WorldWideScience

Sample records for effluent release sistema

  1. Effluent release limits, sources and control

    International Nuclear Information System (INIS)

    Swindell, G.E.

    1977-01-01

    Objectives of radiation protection in relation to releases. Environmental transfer models for radionuclides. Relationship between releases, environmental levels and doses to persons. Establishment of release limits: Limits based on critical population group concept critical pathway analysis and identification of critical group. Limits based on optimization of radiation protection individual dose limits, collective doses and dose commitments 1) differential cost benefit analysis 2) authorized and operational limits taking account of future exposures. Monitoring of releases to the environment: Objectives of effluent monitoring. Typical sources and composition of effluents; design and operation of monitoring programmes; recording and reporting of monitoring results; complementary environmental monitoring. (orig.) [de

  2. Radiological effluents released from US continental tests, 1961 through 1992. Revision 1

    International Nuclear Information System (INIS)

    Schoengold, C.R.; DeMarre, M.E.; Kirkwood, E.M.

    1996-08-01

    This report documents all continental tests from September 15, 1961, through September 23, 1992, from which radioactive effluents were released. The report includes both updated information previously published in the publicly available May, 1990 report, DOE/NV-317, ''Radiological Effluents Released from Announced US Continental Tests 1961 through 1988'', and effluent release information on formerly unannounced tests. General information provided for each test includes the date, time, location, type of test, sponsoring laboratory and/or agency or other sponsor, depth of burial, purpose, yield or yield range, extent of release (onsite only or offsite), and category of release (detonation-time versus post-test operations). Where a test with simultaneous detonations is listed, location, depth of burial and yield information are given for each detonation if applicable, as well as the specific source of the release. A summary of each release incident by type of release is included. For a detonation-time release, the effluent curies are expressed at R+12 hours. For a controlled releases from tunnel-tests, the effluent curies are expressed at both time of release and at R+12 hours. All other types are listed at the time of the release. In addition, a qualitative statement of the isotopes in the effluent is included for detonation-time and controlled releases and a quantitative listing is included for all other types. Offsite release information includes the cloud direction, the maximum activity detected in the air offsite, the maximum gamma exposure rate detected offsite, the maximum iodine level detected offsite, and the maximum distance radiation was detected offsite. A release summary incudes whatever other pertinent information is available for each release incident. This document includes effluent release information for 433 tests, some of which have simultaneous detonations. However, only 52 of these are designated as having offsite releases

  3. Radiological effluents released from US continental tests, 1961 through 1992. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Schoengold, C.R.; DeMarre, M.E.; Kirkwood, E.M.

    1996-08-01

    This report documents all continental tests from September 15, 1961, through September 23, 1992, from which radioactive effluents were released. The report includes both updated information previously published in the publicly available May, 1990 report, DOE/NV-317, ``Radiological Effluents Released from Announced US Continental Tests 1961 through 1988``, and effluent release information on formerly unannounced tests. General information provided for each test includes the date, time, location, type of test, sponsoring laboratory and/or agency or other sponsor, depth of burial, purpose, yield or yield range, extent of release (onsite only or offsite), and category of release (detonation-time versus post-test operations). Where a test with simultaneous detonations is listed, location, depth of burial and yield information are given for each detonation if applicable, as well as the specific source of the release. A summary of each release incident by type of release is included. For a detonation-time release, the effluent curies are expressed at R+12 hours. For a controlled releases from tunnel-tests, the effluent curies are expressed at both time of release and at R+12 hours. All other types are listed at the time of the release. In addition, a qualitative statement of the isotopes in the effluent is included for detonation-time and controlled releases and a quantitative listing is included for all other types. Offsite release information includes the cloud direction, the maximum activity detected in the air offsite, the maximum gamma exposure rate detected offsite, the maximum iodine level detected offsite, and the maximum distance radiation was detected offsite. A release summary incudes whatever other pertinent information is available for each release incident. This document includes effluent release information for 433 tests, some of which have simultaneous detonations. However, only 52 of these are designated as having offsite releases.

  4. Effluents and releases of tritium from Novo-Voronezh-5 reactor

    International Nuclear Information System (INIS)

    Babenko, A.G.; Mekhedov, B.N.; Podporinova, L.E.; Popov, S.V.; Shalin, A.N.

    1990-01-01

    Results of systematic measurements of tritium concentration within technological systems of reactor of Novo-Voronezh NPP conducted to evaluate tritium effluents and releases and radiation doses to population from these effluents and releases are given. It is shown that 68% concerning tritium total amount were disposed into sewerage while 17% - through vent tube and 15% - with water and steam from secondary circuit systems. Standartized tritium effluents from WWER-1000 reactor for 5 year run constitute 15±1.9 GBq/MWxyear and it corresponds to mean value of effluents for foreign NPPs. Tritium concentration in the atmosphere constituted according to calculations (4.1-20)x10 -5 Bq/l. Conclusion is made about insignificant dose to population from tritium gaseous effluents. Detail study is necessary for dose connected with tritium contained in water effluents

  5. Dose apportionment using statistical modeling of the effluent release

    International Nuclear Information System (INIS)

    Datta, D.

    2011-01-01

    Nuclear power plants are always operated under the guidelines stipulated by the regulatory body. These guidelines basically contain the technical specifications of the specific power plant and provide the knowledge of the discharge limit of the radioactive effluent into the environment through atmospheric and aquatic route. However, operational constraints sometimes may violate the technical specification due to which there may be a failure to satisfy the stipulated dose apportioned to that plant. In a site having multi facilities sum total of the dose apportioned to all the facilities should be constrained to 1 mSv/year to the members of the public. Dose apportionment scheme basically stipulates the limit of the gaseous and liquid effluent released into the environment. Existing methodology of dose apportionment is subjective in nature that may result the discharge limit of the effluent in atmospheric and aquatic route in an adhoc manner. Appropriate scientific basis for dose apportionment is always preferable rather than judicial basis from the point of harmonization of establishing the dose apportionment. This paper presents an attempt of establishing the discharge limit of the gaseous and liquid effluent first on the basis of the existing value of the release of the same. Existing release data for a few years (for example 10 years) for any nuclear power station have taken into consideration. Bootstrap, a resampling technique, has been adopted on this data sets to generate the population which subsequently provide the corresponding population distribution of the effluent release. Cumulative distribution of the population distribution obtained is constructed and using this cumulative distribution, 95th percentile (upper bound) of the discharge limit of the radioactive effluents is computed. Dose apportioned for a facility is evaluated using this estimated upper bound of the release limit. Paper describes the detail of the bootstrap method in evaluating the

  6. Monitoring of released radioactive gaseous and liquid effluent at Rokkasho Reprocessing Plant

    International Nuclear Information System (INIS)

    Oka, M.; Keta, S.; Nagai, S.; Kano, M.; Ishihara, N.; Moriyama, T.; Ogaki, K.; Noda, K.

    2009-01-01

    Rokkasho Reprocessing Plant (RRP) Rokkasho Reprocessing Plant started its active tests with spent fuel at the end of March 2006. When spent fuels are sheared and dissolved, radioactive gaseous effluent and radioactive liquid effluent such as krypton-85, tritium, etc. are released into the environment. In order to limit the public dose as low as reasonably achievable in an efficient way, RRP removes radioactive material by evaporation, rinsing, filtering, etc., and then releases it through the main stack and the sea discharge pipeline that allow to make dispersion and dilution very efficiently. Also, concerning the radioactive gaseous and liquid effluent to be released into the environment, the target values of annual release have been defined in the Safety Rule based on the estimated annual release evaluated at the safety review of RRP. By monitoring the radioactive material in gaseous exhaust and liquid effluent RRP controls it not to exceed the target values. RRP reprocessed 430 tUpr of spent fuel during Active Test (March 2006 to October 2008). In this report, we report about: The outline of gaseous and liquid effluent monitoring. The amount of radioactive gaseous and liquid effluent during the active test. The performance of removal of radioactive materials in gaseous and liquid effluents. The impact on the public from radioactive effluents during the active test. (author)

  7. A history of effluent releases from the Texas A and M University reactor

    Energy Technology Data Exchange (ETDEWEB)

    Bates, E F; Neff, R D; Sandel, P S; Schoenbucher, B [Texas A and M University (United States)

    1974-07-01

    Since 1966 records of radioactive effluents releases from the Texas A and M University Research Reactor have been compiled. These data include particulate activity, noble gases, and liquid effluent releases. Particulate activity releases with half-lives greater than eight days were negligible and are not included in this presentation. Conversion from an MTR plate reactor to a TRIGA fueled reactor was completed in August 1968. Records of effluent releases of Argon-4l and liquids for the past, five years are summarized, in this presentation. These release data are compared to the current limits specified: in 10 CPR 20 and the limits appearing in proposed Appendix.

  8. Studies for improvement of regulatory control on the radioactive effluent released from nuclear facilities

    International Nuclear Information System (INIS)

    Cheong, Jae Hak; Park, H. M.; Song, M. C.; Lee, K. H.; Jang, J. K.; Chun, J. K.; Jeong, K. H.

    2005-05-01

    This report contains the second-year results of the research project titled 'Studies for Improvement of Regulatory Control on the Radioactive Effluent Released from Nuclear Facilities' and mainly provides technical and strategic approaches to improve performance of regulatory control on the gaseous effluent released from domestic nuclear facilities. The main result contained here includes overview and technical bases of radioactive gaseous effluent control (Chapter 1), reconsideration of the sensitivity requirements for measurement of radioactivity in gaseous effluent sample (Chapter 2), uncertainty analysis of the calculated radioactivity in gaseous effluent (Chapter 3), and improvement of quantification method of noble gas releases (Chapter 4). In addition, analysis of the impact due to combined sampling of particulate from multiple release points (Chapter 5), comparison of domestic nuclear reactors gaseous effluent data to foreign PWRs (Chapter 6), standardized sampling technique for collection of gaseous tritium (Chapter 7), and application of Xe-133 equivalent concept to gaseous effluent control (Chapter 8) are also provided. As a whole, this report provides a generic approach to improve the performance of regulatory control on the gaseous effluent. Therefore, actual enforcement of the recommendations should be preceded by establishment of a series of action plans reflecting on the site- and facility-specific design and operational features

  9. Interpretation of the concepts of ALARA and bat for radioactive effluent releases from nuclear installation

    International Nuclear Information System (INIS)

    Chen Xiaoqiu

    2009-01-01

    Based on the understanding of the important concepts of both ALARA and BAT associated with the characteristics of effluent releases from the existing nuclear installations and the abatement techniques for effluents, this paper elaborates the principle of controlling radioactive effluent concentration from nuclear installation, that is based on the BAT focusing on the abatement techniques for effluents, introduces the good practice in the projects, and optimize the effluent releases with account taken of external factors such as the site condition. (authors)

  10. Experience with effluent release from the Omaha V. A. Hospital TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Blotcky, A J [Veterans Administration Hospital (United States)

    1974-07-01

    The effluent release from experiments is controlled by limiting the size of each sample irradiated so that if it was accidentally completely volatized into the closed room, the radioactive concentration would not exceed the permitted limits. The possible releases of Ar-41 and N-16 from the reactor are also considered. The experimentally determined levels of radiation around the Omaha facility are shown. From the data and calculations it was concluded that the levels of effluent release from the Omaha TRIGA are very small.

  11. Experience with effluent release from the Omaha V. A. Hospital TRIGA reactor

    International Nuclear Information System (INIS)

    Blotcky, A.J.

    1974-01-01

    The effluent release from experiments is controlled by limiting the size of each sample irradiated so that if it was accidentally completely volatized into the closed room, the radioactive concentration would not exceed the permitted limits. The possible releases of Ar-41 and N-16 from the reactor are also considered. The experimentally determined levels of radiation around the Omaha facility are shown. From the data and calculations it was concluded that the levels of effluent release from the Omaha TRIGA are very small

  12. Environmental system applied to radioactive liquid effluent release

    International Nuclear Information System (INIS)

    Nisti, Marcelo Bessa

    2009-01-01

    The current environmental administration considers the productive activity as an environmental system, defined as a group of processes, interactions, parameters and factors involved in the production. This mastering dissertation evaluated the release of the liquid radioactive effluents at Instituto de Pesquisas Energeticas e Nucleares (IPEN), under a systemic environmental study. The study evaluated the source term at IPEN in the period from 2004 to 2008, making use of gamma-ray and alpha spectrometry, instrumental neutron activation analysis, liquid phase scintillation and atomic absorption spectrometry. The employed methodologies were verified using samples from the Intercomparison National Program - PNI/IRD and Reference Materials. The facilities that contributed the most in these releases were the Radiopharmaceutical Center (CR) and the Research Reactor Center (CRPq) with an average of 11,4% and 87,4%, respectively, relative to the present radioactive activity. The sewer system releases were within the radioactive protection regulations, showing the effectiveness of IPEN's Radioactive Effluents Monitoring Program. The concentration of the stable elements Ag, Cd, Cr, Fe, Mn, Ni, Pb and Zn was determined in the liquid effluent in ali the samples from the storage tanks TR1 and CR in the period from 2004 to 2008 and in some of the samples of other IPEN's facilities in the period from 2004 to 2007. Among the analyzed effluents, two samples were higher than the stable elements discharge standards established in the state of Sao Paulo, one sample was higher than the required value of the element cadmium and the other higher than required value of the element zinco The storage tank TR1 discharge flow was estimated in 10,9 ± 0,9 m3 h -1 . The dilution factor at discharge point E1 was estimated using a radiotracers the isotopes 3 H, 137 CS, 60 Co, 54 Mn and 65 Zn, which are commonly released into IPEN's sewer system. The executed radiotracer study was carried out

  13. Liquid Effluent Monitoring Information System test plans release 1.2

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  14. Study about the integrated treatment of chemical and radioactive effluents, introducing the zero release concept

    International Nuclear Information System (INIS)

    Mierzwa, Jose Carlos

    1996-01-01

    An Integrated System to the treatment of Chemical and Radioactive Effluents to the Centro Experimental Aramar is proposed and evaluated, introducing the Effluent Zero Release concept, where factors related to the environmental regulation in vigor in the country, as well as the availability of hydrological resources in the place where CEA have been implanted, are considered. Through a literature analysis of the main effluents treatment techniques available nowadays and after a case of study selection, take into account two industrial installations that will be implanted at CEA, it was defined an arrangement to compose the Integrated System to the Treatment of Chemicals and Radioactive Effluents, focusing the Zero Release concept consolidation. A defined arrangement uses a combination among three treatment processes, it means chemical precipitation, reverse osmosis and evaporation, that were experimentally evaluated. The proposed arrangement was evaluated using synthetic effluents, that were prepared based on data from literature and conception documents of the installation considered in this work. Three kinds of effluents were simulated, one arising from a nuclear reactor laundry, one arising from the water refrigeration system and demineralized water production to the nuclear reactor and the other one arising from a nuclear material production laboratory. Each effluent were individually submitted to the selected treatment processes, to get the best operational conditions for each treatment process. The results got during the laboratory assays show that the proposed Integrated System to the Treatment of Chemicals and Radioactive Effluents is feasible, consolidating the Effluent Zero Release concept, which is the proposition of this work. (author)

  15. Assessment of Radioactive Liquid Effluents Release at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Bessa Nisti, Marcelo; Godoy dos Santos, Adir Janete

    2008-01-01

    A continuous effluent monitoring program has been established at IPEN's plant in order to allow an environmental impact assessment due to radioactive liquid effluent discharge to sanitary system. Representative samples of radioactive liquid effluents are analyzed by using high resolution gamma spectroscopy and instrumental neutron activation analysis, facing to Brazilian radioprotection regulatory rules. The results are consolidating yearly in the Institute source-term. In this paper, results of the source-term are presented, concerning to years 2004, 2005 and 2006. The total activity discharged was 8.5xl0 8 Bq, 5.7x10 8 Bq and 2.7xl0 8 Bq, respectively. As the release is strongly dependent on the total amount of the effluent and on the dilution factor, special attention is needed in order to obtain the correct value of that last one. The estimated inside plant dilution factor, considering the recent facilities and the reshaping of the sewerage system was 80, 180 and 130, for period of 2004, 2005 and 2006 discharged liquid radioactive effluent

  16. Principles for limiting releases of radioactive effluents into the environment

    International Nuclear Information System (INIS)

    1986-01-01

    This publication is concerned with the subject of limiting releases of radioactive effluents during normal, controlled operation of nuclear installations. It does not deal with releases from accidents where it is only possible to limit exposures by intervention. In 1978 the IAEA published guidance on the concepts and principles for use by the competent authorities in setting limits for planned releases of radioactive material into the environment (Safety Series No. 45). This publication is a complete revision of Safety Series No. 45 and its Annex

  17. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.0

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  18. Liquid Effluent Monitoring Information System (LEMIS) test plans release 1.1

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  19. Updated on effluents releases of the CEA nuclear fuel cycle facilities - 1995 to 2010 period

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Nelson Luiz Dias [Centro Tecnologico da Marinha em Sao Paulo (CTMSP) Sao Paulo, SP (Brazil)

    2011-07-01

    The environmental impact assessment of the Centro Experimental Aramar (CEA) facilities has been presented in a former work, based on the measured effluent releases data, for the period from 1995 to 2007. This work shows the update up to 2010. The effluents releases to the environment result from the routine operation of CEA nuclear fuel cycle facilities (LEI - Isotopic Enrichment Laboratory, USIDE - Pilot Plant for Industrial Verification of Uranium Enrichment and LABMAT - Nuclear Materials Laboratory). Basically, this work presents the radioactive release source terms, as described at the CEA Effluent Report sent to the National Commission for Nuclear Energy (CNEN) each semester, and a historical assessment of the critical group annual doses from 1995 up to 2010. The assessed doses are compared to the maximum dose constraint as well as to the exemption level specified by CNEN. (author)

  20. Updated on effluents releases of the CEA nuclear fuel cycle facilities - 1995 to 2010 period

    International Nuclear Information System (INIS)

    Ferreira, Nelson Luiz Dias

    2011-01-01

    The environmental impact assessment of the Centro Experimental Aramar (CEA) facilities has been presented in a former work, based on the measured effluent releases data, for the period from 1995 to 2007. This work shows the update up to 2010. The effluents releases to the environment result from the routine operation of CEA nuclear fuel cycle facilities (LEI - Isotopic Enrichment Laboratory, USIDE - Pilot Plant for Industrial Verification of Uranium Enrichment and LABMAT - Nuclear Materials Laboratory). Basically, this work presents the radioactive release source terms, as described at the CEA Effluent Report sent to the National Commission for Nuclear Energy (CNEN) each semester, and a historical assessment of the critical group annual doses from 1995 up to 2010. The assessed doses are compared to the maximum dose constraint as well as to the exemption level specified by CNEN. (author)

  1. Dry washing: the solution for contaminated liquid effluent releases

    International Nuclear Information System (INIS)

    L'homme, D.; Trambouze, P.

    1998-01-01

    The release of wash water used for contaminated garments poses an ever-increasing problem on nuclear sites. Even though the radioactivity is low, it mixes with organic compounds, thus polluting a large quantity of liquid effluents. In many cases, several thousands of m 3 /year per nuclear site are produced, which at times represents more than 30% of the volume of total releases. The conventional dry cleaning process is not a viable option, given that repeated washing cause clothes to fade and the odors are rot removed completely. In order to eliminate releases, STMI has developed, after several years of research with the Technological University of Compiegne, France, a solvent dry washing process for garments used in the nuclear industry. (author)

  2. Reduction of releases of radioactive effluents from light-water-power-reactors in Japan

    International Nuclear Information System (INIS)

    Yoshida, Y.; Itakura, T.; Kanai, T.

    1977-01-01

    Japan Atomic Energy Commission established the dose objectives to the population around the light-water-reactors in May, 1975, based on the ''ALAP'' concept. These values are respectively, 5 mrems per year for total body and 15 mrems per year for thyroid of an individual in the critical group in the environs, due to both gaseous and liquid effluents from LWRs in one site. The present paper describes the implications of the dose objective values, control measures which have been adopted to reduce releases of radioactive materials and related technical developments in Japan. The main control measures for reduction of radioactive gaseous effluents are an installation of a charcoal gas holdup system for decay of noble gases and a supply of clean steam for the gland seal of a turbine in BWR, and a storage tank system allowing decay of noble gases in PWR. For liquid effluents are taken measures to re-use them as the primary coolant. Consequently, the amounts of radioactivity released to the environment from any LWR during normal operation have been maintained under the level to meet the above dose objective values. For research reactors, reduction of release of effluents has also been carried out in a similar way to LWRs. In order to establish the techniques applicable for further reduction, studies are being made on the control measures to reduce leakage of radioiodine, an apparatus for removal of krypton, the treatment of laundry waste and measures to remove the crud in the primary coolant. Presentation is also made on the energy-integrated gas monitor for gaseous effluent and systems of measuring γ dose from radioactive cloud descriminating from natural background, which have been developed for effective monitoring thus reduced environmental dose

  3. Calculation of releases of radioactive materials in gaseous effluents from nuclear-powered merchant ships (NMS-GEFF code)

    International Nuclear Information System (INIS)

    Cardile, F.P.; Bangart, R.L.; Collins, J.T.

    1978-06-01

    The Intergovernmental Maritime Consultative Organization IMCO) is currently preparing guidelines concerning the safety of nuclear-powered merchant ships. An important aspect of these guidelines is the determination of the releases of radioactive material in effluents from these ships and the control exercised by the ships over these releases. To provide a method for the determination of these releases, the NRC staff has developed a computerized model, the NMS-GEFF Code, which is described in the following chapters. The NMS-GEFF Code calculates releases of radioactive material in gaseous effluents for nuclear-powered merchant ships using pressurized water reactors

  4. Liquid Effluent Monitoring Information System test plans releases 2.0 and 3.0

    International Nuclear Information System (INIS)

    Guettler, D.A.

    1995-01-01

    The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Architecture document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  5. The regulation of radioactive effluent release in France (mainly from large nuclear installations)

    International Nuclear Information System (INIS)

    Hebert, Jean.

    1978-01-01

    In parallel with the licensing system for construction and operation of classified or so-called large nuclear installations (INB) there are in France regulations for the release of radioactive effuents from such installations. The regulations applicable to installations other than INBs are not specifically of a nuclear nature, while those covering INBs, which are analysed in this study, in particular, cover effluent release in liquid or gaseous form. The licensing and control procedures for such release are analysed in detail. (NEA) [fr

  6. Characterization and consequences from CEA nuclear fuel cycle facilities effluents releases - 1995 up to 2007 period

    International Nuclear Information System (INIS)

    Ferreira, Nelson Luiz Dias; Fonseca, Lizandra Pereira de Souza

    2009-01-01

    Discharges to the environment of airborne and/or liquid radioactive effluents from the normal operation of nuclear facilities can become a potential source of radiation exposure to humans. The highest exposed members of the public are defined as the critical group. The requirements for the control and monitoring of radioactive discharges to the environment and the degree of environmental monitoring required are linked to the assessed critical group dose. The assessed dose can be compared to dose constraint, which is a fraction of the annual effective dose to members of the public, as well as the level of exemption specified by the National Commission for Nuclear Energy (CNEN). Effluents releases from the Centro Experimental Aramar (CEA) facilities are registered and described at CEA Effluent Report, semestrally sent to CNEN. Basically, that report provides information related to the type and the quantity of chemical and radioactive substances released to the environment due the routine operation of CEA nuclear fuel cycle facilities (LEI - Isotopic Enrichment Laboratory, USIDE - Pilot Plant for Industrial Verification of Uranium Enrichment and LABMAT - Nuclear Materials Laboratory). CEA Annual Effluent Report includes assessment of the annual effective doses for members of the critical group for the CEA site. This work presents the characterization of the radioactive release source terms and a historical of the critical group annual doses from 1995 up to 2007. (author)

  7. Effective equivalent dose in the critical group due to release of radioactive effluents

    International Nuclear Information System (INIS)

    Santos, John W.A. dos; Varandas, Luciana R.; Souza, Denise N.; Souza, Cristiano B.F.; Lima, Sandro Leonardo N.; Mattos, Marcos Fernando M.; Moraes, Jose Adenildo T.

    2005-01-01

    To ensure that the emissions of radioactive material by liquid and gaseous pathways are below applicable limits it is necessary to evaluate the effective equivalent dose in the critical group, which is a magnitude that takes into consideration the modeling used and the terms radioactive activity source. The calculation of this dose considers each radionuclide released by the activity of Nuclear plant, liquid and gaseous by, and the sum of the values obtained is controlled so that this dose does not exceed the goals of the regulatory body, the CNEN and the goals established by the Nuclear power plant. To hit these targets various controls are used such as: controls for effluent monitors instrumentation, environmental monitoring programs, effluent release controls and dose calculation in the environment. According to the findings, it is concluded that during the period of operation of the plants, this dose is below of the required limits

  8. Natural radionuclides in effluents release by a deactivated uranium mine

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Wagner S.; Kelecom, Alphonse; Silva, Ademir X.; Lopes, José M.; Pinto, Carlos E.C.; Py Júnior, Delcy A.; Antunes, Marcos M., E-mail: pereiraws@gmail.com, E-mail: caerjbr@gmail.com, E-mail: wspereira@inb.gov.br, E-mail: delcy@inb.gov.br, E-mail: Antunes@inb.gov.br, E-mail: lararapls@hotmail.com, E-mail: Ademir@nuclear.ufrj.br, E-mail: marqueslopes@yahoo.com.br [Universidade Veiga de Almeida (UVA), Rio de Janeiro, RJ (Brazil); Indústrias Nucleares do Brasil (COMAP.N/FCN/INB), Resende RJ (Brazil). Fábrica de Combustível Nuclear. Coordenação de Meio Ambiente e Proteção Radiológica Ambiental; Universidade Federal Fluminense (LARARA-PLS/UFF), Niterói, RJ (Brazil). Laboratório de Radiobiologia e Radiometria; Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear

    2017-07-01

    The Ore Treatment Unit (OTU) is a mine and deactivated uranium plant in the city of Caldas, Minas Gerais, Brazil. This facility possesses three points of release of liquid effluents containing radionuclides: point 014, 025 and 076. At these points, the values of activity concentrations (AC) of the radionuclides U{sub nat}, {sup 226}Ra, {sup 210}Pb, {sup 232}Th and {sup 228}Ra were analyzed in 2012. The evaluation of point 014 by univariate statistics pointed four groups. [U{sub nat} > {sup 228}Ra > ({sup 226}Ra = {sup 210}Pb) >{sup 232}Th]. The multivariate statistics separated the radionuclides into two groups: [(U{sub nat} and {sup 232}Th) and ({sup 226}Ra, {sup 228}Ra and {sup 210}Pb)]. At point 025, the univariate statistics described three groups: [Un{sub at} > ({sup 228}Ra = {sup 210}Pb) > ({sup 226}Ra = {sup 232}Th)] and the multivariate analysis also described three but different groups: [(U{sub nat} and {sup 228}Ra), ({sup 226}Ra and {sup 210}Pb) and {sup 232}Th]. In turn, point 076 showed another behavior. The univariate analysis showed only two groups: [(U{sub nat}) > ({sup 226}Ra, {sup 228}Ra, {sup 210}Pb, {sup 232}Th)]. Differently, the multivariate statistics defined three groups: [(U{sub nat} and {sup 232}Th), ({sup 226}Ra and {sup 228}Ra) and {sup 210}Pb].Thus, statistical analysis showed that each point has releases of effluents with different characteristics. Both the behaviors of releases, based on multivariate statistics, and of the AC magnitudes, based on the univariate statistics, are different between the points. The only common features were the greater magnitude of uranium and the smaller magnitude of thorium. (author)

  9. Derived release limits for airborne effluents at TRIGA-INR reactor

    International Nuclear Information System (INIS)

    Oprea, I.; Toma, A.; Dulama, C.; Hirica, O.; Mihai, S.; Ana, E.

    2001-01-01

    The deleterious effects of radiation are classified as stochastic and deterministic. There is a finite probability for the occurrence of stochastic effects even at small doses. As the dose is increased, the frequency of such stochastic events increases, but in the absence of other modifying factors, the severity of the resulting changes is not expected to increase. In contrast to these, in case of deterministic effects, the number of killed cells reaches a detection level which constitutes a threshold, the magnitude of which will depend on the chosen injury level. Due to the proportionality between dose and probability and stochastic effects the doses are additive. The probability of individual harmful effects or risk is proportional to effective dose: H E = Σ T w T H T where H T is the equivalent dose in tissue or organ T and w T is the weighting factor for tissue T. ICRP recommended the committed effective dose E (τ) as the effective dose integrated over the time interval τ. If not specified, values of 50 years for adults and 17 years for children are used. Radionuclides in airborne and liquid effluents can result in radiation exposure of man via a number of routes or 'pathways' in the environment. Some pathways, such as ingestion of food, result in internal exposures; others, as for instance, in case of radioactive cloud, result in external exposures. However, the total exposure of an individual via all significant pathways from an source of contaminated effluents, must be taken into account to ensure that the regulatory dose limits are not exceeded. The methodology consists of, first, determining for each radionuclide released from each source the most important pathways with regard to radiation exposure of individuals in various localised groups. The following step is calculation of the maximum release rate (Q M ) corresponding to the individual dose-rate limits for each pathways. Then, for each exposed group, the Q M - values are summed in such a way as to

  10. Derived release limits (DRL's) for airborne and liquid effluents from the Chalk River Nuclear Laboratories during normal operations

    International Nuclear Information System (INIS)

    Palmer, J.F.

    1981-02-01

    Derived release limits (DRL's), based on regulatory dose limits, have been calculated for routine discharges of radioactivity in airborne and liquid effluents from the Chalk River Nuclear Laboratories. Three types of sources of airborne effluents were considered: the NRX/NRU stack, the 61 m stack connected to the 99 Mo production facility, and a roof vent typical of those installed on several buildings on the site. Sources of liquid effluents to the Ottawa River were treated as a single source from the site as a whole. Various exposure pathways to workers on the site and to members of the public outside the site boundary were considered in the calculations. The DRL's represent upper limits for routine emissions of radioactivity from the Chalk River Nuclear Laboratories to the surrounding environment. Actual releases are regulated by Administrative Levels, set lower than the DRL's, and are confirmed by monitoring. (author)

  11. Survey of radioactive effluent releases from byproduct material facilities. Technical report

    International Nuclear Information System (INIS)

    Cook, J.R.

    1981-08-01

    A survey of over 3,000 NRC byproduct material licensees was conducted in late 1980 to collect data on annual effluent releases of radioactivity. The survey was conducted through a questionnaire, which was sent to NRC licensees who handle radioactive material in unsealed form, i.e., research, medical, and industrial institutions. Principal findings from the survey analysis are as follows: More than 98% of the reported annual releases to air (484 to 490) yield calculated average concentrations at the boundary of the unrestricted area that were at 1% or less than the maximum permissible concentration (MPC) of Appendix B, Table II, Column 1 of 10 CFR 20. The largest reported annual release was estimated to yield a concentration that was approximately 12% of MPC, the 5 other releases ranged from 1 to 10% of MPC. All reported annual releases of liquid waste were within the limits specified by NRC with most facilities reporting annual releases of only a fraction of a curie. Based on the data provided by licensees and analyzed in this report, it appears that in general the environmental impacts from research, medical and industrial institutions and organizations licensed by the NRC to possess and use byproduct materials are minimal and correspond to a small fraction of that from natural background

  12. Derived release limits for radionuclides in airborne and liquid effluents for the Whiteshell Nuclear Research Establishment and errata

    International Nuclear Information System (INIS)

    Lemire, A.E.

    1989-08-01

    Radionuclides released to the environment may cause external and internal radiation exposure to man via a number of potential pathways. The resulting radiation dose due to such releases from any operating facility must be kept below dose limits specified in the regulations issued by the Atomic Energy Control Board of Canada. At the Whiteshell Nuclear Research Establishment (WNRE), there is one primary source of liquid effluent to the Winnipeg River via the process water outfall. There are five sources of gaseous effluents: the WR-1 stack; the incinerator stack in the waste management area; the active laboratories building (including the hot cells); the Active-Liquid Waste Treatment Centre; and the compactor-baler in the Waste Management Area. This report presents the methodology and models used to calculate the maximum permissible release rates of radionuclides for each of these sources

  13. Estimation of radionuclide releases in atmosphere from Cernavoda NPP based on continuous gaseous effluent monitoring

    International Nuclear Information System (INIS)

    Bobric, E.; Murgoci, S.; Popescu, I.; Ibadula, R.

    2001-01-01

    Monitoring of gaseous effluents from Cernavoda NPP is performed to assess the environmental impact of the plant operation. The results of the monitoring program are used to evaluate the population doses in order to ensure that the emissions of radionuclides in air are below regulatory limits and radiation doses are maintained ALARA. It complements, but is independent from the Operational Environmental Monitoring Program for Cernavoda NPP. Gaseous effluent monitors provide continuous indication of the radioactivity content in atmospheric emissions. Except for noble gases, these monitors also collect samples for later detailed analysis in the station Health Physics Laboratory. This paper presents the main equipment and the results of the gaseous effluents monitoring program in order to assess the impact of Cernavoda NPP operation and to predict the future releases as function of radionuclides concentrations in CANDU systems, based on the identified trends.(author)

  14. Natural radionuclides in effluents release by a deactivated uranium mine

    International Nuclear Information System (INIS)

    Pereira, Wagner S.; Kelecom, Alphonse; Silva, Ademir X.; Lopes, José M.; Pinto, Carlos E.C.; Py Júnior, Delcy A.; Antunes, Marcos M.; Indústrias Nucleares do Brasil; Universidade Federal Fluminense; Coordenacao de Pos-Graduacao e Pesquisa de Engenharia

    2017-01-01

    The Ore Treatment Unit (OTU) is a mine and deactivated uranium plant in the city of Caldas, Minas Gerais, Brazil. This facility possesses three points of release of liquid effluents containing radionuclides: point 014, 025 and 076. At these points, the values of activity concentrations (AC) of the radionuclides U_n_a_t, "2"2"6Ra, "2"1"0Pb, "2"3"2Th and "2"2"8Ra were analyzed in 2012. The evaluation of point 014 by univariate statistics pointed four groups. [U_n_a_t > "2"2"8Ra > ("2"2"6Ra = "2"1"0Pb) >"2"3"2Th]. The multivariate statistics separated the radionuclides into two groups: [(U_n_a_t and "2"3"2Th) and ("2"2"6Ra, "2"2"8Ra and "2"1"0Pb)]. At point 025, the univariate statistics described three groups: [Un_a_t > ("2"2"8Ra = "2"1"0Pb) > ("2"2"6Ra = "2"3"2Th)] and the multivariate analysis also described three but different groups: [(U_n_a_t and "2"2"8Ra), ("2"2"6Ra and "2"1"0Pb) and "2"3"2Th]. In turn, point 076 showed another behavior. The univariate analysis showed only two groups: [(U_n_a_t) > ("2"2"6Ra, "2"2"8Ra, "2"1"0Pb, "2"3"2Th)]. Differently, the multivariate statistics defined three groups: [(U_n_a_t and "2"3"2Th), ("2"2"6Ra and "2"2"8Ra) and "2"1"0Pb].Thus, statistical analysis showed that each point has releases of effluents with different characteristics. Both the behaviors of releases, based on multivariate statistics, and of the AC magnitudes, based on the univariate statistics, are different between the points. The only common features were the greater magnitude of uranium and the smaller magnitude of thorium. (author)

  15. Limitation of releases of radioactive effluents for nuclear power plants in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Tolksdorf, P.; Buehling, A.

    1981-01-01

    Empirical values relating to the effluents of nuclear power plants in the Federal Republic of Germany are now available. These values cover a period of several years of operation. The measured emissions of radioactive substances are often very much below the maximum permissible values, based on the dose limits for the environment stipulated in the legal regulations. Extensive technical and administrative measures contribute to the reduction of radioactive effluents. Furthermore, additional possibilities for improvement are mentioned which may lead to a further reduction of radioactive effluents. These are derived from investigations into the release of radioactive substances in nuclear power plants. The licensing procedure in the Federal Republic of Germany in fixing discharge limits is outlined. Proposals are made concerning licence values which may be determined for the radioactive effluents in modern standardized nuclear power plants with light-water reactors. The resulting radiation exposures are quoted for a typical nuclear power plant site. (author)

  16. Calculation of releases of radioactive materials in gaseous and liquid effluents from boiling water reactors (BWR-GALE Code)

    International Nuclear Information System (INIS)

    Bangart, R.L.; Bell, L.G.; Boegli, J.S.; Burke, W.C.; Lee, J.Y.; Minns, J.L.; Stoddart, P.G.; Weller, R.A.; Collins, J.T.

    1978-12-01

    The calculational procedures described in the report reflect current NRC staff practice. The methods described will be used in the evaluation of applications for construction permits and operating licenses docketed after January 1, 1979, until this NUREG is revised as a result of additional staff review. The BWR-GALE (Boiling Water Reactor Gaseous and Liquid Effluents) Code is a computerized mathematical model for calculating the release of radioactive material in gaseous and liquid effluents from boiling water reactors (BWRs). The calculations are based on data generated from operating reactors, field tests, laboratory tests, and plant-specific design considerations incorporated to reduce the quantity of radioactive materials that may be released to the environment

  17. Derived release limits for airborne effluents at TRIGA - INR Reactor

    International Nuclear Information System (INIS)

    Toma, A.; Dulama, C.; Hirica, O.; Mihai, S.; Oprea, I.

    2008-01-01

    Beginning from fulfilling the purposes of dose limitation system recommended by ICRP, and now accepted in radiation protection, this paper presents an environmental transfer model to calculate derived release limits for airborne and gaseous radioactive effluents at TRIGA-INR, 14 MW Steady State Reactor, in function on INR-Pitesti site. The methodology consists in determination of the principal exposure pathways for different groups of population and dose calculations for each radionuclide. The characterization of radionuclides transfer to environment was made using the compartmental model. The parameter transfer concept was used to describe the distribution of radionuclides between the different compartments. Atmospheric dispersion was very carefully treated, because it is the primary mechanism of the transfer of radionuclides in the environment and it determines all exposure pathways. Calculation of the atmospheric dispersion was made using ORION-II computer code based on the Gaussian plume model which takes account of site's specific climate and relief conditions. Default values recommended by literature were used to calculate some of the parameters when specific site values were not available. After identification of all transfer parameters which characterize the most important exposure pathways, the release rate corresponding to the individual dose rate limit was calculated. This maximum release rate is the derived release limit for each radionuclide and source. In the paper, the derived release limits are calculated for noble gases, radioiodine and other airborne particulate radionuclides, which can be released on the TRIGA-INR reactor stack, and are important to radiation protection. (authors)

  18. Radiation protection requirements in the limitation of the release of radioactive effluents

    International Nuclear Information System (INIS)

    Beninson, D.

    1978-01-01

    The paper summarizes the requirements of radiation protection, as presented in the new ICRP recommendation, in relation to the limitation of the release of radioactive effluents. The concepts of effective dose equivalent and collective dose equivalent are used in the presentation of the optimization procedures and the dose limitation to individuals. The dose commitment is used for the procedures applied to control future exposures. An appendix describes the basic concepts and quantities used in assessments of human exposures and risks. (author)

  19. Decree No 74-1181 of 31 December 1974 concerning liquid radioactive effluent releases from nuclear installations

    International Nuclear Information System (INIS)

    1975-01-01

    This Decree prescribes the licensing procedure for the release of liquid wastes from nuclear installations as well as the technical supervision of such operations. It does not apply to the transport of radioactive effluents which is governed by the regulations on the transport of dangerous goods. (NEA) [fr

  20. Absorption heat pump integrated in an effluent purification system; Bomba de calor por absorcion integrada a un sistema de purificacion de efluentes

    Energy Technology Data Exchange (ETDEWEB)

    Santoyo, Socrates; Siqueiros, Javier; Heard, Christopher; Santoyo, Edgar [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1996-12-31

    The results derived of the integration of an absorption heat pump to an industrial effluents purification system, are presented. The advantages of these heat pumps with respect to heat pumps by mechanical compression of vapor, as well as the advantages in using absorption heat pumps in simple distillation systems, are mentioned. Finally, a description is made of the equipment designed and built, as well as the results obtained in a preliminary test. [Espanol] Se presentan los resultados derivados de la integracion de una bomba de calor por absorcion a un sistema de purificacion de efluentes industriales. Se mencionan las ventajas de este tipo de bombas de calor con respecto a las de calor por compresion mecanica de vapor, asi como las ventajas de usar bombas de calor en sistemas de destilacion simple. Finalmente, se describe el equipo disenado y construido, asi como los resultados obtenidos de una prueba preliminar.

  1. Absorption heat pump integrated in an effluent purification system; Bomba de calor por absorcion integrada a un sistema de purificacion de efluentes

    Energy Technology Data Exchange (ETDEWEB)

    Santoyo, Socrates; Siqueiros, Javier; Heard, Christopher; Santoyo, Edgar [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    The results derived of the integration of an absorption heat pump to an industrial effluents purification system, are presented. The advantages of these heat pumps with respect to heat pumps by mechanical compression of vapor, as well as the advantages in using absorption heat pumps in simple distillation systems, are mentioned. Finally, a description is made of the equipment designed and built, as well as the results obtained in a preliminary test. [Espanol] Se presentan los resultados derivados de la integracion de una bomba de calor por absorcion a un sistema de purificacion de efluentes industriales. Se mencionan las ventajas de este tipo de bombas de calor con respecto a las de calor por compresion mecanica de vapor, asi como las ventajas de usar bombas de calor en sistemas de destilacion simple. Finalmente, se describe el equipo disenado y construido, asi como los resultados obtenidos de una prueba preliminar.

