stress-strain hysteresis loop within the operating frequency and a small-amplitude oscillation.

  20. Birth Control Patch

    Science.gov (United States)

    ... Health Food & Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Birth Control Patch KidsHealth / For Teens / Birth Control Patch What's ...

  1. Sleep Sleeping Patch

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The Sleep Sleeping Patch is a new kind of external patch based on modern sleep medicine research achievements, which uses the internationally advanced transdermal therapeutic system (TTS). The Sleep Sleeping Patch transmits natural sleep inducers such as peppermint and liquorice extracts and melatonin through the skin to induce sleep. Clinical research proves that the Sleep Sleeping Patch can effectively improve insomnia and the quality of sleep. Highly effective: With the modern TTS therapy,

  2. Electroactive polyurethane/siloxane derived from castor oil as a versatile cardiac patch, part I: Synthesis, characterization, and myoblast proliferation and differentiation.

    Science.gov (United States)

    Baheiraei, Nafiseh; Gharibi, Reza; Yeganeh, Hamid; Miragoli, Michele; Salvarani, Nicolò; Di Pasquale, Elisa; Condorelli, Gianluigi

    2016-03-01

    Tissue-engineered cardiac patch aims at regenerating an infarcted heart by improving cardiac function and providing mechanical support to the diseased myocardium. In order to take advantages of electroactivity, a new synthetic method was developed for the introduction of an electroactive oligoaniline into the backbone of prepared patches. For this purpose, a series of electroactive polyurethane/siloxane films containing aniline tetramer (AT) was prepared through sol-gel reaction of trimethoxysilane functional intermediate polyurethane prepolymers made from castor oil and poly(ethylene glycol). Physicochemical, mechanical, and electrical conductivity of samples were evaluated and the recorded results were correlated to their structural characteristics. The optimized films were proved to be biodegradable and have tensile properties suitable for cardiac patch application. The embedded AT moieties in the backbone of the prepared samples preserved their electroactivity with the electrical conductivity in the range of 10 -4 S/cm. The prepared films were compatible with proliferation of C2C12 and had potential for enhancing myotube formation even without external electrical stimulation. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 775-787, 2016. © 2015 Wiley Periodicals, Inc.

  3. Chemical Stability of Telavancin in Elastomeric Pumps☆

    Science.gov (United States)

    Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine

    2015-01-01

    Background VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. Objective To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Methods Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer’s Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. Results The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump

  4. Chemical Stability of Telavancin in Elastomeric Pumps.

    Science.gov (United States)

    Sand, Patrick; Aladeen, Traci; Kirkegaard, Paul; LaChance, Dennis; Slover, Christine

    2015-12-01

    VIBATIV is a once-daily, injectable lipoglycopeptide antibiotic approved in the U.S. for the treatment of hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) caused by susceptible isolates of Staphylococcus aureus when alternative treatments are not suitable. In addition, VIBATIV is approved in the U.S. for the treatment of adult patients with complicated skin & skin structure infections (cSSSI) caused by susceptible isolates of Gram-positive bacteria, including Staphylococcus aureus, both methicillin-susceptible (MSSA) and methicillin-resistant (MRSA) strains. To evaluate the chemical stability of telavancin (Vibativ; Theravance Biopharma US, Inc, Northbrook, Illinois), a lipoglycopeptide antibiotic with activity against methicillin-resistant Staphylococcus aureus, in 2 types of elastomeric pumps, the Intermate Infusion System (Baxter International Inc) and the Homepump Eclipse (I-Flow Corporation). Different sizes of the Baxter (Ontario, Canada) (105 mL and 275 mL) and I-Flow (Stoughton, Massachusetts) (100 mL and 250 mL) pumps were compared with glass controls. The telavancin drug product was reconstituted and diluted to concentrations of 0.6 mg/mL and 8.0 mg/mL using either 0.9% saline, 5% dextrose in water, or sterilized water for injection (0.6 mg/mL telavancin) or saline (8.0 mg/mL telavancin) followed by Ringer's Lactate solution. Pumps were filled and stored at 2°C to 8°C, protected from light. Aliquots from both pump types and for all telavancin reconstitution/dilution schemes and concentrations were taken over a period of 8 days and analyzed for appearance, pH, telavancin concentration and purity, and degradation products. The pH of all pump solutions remained consistent throughout the 8-day analysis period, within a range of 4.6 to 5.7 for the 0.6 mg/mL and 4.4 to 4.9 for the 8.0 mg/mL telavancin solutions. There was no significant change in the chromatographic purity for any of the pump solutions examined. All decreases in

  5. Unvulcanized elastomeric waterproofing materials for construction application

    Directory of Open Access Journals (Sweden)

    O. V. Karmanova

    2016-01-01

    Full Text Available In the construction was widespread elastomer profiles, which have the ability to swell in water. Such products should have a high capacity for swelling, elasticity, resistance to weathering. At the present time for these purposes are used materials, mostly of foreign origin. With the increasing pace of construction in Russia the problem of replacement of imported materials is particularly relevant. The work was dedicated to the creation of water-swellable elastomer materials using bentonite powders and study of their properties. Сomparative testing of imported and domestic hydrophilic sealants were held. Rationale and choice of components for the cords of bentonite was conducted. Polymer base is saturated ethylene-propylene rubber. Bentonite from different manufacturers used to increase the swelling of the samples. Filler added in an amount of 50–100 phr. The elastomeric compositions were prepared using laboratory roller at a temperature of 60 ± 5° C. Profiling was performed on a syringe-machine at a temperature of 120° C. Extrusion indicator of the mixtures were evaluated on a 10-point scale (German-Russian system. It is found that high swelling products provided using field Azerbaijan bentonite. It is noted that the dosage of bentonite than 150 w.p. deteriorates technological properties of bentonite cords. It has been shown that activation of the bentonite and sodium carbonate chloride can significantly improve product swelling, wherein the bentonite content of the composition was 150–200 w.p.

  6. Elastomeric composites with tuned electromagnetic characteristics

    International Nuclear Information System (INIS)

    Wheeland, Sara; Bayatpur, Farhad; Amirkhizi, Alireza V; Nemat-Nasser, Sia

    2013-01-01

    This paper presents a novel elastomeric composite that exhibits a deformation-induced change in chirality. Previous efforts primarily dealt with a coil array in air without chiral tuning. Here, a composite is created that consists of an array of parallel, metallic helices of the same handedness embedded in a polymer matrix. The chiral response of the composite depends on pitch, coil diameter, wire thickness and coil spacing; however, pitch has the greatest effect on electromagnetic performance. The present study explores this effect by using helical elements to construct a chiral medium that can be mechanically stretched to adjust pitch. This adjustment directly affects the overall chirality of the composite. A prototype sample of the composite, fabricated for operation between 5.5–12.5 GHz, demonstrates repeatable elastic deformation. Using a transmit/receive measurement setup, the composite scattering response is measured over the frequency interval. The results indicate substantial tuning of chirality through deformation. An increase in axial strain of up to 30% yields a ∼18% change in axial chirality. (paper)

  7. Baxter elastomeric pumps: Feasibility of weight estimates.

    Science.gov (United States)

    Chambers, Carole R; Pabia, Mica; Sawyer, Michael; Tang, Patricia A

    2017-09-01

    Purpose Elastomeric pumps are used to infuse a 46-h fluorouracil protocol and patients are asked to visually inspect the pump daily. The pump has a variability of ±10% and there are additional patient variables that can increase this. The feasibility of weighing the pump rather than a visual inspection along with the secondary objective to confirm the pump's variability in real world conditions was undertaken. Methods Empty pumps were weighed using both pharmacy and kitchen scales. Pumps upon completion of the 46-h infusion were also weighed using both pharmacy and kitchen scales. Results The kitchen scale was as accurate as the pharmacy grade scale. Disconnected pumps showed the expected variability from using these infusor pumps along with a few showing greater variability likely due to patient variables. Conclusion Weighing pumps appears to be feasible both at the pharmacy and home level. Next steps would be to weigh pumps during the infusion to validate an alternate method to simple visual inspection for patients to confirm proper infusing of the pump at their home.

  8. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  9. 40 CFR 427.40 - Applicability; description of the asbestos paper (elastomeric binder) subcategory.

    Science.gov (United States)

    2010-07-01

    ... asbestos paper (elastomeric binder) subcategory. 427.40 Section 427.40 Protection of Environment... SOURCE CATEGORY Asbestos Paper (Elastomeric Binder) Subcategory § 427.40 Applicability; description of the asbestos paper (elastomeric binder) subcategory. The provisions of this subpart are applicable to...

  10. Capacitance of circular patch resonator

    International Nuclear Information System (INIS)

    Miano, G.; Verolino, L.; Naples Univ.; Panariello, G.; Vaccaro, V.G.; Naples Univ.

    1995-11-01

    In this paper the capacitance of the circular microstrip patch resonator is computed. It is shown that the electrostatic problem can be formulated as a system of dual integral equations, and the most interesting techniques of solutions of these systems are reviewed. Some useful approximated formulas for the capacitance are derived and plots of the capacitance are finally given in a wide range of dielectric constants

  11. Enhancing retention of partial dentures using elastomeric retention rings

    Directory of Open Access Journals (Sweden)

    Kakkirala Revathi

    2015-01-01

    Full Text Available This report presents an alternative method for the retention of partial dentures that relies on the engagement of tooth undercuts by a lining material. The lab procedures are also presented. A new maxillary and mandibular acrylic partial dentures were fabricated using elastomeric retention technique for a partially dentate patient. A partially dentate man reported difficulty in retaining his upper removable partial denture (RPD. The maxillary RPD was designed utilizing elastomeric retention technique. During follow-up, it was necessary to replace the retention rings due to wear. The replacement of the retention rings, in this case, was done through a chairside reline technique. Elastomeric retention technique provides exceptionally good retention can be indicated to stabilize, cushion, splint periodontally involved teeth, no enough undercut for clasps, eliminate extractions, single or isolated teeth.

  12. Elastomeric Cellular Structure Enhanced by Compressible Liquid Filler

    Science.gov (United States)

    Sun, Yueting; Xu, Xiaoqing; Xu, Chengliang; Qiao, Yu; Li, Yibing

    2016-05-01

    Elastomeric cellular structures provide a promising solution for energy absorption. Their flexible and resilient nature is particularly relevant to protection of human bodies. Herein we develop an elastomeric cellular structure filled with nanoporous material functionalized (NMF) liquid. Due to the nanoscale infiltration in NMF liquid and its interaction with cell walls, the cellular structure has a much enhanced mechanical performance, in terms of loading capacity and energy absorption density. Moreover, it is validated that the structure is highly compressible and self-restoring. Its hyper-viscoelastic characteristics are elucidated.

  13. Characteristic evolutions in numerical relativity using six angular patches

    International Nuclear Information System (INIS)

    Reisswig, Christian; Bishop, Nigel T; Lai, Chi Wai; Thornburg, Jonathan; Szilagyi, Bela

    2007-01-01

    The characteristic approach to numerical relativity is a useful tool in evolving gravitational systems. In the past this has been implemented using two patches of stereographic angular coordinates. In other applications, a six-patch angular coordinate system has proved effective. Here we investigate the use of a six-patch system in characteristic numerical relativity, by comparing an existing two-patch implementation (using second-order finite differencing throughout) with a new six-patch implementation (using either second- or fourth-order finite differencing for the angular derivatives). We compare these different codes by monitoring the Einstein constraint equations, numerically evaluated independently from the evolution. We find that, compared to the (second-order) two-patch code at equivalent resolutions, the errors of the second-order six-patch code are smaller by a factor of about 2, and the errors of the fourth-order six-patch code are smaller by a factor of nearly 50

  14. Characteristic evolutions in numerical relativity using six angular patches

    Energy Technology Data Exchange (ETDEWEB)

    Reisswig, Christian [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany); Bishop, Nigel T [Department of Mathematical Sciences, University of South Africa, PO Box 392, Unisa 0003, South Africa (South Africa); Lai, Chi Wai [Department of Mathematical Sciences, University of South Africa, PO Box 392, Unisa 0003, South Africa (South Africa); Thornburg, Jonathan [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany); Szilagyi, Bela [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany)

    2007-06-21

    The characteristic approach to numerical relativity is a useful tool in evolving gravitational systems. In the past this has been implemented using two patches of stereographic angular coordinates. In other applications, a six-patch angular coordinate system has proved effective. Here we investigate the use of a six-patch system in characteristic numerical relativity, by comparing an existing two-patch implementation (using second-order finite differencing throughout) with a new six-patch implementation (using either second- or fourth-order finite differencing for the angular derivatives). We compare these different codes by monitoring the Einstein constraint equations, numerically evaluated independently from the evolution. We find that, compared to the (second-order) two-patch code at equivalent resolutions, the errors of the second-order six-patch code are smaller by a factor of about 2, and the errors of the fourth-order six-patch code are smaller by a factor of nearly 50.

  15. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    Science.gov (United States)

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Granisetron Transdermal Patch

    Science.gov (United States)

    Granisetron transdermal patches are used to prevent nausea and vomiting caused by chemotherapy. Granisetron is in a class of medications called 5HT3 ... Granisetron transdermal comes as a patch to apply to the skin. It is usually applied 24 to ...

  17. Elastomeric neutron shielding material and process of production

    International Nuclear Information System (INIS)

    John, G.; Knorr, W.

    1987-01-01

    Elastomeric neutron shielding material made of plastic with high hydrogen content, characterized in that the shielding material is a polymeric reaction product of a reaction between (a) polyol on the base of polybutadiene which compares with polyethylene with regard to hydrogen content, and (b) aliphatic diisocyanate, and in that the hydrogen content is higher than 8 weight per cent. (orig.) [de

  18. Estradiol Transdermal Patch

    Science.gov (United States)

    ... menopause (change of life; the end of monthly menstrual periods). Transdermal estradiol is also used to prevent ... patch. Ask your pharmacist or doctor for a copy of the manufacturer's information for the patient.

  19. Fentanyl Transdermal Patch

    Science.gov (United States)

    Fentanyl patches are used to relieve severe pain in people who are expected to need pain medication ... and who cannot be treated with other medications. Fentanyl is in a class of medications called opiate ( ...

  20. Selegiline Transdermal Patch

    Science.gov (United States)

    ... patch from direct heat such as heating pads, electric blankets, heat lamps, saunas, hot tubs, and heated ... may make you drowsy. Do not drive a car or operate machinery until you know how this ...

  1. Testosterone Transdermal Patch

    Science.gov (United States)

    ... one else can use it accidentally or on purpose. Keep track of how many patches are left ... to your pharmacist or contact your local garbage/recycling department to learn about take-back programs in ...

  2. Rotigotine Transdermal Patch

    Science.gov (United States)

    ... physical activity. If the edges of the patch lift, use a bandage tape to re-secure it ... burns on your skin if you are having magnetic resonance imaging (MRI; a radiology technique designed to ...

  3. Methylphenidate Transdermal Patch

    Science.gov (United States)

    ... for ADHD, which may include counseling and special education. Make sure to follow all of your doctor's ... that was covered by the patch seizures motion tics or verbal tics believing things that are not ...

  4. Windows Security patch required

    CERN Multimedia

    3004-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  5. Biocide patch tests

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Veien, Niels

    1985-01-01

    Routine patch testing with a series of 6 industrial biocides containing methylene-bis-thiocyanate (Cytox 3522), benzisothiazolin-3-one (BIT), chlorocresol (Preventol CMK), 2-n-octyl-4-isothiazolin-3-one (Kathon 893), polyhydroxymethylene monobenzylether (Preventol D2) or 1,3,5-tris (hydroxy......-ethyl) hexahydrotriazine (Grotan BK) was carried out in 6 Danish out-patient clinics to evaluate guinea pig allergy test results with the same compounds. A total of 1652 consecutive patients with dermatitis were tested. The usefulness of this patch test battery was limited. There were a few positive reactions to Cytox...... of male patients and atopics, but significant differences in the frequencies of occupational cases, hand eczemas, and leg ulcers/stasis dermatitis, indicating possible variations in referral patterns, use of patch tests, and/or environmental factors....

  6. Generic patch inference

    DEFF Research Database (Denmark)

    Andersen, Jesper; Lawall, Julia

    2010-01-01

    A key issue in maintaining Linux device drivers is the need to keep them up to date with respect to evolutions in Linux internal libraries. Currently, there is little tool support for performing and documenting such changes. In this paper we present a tool, spdiff, that identifies common changes...... developers can use it to extract an abstract representation of the set of changes that others have made. Our experiments on recent changes in Linux show that the inferred generic patches are more concise than the corresponding patches found in commits to the Linux source tree while being safe with respect...

  7. [Patch testing: historical aspects].

    Science.gov (United States)

    Lachapelle, J-M

    2009-01-01

    This article reviews the key points in the history of patch testing, which spans more than a century, starting with the first description of the method by J. Jadassohn in 1895. Special attention is paid to the contribution of French schools in this field, which led to the foundation of the Groupe d'études et de recherches en dermato-allergologie (GERDA).

  8. Performance testing of elastomeric seal materials under low and high temperature conditions: Final report

    Energy Technology Data Exchange (ETDEWEB)

    BRONOWSKI,DAVID R.

    2000-06-01

    The US Department of Energy Offices of Defense Programs and Civilian Radioactive Waste Management jointly sponsored a program to evaluate elastomeric O-ring seal materials for radioactive material shipping containers. The report presents the results of low- and high-temperature tests conducted on 27 common elastomeric compounds.

  9. Dermoscopy of shagreen patch: A first report

    Directory of Open Access Journals (Sweden)

    Shivanand Gundalli

    2015-07-01

    Full Text Available The name is derived from French phrase peau chagrinee which is usually found on lower back, buttock and thigh. The major manifestations of Tuberous sclerosis include skin lesions in more than 95%, mental retardation in approximately 50%, autism, seizures in approximately 85%. The incidence at birth is estimated to be 1 in 5800. We report case of shagreen patch in a 27 year female which is present since birth. However there is no history of seizures or consanginous marriage in our case. Associated features are naevus comedonicus and naevus collagenosis, facial angiofibroma. Shagreen patch are present in mandibular area of face. Although, diagnosis is easy, it can be mistaken for inflammatory verrucous epidermal nevus, plaques of other inflammatory skin conditions. Diagnosis is usually on clinical background. Sometimes biopsy is necessary to confirm the diagnosis. Dermoscopy, a non-invasive, in vivo technique for the microscopic examination of pigmented skin lesions, has the potential to improve the diagnostic accuracy. Dermoscopy of Shagreen patch showed reddish-brown strands with white dots giving a cobblestone appearance It can be utilized as a diagnostic aide in the diagnosis of Shagreen patch. Authors evaluated the dermoscopic patterns of Shagreen patch and hence, it is useful in diagnosis.

  10. Interaction of Reinforced Elastomeric Bearings in Bridge Construction

    Directory of Open Access Journals (Sweden)

    Nittmannová Ľubica

    2016-03-01

    Full Text Available The aim of this paper is to demonstrate the behavior of reinforced elastomeric bearings under various loads. They are made of special types of bearings. The experimental verification of these special bearings has been tested on various types of loading. The results of the experimental measurements are compared with the results of the numerical modeling and calculations according to the standard assumptions in STN EN 1337-3. In the conclusion, the results are summarized for the selected types of bearings.

  11. The hedgehog receptor patched is involved in cholesterol transport.

    Directory of Open Access Journals (Sweden)

    Michel Bidet

    Full Text Available Sonic hedgehog (Shh signaling plays a crucial role in growth and patterning during embryonic development, and also in stem cell maintenance and tissue regeneration in adults. Aberrant Shh pathway activation is involved in the development of many tumors, and one of the most affected Shh signaling steps found in these tumors is the regulation of the signaling receptor Smoothened by the Shh receptor Patched. In the present work, we investigated Patched activity and the mechanism by which Patched inhibits Smoothened.Using the well-known Shh-responding cell line of mouse fibroblasts NIH 3T3, we first observed that enhancement of the intracellular cholesterol concentration induces Smoothened enrichment in the plasma membrane, which is a crucial step for the signaling activation. We found that binding of Shh protein to its receptor Patched, which involves Patched internalization, increases the intracellular concentration of cholesterol and decreases the efflux of a fluorescent cholesterol derivative (BODIPY-cholesterol from these cells. Treatment of fibroblasts with cyclopamine, an antagonist of Shh signaling, inhibits Patched expression and reduces BODIPY-cholesterol efflux, while treatment with the Shh pathway agonist SAG enhances Patched protein expression and BODIPY-cholesterol efflux. We also show that over-expression of human Patched in the yeast S. cerevisiae results in a significant boost of BODIPY-cholesterol efflux. Furthermore, we demonstrate that purified Patched binds to cholesterol, and that the interaction of Shh with Patched inhibits the binding of Patched to cholesterol.Our results suggest that Patched may contribute to cholesterol efflux from cells, and to modulation of the intracellular cholesterol concentration. This activity is likely responsible for the inhibition of the enrichment of Smoothened in the plasma membrane, which is an important step in Shh pathway activation.

  12. Patch Test Negative Generalized Dermatitis.

    Science.gov (United States)

    Spiker, Alison; Mowad, Christen

    2016-01-01

    Allergic contact dermatitis is a common condition in dermatology. Patch testing is the criterion standard for diagnosis. However, dermatitis is not always caused by an allergen, and patch testing does not identify a culprit in every patient. Generalized dermatitis, defined as eczematous dermatitis affecting greater than 3 body sites, is often encountered in dermatology practice, especially patch test referral centers. Management for patients with generalized dermatitis who are patch test negative is challenging. The purpose of this article is to outline an approach to this challenging scenario and summarize the paucity of existing literature on patch test negative generalized dermatitis.

  13. Elastically stretchable thin film conductors on an elastomeric substrate

    Science.gov (United States)

    Jones Harris, Joyelle Elizabeth

    Imagine a large, flat screen television that can be rolled into a small cylinder after purchase in the store and then unrolled and mounted onto the wall of a home. The electronic devices within the television must be able to withstand large deformation and tensile strain. Consider a robot that is covered with an electronic skin that simulates human skin. The skin would enable the machine to lift an elderly person with care and sensitivity. The skin will endure repeated deformation with the highest tensile strains being experienced at the robot's joints. These applications and many others will benefit from stretchable electronic circuitry. While several different methods have been employed to create stretchable electronics, all methods use a common tool -- stretchable conductors. Therefore, the goal of this thesis work was to fabricate elastically stretchable conductors that can be used in stretchable electronics. We deposited Au thin films on an elastomeric substrate, and the resulting conductors remained electrically continuous when stretched by 30% and more. We developed photolithographic processes that can be used to pattern elastically stretchable conductors with a 10 mum resolution. We fabricated bi-level stretchable conductors that are separated by an elastomeric insulator and are electrically connected through via holes in the insulator. We applied our bi-level conductors to create a stretchable resistor-inductor-capacitor (RLC) circuit with a tunable resonant frequency. We also used stretchable conductors to measure action potentials in biological samples. This thesis describes the fabrication and application of our elastically stretchable conductors.

  14. Adjustment of Part Properties for an Elastomeric Laser Sintering Material

    Science.gov (United States)

    Wegner, A.; Ünlü, T.

    2018-03-01

    Laser sintering of polymers is gaining more and more importance within the field of small series productions. Polyamide 12 is predominantly used, although a variety of other materials are also available for the laser sintering process. For example, elastomeric, rubberlike materials offer very different part property profiles. Those make the production of flexible parts like, e.g., sealings, flexible tubes or shoe soles possible because they offer high part ductility and low hardness. At the chair for manufacturing technology, a new elastomeric laser sintering material has been developed and then commercialized by a spin-off from university. The aim of the presented study was the analysis of the new material's properties. Proof was found that Shore hardness can be modified by varying the parameter settings. Therefore, the correlation between process parameters, energy input, Shore hardness and other part properties like mechanical properties were analyzed. Based on these results, suitable parameter settings were established which lead to the possibility of producing parts with different Shore hardnesses.

  15. Mechanically programmed shape change in laminated elastomeric composites.

    Science.gov (United States)

    Robertson, Jaimee M; Torbati, Amir H; Rodriguez, Erika D; Mao, Yiqi; Baker, Richard M; Qi, H Jerry; Mather, Patrick T

    2015-07-28

    Soft, anisotropic materials, such as myocardium in the heart and the extracellular matrix surrounding cells, are commonly found in nature. This anisotropy leads to specialized responses and is imperative to material functionality, yet few soft materials exhibiting similar anisotropy have been developed. Our group introduced an anisotropic shape memory elastomeric composite (A-SMEC) composed of non-woven, aligned polymer fibers embedded in an elastomeric matrix. The composite exhibited shape memory (SM) behavior with significant anisotropy in room-temperature shape fixing. Here, we exploit this anisotropy by bonding together laminates with oblique anisotropy such that tensile deformation at room temperature - mechanical programming - results in coiling. This response is a breakthrough in mechanical programming, since non-affine shape change is achieved by simply stretching the layered A-SMECs at room temperature. We will show that pitch and curvature of curled geometries depend on fiber orientations and the degree of strain programmed into the material. To validate experimental results, a model was developed that captures the viscoplastic response of A-SMECs. Theoretical results correlated well with experimental data, supporting our conclusions and ensuring attainability of predictable curling geometries. We envision these smart, soft, shape changing materials will have aerospace and medical applications.

  16. A guide to the suitability of elastomeric seal materials for use in radioactive material transport packages

    International Nuclear Information System (INIS)

    Vince, D.J.

    2004-01-01

    Elastomeric seals are a frequently favoured method of sealing Radioactive Material Transport (RMT) packages. The sealing technology has been proven for many years in a wide range of industrial applications. The requirements of the RMT package applications, however, are significantly different from those commonly found in other industries. This guide outlines the Regulatory performance requirements placed on an RMT package sealing system by TS-R-1, and then summarises the material, environment and geometry characteristics of elastomeric seals relevant to RMT applications. Tables in the guide list typical material properties for a range of elastomeric materials commonly used in RMT packages

  17. Elastomeric polymer resonant waveguide grating based pressure sensor

    International Nuclear Information System (INIS)

    Song, Fuchuan; Xie, Antonio Jou; Seo, Sang-Woo

    2014-01-01

    In this paper, we demonstrate an elastomeric polymer resonant waveguide grating structure to be used as a pressure sensor. The applied pressure is measured by optical resonance spectrum peak shift. The sensitivity—as high as 86.74 pm psi −1 or 12.58 pm kPa −1 —has been experimentally obtained from a fabricated sensor. Potentially, the sensitivity of the demonstrated sensor can be tuned to different pressure ranges by the choices of elastic properties and layer thicknesses of the waveguide and cladding layers. The simulation results agree well with experimental results and indicate that the dominant effect on the sensor is the change of grating period when external pressure is applied. Based on the two-dimensional planar structure, the demonstrated sensor can be used to measure applied surface pressure optically, which has potential applications for optical ultrasound imaging and pressure wave detection/mapping

  18. Seismic isolation of nuclear power plants using elastomeric bearings

    Science.gov (United States)

    Kumar, Manish

    Seismic isolation using low damping rubber (LDR) and lead-rubber (LR) bearings is a viable strategy for mitigating the effects of extreme earthquake shaking on safety-related nuclear structures. Although seismic isolation has been deployed in nuclear structures in France and South Africa, it has not seen widespread use because of limited new build nuclear construction in the past 30 years and a lack of guidelines, codes and standards for the analysis, design and construction of isolation systems specific to nuclear structures. The nuclear accident at Fukushima Daiichi in March 2011 has led the nuclear community to consider seismic isolation for new large light water and small modular reactors to withstand the effects of extreme earthquakes. The mechanical properties of LDR and LR bearings are not expected to change substantially in design basis shaking. However, under shaking more intense than design basis, the properties of the lead cores in lead-rubber bearings may degrade due to heating associated with energy dissipation, some bearings in an isolation system may experience net tension, and the compression and tension stiffness may be affected by the horizontal displacement of the isolation system. The effects of intra-earthquake changes in mechanical properties on the response of base-isolated nuclear power plants (NPPs) were investigated using an advanced numerical model of a lead-rubber bearing that has been verified and validated, and implemented in OpenSees and ABAQUS. A series of experiments were conducted at University at Buffalo to characterize the behavior of elastomeric bearings in tension. The test data was used to validate a phenomenological model of an elastomeric bearing in tension. The value of three times the shear modulus of rubber in elastomeric bearing was found to be a reasonable estimate of the cavitation stress of a bearing. The sequence of loading did not change the behavior of an elastomeric bearing under cyclic tension, and there was no

  19. Method optimization of ocular patches

    Directory of Open Access Journals (Sweden)

    Kamalesh Upreti

    2012-01-01

    Full Text Available The intraocular patches were prepared using gelatin as the polymer. Ocular patch were prepared by solvent casting method. The patches were prepared for six formulations GP1, GP2, GP3, GP4, GP5 and GP6. Petri dishes were used for formulation of ocular patch. Gelatin was used as a polymer of choice. Glutaraldehyde used as cross linking agent and (DMSO dimethylsulfoxide used as solubility enhancer. The elasticity depends upon the concentration of gelatin. 400 mg amount of polymer i.e gelatin gave the required elasticity for the formulation.

  20. Non-standard patch test

    Directory of Open Access Journals (Sweden)

    Astri Adelia

    2018-06-01

    Full Text Available In managing contact dermatitis, identification of the causative agent is essential to prevent recurrent complaints. Patch test is the gold standard to identify the causative agent. Nowadays, there are many patch test standard materials available in the market, but do not include all the materials that potentially cause contact dermatitis. Patch test using patient’s own products or later we refer to as non-standard materials, is very helpful in identifying the causative agents of contact dermatitis. Guidance is needed in producing non-standard patch test materials in order to avoid test results discrepancy.

  1. Linear dimensional stability of elastomeric impression materials over time.

    Science.gov (United States)

    Garrofé, Analía B; Ferrari, Beatriz A; Picca, Mariana; Kaplan, Andrea E

    2011-01-01

    The purpose of this study was to evaluate the linear dimensional stability of different elastomeric impression materials over time. A metal mold was designed with its custom trays, which were made of thermoplastic sheets (Sabilex sheets 0.125 mm thick). Three impressions were taken of it with each of the following: the polyvinylsiloxane Examix-GC-(AdEx), Aquasil-Dentsply-(AdAq) and Panasil-Kettenbach-(AdPa), and the polydimethylsiloxane Densell-Dental Medrano-(CoDe), Speedex-Coltene-(CoSp) and Lastic-Kettenbach-(CoLa). All impressions were taken with putty and light-body materials using a one-step technique. Standardized digital photographs were taken at different time intervals (0, 15, 30, 60, 120 minutes; 24 hours; 7 and 14 days), using an "ad-hoc" device, and analyzed using software (Image Tool) by measuring the distance between lines previously made at the top of the mold. The results were analyzed by ANOVA for repeated measures. The initial and final values for mean and SD were: AdEx: 1.32 (0.01) and 1.31 (0.00); AdAq: 1.32 (0.00) and 1.32 (0.00), AdPa: 1.327 (0.006) and 1.31 (0.00); CoDe: 1.32 (0.00) and 1.32 (0.01); CoSp: 1.327 (0.006) and 1.31 (0.00), CoLa: 1.327 (0.006) and 1.303 (0.006). Statistical evaluation showed that both material and time have significant effects. Under the conditions in this study we conclude that time would significantly affect the lineal dimensional stability of elastomeric impression materials.

  2. Engineered elastomeric proteins with dual elasticity can be controlled by a molecular regulator.

    Science.gov (United States)

    Cao, Yi; Li, Hongbin

    2008-08-01

    Elastomeric proteins are molecular springs that confer excellent mechanical properties to many biological tissues and biomaterials. Depending on the role performed by the tissue or biomaterial, elastomeric proteins can behave as molecular springs or shock absorbers. Here we combine single-molecule atomic force microscopy and protein engineering techniques to create elastomeric proteins that can switch between two distinct types of mechanical behaviour in response to the binding of a molecular regulator. The proteins are mechanically labile by design and behave as entropic springs with an elasticity that is governed by their configurational entropy. However, when a molecular regulator binds to the protein, it switches into a mechanically stable state and can act as a shock absorber. These engineered proteins effectively mimic and combine the two extreme forms of elastic behaviour found in natural elastomeric proteins, and thus represent a new type of smart nanomaterial that will find potential applications in nanomechanics and material sciences.

  3. Flexible Connection Elastomeric Rubber as a Pounding Resisting Element between Two Adjacent Buildings

    Directory of Open Access Journals (Sweden)

    Yuskar Lase

    2013-03-01

    Full Text Available To solve pounding problem of two adjacent buildings, structural designer usually employs a dilatation between the structures or make the two structures as a monolith structure. Other alternative is by using an elastomeric rubber as a pounding resisting element between the two structures. Effectiveness in applying elastomeric rubber component as flexible connection of two adjacent structures is the main focus of this paper. Various simulations such as structure models, earthquake excitations and openings in gap element are studied. Observation of maximum structural responses will be performed for structure model with elastomeric rubber in comparison with (1 monolith structure model and (2 structure model with rigid element (steel element. Simulation results show that application of elastomeric rubber component to prevent structures from pounding problem provides advantages especially in reducing internal forces in the shorter building. However, it slightly increases displacement of both structures.

  4. Correlation between in vitro Elastomeric Force Degradation and Glass Transition Temperature determined by Dynamic Mechanical Analysis

    Directory of Open Access Journals (Sweden)

    Manu Krishnan

    2012-01-01

    Conclusion: Tg can be considered as a dependable parameter in envisaging the force properties of an elastomeric chain. Clinically, it suggested that a polymer with higher Tg can give higher or optimum levels of force for tooth movement.

  5. Evaluation of the cytotoxicity of elastomeric ligatures after sterilisation with 0.25% peracetic acid.

    Science.gov (United States)

    Pithon, Matheus Melo; dos Santos, Rogerio Lacerda; Judice, Renata Lima Pasini; de Assuncao, Paulo Sergio; Restle, Luciana

    2013-11-01

    Sterilisation using peracetic acid (PAA) has been advocated for orthodontic elastic bands. However, cane-loaded elastomeric ligatures can also become contaminated during processing, packaging, and manipulation before placement in the oral cavity and are therefore susceptible, and possible causes, of cross-contamination. To test the hypothesis that 0.25% peracetic acid (PAA), following the sterilisation of elastomers, influences the cytotoxicity of elastomeric ligatures on L929 cell lines. Four hundred and eighty silver elastomeric ligatures were divided into 4 groups of 120 ligatures to produce, Group TP (latex natural, bulk pack, TP Orthodontics), Group M1 (Polyurethane, bulk pack, Morelli), Group M2 (Polyurethane, cane-loaded, Morelli) and Group U (Polyurethane, cane-loaded, Uniden). Of the 120 ligatures in each group, 100 were sterilised in 0.25% PAA at time intervals (N = 20) of 1 hour, 2 hours, 3 hours, 4 hours and 5 hours. The 20 remaining elastomeric ligatures in each group were not sterilised and served as controls. Cytotoxicity was assessed using L929 cell lines and a dye-uptake method. Analysis of variance (ANOVA), followed by the Tukey post hoc test (p < 0.05) determined statistical relevance. There was a significant difference between TP, Morelli and Uniden elastomerics (p < 0.05), but no difference between the two types of Morelli elastomerics at the 1 hour time interval. In addition, there was a significant difference between Group CC and the other groups assessed, except between Groups CC and TP at the 1 hour time interval. The non-sterilised elastomeric ligatures showed similar cell viability to that observed after 1 hour of standard sterilisation. PAA did not significantly influence the cytotoxicity of elastomeric ligatures after a sterilisation time of 1 hour and is therefore recommended for clinical use.

  6. Analysis of the Influence of Food Colorings in Esthetic Orthodontic Elastomeric Ligatures.

    Science.gov (United States)

    Dias da Silva, Vanessa; de Lima, Eduardo Martinelli S; Dias, Caroline; Osório, Leandro Berni

    2016-01-01

    The purpose of this study was to evaluate in vitro the color changes of esthetic orthodontic elastomeric ligatures of different shades when exposed to four food colorings commonly found in the diet of patients. The sample consisted of esthetic orthodontic elastomeric ligatures in the colors pearl, pearl blue, pearl white and colorless, which were immersed for 72 hours in five different solutions: distilled water (control group), coffee, tea, Coca-Cola ® and wine. The color changes of the esthetic orthodontic elastomeric ligatures were measured with the aid of a spectrophotometer, at T1 - as provided by the manufacturer; and T2 - after colorings process. The results indicated that the esthetic orthodontic elastomeric ligatures of all initial hues are susceptible to pigmentation. Among the evaluated colors, all changed the finished look and the color of the samples tested. In ascending order, the color of the samples was as follows: distilled water, Coca-Cola ® , black tea, wine and coffee. The substances that have a greater potential for pigmentation in esthetic orthodontic elastomeric ligatures were black tea, wine and coffee, respectively. All shades of esthetic orthodontic elastomeric ligatures are susceptible to color change.

  7. Edge of polar cap patches

    Science.gov (United States)

    Hosokawa, K.; Taguchi, S.; Ogawa, Y.

    2016-04-01

    On the night of 4 December 2013, a sequence of polar cap patches was captured by an all-sky airglow imager (ASI) in Longyearbyen, Norway (78.1°N, 15.5°E). The 630.0 nm airglow images from the ASI of 4 second exposure time, oversampled the emission of natural lifetime (with quenching) of at least ˜30 sec, introduce no observational blurring effects. By using such high-quality ASI images, we succeeded in visualizing an asymmetry in the gradients between the leading/trailing edges of the patches in a 2-D fashion. The gradient in the leading edge was found to be 2-3 times steeper than that in the trailing edge. We also identified fingerlike structures, appearing only along the trailing edge of the patches, whose horizontal scale size ranged from 55 to 210 km. These fingers are considered to be manifestations of plasma structuring through the gradient-drift instability (GDI), which is known to occur only along the trailing edge of patches. That is, the current 2-D observations visualized, for the first time, how GDI stirs the patch plasma and such a mixing process makes the trailing edge more gradual. This result strongly implies a close connection between the GDI-driven plasma stirring and the asymmetry in the large-scale shape of patches and then suggests that the fingerlike structures can be used as markers to estimate the fine-scale structure in the plasma flow within patches.

  8. *New* CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  9. *New*: CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  10. Thermal stability of the elastomeric anti-trauma pad

    Directory of Open Access Journals (Sweden)

    Olszewska Karolina

    2017-06-01

    Full Text Available The elastomeric anti-trauma pad (EA-TP based on shear thickening fluid (STF has been developed. Dynamic oscillatory shear experiment was conducted at constant strain amplitude of 5%. STF composed of 25% of volume fraction of 7 nm Fumed Silica, dispersed in polypropylene glycol with molar mass 400 gmol−1 shows elastic properties in entire investigated range of the frequency. Ballistic tests of EA-TP with 7.62 mm × 39 mm PS bullets were performed according to the PN-V-87000:2011 standard. The studies revealed about 60% reduction of the average backface signature depth (BSD for the EA-TP, when compared to the nowadays commonly used soft insert. The ATR-FTIR analysis confirmed slight impact of the elevated temperature and air (oxygen on the chemical degradation of the EA-TP surface. The UV-VIS spectroscopy has allowed to notice colour deviation of the aged samples towards green and yellow, as well as lack of dye resistance to accelerated aging process. Thermographic analysis has shown no visible changes of the EA-TP surface and sub-surface during accelerated aging process. The aforementioned small changes on the surface of EA-TP did not affect the ballistic properties of composite armour. EA-TP insert maintains ballistic properties after accelerated aging process which was simulating the period of 6 years according to ASTM F1980 – 07:2002 standard.

  11. Diffusion of nanoparticles in solution through elastomeric membrane

    Science.gov (United States)

    Zemzem, Mohamed; Vinches, Ludwig; Hallé, Stéphane

    2017-04-01

    Diffusion phenomena encountered in mass transfer of liquids play an important role in many technological processes of polymer manufacturing and use. In addition and alongside the notable growth of nanoparticles use, particularly when in suspension in liquid solutions, it has become important to pay some attention to their interactions with polymeric structures. The aim of this work is to evaluate some diffusion parameters of gold nanoparticle solutions as well as of their liquid carrier (water) through elastomeric membranes. Gravimetric method was chosen as the main technique to quantify swelling phenomena and to assess kinetic properties. The dynamic liquid uptake measurements were conducted on gold nanoparticles (5 nm and 50 nm in diameter) in aqueous solutions when brought into contact with two types of nitrile material samples. Results showed that diffusion mechanism of the liquids lies between Fickian and sub-Fickian modes. Slight deviations were noticed with the gold nanoparticle solutions. A growth in liquid interaction with the rubbery structure in presence of the nanoparticles was also observed from comparison of K factor (characteristic of the elastomer-liquid interaction). Difference between the characteristics of the two membranes was also reported using this parameter. Besides, diffusion coefficients testified the impact of the membrane thickness on the penetration process, while no significant effect of the nature of the nanoparticle solution can be seen on this coefficient.

  12. Diffusion of nanoparticles in solution through elastomeric membrane

    International Nuclear Information System (INIS)

    Zemzem, Mohamed; Vinches, Ludwig; Hallé, Stéphane

    2017-01-01

    Diffusion phenomena encountered in mass transfer of liquids play an important role in many technological processes of polymer manufacturing and use. In addition and alongside the notable growth of nanoparticles use, particularly when in suspension in liquid solutions, it has become important to pay some attention to their interactions with polymeric structures. The aim of this work is to evaluate some diffusion parameters of gold nanoparticle solutions as well as of their liquid carrier (water) through elastomeric membranes. Gravimetric method was chosen as the main technique to quantify swelling phenomena and to assess kinetic properties. The dynamic liquid uptake measurements were conducted on gold nanoparticles (5 nm and 50 nm in diameter) in aqueous solutions when brought into contact with two types of nitrile material samples. Results showed that diffusion mechanism of the liquids lies between Fickian and sub-Fickian modes. Slight deviations were noticed with the gold nanoparticle solutions. A growth in liquid interaction with the rubbery structure in presence of the nanoparticles was also observed from comparison of K factor (characteristic of the elastomer-liquid interaction). Difference between the characteristics of the two membranes was also reported using this parameter. Besides, diffusion coefficients testified the impact of the membrane thickness on the penetration process, while no significant effect of the nature of the nanoparticle solution can be seen on this coefficient. (paper)

  13. Strain-dependent dynamic compressive properties of magnetorheological elastomeric foams

    Science.gov (United States)

    Wereley, Norman M.; Perez, Colette; Choi, Young T.

    2018-05-01

    This paper addresses the strain-dependent dynamic compressive properties (i.e., so-called Payne effect) of magnetorheological elastomeric foams (MREFs). Isotropic MREF samples (i.e., no oriented particle chain structures), fabricated in flat square shapes (nominal size of 26.5 mm x 26.5 mm x 9.5 mm) were synthesized by randomly dispersing micron-sized iron oxide particles (Fe3O4) into a liquid silicone foam in the absence of magnetic field. Five different Fe3O4 particle concentrations of 0, 2.5, 5.0, 7.5, and 10 percent by volume fraction (hereinafter denoted as vol%) were used to investigate the effect of particle concentration on the dynamic compressive properties of the MREFs. The MREFs were sandwiched between two multi-pole flexible plate magnets in order to activate the magnetorheological (MR) strengthening effect. Under two different pre-compression conditions (i.e., 35% and 50%), the dynamic compressive stresses of the MREFs with respect to dynamic strain amplitudes (i.e., 1%-10%) were measured by using a servo-hydraulic testing machine. The complex modulus (i.e., storage modulus and loss modulus) and loss factors of the MREFs with respect to dynamic strain amplitudes were presented as performance indices to evaluate their strain-dependent dynamic compressive behavior.

  14. Strain-dependent dynamic compressive properties of magnetorheological elastomeric foams

    Directory of Open Access Journals (Sweden)

    Norman M. Wereley

    2018-05-01

    Full Text Available This paper addresses the strain-dependent dynamic compressive properties (i.e., so-called Payne effect of magnetorheological elastomeric foams (MREFs. Isotropic MREF samples (i.e., no oriented particle chain structures, fabricated in flat square shapes (nominal size of 26.5 mm x 26.5 mm x 9.5 mm were synthesized by randomly dispersing micron-sized iron oxide particles (Fe3O4 into a liquid silicone foam in the absence of magnetic field. Five different Fe3O4 particle concentrations of 0, 2.5, 5.0, 7.5, and 10 percent by volume fraction (hereinafter denoted as vol% were used to investigate the effect of particle concentration on the dynamic compressive properties of the MREFs. The MREFs were sandwiched between two multi-pole flexible plate magnets in order to activate the magnetorheological (MR strengthening effect. Under two different pre-compression conditions (i.e., 35% and 50%, the dynamic compressive stresses of the MREFs with respect to dynamic strain amplitudes (i.e., 1%-10% were measured by using a servo-hydraulic testing machine. The complex modulus (i.e., storage modulus and loss modulus and loss factors of the MREFs with respect to dynamic strain amplitudes were presented as performance indices to evaluate their strain-dependent dynamic compressive behavior.

  15. Unification of reactor elastomeric sealing based on material

    International Nuclear Information System (INIS)

    Sinha, N.K.; Raj, Baldev

    2012-01-01

    The unification of elastomeric sealing applications of Indian nuclear reactors based on a few qualified fluoroelastomer/perfluoroelastomer compounds and standardized approaches for finite element analysis (FEA) based design, manufacturing process and antifriction coatings is discussed. It is shown that the advance polymer architecture based Viton ® formulation developed for inflatable seals of 500 MWe Prototype Fast Breeder Reactor (PFBR) and its four basic variations can encompass other sealing applications of PFBR with minimum additional efforts on development and validation. Changing the blend ratio of Viton ® GBL 200S and 600S in inflatable seal formulation could extend its use to Pressurized Heavy Water Reactors (PHWRs). The higher operating temperature of Advanced Heavy Water Reactor (AHWR) seals expands the choice to perfluoroelastomers. FEA based on plane-strain/axisymmetric modeling (with Mooney–Rivlin as the basic constitutive model), seal manufacture by cold feed extrusion and injection molding as well as plasma Teflon-like coating belonging to two variations obtained from the development of inflatable seals provide the necessary standardization for unification. The gains in simplification of design, development and operation of seals along with the enhancements of safety and reliability are expected to be substantial.

  16. DEA deformed stretchable patch antenna

    International Nuclear Information System (INIS)

    Jiang, X-J; Jalali Mazlouman, S; Menon, C; Mahanfar, A; Vaughan, R G

    2012-01-01

    A stretchable patch antenna (SPA) whose frequency is tuned by a planar dielectric elastomer actuator (DEA) is presented in this paper. This mechanically reconfigurable antenna system has a configuration resembling a pre-stretched silicone belt. Part of the belt is embedded with a layer of conductive liquid metal to form the patch antenna. Part of the belt is sandwiched between conductive electrodes to form the DEA. Electrical activation of the DEA results in a contraction of the patch antenna, and as a result, in a variation of its resonance frequency. Design and fabrication steps of this system are presented. Measurement results for deformation, resonance frequency variation and efficiency of the patch antenna are also presented. (paper)

  17. Flu Vaccine Skin Patch Tested

    Science.gov (United States)

    ... Subscribe September 2017 Print this issue Health Capsule Flu Vaccine Skin Patch Tested En español Send us ... Each year, millions of people nationwide catch the flu. The best way to protect yourself is to ...

  18. Static frictional resistance with the slide low-friction elastomeric ligature system.

    Science.gov (United States)

    Jones, Steven P; Ben Bihi, Saida

    2009-11-01

    This ex-vivo study compared the static frictional resistance of a low-friction ligation system against a conventional elastomeric module, and studied the effect of storage in a simulated oral environment on the static frictional resistance of both ligation systems. Eighty stainless steel brackets were tested by sliding along straight lengths of 0.018 inch round and 0.019 x 0.025 inch rectangular stainless steel wires ligated with either conventional elastomerics or the Slide system (Leone, Florence, Italy). During the tests the brackets and wires were lubricated with artificial saliva. A specially constructed jig assembly was used to hold the bracket and archwire securely. The jig was clamped in an Instron universal load testing machine. Crosshead speed was controlled via a microcomputer connected to the Instron machine. The static frictional forces at 0 degree bracket/wire angulation were measured for both systems, fresh from the pack and after storage in artificial saliva at 37 degrees C for 24 hours. The results of this investigation demonstrated that the Slide ligatures produced significantly lower static frictional resistance than conventional elastomeric modules in the fresh condition and after 24 hours of storage in a simulated oral environment (p static frictional resistance of conventional elastomeric modules and the Slide system (p = 0.525). The claim by the manufacturer that the Slide system produces lower frictional resistance than conventional elastomeric modules is upheld.

  19. Tribological properties and morphology of bimodal elastomeric nitrile butadiene rubber networks

    International Nuclear Information System (INIS)

    Guo, Yin; Wang, Jiaxu; Li, Kang; Ding, Xingwu

    2013-01-01

    Highlights: • Bimodal elastomeric NBR as a new material was developed. • The structure of bimodal elastomeric NBR networks was determined. • The relationship between structure and mechanical properties was investigated. • The tribological properties and mechanisms of bimodal NBR were analyzed. • The benefits of bimodal NBR in the field of tribology were discussed. - Abstract: Bimodal nitrile butadiene rubber (NBR) was examined in this study. The molecular structure was determined by dynamic mechanical analysis and transmission electron microscopy. The relationship between the structure and the mechanical properties related to elastomeric tribological properties was investigated. The properties and the mechanisms of friction and wear of bimodal elastomeric NBR networks were also analyzed. The lubricating characteristics of bimodal NBR networks were revealed based on the mechanisms of friction and wear. Results show that bimodal NBR networks are similar to bimodal polydimethylsiloxane networks. The form and density of the network structure can be controlled from elastomeric networks to thermosetting resin networks. The mechanical properties of bimodal NBR networks, such as elasticity, elongation at break, fatigue characteristic, tensile strength, elastic modulus, and thermal stability can be precisely controlled following the variation in network structure. The friction, wear, and lubrication of bimodal NBR networks can be clearly described according to the principles of tribology. Common elastomers cannot simultaneously reduce friction and wear because of the different mechanisms of friction and wear; however, bimodal elastomer networks can efficiently address this problem

  20. The role of elastomeric pumps in postoperative analgesia in orthopaedics and factors affecting their flow rate.

    Science.gov (United States)

    Theodorides, Anthony Andreas

    2017-12-01

    Elastomeric pumps are mechanical devices composed of an elastomeric balloon reservoir into which the drug to be infused is stored, a protective casing (used by some manufacturers), a flow controller and a wound catheter. In orthopaedics they are used to provide continuous local infiltration analgesia. In this way patients rely less on other routes of analgesia and thus avoid their systemic side effects. Studies have shown good response to analgesia with these pumps for the first 24 hours but their benefit is not as clear at 48 and 72 hours. There are numerous factors that affect the flow rate of elastomeric pumps. Some are inherent to all elastomeric pumps such as: the pressure exerted by the elastomeric balloon, catheter size, the vertical height of the pump in relation to the wound, viscosity and partial filling. There are also other factors which vary according to the manufacturer such as: the optimal temperature to obtain the desired flow rate as this directly affects viscosity, the dialysate that the analgesic drug is mixed with (ie normal saline or 5% dextrose), and the storage conditions of the fluid to be infused. It is thus essential to follow the clinical guidelines provided by the manufacturer in order to obtain the desired flow rate. Copyright the Association for Perioperative Practice.

  1. Force decay of elastomeric chains - a mechanical design and product comparison study.

    Science.gov (United States)

    Balhoff, David A; Shuldberg, Matthew; Hagan, Joseph L; Ballard, Richard W; Armbruster, Paul C

    2011-03-01

    To evaluate the percentage force decay of elastomeric chain products utilizing three different design mechanisms simulating canine retraction; and to evaluate the percentage force decay of elastomeric chain products from four different companies. In vitro, laboratory study. LSUHSC Dental School, New Orleans, LA, USA. Closed (non-spaced), grey elastomeric chains from four companies were selected for the study. Three acrylic resin jigs were constructed to provide a framework for three simulated space closure mechanisms. The 6-5-3, the chain loop, and the 6-3 were the configuration mechanisms used in the study. An electronic force gauge was used to measure the percentage force decay associated with each elastomeric chain over 28 days at preselected times. There was a significant difference in the mean percentage force decay for the three different mechanisms (P < 0·001). For all four companies, the 6-3 mechanical design had the smallest mean percentage force decay. There was a significant difference in the mean percentage force decay for the different companies (P < 0·001). For all three mechanisms, Ormco had the smallest percentage force decay while Unitek had the highest percentage force decay. The significant difference in the mean percentage force decay for the different mechanisms suggests that the 6-3 design is a more efficient means of closing extraction spaces utilizing elastomeric chains.

  2. Patch photopatch test at Manipal

    Directory of Open Access Journals (Sweden)

    Panja Arindrajit

    1994-01-01

    Full Text Available Patch and photopatch testing was performed on 55 patients with history of photosensitivity using Scandanavian photo patch test antigens obtained from Chemotechnique Diagnostics AB Sweden. The commonest reactions were seen to perfume mix 4 (21.0%, PABA 3 (15.78%, promethazine hydrochloride 3 (15.78%, chlorpromazine hydrochloride 3 (15.78%, balsam of peru 2 (10.52%, usnic acid, hexachlorophane, musk ambrette and 6 methyl coumarin showed 1 positive reaction each (5.26% suggesting either phototoxicity or photo sensitization. Patch and photo patch test positive reaction suggesting allergic sensitisation was seen to balsam of peru 3 (23.0% perfume mix 3 (23.0% promethazine hydrochloride 2 (15.3% and PABA, 6 methyl coumarin, tribromosalicylanilide, atranorin and wood mix showed positive reaction in one case each (7.69%. We conclude that photoxic or photo allergic reaction is a problem in India and patch photo patch test should be performed in all cases of idiopathic light eruptions to rule out photo sensitisation and in cases where photo sensitivity of exogenous origin is suspected.

  3. Adequate plasma drug concentrations suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps.

    Science.gov (United States)

    Arensdorff, Lyne; Boillat-Blanco, Noémie; Decosterd, Laurent; Buclin, Thierry; de Vallière, Serge

    2017-09-01

    Elastomeric pumps can be useful for the administration of antibiotics in the outpatient setting. To determine amoxicillin degradation in elastomeric pumps, as well as the effectiveness of amoxicillin treatment administered by elastomeric pumps. Antibiotic degradation was measured in elastomeric pumps filled with 6 g of amoxicillin in 240 mL of NaCl 0.9% by drawing samples at 12 h intervals when stored in the fridge for 48 h and when worn around the waist for 24 h. Subsequently nine patients were treated with continuous infusions of 8 or 12 g of amoxicillin per day. Plasma amoxicillin concentrations were measured on each visit to the outpatient parenteral antibiotic therapy unit. Clinical outcome was verified 3 months after the end of treatment. Amoxicillin degradation in elastomeric pumps reached 10% after 48 h in the fridge and an additional 30% when worn around the waist for 24 h. Mean plasma drug concentrations achieved with 12 g of amoxicillin per day were 18.5 mg/L (95% CI 13.5-23.5), which is largely above the MIC of amoxicillin-susceptible bacteria. Nine patients treated for various complicated infections were cured and had no unexpected adverse effects. Adequate plasma drug concentrations and favourable clinical outcomes suggest that amoxicillin can be administered by continuous infusion using elastomeric pumps. This treatment modality does not fulfil formal requirements regarding pharmaceutical stability, but the resulting safety impact in patients is probably limited. Therapeutic drug monitoring and a close clinical follow-up are recommended if this route of administration is chosen. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Baxter elastomeric pumps: Weighing as an alternative to visual inspection.

    Science.gov (United States)

    Cusano, Ellen L; Ali, Raafi; Sawyer, Michael B; Chambers, Carole R; Tang, Patricia A

    2018-04-01

    Purpose Elastomeric pumps are used to administer 46-hour infusions of 5-fluorouracil (5FU). Baxter suggests patients visually monitor their pumps to ensure that infusions are proceeding correctly. This can be confusing and lead to concerns about under- or over-dosing. Baxter has not considered weighing pumps as a validated method for monitoring. This study aims to validate weighing as a more accurate method for patients and healthcare professionals, and describe real life Baxter Infusor™ variability. Methods Patients who had been started on a 46-hour 5FU infusion returned to the clinic approximately 24 h after starting treatment. The pump was weighed on a StarFrit kitchen scale, and date, time, and weights recorded. Patients were asked if they had a preference for weighing or visually inspecting their pump. Results Pumps ( n = 103) were weighed between 17.25 and 27.5 h after connection. The average weight of a pump was 189 g. Of 103 pumps weighed, 99 weighed less than expected, corresponding to average flow rates of 5.69 mL/h over the elapsed time. The expected flow rate is 5 mL/h with 10% variability. Average flow rates within the 17.25- to 27.5-hour window were 4.561 mL/h, which is 8.78% slower than expected, but within the 10% known variability. Forty-seven percent of patients didn't have a preference for either method, but for those who did have a preference, more than twice as many preferred weighing. Conclusion With proper education, weighing Baxter Infusors at home with kitchen scales can be an accepted and objective alternative to the current recommendation of visual inspection.

  5. Effect of storage period on the accuracy of elastomeric impressions

    Directory of Open Access Journals (Sweden)

    Eduardo Batista Franco

    2007-06-01

    Full Text Available AIMS: To investigate the effect of the storage period on the accuracy of recently developed elastomeric materials. METHODS: Simultaneous impressions of a steel die were taken using a polyether (I: Impregum Soft Heavy and Light body, 3M ESPE and vinyl polysiloxane (P: Perfectim Blue Velvet and Flexi-Velvet, J.Morita. The trays were loaded with the heavy-bodied impression materials while the light-bodied impression materials were simultaneously spread on the steel die. The impressions were poured after 2 hours, 24 hours, and 7 days. Impressions were stored at approximately 55% relative humidity and room temperature. Ten replicas were produced for each experimental condition (n=60. Accuracy of the stone dies was assessed with a depth-measuring microscope. The difference in height between the surface of the stone die and a standard metallic ring was recorded in micrometers at four demarcated points, by two independent examiners. Data were submitted to two-way ANOVA and Tukey test (a = 0.05. RESULTS: Significant differences were found among the groups. Smaller discrepancies were observed when pouring was performed up to 24 hours (I-2h= 65.0 ± 15.68 µm; I-24h= 81.6 ± 11.13 µm for the polyether, and up to 7 days for the vinyl polysiloxane (P-2h= 79.1 ± 13.82 µm; P-24h= 96.8 ± 6.02 µm; P-7d= 81.4 ± 4.3 µm. Significant dimensional discrepancies, however, were observed when polyether was stored for 7 days (I-7d= 295.3 ± 17.4 µm. CONCLUSION: Storage may significantly affect the dimensional accuracy of impressions and, thus, a maximum period and storage condition should be specified for the recently developed materials.

  6. Biomaterials for drug delivery patches.

    Science.gov (United States)

    Santos, Lúcia F; Correia, Ilídio J; Silva, A Sofia; Mano, João F

    2018-06-15

    The limited efficiency of conventional drugs has been instigated the development of new and more effective drug delivery systems (DDS). Transdermal DDS, are associated with numerous advantages such its painless application and less frequent replacement and greater flexibility of dosing, features that triggered the research and development of such devices. Such systems have been produced using either biopolymer; or synthetic polymers. Although the first ones are safer, biocompatible and present a controlled degradation by human enzymes or water, the second ones are the most currently available in the market due to their greater mechanical resistance and flexibility, and non-degradation over time. This review highlights the most recent advances (mainly in the last five years) of patches aimed for transdermal drug delivery, focusing on the different materials (natural, synthetic and blends) and latest designs for the development of such devices, emphasizing also their combination with drug carriers that enable enhanced drug solubility and a more controlled release of the drug over the time. The benefits and limitations of different patches formulations are considered with reference to their appliance to transdermal drug delivery. Furthermore, a record of the currently available patches on the market is given, featuring their most relevant characteristics. Finally, a list of most recent/ongoing clinical trials regarding the use of patches for skin disorders is detailed and critical insights on the current state of patches for transdermal drug delivery are also provided. Copyright © 2018. Published by Elsevier B.V.

  7. Investigation of Pre- and Post-Swelling Behavior of Elastomeric Material

    Directory of Open Access Journals (Sweden)

    M Akhtar

    2013-06-01

    Full Text Available In the last ten years, a new type of modern polymer, known as swelling elastomer, has been used extensively as a sealing element in the oil and gas industry. These elastomers have been instrumental in various new applications such as water shut off, zonal isolation, and sidetracking. Though swell packers can significantly reduce costs and increase productivity, their failure can lead to serious losses. The integrity and reliability of swelling elastomer seals under different field conditions is a major concern. The investigation of changes in material behavior over a specified swelling period is a necessary first step for performance evaluation of elastomer seals. The current study is based on experimental analysis of changes in geometric and mechanical behavior (hardness, tensile, compressive, bulk of an elastomeric material due to swelling. Tests were carried out before and after various stages of swelling. Specimens were placed in saline water (0.6% and 12% concentrations at a temperature of 50°C, with the total swelling period being one month. Swelling, hardness, compression, and bulk tests were conducted using disc samples, while ring samples were used for tensile experiments. A small test rig was designed and constructed for determination of bulk modulus. Stress-strain curves under tension and compression, and pressure volumetric-strain curves were obtained for specimens subjected to different swelling periods. Due to the fast-swell nature of the elastomer, there were sharp changes in mechanical properties within the first few days of swelling for both salinities. Elastic modulus derived from tensile and compressive tests showed a 90% decrease in the first few days. Bulk modulus showed fluctuation in its variation with an increasing swelling period. There was a small effect of salinity only during the first 5 or 6 days.