  2. Radioactive effluent monitoring at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Simpson, O.D.

    1975-01-01

    The Effluent and Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL) has recently upgraded capabilities in the field of monitoring and analysis of radioactive airborne and liquid effluents using the techniques of gamma-ray spectrometry. The techniques and equipment used include remotely-operated, computer-based Ge(Li) spectrometers which obtain data on a real-time basis. Permanent record files are maintained of both the effluent release values and the gamma-ray data from which the release values are calculated. Should values for release levels ever be challenged, the gamma-ray spectral information for any measurement can be recalled and analyzed as needed. Daily effluent release reports are provided to operating personnel which contributes to prompt correction of any operational problems. Monthly, quarterly, and annual reports are compiled which provide inventories of the radionuclides released. A description of the effluent monitoring, reporting and records system developed at INEL for this application will be presented

  3. Regulatory review of releases from HIFAR of radioactive airborne effluent

    International Nuclear Information System (INIS)

    Westall, D.J.; Macnab, D.I.

    1996-01-01

    Full text: The Nuclear Safety Bureau (NSB) was set up by legislation in 1992 as an independent Commonwealth corporate body reporting to the Minister for Health and Family Services. Its functions include monitoring and reviewing the safety of nuclear plant owned or operated by the Australian Nuclear Science and Technology Organisation (ANSTO). The NSB sets requirements for authorisation of the operation of the HIFAR research reactor, and may impose restrictions and conditions on its operation. The authorisation for the operation of HIFAR includes a requirement for arrangements for the treatment, safe storage and disposal of solid, liquid and gaseous radioactive wastes from the reactor. The objective is to establish conditions which would ensure that radiation exposure to plant personnel and the public from radioactive wastes are within acceptable limits and that releases are maintained as low as reasonably achievable. The NSB has developed expectations based on international best practice, against which to review HIFAR's arrangements for satisfying the requirement and achieving the objective. Arrangements for the release of airborne radioactive effluent from HIFAR were reviewed by the NSB as part of an overall review of the upgrade of safety documentation for HIFAR. The NSB's expectations for the review were drawn from the International Atomic Energy Agency (IAEA) Basic Safety Standards (Safety Series No 115-I) and the National Health and Medical Research Council (NHMRC) Recommendations for Limiting Exposure to Ionizing Radiation (1995). These expectations included a hierarchy of primary dose limits, stack discharge limits and reference levels for HIFAR aimed at ensuring that radiation doses to the public due to airborne effluent are less than the national dose limits and ANSTO's dose constraints, and are as low as reasonably achievable. An approach favoured by the operator is to work directly to a primary dose limit using an airborne dispersion computer program to

  4. A real-time positron monitor for the estimation of stack effluent releases from PET medical cyclotron facilities

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar.

    2002-01-01

    Large activities of short-lived positron emitting radiopharmaceuticals are routinely manufactured by modern Medical Cyclotron facilities for positron emission tomography (PET) applications. During radiochemical processing, a substantial fraction of the volatile positron emitting radiopharmaceuticals are released into the atmosphere. An inexpensive, fast response positron detector using a simple positron-annihilation chamber has been developed for real-time assessment of the stack release of positron emitting effluents at the Australian National Medical Cyclotron. The positron detector was calibrated by using a 3.0 ml (1.50 MBq) aliquot of 18 FDG and interfaced to an industrial standard datalogger for the real-time acquisition of stack release data

  5. Order of 4 august 1989 on licensing the release of gaseous radioactive effluents by the Cattenom nuclear production centre (units 3 and 4)

    International Nuclear Information System (INIS)

    1989-08-01

    This Order fixes the conditions and limits of authorised releases of gaseous radioactive effluents from Units 3 and 4 of the Cattenom nuclear power plant. It specifies these are maximum limits, below which the radioactive releases should be as low as possible [fr

  6. A risk-based approach to liquid effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements.

  7. A risk-based approach to liquid effluent monitoring

    International Nuclear Information System (INIS)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements

  8. Order of 30 March 1988 on licensing of gaseous radioactive effluent releases by the Fontenay-aux-Roses Nuclear Research Centre

    International Nuclear Information System (INIS)

    1988-01-01

    This Decree prescribes the documents and information the Fontenay-aux-Roses Nuclear Research Centre must provide to the Central Service for Protection against Ionizing Radiation (SCPRI) and lays down the permissible effluent release limits for the Centre [fr

  9. Effluent Information System (EIS) / Onsite Discharge Information System (ODIS): 1986 executive summary

    International Nuclear Information System (INIS)

    Watanabe, T.

    1987-09-01

    Department of Energy (DOE) data base systems aid DOE-Headquarters and Field Offices in managing the radioactive air and liquid effluents from DOE facilities. Data on effluents released offsite are entered into effluent information system (EIS) and data on effluents discharged onsite and retained onsite are entered into Onsite Discharge Information System (ODIS). This document is a summary of information obtained from the CY 1986 effluent data received from all DOE and DOE contractor facilities and entered in the data bases. Data from previous years are also included. The summary consists of information for effluents released offsite, and information for effluents retained onsite

  10. Tritium effluent removal system

    International Nuclear Information System (INIS)

    Lamberger, P.H.; Gibbs, G.E.

    1978-01-01

    An air detritiation system has been developed and is in routine use for removing tritium and tritiated compounds from glovebox effluent streams before they are released to the atmosphere. The system is also used, in combination with temporary enclosures, to contain and decontaminate airborne releases resulting from the opening of tritium containment systems during maintenance and repair operations. This detritiation system, which services all the tritium handling areas at Mound Facility, has played an important role in reducing effluents and maintaining them at 2 percent of the level of 8 y ago. The system has a capacity of 1.7 m 3 /min and has operated around the clock for several years. A refrigerated in-line filtration system removes water, mercury, or pump oil and other organics from gaseous waste streams. The filtered waste stream is then heated and passed through two different types of oxidizing beds; the resulting tritiated water is collected on molecular sieve dryer beds. Liquids obtained from regenerating the dryers and from the refrigerated filtration system are collected and transferred to a waste solidification and packaging station. Component redundancy and by-pass capabilities ensure uninterrupted system operation during maintenance. When processing capacity is exceeded, an evacuated storage tank of 45 m 3 is automatically opened to the inlet side of the system. The gaseous effluent from the system is monitored for tritium content and recycled or released directly to the stack. The average release is less than 1 Ci/day. The tritium effluent can be reduced by isotopically swamping the tritium; this is accomplished by adding hydrogen prior to the oxidizer beds, or by adding water to the stream between the two final dryer beds

  11. Effluent releases at the TRIGA reactor facility

    Energy Technology Data Exchange (ETDEWEB)

    Whittemore, W L [General Atomic Co., San Diego, CA (United States)

    1974-07-01

    The principal effluent from the operating TRIGA reactors in our facility is argon-41. As monitored by a recording gas and particulate stack monitor, the values shown in the table, the Mark III operating 24 hours per day for very long periods produced the largest amount of radioactive argon. The quantity of 23.7 Ci A-41 when diluted by the normal reactor room ventilation system corresponded to 1.45 x 10{sup -6} {mu}Ci/cc. As diluted in the roof stack stream and the reactor building wake, the concentration immediately outside the reactor building was 25% MPC for an unrestricted area. The continued dilution of this effluent resulted in a concentration of a few percent MPC at the site boundary (unrestricted area) 350 meters from the reactor. (author)

  12. USERDA effluent data collection and reporting program

    International Nuclear Information System (INIS)

    Elle, D.R.; Schoen, A.A.

    1978-01-01

    Effluent and environmental monitoring has been conducted at United States Energy Research and Development Administration (formerly United States Atomic Energy Commission) facilities and sites virtually since the inception of atomic energy research and development. In 1971, computer systems were developed that permitted storage of information and data characterizing each effluent and onsite discharge point and relevant information on sources, effluent treatment and control systems, and discharge data, and serve as ERDA's computer-based management information systems for compiling waste discharge control and monitoring data on radioactivity released as airborne or liquid effluents or liquid discharges to onsite retention basins at ERDA facilities. The information systems and associated data outputs have proved to be an effective internal management tool for identifying effluent control problem areas and for surveying an agencywide Radioactive Effluent Reduction Program. The trend data facilitate the detection of gradual changes in the effectiveness of waste treatment systems, and errors or oversights in monitoring and data handling. Other computer outputs are useful for identifying effluent release points that have significantly higher or lower concentrations or quantities in the discharge stream than were measured the previous year. The year-to-year trend reports and the extensive computer edit and error checks have improved the reliability of the reported effluent data. Adoption of a uniform, centralized reporting system has improved the understanding and credibility of effluent data, and has allowed management to evaluate the effectiveness of effluent control practices at ERDA facilities. (author)

  13. Nuclear reactor effluent monitoring

    International Nuclear Information System (INIS)

    Minns, J.L.; Essig, T.H.

    1993-01-01

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC's program results

  14. Nuclear reactor effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Minns, J.L.; Essig, T.H. [Nuclear Regulatory Commission, Washington, DC (United States)

    1993-12-31

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC`s program results.

  15. Order of 21 October 1988 withdrawing the licence for the release of liquid radioactive effluents by the Cattenom nuclear production centre (units 1 and 2)

    International Nuclear Information System (INIS)

    1988-01-01

    The Court of Justice of the European Communities decided on 22 September 1988 that the Commission of the European Communities had to be notified and give its opinion before the competent authorities of Member States authorised the release of radioactive effluents from a nuclear installation. In compliance with that judgment, this Order repeals an Order of 21 February 1986 licensing such release (NEA) [fr

  16. Characterization of effluents from a high-temperature gas-cooled reactor fuel refabrication plant

    International Nuclear Information System (INIS)

    Judd, M.S.; Bradley, R.A.; Olsen, A.R.

    1975-12-01

    The types and quantities of chemical and radioactive effluents that would be released from a reference fuel refabrication facility for the High-Temperature Gas-Cooled Reactor (HTGR) have been determined. This information will be used to predict the impact of such a facility on the environment, to identify areas where additional development work needs to be done to further identify and quantify effluent streams, and to limit effluent release to the environment

  17. Bromide as chemical tracer to measure the liquid effluent flow at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Silva, Douglas B.; Faustino, Mainara G.; Monteiro, Lucilena R.; Cotrim, Marycel E.B.; Pires, Maria Aparecida F.

    2013-01-01

    Due to recent changes in CONAMA Resolution 357, which occurred through the publication of Resolution 430, on May 13, 2011 that now set standards about the effluent release, IPEN-CNEN/SP initiated several actions to improve the Environmental Monitoring Program (PMA-Q) of stable chemical compounds. Besides various parameters (physical and chemical) established by CONAMA, the submission of an annual pollution inventory report became necessary. The liquid effluent flow measurement is required to implement this inventory. Thereby, this paper describes a study that uses bromide as a chemical tracer. This paper presents the results of 6 tracer releases in IPEN wastewater collection network between 2011 and 2012. Two tracer releases designs were performed: single pulse and continuous releases performed with 1 to 6 hours duration, done by using one single piston pump manufactured by DIONEX. After the release, one fraction of the effluent was collected every 15 minutes at IPEN effluent monitoring station. The tracer concentration in the effluent was analyzed by ion chromatography and flow was calculated considering the dilution in the system and pump flow set up for the release. The flow values were measured in 6 events were determined and evaluated as per Brazilian regulation requirements. Experimental designs to be implemented during 2013 monitoring were also discussed in this paper, contributing to legal compliance and to improve IPEN's Environmental Monitoring Program for stable chemical compounds (PMA-Q). (author)

  18. Gaseous radioactive effluent restrictions, measurement, and minimization at a PET/cyclotron facility

    International Nuclear Information System (INIS)

    Plascjak, P.S.; Kim, K.K.; Googins, S.W.; Meyer, W.C. Jr.

    1993-01-01

    In the US, restrictions on the release of radioactive effluents from PET (positron emission tomography)/cyclotron facilities are typically imposed by State regulatory agencies and may be based on various methodologies and limits published by numerous agencies. This work presents suitable effluent concentration limits for various chemical forms of radioisotopes routinely produced in PET/cyclotron facilities. They were determined by application of metabolic models defined by ICRP 53 and ICRP 26/30 which will result in compliance with effective dose equivalent limits of 100 mrem per year at the release point. The NIH Cyclotron Facility effluent air monitoring system, environmental dosimetry program, and simple, effective systems for radioactive effluent minimization are also described. (orig.)

  19. Facility effluent monitoring plan for the 300 Area Fuels Fabrication Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Brendel, D.F.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring system by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The Fuel Fabrication Facility in the Hanford 300 Area supported the production reactors from the 1940's until they were shut down in 1987. Prior to 1987 the Fuel Fabrication Facility released both airborne and liquid radioactive effluents. In January 1987 the emission of airborne radioactive effluents ceased with the shutdown of the fuels facility. The release of liquid radioactive effluents have continued although decreasing significantly from 1987 to 1990

  20. An estimation of exposure from gaseous and volatile radioactive effluents released from EWA reactor between 1971 and 1975

    International Nuclear Information System (INIS)

    Filipiak, B.; Nowicki, K.

    1979-01-01

    The paper gives an estimation of radiation doses for individuals due to gaseous radioactive effluents released from EWA reactor between 1971 and 1975. The doses were estimated for three organs, three groups of people: adults, teenagers and children and for three of the most important exposure paths: the external radiation from a passing cloud, inhalation and from milk ingestion. The results of calculations indicate that the radiation doses received by individuals living in the vicinity of EWA reactor were much below the limit doses or those due to the background radiation. (author)

  1. ESTE AI (Annual Impacts) - the program for calculation of radiation doses caused by effluents in routine releases to the atmosphere and to the hydrosphere

    International Nuclear Information System (INIS)

    Carny, P.; Suchon, D.; Smejkalova, E.; Fabova, V.

    2009-01-01

    ESTE AI is a program for calculation of radiation doses caused by effluents in routine releases to the atmosphere and to the hydrosphere. Doses to the members of critical groups of inhabitants in the vicinity of NPP are calculated and as a result, critical group is determined. The program enables to calculate collective doses as well. Collective doses to the inhabitants living in the vicinity of the NPP are calculated. ESTE AI calculates doses to the whole population of Slovakia from the effluents of the specific plant. In this calculation, global nuclides are included and assumed, as well. The program enables to calculate and to document beyond-border radiological impacts of effluents caused by routine operation of NPP. ESTE AI was approved by the 'Public Health Authority of the Slovak Republic' and is used as legal instrument by Slovenske elektrarne a.s., NPP Bohunice. (authors)

  2. ESTE AI (Annual Impacts) - the program for calculation of radiation doses caused by effluents in routine releases to the atmosphere and to the hydrosphere

    International Nuclear Information System (INIS)

    Carny, P.; Suchon, D.; Smejkalova, E.; Fabova, V.

    2008-01-01

    ESTE AI is a program for calculation of radiation doses caused by effluents in routine releases to the atmosphere and to the hydrosphere. Doses to the members of critical groups of inhabitants in the vicinity of NPP are calculated and as a result, critical group is determined. The program enables to calculate collective doses as well. Collective doses to the inhabitants living in the vicinity of the NPP are calculated. ESTE AI calculates doses to the whole population of Slovakia from the effluents of the specific plant. In this calculation, global nuclides are included and assumed, as well. The program enables to calculate and to document beyond-border radiological impacts of effluents caused by routine operation of NPP. ESTE AI was approved by the 'Public Health Authority of the Slovak Republic' and is used as legal instrument by Slovenske elektrarne a.s., NPP Bohunice. (authors)

  3. Decree No 74-945 of 6 November 1974 concerning gaseous radioactive effluent releases from large nuclear installations and nuclear installations located on the same site

    International Nuclear Information System (INIS)

    1974-01-01

    This Decree prescribes the licensing for the release of gaseous wastes from nuclear installations as well as the technical supervision of such operations. It does not apply to the transport of radioactive effluents which is governed by the regulations on the transport of dangerous goods. (NEA) [fr

  4. Effluent Treatment Facility tritium emissions monitoring

    International Nuclear Information System (INIS)

    Dunn, D.L.

    1991-01-01

    An Environmental Protection Agency (EPA) approved sampling and analysis protocol was developed and executed to verify atmospheric emissions compliance for the new Savannah River Site (SRS) F/H area Effluent Treatment Facility. Sampling equipment was fabricated, installed, and tested at stack monitoring points for filtrable particulate radionuclides, radioactive iodine, and tritium. The only detectable anthropogenic radionuclides released from Effluent Treatment Facility stacks during monitoring were iodine-129 and tritium oxide. This paper only examines the collection and analysis of tritium oxide

  5. Effluent information system (EIS)/onsite discharge information system (ODIS) 1985 executive summary

    International Nuclear Information System (INIS)

    Watanabe, T.

    1986-09-01

    The Effluent Information System (EIS) and Onsite Discharge Information System (ODIS) are Department of Energy (DOE) data base systems that aid DOE-Headquarters and Field Offices in managing the radioactive air and liquid effluents from DOE facilities. Data on effluents released offsite are entered into EIS and data on effluents discharged onsite and retained onsite are entered into ODIS. This document is a summary of information obtained from the CY 1985 effluent data received from all DOE and DOE contractor facilities and entered in the data bases. Data from previous years are also included. The summary consists of two parts. The first part summarizes information for effluents released offsite, and the second part summarizes information for effluents retained onsite. These summaries are taken from the routine annual reports sent to each DOE Operations Office. Special tabulations or specific data can be supplied upon request. Explanations of the significant changes are included in the EIS and ODIS graphic sections. Only those changes in activity greater than a factor of two and having a magnitude greater than 0.1 Ci are considered significant and are addressed in the explanation

  6. A study of effluent control technologies employed by radiopharmaceutical users and suppliers

    International Nuclear Information System (INIS)

    Leventhal, L.; Slider, J.; Chakoff, E.; Chen, J.I.; Savage, E.

    1980-01-01

    The quantities of radiopharmaceuticals produced for in-vivo diagnostic and therapy procedures has been estimated to be growing at the rate of 16% per year, based on 1978 sales figures. Nuclear medicine facilities are experiencing an average annual growth rate of 5% per year. The principle radionuclides produced and used for nuclear medicine are 131 I, 131 Xe, and sup(9m)Tc. Of particular concern is that amount of these radionuclides which might become airborne and escape into the environment during the process of manufacture or during aliquotting or administration by hospital personnel. Therefore, a study was made of the effluent control technology employed by radiopharmaceutical suppliers and users. Generally, the means used to control airborne radioactive effluents fall into two classes according to function. The controls either dilute and direct the effluent to a specific point of release or hold up the effluent to reduce by decay the amount of radioactivity released. Radiopharmaceutical suppliers and hospitals were contacted, and a survey made of the control technology used. The classes and types of effluent control equipment and their general characteristics, cost and effectiveness were determined. It was concluded that control equipment was readily available, reliable, and effective in reducing radioactive releases from radiopharmaceutical facilities. (author)

  7. Monitoring of noble gas radioisotopes in nuclear power plant effluents

    International Nuclear Information System (INIS)

    Kabat, M.J.

    1985-01-01

    Monitoring of gaseous radionuclides in the effluents of nuclear facilities is an essential requirement in effluent management programs. Since there is no practical way of removing noble gas radioisotopes from air at release pathways, their accurate monitoring is essential for providing appropriate environmental protection. Emitted γ dose-rate is the limiting factor for concentration-time integral of noble gas in gaseous effluents of reactor facilities. The external exposure to the public from a semi-infinite cloud is directly proportional to both the noble gas isotope concentration and the integrated γ energy per disintegration. Both can be directly measured in gaseous effluent pathways with a suitable detector. The capability of NaI(T1), CaF 2 (Eu) and plastic scintillation detectors to measure the γ-Ci.MeV content of noble gas releases was experimentally evaluated. The combination of CaF 2 (Eu) detector in a pressurized through-flow chamber, with a charge integrating scaler well complied with both γ energy response and detection sensitivity requirements. Noble gas source terms and effluent monitoring criteria are discussed, theoretical and experimental results are presented and a practical, on-line noble gas monitoring system is described

  8. Fusion fuel cycle: material requirements and potential effluents

    International Nuclear Information System (INIS)

    Teofilo, V.L.; Bickford, W.E.; Long, L.W.; Price, B.A.; Mellinger, P.J.; Willingham, C.E.; Young, J.K.

    1980-10-01

    Environmental effluents that may be associated with the fusion fuel cycle are identified. Existing standards for controlling their release are summarized and anticipated regulatory changes are identified. The ability of existing and planned environmental control technology to limit effluent releases to acceptable levels is evaluated. Reference tokamak fusion system concepts are described and the principal materials required of the associated fuel cycle are analyzed. These materials include the fusion fuels deuterium and tritium; helium, which is used as a coolant for both the blanket and superconducting magnets; lithium and beryllium used in the blanket; and niobium used in the magnets. The chemical and physical processes used to prepare these materials are also described

  9. Fusion fuel cycle: material requirements and potential effluents

    Energy Technology Data Exchange (ETDEWEB)

    Teofilo, V.L.; Bickford, W.E.; Long, L.W.; Price, B.A.; Mellinger, P.J.; Willingham, C.E.; Young, J.K.

    1980-10-01

    Environmental effluents that may be associated with the fusion fuel cycle are identified. Existing standards for controlling their release are summarized and anticipated regulatory changes are identified. The ability of existing and planned environmental control technology to limit effluent releases to acceptable levels is evaluated. Reference tokamak fusion system concepts are described and the principal materials required of the associated fuel cycle are analyzed. These materials include the fusion fuels deuterium and tritium; helium, which is used as a coolant for both the blanket and superconducting magnets; lithium and beryllium used in the blanket; and niobium used in the magnets. The chemical and physical processes used to prepare these materials are also described.

  10. Radioactive and electron microscope analysis of effluent monitor sample lines

    International Nuclear Information System (INIS)

    Kowalski, J.F.

    1986-01-01

    Effluent air sampling at nuclear power plant often leads to the question ''How representative is the sample of the effluent stream?'' Samples from radiation monitors are typically obtained at great distances from the sample nozzle because of high background concerns under postulated accidents. Sample line plateout during normal effluent sampling becomes the major concern. A US Nuclear Regulatory Commission inspection raised a concern that monitors were not collecting representative samples per ANSI standard N13.1. A comprehensive 2-yr study at Beaver Valley was performed during normal effluent releases in two phases: 1) weekly charcoal and glass fiber filter samples were analyzed for radioactivity for 6 months, and 2) nuclepore membrane filter samples were analyzed by electron microscope for 4- and 6-h periods. A specially designed test nozzle was directly inserted into an effluent stream for comparison with the radiation monitor samples. Particle behavior characteristics can be determined during effluent releases using a simple test probe. While particle plateout was the major purpose of the study, other particle behavior characteristics were evident and equally as important. Particle travel through long sample lines can also lead to (a) agglomeration or the coagulation of smaller particles to form larger ones, (b) particle splitting or fracturing upon impact with the sample line interior walls, and (c) resuspension of large particles in sample lines

  11. PWR-GALE, Radioactive Gaseous Release and Liquid Release from PWR

    International Nuclear Information System (INIS)

    Chandrasekaran, T.; Lee, J.Y.; Willis, C.A.

    1988-01-01

    1 - Description of program or function: The PWR-GALE (Boiling Water Reactor Gaseous and Liquid Effluents) Code is a computerized mathematical model for calculating the release of radioactive material in gaseous and liquid effluents from pressurized water reactors (PWRs). The calculations are based on data generated from operating reactors, field tests, laboratory tests, and plant-specific design considerations incorporated to reduce the quantity of radioactive materials that may be released to the environment. 2 - Method of solution: GALE calculates expected releases based on 1) standardized coolant activities derived from ANS Standards 18.1 Working Group recommendations, 2) release and transport mechanisms that result in the appearance of radioactive material in liquid and gaseous waste streams, 3) plant-specific design features used to reduce the quantities of radioactive materials ultimately released to the environs, and 4) information received on the operation of nuclear power plants. 3 - Restrictions on the complexity of the problem: The liquid release portion of GALE uses subroutines taken from the ORIGEN (CCC-217) to calculate radionuclide buildup and decay during collection, processing, and storage of liquid radwaste. Memory requirements for this part of the program are determined by the large nuclear data base accessed by these subroutines

  12. Liquid Effluent Monitoring Information System (LEMIS) System Construction

    International Nuclear Information System (INIS)

    Adams, R.T.

    1994-01-01

    The liquid effluent sampling program is part of the effort to minimize adverse environmental impact during the cleanup operation at the Hanford Site. Of the 33 Phase I and Phase II liquid effluents, all streams actively discharged to the soil column will be sampled. The Liquid Effluent Monitoring Information System (LEMIS) is being developed as the organized information repository facility in support of the liquid effluent monitoring requirements of the Tri-Party Agreement. It is necessary to provide an automated repository into which the results from liquid effluent sampling will be placed. This repository must provide for effective retention, review, and retrieval of selected sample data by authorized persons and organizations. This System Construction document is the aggregation of the DMR P+ methodology project management deliverables. Together they represent a description of the project and its plan through four Releases, corresponding to the definition and prioritization of requirements defined by the user

  13. Siting considerations for radioactivity in reactor effluents during normal operation

    International Nuclear Information System (INIS)

    Graf, J.M.; Strom, P.O.

    1975-01-01

    In selecting a proper site for a nuclear power station, the consideration of radioactivity released in effluents can be handled in a straightforward manner using the U. S. Atomic Energy Commission's proposed Appendix I to 10 CFR 50, which gives numerical guidelines for design objectives for meeting the criterion ''as low as practicable'' for radioactive material in light-water-cooled nuclear power reactor effluents. By relating the release of radioactive material, the site meteorological conditions, and site boundary distance through appropriate dose models, the suitability of a given site can be determined. ''Rules of thumb'' for comparing anticipated releases to design objectives can be constructed for rapid assessment using the maximum permissible concentration values of 10 CFR 20 as dose factors. These rules of thumb tend to underpredict the allowed releases except in the case of radiocesium in liquids. For gaseous releases, these rules of thumb can be made up in convenient nomogram form for a quick assessment of allowed releases based on local site meteorological conditions. (U.S.)

  14. XOQDOQ, Meteorological Evaluation of Atmospheric Nuclear Power Plant Effluents

    International Nuclear Information System (INIS)

    Sagendorf, J.F.; Goll, J.T.; Sandusky, W.F.; Eyberger, L.R.

    1990-01-01

    1 - Description of program or function: XOQDOQ was designed for meteorological evaluation of continuous and anticipated intermittent releases from commercial nuclear power reactors. It calculates annual relative effluent concentrations and average relative deposition values at locations specified by the user and at various standard radial distances and segments for downwind sectors. It also calculates these values at the specified locations for anticipated intermittent (e.g. containment or purge) releases, which occur during routine operation. The program computes an effective plume height that accounts for physical release height, aerodynamic down-wash, plume rise, and terrain features. The user may optionally select additional plume dispersion due to building wakes, plume depletion via dry deposition, and plume radioactive decay, or specify adjustments to represent non-straight line trajectories (recirculation or stagnation). 2 - Method of solution: XOQDOQ is based on the principle that diffusion of material released to the atmosphere can be described by a Gaussian distribution within the plume with transport described by a straight-line trajectory. The horizontal and vertical dispersion coefficients are empirically determined, largely from observations at or near ground level. The program implements the assumptions outlined in Section C of NRC Regulatory Guide 1.111. Long-term average values of relative effluent concentration are calculated by assuming a long-term continuous release with effluent distributed evenly across a 22-1/2 degree sector. 3 - Restrictions on the complexity of the problem - Maxima of: 30 receptor locations/receptor type, 14 wind-speed classes, 10 distances of site-specific recirculation correction factors, 8 receptor types, 7 atmospheric stability categories, 5 separate release points. XOQDOQ cannot handle multiple emission sources or plume depletion via wet deposition, or evaluate the meteorological aspects of the consequences of

  15. Graphic overview system for DOE's effluent and environmental monitoring programs

    International Nuclear Information System (INIS)

    Burson, Z.G.; Elle, D.R.

    1980-03-01

    The Graphic Overview System is a compilation of photos, maps, overlays, and summary information of environmental programs and related data for each DOE site. The information consists of liquid and airborne effluent release points, on-site storage locations, monitoring locations, aerial survey results, population distributions, wind roses, and other related information. The relationships of different environmental programs are visualized through the use of colored overlays. Trends in monitoring data, effluent releases, and on-site storage data are also provided as a corollary to the graphic display of monitoring and release points. The results provide a working tool with which DOE management (headquarters and field offices) can place in proper perspective key aspects of all environmental programs and related data, and the resulting public impact of each DOE site

  16. Calculation of tritium release from reactor's stack

    International Nuclear Information System (INIS)

    Akhadi, M.

    1996-01-01

    Method for calculation of tritium release from nuclear to environment has been discussed. Part of gas effluent contain tritium in form of HTO vapor released from reactor's stack was sampled using silica-gel. The silica-gel was put in the water to withdraw HTO vapor absorbed by silica-gel. Tritium concentration in the water was measured by liquid scintillation counter of Aloka LSC-703. Tritium concentration in the gas effluent and total release of tritium from reactor's stack during certain interval time were calculated using simple mathematic formula. This method has examined for calculation of tritium release from JRR-3M's stack of JAERI, Japan. From the calculation it was obtained the value of tritium release as much as 4.63 x 10 11 Bq during one month. (author)

  17. Radioactive effluents in the Savannah River: Summary report for 1989

    International Nuclear Information System (INIS)

    Winn, W.G.

    1991-09-01

    Researchers at the Savannah River Site have low-level radiometric studies of the Savannah River to distinguish between the effluent contributions of the Savannah River Site and Plant Vogtle. Since the startup of Plant Vogtle in 1987, researchers have routinely detected neutron-activated isotopes in controlled releases, but all have routinely detected neutron-activated isotopes in controlled releases, but all have been well below the Department of Energy's (DOE) guidelines. The study has found that processing improvement at Plant Vogtle during 1989 have lowered the activities of effluents from Plant Vogtle. These studies will continue on a routine basis because they provide disturbing trends before actual health concerns evolve

  18. Application of reverse osmosis to the treatment of liquid effluents produced by nuclear power plants

    International Nuclear Information System (INIS)

    Huet, Y.; Poulat, B.; Menjeaud, C.

    1989-01-01

    Radioactive liquid effluents generated during the operation of PWR nuclear power units are currently treated by two independent systems. The effluents from the reactor coolant system are recycled, unlike the others, which, after treatment, are released into the river or ocean that provides cooling water for the unit. The objective of the treatment of nonrecycled effluents is to separate from them as much of the radioactive particles that they contain as possible, so as to release into the environment a maximum volume of nonradioactive waste, and to be left with only a minimum volume of concentrated waste, containing most of the initial radioactivity, which must be loaded into casks for storage. Membrane-based filtration techniques, because they have excellent separation performances, can logically be used for this decontamination of the liquid effluents. Having developed its own reverse osmosis membrane, a possible application in a nuclear power plant, i.e., integration of a reverse osmosis unit into a radioactive liquid effluent treatment system is presented. (author)

  19. Effects of a surfacing effluent plume on a coastal phytoplankton community

    KAUST Repository

    Reifel, Kristen M.

    2013-06-01

    Urban runoff and effluent discharge from heavily populated coastal areas can negatively impact water quality, beneficial uses, and coastal ecosystems. The planned release of treated wastewater (i.e. effluent) from the City of Los Angeles Hyperion Wastewater Treatment Plant, located in Playa del Rey, California, provided an opportunity to study the effects of an effluent discharge plume from its initial release until it could no longer be detected in the coastal ocean. Non-metric multi-dimensional scaling analysis of phytoplankton community structure revealed distinct community groups based on salinity, temperature, and CDOM concentration. Three dinoflagellates (Lingulodinium polyedrum, Cochlodinium sp., Akashiwo sanguinea) were dominant (together >50% abundance) prior to the diversion. Cochlodinium sp. became dominant (65-90% abundance) within newly surfaced wastewater, and A. sanguinea became dominant or co-dominant as the effluent plume aged and mixed with ambient coastal water. Localized blooms of Cochlodinium sp. and A. sanguinea (chlorophyll a up to 100mgm-3 and densities between 100 and 2000cellsmL-1) occurred 4-7 days after the diversion within the effluent plume. Although both Cochlodinium sp. and A. sanguinea have been occasionally reported from California waters, blooms of these species have only recently been observed along the California coast. Our work supports the hypothesis that effluent and urban runoff discharge can stimulate certain dinoflagellate blooms. All three dinoflagellates have similar ecophysiological characteristics; however, small differences in morphology, nutrient preferences, and environmental requirements may explain the shift in dinoflagellate composition. © 2013 Elsevier Ltd.

  20. Palisades Nuclear Plant. Radioactive effluents and environmental monitoring sections to second annual operating report

    International Nuclear Information System (INIS)

    1977-01-01

    A total of 0.435 Ci of radioactive liquid effluent less tritium was released with 19.63 Ci of tritium. Both liquid and gaseous releases were within permissible limits. There were 8 Ci of solid wastes stored on the site as of 12/31/76. Data clearly shows there was no detectable increase in radioactivity levels in the environmental media that can be attributed to plant effluents. Monitoring reports are presented concerning fish, meteorology, noise, and cooling tower drift

  1. CY-1981 effluent monitoring report

    International Nuclear Information System (INIS)

    Honkus, R.J.

    1982-05-01

    The effluent monitoring programs at ICPP for calendar year 1981 are summarized. During the year, five significant occurrences or unplanned releases occurred. These are briefly described and tabulated. In none of the instances were the applicable Radiation Concentration Guides (RCG's) exceeded. A graphic summary of the total airborne, liquid and solid releases during CY-1981 is presented. Liquid waste activity was higher than anticipated due to various processing factors throughout the year. Solid waste jumped dramatically in December due to shipment of end-prices from the EBR-II fuel which was processed during the Electrolytic campaign

  2. Offsite dose calculation manual guidance: Standard radiological effluent controls for boiling water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-- 01, which allows Radiological Effluent Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft form for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. 11 tabs

  3. Surry Power Station, Units 1 and 2. Annual operating report: January--December 1977, volume I--introduction, summary of operating experience; changes, tests, experiments, and safety-related maintenance; effluent releases; data tabulations

    International Nuclear Information System (INIS)

    1978-01-01

    A chronological operating sequence including shutdowns and occurrences during the year which required load reductions or resulted in non-load related incidents is given. Data are presented concerning plant and procedure changes, tests, experiments, safety related maintenance, effluent releases and personnel radiation exposures

  4. Facility effluent monitoring plan for K Area Spent Fuel. Revision 1

    International Nuclear Information System (INIS)

    Hunacek, G.S.

    1995-09-01

    The scope of this document includes program plans for monitoring and characterizing radioactive and nonradioactive hazardous materials discharged in the K Area effluents. This FEMP includes complete documentation for both airborne and liquid effluent monitoring systems that monitor radioactive and nonradioactive hazardous pollutants that could be discharged to the environment under routine and/or upset conditions. This documentation is provided for each K Area facility that uses, generates, releases, or manages significant quantities of radioactive and nonradioactive hazardous materials that could impact public and employee safety and the environment. This FEW describes the airborne and liquid effluent paths and the associated sampling and monitoring systems of the K Area facilities. Sufficient information is provided on the effluent characteristics and the effluent monitoring systems so that a compliance assessment against requirements may be performed. Adequate details are supplied such that radioactive and hazardous material source terms may be related to specific effluent streams which are, in turn, related to discharge points and finally compared to the effluent monitoring system capability

  5. Facility effluent monitoring plan for the 324 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 324 Facility [Waste Technology Engineering Laboratory] in the 300 Area primarily supports the research and development of radioactive and nonradioactive waste vitrification technologies, biological waste remediation technologies, spent nuclear fuel studies, waste mixing and transport studies, and tritium development programs. All of the above-mentioned programs deal with, and have the potential to, release hazardous and/or radioactive material. The potential for discharge would primarily result from (1) conducting research activities using the hazardous materials, (2) storing radionuclides and hazardous chemicals, and (3) waste accumulation and storage. This report summarizes the airborne and liquid effluents, and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterizing effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  6. A guide for preparing Hanford Site facility effluent monitoring plans

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1992-06-01

    This document provides guidance on the format and content of effluent monitoring plans for facilities at the Hanford Site. The guidance provided in this document is designed to ensure compliance with US Department of Energy (DOE) Orders 5400.1 (DOE 1988a), 5400.3 (DOE 1989a), 5400.4 (DOE 1989b), 5400.5 (DOE 1990a), 5480.1 (DOE 1982), 5480.11 (DOE 1988b), and 5484.1 (DOE 1981). These require environmental monitoring plans for each site, facility, or process that uses, generates, releases, or manages significant pollutants of radioactive or hazardous materials. In support of DOE Orders 5400.5 (Radiation Protection of the Public and the Environment) and 5400.1 (General Environmental Protection Program), the DOE Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance (DOE 1991) should be used to establish elements of a radiological effluent monitoring program in the Facility Effluent Monitoring Plan. Evaluation of facilities for compliance with the US Environmental Protection Agency Clean Air Act of 1977 requirements also is included in the airborne emissions section of the Facility Effluent Monitoring Plans. Sampling Analysis Plans for Liquid Effluents, as required by the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), also are included in the Facility Effluent Monitoring Plans. The Facility Effluent Monitoring Plans shall include complete documentation of gaseous and liquid effluent sampling and monitoring systems

  7. Facility Effluent Monitoring Plan for the N Reactor

    International Nuclear Information System (INIS)

    Watson, D.J.; Brendel, D.F.; Shields, K.D.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP- 0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years. The primary purpose of the N Reactor Facility Effluent Monitoring Plan (FEMP), during standby, is to ensure that the radioactive effluents are properly monitored and evaluated for compliance with the applicable DOE orders and regulatory agencies at the federal, state, and local levels. A secondary purpose of the FEMP is to ensure that hazardous wastes are not released, in liquid effluents, to the environment even though the potential to do so is extremely low. The FEMP is to provide a monitoring system that collects representative samples in accordance with industry standards, performs analyses within stringent quality control (QC) requirements, and evaluates the data through the use of comparative analysis with the standards and acceptable environmental models

  8. Treatment and processing of the effluents and wastes (other than fuel) produced by a 900 MWe nuclear power plant

    International Nuclear Information System (INIS)

    Giraud

    1983-01-01

    Effluents produced by a 900 MWe power plant, are of three sorts: gaseous, liquid and solid. According to their nature, effluents are either released or stored for decaying before being released to the atmosphere. The non-contaminated reactor coolant effluents are purified (filtration, gas stripping) and treated by evaporation for reuse. Depending upon their radioactive level, liquid waste is either treated by evaporation or discharged after filtration. Solid waste issuing from previous treatments (concentrates, resins, filters) is processed in concrete drums using an encapsulation process. The concrete drum provides biological self-protection consistent with the national and international regulations pertaining to the transport of radioactive substance. Finally, the various low-level radioactive solid waste collected throughout the plant, is compacted into metal drums. Annual estimates of the quantity of effluents (gaseous, liquid) released in the environment and the number of drums (concrete, metal) produced by the plant figure in the conclusion

  9. Summarization of radioactive effluent monitoring in Daya Bay Nuclear Power Station 1994-2002

    International Nuclear Information System (INIS)

    Ouyang Junjie; Chen Yue

    2004-01-01

    This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10 4 , noble gas 2.03 x 10 4 , halogen 0.13, aerosol 7.57 x 10 -3 . For 110m Ag, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997

  10. Alternatives for biodigester effluent treatment: economic impact; Impacto economico de um sistema de tratamento dos efluentes de biodigestores

    Energy Technology Data Exchange (ETDEWEB)

    Miele, Marcelo; Kunz, Airton; Correa, Juliano Corulli; Steinmetz, Ricardo [EMBRAPA Suinos e Aves, Concordia, SC (Brazil)], email: marcelo@cnpsa.embrapa.br; Bortoli, Marcelo [Universidade Federal de Santa Catarina, (UFSC), Florianopolis, SC (Brazil)

    2011-07-01

    The aim of this study was to present a prospective economic impact assessment of a biodigester liquid effluent treatment system. This system developed by Embrapa Swine and Poultry is composed by a N removal module and a P one, which can be attached to a biodigester, technology widely diffused in Brazil. Biodigesters do not remove nutrients (NPK) with high pollution potential of water resources and demanding high effluent transport costs. The analysis was based on Net Present Value (NPV) technique, using prototype performance information, market prices and wastewater analysis. The N module reduces more than ten times the surface needed to spread effluents. The P module attains the standard for discharge in water resources and makes this element available as fertilizer. The system has a significant impact on swine production costs, what can be reduced in farms which produces its own energy from manure. High effluent distribution costs also turn treatment more attractive. The study concludes that this is a promising technology which has to be validated. Financial support is needed to implement a real scale prototype to validate it. (author)

  11. Spatio-temporal variations in the composition of organic matter in surface sediments of a mangrove receiving shrimp farm effluents (New Caledonia)

    International Nuclear Information System (INIS)

    Aschenbroich, Adélaïde; Marchand, Cyril; Molnar, Nathalie; Deborde, Jonathan; Hubas, Cédric; Rybarczyk, Hervé; Meziane, Tarik

    2015-01-01

    In order to investigate spatio-temporal variations in the composition and origin of the benthic organic matter (OM) at the sediment surface in mangrove receiving shrimp farm effluents, fatty acid (FA) biomarkers, natural stable isotopes (δ 13 C and δ 15 N), C:N ratios and chlorophyll-a (chl-a) concentrations were determined during the active and the non-active period of the farm. Fatty acid compositions in surface sediments within the mangrove forest indicated that organic matter inputs varied along the year as a result of farm activity. Effluents were the source of fresh particulate organic matter for the mangrove, as evidenced by the unsaturated fatty acid (UFA) distribution. The anthropogenic MUFA 18:1ω9 was not only accumulated at the sediment surface in some parts of the mangrove, but was also exported to the seafront. Direct release of bacteria and enhanced in situ production of fungi, as revealed by specific FAs, stimulated mangrove litter decomposition under effluent runoff condition. Also, microalgae released from ponds contributed to maintain high benthic chl-a concentrations in mangrove sediments in winter and to a shift in microphytobenthic community assemblage. Primary production was high whether the farm released effluent or not which questioned the temporary effect of shrimp farm effluent on benthic microalgae dynamic. This study outlined that mangrove benthic organic matter was qualitatively and quantitatively affected by shrimp farm effluent release and that responses to environmental condition changes likely depended on mangrove stand characteristics. - Highlights: • Fatty acid 18:1ω9 is a relevant marker to monitor effluent pathway in the mangrove. • OM nature and distribution at sediment surface varied in relation to farm activity. • Enhancement of litter-decomposer biomass and activity stimulates litter degradation. • Diatoms dominate the microalgae community under effluent runoff conditions. • Chl-a concentrations suggest

  12. Spatio-temporal variations in the composition of organic matter in surface sediments of a mangrove receiving shrimp farm effluents (New Caledonia)

    Energy Technology Data Exchange (ETDEWEB)

    Aschenbroich, Adélaïde, E-mail: adelaide.aschenbroich@univ-brest.fr [UMR BOREA 7208 CNRS/MNHN/UPMC/IRD/UCBN, Muséum National d' Histoire Naturelle, CP 53, 61 rue Buffon, 75231 Paris cedex 5 (France); Marchand, Cyril [Institut de Recherche pour le Développement (IRD), UMR 7590, UR 206, BP A5, 98848 Nouméa, New Caledonia (France); Molnar, Nathalie [UMR BOREA 7208 CNRS/MNHN/UPMC/IRD/UCBN, Muséum National d' Histoire Naturelle, CP 53, 61 rue Buffon, 75231 Paris cedex 5 (France); Institut de Recherche pour le Développement (IRD), UMR 7590, UR 206, BP A5, 98848 Nouméa, New Caledonia (France); Deborde, Jonathan [Institut de Recherche pour le Développement (IRD), UMR 7590, UR 206, BP A5, 98848 Nouméa, New Caledonia (France); Hubas, Cédric; Rybarczyk, Hervé; Meziane, Tarik [UMR BOREA 7208 CNRS/MNHN/UPMC/IRD/UCBN, Muséum National d' Histoire Naturelle, CP 53, 61 rue Buffon, 75231 Paris cedex 5 (France)

    2015-04-15

    In order to investigate spatio-temporal variations in the composition and origin of the benthic organic matter (OM) at the sediment surface in mangrove receiving shrimp farm effluents, fatty acid (FA) biomarkers, natural stable isotopes (δ{sup 13}C and δ{sup 15}N), C:N ratios and chlorophyll-a (chl-a) concentrations were determined during the active and the non-active period of the farm. Fatty acid compositions in surface sediments within the mangrove forest indicated that organic matter inputs varied along the year as a result of farm activity. Effluents were the source of fresh particulate organic matter for the mangrove, as evidenced by the unsaturated fatty acid (UFA) distribution. The anthropogenic MUFA 18:1ω9 was not only accumulated at the sediment surface in some parts of the mangrove, but was also exported to the seafront. Direct release of bacteria and enhanced in situ production of fungi, as revealed by specific FAs, stimulated mangrove litter decomposition under effluent runoff condition. Also, microalgae released from ponds contributed to maintain high benthic chl-a concentrations in mangrove sediments in winter and to a shift in microphytobenthic community assemblage. Primary production was high whether the farm released effluent or not which questioned the temporary effect of shrimp farm effluent on benthic microalgae dynamic. This study outlined that mangrove benthic organic matter was qualitatively and quantitatively affected by shrimp farm effluent release and that responses to environmental condition changes likely depended on mangrove stand characteristics. - Highlights: • Fatty acid 18:1ω9 is a relevant marker to monitor effluent pathway in the mangrove. • OM nature and distribution at sediment surface varied in relation to farm activity. • Enhancement of litter-decomposer biomass and activity stimulates litter degradation. • Diatoms dominate the microalgae community under effluent runoff conditions. • Chl-a concentrations suggest

  13. Sellafield (release of radioactivity)

    Energy Technology Data Exchange (ETDEWEB)

    Cunningham, J; Goodlad, A; Morris, M

    1986-02-06

    A government statement is reported, about the release of plutonium nitrate at the Sellafield site of British Nuclear Fuels plc on 5 February 1986. Matters raised included: details of accident; personnel monitoring; whether radioactive material was released from the site; need for public acceptance of BNFL activities; whether plant should be closed; need to reduce level of radioactive effluent; number of incidents at the plant.

  14. Application of the dose limitation system to the control of carbon-14 releases from heavy-water-moderated reactors

    International Nuclear Information System (INIS)

    Beninson, D.; Gonzalez, A.J.

    1982-01-01

    Heavy-water-moderated reactors produce substantially more carbon-14 than light-water reactors. Applying the principles of the systems of dose limitation, the paper presents the rationale used for establishing the release limit for effluents containing this nuclide and for the decisions made regarding the effluent treatment in the third nuclear power station in Argentina. Production of carbon-14 in PHWR and the release routes are analysed in the light of the different effluent treatment possibilities. An optimization assessment is presented, taking into account effluent treatment and waste management costs, and the collective effective dose commitment due to the releases. The contribution of present carbon-14 releases to future individual doses is also analysed in the light of an upper bound for the contribution, representing a fraction of the individual dose limits. The paper presents the resulting requirements for the effluent treatment regarding carbon-14 and the corresponding regulatory aspects used in Argentina. (author)

  15. Environmental releases for calendar year 1997

    International Nuclear Information System (INIS)

    Gleckler, B.P.

    1998-01-01

    This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Order 5400.1. This report provides supplemental information to the Hanford Site Environmental Report (PNNL-11795). The Hanford Site Environmental Report provides an update on the environmental status of the Hanford Site. The sitewide annual report summarizes the degree of compliance with applicable environmental regulations and informs the public concerning the impact of Hanford Site operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (FDH), and Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data on air emissions, liquid effluents, and hazardous substances released to the environment during calendar year 1997. Comprehensive data summaries of air emissions and liquid effluents in 1997 are displayed in Tables ES-1 through ES-5. These tables represent the following: Table ES-1--Radionuclide air emissions data (detailed data on emissions are presented in Section 2.0); Table ES-2--Data on radioactive liquid effluents discharged to the soil (detailed data are presented in Section 3.0); Table ES-3--Radionuclides discharged to the Columbia River (detailed data are presented in Section 3.0); Table ES-4--Nonradioactive air emissions data (detailed data are presented in Section 2.0); Table ES-5--Total Volumes and Flow Rates of 200/600 Area Radioactive Liquid Effluents (detailed data are presented in Section 3.0)

  16. Antimicrobial resistant Escherichia coli in the municipal wastewater system: effect of hospital effluent and environmental fate.

    Science.gov (United States)

    Harris, Suvi; Morris, Carol; Morris, Dearbhaile; Cormican, Martin; Cummins, Enda

    2014-01-15

    The prevalence of antimicrobial resistant (AMR) bacteria is increasing worldwide and remains a significant medical challenge which may lead to antimicrobial redundancy. The contribution of hospital effluent to the prevalence of resistance in wastewater treatment plant (WWTP) effluents is not fully understood. AMR bacteria contained in hospital effluent may be released into the aquatic and soil environments after WWTP processing. Hence, the objective of this study is to identify the extent hospital effluent contributes to contamination of these environments by comparing two WWTPs, one which receives hospital effluent and one which does not. AMR Escherichia coli were monitored in the two WWTPs. A model was developed using these monitored values to predict the effect of hospital effluent within a WWTP. The model predicted levels of AMR E. coli in the aquatic environment and potential bather exposure to AMR E. coli. The model results were highly variable. WWTP influent containing hospital effluent had a higher mean percentage of AMR E. coli; although, there appeared to be no within treatment plant effect on the prevalence of AMR E. coli. Examination of WWTP sludge showed a similar variation. There appeared to be no consistent effect from the presence of hospital effluent. The human exposure assessment model predicted swimmer intake of AMR E. coli between 6 and 193CFU/100ml sea water. It appears that hospital effluent is not the main contributing factor behind the development and persistence of AMR E. coli within WWTPs, although resistance may be too well-developed to identify an influence from hospital effluent. Mitigation needs to focus on the removal of already present resistant bacteria but for new or hospital specific antimicrobials focus needs to be on their limited release within effluents or separate treatment. © 2013.

  17. Rework of process effluents from the fabrication of HTR fuel

    International Nuclear Information System (INIS)

    Lasberg, Ingo; Braehler, Georg; Boyes, David

    2008-01-01

    HTR fuel facilities require the application of several liquid chemicals and accordingly they produce significant amounts of Uranium contaminated/potentially contaminated effluents. The main effluents are (amounts for a 3 t Uranium/a plant): aqueous solutions including tetrahydrofurfuryl alcohol THFA, ammonium hydroxide NH4OH, and ammonium nitrate NH4NO3 (180 m 3 /a), isopropanol IPA/water mixtures (130 m 3 /a); Non-Process Water NPW (300 m 3 /a); methanol (7m 3 /a); additionally off-gas streams, containing ammonia (9 t/a) have to be treated. In an industrial scale facility all such effluents/gases need to be processed for recycling, decontamination prior to release to the environment (as waste or as valuable material). Thermal decomposition is applied to dispose of burnable residues.

  18. UNC Nuclear Industries reactor and fuels production facilities 1985 effluent release report

    International Nuclear Information System (INIS)

    Rokkan, D.J.

    1986-01-01

    Analyses of routine samples from radioactive liquid and airborne streams were performed using UNC's Radioanalytical Laboratory and the analytical services of US Testing Company. All significant effluent discharges from UNC facilities to the environment during CY 1985 are reported in this document

  19. Performance of Azolla caroliniana Willd. and Salvinia auriculata Aubl. on fish farming effluent.

    Science.gov (United States)

    Toledo, J J; Penha, J

    2011-02-01

    The increasing release of untreated fish farming effluents into water courses that flow to the Pantanal wetlands in Mato Grosso (Brazil) may drive this ecosystem to eutrophication. Therefore, the growth of Azolla caroliniana Willd. and Salvinia auriculata Aubl. in fish farming effluent and their effect on its quality were evaluated for 48 days in a greenhouse. The results were compared to those obtained in a nutrient rich solution (Hoagland ½ medium). Azolla caroliniana showed lower relative growth rate in fish farming effluent (0.020 d-1) than in Hoagland ½ medium (0.029 d-1). However, S. auriculata grew slightly better in fish farming effluent (0.030 d-1) than in Hoagland ½ medium (0.025 d-1). The species apparently contributed to reduce nitrate and phosphate concentration in Hoagland ½ medium. However, in fish farming effluent, only electrical conductivity and pH were reduced by plants compared to the control without plants. Thus, A. caroliniana and S. auriculata show low potential for improving effluent quality.

  20. Collective dose to the European Community from nuclear industry effluents discharge in 1978

    CERN Document Server

    Camplin, W C

    1983-01-01

    The results are presented of a study to evaluate the collective dose commitment to the population of the European Community from effluents released by the nuclear industry within the EC in 1978. Airborne and liquid effluent discharge data have been taken from published sources, and computer modelling techniques have been used to predict the transfer of radioactivity through the environment to man. The collective dose commitments due to discharges from each nuclear installation have been evaluated and the comparative significance of individual radionuclides and their pathways to man have been considered. Airborne releases resulted in an estimated collective effective dose equivalent commitment of 95 man Sv, the major part of which is due to carbon-14 from both power stations and reprocessing plants. The collective effective dose equivalent commitment from liquid effluents is estimated to be 408 man Sv, mostly due to caesium-137 and other radionuclides from the Sellafield (formerly Windscale) reprocessing plant...

  1. Environmental releases for calendar year 1993

    International Nuclear Information System (INIS)

    Thomas, S.P.; Curn, B.L.

    1994-07-01

    This report presents data on radioactive and nonradioactive materials released into the environment during calendar year 1993 from facilities managed by Westinghouse Hanford Company. As part of this executive summary, comprehensive data summaries of air emissions and liquid effluents in 1993 are displayed in tables. These tables represent the following: radionuclide air emissions data; data on radioactive liquid effluents discharged to the soil; radionuclides discharged to the Columbia River; nonradioactive air emissions data; total volumes and flow rates of 200/600 area liquid effluents. Both summary and detailed presentations of these data are given. When appropriate, comparisons to data from previous years are made

  2. Management of radioactive effluents from research Reactors and PHWRs

    International Nuclear Information System (INIS)

    Bodke, S.B.; Surender Kumar; Sinha, P.K.; Budhwar, R.K.; Raj, Kanwar

    2006-01-01

    Indian nuclear power programme is mainly based on pressurized heavy water reactors (PHWRs). In addition we have research reactors namely Apsara, CIRUS, Dhruva at Trombay. The operation and maintenance activities of these reactors generate radioactive liquid waste. These wastes require effective management so that the release of radioactivity to the environment is well within the authorized limits. India is self reliant in the design, erection, commissioning and operation of effluent management system for nuclear reactors. Segregation at source based on nature of effluents and radioactivity content is the first and foremost step in the over all management of liquid effluents. The effluents from the power reactors contain mainly activation products like 3 H. It also contains fission products like 137 Cs. Containment of these radionuclide along with 60 Co, 90 Sr, 131 I plays an important part in liquid waste management. Treatment processes for decontamination of these radionuclide include chemical treatment, ion exchange, evaporation etc. Effluents after treatment are monitored and discharged to the nearby water body after filtration and dilution. The concentrates from the processes are conditioned in cement matrix and disposed in Near Surface Disposal Facilities (NSDFs) co-located at each site. Some times large quantity of effluents with higher radioactivity concentration may get generated from the abnormal operation such as failure of heat exchangers. These effluents are handled on a campaign basis for which adequate storage capacity is provided. The treatment is given taking into consideration the required decontamination factor (DF), capacities of available treatment process, discharge limits and the availability of the dilution water. Similarly large quantities of effluents may get generated during fuel clad failure incident in reactors. In such situation, as in CIRUS large volume of effluent containing higher radioactivity are generated and are managed by delay

  3. Environmental releases for calendar year 1996

    International Nuclear Information System (INIS)

    Greager, E.M.

    1997-01-01

    This report presents data on radioactive and nonradioactive materials released into the environment during calendar year 1996 from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (formerly the Westinghouse Hanford Company) and Bechtel Hanford, Incorporated. Fluor Daniel Hanford, Incorporated provides effluent monitoring services for Bechtel Hanford, Incorporated, which includes release reporting. Both summary and detailed presentations of the environmental releases are provided. When appropriate, comparisons to data from previous years are made

  4. Environmental releases for calendar year 1996

    Energy Technology Data Exchange (ETDEWEB)

    Greager, E.M.

    1997-07-31

    This report presents data on radioactive and nonradioactive materials released into the environment during calendar year 1996 from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (formerly the Westinghouse Hanford Company) and Bechtel Hanford, Incorporated. Fluor Daniel Hanford, Incorporated provides effluent monitoring services for Bechtel Hanford, Incorporated, which includes release reporting. Both summary and detailed presentations of the environmental releases are provided. When appropriate, comparisons to data from previous years are made.

  5. The management plan of liquid effluent in Korean advanced light water reactor

    International Nuclear Information System (INIS)

    Kim, S. H.; Lim, H. S.; Jeong, D. W.; Jeong, D. Y.

    2001-01-01

    Non-radioactive liquid effluent in Korean Advanced Light Water Reactor is transferred and treated in centralized waste treatment facility after the radioactivity in effluent is checked within power block. The liquid effluent from centralized waste treatment facility will be discharged by way of discharge canal in order to be in the sufficient condition. As a result of investigating the radiation monitoring design in accordance with 20 provisions by Korean Regulatory Authority, each effluent radiation monitoring with 20 provisions by Korean Regulatory Authority, each effluent radiation monitoring design satisfies the regulatory guideline. In relation to sampling and analyses, most systems satisfy the regulatory guideline except for some effluents from turbine building. And, though sampling and analyses are performed after radioactivity is monitored at each system in turbine building, these exceptions in turbine building effluents are expected to cause no significant problems because radioactivity is monitored by direct or indirect methods prior to release from turbine building. Integrated monitoring on liquid effluent from the centralized waste water treatment facility is not necessary because radiation monitoring, sampling and analyses on each system within power block are performed, and operational effectiveness compared with cost according to adding the radiation monitoring equipment is too low. So, whether the radiation monitoring in this effluent is reflected on design or not is planned to be determined through discussion with regulatory authority

  6. Rework of process effluents from the fabrication of HTR fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lasberg, Ingo; Braehler, Georg [NUKEM Technologies GmbH (Germany); Boyes, David [Pebble Bed Modular Reactor (Pty) Ltd., Centurion (South Africa)

    2008-07-01

    HTR fuel facilities require the application of several liquid chemicals and accordingly they produce significant amounts of Uranium contaminated/potentially contaminated effluents. The main effluents are (amounts for a 3 t Uranium/a plant): aqueous solutions including tetrahydrofurfuryl alcohol THFA, ammonium hydroxide NH4OH, and ammonium nitrate NH4NO3 (180 m{sup 3}/a), isopropanol IPA/water mixtures (130 m{sup 3}/a); Non-Process Water NPW (300 m{sup 3}/a); methanol (7m{sup 3}/a); additionally off-gas streams, containing ammonia (9 t/a) have to be treated. In an industrial scale facility all such effluents/gases need to be processed for recycling, decontamination prior to release to the environment (as waste or as valuable material). Thermal decomposition is applied to dispose of burnable residues.

  7. Sistemas farmacêuticos gastrorretentivos flutuantes Pharmaceutical gastro-retentive systems

    Directory of Open Access Journals (Sweden)

    Pedro Miguel da Costa Barrocas

    2007-09-01

    Full Text Available Freqüentemente recorre-se à produção de sistemas gastrorretentivos para modular a liberação de fármacos a partir de sistemas farmacêuticos com vistas ao aumento do tempo de permanência do fármaco no trato gastrointestinal. Umas das estratégias mais interessantes passa pela produção de sistemas flutuantes. Estes podem ser classificados em dois grupos: sistemas flutuantes efervescentes e sistemas flutuantes não-efervecentes. Neste artigo apresenta-se uma revisão bibliográfica do que tem sido produzido nesta área nos últimos anos.Gastro-retentive systems are often produced in order to modulate drugs release from pharmaceutical forms and in this way to increase drug residence time in the gastrointestinal tract. One of the most interesting strategies consists in the preparation of floating devices. These can be classified into two groups: effervescent systems and non-effervescent systems. A review of what has been done in the last years is presented in this article.

  8. Behaviour of radioiodine in gaseous effluents

    International Nuclear Information System (INIS)

    Barry, P.J.

    1968-01-01

    Because of the different chemical forms in which radioiodine occurs in the gaseous state, it is important when designing efficient filters to know the chemical forms which may be present in the effluent gases when various operations are being carried out and to know the effect of different gaseous environments on the filtration efficiency. To obtain this information it is necessary to have available reliable means of characterizing different chemical forms and to sample gaseous effluents when these operations are being carried out. This paper describes the use for identifying molecular iodine of metallic screens in a multi-component sampling pack in different gaseous environments. Using multi-component sampling packs, the fractionation of iodine nuclides between different chemical forms was measured in the effluent gases escaping from an in-pile test loop in which the fuel was deliberately ruptured by restricting the flow of coolant. Sequential samples were taken for six hours after the rupture and it was possible to follow during this period the individual behaviours of 13 '1I, 133 I and 135 I. Simultaneous samples were also obtained of the noble gases in the effluent gas stream and of the iodine nuclides in the loop coolant. Similar experiments have been carried out with a view to characterizing the different chemical behaviour of radioiodine as it is released from a variety of operations in the nuclear industry including the cutting of fuel sections in metallurgical examination caves and an incinerator. (author)

  9. Wastewater treatment plant effluents as source of cosmetic polyethylene microbeads to freshwater.

    Science.gov (United States)

    Kalčíková, G; Alič, B; Skalar, T; Bundschuh, M; Gotvajn, A Žgajnar

    2017-12-01

    Microplastics in the environment are either a product of the fractionation of larger plastic items or a consequence of the release of microbeads, which are ingredients of cosmetics, through wastewater treatment plant (WWTP) effluents. The aim of this study was to estimate the amount of microbeads that may be released by the latter pathways to surface waters using Ljubljana, Slovenia as a case study. For this purpose, microbeads contained in cosmetics were in a first step characterized for their physical properties and particle size distribution. Subsequently, daily emission of microbeads from consumers to the sewerage system, their fate in biological WWTPs and finally their release into surface waters were estimated for Ljubljana. Most of the particles found in cosmetic products were sewerage system at an average rate of 15.2 mg per person per day. Experiments using a lab-scale sequencing batch biological WWTP confirmed that on average 52% of microbeads are captured in activated sludge. Particle size analyses of the influent and effluent confirmed that smaller particles (up to 60-70 μm) are captured within activated sludge while bigger particles were detected in the effluent. Applying these data to the situation in Ljubljana indicates that about 112,500,000 particles may daily be released into the receiving river, resulting in a microbeads concentration of 21 particles/m 3 . Since polyethylene particles cannot be degraded and thus likely accumulate, the data raise concerns about potential effects in aquatic ecosystems in future. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Performance of Azolla caroliniana Willd. and Salvinia auriculata Aubl. on fish farming effluent

    Directory of Open Access Journals (Sweden)

    JJ. Toledo

    Full Text Available The increasing release of untreated fish farming effluents into water courses that flow to the Pantanal wetlands in Mato Grosso (Brazil may drive this ecosystem to eutrophication. Therefore, the growth of Azolla caroliniana Willd. and Salvinia auriculata Aubl. in fish farming effluent and their effect on its quality were evaluated for 48 days in a greenhouse. The results were compared to those obtained in a nutrient rich solution (Hoagland ½ medium. Azolla caroliniana showed lower relative growth rate in fish farming effluent (0.020 d-1 than in Hoagland ½ medium (0.029 d-1. However, S. auriculata grew slightly better in fish farming effluent (0.030 d-1 than in Hoagland ½ medium (0.025 d-1. The species apparently contributed to reduce nitrate and phosphate concentration in Hoagland ½ medium. However, in fish farming effluent, only electrical conductivity and pH were reduced by plants compared to the control without plants. Thus, A. caroliniana and S. auriculata show low potential for improving effluent quality.

  11. Bio-decolourization of textile effluent containing Reactive Black-B by ...

    African Journals Online (AJOL)

    Release of coloured textile effluents is undesirable in the aquatic environment as they reduce light penetration, thereby affecting aquatic life and limits utilization of the water media. Microbial bioremediation is an alternative treatment option available other than the commonly employed physicochemical and biological ...

  12. A new stack effluent monitoring system at the Risoe Hot Cell plant

    International Nuclear Information System (INIS)

    Boetter-Jensen, L.; Hedemann Jensen, P.; Lauridsen, B.

    1984-06-01

    This report describes a new stack effluent monitoring system that has been installed at the Hot Cell facility. It is an integrating iodine/particulate system consisting of a γ-shielded flow house in which a continous air sample from the ventilation channel ia sucked through coal and glass filter papers. Activity is accumulated on the filter papers and a thin plastic scintillator detects the β-radiation from the trapped iodine or particulate activity. The stack effluent monitoring system has a two-step regulating function as applied to the ventilation system, first switching it to a recirculating mode, and finally to building-seal after given releases of 131 I. The collection efficiency for iodine in form of elementary iodine (I 2 ) and methyliodide (CH 3 I) has been determined experimentally. The unwanted response from a noble gas release has also been determined from experiments. The noble gas response was determined from puff releases of the nuclide 41 Ar in the concrete cells. It is concluded that the iodine/particulate system is extremely sensitive and that it can easily detect iodine or particulate releases as low as a few MBq. A gamma monitor placed in connection with the iodine/particulate system detects Xe/Kr-releases as low as a few tens of MBq per second. (author)

  13. Decision no 2009-DC-0157 of the 15. of September 2009 by the Nuclear Safety Authority specifying the limits of releases in the environment of liquid and gaseous effluents of the base nuclear installation n. 29 operated by the CIS Bio International on the district of Saclay (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of a base nuclear installation. Tables present the limits for radioactive liquid effluents (iodine, rare earths, and other beta and gamma emitters) and the maximum admitted concentrations for gaseous chemical effluents (SO 2 , H 2 S, VOCs)

  14. Sistema de tratamento de efluentes para o campus da Universidade Federal de Campina Grande na cidade de Pombal

    Directory of Open Access Journals (Sweden)

    Graziela Pinto de Freitas

    2016-04-01

    Full Text Available Com a crescente demanda populacional da cidade universitária, aumentam-se os despejos de efluentes líquidos nos corpos hídricos fazendo-se necessário um tratamento eficaz, a fim de remover a carga orgânica poluidora antes de serem descartados. Nesse trabalho, objetivou-se apresentar um sistema de tratamento de efluentes para Universidade Federal de Campina Grande, Campus de Pombal localizado no estado da Paraíba. No desenvolvimento do estudo foram realizadas as seguintes etapas: caracterização detalhada do campus Pombal/UFCG, situação atual do esgotamento sanitário dentro do Campus de Pombal, diagnóstico dos possíveis impactos ambientais decorrentes do atual sistema de tratamento de esgoto, medidas mitigadoras e por fim apresentado um sistema de tratamento que melhor se adeque as condições do local em estudo. Na metodologia foram necessárias visitas in loco, entrevistas informais a estudantes e funcionários, fotodocumentação do local de estudo e pesquisas bibliográficas. A partir dos resultados observou-se que o sistema de tratamento utilizado no campus apresenta falhas, sendo necessária a substituição de tal procedimento de tratamento. O sistema proposto foi por meio do processo anaeróbio com reator UASB seguido por Lodo Ativado Convencional, com escolha a partir do fato de ser um sistema compacto, não necessitando de grandes áreas para implantação, assim como também um sistema de baixo custo operacional e apresentar baixo tempo de detenção hidráulico.Effluent Treatment System for campus of the Federal University of Campina Grande in Pombal Cit Abstract: With the growing population demand of the university town, the liquid effluent discharges are increased in water bodies making it necessary effective treatment, to remove the polluting organic load before being discarded. In this study aimed to present an effluent treatment system to Federal University of Campina Grande, Campus de Pombal located in the state of

  15. Impact simulation of shrimp farm effluent on BOD-DO in Setiu River

    Science.gov (United States)

    Chong, Michael Sueng Lock; Teh, Su Yean; Koh, Hock Lye

    2017-08-01

    Release of effluent from intensive aquaculture farms into a river can pollute the receiving river and exert negative impacts on the aquatic ecosystem. In this paper, we simulate the effects of effluent released from a marine shrimp aquaculture farm into Sg Setiu, focusing on two critical water quality parameters i.e. DO (dissolved oxygen) and BOD (biochemical oxygen demand). DO is an important constituent in a river in sustaining water quality, with levels of DO below 5 mg/L deemed undesirable. DO levels can be depressed by the presence of BOD and other organics that consume DO. Water quality simulations in conjunction with management of effluent treatment can suggest mitigation measures for reducing the adverse environmental impact. For this purpose, an in-house two-dimensional water quality simulation model codenamed TUNA-WQ will be used for these simulations. TUNA-WQ has been undergoing regular updates and improvements to broaden the applicability and to improve the robustness. Here, the model is calibrated and verified for simulation of DO and BOD dynamics in Setiu River (Sg Setiu). TUNA-WQ simulated DO and BOD in Setiu River due to the discharge from a marine shrimp aquaculture farm will be presented.

  16. The exposure of the EC (European Community) population from nuclear industry effluents

    International Nuclear Information System (INIS)

    Broomfield, M.

    1983-01-01

    The collective dose commitment to the EC population from routine effluents released from nuclear power stations and reprocessing plants within the Community in 1978 amounted to approximately 500 man Sv. The collective dose commitments associated with discharges from the nuclear power stations was approximately 50 man Sv, being almost entirely due to airborne carbon-14. The total collective dose commitment from the reprocessing plants was approximately 450 man Sv, about two-thirds of which was due to radiocaesium in the liquid effluent from Sellafield. (UK)

  17. Estimation of inhalation doses from airborne releases using gross monitors

    International Nuclear Information System (INIS)

    Goldstein, N.P.

    1978-01-01

    Monitoring programs at most nuclear facilities involve continuous gross measurements supplemented by periodic isotopic analyses of release samples. The isotopic measurements are required to accurately assess the potential dose from the various effluent streams, but in between these measurements, one depends on the gross monitors to provide approximate indications of the dose. The effluent streams release a variety of nuclides, each with its own dose factor. This means that the relationship between the counting rate in a gross monitor and the potential dose of the effluent being monitored will depend on the isotopic composition of this release. If this composition changes, then the dose indicated by the gross monitor (calibrated for the original group of isotopes) may be significantly in error. The problem of indicating inhalation doses from gross monitoring of airborne releases is considered. In order for this type of monitor to accurately indicate dose, regardless of the isotopic makeup of a release, the analysis shows that its response to each isotope should be proportional to the dose factor of that isotope. These ideas are applied to the monitoring of air particulates using gross beta and gross gamma monitors. The study shows that the former more closely satisfies this condition and as a result, satisfactorily indicates the actual dose from reactor effluents, as determined from detailed isotopic data published in the literature. On the other hand, the gross gamma monitor, with its poorer fit to the condition, provided less than satisfactory accuracy in its dose estimates. In addition, a variety of other mathematical response functions were considered but their dose estimation capabilities were not much better than the straight beta response. The study shows that reasonably accurate dose estimates can be made using properly selected gross monitors, but that significant errors can result with improper ones. (author)

  18. Sampling and monitoring of carbon-14 in gaseous effluents from nuclear facilities - a literature survey

    International Nuclear Information System (INIS)

    Snellman, M.

    1988-12-01

    C-14 compounds produced in the coolant may be released mainly together with off-gas and waste water from the coolant purification and treatment system. In reactors the release of C-14 will occur mainly in gaseous effluents and only a few percent in liquid effluents. Reported releases from BWRs range from 260 to 670 GBq/GW(e) x year and from 90 to 430 GBq/GW(e) x year for PWRs. At BWRs the condenser air ejector contributes the main inplant release pathway, whereas in PWRs the off-gas treatment vents are the main pathway for C-14 release. C-14 sampling methods depend generally on the C-14 being in the form of CO 2 . The off-gas discharges from BWRs are mainly in the form of CO 2 whereas in PWRs a major fraction of the released C-14 is in the form of hydrocarbons or carbon monoxide (generally 80-100%). Sampling systems in PWRs should therefore be equipped with a catalytic oxidizer to convert all C-14 to CO 2 before trapping. The purpose of this study is to provide information on the techniques available for sampling and monitoring C-14

  19. Atomics International environmental monitoring and facility effluent annual report, 1976

    International Nuclear Information System (INIS)

    Moore, J.D.

    1977-01-01

    Environmental and facility effluent radioactivity monitoring at Atomics International (AI) is performend by the Radiation and Nuclear Safety Unit of the Health, Safety, and Radiation Services Department. Soil, vegetation, and surface water are routinely sampled to a distance of 10 miles from AI sites. Continuous ambient air sampling and thermoluminescent dosimetry are performed on site for monitoring airborne radioactivity and site ambient radiation levels. Radioactivity in effluents discharged to the atmosphere from AI facilities is continuously sampled and monitored to ensure that levels released to unrestricted areas are within appropriate limits, and to identify processes which may require additional engineering safeguards to minimize radioactivity levels in such effluents. In addition, selected nonradioactive constituents in surface water discharged to unrestricted areas are determined. This report summarizes and discusses monitoring results for 1976. The results of a special soil plutonium survey performed during the year are also summarized

  20. Controlled decomposition and oxidation: A treatment method for gaseous process effluents

    Science.gov (United States)

    Mckinley, Roger J. B., Sr.

    1990-01-01

    The safe disposal of effluent gases produced by the electronics industry deserves special attention. Due to the hazardous nature of many of the materials used, it is essential to control and treat the reactants and reactant by-products as they are exhausted from the process tool and prior to their release into the manufacturing facility's exhaust system and the atmosphere. Controlled decomposition and oxidation (CDO) is one method of treating effluent gases from thin film deposition processes. CDO equipment applications, field experience, and results of the use of CDO equipment and technological advances gained from the field experiences are discussed.

  1. ANDOSE: a computer code for calculating annual doses to man from routine releases of LWR effluents for the purpose of evaluating compliance with JAEC's guide for doseobjectives

    International Nuclear Information System (INIS)

    Iijima, Toshinori; Shiraishi, Tadao

    1979-10-01

    For environmental doses from routine releases of LWRs effluents to meet the Criterion 'As Low As is Practicable (ALAP)', Japan Atomic Energy Commission (JAEC) established a series of guides, the first for 'Dose Objectives' (May 1975), the second for models and parameters for calculating the environmental doses to compare with the 'Dose Objectives' (September 1976), and the third providing onsite meteorological programs, statistics of the data obtained and atmospheric dispersion models (June 1977). JAERI has developed a computer code, designated as ANDOSE, for calculating annual releases of radioactive gaseous and liquid effluents and, then, total body doses and thyroid doses to individuals around sites on the basis of these guides. The total body doses are from radioactive noble gases as well as from radioactive materials taken with marine food. For the calculation of thyroid doses are taken into account exposure pathways via inhalation and ingestion of leafy vegetables, cow's milk and marine food. The age-specific thyroid doses are evaluated. The doses are summed up when multisource or multisite conditions need to be evaluated (Nuclear Safety Bureau's requirement). In the present report, are described source-term models, environmental transport models and dose models used in the code, of which most are provided in the guides but some are complemented by the authors, the functions of ANDOSE and the manual for users of the code. The program lists and the latter two guides mentioned above are included in the appendices. (author)

  2. 10 CFR 61.41 - Protection of the general population from releases of radioactivity.

    Science.gov (United States)

    2010-01-01

    ... radioactivity. 61.41 Section 61.41 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR... from releases of radioactivity. Concentrations of radioactive material which may be released to the... maintain releases of radioactivity in effluents to the general environment as low as is reasonably...

  3. Order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche

    International Nuclear Information System (INIS)

    2003-01-01

    This document, took out from the Official Journal, is the law text relative to the order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche. (A.L.B.)

  4. Radioactive materials released from nuclear power plants (1976)

    International Nuclear Information System (INIS)

    Decker, T.R.

    1978-11-01

    Releases of radioactive materials in airborne and liquid effluents from commercial light water reactors during 1976 have been compiled and reported. Data on solid waste shipments as well as selected operating information have been included. This report supplements earlier annual reports issued by the former Atomic Energy Commission and the Nuclear Regulatory Commission. The 1976 release data are compared with previous year releases in tabular form. Data covering specific radionuclides are summarized

  5. Impact of treated effluents released from processing of radioactive mineral on the aquatic environment of Periyar river

    International Nuclear Information System (INIS)

    Radhakrishnan, Sujata; Haridasan, P.P.; Radhakrishna Pillai, K.; Pillai, P.M.B.; Khan, A.H.

    2005-01-01

    The chemical processing of monazite/ thorium concentrate for the separation of thorium, uranium and rare earths results in the generation of effluents, both acidic and alkaline. Indian Rare Earths Ltd (IREL), Udyogamandal was carrying out processing of monazite for nearly 50 years. Presently (since 2004) Indian Rare Earths Ltd, Udyogamandal is processing earlier stocked thorium hydroxide concentrate retrieved from Silos to produce Thorium Oxalate (along with a small percentage of Rare Earth elements), Nuclear Grade Ammonium Di-Uranate (NGADU), and small quantities of Nuclear Grade Thorium Oxide ('THRUST' Project). The treated effluents after monitoring are discharged to river Periyar. River Periyar is the recipient water body for treated effluents from IREL as well as a host of other chemical industries. Indian Rare Earths Ltd, Udyogamandal had been carrying out chemical processing of monazite for the past 50 years. Recently, from 2004, the plant has shifted from monazite processing to processing of thorium concentrate (THRUST Project). The present paper discusses the characteristics of the effluents generated as per this project, their treatment, monitoring methodology, discharge and impact on the aquatic environment of river Periyar. It has been noted that the impact on the aquatic environment by way of enhancing the natural background radioactivity in the river had been insignificant. (author)

  6. Technologies for the treatment of effluents from uranium mines, mills and tailings. Proceedings of a technical committee meeting

    International Nuclear Information System (INIS)

    2002-06-01

    Effluent treatment is an important aspect of uranium mining and milling operations that continues through decommissioning and site rehabilitation. During the life of a mine, effluent treatment is an integral part of the operation with all effluent either being recycled to the mill or processed through a water treatment plant before being released into the environment. During decommissioning and rehabilitation, effluent treatment must continue either through a water treatment plant of by using passive treatment techniques. Because of the recent closing of several uranium mines or mining districts, particularly in eastern Europe, effluent treatment is becoming an ever increasing concern. Therefore the IAEA convened a technical committee meeting (TCM) so that experts from different countries could discuss information and knowledge on effluent treatment processes and methods. The papers presented at the meeting describe techniques for treatment of effluents from uranium production operations - both past and present. This publication contains ten papers presented at the meeting; each of the papers was indexed separately

  7. Radiological impact of airborne effluents of coal-fired and nuclear power plants

    International Nuclear Information System (INIS)

    McBride, J.P.; Moore, R.E.; Witherspoon, J.P.; Blanco, R.E.

    1977-06-01

    Radiological impact of naturally occurring radionuclides in airborne effluents of a model coal-fired steam plant is evaluated assuming a release to the atmosphere of 1 percent of the ash in the coal burned and compared with the impact of radioactive materials in the airborne effluents of model light-water reactors. The principal exposure pathway for radioactive materials released from both types of plants is ingestion of contaminated foodstuffs. For nuclear plants immersion in the airborne effluents is also a significant factor in the dose commitment. Assuming that the coal burned contains 1 ppM uranium and 2 ppM thorium together with their decay products and using the same impact analysis methods used in evaluating nuclear facilities, the maximum individual dose commitments from the coal plant for the whole body and most organs (except the thyroid) are shown to be greater than those from a pressurized-water reactor (PWR) and, with the exception of the bone and kidney doses, less than those from a boiling-water reactor (BWR). With the exception of the bone dose, the maximum individual dose commitments from the coal plant are less than the numerical design guideline limits listed for light-water reactors (LWRs). Population dose commitments from the coal plant are higher than those from either nuclear plant

  8. Tetracycline resistance in semi-arid agricultural soils under long-term swine effluent application.

    Science.gov (United States)

    Popova, Inna E; Josue, Rosemarie D R; Deng, Shiping; Hattey, Jeffory A

    2017-05-04

    Annually, millions pounds of antibiotics are released unmetabolized into environment along with animal wastes. Accumulation of antibiotics in soils could potentially induce the persistence of antibiotic resistant bacteria. Antibiotics such as tetracyclines and tetracycline-resistant bacteria have been previously detected in fields fertilized with animal manure. However, little is known about the accumulation of tetracyclines and the development of tetracycline resistance in semi-arid soils. Here we demonstrate that continuous land application with swine effluent, containing trace amounts of chlortetracycline, does not necessarily induce tetracycline resistance in soil bacteria. Based on the testing of more than 3,000 bacteria isolated from the amended soils, we found no significant increase in the occurrence and level of chlortetracycline resistant bacteria in soils after 15 years of continuous swine effluent fertilization. To account for a possible transfer of tetracycline-resistant bacteria originated from the swine effluent to soils, we analyzed two commonly found tetracycline resistant genes, tet(O) and tet(M), in the swine effluent and fertilized soils. Both genes were present in the swine effluent, however, they were not detectable in soils applied with swine effluent. Our data demonstrate that agronomic application of manure from antibiotic treated swine effluent does not necessarily result in the development of antibiotic bacterial resistance in soils. Apparently, concentrations of chlortetracycline present in manure are not significant enough to induce the development of antibiotic bacterial resistance.

  9. Environmental assessment for effluent reduction, Los Alamos National Laboratory, Los Alamos, New Mexico

    International Nuclear Information System (INIS)

    1996-01-01

    The Department of Energy (DOE) proposes to eliminate industrial effluent from 27 outfalls at Los Alamos National Laboratory (LANL). The Proposed Action includes both simple and extensive plumbing modifications, which would result in the elimination of industrial effluent being released to the environment through 27 outfalls. The industrial effluent currently going to about half of the 27 outfalls under consideration would be rerouted to LANL's sanitary sewer system. Industrial effluent from other outfalls would be eliminated by replacing once-through cooling water systems with recirculation systems, or, in a few instances, operational changes would result in no generation of industrial effluent. After the industrial effluents have been discontinued, the affected outfalls would be removed from the NPDES Permit. The pipes from the source building or structure to the discharge point for the outfalls may be plugged, or excavated and removed. Other outfalls would remain intact and would continue to discharge stormwater. The No Action alternative, which would maintain the status quo for LANL's outfalls, was also analyzed. An alternative in which industrial effluent would be treated at the source facilities was considered but dismissed from further analysis because it would not reasonably meet the DOE's purpose for action, and its potential environmental effects were bounded by the analysis of the Proposed Action and the No Action alternatives

  10. Experiences of simulated tracer dispersal studies using effluent discharges at Tarapur aquatic environment

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Sawane, Pratibha; Rao, D.D.; Hegde, A.G.