  8. On propagation of axisymmetric waves in pressurized functionally graded elastomeric hollow cylinders

    Science.gov (United States)

    Wu, Bin; Su, Yipin; Liu, Dongying; Chen, Weiqiu; Zhang, Chuanzeng

    2018-05-01

    Soft materials can be designed with a functionally graded (FG) property for specific applications. Such material inhomogeneity can also be found in many soft biological tissues whose functionality is only partly understood to date. In this paper, we analyze the axisymmetric guided wave propagation in a pressurized FG elastomeric hollow cylinder. The cylinder is subjected to a combined action of axial pre-stretch and pressure difference applied to the inner and outer cylindrical surfaces. We consider both torsional waves and longitudinal waves propagating in the FG cylinder made of incompressible isotropic elastomer, which is characterized by the Mooney-Rivlin strain energy function but with the material parameters varying with the radial coordinate in an affine way. The pressure difference generates an inhomogeneous deformation field in the FG cylinder, which dramatically complicates the superimposed wave problem described by the small-on-large theory. A particularly efficient approach is hence employed which combines the state-space formalism for the incremental wave motion with the approximate laminate or multi-layer technique. Dispersion relations for the two types of axisymmetric guided waves are then derived analytically. The accuracy and convergence of the proposed approach is validated numerically. The effects of the pressure difference, material gradient, and axial pre-stretch on both the torsional and the longitudinal wave propagation characteristics are discussed in detail through numerical examples. It is found that the frequency of axisymmetric waves depends nonlinearly on the pressure difference and the material gradient, and an increase in the material gradient enhances the capability of the pressure difference to adjust the wave behavior in the FG cylinder. This work provides a theoretical guidance for characterizing FG soft materials by in-situ ultrasonic nondestructive evaluation and for designing tunable waveguides via material tailoring along

  9. *NEW* CRITICAL Windows Security patches

    CERN Multimedia

    2003-01-01

    On 3 October and 10 September 2003, Microsoft issued new CRITICAL security patches MS03-040 and MS03-039. They must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security holes and patches are at: MS03-039: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp MS03-040: http://cern.ch/it-div/news/hotfix-MS03-040.asp http://www.microsoft.com/technet/security/bulletin/MS03-040.asp

  10. A large-scale deforestation experiment: Effects of patch area and isolation on Amazon birds

    Science.gov (United States)

    Ferraz, G.; Nichols, J.D.; Hines, J.E.; Stouffer, P.C.; Bierregaard, R.O.; Lovejoy, T.E.

    2007-01-01

    As compared with extensive contiguous areas, small isolated habitat patches lack many species. Some species disappear after isolation; others are rarely found in any small patch, regardless of isolation. We used a 13-year data set of bird captures from a large landscape-manipulation experiment in a Brazilian Amazon forest to model the extinction-colonization dynamics of 55 species and tested basic predictions of island biogeography and metapopulation theory. From our models, we derived two metrics of species vulnerability to changes in isolation and patch area. We found a strong effect of area and a variable effect of isolation on the predicted patch occupancy by birds.

  11. The effect of dietary pigmentation on the esthetic appearance of clear orthodontic elastomeric modules

    Directory of Open Access Journals (Sweden)

    Nabeel F Talic

    2016-01-01

    Conclusions: Coffee and tea are strong staining media that should be avoided by patients who opted to have esthetic appliances for their orthodontic treatment. Elastomeric modules manufactured by AU showed higher staining optical properties as compared to the other two companies, which could be related to the manufacturing processing of these modules.

  12. Physical and Chemical Stability of Urapidil in 0.9% Sodium Chloride in Elastomeric Infusion Pump.

    Science.gov (United States)

    Tomasello, Cristina; Leggieri, Anna; Rabbia, Franco; Veglio, Franco; Baietto, Lorena; Fulcheri, Chiara; De Nicolò, Amedeo; De Perri, Giovanni; D'Avolio, Antonio

    2016-01-01

    Urapidil is an antihypertensive agent, usually administered through intravenous bolus injection, slow-intravenous infusion, or continuous-drug infusion by perfusor. Since to date no evidences are available on drug stability in elastomeric pumps, patients have to be hospitalized. The purpose of this study was to validate an ultra-performance liquid chromatographic method to evaluate urapidil stability in an elastomeric infusion pump, in order to allow continuous infusion as home-care treatment. Analyses were conducted by diluting urapidil in an elastomeric pump. Two concentrations were evaluated: 1.6 mg/mL and 3.3 mg/mL. For the analyses, a reverse-phase ultra-performance liquid chromatographic- photodiode array detection instrument was used. Stressed degradation, pH changes, and visual clarity were used as stability indicators up to 10 days after urapidil solution preparation. The drug showed no more than 5% degradation during the test period at room temperature. No pH changes and no evidences of incompatibility were observed. Stress tests resulted in appreciable observation of degradation products. Considering the observed mean values, urapidil hydrochloride in sodium chloride 0.9% in elastomeric infusion pumps is stable for at least 10 days. These results indicate that this treatment could be administered at home for a prolonged duration (at least 7 days) with a satisfactory response. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  13. Mate choice when males are in patches: optimal strategies and good rules of thumb.

    Science.gov (United States)

    Hutchinson, John M C; Halupka, Konrad

    2004-11-07

    In standard mate-choice models, females encounter males sequentially and decide whether to inspect the quality of another male or to accept a male already inspected. What changes when males are clumped in patches and there is a significant cost to travel between patches? We use stochastic dynamic programming to derive optimum strategies under various assumptions. With zero costs to returning to a male in the current patch, the optimal strategy accepts males above a quality threshold which is constant whenever one or more males in the patch remain uninspected; this threshold drops when inspecting the last male in the patch, so returns may occur only then and are never to a male in a previously inspected patch. With non-zero within-patch return costs, such a two-threshold rule still performs extremely well, but a more gradual decline in acceptance threshold is optimal. Inability to return at all need not decrease performance by much. The acceptance threshold should also decline if it gets harder to discover the last males in a patch. Optimal strategies become more complex when mean male quality varies systematically between patches or years, and females estimate this in a Bayesian manner through inspecting male qualities. It can then be optimal to switch patch before inspecting all males on a patch, or, exceptionally, to return to an earlier patch. We compare performance of various rules of thumb in these environments and in ones without a patch structure. A two-threshold rule performs excellently, as do various simplifications of it. The best-of-N rule outperforms threshold rules only in non-patchy environments with between-year quality variation. The cutoff rule performs poorly.

  14. Effect of Commonly Used Beverage, Soft Drink, and Mouthwash on Force Delivered by Elastomeric Chain: A Comparative In Vitro Study

    OpenAIRE

    Kumar, Kiran; Shetty, Sharath; Krithika, M J; Cyriac, Bobby

    2014-01-01

    Background: The objective was to evaluate and compare the effect of Coca-Cola®, tea, Listerine® mouthwash on the force delivered by elastomeric chain in vitro. Materials and Methods: Four specimen groups (distilled water, Coca-Cola®, tea, Listerine® mouthwash) with a total sample size of 480 specimens. A specimen is described as a four link grey close elastomeric chain. Jigs, each with a series of pins set 25 mm apart, was used to hold stretched elastomeric chains at a...

  15. The flow Rate Accuracy of Elastomeric Infusion Pumps After Repeated Filling.

    Science.gov (United States)

    Mohseni, Masood; Ebneshahidi, Amin

    2014-05-01

    One of the frequent applications of elastomeric infusion pumps is postoperative pain management. In daily practice, the disposable pumps get refilled with modified medication combinations in the successive days; although, the accuracy of infusion rates is unknown to clinicians. Our aim was to evaluate the effect of repeated filling on the delivery rate accuracy of an elastomeric pump available in our market. We examined 10 elastomeric infusion pumps (BOT-802, Nanchang Biotek Medical Device Company, China) with 100 mL capacity and nominal flow of 5 mL/h. Each pump was filled for three times, accounting for 30 series of experiments. A microset scaled in mL was used to measure the pump deliveries. Flow profile and reliability of infusion rate were analyzed after repeated use. The mean flow rate in the three series of measurements showed a gradual increase; however, the difference was not statistically significant (5.01 ± 0.07 vs. 5.03 ± 0.06 vs. 5.06 ± 0.08 mL/h; P = 0.81). The percentage of the flow rate error (deviation from 5 mL/h ± 15%) was 100% in the first and second hours of infusion, 96% in the third hour, 60% in the 20th hour and zero percent in the rest of the infusion time. This study indicated that the delivery rate accuracy of elastomeric infusion pumps is preserved after repeated usage. These laboratory findings suggested that elastomeric pumps could be safely refilled in the successive days to provide postoperative analgesia.

  16. Patching the Exchange-Correlation Potential in Density Functional Theory.

    Science.gov (United States)

    Huang, Chen

    2016-05-10

    A method for directly patching exchange-correlation (XC) potentials in materials is derived. The electron density of a system is partitioned into subsystem densities by dividing its Kohn-Sham (KS) potential among the subsystems. Inside each subsystem, its projected KS potential is required to become the total system's KS potential. This requirement, together with the nearsightedness principle of electronic matters, ensures that the electronic structures inside subsystems can be good approximations to the total system's electronic structure. The nearsightedness principle also ensures that subsystem densities could be well localized in their regions, making it possible to use high-level methods to invert the XC potentials for subsystem densities. Two XC patching methods are developed. In the local XC patching method, the total system's XC potential is improved in the cluster region. We show that the coupling between a cluster and its environment is important for achieving a fast convergence of the electronic structure in the cluster region. In the global XC patching method, we discuss how to patch the subsystem XC potentials to construct the XC potential in the total system, aiming to scale up high-level quantum mechanics simulations of materials. Proof-of-principle examples are given.

  17. Patch layout generation by detecting feature networks

    KAUST Repository

    Cao, Yuanhao; Yan, Dongming; Wonka, Peter

    2015-01-01

    The patch layout of 3D surfaces reveals the high-level geometric and topological structures. In this paper, we study the patch layout computation by detecting and enclosing feature loops on surfaces. We present a hybrid framework which combines

  18. Evaluation of concrete pavement patching techniques.

    Science.gov (United States)

    1989-01-01

    This final report presents the results of a study undertaken to improve in concrete pavement patching techniques. Activities included an evaluation of the suitability of the impact hammer and maturity calculations for determining when a patch is read...

  19. Streamlining of plant patches in streams

    DEFF Research Database (Denmark)

    Jensen, Kaj Sand; Pedersen, Morten Lauge

    2008-01-01

    . Sediment elevation within patches (avg. 4.1 cm) increased significantly with patch length, but did not differ between unstable sand or more stable coarse sediment for the same patch length. Shape of canopy and root area did not change significantly with sediment type. 4. Pressure drag on the canopy...

  20. Patching. Restitching business portfolios in dynamic markets.

    Science.gov (United States)

    Eisenhardt, K M; Brown, S L

    1999-01-01

    In turbulent markets, businesses and opportunities are constantly falling out of alignment. New technologies and emerging markets create fresh opportunities. Converging markets produce more. And of course, some markets fade. In this landscape of continuous flux, it's more important to build corporate-level strategic processes that enable dynamic repositioning than it is to build any particular defensible position. That's why smart corporate strategists use patching, a process of mapping and remapping business units to create a shifting mix of highly focused, tightly aligned businesses that can respond to changing market opportunities. Patching is not just another name for reorganizing; patchers have a distinctive mindset. Traditional managers see structure as stable; patching managers believe structure is inherently temporary. Traditional managers set corporate strategy first, but patching managers keep the organization focused on the right set of business opportunities and let strategy emerge from individual businesses. Although the focus of patching is flexibility, the process itself follows a pattern. Patching changes are usually small in scale and made frequently. Patching should be done quickly; the emphasis is on getting the patch about right and fixing problems later. Patches should have a test drive before they're formalized but then be tightly scripted after they've been announced. And patching won't work without the right infrastructure: modular business units, fine-grained and complete unit-level metrics, and companywide compensation parity. The authors illustrate how patching works and point out some common stumbling blocks.

  1. Is static friction affected by aging and amount of elastomeric ligatures in orthodontic sliding mechanics? An in-vitro investigation.

    Science.gov (United States)

    Lo Giudice, A; Portelli, M; Militi, A; Spinuzza, P; Bellocchio, A M; Nucera, R; Marcolina, M; Ghilardi, G; Manuelli, M; Lucchese, A

    2018-03-15

    In straight-wire mechanics, friction can significantly influence the forces expressed by wires. The aim of this study is to assess whether the aging and the sum of elastomeric ligatures affect the static friction during orthodontic space closure. A 0.017x 0.025-in SS was drawn throughout a 3-bracket experimental model and engaged with elastomeric ligatures. Before performing the test, the ligatures were soaked in artificial saliva for 48 hours (Group 1), 2 weeks (Group 2) and 4 weeks (Group 3); brand-new ligatures were also tested as control group (Group 4). The resistance to sliding (RS) was recorded at 3 different numerical configurations of ligatures using a customized testing machine and tests were repeated for ten times. Data of RS were statistically analysed by using two way analysis of variance (ANOVA) and Tukey’s multiple comparison tests. RS was found to increase systematically when more elastomeric ligatures were included in the wire engaging system. At two weeks of immersion in artificial saliva elastomeric ligatures showed the lowest values of RS while they became significantly more frictional after immersion for 4 weeks. The results of this study showed that in multi-bracket orthodontic therapy, the RS increases with the number of elastomeric ligatures involved for arch-wire engagement. Differently from the frictional behavior of elastomeric modules, the aging of these ligatures does not influence their incremental effect of frictional forces.

  2. Sensitivity improvement of a fibre Bragg grating pH sensor with elastomeric coating

    Science.gov (United States)

    Yulianti, Ian; Supa'at, A. S. M.; Idrus, Sevia M.; Kurdi, Ojo; Anwar, M. R. S.

    2012-01-01

    A new optical pH sensor based on fibre Bragg grating (FBG) is demonstrated. The sensor consists of a FBG coated with pH sensitive hydrogel. The sensing was performed through the detection of wavelength shifts resulting from the induced strain on the FBG due to mechanical expansion of the hydrogel. An elastomeric coating was applied before the hydrogel coating to improve the sensitivity. The sensor performance was investigated by simulating the hydrogel swelling and the strain induced on the FBG. The swelling of hydrogel due to pH change was modelled using a free-energy function and was solved using the finite element method. With silicone rubber as the elastomer material, the results show that the sensitivity was improved by up to 66% compared to that of the FBG pH sensor without elastomeric coating.

  3. Sensitivity improvement of a fibre Bragg grating pH sensor with elastomeric coating

    International Nuclear Information System (INIS)

    Yulianti, Ian; Supa'at, A S M; Idrus, Sevia M; Anwar, M R S; Kurdi, Ojo

    2012-01-01

    A new optical pH sensor based on fibre Bragg grating (FBG) is demonstrated. The sensor consists of a FBG coated with pH sensitive hydrogel. The sensing was performed through the detection of wavelength shifts resulting from the induced strain on the FBG due to mechanical expansion of the hydrogel. An elastomeric coating was applied before the hydrogel coating to improve the sensitivity. The sensor performance was investigated by simulating the hydrogel swelling and the strain induced on the FBG. The swelling of hydrogel due to pH change was modelled using a free-energy function and was solved using the finite element method. With silicone rubber as the elastomer material, the results show that the sensitivity was improved by up to 66% compared to that of the FBG pH sensor without elastomeric coating

  4. Effects of atmospheric pressure conditions on flow rate of an elastomeric infusion pump.

    Science.gov (United States)

    Wang, Jong; Moeller, Anna; Ding, Yuanpang Samuel

    2012-04-01

    The effects of pressure conditions, both hyperbaric and hypobaric, on the flow rate of an elastomeric infusion pump were investigated. The altered pressure conditions were tested with the restrictor outlet at two different conditions: (1) at the same pressure condition as the Infusor elastomeric balloon and (2) with the outlet exposed to ambient conditions. Five different pressure conditions were tested. These included ambient pressure (98-101 kilopascals [kPa]) and test pressures controlled to be 10 or 20 kPa below or 75 or 150 kPa above the ambient pressure. A theoretical calculation based on the principles of fluid mechanics was also used to predict the pump's flow rate at various ambient conditions. The conditions in which the Infusor elastomeric pump and restrictor outlet were at the same pressure gave rise to average flow rates within the ±10% tolerance of the calculated target flow rate of 11 mL/hr. The flow rate of the Infusor pump decreased when the pressure conditions changed from hypobaric to ambient. The flow rate increased when the pressure conditions changed from hyperbaric to ambient. The flow rate of the Infusor elastomeric pump was not affected when the balloon reservoir and restrictor outlet were at the same pressure. The flow rate varied from 58.54% to 377.04% of the labeled flow rate when the pressure applied to the reservoir varied from 20 kPa below to 150 kPa above the pressure applied to the restrictor outlet, respectively. The maximum difference between observed flow rates and those calculated by applying fluid mechanics was 4.9%.

  5. Hybrid magnetorheological fluid–elastomeric lag dampers for helicopter stability augmentation

    International Nuclear Information System (INIS)

    Hu Wei; Wereley, Norman M

    2008-01-01

    A laboratory demonstration of a hybrid magnetorheological fluid–elastomeric (MRFE) damper is investigated for adjustable or programmable lag mode damping in helicopters, so that damping requirements can be varied as a function of different flight conditions. The laboratory demonstration of this hybrid MRFE lag damper consists of a double lap shear elastomeric damper in parallel with two magnetorheological (MR) flow mode dampers. This is compared to a damper where only elastomeric materials are implemented, i.e., a double lap shear specimen. The relationship between the output force and the quasi-steady harmonic displacement input to a flow mode MR damper is exploited, where the output force can be adjusted as a function of applied magnetic field. Equivalent viscous damping is used to compare the damping characteristics of the hybrid damper to a conventional elastomeric damper under steady-state sinusoidal displacement excitation. To demonstrate feasibility, a hybrid MRFE damper test setup is designed, and single frequency (lag frequency or rotor in-plane bending frequency) and dual frequency (lag frequency and rotor frequency) tests are conducted under different magnetic fields. The hybrid MRFE damper exhibits amplitude-dependent damping behavior. However, with application of a magnetic field, the damping level is controlled to a specific damping level objective as a function of displacement amplitude. Similarly, under dual frequency conditions, damping degradation at the lag frequency, because of lag motion at the rotor frequency, can also be recovered by increasing magnetic field. A time-domain analysis is developed to study the nonlinear dynamic behavior of the hybrid MRFE damper. Using rate-dependent elasto-slides, the amplitude-dependent behavior of the hybrid MRFE damper is accurately reconstructed using both constant and current-dependent (i.e. controllable) parameters. The analysis is physically motivated and can be applied to the elastomer and MR fluid

  6. Antibiotic stability related to temperature variations in elastomeric pumps used for outpatient parenteral antimicrobial therapy (OPAT).

    Science.gov (United States)

    Voumard, Rachel; Van Neyghem, Niklas; Cochet, Camille; Gardiol, Céline; Decosterd, Laurent; Buclin, Thierry; de Valliere, Serge

    2017-05-01

    Elastomeric pumps can be used for the continuous administration of antimicrobials in the outpatient setting. A potentially limiting factor in their use is the stability of antimicrobials. To investigate under real-life conditions the temperature variations of antibiotic solutions contained in elastomeric pumps, and to examine under such conditions the stability of five antibiotics. Healthy volunteers carried the elastomeric pumps in carry pouches during their daily activities. A thermologger measured the temperatures every 15 min over 24 h. Antibiotic concentrations were measured by HPLC coupled to tandem MS. During daytime, the temperature of solutions in the pumps increased steadily, warming to >30°C. During the night, when the pumps were kept attached to the waist, the temperatures reached up to 33°C. The use of white carry pouches avoided excessive temperature increases. Over seven experiments, cefazolin, cefepime, piperacillin and tazobactam were found to be stable over 24 h. Flucloxacillin showed a mean decrease in concentration of 11% ( P  = 0.001). Real-life situations can cause significant temperature rises in elastomeric pumps, thereby potentially increasing the risk of antibiotic degradation. Patients should be instructed to avoid situations causing excessive temperature increases. Despite these temperature variations, cefazolin, cefepime, piperacillin and tazobactam were found to be stable over 24 h. A moderate degradation was noticed for flucloxacillin, albeit most probably not to an extent that might impair anti-infective efficacy. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo

    2006-03-01

    The objective was to compare the frictional forces generated by new nonconventional passive elastomeric ligatures (NCL) and conventional elastomeric ligatures (CL) under dry conditions. An experimental model reproducing the right buccal segment of the upper arch and consisting of five stainless steel 0.022-inch preadjusted brackets (from the second premolar through the central incisor) was used to assess both static and kinetic frictional forces produced by NCL and CL. The frictional forces generated by the 0.019 x 0.025-inch stainless steel wire with the two types of elastomeric ligatures were recorded by sliding the wire into the aligned brackets. The friction produced by the 0.014-inch superelastic nickel titanium wire was evaluated both in the presence of aligned brackets and of three-mm misaligned canine bracket. The amount of both static and kinetic frictions were minimal (<10 g) in the NCL group in the presence of aligned brackets with both types of wires, whereas it ranged from a minimum of 95.6 g for the 0.014-inch superelastic nickel titanium wire to a maximum of 590.7 g for the 0.019 x 0.025-inch stainless steel wire when using CL. The amount of both static and kinetic frictions in the presence of a misaligned canine bracket in the NCL group were less than half of that shown by the CL group. A recently developed passive ligature system is able to produce significantly lower levels of frictional forces in vitro when compared with conventional elastomeric modules.

  8. Long-term analysis of ionospheric polar patches based on CHAMP TEC data

    DEFF Research Database (Denmark)

    Noja, M.; Stolle, Claudia; Park, J.

    2013-01-01

    Total electron content (TEC) from LEO satellites offers great possibility to sound the upper ionosphere and plasmasphere. This paper describes a method to derive absolute TEC observations aboard CHAMP considering multipath effects and receiver differential code bias. The long-term data set of 9...... years GPS observations is used to investigate the climatological behavior of high-latitude plasma patches in both hemispheres. The occurrence of polar patches has a clear correlation with the solar cycle, which is less pronounced in the Southern Hemisphere (SH). Summed over all years, we observed...... a higher number of patches in the SH. The maximum occurrence rate of patches has been found at the dayside polar cusp during 12:00-18:00 MLT (magnetic local time) supporting the mechanisms for patch creation by local particle precipitation and by intrusion of subauroral plasma into the polar cap through...

  9. Elastomeric Dampers Derived From First-Principles-Based Analytical Simulation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The lead-lag motions of rotor blades in a helicopter require damping to stabilize them. In practice, this has necessitated the use of external hydraulic dampers...

  10. Elastomeric Dampers derived from First-Principles-Based Analytical Simulation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Lead-lag motions of rotor blades in helicopters require damping to stabilize them. In practice, this has necessitated the use of external hydraulic dampers which...

  11. In silico simulation and in vitro evaluation of an elastomeric scaffold using ultrasonic shear wave imaging

    Science.gov (United States)

    Yu, Jiao; Nie, Erwei; Zhu, Yanying; Hong, Yi

    2018-03-01

    Biodegradable elastomeric scaffolds for soft tissue repair represent a growing area of biomaterials research. Mechanical strength is one of the key factors to consider in the evaluation of candidate materials and the designs for tissue scaffolds. It is desirable to develop non-invasive evaluation methods of the mechanical property of scaffolds which would provide options for monitoring temporal mechanical property changes in situ. In this paper, we conduct in silico simulation and in vitro evaluation of an elastomeric scaffold using a novel ultrasonic shear wave imaging (USWI). The scaffold is fabricated from a biodegradable elastomer, poly(carbonate urethane) urea using salt leaching method. A numerical simulation is performed to test the robustness of the developed inversion algorithm for the elasticity map reconstruction which will be implemented in the phantom experiment. The generation and propagation of shear waves in a homogeneous tissue-mimicking medium with a circular scaffold inclusion is simulated and the elasticity map is well reconstructed. A PVA phantom experiment is performed to test the ability of USWI combined with the inversion algorithm to non-invasively characterize the mechanical property of a porous, biodegradable elastomeric scaffold. The elastic properties of the tested scaffold can be easily differentiated from the surrounding medium in the reconstructed image. The ability of the developed method to identify the edge of the scaffold and characterize the elasticity distribution is demonstrated. Preliminary results in this pilot study support the idea of applying the USWI based method for non-invasive elasticity characterization of tissue scaffolds.

  12. Puncture mechanics of soft elastomeric membrane with large deformation by rigid cylindrical indenter

    Science.gov (United States)

    Liu, Junjie; Chen, Zhe; Liang, Xueya; Huang, Xiaoqiang; Mao, Guoyong; Hong, Wei; Yu, Honghui; Qu, Shaoxing

    2018-03-01

    Soft elastomeric membrane structures are widely used and commonly found in engineering and biological applications. Puncture is one of the primary failure modes of soft elastomeric membrane at large deformation when indented by rigid objects. In order to investigate the puncture failure mechanism of soft elastomeric membrane with large deformation, we study the deformation and puncture failure of silicone rubber membrane that results from the continuous axisymmetric indentation by cylindrical steel indenters experimentally and analytically. In the experiment, effects of indenter size and the friction between the indenter and the membrane on the deformation and puncture failure of the membrane are investigated. In the analytical study, a model within the framework of nonlinear field theory is developed to describe the large local deformation around the punctured area, as well as to predict the puncture failure of the membrane. The deformed membrane is divided into three parts and the friction contact between the membrane and indenter is modeled by Coulomb friction law. The first invariant of the right Cauchy-Green deformation tensor I1 is adopted to predict the puncture failure of the membrane. The experimental and analytical results agree well. This work provides a guideline in designing reliable soft devices featured with membrane structures, which are present in a wide variety of applications.

  13. Preliminary SEM Observations on the Surface of Elastomeric Impression Materials after Immersion or Ozone Disinfection

    Science.gov (United States)

    Prombonas, Anthony; Yannikakis, Stavros; Karampotsos, Thanasis; Katsarou, Martha-Spyridoula; Drakoulis, Nikolaos

    2016-01-01

    Introduction Surface integrity of dental elastomeric impression materials that are subjected to disinfection is of major importance for the quality of the final prosthetic restorations. Aim The aim of this qualitative Scanning Electronic Microscopy (SEM) study was to reveal the effects of immersion or ozone disinfection on the surface of four dental elastomeric impression materials. Materials and Methods Four dental elastomeric impression material brands were used (two vinyl polysiloxane silicones, one polyether, and one vinyl polyether silicone). Total of 32 specimens were fabricated, eight from each impression material. Specimens were immersion (0.525% sodium hypochlorite solution or 0.3% benzalkonium chloride solution) or ozone disinfected or served as controls and examined with SEM. Results Surface degradation was observed on several speci-mens disinfected with 0.525% sodium hypochlorite solution. Similar wavy-wrinkling surface structures were observed in almost all specimens, when treated either with 0.3% benzalkonium chloride solution or ozone. Conclusion The SEM images obtained from this study revealed that both immersion disinfectants and ozone show similar impression material surface alterations. Ozone seems to be non-inferior as compared to immersion disinfectants, but superior as to environmental protection. PMID:28208993

  14. Initial Tensile and Residual Forces of Pigmented Elastomeric Ligatures from Various Brands

    Science.gov (United States)

    Wichai, Wassana; Anuwongnukroh, Niwat; Dechkunakorn, Surachai; Kaypetch, Rattiporn; Tua-ngam, Peerapong

    2017-11-01

    This study aimed to investigate the initial tensile and residual forces of pigmented elastomeric ligatures (clear, pink, and metallic) from three commercial brands - Brand 1 (USA), Brand 2 (USA), and Brand 3(China). Twelve elastomeric ligatures of each brand and color were evaluated for initial tensile and residual forces after stretching for 28 days at 37°C by a Universal Testing Machine. The results showed that the highest initial tensile force was 14.78 N, 20.71 N, and 15.1 N for the metallic color of Brand-1, pink color of Brand -2, and metallic color of Brand -3, respectively. There were significant (ptensile force of each brand, except clear and metallic color of Brand-1 & 3 and pink color of Brand-2 & 3. Similarly, among the pigmented ligatures from each brand, significant (ptensile force, except metallic color of Brand-1 & 3. Brand-3 had the highest residual force after 28 days, whereas the loss of force was 80-90% in Brand-1 & 2 and 20-30% in Brand-3. There were also significant (ptensile and residual forces among the three pigmented elastomeric ligatures of the three commercial brands.

  15. Forces released during alignment with a preadjusted appliance with different types of elastomeric ligatures.

    Science.gov (United States)

    Franchi, Lorenzo; Baccetti, Tiziano

    2006-05-01

    The purpose of this in-vitro study was to compare the forces generated by new nonconventional elastomeric ligatures (NCEL) and conventional elastomeric ligatures (CEL) during leveling and aligning phases. The testing model consisted of 5 stainless steel 0.022-in preadjusted brackets for second premolar, first premolar, canine, lateral incisor, and central incisor. The canine bracket was welded to a sliding bar that allowed for different vertical positions. The forces generated by 3 sizes of wires (0.012-, 0.014-, and 0.016-in superelastic nickel-titanium) with the 2 types of elastomeric ligatures at different amounts of upward canine misalignment (1.5, 3, 4.5, and 6 mm) were recorded. Significant differences between CEL and NCEL were found for all tested variables (P <.01) with the exception of the 0.014- and 0.016-in wires at canine misalignment of 1.5 mm. A noticeable amount of force was generated with the NCEL at all 4 canine positions with all 3 wire sizes (from about 50 to about 150 g). With 4.5 mm of canine misalignment or more, the average amount of released force with the CEL was approximately zero.

  16. Investigation of the recycling of tires to elastomeric requirements by techniques of thermal compression

    Science.gov (United States)

    Nadal Gisbert, Antonio V.

    In this work is investigated the recycling of tires to elastomeric requirements by thermal compression. The production of recycled products is carried out starting from the powder, of elastomeric nature, coming from the grinding of used tires denominated GTR (Ground Tire Rubber) of different grain size, although the fundamental objective is the recycling of powder of 0,2mm grain size. The process of forming used for obtaining the recycled product is thermal compression, due to its simplicity and low cost. The composition of the powder has been analyzed and also the influence, on the elastomeric characteristics of the recycled product, of different parameters: Grain size, compact pressure, temperature, time, thickness of the recycled product and combination of sizes. At last we give an hypothesis that justifies the mechanism that gives cohesion to the powder GTR and allows their recycling. We also have carried out an analysis of the investigation lines, at the present, on the recycling of tires in general and an economic study of the viability of the recycled product in front of present products in the market, agglomerated with polyurethane, that have their application in using it in different types of floors.

  17. Smart thermal patch for adaptive thermotherapy

    KAUST Repository

    Hussain, Muhammad Mustafa

    2015-11-12

    A smart thermal patch for adaptive thermotherapy is provided. In an embodiment, the patch can be a stretchable, non-polymeric, conductive thin film flexible and non-invasive body integrated mobile thermal heater with wireless control capabilities that can be used to provide adaptive thermotherapy. The patch can be geometrically and spatially tunable on various pain locations. Adaptability allows the amount of heating to be tuned based on the temperature of the treated portion.

  18. Patch layout generation by detecting feature networks

    KAUST Repository

    Cao, Yuanhao

    2015-02-01

    The patch layout of 3D surfaces reveals the high-level geometric and topological structures. In this paper, we study the patch layout computation by detecting and enclosing feature loops on surfaces. We present a hybrid framework which combines several key ingredients, including feature detection, feature filtering, feature curve extension, patch subdivision and boundary smoothing. Our framework is able to compute patch layouts through concave features as previous approaches, but also able to generate nice layouts through smoothing regions. We demonstrate the effectiveness of our framework by comparing with the state-of-the-art methods.

  19. Collection of analytes from microneedle patches.

    Science.gov (United States)

    Romanyuk, Andrey V; Zvezdin, Vasiliy N; Samant, Pradnya; Grenader, Mark I; Zemlyanova, Marina; Prausnitz, Mark R

    2014-11-04

    Clinical medicine and public health would benefit from simplified acquisition of biological samples from patients that can be easily obtained at point of care, in the field, and by patients themselves. Microneedle patches are designed to serve this need by collecting dermal interstitial fluid containing biomarkers without the dangers, pain, or expertise needed to collect blood. This study presents novel methods to collect biomarker analytes from microneedle patches for analysis by integration into conventional analytical laboratory microtubes and microplates. Microneedle patches were made out of cross-linked hydrogel composed of poly(methyl vinyl ether-alt-maleic acid) and poly(ethylene glycol) prepared by micromolding. Microneedle patches were shown to swell with water up to 50-fold in volume, depending on degree of polymer cross-linking, and to collect interstitial fluid from the skin of rats. To collect analytes from microneedle patches, the patches were mounted within the cap of microcentrifuge tubes or formed the top of V-bottom multiwell microplates, and fluid was collected in the bottom of the tubes under gentle centrifugation. In another method, microneedle patches were attached to form the bottom of multiwell microplates, thereby enabling in situ analysis. The simplicity of biological sample acquisition using microneedle patches coupled with the simplicity of analyte collection from microneedles patches integrated into conventional analytical equipment could broaden the reach of future screening, diagnosis, and monitoring of biomarkers in healthcare and environmental/workplace settings.

  20. PATIENTS' KNOWLEDGE OF MEDICAL PATCHES IN HUNGARY.

    Science.gov (United States)

    Somogyi, Orsolya; Zelko, Romana

    2016-11-01

    Transdermal therapy with medical patches is a simple possibility in home medication. As the correct use of patches has a decisive impact from the point of its modulator effect.A questionnaire survey was developed to explore level of patients' knowledge of the correct use of transdermal patches. A survey was administered in thirteen Hungarian community pharmacies from October of 2012 to May of 2015. Most of the participants, men and women over 18 years of age (n = 233), used major analgesic patches (fentanyl); the remainder were given nitroglycerin, NSAID analgesics patches during the survey. For the hypothesis testing it was assumed that men were more likely to use a razor for skin depilation before patch application than women as their denser pelage hinders patch adhesion. The hypothesis testing showed no significant gender difference in razor use (X² = 0.201; p = 0.654). Pharmacists should direct patients to avoid using soap for skin cleansing before patch application because only 22 percent of the participants always avoided its use. Since only 9 tests were flawless from 233 completed questionnaires. Many patients do not understand how to correctly apply a transdermal dosage patch. Pharmacists should teach their correct application based on results.

  1. An Evaluation of the Effect of Various Gloves on Polymerization Inhibition of Elastomeric Impression Materials: An In vitro Study.

    Science.gov (United States)

    Hiremath, Vinuta; Vinayakumar, G; Ragher, Mallikarjuna; Rayannavar, Sounyala; Bembalagi, Mahantesh; Ashwini, B L

    2017-11-01

    Latex protective barriers such as gloves and rubber dam material have been used widely in restorative procedures for crown and bridge. However, the chemical used during latex glove fabrication is thought to inhibit the polymerization of elastomeric impression materials used for impression making which has a detrimental effect on the dimensional accuracy and surface definition of resultant casts used for restorative procedures. The objectives of the study were to examine the surface of different elastomeric impressions on contact with various gloves. This clinical study included a total of eighty specimens of two types of the putty elastomeric impression material were hand manipulated by wearing three different gloves materials and is placed on a marked area of a clean and alcohol-treated glass slab at room temperature. The specimens examined for any signs of polymerization inhibition. The specimen will be rated as being "inhibited" if any residue remains on the glass slab and absence of the above will result as "no inhibition." The results showed no interference with the polymerization inhibition of the selected elastomers followed by the nitrile glove. The latex gloves showed inhibited set of the elastomeric impression material but set after sometime confirming time-dependent inhibition of the impression material. This study shows that the use of latex and sometime nitrile gloves during crown and bridge procedures should be contraindicated and the use of vinyl gloves should be stressed when working with elastomeric impression materials.

  2. An evaluation of the effect of various gloves on polymerization inhibition of elastomeric impression materials: An In vitro study

    Directory of Open Access Journals (Sweden)

    Vinuta Hiremath

    2017-01-01

    Full Text Available Background: Latex protective barriers such as gloves and rubber dam material have been used widely in restorative procedures for crown and bridge. However, the chemical used during latex glove fabrication is thought to inhibit the polymerization of elastomeric impression materials used for impression making which has a detrimental effect on the dimensional accuracy and surface definition of resultant casts used for restorative procedures. The objectives of the study were to examine the surface of different elastomeric impressions on contact with various gloves. Materials and Methods: This clinical study included a total of eighty specimens of two types of the putty elastomeric impression material were hand manipulated by wearing three different gloves materials and is placed on a marked area of a clean and alcohol-treated glass slab at room temperature. The specimens examined for any signs of polymerization inhibition. The specimen will be rated as being “inhibited” if any residue remains on the glass slab and absence of the above will result as “no inhibition.” Results: The results showed no interference with the polymerization inhibition of the selected elastomers followed by the nitrile glove. The latex gloves showed inhibited set of the elastomeric impression material but set after sometime confirming time-dependent inhibition of the impression material. Conclusion: This study shows that the use of latex and sometime nitrile gloves during crown and bridge procedures should be contraindicated and the use of vinyl gloves should be stressed when working with elastomeric impression materials.

  3. Towards development of lignin reinforced elastomeric compounds with reduced energy dissipation

    Science.gov (United States)

    Bahl, Kushal

    This research deals with development of lignin as reinforcing filler for elastomeric compounds. Lignins are naturally abundant and cost competitive wood derivatives possessing strong mechanical properties and offering reactive functional groups on their surfaces. The presence of the functional groups imparts polarity to the lignin molecules and makes them incompatible with non-polar elastomers. Also, the large particle size of lignin does not produce desired mechanical reinforcement. The present study deals with solving the outstanding issues associated with the use of lignin as fillers for polymeric compounds. In addition, the work specifically focuses on producing rubber compounds with reduced energy dissipation via partial replacement of carbon black with lignin. The first part of this study is devoted to suppression of the polarity of lignin and achievement of compatibility with rubber matrix via modification of lignosulfonates (LS) with cyclohexylamine (CA). CA reduces the polarity of lignin via interactions originating from proton transfer and hydrogen bonding. X-ray Photoelectron Spectroscopy (XPS) confirms the attachment of CA on the surfaces of lignin. The mechanical properties of rubber compounds increase substantially along with improvement in cure properties and increase in crosslink density in the presence of LS particles modified with CA. The tensile strength and storage modulus show an increase by 45% and 41% respectively. The values of the 100% modulus and elongation at break also improve by 35% and 60% respectively. The second part of this study exploits the non-covalent interactions between lignin and carbon black (CB) for the design of novel hybrid filler particles exhibiting lower energy loss in rubber compounds. The hybrid fillers offer unique morphology consisting of coating layers of lignin on carbon black particle aggregates. It is found that such coating layers are formed due to pi-pi interactions between lignin and carbon black. Raman

  4. Transdermal patches: history, development and pharmacology

    Science.gov (United States)

    Pastore, Michael N; Kalia, Yogeshvar N; Horstmann, Michael; Roberts, Michael S

    2015-01-01

    Transdermal patches are now widely used as cosmetic, topical and transdermal delivery systems. These patches represent a key outcome from the growth in skin science, technology and expertise developed through trial and error, clinical observation and evidence-based studies that date back to the first existing human records. This review begins with the earliest topical therapies and traces topical delivery to the present-day transdermal patches, describing along the way the initial trials, devices and drug delivery systems that underpin current transdermal patches and their actives. This is followed by consideration of the evolution in the various patch designs and their limitations as well as requirements for actives to be used for transdermal delivery. The properties of and issues associated with the use of currently marketed products, such as variability, safety and regulatory aspects, are then described. The review concludes by examining future prospects for transdermal patches and drug delivery systems, such as the combination of active delivery systems with patches, minimally invasive microneedle patches and cutaneous solutions, including metered-dose systems. PMID:25560046

  5. Formaldehyde concentration in diagnostic patch testing

    DEFF Research Database (Denmark)

    Trattner, A; Johansen, J D; Menné, T

    1998-01-01

    Exposure to formaldehyde is common from both consumer products and industry. The reliability of the patch test is essential for the diagnosis of formaldehyde allergy as it is difficult to suspect from the patient's history. The recommended formaldehyde patch test concentration has been reduced over...

  6. Immunoisolation Patch System for Cellular Transplantation

    Science.gov (United States)

    Wang, Taylor G. (Inventor)

    2014-01-01

    An immunoisolation patch system, and particularly a patch system comprising multiple immunoisolation microcapsules, each encapsulating biological material such as cells for transplantation, which can be used in the prophylactic and therapeutic treatment of disease in large animals and humans without the need for immunosuppression.

  7. Image quality assessment based on inter-patch and intra-patch similarity.

    Directory of Open Access Journals (Sweden)

    Fei Zhou

    Full Text Available In this paper, we propose a full-reference (FR image quality assessment (IQA scheme, which evaluates image fidelity from two aspects: the inter-patch similarity and the intra-patch similarity. The scheme is performed in a patch-wise fashion so that a quality map can be obtained. On one hand, we investigate the disparity between one image patch and its adjacent ones. This disparity is visually described by an inter-patch feature, where the hybrid effect of luminance masking and contrast masking is taken into account. The inter-patch similarity is further measured by modifying the normalized correlation coefficient (NCC. On the other hand, we also attach importance to the impact of image contents within one patch on the IQA problem. For the intra-patch feature, we consider image curvature as an important complement of image gradient. According to local image contents, the intra-patch similarity is measured by adaptively comparing image curvature and gradient. Besides, a nonlinear integration of the inter-patch and intra-patch similarity is presented to obtain an overall score of image quality. The experiments conducted on six publicly available image databases show that our scheme achieves better performance in comparison with several state-of-the-art schemes.

  8. Multiple refraction switches realized by stretching elastomeric scatterers in sonic crystals

    Directory of Open Access Journals (Sweden)

    Y. Huang

    2015-02-01

    Full Text Available The effect of out-of-plane pre-stretch on the 2D sonic crystal with stretchable elastomeric scatterers is explored. The hyperelastic scatterers are characterized by a compressible neo-Hookean model. The Dirichlet-to-Neumann (DtN map is adopted to obtain the band structure and equi-frequency contours. We focus on the first passband and find that a variety of switching functionalities for refraction behaviors can be realized in selected frequencies under a specific pre-stretch range. These refraction switches enable an active control of wave propagation and are applicable in advanced technologies where switchable and multifunctional sonic crystals are required.

  9. Optical Manipulation of Shape-Morphing Elastomeric Liquid Crystal Microparticles Doped with Gold Nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Y. R.; Evans, J. S.; Lee, T.; Senyuk, B.; Keller, P.; He, S. L.; Smalyukh, I. I.

    2012-06-11

    We demonstrate facile optical manipulation of shape of birefringent colloidal microparticles made from liquid crystal elastomers. Using soft lithography and polymerization, we fabricate elastomeric microcylinders with weakly undulating director oriented on average along their long axes. These particles are infiltrated with gold nanospheres acting as heat transducers that allow for an efficient localized transfer of heat from a focused infrared laser beam to a submicrometer region within a microparticle. Photothermal control of ordering in the liquid crystal elastomer using scanned beams allows for a robust control of colloidal particles, enabling both reversible and irreversible changes of shape. Possible applications include optomechanics, microfluidics, and reconfigurable colloidal composites with shape-dependent self-assembly.

  10. Elastomeric thermal interface materials with high through-plane thermal conductivity from carbon fiber fillers vertically aligned by electrostatic flocking.

    Science.gov (United States)

    Uetani, Kojiro; Ata, Seisuke; Tomonoh, Shigeki; Yamada, Takeo; Yumura, Motoo; Hata, Kenji

    2014-09-03

    Electrostatic flocking is applied to create an array of aligned carbon fibers from which an elastomeric thermal interface material (TIM) can be fabricated with a high through-plane thermal conductivity of 23.3 W/mK. A high thermal conductivity can be achieved with a significantly low filler level (13.2 wt%). As a result, this material retains the intrinsic properties of the matrix, i.e., elastomeric behavior. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. New injectable elastomeric biomaterials for hernia repair and their biocompatibility.

    Science.gov (United States)

    Skrobot, J; Zair, L; Ostrowski, M; El Fray, M

    2016-01-01

    Complications associated with implantation of polymeric hernia meshes remain a difficult surgical challenge. We report here on our work, developing for the first time, an injectable viscous material that can be converted to a solid and elastic implant in vivo, thus successfully closing herniated tissue. In this study, long-chain fatty acids were used for the preparation of telechelic macromonomers end-capped with methacrylic functionalities to provide UV curable systems possessing high biocompatibility, good mechanical strength and flexibility. Two different systems, comprising urethane and ester bonds, were synthesized from non-toxic raw materials and then subjected to UV curing after injection of viscous material into the cavity at the abdominal wall during hernioplasty in a rabbit hernia model. No additional fixation or sutures were required. The control group of animals was treated with commercially available polypropylene hernia mesh. The observation period lasted for 28 days. We show here that artificially fabricated defect was healed and no reherniation was observed in the case of the fatty acid derived materials. Importantly, the number of inflammatory cells found in the surrounding tissue was comparable to these found around the standard polypropylene mesh. No inflammatory cells were detected in connective tissues and no sign of necrosis has been observed. Collectively, our results demonstrated that new injectable and photocurable systems can be used for minimally invasive surgical protocols in repair of small hernia defects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Mathematics in a Pumpkin Patch.

    Science.gov (United States)

    Taffe, William J.

    1978-01-01

    Estimating the weight of large pumpkins before harvest presents an opportunity for applying several diverse mathematical topics. A model that allows an estimation by easy tape measurement is derived. (MP)

  13. A constrained maximization formulation to analyze deformation of fiber reinforced elastomeric actuators

    Science.gov (United States)

    Singh, Gaurav; Krishnan, Girish

    2017-06-01

    Fiber reinforced elastomeric enclosures (FREEs) are soft and smart pneumatic actuators that deform in a predetermined fashion upon inflation. This paper analyzes the deformation behavior of FREEs by formulating a simple calculus of variations problem that involves constrained maximization of the enclosed volume. The model accurately captures the deformed shape for FREEs with any general fiber angle orientation, and its relation with actuation pressure, material properties and applied load. First, the accuracy of the model is verified with existing literature and experiments for the popular McKibben pneumatic artificial muscle actuator with two equal and opposite families of helically wrapped fibers. Then, the model is used to predict and experimentally validate the deformation behavior of novel rotating-contracting FREEs, for which no prior literature exist. The generality of the model enables conceptualization of novel FREEs whose fiber orientations vary arbitrarily along the geometry. Furthermore, the model is deemed to be useful in the design synthesis of fiber reinforced elastomeric actuators for general axisymmetric desired motion and output force requirement.

  14. Sulcus reproduction with elastomeric impression materials: a new in vitro testing method.

    Science.gov (United States)

    Finger, Werner J; Kurokawa, Rie; Takahashi, Hidekazu; Komatsu, Masashi

    2008-12-01

    Aim of this study was to investigate the depth reproduction of differently wide sulci with elastomeric impression materials by single- and double-mix techniques using a tooth and sulcus model, simulating clinical conditions. Impressions with one vinyl polysiloxane (VPS; FLE), two polyethers (PE; IMP and P2), and one hybrid VPS/PE elastomer (FUS) were taken from a truncated steel cone with a circumferential 2 mm deep sulcus, 50, 100 or 200 microm wide. The "root surface" was in steel and the "periodontal tissue" in reversible hydrocolloid. Single-mix impressions were taken with light-body (L) or monophase (M) pastes, double-mix impressions with L as syringe and M or heavy-body (H) as tray materials (n=8). Sulcus reproduction was determined by 3D laser topography of impressions at eight locations, 45 degrees apart. Statistical data analysis by ANOVA and multiple comparison tests (pimpression materials only: FLE=IMP>FUS=P2. At 50 and 100 microm width, significant differences were found between materials (IMP>FUS=FLE>P2) and techniques (L+H=L+M>M>L). The sulcus model is considered useful for screening evaluation of elastomeric impression materials ability to reproduce narrow sulci. All tested materials and techniques reproduced 200 microm wide sulci to almost nominal depth. Irrespective of the impression technique used, IMP showed the best penetration ability in 50 and 100 microm sulci. Double-mix techniques are more suitable to reproduce narrow sulci than single-mix techniques.

  15. Power turbine dynamics - An evaluation of a shear-mounted elastomeric damper

    Science.gov (United States)

    Zorzi, E. S.; Walton, J.; Cunningham, R.

    1983-01-01

    As an alternative to the more conventional squeeze-film bearing damper designs, a Viton-70 shear-mounted, elastomeric damper was built and tested in a T-55 power turbine high-speed balancing rig. This application demonstrated, for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear-mounted damper design was selected because of its compatibility with actual gas turbine engine radial space constraints, its accommodation of both the radial and axial thrust loads present in gas turbine engines, and its capability of controlled axial preload. Test results showed that the Viton-70 elastomeric damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing to the maximum rotor speed of 1676 rad/s (16,000 rpm). Excellent correlation between the predicted and experienced critical speeds, mode shapes, and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

  16. Experiment-Based Sensitivity Analysis of Scaled Carbon-Fiber-Reinforced Elastomeric Isolators in Bonded Applications

    Directory of Open Access Journals (Sweden)

    Farshad Hedayati Dezfuli

    2016-01-01

    Full Text Available Fiber-reinforced elastomeric isolators (FREIs are a new type of elastomeric base isolation systems. Producing FREIs in the form of long laminated pads and cutting them to the required size significantly reduces the time and cost of the manufacturing process. Due to the lack of adequate information on the performance of FREIs in bonded applications, the goal of this study is to assess the performance sensitivity of 1/4-scale carbon-FREIs based on the experimental tests. The scaled carbon-FREIs are manufactured using a fast cold-vulcanization process. The effect of several factors including the vertical pressure, the lateral cyclic rate, the number of rubber layers, and the thickness of carbon fiber-reinforced layers are explored on the cyclic behavior of rubber bearings. Results show that the effect of vertical pressure on the lateral response of base isolators is negligible. However, decreasing the cyclic loading rate increases the lateral flexibility and the damping capacity. Additionally, carbon fiber-reinforced layers can be considered as a minor source of energy dissipation.

  17. A new UV-curing elastomeric substrate for rapid prototyping of microfluidic devices

    Science.gov (United States)

    Alvankarian, Jafar; Yeop Majlis, Burhanuddin

    2012-03-01

    Rapid prototyping in the design cycle of new microfluidic devices is very important for shortening time-to-market. Researchers are facing the challenge to explore new and suitable substrates with simple and efficient microfabrication techniques. In this paper, we introduce and characterize a UV-curing elastomeric polyurethane methacrylate (PUMA) for rapid prototyping of microfluidic devices. The swelling and solubility of PUMA in different chemicals is determined. Time-dependent measurements of water contact angle show that the native PUMA is hydrophilic without surface treatment. The current monitoring method is used for measurement of the electroosmotic flow mobility in the microchannels made from PUMA. The optical, physical, thermal and mechanical properties of PUMA are evaluated. The UV-lithography and molding process is used for making micropillars and deep channel microfluidic structures integrated to the supporting base layer. Spin coating is characterized for producing different layer thicknesses of PUMA resin. A device is fabricated and tested for examining the strength of different bonding techniques such as conformal, corona treating and semi-curing of two PUMA layers in microfluidic application and the results show that the bonding strengths are comparable to that of PDMS. We also report fabrication and testing of a three-layer multi inlet/outlet microfluidic device including a very effective fluidic interconnect for application demonstration of PUMA as a promising new substrate. A simple micro-device is developed and employed for observing the pressure deflection of membrane made from PUMA as a very effective elastomeric valve in microfluidic devices.

  18. Frictional resistance of orthodontic wires tied with 3 types of elastomeric ligatures

    Directory of Open Access Journals (Sweden)

    Amanda Carneiro da Cunha

    2011-12-01

    Full Text Available The aims of this study were to determine and compare frictional resistance obtained by low-friction and conventional elastomeric ligatures in the presence of artificial saliva, and observe whether this variable changed after 21 days. Super Slick® low-friction elastomeric ligatures and conventional ligatures of the brands TP conventional® and Unitek® were placed on standard edgewise maxillary central incisor metal brackets, slot .022" × .028" tying rectangular orthodontic wires .018" × .025". Three experimental groups were arranged according to the type of ligature and a control group in which no wires were used. The friction values obtained between the bracket/wire/ligature set were measured using a Universal Test Machine at a speed of 20 mm/minute, at two experimental time intervals: T0 - immediately after specimen fabrication; and T1 - 21 days after fabrication and immersion in artificial saliva at 37 ºC. Conventional Unitek ligatures and the low-friction ligature (Super Slick showed the lowest friction values at T0. After 21 days (T1, however, conventional Unitek ligatures presented the lowest value. All groups assessed from T0 to T1 showed a numerical reduction in friction values, suggesting that time, heat and humidity may cause elastic degradation, however this was not verified statistically (P > 0.05.

  19. A multiresolution remeshed particle vortex method using patches

    DEFF Research Database (Denmark)

    Rasmussen, Johannes Tophøj; Cottet, George-Henri; Walther, Jens Honore

    vortex particle-mesh VIC algorithm interpolates particle vorticity to a mesh, solves a Poisson equation for the stream function using FFTs and calculates velocities as the curl of the stream function. With both vorticity and velocity available on the mesh, values of the substantial derivative of particle...... implementation with patches of varying resolution, is applied to the two-dimensional flow past a cylinder. The vorticity field can be divided into two regions, an arbitrary patch of vorticity and the remaining exterior vorticity field. Due to the linearity of the Poisson equation the velocity field corresponding...... to the total vorticity field is the sum of the free space solutions to the Poisson equation to each region. Hereby the flow on the patch can be simulated at a higher resolution, while including the influence from the coarser exterior region. Particles are remeshed and interpolated only to the region from which...

  20. METHOD FOR PROVIDING SHAPED BIODEGRADABLE AND ELASTOMERIC STRUCTURES OF (CO) POLYMERS OF 1,3-TRIMETHYLENE CARBONATE (TMC), SHAPED BIODEGRADABLE AND ELASTOMERIC STRUCTURES, AND THE USE OF THESE STRUCTURES

    NARCIS (Netherlands)

    Grijpma, D.W.; Pêgo, A.P.; Feijen, Jan

    2004-01-01

    The present invention relates to methods for providing shaped biodegradable and elastomeric structures of (co)polymers of 1,3­trimethylene carbonate (TMC) with improved (mechanical) properties which can be used for tissue or tissue component support, generation or regeneration. Such shaped

  1. Smooth surfaces from rational bilinear patches

    KAUST Repository

    Shi, Ling; Wang, Jun; Pottmann, Helmut

    2014-01-01

    Smooth freeform skins from simple panels constitute a challenging topic arising in contemporary architecture. We contribute to this problem area by showing how to approximate a negatively curved surface by smoothly joined rational bilinear patches

  2. Biomimetic elastomeric, conductive and biodegradable polycitrate-based nanocomposites for guiding myogenic differentiation and skeletal muscle regeneration.

    Science.gov (United States)

    Du, Yuzhang; Ge, Juan; Li, Yannan; Ma, Peter X; Lei, Bo

    2018-03-01

    Artificial muscle-like biomaterials have gained tremendous interests owing to their broad applications in regenerative medicine, wearable devices, bioelectronics and artificial intelligence. Unfortunately, key challenges are still existed for current materials, including biomimetic viscoelasticity, biocompatibility and biodegradation, multifunctionality. Herein, for the first time, we develop highly elastomeric, conductive and biodegradable poly (citric acid-octanediol-polyethylene glycol)(PCE)-graphene (PCEG) nanocomposites, and demonstrate their applications in myogenic differentiation and guiding skeletal muscle tissue regeneration. In PCEG nanocomposites, PCE provides the biomimetic elastomeric behavior, and the addition of reduced graphene oxide (RGO) endows the enhanced mechanical strength and conductivity. The highly elastomeric behavior, significantly enhanced modulus (400%-800%), strength (200%-300%) of PCEG nanocomposites with controlled biodegradability and electrochemical conductivity were achieved. The myoblasts proliferation and myogenic differentiation were significantly improved by PCEG nanocomposite. Significantly high in vivo biocompatibility of PCEG nanocomposites was observed when implanted in the subcutaneous tissue for 4 weeks in rats. PCEG nanocomposites could significantly enhance the muscle fibers and blood vessels formation in vivo in a skeletal muscle lesion model of rat. This study may provide a novel strategy to develop multifunctional elastomeric nanocomposites with high biocompatibility for potential soft tissue regeneration and stretchable bioelectronic devices. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Glass interface effect on high-strain-rate tensile response of a soft polyurethane elastomeric polymer material

    NARCIS (Netherlands)

    Fan, J.T.; Weerheijm, J.; Sluys, L.J.

    2015-01-01

    The glass interface effect on dynamic tensile response of a soft polyurethane elastomeric polymer material has been investigated by subjecting a glass-polymer system of this polymer material matrix embedded a single 3 mm-diameter glass particle to impact loading in a split Hopkinson tension bar

  4. Fabrication, characterization, and biocompatibility assessment of a novel elastomeric nanofibrous scaffold: A potential scaffold for soft tissue engineering

    DEFF Research Database (Denmark)

    Shamirzaei Jeshvaghani, Elham; Ghasemi-Mobarakeh, Laleh; Mansurnezhad, Reza

    2017-01-01

    With regard to flexibility and strength properties requirements of soft biological tissue, elastomeric materials could be more beneficial in soft tissue engineering applications. The present work investigates the use of an elastic polymer, (polycaprolactone fumarate [PCLF]), for fabricating...... experiments and its application for engineering of soft tissues subjected to in vivo cyclic mechanical stresses....

  5. Analyzing the Safeguarding Our Communities Act: Patch for Patch Return Policy in Ontario

    Directory of Open Access Journals (Sweden)

    Soo-Min Kim

    2018-04-01

    Full Text Available Fentanyl is prescribed to patients suffering from severe chronic pain. Transdermal patches are the best mode of delivery for patients who have developed tolerance for opioids. However, used patches still contain fentanyl that can be extracted and misused, with potentially severe consequences. To address this issue, patients who are prescribed fentanyl patches in Ontario are now required to return previously dispensed patches to receive new patches under the Safeguarding Our Communities Act: Patch for Patch (P4P Return Policy. The problem is significant in Ontario because the province has the largest annual dispense rate of high-dose prescription fentanyl (112 units per 1,000 population in Canada even though the prevalence rate of chronic pain is lower than the national reported range (16.6% in Ontario versus 19.6 to 21.9% in other provinces, according to Gomes et al. 2014. The primary goal of this reform is to instill responsible use of fentanyl patches, and to improve safety for patients and the public by having a central disposal process. The reform was modeled after a community initiative that was pioneered in North Bay after receiving great support from health professional colleges and communities that voluntarily integrated the program prior to the introduction of Bill 33. Preliminary data suggest that the P4P policy is positively received by health professionals, although ongoing evaluation is needed to assess the effectiveness of the policy in reducing misuse and abuse of prescribed fentanyl patches.

  6. Effect of commonly used beverage, soft drink, and mouthwash on force delivered by elastomeric chain: a comparative in vitro study.

    Science.gov (United States)

    Kumar, Kiran; Shetty, Sharath; Krithika, M J; Cyriac, Bobby

    2014-06-01

    The objective was to evaluate and compare the effect of Coca-Cola®, tea, Listerine® mouthwash on the force delivered by elastomeric chain in vitro. Four specimen groups (distilled water, Coca-Cola®, tea, Listerine® mouthwash) with a total sample size of 480 specimens. A specimen is described as a four link grey close elastomeric chain. Jigs, each with a series of pins set 25 mm apart, was used to hold stretched elastomeric chains at a constant length. These jigs allowed for complete submersion of the elastomeric chain in a water bath throughout the test period, as well as the dipping of elastomeric chains in respective control and test solutions. For 60 s, twice a day, groups were exposed to the respective solutions, the two daily exposure was separated by 9 h and force measurements were taken at six time points during the experiment, that is, 1 h, 24 h, 7 days, 14 days, 21 days, and 28 days. Force measurements were made by Instron machine by a single blinded examiner with the help of a second examiner. It was found out that there was highly significant difference between groups control, Coca-Cola®, Listerine®, and tea as well as there was highly significant (p Coca-Cola® and the Listerine® group reached a plateau between 7 and 21 days then decrease between 21 and 28 days. The tea group showed plateau phase between 7 and 28 days. After 28 days in the control group, 25% force decay occurred while the test groups force decay of 30-50% occurred. Coca-Cola®, Listerine® mouthwash, and tea cause an increase in force decay of elastomeric chains over time. Tea caused highest force decay followed by Listerine® and Coca-Cola® when compared to control group. How to cite the article: Kumar K, Shetty S, Krithika MJ, Cyriac B. Effect of commonly used beverage, soft drink, and mouthwash on force delivered by elastomeric chain: A comparative in vitro study. J Int Oral Health 2014;6(3):7-10.