    2007-01-01

    The nuclear complex in Tarapur, Maharashtra is a multi facility nuclear site comprising of power reactors and research facilities. Each facility has independent liquid effluent discharge line to Arabian Sea. Experimental studies were conducted to evaluate dilution factors in the aquatic environment using liquid effluent releases as tracer from one of the facilities. 3 H and 137 Cs radioisotopes present in the routine releases were used as simulated tracer nuclides. The dilution factors(D.F) observed for tritium were in the range of 20-20000 in a distance range of 10 m to 1500 m respectively and for 137 Cs the D.F. were in the range of 50 to 900 over a distance range of 10-200 m. The paper describes the analytical methodology and sampling scenarios and the results of dilution factors obtained for Tarapur aquatic environment. (author)

  11. Effluent standards

    Energy Technology Data Exchange (ETDEWEB)

    Geisler, G C [Pennsylvania State University (United States)

    1974-07-01

    At the conference there was a considerable interest in research reactor standards and effluent standards in particular. On the program, this is demonstrated by the panel discussion on effluents, the paper on argon 41 measured by Sims, and the summary paper by Ringle, et al. on the activities of ANS research reactor standards committee (ANS-15). As a result, a meeting was organized to discuss the proposed ANS standard on research reactor effluents (15.9). This was held on Tuesday evening, was attended by members of the ANS-15 committee who were present at the conference, participants in the panel discussion on the subject, and others interested. Out of this meeting came a number of excellent suggestions for changes which will increase the utility of the standard, and a strong recommendation that the effluent standard (15.9) be combined with the effluent monitoring standard. It is expected that these suggestions and recommendations will be incorporated and a revised draft issued for comment early this summer. (author)

  12. Offsite dose calculation manual guidance: Standard radiological effluent controls for pressurized water reactors

    International Nuclear Information System (INIS)

    Meinke, W.W.; Essig, T.H.

    1991-04-01

    This report contains guidance which may be voluntarily used by licensees who choose to implement the provision of Generic Letter 89-01, which allows Radiological Effect Technical Specifications (RETS) to be removed from the main body of the Technical Specifications and placed in the Offsite Dose Calculation Manual (ODCM). Guidance is provided for Standard Effluent Controls definitions, Controls for effluent monitoring instrumentation, Controls for effluent releases, Controls for radiological environmental monitoring, and the basis for Controls. Guidance on the formulation of RETS has been available in draft from (NUREG-0471 and -0473) for a number of years; the current effort simply recasts those RETS into Standard Radiological Effluent Controls for application to the ODCM. Also included for completeness are: (1) radiological environmental monitoring program guidance previously which had been available as a Branch Technical Position (Rev. 1, November 1979); (2) existing ODCM guidance; and (3) a reproduction of generic Letter 89-01

  13. Operational experience of gaseous effluent treatment at the Eurochemic reprocessing plant

    International Nuclear Information System (INIS)

    Osipenco, A.; Detilleux, E.

    1977-01-01

    The EUROCHEMIC fuel reprocessing plant applies the PUREX flow sheet. Two particular features of the plant influence gaseous and liquid effluents: chemical decanning and the ability to process a wide range of fuels, uranium metal or oxide, having an initial enrichment typical of power reactors (up to 5%) or material testing reactors (up to 93%). The ventilation circuits, treatment plant and monitoring equipment for gaseous releases are briefly described. No retention facilities for rare gases, tritium, or carbon-14 are provided. The releases are monitored for krypton-85, iodine-131, alpha and beta-gamma aerosols and tritium. Between 1966 and 1974 the plant processes about 200 tonnes of power reactor fuel, from which about 0.7 tonnes of plutonium and 1.5 tonnes of highly enriched uranium were separated. The most important points in the operation of the gas cleaning equipment are indicated: efficiency, operational reliability, incidents, etc.. Actual discharges as measured are compared with the limits set in the operation licence. Using the atmospheric diffusion coefficients, the dose commitment is estimated. The low level liquid effluents are passed, after neutralization, to the treatment plant of the Belgian nuclear center CEN/SCK. However, if the activity exceeds the limit set by the CEN/SCK, the effluents are concentrated by evaporation and stored on the EUROCHEMIC site. (orig.) [de

  14. Environmental and effluent monitoring at ANSTO sites, 2004-2005

    International Nuclear Information System (INIS)

    Hoffmann, Emmy L.; Loosz, Tom; Ferris, John M.; Harrison, Jennifer J.

    2005-01-01

    This report presents the results of ANSTO's environmental and effluent monitoring at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC) sites, from July 2004 to June 2005. Effective doses to the critical group of members of the public potentially affected by routine airborne emissions from the LHSTC were less than 0.005 mSv/year. This estimated maximum potential dose is less than 24% of the ANSTO ALARA objective of 0.02 mSv/year, and much lower than the public dose limit of 1 mSv/year that is recommended by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). The effective doses to the critical group of members of the public potentially exposed to routine liquid effluent releases from the LHSTC have been realistically estimated as a quarter (or less) of the estimated doses to the critical group for airborne releases. The levels of tritium detected in groundwater and stormwater at the LHSTC were less than those set out in the Australian Drinking Water Guidelines. The airborne and liquid effluent emissions from the NMC were below both the ARPANSA-approved notification levels and Sydney Water limits for acceptance of trade wastewater to sewer. Results of environmental monitoring at both ANSTO sites confirm that the facilities continue to be operated well within regulatory limits. ANSTO's routine operations at the LHSTC and NMC make only a very small addition to the natural background radiation dose of ∼1.5 mSv/year experienced by members of the Australian public

  15. Radioactive materials released from nuclear power plants

    International Nuclear Information System (INIS)

    Tichler, J.; Norden, K.; Congemi, J.

    1991-05-01

    Releases of radioactive materials in airborne and liquid effluents from commercial light water reactors during 1988 have been compiled and reported. Data on solid waste shipments as well as selected operating information have been included. This report supplements earlier annual reports issued by the former Atomic Energy Commission and the Nuclear Regulatory Commission. The 1988 release data are summarized in tabular form. Data covering specific radionuclides are summarized. 16 tabs

  16. Facility effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the facility effluent monitoring programs and provides an evaluation of effluent monitoring data. These evaluations are useful in assessing the effectiveness of effluent treatment and control systems, as well as management practices.

  17. A study of effluent control technologies employed by radiopharmaceutical users and suppliers

    International Nuclear Information System (INIS)

    Leventhal, L.; Slider, J.; Chakoff, E.; Cehn, J.I.; Savage, E.

    1980-01-01

    The radiopharmaceutical industry facilities in the U.S.A. have been reviewed to identify factors that could lead to the airborne release of radioactive isotopes, and to assess the control technology employed. The subject is dealt with in brief outline under the following headings: 1) Hospital usage, the radionuclides being grouped according to use. The main potential airborne effluents were 131 I, 133 Xe, and sup(99m)Tc. 2) Monitoring of facilities for airborne effluents. 3) Control technology, either by dilution or by storage to reduce radioactivity; suppliers and users effluent controls. It was found that the control equipment is readily available, reliable, and effective. Cost appears to increase proportionately with the dose reduction provided. NRC requirements and cost-benefit ratios determine choice. It was concluded that current practices in the industry are adequate. (U.K.)

  18. Polishing of anaerobic secondary effluent by Chlorella vulgaris under low light intensity

    KAUST Repository

    Cheng, Tuoyuan; Wei, Chunhai; Leiknes, TorOve

    2017-01-01

    To investigate anaerobic secondary effluent polishing by microalgae (Chlorella vulgaris) under low light intensity (14 μmol/m2/s), bubbling column reactors were operated in batches of 8 d with initial ammonium nitrogen 10-50 mg/L, initial phosphate phosphorus 2-10 mg/L and microalgal seed 40 mg/L. Maximum microalgal biomass and minimum generation time were 370.9 mg/L and 2.5 d, respectively. Nitrogen removal (maximum 99.6%) was mainly attributed to microalgal growth rate, while phosphorus removal (maximum 49.8%) was related to microalgal growth rate, cell phosphorus content (maximum 1.5%) and initial nutrients ratio. Dissolved microalgal organics release in terms of chemical oxygen demand (maximum 63.2 mg/L) and hexane extractable material (i.e., oil and grease, maximum 8.5 mg/L) was firstly reported and mainly affected by nitrogen deficiency and deteriorated effluent quality. Ultrafiltration critical flux (16.6-39.5 L/m2/h) showed negative linear correlation to microalgal biomass. Anaerobic membrane bioreactor effluent polishing showed similar results with slight inhibition to synthetic effluent.

  19. Polishing of anaerobic secondary effluent by Chlorella vulgaris under low light intensity

    KAUST Repository

    Cheng, Tuoyuan

    2017-05-29

    To investigate anaerobic secondary effluent polishing by microalgae (Chlorella vulgaris) under low light intensity (14 μmol/m2/s), bubbling column reactors were operated in batches of 8 d with initial ammonium nitrogen 10-50 mg/L, initial phosphate phosphorus 2-10 mg/L and microalgal seed 40 mg/L. Maximum microalgal biomass and minimum generation time were 370.9 mg/L and 2.5 d, respectively. Nitrogen removal (maximum 99.6%) was mainly attributed to microalgal growth rate, while phosphorus removal (maximum 49.8%) was related to microalgal growth rate, cell phosphorus content (maximum 1.5%) and initial nutrients ratio. Dissolved microalgal organics release in terms of chemical oxygen demand (maximum 63.2 mg/L) and hexane extractable material (i.e., oil and grease, maximum 8.5 mg/L) was firstly reported and mainly affected by nitrogen deficiency and deteriorated effluent quality. Ultrafiltration critical flux (16.6-39.5 L/m2/h) showed negative linear correlation to microalgal biomass. Anaerobic membrane bioreactor effluent polishing showed similar results with slight inhibition to synthetic effluent.

  20. Evaluation 2000 and regulation and method. Release monitoring and environmental surveillance around Cea centers

    International Nuclear Information System (INIS)

    2001-06-01

    This publication counts for the year 2000 for the evaluation of liquid and gaseous radioactive effluents releases and the radioactivity levels measured in the vicinity of Cea centers, through the air, water, vegetation and milk surveillance. An analysis of the results from 1996 to 2000 allows to follow their evolution. A second booklet develops the sampling and measurement methods made on effluents in environment. It present besides the regulation applied to effluents monitoring. (N.C.)

  1. Limited Releases of Krsko NPP

    International Nuclear Information System (INIS)

    Breznik, B.; Kovac, A.

    2001-01-01

    Full text: Krsko Nuclear Power Plant is about 700 MW Pressurised Water Reactor plant located in Slovenia close to the border with Croatia. The authorised limit for the radioactive releases is basically set to 50 μSv effective dose per year to the members of the public. There is also additional limitation of total activities released in a year and concentration. The poster presents the effluents of the year 2000 and evaluated dose referring to the limits and to the natural and other sources of radiation around the plant. (author)

  2. Multi-year prediction of estrogenicity in municipal wastewater effluents.

    Science.gov (United States)

    Arlos, Maricor J; Parker, Wayne J; Bicudo, José R; Law, Pam; Marjan, Patricija; Andrews, Susan A; Servos, Mark R

    2018-01-01

    In this study, the estrogenicity of two major wastewater treatment plant (WWTP) effluents located in the central reaches of the Grand River watershed in southern Ontario was estimated using population demographics, excretion rates, and treatment plant-specific removals. Due to the lack of data on estrogen concentrations from direct measurements at WWTPs, the treatment efficiencies through the plants were estimated using the information obtained from an effects-directed analysis. The results show that this approach could effectively estimate the estrogenicity of WWTP effluents, both before and after major infrastructure upgrades were made at the Kitchener WWTP. The model was then applied to several possible future scenarios including population growth and river low flow conditions. The scenario analyses showed that post-upgrade operation of the Kitchener WWTP will not release highly estrogenic effluent under the 2041 projected population increase (36%) or summer low flows. Similarly, the Waterloo WWTP treatment operation is also expected to improve once the upgrades have been fully implemented and is expected to effectively treat estrogens even under extreme scenarios of population growth and river flows. The developed model may be employed to support decision making on wastewater management strategies designed for environmental protection, especially on reducing the endocrine effects in fish exposed to WWTP effluents. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Bioremediation of an iron-rich mine effluent by Lemna minor.

    Science.gov (United States)

    Teixeira, S; Vieira, M N; Espinha Marques, J; Pereira, R

    2014-01-01

    Contamination of water resources by mine effluents is a serious environmental problem. In a old coal mine, in the north of Portugal (São Pedro da Cova, Gondoma),forty years after the activity has ended, a neutral mine drainage, rich in iron (FE) it stills being produced and it is continuously released in local streams (Ribeiro de Murta e Rio Ferreira) and in surrounding lands. The species Lemna minor has been shown to be a good model for ecotoxicological studies and it also has the capacity to bioaccumulate metals. The work aimed test the potential of the species L. minor to remediate this mine effluent, through the bioaccumulation of Fe, under greenhouse experiments and, at the same time, evaluate the time required to the maximum removal of Fe. The results have shown that L. minor was able to grow and develop in the Fe-rich effluent and bioaccumulating this element. Throughout the 21 days of testing it was found that there was a meaningful increase in the biomass of L. minor both in the contaminated and in the non-contaminated waters. It was also found that bioaccumulation of Fe (iron) occurred mainly during the first 7 days of testing. It was found that L. minor has potential for the bioremediation of effluents rich in iron.

  4. Airborne effluent control at uranium mills

    International Nuclear Information System (INIS)

    Sears, M.B.

    1976-01-01

    The Oak Ridge National Laboratory has made an engineering cost--environmental benefit study of radioactive waste treatment systems for decreasing the amount of radioactive materials released from uranium ore processing mills. This paper summarizes the results of the study which pertain to the control and/or abatement of airborne radioactive materials from the mill processes. The tailings area is not included. Present practices in the uranium milling industry, with particular emphasis on effluent control and waste management, have been surveyed. A questionnaire was distributed to each active mill in the United States. Replies were received from about 75 percent of the mill operators. Visits were made to six operating uranium mills that were selected because they represented the different processes in use today and the newest, most modern in mill designs. Discussions were held with members of the Region IV Office of NRC and the Grand Junction Office of ERDA. Nuclear Science Abstracts, as well as other sources, were searched for literature pertinent to uranium mill processes, effluent control, and waste management

  5. Atmospheric release advisory capability

    International Nuclear Information System (INIS)

    Sullivan, T.J.

    1981-01-01

    The ARAC system (Atmospheric Release Advisory Capability) is described. The system is a collection of people, computers, computer models, topographic data and meteorological input data that together permits a calculation of, in a quasi-predictive sense, where effluent from an accident will migrate through the atmosphere, where it will be deposited on the ground, and what instantaneous and integrated dose an exposed individual would receive

  6. Research on the removal of radium from uranium effluent by air-aeration hydrated manganese hydroxide adsorption

    International Nuclear Information System (INIS)

    Zhang Jianguo; Chen Shaoqing; Qi Jing

    2002-01-01

    In the acidic leaching uranium process, pyrolusite or manganese oxide (MnO 2 ) powder is often used as an oxidizer. In the processed effluent, manganese ion present as a contaminant in addition to U, Ra, Th, As, Zn, Cu, F, SO 4 2- , etc. Manganese ion content is about 100∼200 mg/1 in effluent. In this case, a new process technique can be developed to treat the effluent using the Mn 2+ present in the effluent. The approach is as follows: The effluent is neutralized by lime milk to pH about 11. As a result, most contaminants are precipitated to meet the uranium effluent discharge standards (U, Th, Mn, SO 4 2- etc.), but radium is still present in the effluent. In this process, manganese ion forms manganese hydroxide Mn(OH) 2 . The manganese hydroxide is easily to oxide to form MnO(OH) 2 by air aeration. This hydrated manganese hydroxide complex can then be used to adsorb radium in effluent. The experiments show: (1) Effluent pH, manganese concentration in effluent, and aeration strength and time etc. influence the radium removal efficiency. Under the test conditions, when manganese in effluent is between 100∼300 mg/l, and pH is over 10.5, radium can be reduced to lower 1.11 Bq/1 in the processed effluent. Higher contents of impurity elements such as aluminum, silicon and magnesium in the effluent affect the removal efficiency; (2) Under the experimental conditions, the lime precipitation air-aeration formed hydrated manganese hydroxide complex sludge is stable. There is no obvious release of radium from the adsorbed hydrated manganese hydroxide complex sludge; (3) The current experiments show that hydrated manganese hydroxide complex sludge has a very good re-adsorption ability for removal of radium from uranium effluent. Some experimental parameters have been measured. (author)

  7. Desempenho de sistema de tratamento de lixiviado de aterro sanitário com recirculação do efluente Performance of a sanitary landfill leachate treatment system with effluent recirculation

    Directory of Open Access Journals (Sweden)

    Cláudia Lavina Martins

    2010-12-01

    Full Text Available O objetivo deste estudo foi avaliar o desempenho de um sistema de tratamento de lixiviado de aterro sanitário, em escala piloto, formado por três lagoas em série (L1, L2 e L3 seguidas por um filtro de pedras (FP. Foram estudadas três condições operacionais, verificando-se o efeito da recirculação do efluente da L3 para a L1: 0, 50 e 100% da vazão. O sistema absorveu bem as flutuações de cargas, apresentando remoções superiores a 80% para DBO F, 70% para DQO T e 98% para nitrogênio amoniacal. Na lagoa L2 houve nitrificação parcial, com acúmulo de nitritos. Ocorreu presença marcante do gênero Chlamydomonas nas lagoas L2 e L3 fotossintéticas. Observou-se diminuição da toxicidade do lixiviado, com reduções superiores a 95% na saída do sistema. A melhor eficiência de remoção para as três condições operacionais estudadas foi obtida com 100% de recirculação.The objective of this study was to evaluate the performance of a landfill leachate treatment system, at pilot scale, formed by three in series ponds (L1, L2, and L3 followed by a rock filter. Three operational conditions were studied, assessing the effluent recirculation effect from L3 to L1: 0, 50 and 100% of the flow rate. The system assimilated well the load fluctuations, showing removal efficiencies over 80% for BOD F, 70% for COD T and 98% for ammonia. In the L2 pond there was partial nitrification with nitrite accumulation. It was observed an outstanding presence of the Chlamydomonas gender in photosynthetic ponds L2 and L3. A reduction of the toxicity from the landfill leachate was observed, with reduction of over 95% in the system output. The better removal efficiency for the three studied operational conditions was obtained for 100% of recirculation.

  8. Releases of radioactivity at the Savannah River Plant, 1954--1985

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Lawrimore, I.B.

    1988-07-01

    Radioactive releases from Savannah River Plant (SRP) facilities to air, water and earthen seepage basins have been monitored and tabulated throughout the history of the site. The purpose of this report is to provide a source of data on routine releases of radioactivity to air, water and seepage basins that can be used for analyses of trends, environmental impact, etc. As used in this report, routine radioactive releases means radioactive materials that are released through established effluents from process facilities. This report provides a summary of radioactive releases that inflects the release values contained m records and documents from startup through 1985

  9. Sistema de Reconocimiento de Caracteres Orientado a Sistemas Android

    OpenAIRE

    Segura Morales, Oriol; Universitat Autònoma de Barcelona. Escola d'Enginyeria

    2014-01-01

    Este proyecto trata sobre un sistema de reconocimiento de caracteres que se implementa para sistemas Android en forma de aplicación para móvil y Tablet. La aplicación está orientada para que los niños aprendan a escribir de una forma más amena. El sistema utiliza el patrón de diseño Modelo-Vista-Controlador para separar la lógica del sistema de la interfaz visual. En la interfaz, el sistema pide que se escriba un carácter utilizando la pantalla táctil y una vez el usuario lo ha escrito el sis...

  10. Implementation of a model of atmospheric dispersion and dose calculation in the release of radioactive effluents in the Nuclear Centre

    International Nuclear Information System (INIS)

    Cruz L, C. A.

    2015-01-01

    In the present thesis, the software DERA (Dispersion of Radioactive Effluents into the Atmosphere) was developed in order to calculate the equivalent dose, external and internal, associated with the release of radioactive effluents into the atmosphere from a nuclear facility. The software describes such emissions in normal operation, and not considering the exceptional situations such as accidents. Several tools were integrated for describing the dispersion of radioactive effluents using site meteorological information (average speed and wind direction and the stability profile). Starting with the calculation of the concentration of the effluent as a function of position, DERA estimates equivalent doses using a set of EPA s and ICRP s coefficients. The software contains a module that integrates a database with these coefficients for a set of 825 different radioisotopes and uses the Gaussian method to calculate the effluents dispersion. This work analyzes how adequate is the Gaussian model to describe emissions type -puff-. Chapter 4 concludes, on the basis of a comparison of the recommended correlations of emissions type -puff-, that under certain conditions (in particular with intermittent emissions) it is possible to perform an adequate description using the Gaussian model. The dispersion coefficients (σ y and σ z ), that using the Gaussian model, were obtained from different correlations given in the literature. Also in Chapter 5 is presented the construction of a particular correlation using Lagrange polynomials, which takes information from the Pasquill-Gifford-Turner curves (PGT). This work also contains a state of the art about the coefficients that relate the concentration with the equivalent dose. This topic is discussed in Chapter 6, including a brief description of the biological-compartmental models developed by the ICRP. The software s development was performed using the programming language Python 2.7, for the Windows operating system (the XP

  11. Radioactive materials released from nuclear power plants. Annual report 1977

    International Nuclear Information System (INIS)

    Decker, T.R.

    1978-11-01

    Releases of radioactive materials in airborne and liquid effluents from commercial light water reactors during 1977 have been compiled and reported. Data on solid waste shipments as well as selected operating information have been included. This report supplements earlier annual reports issued by the former Atomic Energy Commission and the Nuclear Regulatory Commission. The 1977 release data are compared with previous years releases in tabular form. Data covering specific radionuclides are summarized

  12. Combustion of Biogas Released from Palm Oil Mill Effluent and the Effects of Hydrogen Enrichment on the Characteristics of the Biogas Flame

    Directory of Open Access Journals (Sweden)

    Seyed Ehsan Hosseini

    2015-01-01

    Full Text Available Biogas released from palm oil mill effluent (POME could be a source of air pollution, which has illustrated negative effects on the global warming. To protect the environment from toxic emissions and use the energy of POME biogas, POME is conducted to the closed digestion systems and released biogas is captured. Since POME biogas upgrading is a complicated process, it is not economical and thus new combustion techniques should be examined. In this paper, POME biogas (40% CO2 and 60% CH4 has been utilized as a fuel in a lab-scale furnace. A computational approach by standard k-ε combustion and turbulence model is applied. Hydrogen is added to the biogas components and the impacts of hydrogen enrichment on the temperature distribution, flame stability, and pollutant formation are studied. The results confirm that adding hydrogen to the POME biogas content could improve low calorific value (LCV of biogas and increases the stability of the POME biogas flame. Indeed, the biogas flame length rises and distribution of the temperature within the chamber is uniform when hydrogen is added to the POME biogas composition. Compared to the pure biogas combustion, thermal NOx formation increases in hydrogen-enriched POME biogas combustion due to the enhancement of the furnace temperature.

  13. Polishing of anaerobic secondary effluent by Chlorella vulgaris under low light intensity.

    Science.gov (United States)

    Cheng, Tuoyuan; Wei, Chun-Hai; Leiknes, TorOve

    2017-10-01

    To investigate anaerobic secondary effluent polishing by microalgae (Chlorella vulgaris) under low light intensity (14μmol/m 2 /s), bubbling column reactors were operated in batches of 8 d with initial ammonium nitrogen 10-50mg/L, initial phosphate phosphorus 2-10mg/L and microalgal seed 40mg/L. Maximum microalgal biomass and minimum generation time were 370.9mg/L and 2.5d, respectively. Nitrogen removal (maximum 99.6%) was mainly attributed to microalgal growth rate, while phosphorus removal (maximum 49.8%) was related to microalgal growth rate, cell phosphorus content (maximum 1.5%) and initial nutrients ratio. Dissolved microalgal organics release in terms of chemical oxygen demand (maximum 63.2mg/L) and hexane extractable material (i.e., oil and grease, maximum 8.5mg/L) was firstly reported and mainly affected by nitrogen deficiency and deteriorated effluent quality. Ultrafiltration critical flux (16.6-39.5L/m 2 /h) showed negative linear correlation to microalgal biomass. Anaerobic membrane bioreactor effluent polishing showed similar results with slight inhibition to synthetic effluent. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Monitoring of releases from an irradiated fuel reprocessing plant

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1978-01-01

    At its UP 2 plant, the La Hague facility reprocesses irradiated fuel by the PUREX process. The fuel stems from graphite/gas, natural-uranium reactors and pressurized or boiling water enriched-uranium reactors. The gaseous effluents are collected and purified by high-efficiency washing and filtration. After purification the gas stream is discharged into the atmosphere by a single stack, 100m high and 6m in diameter, located at a high point on the site (184m). The radionuclides released into the air are: krypton-85, iodine-129 and -131, and tritium. The liquid effluents are collected by drainage systems, which transfer them to the effluent treatment station in the case of active or suspect solutions. Active solutions undergo treatment by chemical and physical processes. After purification the waste water is released into the sea by an underwater drainage system 5km long, which brings the outlet point into the middle of a tidal current 2km offshore. The radionuclides contained in the purified waste water are fission products originating from irradiated fuels in only slightly variable proportions, in which ruthenium-rhodium-106 predominates. Traces of the transuranium elements are also found in these solutions

  15. An Assessment of Physicochemical Parameters of Selected Industrial Effluents in Nepal

    Directory of Open Access Journals (Sweden)

    Abhinay Man Shrestha

    2017-01-01

    Full Text Available It is a well-known fact that the effluents released from the industries and environmental degradation go hand in hand. With the ongoing global industrialization this problem has been further aggravated. As such, Nepal is no exception. Hundreds of industries are being registered in the country annually which inevitably brings the issues regarding environmental pollution. This study has been conducted with samples of wastewater from 5 different industrial sites in 4 districts of Nepal, namely, Makwanpur, Sunsari, Morang, and Kathmandu, among which two were Waste Water Treatment Plants which treated the combined effluents collected from various sources. The other three sites were from wires and cables industry, paint manufacturing industry, and plastic cutting industry. The physicochemical parameters analysed were pH, temperature, conductivity, turbidity, and Cu, Cr, SO42-, and PO43- levels. Possible onsite measurements were recorded using portable, handheld devices whereas other parameters were assessed in the laboratory. The observed parameter levels in the collected samples were compared against the available Nepal national standards for industrial effluents and in the absence of standards for industrial effluents, with other relevant standard levels. Most of the parameters analysed were within the permissible limits with the exception of pH and Cr levels in some sites.

  16. Preparation of radiological effluent technical specifications for nuclear power plants. a guidance manual for users of standard technical specifications

    International Nuclear Information System (INIS)

    Boegli, J.S.; Bellamy, R.R.; Britz, W.L.; Waterfield, R.L.

    1978-10-01

    The purpose of this manual is to describe methods found acceptable to the staff of the U.S. Nuclear Regulatory Commission (NRC) for the calculation of certain key values required in the preparation of proposed radiological effluent Technical Specifications using the Standard Technical Specifications for light-water-cooled nuclear power plants. This manual also provides guidance to applicants for operating licenses for nuclear power plants in the preparation of proposed radiological effluent Technical Specifications or in preparing requests for changes to existing radiological effluent Technical Specifications for operating licenses. The manual additionally describes current staff positions on the methodology for estimating radiation exposure due to the release of radioactive materials in effluents and on the administrative control of radioactive waste treatment systems

  17. Suspended solids in liquid effluents

    International Nuclear Information System (INIS)

    McGrath, J.J.

    1988-06-01

    An international literature review and telephone mail survey was conducted with respect to technical and regulatory aspects of suspended solids in radioactive liquid wastes from nuclear power stations. Results of the survey are summarized and show that suspended solids are an important component of some waste streams. The data available, while limited, show these solids to be associated largely with corrosion products. The solids are highly variable in quantity, size and composition. Filtration is commonly applied for their removal from liquid effluents and is effective. Complex interactions with receiving waters can result in physical/chemical changes of released radionuclides and these phenomena have been seen as reason for not applying regulatory controls based on suspended solids content. 340 refs

  18. Experimental study and phenomenological modeling of the hydrolysis of tritiated sodium: influence of experimental conditions on the tritium distribution in the effluents

    International Nuclear Information System (INIS)

    Chassery, Aurelien

    2014-01-01

    Within the framework of the decommissioning of fast reactors, several processes are under investigation regarding sodium disposal. One of them rests on the implementation of the sodium-water reaction (SWR), in a controlled and progressive way, to remove residual sodium containing impurities such as sodium hydrides, sodium oxides and tritiated sodium hydrides. Such a hydrolysis releases some amount of energy and produces a liquid effluent, composed of a solution of soda, and a gaseous effluent, composed of hydrogen, steam and an inert gas. The tritium, originally into the sodium as a soluble (T - ) or precipitate form (NaT), will be distributed between the liquid and gaseous effluent, and according to two chemical forms, the tritium hydride HT and the tritiated water HTO. HTO being 10,000 times more radio-toxic than HT, a precise knowledge of the mechanisms governing the distribution of tritium is necessary in order to estimate the exhaust gas releases and design the process needed to treat the off-gas before its release into the environment. An experimental study has been carried out in order to determine precisely the phenomena involved in the hydrolysis. The influence of the experimental conditions on the tritium distribution has been tested. The results of this study leaded to a phenomenological description of the tritiated sodium hydrolysis that will help to predict the composition of the effluents, regarding tritium. (author) [fr

  19. Control of effluents and environmental surveillance of the CEA centres. 1997 status

    International Nuclear Information System (INIS)

    1998-06-01

    The environmental quality in the vicinity of CEA facilities is a major concern of the safety policy of the CEA. The aim of this document is to inform the public about the gaseous and liquids radioactive effluents released by the CEA centres under the permission of the ministry. It provides a status of the effluents and of the radioactivity levels measured near the CEA centres in 1997, using air, water, vegetation and milk samples. A comparison is made with the measurements performed during the 1993-1996 period. The data presented comes from the regulatory registers transmitted to the agency for the protection against ionizing radiations (OPRI) which belongs to the ministry of health. (J.S.)

  20. Impact of industrial effluent on growth and yield of rice (Oryza sativa L.) in silty clay loam soil.

    Science.gov (United States)

    Anwar Hossain, Mohammad; Rahman, Golum Kibria Muhammad Mustafizur; Rahman, Mohammad Mizanur; Molla, Abul Hossain; Mostafizur Rahman, Mohammad; Khabir Uddin, Mohammad

    2015-04-01

    Degradation of soil and water from discharge of untreated industrial effluent is alarming in Bangladesh. Therefore, buildup of heavy metals in soil from contaminated effluent, their entry into the food chain and effects on rice yield were quantified in a pot experiment. The treatments were comprised of 0, 25%, 50%, 75% and 100% industrial effluents applied as irrigation water. Effluents, initial soil, different parts of rice plants and post-harvest pot soil were analyzed for various elements, including heavy metals. Application of elevated levels of effluent contributed to increased heavy metals in pot soils and rice roots due to translocation effects, which were transferred to rice straw and grain. The results indicated that heavy metal toxicity may develop in soil because of contaminated effluent application. Heavy metals are not biodegradable, rather they accumulate in soils, and transfer of these metals from effluent to soil and plant cells was found to reduce the growth and development of rice plants and thereby contributed to lower yield. Moreover, a higher concentration of effluent caused heavy metal toxicity as well as reduction of growth and yield of rice, and in the long run a more aggravated situation may threaten human lives, which emphasizes the obligatory adoption of effluent treatment before its release to the environment, and regular monitoring by government agencies needs to be ensured. Copyright © 2015. Published by Elsevier B.V.

  1. Green methodology for the recovery of Cr (VI from tannery effluent using newly synthesized quaternary ammonium salt

    Directory of Open Access Journals (Sweden)

    K.S. Yoganand

    2017-02-01

    Full Text Available Leather tanning industries release effluents into the river through various canals. These effluents contain chromium (VI contaminating the river and the ground water as well. To fix a solution for this issue a simple and selective solvent extraction method has been applied by using a newly synthesized quaternary ammonium salt viz 2-benzoylethylheptyldimethylammonium bromide. By varying the parameters such as quaternary ammonium salts, sulfuric acid, pH, solvents, equilibration time and aqueous organic ratio the extraction efficiency has been determined.

  2. Computer programs at SRL to evaluate environmental effects SRP operations and postulated accidental releases

    International Nuclear Information System (INIS)

    Cooper, R.E.

    1975-09-01

    Savannah River Plant operations unavoidably result in the release of some chemical and radioactive effluents to the environs. The most environmentally significant releases are gaseous effluents to the atmosphere; computer codes dealing with these atmospheric releases are discussed in this report. There is a wide variety of effluents, both chemical and radioactive, to be considered, and each must be correlated with meteorological dispersion data as a function of time to estimate the environmental effects. In addition, large inventories of toxic and radioactive materials in some facilities represent a potential for accidental releases. Accidents are postulated for these facilities, and the environmental effects of resulting releases are again evaluated by correlating with meteorological dispersion data. In accordance with AEC Regulatory Guide 23, a 2-year meteorological data base is used in performing all analyses. Due to the diversity of possible releases and the large meteorological data base, the environmental analyses are necessarily performed with the aid of a large computer facility. Several computer programs have been written to facilitate these analyses according to the type of analysis desired. The computer programs described in this report are basically of three categories: probability distributions of estimated concentrations or doses as a function of distance from a point of origin, estimates of average concentrations or doses over a specified time period such as annual averages, and some miscellaneous programs in support of the first two categories to optimize the use of the computing facility. A complete documentation of each program is included with a program listing and sample input-output

  3. Water balance modelling of a uranium mill effluent management system

    Science.gov (United States)

    Plagnes, Valérie; Schmid, Brad; Mitchell, Brett; Judd-Henrey, Ian

    2017-06-01

    A water balance model was developed to forecast the management strategy of a uranium mill effluent system, located in northern Saskatchewan, Canada. Mining and milling operations, such as pit dewatering or treated effluent release, can potentially influence the hydrology and the water quality downstream of the operations. This study presents the methodology used to predict water volumes and water quality discharging downstream in surface water bodies. A compartment model representing the three subsequent lakes included in the management system was set up using the software GoldSim®. The water balance allows predicting lake volumes at the daily time step. A mass balance model developed for conservative elements was also developed and allows validating the proportions of inputs and outputs issued from the water balance model. This model was then used as predictive tool to evaluate the impact of different scenarios of effluents management on volumes and chemistry of surface water for short and longer time periods. An additional significant benefit of this model is that it can be used as an input for geochemical modelling to predict the concentrations of all constituents of concern in the receiving surface water.

  4. Effect of soda ash industry effluent on agarophytes, alginophytes and carrageenophyte of west coast of India.

    Science.gov (United States)

    Jadeja, R N; Tewari, A

    2009-02-15

    This paper presents the results of a study on the impact of the effluent released by the soda ash industry on important red and brown macro algal species Gelidiella acerosa, Gracilaria corticata, Soleria robusta, Sargassum tenerrimum, Padina tetrastromatica in the tidal zone around Veraval, on the west coast of India, in the lowest low water tide of December 2003. The study examined the effect of effluent discharge on availability of biomass and percentage of phyco-colloids extraction such as agar, alginic acid and carrageen of these commercial seaweeds.

  5. System Aero-Accelator for the purification of biodegradable effluents; Sistema aero-accelator para la depuracion de efluentes biodegradables (I)

    Energy Technology Data Exchange (ETDEWEB)

    Bosque Hernandez, J. L. del; Martin Sanchez, J. L. [Universidad de Salamanca (Spain)

    2000-07-01

    The contamination of the waters is one of the factors that contributes to the deterioration of our environment and since it is a very limited one its treatment descontaminant it is one of the politic's main objectives and environmental administration at all the levels, being spread to the total purification of the generated residual effluents. To reach this objective, big technological efforts are required that allow next to the creation of new processes, the adaptation of the processes existent depuratives, increasing the effectiveness of the same ones. One of the techniques of purification of possible recovery is the Compact System of active mires Aero-Accelator. Presently work is designed and it builds a plant pilot with Aero-Accelator geometry to study its behavior in the treatment of effluents of urban type with different loads pollutants. (Author) 16 refs.

  6. Qualidade da água de córrego em função do lançamento de efluente de abate de bovino Water quality of stream due to release of effluent from cattle slaughter

    Directory of Open Access Journals (Sweden)

    Erlon A. Ribeiro

    2013-04-01

    Full Text Available Objetivou-se, com este trabalho, avaliar a influência do lançamento de efluente de um frigorífico de abate de bovinos sobre a qualidade da água do córrego Jurubatuba, Anápolis, GO. Analisaram-se: o efluente tratado antes do lançamento no córrego e a água do córrego 50 m à montante e 50 e 500 m à jusante do ponto de lançamento. Foram realizadas oito coletas no período seco (08/07 a 24/09/09 e oito no chuvoso (01/10 a 03/12/09 quantificando o pH, turbidez, oxigênio dissolvido, saturação de oxigênio, carbono orgânico total, cloro, alumínio, amônia, cobre, manganês, ferro total, fósforo total, sulfeto, sódio, demanda biológica de oxigênio, demanda química de oxigênio, nitrogênio total, condutividade elétrica, nitrato e nitrito. Os valores de pH, NH3-, Zn+, sulfeto, NO3-, e cloreto nos dois períodos e em todos os pontos analisados no córrego, atenderam aos critérios para água de classe 2; o Na+, NH3-, carbono orgânico total, P total, CE e NO3-, aumentaram nos pontos após o lançamento do efluente. A turbidez, Al e o Mg no efluente tratado foram, nos períodos seco e chuvoso, maiores ao permitido para corpos hídricos de classe 2; o Fe total no efluente apresentou risco médio para uso na irrigação.The objective of this study was to evaluate the influence of release of effluent from a cattle slaughter house on water quality of Jurubatuba stream, in Anápolis - Goiás. The treated effluent before release into the stream, the stream water at 50 m upstream, and 50 and 500 m downstream from the launch place were analysed. Eight samples were taken during the dry season (08/07 to 24/09/2009 and eight in the rainy season (01/10 to 03/12/2009, quantifying pH, turbidity, dissolved oxygen, oxygen saturation, total organic carbon, chlorine, aluminum, ammonia, copper, manganese, total iron, total phosphorus, sulfate, sodium, biological oxygen demand, chemical oxygen demand, total nitrogen, electrical conductivity, nitrate and

  7. ANCCLI Scientific Committee - Opinion related to the modification request for the authorisation of water takings and releases of liquid and gaseous effluents of the Cruas-Meysse CNPE made by EDF under Article 26 of Decree nr 2007-1557 of the 2 November 2007. Study performed at the request of the Cruas-Meysse CLI

    International Nuclear Information System (INIS)

    2012-01-01

    This report first makes some comments on modification requests made by the operator (EDF) and on the related prescription projects. Five modifications have been proposed: 1) the implementation of an anti-tartar treatment for condenser cooling circuits by continuous acid vaccination and by complementary point acid injection, 2) the implementation of a treatment against biofouling and pathogen micro-organisms in condenser cooling circuits by massive chlorination under controlled pH, 3) the evolution of the secondary circuit chemical conditioning with the implementation of an 'intermediate pH'-type conditioning and/or an ethanolamine-based conditioning, 4) the taking of head-race channel dredging and pumping station de-silting operations into account, 5) other modifications related to effluent release authorisations (tritium volume activity in tanks, low limit of Rhone flow rate for the release of liquid radioactive effluents, limits of copper and zinc releases due to condenser wear). Some comments are then made about the monitoring of the environment, and about some prescription projects which are beyond the operator's request regarding release limits and the follow-up procedure related to the modification of release authorisations

  8. Psiconeuroinmunología: Conexiones entre sistema nervioso y sistema inmune

    Directory of Open Access Journals (Sweden)

    García López, Luis Joaquín

    2008-09-01

    Full Text Available La psiconeuroinmunología es una nueva parcela de la ciencia que apenas lleva tres décadas, pero que en los últimos años ha sido objeto de una enorme atención por diversos grupos de investigación. El articulo pretende exponer brevemente cómo están organizados los sistemas inmune y neuroendocrino, para después presentar los hallazgos que hasta el momento intentan dar explicación de las relaciones entre ambos con el sistema nervioso, así como las influencias de unos sobre otros, más concretamente expresar la relación entre los tres sistemas responsables de la defensa del organismo y, más ampliamente, de su mantenimiento homeostático. Cuando se trata de amenazas, el sistema nervioso central tiene que decidir qué sistema se pone en marcha, el sistema de estrés como energía para el ataque o la huida (un animal que nos quiere atacar, el sistema inmune para neutralizar el antígeno (un virus que nos quiere atacar o ambos (la energía es necesaria también para el sistema inmune. Como parece ser que en muchas ocasiones la depresión aparece tras los esfuerzos infructuosos de puesta en marcha de estrategias de afrontamiento, también hemos repasado sucintamente algunas investigaciones que relacionan al sistema inmune con la depresión, así como con los trastornos del sueño. Se finaliza con las aportaciones que la psicología puede ofrecer a nivel terapéutico.

  9. CONCAWE effluent speciation project

    Energy Technology Data Exchange (ETDEWEB)

    Leonards, P.; Comber, M.; Forbes, S.; Whale, G.; Den Haan, K.

    2010-09-15

    In preparation for the implementation of the EU REACH regulation, a project was undertaken to transfer the high-resolution analytical method for determining hydrocarbon blocks in petroleum products by comprehensive two-dimensional gas chromatography (GCxGC) to a laboratory external to the petroleum industry (Institute for Environmental Studies (IVM) of the VU University of Amsterdam). The method was validated and used for the analysis of petroleum hydrocarbons extracted from refinery effluents. The report describes the technology transfer and the approaches used to demonstrate the successful transfer and application of the GCxGC methodology from analysing petroleum products to the quantitative determination of hydrocarbon blocks in refinery effluents. The report describes all the methods used for all the determinations on the effluent samples along with an overview of the results obtained which are presented in summary tables and graphs. These data have significantly improved CONCAWE's knowledge of what refineries emit in their effluents. A total of 111 Effluent Discharge Samples from 105 CONCAWE refineries in Europe were obtained in the period June 2008 to March 2009. These effluents were analysed for metals, standard effluent parameters (including COD, BOD), oil in water, BTEX and volatile organic compounds. The hydrocarbon speciation determinations and other hydrocarbon analyses are also reported. The individual refinery analytical results are included into this report, coded as per the CONCAWE system. These data will be, individually, communicated to companies and refineries. The report demonstrates that it is feasible to conduct a research programme to investigate the fate and effects of hydrocarbon blocks present in discharged refinery effluents.

  10. Releases of radioactivity from uranium mills and effluent treatment costs

    International Nuclear Information System (INIS)

    Witherspoon, J.P.; Sears, M.B.; Blanco, R.E.

    1977-01-01

    Airborne releases of radioactive materials from uranium milling to the environment consist of ore dust, yellowcake dust, tailings dust, and radon gas while the mill is active. After a mill has ceased operations, tailings may be stabilized to minimize or prevent airborne releases of radioactive particulates. However, radon gas will continue to be released in amounts inversely proportional to the degree of stabilization treatment (and expense). Liquid waste disposal is by evaporation and natural seepage to the ground beneath the tailings impoundment area. The release of radioactive materials (and potential radiation exposures) determines the majority of costs associated with minimizing the environmental impact of uranium milling. Radwaste treatments to reduce estimated radiation doses to individuals to 3 to 5% of those received with current milling practices are equivalent to $0.66 per pounds of U 3 O 8 and 0.032 mill per kWhr of electricity. This cost would cover a high efficiency reverse jet bag filter and high energy venturi scrubbers for dusts, neutralization of liquids, and an asphalt-lined tailings basin with a clay core dam to reduce seepage. In addition, this increased cost would cover stabilization of tailings, after mill closure, with a 1-in. asphalt membrane topped by 2 ft of earth and 0.5 ft of crushed rock to provide protection against future leaching and wind erosion. The cost of reducing the radiological hazards associated with uranium milling to this degree would contribute about 0.4% to the current total cost of nuclear power

  11. INEEL Liquid Effluent Inventory

    Energy Technology Data Exchange (ETDEWEB)

    Major, C.A.

    1997-06-01

    The INEEL contractors and their associated facilities are required to identify all liquid effluent discharges that may impact the environment at the INEEL. This liquid effluent information is then placed in the Liquid Effluent Inventory (LEI) database, which is maintained by the INEEL prime contractor. The purpose of the LEI is to identify and maintain a current listing of all liquid effluent discharge points and to identify which discharges are subject to federal, state, or local permitting or reporting requirements and DOE order requirements. Initial characterization, which represents most of the INEEL liquid effluents, has been performed, and additional characterization may be required in the future to meet regulations. LEI information is made available to persons responsible for or concerned with INEEL compliance with liquid effluent permitting or reporting requirements, such as the National Pollutant Discharge Elimination System, Wastewater Land Application, Storm Water Pollution Prevention, Spill Prevention Control and Countermeasures, and Industrial Wastewater Pretreatment. The State of Idaho Environmental Oversight and Monitoring Program also needs the information for tracking liquid effluent discharges at the INEEL. The information provides a baseline from which future liquid discharges can be identified, characterized, and regulated, if appropriate. The review covered new and removed buildings/structures, buildings/structures which most likely had new, relocated, or removed LEI discharge points, and at least 10% of the remaining discharge points.

  12. Radioactive materials released from nuclear power plants: Annual report, 1984

    Energy Technology Data Exchange (ETDEWEB)

    Tichler, J.; Norden, K.; Congemi, J.

    1987-08-01

    Releases of radioactive materials in airborne and liquid effluents from commercial light water reactors during 1984 have been compiled and reported. Data on solid waste shipments as well as selected operating information have been included. This report supplements earlier annual reports issued by the former Atomic Energy Commission and the Nuclear Regulatory Commission. The 1984 release data are summarized in tabular form. Data covering specific radionuclides are summarized.

  13. Meso-meteorological effect of thermal releases from nuclear power plants in the GW range

    International Nuclear Information System (INIS)

    Bahloul, C.; Le Berre, P.

    1975-01-01

    A comparison is made between the energy released by nuclear power plants into the environment and the energy brought into action by meso-meteorological phenomena. Observations on the occasion of important heat release (forest fires) are made and compared with the thermal effluents generated by nuclear power plants [fr

  14. Biogas Production From Cassava Starch Effluent Using Microalgae As Biostabilisator

    Directory of Open Access Journals (Sweden)

    B. Budiyono

    2011-07-01

    Full Text Available The rapid growing of Indonesian population is emerging several critical national issues i.e. energy, food, environmental, water, transportation, as well as law and human right. As an agricultural country, Indonesia has abundant of biomass wastes such as agricultural wastes include the cassava starch wastes. The problem is that the effluent from cassava starch factories is released directly into the river before properly treatment. It has been a great source of pollution and has caused environmental problems to the nearby rural population. The possible alternative to solve the problem is by converting waste to energy biogas in the biodigester. The main problem of the biogas production of cassava starch effluent is acid forming-bacteria quickly produced acid resulting significantly in declining pH below the neutral pH and diminishing growth of methane bacteria. Hence, the only one of the method to cover this problem is by adding microalgae as biostabilisator of pH. Microalgae can also be used as purifier agent to absorb CO2.The general objective of this research project was to develop an integrated process of biogas production and purification from cassava starch effluent by using biostabilisator agent microalgae. This study has been focused on the used of urea, ruminant, yeast, microalgae, the treatment of gelled and ungelled feed for biogas production, pH control during biogas production using buffer Na2CO3, and feeding management in the semi-continuous process of biogas production. The result can be concluded as follows: i The biogas production increased after cassava starch effluent and yeast was added, ii Biogas production with microalgae and cassava starch effluent, yeast, ruminant bacteria, and urea were 726.43 ml/g total solid, iii Biogas production without  microalgae was 189 ml/g total solid.

  15. Tritium recapture behavior at a nuclear power reactor due to airborne releases.

    Science.gov (United States)

    Harris, Jason T; Miller, David W; Foster, Doug W

    2008-08-01

    This paper describes the initiatives taken by Cook Nuclear Plant to study the on-site behavior of recaptured tritium released in its airborne effluents. Recapture is the process where a released radioactive effluent, in this case tritium, is brought back on-site through some mechanism. Precipitation, shifts in wind direction, or anthropogenic structures that restrict or alter effluent movement can all lead to recapture. The investigation was started after tritium was detected in the north storm drain outfall. Recent inadvertent tritium releases by several other nuclear power plants, many of which entered the groundwater, have led to increased surveillance and scrutiny by regulatory authorities and the general public. To determine the source of tritium in the outfall, an on-site surface water, well water, rainwater and air-conditioning condensate monitoring program was begun. Washout coefficients were also determined to compare with results reported by other nuclear power plants. Program monitoring revealed detectable tritium concentrations in several precipitation sample locations downwind of the two monitored containment building release vents. Tritium was found in higher concentrations in air-conditioning condensate, with a mean value of 528 Bq L(-1) (14,300 pCi L(-1)). The condensate, and to a lesser extent rainwater, were contributing to the tritium found in the north storm drain outfall. Maximum concentration values for each sample type were used to estimate the most conservative dose. A maximum dose of 1.1 x 10(-10) mSv (1.1 x 10(-8) mrem) total body was calculated to determine the health impact of the tritium detected.

  16. Liquid Effluent Retention Facility/Effluent Treatment Facility Hazards Assessment

    International Nuclear Information System (INIS)

    Simiele, G.A.

    1994-01-01

    This document establishes the technical basis in support of Emergency Planning activities for the Liquid Effluent Retention Facility and Effluent Treatment Facility the Hanford Site. The document represents an acceptable interpretation of the implementing guidance document for DOE ORDER 5500.3A. Through this document, the technical basis for the development of facility specific Emergency Action Levels and the Emergency Planning Zone is demonstrated

  17. Atmospheric dispersion of radionuclides released by a nuclear plant

    International Nuclear Information System (INIS)

    Barboza, A.A.

    1989-01-01

    A numerical model has been developed to simulate the atmospheric dispersion of radionuclides released by a nuclear plant operating under normal conditions. The model, based on gaussian plume representation, accouts for and evaluates several factors which affect the concentraction of effluents in the atmosphere, such as: ressuspension, deposition, radioactive decay, energy and type of the radiation emitted, among others. The concentraction of effluents in the atmosphere is calculated for a uniform mesh of points around the plant, allowing the equivalent doses to be then evaluated. Simulations of the atmosphere dispersion of radioactive plumes of Cs 137 and Ar 41 have been performed assuming a constant rate of release, as expected from the normal operation of a nuclear plant. Finally, this work analyzes the equivalent doses at ground level due to the dispersion of Cs 137 and Ar 41 , accumulated over one year and determines the isodose curves for a hypothetical site. (author) [pt

  18. 40 CFR 426.113 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Television Picture... applicable to the abrasive polishing and acid polishing waste water streams. Effluent characteristic Effluent...

  19. 40 CFR 427.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Elastomeric Binder) Subcategory § 427.43 Effluent limitations guidelines representing the degree of effluent...

  20. 40 CFR 427.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ASBESTOS MANUFACTURING POINT SOURCE CATEGORY Asbestos Paper (Starch Binder) Subcategory § 427.33 Effluent limitations guidelines representing the degree of effluent...

  1. Decision no 2010-DC-0188 by the Nuclear Safety Authority on the 7. of July 2010 specifying to Electricite de France-Societe Anonyme (EDF-SA) the limits of releases in the environment of liquid and gaseous effluents for the operation of Flamanville 1 (IBN n 108), Flamanville 2 (INB n 109) and Flamanville 3 (INB n 167) reactors

    International Nuclear Information System (INIS)

    2010-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents by the three Flamanville nuclear reactors operated by Electricite de France-Societe Anonyme (EDF-SA). Tables present the limits for different gaseous and liquid radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine hydrate, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  2. 40 CFR 426.112 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Television... stream): Effluent characteristic Effluent limitations Maximum for any 1 day Average of daily values for...

  3. Measurement of actinides in samples from effluent air, primary coolant and effluent water of nuclear power stations in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Winkler, R.; Hoetzl, H.; Rosner, G.

    1977-01-01

    Since the middle of 1973 the alpha radioactivity of a number of aerosol filters from the stack monitoring systems of some nuclear power stations, of water effluent samples from all german nuclear power stations and of samples from the primary coolant water of one nuclear power reactor was measured. Essentially, the following procedures of sample preparation for alpha spectrometry of the samples in large area gridded ionization chambers were used; cold ashing of the aerosol samples in 'excited' oxygen, coprecipitation of the alpha emitters from the effluent water samples with iron hydroxide and subsequent cold ashing of the precipitate, and evaporation of the samples from the primary cycle on stainless steel plates. The following transuranium nuclides, or some of them, were found in the samples of the primary coolant and in several aerosol filter samples: Pu-239/240, Pu-238 and/or Am-241, Cm-242 and Cm-244. Cm-242 contributes most to the alpha radioactivity in fresh samples. In the effluent water samples Cm-242, Pu-239/240 and Pu-238 and/or Am-241 were identified in some cases, in one case also Cm-244. Detection limits of the procedures used for the analysis of the above stated transuranium nuclides were in the order of 0,1 fCi per m 3 for the aerosol samples and of 0.2 pCi per 1 for the liquid samples. For the effluent air and water samples in most cases specific activities near the detection limit or somewhat higher were found. On the basis of the measurements, an estimation of the annual actinides releases from nuclear power stations in the Federal Republic of Germany is given

  4. Effluent control for the uranium mine area at Pocos de Caldas, Brazil

    International Nuclear Information System (INIS)

    Rochedo, E.R.R.; Vasconcellos, L.M.H.

    2005-01-01

    Derived levels for effluents control for the Industrial Complex of Pocos de Caldas - CIPC, Brazil were set based on the IAEA recommendation for the dose assessment of critical groups. Although the industry has stopped the uranium extraction in 1988, the installation is kept under regulatory control, as it has not yet been decommissioned. A screening procedure was set to control the effluent releases from the three main areas, the open pit mine area, the tailings dam and the waste rock piles. To each one of these areas, the dose restriction of 0,3 mSv/a was adopted, since each effluent refers to a different critical group. Monthly-composed samples are collected weekly at each outflow and sent to IRD. The radionuclides analyzed are 238 U, 226 Ra, 210 Pb, 232 Th and 228 Ra. If the activity concentration for any of these nuclides surpasses the established reference level to that particular source, a complete dose assessment for the critical group is performed using the computer program, Monitor, built based on IAEA recommendations for dose assessment to critical groups. The results show that Brazilian regulations related to public exposure are being accomplished by the installation operation. It is pointed out the relevance of maintaining the current treatment to the acid drainages and effluents from the tailings dam, until the whole area is properly decommissioned. (author)

  5. TBP production plant effluent treatment process

    International Nuclear Information System (INIS)

    Sriniwas, C.; Sugilal, G.; Wattal, P.K.

    2004-06-01

    TBP production facility at Heavy Water Plant, Talcher generates about 2000 litres of effluent per 200 kg batch. The effluent is basically an aqueous solution containing dissolved and dispersed organics such as dibutyl phosphate, butanol etc. The effluent has high salinity, chemical oxygen demand (30-80 g/L) and pungent odour. It requires treatment before discharge. A chemical precipitation process using ferric chloride was developed for quantitative separation of organics from the aqueous part of the effluent. This process facilitates the discharge of the aqueous effluent. Results of the laboratory and bench scale experiments on actual effluent samples are presented in this report. (author)

  6. Control system of liquid effluents generated in treatment with I-131; Sistema de control de efluentes liquidos generados en el tratamiento con I-131

    Energy Technology Data Exchange (ETDEWEB)

    Garcia M, T.; Ruiz C, M. A.; Angeles C, A.; Ramirez S, R., E-mail: teodoro.garcia@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2015-09-15

    In recent years, nuclear medicine has developed greatly in our country and around the world. Techniques for both medical diagnosis and therapy have increased the use of radiopharmaceuticals, notably the I-131. In Mexico there are around 150 nuclear medicine establishments authorized by the Comision Nacional de Seguridad Nuclear y Salvaguardias. Most of these establishments do not have an appropriate facility for the treatment of radioactive liquid effluents, to ensure compliance with the concentration limits established in the regulations. The Instituto Nacional de Investigaciones Nucleares (ININ) developed and implemented successfully, a control system of radioactive effluents (named SACEL) from a nuclear medicine facility. This system ensures an effective compliance with regulations and also better management and control of these radioactive effluents. Calculations and design of SACEL were made with respect to I-131, because is one of the most commonly used in radiotherapy and medical diagnostics, besides its half-life is greater in relation to other radionuclides. SACEL is comprised of four storage tanks and decay and a fifth tank for measuring the concentration of I-131 and later discharge to the drain; these tanks are connected to an automated system that controls the effluents passage. The calculation to determine the volume of the tanks was carried out according to the demand that has the hospital, to the maximum activity being poured in effluents and time required to decay. In this paper the design and installation of SACEL system, in addition to functioning as a facility that enables the Hospital meet the required standards is presented. Dose calculations performed with MCNPX and the methodology used in the calibration of the detection system is also presented. (Author)

  7. Methodological studies for deriving release criteria for liquid effluents from medical installations

    International Nuclear Information System (INIS)

    Shu, Jane; Comissao Nacional de Energia Nuclear; Rochedo, Elaine R.R.; Heilbron Filho, Paulo F.L.; Crispim, Verginia R.

    2009-01-01

    This work aims to develop a methodology for the assessment of clearance limits for the release of liquid waste arising from medical installations using radionuclides for medical diagnostic purposes in the town of Rio de Janeiro. The results will be used to assess the need to justify or to revise the current clearance values as specified in regulation CNEN-NE-6.05 - Radioactive Waste Management in Radioactive Facilities. The proposed methodology is based on the mathematical model recommended by the International Atomic Energy Agency, adapted to the observed release conditions in the study area. In order to turn the assessment as realistic as possible, two scenarios are simulated. The first scenario simulates the release to the sewage system with access to a sewer treatment stations. The second scenario simulates the releases without passing a treatment station, with direct outflow to surface water. Probabilistic assessments were performed using the Crystal Ball software. Distributions were than compared to current IAEA clearance criteria that include specific values for average and low probability scenarios. The results will be used to derive adequate clearance levels for radionuclides used in nuclear diagnostic medicine in Brazil according to the specific relevant release scenario. (author)

  8. Environmental and effluent monitoring at ANSTO sites, 2005-2006

    International Nuclear Information System (INIS)

    Hoffmann, Emmy L.; Loosz, Tom; Ferris, John M.; Harrison, Jennifer J.

    2006-01-01

    This report presents the results of ANSTO's environmental and effluent monitoring at the Lucas Heights Science and Technology Centre (LHSTC) and the National Medical Cyclotron (NMC) sites, from July 2005 to June 2006. Estimated effective doses to the critical group of members of the public potentially affected by routine airborne emissions from the LHSTC were less than 0.005 mSv/year. The maximum potential dose was 23% of the ANSTO ALARA objective of 0.02 mSv/year, much lower than the public dose limit of 1 mSv/year that is recommended by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). The effective doses to the critical group of members of the public potentially exposed to routine liquid effluent releases from the LHSTC have been realistically estimated as a quarter (or less) of the estimated doses to the critical group for airborne releases. The median tritium concentrations detected in groundwater and surface waters at the LHSTC were typically less than 2% of those set out in the Australian Drinking Water Guidelines. The airborne emissions from the NMC were below the ARPANSA-approved notification levels. Results of environmental monitoring at both ANSTO sites confirm that the facilities continue to be operated well within regulatory limits. ANSTO's routine operations at the LHSTC and NMC make only a very small addition to the natural background radiation dose of -1.5 mSv/year experienced by members of the Australian public

  9. Radiological consequences of radioactive effluents

    International Nuclear Information System (INIS)

    Clarke, R.H.

    1979-01-01

    A study of the differential radiological impact of the nuclear fuel cycle with and without plutonium recycle is being undertaken jointly by the National Radiological Protection Board and the Commissariat a l'Energie Atomique (CEA). A summary is given of the development of the methodology detailed in their first report to the Commission of the European Communities (CEC) (NRPB/CEA, A methodology for evaluating the radiological consequences of radioactive effluents released in normal operations. Luxembourg, CEC Doc. V/3011/75 EN (1979)). The Collective Effective Dose Equivalent Commitment was used in an attempt to assess the total health detriment. The application of the methodology within particular member states of the European Community has been discussed at seminars. Sensitivity analysis can identify the more important parameters for improving the accuracy of the assessment. (UK)

  10. Waste Treatment Plant Liquid Effluent Treatability Evaluation

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2001-01-01

    Bechtel National, Inc. (BNI) provided a forecast of the radioactive, dangerous liquid effluents expected to be generated by the Waste Treatment Plant (WTP). The forecast represents the liquid effluents generated from the processing of 25 distinct batches of tank waste through the WTP. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Fluor Hanford, Inc. (FH) evaluated the treatability of the WTP liquid effluents in the LERFIETF. The evaluation was conducted by comparing the forecast to the LERFIETF treatability envelope, which provides information on the items that determine if a liquid effluent is acceptable for receipt and treatment at the LERFIETF. The WTP liquid effluent forecast is outside the current LERFlETF treatability envelope. There are several concerns that must be addressed before the WTP liquid effluents can be accepted at the LERFIETF

  11. 40 CFR 417.162 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.162 Effluent limitations guidelines... available (BPT): (a) For normal liquid detergent operations the following values pertain: Effluent...

  12. Analysis of F-Canyon Effluents During the Dissolution Cycle with a Fourier Transform Infrared Spectrometer/Multipath Cell

    International Nuclear Information System (INIS)

    Villa, E.

    1999-01-01

    Air samples from F-Canyon effluents were collected at the F-Canyon stack and transported to a laboratory at the Savannah River Technology Center (SRTC) for analysis using a Fourier transform infrared spectrometer in conjunction with a multipath cell. Air samples were collected during the decladding and acid cuts of the dissolution of the irradiated aluminum-cladded slugs. The FTIR analyses of the air samples show the presence of NO2, NO, HNO2, N2O, SF6, and 85Kr during the dissolution cycle. The concentration time profiles of these effluents corresponded with expected release rates from the F-Canyon operations

  13. Decision no 2009-DC-0158 of the 15. of September 2009 by the Nuclear Safety Authority specifying instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installation n. 29 operated by the CIS Bio International on the district of Saclay (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installation operated by CIS Bio International in Saclay. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control and their transfer, the limit values for different compounds and species, the control of environment around the site, the information of authorities and of population

  14. Decentralised wastewater treatment effluent fertigation: preliminary ...

    African Journals Online (AJOL)

    Decentralised wastewater treatment effluent fertigation: preliminary technical assessment. ... living in informal settlements with the effluent produced being used on agricultural land. ... Banana and taro required 3 514 mm of irrigation effluent.

  15. Facility effluent monitoring plan for WESF

    Energy Technology Data Exchange (ETDEWEB)

    SIMMONS, F.M.

    1999-09-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the effluent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability.

  16. Degradation of fifteen emerging contaminants at microg L(-1) initial concentrations by mild solar photo-Fenton in MWTP effluents.

    Science.gov (United States)

    Klamerth, N; Rizzo, L; Malato, S; Maldonado, Manuel I; Agüera, A; Fernández-Alba, A R

    2010-01-01

    The degradation of 15 emerging contaminants (ECs) at low concentrations in simulated and real effluent of municipal wastewater treatment plant with photo-Fenton at unchanged pH and Fe=5 mg L(-1) in a pilot-scale solar CPC reactor was studied. The degradation of those 15 compounds (Acetaminophen, Antipyrine, Atrazine, Caffeine, Carbamazepine, Diclofenac, Flumequine, Hydroxybiphenyl, Ibuprofen, Isoproturon, Ketorolac, Ofloxacin, Progesterone, Sulfamethoxazole and Triclosan), each with an initial concentration of 100 microg L(-1), was found to depend on the presence of CO(3)(2-) and HCO(3)(-) (hydroxyl radicals scavengers) and on the type of water (simulated water, simulated effluent wastewater and real effluent wastewater), but is relatively independent of pH, the type of acid used for release of hydroxyl radicals scavengers and the initial H(2)O(2) concentration used. Toxicity tests with Vibrio fisheri showed that degradation of the compounds in real effluent wastewater led to toxicity increase. (c) 2009 Elsevier Ltd. All rights reserved.

  17. Silver precipitation from electrolytic effluents

    International Nuclear Information System (INIS)

    Rivera, I.; Patino, F.; Cruells, M.; Roca, A.; Vinals, J.

    2004-01-01

    The recovery of silver contained in electrolytic effluents is attractive due to its high economic value. These effluents are considered toxic wastes and it is not possible to dump them directly without any detoxification process. One of the most important way for silver recovery is the precipitation with sodium ditionite, sodium borohidride or hydrazine monohidrate. In this work, the most significant aspects related to the use of these reagents is presented. Results of silver precipitation with sodium ditionite from effluents containing thiosulfate without previous elimination of other species are also presented. silver concentration in the final effluents w <1 ppm. (Author) 15 refs

  18. Management of regenerant effluent waste at reprocessing plant, Tarapur- a new approach

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, Munish; Bajpai, D D; Mudaiya, Avinash; Varadarajan, N [Power Reactor Fuel Reprocessing Plant, Tarapur (India)

    1994-06-01

    Power Reactor Fuel Reprocessing (PREFRE) Plant, Tarapur has been processing zircaloy clad spent fuel arising from PHWR namely RAPS and MAPS. The plant has been provided with a water pool to receive and store the irradiated fuel assemblies from the reactor site for an interim period before they are taken up for chop-leach and further reprocessing by PUREX process. This paper highlights the important and innovative modifications like introduction of a cation exchanger for water polishing and using nitric acid as regenerant. The regenerant effluent (nitric acid) is recycled to the main process cells where it is mixed and further treated along with process waste stream. This is a step towards minimising effluent generation. The paper describes the advantages of modified system like operational simplification, manpower, man-rem saving and minimising release of activity to environment. 3 figs., 4 tabs.

  19. Environmental releases for calendar year 1994

    International Nuclear Information System (INIS)

    Gleckler, B.P.

    1995-07-01

    This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Orders. This report provides supplemental information to the Hanford Site Environmental Report. The Hanford Site Environmental Report provides an update on the environmental status of the entire Hanford Site. The sitewide annual report summarizes the degree of compliance of the Hanford Site with applicable environmental regulations and informs the public about the impact of Hanford operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities managed by the Westinghouse Hanford Company (WHC) and monitored by Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data on air emissions, liquid effluents, and hazardous substances released to the environment during calendar year 1994 from these facilities

  20. Genotoxicity of swine effluents.

    Science.gov (United States)

    Techio, V H; Stolberg, J; Kunz, A; Zanin, E; Perdomo, C C

    2011-01-01

    This study aimed at the investigation of genotoxic effects of swine effluents from different stages of a treatment system for swine wastes through bioassay of stamen hairs and micronuclei in Tradescantia (clone BNL 4430). No significant differences (p≥0.05) regarding the genic mutations were found in the bioassay of stamen hairs, independently of the effluent analysed. For the genotoxicity test with micronuclei, the plants exposed to raw wastes, to sludge, and to effluent of the biodigester have presented higher rates of chromosomal damages (micronuclei), with significant differences in relation to the control group and other effluent of the waste treatment system (p≤0.05). The association between the chemical parameters and the genotoxicity data have shown that the variables COD and TKN have presented significant correlation (p≤0.05) with the number of mutagenic events in the tetrads.

  1. Radioactive materials released from nuclear power plants. Annual report, 1982. Volume 3

    International Nuclear Information System (INIS)

    Tichler, J.; Norden, K.

    1986-02-01

    Releases of radioactive materials in airborne and liquid effluents from commercial light water reactors during 1982 have been compiled and reported. Data on solid waste shipments as well as selected operating information have been included. This report supplements earlier annual reports issued by the former Atomic Energy Commission and the Nuclear Regulatory Commission. The 1982 release data are summarized in tabular form. Data covering specific radionuclides are summarized

  2. Control verification radioactive effluent discharges to the environment

    International Nuclear Information System (INIS)

    Alvarez, D.E.; Czerniczyniec, M.A.; Amado, V.A.; Curti, A.R.; Lee Gonzáles, H.M.

    2015-01-01

    The National Law of Nuclear Activity No. 24,804 establishes that the Nuclear Regulatory Authority (ARN) will be responsible for the function of regulation and control of nuclear activity, grant, suspend and revoke licenses, permits or authorizations and to issue regulatory standards on radiation and nuclear safety. According to the latter the ARN has issued a set of rules that make up the regulatory framework for nuclear activity. This includes the standards that determine the radiological criteria for controlling the release of radioactive effluents which were established to protect members of the public. In the process of licensing a facility, the ARN determines the authorized discharge of gaseous and liquid effluents which must comply with the installation values. These annual values are understood as an operating restriction (OR) and arise from the activity of each relevant radionuclide present in the discharge. For this is taken as a reference the level of optimized discharge considering an appropriate margin of flexibility to ensure public protection without interfering with the operation of the installation. This paper presents the results of the review of the above criteria and methodology for calculating the RO adopted by the RNA present. [es

  3. en tres sistemas agroforestales

    Directory of Open Access Journals (Sweden)

    Javier Monge Meza

    2006-01-01

    Full Text Available Se estudió el desarrollo inicial (30 meses del duraznillo (Prunus annularis en tres sistemas agroforestales: duraznillo-maíz (Zea mays, duraznillomenta (Satureja viminea y duraznillo-naranjilla (Solanum quitoense, en un sitio en la zona de vida Bosque muy húmedo Montano Bajo, en Costa Rica. Se utilizaron cuatro parcelas de cada sistema agroforestal, con una densidad de 722 árboles/ ha, y un sistema de siembra de árboles en forma de triángulo equilátero, entre los que se intercaló el componente agrícola respectivo de cada sistema agroforestal. La altura media alcanzada por los árboles de duraznillo fue de 226,2, 221,4 y 164,3 cm, para el sistema agroforestal duraznillo-maíz, duraznillo- menta y duraznillo-naranjilla, respectivamente. En cuanto a los volúmenes, éstos variaron entre 0,58 y 1,30 m3/ha. Hubo una diferencia significativa en altura media entre el sistema agroforestal duraznillo-maíz y duraznillo-menta con respecto al de duraznillo-naranjilla. No hubo diferencias con respecto al volumen entre los sistemas de producción

  4. Order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche; Arrete du 10 janvier 2003 autorisant l'Agence nationale pour la gestion des dechets radioactifs a poursuivre les rejets d'effluents gazeux et liquides pour l'exploitation du centre de stockage de dechets radioactifs de la Manche

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-01-01

    This document, took out from the Official Journal, is the law text relative to the order of the 10 january 2003 authorizing the national agency for the radioactive wastes management to follow the gaseous and liquid effluents release for the exploitation of the radioactive wastes storage center of the Manche. (A.L.B.)

  5. Assessment of uranium release to the environment from a disabled uranium mine in Brazil.

    Science.gov (United States)

    Pereira, Wagner de Souza; Kelecom, Alphonse Germaine Albert Charles; da Silva, Ademir Xavier; do Carmo, Alessander Sá; Py Júnior, Delcy de Azavedo

    2018-08-01

    The Ore Treatment Unit (in Portuguese Unidade de Tratamento de Minérios - UTM) located in Caldas, MG, Brazil is a disabled uranium mine. Environmental conditions generate acid drainage leaching metals and radionuclides from the waste rock pile. This drainage is treated to remove the heavy metals and radionuclides, before allowing the release of the effluent to the environment. To validate the treatment, samples of the released effluents were collected at the interface of the installation with the environment. Sampling was carried out from 2010 to 2015, and the activity concentration (AC, in Bq·l -1 ) of uranium in the liquid effluent was analyzed by arzenazo UV-Vis spectrophotometry of the soluble and particulate fractions, and of the sum of both fractions. Descriptive statistics, Z test and Pearson R 2 correlation among the fractions were performed. Then, the data were organized by year and both ANOVA and Tukey test were carried out to group the means by magnitude of AC. The annual mean ranged from 0.02 Bq·l -1 in 2015 to 0.11 Bq·l -1 in 2010. The soluble fraction showed a higher AC mean when compared to the mean of the particulate fraction and no correlation of the data could be observed. Concerning the magnitude of the release, the ANOVA associated with the Tukey test, identified three groups of annual means (AC 2010 > AC 2011  = AC 2012  = AC 2013  = AC 2014  > AC 2015 ). The mean values of uranium release at the interface installation-environment checking point (point 014) were within the Authorized Annual Limit (AAL) set by the regulator (0.2 Bq·l -1 ) indicating compliance of treatment with the licensing established for the unit. Finally, the data showed a decreasing tendency of U release. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Role of SSNTD technique in three-step method for total assay of alpha activity in air effluents

    International Nuclear Information System (INIS)

    Kolekar, R.V.; Joshi, V.B.; Bhanti, D.P.; Bhagwat, A.M.

    2000-01-01

    In the present work, low levels of alpha activity in air effluents were estimated. Currently this essay involves collection of effluent samples and assaying them for the release using ZnS(Ag) based scintillation counter (background=1 cpm). Any activity below 1 cpm (net) therefore goes unreported. Air samples showing activity -6 Bq/m 3 (3.73x10 -17 Ci/m 3 ) to 36.41x10 -6 Bq/m 3 (9.84x10 -16 Ci/m 3 ) for samples studied over twelve months period. The three step procedure helps to measure total activity without significant burden on SSNTD technique thereby improving the acceptability of the methodology. (author)

  7. Effluent treatment for nuclear thermal propulsion ground testing

    Science.gov (United States)

    Shipers, Larry R.

    1993-01-01

    The objectives are to define treatment functions, review concept options, discuss PIPET effluent treatment system (ETS), and outline future activities. The topics covered include the following: reactor exhaust; effluent treatment functions; effluent treatment categories; effluent treatment options; concept evaluation; PIPETS ETS envelope; PIPET effluent treatment concept; and future activities.

  8. Measurement and characterization of fission products released from LWR fuel

    International Nuclear Information System (INIS)

    Osborne, M.F.; Collins, J.L.; Lorenz, R.A.; Norwood, K.S.; Strain, R.V.

    1984-01-01

    Samples of commercial LWR fuel have been heated under simulated accident conditions to determine the extent and the chemical forms of fission product release. Of the five tests discussed, the fractional releases of Kr, I, and Cs varied from proportional 2% at 1400 0 C to >50% at 2000 0 C; much smaller fractions of Ru, Ag, Sb, and Te were measured in some tests. The major chemical forms in the effluent appeared to include CsI, CsOH, Sb, Te, and Ag. (orig./HP)

  9. Supercritical water oxidation test bed effluent treatment study

    International Nuclear Information System (INIS)

    Barnes, C.M.

    1994-04-01

    This report presents effluent treatment options for a 50 h Supercritical Water Test Unit. Effluent compositions are calculated for eight simulated waste streams, using different assumed cases. Variations in effluent composition with different reactor designs and operating schemes are discussed. Requirements for final effluent compositions are briefly reviewed. A comparison is made of two general schemes. The first is one in which the effluent is cooled and effluent treatment is primarily done in the liquid phase. In the second scheme, most treatment is performed with the effluent in the gas phase. Several unit operations are also discussed, including neutralization, mercury removal, and evaporation

  10. Utilization of ultraviolet radiation in effluent disinfestation of domestic waste treatment systems; Utilizacao da radiacao ultravioleta na desinfeccao de efluentes de sistemas de tratamento de esgotos domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, P.R.R. [Companhia de Tecnologia de Saneamento Ambiental, Sao Paulo, SP (Brazil); Andrade e Silva, L.G. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1995-12-31

    Ultraviolet radiation disinfection of Upflow Anaerobic Sludge Biodigestor (UASB) and UASB with aerated lagoon pos-treatment effluents is possible to be reached utilizing a single low pressure mercury lamp arc (15 W nominal power) in a shell tube flow through reactor (1.2 L useful volume). Fecal coliforms, total coliforms and colifages were used as microbiological parameters. For fecal coliforms, about 3 logarithmic units (log. un.) was removed from UASB with aerated lagoon pos-treatment effluent and 4 log. un. from UASB effluent with 7 and 30 seconds of hydraulic retention time, respectively. Good empirical correlations were obtained between microbiological parameters and hydraulic retention times. (author). 4 refs, 1 fig, 3 tabs.

  11. Decision no 2010-DC-0182 by the Nuclear Safety Authority on the 18. of May 2010 specifying the limits of releases in the environment of liquid and gaseous effluents of civil base nuclear installations no 46, no 74 and no 100 operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan (Loir-et-Cher department)

    International Nuclear Information System (INIS)

    2010-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of civil base nuclear installations operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan. Commented tables in appendix present the limits for different radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other alpha, beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  12. sistemas

    Directory of Open Access Journals (Sweden)

    Diego Alejandro Muñoz Gaviria

    2006-01-01

    Full Text Available El texto presentado a continuación, plantea en términos generales las principales posturas conceptuales del sociólogo alemán Niklas Luhmann sobre las ideas de Max Weber y su teoría de la acción social, y de Talcott Parsons y sus planteamientos en torno a la teoría de los sistemas sociales. Al final del escrito se hace especial énfasis en el rol protagónico que para Luhmann tienen las ciencias sociales y humanas en la autorreferencia del sistema social.

  13. Sistema de seguridad en redes locales utilizando sistemas multiagentes distribuidos. Net-Mass

    Directory of Open Access Journals (Sweden)

    Daniel Horfan Álvarez

    2005-01-01

    Full Text Available La seguridad en las redes de datos es uno de los elementos neurálgicos dentro de una organización, ya que requiere de diferentes estrategias de protección para salvaguardar puntos vulnerables, y de la coordinación y distribución de esfuerzos para cercar todas las posibles formas de ataques informáticos. En este artículo se propone un sistema multiagente distribuido como herramienta de protección para redes con diferentes sistemas operativos y susceptibilidad de diversos ataques.El sistema propuesto está conformado por un grupo de agentes autónomos heterogéneos con características particulares en cuanto a sus estrategias de detección de intrusos y protección de los sistemas primordiales de la red, se tiene planeado que estos agentes basen sus decisiones en la aplicación de diferentes técnicas de inteligencia artificial como heurística de sistemas expertos, algoritmos evolutivos y redes neuronales.

  14. Statistical evaluation of effluent monitoring data for the 200 Area Treated Effluent Disposal Facility

    International Nuclear Information System (INIS)

    Chou, C.J.; Johnson, V.G.

    2000-01-01

    The 200 Area Treated Effluent Disposal Facility (TEDF) consists of a pair of infiltration basins that receive wastewater originating from the 200 West and 200 East Areas of the Hanford Site. TEDF has been in operation since 1995 and is regulated by State Waste Discharge Permit ST 4502 (Ecology 1995) under the authority of Chapter 90.48 Revised Code of Washington (RCW) and Washington Administrative Code (WAC) Chapter 173-216. The permit stipulates monitoring requirements for effluent (or end-of-pipe) discharges and groundwater monitoring for TEDF. Groundwater monitoring began in 1992 prior to TEDF construction. Routine effluent monitoring in accordance with the permit requirements began in late April 1995 when the facility began operations. The State Waste Discharge Permit ST 4502 included a special permit condition (S.6). This condition specified a statistical study of the variability of permitted constituents in the effluent from TEDF during its first year of operation. The study was designed to (1) demonstrate compliance with the waste discharge permit; (2) determine the variability of all constituents in the effluent that have enforcement limits, early warning values, and monitoring requirements (WHC 1995); and (3) determine if concentrations of permitted constituents vary with season. Additional and more frequent sampling was conducted for the effluent variability study. Statistical evaluation results were provided in Chou and Johnson (1996). Parts of the original first year sampling and analysis plan (WHC 1995) were continued with routine monitoring required up to the present time

  15. Best Available Technology (BAT) guidance for radiological liquid effluents at US Department of Energy Facilities

    International Nuclear Information System (INIS)

    Wallo, A. III; Peterson, H.T. Jr.; Ikenberry, T.A.; Baker, R.E.

    1993-01-01

    The US Department of Energy (DOE), in DOE Order 5400.5 (1990), directs operators of DOE facilities to apply the Best Available Technology (BAT) to control radiological liquid effluents from these facilities when specific conditions are present. DOE has published interim guidance to assist facility operators in knowing when a BAT analysis is needed and how such an analysis should be performed and documented. The purpose of the guidance is to provide a uniform basis in determining BAT throughout DOE and to assist in evaluating BAT determinations during programmatic audits. The BAT analysis process involves characterizing the effluent source; identifying and selecting candidate control technologies; evaluating the potential environmental, operational, resource, and economic impacts of the control technologies; developing an evaluation matrix for comparing the technologies; selecting the BAT; and documenting the evaluation process. The BAT analysis process provides a basis for consistent evaluation of liquid effluent releases, yet allows an individual site or facility the flexibility to address site-specific issues or concerns in the most appropriate manner

  16. Decision no 2010-DC-0189 by the Nuclear Safety Authority on the 7. of July 2010 specifying to Electricite de France-Societe Anonyme (EDF-SA) instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents for the operation of the Flamanville 1 (IBN n 108), Flamanville 2 (INB n 109) and Flamanville 3 (INB n 167) reactors

    International Nuclear Information System (INIS)

    2010-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from three nuclear reactors. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control, the control of the environment (air, soil, surface and underground water, sampling point implantation), the information of authorities and of population

  17. Order of the 15. of September 2010 approving the decision no 2010-DC-0188 by the Nuclear Safety Authority on the 7. of July 2010 specifying to Electricite de France-Societe Anonyme (EDF-SA) the limits of releases in the environment of liquid and gaseous effluents for the operation of Flamanville 1 (INB n 108), Flamanville 2 (INB n 109) and Flamanville 3 (INB n 167) reactors

    International Nuclear Information System (INIS)

    2010-01-01

    This legal publication contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents by the three Flamanville nuclear reactors operated by Electricite de France-Societe Anonyme (EDF-SA). Tables present the limits for different gaseous and liquid radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine hydrate, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  18. Release of volatile and semi-volatile toxicants during house fires.

    Science.gov (United States)

    Hewitt, Fiona; Christou, Antonis; Dickens, Kathryn; Walker, Richard; Stec, Anna A

    2017-04-01

    Qualitative results are presented from analysis of volatile and semi-volatile organic compounds (VOCs/SVOCs) obtained through sampling of gaseous effluent and condensed particulates during a series of experimental house fires conducted in a real house. Particular emphasis is given to the 16 polycyclic aromatic hydrocarbons (PAHs) listed by the Environmental Protection Agency due to their potentially carcinogenic effects. The initial fuel packages were either cooking oil or a single sofa; these were burned both alone, and in furnished surroundings. Experiments were performed at different ventilation conditions. Qualitative Gas Chromatography-Mass Spectrometry (GC-MS) analysis found VOC/SVOC releases in the developing stages of the fires, and benzo(a)pyrene - the most carcinogenic PAH - was found in at least one sampling interval in the majority of fires. A number of phosphorus fire retardants were detected, in both the gaseous effluent and particulates, from fires where the initial fuel source was a sofa. Their release during the fire is significant as they pose toxicological concerns separate from those presented by the PAHs. Copyright © 2016. Published by Elsevier Ltd.

  19. Decision no 2010-DC-0183 by the Nuclear Safety Authority on the 18. of May 2010 specifying instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installations no 46, no 74 and no 100 operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan (Loir-et-Cher department)

    International Nuclear Information System (INIS)

    2010-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from some specific base nuclear installations. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control, and the information of authorities and of population

  20. Decision no 2009-DC-0155 of the 15. of September 2009 by the Nuclear Safety Authority specifying the limits of releases in the environment of liquid and gaseous effluents of base nuclear installations n. 18, 35, 40, 49, 50, 72, 77 and 101 operated by the Atomic Energy Commissariat (CEA) in its Saclay Centre, located on the districts of Saclay, Saint-Aubin and Villiers-le-Bacle (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    This document contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of base nuclear installations of the Saclay Centre operated by the Atomic Energy Commissariat (CEA). Tables present the limits for different radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other alpha, beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (HCl, HF, NOx, CO, and so on), as well as limits for thermal releases

  1. Flow proportional sampling of low level liquid effluent

    International Nuclear Information System (INIS)

    Colley, D.; Jenkins, R.