  7. Molecular modeling of the elastomeric properties of repeating units and building blocks of resilin, a disordered elastic protein.

    Science.gov (United States)

    Khandaker, Md Shahriar K; Dudek, Daniel M; Beers, Eric P; Dillard, David A; Bevan, David R

    2016-08-01

    The mechanisms responsible for the properties of disordered elastomeric proteins are not well known. To better understand the relationship between elastomeric behavior and amino acid sequence, we investigated resilin, a disordered rubber-like protein, found in specialized regions of the cuticle of insects. Resilin of Drosophila melanogaster contains Gly-rich repetitive motifs comprised of the amino acids, PSSSYGAPGGGNGGR, which confer elastic properties to resilin. The repetitive motifs of insect resilin can be divided into smaller partially conserved building blocks: PSS, SYGAP, GGGN and GGR. Using molecular dynamics (MD) simulations, we studied the relative roles of SYGAP, and its less common variants SYSAP and TYGAP, on the elastomeric properties of resilin. Results showed that SYGAP adopts a bent structure that is one-half to one-third the end-to-end length of the other motifs having an equal number of amino acids but containing SYSAP or TYGAP substituted for SYGAP. The bent structure of SYGAP forms due to conformational freedom of glycine, and hydrogen bonding within the motif apparently plays a role in maintaining this conformation. These structural features of SYGAP result in higher extensibility compared to other motifs, which may contribute to elastic properties at the macroscopic level. Overall, the results are consistent with a role for the SYGAP building block in the elastomeric properties of these disordered proteins. What we learned from simulating the repetitive motifs of resilin may be applicable to the biology and mechanics of other elastomeric biomaterials, and may provide us the deeper understanding of their unique properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Coevolution of patch-type dependent emigration and patch-type dependent immigration.

    Science.gov (United States)

    Weigang, Helene C

    2017-08-07

    The three phases of dispersal - emigration, transfer and immigration - are affecting each other and the former and latter decisions may depend on patch types. Despite the inevitable fact of the complexity of the dispersal process, patch-type dependencies of dispersal decisions modelled as emigration and immigration are usually missing in theoretical dispersal models. Here, I investigate the coevolution of patch-type dependent emigration and patch-type dependent immigration in an extended Hamilton-May model. The dispersing population inhabits a landscape structured into many patches of two types and disperses during a continuous-time season. The trait under consideration is a four dimensional vector consisting of two values for emigration probability from the patches and two values for immigration probability into the patches of each type. Using the adaptive dynamics approach I show that four qualitatively different dispersal strategies may evolve in different parameter regions, including a counterintuitive strategy, where patches of one type are fully dispersed from (emigration probability is one) but individuals nevertheless always immigrate into them during the dispersal season (immigration probability is one). I present examples of evolutionary branching in a wide parameter range, when the patches with high local death rate during the dispersal season guarantee a high expected disperser output. I find that two dispersal strategies can coexist after evolutionary branching: a strategy with full immigration only into the patches with high expected disperser output coexists with a strategy that immigrates into any patch. Stochastic simulations agree with the numerical predictions. Since evolutionary branching is also found when immigration evolves alone, the present study is adding coevolutionary constraints on the emigration traits and hence finds that the coevolution of a higher dimensional trait sometimes hinders evolutionary diversification. Copyright © 2017

  9. Diurnal and seasonal occurrence of polar patches

    Directory of Open Access Journals (Sweden)

    A. S. Rodger

    1996-05-01

    Full Text Available Analysis of the diurnal and seasonal variation of polar patches, as identified in two years of HF-radar data from Halley, Antarctica during a period near sunspot maximum, shows that there is a broad maximum in occurrence centred about magnetic noon, not local noon. There are minima in occurrence near midsummer and midwinter, with maxima in occurrence between equinox and winter. There are no significant correlations between the occurrence of polar patches and the corresponding hourly averages of the solar wind and IMF parameters, except that patches usually occur when the interplanetary magnetic field has a southward component. The results can be understood in terms of UT and seasonal differences in the plasma concentration being convected from the dayside ionosphere into the polar cap. In summer and winter the electron concentrations in the polar cap are high and low, respectively, but relatively unstructured. About equinox, a tongue of enhanced ionisation is convected into the polar cap; this tongue is then structured by the effects of the interplanetary magnetic field, but these Halley data cannot be used to separate the various competing mechanisms for patch formation. The observed diurnal and seasonal variation in the occurrence of polar patches are largely consistent with predictions of Sojka et al. (1994 when their results are translated into the southern hemisphere. However, the ionospheric effects of flux transfer events are still considered essential in their formation, a feature not yet included in the Sojka et al. model.

  10. Microneedle patches for vaccination in developing countries.

    Science.gov (United States)

    Arya, Jaya; Prausnitz, Mark R

    2016-10-28

    Millions of people die of infectious diseases each year, mostly in developing countries, which could largely be prevented by the use of vaccines. While immunization rates have risen since the introduction of the Expanded Program on Immunization (EPI), there remain major challenges to more effective vaccination in developing countries. As a possible solution, microneedle patches containing an array of micron-sized needles on an adhesive backing have been developed to be used for vaccine delivery to the skin. These microneedle patches can be easily and painlessly applied by pressing against the skin and, in some designs, do not leave behind sharps waste. The patches are single-dose, do not require reconstitution, are easy to administer, have reduced size to simplify storage, transportation and waste disposal, and offer the possibility of improved vaccine immunogenicity, dose sparing and thermostability. This review summarizes vaccination challenges in developing countries and discusses advantages that microneedle patches offer for vaccination to address these challenges. We conclude that microneedle patches offer a powerful new technology that can enable more effective vaccination in developing countries. Copyright © 2015. Published by Elsevier B.V.

  11. Mechanics of nanowire/nanotube in-surface buckling on elastomeric substrates

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, J; Huang, Y [Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208 (United States); Ryu, S Y; Paik, U [Division of Materials Science and Engineering, Hanyang University, 17 Hangdang-dong, Sungdong-gu, Seoul 133-791 (Korea, Republic of); Hwang, K-C [Department of Engineering Mechanics, Tsinghua University, Beijing 100084 (China); Rogers, J A, E-mail: y-huang@northwestern.edu, E-mail: jrogers@uiuc.edu [Department of Materials Science and Engineering, Frederick-Seitz Materials Research Laboratory and Beckman Institute, University of Illinois at Urbana-Champaign, Illinois 61801 (United States)

    2010-02-26

    A continuum mechanics theory is established for the in-surface buckling of one-dimensional nanomaterials on compliant substrates, such as silicon nanowires on elastomeric substrates observed in experiments. Simple analytical expressions are obtained for the buckling wavelength, amplitude and critical buckling strain in terms of the bending and tension stiffness of the nanomaterial and the substrate elastic properties. The analysis is applied to silicon nanowires, single-walled carbon nanotubes, multi-walled carbon nanotubes, and carbon nanotube bundles. For silicon nanowires, the measured buckling wavelength gives Young's modulus to be 140 GPa, which agrees well with the prior experimental studies. It is shown that the energy for in-surface buckling is lower than that for normal (out-of-surface) buckling, and is therefore energetically favorable.

  12. Mechanics of nanowire/nanotube in-surface buckling on elastomeric substrates

    International Nuclear Information System (INIS)

    Xiao, J; Huang, Y; Ryu, S Y; Paik, U; Hwang, K-C; Rogers, J A

    2010-01-01

    A continuum mechanics theory is established for the in-surface buckling of one-dimensional nanomaterials on compliant substrates, such as silicon nanowires on elastomeric substrates observed in experiments. Simple analytical expressions are obtained for the buckling wavelength, amplitude and critical buckling strain in terms of the bending and tension stiffness of the nanomaterial and the substrate elastic properties. The analysis is applied to silicon nanowires, single-walled carbon nanotubes, multi-walled carbon nanotubes, and carbon nanotube bundles. For silicon nanowires, the measured buckling wavelength gives Young's modulus to be 140 GPa, which agrees well with the prior experimental studies. It is shown that the energy for in-surface buckling is lower than that for normal (out-of-surface) buckling, and is therefore energetically favorable.

  13. Silicon micro-masonry using elastomeric stamps for three-dimensional microfabrication

    International Nuclear Information System (INIS)

    Keum, Hohyun; Eisenhaure, Jeffrey D; Kim, Seok; Carlson, Andrew; Ning, Hailong; Mihi, Agustin; Braun, Paul V; Rogers, John A

    2012-01-01

    We present a micromanufacturing method for constructing microsystems, which we term ‘micro-masonry’ based on individual manipulation, influenced by strategies for deterministic materials assembly using advanced forms of transfer printing. Analogous to masonry in construction sites, micro-masonry consists of the preparation, manipulation, and binding of microscale units to assemble microcomponents and microsystems. In this paper, for the purpose of demonstration, we used microtipped elastomeric stamps as manipulators and built three dimensional silicon microstructures. Silicon units of varied shapes were fabricated in a suspended format on donors, retrieved, delivered, and placed on a target location on a receiver using microtipped stamps. Annealing of the assembled silicon units permanently bound them and completed the micro-masonry procedure. (paper)

  14. The effect of rinsing time periods on wettability of elastomeric impression materials: in vitro study

    Directory of Open Access Journals (Sweden)

    Özlem Acar

    2016-01-01

    Full Text Available OBJECTIVE: The aim of this study was to determine whether different rinsing time periods affected the wettability of polymerized elastomeric impression materials. MATERIALS AND METHOD: Panasil Contact Plus (PCP, Panasil Contact Non-Surfactant (PCNS, Panasil Initial Contact (PIC, Express (EXP and Impregum (IMP impression materials were tested. Standardized samples were rinsed with water for 10 s, 15 s or 20 s, and the wettability was determined by contact angle measurement through an evaluation period of 60 seconds (n=7. Non-rinsed groups were used as control. Measurements were made at 5 time points (at 0, 6, 15, 30 and 60 seconds. Kruskal Wallis test and Conover’s multiple comparison tests were used for all multiple comparisons. Bonferroni adjustment was applied for controlling Type I error (p0.002. CONCLUSION: Rinsing the surfactant-containing polyvinylsiloxane impression materials decreased their wettability, whereas no such effect was seen for the surfactant free polyvinylsiloxane and polyether impression materials.

  15. Active shape-morphing elastomeric colloids in short-pitch cholesteric liquid crystals.

    Science.gov (United States)

    Evans, Julian S; Sun, Yaoran; Senyuk, Bohdan; Keller, Patrick; Pergamenshchik, Victor M; Lee, Taewoo; Smalyukh, Ivan I

    2013-05-03

    Active elastomeric liquid crystal particles with initial cylindrical shapes are obtained by means of soft lithography and polymerization in a strong magnetic field. Gold nanocrystals infiltrated into these particles mediate energy transfer from laser light to heat, so that the inherent coupling between the temperature-dependent order and shape allows for dynamic morphing of these particles and well-controlled stable shapes. Continuous changes of particle shapes are followed by their spontaneous realignment and transformations of director structures in the surrounding cholesteric host, as well as locomotion in the case of a nonreciprocal shape morphing. These findings bridge the fields of liquid crystal solids and active colloids, may enable shape-controlled self-assembly of adaptive composites and light-driven micromachines, and can be understood by employing simple symmetry considerations along with electrostatic analogies.

  16. Optimization of fractional composition of the excipient in the elastomeric covering for asphalt highways

    Directory of Open Access Journals (Sweden)

    E. M. Nurullaev

    2013-04-01

    Full Text Available The computational method of optimum fractional composition of a dispersible filler of polymeric composite on the basis of three-dimensionally linked elastomer is developed according to non-linear programming. The coefficient of dynamic viscosity of polymeric suspension or the initial module of a viscoelasticity of the join solidification low-molecular rubbers with the final functional groups, filled by many fractional dioxide of silicon are considered as criteria of optimization. Influence of the limiting volume filling on energy of mechanical destruction was investigated. The elastomeric material is offered for use as a covering of asphalt highways in the form of a frost-proof waterproofing layer, which allowing multiply to increase operating properties.

  17. How Do Landscape Structure, Management and Habitat Quality Drive the Colonization of Habitat Patches by the Dryad Butterfly (Lepidoptera: Satyrinae) in Fragmented Grassland?

    Science.gov (United States)

    Kalarus, Konrad; Nowicki, Piotr

    2015-01-01

    Most studies dealing with species distribution patterns on fragmented landscapes focus on the characteristics of habitat patches that influence local occurrence and abundance, but they tend to neglect the question of what drives colonization of previously unoccupied patches. In a study of the dryad butterfly, we combined classical approaches derived from metapopulation theory and landscape ecology to investigate the factors driving colonization from a recent refugium. In three consecutive transect surveys, we recorded the presence and numbers of imagos in 27 patches of xerothermic grassland and 26 patches of wet meadow. Among the predictors affecting the occurrence and abundance of the dryad, we considered environmental variables reflecting (i) habitat patch quality (e.g., goldenrod cover, shrub density, vegetation height); (ii) factors associated with habitat spatial structure (patch size, patch isolation and fragmentation); and (iii) features of patch surroundings (100-m buffers around patches) that potentially pose barriers or provide corridors. Patch colonization by the dryad was strongly limited by the distance from the species refugium in the region; there was a slight positive effect of shrub density in this respect. Butterfly abundance increased in smaller and more fragmented habitat patches; it was negatively impacted by invasive goldenrod cover, and positively influenced by the density of watercourses in patch surroundings. Nectar plant availability was positively related to species abundance in xerothermic grassland, while in wet meadow the effect was the reverse. We conclude that dryad colonization of our study area is very recent, since the most important factor limiting colonization was distance from the refugium, while the habitat quality of target patches had less relevance. In order to preserve the species, conservation managers should focus on enhancing the quality of large patches and should also direct their efforts on smaller and more

  18. How Do Landscape Structure, Management and Habitat Quality Drive the Colonization of Habitat Patches by the Dryad Butterfly (Lepidoptera: Satyrinae in Fragmented Grassland?

    Directory of Open Access Journals (Sweden)

    Konrad Kalarus

    Full Text Available Most studies dealing with species distribution patterns on fragmented landscapes focus on the characteristics of habitat patches that influence local occurrence and abundance, but they tend to neglect the question of what drives colonization of previously unoccupied patches. In a study of the dryad butterfly, we combined classical approaches derived from metapopulation theory and landscape ecology to investigate the factors driving colonization from a recent refugium. In three consecutive transect surveys, we recorded the presence and numbers of imagos in 27 patches of xerothermic grassland and 26 patches of wet meadow. Among the predictors affecting the occurrence and abundance of the dryad, we considered environmental variables reflecting (i habitat patch quality (e.g., goldenrod cover, shrub density, vegetation height; (ii factors associated with habitat spatial structure (patch size, patch isolation and fragmentation; and (iii features of patch surroundings (100-m buffers around patches that potentially pose barriers or provide corridors. Patch colonization by the dryad was strongly limited by the distance from the species refugium in the region; there was a slight positive effect of shrub density in this respect. Butterfly abundance increased in smaller and more fragmented habitat patches; it was negatively impacted by invasive goldenrod cover, and positively influenced by the density of watercourses in patch surroundings. Nectar plant availability was positively related to species abundance in xerothermic grassland, while in wet meadow the effect was the reverse. We conclude that dryad colonization of our study area is very recent, since the most important factor limiting colonization was distance from the refugium, while the habitat quality of target patches had less relevance. In order to preserve the species, conservation managers should focus on enhancing the quality of large patches and should also direct their efforts on smaller and

  19. Fault-patch stress-transfer efficiency in presence of sub-patch geometric complexity

    KAUST Repository

    Zielke, Olaf

    2015-04-01

    It is well known that faults are not planar surfaces. Instead they exhibit self-similar or self-affine properties that span a wide range of spatial (sub-micrometer to tens-of-kilometer). This geometric fault roughness has a distinct impact on amount and distribution of stresses/strains induced in the medium and on other portions of the fault. However, when numerically simulated (for example in multi-cycle EQ rupture simulations or Coulomb failure stress calculations) this roughness is largely ignored: individual fault patches --the incremental elements that build the fault surface in the respective computer models-- are planar and fault roughness at this and lower spatial scales is not considered. As a result, the fault-patch stress-transfer efficiency may be systematically too large in those numerical simulations with respect to the "actual" efficiency level. Here, we investigate the effect of sub-patch geometric complexity on fault-patch stress-transfer efficiency. For that, we sub-divide a fault patch (e.g., 1x1km) into a large number of sub-patches (e.g., 20x20m) and determine amount of induced stresses at selected positions around that patch for different levels and realizations of fault roughness. For each fault roughness level, we compute mean and standard deviation of the induced stresses, enabling us to compute the coefficient of variation. We normalize those values with stresses from the corresponding single (planar) fault patch, providing scaling factors and their variability for stress transfer efficiency. Given a certain fault roughness that is assumed for a fault, this work provides the means to implement the sub-patch fault roughness into investigations based on fault-patch interaction schemes.

  20. Patch-augmented rotator cuff repair: influence of the patch fixation technique on primary biomechanical stability.

    Science.gov (United States)

    Jung, Christian; Spreiter, Gregor; Audigé, Laurent; Ferguson, Stephen J; Flury, Matthias

    2016-05-01

    There is an ongoing debate about the potential of patch augmentation to improve biomechanical stability and healing associated with rotator cuff repair. The biomechanical properties of three different patch-augmented rotator cuff repair techniques were assessed in vitro and compared with a standard repair. Dermal collagen patch augmentation may increase the primary stability and strength of the repaired tendon in vitro, depending on the technique used for patch application. Forty cadaveric sheep shoulders with dissected infraspinatus tendons were randomized into four groups (n = 10/group) for tendon repair using a knotless double-row suture anchor technique. A xenologous dermal extracellular matrix patch was used for augmentation in the three test groups using an "integrated", "cover", or "hybrid" technique. Tendons were preconditioned, cyclically loaded from 10 to 30 N at 1 Hz, and then loaded monotonically to failure. Biomechanical properties and the mode of failure were evaluated. Patch augmentation significantly increased the maximum load at failure by 61 % in the "cover" technique test group (225.8 N) and 51 % in the "hybrid" technique test group (211.4 N) compared with the non-augmented control group (140.2 N) (P ≤ 0.015). For the test group with "integrated" patch augmentation, the load at failure was 28 % lower (101.6 N) compared with the control group (P = 0.043). There was no significant difference in initial and linear stiffness among the four experimental groups. The most common mode of failure was tendon pullout. No anchor dislocation, patch disruption or knot breakage was observed. Additional patch augmentation with a collagen patch influences the biomechanical properties of a rotator cuff repair in a cadaveric sheep model. Primary repair stability can be significantly improved depending on the augmentation technique.

  1. Utilizing stretch-tunable thermochromic elastomeric opal films as novel reversible switchable photonic materials.

    Science.gov (United States)

    Schäfer, Christian G; Lederle, Christina; Zentel, Kristina; Stühn, Bernd; Gallei, Markus

    2014-11-01

    In this work, the preparation of highly thermoresponsive and fully reversible stretch-tunable elastomeric opal films featuring switchable structural colors is reported. Novel particle architectures based on poly(diethylene glycol methylether methacrylate-co-ethyl acrylate) (PDEGMEMA-co-PEA) as shell polymer are synthesized via seeded and stepwise emulsion polymerization protocols. The use of DEGMEMA as comonomer and herein established synthetic strategies leads to monodisperse soft shell particles, which can be directly processed to opal films by using the feasible melt-shear organization technique. Subsequent UV crosslinking strategies open access to mechanically stable and homogeneous elastomeric opal films. The structural colors of the opal films feature mechano- and thermoresponsiveness, which is found to be fully reversible. Optical characterization shows that the combination of both stimuli provokes a photonic bandgap shift of more than 50 nm from 560 nm in the stretched state to 611 nm in the fully swollen state. In addition, versatile colorful patterns onto the colloidal crystal structure are produced by spatial UV-induced crosslinking by using a photomask. This facile approach enables the generation of spatially cross-linked switchable opal films with fascinating optical properties. Herein described strategies for the preparation of PDEGMEMA-containing colloidal architectures, application of the melt-shear ordering technique, and patterned crosslinking of the final opal films open access to novel stimuli-responsive colloidal crystal films, which are expected to be promising materials in the field of security and sensing applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Three-Dimensional Elastomeric Scaffolds Designed with Cardiac-Mimetic Structural and Mechanical Features

    Science.gov (United States)

    Neal, Rebekah A.; Jean, Aurélie; Park, Hyoungshin; Wu, Patrick B.; Hsiao, James; Engelmayr, George C.; Langer, Robert

    2013-01-01

    Tissue-engineered constructs, at the interface of material science, biology, engineering, and medicine, have the capacity to improve outcomes for cardiac patients by providing living cells and degradable biomaterials that can regenerate the native myocardium. With an ultimate goal of both delivering cells and providing mechanical support to the healing heart, we designed three-dimensional (3D) elastomeric scaffolds with (1) stiffnesses and anisotropy mimicking explanted myocardial specimens as predicted by finite-element (FE) modeling, (2) systematically varied combinations of rectangular pore pattern, pore aspect ratio, and strut width, and (3) structural features approaching tissue scale. Based on predicted mechanical properties, three scaffold designs were selected from eight candidates for fabrication from poly(glycerol sebacate) by micromolding from silicon wafers. Large 20×20 mm scaffolds with high aspect ratio features (5:1 strut height:strut width) were reproducibly cast, cured, and demolded at a relatively high throughput. Empirically measured mechanical properties demonstrated that scaffolds were cardiac mimetic and validated FE model predictions. Two-layered scaffolds providing fully interconnected pore networks were fabricated by layer-by-layer assembly. C2C12 myoblasts cultured on one-layered scaffolds exhibited specific patterns of cell elongation and interconnectivity that appeared to be guided by the scaffold pore pattern. Neonatal rat heart cells cultured on two-layered scaffolds for 1 week were contractile, both spontaneously and in response to electrical stimulation, and expressed sarcomeric α-actinin, a cardiac biomarker. This work not only demonstrated several scaffold designs that promoted functional assembly of rat heart cells, but also provided the foundation for further computational and empirical investigations of 3D elastomeric scaffolds for cardiac tissue engineering. PMID:23190320

  3. Boolean Operations with Prism Algebraic Patches

    Science.gov (United States)

    Bajaj, Chandrajit; Paoluzzi, Alberto; Portuesi, Simone; Lei, Na; Zhao, Wenqi

    2009-01-01

    In this paper we discuss a symbolic-numeric algorithm for Boolean operations, closed in the algebra of curved polyhedra whose boundary is triangulated with algebraic patches (A-patches). This approach uses a linear polyhedron as a first approximation of both the arguments and the result. On each triangle of a boundary representation of such linear approximation, a piecewise cubic algebraic interpolant is built, using a C1-continuous prism algebraic patch (prism A-patch) that interpolates the three triangle vertices, with given normal vectors. The boundary representation only stores the vertices of the initial triangulation and their external vertex normals. In order to represent also flat and/or sharp local features, the corresponding normal-per-face and/or normal-per-edge may be also given, respectively. The topology is described by storing, for each curved triangle, the two triples of pointers to incident vertices and to adjacent triangles. For each triangle, a scaffolding prism is built, produced by its extreme vertices and normals, which provides a containment volume for the curved interpolating A-patch. When looking for the result of a regularized Boolean operation, the 0-set of a tri-variate polynomial within each such prism is generated, and intersected with the analogous 0-sets of the other curved polyhedron, when two prisms have non-empty intersection. The intersection curves of the boundaries are traced and used to decompose each boundary into the 3 standard classes of subpatches, denoted in, out and on. While tracing the intersection curves, the locally refined triangulation of intersecting patches is produced, and added to the boundary representation. PMID:21516262

  4. Design of a Composite Membrane with Patches

    International Nuclear Information System (INIS)

    Cuccu, Fabrizio; Emamizadeh, Behrouz; Porru, Giovanni

    2010-01-01

    This paper is concerned with minimization and maximization problems of eigenvalues. The principal eigenvalue of a differential operator is minimized or maximized over a set which is formed by intersecting a rearrangement class with an affine subspace of finite co-dimension. A solution represents an optimal design of a 2-dimensional composite membrane Ω, fixed at the boundary, built out of two different materials, where certain prescribed regions (patches) in Ω are occupied by both materials. We prove existence results, and present some features of optimal solutions. The special case of one patch is treated in detail.

  5. Generic Patch Inference

    DEFF Research Database (Denmark)

    Andersen, Jesper; Lawall, Julia Laetitia

    2008-01-01

    A key issue in maintaining Linux device drivers is the need to update drivers in response to evolutions in Linux internal libraries. Currently, there is little tool support for performing and documenting such changes. In this paper we present a tool, spfind, that identifies common changes made...... developers can use it to extract an abstract representation of the set of changes that others have made. Our experiments on recent changes in Linux show that the inferred generic patches are more concise than the corresponding patches found in commits to the Linux source tree while being safe with respect...

  6. Development and characterization of mucoadhesive buccal patches of salbutamol sulphate.

    Science.gov (United States)

    Patel, Rajesh Singh; Poddar, S S

    2009-01-01

    Mucoadhesive patch releasing the drug in the oral cavity at predetermined rate may present distinct advantages over traditional dosage forms such as tablets, gels and solutions. The present study was concerned with the preparation and evaluation of mucoadhesive buccal patches for the controlled systemic delivery of Salbutamol sulphate to avoid first pass hepatic metabolism. The developed patches were evaluated for the physicochemical, mechanical and drug release characteristics. The patches showed desired mechanical and physicochemical properties to withstand environment of oral cavity. The in-vitro release study showed that patches could deliver drug to the oral mucosa for a period of 7 h. the patches exhibited adequate stability when tested under accelerated conditions.

  7. A method for detecting hydrophobic patches protein

    NARCIS (Netherlands)

    Lijnzaad, P.; Berendsen, H.J.C.; Argos, P.

    1996-01-01

    A method for the detection of hydrophobic patches on the surfaces of protein tertiary structures is presented, it delineates explicit contiguous pieces of surface of arbitrary size and shape that consist solely of carbon and sulphur atoms using a dot representation of the solvent-accessible surface,

  8. Evaluation of winter pothole patching methods.

    Science.gov (United States)

    2014-01-01

    The main objective of this study was to evaluate the performance and cost-effectiveness of the tow-behind combination : infrared asphalt heater/reclaimer patching method and compare it to the throw and roll and spray injection methods. To : achieve t...

  9. Active patch antennas for transponder applications

    Energy Technology Data Exchange (ETDEWEB)

    Biffi Gentili, G; Avitabile, G; Bonifacio, F; Salvador, C [Florence Univ. (Italy). Dip. di Ingegneria Elettronica

    1996-01-01

    The paper deals with two patch antenna structures that are mainly taught for short range link and non-contact identification system (RFID). The proposed antennas were developed by starting from an original concept of cross-polarization usefully applicable, in compliance with european for transponder applications are described and experimental results are reported.

  10. Planar patch clamp: advances in electrophysiology.

    Science.gov (United States)

    Brüggemann, Andrea; Farre, Cecilia; Haarmann, Claudia; Haythornthwaite, Ali; Kreir, Mohamed; Stoelzle, Sonja; George, Michael; Fertig, Niels

    2008-01-01

    Ion channels have gained increased interest as therapeutic targets over recent years, since a growing number of human and animal diseases have been attributed to defects in ion channel function. Potassium channels are the largest and most diverse family of ion channels. Pharmaceutical agents such as Glibenclamide, an inhibitor of K(ATP) channel activity which promotes insulin release, have been successfully sold on the market for many years. So far, only a small group of the known ion channels have been addressed as potential drug targets. The functional testing of drugs on these ion channels has always been the bottleneck in the development of these types of pharmaceutical compounds.New generations of automated patch clamp screening platforms allow a higher throughput for drug testing and widen this bottleneck. Due to their planar chip design not only is a higher throughput achieved, but new applications have also become possible. One of the advantages of planar patch clamp is the possibility of perfusing the intracellular side of the membrane during a patch clamp experiment in the whole-cell configuration. Furthermore, the extracellular membrane remains accessible for compound application during the experiment.Internal perfusion can be used not only for patch clamp experiments with cell membranes, but also for those with artificial lipid bilayers. In this chapter we describe how internal perfusion can be applied to potassium channels expressed in Jurkat cells, and to Gramicidin channels reconstituted in a lipid bilayer.

  11. Perturbation analysis for patch occupancy dynamics

    Science.gov (United States)

    Martin, Julien; Nichols, James D.; McIntyre, Carol L.; Ferraz, Goncalo; Hines, James E.

    2009-01-01

    Perturbation analysis is a powerful tool to study population and community dynamics. This article describes expressions for sensitivity metrics reflecting changes in equilibrium occupancy resulting from small changes in the vital rates of patch occupancy dynamics (i.e., probabilities of local patch colonization and extinction). We illustrate our approach with a case study of occupancy dynamics of Golden Eagle (Aquila chrysaetos) nesting territories. Examination of the hypothesis of system equilibrium suggests that the system satisfies equilibrium conditions. Estimates of vital rates obtained using patch occupancy models are used to estimate equilibrium patch occupancy of eagles. We then compute estimates of sensitivity metrics and discuss their implications for eagle population ecology and management. Finally, we discuss the intuition underlying our sensitivity metrics and then provide examples of ecological questions that can be addressed using perturbation analyses. For instance, the sensitivity metrics lead to predictions about the relative importance of local colonization and local extinction probabilities in influencing equilibrium occupancy for rare and common species.

  12. Patch testing with the "sesquiterpene lactone mix"

    DEFF Research Database (Denmark)

    Ducombs, G; Benezra, C; Talaga, P

    1990-01-01

    6278 patients were patch tested with a sesquiterpene lactone mix (SL-mix) in 10 European clinics. 4011 patients were tested only with 0.1% SL-mix, 63 (approximately 1.5%) of whom were positive, with 26 (41%) of these cases being considered clinically relevant. There were no cases of active...

  13. Analgesic Microneedle Patch for Neuropathic Pain Therapy.

    Science.gov (United States)

    Xie, Xi; Pascual, Conrado; Lieu, Christopher; Oh, Seajin; Wang, Ji; Zou, Bende; Xie, Julian; Li, Zhaohui; Xie, James; Yeomans, David C; Wu, Mei X; Xie, Xinmin Simon

    2017-01-24

    Neuropathic pain caused by nerve injury is debilitating and difficult to treat. Current systemic pharmacological therapeutics for neuropathic pain produce limited pain relief and have undesirable side effects, while current local anesthetics tend to nonspecifically block both sensory and motor functions. Calcitonin gene related peptide (CGRP), a neuropeptide released from sensory nerve endings, appears to play a significant role in chronic neuropathic pain. In this study, an analgesic microneedle (AMN) patch was developed using dissolvable microneedles to transdermally deliver selective CGRP antagonist peptide in a painless manner for the treatment of localized neuropathic pain. Local analgesic effects were evaluated in rats by testing behavioral pain sensitivity in response to thermal and mechanical stimuli using neuropathic pain models such as spared-nerve injury and diabetic neuropathy pain, as well as neurogenic inflammatory pain model induced by ultraviolet B (UVB) radiation. Unlike several conventional therapies, the AMN patches produced effective analgesia on neuropathic pain without disturbing the normal nociception and motor function of the rat, resulting from the high specificity of the delivered peptide against CGRP receptors. The AMN patches did not cause skin irritation or systemic side effects. These results demonstrate that dissolvable microneedle patches delivering CGRP antagonist peptide provide an effective, safe, and simple approach to mitigate neuropathic pain with significant advantages over current treatments.

  14. Soil, Seeds, and the Pumpkin Patch!

    Science.gov (United States)

    Phillips, Marianne; Vowell, Julie

    2013-01-01

    "Soil, Seeds, and the Pumpkin Patch!" is an integrated unit designed to provide elementary school teachers with ideas for using hands-on activities, fostering inquiry and valuable discussion, and using technology as a learning tool. This unit integrates science with language arts, mathematics, literature, and technology. During this unit, students…

  15. Utilization of the UV laser with picosecond pulses for the formation of surface microstructures on elastomeric plastics

    Science.gov (United States)

    Antoszewski, B.; Tofil, S.; Scendo, M.; Tarelnik, W.

    2017-08-01

    Elastomeric plastics belong to a wide range of polymeric materials with special properties. They are used as construction material for seals and other components in many branches of industry and, in particular, in the biomedical industry, mechatronics, electronics and chemical equipment. The micromachining of surfaces of these materials can be used to build micro-flow, insulating, dispensing systems and chemical and biological reactors. The paper presents results of research on the effects of micro-machining of selected elastomeric plastics using a UV laser emitting picosecond pulses. The authors see the prospective application of the developed technology in the sealing technique in particular to shaping the sealing pieces co-operating with the surface of the element. The result of the study is meant to show parameters of the UV laser’s performance when producing typical components such as grooves, recesses for optimum ablation in terms of quality and productivity.

  16. Reactive bonding mediated high mass loading of individualized single-walled carbon nanotubes in an elastomeric polymer

    Science.gov (United States)

    Zhao, Liping; Li, Yongjin; Qiu, Jishan; You, Jichun; Dong, Wenyong; Cao, Xiaojun

    2012-09-01

    A reactive chemical bonding strategy was developed for the incorporation of a high mass loading of individual single-wall carbon nanotubes (SWCNTs) into an elastomeric matrix using a reactive ionic liquid as a linker. This method simultaneously prevented the agglomeration of SWCNTs and caused strong interfacial bonding, while the electronic properties of the SWCNTs remained intact. As a result, the high conductivity of the carbon nanotubes (CNTs) and the flexibility of the elastomeric matrix were retained, producing optimum electrical and mechanical properties. A composite material with a loading of 20 wt% SWCNTs was fabricated with excellent mechanical properties and a high conductivity (9500 S m-1). The method could be used to form transparent thin conductive films that could tolerate over 800 bend cycles at a bending angle of 180° while maintaining a constant sheet resistance.A reactive chemical bonding strategy was developed for the incorporation of a high mass loading of individual single-wall carbon nanotubes (SWCNTs) into an elastomeric matrix using a reactive ionic liquid as a linker. This method simultaneously prevented the agglomeration of SWCNTs and caused strong interfacial bonding, while the electronic properties of the SWCNTs remained intact. As a result, the high conductivity of the carbon nanotubes (CNTs) and the flexibility of the elastomeric matrix were retained, producing optimum electrical and mechanical properties. A composite material with a loading of 20 wt% SWCNTs was fabricated with excellent mechanical properties and a high conductivity (9500 S m-1). The method could be used to form transparent thin conductive films that could tolerate over 800 bend cycles at a bending angle of 180° while maintaining a constant sheet resistance. Electronic supplementary information (ESI) available: Conductivity test of the SEBS-SWCNTs film, transmission spectra and sheet resistance for the spin-coated SEBS-SWCNTs thin films on PET slides. See DOI: 10

  17. The effect of a lidocaine/prilocaine topical anesthetic on pain and discomfort associated with orthodontic elastomeric separator placement

    Directory of Open Access Journals (Sweden)

    M. Abu Al-Melh

    2017-01-01

    Full Text Available Abstract Background The initial placement of orthodontic elastomeric separators can be uncomfortable and painful. Therefore, it is important to relieve this disturbing sensation to create a discomfort or pain-free orthodontic visit. The purpose of this study was to investigate the effect of a lidocaine/prilocaine topical anesthetic on pain and discomfort associated with the placement of orthodontic elastomeric separators. Methods Fifty subjects aging between 20–35 years were included in this study. In the maxillary arch, a lidocaine/prilocaine topical anesthetic was placed around the ginigval margins of the premolar and molar on side. On the other side, a placebo agent was placed around the ginigval margins of the premolar and molar. After two minutes, an elastomeric separator was placed between the premolar and molar on both sides. The subjects were then asked to report their findings on a Verbal Scale and a Visual Analogue Scale every second minute for a period of 10 min. The subjects were also given a questionnaire to evaluate the overall impression on the topical anesthetic use. Results The overall mean discomfort/pain score was found to be significantly lower (p < 0.001 with the topical anesthetic than with the placebo. Repeated measures ANOVA with a Greenhouse-Geisser correction determined that mean pain scores were statistically significantly low with the 10-min time duration (F (1.54,42.2 = 40.7, p = 0.001, with an estimated grand mean (8.37, 95% CI 6.75–9.98. The questionnaire responses revealed that 87% of the subjects reported an overall satisfaction and agreement with the topical anesthetic than with the placebo or no difference (13% after the initial separator placement. Conclusions The discomfort and pain resulting from the initial placement of orthodontic elastomeric separators can be significantly reduced with the lidocaine/prilocaine topical anesthetic.

  18. Volatility of fragrance chemicals: patch testing implications.

    Science.gov (United States)

    Gilpin, Sarah J; Hui, Xiaoying; Maibach, Howard I

    2009-01-01

    Diagnostic and predictive patch testing to determine contact allergy due to fragrance materials requires applying a fixed dose of material to the skin. This dose can be affected by the volatile nature of fragrances; little data exist on how the loss of fragrance dose due to volatility affects patch testing. (1) To evaluate pH dependence and evaporation rates of two fragrance chemicals, geraniol, citronellol, and a common fragrance solvent, diethyl phthalate (DEP) and (2) Assess implications for predictive patch-testing methods for fragrances. pH analysis of each material at 1% for three values (4.0, 5.0, 7.0) was done over 40 hours. Volatility experiments for each material, nonradiolabeled and radiolabeled, were conducted over a 24-hour period, taking readings at six time points (5 minutes, 15 minutes, 40 minutes, 1 hour, 3 hours, and 24 hours). Evaporation rates were not sensitive to pH shifts from 4.0 to 7.0. Evaporation rates for nonradiolabeled materials were low: after 24 hours, geraniol lost 8.9%, citronellol 27.0% and DEP 14.5%. The volatility data for radiolabeled materials demonstrated that geraniol loses up to 39% of its dose, citronellol loses up to 26%, and DEP up to 14% within 40 minutes. The tendency of fragrance materials to evaporate can impact the dose being applied to the patch and therefore the result of the patch and ultimately the decision-making process regarding that fragrance material's safety. These data, developed with DEP, utilized in a predictive sensitization assay cannot be generalized.

  19. Light transmission and preference of eye patches for occlusion treatment.

    Directory of Open Access Journals (Sweden)

    Hwan Heo

    Full Text Available To investigate light transmission and preference for six eye patches for occlusion therapy.Six patches were examined, including; Ortopad Fun Pack, Ortopad Flesh, Kawamoto A-1, Kawamoto A-2, 3M Opticlude, and Everade Eye Guard. The size and the presence of a light blocking pad of patches were investigated. The amount of light transmitted through the patches was evaluated, using a digital light meter and a model eye, in three different environments; indoors with fluorescent light, outdoors on a sunny day, and strong light from illuminator. After patching the normal eye, the flash visual evoked potential (VEP was measured. Thirty patients with amblyopia or horizontal strabismus, who received occlusion therapy as initial treatment, were included. After using all six patches, patients completed a 7-item questionnaire regarding the patch preference for size, color and shape, adhesive power, pain with removal, skin irritation after removing patch, parent's preference and overall opinion.All patches had a light-blocking pad, except the 3M Nexcare. Ortopad had the strongest light blocking power in the three environments, and the 3M Nexcare had the weakest power. In flash VEP, Ortopad and Kawamoto patches showed flat, but 3M Nexcare and Everade Eye Guard showed normal response. There were significant preferential differences among the patches in all the items of the questionnaire (P<0.05. In comparison between the patches respectively, 3M Nexcare received the lowest satisfaction in pain when removing a patch and skin irritation after removing a patch. Kawamoto A-2 received the lowest score in the overall satisfaction.We found differences in the light-blocking power and in the preference of the various patches for the occlusion treatment. This is a pilot study regarding only characteristics and preferences of patches. Further clinical studies regarding the relationship between characteristics or preferences of patches and outcomes of occlusion treatment

  20. Properties of solutions in semi-hyperbolic patches for unsteady transonic small disturbance equations

    Directory of Open Access Journals (Sweden)

    Ilija Jegdic

    2015-09-01

    Full Text Available We consider a two-dimensional Riemann problem for the unsteady transonic small disturbance equation resulting in diverging rarefaction waves. We write the problem in self-similar coordinates and we obtain a mixed type (hyperbolic-elliptic system. Resolving the one-dimensional discontinuities in the far field, where the system is hyperbolic, and using characteristics, we formulate the problem in a semi-hyperbolic patch that is between the hyperbolic and the elliptic regions. A semi-hyperbolic patch is known as a region where one family out of two nonlinear families of characteristics starts on a sonic curve and ends on a transonic shock. We obtain existence of a smooth local solution in this semi-hyperbolic patch and we prove various properties of global smooth solutions based on a characteristic decomposition using directional derivatives.

  1. Regional Ecological Corridors - MLCCS derived 2008

    Data.gov (United States)

    Minnesota Department of Natural Resources — Identification of potential ecological corridors between the MLCCS derived ecological patches (ear_eco08py3). This was generated using cost / distance analysis,...

  2. Continued evaluation of pothole patching equipment, materials, and processes.

    Science.gov (United States)

    2014-06-14

    After the deaths of two Caltrans workers who were patching potholes in 2006-2007, Caltrans tasked the Advanced Highway Maintenance and Construction Technology (AHMCT) Research Center with developing a safer and more efficient means of patching pothol...

  3. In-use Stability of Ceftaroline Fosamil in Elastomeric Home Infusion Systems and MINI-BAG Plus Containers.

    Science.gov (United States)

    Bhattacharya, Sisir; Parekh, Satish; Dedhiya, Mahendra

    2015-01-01

    The objective of this study was to determine in-use stability of ceftaroline fosamil infusion solution of concentrations up to 12 mg/mL in elastomeric home infusion system prefilled with 0.9% Sodium Chloride Injection USP or 5% Dextrose Injection USP and MINI-BAG Plus Container delivery devices prefilled with 0.9% sodium chloride injection. In-use ceftaroline fosamil infusion solution (12 mg/mL) was prepared for elastomeric home infusion systems (Homepump Eclipse, Baxter Intermate, and AccuRx Elastomeric Pump) pre-filled with either 0.9% sodium chloride injection or 5% dextrose; or Baxter MINI-BAG Plus Containers pre-filled with 0.9% Sodium Chloride Injection USP (4 mg/mL to 12 mg/mL ceftaroline fosamil in final solution). The systems were stored refrigerated for 24 hours followed by up to 6 hours of storage at room temperature. Samples were analyzed at various time points for assay and degradation product by a validated stability-indicating high-performance liquid chromatography method. In-use ceftaroline fosamil infusion solution, ranging from 4-mg/mL to a maximum of 12-mg/mL concentration, in elastomeric home infusion systems prefilled with 0.9% sodium chloride injection or 5% dextrose, and MINI-BAG Plus Containers prefilled with 0.9% sodium chloride injection were chemically stable for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours at room temperature and had acceptable compatibility with material used. Ceftaroline fosamil (4 mg/mL to 12 mg/mL) maintains its potency for up to 24 hours refrigerated at 2°C to 8°C (36°F to 46°F) and up to 6 hours of storage at room temperature upon reconstitution in infusion solution with 0.9% sodium chloride or 5% dextrose when used in elastomeric home infusion system and MINI-BAG Plus Containers delivery devices prefilled with 0.9% sodium chloride injection.

  4. Corridor Length and Patch Colonization by a Butterfly Junonia coenia

    Energy Technology Data Exchange (ETDEWEB)

    Nick Haddad

    2000-06-01

    Habitat corridors have been proposed to reduce patch isolation and increase population persistence in fragmented landscapes. This study tested whether patch colonization was increased by the presence and various length corridors. The specific butterfly species tested has been shown to use corridors, however, the results indicate that neither the distance between patches or the presence of a corridor influenced colonization.

  5. Using an index of habitat patch proximity for landscape design

    Science.gov (United States)

    Eric J. Gustafson; George R. Parker

    1994-01-01

    A proximity index (PX) inspired by island biogeography theory is described which quantifies the spatial context of a habitat patch in relation to its neighbors. The index distinguishes sparse distributions of small habitat patches from clusters of large patches. An evaluation of the relationship between PX and variation in the spatial characteristics of clusters of...

  6. Smooth surfaces from rational bilinear patches

    KAUST Repository

    Shi, Ling

    2014-01-01

    Smooth freeform skins from simple panels constitute a challenging topic arising in contemporary architecture. We contribute to this problem area by showing how to approximate a negatively curved surface by smoothly joined rational bilinear patches. The approximation problem is solved with help of a new computational approach to the hyperbolic nets of Huhnen-Venedey and Rörig and optimization algorithms based on it. We also discuss its limits which lie in the topology of the input surface. Finally, freeform deformations based on Darboux transformations are used to generate smooth surfaces from smoothly joined Darboux cyclide patches; in this way we eliminate the restriction to surfaces with negative Gaussian curvature. © 2013 Elsevier B.V.

  7. Super wideband characteristics of monopolar patch antenna

    Directory of Open Access Journals (Sweden)

    Xi Chen

    2013-12-01

    Full Text Available A simple method of acquiring super wideband characteristics for monopolar patch antenna is proposed. Through adopting a modified cone as feeding and radiating structure, the monopolar patch antenna can reach the impedance bandwidth of more than 1:23.4 for voltage standing wave ratio (VSWR ≤ 2. In the whole operating band, the antenna has the like-monopole omnidirectional radiation patterns and the peak gains of 3.8–8.7 dB. Meanwhile, the height of the antenna is just 0.074λ(c, and the diameter of the radiated body is 0.205λ(c, which is smaller than other ultra-wideband omnidirectional antenna.

  8. Bilaterally Weighted Patches for Disparity Map Computation

    Directory of Open Access Journals (Sweden)

    Laura Fernández Julià

    2015-03-01

    Full Text Available Visual correspondence is the key for 3D reconstruction in binocular stereovision. Local methods perform block-matching to compute the disparity, or apparent motion, of pixels between images. The simplest approach computes the distance of patches, usually square windows, and assumes that all pixels in the patch have the same disparity. A prominent artifact of the method is the "foreground fattening effet" near depth discontinuities. In order to find a more appropriate support, Yoon and Kweon introduced the use of weights based on color similarity and spatial distance, analogous to those used in the bilateral filter. This paper presents the theory of this method and the implementation we have developed. Moreover, some variants are discussed and improvements are used in the final implementation. Several examples and tests are presented and the parameters and performance of the method are analyzed.

  9. Metamaterial Embedded Wearable Rectangular Microstrip Patch Antenna

    Directory of Open Access Journals (Sweden)

    J. G. Joshi

    2012-01-01

    Full Text Available This paper presents an indigenous low-cost metamaterial embedded wearable rectangular microstrip patch antenna using polyester substrate for IEEE 802.11a WLAN applications. The proposed antenna resonates at 5.10 GHz with a bandwidth and gain of 97 MHz and 4.92 dBi, respectively. The electrical size of this antenna is 0.254λ×0.5λ. The slots are cut in rectangular patch to reduce the bending effect. This leads to mismatch the impedance at WLAN frequency band; hence, a metamaterial square SRR is embedded inside the slot. A prototype antenna has been fabricated and tested, and the measured results are presented in this paper. The simulated and measured results of the proposed antenna are found to be in good agreement. The bending effect on the performance of this antenna is experimentally verified.

  10. Patch testing with hair cosmetic series in Europe

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Bensefa-Colas, Lynda; Frosch, Peter

    2015-01-01

    Many key ingredients of hair cosmetics (in particular, dyes, bleaches, and hair-styling agents) are potent (strong to extreme) contact allergens. Some heterogeneity is apparent from published results concerning the range of allergens for which patch testing is important. The objective...... of the present review was to collect information on the current practice of using 'hair cosmetic series', and discuss this against the background of evidence concerning consumer/professional exposure and regulatory aspects to finally derive a recommendation for a 'European hair cosmetic series'. The methods...... (Annex II of the Cosmetics Regulation). An up-to-date 'European hair cosmetics series', as recommended in the present article, should (i) include broadly used and/or potent contact allergens, (ii) eliminate substances of only historical concern, and (iii) be continually updated as new evidence emerges....

  11. Microstrip Patch Sensor for Salinity Determination.

    Science.gov (United States)

    Lee, Kibae; Hassan, Arshad; Lee, Chong Hyun; Bae, Jinho

    2017-12-18

    In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using conductivity change, since the relative permittivity change to salinity is 2.5 times more sensitive than the conductivity change. The patch and ground plane of the proposed sensor are fabricated by conductive copper spray coating on the masks made by 3D printer. The fabricated patch and the ground plane are bonded to a commercial silicon substrate and then attached to 5 mm-high chamber made by 3D printer so that it contains only 1 mL seawater. For easy fabrication and testing, the maximum resonance frequency was selected under 3 GHz and to cover salinities in real seawater, it was assumed that the salinity changes from 20 to 35 ppt. The sensor was designed by the finite element method-based ANSYS high-frequency structure simulator (HFSS), and it can detect the salinity with 0.01 ppt resolution. The designed sensor has a resonance frequency separation of 37.9 kHz and reflection coefficients under -20 dB at the resonant frequencies. The fabricated sensor showed better performance with average frequency separation of 48 kHz and maximum reflection coefficient of -35 dB. By comparing with the existing sensors, the proposed compact and low-cost sensor showed a better detection capability. Therefore, the proposed patch sensor can be utilized in radio frequency (RF) tunable sensors for salinity determination.

  12. Microstrip Patch Sensor for Salinity Determination

    Directory of Open Access Journals (Sweden)

    Kibae Lee

    2017-12-01

    Full Text Available In this paper, a compact microstrip feed inset patch sensor is proposed for measuring the salinities in seawater. The working principle of the proposed sensor depends on the fact that different salinities in liquid have different relative permittivities and cause different resonance frequencies. The proposed sensor can obtain better sensitivity to salinity changes than common sensors using conductivity change, since the relative permittivity change to salinity is 2.5 times more sensitive than the conductivity change. The patch and ground plane of the proposed sensor are fabricated by conductive copper spray coating on the masks made by 3D printer. The fabricated patch and the ground plane are bonded to a commercial silicon substrate and then attached to 5 mm-high chamber made by 3D printer so that it contains only 1 mL seawater. For easy fabrication and testing, the maximum resonance frequency was selected under 3 GHz and to cover salinities in real seawater, it was assumed that the salinity changes from 20 to 35 ppt. The sensor was designed by the finite element method-based ANSYS high-frequency structure simulator (HFSS, and it can detect the salinity with 0.01 ppt resolution. The designed sensor has a resonance frequency separation of 37.9 kHz and reflection coefficients under −20 dB at the resonant frequencies. The fabricated sensor showed better performance with average frequency separation of 48 kHz and maximum reflection coefficient of −35 dB. By comparing with the existing sensors, the proposed compact and low-cost sensor showed a better detection capability. Therefore, the proposed patch sensor can be utilized in radio frequency (RF tunable sensors for salinity determination.

  13. Static characterization of a soft elastomeric capacitor for non destructive evaluation applications

    International Nuclear Information System (INIS)

    Saleem, Hussam; Laflamme, Simon; Zhang, Huanhuan; Geiger, Randall; Kessler, Michael; Rajan, Krishna

    2014-01-01

    A large and flexible strain transducer consisting of a soft elastomeric capacitor (SEC) has been proposed by the authors. Arranged in a network setup, the sensing strategy offers tremendous potential at conducting non-destructive evaluation of large-scale surfaces. In prior work, the authors have demonstrated the performance of the sensor at tracking strain history, localizing cracks, and detecting vibration signatures. In this paper, we characterize the static performance of the proposed SEC. The characterization includes sensitivity of the signal, and temperature and humidity dependences. Tests are conducted on a simply supported aluminum beam subjected to bending as well as on a free standing sensor. The performance of the SEC is compared against off-the-shelf resistance-based strain gauges with resolution of 1 με. A sensitivity of 1190 pF/ε is obtained experimentally, in agreement with theory. Results also show the sensor linearity over the given level of strain, showing the promise of the SEC at monitoring of surface strain

  14. Static characterization of a soft elastomeric capacitor for non destructive evaluation applications

    Science.gov (United States)

    Saleem, Hussam; Laflamme, Simon; Zhang, Huanhuan; Geiger, Randall; Kessler, Michael; Rajan, Krishna

    2014-02-01

    A large and flexible strain transducer consisting of a soft elastomeric capacitor (SEC) has been proposed by the authors. Arranged in a network setup, the sensing strategy offers tremendous potential at conducting non-destructive evaluation of large-scale surfaces. In prior work, the authors have demonstrated the performance of the sensor at tracking strain history, localizing cracks, and detecting vibration signatures. In this paper, we characterize the static performance of the proposed SEC. The characterization includes sensitivity of the signal, and temperature and humidity dependences. Tests are conducted on a simply supported aluminum beam subjected to bending as well as on a free standing sensor. The performance of the SEC is compared against off-the-shelf resistance-based strain gauges with resolution of 1 μɛ. A sensitivity of 1190 pF/ɛ is obtained experimentally, in agreement with theory. Results also show the sensor linearity over the given level of strain, showing the promise of the SEC at monitoring of surface strain.

  15. Caterpillar locomotion-inspired valveless pneumatic micropump using a single teardrop-shaped elastomeric membrane

    KAUST Repository

    So, Hongyun; Pisano, Albert P.; Seo, Young Ho

    2014-01-01

    This paper presents a microfluidic pump operated by an asymmetrically deformed membrane, which was inspired by caterpillar locomotion. Almost all mechanical micropumps consist of two major components of fluid halting and fluid pushing parts, whereas the proposed caterpillar locomotion-inspired micropump has only a single, bilaterally symmetric membrane-like teardrop shape. A teardrop-shaped elastomeric membrane was asymmetrically deformed and then consecutively touched down to the bottom of the chamber in response to pneumatic pressure, thus achieving fluid pushing. Consecutive touchdown motions of the teardrop-shaped membrane mimicked the propagation of a caterpillar's hump during its locomotory gait. The initial touchdown motion of the teardrop-shaped membrane at the centroid worked as a valve that blocked the inlet channel, and then, the consecutive touchdown motions pushed fluid in the chamber toward the tail of the chamber connected to the outlet channel. The propagation of the touchdown motion of the teardrop-shaped membrane was investigated using computational analysis as well as experimental studies. This caterpillar locomotion-inspired micropump composed of only a single membrane can provide new opportunities for simple integration of microfluidic systems. © the Partner Organisations 2014.

  16. Patterning the Stiffness of Elastomeric Nanocomposites by Magnetophoretic Control of Cross-linking Impeder Distribution

    Directory of Open Access Journals (Sweden)

    Suvojit Ghosh

    2015-01-01

    Full Text Available We report a novel method to pattern the stiffness of an elastomeric nanocomposite by selectively impeding the cross-linking reactions at desired locations while curing. This is accomplished by using a magnetic field to enforce a desired concentration distribution of colloidal magnetite nanoparticles (MNPs in the liquid precursor of polydimethysiloxane (PDMS elastomer. MNPs impede the cross-linking of PDMS; when they are dispersed in liquid PDMS, the cured elastomer exhibits lower stiffness in portions containing a higher nanoparticle concentration. Consequently, a desired stiffness pattern is produced by selecting the required magnetic field distribution a priori. Up to 200% variation in the reduced modulus is observed over a 2 mm length, and gradients of up to 12.6 MPa·mm−1 are obtained. This is a significant improvement over conventional nanocomposite systems where only small unidirectional variations can be achieved by varying nanoparticle concentration. The method has promising prospects in additive manufacturing; it can be integrated with existing systems thereby adding the capability to produce microscale heterogeneities in mechanical properties.

  17. Synthesis of polyester urethane urea and fabrication of elastomeric nanofibrous scaffolds for myocardial regeneration

    Energy Technology Data Exchange (ETDEWEB)

    Jamadi, Elham Sadat; Ghasemi-Mobarakeh, Laleh [Department of Textile engineering, Isfahan university of technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Morshed, Mohammad, E-mail: morshed@cc.iut.ac.ir [Department of Textile engineering, Isfahan university of technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Sadeghi, Morteza [Department of Chemical Engineering, Isfahan university of technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Prabhakaran, Molamma P., E-mail: nanotechmpp@gmail.com [Department of Mechanical Engineering, Faculty of Engineering, 2 Engineering Drive 3, National University of Singapore, Singapore 117576 (Singapore); Ramakrishna, Seeram [Department of Mechanical Engineering, Faculty of Engineering, 2 Engineering Drive 3, National University of Singapore, Singapore 117576 (Singapore)

    2016-06-01

    Fabrication of bioactive scaffolds is one of the most promising strategies to reconstruct the infarcted myocardium. In this study, we synthesized polyester urethane urea (PEUU), further blended it with gelatin and fabricated PEUU/G nanofibrous scaffolds. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), differential scanning calorimetry (DSC) and X-ray diffraction were used for the characterization of the synthesized PEUU and properties of nanofibrous scaffolds were evaluated using scanning electron microscopy (SEM), ATR-FTIR, contact angle measurement, biodegradation test, tensile strength analysis and dynamic mechanical analysis (DMA). In vitro biocompatibility studies were performed using cardiomyocytes. DMA analysis showed that the scaffolds could be reshaped with cyclic deformations and might remain stable in the frequencies of the physiological activity of the heart. On the whole, our study suggests that aligned PEUU/G 70:30 nanofibrous scaffolds meet the required specifications for cardiac tissue engineering and could be used as a promising construct for myocardial regeneration. - Highlights: • PEUU was synthesized to fabricate elastomeric scaffolds for myocardial regeneration. • FTIR, DSC and XRD analysis showed that polymer synthesis was well. • PEUU/gelatin nanofibrous scaffolds could be reshaped with cyclic deformations of the heart. • Gelatin in structure of PEUU nanofibers improved proliferation of cardiomyocytes. • Aligned PEUU/gelatin 70:30 nanofibrous scaffold support the alignment of cardiomyocytes.

  18. Highly Magneto-Responsive Elastomeric Films Created by a Two-Step Fabrication Process

    KAUST Repository

    Marchi, Sophie

    2015-08-24

    An innovative method for the preparation of elastomeric magnetic films with increased magneto-responsivity is presented. Polymeric films containing aligned magnetic microchains throughout their thickness are formed upon the magnetophoretic transport and assembly of microparticles during polymer curing. The obtained films are subsequently magnetized at a high magnetic field of 3 T directed parallel to the orientation of the microchains. We prove that the combination of both alignment of the particles along a favorable direction during curing and the subsequent magnetization of the solid films induces an impressive increase of the films’ deflection. Specifically, the displacements reach few millimeters, up to 85 times higher than those of the nontreated films with the same particle concentration. Such a process can improve the performance of the magnetic films without increasing the amount of magnetic fillers and, thus, without compromising the mechanical properties of the resulting composites. The proposed method can be used for the fabrication of magnetic films suitable as components in systems in which large displacements at relatively low magnetic fields are required, such as sensors and drug delivery or microfluidic systems, especially where remote control of valves is requested to achieve appropriate flow and mixing of liquids.

  19. Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery

    Science.gov (United States)

    De Falco, Iris; Gerboni, Giada; Cianchetti, Matteo; Menciassi, Arianna

    2015-01-01

    In recent years, soft robotics technologies have aroused increasing interest in the medical field due to their intrinsically safe interaction in unstructured environments. At the same time, new procedures and techniques have been developed to reduce the invasiveness of surgical operations. Minimally Invasive Surgery (MIS) has been successfully employed for abdominal interventions, however standard MIS procedures are mainly based on rigid or semi-rigid tools that limit the dexterity of the clinician. This paper presents a soft and high dexterous manipulator for MIS. The manipulator was inspired by the biological capabilities of the octopus arm, and is designed with a modular approach. Each module presents the same functional characteristics, thus achieving high dexterity and versatility when more modules are integrated. The paper details the design, fabrication process and the materials necessary for the development of a single unit, which is fabricated by casting silicone inside specific molds. The result consists in an elastomeric cylinder including three flexible pneumatic actuators that enable elongation and omni-directional bending of the unit. An external braided sheath improves the motion of the module. In the center of each module a granular jamming-based mechanism varies the stiffness of the structure during the tasks. Tests demonstrate that the module is able to bend up to 120° and to elongate up to 66% of the initial length. The module generates a maximum force of 47 N, and its stiffness can increase up to 36%. PMID:26650236

  20. Methodology for Evaluating Raw Material Changes to RSRM Elastomeric Insulation Materials

    Science.gov (United States)

    Mildenhall, Scott D.; McCool, Alex (Technical Monitor)

    2001-01-01

    The Reusable Solid Rocket Motor (RSRM) uses asbestos and silicon dioxide filled acrylonitrile butadiene rubber (AS-NBR) as the primary internal insulation to protect the case from heat. During the course of the RSRM Program, several changes have been made to the raw materials and processing of the AS-NBR elastomeric insulation material. These changes have been primarily caused by raw materials becoming obsolete. In addition, some process changes have been implemented that were deemed necessary to improve the quality and consistency of the AS-NBR insulation material. Each change has been evaluated using unique test efforts customized to determine the potential impacts of the specific raw material or process change. Following the evaluations, the various raw material and process changes were successfully implemented with no detectable effect on the performance of the AS-NBR insulation. This paper will discuss some of the raw material and process changes evaluated, the methodology used in designing the unique test plans, and the general evaluation results. A summary of the change history of RSRM AS-NBR internal insulation is also presented.