    1989-01-01

    A flow proportional sampler for use on low level radioactive liquid effluent has been developed for installation on all CEGB nuclear power stations. The sampler, operates by drawing effluent continuously from the main effluent pipeline, through a sampler loop and returning it to the pipeline. The effluent in this loop is sampled by taking small, frequent aliquots using a linear acting shuttle valve. The frequency of operation of this valve is controlled by a flowmeter installed in the effluent line; sampling rate being directly proportional to effluent flowrate. (author)

  2. Occurrences and fate of selected human antibiotics in influents and effluents of sewage treatment plant and effluent-receiving river Yamuna in Delhi (India).

    Science.gov (United States)

    Mutiyar, Pravin K; Mittal, Atul K

    2014-01-01

    Antibiotics consumption has increased worldwide, and their residues are frequently reported in aquatic environments. It is believed that antibiotics reach aquatic water bodies through sewage. Medicine consumed for healthcare practices are often released into sewage, and after sewage treatment plant, it reaches the receiving water bodies of lakes or rivers. In the present study, we determined the fate of some commonly used antibiotics in a sewage treatment plant (STP) located in Delhi and the environmental concentration of these antibiotics in the Yamuna River, which receives the sewage and industrial effluent of Delhi. There are many reports on antibiotics occurrences in STP and river water worldwide, but monitoring data from the Indian subcontinent is sparse. Samples were taken from a STP and from six sampling sites on the Yamuna River. Several antibiotics were tested for using offline solid-phase extraction followed by high-performance liquid chromatography equipped with photodiode array analysis. Recoveries varied from 25.5-108.8 %. Ampicillin had the maximum concentration in wastewater influents (104.2 ± 98.11 μg l(-1)) and effluents (12.68 ± 8.38 μg l(-1)). The fluoroquinolones and cephalosporins had the lower concentrations. Treatment efficiencies varied between 55 and 99 %. Significant amounts of antibiotics were discharged in effluents and were detected in the receiving water body. The concentration of antibiotics in the Yamuna River varied from not detected to 13.75 μg l(-1) (ampicillin) for the compounds investigated.

  3. Radioactive release data from Canadian nuclear generating stations 1872-1987

    International Nuclear Information System (INIS)

    1989-03-01

    All nuclear generating stations emit small quantities of radioactive effluent both into the atmosphere and in the form of liquid effluent, into the adjoining water body, be it river, lake or sea. The purpose of this document is to report on the magnitude of these emissions for each nuclear generating station in Canada and to indicate how these emissions compare with the relevant limitations imposed by the Atomic Energy Control Board as part of its regulatory and licensing program. This report incorporates histograms indicating the annual releases of tritium in air, noble gases, iodine-131, airborne particulates, tritium in water and waterborne gross beta activity for each nuclear generating station. In addition, for Pickering NGS 'A', annual released of carbon-14 are depicted for the years 1986 and 1987. In each case the emission data are compared to the Derived Emission Limit (DEL) in order that the data may be placed in perspective. At present, only Pickering NGS 'A' is required to monitor and report carbon-14 emissions. Environmental monitoring for C-14 is conducted around the Bruce site to determine the environmental impact of its emission and whether effluent monitoring will be necessary in future years. Three nuclear generating stations have been permanently taken out of service during the last few years (Gentilly NGS-1, Douglas Point NGS and NPD NGS). Some small emissions from these sites do still occur, however, due to decontamination and decommissioning operations. (11 tabs., 26 figs.)

  4. The occurrence of emerging trace organic chemicals in wastewater effluents in Saudi Arabia

    KAUST Repository

    Alidina, Mazahirali

    2014-04-01

    Emerging trace organic chemicals (TOrCs) released into the environment via discharge of wastewater effluents have been detected in rivers and lakes worldwide, raising concerns due to their potential persistence, toxicity and bioaccumulation. This study provides the first reconnaissance of TOrC occurrence in wastewater effluents within Saudi Arabia. Four wastewater treatment plants (WWTPs 1-4) located in Western Saudi Arabia were sampled hourly over twelve-hour periods, for a total of six sampling events. All samples were analyzed for a wide range of TOrC encompassing pharmaceuticals, personal care products and household chemicals. Treatment and capacities of the plants varied from non-nitrifying to full biological nutrient removal providing a representative cross section of different types of plants operational within the country. A comparison of TOrC occurrence in effluents in Saudi Arabia with respective effluent qualities in the United States revealed similar levels for most TOrC. Overall, the occurrence of TOrC was higher at two of the plants. The higher TOrC concentrations at WWTP 1 are likely due to the non-nitrifying biological treatment process. The unique TOrC occurrence observed in the WWTP 3 effluent was unlike any other plant and was attributed to the influence of a large number of international visitors in its sewershed. The occurrence of TOrC in this plant was not expected to be representative of the occurrence elsewhere in the country. Bimodal diurnal variation expected for a range of TOrC was not observed, though some hourly variation in TOrC loading was noted for WWTP 3. Since water reclamation and reuse have received increasing interest in Saudi Arabia within the last few years, results from this study provide a good foundation in deciding whether advanced treatment is necessary to attenuate TOrC deemed to be of concern in effluents, or if natural treatment such as managed aquifer recharge provides sufficient protection to public health. © 2014

  5. Release of synthetic microplastic plastic fibres from domestic washing machines: Effects of fabric type and washing conditions.

    Science.gov (United States)

    Napper, Imogen E; Thompson, Richard C

    2016-11-15

    Washing clothes made from synthetic materials has been identified as a potentially important source of microscopic fibres to the environment. This study examined the release of fibres from polyester, polyester-cotton blend and acrylic fabrics. These fabrics were laundered under various conditions of temperature, detergent and conditioner. Fibres from waste effluent were examined and the mass, abundance and fibre size compared between treatments. Average fibre size ranged between 11.9 and 17.7μm in diameter, and 5.0 and 7.8mm in length. Polyester-cotton fabric consistently shed significantly fewer fibres than either polyester or acrylic. However, fibre release varied according to wash treatment with various complex interactions. We estimate over 700,000 fibres could be released from an average 6kg wash load of acrylic fabric. As fibres have been reported in effluent from sewage treatment plants, our data indicates fibres released by washing of clothing could be an important source of microplastics to aquatic habitats. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Monitoring of the release of gaseous and aerosol-bound radioactive materials. Pt. 2

    International Nuclear Information System (INIS)

    1992-01-01

    KTA 1503 contains requirements on technical installations and supplementary organizational measures considered necessary in order to monitor the release of gaseous and aerosol-bound radioactive materials. It consists of part 1: Monitoring of the release of radioactive materials together with stack gas during normal operation; part 2: Monitoring of the release of radioactive materials together with stack gas in the event of incidents; part 3: Monitoring of radioactive materials not released together with stack gas. The concept on which this rule is based is to ensure that in the case of incidents during which the result of effluent monitoring remains meaningful, such monitoring can be reliably performed. (orig./HSCH) [de

  7. 40 CFR 417.82 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.82 Effluent limitations guidelines representing the...

  8. 40 CFR 415.342 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... SOURCE CATEGORY Chrome Pigments Production Subcategory § 415.342 Effluent limitations guidelines... available (BPT): Subpart AH—Chrome Pigments Pollutant or pollutant property BPT effluent limitations Maximum...

  9. 40 CFR 407.67 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Fruits Subcategory § 407.67 Effluent limitations guidelines...

  10. 40 CFR 407.77 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY Canned and Preserved Vegetables Subcategory § 407.77 Effluent limitations guidelines...

  11. 40 CFR 406.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.73 Section 406.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY....73 Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

  12. Animal alternatives for whole effluent toxicity testing ...

    Science.gov (United States)

    Since the 1940s, effluent toxicity testing has been utilized to varying degrees in many countries to assess potential ecological impacts and assist in determining necessary treatment options for environmental protection. However, it was only in the early 1980’s that toxicity based effluent assessments and subsequent discharge controls became globally important, when it was recognized that physical and chemical measurements alone did not protect the environment from potential impacts. Consequently, various strategies using different toxicity tests, whole effluent assessment techniques (incorporating bioaccumulation potential and persistence) plus supporting analytical tools have been developed over 30 years of practice. Numerous workshops and meetings have focused on effluent risk assessment through ASTM, SETAC, OSPAR, UK competent authorities, and EU specific country rules. Concurrent with this drive to improve effluent quality using toxicity tests, interest in reducing animal use has risen. The Health and Environmental Sciences Institute (HESI) organized and facilitated an international workshop in March 2016 to evaluate strategies for concepts, tools, and effluent assessments and update the toolbox of for effluent testing methods. The workshop objectives were to identify opportunities to use a suite of strategies for effluents, and to identify opportunities to reduce the reliance on animal tests and to determine barriers to implementation of new methodologie

  13. Liquid effluent processing group. Activity details 1963

    International Nuclear Information System (INIS)

    1964-08-01

    This report first gives a quantitative overview of volumes of effluents of high activity, medium activity and low activity which passed through the department for effluent processing. It also makes the distinction between the shape or type of container of these effluents. A table indicates their origin and another indicates their destination. The β and α decontamination rates are determined, and the assessment of stored aqueous and organic effluents on the 31 December 1963 is given. The next part proposes an assessment of laboratory activities: control operations (input controls, control of processed effluent before discarding), controls related to processing (processing types, radiochemical and chemical dosing performed on effluent mixes before processing). Tables indicate the characteristics of medium activity effluents collected in 1963, the results of high activity liquid analysis, and Beryllium dosing results. A summary of ALEA processing, a table of the characteristics of stored oils and solvents are given. The third part reports data related to transport activities, and various works performed in the Saclay plant to improve exploitation conditions and results

  14. 40 CFR 417.83 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Soaps Subcategory § 417.83 Effluent limitations guidelines representing the degree of...

  15. 40 CFR 415.647 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.647 Effluent limitations guidelines... subject to this subpart and producing cadmium pigments must achieve the following effluent limitations...

  16. 40 CFR 415.643 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... CATEGORY Cadmium Pigments and Salts Production Subcategory § 415.643 Effluent limitations guidelines... subject to this subpart and producing cadmium pigments must achieve the following effluent limitations...

  17. 40 CFR 406.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.32 Section 406.32 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.32 Effluent limitations guidelines representing the degree of effluent reduction...

  18. 40 CFR 406.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.42 Section 406.42 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.42 Effluent limitations guidelines representing the degree of effluent reduction...

  19. 40 CFR 406.52 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.52 Section 406.52 Protection of Environment ENVIRONMENTAL PROTECTION... Milling Subcategory § 406.52 Effluent limitations guidelines representing the degree of effluent reduction...

  20. 40 CFR 406.12 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... technology currently available. 406.12 Section 406.12 Protection of Environment ENVIRONMENTAL PROTECTION... Subcategory § 406.12 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  1. 40 CFR 406.33 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.33 Section 406.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.33 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  2. 40 CFR 406.53 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 406.53 Section 406.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.53 Effluent limitations guidelines representing the degree of effluent reduction attainable...

  3. 40 CFR 424.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... economically achievable. 424.73 Section 424.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Chromium Subcategory § 424.73 Effluent limitations guidelines representing the degree of effluent reduction...

  4. Sistemas biodegradáveis contendo acetato de prednisolona para administração orbitária Biodegradable systems containing prednisolone acetate for orbital administration

    Directory of Open Access Journals (Sweden)

    Ricardo Martins Duarte Byrro

    2009-08-01

    Full Text Available OBJETIVO: O presente estudo objetivou o desenvolvimento e a avaliação de um sistema biodegradável de liberação de fármacos com característica de liberação prolongada, destinado à administração orbitária de acetato de prednisolona (AP. MÉTODOS: O sistema desenvolvido, na forma de microesferas (MEs de poli-e-caprolactona (PCL contendo o AP, foi obtido pelo método de evaporação de solvente. As MEs foram caracterizadas por microscopia eletrônica de varredura (MEV, calorimetria diferencial exploratória (DSC, avaliação do teor de encapsulação e pelo perfil de liberação in vitro. O perfil de liberação in vivo foi avaliado em coelhos após administração peribulbar de uma suspensão aquosa das MEs. A biocompatibilidade local do sistema foi verificada por meio de análise histopatológica da região de implantação. RESULTADOS: Após obtenção das MEs, a análise morfológica por MEV mostrou a viabilidade do método de obtenção do sistema. O teor de AP encapsulado foi de 43 ± 7% e pode ser considerado bastante satisfatório. A caracterização do sistema por DSC, além de confirmar a sua estabilidade, não indicou a existência de interação entre o fármaco e o polímero. O estudo de liberação in vitro indicou que o sistema apresenta perfil de liberação prolongada. O estudo in vivo confirmou o perfil de liberação prolongado do AP a partir das MEs, sugerindo, também, a viabilidade do sistema devido à ausência de toxicidade local. CONCLUSÃO: O conjunto dos resultados obtidos neste trabalho é relevante e credencia o sistema desenvolvido como uma possível alternativa ao tratamento de orbitopatias inflamatórias.PURPOSE: The present study aimed to evaluate an injectable extended-release formulation of prednisolone acetate (PA for orbital administration. METHODS: Microspheres (MEs of poly-e-caprolactone (PCL containing PA were developed by the method of solvent evaporation. The MEs obtained were characterized by

  5. Waste analysis plan for the 200 area effluent treatment facility and liquid effluent retention facility

    International Nuclear Information System (INIS)

    Ballantyne, N.A.

    1995-01-01

    This waste analysis plan (WAP) has been prepared for startup of the 200 Area Effluent Treatment Facility (ETF) and operation of the Liquid Effluent Retention Facility (LERF), which are located on the Hanford Facility, Richland, Washington. This WAP documents the methods used to obtain and analyze representative samples of dangerous waste managed in these units, and of the nondangerous treated effluent that is discharged to the State-Approved Land Disposal System (SALDS). Groundwater Monitoring at the SALDS will be addressed in a separate plan

  6. Evaluation guide for the radiological impact study of a basic nuclear installation (BNI) as a support for the authorization application of releases

    International Nuclear Information System (INIS)

    Chartier, Mr.; Despres, A.; Supervil, S.; Conte, D.; Hubert, P.; Oudiz, A.; Champion, D.

    2002-10-01

    At the time of a licence application of effluent releases and water pumping of basic nuclear facilities (BNF), the operator of the installation must in particular provide a radiological impact study of the radioactive effluent releases coming from the installation on the environment and on public health. An impact study of the radioactive releases represents technical and conditional specifications. It was for this reason that the French Safety Authority (ASN then DSIN) and the Directorate-General of Health Services (DGS) requested IRSN (then IPSN), in April 1999, to develop a guide facilitating the review of such a study, as well for the services implied in the examination of the licence applications, as for all the concerned parties in this field. The objective of the guide is to take into account the regulatory context which underlies the development of the impact studies (decree no. 95-540 of May 4, 1995, modified by the decree no. 2002-460 of April 4, 2002, and the Euratom guideline 96/29 of May 13, 1996, known as 'the basic standard guideline', accompanied by its transposition texts in French law). In this precise context, the guide proposes to assess the radiological impact study of a BNF from three different angles: - the description and the quantification of the produced effluents, by taking account of the triggering processes, of the different processing measures and of the procedures to optimise the reduction of the produced effluents; - the estimate of the dosimetric impact of the planned releases on the population, taking into account the environmental characteristics of the installation; - the definition of the conditions to monitor the releases and the environment. This guide provides a general condition logical framework adaptable to any particular situation met

  7. 40 CFR 440.23 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ...) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore Subcategory... discharged in mine drainage from mines producing bauxite ores shall not exceed: Effluent characteristic...

  8. 40 CFR 440.22 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORE MINING AND DRESSING POINT SOURCE CATEGORY Aluminum Ore... pollutants discharged in mine drainage from mines producing bauxite ores shall not exceed: Effluent...

  9. 40 CFR 414.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 414.73 Section 414.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 414.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  10. 40 CFR 410.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 410.73 Section 410.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... § 410.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  11. Continuously tritium monitoring of the pipe of liquid effluents at the Cea Cadarache; Controle en continu du tritium de la conduite des effluents liquides du CEA Cadarache

    Energy Technology Data Exchange (ETDEWEB)

    Pira, Y

    2004-07-01

    This report is oriented toward the radiation protection of environment that is an essential component of radiation protection. It is necessary to detect any solid, liquid or gaseous abnormal release and to find its origin. The present study bears on a detection instrument in continuously to find tritium in liquid effluents of the Cea Cadarache. After having study the functioning principle of this device, an evaluation of its performances has been realised ( back noise, yield, detection limit) and to a checking in real conditions of utilization. (N.C.)

  12. Radiation treatment of sewage effluent, (2)

    International Nuclear Information System (INIS)

    Sawai, Teruko; Sekiguchi, Masayuki; Sawai, Takeshi; Shimokawa, Toshinari; Tanabe, Hiroko

    1991-01-01

    The water demand of the past several years has increased rapidly. Recycling of municipal waste water is an effective mean of coping with the water shortage in Tokyo. We studied the radiation treatment method of further purification of the effluent from sewage treatment plants. By gamma irradiation the refractory organic substances in the effluent were decomposed and the COD values decreased with increasing dose. The high molecular weight components in the effluent were degraded to lower molecular weight substances and were decomposed finally to carbon dioxide. In this paper we studied on the fading color and the reducing of order of sewage effluent. (author)

  13. Releases of radioactivity at the Savannah River Plant, 1954-1980

    Energy Technology Data Exchange (ETDEWEB)

    Ashley, C.; Zeigler, C. C.; Culp, P. A.

    1982-01-01

    This report contains summaries of releases of radioactivity to onsite seepage basins and to plant effluents for each year since plant startup (1954 through 1980). Releases for the years 1954 through 1959 were reassessed in 1974 and assigned release values for specific long-lived radionuclides. These long-lived radionuclides (half-lives greater than 1 year) are the only radionuclides included for the years 1954 through 1970. Since 1970 all detectable radionuclides have been included. Measured migration o radionuclides from F-, H-, and K-Area seepage basins and desorption of /sup 137/Cs from the Four Mile Creek stream bed are included in Summary B of this report. Summaries of monthly releases for 1979 and 1980 and total SRP releases by radionuclide in three categories: liquid to seepage basins, liquid to streams, and atmospheric are also included. Monthly releases for 1979 are included because the 1979 issue of this report was not published. All 1979 data are included in this report.

  14. Influence of marine sediments in the distribution of the main radionuclides of the effluent from the nuclear power plant Almirante Alvaro Alberto (Unit 1)

    International Nuclear Information System (INIS)

    Brugnara, Miriam

    1977-01-01

    This study aimed to: 1) Characterize bottom sediments of the Angra dos Reis region, in the dispersion area of the effluent of the central Almirante Nuclear Alvaro Alberto, Unit 1. 2) Determining the adsorption capacity of these sediments to the long half-life and mean radionuclides to be released in the reactor effluent in a higher concentration. 3) Estimate the fraction of the different studied radionuclides that will be immobilized in sediments. 4) Identify critical radionuclides available for food chain

  15. Facility effluent monitoring plan for WESF

    International Nuclear Information System (INIS)

    SIMMONS, F.M.

    1999-01-01

    The FEMP for the Waste Encapsulation and Storage Facility (WESF) provides sufficient information on the WESF effluent characteristics and the efferent monitoring systems so that a compliance assessment against applicable requirements may be performed. Radioactive and hazardous material source terms are related to specific effluent streams that are in turn, related to discharge points and, finally are compared to the effluent monitoring system capability

  16. Filtration device for active effluents

    International Nuclear Information System (INIS)

    Guerin, M.; Meunier, G.

    1994-01-01

    Among the various techniques relating to solid/liquid separations, filtration is currently utilized for treating radioactive effluents. After testing different equipments on various simulated effluents, the Valduc Center has decided to substitute a monoplate filter for a rotative diatomite precoated filter

  17. 40 CFR 420.73 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... achievable (BAT). 420.73 Section 420.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Subcategory § 420.73 Effluent limitations representing the degree of effluent reduction attainable by the...

  18. Characterisation of potential aquaculture pond effluents, and ...

    African Journals Online (AJOL)

    Conventional treatment of effluents from these small-scale, low-volume operations, which discharge relatively dilute effluents infrequently, might not be cost-effective. Keywords: aquaculture–environment interaction, earthen ponds, effluent characterisation, K-means clustering, t ilapia, water quality. African Journal of Aquatic ...

  19. The effluent problem in a plutonium production centre; Probleme des effluents d'un centre de production de plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Galley, R; Cantel, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The first part of the report is devoted to generalities: the geographical situation of the Marcoule Centre, the sources of radio-active effluent, methods of treating this effluent. In the second part the authors gives a detailed description of the various installations in the Radio-active Effluent Treatment Station at the Marcoule Centre, and outline the conditions governing the rejection of treated effluent into the Rhone. A few lines are given to comparisons between the results obtained from the use of these installations up till may 1959 and the expected results published by the same authors at the Brussels Conference (1956). In conclusion the authors lay down some of the essential principles, applicable to the study of new installations. (author) [French] La premiere partie du rapport est consacree a quelques generalites: situation geographique du Centre de Marcoule, provenance des effluents radioactifs, methodes de traitement de ces effluents. Dans la seconde partie, les auteurs presentent une description detaillee des diverses installations de la Station de Traitement des Effluents radioactifs du Centre de Marcoule et precisent les conditions de rejet dans le Rhone des effluents radioactifs traites. Quelques lignes sont consacrees aux comparaisons entre les resultats de l'exploitation des installations jusqu'en mai 1959 et les previsions publiees par les memes auteurs a l'occasion de la Conference de Bruxelles (1956). En conclusion, les auteurs donnent quelques principes essentiels, applicables a l'etude de nouvelles installations. (auteur)

  20. Distribution of antibiotic resistance in the effluents of ten municipal wastewater treatment plants in China and the effect of treatment processes.

    Science.gov (United States)

    Ben, Weiwei; Wang, Jian; Cao, Rukun; Yang, Min; Zhang, Yu; Qiang, Zhimin

    2017-04-01

    Municipal wastewater treatment plant (WWTP) effluents represent an important contamination source of antibiotic resistance, threatening the ecological safety of receiving environments. In this study, the release of antibiotic resistance to sulfonamides and tetracyclines in the effluents of ten WWTPs in China was investigated. Results indicate that the concentrations of antibiotic-resistant bacteria (ARB) and antibiotic resistance genes (ARGs) ranged from 1.1 × 10 1 to 8.9 × 10 3  CFU mL -1 and 3.6 × 10 1 (tetW) to 5.4 × 10 6 (tetX) copies mL -1 , respectively. There were insignificant correlations of the concentrations of ARB and ARGs with those of corresponding antibiotics. Strong correlations were observed between the total concentrations of tetracycline resistance genes and sulfonamide resistance genes, and both of which were significantly correlated with intI1 concentrations. Statistical analysis of the effluent ARG concentrations in different WWTPs revealed an important role of disinfection in eliminating antibiotic resistance. The release rates of ARB and ARGs through the effluents of ten WWTPs ranged from 5.9 × 10 12 to 4.8 × 10 15  CFU d -1 and 6.4 × 10 12 (tetW) to 1.7 × 10 18 (sul1) copies d -1 , respectively. This study helps the effective assessment and scientific management of ecological risks induced by antibiotic resistance discharged from WWTPs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Methanization of industrial liquid effluents; Methanisation des effluents industriels liquides

    Energy Technology Data Exchange (ETDEWEB)

    Frederic, S.; Lugardon, A. [Societe Naskeo Environnement, 92 - Levallois-Perret (France)

    2007-09-15

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  2. Transplants of aquatic mosses as biomonitors of metals released by a mine effluent

    International Nuclear Information System (INIS)

    Figueira, Rui; Ribeiro, Teresa

    2005-01-01

    Transplants of the aquatic moss Fontinalis antipyretica Hedw. were used to assess the contamination of an industrial effluent discharge on a river located in south Portugal. The sampling program was run for 2 years, using a newly developed transplant device in ten stations, and the elements analysed were Cu, Zn, Pb, Fe, Ni, Ca, K, and Mg. An increase of water contamination by Cu, Zn was detected, and to a lesser extent, Pb. The increase was verified in the extra and intracellular moss fraction, especially for soluble Cu in the first 4 km after the discharge point, and also for particulate metal at the first station after the discharge. The effects of metal contamination could be related to changes in the intracellular concentrations of Mg, indicating possible stress effects. - Effects of metal contamination could be related to changes in intracellular concentrations of Mg

  3. Estimation of Near-Field and Far-Field Dilutions for Site Selection of Effluent Outfall in a Coastal Region - A Case Study

    Digital Repository Service at National Institute of Oceanography (India)

    Naidu, V.S.

    . The effluent would move along the coast, and chances of reaching to the estuary are remote. Rise of the biological oxygen demand concentration to 2.9 mg/L above ambient is predicted at the release site. The water quality of Damanganga estuary would be restored...

  4. Order of the 17. of June 2010 approving the decision no 2010-DC-0182 by the Nuclear Safety Authority on the 18. of May 2010 specifying the limits of releases in the environment of liquid and gaseous effluents of civil base nuclear installations no 46, 74 and 100 operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan (Loir-et-Cher department)

    International Nuclear Information System (INIS)

    2010-01-01

    This legal publication contains references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion) at the root of this specification of limits related to releases in the environment of liquid and gaseous effluents of civil base nuclear installations operated by Electricite de France-Societe Anonyme (EDF-SA) on the district of Saint-Laurent-Nouan. Tables present the limits for different radioactive emissions (carbon 14, hydrogen 3, iodine, radioactive rare earths, and other alpha, beta and gamma emitters) from these different installations, but also the maximum admitted concentrations for gaseous chemical effluents (boric acid, hydrazine, morpholine, phosphates, nitrates, various metals, and so on). The limits for thermal releases are also specified

  5. Sistemas roboticos teleoperados

    Directory of Open Access Journals (Sweden)

    Alexander Ceron Correa

    2005-01-01

    Full Text Available En el presente artículo se realiza una revisión general sobre los sistemas robóticos teleoperados, su estructura, componentes principales, clasificación, tipos de sensores, sistemas de locomoción y aplicaciones; como ejemplo se mencionan algunos trabajos realizados Colombia y en el mundo

  6. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    International Nuclear Information System (INIS)

    Coenenberg, J.G.

    1997-01-01

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, 'operating' treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  7. Hanford Facility dangerous waste permit application, liquid effluent retention facility and 200 area effluent treatment facility

    Energy Technology Data Exchange (ETDEWEB)

    Coenenberg, J.G.

    1997-08-15

    The Hanford Facility Dangerous Waste Permit Application is considered to 10 be a single application organized into a General Information Portion (document 11 number DOE/RL-91-28) and a Unit-Specific Portion. The scope of the 12 Unit-Specific Portion is limited to Part B permit application documentation 13 submitted for individual, `operating` treatment, storage, and/or disposal 14 units, such as the Liquid Effluent Retention Facility and 200 Area Effluent 15 Treatment Facility (this document, DOE/RL-97-03). 16 17 Both the General Information and Unit-Specific portions of the Hanford 18 Facility Dangerous Waste Permit Application address the content of the Part B 19 permit application guidance prepared by the Washington State Department of 20 Ecology (Ecology 1987 and 1996) and the U.S. Environmental Protection Agency 21 (40 Code of Federal Regulations 270), with additional information needs 22 defined by the Hazardous and Solid Waste Amendments and revisions of 23 Washington Administrative Code 173-303. For ease of reference, the Washington 24 State Department of Ecology alpha-numeric section identifiers from the permit 25 application guidance documentation (Ecology 1996) follow, in brackets, the 26 chapter headings and subheadings. A checklist indicating where information is 27 contained in the Liquid Effluent Retention Facility and 200 Area Effluent 28 Treatment Facility permit application documentation, in relation to the 29 Washington State Department of Ecology guidance, is located in the Contents 30 Section. 31 32 Documentation contained in the General Information Portion is broader in 33 nature and could be used by multiple treatment, storage, and/or disposal units 34 (e.g., the glossary provided in the General Information Portion). Wherever 35 appropriate, the Liquid Effluent Retention Facility and 200 Area Effluent 36 Treatment Facility permit application documentation makes cross-reference to 37 the General Information Portion, rather than duplicating

  8. The treatment of effluents

    International Nuclear Information System (INIS)

    Wormser, G.; Rodier, J.; Robien, E. de; Fernandez, N.

    1964-01-01

    For several years the French Atomic Energy Commission has been studying with interest problems presented by radio-active effluents. Since high activities have not yet received a definite solution we will deal only, in this paper, with the achievements and research concerning low and medium activity effluents. In the field of the achievements, we may mention the various effluent treatment stations which have been built in France; a brief list will be given together with an outline of their main new features. Thus in particular the latest treatment stations put into operation (Grenoble, Fontenay-aux-Roses, Cadarache) will be presented. From all these recent achievements three subjects will be dealt with in more detail. 1 - The workshop for treating with bitumen the sludge obtained after concentration of radionuclides. 2 - The workshop for treating radioactive solid waste by incineration. 3 - A unit for concentrating radio-active liquid effluents by evaporation. In the field of research, several topics have been undertaken, a list will be given. In most cases the research concerns the concentration of radionuclides with a view to a practical and low cost storage, a concentration involving an efficient decontamination of the aqueous liquids in the best possible economic conditions. For improving the treatments leading to the concentration of nuclides, our research has naturally been concerned with perfecting the treatments used in France: coprecipitation and evaporation. In our work we have taken into account in particular two conditions laid down in the French Centres. 1 - A very strict sorting out of the effluents at their source in order to limit in each category the volume of liquid to be dealt with. 2 - The necessity for a very complete decontamination due to the high population density in our country. In the last past we present two original methods for treating liquid effluents. 1 - The use of ion-exchange resins for liquids containing relatively many salts. The

  9. Measurement and characterization of fission products released from LWR fuel

    International Nuclear Information System (INIS)

    Osborne, M.F.; Collins, J.L.; Lorenz, R.A.; Norwood, K.S.; Strain, R.V.

    1984-01-01

    Samples of commercial LWR fuel have been heated under simulated accident conditions to determine the extent and the chemical forms of fission product release. This project was sponsored by the USNRC under a broad program of reactor safety studies. Of the five tests discussed, the fractional releases of Kr, I, and Cs varied from approx. 2% at 1400 0 C to >50% at 2000 0 C; much smaller fractions of Ru, Ag, Sb, and Te were measured in some tests. The major chemical forms in the effluent appeared to include CsI, CsOH, Sb, Te, and Ag

  10. Assessment of reproductive effects in largemouth bass (Micropterus salmoides) exposed to bleached/unbleached kraft mill effluents.

    Science.gov (United States)

    Sepúlveda, M S; Ruessler, D S; Denslow, N D; Holm, S E; Schoeb, T R; Gross, T S

    2001-11-01

    This study evaluated the potential effects of different concentrations of bleached/unbleached kraft mill effluent (B/UKME) on several reproductive endpoints in adult largemouth bass (Micropterus salmoides). The kraft mill studied produces a 50/50 mix of bleached/unbleached market pulp with an estimated release of 36 million gal of effluent/day. Bleaching sequences were C90d10EopHDp and CEHD for softwood (pines) and hardwoods (mainly tupelo, gums, magnolia, and water oaks), respectively. Bass were exposed to different effluent concentrations (0 [controls, exposed to well water], 10, 20, 40, or 80%) for either 28 or 56 days. At the end of each exposure period, fish were euthanized, gonads collected for histological evaluation and determination of gonadosomatic index (GSI), and plasma was analyzed for 17beta-estradiol, 11-ketotestosterone, and vitellogenin (VTG). Largemouth bass exposed to B/UKME responded with changes at the biochemical level (decline in sex steroids in both sexes and VTG in females) that were usually translated into tissue/organ-level responses (declines in GSI in both sexes and in ovarian development in females). Although most of these responses occurred after exposing fish to 40% B/UKME concentrations or greater, some were observed after exposures to 20% B/UKME. These threshold concentrations fall within the 60% average yearly concentration of effluent that exists in the stream near the point of discharge (Rice Creek), but are above the <10% effluent concentration present in the St. Johns River. The chemical(s) responsible for such changes as well as their mode(s) of action remain unknown at this time.

  11. Situation 2002: release monitoring and surveillance of environment of Cea centers

    International Nuclear Information System (INIS)

    2003-07-01

    This publication renders an account of the situation of the releases of liquid and gaseous radioactive effluents, for the year 2002, as well as the radioactivity levels measured in the vicinity of Cea centers through the systematic surveillance of atmosphere, waters, vegetation and milk. An analysis on five years allows to follow their evolution. (N.C.)

  12. Nutrient removal from swine lagoon effluent by duckweed

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, B.A.; Cheng, J.; Classen, J.; Stomp, A.M.

    2000-04-01

    Three duckweed geographic isolates were grown on varying concentrations of swine lagoon effluent in a greenhouse to determine their ability to remove nutrients from the effluent. Duckweed biomass was harvested every other day over a 12-day period. Duckweed biomass production, nutrient loss from the swine lagoon effluent, and nutrient content of duckweed biomass were used to identify effluent concentrations/geographic isolate combinations that are effective in terms of nutrient utilization from swine lagoon effluent and production of healthy duckweed biomass. When Lemna minor geographic isolate 8627 was grown on 50% swine lagoon effluent, respective losses of TKN, NH{sub 3}-N, TP, OPO{sub 4}-P, TOC, K, Cu, and Zn were 83, 100, 49, 31, 68, 21, 28 and 67%.

  13. PFOS and PFOA in influents, effluents, and biosolids of Chinese wastewater treatment plants and effluent-receiving marine environments

    International Nuclear Information System (INIS)

    Chen Hong; Zhang Can; Han Jianbo; Yu Yixuan; Zhang Peng

    2012-01-01

    Concentrations of perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA) in influents, effluents and sludges were investigated by analyzing the samples from twelve wastewater treatment plants (WWTPs) in China. The highest concentrations of PFOS and PFOA in influents were found to occur in municipal and industrial WWTPs, respectively. Relative to PFOS and PFOA concentrations in influents, elevated concentrations were observed in effluents from WWTPs applying anaerobic–anoxic–oxic wastewater treatment process. Importantly, application of previously reported organic carbon normalized partition coefficients (K OC ) derived from sediment-based sorption experiments appear to underestimate the PFOS and PFOA levels in biosolids quantified in the current study. PFOS and PFOA levels in effluents were found to be approximately 27 and 2 times higher than those detected in the effluent-receiving seawater, respectively. However, their levels in this area of seawater haven't exceeded the provisional short-term health advisories in drinking water issued by U.S. EPA yet. - Highlights: ► Levels of PFOS and PFOA in influents, effluents and sludge from Chinese WWTPs were examined. ► Municipal sewage was the main source for PFOS in Chinese WWTPs, while industrial sewage for PFOA. ► PFOS and PFOA concentrations in effluents were much higher than those in receiving seawater. - Levels of PFOS and PFOA in influent, effluent and sludge samples from Chinese WWTPs were examined and found much higher than those in receiving seawater.

  14. Study of the hydrodynamic circulation and transport of radionuclides in the Ilha Grande Bay -RJ

    International Nuclear Information System (INIS)

    Franklin, Mariza Ramalho

    2001-01-01

    The Almirante Alvaro Alberto Nuclear Center (CNAAA), located at the city of Rio de Janeiro and the liquid effluents are released into the Ilha Grande Bay (BIG). The objective of this work was to simulate mathematically the dispersion of 3 H and 137 Cs present in the liquid effluents that are routinely released into the environment, and in this way contribute to the improvement of the radiological impact assessment associated to these releases. The hydrodynamic circulation pattern of the bay and the transport of radionuclides were simulated by means of numerical modeling techniques by the computational system SisBAHIA (Sistema Base Hidrodinâmica e Ambiental). The results indicate that the local circulation pattern is mainly driven by the propagation of the tidal wave, and is characterized by low current velocities of about 0.1 m.s -1 . The wind stress (normal or extreme ones ) over the free surface does not alter the local circulation pattern significantly. The effluents are released in a rate of about 120 m 3 .s. -1 . As a result, the local hydrodynamics is markedly altered by means of the formation of a huge vortices close to the release area. According to the annual amount of the released radionuclides predicted in the Nuclear Licensing Document, and considering a continuous release it could be predicted that the radionuclide plume would present a low mobility, with most of the activity concentration amount being restricted close to the source. The activity concentration distribution reach the transportation steady state by the end of the 51 st day of simulation. A conservative behavior of both radionuclides in the water column was assumed in the performed simulation. (author)

  15. Effluent Guidelines

    Science.gov (United States)

    Effluent guidelines are national standards for wastewater discharges to surface waters and municipal sewage treatment plants. We issue the regulations for industrial categories based on the performance of treatment and control technologies.

  16. Distribution of 137Cs Radionuclide in Industrial Wastes Effluents of Gresik, East Java, Indonesia

    Directory of Open Access Journals (Sweden)

    Muslim

    2015-04-01

    Full Text Available The distribution of anthropogenic radionuclides 137Cs was measured from industrial waste effluent of Gresik to Gresik Sea in east Java, Indonesia. The activity of 37Cs detected at all stations was much lower than in northeast Japan both before and after NPP Fukushima accident. This indicated that in Gresik industrials waste did not consist of 137Cs. The lowest activity 137Cs occurred at the station nearest to the industrial waste effluent that contained some particle ions that were able to scavenge 137Cs and then precipate this radionuclide. Furthermore, the greatest 137Cs occured at the station that has high current speeds that stirred up sediment to release 137Cs in seawater as a secondary source. The lowest salinity did not effect on the activity of 137Cs even though the lowest salinity and activity 137Cs occured at the same station

  17. Cytogenotoxicity evaluation of two industrial effluents using Allium ...

    African Journals Online (AJOL)

    ISHIOMA

    textile effluent was 4.5 times more toxic than the paint effluent. ... Key words: Genotoxicity, paint, textile, industrial effluents, Allium cepa, mutation, pollution, chromosomal .... concentration of a chemical producing 50% of the total effect).

  18. Efeito de sistemas de produção e doses de adubo de liberação lenta no estado nutricional de porta-enxerto cítrico The effect of production systems and doses of controlled-release fertilizer on the nutritional status of citrus rootstock

    Directory of Open Access Journals (Sweden)

    Luiz Augusto Lopes Serrano

    2004-12-01

    Full Text Available O sistema de produção do porta-enxerto, antes da repicagem, pode modificar o sistema radicular das plântulas e a resposta destas à adubação. Assim, o objetivo desse trabalho foi avaliar os efeitos de três sistemas de produção do limoeiro 'Cravo' e de cinco doses de um adubo de liberação lenta, aplicados após a repicagem, sobre o estado nutricional do limoeiro 'Cravo' no ponto de enxertia. O experimento foi conduzido, sob viveiro telado, em esquema fatorial 3 x 5, com sete repetições e uma planta por parcela. Os sistemas de produção do porta-enxerto foram: 1- produção em tubetes e citrovasos preenchidos com substrato comercial composto por casca de pínus; 2- produção em tubetes e citrovasos preenchidos com substrato composto por bagaço de cana-de-açúcar + torta de filtro (3:2; v:v, e 3- produção em blocos prensados e citrovasos constituídos pela prensagem do substrato utilizado no sistema 2. As doses de adubo de liberação lenta, fórmula NPK 14-14-14, foram: 5; 10; 15; 20 e 25 g/planta. O sistema de produção do porta-enxerto, antes da repicagem, influenciou na resposta do limoeiro 'Cravo' à adubação após a repicagem. No ponto de enxertia, as plantas cultivadas no sistema de blocos prensados apresentaram menores teores foliares de P, K e Fe em relação às plantas provenientes de tubetes, mas apresentaram maiores médias de crescimento (peso seco do sistema radicular, peso seco de folhas, peso seco de caules e diâmetro do caule. Plantas cultivadas no sistema 1 apresentaram sintomas foliares de deficiência de Fe, enquanto as plantas dos outros dois sistemas apresentaram sintomas foliares de deficiência de Mg.The production system of citrus rootstock before the transplanting can modify the seedlings root system and the response of these to fertilization. The objective of this experiment was to evaluate the effects of three production systems of 'Rangpur' lime tree and five doses of a controlled-release

  19. Regulación neuroendocrina del sistema inmune

    OpenAIRE

    Caballero Hernández, Diana; Tamez Guerra, Reyes S.; Rodríguez Padilla, Cristina; Tamez Guerra, Patricia; Weber, Richard J.; Gómez Flores, Ricardo

    2001-01-01

    El sistema inmune recibe señales del sistema nervioso central (cerebro) vía el sistema nervioso autónomo y el sistema endocrino. El sistema inmune, a su vez, envía información al cerebro vía citocinas. Este sistema de retroalimentación es vital para el funcionamiento adecuado del organismo en situaciones normales, y en aquellas en las que la homeostasis se ve perturbada, como en casos de estrés, consumo de drogas (terapéuticas o de abuso), enfermedades infecciosas y...

  20. modelling effluent assimila modelling effluent assimilat modelling

    African Journals Online (AJOL)

    eobe

    G EFFLUENT ASSIMILATIVE CAPACITY OF IKPOBA RIVE. BENIN CITY, NIGERIA ... l purposes to communities rse such as ... treat in order for it to meet the aforeme of the communities. It is therefore i ..... Substituting and integrating yields the following equations ..... Purification Potentials of Small Tropical Urban. Stream: A ...

  1. Release monitoring and environmental surveillance of Cea centers. Assessment and regulation and method 1999

    International Nuclear Information System (INIS)

    2000-01-01

    The quality of the natural environment around the centers of the Commissariat a l Energie Atomique is an important point of its safety policy. The environmental protection is based on the control of risks coming from research and development activities of its installations. It aims to reduce as low as possible, the impact of its activities on man and his environment. This publication develops the sampling and measurement methods that are made on effluents and in environment, according to the radionuclides characteristics, that are present. It gives also the regulation that applied to the effluents monitoring. The results of radioactive effluents releases (liquid and gaseous) and the surveillance of environment around cea centers is given in the 'Bilan 1999' publication. An analysis of these results on the 1995-1999 period allows to follow their evolution. (N.C.)