  1. Influence of particle arrangement on the permittivity of an elastomeric composite

    Directory of Open Access Journals (Sweden)

    Peiying J. Tsai

    2017-01-01

    Full Text Available Elastomers are used as dielectric layers contained between the parallel conductive plates of capacitors. The introduction of filler particles into an elastomer changes its permittivity ε. When particle organization in a composite is intentionally varied, this alters its capacitance. Using numerical simulations, we examine how conductive particle chains introduced into polydimethylsiloxane (PDMS alter ε. The effects of filler volume fraction ψ, interparticle d and interchain spacing a, zigzag angle θ between adjacent particles and overall chain orientation, particle size r, and clearance h between particles and the conductive plates are characterized. When filler particles are organized into chainlike structures rather than being just randomly distributed in the elastomer matrix, ε increases by as much as 85%. When particles are organized into chainlike forms, ε increases with increasing ψ and a, but decreases with increasing d and θ. A composite containing smaller particles has a higher ε when ψ<9% while larger particles provide greater enhancement when ψ is larger than that value. To enhance ε, adjacent particles must be interconnected and the overall chain direction should be oriented perpendicular to the conductive plates. These results are useful for additive manufacturing on electrical applications of elastomeric composites.

  2. Highly Magneto-Responsive Elastomeric Films Created by a Two-Step Fabrication Process

    KAUST Repository

    Marchi, Sophie; Casu, Alberto; Bertora, Franco; Athanassiou, Athanassia; Fragouli, Despina

    2015-01-01

    An innovative method for the preparation of elastomeric magnetic films with increased magneto-responsivity is presented. Polymeric films containing aligned magnetic microchains throughout their thickness are formed upon the magnetophoretic transport and assembly of microparticles during polymer curing. The obtained films are subsequently magnetized at a high magnetic field of 3 T directed parallel to the orientation of the microchains. We prove that the combination of both alignment of the particles along a favorable direction during curing and the subsequent magnetization of the solid films induces an impressive increase of the films’ deflection. Specifically, the displacements reach few millimeters, up to 85 times higher than those of the nontreated films with the same particle concentration. Such a process can improve the performance of the magnetic films without increasing the amount of magnetic fillers and, thus, without compromising the mechanical properties of the resulting composites. The proposed method can be used for the fabrication of magnetic films suitable as components in systems in which large displacements at relatively low magnetic fields are required, such as sensors and drug delivery or microfluidic systems, especially where remote control of valves is requested to achieve appropriate flow and mixing of liquids.

  3. Caterpillar locomotion-inspired valveless pneumatic micropump using a single teardrop-shaped elastomeric membrane

    KAUST Repository

    So, Hongyun

    2014-01-01

    This paper presents a microfluidic pump operated by an asymmetrically deformed membrane, which was inspired by caterpillar locomotion. Almost all mechanical micropumps consist of two major components of fluid halting and fluid pushing parts, whereas the proposed caterpillar locomotion-inspired micropump has only a single, bilaterally symmetric membrane-like teardrop shape. A teardrop-shaped elastomeric membrane was asymmetrically deformed and then consecutively touched down to the bottom of the chamber in response to pneumatic pressure, thus achieving fluid pushing. Consecutive touchdown motions of the teardrop-shaped membrane mimicked the propagation of a caterpillar\\'s hump during its locomotory gait. The initial touchdown motion of the teardrop-shaped membrane at the centroid worked as a valve that blocked the inlet channel, and then, the consecutive touchdown motions pushed fluid in the chamber toward the tail of the chamber connected to the outlet channel. The propagation of the touchdown motion of the teardrop-shaped membrane was investigated using computational analysis as well as experimental studies. This caterpillar locomotion-inspired micropump composed of only a single membrane can provide new opportunities for simple integration of microfluidic systems. © the Partner Organisations 2014.

  4. Optimal elastomeric scaffold leaflet shape for pulmonary heart valve leaflet replacement.

    Science.gov (United States)

    Fan, Rong; Bayoumi, Ahmed S; Chen, Peter; Hobson, Christopher M; Wagner, William R; Mayer, John E; Sacks, Michael S

    2013-02-22

    Surgical replacement of the pulmonary valve (PV) is a common treatment option for congenital pulmonary valve defects. Engineered tissue approaches to develop novel PV replacements are intrinsically complex, and will require methodical approaches for their development. Single leaflet replacement utilizing an ovine model is an attractive approach in that candidate materials can be evaluated under valve level stresses in blood contact without the confounding effects of a particular valve design. In the present study an approach for optimal leaflet shape design based on finite element (FE) simulation of a mechanically anisotropic, elastomeric scaffold for PV replacement is presented. The scaffold was modeled as an orthotropic hyperelastic material using a generalized Fung-type constitutive model. The optimal shape of the fully loaded PV replacement leaflet was systematically determined by minimizing the difference between the deformed shape obtained from FE simulation and an ex-vivo microCT scan of a native ovine PV leaflet. Effects of material anisotropy, dimensional changes of PV root, and fiber orientation on the resulting leaflet deformation were investigated. In-situ validation demonstrated that the approach could guide the design of the leaflet shape for PV replacement surgery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Biodegradable, elastomeric coatings with controlled anti-proliferative agent release for magnesium-based cardiovascular stents.

    Science.gov (United States)

    Gu, Xinzhu; Mao, Zhongwei; Ye, Sang-Ho; Koo, Youngmi; Yun, Yeoheung; Tiasha, Tarannum R; Shanov, Vesselin; Wagner, William R

    2016-08-01

    Vascular stent design continues to evolve to further improve the efficacy and minimize the risks associated with these devices. Drug-eluting coatings have been widely adopted and, more recently, biodegradable stents have been the focus of extensive evaluation. In this report, biodegradable elastomeric polyurethanes were synthesized and applied as drug-eluting coatings for a relatively new class of degradable vascular stents based on Mg. The dynamic degradation behavior, hemocompatibility and drug release were investigated for poly(carbonate urethane) urea (PCUU) and poly(ester urethane) urea (PEUU) coated magnesium alloy (AZ31) stents. Poly(lactic-co-glycolic acid) (PLGA) coated and bare stents were employed as control groups. The PCUU coating effectively slowed the Mg alloy corrosion in dynamic degradation testing compared to PEUU-coated, PLGA-coated and bare Mg alloy stents. This was confirmed by electron microscopy, energy-dispersive x-ray spectroscopy and magnesium ion release experiments. PCUU-coating of AZ31 was also associated with significantly reduced platelet adhesion in acute blood contact testing. Rat vascular smooth muscle cell (rSMC) proliferation was successfully inhibited when paclitaxel was released from pre-loaded PCUU coatings. The corrosion retardation, low thrombogenicity, drug loading capacity, and high elasticity make PCUU an attractive option for drug eluting coating on biodegradable metallic cardiovascular stents. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Accuracy of a new elastomeric impression material for complete-arch dental implant impressions.

    Science.gov (United States)

    Baig, Mirza R; Buzayan, Muaiyed M; Yunus, Norsiah

    2018-05-01

    The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts. Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05. The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05). The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions. © 2018 John Wiley & Sons Australia, Ltd.

  7. Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery.

    Science.gov (United States)

    De Falco, Iris; Gerboni, Giada; Cianchetti, Matteo; Menciassi, Arianna

    2015-11-14

    In recent years, soft robotics technologies have aroused increasing interest in the medical field due to their intrinsically safe interaction in unstructured environments. At the same time, new procedures and techniques have been developed to reduce the invasiveness of surgical operations. Minimally Invasive Surgery (MIS) has been successfully employed for abdominal interventions, however standard MIS procedures are mainly based on rigid or semi-rigid tools that limit the dexterity of the clinician. This paper presents a soft and high dexterous manipulator for MIS. The manipulator was inspired by the biological capabilities of the octopus arm, and is designed with a modular approach. Each module presents the same functional characteristics, thus achieving high dexterity and versatility when more modules are integrated. The paper details the design, fabrication process and the materials necessary for the development of a single unit, which is fabricated by casting silicone inside specific molds. The result consists in an elastomeric cylinder including three flexible pneumatic actuators that enable elongation and omni-directional bending of the unit. An external braided sheath improves the motion of the module. In the center of each module a granular jamming-based mechanism varies the stiffness of the structure during the tasks. Tests demonstrate that the module is able to bend up to 120° and to elongate up to 66% of the initial length. The module generates a maximum force of 47 N, and its stiffness can increase up to 36%.

  8. Durability assessment of soft elastomeric capacitor skin for SHM of wind turbine blades

    Science.gov (United States)

    Downey, Austin; Pisello, Anna Laura; Fortunati, Elena; Fabiani, Claudia; Luzi, Francesca; Torre, Luigi; Ubertini, Filippo; Laflamme, Simon

    2018-03-01

    Renewable energy production has become a key research driver during the last decade. Wind energy represents a ready technology for large-scale implementation in locations all around the world. While important research is conducted to optimize wind energy production efficiency, a critical issue consists of monitoring the structural integrity and functionality of these large structures during their operational life cycle. This paper investigates the durability of a soft elastomeric capacitor strain sensing membrane, designed for structural health monitoring of wind turbines, when exposed to aggressive environmental conditions. The sensor is a capacitor made of three thin layers of an SEBS polymer in a sandwich configuration. The inner layer is doped with titania and acts as the dielectric, while the external layers are filled with carbon black and work as the conductive plates. Here, a variety of samples, not limited to the sensor configuration but also including its dielectric layer, were fabricated and tested within an accelerated weathering chamber (QUV) by simulating thermal, humidity, and UV radiation cycles. A variety of other tests were performed in order to characterize their mechanical, thermal, and electrical performance in addition to their solar reflectance. These tests were carried out before and after the QUV exposures of 1, 7, 15, and 30 days. The tests showed that titania inclusions improved the sensor durability against weathering. These findings contribute to better understanding the field behavior of these skin sensors, while future developments will concern the analysis of the sensing properties of the skin after aging.

  9. Liquid gating elastomeric porous system with dynamically controllable gas/liquid transport.

    Science.gov (United States)

    Sheng, Zhizhi; Wang, Honglong; Tang, Yongliang; Wang, Miao; Huang, Lizhi; Min, Lingli; Meng, Haiqiang; Chen, Songyue; Jiang, Lei; Hou, Xu

    2018-02-01

    The development of membrane technology is central to fields ranging from resource harvesting to medicine, but the existing designs are unable to handle the complex sorting of multiphase substances required for many systems. Especially, the dynamic multiphase transport and separation under a steady-state applied pressure have great benefits for membrane science, but have not been realized at present. Moreover, the incorporation of precisely dynamic control with avoidance of contamination of membranes remains elusive. We show a versatile strategy for creating elastomeric microporous membrane-based systems that can finely control and dynamically modulate the sorting of a wide range of gases and liquids under a steady-state applied pressure, nearly eliminate fouling, and can be easily applied over many size scales, pressures, and environments. Experiments and theoretical calculation demonstrate the stability of our system and the tunability of the critical pressure. Dynamic transport of gas and liquid can be achieved through our gating interfacial design and the controllable pores' deformation without changing the applied pressure. Therefore, we believe that this system will bring new opportunities for many applications, such as gas-involved chemical reactions, fuel cells, multiphase separation, multiphase flow, multiphase microreactors, colloidal particle synthesis, and sizing nano/microparticles.

  10. Influence of particle arrangement on the permittivity of an elastomeric composite

    Science.gov (United States)

    Tsai, Peiying J.; Nayak, Suchitra; Ghosh, Suvojit; Puri, Ishwar K.

    2017-01-01

    Elastomers are used as dielectric layers contained between the parallel conductive plates of capacitors. The introduction of filler particles into an elastomer changes its permittivity ɛ. When particle organization in a composite is intentionally varied, this alters its capacitance. Using numerical simulations, we examine how conductive particle chains introduced into polydimethylsiloxane (PDMS) alter ɛ. The effects of filler volume fraction ψ, interparticle d and interchain spacing a, zigzag angle θ between adjacent particles and overall chain orientation, particle size r, and clearance h between particles and the conductive plates are characterized. When filler particles are organized into chainlike structures rather than being just randomly distributed in the elastomer matrix, ɛ increases by as much as 85%. When particles are organized into chainlike forms, ɛ increases with increasing ψ and a, but decreases with increasing d and θ. A composite containing smaller particles has a higher ɛ when ψ <9 % while larger particles provide greater enhancement when ψ is larger than that value. To enhance ɛ, adjacent particles must be interconnected and the overall chain direction should be oriented perpendicular to the conductive plates. These results are useful for additive manufacturing on electrical applications of elastomeric composites.

  11. Optimal patch code design via device characterization

    Science.gov (United States)

    Wu, Wencheng; Dalal, Edul N.

    2012-01-01

    In many color measurement applications, such as those for color calibration and profiling, "patch code" has been used successfully for job identification and automation to reduce operator errors. A patch code is similar to a barcode, but is intended primarily for use in measurement devices that cannot read barcodes due to limited spatial resolution, such as spectrophotometers. There is an inherent tradeoff between decoding robustness and the number of code levels available for encoding. Previous methods have attempted to address this tradeoff, but those solutions have been sub-optimal. In this paper, we propose a method to design optimal patch codes via device characterization. The tradeoff between decoding robustness and the number of available code levels is optimized in terms of printing and measurement efforts, and decoding robustness against noises from the printing and measurement devices. Effort is drastically reduced relative to previous methods because print-and-measure is minimized through modeling and the use of existing printer profiles. Decoding robustness is improved by distributing the code levels in CIE Lab space rather than in CMYK space.

  12. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Andreasen, Daniel, E-mail: dana@dtu.dk [Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark and Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev (Denmark); Van Leemput, Koen [Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark and A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts 02129 (United States); Edmund, Jens M. [Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev (Denmark)

    2016-08-15

    Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better

  13. Reinforcement of a plate weakened by multiple holes with several patches for different types of plate-patch attachment

    KAUST Repository

    Zemlyanova, A.

    2014-01-01

    the boundary of the patch or both along the boundary of the patch and the boundaries of the holes which this patch covers. The unattached boundaries of the holes may be loaded with given in-plane stresses. The mechanical problem is reduced to a system

  14. Miniaturization of Multiple-Layer Folded Patch Antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Breinbjerg, Olav

    2009-01-01

    A new folded patch antenna with multiple layers was developed in this paper, by folding the patch in a proper way, and a highly miniaturized antenna can be realized. The multiple layer patch with 4-layer and 6-layer are designed and evaluated at 2.4 GHz, 915 MHz, and 415 MHz respectively. Then a 4...... layer patch is fabricated and measured to validate the design method. The theoretical analysis, design and simulations, fabrications, as well as the measurements are presented in this paper. All the results show that the folded patch antenna is a good candidate in making a highly miniaturized compact...

  15. Sub-Patch Roughness in Earthquake Rupture Investigations

    KAUST Repository

    Zielke, Olaf; Mai, Paul Martin

    2016-01-01

    Fault geometric complexities exhibit fractal characteristics over a wide range of spatial scales (<µm to >km) and strongly affect the rupture process at corresponding scales. Numerical rupture simulations provide a framework to quantitatively investigate the relationship between a fault's roughness and its seismic characteristics. Fault discretization however introduces an artificial lower limit to roughness. Individual fault patches are planar and sub-patch roughness –roughness at spatial scales below fault-patch size– is not incorporated. Does negligence of sub-patch roughness measurably affect the outcome of earthquake rupture simulations? We approach this question with a numerical parameter space investigation and demonstrate that sub-patch roughness significantly modifies the slip-strain relationship –a fundamental aspect of dislocation theory. Faults with sub-patch roughness induce less strain than their planar-fault equivalents at distances beyond the length of a slipping fault. We further provide regression functions that characterize the stochastic effect sub-patch roughness.

  16. Reinforcement of a plate weakened by multiple holes with several patches for different types of plate-patch attachment

    KAUST Repository

    Zemlyanova, A.

    2014-01-24

    The most general situation of the reinforcement of a plate with multiple holes by several patches is considered. There is no restriction on the number and the location of the patches. Two types of patch attachment are considered: only along the boundary of the patch or both along the boundary of the patch and the boundaries of the holes which this patch covers. The unattached boundaries of the holes may be loaded with given in-plane stresses. The mechanical problem is reduced to a system of singular integral equations which can be further reduced to a system of Fredholm equations. A new numerical procedure for the solution of the system of singular integral equations is proposed in this paper. It is demonstrated on numerical examples that this procedure has advantages in the case of multiple patches and holes and allows achievement of better numerical convergence with less computational effort.

  17. Fine-Tuning on the Effective Patch Radius Expression of the Circular Microstrip Patch Antennas

    Directory of Open Access Journals (Sweden)

    A. E. Yilmaz

    2010-09-01

    Full Text Available In this study, the effective patch radius expression for the circular microstrip antennas is improved by means of several manipulations. Departing from previously proposed equations in the literature, one of the most accurate equations is picked up, and this equation is fine-tuned by means of Particle Swarm Optimization technique. Throughout the study, impacts of other parameters (such as the definition of the fitness/objective function, the degree-of-freedom in the proposed effective patch radius expression, the number of measured resonant frequency values are observed in a controlled manner. Finally, about 3% additional improvement is achieved over a very accurate formula, which was proposed earlier.

  18. Forces released during alignment with a preadjusted appliances with SPEED supercable wire and different types of elastomeric ligatures

    Directory of Open Access Journals (Sweden)

    Suruchi Jatol-Tekade

    2016-01-01

    Full Text Available Introduction: The purpose of this in vitro study was to evaluate a new combination of wire and ligature to reduce friction further by combining slide ligatures and supercable wires. Materials and Methods: The testing model consisted of five stainless steel 0.022 inch preadjusted brackets for second premolar, first premolar, canine, lateral incisor, and central incisor. The canine bracket was welded to a sliding bar that allowed different vertical positions. The forces generated by five sizes of wires superelastic nickel-titanium (SE Ni-Ti (Unitek Nitinol Super-Elastic Archwire of diameter 0.012", 0.014", 0.016", 0.018", and 0.020" inch and three sizes of SPEED supercable wires (0.016", 0.018", and 0.022" inch with the two types of elastomeric ligatures; conventional elastomeric ligatures (CELs (Unitek, silver mini modules, with inside diameter of 1.3 mm and thickness of 0.9 mm and nonconventional elastomeric ligatures (NCELs (Slide, Leone Orthodontic Products, Sesto Fiorentino, Firenze, Italy at different amounts of upward canine misalignment (CM (1.5, 3, 4.5, and 6 mm were recorded. Results and Conclusions: Significant differences between CEL and NCEL were found for all tested variables (P - 0.01 a noticeable amount of force was generated with the NCEL at all four canine positions with all three wire sizes (from about 50 to about 150 g. With 4.5 mm of CM or more, the average amount of released force with the CEL was approximately zero.

  19. Learning Dictionaries of Discriminative Image Patches

    DEFF Research Database (Denmark)

    Dahl, Anders Lindbjerg; Larsen, Rasmus

    2011-01-01

    using dictionaries of image patches with associated label data. The approach is based on ideas from sparse generative image models and texton based texture modeling. The intensity and label dictionaries are learned from training images with associated label information of (a subset) of the pixels based...... on a modified vector quantization approach. For new images the intensity dictionary is used to encode the image data and the label dictionary is used to build a segmentation of the image. We demonstrate the algorithm on composite and real texture images and show how successful training is possible even...

  20. Biological cell controllable patch-clamp microchip

    Science.gov (United States)

    Penmetsa, Siva; Nagrajan, Krithika; Gong, Zhongcheng; Mills, David; Que, Long

    2010-12-01

    A patch-clamp (PC) microchip with cell sorting and positioning functions is reported, which can avoid drawbacks of random cell selection or positioning for a PC microchip. The cell sorting and positioning are enabled by air bubble (AB) actuators. AB actuators are pneumatic actuators, in which air pressure is generated by microheaters within sealed microchambers. The sorting, positioning, and capturing of 3T3 cells by this type of microchip have been demonstrated. Using human breast cancer cells MDA-MB-231 as the model, experiments have been demonstrated by this microchip as a label-free technical platform for real-time monitoring of the cell viability.

  1. A decision algorithm for patch spraying

    DEFF Research Database (Denmark)

    Christensen, Svend; Heisel, Torben; Walter, Mette

    2003-01-01

    method that estimates an economic optimal herbicide dose according to site-specific weed composition and density is presented in this paper. The method was termed a ‘decision algorithm for patch spraying’ (DAPS) and was evaluated in a 5-year experiment, in Denmark. DAPS consists of a competition model......, a herbicide dose–response model and an algorithm that estimates the economically optimal doses. The experiment was designed to compare herbicide treatments with DAPS recommendations and the Danish decision support system PC-Plant Protection. The results did not show any significant grain yield difference...

  2. Patch testing with Indian standard series

    Directory of Open Access Journals (Sweden)

    Narendra G

    2002-01-01

    Full Text Available Hundred patients (61 males, 39 females suspected to have allergic contact dermatitis were patch tested with Indian standard series (ISS. Forty four showed one or more positive reactions. The frequent sensitizers observed were nickel sulphate-12 (15%, potassium dichromate-11 (13.75%, cobalt chloride and colophony-7 (8.75% each, fragrance mix and thiuram mix-6 (7.5% each. The ISS differs from the European Standard Series by inclusion of propylene glycol, nitrofurazone, gentamicin, chlorocresol, PEG-400 and ethylenediamine chloride where assesquiterpene lactone mix and primin allergens are excluded.

  3. Lidocaine patches reduce pain in trauma patients with rib fractures.

    Science.gov (United States)

    Zink, Karen A; Mayberry, John C; Peck, Ellen G; Schreiber, Martin A

    2011-04-01

    Rib fracture pain is notoriously difficult to manage. The lidocaine patch is effective in other pain scenarios with an excellent safety profile. This study assesses the efficacy of lidocaine patches for treating rib fracture pain. A prospectively gathered cohort of patients with rib fracture was retrospectively analyzed for use of lidocaine patches. Patients treated with lidocaine patches were matched to control subjects treated without patches. Subjective pain reports and narcotic use before and after patch placement, or equivalent time points for control subjects, were gathered from the chart. All patients underwent long-term follow-up, including a McGill Pain Questionnaire (MPQ). Twenty-nine patients with lidocaine patches (LP) and 29 matched control subjects (C) were analyzed. During the 24 hours before patch placement, pain scores and narcotic use were similar (LP 5.3, C 4.6, P = 0.19 and LP 51, C 32 mg morphine, P = 0.17). In the 24 hours after patch placement, LP patients had a greater decrease in pain scores (LP 1.2, C 0.0, P = 0.01) with no change in narcotic use (LP -8.4, C 0.5-mg change in morphine, P = 0.25). At 60 days, LP patients had a lower MPQ pain score (LP 7.7, C 12.2, P rib fracture pain. Lidocaine patches resulted in a sustained reduction in pain, outlasting the duration of therapy.

  4. Summary of experimental tests of elastomeric seismic isolation bearings for use in nuclear reactor plants

    International Nuclear Information System (INIS)

    Seidensticker, R.W.; Chang, Y.W.; Kulak, R.F.

    1992-01-01

    This paper describes an experimental test program for isolator bearings which was developed to help establish the viability of using laminated elastomer bearings for base isolation of nuclear reactor plants. The goal of the test program is to determine the performance characteristics of laminated seismic isolation bearings under a wide range of loadings. Tests were performed on scale-size laminated seismic isolators both within the design shear strain range to determine the response of the bearing under expected earthquake loading conditions, and beyond the design range to determine failure modes and to establish safety margins. Three types of bearings, each produced from a different manufacturer, have been tested: (1) high shape factor-high damping-high shear modulus bearings; (2) medium shape factor-high damping-high shear modulus bearings; and (3) medium shape factor-high damping-low shear modulus bearings. All of these tests described in this report were performed at the Earthquake Engineering Research Center at the University of California, Berkeley, with technical assistance from ANL. The tests performed on the three types of bearings have confirmed the high performance characteristics of the high damping-high and low shear modulus elastomeric bearings. The bearings have shown that they are capable of having extremely large shear strains before failure occurs. The most common failure mechanism was the debonding of the top steel plate from the isolators. This failure mechanism can be virtually eliminated by improved manufacturing quality control. The most important result of the failure test of the isolators is the fact that bearings can sustain large horizontal displacement, several times larger than the design value, with failure. Their performance in moderate and strong earthquakes will be far superior to conventional structures

  5. Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes

    Energy Technology Data Exchange (ETDEWEB)

    Mercado-Pagán, Ángel E.; Kang, Yunqing [Department of Orthopedic Surgery, Stanford University, Stanford, CA (United States); Findlay, Michael W. [Department of Plastic and Reconstructive Surgery, Stanford University, Stanford, CA (United States); University of Melbourne Department of Surgery, Royal Melbourne Hospital, Parkville, VIC (Australia); Yang, Yunzhi, E-mail: ypyang@stanford.edu [Department of Orthopedic Surgery, Stanford University, Stanford, CA (United States); Department of Materials Science and Engineering, Stanford University, Stanford, CA (United States)

    2015-04-01

    Engineering of small diameter (< 6 mm) vascular grafts (SDVGs) for clinical use remains a significant challenge. Here, elastomeric polyester urethane (PEU)-based hollow fiber membranes (HFMs) are presented as an SDVG candidate to target the limitations of current technologies and improve tissue engineering designs. HFMs are fabricated by a simple phase inversion method. HFM dimensions are tailored through adjustments to fabrication parameters. The walls of HFMs are highly porous. The HFMs are very elastic, with moduli ranging from 1–4 MPa, strengths from 1–5 MPa, and max strains from 300–500%. Permeability of the HFMs varies from 0.5–3.5 × 10{sup −6} cm/s, while burst pressure varies from 25 to 35 psi. The suture retention forces of HFMs are in the range of 0.8 to 1.2 N. These properties match those of blood vessels. A slow degradation profile is observed for all HFMs, with 71 to 78% of the original mass remaining after 8 weeks, providing a suitable profile for potential cellular incorporation and tissue replacement. Both human endothelial cells and human mesenchymal stem cells proliferate well in the presence of HFMs up to 7 days. These results demonstrate a promising customizable PEU HFMs for small diameter vascular repair and tissue engineering applications. - Highlights: • Hollow fiber membranes (HFMs) were fabricated and evaluated. • HFM properties could be tailored through adjustments to fabrication parameters. • Properties could match or exceed those of blood vessels. • HFM showed excellent compatibility in vitro. • HFMs have the potential to be used for small diameter vascular grafts.

  6. Linear dimensional changes in plaster die models using different elastomeric materials

    Directory of Open Access Journals (Sweden)

    Jefferson Ricardo Pereira

    2010-09-01

    Full Text Available Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05 and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm, mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm, polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm. All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.

  7. Effect of Microstructure Constraints on the Homogenized Elastic Constants of Elastomeric Sylgard/GMB Syntactic Foam.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Judith Alice [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Steck, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brown, Judith Alice [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Long, Kevin Nicholas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    Previous numerical studies of Sylgard filled with glass microballoons (GMB) have relied on various microstructure idealizations to achieve a large range of volume fractions with high mesh quality. This study investigates how different microstructure idealizations and constraints affect the apparent homogenized elastic constants in the virgin state of the material, in which all GMBs are intact and perfectly bonded to the Sylgard matrix, and in the fully damaged state of the material in which all GMBs are destroyed. In the latter state, the material behaves as an elastomeric foam. Four microstructure idealizations are considered relating to how GMBs are packed into a representative volume element (RVE): (1) no boundary penetration nor GMB-GMB overlap, (2) GMB-GMB overlap, (3) boundary penetration, and (4) boundary penetration and GMB-GMB overlap. First order computational homogenization with kinematically uniform displacement boundary conditions (KUBCs) was employed to determine the homogenized (apparent) bulk and shear moduli for the four microstructure idealizations in the intact and fully broken GMB material states. It was found that boundary penetration has a significant effect on the shear modulus for microstructures with intact GMBs, but that neither boundary penetration nor GMB overlap have a significant effect on homogenized properties for microstructures with fully broken GMBs. The primary conclusion of the study is that future investigations into Sylgard/GMB micromechanics should either force GMBs to stay within the RVE fully and/or use periodic BCs (PBCs) to eliminate the boundary penetration issues. The implementation of PBCs requires the improvement of existing tools in Sandia’s Sierra/SM code.

  8. Model calibration for a soft elastomeric capacitor sensor considering slippage under fatigue cracks

    Science.gov (United States)

    Kong, Xiangxiong; Li, Jian; Bennett, Caroline; Collins, William; Laflamme, Simon

    2016-04-01

    A newly-developed soft elastomeric capacitor (SEC) strain sensor has shown promise in fatigue crack monitoring. The SECs exhibit high levels of ductility and hence do not break under excessive strain when the substrate cracks due to slippage or de-bonding between the sensor and epoxy. The actual strain experienced by a SEC depends on the amount of slippage, which is difficult to simulate numerically, making it challenging to accurately predict the response of a SEC near a crack. In this paper, a two-step approach is proposed to simulate the capacitance response of a SEC. First, a finite element (FE) model of a steel compact tension specimen was analyzed under cyclic loading while the cracking process was simulated based on an element removal technique. Second, a rectangular boundary was defined near the crack region. The SEC outside the boundary was assumed to have perfect bond with the specimen, while that inside the boundary was assumed to deform freely due to slippage. A second FE model was then established to simulate the response of the SEC within the boundary subject to displacements at the boundary from the first FE model. The total simulated capacitance was computed from the model results by combining the computed capacitance inside and outside the boundary. The performance of the simulation incorporating slippage was evaluated by comparing the model results with the experimental data from the test performed on a compact tension specimen. The FE model considering slippage showed results that matched the experimental findings more closely than the FE model that did not consider slippage.

  9. Force decay evaluation of thermoplastic and thermoset elastomeric chains: A mechanical design comparison.

    Science.gov (United States)

    Masoud, Ahmed I; Tsay, T Peter; BeGole, Ellen; Bedran-Russo, Ana K

    2014-11-01

    To compare the following over a period of 8 weeks: (1) force decay between thermoplastic (TP) and thermoset (TS) elastomeric chains; (2) force decay between light (200-g) and heavy (350-g) initial forces; and (3) force decay between direct chains and chain loops (stretched from one pin around the second pin and back to the first pin). TP and TS chains were obtained from American Orthodontics™ (AOTP, AOTS) and ORMCO™ (OrTP, OrTS). Each of the four chain groups was subdivided into four subgroups with 10 specimens per subgroup: (1) direct chains light force, (2) direct chains heavy force, (3) chain loops light force, and (4) chain loops heavy force. The experiment was performed in artificial saliva (pH of 6.75) at 37°C. A significant difference was found between TP and TS chains, with an average mean difference of around 20% more force decay found in the TP chains (P < .001, α  =  .05). There was no significant difference between direct chains and chain loops except in OrTP, in which direct chains showed more force decay. There was also no significant difference in force decay identified when using light vs heavy forces. TS chains decayed less than TP chains, and chain loop retraction was beneficial only when using OrTP chains. Contrary to the interchangeable use of TP and TS chains in the published literature and in clinical practice, this study demonstrates that they perform differently under stress and that a clear distinction should be made between the two.

  10. Elastomeric Thermal Insulation Design Considerations in Long, Aluminized Solid Rocket Motors

    Science.gov (United States)

    Martin, Heath T.

    2017-01-01

    An all-new sounding rocket was designed at NASA's Marshall Space Flight Center that featured an aft finocyl, aluminized solid propellant grain and silica-filled ethylene-propylene-diene monomer (SFEPDM) internal insulation. Upon the initial static firing of the first of this new design, the solid rocket motor (SRM) case failed thermally just upstream of the aft closure early in the burn time. Subsequent fluid modeling indicated that the high-velocity combustion-product jets emanating from the fin-slots in the propellant grain were likely inducing a strongly swirling flow, thus substantially increasing the severity of the convective environment on the exposed portion of the SFEPDM insulation in this region. The aft portion of the fin-slots in another of the motors were filled with propellant to eliminate the possibility of both direct jet impingement on the exposed SFEPDM and the appearance of strongly swirling flow in the aft region of the motor. When static-fired, this motor's case still failed in the same axial location, and, though somewhat later than for the first static firing, still in less than 1/3rd of the desired burn duration. These results indicate that the extreme material decomposition rates of the SFEPDM in this application are not due to gas-phase convection or shear but rather to interactions with burning aluminum or alumina slag. Further comparisons with between SFEPDM performance in this design and that in other hot-fire tests provide insight into the mechanisms of SFEPDM decomposition in SRM aft domes that can guide the upcoming redesign effort, as well as other future SRM designs. These data also highlight the current limitations of modeling elastomeric insulators solely with diffusion-controlled, gas-phase thermochemistry in SRM regions with significant viscous shear and/or condense-phase impingement or flow.

  11. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    International Nuclear Information System (INIS)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Zenhausern, Frederic; Rivera, Andrew; Birdsell, Dawn N; Wagner, David M

    2015-01-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30–100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis. (paper)

  12. Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes

    International Nuclear Information System (INIS)

    Mercado-Pagán, Ángel E.; Kang, Yunqing; Findlay, Michael W.; Yang, Yunzhi

    2015-01-01

    Engineering of small diameter (< 6 mm) vascular grafts (SDVGs) for clinical use remains a significant challenge. Here, elastomeric polyester urethane (PEU)-based hollow fiber membranes (HFMs) are presented as an SDVG candidate to target the limitations of current technologies and improve tissue engineering designs. HFMs are fabricated by a simple phase inversion method. HFM dimensions are tailored through adjustments to fabrication parameters. The walls of HFMs are highly porous. The HFMs are very elastic, with moduli ranging from 1–4 MPa, strengths from 1–5 MPa, and max strains from 300–500%. Permeability of the HFMs varies from 0.5–3.5 × 10 −6 cm/s, while burst pressure varies from 25 to 35 psi. The suture retention forces of HFMs are in the range of 0.8 to 1.2 N. These properties match those of blood vessels. A slow degradation profile is observed for all HFMs, with 71 to 78% of the original mass remaining after 8 weeks, providing a suitable profile for potential cellular incorporation and tissue replacement. Both human endothelial cells and human mesenchymal stem cells proliferate well in the presence of HFMs up to 7 days. These results demonstrate a promising customizable PEU HFMs for small diameter vascular repair and tissue engineering applications. - Highlights: • Hollow fiber membranes (HFMs) were fabricated and evaluated. • HFM properties could be tailored through adjustments to fabrication parameters. • Properties could match or exceed those of blood vessels. • HFM showed excellent compatibility in vitro. • HFMs have the potential to be used for small diameter vascular grafts

  13. The thermal and mechanical properties of a low-density glass-fiber-reinforced elastomeric ablation material

    Science.gov (United States)

    Engelke, W. T.; Robertson, R. W.; Bush, A. L.; Pears, C. D.

    1974-01-01

    An evaluation of the thermal and mechanical properties was performed on a molded low-density elastomeric ablation material designated as Material B. Both the virgin and charred states were examined to provide meaningful inputs to the design of a thermal protection system. Chars representative of the flight chars formed during ablation were prepared in a laboratory furnace from 600 K to 1700 K and properties of effective thermal conductivity, heat capacity, porosity and permeability were determined on the furnace chars formed at various temperature levels within the range. This provided a boxing of the data which will enable the prediction of the transient response of the material during flight ablation.

  14. Bright patches on chernozems - from space to surface and soil properties

    Science.gov (United States)

    Smetanova, Anna; Burian, Libor; Holec, Juraj; Minár, Jozef

    2016-04-01

    The bright patches on chernozems can be easily visually distinguished in the aerial images, due to their bright colour contrasting with the dark colour of the surrounding chernozems. They present a typical feature of the loess hilly lands in the Danube Lowland. They reffer predominantely to the areas where (i) the soil substrate - loess is tilled, (ii) the transitional AC horizon of chernozems is tilled, (iii) or one of them, or both are mixed into the plough layer during tillage. They are usually categorized as eroded chernozems or regosols. To the lower extent, the accumulation patches might occur, if the loess material redeposited from upper part of the slope in the colluvium is tilled. This study focuses on uncovering the soil properties of bright patches, identified on different scales - spatial and temporal, combining three methods - the remote sensing, morphometric analysis and soil mapping. In the area of 31 km² (located in the Trnavska pahorkatina Hilly Land, south of Trnava), the bright patches were identified using visual analysis of georeferenced aerial images from 1949 and 2004, representing two types of landscape structure characteristic for the 20th Century. In 1949 small, in one direction elongated fields, with mean size 0.008 km2 prevailed, while in 2004 the mean size of a field was 0.28 km2. The morphometric analysis was performed based on DEM derived from topographical maps (scale 1:10 000). Soil sampling in the first phase of the project was performed in a subset of the patches in small agriculture catchment (0.28 km2), situated in one single field (in 2004). The percussion drilling or hand augering (with undisturbed structure) were used in order to describe the depth of the soil horizons and the soil properties. Together 365 bright patches covering 3.2% of the study area (31 km²) were identified in 1949; while it was twice more in 2004 (776 patches), when they covered approximately 12% of the same area. The bright patches were predominantly

  15. Patch size has no effect on insect visitation rate per unit area in garden-scale flower patches

    Science.gov (United States)

    Garbuzov, Mihail; Madsen, Andy; Ratnieks, Francis L. W.

    2015-01-01

    Previous studies investigating the effect of flower patch size on insect flower visitation rate have compared relatively large patches (10-1000s m2) and have generally found a negative relationship per unit area or per flower. Here, we investigate the effects of patch size on insect visitation in patches of smaller area (range c. 0.1-3.1 m2), which are of particular relevance to ornamental flower beds in parks and gardens. We studied two common garden plant species in full bloom with 6 patch sizes each: borage (Borago officinalis) and lavender (Lavandula × intermedia 'Grosso'). We quantified flower visitation by insects by making repeated counts of the insects foraging at each patch. On borage, all insects were honey bees (Apis mellifera, n = 5506 counts). On lavender, insects (n = 737 counts) were bumble bees (Bombus spp., 76.9%), flies (Diptera, 22.4%), and butterflies (Lepidoptera, 0.7%). On both plant species we found positive linear effects of patch size on insect numbers. However, there was no effect of patch size on the number of insects per unit area or per flower and, on lavender, for all insects combined or only bumble bees. The results show that it is possible to make unbiased comparisons of the attractiveness of plant species or varieties to flower-visiting insects using patches of different size within the small scale range studied and make possible projects aimed at comparing ornamental plant varieties using existing garden flower patches of variable area.

  16. Patching DFT, T-duality and gerbes

    Energy Technology Data Exchange (ETDEWEB)

    Howe, P.S.; Papadopoulos, G. [Department of Mathematics, King’s College London,Strand, London WC2R 2LS (United Kingdom)

    2017-04-12

    We clarify the role of the dual coordinates as described from the perspectives of the Buscher T-duality rules and Double Field Theory. We show that the T-duality angular dual coordinates cannot be identified with Double Field Theory dual coordinates in any of the proposals that have been made in the literature for patching the doubled spaces. In particular, we show with explicit examples that the T-duality angular dual coordinates can have non-trivial transition functions over a spacetime and that their identification with the Double Field Theory dual coordinates is in conflict with proposals in which the latter remain inert under the patching of the B-field. We then demonstrate that the Double Field Theory coordinates can be identified with some C-space coordinates and that the T-dual spaces of a spacetime are subspaces of the gerbe in C-space. The construction provides a description of both the local O(d,d) symmetry and the T-dual spaces of spacetime.

  17. Patching DFT, T-duality and gerbes

    International Nuclear Information System (INIS)

    Howe, P.S.; Papadopoulos, G.

    2017-01-01

    We clarify the role of the dual coordinates as described from the perspectives of the Buscher T-duality rules and Double Field Theory. We show that the T-duality angular dual coordinates cannot be identified with Double Field Theory dual coordinates in any of the proposals that have been made in the literature for patching the doubled spaces. In particular, we show with explicit examples that the T-duality angular dual coordinates can have non-trivial transition functions over a spacetime and that their identification with the Double Field Theory dual coordinates is in conflict with proposals in which the latter remain inert under the patching of the B-field. We then demonstrate that the Double Field Theory coordinates can be identified with some C-space coordinates and that the T-dual spaces of a spacetime are subspaces of the gerbe in C-space. The construction provides a description of both the local O(d,d) symmetry and the T-dual spaces of spacetime.

  18. Influence of habitat quality, population size, patch size, and connectivity on patch-occupancy dynamics of the middle spotted woodpecker.

    Science.gov (United States)

    Robles, Hugo; Ciudad, Carlos

    2012-04-01

    Despite extensive research on the effects of habitat fragmentation, the ecological mechanisms underlying colonization and extinction processes are poorly known, but knowledge of these mechanisms is essential to understanding the distribution and persistence of populations in fragmented habitats. We examined these mechanisms through multiseason occupancy models that elucidated patch-occupancy dynamics of Middle Spotted Woodpeckers (Dendrocopos medius) in northwestern Spain. The number of occupied patches was relatively stable from 2000 to 2010 (15-24% of 101 patches occupied every year) because extinction was balanced by recolonization. Larger and higher quality patches (i.e., higher density of oaks >37 cm dbh [diameter at breast height]) were more likely to be occupied. Habitat quality (i.e., density of large oaks) explained more variation in patch colonization and extinction than did patch size and connectivity, which were both weakly associated with probabilities of turnover. Patches of higher quality were more likely to be colonized than patches of lower quality. Populations in high-quality patches were less likely to become extinct. In addition, extinction in a patch was strongly associated with local population size but not with patch size, which means the latter may not be a good surrogate of population size in assessments of extinction probability. Our results suggest that habitat quality may be a primary driver of patch-occupancy dynamics and may increase the accuracy of models of population survival. We encourage comparisons of competing models that assess occupancy, colonization, and extinction probabilities in a single analytical framework (e.g., dynamic occupancy models) so as to shed light on the association of habitat quality and patch geometry with colonization and extinction processes in different settings and species. ©2012 Society for Conservation Biology.

  19. FuncPatch: a web server for the fast Bayesian inference of conserved functional patches in protein 3D structures.

    Science.gov (United States)

    Huang, Yi-Fei; Golding, G Brian

    2015-02-15

    A number of statistical phylogenetic methods have been developed to infer conserved functional sites or regions in proteins. Many methods, e.g. Rate4Site, apply the standard phylogenetic models to infer site-specific substitution rates and totally ignore the spatial correlation of substitution rates in protein tertiary structures, which may reduce their power to identify conserved functional patches in protein tertiary structures when the sequences used in the analysis are highly similar. The 3D sliding window method has been proposed to infer conserved functional patches in protein tertiary structures, but the window size, which reflects the strength of the spatial correlation, must be predefined and is not inferred from data. We recently developed GP4Rate to solve these problems under the Bayesian framework. Unfortunately, GP4Rate is computationally slow. Here, we present an intuitive web server, FuncPatch, to perform a fast approximate Bayesian inference of conserved functional patches in protein tertiary structures. Both simulations and four case studies based on empirical data suggest that FuncPatch is a good approximation to GP4Rate. However, FuncPatch is orders of magnitudes faster than GP4Rate. In addition, simulations suggest that FuncPatch is potentially a useful tool complementary to Rate4Site, but the 3D sliding window method is less powerful than FuncPatch and Rate4Site. The functional patches predicted by FuncPatch in the four case studies are supported by experimental evidence, which corroborates the usefulness of FuncPatch. The software FuncPatch is freely available at the web site, http://info.mcmaster.ca/yifei/FuncPatch golding@mcmaster.ca Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Improving Saliency Models by Predicting Human Fixation Patches

    KAUST Repository

    Dubey, Rachit

    2015-04-16

    There is growing interest in studying the Human Visual System (HVS) to supplement and improve the performance of computer vision tasks. A major challenge for current visual saliency models is predicting saliency in cluttered scenes (i.e. high false positive rate). In this paper, we propose a fixation patch detector that predicts image patches that contain human fixations with high probability. Our proposed model detects sparse fixation patches with an accuracy of 84 % and eliminates non-fixation patches with an accuracy of 84 % demonstrating that low-level image features can indeed be used to short-list and identify human fixation patches. We then show how these detected fixation patches can be used as saliency priors for popular saliency models, thus, reducing false positives while maintaining true positives. Extensive experimental results show that our proposed approach allows state-of-the-art saliency methods to achieve better prediction performance on benchmark datasets.

  1. Improving Saliency Models by Predicting Human Fixation Patches

    KAUST Repository

    Dubey, Rachit; Dave, Akshat; Ghanem, Bernard

    2015-01-01

    There is growing interest in studying the Human Visual System (HVS) to supplement and improve the performance of computer vision tasks. A major challenge for current visual saliency models is predicting saliency in cluttered scenes (i.e. high false positive rate). In this paper, we propose a fixation patch detector that predicts image patches that contain human fixations with high probability. Our proposed model detects sparse fixation patches with an accuracy of 84 % and eliminates non-fixation patches with an accuracy of 84 % demonstrating that low-level image features can indeed be used to short-list and identify human fixation patches. We then show how these detected fixation patches can be used as saliency priors for popular saliency models, thus, reducing false positives while maintaining true positives. Extensive experimental results show that our proposed approach allows state-of-the-art saliency methods to achieve better prediction performance on benchmark datasets.

  2. Circularly Polarized Slotted Microstrip Patch Antenna with Finite Ground Plane

    Directory of Open Access Journals (Sweden)

    Sanyog Rawat

    2012-12-01

    Full Text Available In this paper a new geometry of circularly polarized patch antenna is proposed with improved bandwidth. The radiation performance of proposed patch antenna is investigated using IE3D simulation software and its performance is compared with that of conventional rectangular patch antenna. The simulated return loss, axial ratio and impedance with frequency for the proposed antenna are reported in this paper. It is shown that by selecting suitable ground-plane dimensions, air gap and location of the slots, the impedance bandwidth can be enhanced upto 10.15% as compared to conventional rectangular patch (4.24% with an axial ratio bandwidth of 4.05%.

  3. Composite GPS Patch Antenna for the AR Bandwidth Enhancement

    Directory of Open Access Journals (Sweden)

    Minkil Park

    2016-01-01

    Full Text Available A composite Global Positioning System (GPS patch antenna with a quadrature 3 dB hybrid coupler was designed and implemented for working RHCP and had a broadband axial ratio (AR bandwidth. We designed two patches as a FR-4 patch and 1.5 mm thickness thin ceramic patch with a quadrature 3 dB hybrid coupler. A CP radiation pattern was achieved, and the AR bandwidth improved by incorporating a quadrature 3 dB hybrid coupler feed structure in a micro-strip patch antenna. SMD by chip elements was applied to the quadrature 3 dB hybrid coupler. For the composite FR-4 and ceramic patch antennas, the VSWR measurement showed a 2 : 1 ratio over the entire design band, and the 3 dB AR bandwidth was 295 and 580 MHz for the FR-4 patch and ceramic patch antennas, respectively. The antenna gains for the composite FR-4 and ceramic patch antennas were measured as 1.36–2.75 and 1.47–2.71 dBi with 15.11–25.3% and 19.25–28.45% efficiency, respectively.

  4. Patch Type Granuloma Annulare Imitating Cutaneous T-Cell Lymphoma

    Directory of Open Access Journals (Sweden)

    Şeval Doğruk Kaçar

    2015-03-01

    Full Text Available Granuloma annulare (GA is a benign inflammatory skin disease with distinct clinical and histopathological findings. Patch type GA is described with erythematous patches beyond the classical clinical appearance and an interstitial pattern is observed without histopathologically granulomas with disseminated histiocytes among collagen bundles and vessels. Here we report 46 year old woman diagnosed as patch type GA after a punch biopsy performed from the annular bordered patches in belly area, which is a classical area for mycosis fungoides (MF evolution, and lesions increasingly spreading out within a 2 year period.

  5. Laparoscopic repair of perforated peptic ulcer: patch versus simple closure.

    Science.gov (United States)

    Abd Ellatif, M E; Salama, A F; Elezaby, A F; El-Kaffas, H F; Hassan, A; Magdy, A; Abdallah, E; El-Morsy, G

    2013-01-01

    Laparoscopic correction of perforated peptic ulcer (PPU) has become an accepted way of management. Patch omentoplasty stayed for decades the main method of repair. The goal of the present study was to evaluate whether laparoscopic simple repair of PPU is as safe as patch omentoplasty. Since June 2005, 179 consecutive patients of PPU were treated by laparoscopic repair at our centers. We conducted a retrospective chart review in December 2012. Group I (patch group) included patients who were treated with standard patch omentoplasty. Group II (non-patch group) included patients who received simple repair without patch. From June 2007 to Dec. 2012, 179 consecutive patients of PPU who were treated by laparoscopic repair at our centers were enrolled in this multi-center retrospective study. 108 patients belong to patch group. While 71 patients were treated with laparoscopic simple repair. Operative time was significantly shorter in group II (non patch) (p = 0.01). No patient was converted to laparotomy. There was no difference in age, gender, ASA score, surgical risk (Boey's) score, and incidence of co-morbidities. Both groups were comparable in terms of hospital stay, time to resume oral intake, postoperative complications and surgical outcomes. Laparoscopic simple repair of PPU is a safe procedure compared with the traditional patch omentoplasty in presence of certain selection criteria. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  6. Quantitative Analysis of Range Image Patches by NEB Method

    Directory of Open Access Journals (Sweden)

    Wang Wen

    2017-01-01

    Full Text Available In this paper we analyze sampled high dimensional data with the NEB method from a range image database. Select a large random sample of log-valued, high contrast, normalized, 8×8 range image patches from the Brown database. We make a density estimator and we establish 1-dimensional cell complexes from the range image patch data. We find topological properties of 8×8 range image patches, prove that there exist two types of subsets of 8×8 range image patches modelled as a circle.

  7. Dry patch formed boiling and burnout in potassium pool boiling

    International Nuclear Information System (INIS)

    Michiyoshi, I.; Takenaka, N.; Takahashi, O.

    1986-01-01

    Experimental results are presented on dry patch formed boiling and burnout in saturated potassium pool boiling on a horizontal plane heater for system pressures from 30 to 760 torr and liquid levels from 5 to 50 mm. The dry patch formation occurs in the intermittent boiling which is often encountered when liquid alkali metals are used under relatively low pressure conditions. Burnout is caused from both continuous nucleate and dry patch formed boiling. The burnout heat flux together with nucleate boiling heat transfer coefficients are empirically correlated with system pressures. A model is also proposed to predict the minimum heat flux to form the dry patch. (author)

  8. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave, and Chemical Disinfection.

    Science.gov (United States)

    Kamble, Suresh S; Khandeparker, Rakshit Vijay; Somasundaram, P; Raghav, Shweta; Babaji, Rashmi P; Varghese, T Joju

    2015-09-01

    Impression materials during impression procedure often get infected with various infectious diseases. Hence, disinfection of impression materials with various disinfectants is advised to protect the dental team. Disinfection can alter the dimensional accuracy of impression materials. The present study was aimed to evaluate the dimensional accuracy of elastomeric impression materials when treated with different disinfectants; autoclave, chemical, and microwave method. The impression materials used for the study were, dentsply aquasil (addition silicone polyvinylsiloxane syringe and putty), zetaplus (condensation silicone putty and light body), and impregum penta soft (polyether). All impressions were made according to manufacturer's instructions. Dimensional changes were measured before and after different disinfection procedures. Dentsply aquasil showed smallest dimensional change (-0.0046%) and impregum penta soft highest linear dimensional changes (-0.026%). All the tested elastomeric impression materials showed some degree of dimensional changes. The present study showed that all the disinfection procedures produce minor dimensional changes of impression material. However, it was within American Dental Association specification. Hence, steam autoclaving and microwave method can be used as an alternative method to chemical sterilization as an effective method.

  9. Elastomeric Structural Attachment Concepts for Aircraft Flap Noise Reduction - Challenges and Approaches to Hyperelastic Structural Modeling and Analysis

    Science.gov (United States)

    Sreekantamurthy, Thammaiah; Turner, Travis L.; Moore, James B.; Su, Ji

    2014-01-01

    Airframe noise is a significant part of the overall noise of transport aircraft during the approach and landing phases of flight. Airframe noise reduction is currently emphasized under the Environmentally Responsible Aviation (ERA) and Fixed Wing (FW) Project goals of NASA. A promising concept for trailing-edge-flap noise reduction is a flexible structural element or link that connects the side edges of the deployable flap to the adjacent main-wing structure. The proposed solution is distinguished by minimization of the span-wise extent of the structural link, thereby minimizing the aerodynamic load on the link structure at the expense of increased deformation requirement. Development of such a flexible structural link necessitated application of hyperelastic materials, atypical structural configurations and novel interface hardware. The resulting highly-deformable structural concept was termed the FLEXible Side Edge Link (FLEXSEL) concept. Prediction of atypical elastomeric deformation responses from detailed structural analysis was essential for evaluating feasible concepts that met the design constraints. The focus of this paper is to describe the many challenges encountered with hyperelastic finite element modeling and the nonlinear structural analysis of evolving FLEXSEL concepts. Detailed herein is the nonlinear analysis of FLEXSEL concepts that emerged during the project which include solid-section, foamcore, hollow, extended-span and pre-stressed concepts. Coupon-level analysis performed on elastomeric interface joints, which form a part of the FLEXSEL topology development, are also presented.

  10. The Effect of Herbal Mouthwashes on the Force Decay of Elastomeric Chains: An In-vitro Study

    Directory of Open Access Journals (Sweden)

    Mohammed Nahidh

    2017-10-01

    Full Text Available Background: This in vitro study aimed to evaluate the effect of four herbal mouthwashes on the force decay of two types of clear short elastomeric chains (Regular and Extreme at various time intervals. Materials and methods: Four hundred forty pieces of both types of elastomeric chains with 19 mm length were utilized in this study. The force was measured, using digital scale immediately, after one-day immersion in distilled water and after 1, 2, 3 and 4 weeks immersion in the specific mouthwash for one minute twice daily then washed and kept in distilled water at 37°C. Force decay was calculated and compared among different elastic types, mouthwashes and time intervals using t-test and one-way ANOVA then Tukey’s tests. Results: The force degradation of regular type was significantly higher than extreme one. With time, the force decay increased significantly in both types. There was non-significant difference among the mouthwashes in the first and second weeks while the opposite in the third and fourth especially with the control group. Conclusions: The extreme type is preferred over the regular one because of its low force decay and the tested mouthwashes have no clinical significant effect on the force degradation over time in comparison with distilled water.

  11. Low-level laser therapy effects on pain perception related to the use of orthodontic elastomeric separators

    Directory of Open Access Journals (Sweden)

    Rachel D'Aurea Furquim

    2015-06-01

    Full Text Available INTRODUCTION: Some patients refer to pre-banding orthodontic separation as a painful orthodontic procedure. Low-level laser therapy (LLLT has been reported to have local analgesic effect. OBJECTIVE: The aim of this single-blind study was to investigate the perception of pain caused by orthodontic elastomeric separators with and without a single LLLT application (6J. METHODS: The sample comprised 79 individuals aged between 13 and 34 years old at orthodontic treatment onset. Elastomeric separators were placed in first maxillary molars at mesial and distal surfaces and kept in place for three days. The volunteers scored pain intensity on a visual analogue scale (VAS after 6 and 12 hours, and after the first, second and third days. One third of patients received laser applications, whereas another third received placebo applications and the remaining ones were controls. Applications were performed in a split-mouth design. Thus, three groups (laser, placebo and control were assessed. RESULTS: No differences were found among groups considering pain perception in all periods observed. CONCLUSION: The use of a single-dose of LLLT did not cause significant reduction in orthodontic pain perception. Overall pain perception due to orthodontic separator placement varied widely and was usually mild.

  12. Models for Patch-Based Image Restoration

    Directory of Open Access Journals (Sweden)

    Petrovic Nemanja

    2009-01-01

    Full Text Available Abstract We present a supervised learning approach for object-category specific restoration, recognition, and segmentation of images which are blurred using an unknown kernel. The novelty of this work is a multilayer graphical model which unifies the low-level vision task of restoration and the high-level vision task of recognition in a cooperative framework. The graphical model is an interconnected two-layer Markov random field. The restoration layer accounts for the compatibility between sharp and blurred images and models the association between adjacent patches in the sharp image. The recognition layer encodes the entity class and its location in the underlying scene. The potentials are represented using nonparametric kernel densities and are learnt from training data. Inference is performed using nonparametric belief propagation. Experiments demonstrate the effectiveness of our model for the restoration and recognition of blurred license plates as well as face images.

  13. Models for Patch-Based Image Restoration

    Directory of Open Access Journals (Sweden)

    Mithun Das Gupta

    2009-01-01

    Full Text Available We present a supervised learning approach for object-category specific restoration, recognition, and segmentation of images which are blurred using an unknown kernel. The novelty of this work is a multilayer graphical model which unifies the low-level vision task of restoration and the high-level vision task of recognition in a cooperative framework. The graphical model is an interconnected two-layer Markov random field. The restoration layer accounts for the compatibility between sharp and blurred images and models the association between adjacent patches in the sharp image. The recognition layer encodes the entity class and its location in the underlying scene. The potentials are represented using nonparametric kernel densities and are learnt from training data. Inference is performed using nonparametric belief propagation. Experiments demonstrate the effectiveness of our model for the restoration and recognition of blurred license plates as well as face images.

  14. Dissolving Microneedle Patches for Dermal Vaccination.

    Science.gov (United States)

    Leone, M; Mönkäre, J; Bouwstra, J A; Kersten, G

    2017-11-01

    The dermal route is an attractive route for vaccine delivery due to the easy skin accessibility and a dense network of immune cells in the skin. The development of microneedles is crucial to take advantage of the skin immunization and simultaneously to overcome problems related to vaccination by conventional needles (e.g. pain, needle-stick injuries or needle re-use). This review focuses on dissolving microneedles that after penetration into the skin dissolve releasing the encapsulated antigen. The microneedle patch fabrication techniques and their challenges are discussed as well as the microneedle characterization methods and antigen stability aspects. The immunogenicity of antigens formulated in dissolving microneedles are addressed. Finally, the early clinical development is discussed.

  15. Microwave response of hole and patch arrays

    Science.gov (United States)

    Taylor, Melita C.; Edmunds, James D.; Hendry, Euan; Hibbins, Alastair P.; Sambles, J. Roy

    2010-10-01

    The electromagnetic response of two-dimensional square arrays of perfectly conducting square patches, and their complementary structures, is modeled utilizing a modal matching technique and employing Babinet’s principle. This method allows for the introduction of progressively higher diffracted orders and waveguide modes to be included in the calculation, hence aiding understanding of the underlying causal mechanism for the observed response. At frequencies close to, but below, the onset of diffraction, a near-complete reflection condition is predicted, even for low filling fractions: conversely, for high filling fractions a near-complete transmission condition results. These resonance phenomena are associated with evanescent diffraction, which is sufficiently strong to reverse the step change in transmission upon establishment of electrical continuity; i.e., the connected structure demonstrates increased transmission with increasing filling fraction.

  16. Patch testing in Australia: Is it adequate?

    Science.gov (United States)

    Tizi, Stephanie; Nixon, Rosemary L

    2016-08-01

    Patch testing (PT) is essential for making the diagnosis of allergic contact dermatitis (ACD). However, the extent of PT undertaken by Australian dermatologists is unknown. The objectives of this study were to determine the rate and type of PT in Australia, the perceived obstacles to PT, and to explore the exposure to PT in dermatology training. Data were collected on private PT (analysing Medicare item numbers) and public hospital-based PT (estimated via verbal reports). An online survey on PT was sent to Fellows of the Australasian College of Dermatologists. It was found that total PT numbers, combining Medicare item number and public hospital data, were below the suggested optimum in all states and in Australia overall. Of the 173 respondents to the survey, 61% reported they patch tested and 78% reported they referred for PT. TrueTest was the most commonly used PT system, although it is known to be inadequate. Dermatologists who PT as registrars were significantly more likely to PT as consultants (P value = 0.0029). Cost, expertise required and staffing were considered major obstacles to performing PT. Accessibility and cost to the patient were common obstacles to referral. The combination of suboptimal PT rates and inadequate PT means that patients are missing out on being diagnosed with ACD in Australia. Increasing the exposure of registrars to PT, supporting specialised centres, the development of the Australian Baseline Series and the Contact Allergen Bank will, it is hoped, improve the rates of comprehensive PT in Australia. © 2015 The Australasian College of Dermatologists.

  17. An electrospun polydioxanone patch for the localisation of biological therapies during tendon repair

    Directory of Open Access Journals (Sweden)

    O Hakimi

    2012-10-01

    Full Text Available Rotator cuff tendon pathology is thought to account for 30-70 % of all shoulder pain. For cases that have failed conservative treatment, surgical re-attachment of the tendon to the bone with a non-absorbable suture is a common option. However, the failure rate of these repairs is high, estimated at up to 75 %. Studies have shown that in late disease stages the tendon itself is extremely degenerate, with reduced cell numbers and poor matrix organisation. Thus, it has been suggested that adding biological factors such as platelet rich plasma (PRP and mesenchymal stem cells could improve healing. However, the articular capsule of the glenohumeral joint and the subacromial bursa are large spaces, and injecting beneficial factors into these sites does not ensure localisation to the area of tendon damage.Thus, the aim of this study was to develop a biocompatible patch for improving the healing rates of rotator cuff repairs. The patch will create a confinement around the repair area and will be used to guide injections to the vicinity of the surgical repair.Here, we characterised and tested a preliminary prototype of the patch utilising in vitro tools and primary tendon-derived cells, showing exceptional biocompatibility despite rapid degradation, improved cell attachment and that cells could migrate across the patch towards a chemo-attractant. Finally, we showed the feasibility of detecting the patch using ultrasound and injecting liquid into the confinement ex vivo. There is a potential for using this scaffold in the surgical repair of interfaces such as the tendon insertion in the rotator cuff, in conjunction with beneficial factors.

  18. Plaque retention by self-ligating vs elastomeric orthodontic brackets: quantitative comparison of oral bacteria and detection with adenosine triphosphate-driven bioluminescence.

    NARCIS (Netherlands)

    Pellegrini, P.; Sauerwein, R.W.; Finlayson, T.; McLeod, J.; Covell, D.A.; Maier, T.; Machida, C.A.

    2009-01-01

    INTRODUCTION: Enamel decalcification is a common problem in orthodontics. The objectives of this randomized clinical study were to enumerate and compare plaque bacteria surrounding 2 bracket types, self-ligating (SL) vs elastomeric ligating (E), and to determine whether adenosine triphosphate

  19. Sixteen-week analysis of unaltered elastomeric chain relating in-vitro force degradation with in-vivo extraction space tooth movement.

    Science.gov (United States)

    Evans, Kristin S; Wood, Cory M; Moffitt, Allen H; Colgan, John A; Holman, J Kevin; Marshall, Steven D; Pope, D Spencer; Sample, Lew B; Sherman, Stephen L; Sinclair, Peter M; Trulove, Tim S

    2017-04-01

    The purposes of this study were to evaluate whether unaltered elastomeric chain can continue to move teeth for 16 weeks and to relate it to the amount of force remaining for the same batch of elastomeric chains. The in-vivo portion of the study had a sample of 30 paired extraction space sites from 22 subjects who were measured for closure of the space every 28 days. The altered side elastomeric chain served as the control and was replaced at 28-day intervals whereas the experimental side remained unaltered. In the in-vitro portion of the study, 100 each of 2-unit and 3-unit segments of the same batch of elastomeric chains were placed in a water bath, and the force was measured for 20 of each segment length at the 28-day measurement points. Statistically significant amounts of space closure occurred at both the altered and unaltered sites at all measurement time points. The mean space closure at the altered sites was minimally greater than that observed at the paired unaltered sites. The mean differences of space closure between the altered and unaltered sites ranged from a minimum of -0.05 mm at 4 weeks to a maximum of -0.14 mm at 8 weeks. The elastomeric chain force degraded rapidly by 4 weeks but continued a gradual diminution of force to 86 g at 16 weeks. Unaltered elastomeric chain continued to move teeth into extraction spaces for 16 weeks in this sample from both statistically and clinically significant standpoints. There were minimal and statistically insignificant differences in the mean space closure measurements between the paired altered and unaltered sites. The elastomeric chain force at 16 weeks was less than 100 g, yet at the same time point, teeth continued to move clinically. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  20. Treating voxel geometries in radiation protection dosimetry with a patched version of the Monte Carlo codes MCNP and MCNPX.

    Science.gov (United States)

    Burn, K W; Daffara, C; Gualdrini, G; Pierantoni, M; Ferrari, P

    2007-01-01

    The question of Monte Carlo simulation of radiation transport in voxel geometries is addressed. Patched versions of the MCNP and MCNPX codes are developed aimed at transporting radiation both in the standard geometry mode and in the voxel geometry treatment. The patched code reads an unformatted FORTRAN file derived from DICOM format data and uses special subroutines to handle voxel-to-voxel radiation transport. The various phases of the development of the methodology are discussed together with the new input options. Examples are given of employment of the code in internal and external dosimetry and comparisons with results from other groups are reported.

  1. Results of patch testing in 10 patients with peristomal dermatitis.

    Science.gov (United States)

    Landis, Megan N; Keeling, James H; Yiannias, James A; Richardson, Donna M; Nordberg Linehan, Diane L; Davis, Mark D P

    2012-09-01

    Peristomal dermatitis is a common problem in patients with ostomies that is a source of considerable morbidity. Irritant contact dermatitis is most common, but allergic contact dermatitis can also occur. Because of the lack of published reports on patch testing for this indication, we undertook a retrospective study of patch testing results in patients with suspected peristomal allergic contact dermatitis. We sought to describe our patch testing experience with patients referred with peristomal dermatitis. This was a retrospective review of medical records of patients with ostomies and peristomal dermatitis who underwent patch testing in the Mayo Clinic Departments of Dermatology in Jacksonville, FL; Rochester, MN; and Scottsdale, AZ, during a 10-year period (2000-2010). Ten patients with peristomal dermatitis were referred for patch testing (6 in Minnesota, 2 in Florida, and 2 in Arizona). Patients were patch tested to the materials used in their stoma devices, to the standard series, and in some cases to supplemental series. All 10 had at least one allergic patch test reaction, most commonly to stoma paste (3 of 10 patients). Retrospective nature of study via chart review is a limitation. Patch testing is a useful tool for identification of allergens in patients with peristomal dermatitis. Copyright © 2011 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  2. FDTD Analysis of U-Slot Rectangular Patch Antenna

    Science.gov (United States)

    Luk, K. M.; Tong, K. F.; Shum, S. M.; Lee, K. F.; Lee, R. Q.

    1997-01-01

    The U-slot rectangular patch antenna (Figure I) has been found experimentally to provide impedance and gain bandwidths of about 300 without the need of stacked or coplanar parasitic elements [1,2]. In this paper, simulation results of the U-slot patch using FDTD analysis are presented. Comparison with measured results are given.

  3. Pharmacokinetic Evaluation of Two Nicotine Patches in Smokers.

    Science.gov (United States)

    Rasmussen, Scott; Horkan, Kathleen Halabuk; Kotler, Mitchell

    2018-02-02

    Smoking continues to be a major preventable cause of early mortality worldwide, and nicotine replacement therapy has been demonstrated to increase rates of abstinence among smokers attempting to quit. Nicotine transdermal systems (also known as nicotine patches) attach to the skin via an adhesive layer composed of a mixture of different-molecular-weight polyisobutylenes (PIBs) in a specific ratio. This randomized, single-dose, 2-treatment, crossover pharmacokinetic (PK) trial assessed the bioequivalence of nicotine patches including a replacement PIB adhesive (test) compared with the PIB adhesive historically used on marketed patches (reference). The test and reference patches were bioequivalent, as determined by the PK parameters of C max and AUC 0-t . In addition, the parameters T max and t 1/2 did not significantly differ between the 2 patches, supporting the bioequivalence finding from the primary analysis. The tolerability profiles of the patches containing the replacement and previously used PIB adhesives were similar; application-site adverse events did not significantly differ between test and reference patches. Overall, these data establish the bioequivalence of the nicotine patch with the replacement PIB adhesive formulation and the previously utilized PIB adhesive formulation. © 2018 The Authors. Clinical Pharmacology in Drug Development published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.

  4. Rabies vaccination in dogs using a dissolving microneedle patch.

    Science.gov (United States)

    Arya, Jaya M; Dewitt, Kristopher; Scott-Garrard, Maya; Chiang, Yu-Wei; Prausnitz, Mark R

    2016-10-10

    Because humans get rabies primarily through dog bites, stray dog population control and mass or mandatory vaccination of domestic dogs and other animals has virtually eliminated human rabies in industrialized countries. However, thousands of people in developing countries die of rabies each year due to the inability to control dog populations and implement mass vaccination because of financial, logistical and other challenges. The availability of an easier-to-administer and more cost-effective vaccine may help to address some of these issues. Here, we propose the use of dissolving microneedle patches for simple and potentially cost-effective rabies vaccination, and assess the safety and immunogenicity of microneedle patch vaccination using a rabies DNA vaccine in dogs. The vaccine was stable upon formulation and storage for at least 3weeks at 4°C in a microneedle patch. For vaccination, the patches were applied to the inner ear by hand without an applicator. Microneedle patches were well tolerated in the skin, with mild erythema, minimal wheal formation and complete resolution of skin reactions within 7days, and generated no systemic adverse events. Microneedle patches were at least as immunogenic as intramuscular injection at the same dose, as demonstrated by similar serum neutralizing antibody titers. A ten-fold lower vaccine dose administered by microneedle patch generated a weaker immune response compared to full-dose intramuscular vaccination. We conclude that dissolving microneedle patches may provide an innovative approach to mass vaccination of dogs. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Phosphorus leaching from cow manure patches on soil columns

    NARCIS (Netherlands)

    Chardon, W.J.; Aalderink, G.H.; Salm, van der C.

    2007-01-01

    The loss of P in overland flow or leachate from manure patches can impair surface water quality. We studied leaching of P from 10-cmhigh lysimeters filled with intact grassland soil or with acid-washed sand. A manure patch was created on two grassland and two sandfilled lysimeters, and an additional

  6. Preparation of Mucoadhesive Patches for Buccal Administration of ...

    African Journals Online (AJOL)

    Purpose: To develop mucoadhesive patches for buccal administration of metoprolol succinate and to evaluate their in vitro and in vivo bioadhesion. Methods: The mucoadhesive buccal patches were prepared by solvent casting technique using two different mucoadhesive polymers. The formulations were tested for in vitro ...

  7. Cell-Detection Technique for Automated Patch Clamping

    Science.gov (United States)

    McDowell, Mark; Gray, Elizabeth

    2008-01-01

    A unique and customizable machinevision and image-data-processing technique has been developed for use in automated identification of cells that are optimal for patch clamping. [Patch clamping (in which patch electrodes are pressed against cell membranes) is an electrophysiological technique widely applied for the study of ion channels, and of membrane proteins that regulate the flow of ions across the membranes. Patch clamping is used in many biological research fields such as neurobiology, pharmacology, and molecular biology.] While there exist several hardware techniques for automated patch clamping of cells, very few of those techniques incorporate machine vision for locating cells that are ideal subjects for patch clamping. In contrast, the present technique is embodied in a machine-vision algorithm that, in practical application, enables the user to identify good and bad cells for patch clamping in an image captured by a charge-coupled-device (CCD) camera attached to a microscope, within a processing time of one second. Hence, the present technique can save time, thereby increasing efficiency and reducing cost. The present technique involves the utilization of cell-feature metrics to accurately make decisions on the degree to which individual cells are "good" or "bad" candidates for patch clamping. These metrics include position coordinates (x,y) in the image plane, major-axis length, minor-axis length, area, elongation, roundness, smoothness, angle of orientation, and degree of inclusion in the field of view. The present technique does not require any special hardware beyond commercially available, off-the-shelf patch-clamping hardware: A standard patchclamping microscope system with an attached CCD camera, a personal computer with an imagedata- processing board, and some experience in utilizing imagedata- processing software are all that are needed. A cell image is first captured by the microscope CCD camera and image-data-processing board, then the image

  8. Physically Connected Stacked Patch Antenna Design with 100% Bandwidth

    KAUST Repository

    Klionovski, Kirill; Shamim, Atif

    2017-01-01

    Typically, stacked patch antennas are parasitically coupled and provide larger bandwidth than a single patch antenna. Here, we show a stacked patch antenna design where square patches with semi-circular cutouts are physically connected to each other. This arrangement provides 100% bandwidth from 23.9–72.2 GHz with consistent high gain (5 dBi or more) across the entire bandwidth. In another variation, a single patch loaded with a superstrate provides 83.5% bandwidth from 25.6–62.3 GHz. The mechanism of bandwidth enhancement is explained through electromagnetic simulations. Measured reflection coefficient, radiation patterns and gain results confirm the extremely wideband performance of the design.

  9. Recent and relict topography of Boo Bee patch reef, Belize

    Science.gov (United States)

    Halley, R.B.; Shinn, E.A.; Hudson, J.H.; Lidz, B.; Taylor, D.L.

    1977-01-01

    Five core borings were taken on and around Boo Bee Patch Reef to better understand the origin of such shelf lagoon reefs. The cores reveal 4 stages of development: (1) subaerial exposure of a Pleistocene "high" having about 8 meters of relief, possibly a Pleistocene patch reef; (2) deposition of peat and impermeable terrigenous clay 3 meters thick around the high; (3) initiation of carbonate sediment production by corals and algae on the remaining 5 meters of hard Pleistocene topography and carbonate mud on the surrounding terrigenous clay; and (4) accelerated organic accumulation on the patch reef. Estimates of patch reef sedimentation rates (1.6 m/1000 years) are 3 to 4 times greater than off-reef sedimentation rates (0.4-0.5 m/1000 years). During periods of Pleistocene sedimentation on the Belize shelf, lagoon patch reefs may have grown above one another, stacking up to form reef accumulation of considerable thickness.

  10. Physically Connected Stacked Patch Antenna Design with 100% Bandwidth

    KAUST Repository

    Klionovski, Kirill

    2017-11-01

    Typically, stacked patch antennas are parasitically coupled and provide larger bandwidth than a single patch antenna. Here, we show a stacked patch antenna design where square patches with semi-circular cutouts are physically connected to each other. This arrangement provides 100% bandwidth from 23.9–72.2 GHz with consistent high gain (5 dBi or more) across the entire bandwidth. In another variation, a single patch loaded with a superstrate provides 83.5% bandwidth from 25.6–62.3 GHz. The mechanism of bandwidth enhancement is explained through electromagnetic simulations. Measured reflection coefficient, radiation patterns and gain results confirm the extremely wideband performance of the design.

  11. Biological effects of brachytherapy using a 32P-patch on the skin of Sencar mice

    International Nuclear Information System (INIS)

    Salgueiro, M.J.; Collia, N.; Duran, H.; Palmieri, M.; Medina, V.; Ughetti, R.; Nicolini, J.; Zubillaga, M.

    2009-01-01

    In recent years, specially designed patches containing beta emitters have been developed for contact brachytherapy of skin lesions. The aim of the present work was to evaluate the biological effects of the 32 P-patch on the skin of Sencar mice as a result of a brachytherapy treatment. For this purpose, a 32 P-patch was prepared with Chromic 32 P-phosphate and silicone and the classical model of two-stage skin carcinogenesis was reproduced in Sencar mice. Animals were divided in six groups. Four groups received the contact brachytherapy treatments using a scheme of a single session of 40 and 60 Gy (SD40 and SD60) and a scheme of two sessions of 40 and 60 Gy each (FD40 and FD60). The other two groups were used as controls of the single (CSD) and the fractionated (CFD) treatments. Radiation doses were estimated with equations derived from the MIRD DOSE scheme, and biologically effective doses (BED) were calculated according to equations derived from the linear-quadratic model. The endpoint to evaluate the treatments effects was tumor size after a follow-up period of 44 days. Finally, animals were sacrificed in order to get samples of all tumors for histological analysis and PCNA staining. Erythema, dermatitis and skin ulceration developed in almost all treated animals, but they gradually healed with regeneration of tissue during the follow-up period. Radiation effects on the skin of SD40, SD60, FD40 and FD60 showed a significant reduction of the tumor size with regard to controls, independently of the scheme and the radiation dose considered. PCNA staining scores of control groups were higher than for treated groups, independently of the scheme and the radiation dose considered. This radioactive 32 P-silicone-patch which is easy to prepare and use in the treatment of skin diseases, seems promising as a radioactive device for clinical use.

  12. Prior knowledge about spatial pattern affects patch assessment rather than movement between patches in tactile-feeding Mallard

    NARCIS (Netherlands)

    Klaassen, R.H.G.; Nolet, B.A.; Van Leeuwen, C.H.A.

    2007-01-01

    1. Heterogeneity in food abundance allows a forager to concentrate foraging effort in patches that are rich in food. This might be problematic when food is cryptic, as the content of patches is unknown prior to foraging. In such case knowledge about the spatial pattern in the distribution of food

  13. Autologous patch graft in tube shunt surgery.

    Science.gov (United States)

    Aslanides, I M; Spaeth, G L; Schmidt, C M; Lanzl, I M; Gandham, S B

    1999-10-01

    To evaluate an alternate method of covering the subconjunctival portion of the tube in aqueous shunt surgery. Evidence of tube erosion, graft-related infection, graft melting, or other associated intraocular complications were evaluated. A retrospective study of 16 patients (17 eyes) who underwent tube shunt surgery at Wills Eye Hospital between July 1991 and October 1996 was conducted. An autologous either "free" or "rotating" scleral lamellar graft was created to cover the subconjunctival portion of the tube shunt. All patients were evaluated for at least 6 months, with a mean follow-up of 14.8 months (range 6-62 months). All eyes tolerated the autologous graft well, with no clinical evidence of tube erosion, or graft-related or intraocular complications. Autologous patch graft in tube shunt surgery appears--in selected cases--to be an effective, safe and inexpensive surgical alternative to allogenic graft materials. It also offers ease of availability, and eliminates the risk of transmitting infectious disease.

  14. Patch testing with constituents of Compositae mixes.

    Science.gov (United States)

    Paulsen, Evy; Andersen, Klaus E

    2012-05-01

    The development of mixes containing Compositae plant extracts has improved the diagnosis of Compositae contact allergy, but none of them has fulfilled the criteria for an ideal European plant mix. To evaluate which constituents of two commercial Compositae mixes were most useful as screening agents. These comprised 76 patients testing positive to Compositae mix 6% in petrolatum and 29 patients testing positive to Compositae mix 5% pet., all of whom were tested with constituents of the respective mixes. The majority of patients tested positive to parthenolide or parthenolide-containing extracts, followed by German chamomile, yarrow, and arnica. As German chamomile is a weak sensitizer, the results suggest cross-reactions or reactions to unknown allergens. No one was positive to Roman chamomile. Even though parthenolide seems to be a suitable supplement to the baseline series, the results emphasize that it is important to patch test with extracts of native or locally grown plants, not only because of the geographical variation, but also because of the potential unknown allergens contained in short ether preparations and the variability in the individual patient's exposure and cross-reaction patterns. © 2012 John Wiley & Sons A/S.

  15. Multiband Patch Antenna for Femtocell Application

    Directory of Open Access Journals (Sweden)

    M. R. Zaman

    2014-01-01

    Full Text Available A microstrip patch antenna for multiple LTE (long term evaluation frequency bands for femtocell application is proposed in this paper. Distributed antenna solution (DAS has been introduced in cellular network to achieve homogenous indoor coverage. Femtocell is the latest extension to these solutions. It is a smart solution to both coverage and capacity scales. Femtocell operation in LTE band is occupied by higher frequency bands. For multiband femtocell application, miniature antenna design is quite essential. The antenna proposed here is composed of basic monopole structure with two parasitic elements at both sides of the active element. A rectangular slot is introduced at the ground plane of the proposed antenna. The antenna is designed using ElnoS HK light CCL substrate material of relative permittivity of 9.4, dielectric loss-tangent of 0.003 and thickness of 3 mm. The S11 response of the antenna is shown to have a bandwidth of 1.01 GHz starting from 1.79 GHz to 2.8 GHz. The characteristics of the antenna are analysed using Ansoft HFSS software.

  16. Improvement in current density of nano- and micro-structured Si solar cells by cost-effective elastomeric stamp process

    Science.gov (United States)

    Jeon, Kiseok; Jee, Hongsub; Lim, Sangwoo; Park, Min Joon; Jeong, Chaehwan

    2018-03-01

    Effective incident light should be controlled for improving the current density of solar cells by employing nano- and micro-structures on silicon surface. The elastomeric stamp process, which is more cost effective and simpler than conventional photolithography, was proposed for the fabrication of nano- and micro-structures. Polydimethylsiloxane (PDMS) was poured on a mother pattern with a diameter of 6 μm and a spacing of 2 μm; then, curing was performed to create a PDMS mold. The regular micropattern was stamped on a low-viscosity resin-coated silicon surface, followed by the simple reactive ion etching process. Nano-structures were formed using the Ag-based electroless etching process. As etching time was increased to 6 min, reflectance decreased to 4.53% and current density improved from 22.35 to 34.72 mA/cm2.

  17. Sub-Patch Roughness in Earthquake Rupture Investigations

    KAUST Repository

    Zielke, Olaf

    2016-02-13

    Fault geometric complexities exhibit fractal characteristics over a wide range of spatial scales (<µm to >km) and strongly affect the rupture process at corresponding scales. Numerical rupture simulations provide a framework to quantitatively investigate the relationship between a fault\\'s roughness and its seismic characteristics. Fault discretization however introduces an artificial lower limit to roughness. Individual fault patches are planar and sub-patch roughness –roughness at spatial scales below fault-patch size– is not incorporated. Does negligence of sub-patch roughness measurably affect the outcome of earthquake rupture simulations? We approach this question with a numerical parameter space investigation and demonstrate that sub-patch roughness significantly modifies the slip-strain relationship –a fundamental aspect of dislocation theory. Faults with sub-patch roughness induce less strain than their planar-fault equivalents at distances beyond the length of a slipping fault. We further provide regression functions that characterize the stochastic effect sub-patch roughness.

  18. Patch dynamics and metapopulation theory: the case of successional species.

    Science.gov (United States)

    Amarasekare, P; Possingham, H

    2001-04-07

    We present a mathematical framework that combines extinction-colonization dynamics with the dynamics of patch succession. We draw an analogy between the epidemiological categorization of individuals (infected, susceptible, latent and resistant) and the patch structure of a spatially heterogeneous landscape (occupied-suitable, empty-suitable, occupied-unsuitable and empty-unsuitable). This approach allows one to consider life-history attributes that influence persistence in patchy environments (e.g., longevity, colonization ability) in concert with extrinsic processes (e.g., disturbances, succession) that lead to spatial heterogeneity in patch suitability. It also allows the incorporation of seed banks and other dormant life forms, thus broadening patch occupancy dynamics to include sink habitats. We use the model to investigate how equilibrium patch occupancy is influenced by four critical parameters: colonization rate, extinction rate, disturbance frequency and the rate of habitat succession. This analysis leads to general predictions about how the temporal scaling of patch succession and extinction-colonization dynamics influences long-term persistence. We apply the model to herbaceous, early-successional species that inhabit open patches created by periodic disturbances. We predict the minimum disturbance frequency required for viable management of such species in the Florida scrub ecosystem. Copyright 2001 Academic Press.

  19. Nickel patch test reactivity and the menstrual cycle

    DEFF Research Database (Denmark)

    Rohold, A E; Halkier-Sørensen, L; Thestrup-Pedersen, K

    1994-01-01

    Premenstrual exacerbation of allergic contact dermatitis and varying allergic patch test responses have been reported at different points of the period. Using a dilution series of nickel sulphate, we studied the variation in patch test reactivity in nickel allergic women in relation to the menstr......Premenstrual exacerbation of allergic contact dermatitis and varying allergic patch test responses have been reported at different points of the period. Using a dilution series of nickel sulphate, we studied the variation in patch test reactivity in nickel allergic women in relation...... were tested first on day 7-10 and the other half first on day 20-24. There was no difference in the degree of patch test reactivity, when the results from day 7-10 and day 20-24 were compared (p > 0.4). However, when we compared the patch test results from the first and second test procedure, we found...... of positive patch tests led to an increased skin reactivity towards the same allergen, when the patients were retested weeks later....

  20. Radiation resistance of elastomeric O-rings in mixed neutron and gamma fields: Testing methodology and experimental results

    Science.gov (United States)

    Zenoni, A.; Bignotti, F.; Donzella, A.; Donzella, G.; Ferrari, M.; Pandini, S.; Andrighetto, A.; Ballan, M.; Corradetti, S.; Manzolaro, M.; Monetti, A.; Rossignoli, M.; Scarpa, D.; Alloni, D.; Prata, M.; Salvini, A.; Zelaschi, F.

    2017-11-01

    Materials and components employed in the presence of intense neutron and gamma fields are expected to absorb high dose levels that may induce deep modifications of their physical and mechanical properties, possibly causing loss of their function. A protocol for irradiating elastomeric materials in reactor mixed neutron and gamma fields and for testing the evolution of their main mechanical and physical properties with absorbed dose has been developed. Four elastomeric compounds used for vacuum O-rings, one fluoroelastomer polymer (FPM) based and three ethylene propylene diene monomer rubber (EPDM) based, presently available on the market have been selected for the test. One EPDM is rated as radiation resistant in gamma fields, while the other elastomers are general purpose products. Particular care has been devoted to dosimetry calculations, since absorbed dose in neutron fields, unlike pure gamma fields, is strongly dependent on the material composition and, in particular, on the hydrogen content. The products have been tested up to about 2 MGy absorbed dose. The FPM based elastomer, in spite of its lower dose absorption in fast neutron fields, features the largest variations of properties, with a dramatic increase in stiffness and brittleness. Out of the three EPDM based compounds, one shows large and rapid changes in the main mechanical properties, whereas the other two feature more stable behaviors. The performance of the EPDM rated as radiation resistant in pure gamma fields does not appear significantly better than that of the standard product. The predictive capability of the accelerated irradiation tests performed as well as the applicable concepts of threshold of radiation damage is discussed in view of the use of the examined products in the selective production of exotic species facility, now under construction at the Legnaro National Laboratories of the Italian Istituto Nazionale di Fisica Nucleare. It results that a careful account of dose rate effects

  1. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

    Science.gov (United States)

    Leite, Vanessa Vieira; Lopes, Murilo Baena; Gonini Júnior, Alcides; Almeida, Marcio Rodrigues de; Moura, Sandra Kiss; Almeida, Renato Rodrigues de

    2014-01-01

    To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a 0.10-in ligating wire was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied.

  2. Investigation of the homogeneity of methacrylate allergens in commercially available patch test preparations

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2013-01-01

    The homogeneity of methacrylates in commercial patch test preparations has not yet been investigated. Inhomogeneous patch test preparations may give rise to false-negative or false-positive patch test results in patients suspected of having methacrylate allergy.......The homogeneity of methacrylates in commercial patch test preparations has not yet been investigated. Inhomogeneous patch test preparations may give rise to false-negative or false-positive patch test results in patients suspected of having methacrylate allergy....

  3. Patch testing in non-immediate cutaneous adverse drug reactions: value of extemporaneous patch tests.

    Science.gov (United States)

    Assier, Haudrey; Valeyrie-Allanore, Laurence; Gener, Gwendeline; Verlinde Carvalh, Muriel; Chosidow, Olivier; Wolkenstein, Pierre

    2017-11-01

    Patch testing following a standardized protocol is reliable for identifying the culprit drug in cutaneous adverse drug reactions (CADRs). However, these patch tests (PTs) require pharmaceutical material and staff, which are not always easily available. To evaluate an extemporaneous PT method in CADRs. We retrospectively analysed data for all patients referred to our department between March 2009 and June 2013 for patch testing after a non-immediate CADR. The patients who supplied their own suspected drugs were tested both with extemporaneous PTs and with conventional PTs. Extemporaneous PTs involved a nurse crushing and diluting the drug in pet. in a ratio of approximately one-third to two-thirds. Standardized PTs were performed according to guidelines, with commercial drugs diluted to 30% or with active ingredients diluted to 10%. We analysed the data for the two PT methods in terms of the number of positive test reactions, drugs tested, and type of CADR for patients in whom the two PT methods were used. In total, 75 of 156 patients underwent the two PT procedures, including 91 double tests. Overall, 21 tests gave positive reactions with the two methods, and 69 other tests gave negative results with the two methods. Our series yielded results similar to those of published series concerning the types of CADR and the drugs responsible. Our results suggest that, for CADRs, if a patient supplies a suspected drug but if the pharmaceutical material and staff are not available for conventional PTs, extemporaneous PTs performed by the nurse with the commercial drug used by the patient can be useful and reliable. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Experimental patch testing with chromium-coated materials

    DEFF Research Database (Denmark)

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten Stendahl

    2017-01-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10...... chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive...

  5. Fever following an Epidural Blood Patch in a Child

    Directory of Open Access Journals (Sweden)

    Agnes I. Hunyady

    2012-01-01

    Full Text Available There is increasing evidence that children suffer from the consequences of spontaneous or iatrogenic intracranial hypotension. Pediatric epidural blood patch is gaining popularity because of its ability to alter cerebrospinal fluid dynamics and to alleviate headaches attributed to low cerebrospinal fluid pressure. There is, however, still not enough data to document the safety profile of an epidural blood patch. Here we describe a case of a fever in a child temporally related to the administration of an epidural blood patch. This case depicts the dilemmas in making the diagnosis and instituting treatment for complications of this procedure in the pediatric population.

  6. Statistical study of auroral fragmentation into patches

    Science.gov (United States)

    Hashimoto, Ayumi; Shiokawa, Kazuo; Otsuka, Yuichi; Oyama, Shin-ichiro; Nozawa, Satonori; Hori, Tomoaki; Lester, Mark; Johnsen, Magnar Gullikstad

    2015-08-01

    The study of auroral dynamics is important when considering disturbances of the magnetosphere. Shiokawa et al. (2010, 2014) reported observations of finger-like auroral structures that cause auroral fragmentation. Those structures are probably produced by macroscopic instabilities in the magnetosphere, mainly of the Rayleigh-Taylor type. However, the statistical characteristics of these structures have not yet been investigated. Here based on observations by an all-sky imager at Tromsø (magnetic latitude = 67.1°N), Norway, over three winter seasons, we statistically analyzed the occurrence conditions of 14 large-scale finger-like structures that developed from large-scale auroral regions including arcs and 6 small-scale finger-like structures that developed in auroral patches. The large-scale structures were seen from midnight to dawn local time and usually appeared at the beginning of the substorm recovery phase, near the low-latitude boundary of the auroral region. The small-scale structures were primarily seen at dawn and mainly occurred in the late recovery phase of substorms. The sizes of these large- and small-scale structures mapped in the magnetospheric equatorial plane are usually larger than the gyroradius of 10 keV protons, indicating that the finger-like structures could be caused by magnetohydrodynamic instabilities. However, the scale of small structures is only twice the gyroradius of 10 keV protons, suggesting that finite Larmor radius effects may contribute to the formation of small-scale structures. The eastward propagation velocities of the structures are -40 to +200 m/s and are comparable with those of plasma drift velocities measured by the colocating Super Dual Auroral Radar Network radar.

  7. Patching It Up, Pulling It Forward

    Directory of Open Access Journals (Sweden)

    Marlon E. Pierce

    2015-11-01

    Full Text Available An important reason for making any software open source is to encourage code and other community contributions, resulting in more diverse developer communities coalescing around valuable software efforts. We believe the full picture of open developer communities is underappreciated by scientific and cyberinfrastructure open source software efforts. Free and open source licensing is popular in scientific and cyberinfrastructure software, and Web-based tools for source code management (such as GitHub and Bitbucket are in common use, but community building efforts and associated governance models that foster these communities need improvement. We propose here a simple mechanism to address this problem: developers should be given incentives to submit patches and to make other measurable contributions to code bases that they use but are not otherwise connected to, and projects should be given incentives to accept these outside contributions. As an example implementation, we outline a contest system with small monetary rewards for individuals and recognition for both individuals and projects. The goal is to change the mindset of scientific and cyberinfrastructure developers, converting them from passive downstream users to active contributors. We hypothesize that this easily measurable concrete action will contribute to the sustainability of many projects and also create a more flexible scientific workforce. Building this effort on currently available, federally funded software will establish a foundation of public data that can be used to verify our hypothesis. More broadly, the effort will demonstrate the benefits for scientific and cyberinfrastructure projects that adopt workable governance models that are already well established in the broader open source software ecosystem.

  8. Erythema-index of clinical patch test reactions

    DEFF Research Database (Denmark)

    Jemec, G B; Johansen, J D

    1995-01-01

    that the method could be used for the grading of eczematous reactions in a clinical setting as well. OBJECTIVE: To assess the usefulness of the erythema index for the quantification of eczematous reactions using the Derma-Spectrometer (Cortex technology, Hadsund, Denmark) in a clinical setting. METHOD......: The erythema index of 56 patch test reactions ranging from +? to +++, was compared to regional controls and negative patch tests (189). The effects of intrumental application pressure was studied in 5 volunteers. Statistical analysis was carried out using Mann-Whitney and Jonckheere-Terpstra tests. RESULTS......: The erythema-index was significantly higher in all degrees of patch test reactions than in uninvolved regional skin or negative patch tests. It also showed a significant positive trend for higher values in +, ++ and +++ reactions (P

  9. Excitation of waves in elastic waveguides by piezoelectric patch actuators

    CSIR Research Space (South Africa)

    Loveday, PW

    2006-01-01

    Full Text Available for waveguides excited by piezoelectric patch actuators. The waveguide is modelled using specially developed waveguide finite elements. These elements are formulated using a complex exponential to describe the wave propagation along the structure and finite...

  10. Smooth surfaces from bilinear patches: Discrete affine minimal surfaces

    KAUST Repository

    Kä ferbö ck, Florian; Pottmann, Helmut

    2013-01-01

    Motivated by applications in freeform architecture, we study surfaces which are composed of smoothly joined bilinear patches. These surfaces turn out to be discrete versions of negatively curved affine minimal surfaces and share many properties

  11. Smart Patches for Monitoring Fatigue Crack Growth in Aircraft Structures

    National Research Council Canada - National Science Library

    Ihn, Jeong-Beom

    2001-01-01

    A built-in cost-effective diagnostic system for monitoring crack growth in aircraft structures was developed, particularly for riveted fuselage joints and cracked aircraft parts with composite bonded patches...

  12. Disorganized Cortical Patches Suggest Prenatal Origin of Autism

    Science.gov (United States)

    ... 2014 Disorganized cortical patches suggest prenatal origin of autism NIH-funded study shows disrupted cell layering process ... study suggests that brain irregularities in children with autism can be traced back to prenatal development. “While ...

  13. Okeanos Explorer (EX1601): Transit and Mission Patch Test

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Normal underway operations and mapping patch testing. Bathymetric mapping of either the Murray or Molokai Fracture Zones during the transit to Hawaii is planned, as...

  14. Preparation of Mucoadhesive Patches for Buccal Administration of ...

    African Journals Online (AJOL)

    Erah

    Methods: The mucoadhesive buccal patches were prepared by solvent casting technique ... buccal absorption, in vitro drug release studies, moisture absorption as well as for in vitro and in vivo ... recovery time after exposure to stress and.

  15. Histological distinction between early allergic and irritant patch test reactions

    DEFF Research Database (Denmark)

    Vestergaard, L; Clemmensen, Ole; Sørensen, Flemming Brandt

    1999-01-01

    Comparative light microscopic studies have revealed subtle differences between allergic and irritant reactions in the skin. In the search for specific differences, we focussed on the early inflammatory response. This pilot study was conducted to test the hypothesis that follicular spongiosis can...... differentiate between early allergic and irritant patch test reactions. 8 patients with known contact allergy to either colophony or quarternium-15 participated in the study. In each patient, allergic and irritant patch tests reactions were elicited, and 4-mm punch biopsies were taken after 6 8 h from...... clinically equipotent reactions. Paired sets of slides were assessed blindly by 2 pathologists. 1 patient showing a pityrosporum folliculitis was excluded from the study. All biopsies from allergic patch tests were characterized by follicular spongiosis, while biopsies from irritant patch tests showed...

  16. Investigation of a nanostrip patch antenna in optical frequencies

    Science.gov (United States)

    Kashyap, Nitesh; Wani, Zamir Ahmad; Jain, Rishi; Khusboo; Dinesh Kumar, V.

    2014-08-01

    This is the first report and investigation of a patch antenna in optical frequency range. Variety of plasmonic nanoantenna reported so far is good at enhancing the local field intensity of light by orders of magnitude. However, their far-field radiation efficiency is very poor. The proposed patch antenna emits a directional beam with high efficacy in addition to enhancing the intensity of near field. The nano-patch antenna (NPA) consists of a square patch of gold film of dimension 480 nm2, placed on a substrate of dielectric constant \\varepsilon_{{r}} = 3.9 and thickness 150 nm with a ground plane of gold film of dimension 1,080 nm2. The NPA resonates at 210 THz and has gain nearly 2 dB and radiation efficiency 45.18 %. The NPA might be useful in variety of applications such as optical communication, nano-photonics, biosensing, and spectroscopy.

  17. Wireless OAM transmission system based on elliptical microstrip patch antenna.

    Science.gov (United States)

    Chen, Jia Jia; Lu, Qian Nan; Dong, Fei Fei; Yang, Jing Jing; Huang, Ming

    2016-05-30

    The multiplexing transmission has always been a focus of attention for communication technology. In this paper, the radiation characteristics of circular microstrip patch antenna was firstly analyzed based on cavity model theory, and then spiral beams carrying orbital angular momentum (OAM) were generated, using elliptical microstrip patch antenna, with a single feed probe instead of a standard circular patch with two feedpoints. Moreover, by combining the proposed elliptic microstrip patch antenna with Universal Software Radio Peripheral (USRP), a wireless OAM transmission system was established and the real-time transmission of text, image and video in a real channel environment was realized. Since the wireless OAM transmission has the advantage of good safety and high spectrum utilization efficiency, this work has theoretical significance and potential application.

  18. Isoplanatic patch of the human eye for arbitrary wavelengths

    Science.gov (United States)

    Han, Guoqing; Cao, Zhaoliang; Mu, Quanquan; Wang, Yukun; Li, Dayu; Wang, Shaoxin; Xu, Zihao; Wu, Daosheng; Hu, Lifa; Xuan, Li

    2018-03-01

    The isoplanatic patch of the human eye is a key parameter for the adaptive optics system (AOS) designed for retinal imaging. The field of view (FOV) usually sets to the same size as the isoplanatic patch to obtain high resolution images. However, it has only been measured at a specific wavelength. Here we investigate the wavelength dependence of this important parameter. An optical setup is initially designed and established in a laboratory to measure the isoplanatic patch at various wavelengths (655 nm, 730 nm and 808 nm). We established the Navarro wide-angle eye model in Zemax software to further validate our results, which suggested high consistency between the two. The isoplanatic patch as a function of wavelength was obtained within the range of visible to near-infrared, which can be expressed as: θ=0.0028 λ - 0 . 74. This work is beneficial for the AOS design for retinal imaging.

  19. Development of a thermostable microneedle patch for influenza vaccination

    Science.gov (United States)

    Mistilis, Matthew; Bommarius, Andreas S; Prausnitz, Mark R.

    2017-01-01

    The goal of this study is to develop thermostable microneedle patch formulations for influenza vaccine that can be partially or completely removed from the cold chain. During vaccine drying associated with microneedle patch manufacturing, ammonium acetate and HEPES buffer salts stabilized influenza vaccine, surfactants had little effect during drying, drying temperature had weak effects on vaccine stability, and drying on polydimethylsiloxane led to increased stability compared to drying on stainless steel. A number of excipients, mostly polysaccharides and some amino acids, further stabilized the influenza vaccine during drying. Over longer time scales of storage, combinations of stabilizers preserved the most vaccine activity. Finally, dissolving microneedle patches formulated with arginine and calcium heptagluconate had no significant activity loss for all three strains of seasonal influenza vaccine during storage at room temperature for six months. We conclude that appropriately formulated microneedle patches can exhibit remarkable thermostability that could enable storage and distribution of influenza vaccine outside the cold chain. PMID:25448542

  20. Spotlight on Psoriasis: Preventing Patches of Itchy, Sore Skin

    Science.gov (United States)

    ... Subscribe August 2016 Print this issue Spotlight on Psoriasis Preventing Patches of Itchy, Sore Skin En español ... Sun Damage Sun and Skin Wise Choices Avoid Psoriasis Triggers Factors that may trigger psoriasis or make ...

  1. Microneedle Patches as Drug and Vaccine Delivery Platform.

    Science.gov (United States)

    Li, Junwei; Zeng, Mingtao; Shan, Hu; Tong, Chunyi

    2017-01-01

    Transcutaneous delivery is the ideal method for delivering therapeutic reagents or vaccines into skin. With their promise of self-administration, cost-effective and high efficiency, microneedle patches have been studied intensively as therapeutic and vaccination delivery platform that replaces injection by syringe. This review aims to summarize the recent advancements of microneedle patches in application for drugs and vaccine delivery. We reviewed the most of recently published papers on microneedle patches, summarized their evolution, classification, state-of the-art capabilities and discussed promising application in drugs and vaccine delivery. With the rapid development of nanotechnology, microneedle patches have been improved by switching from undissolving to dissolving microneedles, and their safety has also improved dramatically. As a drug delivery tool, microneedle patches can deliver bioactive molecular of different physical size. Additionally, microneedle patches can be coated or encapsulate with DNA vaccine, subunit antigen, inactivated or live virus vaccine. Combining clinical results with the results of patient interview, microneedle patches are found to be feasible and are predicated to soon be acceptable for the medical service. In this review, we summarized the evolution, current and future application of microneedle patches as delivery vehicle for drugs and vaccines. Compared with traditional delivery tools, microneedle patches have many advantages, such as providing pain-free, non-invasive, convenient route for reagent administration and delivery, with no cold chain required for storage and transportation as well as decreasing sharp medical waste, needle-caused injury and transmission of blood-borne infectious disease in rural area. However, even though there are dramatic progress in preclinical investigation of microneedle patches, further testing will be required for clinical application. Further research should be implemented in multiple fields

  2. Dynamics of Hierarchical Urban Green Space Patches and Implications for Management Policy.

    Science.gov (United States)

    Yu, Zhoulu; Wang, Yaohui; Deng, Jinsong; Shen, Zhangquan; Wang, Ke; Zhu, Jinxia; Gan, Muye

    2017-06-06

    Accurately quantifying the variation of urban green space is the prerequisite for fully understanding its ecosystem services. However, knowledge about the spatiotemporal dynamics of urban green space is still insufficient due to multiple challenges that remain in mapping green spaces within heterogeneous urban environments. This paper uses the city of Hangzhou to demonstrate an analysis methodology that integrates sub-pixel mapping technology and landscape analysis to fully investigate the spatiotemporal pattern and variation of hierarchical urban green space patches. Firstly, multiple endmember spectral mixture analysis was applied to time series Landsat data to derive green space coverage at the sub-pixel level. Landscape metric analysis was then employed to characterize the variation pattern of urban green space patches. Results indicate that Hangzhou has experienced a significant loss of urban greenness, producing a more fragmented and isolated vegetation landscape. Additionally, a remarkable amelioration of urban greenness occurred in the city core from 2002 to 2013, characterized by the significant increase of small-sized green space patches. The green space network has been formed as a consequence of new urban greening strategies in Hangzhou. These strategies have greatly fragmented the built-up areas and enriched the diversity of the urban landscape. Gradient analysis further revealed a distinct pattern of urban green space landscape variation in the process of urbanization. By integrating both sub-pixel mapping technology and landscape analysis, our approach revealed the subtle variation of urban green space patches which are otherwise easy to overlook. Findings from this study will help us to refine our understanding of the evolution of heterogeneous urban environments.

  3. Black-hole excision with multiple grid patches

    International Nuclear Information System (INIS)

    Thornburg, Jonathan

    2004-01-01

    When using black-hole excision to numerically evolve a black-hole spacetime with no continuous symmetries, most 3 + 1 finite differencing codes use a Cartesian grid. It is difficult to do excision on such a grid because the natural r = constant excision surface must be approximated either by a very different shape such as a contained cube, or by an irregular and non-smooth 'LEGO 1 sphere' which may introduce numerical instabilities into the evolution. In this paper I describe an alternate scheme which uses multiple {r x (angular coordinates)} grid patches, each patch using a different (nonsingular) choice of angular coordinates. This allows excision on a smooth r = constant 2-sphere. I discuss the key design choices in such a multiple-patch scheme, including the choice of ghost-zone versus internal-boundary treatment of the interpatch boundaries (I use a ghost-zone scheme), the number and shape of the patches (I use a 6-patch 'inflated-cube' scheme), the details of how the ghost zones are 'synchronized' by interpolation from neighbouring patches, the tensor basis for the Einstein equations in each patch, and the handling of non-tensor field variables such as the BSSN Γ-tilde i (I use a scheme which requires ghost zones which are twice as wide for the BSSN conformal factor φ as for Γ-tilde i and the other BSSN field variables). I present sample numerical results from a prototype implementation of this scheme. This code simulates the time evolution of the (asymptotically flat) spacetime around a single (excised) black hole, using fourth-order finite differencing in space and time. Using Kerr initial data with J/m 2 = 0.6, I present evolutions to t ∼> 1500m. The lifetime of these evolutions appears to be limited only by outer boundary instabilities, not by any excision instabilities or by any problems inherent to the multiple-patch scheme

  4. Force-controlled patch clamp of beating cardiac cells.

    Science.gov (United States)

    Ossola, Dario; Amarouch, Mohamed-Yassine; Behr, Pascal; Vörös, János; Abriel, Hugues; Zambelli, Tomaso

    2015-03-11

    From its invention in the 1970s, the patch clamp technique is the gold standard in electrophysiology research and drug screening because it is the only tool enabling accurate investigation of voltage-gated ion channels, which are responsible for action potentials. Because of its key role in drug screening, innovation efforts are being made to reduce its complexity toward more automated systems. While some of these new approaches are being adopted in pharmaceutical companies, conventional patch-clamp remains unmatched in fundamental research due to its versatility. Here, we merged the patch clamp and atomic force microscope (AFM) techniques, thus equipping the patch-clamp with the sensitive AFM force control. This was possible using the FluidFM, a force-controlled nanopipette based on microchanneled AFM cantilevers. First, the compatibility of the system with patch-clamp electronics and its ability to record the activity of voltage-gated ion channels in whole-cell configuration was demonstrated with sodium (NaV1.5) channels. Second, we showed the feasibility of simultaneous recording of membrane current and force development during contraction of isolated cardiomyocytes. Force feedback allowed for a gentle and stable contact between AFM tip and cell membrane enabling serial patch clamping and injection without apparent cell damage.

  5. Scale-adaptive Local Patches for Robust Visual Object Tracking

    Directory of Open Access Journals (Sweden)

    Kang Sun

    2014-04-01

    Full Text Available This paper discusses the problem of robustly tracking objects which undergo rapid and dramatic scale changes. To remove the weakness of global appearance models, we present a novel scheme that combines object’s global and local appearance features. The local feature is a set of local patches that geometrically constrain the changes in the target’s appearance. In order to adapt to the object’s geometric deformation, the local patches could be removed and added online. The addition of these patches is constrained by the global features such as color, texture and motion. The global visual features are updated via the stable local patches during tracking. To deal with scale changes, we adapt the scale of patches in addition to adapting the object bound box. We evaluate our method by comparing it to several state-of-the-art trackers on publicly available datasets. The experimental results on challenging sequences confirm that, by using this scale-adaptive local patches and global properties, our tracker outperforms the related trackers in many cases by having smaller failure rate as well as better accuracy.

  6. Relevance of positive patch-test reactions to fragrance mix.

    Science.gov (United States)

    Devos, Steven A; Constandt, Lieve; Tupker, Ron A; Noz, Kathy C; Lucker, Georges P H; Bruynzeel, Derk P; Schuttelaar, Marie-Louise A; Kruyswijk, Mente R J; van Zuuren, Esther J; Vink, Jaqueline; Coenraads, Pieter-Jan; Kiemeney, Lambertus A L M; van der Valk, Pieter G M

    2008-01-01

    Fragrances are an important cause of allergic contact dermatitis. We presume that the traditional fragrance mix (FM) detects 70 to 80% of fragrance-allergic patients. FM has an irritant potential. Weak positive reactions may have a greater chance of being irrelevant than strong reactions. To improve the appraisal of FM patch-test reactions, we studied the relevance of reactions of different strength. We also studied the predictive value of the following on the relevance of the initial FM patch-test results: patch-test results of a repeated FM test; results of patch tests with balsam of Peru, colophony, and ingredients of the mix; and (history of) atopic dermatitis. One hundred thirty-eight patients who had doubtful positive (?+) or positive (+ to +++) reactions were included in the study. We determined relevance by history taking, location and course of the dermatitis, and additional patch testing. Patients were retested with FM and with each ingredient separately. The relevance of reactions to FM increases with the strength of the reactions. Predictors of relevance are the results of retesting with FM, the results of tests with the ingredients, and a history and/or present symptoms of atopic dermatitis. Retesting with FM and its ingredients may add to the benefit of patch testing.

  7. Living cardiac patch: the elixir for cardiac regeneration.

    Science.gov (United States)

    Lakshmanan, Rajesh; Krishnan, Uma Maheswari; Sethuraman, Swaminathan

    2012-12-01

    A thorough understanding of the cellular and muscle fiber orientation in left ventricular cardiac tissue is of paramount importance for the generation of artificial cardiac patches to treat the ischemic myocardium. The major challenge faced during cardiac patch engineering is to choose a perfect combination of three entities; cells, scaffolds and signaling molecules comprising the tissue engineering triad for repair and regeneration. This review provides an overview of various scaffold materials, their mechanical properties and fabrication methods utilized in cardiac patch engineering. Stem cell therapies in clinical trials and the commercially available cardiac patch materials were summarized in an attempt to provide a recent perspective in the treatment of heart failure. Various tissue engineering strategies employed thus far to construct viable thick cardiac patches is schematically illustrated. Though many strategies have been proposed for fabrication of various cardiac scaffold materials, the stage and severity of the disease condition demands the incorporation of additional cues in a suitable scaffold material. The scaffold may be nanofibrous patch, hydrogel or custom designed films. Integration of stem cells and biomolecular cues along with the scaffold may provide the right microenvironment for the repair of unhealthy left ventricular tissue as well as promote its regeneration.

  8. Successful application of large microneedle patches by human volunteers.

    Science.gov (United States)

    Ripolin, Anastasia; Quinn, James; Larrañeta, Eneko; Vicente-Perez, Eva Maria; Barry, Johanne; Donnelly, Ryan F

    2017-04-15

    We describe, for the first time, the design, production and evaluation of large microneedle patches. Such systems, based on 16 individual microneedle arrays (needle height 600μm), were prepared from aqueous blends of 15% w/w Gantrez ® S97 and 7.5% w/w poly(ethyleneglycol) 10,000Da. Ester-based crosslinking was confirmed by FTIR and mechanical strength was good. Insertion depths in a validated skin model were approximately 500μm. Ten human volunteers successfully self-inserted the microneedles of these larger patches in their skin, following appropriate instruction, as confirmed by transepidermal water loss measurements. The mean insertion depth ranged between 300 and 450μm over the area of the large patches. That this was not significantly different to a single unit MN patch self-applied by the same volunteers is encouraging. Microneedle patch sizes much larger than the 1-2cm 2 will be required if this technology is to be successfully translated to clinic for delivery of drug substances. The work described here suggests that use of such larger patches by patients can be successful, potentially opening up the possibility for a significant expansion of the size of the market for transdermal drug delivery. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  9. Stability of penicillin G sodium diluted with 0.9% sodium chloride injection or 5% dextrose injection and stored in polyvinyl chloride bag containers and elastomeric pump containers.

    Science.gov (United States)

    Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire

    2014-04-15

    The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.

  10. Improved image registration by sparse patch-based deformation estimation.

    Science.gov (United States)

    Kim, Minjeong; Wu, Guorong; Wang, Qian; Lee, Seong-Whan; Shen, Dinggang

    2015-01-15

    Despite intensive efforts for decades, deformable image registration is still a challenging problem due to the potential large anatomical differences across individual images, which limits the registration performance. Fortunately, this issue could be alleviated if a good initial deformation can be provided for the two images under registration, which are often termed as the moving subject and the fixed template, respectively. In this work, we present a novel patch-based initial deformation prediction framework for improving the performance of existing registration algorithms. Our main idea is to estimate the initial deformation between subject and template in a patch-wise fashion by using the sparse representation technique. We argue that two image patches should follow the same deformation toward the template image if their patch-wise appearance patterns are similar. To this end, our framework consists of two stages, i.e., the training stage and the application stage. In the training stage, we register all training images to the pre-selected template, such that the deformation of each training image with respect to the template is known. In the application stage, we apply the following four steps to efficiently calculate the initial deformation field for the new test subject: (1) We pick a small number of key points in the distinctive regions of the test subject; (2) for each key point, we extract a local patch and form a coupled appearance-deformation dictionary from training images where each dictionary atom consists of the image intensity patch as well as their respective local deformations; (3) a small set of training image patches in the coupled dictionary are selected to represent the image patch of each subject key point by sparse representation. Then, we can predict the initial deformation for each subject key point by propagating the pre-estimated deformations on the selected training patches with the same sparse representation coefficients; and (4) we

  11. Large-scale binding ligand prediction by improved patch-based method Patch-Surfer2.0.

    Science.gov (United States)

    Zhu, Xiaolei; Xiong, Yi; Kihara, Daisuke

    2015-03-01

    Ligand binding is a key aspect of the function of many proteins. Thus, binding ligand prediction provides important insight in understanding the biological function of proteins. Binding ligand prediction is also useful for drug design and examining potential drug side effects. We present a computational method named Patch-Surfer2.0, which predicts binding ligands for a protein pocket. By representing and comparing pockets at the level of small local surface patches that characterize physicochemical properties of the local regions, the method can identify binding pockets of the same ligand even if they do not share globally similar shapes. Properties of local patches are represented by an efficient mathematical representation, 3D Zernike Descriptor. Patch-Surfer2.0 has significant technical improvements over our previous prototype, which includes a new feature that captures approximate patch position with a geodesic distance histogram. Moreover, we constructed a large comprehensive database of ligand binding pockets that will be searched against by a query. The benchmark shows better performance of Patch-Surfer2.0 over existing methods. http://kiharalab.org/patchsurfer2.0/ CONTACT: dkihara@purdue.edu Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Patch Transporter: Incentivized, Decentralized Software Patch System for WSN and IoT Environments

    Science.gov (United States)

    Lee, JongHyup

    2018-01-01

    In the complicated settings of WSN (Wireless Sensor Networks) and IoT (Internet of Things) environments, keeping a number of heterogeneous devices updated is a challenging job, especially with respect to effectively discovering target devices and rapidly delivering the software updates. In this paper, we convert the traditional software update process to a distributed service. We set an incentive system for faithfully transporting the patches to the recipient devices. The incentive system motivates independent, self-interested transporters for helping the devices to be updated. To ensure the system correctly operates, we employ the blockchain system that enforces the commitment in a decentralized manner. We also present a detailed specification for the proposed protocol and validate it by model checking and simulations for correctness. PMID:29438337

  13. Patch Transporter: Incentivized, Decentralized Software Patch System for WSN and IoT Environments.

    Science.gov (United States)

    Lee, JongHyup

    2018-02-13

    [-12]In the complicated settings of WSN (Wireless Sensor Networks) and IoT (Internet of Things) environments, keeping a number of heterogeneous devices updated is a challenging job, especially with respect to effectively discovering target devices and rapidly delivering the software updates. In this paper, we convert the traditional software update process to a distributed service. We set an incentive system for faithfully transporting the patches to the recipient devices. The incentive system motivates independent, self-interested transporters for helping the devices to be updated. To ensure the system correctly operates, we employ the blockchain system that enforces the commitment in a decentralized manner. We also present a detailed specification for the proposed protocol and validate it by model checking and simulations for correctness.

  14. Patch Transporter: Incentivized, Decentralized Software Patch System for WSN and IoT Environments

    Directory of Open Access Journals (Sweden)

    JongHyup Lee

    2018-02-01

    Full Text Available In the complicated settings of WSN (Wireless Sensor Networks and IoT (Internet of Things environments, keeping a number of heterogeneous devices updated is a challenging job, especially with respect to effectively discovering target devices and rapidly delivering the software updates. In this paper, we convert the traditional software update process to a distributed service. We set an incentive system for faithfully transporting the patches to the recipient devices. The incentive system motivates independent, self-interested transporters for helping the devices to be updated. To ensure the system correctly operates, we employ the blockchain system that enforces the commitment in a decentralized manner. We also present a detailed specification for the proposed protocol and validate it by model checking and simulations for correctness.

  15. Patch dynamics of a foraging assemblage of bees.

    Science.gov (United States)

    Wright, David Hamilton

    1985-03-01

    The composition and dynamics of foraging assemblages of bees were examined from the standpoint of species-level arrival and departure processes in patches of flowers. Experiments with bees visiting 4 different species of flowers in subalpine meadows in Colorado gave the following results: 1) In enriched patches the rates of departure of bees were reduced, resulting in increases in both the number of bees per species and the average number of species present. 2) The reduction in bee departure rates from enriched patches was due to mechanical factors-increased flower handling time, and to behavioral factors-an increase in the number of flowers visited per inflorescence and in the number of inflorescences visited per patch. Bees foraging in enriched patches could collect nectar 30-45% faster than those foraging in control patches. 3) The quantitative changes in foraging assemblages due to enrichment, in terms of means and variances of species population sizes, fraction of time a species was present in a patch, and in mean and variance of the number of species present, were in reasonable agreement with predictions drawn from queuing theory and studies in island biogeography. 4) Experiments performed with 2 species of flowers with different corolla tube lengths demonstrated that manipulation of resources of differing availability had unequal effects on particular subsets of the larger foraging community. The arrival-departure process of bees on flowers and the immigration-extinction process of species on islands are contrasted, and the value of the stochastic, species-level approach to community composition is briefly discussed.

  16. Design and characterization of a 32P-patch for the treatment of skin diseases. Studies of its application as a betatherapeutic agent for modulated brachytherapy

    International Nuclear Information System (INIS)

    Salgueiro, M. J.

    2010-01-01

    The purpose of this work was to design and evaluate a 32 P-patch for contact brachytherapy of skin diseases. [ 32 P]-chromic phosphate in combination with silicone was employed to produce the designed 32 P patch. Radiopharmaceutical production was carried out in accordance with radiological safety issues. To verify the safety of the 32 P-patch, stability studies in vitro and in vivo were carried out to evaluate the leakage of radioactivity and autoradiographic studies were performed to evaluate the dose homogeneity and shielding. Therapeutic efficacy in animal models of skin cancer as well as in cats with squamous cell carcinoma was evaluated. These results showed that independently of the considered model, tumor growth was arrested and complete regressions were achieved in some other cases. Radiation doses were estimated with equations derived from the MIRD DOSE scheme and compared with Monte Carlo β doses. Some advantages of the designed 32 P-patch allow its use for conformal and modulated radiotherapy such as the possibility of modifying the activity concentration of the patch, the limited range of β- radiation, dose deep distribution and combination with bolus. This 32 P-patch which is easy to prepare and control may be used in the treatment of skin diseases alone or in combination with other treatment modalities. (author)

  17. Accuracy of a new ring-opening metathesis elastomeric dental impression material with spray and immersion disinfection.