  2. 200 Area Liquid Effluent Facilities -- Quality assurance program plan

    International Nuclear Information System (INIS)

    Fernandez, L.

    1995-01-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance and management controls used by the 200 Area Liquid Effluent Facilities (LEF) to perform its activities in accordance with DOE Order 5700.6C. The 200 Area LEF consists of the following facilities: Effluent Treatment Facility (ETF); Treated Effluent Disposal Facility (TEDF); Liquid Effluent Retention facility (LERF); and Truck Loading Facility -- (Project W291). The intent is to ensure that all activities such as collection of effluents, treatment, concentration of secondary wastes, verification, sampling and disposal of treated effluents and solids related with the LEF operations, conform to established requirements

  3. 40 CFR 417.163 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS SOAP AND DETERGENT MANUFACTURING POINT SOURCE CATEGORY Manufacture of Liquid Detergents Subcategory § 417.163 Effluent limitations guidelines representing the degree... subpart after application of the best available technology economically achievable: (a) For normal liquid...

  4. 40 CFR 428.62 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations guidelines... technology currently available. 428.62 Section 428.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium...

  5. 40 CFR 428.63 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Effluent limitations guidelines... economically achievable. 428.63 Section 428.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS RUBBER MANUFACTURING POINT SOURCE CATEGORY Medium-Sized General...

  6. Effluent monitoring: Its purpose and value

    International Nuclear Information System (INIS)

    Schoen, A.A.

    1978-01-01

    The purpose of effluent monitoring is described in terms of the primary objectives, the most important of which is to verify that the facility is functioning as it was designed and that the waste treatment and effluent control systems are performing as planned and expected. The object of a monitoring programme should be periodically re-examined to ensure that the programme serves a contemporary purpose. The value of the effluent monitoring programme is determined by the extent to which users of the monitoring data, i.e. the operator, the regulating authorities and the public, accept the result as indicating that the plant is operating safely, and in an environmentally acceptable manner. The credibility of the monitoring results is therefore the most important factor determining the value of an effluent monitoring programme. (author)

  7. Assessment of effluent turbidity in mesophilic and thermophilic sludge reactors - origin of effluent colloidal material

    NARCIS (Netherlands)

    Vogelaar, J.C.T.; Lier, van J.B.; Klapwijk, B.; Vries, M.C.; Lettinga, G.

    2002-01-01

    Two lab-scale plug flow activated sludge reactors were run in parallel for 4 months at 30 and 55°C. Research focussed on: (1) COD (chemical oxygen demand) removal, (2) effluent turbidity at both temperatures, (3) the origin of effluent colloidal material and (4) the possible role of protozoa on

  8. Desalination of effluent using fin type solar still

    Energy Technology Data Exchange (ETDEWEB)

    Velmurugan, V. [Department of Mechanical Engineering, Infant Jesus College of Engineering, Thoothukudi, Tamil Nadu 628 851 (India); Deenadayalan, C.K.; Vinod, H.; Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai, Tamil Nadu 625 015 (India)

    2008-11-15

    In this work, an attempt is made to produce potable water from industrial effluents. An ordinary basin type solar still integrated with fins at the basin plate is used for experimentation. Since industrial effluent is used as feed, before this still, an effluent settling tank is provided to get clarified effluent. This effluent settling tank is fabricated with three chambers, consists of pebble, coal and sand for settling the impurities and removing the bacteria in the effluents. Sponges, pebbles, black rubber and sand are used in the fin type single basin solar still for enhancing the yield. Results show that the productivity increases considerably due to this modification. A theoretical analysis is also carried out which, closely converges with experimental results. The economic analysis proved that the approximate payback period of such kinds of still is 1 year. (author)

  9. Management of metal arising from an Italian Nuclear Facility: techniques for clearance and unconditional release - Management of metals resulting from an Italian nuclear facility: techniques for clearance and unconditional release

    International Nuclear Information System (INIS)

    Baldassarre, Leonardo; Varasano, Giovanni; Bruno, Salvatore Gaetano

    2014-01-01

    The start of the decommissioning of nuclear plants in Italy lead to an appreciable increase in the volume of metal materials that will need to radiological characterization for the unconditional release. The nuclear fuel reprocessing plant ITREC, located in Rotondella (MT) in the south of Italy, is currently undergoing safety maintenance. As part of these activities was necessary the replacement of approximately 5000 m of radioactive liquid effluents discharge's pipeline. The entire pipeline is undergoing treatment within a small Waste Management Facility suitably equipped for the cutting, the separation of non-metallic residue and decontamination. 100% of the pipe portions are characterized through measurements of gross-beta and high resolution gamma spectrometry in order to verify the clearance of materials. The target levels of surface activity and specific activity, prescribed by the National Regulatory Authority, is verified through measurement activities implemented according to specific MQOs defined for the specific process. Activities, subject to National Regulatory Authority control, allow the unconditional release of metallic materials originated from the removal of the radioactive liquid effluents discharge's pipeline in nuclear fuel reprocessing plant ITREC managed by SOGIN SpA. The methodology described provides a good example of management, treatment and decontamination of metallic materials for unconditional release. (authors)

  10. Sistemas de gestión ambiental normalizados

    OpenAIRE

    Fronti de García, Luisa; Pahlen, Ricardo José María; D’Onofrio, Paula Alejandra

    2004-01-01

    La contabilidad ambiental presupone la existencia de un sistema de gestión ambiental. Dentro del sistema integral de la organización, el sistema de gestión ambiental permite la obtención de información oportuna y segura. Podríamos definir el sistema de gestión ambiental de un ente como el conjunto de medidas destinadas a prevenir el impacto negativo de las actividades del ente sobre el medio ambiente. El sistema de gestión ambiental (SGA) es aquella parte del sistema de gestión total que incl...

  11. Potential Water Retention Capacity as a Factor in Silage Effluent Control: Experiments with High Moisture By-product Feedstuffs.

    Science.gov (United States)

    Razak, Okine Abdul; Masaaki, Hanada; Yimamu, Aibibula; Meiji, Okamoto

    2012-04-01

    The role of moisture absorptive capacity of pre-silage material and its relationship with silage effluent in high moisture by-product feedstuffs (HMBF) is assessed. The term water retention capacity which is sometimes used in explaining the rate of effluent control in ensilage may be inadequate, since it accounts exclusively for the capacity of an absorbent incorporated into a pre-silage material prior to ensiling, without consideration to how much the pre-silage material can release. A new terminology, 'potential water retention capacity' (PWRC), which attempts to address this shortcoming, is proposed. Data were pooled from a series of experiments conducted separately over a period of five years using laboratory silos with four categories of agro by-products (n = 27) with differing moisture contents (highest 96.9%, lowest 78.1% in fresh matter, respectively), and their silages (n = 81). These were from a vegetable source (Daikon, Raphanus sativus), a root tuber source (potato pulp), a fruit source (apple pomace) and a cereal source (brewer's grain), respectively. The pre-silage materials were adjusted with dry in-silo absorbents consisting wheat straw, wheat or rice bran, beet pulp and bean stalks. The pooled mean for the moisture contents of all pre-silage materials was 78.3% (±10.3). Silage effluent decreased (p<0.01), with increase in PWRC of pre-silage material. The theoretical moisture content and PWRC of pre-silage material necessary to stem effluent flow completely in HMBF silage was 69.1% and 82.9 g/100 g in fresh matter, respectively. The high correlation (r = 0.76) between PWRC of ensiled material and silage effluent indicated that the latter is an important factor in silage-effluent relationship.

  12. 40 CFR 424.13 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.13 Section 424.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces With Wet Air Pollution Control Devices Subcategory § 424.13 Effluent limitations guidelines...

  13. 40 CFR 424.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.43 Section 424.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Carbide Furnaces With Wet Air Pollution Control Devices Subcategory § 424.43 Effluent limitations...

  14. 40 CFR 429.163 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best available technology economically... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... application of the best available technology economically achievable (BAT). Except as provided in 40 CFR 125...

  15. 40 CFR 429.171 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... best practicable control technology currently available (BPT). Except as provided in 40 CFR 125.30...

  16. 40 CFR 429.173 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best available technology economically... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... best available technology economically achievable (BAT). Except as provided in 40 CFR 125.30 through...

  17. 40 CFR 429.161 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Science.gov (United States)

    2010-07-01

    ... degree of effluent reduction attainable by the application of the best practicable control technology... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS TIMBER PRODUCTS PROCESSING POINT SOURCE CATEGORY Wood Furniture... application of the best practicable control technology currently available (BPT). Except as provided in 40 CFR...

  18. 40 CFR 426.123 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GLASS MANUFACTURING POINT SOURCE CATEGORY Incandescent Lamp... technology economically achievable: (a) [Reserved] (b) Any manufacturing plant which frosts incandescent lamp... characteristic Effluent limitations Maximum for any 1 day Average of daily values for 30 consecutive days shall...

  19. Treatment of effluent at the Saclay Centre d'Etudes Nucleaires (1960); Le traitement des effluents du Centre d'Etudes Nucleaires de Saclay (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The Centre d'Etudes Nucleaires at Saclay possesses several installations from which liquid radioactive effluent is rejected, and it has thus been found necessary to construct a station for the purification of radioactive liquids and to settle various chemical, analytical and technological problems. This report describes, in the following order: - the disposal possibilities at the Centre d'Etudes Nucleaires, Saclay, - the effluents produced at the centre, - the set-up for collecting effluent, - treatment of the effluent, - results of these treatments. (author) [French] La presence, au Centre d'Etudes Nucleaires de Saclay, de plusieurs installations susceptibles de rejeter des effluents liquides radioactifs a necessite la construction d'une station d'epuration d'eaux radioactives et la mise au point de differents problemes chimiques, analytiques et technologiques. Dans ce rapport, nous exposerons successivement: - les possibilites de rejet du Centre d'Etudes Nucleaires de Saclay, - les effluents du centre, - le dispositif de collecte des effluents, - le traitement de ces effluents, - les resultats de ces traitements. (auteur)

  20. The potential use of treated brewery effluent as a water and nutrient source in irrigated crop production

    Directory of Open Access Journals (Sweden)

    Richard P. Taylor

    2018-06-01

    Full Text Available Brewery effluent (BE needs to be treated before it can be released into the environment, reused or used in down-stream activities. This study demonstrated that anaerobic digestion (AD followed by treatment in an integrated tertiary effluent treatment system transformed BE into a suitable solution for crop irrigation. Brewery effluent can be used to improve crop yields: Cabbage (Brassica oleracea cv. Star 3301, grew significantly larger when irrigated with post-AD, post-primary-facultative-pond (PFP effluent, compared with those irrigated with post-constructed-wetland (CW effluent or tap water only (p < 0.0001. However, cabbage yield when grown using BE was 13% lower than that irrigated with a nutrient-solution and fresh water; the electrical conductivity of BE (3019.05 ± 48.72 µs/cm2 may have been responsible for this. Post-CW and post-high-rate-algal-pond (HRAP BE was least suitable due to their higher conductivity and lower nutrient concentration. After three months, soils irrigated with post-AD and post-PFP BE had a significantly higher sodium concentration and sodium adsorption ratio (3919 ± 94.77 & 8.18 ± 0.17 mg/kg than soil irrigated with a commercial nutrient-solution (920.58 ± 27.46 & 2.20 ± 0.05 mg/kg. However, this was not accompanied by a deterioration in the soil's hydro-physical properties, nor a change in the metabolic community structure of the soil. The benefits of developing this nutrient and water resource could contribute to cost-reductions at the brewery, more efficient water, nutrient and energy management, and job creation. Future studies should investigate methods to reduce the build-up of salt in the soil when treated BE is used to irrigate crops. Keywords: Wastewater irrigation, Nutrient recovery, Agriculture, Brewery effluent

  1. Pre-treatment and membrane ultrafiltration using treated palm oil mill effluent (POME

    Directory of Open Access Journals (Sweden)

    Wong Pui Wah

    2002-11-01

    Full Text Available Treatment of palm oil mill effluent (POME has always been a topic of research in Malaysia. This effluent that is extremely rich in organic content needs to be properly treated to minimize environmental hazards before it is released into watercourses. The common practice for treating POME in Malaysia involves a combination of aerobic and anaerobic methods. The purpose of tertiary treatment is to allow the treated water to be reused in the mill operations for other purposes such as feed water. The proposed treatment will also ensure the industry to meet a more stringent discharge standard in terms of the BOD, COD and nitrogen values. In this study membrane ultrafiltration is used as the tertiary treatment method. Before the actual membrane operation was conducted, the samples were pre-treated using three separate method namely filtration, centrifugation and coagulation. It was found that the combination of filtrationultrafiltration treatment POME produced the best-treated sample quality in terms of pollutant contents elimination, namely % BOD, % COD and % nitrogen removal.

  2. SISTEMA COMBINADO DE FLOTAÇÃO POR AR DISSOLVIDO E FILTRAÇÃO ADSORTIVA EM ZEÓLITA PARA TRATAMENTO DE EFLUENTE DE REATOR UASB

    Directory of Open Access Journals (Sweden)

    Bruno Oliveira Freitas

    2016-06-01

    Full Text Available RESUMO: Dentre as soluções existentes para efetuar o tratamento de esgoto, o reator anaeróbio do tipo UASB é largamente utilizado no Brasil, porém esta tecnologia apresenta problemas em atender aos limites estabelecidos pela legislação brasileira para lançamento de efluente em termos de nitrogênio amoniacal, fósforo e matéria orgânica, necessitando de pós-tratamento. Diante do potencial para remoção de matéria orgânica e sólidos suspensos pela flotação e da eficiência que a zeólita apresenta na remoção de amônia, a floto-filtração-adsortiva em zeólita pode ser uma promissora alternativa para tratamento deste efluente. Sendo assim, o presente trabalho visou avaliar a eficiência de um sistema de flotação associado à filtração-adsortiva, utilizando zeólita como meio filtrante, para pós-tratamento de efluente de reator UASB. Para tal, foram realizados ensaios de coagulação/floculação, flotação e filtração-adsortiva com um floteste adaptado com filtros adsorventes, utilizando efluente de reator anaeróbio do tipo UASB. Os resultados obtidos neste estudo atenderam aos padrões estabelecidos pela legislação brasileira para lançamento de efluentes em corpos d’água, alcançando 100 % de remoção de nitrogênio amoniacal, permitindo que esse efluente possa ser aproveitado para reuso. Desse modo, o sistema de flotação com a filtração-adsortiva utilizando zeólita como meio filtrante mostrou-se eficiente na remoção de todos os poluentes avaliados. Esta pesquisa teve como principal contribuição a avaliação de alternativa promissora para pós-tratamento de efluente de reator UASB buscando atender as exigências da legislação brasileira e melhorar da qualidade dos efluentes sanitários. ABSTRACT: Among the existing solutions to sewage treatment, the UASB reactor is widely used in Brazil, but this technology has problem to attend the limits established by Brazilian law for discharging of effluent

  3. 40 CFR 424.23 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. 424.23 Section 424.23 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Furnaces and Other Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.23 Effluent...

  4. 40 CFR 406.17 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology. 406.17 Section 406.17 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 406.17 Effluent limitations guidelines representing the degree of effluent reduction attainable by the...] Effective Date Note: Section 406.17 was indefinitely suspended at 45 FR 45582, July 7, 1980. ...

  5. Facility effluent monitoring plan for the B plant

    International Nuclear Information System (INIS)

    Lesser, J.E.

    1994-09-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plant assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated every three years

  6. Primary effluent filtration for coastal discharges

    Energy Technology Data Exchange (ETDEWEB)

    Cooper-Smith, G.D. [Yorkshire Water Services, Huddersfield (United Kingdom); Rundle, H. [The Capital Controls Group, Nottingham (United Kingdom)

    1998-12-31

    The use of a Tetra Deep Bed filter demonstration unit to treat primary effluent (Primary Effluent Filtration, PEF) was investigated. PEF proved capable of achieving the UWWTD primary standard, even when the primary stage performs poorly, but is not a cost-effective alternative to chemically assisted settlement. Results demonstrated that using a 1.5 to 2.2 mm grade medium, a filtration rate of 5 m/h, three backwashes a day and dosing 40 mg/l of PAXXL60 (a polyaluminium silicte) an average effluent quality of 20 mg/l BOD and 15 mgl/l total solid could be achieved. UV disinfection produced an effluent which complied with the Bathing Water Directive imperative requirement. A high enterovirus kill was also achieved. However, considerable additional work would be required before PEF could be considered suitable for full-scale applications. (orig.)

  7. Facility effluent monitoring plan for 242-A evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1995-02-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, as a minimum, every three years

  8. 40 CFR 458.43 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... this paragraph, which may be discharged from the carbon black lamp process by a point source subject to... Lamp Process Subcategory § 458.43 Effluent limitations guidelines representing the degree of effluent... achievable: There shall be no discharge of process waste water pollutants to navigable waters. ...

  9. Facility effluent monitoring plan for 242-A Evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1993-03-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility effluent Monitoring Plans, WHC-EP-0438-1**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  10. Radiological impact of atmospheric releases from a coal-fired power station

    International Nuclear Information System (INIS)

    Aigueperse, J.; Chalabreysse, J.; Coulon, R.; Grauby, A.; Uzzan, G.

    1982-01-01

    As the first stage of a study carried out under contract with the Commission of the European Communities for the comparative assessment of the risks to which the individuals of a regional population are exposed, the paper seeks to evaluate atmospheric releases from a coal-fired thermal power station. The station is of traditional design with an installed capacity of 415MW(e) and uses only lignite-type coal produced from a coal basin situated nearby. Gaseous effluents are released from four stacks. The area close to the station is rural in nature: there are a number of small farms, fairly abundant natural vegetation and some fairly well-populated zones with various industries. The main feature of the weather conditions is the strong prevailing winds in the optimum direction. A radiation measurement campaign involving the main 238 U and 232 Th daughter products was carried out focussing on: (1) the coal burnt in the power station; (2) the solid residues resulting from combustion (fly ash, wet ash); (3) gaseous effluents by means of direct sampling from the two release stacks. The information obtained on the releases has made it possible, with the help of dispersion and transfer models, to evaluate the atmospheric concentration of the different radionuclide released as well as their deposition and presence in the biotope in the plant vicinity. The effective dose equivalents received by persons living in the zone of maximum exposure and consuming food produced in that zone were assessed at approximately 7x10 -5 Sv.a -1 at the end of the plant's operating period. Finally, the main radionuclides were measured at a number of points near the plant with the aim of verifying the model evaluations for a particular situation. (author)

  11. Radiological impact of atmospheric releases from a coal-fired power station

    Energy Technology Data Exchange (ETDEWEB)

    Aigueperse, J; Chalabreysse, J; Coulon, R; Grauby, A [CEA Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Protection; Uzzan, G [Association EURATOM-CEA, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Protection

    1982-01-01

    As the first stage of a study carried out under contract with the Commission of the European Communities for the comparative assessment of the risks to which the individuals of a regional population are exposed, the paper seeks to evaluate atmospheric releases from a coal-fired thermal power station. The station is of traditional design with an installed capacity of 415MW(e) and uses only lignite-type coal produced from a coal basin situated nearby. Gaseous effluents are released from four stacks. The area close to the station is rural in nature: there are a number of small farms, fairly abundant natural vegetation and some fairly well-populated zones with various industries. The main feature of the weather conditions is the strong prevailing winds in the optimum direction. A radiation measurement campaign involving the main /sup 238/U and /sup 232/Th daughter products was carried out focussing on: (1) the coal burnt in the power station; (2) the solid residues resulting from combustion (fly ash, wet ash); (3) gaseous effluents by means of direct sampling from the two release stacks. The information obtained on the releases has made it possible, with the help of dispersion and transfer models, to evaluate the atmospheric concentration of the different radionuclide released as well as their deposition and presence in the biotope in the plant vicinity. The effective dose equivalents received by persons living in the zone of maximum exposure and consuming food produced in that zone were assessed at approximately 7x10/sup -5/Sv.a/sup -1/ at the end of the plant's operating period. Finally, the main radionuclides were measured at a number of points near the plant with the aim of verifying the model evaluations for a particular situation.

  12. Assessment of derived emission limits for radioactive effluents resulted from the decommissioning activities of the VVR-S nuclear research reactor

    International Nuclear Information System (INIS)

    Tuca, C.; Stochioiu, A.; Sahagia, M.; Gurau, D.; Dragusin, M.

    2015-01-01

    This paper presents complex studies on establishment of derived emission limits for potential radionuclides emitted as gaseous and liquid effluents, during the decommissioning activities (2nd and 3rd phases) of a nuclear research reactor, cooled and moderated with distilled water, type VVR-S, owned by the IFIN-HH. In the present paper there are described: the analysis methods and equipment used, the methodologies for calculating doses and the Derived Emission Limits (DEL), the experimentally measured activities of the representative radionuclides found in gaseous and liquid effluents resulted from decommissioning activities, as well as the effective derived limits of liquid and gaseous effluents, applying the calculation methodologies, specific to critical categories of exposed subjects. A constraint effective dose limit for a person from the critical group of 50 μSv/year was considered in calculations. From the comparison of the two series of values, measured released activities and DELs, there has been concluded that for the gaseous effluents they comply with the DELs, while in the case of liquid effluents they are higher and consequently they must be treated as liquid radioactive wastes. - Highlights: • The DELs for gaseous and liquid effluents in decommissioning were studied. • The impact on the environment and critical group was assessed. • Gamma-ray spectrometry was used to determine the radionuclide composition. • Based on the dosimetry models, the values of conservative DELs were calculated. • The DELs are compliant for gases, not for liquids; require the treatment as rad-waste

  13. Release of NPY in pig pancreas: Dual parasympathetic and sympathetic regulation

    International Nuclear Information System (INIS)

    Sheikh, S.P.; Holst, J.J.; Skak-Nielsen, T.; Knigge, U.; Warberg, J.; Theodorsson-Norheim, E.; Hoekfelt, T.; Lundberg, J.M.; Schwartz, T.W.

    1988-01-01

    Several lines of evidence have connected neuropeptide Y (NPY), a 36-residue polypeptide, to the sympathetic division of the autonomic nervous system. The authors studied the localization, the molecular characteristics, and the release of NPY and norepinephrine (NE) in the porcine pancreas. Immunohistochemical investigations revealed that NPY nerves around blood vessels were likely to be of adrenergic nature, whereas NPY-immunoreactive fibers close to exocrine and endocrine cells may originate from local ganglia also containing VIP (vasoactive intestinal peptide) and PHI (peptide histidine isoleucine). Electrical stimulation of the splanchnic nerve supply to the isolated perfused pig pancreas resulted in a corelease of NPY and NE into the venous effluent. Stimulation of the vagal nerves caused a sevenfold larger release of NPY without affecting the NE secretion. Characterization of the NPY immunoreactivity in the pancreatic tissue and in the venous effluent by gel filtration, high-performance liquid chromatography, and isoelectric focusing shoed that the immunoreactive NPY was indistinguishable from synthetic porcine NPY. It is concluded that, although NPY is associated with sympathetic perivascular neurons, the majority of the pancreatic NPY-containing nerve fibers are likely to belong to the parasympathetic division of the autonomic nervous system

  14. Implementação de um sistema SIP para o sistema operacional Linux

    OpenAIRE

    Davison Gonzaga da Silva

    2003-01-01

    Resumo: Este trabalho apresenta a implementação de um Sistema de VoIP usando o Protocolo SIP. Este Sistema SIP foi desenvolvido para o Linux, usando-se a linguagem C++ em conjunto com a biblioteca QT. O Sistema SIP é composto de três entidades básicas: o Terminal SIP, o Proxy e o Servidor de Registros. O Terminal SIP é a entidade responsável por estabelecer sessões SIP com outros Terminais SIP. Para o Terminal SIP, foi desenvolvida uma biblioteca de acesso à placa de áudio, que permite a modi...

  15. 40 CFR 406.27 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.27 Section 406.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 406.27 Effluent limitations guidelines representing the degree of effluent reduction attainable by the... conventional pollutants (which are defined in § 401.16) in § 406.22 of this subpart for the best practicable...

  16. 40 CFR 406.47 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.47 Section 406.47 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.47 Effluent limitations guidelines representing the degree of effluent reduction attainable... specified for conventional pollutants (which are defined in § 401.16) in § 406.42 of this subpart for the...

  17. 40 CFR 406.37 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... control technology (BCT). 406.37 Section 406.37 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Subcategory § 406.37 Effluent limitations guidelines representing the degree of effluent reduction attainable... specified for conventional pollutants (which are defined in § 401.16) in § 406.32 of this subpart for the...

  18. 40 CFR 417.153 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... operation of spray drying towers as defined above, the following values pertain: Effluent characteristic...) 1 Within the range 6.0 to 9.0. (b) For air quality restricted operation of a spray drying tower, but... Manufacture of Spray Dried Detergents Subcategory § 417.153 Effluent limitations guidelines representing the...

  19. El sistema deportivo. Amenazas y oportunidades

    Directory of Open Access Journals (Sweden)

    Javier Olivera Betrán

    2006-06-01

    Full Text Available Aplicando la teoría de sistemas de Ludwig von Bertalanffy, el deporte es un sistema. En un sistema se da un conjunto de unidades interrelacionadas de tal manera que el comportamiento de cada parte depende del estado de todas las otras, pues todas se encuentran en una estructura que las interconecta. En el enfoque sistémico, el concepto tradicional de energía es reemplazado por el de información, y el de causa-efecto por el de estructura y realimentación. El deporte es una realidad social total, por lo que participa de manera implícita y/o explícita en los procesos humanos más diversos a través de los distintos procedimientos que corresponden a nuestra organización sociocultural. El deporte se configura en estructuras de alta complejidad, las cuales están constituidas por sistemas de sistemas cuya comprensión y estudio representan un formidable reto. El estudio del deporte como sistema debe efectuarse desde la lógica estructural y sistémica a través de la cual nos permita indagar con éxito su configuración esencial, sus elementos fundamentales y el proceso de interactuación con los subsistemas que pertenecen al sistema deporte y con los otros del sistema sociocultural dominante. El deporte es un sistema dinámico que interactúa continuamente mediante un doble proceso, intrínseco a través de una constante metamorfosis entre los distintos subsistemas que lo integran y extrínseco por medio de un ajuste permanente con el contexto social, cultural y medioambiental.

  20. Systematic study of the contamination of wastewater treatment plant effluents by organic priority compounds in Almeria province (SE Spain).

    Science.gov (United States)

    Barco-Bonilla, Nieves; Romero-González, Roberto; Plaza-Bolaños, Patricia; Martínez Vidal, José L; Garrido Frenich, Antonia

    2013-03-01

    The occurrence of priority organic pollutants in wastewater (WW) effluents was evaluated in a semi-arid area, characterized by a high agricultural and tourism activity, as Almeria province (Southeastern Spain). Twelve wastewater treatment plants (WWTPs) were sampled in three campaigns during 2011, obtaining a total of 33 WW samples, monitoring 226 compounds, including pesticides, polycyclic aromatic hydrocarbons (PAHs), phenolic compounds and volatile organic compounds (VOCs). Certain banned organochlorine pesticides such as aldrin, pentachlorobenzene, o,p'-DDD and endosulfan lactone were found, and the most frequently detected pesticides were herbicides (diuron, triazines). PAHs and VOCs were also detected, noting that some of these pollutants were ubiquitous. Regarding phenolic compounds, 4-tertoctylphenol was found in all the WW samples at high concentration levels (up to 89.7 μg/L). Furthermore, it was observed that WW effluent samples were less contaminated in the second and third sampling periods, which corresponded to dry season. This evaluation revealed that despite the WW was treated in the WWTP, organic contaminants are still being detected in WW effluents and therefore they are released into the environment. Finally the risk of environmental threat due to the presence of some compounds in WWTP effluents, especially concerning 4-tertoctylphenol must be indicated. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Continuously tritium monitoring of the pipe of liquid effluents at the Cea Cadarache

    International Nuclear Information System (INIS)

    Pira, Y.

    2004-01-01

    This report is oriented toward the radiation protection of environment that is an essential component of radiation protection. It is necessary to detect any solid, liquid or gaseous abnormal release and to find its origin. The present study bears on a detection instrument in continuously to find tritium in liquid effluents of the Cea Cadarache. After having study the functioning principle of this device, an evaluation of its performances has been realised ( back noise, yield, detection limit) and to a checking in real conditions of utilization. (N.C.)

  2. 40 CFR 436.42 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... Industrial Sand Subcategory § 436.42 Effluent limitations guidelines representing the degree of effluent... 6.0 and water quality criteria in water quality standards approved under the Act authorize such lower pH, the pH limitation for such discharge may be adjusted downward to the pH water quality...

  3. Treatment of effluents in uranium industry

    International Nuclear Information System (INIS)

    Ghosh, S.K.

    2009-01-01

    Uranium processing technology in India has matured in the last 50 years and is able to meet the country's requirement. Right from mining of the ore to milling and refining, effluents are generated and are being processed for their safe disposal. While the available technology is able to meet the regulatory limits of the effluents, the same may not be enough to meet the increased demand of uranium in the future. The increased population, urbanization and climate change are not only going to decrease the supply of process water but will also place increased restrictions on disposal to environment. This demands technologies that will generate less effluent for disposal and enable reuse and recycle concept to the extent possible. Presently used conventional physical-chemical methods, to contain the contaminants would, therefore, require further refinements. Contaminants like sulfates, chlorides etc in the effluent of uranium mill based on acid leach process are the concerns for the future plants. Hence, there is an urgent need for development of suitable methods for maximum recycle of the process effluents, which will also enable in minimizing the consumption of process water. A suitable membrane based process can be an option leaving a concentrated brine for reuse or for further treatment and disposal

  4. Potential for reuse of effluent from fish-processing industries

    Directory of Open Access Journals (Sweden)

    Luana Morena Rodrigues Vitor Dias Ferraciolli

    2017-09-01

    Full Text Available The most common problems in the fish processing industry relate to high water consumption and the generation of effluents with concentrated organic loads. Given that reuse can represent an alternative for sustainable development, this study sought to assess the potential for recycling effluents produced in a fish-processing plant. In order to do so, the final industrial effluent was analyzed using the American Public Health Association (APHA standard effluent-analysis method (2005. In addition, the study assessed treatments which produce effluents meeting the requirements prescribed by different countries' regulations for reuse and recycling. The results found that effluents with smaller organic loads, such as those from health barriers and monoblock washing, can be treated in order to remove nutrients and solids so that they can be subsequently reused. For effluents produced by the washing and gutting cylinders, it is recommended that large fragments of solid waste be removed beforehand. Effluents can in this way attain a quality compatible with industrial reuse. This study further highlights the possibility of treating effluents so as comply with drinking water standards. This would potentially allow them to be used within the actual fish-processing procedure; in such a case, a revision of standards and measures for controlling use should be considered to prevent microbiological damage to products and risks to handlers and final consumers.

  5. Turbulent transfer characteristics of radioiodine effluents from air to grass

    Energy Technology Data Exchange (ETDEWEB)

    Markee, E. H. [ARFRO, Environmental Science Services Administration, Idaho Falls, Idaho (United States)

    1967-07-01

    A total of 20 controlled field releases of radioiodine have been performed at the National Reactor Testing Station in Idaho as a portion of a program to study the transmission of gaseous radioiodine through the air-vegetation-cow-milk-human chain. Most of the releases were conducted over typical pasture grasses during different wind and stability conditions. Radioiodine adherence to grass and carbon plates was measured during most of the tests. Vertical air concentration profiles and turbulence parameters were measured to determine flux characteristics. Analysis of the data reveals the complex interdisciplinary nature of transfer of radioiodine from air to a natural surface. The data are in reasonable agreement with the deposition models of Sheppard and Chamberlain when corrections for the physical and biological receptiveness of the grass and grass density are made. The average ratios of momentum to mass flux were found to be 0.9 in stable conditions and 1.4 in unstable conditions. These ratios demonstrate the effect on mass flux in the lowest 4m by a surface that acts as a partial sink for gaseous effluents. This series of releases indicates the need for further research on the biological receptiveness of grass and turbulent transfer within a grass canopy. (author)

  6. Sistemas de serviços de saúde: principais tipologias e suas relações com os sistema de saúde brasileiro

    OpenAIRE

    José Patrício Bispo Júnior; Kelly Leite Maia de Messias

    2005-01-01

    O presente artigo discute as principais características dos Sistemas de Serviços de Saúde e relaciona o Sistema de Saúde Brasileiro com os três principais tipos de Sistemas de Serviços de Saúde. Conceitua e diferencia Sistema de Saúde de Sistemas de Serviços de Saúde. Apresenta a conformação, objetivos, componentes, características e funções dos Sistemas de Serviços de Saúde. Apresenta e discute os três principais tipos de Sistemas de Serviços de Saúde: Sistema de Saúde de Dominância de Me...

  7. Potential Water Retention Capacity as a Factor in Silage Effluent Control: Experiments with High Moisture By-product Feedstuffs

    Science.gov (United States)

    Razak, Okine Abdul; Masaaki, Hanada; Yimamu, Aibibula; Meiji, Okamoto

    2012-01-01

    The role of moisture absorptive capacity of pre-silage material and its relationship with silage effluent in high moisture by-product feedstuffs (HMBF) is assessed. The term water retention capacity which is sometimes used in explaining the rate of effluent control in ensilage may be inadequate, since it accounts exclusively for the capacity of an absorbent incorporated into a pre-silage material prior to ensiling, without consideration to how much the pre-silage material can release. A new terminology, ‘potential water retention capacity’ (PWRC), which attempts to address this shortcoming, is proposed. Data were pooled from a series of experiments conducted separately over a period of five years using laboratory silos with four categories of agro by-products (n = 27) with differing moisture contents (highest 96.9%, lowest 78.1% in fresh matter, respectively), and their silages (n = 81). These were from a vegetable source (Daikon, Raphanus sativus), a root tuber source (potato pulp), a fruit source (apple pomace) and a cereal source (brewer’s grain), respectively. The pre-silage materials were adjusted with dry in-silo absorbents consisting wheat straw, wheat or rice bran, beet pulp and bean stalks. The pooled mean for the moisture contents of all pre-silage materials was 78.3% (±10.3). Silage effluent decreased (p<0.01), with increase in PWRC of pre-silage material. The theoretical moisture content and PWRC of pre-silage material necessary to stem effluent flow completely in HMBF silage was 69.1% and 82.9 g/100 g in fresh matter, respectively. The high correlation (r = 0.76) between PWRC of ensiled material and silage effluent indicated that the latter is an important factor in silage-effluent relationship. PMID:25049587

  8. Potential Water Retention Capacity as a Factor in Silage Effluent Control: Experiments with High Moisture By-product Feedstuffs

    Directory of Open Access Journals (Sweden)

    Okine Abdul Razak

    2012-04-01

    Full Text Available The role of moisture absorptive capacity of pre-silage material and its relationship with silage effluent in high moisture by-product feedstuffs (HMBF is assessed. The term water retention capacity which is sometimes used in explaining the rate of effluent control in ensilage may be inadequate, since it accounts exclusively for the capacity of an absorbent incorporated into a pre-silage material prior to ensiling, without consideration to how much the pre-silage material can release. A new terminology, ‘potential water retention capacity’ (PWRC, which attempts to address this shortcoming, is proposed. Data were pooled from a series of experiments conducted separately over a period of five years using laboratory silos with four categories of agro by-products (n = 27 with differing moisture contents (highest 96.9%, lowest 78.1% in fresh matter, respectively, and their silages (n = 81. These were from a vegetable source (Daikon, Raphanus sativus, a root tuber source (potato pulp, a fruit source (apple pomace and a cereal source (brewer’s grain, respectively. The pre-silage materials were adjusted with dry in-silo absorbents consisting wheat straw, wheat or rice bran, beet pulp and bean stalks. The pooled mean for the moisture contents of all pre-silage materials was 78.3% (±10.3. Silage effluent decreased (p<0.01, with increase in PWRC of pre-silage material. The theoretical moisture content and PWRC of pre-silage material necessary to stem effluent flow completely in HMBF silage was 69.1% and 82.9 g/100 g in fresh matter, respectively. The high correlation (r = 0.76 between PWRC of ensiled material and silage effluent indicated that the latter is an important factor in silage-effluent relationship.

  9. Review of calculational models and computer codes for environmental dose assessment of radioactive releases

    International Nuclear Information System (INIS)

    Strenge, D.L.; Watson, E.C.; Droppo, J.G.

    1976-06-01

    The development of technological bases for siting nuclear fuel cycle facilities requires calculational models and computer codes for the evaluation of risks and the assessment of environmental impact of radioactive effluents. A literature search and review of available computer programs revealed that no one program was capable of performing all of the great variety of calculations (i.e., external dose, internal dose, population dose, chronic release, accidental release, etc.). Available literature on existing computer programs has been reviewed and a description of each program reviewed is given

  10. Review of calculational models and computer codes for environmental dose assessment of radioactive releases

    Energy Technology Data Exchange (ETDEWEB)

    Strenge, D.L.; Watson, E.C.; Droppo, J.G.

    1976-06-01

    The development of technological bases for siting nuclear fuel cycle facilities requires calculational models and computer codes for the evaluation of risks and the assessment of environmental impact of radioactive effluents. A literature search and review of available computer programs revealed that no one program was capable of performing all of the great variety of calculations (i.e., external dose, internal dose, population dose, chronic release, accidental release, etc.). Available literature on existing computer programs has been reviewed and a description of each program reviewed is given.

  11. Sistemas de tiempo real y sistemas distribuidos de tiempo real

    OpenAIRE

    Pesado, Patricia Mabel; Ramón, Hugo Dionisio; Boracchia, Marcos; Pasini, Ariel C.; De Vito, María Cecilia; Osella Massa, Germán Leandro; Estrebou, César Armando

    2006-01-01

    El proyecto de investigación y desarrollo en Sistemas de Software Distribuido, abarca aspectos que van desde los fundamentos del desarrollo (Técnicas de Ingeniería de Requerimientos, Metodologías de Gestión y Desarrollo de Proyectos, Técnicas de Planificación, Métricas, Normas de Calidad, Web-Systems) hasta la concepción de aplicaciones específicas orientadas a los procesos industriales (Sistemas de Planeamiento de Producción, Control Industrial en tiempo real), procesos de E-government (Voto...

  12. Radiation-adsorption purification of effluents containing pesticides

    International Nuclear Information System (INIS)

    Brusentseva, S.A.; Shubin, V.N.; Nikonorova, G.K.; Zorin, D.M.; Sosnovskaya, A.A.; Petryaev, E.P.; Vlasova, V.I.; Edimicheva, I.P.; Subbotina, N.N.; Belorusskij Gosudarstvennyj Univ., Minsk)

    1986-01-01

    The radiation-adsorption purification is one of the new direction in the radiation purification of natural wastes and effluents containing pesticides. This method combines the conventional adsorption purification with radiation treatment of the sorbent, and the result the protection time of the sorbent increases due to the radiation regeneration of carbon. In present work the method was used for purification of effluents from pesticides, such as 4,4'Dichlorodiphenyltrichloroethane /DDT/, 1,2,3,4,5,6-hexachlorocyclohexane /HCCH/, dimethyl 2,2-dichlorovinylphosphate /DDVF/ and petroleum products (a mixture of kerosene and xylene in ratio 7:1). Such effluents are formed at factories producing an insecticide aerosol 'Prime-71'. Three investigations were carried out on model with a solution similar composition to industrial effluents. (author)

  13. Deciphering the Diversities of Astroviruses and Noroviruses in Wastewater Treatment Plant Effluents by a High-Throughput Sequencing Method.

    Science.gov (United States)

    Prevost, B; Lucas, F S; Ambert-Balay, K; Pothier, P; Moulin, L; Wurtzer, S

    2015-10-01

    Although clinical epidemiology lists human enteric viruses to be among the primary causes of acute gastroenteritis in the human population, their circulation in the environment remains poorly investigated. These viruses are excreted by the human population into sewers and may be released into rivers through the effluents of wastewater treatment plants (WWTPs). In order to evaluate the viral diversity and loads in WWTP effluents of the Paris, France, urban area, which includes about 9 million inhabitants (approximately 15% of the French population), the seasonal occurrence of astroviruses and noroviruses in 100 WWTP effluent samples was investigated over 1 year. The coupling of these measurements with a high-throughput sequencing approach allowed the specific estimation of the diversity of human astroviruses (human astrovirus genotype 1 [HAstV-1], HAstV-2, HAstV-5, and HAstV-6), 7 genotypes of noroviruses (NoVs) of genogroup I (NoV GI.1 to NoV GI.6 and NoV GI.8), and 16 genotypes of NoVs of genogroup II (NoV GII.1 to NoV GII.7, NoV GII.9, NoV GII.12 to NoV GII.17, NoV GII.20, and NoV GII.21) in effluent samples. Comparison of the viral diversity in WWTP effluents to the viral diversity found by analysis of clinical data obtained throughout France underlined the consistency between the identified genotypes. However, some genotypes were locally present in effluents and were not found in the analysis of the clinical data. These findings could highlight an underestimation of the diversity of enteric viruses circulating in the human population. Consequently, analysis of WWTP effluents could allow the exploration of viral diversity not only in environmental waters but also in a human population linked to a sewerage network in order to better comprehend viral epidemiology and to forecast seasonal outbreaks. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. Sistema de radiació solar via USB

    OpenAIRE

    Villanueva López, José Vicente

    2008-01-01

    L’objectiu d’aquest projecte és implementar un sistema de mesura de la irradiació solar a la Terra basat en una placa solar fotovoltaica. S’ha dissenyat i construït un sistema de mesura de la radiació solar que pot ser útil per aquells que instal·len sistemes fotovoltaics, que pot permetre l’estudi pràctic de les variables energètiques i econòmiques que ens poden indicar quin sistema és mes rentable construir, si un sistema de pannell solar fix, un sistema de pannell solar o...