    Science.gov (United States)

    Kronström, Mats H; Johnson, Glen H; Hompesch, Richard W

    2010-01-01

    A new elastomeric impression material has been formulated with a ring-opening metathesis chemistry. In addition to other properties of clinical significance, the impression accuracy must be confirmed. The purpose of this study was to compare the accuracy of the new elastomeric impression material with vinyl polysiloxane and polyether following both spray and immersion disinfection. Impressions of a modified dentoform with a stainless steel crown preparation in the lower right quadrant were made, and type IV gypsum working casts and dies were formed. Anteroposterior (AP), cross-arch (CA), buccolingual (BL), mesiodistal (MD), occlusogingivobuccal (OGB), and occlusogingivolingual (OGL) dimensions were measured using a microscope. Working cast and die dimensions were compared to those of the master model. The impression materials were a newly formulated, ring-opening metathesis-polymerization impression material (ROMP Cartridge Tray and ROMP Volume Wash), vinyl polysiloxane (VPS, Aquasil Ultra Monophase/LV), and a polyether (PE, Impregum Penta Soft/Permadyne Garant L). Fifteen impressions with each material were made, of which 5 were disinfected by spray for 10 minutes (CaviCide), 5 were disinfected by immersion for 90 minutes (ProCide D), and 5 were not disinfected. There were significant cross-product interactions with a 2-way ANOVA, so a 1-way ANOVA and Dunnett's T3 multiple comparison test were used to compare the dimensional changes of the 3 impression materials, by disinfection status and for each location (alpha=.05). For ROMP, there were no significant differences from the master, for any dimension, when comparing the control and 2 disinfectant conditions. No significant differences were detected among the 3 impression materials for CA, BL, and MD. The working die dimensions of OGB and OGL for VPS with immersion disinfection were significantly shorter than with PE and ROMP (P<.05). Overall, the AP dimension was more accurate than CA, and the BL of working dies

  18. Nonlinear analysis of r.c. framed buildings retrofitted with elastomeric and friction bearings under near-fault earthquakes

    Science.gov (United States)

    Mazza, Mirko

    2015-12-01

    Reinforced concrete (r.c.) framed buildings designed in compliance with inadequate seismic classifications and code provisions present in many cases a high vulnerability and need to be retrofitted. To this end, the insertion of a base isolation system allows a considerable reduction of the seismic loads transmitted to the superstructure. However, strong near-fault ground motions, which are characterised by long-duration horizontal pulses, may amplify the inelastic response of the superstructure and induce a failure of the isolation system. The above considerations point out the importance of checking the effectiveness of different isolation systems for retrofitting a r.c. framed structure. For this purpose, a numerical investigation is carried out with reference to a six-storey r.c. framed building, which, primarily designed (as to be a fixed-base one) in compliance with the previous Italian code (DM96) for a medium-risk seismic zone, has to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by the current Italian code (NTC08) in a high-risk seismic zone. Besides the (fixed-base) original structure, three cases of base isolation are studied: elastomeric bearings acting alone (e.g. HDLRBs); in-parallel combination of elastomeric and friction bearings (e.g. high-damping-laminated-rubber bearings, HDLRBs and steel-PTFE sliding bearings, SBs); friction bearings acting alone (e.g. friction pendulum bearings, FPBs). The nonlinear analysis of the fixed-base and base-isolated structures subjected to horizontal components of near-fault ground motions is performed for checking plastic conditions at the potential critical (end) sections of the girders and columns as well as critical conditions of the isolation systems. Unexpected high values of ductility demand are highlighted at the lower floors of all base-isolated structures, while re-centring problems of the base isolation systems under near-fault earthquakes are

  19. Is It Safe to Uplift This Patch? An Empirical Study on Mozilla Firefox

    OpenAIRE

    Castelluccio, Marco; An, Le; Khomh, Foutse

    2017-01-01

    In rapid release development processes, patches that fix critical issues, or implement high-value features are often promoted directly from the development channel to a stabilization channel, potentially skipping one or more stabilization channels. This practice is called patch uplift. Patch uplift is risky, because patches that are rushed through the stabilization phase can end up introducing regressions in the code. This paper examines patch uplift operations at Mozilla, with the aim to ide...

  20. Rotigotine transdermal patch for the treatment of Parkinson's Disease.

    Science.gov (United States)

    Perez-Lloret, Santiago; Rey, María Verónica; Ratti, Pietro Lucca; Rascol, Olivier

    2013-02-01

    Rotigotine, a non-ergot dopamine agonist, has been developed as a novel transdermal formulation. The rotigotine transdermal patch has received EMEA marketing authorization for the treatment of adult patients with early or advanced Parkinson's disease (PD) or with moderate to severe restless legs syndrome (RLS). FDA originally granted a marketing authorization for early PD, which was later suspended, and is now studying the authorization for RLS. The aim of this review is to review the pharmacokinetics, pharmacodynamics as well as the clinical efficacy and tolerability of the rotigotine transdermal patch in PD. Source material was identified using a PubMed search for the term 'rotigotine' and PD. Articles published up to January 2011 or abstract submitted to most relevant international neurology congresses were reviewed. The rotigotine transdermal patch is efficacious for the treatment of PD. Tolerability profile appears to be well within the range of that observed with other non-ergot dopamine agonists in PD. Application-site reactions were the most frequent adverse event, and they were considered mild to moderate in the majority of cases. The rotigotine transdermal patch offers a safe and efficacious alternative for the treatment of PD. Further studies should focus on the possibility that continuous dopamine stimulation by means of the transdermal patch has any influence on levodopa-related motor complications. © 2012 The Authors Fundamental and Clinical Pharmacology © 2012 Société Française de Pharmacologie et de Thérapeutique.

  1. Results of patch testing with lavender oil in Japan.

    Science.gov (United States)

    Sugiura, M; Hayakawa, R; Kato, Y; Sugiura, K; Hashimoto, R

    2000-09-01

    We report the annual results of patch testing with lavender oil for a 9-year period from 1990 to 1998 in Japan. Using Finn Chambers and Scanpor tape, we performed 2-day closed patch testing with lavender oil 20% pet. on the upper back of each patient suspected of having cosmetic contact dermatitis. We compared the frequency of positive patch tests to lavender oil each year with those to other fragrances. We diagnosed contact allergy when patch test reactions were + or Japan, there has been a trend for aromatherapy using lavender oil. With this trend, placing dried lavender flowers in pillows, drawers, cabinets, or rooms has become a new fashion. We asked patients who showed a positive reaction to lavender oil about their use of dried lavender flowers. We confirmed the use of dried lavender flowers in 5 cases out of 11 positive cases in 1997 and 8 out of 15 positive cases in 1998. We concluded that the increase in patch test positivity rates to lavender oil in 1997 and 1998 was due to the above fashion, rather than due to fragrances in cosmetic products.

  2. Bilateral patching in retinal detachment: fluid mechanics and retinal "settling".

    Science.gov (United States)

    Foster, William J

    2011-07-20

    When a patient suffers a retinal detachment and surgery is delayed, it is known clinically that bilaterally patching the patient may allow the retina to partially reattach or "settle." Although this procedure has been performed since the 1860s, there is still debate as to how such a maneuver facilitates the reattachment of the retina. Finite element calculations using commercially available analysis software are used to elucidate the influence of reduction in eye movement caused by bilateral patching on the flow of subretinal fluid in a physical model of retinal detachment. It was found that by coupling fluid mechanics with structural mechanics, a physically consistent explanation of increased retinal detachment with eye movements can be found in the case of traction on the retinal hole. Large eye movements increase vitreous traction and detachment forces on the edge of the retinal hole, creating a subretinal vacuum and facilitating increased subretinal fluid. Alternative models, in which intraocular fluid flow is redirected into the subretinal space, are not consistent with these simulations. The results of these simulations explain the physical principles behind bilateral patching and provide insight that can be used clinically. In particular, as is known clinically, bilateral patching may facilitate a decrease in the height of a retinal detachment. The results described here provide a description of a physical mechanism underlying this technique. The findings of this study may aid in deciding whether to bilaterally patch patients and in counseling patients on pre- and postoperative care.

  3. A DOUBLE E SHAPED MICROSTRIP PATCH ANTENNA FOR MULTIBAND APPLICATIONS

    Directory of Open Access Journals (Sweden)

    Pristin K Mathew

    2014-06-01

    Full Text Available This paper presents a dual band Compact double E shaped Microstrip Patch antenna with enhanced gain for Worldwide Interoperability for Microwave Access (WI-MAX, Universal Mobile Telecommunication Systems (UMTS and Satellite applications. The modified E shaped patch antenna is designed using CADFEKO and the results of return loss, Voltage Standing Wave Ratio (VSWR, gain of the proposed antenna are compared with a conventional E shaped patch antenna. The results show that the double E shaped wideband patch antenna has an impedance bandwidth of 10.7 % with a return loss of -13.6dB, -12.4 dB, -12.1dB and -14.2dB at resonant frequencies of 1.96 GHz, 3.62 GHz, 5.76 GHz and 6.82 GHz, whereas a conventional E shaped patch antenna operates at 2.5 GHz, 3.4 GHz and 5.5 GHz with a return loss of -16 dB each and impedance bandwidth of 10.6 %. Both the antennas uses Coaxial Probe feeding technique and Flame Retardant 4 (FR-4 as the substrate material with a thickness of 2.87 mm. A parametric study has been done so as to understand the effect of each parameter to obtain a better performance and optimised results.

  4. Experimental patch testing with chromium-coated materials.

    Science.gov (United States)

    Bregnbak, David; Thyssen, Jacob P; Jellesen, Morten S; Zachariae, Claus; Johansen, Jeanne D

    2017-06-01

    Chromium coatings on metal alloys can be decorative, and prevent corrosion and metal ion release. We recently showed that handling of a chromium-containing disc resulted in chromium deposition on the skin. To examine patch test reactivity to chromium-coated discs. We included 15 patients: 10 chromium-allergic patients, and 5 patients without chromium allergy. All were patch tested with potassium dichromate, cobalt chloride, nickel sulfate, and nine different metallic discs. The chromium-allergic patients were also patch tested with serial dilutions of potassium dichromate. Positive/weaker reactions were observed to disc B (1 of 10), disc C (1 of 10), and disc D, disc E, and disc I (4 of 10 each). As no controls reacted to any of the discs, the weak reactions indicate allergic reactions. Positive patch test reactions to 1770 ppm chromium(VI) in the serial dilutions of potassium dichromate were observed in 7 of 10 patients. When the case group was narrowed down to include only the patients with a current positive patch test reaction to potassium dichromate, elicitation of dermatitis by both chromium(III) and chromium(VI) discs was observed in 4 of 7 of patients. Many of the patients reacted to both chromium(III) and chromium(VI) surfaces. Our results indicate that both chromium(VI) and chromium(III) pose a risk to chromium-allergic patients. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Modeling of endovascular patch welding using the computer program LATIS

    International Nuclear Information System (INIS)

    Glinsky, M.E.; London, R.A.; Zimmerman, G.B.; Jacques, S.L.

    1995-01-01

    A new computer program, LATIS, being developed at Lawrence Livermore National Laboratory is used to study the effect of pulsed laser irradiation on endovascular patch welding. Various physical and biophysical effects are included in these simulations: laser light scattering and absorption, tissue heating and heat conduction, vascular cooling, and tissue thermal damage. The geometry of a patch being held against the inner vessel wall (500 μm inner diameter) by a balloon is considered. The system is exposed to light pulsed from an optical fiber inside the balloon. A minimum in the depth of damage into the vessel wall is found. The minimum damage zone is about the thickness of the patch material that is heated by the laser. The more ordered the tissue the thinner the minimum zone of damage. The pulse length which minimizes the zone of damage is found to be the time for energy to diffuse across the layer. The delay time between the pulses is determined by the time for the heated layer to cool down. An optimal pulse length exists which minimizes the total time needed to weld the patch to the wall while keeping the thickness of the damaged tissue to less than 100 μm. For the case that is considered, a patch dyed with light absorbing ICG on the side next to the vessel (thickness of the dyed layer is 60 μm), the best protocol is found to be 65-200 ms pulses applied over 2 min

  6. Foraging decisions, patch use, and seasonality in egrets (Aves: ciconiiformes)

    Science.gov (United States)

    Erwin, R.M.

    1985-01-01

    Feeding snowy (Egretta thula) and great (Casmerodius albus) egrets were observed during 2 breeding seasons in coastal New Jersey and 2 brief winter periods in northeast Florida (USA). A number of tests based on assumptions of foraging models, predictions from foraging theory, and earlier empirical tests concerning time allocation and movement in foraging patches was made. Few of the expectations based on foraging theory and/or assumptions were supported by the empirical evidence. Snowy egrets fed with greater intensity and efficiency during the breeding season (when young were being fed) than during winter. They also showed some tendency to leave patches when their capture rate declined, and they spent more time foraging in patches when other birds were present nearby. Great egrets showed few of these tendencies, although they did leave patches when their intercapture intervals increased. Satiation differences had some influence on feeding rates in snowy egrets, but only at the end of feeding bouts. Some individuals of both species revisited areas in patches that had recently been exploited, and success rates were usually higher after the 2nd visit. Apparently, for predators of active prey, short-term changes in resource availability ('resource depression') may be more important than resource depletion, a common assumption in most optimal foraging theory models.

  7. Robust Tracking with Discriminative Ranking Middle-Level Patches

    Directory of Open Access Journals (Sweden)

    Hong Liu

    2014-04-01

    Full Text Available The appearance model has been shown to be essential for robust visual tracking since it is the basic criterion to locating targets in video sequences. Though existing tracking-by-detection algorithms have shown to be greatly promising, they still suffer from the drift problem, which is caused by updating appearance models. In this paper, we propose a new appearance model composed of ranking middle-level patches to capture more object distinctiveness than traditional tracking-by-detection models. Targets and backgrounds are represented by both low-level bottom-up features and high-level top-down patches, which can compensate each other. Bottom-up features are defined at the pixel level, and each feature gets its discrimination score through selective feature attention mechanism. In top-down feature extraction, rectangular patches are ranked according to their bottom-up discrimination scores, by which all of them are clustered into irregular patches, named ranking middle-level patches. In addition, at the stage of classifier training, the online random forests algorithm is specially refined to reduce drifting problems. Experiments on challenging public datasets and our test videos demonstrate that our approach can effectively prevent the tracker drifting problem and obtain competitive performance in visual tracking.

  8. Dissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone

    Science.gov (United States)

    Lee, Jeong Woo; Choi, Seong-O; Felner, Eric I.

    2014-01-01

    Clinical impact of biotechnology has been constrained by the limitations of traditional hypodermic injection of biopharmaceuticals. Microneedle patches have been proposed as a minimally invasive alternative. In this study, we assess the translation of a dissolving microneedle patch designed for simple, painless self-administration of biopharmacetucials that generates no sharp biohazardous waste. To study pharmacokinetics and safety of this approach, human growth hormone (hGH) was encapsulated in 600 μm long dissolving microneedles composed of carboxymethylcellulose and trehalose using an aqueous, moderate-temperature process that maintained complete hGH activity after encapsulation and retained most activity after storage for up to 15 months at room temperature and humidity. After manual insertion into the skin of hairless rats, hGH pharmacokinetics were similar to conventional subcutaneous injection. After patch removal, the microneedles had almost completely dissolved, leaving behind only blunt stubs. The dissolving microneedle patch was well tolerated, causing only slight, transient erythema. This study suggests that a dissolving microneedle patch can deliver hGH and other biopharmaceuticals in a manner suitable for self-administration without sharp biohazardous waste. PMID:21360810

  9. The effect of transdermal nicotine patches on sleep and dreams.

    Science.gov (United States)

    Page, F; Coleman, G; Conduit, R

    2006-07-30

    This study was undertaken to determine the effect of 24-h transdermal nicotine patches on sleep and dream mentation in 15 smokers aged 20 to 33. Utilising a repeated measures design, it was found that more time awake and more ASDA micro-arousals occurred while wearing the nicotine patch compared to placebo. Also, the percentage of REM sleep decreased, but REM latency and the proportion of time spent in NREM sleep stages did not change significantly. Dream reports containing visual imagery, visual imagery ratings and the number of visualizable nouns were significantly greater from REM compared to Stage 2 awakenings, regardless of patch condition. However, a general interaction effect was observed. Stage 2 dream variables remained equivalent across nicotine and placebo conditions. Within REM sleep, more dream reports containing visual imagery occurred while wearing the nicotine patch, and these were rated as more vivid. The greater frequency of visual imagery reports and higher imagery ratings specifically from REM sleep suggests that previously reported dreaming side effects from 24-h nicotine patches may be specific to REM sleep. Combined with previous animal studies showing that transdermally delivered nicotine blocks PGO activity in REM sleep, the current results do no appear consistent with PGO-based hypotheses of dreaming, such as the Activation-Synthesis (AS) or Activation, Input and Modulation (AIM) models.

  10. Phase separation and mechanical properties of an elastomeric biomaterial from spider wrapping silk and elastin block copolymers.

    Science.gov (United States)

    Muiznieks, Lisa D; Keeley, Fred W

    2016-10-01

    Elastin and silk spidroins are fibrous, structural proteins with elastomeric properties of extension and recoil. While elastin is highly extensible and has excellent recovery of elastic energy, silks are particularly strong and tough. This study describes the biophysical characterization of recombinant polypeptides designed by combining spider wrapping silk and elastin-like sequences as a strategy to rationally increase the strength of elastin-based materials while maintaining extensibility. We demonstrate a thermo-responsive phase separation and spontaneous colloid-like droplet formation from silk-elastin block copolymers, and from a 34 residue disordered region of Argiope trifasciata wrapping silk alone, and measure a comprehensive suite of tensile mechanical properties from cross-linked materials. Silk-elastin materials exhibited significantly increased strength, toughness, and stiffness compared to an elastin-only material, while retaining high failure strains and low energy loss upon recoil. These data demonstrate the mechanical tunability of protein polymer biomaterials through modular, chimeric recombination, and provide structural insights into mechanical design. © 2016 Wiley Periodicals, Inc. Biopolymers 105: 693-703, 2016. © 2016 Wiley Periodicals, Inc.

  11. Evaluation of the performance of elastomeric pumps in practice: are we under-delivering on chemotherapy treatments?

    Science.gov (United States)

    Salman, Dahlia; Biliune, Jurga; Kayyali, Reem; Ashton, Jane; Brown, Peter; McCarthy, Tim; Vikman, Elin; Barton, Stephen; Swinden, Julian; Nabhani-Gebara, Shereen

    2017-12-01

    Elastomeric pumps are widely used to facilitate ambulatory chemotherapy, and studies have shown that they are safe and well received by patients. Despite these advantages, their end of infusion time can fluctuate significantly. The aim of this research was to observe the performance of these pumps in real practice and to evaluate patients' satisfaction. This was a two-phase study conducted at three cancer units over 6 months. Phase-1 was an observational study recording the status of pumps at the scheduled disconnection time and noting remaining volume of infusion. Phase-2 was a survey of patients and their perception/satisfaction. Ethical approval was granted. A total of 92 cases were observed covering 50 cases disconnected at hospital and 42 disconnected at home. The infusion in 40% of hospital disconnection cases was slow, with patients arriving at hospital with unfinished pumps; 58% of these had an estimated remaining volume which exceeded 10 mL with 35% exceeded 20 mL. In 73% of these cases, and regardless of the remaining volume, the patient was disconnected and the pump was discarded. The performance of pumps varied, which affected nurse workload and patients' waiting-times. A smart system is an option to monitor the performance of pumps and to predict their accuracy.

  12. Atomic force microscopy and nanoindentation investigation of polydimethylsiloxane elastomeric substrate compliancy for various sputtered thin film morphologies.

    Science.gov (United States)

    Maji, Debashis; Das, Soumen

    2018-03-01

    Crack free electrically continuous metal thin films over soft elastomeric substrates play an integral part in realization of modern day flexible bioelectronics and biosensors. Under nonoptimized deposition conditions, delamination, and/or cracking of the top film as well as the underlying soft substrate hinders optimal performance of these devices. Hence it is very important to understand and control not only the various deposition factors like power, time, or deposition pressure but also investigate the various interfacial physics playing a critical role in assuring thin film adhesion and substrate compliancy. In the present study, various nanomechanical information of the underlying substrate, namely, crack profile, average roughness, Young's modulus, and adhesion force were studied for uncracked and cracked polydimethylsiloxane (PDMS) surfaces along with pristine and conventional plasma treated PDMS samples as control. Quantification of the above parameters were done using three-dimensional surface profiler, scanning electron microscopy, nanoindentation, and atomic force microscopy techniques to elucidate the modulus range, average roughness, and adhesion force. Comparative analysis with control revealed remarkable similarity between increased modulus values, increased surface roughness, and reduced adhesion force accounting for reduced substrate compliancy and resulting in film cracking or buckling which are critical for development of various bioflexible devices. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 725-737, 2018. © 2017 Wiley Periodicals, Inc.

  13. Heat shrink ability of electron-beam-modified thermoplastic elastomeric films from blends of ethylene-vinylacetate copolymer and polyethylene

    International Nuclear Information System (INIS)

    Chattopadhyay, S.; Chaki, T.K.; Bhowmick, Anil K.

    2000-01-01

    The heat shrink ability of electron-beam-irradiated thermoplastic elastomeric films from blends of ethylene-vinylacetate copolymer (EVA) and low-density polyethylene (LDPE) has been investigated in this paper. The effects of temperature, time and extent of stretching and shrinkage temperature and time have been reported. Based on the above data, the optimized conditions in terms of high heat shrinkage and low amnesia rating have been evaluated. Influence of radiation doses (0-500 kGy), multifunctional sensitizer levels (ditri methylol propane tetraacrylate, DTMPTA), and blend proportions on heat shrink ability has been explained with the help of gel fraction and X-ray data. With the increase in radiation dose, gel fraction increases, which in turn gives rise to low values of heat shrinkage and amnesia rating. At a constant radiation dose and blend ratio, percent heat shrinkage is found to decrease with increase in DTMPTA level. Gel content increases with the increase in EVA content of the blend at a constant radiation dose and monomer level, giving rise to decrease in heat shrink ability. Heat shrinkage increases with the increase in percent crystallinity, although the amnesia rating follows the reverse trend.

  14. Heat shrink ability of electron-beam-modified thermoplastic elastomeric films from blends of ethylene-vinylacetate copolymer and polyethylene

    Energy Technology Data Exchange (ETDEWEB)

    Chattopadhyay, S.; Chaki, T.K.; Bhowmick, Anil K. E-mail: anilkb@rtc.iitkgp.ernet.in

    2000-11-01

    The heat shrink ability of electron-beam-irradiated thermoplastic elastomeric films from blends of ethylene-vinylacetate copolymer (EVA) and low-density polyethylene (LDPE) has been investigated in this paper. The effects of temperature, time and extent of stretching and shrinkage temperature and time have been reported. Based on the above data, the optimized conditions in terms of high heat shrinkage and low amnesia rating have been evaluated. Influence of radiation doses (0-500 kGy), multifunctional sensitizer levels (ditri methylol propane tetraacrylate, DTMPTA), and blend proportions on heat shrink ability has been explained with the help of gel fraction and X-ray data. With the increase in radiation dose, gel fraction increases, which in turn gives rise to low values of heat shrinkage and amnesia rating. At a constant radiation dose and blend ratio, percent heat shrinkage is found to decrease with increase in DTMPTA level. Gel content increases with the increase in EVA content of the blend at a constant radiation dose and monomer level, giving rise to decrease in heat shrink ability. Heat shrinkage increases with the increase in percent crystallinity, although the amnesia rating follows the reverse trend.

  15. Replacement of thermal column elastomeric gasket in pool type research reactors based on ageing and radiation degradation

    International Nuclear Information System (INIS)

    Garai, S.K.

    2006-01-01

    Pool type research reactors are designed with Thermal column facilities to irradiate samples at different flux levels of thermal neutrons. The sealing of demineralised pool water between stainless steel lined pool wall and the Aluminium Thermal column plate is achieved by an elastomeric gasket. The gasket joint is subjected to pool water temperature ranging from 25degC to 45degC and radiation field of the order of 104 -106 R/hr. The gasket loses its sealing properties due to ageing and radiation degradation after a few years, leading to the leakage and loss of the pool water. Though degradation of the gasket is, generally, predictable, some amount of uncertainty always remains in the leakage rate. The paper describes the study of a few elastomers in radiation environment and replacement of the Thermal column gasket of a swimming pool type research reactor. It includes the details of features like planning and scheduling, the actual sequential execution of the job, various problems encountered and corrective measures applied, engineering and radiological safety measures adopted, development of remote tools, disassembly and reassembly procedure and finally satisfactory completion of the site job in high radiation environment with minimum time and man rem consumption. (author)

  16. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  17. Recommended Practice for Patch Management of Control Systems

    Energy Technology Data Exchange (ETDEWEB)

    Steven Tom; Dale Christiansen; Dan Berrett

    2008-12-01

    A key component in protecting a nation’s critical infrastructure and key resources is the security of control systems. The term industrial control system refers to supervisory control and data acquisition, process control, distributed control, and any other systems that control, monitor, and manage the nation’s critical infrastructure. Critical Infrastructure and Key Resources (CIKR) consists of electric power generators, transmission systems, transportation systems, dam and water systems, communication systems, chemical and petroleum systems, and other critical systems that cannot tolerate sudden interruptions in service. Simply stated, a control system gathers information and then performs a function based on its established parameters and the information it receives. The patch management of industrial control systems software used in CIKR is inconsistent at best and nonexistent at worst. Patches are important to resolve security vulnerabilities and functional issues. This report recommends patch management practices for consideration and deployment by industrial control systems owners.

  18. Image superresolution of cytology images using wavelet based patch search

    Science.gov (United States)

    Vargas, Carlos; García-Arteaga, Juan D.; Romero, Eduardo

    2015-01-01

    Telecytology is a new research area that holds the potential of significantly reducing the number of deaths due to cervical cancer in developing countries. This work presents a novel super-resolution technique that couples high and low frequency information in order to reduce the bandwidth consumption of cervical image transmission. The proposed approach starts by decomposing into wavelets the high resolution images and transmitting only the lower frequency coefficients. The transmitted coefficients are used to reconstruct an image of the original size. Additional details are added by iteratively replacing patches of the wavelet reconstructed image with equivalent high resolution patches from a previously acquired image database. Finally, the original transmitted low frequency coefficients are used to correct the final image. Results show a higher signal to noise ratio in the proposed method over simply discarding high frequency wavelet coefficients or replacing directly down-sampled patches from the image-database.

  19. Retrospective evaluation of the consequence of alleged patch test sensitization

    DEFF Research Database (Denmark)

    Jensen, Charlotte D; Paulsen, Evy; Andersen, Klaus E

    2006-01-01

    The risk of actively sensitizing a patient in connection with diagnostic patch tests exists. This risk, however, is extremely low, especially from standard allergens, and if the test is carried out according to internationally accepted guidelines. This retrospective study investigates the clinical...... or available for the follow-up investigation and 3 patients were not traceable. Among the 14 remaining patients 1 had a reaction to gold sodium thiosulphate, which was assessed to be a persistent reaction and not a late reaction, and in 2 patients a clear relevance for the late reacting allergen was found....... For the remaining 11 patients we could not rule out that they were patch test sensitized, and they were investigated further. 1 was diseased and 10 were interviewed regarding the possible consequences of the alleged patch test sensitization. 9 had not experienced any dermatitis problems, and 1 could not exclude...

  20. Patch models and their applications to multivehicle command and control.

    Science.gov (United States)

    Rao, Venkatesh G; D'Andrea, Raffaello

    2007-06-01

    We introduce patch models, a computational modeling formalism for multivehicle combat domains, based on spatiotemporal abstraction methods developed in the computer science community. The framework yields models that are expressive enough to accommodate nontrivial controlled vehicle dynamics while being within the representational capabilities of common artificial intelligence techniques used in the construction of autonomous systems. The framework allows several key design requirements of next-generation network-centric command and control systems, such as maintenance of shared situation awareness, to be achieved. Major features include support for multiple situation models at each decision node and rapid mission plan adaptation. We describe the formal specification of patch models and our prototype implementation, i.e., Patchworks. The capabilities of patch models are validated through a combat mission simulation in Patchworks, which involves two defending teams protecting a camp from an enemy attacking team.

  1. Investigation of contact allergy to dental materials by patch testing

    Directory of Open Access Journals (Sweden)

    Reena Rai

    2014-01-01

    Full Text Available Background: Dental products are widely used by patients and dental personnel alike and may cause problems for both. Dental materials could cause contact allergy with varying manifestations such as burning, pain, stomatitis, cheilitis, ulcers, lichenoid reactions localized to the oral mucosa in patients, and hand dermatitis in dental personnel. Patch testing with the dental series comprising commonly used materials can be used to detect contact allergies to dental materials. Aim: This study aimed to identify contact allergy among patients who have oral mucosal lesions after dental treatment and among dental personnel who came in contact with these materials. Materials and Methods: Twenty patients who had undergone dental procedures with symptoms of oral lichen planus, oral stomatitis, burning mouth, and recurrent aphthosis, were included in the study. Dental personnel with history of hand dermatitis were also included in the study. Patch testing was performed using Chemotechnique Dental Series and results interpreted as recommended by the International Contact Dermatitis Research Group (ICDRG. Results: Out of 13 patients who had undergone dental treatment/with oral symptoms, six patients with stomatitis, lichenoid lesions, and oral ulcers showed positive patch tests to a variety of dental materials, seven patients with ulcers had negative patch tests, seven dental personnel with hand dermatitis showed multiple allergies to various dental materials, and most had multiple positivities. Conclusion: The patch test is a useful, simple, noninvasive method to detect contact allergies among patients and among dental personnel dealing with these products. Long term studies are necessary to establish the relevance of these positive patch tests by eliminating the allergic substances, identifying clinical improvement, and substituting with nonallergenic materials.

  2. U Patch Antenna for RFID and Wireless Applications

    International Nuclear Information System (INIS)

    Abi Saad, R.; Melhem, Z.; Nader, C.; Zaatar, Y.; Zaouk, D.

    2011-01-01

    in this paper, we propose a new multi-band patch antenna structure for embedded RFID (Radio Frequency Identification) readers and wireless communications. The proposed antenna is a dual band microstrip patch antenna using U-slot geometry. The operating frequencies of the proposed antenna are chosen as 2.4 and 0.9 (GHz), obtained by optimizing the physical dimensions of the U-slot. Several parameters have been investigated using Ansoft Designer software. The antenna is fed through a quarter wavelength transformer for impedance matching. An additional layer of alumina is added above the surface of the conductors to increase the performance of the antenna. (author)

  3. Novel Wideband Metallic Patch Antennas with Low Profile

    Directory of Open Access Journals (Sweden)

    Zhong-Xiang Zhang

    2017-01-01

    Full Text Available Two planar metallic patch (MP antennas with low profiles are investigated and compared in this paper. The MP of each antenna consists of metallic patch cells and it is centrally fed by a rectangular slot. Two modes with close resonance frequencies are excited, providing a quite wide bandwidth. The antenna principle is explained clearly through a parametric study. Simulated and measured results show that the MP antennas with profile of 0.06λ0 can obtain a 10 dB impedance bandwidth of ~32% and an average gain of ~10 dBi.

  4. Black-hole excision with multiple grid patches

    Energy Technology Data Exchange (ETDEWEB)

    Thornburg, Jonathan [Max-Planck-Institut fuer Gravitationsphysik, Albert-Einstein-Institut, Am Muehlenberg 1, D-14476 Golm (Germany)

    2004-08-07

    When using black-hole excision to numerically evolve a black-hole spacetime with no continuous symmetries, most 3 + 1 finite differencing codes use a Cartesian grid. It is difficult to do excision on such a grid because the natural r = constant excision surface must be approximated either by a very different shape such as a contained cube, or by an irregular and non-smooth 'LEGO{sup 1} sphere' which may introduce numerical instabilities into the evolution. In this paper I describe an alternate scheme which uses multiple {l_brace}r x (angular coordinates){r_brace} grid patches, each patch using a different (nonsingular) choice of angular coordinates. This allows excision on a smooth r = constant 2-sphere. I discuss the key design choices in such a multiple-patch scheme, including the choice of ghost-zone versus internal-boundary treatment of the interpatch boundaries (I use a ghost-zone scheme), the number and shape of the patches (I use a 6-patch 'inflated-cube' scheme), the details of how the ghost zones are 'synchronized' by interpolation from neighbouring patches, the tensor basis for the Einstein equations in each patch, and the handling of non-tensor field variables such as the BSSN {gamma}-tilde{sup i} (I use a scheme which requires ghost zones which are twice as wide for the BSSN conformal factor {phi} as for {gamma}-tilde{sup i} and the other BSSN field variables). I present sample numerical results from a prototype implementation of this scheme. This code simulates the time evolution of the (asymptotically flat) spacetime around a single (excised) black hole, using fourth-order finite differencing in space and time. Using Kerr initial data with J/m{sup 2} = 0.6, I present evolutions to t {approx}> 1500m. The lifetime of these evolutions appears to be limited only by outer boundary instabilities, not by any excision instabilities or by any problems inherent to the multiple-patch scheme.

  5. Rebootless Linux Kernel Patching with Ksplice Uptrack at BNL

    International Nuclear Information System (INIS)

    Hollowell, Christopher; Pryor, James; Smith, Jason

    2012-01-01

    Ksplice/Oracle Uptrack is a software tool and update subscription service which allows system administrators to apply security and bug fix patches to the Linux kernel running on servers/workstations without rebooting them. The RHIC/ATLAS Computing Facility (RACF) at Brookhaven National Laboratory (BNL) has deployed Uptrack on nearly 2,000 hosts running Scientific Linux and Red Hat Enterprise Linux. The use of this software has minimized downtime, and increased our security posture. In this paper, we provide an overview of Ksplice's rebootless kernel patch creation/insertion mechanism, and our experiences with Uptrack.

  6. Transparent biocompatible sensor patches for touch sensitive prosthetic limbs

    KAUST Repository

    Nag, Anindya

    2016-12-26

    The paper presents the fabrication of transparent, flexible sensor patches developed using a casting technique with polydimethylsiloxane (PDMS) as substrate and a nanocomposite of carbon nanotubes (CNTs) and PDMS as interdigital electrodes. The electrodes act as strain sensitive capacitor. The prototypes were used as touch sensitive sensors attached to the limbs. Experiments results show the sensitivity of the patches towards tactile sensing. The results are very promising and can play a key role in the development of a cost efficient sensing system attached to prosthetic limbs.

  7. Transparent biocompatible sensor patches for touch sensitive prosthetic limbs

    KAUST Repository

    Nag, Anindya; Mukhopadhyay, Subhas; Kosel, Jü rgen

    2016-01-01

    The paper presents the fabrication of transparent, flexible sensor patches developed using a casting technique with polydimethylsiloxane (PDMS) as substrate and a nanocomposite of carbon nanotubes (CNTs) and PDMS as interdigital electrodes. The electrodes act as strain sensitive capacitor. The prototypes were used as touch sensitive sensors attached to the limbs. Experiments results show the sensitivity of the patches towards tactile sensing. The results are very promising and can play a key role in the development of a cost efficient sensing system attached to prosthetic limbs.

  8. Effects of patch size on feeding associations in muriquis (Brachyteles arachnoides).

    Science.gov (United States)

    Strier, K B

    1989-01-01

    Data were collected on one group of muriquis, or woolly spider monkeys (Brachyteles arachnoides) during a 14-month study at Fazenda Montes Claros, Minas Gerais, Brazil to examine the effects of food patch size on muriqui feeding associations. Muriqui food patches were larger than expected from the availability of patch sizes in the forest; fruit patches were significantly larger than leaf patches. Feeding aggregate size, the maximum number of simultaneous occupants, and patch occupancy time were positively related to the size of fruit patches. However, a greater number of individuals fed at leaf sources than expected from the size of these patches. Adult females tended to feed alone in patches more often than males, whereas males tended to feed in single-sexed groups more often than females. Yet in neither case were these differences statistically significant.

  9. Necrotic patches affect Acropora palmata (Scleractinia: Acroporidae) in the Mexican Caribbean.

    Science.gov (United States)

    Rodríguez-Martínez, R E; Banaszak, A T; Jordán-Dahlgren, E

    2001-12-05

    An outbreak of necrotic patches was observed affecting Acropora palmata in the Mexican Caribbean in the summer of 1999. This study documents the tissue loss produced by these patches. Following a marked initial increase in the number of patches, there was a decrease in the appearance of new patches but the size of the patches increased throughout the study. In some cases patches expanded but in most cases they enlarged due to fusion of 2 or more patches. Patches recovered but not sufficiently to overcome damage in most colonies surveyed. Percentage tissue loss does not appear to be directly related to temperature but may be related to a combination of factors associated with prolonged summer doldrum-like conditions. The necrotic patch syndrome can have a substantial impact in tissue loss in affected A. palmata colonies.

  10. Flow characterization and patch clamp dose responses using jet microfluidics in a tubeless microfluidic device.

    Science.gov (United States)

    Resto, Pedro J; Bhat, Abhishek; Stava, Eric; Lor, Chong; Merriam, Elliot; Diaz-Rivera, Ruben E; Pearce, Robert; Blick, Robert; Williams, Justin C

    2017-11-01

    Surface tension passive pumping is a way to actuate flow without the need for pumps, tubing or valves by using the pressure inside small drop to move liquid via a microfluidic channel. These types of tubeless devices have typically been used in cell biology. Herein we present the use of tubeless devices as a fluid exchange platform for patch clamp electrophysiology. Inertia from high-speed droplets and jets is used to create flow and perform on-the-fly mixing of solutions. These are then flowed over GABA transfected HEK cells under patch in order to perform a dose response analysis. TIRF imaging and electrical recordings are used to study the fluid exchange properties of the microfluidic device, resulting in 0-90% fluid exchange times of hundreds of milliseconds. COMSOL is used to model flow and fluid exchange within the device. Patch-clamping experiments show the ability to use high-speed passive pumping and its derivatives for studying peak dose responses, but not for studying ion channel kinetics. Our system results in fluid exchange times slower than when using a standard 12-barrel application system and is not as stable as traditional methods, but it offers a new platform with added functionality. Surface tension passive pumping and tubeless devices can be used in a limited fashion for electrophysiology. Users may obtain peak dose responses but the system, in its current form, is not capable of fluid exchange fast enough to study the kinetics of most ion channels. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A layer-wise MITC9 finite element for the free-vibration analysis of plates with piezo-patches

    Directory of Open Access Journals (Sweden)

    Maria Cinefra

    2015-04-01

    Full Text Available The present article considers the free-vibration analysis of plate structures with piezoelectric patches by means of a plate finite element with variable through-the-thickness layer-wise kinematic. The refined models used are derived from Carrera’s Unified Formulation (CUF and they permit the vibration modes along the thickness to be accurately described. The finite-element method is employed and the plate element implemented has nine nodes, and the mixed interpolation of tensorial component (MITC method is used to contrast the membrane and shear locking phenomenon. The related governing equations are derived from the principle of virtual displacement, extended to the analysis of electromechanical problems. An isotropic plate with piezoelectric patches is analyzed, with clamped-free boundary conditions and subjected to open- and short-circuit configurations. The results, obtained with different theories, are compared with the higher-order type solutions given in the literature. The conclusion is reached that the plate element based on the CUF is more suitable and efficient compared to the classical models in the study of multilayered structures embedding piezo-patches.

  12. Multi-patch matching for person re-identification

    Science.gov (United States)

    Labidi, Hocine; Luo, Sen-Lin; Boubekeur, Mohamed B.; Benlefki, Tarek

    2015-08-01

    Recognizing a target object across non-overlapping distributed cameras is known in the computer vision community as the problem of person re-identification. In this paper, a multi-patch matching method for person reidentification is presented. Starting from the assumption that: the appearance (clothes) of a person does not change during the time of passing in different cameras field of view , which means the regions with the same color in target image will be identical while crossing cameras. First, we extract distinctive features in the training procedure, where each image target is devised into small patches, the SIFT features and LAB color histograms are computed for each patch. Then we use the KNN approach to detect group of patches with high similarity in the target image and then we use a bi-directional weighted group matching mechanism for the re-identification. Experiments on a challenging VIPeR dataset show that the performances of the proposed method outperform several baselines and state of the art approaches.

  13. Microstrip patch antenna for simultaneous strain and temperature sensing

    Science.gov (United States)

    Mbanya Tchafa, F.; Huang, H.

    2018-06-01

    A patch antenna, consisting of a radiation patch, a dielectric substrate, and a ground plane, resonates at distinct fundamental frequencies that depend on the substrate dielectric constant and the dimensions of the radiation patch. Since these parameters change with the applied strain and temperature, this study investigates simultaneous strain and temperature sensing using a single antenna that has two fundamental resonant frequencies. The theoretical relationship between the antenna resonant frequency shifts, the temperature, and the applied strain was first established to guide the selection of the dielectric substrate, based on which an antenna sensor with a rectangular radiation patch was designed and fabricated. A tensile test specimen instrumented with the antenna sensor was subjected to thermo-mechanical tests. Experiment results validated the theoretical predictions that the normalized antenna resonant frequency shifts are linearly proportional to the applied strain and temperature changes. An inverse method was developed to determine the strain and temperature changes from the normalized antenna resonant frequency shifts, yielding measurement uncertainty of 0.4 °C and 17.22 μ \\varepsilon for temperature and strain measurement, respectively.

  14. Assessing the Army’s Software Patch Management Process

    Science.gov (United States)

    2016-03-04

    software maker or to antivirus vendors (Zetter, 2014). Fixing such a vulnerability within the zero-day period requires teamwork across multiple...Assessing the Army’s Software Patch Management Process Benjamin Alan Pryor March 4, 2016 PUBLISHED...19 Commercial-Off-the-Shelf Software

  15. Patch testing of 490 patients in Hong Kong.

    Science.gov (United States)

    Lee, T Y; Lam, T H

    1996-07-01

    Patch testing, using European standard allergens and suspected causative substances brought in by patients, was carried out in 490 patients with eczema in Hong Kong and 437 completed the test. Before patch testing, 244, 141 and 105 patients were diagnosed as having contact dermatitis, endogenous eczema and unclassified eczema, respectively. After patch testing, the diagnosis of the causal agent was changed in 54 contact dermatitis patients, and 18% of endogenous eczema patients and 34% of unclassified eczema patients were re-diagnosed as contact dermatitis. In the patients with a final diagnosis of contact dermatitis, 19.5% were positive to fragrance mix, followed by nickel sulfate (16.4%) and cobalt chloride (11.3%). The commonest causative agents for contact dermatitis were soap or detergent (22.0%) and traditional Chinese medicine (17.3%); the latter was a more common cause of contact dermatitis than Western medicine (9.0%) or metals (13.4%). The prevalence of allergic reaction to fragrance in Hong Kong was higher than among Chinese in Beijing, Shanghai, Taipei or Singapore (78% ethnic Chinese). Dermatologists should have a high index of suspicion about traditional medications and should patch test with the suspected substance when patients give a history of use.

  16. SIMULATED CHARACTERISTICS OF PATCH ANTENNA LOADED WITH SRRs

    OpenAIRE

    Debasis Mishra; G. Arun Kumar; D. R. Poddar; R. K. Mishra

    2010-01-01

    This article investigates, from electromagnetic simulation, the effects on gain and efficiency of a patch antenna loaded with split ring resonators. It is observed that it leads to lowering of resonant frequency; some mismatch resulting in a slight degradation of the impedance bandwidth and improvement of gain and efficiency.

  17. A Fully Inkjet Printed 3D Honeycomb Inspired Patch Antenna

    KAUST Repository

    McKerricher, Garret; Titterington, Don; Shamim, Atif

    2015-01-01

    by inkjet printing in this work. This is the first demonstration of a fully 3D Multijet printing process with integrated polymer and metal. A 2.4 GHz patch antenna is successfully fabricated with good performance proving the viability of the process

  18. Wearable Inset-Fed FR4 Microstrip Patch Antenna Design

    Science.gov (United States)

    Zaini, S. R. Mohd; Rani, K. N. Abdul

    2018-03-01

    This project proposes the design of a wireless body area network (WBAN) microstrip patch antenna covered by the jeans fabric as the outer layer operating at the center frequency, fc of 2.40 GHz. Precisely, the microstrip patch antenna with the inset-fed edge technique is designed and simulated systematically by using the Keysight Advanced Design System (ADS) software where the FR4 board with the dielectric constant, ɛr of 4.70, dissipation factor or loss tangent, tan δ of 0.02 and height, h of 1.60 mm is the chosen dielectric substrate. The wearable microstrip patch antenna design is then fabricated using the FR4 printed circuit board (PCB) material, hidden inside the jeans fabric, and attached to clothing, such as a jacket accordingly. Simulation and fabrication measurement results show that the designed microstrip patch antenna characteristics can be applied significantly within the industrial, scientific, and medical (ISM) radio band, which is at fc = 2.40 GHz.

  19. Constraint Patch Matching for Faster Person Re-identification

    DEFF Research Database (Denmark)

    Lejbølle, Aske Rasch; Nasrollahi, Kamal; Moeslund, Thomas B.

    2017-01-01

    In person re-identification, it is of great importance toextract very discriminative features in order to distinguishbetween images of different persons captured in differentcamera views. Features can be extracted globally from theentire or parts of the image, or locally from patches. Inaddition......36ms to compute per person....

  20. Diagnosis of Broiler Livers by Classifying Image Patches

    DEFF Research Database (Denmark)

    Jørgensen, Anders; Fagertun, Jens; Moeslund, Thomas B.

    2017-01-01

    The manual health inspection are becoming the bottleneck at poultry processing plants. We present a computer vision method for automatic diagnosis of broiler livers. The non-rigid livers, of varying shape and sizes, are classified in patches by a convolutional neural network, outputting maps...

  1. The sensitivity of patch test in patients with psoriasis

    Directory of Open Access Journals (Sweden)

    Yavuz Yeşilova

    2010-09-01

    Full Text Available Objectives: Allergic diseases play an important role in the natural course of psoriasis. Atopic sensitization and con-tact dermatitis are common in patients with psoriasis. Since the symptoms are prolonged in patients who are resistant to therapy and exposure to itchy and external factors are common among these patients, the effects of contact aller-gens on triggering psoriasis are investigated. Contact allergens have an important role in activation and remission of psoriasis. We aimed to investigate contact sensitization rates in patients with psoriasis in the study.Material and Methods: Contact sensitization was investigated with the application of European standard series in twenty patients with psoriasis, twenty patients with contact dermatitis, and twenty healthy persons. Results: Among the whole study cases, positivity rate of patch test against one allergen at least was 25%. rate of patch test was 25% in patients with psoriasis, 35% in patients with contact dermatitis, and 15% in healthy persons. There were no significant differences between the groups according to sensitization to one or more allergens (p>0.05. There were no significant difference in clinical subgroup of psoriatic patients according to contact sensitiza-tion (p>0.05. The allergens in patients with psoriasis on patch test were as the followings: phenyldiamine, potassium dichromat, nickel, and cobalt.Conclusion: We think that the patch test has a major role in the diagnosis and elimination of allergens in patients with the chronic and resistant diseases and palmoplantar and flexural psoriasis.

  2. Evaluation of UAV imagery for mapping Silybum marianum weed patches

    Science.gov (United States)

    The invasive weed, milk thistle (Silybum marianum), has the tendency to grow in patches. In order to perform site-specific weed management, determining the spatial distribution of weeds is important for its eradication. Remote sensing has been used to perform species discrimination, and it offers pr...

  3. The Jejunal Serosal Patch Procedure: A Successful Technique for ...

    African Journals Online (AJOL)

    Background: The selection of the most appropriate technique for the repair of peptic ulcer perforations, especially when the initial attempt of closure has failed have been the concern of many surgeons. Since the experimental report regarding the jejunal serosal patch procedure by Koboldin in 1963, authors have reported its ...

  4. Ruptured peroneal aneurysm after infrapopliteal prosthetic bypass with Taylor patch

    Directory of Open Access Journals (Sweden)

    Florian Enzmann

    Full Text Available Introduction: A 45-year-old mailman underwent an implantation of a femoro-peroneal polytetrafluoroethylene (PTFE bypass with a distal Taylor patch six years prior to admission after two failed autologous reconstructions and extensive fasciotomy. The initial pathology was an acute ischemia due to popliteal entrapment with subsequent popliteal thrombectomy. Report: The patient was examined because of pain, reduction of walking distance and development of a palpable mass at the medial fasciotomy site. A 6-cm pseudoaneurysm with complete disruption of the suture line of the vein patch was discovered and resected. Arterial continuity with a vein interposition graft was established using non-reversed cephalic vein. Conclusion: The etiology of the aneurysm is not entirely clear. One may argue that the fourth revascularization could have been performed with an arm vein instead of a prosthetic graft with the probability of a better long term patency in a young patient. 15 months after the procedure the bypass is patent and the patient is without any symptoms. This complication of a Taylor patch has not been reported before. Keywords: Taylor patch, Pseudoaneurysm, Infrapopliteal bypass

  5. Designing and testing a wearable, wireless fNIRS patch.

    Science.gov (United States)

    Abtahi, Mohammadreza; Cay, Gozde; Saikia, Manob Jyoti; Mankodiya, Kunal

    2016-08-01

    Optical brain monitoring using near infrared (NIR) light has got a lot of attention in order to study the complexity of the brain due to several advantages as oppose to other methods such as EEG, fMRI and PET. There are a few commercially available functional NIR spectroscopy (fNIRS) brain monitoring systems, but they are still non-wearable and pose difficulties in scanning the brain while the participants are in motion. In this work, we present our endeavors to design and test a low-cost, wireless fNIRS patch using NIR light sources at wavelengths of 770 and 830nm, photodetectors and a microcontroller to trigger the light sources, read photodetector's output and transfer data wirelessly (via Bluetooth) to a smart-phone. The patch is essentially a 3-D printed wearable system, recording and displaying the brain hemodynamic responses on smartphone, also eliminates the need for complicated wiring of the electrodes. We have performed rigorous lab experiments on the presented system for its functionality. In a proof of concept experiment, the patch detected the NIR absorption on the arm. Another experiment revealed that the patch's battery could last up to several hours with continuous fNIRS recording with and without wireless data transfer.

  6. Isogeometric shape optimization of photonic crystals via Coons patches

    DEFF Research Database (Denmark)

    Qian, Xiaoping; Sigmund, Ole

    2011-01-01

    In this paper, we present an approach that extends isogeometric shape optimization from optimization of rectangular-like NURBS patches to the optimization of topologically complex geometries. We have successfully applied this approach in designing photonic crystals where complex geometries have...

  7. Performance of shcc with bacteria for concrete patch repair

    NARCIS (Netherlands)

    Sierra Beltran, M.G.; Jonkers, H.M.; Schlangen, E.

    2014-01-01

    The overall performance of concrete patch repair systems depends on the durability of and compatibility between the concrete substrate and the repair material. This paper investigates the performance of a new type of SHCC material with embedded bacteria as a repair material. The bacteria are a

  8. A multiresolution remeshed Vortex-In-Cell algorithm using patches

    DEFF Research Database (Denmark)

    Rasmussen, Johannes Tophøj; Cottet, Georges-Henri; Walther, Jens Honore

    2011-01-01

    We present a novel multiresolution Vortex-In-Cell algorithm using patches of varying resolution. The Poisson equation relating the fluid vorticity and velocity is solved using Fast Fourier Transforms subject to free space boundary conditions. Solid boundaries are implemented using the semi...

  9. Interactive object modelling based on piecewise planar surface patches.

    Science.gov (United States)

    Prankl, Johann; Zillich, Michael; Vincze, Markus

    2013-06-01

    Detecting elements such as planes in 3D is essential to describe objects for applications such as robotics and augmented reality. While plane estimation is well studied, table-top scenes exhibit a large number of planes and methods often lock onto a dominant plane or do not estimate 3D object structure but only homographies of individual planes. In this paper we introduce MDL to the problem of incrementally detecting multiple planar patches in a scene using tracked interest points in image sequences. Planar patches are reconstructed and stored in a keyframe-based graph structure. In case different motions occur, separate object hypotheses are modelled from currently visible patches and patches seen in previous frames. We evaluate our approach on a standard data set published by the Visual Geometry Group at the University of Oxford [24] and on our own data set containing table-top scenes. Results indicate that our approach significantly improves over the state-of-the-art algorithms.

  10. Smooth surfaces from bilinear patches: Discrete affine minimal surfaces

    KAUST Repository

    Käferböck, Florian

    2013-06-01

    Motivated by applications in freeform architecture, we study surfaces which are composed of smoothly joined bilinear patches. These surfaces turn out to be discrete versions of negatively curved affine minimal surfaces and share many properties with their classical smooth counterparts. We present computational design approaches and study special cases which should be interesting for the architectural application. 2013 Elsevier B.V.

  11. Temporary patching of damaged UF{sub 6} cylinders

    Energy Technology Data Exchange (ETDEWEB)

    Cardenas, A.L. [Martin Marietta Energy Systems, Inc., OH (United States)

    1991-12-31

    Patching techniques based on application of epoxy resins have been developed for temporarily repairing UF{sub 6} cylinders which have sustained relatively minor damage and must be safely emptied. The method is considerably faster and simpler than metallurgical weld repairs. Laboratory tests, detailed operational procedures, and case histories of experience at the Portsmouth Gaseous Diffusion Plant are described.

  12. Our experience with atopy patch tests with aeroallergens.

    Science.gov (United States)

    Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava

    2013-01-01

    Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.

  13. An improved broadband E patch microstrip antenna for wireless communications

    Science.gov (United States)

    Bzeih, Amer; Chahine, Soubhi Abou; Kabalan, Karim Y.; El-Hajj, Ali; Chehab, Ali

    2007-12-01

    A broadband probe-fed microstrip antenna with E-shaped patch on a single-layer air substrate is investigated. Bandwidth enhancement of the antenna is achieved by inserting two parallel slots into its radiating patch. The effects of the antenna parameters are analyzed, and their optimal values for broadband operation are obtained. The design parameters are formulated as a function of the center frequency, and the empirical equations are validated by simulation. A 51.5% enhanced E patch antenna for modern wireless communications (Personal Communications Service, Digital Cellular System, Universal Mobile Telecommunications System, Wireless Local Area Network 802.11 b/g, and Bluetooth) is designed, simulated, fabricated, and measured. A comparison between simulated and measured results is presented, and it showed satisfactory agreement. Moreover, the effect of incorporating more parallel slots into the radiating patch is investigated. The antenna is designed and simulated for different scenarios (four slots, six slots, and eight slots), where a bandwidth of 57% is achieved in the eight-slot design.

  14. Photopatch and UV-irradiated patch testing in photosensitive dermatitis

    Directory of Open Access Journals (Sweden)

    Reena Rai

    2016-01-01

    Full Text Available Background: The photopatch test is used to detect photoallergic reactions to various antigens such as sunscreens and drugs. Photosensitive dermatitis can be caused due to antigens like parthenium, fragrances, rubbers and metals. The photopatch test does not contain these antigens. Therefore, the Indian Standard Series (ISS along with the Standard photopatch series from Chemotechnique Diagnostics, Sweden was used to detect light induced antigens. Aim: To detect light induced antigens in patients with photosensitive dermatitis. Methods: This study was done in a descriptive, observer blinded manner. Photopatch test and ISS were applied in duplicate on the patient's back by the standard method. After 24 hours, readings were recorded according to ICDRG criteria. One side was closed and other side irradiated with 14 J/cm2 of UVA and a second set of readings were recorded after 48 hrs. Result: The highest positivity was obtained with parthenium, with 18 out of 35 (51% patients showing a positive patch test reaction with both photoallergic contact dermatitis and photoaggravation. Four patients (11% showed positive patch test reaction suggestive of contact dermatitis to potassium dichromate and fragrance mix. Six patients had contact dermatitis to numerous antigens such as nickel, cobalt, chinoform and para-phenylenediamine. None of these patients showed photoaggravation on patch testing. Conclusion: Parthenium was found to cause photoallergy, contact dermatitis with photoaggravation and contact allergy. Hence, photopatch test and UV irradiated patch test can be an important tool to detect light induced antigens in patients with photosensitive dermatitis.

  15. Patch testing for food-associated allergies in orofacial granulomatosis.

    LENUS (Irish Health Repository)

    Fitzpatrick, Laura

    2011-01-01

    Food-associated allergies, especially to benzoates and cinnamon-related compounds, have been associated with orofacial granulomatosis and both standard and urticarial patch testing have been used to detect such allergies. Elimination diets have also been shown to be effective in some patients.

  16. Limonene hydroperoxide analogues show specific patch test reactions.

    Science.gov (United States)

    Christensson, Johanna Bråred; Hellsén, Staffan; Börje, Anna; Karlberg, Ann-Therese

    2014-05-01

    The fragrance terpene R-limonene is a very weak sensitizer, but forms allergenic oxidation products upon contact with air. The primary oxidation products of oxidized limonene, the hydroperoxides, have an important impact on the sensitizing potency of the oxidation mixture. One analogue, limonene-1-hydroperoxide, was experimentally shown to be a significantly more potent sensitizer than limonene-2-hydroperoxide in the local lymph node assay with non-pooled lymph nodes. To investigate the pattern of reactivity among consecutive dermatitis patients to two structurally closely related limonene hydroperoxides, limonene-1-hydroperoxide and limonene-2-hydroperoxide. Limonene-1-hydroperoxide, limonene-2-hydroperoxide, at 0.5% in petrolatum, and oxidized limonene 3.0% pet. were tested in 763 consecutive dermatitis patients. Of the tested materials, limonene-1-hydroperoxide gave most reactions, with 2.4% of the patients showing positive patch test reactions. Limonene-2-hydroperoxide and oxidized R-limonene gave 1.7% and 1.2% positive patch test reactions, respectively. Concomitant positive patch test reactions to other fragrance markers in the baseline series were frequently noted. The results are in accordance with the experimental studies, as limonene-1-hydroperoxide gave more positive patch test reactions in the tested patients than limonene-2-hydroperoxide. Furthermore, the results support the specificity of the allergenic activity of the limonene hydroperoxide analogues and the importance of oxidized limonene as a cause of contact allergy. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Diagnostic accuracy of patch test in children with food allergy.

    Science.gov (United States)

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Patched Green's function techniques for two-dimensional systems

    DEFF Research Database (Denmark)

    Settnes, Mikkel; Power, Stephen; Lin, Jun

    2015-01-01

    We present a numerically efficient technique to evaluate the Green's function for extended two-dimensional systems without relying on periodic boundary conditions. Different regions of interest, or “patches,” are connected using self-energy terms which encode the information of the extended parts...

  19. Variation in aluminium patch test reactivity over time.

    Science.gov (United States)

    Siemund, Ingrid; Mowitz, Martin; Zimerson, Erik; Bruze, Magnus; Hindsén, Monica

    2017-11-01

    Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting. To investigate possible variations in patch test reactivity to aluminium over time. Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months. Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared. The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Study of LCP based flexible patch antenna array

    KAUST Repository

    Ghaffar, Farhan A.; Shamim, Atif; Roy, Langis

    2012-01-01

    Wrapping of a two element LCP based patch antenna array is studied in this work. For the first time, the designed array is bent in both E and H planes to observe the effect on the radiation and impedance performance of the antenna. The 38 GHz

  1. Transdermal fentanyl matrix patches Matrifen and Durogesic DTrans are bioequivalent

    DEFF Research Database (Denmark)

    Kress, Hans G; Boss, Hildegard; Delvin, Thomas

    2010-01-01

    AIM: The pharmacokinetic profiles of the two commercially available transdermal fentanyl patches Matrifen (100 microg/h) and Durogesic DTrans (100 microg/h), used to manage severe chronic pain, were compared regarding their systemic exposure, rate of absorption, and safety. METHODS: Transdermal m...

  2. Satellite image based quantification of invasion and patch dynamics ...

    Indian Academy of Sciences (India)

    dynamics of mesquite (Prosopis juliflora) in Great Rann ... The present study was conducted in the Great Rann of Kachchh, part of Kachchh ... The process of Prosopis invasion shows high patch initiation, followed by .... formed by determining the percentage relationship .... poor women in northwestern India benefit from the.

  3. Patch Pd para Nih-Nik de Chico Mello

    Directory of Open Access Journals (Sweden)

    Gabriel Montechiari e Silva

    2014-12-01

    Full Text Available This Pure Data patch was commissioned by the Ensemble Nih-Nik for the premier of the homonymous 1993 piece by Brazilian composer Chico Mello at the SiMN 2014 + matrix14 on tour festival (Curitiba, Brazil.

  4. Characteristics of an autologous leukocyte and platelet-rich fibrin patch intended for the treatment of recalcitrant wounds

    DEFF Research Database (Denmark)

    Lundquist, Rasmus; Holmstrøm, Kim; Clausen, Christian

    2012-01-01

    We have investigated the physical, biochemical, and cellular properties of an autologous leukocyte and platelet-rich fibrin patch. This was generated in an automated device from a sample of a patient's blood at the point of care. Using microscopy, cell counting, enzyme-linked immunosorbent assay...... of chronic wound fluid. By comparison with traditional platelet-rich plasma, differences in immune components were found. The relevance of these findings was assessed by showing a mitogenic and migratory effect on cultured human dermal fibroblasts. Further, we showed that fibrocytes, a cell type important......, antibody arrays, and cell culture assays, we show that the patch is a three-layered membrane comprising a fibrin sheet, a layer of platelets, and a layer of leukocytes. Mean recovery of platelets from the donated blood was 98% (±95%CI 0.8%). Mean levels of platelet-derived growth factor AB, human...

  5. An investigation into UV light exposure as an experimental model for artificial aging on tensile strength and force delivery of elastomeric chain.

    Science.gov (United States)

    Wahab, Siti Waznah; Bister, Dirk; Sherriff, Martyn

    2014-02-01

    This study investigated the effect of ultraviolet type A light (UVA) exposure on the tensile properties of elastomeric chain. UVA light exposure was used as model for artificial aging, simulating prolonged storage of elastomeric chain. Tensile strength (n = 60) was measured after exposing Ormco, Forestadent and 3M chains to UVA light for 0, 2, 3, and 4 weeks. Force decay was measured (n = 60) using chain exposed for 5, 10, and 14 days. The chains were subsequently stretched at a constant distance and the resulting forces measured at 0, 1, 24 hours and 7, 14, 21, and 28 days. This test simulated a clinical scenario of pre-stretching and subsequent shortening of elastomeric chain. Tensile strength had statistically significant difference and was directly related to the duration of ultraviolet (UV) light exposure. Forestadent chain, which had the second highest value for the 'as received' product, showed the most consistent values over time with the lowest degradation. Ormco showed the lowest values for 'as received' as well as after UV exposure; 3M chain had the highest loss of tensile strength. Force decay was also significantly different. UV light exposure of 10 days or more appears to mark a 'watershed' between products: 3M had most survivors, Forestadent chain had some survivors, depending on the time the chain was stretched for. None of the Ormco product survived UV light exposure for more than 5 days. UVA light exposure may be used as a model for artificial aging as it reduces force delivery and tensile strength of exposed chains.

  6. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

    Science.gov (United States)

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing

    2014-03-01

    The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and at a breathing frequency of 30 breaths/min.

  7. Mating success of males with and without wing patch in Drosophila biarmipes.

    Science.gov (United States)

    Hegde, S N; Chethan, B K; Krishna, M S

    2005-10-01

    Some males of D. biarmipes--synonym of D. rajasekari and D. raychaudhuri have a black patch on the wing. The patch extends from the apical margin of wing to the third longitudinal vein. Field and laboratory studies have been carried out in D. biarmipes to study role of male's wing patch in mating success. The field study shows that nature favors D. biarmipes males with patch. Although males without patch mated, males with patch have higher mating success suggesting the role of wing patch during courtship. Further, among mating males, males with patch had longer wings than males without patch. During courtship, males with patch oriented and mated faster; performed courtship acts such as tapping, scissoring, vibration, licking and twist dance more times than males without patch in both competitive and non-competitive situations. The results indicate that there is a casual relationship between the presence of wing patch, mating speed and success. Also there is a correlation between presence of wing patch, size of the flies and mating success.

  8. Grassland Fire and Cattle Grazing Regulate Reptile and Amphibian Assembly Among Patches

    Science.gov (United States)

    Larson, Danelle M.

    2014-12-01

    Fire and grazing are common management schemes of grasslands globally and are potential drivers of reptilian and amphibian (herpetofauna) metacommunity dynamics. Few studies have assessed the impacts of fire and cattle grazing on herpetofauna assemblages in grasslands. A patch-burn grazing study at Osage Prairie, MO, USA in 2011-2012 created landscape patches with treatments of grazing, fire, and such legacies. Response variables were measured before and after the application of treatments, and I used robust-design occupancy modeling to estimate patch occupancy and detection rate within patches, and recolonization and extinction (i.e., dispersal) across patches. I conducted redundancy analysis and a permuted multivariate analysis of variance to determine if patch type and the associated environmental factors explained herpetofauna assemblage. Estimates for reptiles indicate that occupancy was seasonally constant in Control patches ( ψ ~ 0.5), but declined to ψ ~ 0.15 in patches following the applications of fire and grazing. Local extinctions for reptiles were higher in patches with fire or light grazing ( ɛ ~ 0.7) compared to the controls. For the riparian herpetofaunal community, patch type and grass height were important predictors of abundance; further, the turtles, lizards, snakes, and adult amphibians used different patch types. The aquatic amphibian community was predicted by watershed and in-stream characteristics, irrespective of fire or grazing. The varying responses from taxonomic groups demonstrate habitat partitioning across multiple patch types undergoing fire, cattle grazing, and legacy effects. Prairies will need an array of patch types to accommodate multiple herpetofauna species.

  9. Effectiveness of nickel-titanium springs vs elastomeric chains in orthodontic space closure: A systematic review and meta-analysis.

    Science.gov (United States)

    Mohammed, H; Rizk, M Z; Wafaie, K; Almuzian, M

    2018-02-01

    The aim of this study is to explore the effectiveness of nickel titanium closing springs (NiTi-CS) and elastomeric power chains (EPC) in orthodontic space closure and to assess the adverse periodontal effects, cost efficiency and patient-centred outcomes between both of these methods. An electronic search of online databases (Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, Scopus, LILACS and Web of Science), reference lists and grey literature as well as hand search were conducted without language restriction up to November/2017. Two authors blindly and in duplicate were involved in study selection, quality assessment and the extraction of data. Only randomized clinical trials (RCTs) were included. The quality of the studies was assessed using the Cochrane Collaboration's risk of bias tool. 95% confidence intervals and mean difference for continuous data were calculated. A meta-analysis that generated a random-effect model for the comparable outcomes was conducted, and heterogeneity was measured using I 2 statistic. Of 187 records, 4 RCTs met the criteria and were included in the quantitative synthesis featuring 290 test quadrants. Faster space closure with NiTi-CS was observed with a mean difference of (0.20 mm/month, 95% CI: 0.12 to 0.28). Loss of anchorage appears to be similar within both groups when synthesized qualitatively. With exception to anchorage loss, secondary outcomes could not be investigated in the included trials. There is a moderate quality of evidence suggesting a faster orthodontic space closure with the NiTi-CS when compared to EPC. A comparable amount of anchorage loss was observed regardless of the utilized method of space closure. Further high-quality RCTs with parallel-groups, reporting on the adverse effects and patient-centred values, are recommended. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Quasi-Static Behavior of Palm-Based Elastomeric Polyurethane: For Strengthening Application of Structures under Impulsive Loadings

    Directory of Open Access Journals (Sweden)

    H. M. Chandima Chathuranga Somarathna

    2016-05-01

    Full Text Available In recent years, attention has been focused on elastomeric polymers as a potential retrofitting material considering their capability in contributing towards the impact resistance of various structural elements. A comprehensive understanding of the behavior and the morphology of this material are essential to propose an effective and feasible alternative to existing structural strengthening and retrofitting materials. This article presents the findings obtained from a series of experimental investigations to characterize the physical, mechanical, chemical and thermal behavior of eight types of palm-based polyurethane (PU elastomers, which were synthesized from the reaction between palm kernel oil-based monoester polyol (PKO-p and 4,4-diphenylmethane diisocyanate (MDI with polyethylene glycol (PEG as the plasticizer via pre-polymerization. Fourier transform infrared (FT-IR spectroscopy analysis was conducted to examine the functional groups in PU systems. Mechanical and physical behavior was studied with focus on elongation, stresses, modulus, energy absorption and dissipation, and load dispersion capacities by conducting hardness, tensile, flexural, Izod impact, and differential scanning calorimetry tests. Experimental results suggest that the palm-based PU has positive effects as a strengthening and retrofitting material against dynamic impulsive loadings both in terms of energy absorption and dissipation, and load dispersion. In addition, among all PUs with different plasticizer contents, PU2 to PU8 (which contain 2% to 8% (w/w PEG with respect to PKO-p content show the best correlation with mechanical response under quasi-static conditions focusing on energy absorption and dissipation and load dispersion characteristics.

  11. Behavior of a New Elastomeric material used as polyolefinic geo membrane in waterproofing; Comportamiento de un nuevo material elastomerico utilizado como geomembrana poliolefinica en impermeabilizacion

    Energy Technology Data Exchange (ETDEWEB)

    Blanco, M.; Aguilar, E.; Vara, T. A; Soriano, J.; Garcia, F.; Castillo, F.

    2011-07-01

    Two decades ago that Balsas de Tenerife (BALTEN) and the Centro de Estudios y Experimentacion de Obras Publicas (CEDEX), in its experimental field of the south of the Tenerife Island have installed a series of materials to known their behaviour over time. These products among which was placed over a dozen years ago, on an elastomeric polyolefin. This work presents the performance of this synthetic geo membrane, focusing on the evolution in the time of the tensile properties static puncture, low temperature folding, dynamic impact, joint strength (shear and peeling test), optical microscopy of reflection nd scanning electron microscopy. (Author) 11 refs.

  12. Biological effects of brachytherapy using a {sup 32}P-patch on the skin of Sencar mice

    Energy Technology Data Exchange (ETDEWEB)

    Salgueiro, M.J. [Radioisotope Laboratory, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 Piso Bajo, 1113-Buenos Aires (Argentina)], E-mail: jsalgueiro@ffyb.uba.ar; Collia, N. [Radioisotope Laboratory, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 Piso Bajo, 1113-Buenos Aires (Argentina); Duran, H. [CONICET, San Martin (Argentina); School of Science and Technology, University of San Martin, San Martin (Argentina); Radiobiology Department, National Atomic Energy Commission (CNEA), Buenos Aires (Argentina); Palmieri, M. [CONICET, San Martin (Argentina); Biodiversity and Experimental Biology Department, School of Exact and Natural Sciences, University of Buenos Aires, Buenos Aires (Argentina); School of Science and Technology, University of San Martin, San Martin (Argentina); Medina, V. [Radioisotope Laboratory, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 Piso Bajo, 1113-Buenos Aires (Argentina); Ughetti, R.; Nicolini, J. [Research and Development Department, Laboratorios Bacon SAIC, Buenos Aires (Argentina); Zubillaga, M. [Radioisotope Laboratory, School of Pharmacy and Biochemistry, University of Buenos Aires, Junin 956 Piso Bajo, 1113-Buenos Aires (Argentina)

    2009-10-15

    In recent years, specially designed patches containing beta emitters have been developed for contact brachytherapy of skin lesions. The aim of the present work was to evaluate the biological effects of the {sup 32}P-patch on the skin of Sencar mice as a result of a brachytherapy treatment. For this purpose, a {sup 32}P-patch was prepared with Chromic {sup 32}P-phosphate and silicone and the classical model of two-stage skin carcinogenesis was reproduced in Sencar mice. Animals were divided in six groups. Four groups received the contact brachytherapy treatments using a scheme of a single session of 40 and 60 Gy (SD40 and SD60) and a scheme of two sessions of 40 and 60 Gy each (FD40 and FD60). The other two groups were used as controls of the single (CSD) and the fractionated (CFD) treatments. Radiation doses were estimated with equations derived from the MIRD DOSE scheme, and biologically effective doses (BED) were calculated according to equations derived from the linear-quadratic model. The endpoint to evaluate the treatments effects was tumor size after a follow-up period of 44 days. Finally, animals were sacrificed in order to get samples of all tumors for histological analysis and PCNA staining. Erythema, dermatitis and skin ulceration developed in almost all treated animals, but they gradually healed with regeneration of tissue during the follow-up period. Radiation effects on the skin of SD40, SD60, FD40 and FD60 showed a significant reduction of the tumor size with regard to controls, independently of the scheme and the radiation dose considered. PCNA staining scores of control groups were higher than for treated groups, independently of the scheme and the radiation dose considered. This radioactive {sup 32}P-silicone-patch which is easy to prepare and use in the treatment of skin diseases, seems promising as a radioactive device for clinical use.

  13. Rapid establishment of a regular distribution of adult tropical Drosophila parasitoids in a multi-patch environment by patch defence behaviour.

    Science.gov (United States)

    de Jong, Peter W; Hemerik, Lia; Gort, Gerrit; van Alphen, Jacques J M

    2011-01-01

    Females of the larval parasitoid of Drosophila, Asobara citri, from sub-Saharan Africa, defend patches with hosts by fighting and chasing conspecific females upon encounter. Females of the closely related, palearctic species Asobara tabida do not defend patches and often search simultaneously in the same patch. The effect of patch defence by A. citri females on their distribution in a multi-patch environment was investigated, and their distributions were compared with those of A. tabida. For both species 20 females were released from two release-points in replicate experiments. Females of A. citri quickly reached a regular distribution across 16 patches, with a small variance/mean ratio per patch. Conversely, A. tabida females initially showed a clumped distribution, and after gradual dispersion, a more Poisson-like distribution across patches resulted (variance/mean ratio was closer to 1 and higher than for A. citri). The dispersion of A. tabida was most probably an effect of exploitation: these parasitoids increasingly made shorter visits to already exploited patches. We briefly discuss hypotheses on the adaptive significance of patch defence behaviour or its absence in the light of differences in the natural history of both parasitoid species, notably the spatial distribution of their hosts.

  14. Robotic multi-well planar patch-clamp for native and primary mammalian cells

    Science.gov (United States)

    Milligan, Carol J; Li, Jing; Sukumar, Piruthivi; Majeed, Yasser; Dallas, Mark L; English, Anne; Emery, Paul; Porter, Karen E; Smith, Andrew M; McFadzean, Ian; Beccano-Kelly, Dayne; Bahnasi, Yahya; Cheong, Alex; Naylor, Jacqueline; Zeng, Fanning; Liu, Xing; Gamper, Nikita; Jiang, Lin-Hua; Pearson, Hugh A; Peers, Chris; Robertson, Brian; Beech, David J

    2009-01-01

    Multi-well robotic planar patch-clamp has become common in drug development and safety programmes because it enables efficient and systematic testing of compounds against ion channels during voltage-clamp. It has not, however, been adopted significantly in other important areas of ion channel research, where conventional patch-clamp remains the favoured method. Here we show the wider potential of the multi-well approach with the capability for efficient intracellular solution exchange, describing protocols and success rates for recording from a range of native and primary mammalian cells derived from blood vessels, arthritic joints, and the immune and central nervous systems. The protocol involves preparing a suspension of single cells to be dispensed robotically into 4-8 microfluidic chambers each containing a glass chip with a small aperture. Under automated control, giga-seals and whole-cell access are achieved followed by pre-programmed routines of voltage paradigms and fast extracellular or intracellular solution exchange. Recording from 48 chambers usually takes 1-6 hr depending on the experimental design and yields 16-33 cell recordings. PMID:19197268

  15. Intelligent Patching of Conceptual Geometry for CFD Analysis

    Science.gov (United States)

    Li, Wu

    2010-01-01

    The iPatch computer code for intelligently patching surface grids was developed to convert conceptual geometry to computational fluid dynamics (CFD) geometry (see figure). It automatically uses bicubic B-splines to extrapolate (if necessary) each surface in a conceptual geometry so that all the independently defined geometric components (such as wing and fuselage) can be intersected to form a watertight CFD geometry. The software also computes the intersection curves of surface patches at any resolution (up to 10.4 accuracy) specified by the user, and it writes the B-spline surface patches, and the corresponding boundary points, for the watertight CFD geometry in the format that can be directly used by the grid generation tool VGRID. iPatch requires that input geometry be in PLOT3D format where each component surface is defined by a rectangular grid {(x(i,j), y(i,j), z(i,j)):1less than or equal to i less than or equal to m, 1 less than or equal to j less than or equal to n} that represents a smooth B-spline surface. All surfaces in the PLOT3D file conceptually represent a watertight geometry of components of an aircraft on the half-space y greater than or equal to 0. Overlapping surfaces are not allowed, but could be fixed by a utility code "fixp3d". The fixp3d utility code first finds the two grid lines on the two surface grids that are closest to each other in Hausdorff distance (a metric to measure the discrepancies of two sets); then uses one of the grid lines as the transition line, extending grid lines on one grid to the other grid to form a merged grid. Any two connecting surfaces shall have a "visually" common boundary curve, or can be described by an intersection relationship defined in a geometry specification file. The intersection of two surfaces can be at a conceptual level. However, the intersection is directional (along either i or j index direction), and each intersecting grid line (or its spine extrapolation) on the first surface should intersect

  16. A Patch to MCNP5 for Multiplication Inference: Description and User Guide

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, Jr., Clell J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-05-05

    A patch to MCNP5 has been written to allow generation of multiple neutrons from a spontaneous-fission event and generate list-mode output. This report documents the implementation and usage of this patch.

  17. Measured Leak Rate of Ammonia Through an Epoxy/Stainless-Steel Patch

    National Research Council Canada - National Science Library

    Brady, B. B; Desain, J. D; Curtiss, T. J

    2007-01-01

    .... To assess the lifetime of the patch and sensitivity to manufacturing variation, simulated leaks in circular aluminum discs were patched with several different variants on the same epoxy-stainless materials system...

  18. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  19. Comprehensive field evaluation of asphalt patching methods and development of simple decision trees and a best practices manual.

    Science.gov (United States)

    2017-06-01

    The long-term performance of pothole patches largely depends on the selection of the patching method. A number of pothole patching methods are in practice in Minnesota and other nearby states. However, pavement maintenance crews often encounter probl...

  20. Piper betle LEAVES EXTRACT PATCH: EVALUATION OF ANTIBACTERIAL ACTIVITY, RELEASE PROFILE OF EUGENOL, AND LOCAL TOLERANCE

    Directory of Open Access Journals (Sweden)

    Mufrod Mufrod

    2016-08-01

    Full Text Available Piper betle leaf in extract form is more effective than crude drug. Eugenol is a component in the extract that has antibacterial activity but irritate. Patch of piper betle leaf extract was used on the mucosa to make oral cavity hygiene. Antibacterial activity was influenced by the release of eugenol from the patch. Release enhancer substances (RES such as glycerin, propylen glicol and tween 80 were added in patch formulation to increase the release of active substances. The aim of the research was to investigate the physicochemical properties, eugenol release profiles, and local tolerance test of the patch. Extract of piper betle leaf was made using infundation method. Patch was made according to the variation concentration of extract (1, 2 and 4% and RES (glycerine, propylen glycol and tween 80 using chitosan as vehicle. Patch produced solvent casting method. Patch obtained was tested for swelling index, folding endurance, surface pH, antibacterial activity, release of eugenol, and local tolerance. Data obtained were analyzed descriptively. The result showed that the addition of RES did not affect the surface pH but increase the water absorption with in inconsistent way except patch with tween 80. The flexibility (folding endurance value increased, and the highest amount of eugenol released was achieved by patch using propylen glicol. Patch with tween 80 and glycerin for all extract concentration and patch with 1% extract concentration using propylen glycol showed medium sensation (local tolerance, and patch with 2 and 4% extract using propylen glycol showed severe sensation.

  1. Efficacy of a single dose of a transdermal diclofenac patch as pre ...

    African Journals Online (AJOL)

    Background: We compared the analgesic efficacy of a transdermal diclofenac patch 100 mg (NuPatch® 100, Zydus Cadila, Ahmedabad, India) and intramuscular diclofenac sodium 75 mg (Voveran®, Novartis, India) for postoperative analgesia, and the associated side-effects of the transdermal diclofenac patch. Method: ...

  2. A New Low-Complexity Patch-based Super-Resolution

    DEFF Research Database (Denmark)

    Rasti, Pejman; Nasrollahi, Kamal; Orlova, Olga

    2017-01-01

    through an illumination enhancement process resulting in consistency of illumination between neigh- bour patches. This process is applied to all patches of the LR image. Finally, in order to remove the blocking effect caused by merging the patches, an average of the obtained HR image and the interpolated...

  3. A new low-complexity patch-based image super-resolution

    DEFF Research Database (Denmark)

    Rasti, Pejman; Nasrollahi, Kamal; Orlova, Olga

    2017-01-01

    through an illumination enhancement process resulting in consistency of illumination between neigh- bour patches. This process is applied to all patches of the LR image. Finally, in order to remove the blocking effect caused by merging the patches, an average of the obtained HR image and the interpolated...

  4. Histological distinction between early allergic and irritant patch test reactions

    DEFF Research Database (Denmark)

    Vestergaard, L; Clemmensen, Ole; Sørensen, Flemming Brandt

    1999-01-01

    no recognizable changes except a slight follicular spongiosis in 1 patient. The 2 pathologists agreed independently on the correct classification in 6 out of 7 cases (p=0.0156). We tested an optimized model, selecting non-irritant allergens and a well-known irritant. Further investigations are needed to elucidate......Comparative light microscopic studies have revealed subtle differences between allergic and irritant reactions in the skin. In the search for specific differences, we focussed on the early inflammatory response. This pilot study was conducted to test the hypothesis that follicular spongiosis can...... differentiate between early allergic and irritant patch test reactions. 8 patients with known contact allergy to either colophony or quarternium-15 participated in the study. In each patient, allergic and irritant patch tests reactions were elicited, and 4-mm punch biopsies were taken after 6 8 h from...

  5. Patch test dose-response study of p-phenylenediamine

    DEFF Research Database (Denmark)

    Sosted, Heidi; Menné, Torkil; Johansen, Jeanne Duus

    2006-01-01

    The elicitation response in allergic contact dermatitis for the hair dye substance p-phenylenediamine (PPD) is dose dependent, but threshold concentrations have not previously been investigated. 15 PPD-sensitive patients participated in a serial dilution 48-hr patch test with PPD using 8...... concentrations of PPD ranging from 1 to 10 000 on the upper back. Petrolatum was applied as control. Three concentrations (50, 100 and 500 p.p.m. PPD) were also applied to the retroauricular area and on the lateral aspects of the upper arms. 14 of the 15 participants reacted to one or more of the test samples....... The threshold value for 10% of the tested persons (ED10) based on+or stronger reactions for PPD on the back was 38 p.p.m. (CI: 4.3-100). There were no statistically significant differences in the sensitivity of the three anatomical regions. The upper back is a suitable region for patch testing patients...

  6. Vibration suppression of composite laminated beams using distributed piezoelectric patches

    International Nuclear Information System (INIS)

    Foda, M A; Almajed, A A; ElMadany, M M

    2010-01-01

    The focus of this paper is to develop an analytical and straightforward approach to suppress the steady state transverse vibration of a symmetric cross-ply laminated composite beam that is excited by an external harmonic force. This is achieved by bonding patches of piezoelectric material at selected locations along the beam. The governing equations for the system are formulated and the dynamic Green's functions are used to obtain an exact solution for the problem. A scheme is proposed for determining the values of the driving voltages, the dimensions of the PZT patches and their locations along the beam, in order to confine the vibration in a certain chosen region where the vibration is not harmful and leave the other chosen region stationary or vibrating with very small amplitudes. Beams with different boundary conditions are considered. Numerical case studies are presented to verify the utility of the proposed scheme

  7. Performance Enhancement of the Patch Antennas Applying Micromachining Technology

    Directory of Open Access Journals (Sweden)

    Mohamed N. Azermanesh

    2007-09-01

    Full Text Available This paper reports on the application of micromachining technology for performance enhancement of two types of compact antennas which are becoming a common practice in microsystems. Shorted patch antennas (SPA and folded shorted patch antennas operating in the 5-6 GHz ISM band, with intended application in short-range wireless communications, are considered. The electrical length of antennas are modified by etching the substrate of the antennas, thus providing a new degree of freedom to control the antenna operating properties, which is the main novelty of our work. The gain and bandwidth of the antennas are increased by increasing the etching depth. However, etching the substrate affects the operating frequency as well. To keep the operating frequency at a pre-specified value, the dimension of the antennas must be increased by deepening the etching depth. Therefore, a trade off between the performance enhancement of the antennas and the dimensional enlargement is required.

  8. Comparison of shrinkage related properties of various patch repair materials

    Science.gov (United States)

    Kristiawan, S. A.; Fitrianto, R. S.

    2017-02-01

    A patch repair material has been developed in the form of unsaturated polyester resin (UPR)-mortar. The performance and durability of this material are governed by its compatibility with the concrete being repaired. One of the compatibility issue that should be tackled is the dimensional compatibility as a result of differential shrinkage between the repair material and the concrete substrate. This research aims to evaluate such shrinkage related properties of UPR-mortar and to compare with those of other patch repair materials. The investigation includes the following aspects: free shrinkage, resistance to delamination and cracking. The results indicate that UPR-mortar poses a lower free shrinkage, lower risk of both delamination and cracking tendency in comparison to other repair materials.

  9. Analysis of Microstrip Line Fed Patch Antenna for Wireless Communications

    Directory of Open Access Journals (Sweden)

    Singh Ashish

    2017-11-01

    Full Text Available In this paper, theoretical analysis of microstrip line fed rectangular patch antenna loaded with parasitic element and split-ring resonator is presented. The proposed antenna shows that the dualband operation depends on gap between parasitic element, split-ring resonator, length and width of microstrip line. It is found that antenna resonates at two distinct resonating modes i.e., 0.9 GHz and 1.8 GHz for lower and upper resonance frequencies respectively. The antenna shows dual frequency nature with frequency ratio 2.0. The characteristics of microstrip line fed rectangular patch antenna loaded with parasitic element and split-ring resonator antenna is compared with other prototype microstrip line fed antennas. Further, the theoretical results are compared with simulated and reported experimental results, they are in close agreement.

  10. Software approach to automatic patching of analog computer

    Science.gov (United States)

    1973-01-01

    The Automatic Patching Verification program (APV) is described which provides the hybrid computer programmer with a convenient method of performing a static check of the analog portion of his study. The static check insures that the program is patched as specified, and that the computing components being used are operating correctly. The APV language the programmer uses to specify his conditions and interconnections is similar to the FORTRAN language in syntax. The APV control program reads APV source program statements from an assigned input device. Each source program statement is processed immediately after it is read. A statement may select an analog console, set an analog mode, set a potentiometer or DAC, or read from the analog console and perform a test. Statements are read and processed sequentially. If an error condition is detected, an output occurs on an assigned output device. When an end statement is read, the test is terminated.

  11. Epidural blood patch for refractory low CSF pressure headache

    DEFF Research Database (Denmark)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication...... of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our......Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists...

  12. Epidural blood patch for refractory low CSF pressure headache

    DEFF Research Database (Denmark)

    Madsen, Søren Aalbæk; Fomsgaard, Jonna Storm; Jensen, Rigmor

    2011-01-01

    of non-invasive/conservative measures and invasive measures with epidural blood patch providing the cornerstone of the invasive measures. In the present pilot study we therefore aimed to evaluate the treatment efficacy of epidural blood patch (EBP) in treatment-refractory low-pressure headache. Our......Once believed an exceedingly rare disorder, recent evidence suggests that low cerebrospinal fluid (CSF) pressure headache has to be considered an important cause of new daily persistent headaches, particularly among young and middle-aged individuals. Treatment of low CSF pressure headache consists...... primary effect parameter was total headache burden defined as area under the curve (AUC: intensity × duration) and as secondary effect parameters we identified: intensity (VAS 0-10), frequency (days per month), duration in hours (total hours/month) and also medication days (days on medication...

  13. Effect of ionizing radiation on apoptosis in mouse Peyer's patches

    International Nuclear Information System (INIS)

    Liu Jiamei; Chen Dong; Liu Shuzheng

    1999-01-01

    The relationship of time-effect and dose-effect of apoptosis in mouse Peyer's patches after whole body irradiation (WBI) with different doses of X-rays was studied by the method of TdT-mediated dUTP nick end labelling (TUNEL). The results showed that the number of TUNEL positive cells in mouse Peyer's patches were significantly increased following WBI with 2 Gy irradiation, While the number of TUNEL positive cells were decreased after WBI with doses of 0.05 Gy and 0.075 Gy X-rays. the results support the view that 2 Gy irradiation promote the apoptosis of immune cells and the low doses of radiation suppress the apoptosis of immune cells

  14. Gigaseal formation in patch clamping with applications of nanotechnology

    CERN Document Server

    Malboubi, Majid

    2014-01-01

    This book presents an investigation of gigaseal formation using micro/nanotechnology. The aims of the book are twofold. First, it explains the mechanisms of gigaseal formation using the latest discoveries. Second, it provides practical techniques for frequent formation of high resistance seals. The formation of a high-resistance electrical seal, also known as a gigaseal, between a cell membrane and a glass micropipette tip is essential in patch-clamp experiments. Even though four decades have passed since the introduction of the patch-clamping technique by Neher and Sakmann, gigaseal formation remains an obstacle in developing the high-throughput ion channel screening systems required by the pharmaceutical industry. Here the authors share their latest methods for achieving gigaseal formation and describe techniques that are highly desirable at both research and industrial levels. Nanotechnology has been found to be a powerful tool for studying and modifying glass micropipettes and in tackling the problem of g...

  15. A patch in the pectoral position lowers defibrillation threshold.

    Science.gov (United States)

    Karasik, P; Solomon, A; Verdino, R; Moore, H; Rodak, D; Hannan, R; Fletcher, R

    1997-06-01

    Implantable pacemaker cardioverter defibrillators are now available with biphasic waveforms, which have been shown to markedly improve defibrillation thresholds (DFTs). However, in a number of patients the DFT remains high. Also, DFT may increase after implantation, especially if antiarrhythmic drugs are added. We report on the use of a subcutaneous patch in the pectoral position in 15 patients receiving a transvenous defibrillator as a method of easily reducing the DFT. A 660-mm2 patch electrode was placed beneath the generator in a pocket created on the pectoral fascia. The energy required for defibrillation was lowered by 56% on average, and the system impedance was lowered by a mean of 25%. This maneuver allowed all patients to undergo a successful implant with adequate safety margin.

  16. Evaluation and comparison of dimensional accuracy of newly introduced elastomeric impression material using 3D laser scanners: an in vitro study.

    Science.gov (United States)

    Pandita, Amrita; Jain, Teerthesh; Yadav, Naveen S; Feroz, S M A; Pradeep; Diwedi, Akankasha

    2013-03-01

    Aim of the present study was to comparatively evaluate dimensional accuracy of newely introduced elastomeric impression material after repeated pours at different time intervals. In the present study a total of 20 (10 + 10) impressions of master model were made from vinyl polyether silicone and vinyl polysiloxane impression material. Each impression was repeatedly poured at 1, 24 hours and 14 days. Therefore, a total of 60 casts were obtained. Casts obtained were scanned with three-dimensional (3D) laser scanner and measurements were done. Vinyl polyether silicone produced overall undersized dies, with greatest change being 0.14% only after 14 days. Vinyl polysiloxane produced smaller dies after 1 and 24 hours and larger dies after 14 days, differing from master model by only 0.07% for the smallest die and to 0.02% for the largest die. All the deviations measured from the master model with both the impression materials were within a clinically acceptable range. In a typical fixed prosthodontic treatment accuracy of prosthesis is critical as it determines the success, failure and the prognosis of treatment including abutments. This is mainly dependent upon fit of prosthesis which in turn is dependent on dimensional accuracy of dies, poured from elastomeric impressions.

  17. Novel elastomeric fibrous networks produced from poly(xylitol sebacate)2:5 by core/shell electrospinning: fabrication and mechanical properties.

    Science.gov (United States)

    Li, Yuan; Thouas, George A; Chen, Qizhi

    2014-12-01

    Fabrication of nonlinear elastic materials that resemble biological tissues remains a challenge in biomaterials research. Here, a new fabrication protocol to produce elastomeric fibrous scaffolds was established, using the core/shell electrospinning technique. A prepolymer of poly(xylitol sebacate) with a 2:5mol ratio of xylitol:sebacic acid (PXS2:5) was first formulated, then co-electrospun with polyvinyl alcohol (PVA - 95,000Mw). After cross-linking of core polymer PXS2:5, the PVA shells were rinsed off in water, leaving a porous elastomeric network of PXS2:5 fibres. Under aqueous conditions, the PXS2:5 fibrous scaffolds exhibited stable, nonlinear J-shaped stress-strain curves, with large average rupture elongation (76%) and Young׳s modulus (~1.0MPa), which were in the range of muscle tissue. Rupture elongation of PXS2:5 was also much higher when electrospun, compared to 2D solid sheets (45%). In direct contact with cell monolayers under physiological conditions, PXS2:5 scaffolds were as biocompatible as those made of poly-l-lactic acid (PLLA), with improvements over culture medium alone. In conclusion, the newly developed porous PXS2:5 scaffolds show tissue-like mechanical properties and excellent biocompatibility, making them very promising for bioengineering of soft tissues and organs. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Rumen metabolism and absorption of a 14C-labelled elastomeric copolymer and its value as a roughage substitute for cattle

    International Nuclear Information System (INIS)

    Bartley, E.E.; Meyer, R.M.; Call, E.P.

    1981-01-01

    Several synthetic elastomeric and plastomeric polymers were tested for suitability as artificial roughages. They were fed to rumenfistulated cattle fed grain only. Several of the polymers were regurgitated, remasticated and reswallowed, and they formed thin strands of intermeshed fiber that produced a large, loosely woven hay-like mass that floated on the rumen contents. An elastomeric polymer consisting of copolymers of 80 to 90% ethylene and 10 to 20% propylene, with a tensile strength at yield of 45.7 kg/cm2, a hardness of 30 units (Shore D hardness scale) and a tensile strength at 300% elongation of 51.0 kg/cm2, was selected for further testing. The copolymer was fed at about 90 g/head daily for 127 days to cattle fed grain only. At slaughter, rumens contained an average of 8.0 kg copolymer (dry basis). Cattle fed the copolymer had healthier rumen papillae and epithelia of the abomasum and small intestines than did control animals fed grain only. Using 14 C-labeled copolymer, we found that the copolymer was not degraded by rumen microorganisms or acid-pepsin solution. When 14 C-labeled copolymer was fed to milking cows, no 14 C activity was found in milk, blood or urine. Upon slaughter, about 100% of the 14 C activity was recovered from digesta and feces. We concluded that the copolymer was not absorbed from the digestive tract

  19. Finite element analysis of actively controlled smart plate with patched actuators and sensors

    Directory of Open Access Journals (Sweden)

    M. Yaqoob Yasin

    Full Text Available The active vibration control of smart plate equipped with patched piezoelectric sensors and actuators is presented in this study. An equivalent single layer third order shear deformation theory is employed to model the kinematics of the plate and to obtain the shear strains. The governing equations of motion are derived using extended Hamilton's principle. Linear variation of electric potential across the piezoelectric layers in thickness direction is considered. The electrical variable is discretized by Lagrange interpolation function considering two-noded line element. Undamped natural frequencies and the corresponding mode shapes are obtained by solving the eigen value problem with and without electromechanical coupling. The finite element model in nodal variables are transformed into modal model and then recast into state space. The dynamic model is reduced for further analysis using Hankel norm for designing the controller. The optimal control technique is used to control the vibration of the plate.

  20. How to Patch Active Plasma and Collisionless Sheath: Practical Guide

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.

    2002-01-01

    Most plasmas have a very thin sheath compared with the plasma dimension. This necessitates separate calculations of the plasma and sheath. The Bohm criterion provides the boundary condition for calculation of plasma profiles. To calculate sheath properties, a value of electric field at the plasma-sheath interface has to be specified in addition to the Bohm criterion. The value of the boundary electric field and robust procedure to approximately patch plasma and collisionless sheath with a very good accuracy are reported

  1. Patch-up system on GEC 4080 computer

    International Nuclear Information System (INIS)

    Bryden, A.D.

    1978-02-01

    The patch-up system for the rescue of events on bubble chamber film was described in Rutherford Laboratory Report RHEL-R-190 (1970). The present report highlights the changes that have had to be made to the system in the transfer from IBM 360/195 to the GEC 4080 computer and should be used in conjuction with the earlier report. (U.K.)

  2. Lateral spread affects nitrogen leaching from urine patches.

    Science.gov (United States)

    Cichota, Rogerio; Vogeler, Iris; Snow, Val; Shepherd, Mark; McAuliffe, Russell; Welten, Brendon

    2018-09-01

    Nitrate leaching from urine deposited by grazing animals is a critical constraint for sustainable dairy farming in New Zealand. While considerable progress has been made to understand the fate of nitrogen (N) under urine patches, little consideration has been given to the spread of urinary N beyond the wetted area. In this study, we modelled the lateral spread of nitrogen from the wetted area of a urine patch to the soil outside the patch using a combination of two process-based models (HYDRUS and APSIM). The simulations provided insights on the extent and temporal pattern for the redistribution of N in the soil following a urine deposition and enabled investigating the effect of lateral spread of urinary N on plant growth and N leaching. The APSIM simulation, using an implementation of a dispersion-diffusion function, was tested against experimental data from a field experiment conducted in spring on a well-drained soil. Depending on the geometry considered for the dispersion-diffusion function (plate or cylindrical) the area-averaged N leaching decreased by 8 and 37% compared with simulations without lateral N spread; this was due to additional N uptake from pasture on the edge area. A sensitivity analysis showed that area-averaged pasture growth was not greatly affected by the value of the dispersion factor used in the model, whereas N leaching was very sensitive. Thus, the need to account for the edge effect may depend on the objective of the simulations. The modelling results also showed that considering lateral spread of urinary N was sufficient to describe the experimental data, but plant root uptake across urine patch zones may still be relevant in other conditions. Although further work is needed for improving accuracy, the simulated and experimental results demonstrate that accounting for the edge effect is important for determining N leaching from urine-affected areas. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. An Efficient Patch Dissemination Strategy for Mobile Networks

    OpenAIRE

    Zhao, Dawei; Peng, Haipeng; Li, Lixiang; Yang, Yixian; Li, Shudong

    2013-01-01

    Mobile phones and personal digital assistants are becoming increasingly important in our daily life since they enable us to access a large variety of ubiquitous services. Mobile networks, formed by the connection of mobile devices following some relationships among mobile users, provide good platforms for mobile virus spread. Quick and efficient security patch dissemination strategy is necessary for the update of antivirus software so that it can detect mobile virus, especially the new vir...

  4. Patch test with ether extracts in salicaceae allergy

    Directory of Open Access Journals (Sweden)

    Sawhney M

    2002-01-01

    Full Text Available A total of 23 cases suggestive of airborne contact dermatitis were patch tested with ether extracts of flowers and leaves of populus sp. and salix sp. in a study conducted in Ladakh at an altitude of 3445 meters above sea level. Overall positivity was found in 12 (52.17%, with populus sp. alone in 7 (30. 43%, salix sp. alone in 4 17.39% and to both in one (8.33%.

  5. Reconfigurable Patch Antenna Radiations Using Plasma Faraday Shield Effect

    OpenAIRE

    Barro , Oumar Alassane; Himdi , Mohamed; Lafond , Olivier

    2016-01-01

    International audience; This letter presents a new reconfigurable antenna associated with a plasma Faraday shield effect. The Faraday shield effect is realized by using a fluorescent lamp. A patch antenna operating at 2.45 GHz is placed inside the lamp. The performance of the reconfigurable system is observed in terms of S11, gain and radiation patterns by simulation and measurement. It is shown that by switching ON the fluorescent lamp, the gain of the antenna decreases and the antenna syste...

  6. Diclofenac epolamine topical patch relieves pain associated with ankle sprain

    Directory of Open Access Journals (Sweden)

    David R Lionberger

    2011-03-01

    Full Text Available David R Lionberger1, Eric Joussellin2, Arturo Lanzarotti3, Jillmarie Yanchick4, Merrell Magelli5 1Southwest Orthopedic Group, LLP, Houston, Texas, USA; 2Institut National du Sport, Paris, France; 3Institut Biochimique SA, Pambionoranco, Switzerland; 4Alpharma Pharmaceuticals LLC, a wholly owned subsidiary of King Pharmaceuticals®, Inc, Piscataway, New Jersey, USA; 5GTx, Inc, Memphis, Tennessee, USABackground: Sports-related injuries, such as sprains and strains, commonly occur during exercise and athletic events. Current therapy includes nonsteroidal anti-inflammatory drugs (NSAIDs, which have a high incidence of upper gastrointestinal side effects. The present study assessed the efficacy and safety of the diclofenac epolamine topical patch (DETP, 1.3%, a topical NSAID for the treatment of acute minor sprains and strains.Methods: This multicenter, randomized, placebo-controlled clinical study enrolled adult patients (n = 134 with acute ankle pain (due to a minor sprain occurring less than 48 hours prior to entering the study. Patients were treated with either the DETP or a placebo topical patch daily for seven days. Pain intensity was evaluated during the first six hours after application of the patch, and on treatment days 1, 2, 3, and 7.Results: Patients treated with the DETP experienced a significantly greater reduction in pain associated with their ankle injury compared with placebo, beginning four hours after the first patch application (P = 0.02. The DETP was well tolerated and was comparable with placebo in terms of safety.Conclusion: Overall, the results of this study demonstrate that the DETP is an effective analgesic for local treatment of pain in mild acute ankle sprain.Keywords: soft tissue injury, acute pain, visual analog scale, efficacy, tolerability 

  7. Sutureless human sclera donor patch graft for Ahmed glaucoma valve.

    Science.gov (United States)

    Zeppa, Lucio; Romano, Mario R; Capasso, Luigi; Tortori, Achille; Majorana, Mara A; Costagliola, Ciro

    2010-01-01

    To report the safety and effectiveness of a sutureless human sclera donor patch graft covering the subconjunctival portion of glaucoma drainage implant tube to prevent its erosion throughout the overlying conjunctiva. This was a prospective pilot study. Fifteen eyes of 15 consecutive patients not responsive to medical and to not-implant surgical glaucoma treatment underwent Ahmed glaucoma valve (AGV) implant surgery with sutureless human sclera donor patch graft. The surgical procedure included AVG implant placed 8 mm behind the corneal limbus and fixed to the sclera with two 9-0 black nylon sutures. The tube was passed through the scleral tunnel, parallel to the corneal limbus, and shortened at the desired length. The anterior part of the tube was covered with human donor scleral graft and kept in place with fibrin glue (Tissue Coll) under the conjunctiva. Examinations were scheduled at baseline and then at 1 week and 1, 3, 6, and 12 months after surgery. At 12-month follow-up, the best-corrected visual acuity did not significantly improve from baseline 0.78+/-1.2 logMAR, whereas mean intraocular pressure significantly decreased from preoperative values of 29.8 (SD 8.4) mmHg. In all cases, the scleral patch was found in place at each check during the follow-up period. No conjunctival erosion over the AGV tube nor sign of endophthalmitis was recorded at any time during the follow-up period. AVG implant surgery with sutureless human sclera donor patch graft represents an effective and relatively safe surgical procedure for complicated glaucomas, avoiding conjunctival erosions over the AGV tube.

  8. Experimental and computational laser tissue welding using a protein patch.

    Science.gov (United States)

    Small, W; Heredia, N J; Maitland, D J; Eder, D C; Celliers, P M; Da Silva, L B; London, R A; Matthews, D L

    1998-01-01

    An in vitro study of laser tissue welding mediated with a dye-enhanced protein patch was conducted. Fresh sections of porcine aorta were used for the experiments. Arteriotomies were treated using an indocyanine green dye-enhanced collagen patch activated by an 805-nm continuous-wave fiber-delivered diode laser. Temperature histories of the surface of the weld site were obtained using a hollow glass optical fiber-based two-color infrared thermometer. The experimental effort was complemented by simulations with the LATIS (LAser-TISsue) computer code, which uses coupled Monte Carlo, thermal transport, and mass transport models. Comparison of simulated and experimental thermal data indicated that evaporative cooling clamped the surface temperature of the weld site below 100 °C. For fluences of approximately 200 J/cm2, peak surface temperatures averaged 74°C and acute burst strengths consistently exceeded 0.14×106 dyn/cm (hoop tension). The combination of experimental and simulation results showed that the inclusion of water transport and evaporative losses in the computer code has a significant impact on the thermal distributions and hydration levels throughout the tissue volume. The solid-matrix protein patch provided a means of controllable energy delivery and yielded consistently strong welds. © 1998 Society of Photo-Optical Instrumentation Engineers.

  9. Patch-based visual tracking with online representative sample selection

    Science.gov (United States)

    Ou, Weihua; Yuan, Di; Li, Donghao; Liu, Bin; Xia, Daoxun; Zeng, Wu

    2017-05-01

    Occlusion is one of the most challenging problems in visual object tracking. Recently, a lot of discriminative methods have been proposed to deal with this problem. For the discriminative methods, it is difficult to select the representative samples for the target template updating. In general, the holistic bounding boxes that contain tracked results are selected as the positive samples. However, when the objects are occluded, this simple strategy easily introduces the noises into the training data set and the target template and then leads the tracker to drift away from the target seriously. To address this problem, we propose a robust patch-based visual tracker with online representative sample selection. Different from previous works, we divide the object and the candidates into several patches uniformly and propose a score function to calculate the score of each patch independently. Then, the average score is adopted to determine the optimal candidate. Finally, we utilize the non-negative least square method to find the representative samples, which are used to update the target template. The experimental results on the object tracking benchmark 2013 and on the 13 challenging sequences show that the proposed method is robust to the occlusion and achieves promising results.

  10. Formulation of Bilayer Benzydamine HCl Patch Targeted For Gingivitis

    Directory of Open Access Journals (Sweden)

    Piyush Sanghai

    2016-01-01

    Full Text Available In the present study bilayer patch of benzydamine HCl was developed using solvent casting method. Different substrates were attempted like Petri dish, glass-and-ring, and teflon-and-ring for selection of the proper option to formulate patch that should give easily peelable film with adequate mechanical properties. HPMC E15 LV was used in different concentrations for obtaining proper viscosity of solution for pouring on to surface and ring, that it should not leak from ring. The second layer was optimized by using different polymer like eudragit RSPO, eudragit RSPO + EC, and eudragit NE30 D for efficient layer bonding. The minimum release from backing membrane was established by diffusion study as compared to from drug loaded layer. The optimized batches were evaluated for folding endurance, weight variation, thickness, drug content, drug release, tensile strength, layer separation, mucoadhesion, moisture uptake, and layer bonding. The novel gingival patch of benzydamine HCl developed would be beneficial in optimizing the therapy.

  11. Self-Replication of Localized Vegetation Patches in Scarce Environments

    Science.gov (United States)

    Bordeu, Ignacio; Clerc, Marcel G.; Couteron, Piere; Lefever, René; Tlidi, Mustapha

    2016-09-01

    Desertification due to climate change and increasing drought periods is a worldwide problem for both ecology and economy. Our ability to understand how vegetation manages to survive and propagate through arid and semiarid ecosystems may be useful in the development of future strategies to prevent desertification, preserve flora—and fauna within—or even make use of scarce resources soils. In this paper, we study a robust phenomena observed in semi-arid ecosystems, by which localized vegetation patches split in a process called self-replication. Localized patches of vegetation are visible in nature at various spatial scales. Even though they have been described in literature, their growth mechanisms remain largely unexplored. Here, we develop an innovative statistical analysis based on real field observations to show that patches may exhibit deformation and splitting. This growth mechanism is opposite to the desertification since it allows to repopulate territories devoid of vegetation. We investigate these aspects by characterizing quantitatively, with a simple mathematical model, a new class of instabilities that lead to the self-replication phenomenon observed.

  12. Parametric study on patch repaired CFRP laminates using FEA

    Energy Technology Data Exchange (ETDEWEB)

    Kashfuddoja, M.; Ramji, M. [Indian Institute of Technology. Engineering Optics Lab. Dept. of Mechanical Engineering, Hyderabad (India)

    2012-07-01

    Carbon fibre reinforced plastic (CFRP) composite laminates have become popular for structural applications as they are lighter, stronger and tougher. Composite structures are also susceptible to damage while in service. For improved service life, the damage needs to be repaired so that repair structure integrity is enhanced. Various parameters like patch size and shape, it's layup sequence and adhesive thickness would influence the performance of the repaired structure. In present work, a parametric study is carried out using finite element analysis (FEA) to investigate the influence of various parameters involved in composite repair. The panel is made of carbon / epoxy composite laminate with stacking sequence of (0/{+-}45/900)s and is subjected to tensile load. Damaged CFRP laminates is repaired by symmetrical patch adhesively bonded over the damaged area. Circular patch of different stacking sequence and size is considered. Influence of adhesive material and it's thickness on repair efficiency is also investigated. The influence of various repair parameters on peel stress is also analysed. (Author)

  13. Bandwidth-Enhanced Low-Profile Antenna with Parasitic Patches

    Directory of Open Access Journals (Sweden)

    Son Xuat Ta

    2017-01-01

    Full Text Available This paper presents low-profile broadband antennas, which are composed of four parasitic patches placed between planar radiators and a perfect electric conductor ground plane. Two types of planar radiators, a conventional dipole and a crossed dipole, are employed to produce linearly polarized (LP and circularly polarized (CP radiations, respectively. The radiator and parasitic patches are realized on thin substrates to lower the cost. Owing to the presence of parasitic patches, the antenna performance improves in terms of profile reduction, resonant frequency decrease, and bandwidth enhancement. These improvements are discussed and confirmed computationally and experimentally. The LP design with the overall dimensions of 120 mm × 120 mm × 16.3 mm (0.64λ0 × 0.64λ0 × 0.087λ0 at 1.6 GHz has a |S11|  96%. The CP design, which has the same physical size as the LP case, has a |S11|  90%.

  14. Exploring Potential Foreshocks on Highly Compressed Patches in a Rate-and-State Fault Model

    Science.gov (United States)

    Higgins, N.; Lapusta, N.

    2015-12-01

    On both natural and laboratory faults, some mainshocks are preceded by foreshocks. Such foreshocks may be triggered by aseismic processes of the mainshock nucleation at fault heterogeneities such as bumps, as inferred in some laboratory experiments. We explore a rate-and-state fault model in which potential foreshocks occur on patches of elevated normal compression (by a factor of 5 to 10) within a larger velocity-weakening (VW) region, using 3D numerical simulations of long-term earthquake sequences and aseismic slip. We find that this model produces isolated microseismicity during the nucleation of a larger-scale seismic event, under the following conditions: (i) Patch diameter D is comparable to or larger than the patch nucleation size h*patch; (ii) D is much smaller than the nucleation size h*main for the larger-scale VW region; otherwise, a patch-hosted event simply starts the larger-scale event; (iii) the patches are sufficiently separated to prevent them triggering each other nearly instantaneously. Hence the nucleation sizes h*main and h*patch need to be substantially different, by a factor of around 10 in our simulations so far, and potentially much more. The aforementioned separation of scales can be achieved by assigning high levels of compression on the patches. However, one would expect unrealistically large stress drops for events on such patches. Remarkably, in this model, we find that the stress drops of the patch-hosted events are reasonable and roughly constant, despite a wide variation in the patch compression, due to patch ruptures extending into the surrounding VW region. Furthermore, for D close to h*patch, a substantial part of the stress change on the patch occurs aseismically. Our current work is directed towards quantifying and explaining these trends, as well as exploring whether the microseismicity occurring on highly compressed patches due to nucleation-induced creep has any observable differences from other events.

  15. Spatially adapted augmentation of age-specific atlas-based segmentation using patch-based priors

    Science.gov (United States)

    Liu, Mengyuan; Seshamani, Sharmishtaa; Harrylock, Lisa; Kitsch, Averi; Miller, Steven; Chau, Van; Poskitt, Kenneth; Rousseau, Francois; Studholme, Colin

    2014-03-01

    One of the most common approaches to MRI brain tissue segmentation is to employ an atlas prior to initialize an Expectation- Maximization (EM) image labeling scheme using a statistical model of MRI intensities. This prior is commonly derived from a set of manually segmented training data from the population of interest. However, in cases where subject anatomy varies significantly from the prior anatomical average model (for example in the case where extreme developmental abnormalities or brain injuries occur), the prior tissue map does not provide adequate information about the observed MRI intensities to ensure the EM algorithm converges to an anatomically accurate labeling of the MRI. In this paper, we present a novel approach for automatic segmentation of such cases. This approach augments the atlas-based EM segmentation by exploring methods to build a hybrid tissue segmentation scheme that seeks to learn where an atlas prior fails (due to inadequate representation of anatomical variation in the statistical atlas) and utilize an alternative prior derived from a patch driven search of the atlas data. We describe a framework for incorporating this patch-based augmentation of EM (PBAEM) into a 4D age-specific atlas-based segmentation of developing brain anatomy. The proposed approach was evaluated on a set of MRI brain scans of premature neonates with ages ranging from 27.29 to 46.43 gestational weeks (GWs). Results indicated superior performance compared to the conventional atlas-based segmentation method, providing improved segmentation accuracy for gray matter, white matter, ventricles and sulcal CSF regions.

  16. Regions of mid-level human visual cortex sensitive to the global coherence of local image patches.

    Science.gov (United States)

    Mannion, Damien J; Kersten, Daniel J; Olman, Cheryl A

    2014-08-01

    The global structural arrangement and spatial layout of the visual environment must be derived from the integration of local signals represented in the lower tiers of the visual system. This interaction between the spatially local and global properties of visual stimulation underlies many of our visual capacities, and how this is achieved in the brain is a central question for visual and cognitive neuroscience. Here, we examine the sensitivity of regions of the posterior human brain to the global coordination of spatially displaced naturalistic image patches. We presented observers with image patches in two circular apertures to the left and right of central fixation, with the patches drawn from either the same (coherent condition) or different (noncoherent condition) extended image. Using fMRI at 7T (n = 5), we find that global coherence affected signal amplitude in regions of dorsal mid-level cortex. Furthermore, we find that extensive regions of mid-level visual cortex contained information in their local activity pattern that could discriminate coherent and noncoherent stimuli. These findings indicate that the global coordination of local naturalistic image information has important consequences for the processing in human mid-level visual cortex.

  17. Effect of novel mucoadhesive buccal patches of carvedilol on isoprenaline-induced tachycardia

    Directory of Open Access Journals (Sweden)

    Navneet Verma

    2014-01-01

    Full Text Available The main aim of the study was designed to develop bioadhesive buccal patches of carvedilol (CR and evaluate for isoprenaline-induced tachycardia. Buccal patches of carvedilol were prepared by using chitosan (CH, sodium salt of carboxy methyl cellulose (NaCMC, and polyvinyl alcohol (PVA as mucoadhesive polymers. The solvent evaporation method was used for the preparation of buccal patches. The patches were evaluated for their physical characteristics like patch thickness, weight variation, content uniformity, folding endurance, surface pH, residence time, in vitro drug release, and in vivo pharmacodynamic study. The swelling index of the patches was found to be proportional to the polymer concentration, whereas surface pH of all the formulated bioadhesive patches was found to lie between neutral ranges. In-vitro release study shows that 94.75% drug was release in 8 hours from the patch, which containing 2% w/v chitosan. The folding endurance result shows good elasticity in all the patches.Application of buccal patches on buccal mucosa of rabbit shows a significant result in % inhibition of isoprenaline-induced tachycardia. Prepared buccal patches of chitosan, NaCMC, and PVA containing Carvedilol meet the ideal requirement for the delivery of cardiovascular drugs and inhibit the isoprenaline tachycardia.

  18. Study on the electrostatic and piezoelectric properties of positive polypropylene electret cyclosporine A patch

    International Nuclear Information System (INIS)

    Guo, X; Liang, Y Y; Jiang, J; Liu, H Y; Cui, L L

    2013-01-01

    Corona charged electrets at voltages of +500 V, +1000 V and +1500 V were prepared for manufacturing polypropylene (PP) electret blank patches and PP electret drug patches. The stability of external electrostatic field of the electret patch and the polarization of the drug in patch under the internal electrostatic field of the electret were studied. The results indicate that all the electret drug patches had good charge storage stabilities. However, the non-electrode coated electret drug patch had better stability in the external electrostatic field than that of the electrode coated electret drug patch. The higher the charging voltage of the electret, the faster the surface potential of the electret drug patch decayed, and the worse the stability of the external electrostatic field. All the electrets used in this study could result in the polarization of the model drug in patch. The piezoelectric properties of non-electrode coated electret drug patch increased with the charging voltage of the electret. However, excessively higher charging voltage could result in the decreased polarization of the drug in patch. Both the stability of the external electrostatic field of electret and the polarization of drug were the key factors for controlled drug release and skin permeation.

  19. Effect of weed patch size on seed removal by harvester ants

    Directory of Open Access Journals (Sweden)

    Westermann, Paula R.

    2014-02-01

    Full Text Available In dryland cereals in North-eastern Spain, the harvester ant, Messor barbarus L., is responsible for removal of a large proportion of the newly produced weed seeds (40-100%. The probability that seeds will be found by the ants may be influenced by weed patch size. To investigate this source of variability, 30 seed patches were created in each of three, 50 × 50 m, blocks in a cereal field after harvest, by sequentially seeding (10, 16 and 17 August 2010 with 2000 seeds m-2 of Avena sativa L.. Patch size varied from 0.25 to 9 m2. Twenty four hours after seeding, the remaining seeds were collected and seed removal rates estimated. Average seed removal rate was lowest in the smallest (78-94% and highest in the largest patches (99-100%. Differences were mainly caused by the fact that some of the smaller patches (9.7% were not found. However, when patches were found, they were exploited at equal rates (98-100%. As predicted, the probability of finding a patch increased slightly, but significantly, with increasing patch size. When a patch was found, it was almost always fully exploited, resulting in very high seed removal rates, irrespective of patch size. These results indicate that the size of the seed patch is only a minor source of variation influencing this form of biological control of weeds.

  20. Departure mechanisms for host search on high-density patches by the Meteorus pulchricornis.

    Science.gov (United States)

    Sheng, Sheng; Feng, Sufang; Meng, Ling; Li, Baoping

    2014-01-01

    Less attention has been paid to the parasitoid-host system in which the host occurs in considerably high density with a hierarchical patch structure in studies on time allocation strategies of parasitoids. This study used the parasitoid Meteorus pulchricornis (Wesmael) (Hymenoptera: Braconidae) and the Oriental leafworm, Spodoptera litura (Fabricius) (Lepidoptera: Noctuidae) as the parasitoids-host model system to investigate patch-leaving mechanisms as affected by the high-host density, hierarchical patch structure, and foraging behaviors on both former and current patches. The results showed that three out of eight covariates tested had significant effects on the patch-leaving tendency, including the host density, ovipositor insertion, and host rejection on the current patch. The parasitoid paid more visits to the patch with high-density hosts. While the patch with higher host densities decreased the leaving tendency, the spatial distribution of hosts examined had no effect on the leaving tendency. Both oviposition and host rejection decreased the patch-leaving tendency. The variables associated with the former patch, such as the host density and number of ovipositor insertions, however, did not have an effect on the leaving tendency. Our study suggested that M. pulchricornis females may use an incremental mechanism to exploit high-density patches to the fullest. © The Author 2014. Published by Oxford University Press on behalf of the Entomological Society of America.

  1. The Development of M Cells in Peyer’s Patches Is Restricted to Specialized Dome-Associated Crypts

    Science.gov (United States)

    Gebert, Andreas; Fassbender, Susanne; Werner, Kerstin; Weissferdt, Annikka

    1999-01-01

    It is controversial whether the membranous (M) cells of the Peyer’s patches represent a separate cell line or develop from enterocytes under the influence of lymphocytes on the domes. To answer this question, the crypts that produce the dome epithelial cells were studied and the distribution of M cells over the domes was determined in mice. The Ulex europaeus agglutinin was used to detect M cells in mouse Peyer’s patches. Confocal microscopy with lectin-gold labeling on ultrathin sections, scanning electron microscopy, and laminin immuno-histochemistry were combined to characterize the cellular composition and the structure of the dome-associated crypts and the dome epithelium. In addition, the sites of lymphocyte invasion into the dome epithelium were studied after removal of the epithelium using scanning electron microscopy. The domes of Peyer’s patches were supplied with epithelial cells that derived from two types of crypt: specialized dome-associated crypts and ordinary crypts differing not only in shape, size, and cellular composition but also in the presence of M cell precursors. When epithelial cells derived from ordinary crypts entered the domes, they formed converging radial strips devoid of M cells. In contrast to the M cells, the sites where lymphocytes invaded the dome epithelium were not arranged in radial strips, but randomly distributed over the domes. M cell development is restricted to specialized dome-associated crypts. Only dome epithelial cells that derive from these specialized crypts differentiate into M cells. It is concluded that M cells represent a separate cell line that is induced in the dome-associated crypts by still unknown, probably diffusible lymphoid factors. PMID:10329609

  2. Modeling the effects of size on patch dynamics of an inert tracer

    Directory of Open Access Journals (Sweden)

    P. Xiu

    2010-03-01

    Full Text Available Mesoscale iron enrichment experiments have revealed that additional iron affects the phytoplankton productivity and carbon cycle. However, the role of initial size of fertilized patch in determining the patch evolution is poorly quantified due to the limited observational capability and complex of physical processes. Using a three-dimensional ocean circulation model, we simulated different sizes of inert tracer patches that were only regulated by physical circulation and diffusion. Model results showed that during the first few days since release of inert tracer, the calculated dilution rate was found to be a linear function with time, which was sensitive to the initial patch size with steeper slope for smaller size patch. After the initial phase of rapid decay, the relationship between dilution rate and time became an exponential function, which was also size dependent. Therefore, larger initial size patches can usually last longer and ultimately affect biogeochemical processes much stronger than smaller patches.

  3. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-06-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, freestanding electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function.

  4. Engineered hybrid cardiac patches with multifunctional electronics for online monitoring and regulation of tissue function

    Science.gov (United States)

    Feiner, Ron; Engel, Leeya; Fleischer, Sharon; Malki, Maayan; Gal, Idan; Shapira, Assaf; Shacham-Diamand, Yosi; Dvir, Tal

    2016-01-01

    In cardiac tissue engineering approaches to treat myocardial infarction, cardiac cells are seeded within three-dimensional porous scaffolds to create functional cardiac patches. However, current cardiac patches do not allow for online monitoring and reporting of engineered-tissue performance, and do not interfere to deliver signals for patch activation or to enable its integration with the host. Here, we report an engineered cardiac patch that integrates cardiac cells with flexible, free-standing electronics and a 3D nanocomposite scaffold. The patch exhibited robust electronic properties, enabling the recording of cellular electrical activities and the on-demand provision of electrical stimulation for synchronizing cell contraction. We also show that electroactive polymers containing biological factors can be deposited on designated electrodes to release drugs in the patch microenvironment on-demand. We expect that the integration of complex electronics within cardiac patches will eventually provide therapeutic control and regulation of cardiac function. PMID:26974408

  5. Coral Patch seamount (NE Atlantic – a sedimentological and megafaunal reconnaissance based on video and hydroacoustic surveys

    Directory of Open Access Journals (Sweden)

    C. Wienberg

    2013-05-01

    Full Text Available The present study provides new knowledge about the so far largely unexplored Coral Patch seamount which is located in the NE Atlantic Ocean half-way between the Iberian Peninsula and Madeira. For the first time a detailed hydroacoustic mapping (MBES in conjunction with video surveys (ROV, camera sled were performed to describe the sedimentological and biological characteristics of this sub-elliptical ENE-WSW elongated seamount. Video observations were restricted to the southwestern summit area of Coral Patch seamount (water depth: 560–760 m and revealed that this part of the summit is dominated by exposed hard substrate, whereas soft sediment is just a minor substrate component. Although exposed hardgrounds are dominant for this summit area and, thus, offer suitable habitat for settlement by benthic organisms, the benthic megafauna shows rather scarce occurrence. In particular, scleractinian framework-building cold-water corals are apparently rare with very few isolated and small-sized live occurrences of the species Lophelia pertusa and Madrepora oculata. In contrast, dead coral framework and coral rubble are more frequent pointing to a higher abundance of cold-water corals on Coral Patch during the recent past. This is even supported by the observation of fishing lines that got entangled with rather fresh-looking coral frameworks. Overall, long lines and various species of commercially important fish were frequently observed emphasising the potential of Coral Patch as an important target for fisheries that may have impacted the entire benthic community. Hydroacoustic seabed classification covered the entire summit of Coral Patch and its northern and southern flanks (water depth: 560–2660 m and revealed extended areas dominated by mixed and soft sediments at the northern flank and to a minor degree at its easternmost summit and southern flank. Nevertheless, these data also predict most of the summit area to be dominated by exposed bedrock

  6. Patch time allocation and oviposition behavior in response to patch quality and the presence of a generalist predator in Meteorus pulchricornis (Hymenoptera: Braconidae).

    Science.gov (United States)

    Sheng, Sheng; Ling, Meng; Fu-An, Wu; Baoping, Li

    2015-01-01

    Foraging parasitoids often must estimate local risk of predation just as they must estimate local patch value. Here, we investigate the effects a generalist predator Chlaenius bioculatus (Coleoptera: Carabidae), has on the oviposition behavior and the patch residence decisions of a solitary parasitoid Meteorus pulchricornis (Hymenoptera: Braconidae) in response to the varying host quality of Spodoptera litura (Lepidoptera: Noctuidae) larvae (L2 and L4). M. pulchricornis attacked more L4 than on L2 hosts, with the difference in attack rate varying depending on predation treatments, greater in the presence (either actively feeding or not) of the predator than in the absence of it. The parasitoid attacked fewer L2 and L4 hosts when the predator was actively feeding than when it was not feeding or not present in the patch. M. pulchricornis decreased the patch leaving tendency with increasing rejections of hosts, but increased the tendency in response to the presence of the predator as compared with the absence of it, and furthermore, increased the patch leaving tendency when the predator was actively feeding as compared with when it was not. Our study suggests that M. pulchricornis can exploit high quality patches while minimizing predation risk, by attacking more hosts in high quality patches while reducing total patch time in response to risk of predation. © The Author 2015. Published by Oxford University Press on behalf of the Entomological Society of America.

  7. Non-IgE-related diagnostic methods (LST, patch test).

    Science.gov (United States)

    Matsumoto, Kenji

    2015-01-01

    Although most food allergy patients have immediate-type reactions, some have delayed-type reactions. Unlike for the detection of food-specific IgE antibody in immediate-type (IgE-mediated) food allergies, only a few tests are currently available to aid in the diagnosis of delayed-type (non-IgE-mediated) food allergies. This chapter summarizes our current understanding of one in vitro test and one in vivo test for non-IgE-mediated food allergies: the lymphocyte stimulation test (LST) and the atopy patch test (APT). Although the LST is not yet standardized, a food protein-specific LST might be a useful tool for diagnosing delayed-type food allergies, and especially those manifesting with gastrointestinal symptoms but not skin symptoms. Various remaining issues - including basophil contamination of the peripheral blood mononuclear cell fraction and lipopolysaccharide contamination of food antigen preparations - are also discussed. The APT uses an epicutaneous patch technique to occlusively apply food antigens to the skin to induce inflammatory reactions at the patch application site. Because the APT shows modest sensitivity and specificity, the clinical benefit of the APT in the diagnosis of food allergies in patients with atopic dermatitis is limited. A position paper on the APT issued by the European Academy of Allergy and Clinical Immunology/Global Allergy and Asthma European Network in 2006 is briefly summarized, and several recent APT-related topics, including APT use for the diagnosis of food protein-induced enterocolitis syndrome, are discussed. © 2015 S. Karger AG, Basel.

  8. Stability of fragrance patch test preparations applied in test chambers.

    Science.gov (United States)

    Mowitz, M; Zimerson, E; Svedman, C; Bruze, M

    2012-10-01

    Petrolatum patch test preparations are for practical reasons often applied in test chambers in advance, several hours or even days before the patient is tested. As many fragrance compounds are volatile it may be suspected that petrolatum preparations applied in test chambers are not stable over time. To investigate the stability of petrolatum preparations of the seven chemically defined components in the fragrance mix (FM I) when stored in test chambers. Samples of petrolatum preparations applied in test chambers stored at room temperature and in a refrigerator for between 4 and 144 h were analysed using liquid chromatographic methods. The concentration decreased by ≥ 20% within 8 h in four of seven preparations stored in Finn chambers at room temperature. When stored in a refrigerator only the preparation of cinnamal had decreased by ≥ 20% within 24 h. The stability of preparations of cinnamal stored in IQ chambers with a plastic cover was slightly better, but like the preparations applied in Finn chambers, the concentration decreased by ≥ 20% within 4 h at room temperature and within 24 h in a refrigerator. Cinnamal and cinnamyl alcohol were found to be more stable when analysed as ingredients in FM I compared with when analysed in individual preparations. Within a couple of hours several fragrance allergens evaporate from test chambers to an extent that may affect the outcome of the patch test. Application to the test chambers should be performed as close to the patch test occasion as possible and storage in a refrigerator is recommended. © 2012 The Authors. BJD © 2012 British Association of Dermatologists.

  9. Emergent properties of patch shapes affect edge permeability to animals.

    Directory of Open Access Journals (Sweden)

    Vilis O Nams

    Full Text Available Animal travel between habitat patches affects populations, communities and ecosystems. There are three levels of organization of edge properties, and each of these can affect animals. At the lowest level are the different habitats on each side of an edge, then there is the edge itself, and finally, at the highest level of organization, is the geometry or structure of the edge. This study used computer simulations to (1 find out whether effects of edge shapes on animal behavior can arise as emergent properties solely due to reactions to edges in general, without the animals reacting to the shapes of the edges, and to (2 generate predictions to allow field and experimental studies to test mechanisms of edge shape response. Individual animals were modeled traveling inside a habitat patch that had different kinds of edge shapes (convex, concave and straight. When animals responded edges of patches, this created an emergent property of responding to the shape of the edge. The response was mostly to absolute width of the shapes, and not the narrowness of them. When animals were attracted to edges, then they tended to collect in convexities and disperse from concavities, and the opposite happened when animals avoided edges. Most of the responses occurred within a distance of 40% of the perceptual range from the tip of the shapes. Predictions were produced for directionality at various locations and combinations of treatments, to be used for testing edge behavior mechanisms. These results suggest that edge shapes tend to either concentrate or disperse animals, simply because the animals are either attracted to or avoid edges, with an effect as great as 3 times the normal density. Thus edge shape could affect processes like pollination, seed predation and dispersal and predator abundance.

  10. Smooth causal patches for AdS black holes

    Science.gov (United States)

    Raju, Suvrat

    2017-06-01

    We review the paradox of low energy excitations of a black hole in anti-de Sitter space (AdS). An appropriately chosen unitary operator in the boundary theory can create a locally strong excitation near the black hole horizon, whose global energy is small as a result of the gravitational redshift. The paradox is that this seems to violate a general rule of statistical mechanics, which states that an operator with energy parametrically smaller than k T cannot create a significant excitation in a thermal system. When we carefully examine the position dependence of the boundary unitary operator that produces the excitation and the bulk observable necessary to detect the anomalously large effect, we find that they do not both fit in a single causal patch. This follows from a remarkable property of position-space AdS correlators that we establish explicitly and resolves the paradox in a generic state of the system, since no combination of observers can both create the excitation and observe its effect. As a special case of our analysis, we show how this resolves the "Born rule" paradox of Marolf and Polchinski [J. High Energy Phys. 01 (2016) 008, 10.1007/JHEP01(2016)008] and we verify our solution using an independent calculation. We then consider boundary states that are finely tuned to display a spontaneous excitation outside the causal patch of the infalling observer, and we propose a version of causal patch complementarity in AdS/CFT that resolves the paradox for such states as well.

  11. Patch near field acoustic holography based on particle velocity measurements

    DEFF Research Database (Denmark)

    Zhang, Yong-Bin; Jacobsen, Finn; Bi, Chuan-Xing

    2009-01-01

    Patch near field acoustic holography (PNAH) based on sound pressure measurements makes it possible to reconstruct the source field near a source by measuring the sound pressure at positions on a surface. that is comparable in size to the source region of concern. Particle velocity is an alternative...... examines the use of particle velocity as the input of PNAH. Because the particle velocity decays faster toward the edges of the measurement aperture than the pressure does and because the wave number ratio that enters into the inverse propagator from pressure to velocity amplifies high spatial frequencies...

  12. Patch holography using a double layer microphone array

    DEFF Research Database (Denmark)

    Gomes, Jesper Skovhus

    a closed local element mesh that surrounds the microphone array, and with a part of the mesh coinciding with a patch, the entire source is not needed in the model. Since the array has two layers, sources/reflections behind the array are also allowed. The Equivalent Source Method (ESM) is another technique...... in which the sound field is represented by a set of monopoles placed inside the source. In this paper these monopoles are distributed so that they surround the array, and the reconstruction is compared with the IBEM-based approach. The comparisons are based on computer simulations with a planar double...... layer array and sources with different shapes....

  13. Successful application of large microneedle patches by human volunteers

    OpenAIRE

    Ripolin, Anastasia; Quinn, James; Larrañeta, Eneko; Vicente-Perez, Eva Maria; Barry, Johanne; Donnelly, Ryan F.

    2017-01-01

    We describe, for the first time, the design, production and evaluation of large microneedle patches. Such systems, based on 16 individual microneedle arrays (needle height 600??m), were prepared from aqueous blends of 15% w/w Gantrez? S97 and 7.5% w/w poly(ethyleneglycol) 10,000?Da. Ester-based crosslinking was confirmed by FTIR and mechanical strength was good. Insertion depths in a validated skin model were approximately 500??m. Ten human volunteers successfully self-inserted the microneedl...

  14. Performance of patch repaired composite panels under fatigue loads

    International Nuclear Information System (INIS)

    Darwish, Feras H.; Hamoush, S.; Shivakumar, K.

    2006-01-01

    This paper evaluates the performance of bonded patch-scarf repairs of full scale laminated composite panels under cyclic load conditions. Nondestructive testing to characterize the quality of repairs and destructive testing to evaluate the performance of repaired panels were used in this study. Carbon/Epoxy prepreg material used was used to lay up six-ply (12 in. x 27 in. /305x686mm) (-60/60/0) s quasi-isotropic laminates. 7-ply scarf repair with a gradient of 0.5 inch (12.7mm) per layer was used to perform the repair of a damaged zone. The patch consisted of 7.5 inches (190mm) diameter adhesive film, 1 inch (25.4mm) diameter filler ply at 90fiber orientation, and six plies (2-7 inches (51-178mm) diameter) to match the lay-up of the parent material. The study was extended to include defective repairs. The defect was engineered by inserting a 1 inch (25.4 mm) circular Teflon flaw between the fifth and sixth layers of the patch. A total of 28 panels were prepared and divided into five categories: (1) three pristine panels (undamaged parental materials); (2) three damaged panels (1-inch-centered-hole); (3) two repaired panels with wrong fiber orientation; (4) nine good repaired panels, and (5) eleven defective repair panels (1 inch flaw). A nondestructive evaluation to check the conditions of the repairs was performed on most of the tested panels that include the pulse-echo C-scan and pseudo through transmission air coupled and water coupled C-scan. Based on the results of the experimental evaluation of this study, good repair restored 95% of the tensile strength while defective repair restored 90% of the tensile strength of the pristine panels. Under fatigue loading, panels repaired with a 1 inch delamination flaw within the patch layers showed a major reduction in fatigue life compared to the good repair panels under similar loading conditions. (author)

  15. Features of change of permanent snow patches in the Mongun-Taiga Massif, 1966–2011

    Directory of Open Access Journals (Sweden)

    D. A. Ganyushkin

    2013-01-01

    Full Text Available The article is dedicated to perennial snow patches of Mongun-Taiga mountain massif (south-western Tuva, their morphology, present state and dynamics over the last 45 years. We created a scheme of snow patch classification with regard to genesis of relief and position on the slopes. Dynamics of snow patches is analyzed for periods between several time points – 1966 (on basis of aerial photos, 2000, 2007–2008 and 2011 (on basis of field measurements and observations. From 1966 to 2008 the number of snow patches decreased by 4 times, the total area – by 15 times, the altitudinal zone of snow patches moved 250–300 m up. In 2008–2011 the altitudinal zone of snow patches partly recovered, its lower limit moved 250 m down, periglacial snow patches recovered, a new type – snow patches of buried ice and debris-covered glaciers appeared. It could be the first face of the process of small glaciers recovery in the massif. Using the changes of the altitudinal position of snow patches in comparison with data of the closest meteorological station we estimated the amount of annual precipitation, critical for the existence of local snow patches.

  16. The art and science of mission patches and their origins in society

    Science.gov (United States)

    Brumfitt, A.; Thompson, L. A.; Raitt, D.

    2008-06-01

    Space exploration utilizes some of the latest and highest technology available to human kind; synonymous with space exploration is the mission patch. This specialized art form popularizes the exploration of space with millions of mission patches sold around the world. Space tourism and education centres like the Kennedy Space Centre rely heavily on each space shuttle launch to support their merchandising of mission patches, from the traditional sew on badge to T shirts. Do mission patches tell a story? Are they Art? What is the origin and role of this art form in society? The art form of space mission patches combines the 21st century relevance with heraldic origins predating the ninth century. The space mission patch is designed by the astronauts themselves if it is a manned mission. As an education tool teachers and educators use the space mission patch to engage their students in the excitement of space exploration, the mission patch design is utilized as an education tool in literature, science and art. The space mission patch is a particularly powerful message medium. This paper looks at the origins of the space mission patch, its relevance to art and its impact on society.

  17. Tolerability, usability and acceptability of dissolving microneedle patch administration in human subjects.

    Science.gov (United States)

    Arya, Jaya; Henry, Sebastien; Kalluri, Haripriya; McAllister, Devin V; Pewin, Winston P; Prausnitz, Mark R

    2017-06-01

    To support translation of microneedle patches from pre-clinical development into clinical trials, this study examined the effect of microneedle patch application on local skin reactions, reliability of use and acceptability to patients. Placebo patches containing dissolving microneedles were administered to fifteen human participants. Microneedle patches were well tolerated in the skin with no pain or swelling and only mild erythema localized to the site of patch administration that resolved fully within seven days. Microneedle patches could be administered by hand without the need of an applicator and delivery efficiencies were similar for investigator-administration and self-administration. Microneedle patch administration was not considered painful and the large majority of subjects were somewhat or fully confident that they self-administered patches correctly. Microneedle patches were overwhelmingly preferred over conventional needle and syringe injection. Altogether, these results demonstrate that dissolving microneedle patches were well tolerated, easily usable and strongly accepted by human subjects, which will facilitate further clinical translation of this technology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. A missing factor in chip-based patch clamp assay: gigaseal

    International Nuclear Information System (INIS)

    Ong, W-L; Yobas, L; Ong, W-Y

    2006-01-01

    The 'gold' standard in the study of ionic currents across biological membranes is the Patch Clamp method. However, this is a slow, labor and skill intensive process. High throughput patch clamp devices are mainly chip-based. A major challenge in these miniaturized devices is the low rate of 'Gigaseal' formation which is critical in the study of Single Channel effect. In a conventional patch clamp, a pipette moves and patches a fixed cell (cell-adhered patch) which is grown on the bottom of a Petri dish. In the chip-based case, the cells are in suspension and move towards the fixed patch clamp sites (cell-suspended patch). In this study, using the proven conventional patch clamp setup, we investigated the effect of the differences in the cell configurations between the convention patch clamp and cell-based patch clamp. It is shown that adhered cells (as used in the conventional setup) have a much higher rate of gigaseal formation as compared to the cells in suspension (as used in chip-based devices). We postulate that the arrangement of the cytoskeleton within the cell plays a major part in the formation of the gigaseal

  19. Patch testing in children from 2005 to 2012: results from the North American contact dermatitis group.

    Science.gov (United States)

    Zug, Kathryn A; Pham, Anh Khoa; Belsito, Donald V; DeKoven, Joel G; DeLeo, Vincent A; Fowler, Joseph F; Fransway, Anthony F; Maibach, Howard I; Marks, James G; Mathias, C G Toby; Pratt, Melanie D; Sasseville, Denis; Storrs, Frances J; Taylor, James S; Warshaw, Erin M; Zirwas, Matthew J

    2014-01-01

    Allergic contact dermatitis is common in children. Epicutaneous patch testing is an important tool for identifying responsible allergens. The objective of this study was to provide the patch test results from children (aged ≤18 years) examined by the North American Contact Dermatitis Group from 2005 to 2012. This is a retrospective analysis of children patch-tested with the North American Contact Dermatitis Group 65- or 70-allergen series. Frequencies and counts were compared with previously published data (2001-2004) using χ statistics. A total of 883 children were tested during the study period. A percentage of 62.3% had ≥1 positive patch test and 56.7% had ≥1 relevant positive patch test. Frequencies of positive patch test and relevant positive patch test reaction were highest with nickel sulfate (28.1/25.6), cobalt chloride (12.3/9.1), neomycin sulfate (7.1/6.6), balsam of Peru (5.7/5.5), and lanolin alcohol 50% petrolatum vehicle (5.5/5.1). The ≥1 positive patch test and ≥1 relevant positive patch test in the children did not differ significantly from adults (≥19 years) or from previously tested children (2001-2004). The percentage of clinically relevant positive patch tests for 27 allergens differed significantly between the children and adults. A total of 23.6% of children had a relevant positive reaction to at least 1 supplemental allergen. Differences in positive patch test and relevant positive patch test frequencies between children and adults as well as test periods confirm the importance of reporting periodic updates of patch testing in children to enhance clinicians' vigilance to clinically important allergens.

  20. Disentangling the role of seed bank and dispersal in plant metapopulation dynamics using patch occupancy surveys.

    Science.gov (United States)

    Manna, F; Pradel, R; Choquet, R; Fréville, H; Cheptou, P-O

    2017-10-01

    In plants, the presence of a seed bank challenges the application of classical metapopulation models to aboveground presence surveys; ignoring seed bank leads to overestimated extinction and colonization rates. In this article, we explore the possibility to detect seed bank using hidden Markov models in the analysis of aboveground patch occupancy surveys of an annual plant with limited dispersal. Patch occupancy data were generated by simulation under two metapopulation sizes (N = 200 and N = 1,000 patches) and different metapopulation scenarios, each scenario being a combination of the presence/absence of a 1-yr seed bank and the presence/absence of limited dispersal in a circular 1-dimension configuration of patches. In addition, because local conditions often vary among patches in natural metapopulations, we simulated patch occupancy data with heterogeneous germination rate and patch disturbance. Seed bank is not observable from aboveground patch occupancy surveys, hence hidden Markov models were designed to account for uncertainty in patch occupancy. We explored their ability to retrieve the correct scenario. For 10 yr surveys and metapopulation sizes of N = 200 or 1,000 patches, the correct metapopulation scenario was detected at a rate close to 100%, whatever the underlying scenario considered. For smaller, more realistic, survey duration, the length for a reliable detection of the correct scenario depends on the metapopulation size: 3 yr for N = 1,000 and 6 yr for N = 200 are enough. Our method remained powerful to disentangle seed bank from dispersal in the presence of patch heterogeneity affecting either seed germination or patch extinction. Our work shows that seed bank and limited dispersal generate different signatures on aboveground patch occupancy surveys. Therefore, our method provides a powerful tool to infer metapopulation dynamics in a wide range of species with an undetectable life form. © 2017 by the Ecological Society of America.

  1. Colloidal gas aphron foams: A novel approach to a hydrogel based tissue engineered myocardial patch

    Science.gov (United States)

    Johnson, Elizabeth Edna

    Cardiovascular disease currently affects an estimated 58 million Americans and is the leading cause of death in the US. Over 2.3 million Americans are currently living with heart failure a leading cause of which is acute myocardial infarction, during which a part of the heart muscle is damaged beyond repair. There is a great need to develop treatments for damaged heart tissue. One potential therapy involves replacement of nonfunctioning scar tissue with a patch of healthy, functioning tissue. A tissue engineered cardiac patch would be ideal for such an application. Tissue engineering techniques require the use of porous scaffolds, which serve as a 3-D template for initial cell attachment and grow-th leading to tissue formation. The scaffold must also have mechanical properties closely matching those of the tissues at the site of implantation. Our research presents a new approach to meet these design requirements. A unique interaction between poly(vinyl alcohol) and amino acids has been discovered by our lab, resulting in the production of novel gels. These unique synthetic hydrogels along with one natural hydrogel, alginate (derived from brown seaweed), have been coupled with a new approach to tissue scaffold fabrication using solid colloidal gas aphrons (CGAs). CGAs are colloidal foams containing uniform bubbles with diameters on the order of micrometers. Upon solidification the GCAs form a porous, 3-D network suitable for a tissue scaffold. The project encompasses four specific aims: (I) characterize hydrogel formation mechanism, (II) use colloidal gas aphrons to produce hydrogel scaffolds, (III) chemically and physically characterize scaffold materials and (IV) optimize and evaluate scaffold biocompatibility.

  2. Cyclical and patch-like GDNF distribution along the basal surface of Sertoli cells in mouse and hamster testes.

    Directory of Open Access Journals (Sweden)

    Takeshi Sato

    Full Text Available BACKGROUND AND AIMS: In mammalian spermatogenesis, glial cell line-derived neurotrophic factor (GDNF is one of the major Sertoli cell-derived factors which regulates the maintenance of undifferentiated spermatogonia including spermatogonial stem cells (SSCs through GDNF family receptor α1 (GFRα1. It remains unclear as to when, where and how GDNF molecules are produced and exposed to the GFRα1-positive spermatogonia in vivo. METHODOLOGY AND PRINCIPAL FINDINGS: Here we show the cyclical and patch-like distribution of immunoreactive GDNF-positive signals and their close co-localization with a subpopulation of GFRα1-positive spermatogonia along the basal surface of Sertoli cells in mice and hamsters. Anti-GDNF section immunostaining revealed that GDNF-positive signals are mainly cytoplasmic and observed specifically in the Sertoli cells in a species-specific as well as a seminiferous cycle- and spermatogenic activity-dependent manner. In contrast to the ubiquitous GDNF signals in mouse testes, high levels of its signals were cyclically observed in hamster testes prior to spermiation. Whole-mount anti-GDNF staining of the seminiferous tubules successfully visualized the cyclical and patch-like extracellular distribution of GDNF-positive granular deposits along the basal surface of Sertoli cells in both species. Double-staining of GDNF and GFRα1 demonstrated the close co-localization of GDNF deposits and a subpopulation of GFRα1-positive spermatogonia. In both species, GFRα1-positive cells showed a slender bipolar shape as well as a tendency for increased cell numbers in the GDNF-enriched area, as compared with those in the GDNF-low/negative area of the seminiferous tubules. CONCLUSION/SIGNIFICANCE: Our data provide direct evidence of regionally defined patch-like GDNF-positive signal site in which GFRα1-positive spermatogonia possibly interact with GDNF in the basal compartment of the seminiferous tubules.

  3. Evaluation of the Performance of O-rings Made with Different Elastomeric Polymers in Simulated Geothermal Environments at 300°C

    Energy Technology Data Exchange (ETDEWEB)

    Sugama, Toshifumi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pyatina, Tatiana [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Redline, Erica Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); McElhanon, James R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Blankenship, Douglas A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-12-01

    This paper aims to evaluate the survival of O-rings made with six different elastomeric polymers, EPDM, type I- and II-FKM, FEPM, FFKM, and FSR, in five different simulated geothermal environments at 300°C. It further defines the relative strengths and weaknesses of the materials in each environment. The environments tested were: 1) non-aerated steam-cooling cycles, 2) aerated steam-cooling cycles, 3) water-based drilling fluid, 4) CO2-rich geo-brine fluid, and, 5) heat-cool water quenching cycles. Following exposure, the extent of oxidation, oxidationinduced degradation, thermal behaviors, micro-defects, permeation depths of ionic species present in environments throughout the O-ring, silicate-related scale-deposition, and changes in mechanical properties were assessed.

  4. Bio-Inspired Wide-Angle Broad-Spectrum Cylindrical Lens Based on Reflections from Micro-Mirror Array on a Cylindrical Elastomeric Membrane

    Directory of Open Access Journals (Sweden)

    Chi-Chieh Huang

    2014-06-01

    Full Text Available We present a wide-angle, broad-spectrum cylindrical lens based on reflections from an array of three-dimensional, high-aspect-ratio micro-mirrors fabricated on a cylindrical elastomeric substrate, functionally inspired by natural reflecting superposition compound eyes. Our device can perform one-dimensional focusing and beam-shaping comparable to conventional refraction-based cylindrical lenses, while avoiding chromatic aberration. The focal length of our cylindrical lens is 1.035 mm, suitable for micro-optical systems. Moreover, it demonstrates a wide field of view of 152° without distortion, as well as modest spherical aberrations. Our work could be applied to diverse applications including laser diode collimation, barcode scanning, holography, digital projection display, microlens arrays, and optical microscopy.

  5. Small Molecules for Early Endosome-Specific Patch Clamping.

    Science.gov (United States)

    Chen, Cheng-Chang; Butz, Elisabeth S; Chao, Yu-Kai; Grishchuk, Yulia; Becker, Lars; Heller, Stefan; Slaugenhaupt, Susan A; Biel, Martin; Wahl-Schott, Christian; Grimm, Christian

    2017-07-20

    To resolve the subcellular distribution of endolysosomal ion channels, we have established a novel experimental approach to selectively patch clamp Rab5 positive early endosomes (EE) versus Rab7/LAMP1-positive late endosomes/lysosomes (LE/LY). To functionally characterize ion channels in endolysosomal membranes with the patch-clamp technique, it is important to develop techniques to selectively enlarge the respective organelles. We found here that two small molecules, wortmannin and latrunculin B, enlarge Rab5-positive EE when combined but not Rab7-, LAMP1-, or Rab11 (RE)-positive vesicles. The two compounds act rapidly, specifically, and are readily applicable in contrast to genetic approaches or previously used compounds such as vacuolin, which enlarges EE, RE, and LE/LY. We apply this approach here to measure currents mediated by TRPML channels, in particular TRPML3, which we found to be functionally active in both EE and LE/LY in overexpressing cells as well as in endogenously expressing CD11b+ lung-tissue macrophages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The relevance of 7-day patch test reading.

    Science.gov (United States)

    Higgins, Eleanor; Collins, Paul

    2013-01-01

    Patch test readings are usually performed on day 2 (48 hours) and day 4 (96 hours). However, reports in the literature identify delayed allergy to metals, corticosteroids, antibiotics, some preservatives, acrylic and methacrylic monomers and p-phenylenediamine. The aim of our study was to identify the benefit of performing a day 7 (168 hours) reading to identify relevant late positive reactions. Two hundred three consecutive patients were patch tested to the British Society for Cutaneous Allergy standard series with additional test series selected according to clinical history and applied at the same time. Twenty-six patients (12.8%) had new positive reactions on day 7 (168 hours), with 28 relevant positive reactions to 21 allergens. These included mercury 0.5% (2/26); cobalt chloride 1% (2/26); colophony 20% (2/26); disperse blue mix 106/124 1% (2/26); preservatives (4/26) that included Methylchloroisothiazolinone/methylisothiazolinone, sodium metabisulfite, and diazolidinyl urea; fragrances (7/26); and gentamycin sulfate 20% (1/26). These results confirm findings in the literature and support the argument for performing a day 7 reading (168 hours) to identify relevant late positive reactions.

  7. Electrospun biocomposite nanofibrous patch for cardiac tissue engineering

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, Molamma P; Ramakrishna, Seeram [Health Care and Energy Materials Laboratory, Nanoscience and Nanotechnology Initiative, Faculty of Engineering, National University of Singapore, 2 Engineering Drive 3, Singapore 117576 (Singapore); Kai, Dan [NUS Graduate School of Integrative Sciences and Engineering, National University of Singapore (Singapore); Ghasemi-Mobarakeh, Laleh, E-mail: nnimpp@nus.edu.s [Islamic Azad University, Najafabad Branch, Isfahan (Iran, Islamic Republic of)

    2011-10-15

    A bioengineered construct that matches the chemical, mechanical, biological properties and extracellular matrix morphology of native tissue could be suitable as a cardiac patch for supporting the heart after myocardial infarction. The potential of utilizing a composite nanofibrous scaffold of poly(dl-lactide-co-glycolide)/gelatin (PLGA/Gel) as a biomimetic cardiac patch is studied by culturing a population of cardiomyocyte containing cells on the electrospun scaffolds. The chemical characterization and mechanical properties of the electrospun PLGA and PLGA/Gel nanofibers were studied by Fourier transform infrared spectroscopy, scanning electron microscopy and tensile measurements. The biocompatibility of the scaffolds was also studied and the cardiomyocytes seeded on PLGA/Gel nanofibers were found to express the typical functional cardiac proteins such as alpha-actinin and troponin I, showing the easy integration of cardiomyocytes on PLGA/Gel scaffolds. Our studies strengthen the application of electrospun PLGA/Gel nanofibers as a bio-mechanical support for injured myocardium and as a potential substrate for induction of endogenous cardiomyocyte proliferation, ultimately reducing the cardiac dysfunction and improving cardiac remodeling.

  8. Intraventricular Hemorrhage after Epidural Blood Patching: An Unusual Complication

    Directory of Open Access Journals (Sweden)

    Mohammad Sorour

    2014-01-01

    Full Text Available The authors present two cases of intraventricular hemorrhage (IVH believed to be a result of epidural blood patching. The first was a 71-year-old woman who had new onset of nontraumatic IVH on computed tomography (CT scan after undergoing an epidural blood patch (EBP. This amount of intraventricular blood was deemed an incidental finding since it was of very small volume to account for her overall symptoms. The second patient, a 29-year-old woman, was found to have nontraumatic IVH three days after undergoing an EBP. This was seen on CT scan of the head for workup of pressure-like headaches, nausea, vomiting, and absence seizures. Conservative management was followed in both instances. Serial CT scan of the head in our first patient displayed complete resolution of her IVH. The second patient did not have follow-up CT scans because her overall clinical picture had improved significantly. This highlights a potential sequel of EBP that may be observed on CT scan of the head. In the event that IVH is detected, signs and symptoms of hydrocephalus should be closely monitored with the consideration for a future workup if warranted by the clinical picture.

  9. Topical lidocaine patch 5% for acute postoperative pain control.

    LENUS (Irish Health Repository)

    Gilhooly, D

    2011-02-01

    A 39-year-old para 3 woman presented for elective caesarean section (lower segment caesarean section (LSCS)) for breech presentation. The patient had a strong history of atopy and anaphylaxis to paracetamol, codeine, penicillin and latex. The patient was asthmatic, triggered by aspirin. Epidural anaesthesia was unsuccessful and LSCS was carried out under spinal anaesthesia. Postoperatively the patient was unwilling to take analgesic medication due to fear of an allergic reaction. Three 5% lidocaine patches were applied to the wound for postoperative analgesia. This reduced the patient\\'s visual analogue scale pain score from 10\\/10 to 5\\/10 at rest and 10\\/10 to 7\\/10 with movement. Transcutaneous electrical nerve stimulation was added and this improved associated back pain, reducing the pain further to 2\\/10. This is the first description of lignocaine patch 5% for postoperative LSCS pain. It is suggested that this method of delivery of local anaesthetic, which is easy to apply and has minimal side effects, should be considered not as a sole agent but as part of a multimodal technique to address postoperative LSCS pain.

  10. Prevailence of Patch Test Positivity with Some Bases

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1987-01-01

    Full Text Available To evaluate the suitability of some chemicals to act as bases for antigens for patch tests, patch tests were performed with these agents in patients having contact dermatitis. Propylene glycol′used as such produced positive reactions in 25 (50% patients of which 12 were 2 + or more, polyethylene glycol 200 produced positive reactions in 9 (18% cases of which 4 cases were 2 + or more, a mixture of liquid paraffin and hard paraffin gave rise to positive reactions in 10 (10% cases 3 of these being 2 +, a mixture of liquid paraffin and bees wax was positive in 14 (14,Yo cases 3 of these being 2 +, yellow petrolatum was positive in 4 (8% cases, one of which was 2 +, white petrolatum was positive in S (6% cases all of these being + reactions only, and glycerol gave rise to a I + reaction in only one (2% caw. In tropical countries, water should be as base for as many antigens as possible for others, a control test with the b must be included.

  11. Sound insulation performance of plates with interconnected distributed piezoelectric patches

    Directory of Open Access Journals (Sweden)

    Yi Kaijun

    2017-02-01

    Full Text Available This paper deals with the sound insulation performance of a thin plate with interconnected distributed piezoelectric patches. Piezoelectric patches are periodically bonded on the surfaces of the plate in a collocated fashion, and are interconnected via an inductive circuit network. This piezoelectric system is termed as piezo-electromechanical (PEM plate in the paper. Homogenization methods are involved under a sub-wavelength assumption to analytically develop the dynamical equations for the PEM plate. The dispersion relationships and energy densities of the wave modes propagating in the PEM plate are studied; the sub-wavelength assumption is verified for the simulations in this paper. The coincidence frequency of the PEM plate is researched, and results show that the coincidence frequency of the PEM plate will disappear at certain circumstances; mathematical and physical explanations are made for this phenomenon. The disappearance of the coincidence frequency is used to optimize the value of inductance, for the purpose of improving the sound transmission loss of the PEM plate.

  12. Dual-Resonant Implantable Circular Patch Antenna for Biotelemetry Communication

    Directory of Open Access Journals (Sweden)

    Rongqiang Li

    2016-01-01

    Full Text Available A compact broadband implantable circular patch antenna is designed and experimentally demonstrated for Medical Implant Communications Service (MICS band (402–405 MHz. Compared with other similar implantable antennas, the proposed antenna incorporates three advantages for biotelemetry communication. First, it can realize a broad impedance bandwidth by exhibiting dual resonances. Second, it can obtain a compact structure by introducing two arc-shaped slots, a rectangular slot and a circular slot on metal radiating patch. Finally, it can display a friendly shape by using a circular structure. The proposed antenna occupies a volume of about 431.5 mm3 (10.42 × 1.27π mm3, which is a compromise between miniaturization and bandwidth. The measured −10 dB impedance bandwidth is 55 MHz (385–440 MHz. Furthermore, the radiation performance and human body safety consideration of the antenna are examined and characterized.

  13. Surface contact potential patches and Casimir force measurements

    International Nuclear Information System (INIS)

    Kim, W. J.; Sushkov, A. O.; Lamoreaux, S. K.; Dalvit, D. A. R.

    2010-01-01

    We present calculations of contact potential surface patch effects that simplify previous treatments. It is shown that, because of the linearity of Laplace's equation, the presence of patch potentials does not affect an electrostatic calibration of a two-plate Casimir measurement apparatus. Using models that include long-range variations in the contact potential across the plate surfaces, a number of experimental observations can be reproduced and explained. For these models, numerical calculations show that if a voltage is applied between the plates which minimizes the force, a residual electrostatic force persists, and that the minimizing potential varies with distance. The residual force can be described by a fit to a simple two-parameter function involving the minimizing potential and its variation with distance. We show the origin of this residual force by use of a simple parallel capacitor model. Finally, the implications of a residual force that varies in a manner different from 1/d on the accuracy of previous Casimir measurements is discussed.

  14. [In vitro study of the flow duration of antibiotics solutions prepared in elastomeric infusion devices: effect of cold storage for 3 to 7days].

    Science.gov (United States)

    Grangeon-Chapon, C; Robein-Dobremez, M-J; Pin, I; Trouiller, P; Allenet, B; Foroni, L

    2015-09-01

    Within the cystic fibrosis patients' home care, EMERAA network ("Together against Cystic fibrosis in Rhone-Alpes and Auvergne") organizes parenteral antibiotics cures at home prepared in elastomeric infusion devices by hospital pharmacies. However, patients and nurses found that the durations of infusion with these devices were often longer than the nominal duration of infusion indicated by their manufacturer. This study aimed to identify the potential different causes in relation to these discordances. Three hundred and ninety devices of two different manufacturers are tested in different experimental conditions: three antibiotics each at two different doses, duration of cold storage (three days or seven days) or immediate tests without cold storage, preparation and storage of the solution in the device (protocol Device) or transfer in the device just before measurement (protocol Pocket). All tests highlighted a longer flow duration for devices prepared according to the protocol Device versus the protocol Pocket (P=0.004). Flow duration is increased in the case of high doses of antibiotics with high viscosity such as piperacilline/tazobactam. The results of this in vitro study showed the impact of: (1) the time between the filling of the device and the flow of the solution; (2) cold storage of elastomeric infusion devices; (3) concentration of antibiotics and therefore the viscosity of the solution to infuse. It is therefore essential that health care teams are aware of factors, which may lead to longer infusion durations with these infusion devices. When the additional time for infusion remain acceptable, it should be necessary to inform the patient and to relativize these lengthening compared to many benefits that these devices provide for home care. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Laboratory evaluation of the particle size effect on the performance of an elastomeric half-mask respirator against ultrafine combustion particles.

    Science.gov (United States)

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; Yermakov, Michael; McKay, Roy; Haruta, Hiroki; Kimura, Kazushi

    2013-08-01

    This study quantified the particle size effect on the performance of elastomeric half-mask respirators, which are widely used by firefighters and first responders exposed to combustion aerosols. One type of elastomeric half-mask respirator equipped with two P-100 filters was donned on a breathing manikin while challenged with three combustion aerosols (originated by burning wood, paper, and plastic). Testing was conducted with respirators that were fully sealed, partially sealed (nose area only), or unsealed to the face of a breathing manikin to simulate different faceseal leakages. Three cyclic flows with mean inspiratory flow (MIF) rates of 30, 85, and 135 L/min were tested for each combination of sealing condition and combustion material. Additional testing was performed with plastic combustion particles at other cyclic and constant flows. Particle penetration was determined by measuring particle number concentrations inside and outside the respirator with size ranges from 20 to 200 nm. Breathing flow rate, particle size, and combustion material all had significant effects on the performance of the respirator. For the partially sealed and unsealed respirators, the penetration through the faceseal leakage reached maximum at particle sizes >100 nm when challenged with plastic aerosol, whereas no clear peaks were observed for wood and paper aerosols. The particles aerosolized by burning plastic penetrated more readily into the unsealed half-mask than those aerosolized by the combustion of wood and paper. The difference may be attributed to the fact that plastic combustion particles differ from wood and paper particles by physical characteristics such as charge, shape, and density. For the partially sealed respirator, the highest penetration values were obtained at MIF = 85 L/min. The unsealed respirator had approximately 10-fold greater penetration than the one partially sealed around the bridge of the nose, which indicates that the nose area was the primary leak

  16. Foraging Behavior in Golden Hamsters (Mesocricetus Auratus: Effect of the Distance among Multiple Patches

    Directory of Open Access Journals (Sweden)

    Felipe Cabrera

    2008-05-01

    Full Text Available The pattern of travel and the efficiency in foraging behavior was evaluated in four hamsters searching for food within an enclosure with multiple patches. Two different distances among patches were randomly arranged: Near-Patches (10 cm separation and Distant-Patches (21.5 cm separation. Subjects obtained the food by mounting over the cylinders (stations placed in the enclosure of 110 cm2. Results showed that in both, Near and Distant conditions, the distance between responses was longer in late stages of the trials then in early stages. Nonetheless, the most choices to adjacent stations were in Distant-Patches condition, while skips and diagonal-station choices were more frequently showed in the Near-Patches condition.

  17. Vasodilatory effects of exogenous nitric oxide on the brood patch of the Zebra finch (Taeniopygia guttata)

    OpenAIRE

    Södergren, Anna

    2010-01-01

    In birds like the Zebra finch (Taeniopygia guttata) the female, but not the male develop a brood patch upon incubation of eggs. The brood patch functions to increase heat exchange between the bird and the eggs. Development of the brood patch includes de-feathering, increased vascularization and edema formation. The increased vascularization is due to the development of arteriovenous anastomoses, AVA. The AVA are thermoregulatory vessels involved in cold induced vasodilation, CIVD, demonstrate...

  18. A Study on the RF-DC Conversion Efficiency of Microstrip Patch Rectenna

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yang Ha; Youn, Dong Gi; Kim, Kwan Ho [Korea Electrotechnology Research Institute (Korea); Rhee, Young Chul [Kyungnam University (Korea)

    2000-07-01

    We designed and manufactured microstrip patch antenna mainly used in the rectenna and then analysed RF-DC conversion efficiency of wireless power transmission system. We analyse conversion efficiency of load, direction of linear and dual polization rectenna. We found that the maximum efficiency would be about 70% of load and direction in patch type. In conclusion, we found that total conversion efficiency is 64% - 71% in patch Rectenna. (author). 5 refs., 8 figs., 1 tab.

  19. Both population size and patch quality affect local extinctions and colonizations

    OpenAIRE

    Franzén, Markus; Nilsson, Sven G.

    2009-01-01

    Currently, the habitat of many species is fragmented, resulting in small local populations with individuals occasionally dispersing between the remaining habitat patches. In a solitary bee metapopulation, extinction probability was related to both local bee population sizes and pollen resources measured as host plant population size. Patch size, on the other hand, had no additional predictive power. The turnover rate of local bee populations in 63 habitat patches over 4 years was high, with 7...

  20. Patch types in Posidonia oceanica meadows around Corsica. How can we use them in seascape ecology?

    OpenAIRE

    Abadie, Arnaud; Bonacorsi, Marina; Gobert, Sylvie; Lejeune, Pierre; Pergent, Gérard; Pergent-Martini, Christine

    2015-01-01

    The meadows formed by the Mediterranean seagrass Posidonia oceanica are subjected to various natural (e.g., water movement, light availability, sedimentation) and anthropogenic (e.g., anchoring, trawling, fish farms, explosives) phenomena that erode them and create diverse types of patches. The assemblage of the P. oceanica matrix and these patches creates particular seascapes. On the basis of this assessment, we aimed to investigate the importance of the patch type in structuring P. oceanica...

  1. Mechanical Development of a Very Non-Standard Patch Array Antenna for Extreme Environments

    Science.gov (United States)

    Hughes, Richard; Chamberlain, Neil; Jakoboski, Julie; Petkov, Mihail

    2012-01-01

    This paper describes the mechanical development of patch antenna arrays for the Juno mission. The patch arrays are part of a six-frequency microwave radiometer instrument that will be used to measure thermal emissions from Jupiter. The very harsh environmental conditions in Jupiter orbit, as well as a demanding launch environment, resulted in a design that departs radically from conventional printed circuit patch antennas. The paper discusses the development and qualification of the Juno patch array antennas, with emphasis on the materials approach that was devised to mitigate the effects of electron charging in Jupiter orbit.

  2. Correlation of open cell-attached and excised patch clamp techniques.

    Science.gov (United States)

    Filipovic, D; Hayslett, J P

    1995-11-01

    The excised patch clamp configuration provides a unique technique for some types of single channel analyses, but maintenance of stable, long-lasting preparations may be confounded by rundown and/or rapid loss of seal. Studies were performed on the amiloride-sensitive Na+ channel, located on the apical surface of A6 cells, to determine whether the nystatin-induced open cell-attached patch could serve as an alternative configuration. Compared to excised inside-out patches, stable preparations were achieved more readily with the open cell-attached patch (9% vs. 56% of attempts). In both preparations, the current voltage (I-V) relation was linear, current amplitudes were equal at opposite equivalent clamped voltages, and Erev was zero in symmetrical Na+ solutions, indicating similar Na+ activities on the cytosolic and external surfaces of the patch. Moreover, there was no evidence that nystatin altered channel activity in the patch because slope conductance (3-4pS) and Erev (75 mV), when the bath was perfused with a high K:low Na solution (ENa = 80 mV), were nearly equal in both patch configurations. Our results therefore indicate that the nystatin-induced open cell-attached patch can serve as an alternative approach to the excised inside-out patch when experiments require modulation of univalent ions in the cytosol.

  3. Slime moulds use heuristics based on within-patch experience to decide when to leave.

    Science.gov (United States)

    Latty, Tanya; Beekman, Madeleine

    2015-04-15

    Animals foraging in patchy, non-renewing or slowly renewing environments must make decisions about how long to remain within a patch. Organisms can use heuristics ('rules of thumb') based on available information to decide when to leave the patch. Here, we investigated proximate patch-departure heuristics in two species of giant, brainless amoeba: the slime moulds Didymium bahiense and Physarum polycephalum. We explicitly tested the importance of information obtained through experience by eliminating chemosensory cues of patch quality. In P. polycephalum, patch departure was influenced by the consumption of high, and to a much lesser extent low, quality food items such that engulfing a food item increased patch-residency time. Physarum polycephalum also tended to forage for longer in darkened, 'safe' patches. In D. bahiense, engulfment of any food item increased patch residency irrespective of that food item's quality. Exposure to light had no effect on the patch-residency time of D. bahiense. Given that these organisms lack a brain, our results illustrate how the use of simple heuristics can give the impression that individuals make sophisticated foraging decisions. © 2015. Published by The Company of Biologists Ltd.

  4. A clinical study of transdermal contraceptive patch in Thai adolescence women.

    Science.gov (United States)

    Piyasirisilp, Rachatapon; Taneepanichskul, Surasak

    2008-02-01

    To study cycle control, compliance and safety of a transdermal contraceptive patch in adolescent Thai women. Fifty-eight healthy women were assigned to receive 3 cycles of contraceptive patch (ethinyl estradiol 20 microg and norelgestromin 150 microg/day). All participants aged 16-20 years were invited to participate from the family planning clinic at King Chulalongkorn Memorial Hospital. Data were collected on adverse effects, perceived advantages and disadvantages, body weight, blood pressure, patch detachments and compliance. Data were analyzed using mean, percentage and student's t-test. The participants' average age was 19.4 years, height 158.8 cm, weight 51.8 kg, BMI 20.8 Kg/m2. The most location of patch application was the abdomen and the most adverse event was breast tenderness (31.0%) followed by application site reaction, nausea vomiting and headache respectively. The breast symptom was mild in severity. The participants reported decrease in dysmenorrhea and shorter duration of bleeding. There were no significant changes in body weight and blood pressure. The improvement of their facial acne was reported. There were no pregnancies during use and the adhesion of the contraceptive patch is excellent. Partial patch detachment was reported in only 6.9%. No completed patch detachment was found. The present study found an overall positive impression of a new transdermal contraceptive patch. The good compliance and few side effects were demonstrated. The adhesive patch contraceptive was excellent.

  5. Effect of components (polymer, plasticizer and solvent as a variable in fabrication of diclofenac transdermal patch

    Directory of Open Access Journals (Sweden)

    Chetna Modi

    2012-01-01

    Full Text Available Transdermal drug delivery influence consumer acceptance and marked increase in bioavailability of some drugs which undergoes hepatic first-pass metabolism. Fabrication of transdermal patch requires lots of attention regarding the amount of components used for it. Because of varied nature of polymer and plasticizer, transdermal patches have different properties and different drug release. This study is on the basis to evaluate the amount to be needed for fabrication of diclofenac transdermal patch. Study shows that Hydroxy Propyl Methyl Cellulose has great influence on transdermal patch, if it is used alone in combination with glycerin or PEG-4000 plasticizer.

  6. Reducible Dictionaries for Single Image Super-Resolution based on Patch Matching and Mean Shifting

    DEFF Research Database (Denmark)

    Rasti, Pejman; Nasrollahi, Kamal; Orlova, Olga

    2017-01-01

    is taken, and its counterpart from the HR dictionary is passed through an illumination enhancement process. By this technique, the noticeable change of illumination between neighbor patches in the super-resolved image is significantly reduced. The enhanced HR patch represents the HR patch of the super......-resolved image. Finally, to remove the blocking effect caused by merging the patches, an average of the obtained HR image and the interpolated image obtained using bicubic interpolation is calculated. The quantitative and qualitative analyses show the superiority of the proposed technique over the conventional...

  7. NEB in Analysis of Optical Flow 4 x 4 and 6 x 6-Patches

    International Nuclear Information System (INIS)

    Xia, Shengxiang; Liang, Di

    2017-01-01

    We apply the nudged elastic band technique to non-lineal high-dimensional datasets, we analyze spaces of 4 x 4 and 6 x 6 optical flow patches and detect their topological properties. We experimentally prove that subsets of 4 x 4 and 6 x 6 optical flow patches can be modeled a circle, which confirm some results of 4 x 4 and 6 x 6 optical flow patches by using a new method-NEB, and expend Adams et al's result to larger patches of optical flow. (paper)

  8. Global Derivatives

    DEFF Research Database (Denmark)

    Andersen, Torben Juul

    approaches to dealing in the global business environment." - Sharon Brown-Hruska, Commissioner, Commodity Futures Trading Commission, USA. "This comprehensive survey of modern risk management using derivative securities is a fine demonstration of the practical relevance of modern derivatives theory to risk......" provides comprehensive coverage of different types of derivatives, including exchange traded contracts and over-the-counter instruments as well as real options. There is an equal emphasis on the practical application of derivatives and their actual uses in business transactions and corporate risk...... management situations. Its key features include: derivatives are introduced in a global market perspective; describes major derivative pricing models for practical use, extending these principles to valuation of real options; practical applications of derivative instruments are richly illustrated...

  9. Wideband Low Side Lobe Aperture Coupled Patch Phased Array Antennas

    Science.gov (United States)

    Poduval, Dhruva

    Low profile printed antenna arrays with wide bandwidth, high gain, and low Side Lobe Level (SLL) are in great demand for current and future commercial and military communication systems and radar. Aperture coupled patch antennas have been proposed to obtain wide impedance bandwidths in the past. Aperture coupling is preferred particularly for phased arrays because of their advantage of integration to other active devices and circuits, e.g. phase shifters, power amplifiers, low noise amplifiers, mixers etc. However, when designing such arrays, the interplay between array performance characteristics, such as gain, side lobe level, back lobe level, mutual coupling etc. must be understood and optimized under multiple design constraints, e.g. substrate material properties and thicknesses, element to element spacing, and feed lines and their orientation and arrangements with respect to the antenna elements. The focus of this thesis is to investigate, design, and develop an aperture coupled patch array with wide operating bandwidth (30%), high gain (17.5 dBi), low side lobe level (20 dB), and high Forward to Backward (F/B) ratio (21.8 dB). The target frequency range is 2.4 to 3 GHz given its wide application in WLAN, LTE (Long Term Evolution) and other communication systems. Notwithstanding that the design concept can very well be adapted at other frequencies. Specifically, a 16 element, 4 by 4 planar microstrip patch array is designed using HFSS and experimentally developed and tested. Starting from mutual coupling minimization a corporate feeding scheme is designed to achieve the needed performance. To reduce the SLL the corporate feeding network is redesigned to obtain a specific amplitude taper. Studies are conducted to determine the optimum location for a metallic reflector under the feed line to improve the F/B. An experimental prototype of the antenna was built and tested validating and demonstrating the performance levels expected from simulation predictions

  10. Vein Patch Closure Using Below the Knee Greater Saphenous Vein for Femoral Endarterectomy Procedures is Not Always a Safe Choice

    Directory of Open Access Journals (Sweden)

    M. Berner

    Full Text Available : Background: The complication of vein patch rupture is well described after carotid patch angioplasty; however, there is a paucity of data about the safety of vein patch closure in the setting of femoral endarterectomy. Methods/results: From May 2012 to May 2015, 115 femoral endarterectomies with patch closure were performed. A patch rupture occurred in three cases (2.6% with a mortality rate of 66% (2/3. In all cases the greater saphenous vein below the knee was used as patch material. Discussion/conclusion: Vein patches, particularly from small calibre veins, should be excluded in femoral endarterectomy procedures as they pose a substantial risk of rupture. Keywords: Angioplasty, Patch rupture, Femoral artery, Patch, Great saphenous vein

  11. Development of Acne therapeutic hydrogel patches by radiation technology

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Younmook; Nho, Youngchang; Gwon, Huijeong; Park, Jongseok; Kim, Jinkyu; Kim, Yongsoo

    2012-04-15

    In this project, hydrogel patches containing herbal extracts mixture were developed by radiation technology for acne treatment. Propionibacterium acnes (P. acnes), one of the anaerobic bacterium, is the cause of inflammatory acne. To find novel mediation for inflammation of P. acnes, we confirmed the anti-bacterial and anti-inflammatory activities of several herbal extracts against P. acnes. The water extracts from five dried herbs, Phellodendron amurense Rupr., Paeonia lactiflora Pallas., Houttuynia cordata Thumb., Agrimonia pilosa Ledeb. and Glycyrrhiza uralensis Fisch., were mixed into biocompatible polymers and irradiated by using gamma-ray to prepare hydrogels. The hydrogels containing herbal extracts mixture initiated to decrease the growth of P. acnes and reduced the production of pro-inflammatory cytokines, TNF-{alpha}, IL-8, IL-1{beta} and IL-6, in experiment with human monocytic THP-1 cells treated with heat-killed P. acnes at 1 mg/ml of mixture concentration.

  12. Version control of pathway models using XML patches.

    Science.gov (United States)

    Saffrey, Peter; Orton, Richard

    2009-03-17

    Computational modelling has become an important tool in understanding biological systems such as signalling pathways. With an increase in size complexity of models comes a need for techniques to manage model versions and their relationship to one another. Model version control for pathway models shares some of the features of software version control but has a number of differences that warrant a specific solution. We present a model version control method, along with a prototype implementation, based on XML patches. We show its application to the EGF/RAS/RAF pathway. Our method allows quick and convenient storage of a wide range of model variations and enables a thorough explanation of these variations. Trying to produce these results without such methods results in slow and cumbersome development that is prone to frustration and human error.

  13. Active AU Based Patch Weighting for Facial Expression Recognition

    Directory of Open Access Journals (Sweden)

    Weicheng Xie

    2017-01-01

    Full Text Available Facial expression has many applications in human-computer interaction. Although feature extraction and selection have been well studied, the specificity of each expression variation is not fully explored in state-of-the-art works. In this work, the problem of multiclass expression recognition is converted into triplet-wise expression recognition. For each expression triplet, a new feature optimization model based on action unit (AU weighting and patch weight optimization is proposed to represent the specificity of the expression triplet. The sparse representation-based approach is then proposed to detect the active AUs of the testing sample for better generalization. The algorithm achieved competitive accuracies of 89.67% and 94.09% for the Jaffe and Cohn–Kanade (CK+ databases, respectively. Better cross-database performance has also been observed.

  14. Fire creates host plant patches for monarch butterflies

    Science.gov (United States)

    Baum, Kristen A.; Sharber, Wyatt V.

    2012-01-01

    Monarch butterflies (Danaus plexippus) depend on the presence of host plants (Asclepias spp.) within their breeding range for reproduction. In the southern Great Plains, Asclepias viridis is a perennial that flowers in May and June, and starts to senesce by August. It is locally abundant and readily used by monarchs as a host plant. We evaluated the effects of summer prescribed fire on A. viridis and the use of A. viridis by monarch butterflies. Summer prescribed fire generated a newly emergent population of A. viridis that was absent in other areas. Pre-migrant monarch butterflies laid eggs on A. viridis in summer burned plots in late August and September, allowing adequate time for a new generation of adult monarchs to emerge and migrate south to their overwintering grounds. Thus, summer prescribed fire may provide host plant patches and/or corridors for pre-migrant monarchs during a time when host plant availability may be limited in other areas. PMID:22859559

  15. Lecture 11: Systemtap : Patching the linux kernel on the fly

    CERN Multimedia

    CERN. Geneva

    2013-01-01

    The presentation will describe the usage of Systemtap, in CERN Scientific Linux environment. Systemtap is a tool that allows developers and administrators to write and reuse simple scripts to deeply examine the activities of a live Linux system. We will go through the life cycle of a system tap module : creation, packaging, deployment. It will focus on how we used it recently at CERN as a workaround to patch a 0-day. Thomas Oulevey is a member if the IT department at CERN where he is an active member of the Linux team which supports 9’000 servers, 3’000 desktop systems and more than 5’000 active users. Before CERN he worked at the former astrophysics department of CERN, now called the European Southern Observatory, based in Chile. He was used to maintain the core telescope Linux systems and monitoring infrastructure.

  16. Patched bimetallic surfaces are active catalysts for ammonia decomposition.

    Science.gov (United States)

    Guo, Wei; Vlachos, Dionisios G

    2015-10-07

    Ammonia decomposition is often used as an archetypical reaction for predicting new catalytic materials and understanding the very reason of why some reactions are sensitive on material's structure. Core-shell or surface-segregated bimetallic nanoparticles expose outstanding activity for many heterogeneously catalysed reactions but the reasons remain elusive owing to the difficulties in experimentally characterizing active sites. Here by performing multiscale simulations in ammonia decomposition on various nickel loadings on platinum (111), we show that the very high activity of core-shell structures requires patches of the guest metal to create and sustain dual active sites: nickel terraces catalyse N-H bond breaking and nickel edge sites drive atomic nitrogen association. The structure sensitivity on these active catalysts depends profoundly on reaction conditions due to kinetically competing relevant elementary reaction steps. We expose a remarkable difference in active sites between transient and steady-state studies and provide insights into optimal material design.

  17. Development of Acne therapeutic hydrogel patches by radiation technology

    International Nuclear Information System (INIS)

    Lim, Younmook; Nho, Youngchang; Gwon, Huijeong; Park, Jongseok; Kim, Jinkyu; Kim, Yongsoo

    2012-04-01

    In this project, hydrogel patches containing herbal extracts mixture were developed by radiation technology for acne treatment. Propionibacterium acnes (P. acnes), one of the anaerobic bacterium, is the cause of inflammatory acne. To find novel mediation for inflammation of P. acnes, we confirmed the anti-bacterial and anti-inflammatory activities of several herbal extracts against P. acnes. The water extracts from five dried herbs, Phellodendron amurense Rupr., Paeonia lactiflora Pallas., Houttuynia cordata Thumb., Agrimonia pilosa Ledeb. and Glycyrrhiza uralensis Fisch., were mixed into biocompatible polymers and irradiated by using gamma-ray to prepare hydrogels. The hydrogels containing herbal extracts mixture initiated to decrease the growth of P. acnes and reduced the production of pro-inflammatory cytokines, TNF-α, IL-8, IL-1β and IL-6, in experiment with human monocytic THP-1 cells treated with heat-killed P. acnes at 1 mg/ml of mixture concentration

  18. Study of LCP based flexible patch antenna array

    KAUST Repository

    Ghaffar, Farhan A.

    2012-07-01

    Wrapping of a two element LCP based patch antenna array is studied in this work. For the first time, the designed array is bent in both E and H planes to observe the effect on the radiation and impedance performance of the antenna. The 38 GHz simulation results reveal better performance for H plane bending as compared to E plane bending. A 100 um thick substrate is used for the design which is best suited for flexible antenna applications. Gain variations of 1.1 dB and 1.4 dB are observed for the two orientations while a significantly increased impedance bandwidth of 3 % is obtained with H plane wrapping. The design is highly suitable for broadband micro-cellular backhaul applications. © 2012 IEEE.

  19. The 'sniffer-patch' technique for detection of neurotransmitter release.

    Science.gov (United States)

    Allen, T G

    1997-05-01

    A wide variety of techniques have been employed for the detection and measurement of neurotransmitter release from biological preparations. Whilst many of these methods offer impressive levels of sensitivity, few are able to combine sensitivity with the necessary temporal and spatial resolution required to study quantal release from single cells. One detection method that is seeing a revival of interest and has the potential to fill this niche is the so-called 'sniffer-patch' technique. In this article, specific examples of the practical aspects of using this technique are discussed along with the procedures involved in calibrating these biosensors to extend their applications to provide quantitative, in addition to simple qualitative, measurements of quantal transmitter release.

  20. Electrocardiographic Patch Devices and Contemporary Wireless Cardiac Monitoring

    Directory of Open Access Journals (Sweden)

    Erik eFung

    2015-05-01

    Full Text Available Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG, Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable ‘on-body’ ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.