  15. Initial integration of accident safety, waste management, recycling, effluent, and maintenance considerations for low-activation materials

    International Nuclear Information System (INIS)

    Piet, S.J.; Herring, J.S.; Cheng, E.T.; Fetter, S.

    1991-01-01

    A true low-activation material should ideally achieve all of the following objectives: 1. The possible prompt dose at the site boundary from 100% release of the inventory should be <2 Sv (200 rem); hence, the design would be inherently safe in that no possible accident could result in prompt radiation fatalities. 2. The possible cancers from realistic releases should be limited such that the accident risk is <0.1%/yr of the existing background cancer risk to local residents. This includes consideration of elemental volatility. 3. The decay heat should be limited so that active mitigative measures are not needed to protect the investment from cooling transients; hence, the design would be passively safe with respect to decay heat. 4. Used materials could be either recycled or disposed of as near- surface waste. 5. Hands-on maintenance should be possible around coolant system piping and components such as the heat exchanger. 6. Effluent of activation products should be minor compared to the major challenge of limiting tritium effluents. The most recent studies in these areas are used to determine which individual elements and engineering materials are low activation. Grades from A (best) to G (worst) are given to each element in the areas of accident safety, recycling, and waste management. Structure/fluid combinations are examined for low-activation effluents and out-of-blanket maintenance. The lowest activation structural materials are silicon carbide, vanadium alloys, and ferritic steels. Impurities and minor alloying constituents must be carefully considered. The lowest activation coolants are helium, water, FLiBe, and lithium. The lowest activation breeders are lithium, lithium oxide, lithium silicate, and FLiBe. Designs focusing on these truly low-activation materials will help achieve the excellent safety and environmental potential of fusion energy

  16. Graphic displays on PCs of gaseous diffusion models of radionuclide releases to the atmosphere

    International Nuclear Information System (INIS)

    Campo Ortega, E. del

    1993-01-01

    The well-known MESOI program has been modified and improved to adapt it to a PC/AT with VGA colour monitor. Far from losing any of its powerful characteristics to calculate the transport, diffusion, deposition and decay of gaseous radioactive effluents discharged to the atmosphere, it has been enhanced to allow graphic viewing of concentrations, wind speed and direction and puff locations in colour, all on a background map of the site. The background covers a 75 x 75 km square and has a graphic grid density of 421 x 421 pixels. This means that effluent concentration is represented approximately every 170 metres in the 'clouded-area'. Among the modifications and enhancements made, the following are of particular interest: 1. A new subroutine called NUBE has been added, which calculates the distribution of effluent concentration of activity in a grid of 421 x 421 pixels. 2. Several subroutines have been added to obtain graphic displays and printouts of the cloud, wind field and puff locations. 3. Graphic display of the geographic plane of the area surrounding the effluent release point. 4. Off-line preparation of meteorological and topographical data files necessary for program execution. (author)

  17. 40 CFR 421.73 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... produced Lead .000 .000 Zinc .000 .000 (d) Subpart G—Dross Reverberatory Slag Granulation. BAT Effluent... per billion pounds) of slag, speiss, or matte granulated Lead 1,612.000 748.400 Zinc 5,872.000 2,418... produced Lead .000 .000 Zinc .000 .000 (g) Subpart G—Hard Lead Refining Slag Granulation. BAT Effluent...

  18. Emulsion-based encapsulation and delivery of nanoparticles for the controlled release of alkalinity within the subsurface environment

    Science.gov (United States)

    Ramsburg, C. A.; Muller, K.; Gill, J.

    2012-12-01

    where acid fluxes are lower. The ability of emulsions to sustain alkalinity release within porous media was preliminarily examined using a series of 1-D column experiments. Emulsions were introduced for 2 pore volumes in a medium sand at Darcy velocities of approximately 0.8 cm/hr. Following the emulsion pulse, a pH 4 solution (adjusted with HCl) was introduced into the column and the effluent was monitored for pH, oil content, and droplet size distributions. All un-retained emulsion (~20% wt. was retained) was flushed from the column within approximately 2 pore volumes of terminating the emulsion pulse. The effluent pH at quasi-steady state and the reactive life of the emulsion depended on the retention characteristics, as well as the type and loading of nanoparticles employed within the emulsion. For the scenarios considered here, quasi-steady effluent pHs were observed to be between 6.5 and 10, and reactive lifetimes (i.e., the number of pore volumes for which the retained emulsion resulted in the effluent pH exceeding that of the influent) were between 15 and 100 pore volumes. These results demonstrate the ability of the emulsion to offer longer-term release and highlight the ability to tune the alkalinity release rate to match site characteristics by adjusting the emulsion content. Current research is directed toward evaluation release properties in heterogeneous aquifer cell experiments.

  19. Study on radioactive release of gaseous and liquid effluents during normal operation of AP1000

    International Nuclear Information System (INIS)

    Gong Quan; Zhou Jing; Liu Yu

    2014-01-01

    The gaseous and liquid radioactive releases of pressurized water reactors plant during normal operation are an important content of environmental impact assessment and play a significant role in the design of nuclear power plant. According to the design characters of AP1OOO radioactive waste management system and the study on the calculation method and the release pathways, the calculation model of the gaseous and liquid radioactive releases during normal operation for AP1OOO are established. Base on the established calculation model and the design parameters of AP1000, the expected value of gaseous and liquid radioactive releases of AP1OOO is calculated. The results of calculation are compared with the limits in GB 6249-2011 and explain the adder that is included tu account for anticipated operational occurrences, providing a reference for environmental impact assessment of pressurized water reactor. (authors)

  20. 40 CFR 418.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Science.gov (United States)

    2010-07-01

    ... solution product: Effluent characteristics Effluent limitations (mg/l) Maximum for any 1 day Average of...) 0.61 0.33 Note: Metric units: Kilogram/1,000 kg of product; English units: Pound/1,000 lb of product....18 0.59 Organic nitrogen (as N) 1.48 0.80 Note: Metric units: Kilogram/1,000 kg of product; English...

  1. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-06-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs

  2. Heavy-metal contamination of agricultural soils irrigated with industrial effluents

    International Nuclear Information System (INIS)

    Nabi, G.; Ashraf, M.; Aslam, M. R.

    2001-01-01

    Pakistan is facing a thread of degradation of water and land-resources by industrial effluents. To evaluated the suitability of these effluents as a source of irrigation for agriculture and the study their effects on soil chemical properties, experiments were conducted in the industrial area of Sheikhupura, where effluent from Paper and Board Mill (PBM), Leather Industry (LI) and Fertilizer Industry (FI) were being used for irrigation. At each site, two fields were selected, one irrigated with industrial effluents and the other with tube-well/canal water. The soil samples were collected and analyzed for pH, ECe, SAR and for heavy metals, such as Cu, Cd, Cr, Zn, Pb, Mn, Fe, Al and Ni. Soil receiving effluent from LI showed higher ECe and SAR values, as compared to the soils receiving other effluents. The concentration of Al was high in the soil irrigated with LI effluent. The Mn and Fe contents were higher in soils irrigated with PBM effluent. Effluent from LI is not fit for irrigation, since its recipient soil showed high concentration of Cr and also high sodicity values. Except Cr, the heavy metals were not of environmental concern. (author)

  3. Evaluation 2000 and regulation and method. Release monitoring and environmental surveillance around Cea centers; Bilan 2000 et reglementation et methode. Controle des rejets et surveillance de l'environnement des centres CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-06-01

    This publication counts for the year 2000 for the evaluation of liquid and gaseous radioactive effluents releases and the radioactivity levels measured in the vicinity of Cea centers, through the air, water, vegetation and milk surveillance. An analysis of the results from 1996 to 2000 allows to follow their evolution. A second booklet develops the sampling and measurement methods made on effluents in environment. It present besides the regulation applied to effluents monitoring. (N.C.)

  4. DOS SISTEMAS AMBIENTAIS AO SISTEMA FLUVIAL – UMA REVISÃO DE CONCEITOS

    Directory of Open Access Journals (Sweden)

    Jonas Otaviano Praça de Souza

    2013-10-01

    Full Text Available Tentando consolidar as noções de totalidade, a geografia física passa a utilizar a noção de sistemas dinâmicos, não lineares e de comportamento caótico. Deste modo, a abordagem sistêmica/complexa apresenta-se como meio de compreensão do mundo natural, assim possibilitando a previsão de mudanças, avaliação dos sistemas ambientais, distúrbios e limiares do sistema. Nota-se, assim, a importância dos estudos processuais para o gerenciamento de recursos hídricos, tornando imprescindíveis estudos sistêmicos que analisem os diversos elementos importantes para a análise dos recursos hídricos, dentre eles as questões processuais. Deste modo, a necessidade de se trabalhar o gerenciamento integrado de recursos hídricos, enquadrado na perspectiva sistêmica, solidificou a bacia hidrográfica e/ou bacia de drenagem como recorte espacial sistêmico. Delimitada a área pode-se compreender a bacia hidrográfica como um Sistema Fluvial, conceituado por Schumm (1977, que é analisado a partir da zona fonte de sedimentos, da rede de transporte e dos sítios de deposição. Esses elementos não são espacialmente excludentes, interagindo entre si, além de apresentar escalas diferenciadas. Para o estudo do sistema fluvial é necessário levar em consideração quatro conceitos: uniformidade dos processos, limiares de mudança, evolução da paisagem e respostas complexas.

  5. Sistema Automatizado de Emailing Marketing

    OpenAIRE

    Martínez López, Javier

    2010-01-01

    Projecte final de carrera realitzat en col.laboració amb E-xpertel S.A El presente proyecto describe el diseño e implementación de un sistema de automatización de campañas de marketing a través de email hacia clientes y/o clientes potenciales. Este sistema tiene como objetivos principales adquirir nuevos clientes y conseguir la delización de los mismos. El sistema se complementa con una plataforma CRM (Customer Relationship Management) para el mantenimiento de datos de empresa...

  6. Bioremediation of the textile waste effluent by Chlorella vulgaris

    OpenAIRE

    El-Kassas, Hala Yassin; Mohamed, Laila Abdelfattah

    2014-01-01

    The microalgae biomass production from textile waste effluent is a possible solution for the environmental impact generated by the effluent discharge into water sources. The potential application of Chlorella vulgaris for bioremediation of textile waste effluent (WE) was investigated using 22 Central Composite Design (CCD). This work addresses the adaptation of the microalgae C. vulgaris in textile waste effluent (WE) and the study of the best dilution of the WE for maximum biomass production...

  7. Legal provisions governing liquid effluents radiological monitoring

    International Nuclear Information System (INIS)

    Gans, I.; Ruehle, H.

    1985-01-01

    The KTA rule 1504 for radiological monitoring of liquid effluents from nuclear installations is explained. As there are no such rules published to date for establishments handling isotopes, some criteria are discussed which in the future ought to form part of a practical guide for liquid effluents monitoring in isotope handling installations. Monitoring measures described refer to liquid effluents from transfer containers, auxiliary cooling equipment, turbine buildings, main cooling installations, and waste air discharges from closed-circuit cooling systems. (DG) [de

  8. WASTE TREATMENT PLANT (WTP) LIQUID EFFLUENT TREATABILITY EVALUATION

    International Nuclear Information System (INIS)

    LUECK, K.J.

    2004-01-01

    A forecast of the radioactive, dangerous liquid effluents expected to be produced by the Waste Treatment Plant (WTP) was provided by Bechtel National, Inc. (BNI 2004). The forecast represents the liquid effluents generated from the processing of Tank Farm waste through the end-of-mission for the WTP. The WTP forecast is provided in the Appendices. The WTP liquid effluents will be stored, treated, and disposed of in the Liquid Effluent Retention Facility (LERF) and the Effluent Treatment Facility (ETF). Both facilities are located in the 200 East Area and are operated by Fluor Hanford, Inc. (FH) for the US. Department of Energy (DOE). The treatability of the WTP liquid effluents in the LERF/ETF was evaluated. The evaluation was conducted by comparing the forecast to the LERF/ETF treatability envelope (Aromi 1997), which provides information on the items which determine if a liquid effluent is acceptable for receipt and treatment at the LERF/ETF. The format of the evaluation corresponds directly to the outline of the treatability envelope document. Except where noted, the maximum annual average concentrations over the range of the 27 year forecast was evaluated against the treatability envelope. This is an acceptable approach because the volume capacity in the LERF Basin will equalize the minimum and maximum peaks. Background information on the LERF/ETF design basis is provided in the treatability envelope document

  9. Zero effluent; Efluente zero

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Silvio Rogerio; Santos, Angelo Francisco dos [Liquigas Distribuidora S.A., Sao Paulo, SP (Brazil)

    2008-07-01

    A scenery of water shortage and the search for profitability improvement obligate the companies to exercise their creativity and to adopt alternative methods to the conventional ones to preserve the environmental resources. The 'Effluent Zero' project comes from a paradigms changing that the environmental preservation is a necessary cost. It brings a new analysis approach of this problem with the purpose to adapt the investments and operational costs with the effluents treatment to the demands of the productive processes. In Liquigas, the project brought significant results; made a potential reduction of nearly 90% in the investments of the effluents treatment systems. That means nearly 13% in reduction in the total investments in modernization and upgrade of the existents companies installations and of 1,6% in the total operational costs of the Company. Further more, it has contributed for a reduction of until 43% of the water consumption in the bottling process of the Liquefied Petroleum Gas (LPG). This way, the project resulted in effective actions of environmental protection with relevant economic benefits. (author)

  10. High-yield pulping effluent treatment technologies

    International Nuclear Information System (INIS)

    Su, W.X.; Hsieh, J.S.

    1993-03-01

    The objective of this report is to examine the high-yield (mechanical) pulp processes with respect to environmental issues affected by the discharge of their waste streams. Various statistics are given that support the view that high-yield pulping processes will have major growth in the US regions where pulp mills are located, and sites for projects in the development phase are indicated. Conventional and innovative effluent-treatment technologies applicable to these processes are reviewed. The different types of mechanical pulping or high-yield processes are explained, and the chemical additives are discussed. The important relationship between pulp yield and measure of BOD in the effluent is graphically presented. Effluent contaminants are identified, along with other important characteristics of the streams. Current and proposed environmental limitations specifically related to mechanical pulp production are reviewed. Conventional and innovative effluent-treatment technologies are discussed, along with their principle applications, uses, advantages, and disadvantages. Sludge management and disposal techniques become an intimate part of the treatment of waste streams. The conclusion is made that conventional technologies can successfully treat effluent streams under current waste-water discharge limitations, but these systems may not be adequate when stricter standards are imposed. At present, the most important issue in the treatment of pulp-mill waste is the management and disposal of the resultant sludge

  11. Sulphate removal from industrial effluents through barium sulphate precipitation

    CSIR Research Space (South Africa)

    Swanepoel, H

    2011-11-01

    Full Text Available The pollution of South Africa’s water resources puts a strain on an already stressed natural resource. One of the main pollution sources is industrial effluents such as acid mine drainage (AMD) and other mining effluents. These effluents usually...

  12. Aqueous studies of hydrogen sulfide releases from a heavy water extraction facility

    International Nuclear Information System (INIS)

    Kiser, D.L.

    1979-03-01

    Upsets in the operation of the wastewater strippers in the 400 Area of the Savannah River Plant have released hydrogen sulfide in quantities as large as 1800 kg to the effluent stream. Fish kills in the swamp area of Beaver Dam Creek have occurred following the large releases. A literature survey revealed volatilization and oxidation as the major loss mechanisms of H 2 S. Laboratory investigations supported the literature survey. The computer code for pollutant transport in a stream, LODIPS, has an option to account for sink-source effects in a stream. Volatilization and oxidation rate constants were developed for the sink option from two H 2 S releases (18 kg and 118 kg) and results were predicted with LODIPS. Based on the predicted concentration-time profiles for various hypothetical cases, releases as small as 568 kg if discharged over a 30-minute period or releases as large as 1818 kg if discharged over a 360-minute period or less are lethal to swamp fish

  13. Facility Effluent Monitoring Plan for the uranium trioxide facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  14. Review of radionuclides released from the nuclear fuel cycle and methods of assessing dose to man

    International Nuclear Information System (INIS)

    Bryant, P.M.

    1979-01-01

    There are two broad subject areas associated with releases of radionuclides from nuclear fuel cycle installations to the environment in which there are biological implications. One concerns interpretation of doses to man in terms of their radiological significance; the other concerns estimation of environmental transfer of radionuclides and of associated radiation doses to man. The radiation protection philosophy on which past practice regarding effluent releases of radionuclides to the environment was based is illustrated by drawing upon estimates of the associated radiation doses to man given in the 1977 report of the United Nations Scientific Committee on the Effects of Atomic Radiation. The present emphasis in radiation protection philosophy is illustrated by summarizing a review of environmental models relevant to estimation of radiation doses to population groups with reference to effluent releases of 3 H, 14 C, 85 Kr and 129 I; the author carried out the review as a contribution to a current study by an expert group set up by the Nuclear Energy Agency of OECD. Radionuclides of significance in the future may differ from those currently released to the environment because of possible developments in nuclear fuel cycles and options which may be exercised for disposal of high-level radioactive wastes, already in storage or postulated to be produced in the future. (author)

  15. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Geiger, J.L.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified. in. A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  16. Utilization of biogas released from palm oil mill effluent for power generation using self-preheated reactor

    International Nuclear Information System (INIS)

    Hosseini, Seyed Ehsan; Wahid, Mazlan Abdul

    2015-01-01

    Highlights: • A lab-scale reactor called self-preheating flameless combustion (SPFC) system is experimented. • Feasibility of power generation by POME biogas is modeled using SPFC system. • 4 MW power is available by POME biogas utilization in a typical palm oil mill with 300,000 tons production. • The rate of power generation increases when 2% hydrogen is added to POME biogas ingredients. - Abstract: In palm oil mills, for one ton crude palm oil (CPO) production, 70 m"3 biogas is released from palm oil mill effluent (POME) which can endanger the environment. Palm oil mills without appropriate strategies for biogas collection can participate in greenhouse gases (GHGs) generation actively. In this paper, a typical palm oil mill with annual capacity of 300,000 ton oil palm production and 3 MW electricity demand is considered as a pilot plant and feasibility of power generation by POME biogas is modeled by Aspen Plus considering flameless mode in combustion system. A new design of lab-scale flameless reactor called self-preheated flameless combustion (SPFC) system is presented and employed in power generation modeling. In SPFC system, the flameless chamber is employed as a heater to preheat an oxidizer over the self-ignition temperature of the fuel. A helical stainless steel pipe (called self-preheating pipe) is installed inside the chamber to conduct the oxidizer from exhaust zone to the combustion zone inside the chamber and preheat oxidizer. In the flameless mode, the diluted oxidizer is injected to the helical pipe from the exhaust zone and the preheated oxidizer at the burner is conducted to the flameless furnace through a distributor. In SPFC system external heater for preheating oxidizer is removed and the rate of power generation increases. The results show that 10.8 MW power could be generated in ultra-lean POME biogas SPFC. However, the rate of pollutant especially CO_2 and NO_x is high in this circumstances. In stoichiometric condition, 4 MW power

  17. Separation of tritium from reprocessing effluents

    International Nuclear Information System (INIS)

    Bruggeman, A.; Doyen, W.; Harnie, R.; Leysen, R.; Meynendonckx, L.; Monsecour, M.; Goossens, W.R.A.; Baetsle, L.H.

    1980-01-01

    For several years tritium retention has been studied at the Belgian Nuclear Research Centre, SCK/CEN; initially attention was focused on the removal of tritium from gaseous reprocessing effluents. If tritium can be released from the spent fuel into the gaseous phase before any aqueous operation, adsorption on molecular sieves after some isotopic dilution with hydrogen and after complete conversion to (tritiated) water is the most practical collection method. A once-through 15 m 3 .h -1 oxidation-adsorption unit with a closed regeneration system and with a decontamination factor of 1000 at total (tritiated) hydrogen and water inlet concentrations down to 1000 vpm (parts per million by volume) has been constructed and tested at SCK/CEN and it is described in the text. If no special head-end treatment is used an appropriate liquid management inside the reprocessing plant restricts the volume of tritiated aqueous effluents to about 3 m 3 per tonne of LWR fuel processed. However, for further reduction an isotope separation process becomes necessary. SCK/CEN is developing the ELEX process, which is a combination of water ELectrolysis and tritium EXchange between hydrogen and water, the exchange being promoted by a hydrophobic catalyst. For electrolysis under normal conditions an elementary tritium separation factor of 11.6 with a standard deviation of 6% was obtained. As concerns the exchange step a hydrophobic catalyst has been developed which yields for the flow rates used at atmospheric pressure and at 20 0 C an overall exchange rate constant of 9 mol.s -1 .m -3 in a countercurrent trickle-bed reactor. At present an integrated bench scale de-tritiation unit is being built for further tests and for a dynamic demonstration of the ELEX process

  18. Importancia del manual de los sistemas contables en el sistema de control interno.

    Directory of Open Access Journals (Sweden)

    Nicolás Valdés Rodríguez

    2007-01-01

    Full Text Available La dirección administrativa del país en los últimos 3 años ha insistido en la necesidad de profundizar en los mecanismos de control económico –financiero de las entidades, el presente trabajo va dirigido a contribuir en alguna medida a lograr ese propósito. El sistema contable de una Entidad forma parte indisoluble del Sistema de Control Interno de la misma, por la vinculación tan estrecha que existe entre los mismos. El objetivo fundamental del trabajo ”Importancia del Manual de los Sistemas Contables en el Sistema de Control Interno”, es destacar la utilidad práctica, técnica y organizativa que tiene el Manual para elevar la eficiencia del trabajo contable de las Entidades y su repercusión positiva en la eficiencia el sistema de Control Interno establecido. Los beneficios que aporta el Manual radican en que crea una base normativa contable adecuada a las características de cada entidad. Como se sabe en las transformaciones económicas realizadas en el país, la existencia de dos monedas en el trabajo económico-contable de muchas entidades, la puntualización del objeto social y la cartera de productos y servicios han complejizado el trabajo contable, requiriendo una mayor adecuación a las características propias de cada entidad, lo cual se logra con la realización del Manual.

  19. Technical treatment options for the mill effluents of the Los Gigantes Complex

    International Nuclear Information System (INIS)

    Asenjo, A.R.

    2002-01-01

    The Mining/Milling Los Gigantes Complex is located in Cordoba Province, about 100 km to the West of the capital city. The uranium mining and milling activities have been carried out during the period between 1980 and 1990. As result of those activities, mine wastes, low grade ore, sludge, heap leach wastes and liquid effluents have been accumulated in the site. At present, the National Atomic Energy Commission of Argentina is developing the Remediation Project of the site. Within the frame of this Project it is necessary to define the liquid effluent treatment methodology of the liquids accumulated in a pond in order to achieve the proper quality to be released to the environment, according with the national and provincial regulations. In this paper several liquid treatment methods are described. These methods were also developed at the lab scale. Among these we can mention hot and cool alcalinization with barium chloride addition and ion exchange resins treatments. Also a pilot scale assay has been done in the site (about 450 m 3 ) in order to verify the obtained lab scale results. Nevertheless that other assays are yet under developing, the obtained results are reported. (author)

  20. Bioremediation of the textile waste effluent by Chlorella vulgaris

    Directory of Open Access Journals (Sweden)

    Hala Yassin El-Kassas

    2014-01-01

    Full Text Available The microalgae biomass production from textile waste effluent is a possible solution for the environmental impact generated by the effluent discharge into water sources. The potential application of Chlorella vulgaris for bioremediation of textile waste effluent (WE was investigated using 22 Central Composite Design (CCD. This work addresses the adaptation of the microalgae C. vulgaris in textile waste effluent (WE and the study of the best dilution of the WE for maximum biomass production and for the removal of colour and Chemical Oxygen Demand (COD by this microalga. The cultivation of C. vulgaris, presented maximum cellular concentrations Cmax and maximum specific growth rates μmax in the wastewater concentration of 5.0% and 17.5%, respectively. The highest colour and COD removals occurred with 17.5% of textile waste effluent. The results of C. vulgaris culture in the textile waste effluent demonstrated the possibility of using this microalga for the colour and COD removal and for biomass production. There was a significant negative relationship between textile waste effluent concentration and Cmax at 0.05 level of significance. However, sodium bicarbonate concentration did not significantly influence the responses of Cmax and the removal of colour and COD.

  1. New approaches to deriving limits of the release of radioactive material into the environment

    International Nuclear Information System (INIS)

    Lindell, B.

    1977-01-01

    During the last few years, new principles have been developed for the limitation of the release of radioactive material into the environment. It is no longer considered appropriate to base the limitation on limits for the concentrations of the various radionuclides in air and water effluents. Such limits would not prevent large amounts of radioactive material from reaching the environment should effluent rates be high. A common practice has been to identify critical radionuclides and critical pathways and to base the limitation on authorized dose limits for local ''critical groups''. If this were the only limitation, however, larger releases could be permitted after installing either higher stacks or equipment to retain the more short-lived radionuclides for decay before release. Continued release at such limits would then lead to considerably higher exposure at a distance than if no such installation had been made. Accordingly there would be no immediate control of overlapping exposures from several sources, nor would the system guarantee control of the future situation. The new principles described in this paper take the future into account by limiting the annual dose commitments rather than the annual doses. They also offer means of controlling the global situation by limiting not only doses in critical groups but also global collective doses. Their objective is not only to ensure that individual dose limits will always be respected but also to meet the requirement that ''all doses be kept as low as reasonably achievable''. The new approach is based on the most recent recommendations by the ICRP and has been described in a report by an IAEA panel (Procedures for establishing limits for the release of radioactive material into the environment). It has been applied in the development of new Swedish release regulations, which illustrate some of the problems which arise in the practical application

  2. New approaches to deriving limits of the release of radioactive material into the environment

    International Nuclear Information System (INIS)

    Lindell, B.

    1977-01-01

    During the last few years, new principles have been developed for the limitation of the release of radioactive material into the environment. It is no longer considered appropriate to base the limitation on limits for the concentrations of the various radionuclides in air and water effluents. Such limits would not prevent large amounts of radioactive material from reaching the environment should effluent rates be high. A common practice has been to identify critical radionuclides and critical pathways and to base the limitation on authorized dose limits for local ''critical groups''. If this were the only limitation, however, larger releases could be permitted after installing either higher stacks or equipment to retain the more shortlived radionuclides for decay before release. Continued release at such limits would then lead to considerably higher exposure at a distance than if no such installation had been made. Accordingly there would be no immediate control of overlapping exposures from several sources, nor would the system guarantee control of the future situation. The new principles described in this paper take the future into account by limiting the annual dose commitments rather than the annual doses. They also offer means of controlling the global situation by limiting not only doses in critical groups but also global collective doses. Their objective is not only to ensure that individual dose limits will always be respected but also to meet the requirement that ''all doses be kept as low as reasonably achievable''. The new approach is based on the most recent recommendations by the ICRP and has been described in a report by an IAEA panel (Procedures for Establishing Limits for the Release of Radioactive Material into the Environment). It has been applied in the development of new Swedish release regulations, which illustrate some of the problems which arise in the practical application. (author)

  3. Factors Affecting Distribution of Estrogenicity in the Influents, Effluents, and Biosolids of Canadian Wastewater Treatment Plants.

    Science.gov (United States)

    Shieh, Ben H H; Louie, Alvin; Law, Francis C P

    2016-05-01

    Canadian wastewater treatment plants (WWTPs) release significant amounts of estrogenic chemicals to nearby surface waters. Environmental estrogens have been implicated as the causative agents of many developmental and reproductive problems in animals, including fish. The goals of this study were to assess the estrogenic activity in the influents, effluents, and biosolids of thirteen Canadian WWTPs using the yeast estrogen screen (YES) bioassay and to investigate whether factors, such as wastewater treatment method, sample storage, extraction efficiency, population, and summer/winter temperature had any effects on the distribution of estrogenicity in the WWTPs. Results of the study showed that estrogenicity from the influent to the effluent decreased in seven WWTPs, increased in two WWTPs, and did not change in four WWTPs during the winter. Estrogenic concentrations generally decreased in the order of biosolids > influents > effluents and ranged from 1.57 to 24.6, 1.25E-02 to 3.84E-01, and 9.46E-03 to 3.90E-01 ng estradiol equivalents/g or ml, respectively. The estrogenicity in the final effluents, but not those in the influents and biosolids, was significantly higher in the summer than the winter. Among the WWTP treatment methods, advanced, biological nutrient removal appeared to be the most effective method to remove estrogenic chemicals from wastewaters in Canada. Our studies help to identify factors or mechanisms that affect the distribution of estrogenicity in WWTPs, providing a better understanding on the discharges of estrogenic chemicals from WWTPs.

  4. Sistema de inferencia difusa basado en relaciones Booleanas

    Directory of Open Access Journals (Sweden)

    Helbert Eduardo Espitia Cuchango

    2010-09-01

    Full Text Available Este documento describe la estructura de un sistema de inferencia difusa basado en relaciones booleanas. La teoría relacionada con lógica y conjuntos booleanos es una buena herramienta para el diseño de automatismos y sistemas digitales. Una variación con la cual se busca mejorar los sistemas basados en automatismos consiste en emplear conjuntos difusos en lugar de booleanos. Lo anterior se realiza con el objetivo de tener una acción continua en el actuador del automatismo. Al realizar esta variación y al aplicar la metodología de diseño de los sistemas de automatismos, aparecen los sistemas de inferencia difusa basados en relaciones booleanas.Aunque inicialmente esta propuesta se realizó considerando sistemas de automatismos, se observa que es posible extenderla a sistemas de inferencia difusa.

  5. Assessment of Physicochemical and Biochemical Qualities of Tannery Effluents of Hazaribagh, Dhaka, and Comparison with Non-Tannery Water Samples

    Directory of Open Access Journals (Sweden)

    Laila N. Islam

    2015-02-01

    Full Text Available NOTE: on 21st May 2015, the authors Mahmud Hossain and M Mohasin were added to the online information about the article. The PDF remains correct.In this study the physicochemical and biochemical qualities of the tannery effluents were analyzed to determine the pollution load of the openly released wastewaters in the environment and the findings were compared with the non-tannery waters. Fourteen samples of factory effluents were collected from the leather tanning industrial zone of Hazaribagh, Dhaka, and 13 non-tannery water samples were collected from different parts of Dhaka city. The effluents were mostly colored; their pH varied from highly acidic to basic values while densities were not much different from the non-tannery waters. The chromium contents of the effluents varied from less than 0.002 to 18.97 mg/L and the chemical oxygen demands (COD varied from 90 to 6500 mg/L, which were significantly higher than those of non-tannery waters. There was a strong direct correlation between chromium content and COD (p<0.01 indicating that chromium was hugely responsible for pollution caused by tannery effluents. The tannery wastewaters were highly toxic to brine shrimp nauplii (lethality: about 82%, and chromium was responsible for biotoxicity of the effluents since a direct significant correlation (p<0.021 was found between chromium content and lethality. Storage of the wastewater samples for 2 to 8 months at room temperature showed rise in the pH values possibly due to microbial action that resulted in decrease of dissolved chromium content from a mean value of 7.94 to 5.09 mg/L. These findings demonstrated that the presence of high concentrations of chromium and other chemicals in the untreated tannery effluents were contributing adverse effects on the environment and ecosystem.DOI: http://dx.doi.org/10.3126/ije.v4i1.12179International Journal of Environment Volume-4, Issue-1, Dec-Feb 2014/15, page: 68-81  

  6. Estudo da utilização do efluente de biodigestor no cultivo hidropônico do meloeiro Utilization of biodigestor effluent in the hydroponic cultivation of melon

    Directory of Open Access Journals (Sweden)

    Luiz V. E. Villela Junior

    2003-04-01

    Full Text Available Objetivando-se o aproveitamento do efluente de biodigestor no cultivo hidropônico do meloeiro, desenvolveu-se a presente pesquisa. O experimento foi conduzido no Departamento de Engenharia Rural da Faculdade de Ciências Agrárias e Veterinárias da UNESP, campus de Jaboticabal, cultivando-se o meloeiro (Cucumis melo L. cv. Bonus nº 2. O delineamento experimental utilizado foi em blocos casualisados, com 6 repetições, cujos tratamentos foram: 1 cultivo hidropônico em sistema fechado tipo NFT ("nutrient film technique" com uso de solução nutritiva organo-mineral (biofertilizante com complementação mineral; 2 cultivo hidropônico em sistema fechado tipo NFT, com uso de solução nutritiva 100% mineral; 3 cultivo hidropônico em sistema aberto, com substrato e solução nutritiva organo-mineral e 4 cultivo hidropônico em sistema aberto, com substrato e solução nutritiva 100% mineral. O biofertilizante e o substrato foram obtidos a partir do efluente de biodigestor, produzido com estrume bovino. As plantas cultivadas no tratamento 1 tiveram desenvolvimento prejudicado, devido ao acúmulo de partículas sólidas junto ao sistema radicular. O tratamento 2 proporcionou às plantas desenvolvimento vegetativo mais rápido e maior produtividade. Os frutos produzidos no tratamento 2 apresentaram maior peso, formato mais alongado e maior teor de sólidos solúveis totais. A substituição parcial de adubos minerais por biofertilizante mostrou-se possível em sistema hidropônico aberto com substrato.With the objective to use effluent of biodigestor in the hydroponic cultivation, an experiment was conducted in the Department of Rural Engineering Faculty of Agricultural and Veterenary Sciences of UNESP, campus of Jaboticabal where a melon crop (Cucumis melo L. cv. Bonus nº 2 was cultivated. The experimental design used was a randomized blocks, with 6 repetitions and the treatments studied were: 1 hydroponic cultivation in closed system type NFT

  7. Decision no 2009-DC-0156 of the 15. of September 2009 by the Nuclear Safety Authority specifying instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from the base nuclear installations n. 18, 35, 40, 49, 50, 72, 77 and 101 operated by the Atomic Energy Commissariat (CEA) in its Saclay Centre, located on the districts of Saclay, Saint-Aubin and Villiers-le-Bacle (Essonne department)

    International Nuclear Information System (INIS)

    2009-01-01

    After references to the different legal and official documents (codes, orders, minister's opinion, public surveys, administrative authorizations, local community opinion), this document specifies the instructions related to modalities of water sampling and consumption, and of release in the environment of liquid and gaseous effluents from some specific base nuclear installations. These instructions and provisions concern the general means implemented by the operator, records, the control by authorities, the limits of water sampling and consumption, the water sampling process, the sampling works and their maintenance and control, the release of liquid, gaseous and radioactive effluents, their control and their transfer, the limit values for different compounds and species, the control of environment around the site, the information of authorities and of population

  8. Sistemas híbrido de produção de energia para sistema de comunicações rádio

    OpenAIRE

    Carreiras, José Manuel Patrício

    2014-01-01

    Mestrado em Sistemas de Energias Renováveis na Escola Superior de Tecnologia e Gestão do Instituto Politécnico de Viana do Castelo Este trabalho de projeto incidiu sobre o dimensionamento de cinco sistemas Autónomos de produção de energia para alimentação de Pontos repetidores do sistema de comunicação e sua implementação. O presente trabalho iniciou-se em 2006 quando por motivos profissionais foi necessário construir um sistema de comunicação de suporte ao sistema de telegestã...

  9. Asymptomatic Effluent Protozoa Colonization in Peritoneal Dialysis Patients.

    Science.gov (United States)

    Simões-Silva, Liliana; Correia, Inês; Barbosa, Joana; Santos-Araujo, Carla; Sousa, Maria João; Pestana, Manuel; Soares-Silva, Isabel; Sampaio-Maia, Benedita

    Currently, chronic kidney disease (CKD) is a global health problem. Considering the impaired immunity of CKD patients, the relevance of infection in peritoneal dialysis (PD), and the increased prevalence of parasites in CKD patients, protozoa colonization was evaluated in PD effluent from CKD patients undergoing PD. Overnight PD effluent was obtained from 49 asymptomatic stable PD patients. Protozoa analysis was performed microscopically by searching cysts and trophozoites in direct wet mount of PD effluent and after staining smears. Protozoa were found in PD effluent of 10.2% of evaluated PD patients, namely Blastocystis hominis, in 2 patients, and Entamoeba sp., Giardia sp., and Endolimax nana in the other 3 patients, respectively. None of these patients presented clinical signs or symptoms of peritonitis at the time of protozoa screening. Our results demonstrate that PD effluent may be susceptible to asymptomatic protozoa colonization. The clinical impact of this finding should be further investigated. Copyright © 2016 International Society for Peritoneal Dialysis.

  10. Um modelo de enfermagem como sistema complexo adaptativo

    Directory of Open Access Journals (Sweden)

    Mariana Vieira

    2009-01-01

    Full Text Available El surgimiento y el uso de los sistemas complejos adaptativos suplieron la necesidad de contar con una nueva alternativa, recurriendo a los paradigmas existentes. En cuanto al sistema de salud y de enfermería, ambos pueden verse como sistemas complejos adaptativos al aplicar un modelo visual que debe ser explorado para potenciar la complejidad de la ciencia de enfermería y de cuidados de salud. Desde esta perspectiva, el/la enfermero/a es un sistema complejo adaptativo, dinámico que interactúa, pero también es agente de un sistema complejo adaptativo en una unidad de enfermería, que a la vez es un sistema complejo adaptativo en una organización de la salud. Hoy en día la/el profesional de enfermería busca actualizarse y cualificarse en diversas especialidades, que van desde enfermería neonatal hasta cuidados geriátricos, para ejecutar sus actividades y visualizar su ambiente laboral desde la perspectiva de un sistema complejo. En consecuencia, la organización del sistema de cuidados permite, mediante los sistemas complejos, apoyarse en el saber compartido de los diversos profesionales y en el trabajo en equipo para disfrutar la complicidad de la cadena cliente-usuario-profesionales.

  11. Facility Effluent Monitoring Plan for the Plutonium Finishing Plant

    International Nuclear Information System (INIS)

    FRAZIER, T.P.

    1999-01-01

    A facility effluent monitoring plan is required by the U. S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. To ensure the long-range integrity of the effluent monitoring systems, an update to this facility effluent monitoring plan is required whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document is reviewed annually even if there are no operational changes, and is updated, at a minimum, every 3 years

  12. Del Actual Sistema de Enfermedad a un verdadero Sistema de Salud

    Directory of Open Access Journals (Sweden)

    Lidice Alvarez-Miño

    2018-01-01

    Full Text Available Esta editorial tiene como objetivo generar una reflexión y abrir el debate sobre el sistema actual de salud que se refleja en prácticas naturalizadas  que se contradicen con la esencia del significado de la salud. Se trata de la costumbre de acudir al sistema de salud únicamente cuando se considera que se está enfermo, o peor aún, la equivalencia reduccionista y casi automática del concepto de salud como sinónimo de medicina.

  13. Dispersal of plutonium from an effluent pulse in the Great Miami River

    International Nuclear Information System (INIS)

    Sprugel, D.G.; Muller, R.N.; Bartelt, G.E.; Wayman, C.W.; Bobula, C.M.

    1975-01-01

    The concentration of soluble 238 Pu was found to be proportional to the concentration of the Rhodamine WT dye released from Mound Laboratory to the Great Miami River in an effluent pulse. This correlation permitted the integration of the area under the curves obtained from the dye monitoring to be equated to the total soluble 238 Pu present in the pulse. Investigations of the uptake of pulse-associated 238 Pu by organisms in the river proved inconclusive. It does appear, however, that organisms including the alga, Cladophora, which is known to concentrate plutonium, do not exhibit rapid changes in uptake coincident with the passage of the pulse

  14. General principles governing sampling and measurement techniques for monitoring radioactive effluents from nuclear facilities

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1978-01-01

    An explanation is given of the need to monitor the release of radioactive gases and liquid effluents from nuclear facilities, with particular emphasis on the ICRP recommendations and on the interest in this problem shown by the larger international organizations. This is followed by a description of the classes of radionuclides that are normally monitored in this way. The characteristics of monitoring 'in line' and 'by sample taking' are described; the disadvantages of in line monitoring and the problem of sample representativity are discussed. There follows an account of the general principles for measuring gaseous and liquid effluents that are applied in the techniques normally employed at nuclear facilities. Standards relating to the specifications for monitoring instruments are at present being devised by the International Electrotechnical Commission, and there are still major differences in national practices, at least as far as measurement thresholds are concerned. In conclusion, it is shown that harmonization of practices and standardization of equipment would probably help to make international relations in the field more productive. (author)

  15. Behavior and removal of organic species in the Savannah River Plant effluent treatment facility

    International Nuclear Information System (INIS)

    Oblath, S.B.; Georgeton, G.K.

    1988-01-01

    The effluent treatment facility (ETF) at the Savannah River Plant (SRP) is a new facility designed to treat and decontaminate low-level radioactive wastewater prior to release to the environment. The wastewater is primarily composed of evaporator overheads from the chemical separations and waste handling facilities at SRP. Primarily a 2000 mg/L NaNO 3 solution, the wastewater also contains microcurie-per-liter quantities of radionuclides and milligram-per-liter concentrations of heavy metals and organic components. This paper shows a block diagram of the major process steps. The pH adjustment, filtration, mercury removal, reverse osmosis, and cation-exchange polishing steps give a significant reduction of inorganic species and radionuclide (except trittium) concentrations. The activated carbon removal step was recently added to remove organic species to ensure that the effluent discharge permit limits for oil and grease and biochemical oxygen demand are met. The concentrates and regenerates from each of the treatment steps are further concentrated by evaporation to reduce the volume sufficiently for incorporation into and disposal as a grout

  16. 324 and 327 Facilities Environmental Effluent Specifications

    International Nuclear Information System (INIS)

    JOHNSON, D.L.

    1999-01-01

    These effluent specifications address requirements for the 324/321 Facilities, which are undergoing stabilization activities. Effluent specifications are imposed to protect personnel, the environment and the public, by ensuring adequate implementation and compliance with federal and state regulatory requirements and Hanford programs

  17. Polishing of Anaerobic Secondary Effluent and Symbiotic Bioremediation of Raw Municipal Wastewater by Chlorella Vulgaris

    KAUST Repository

    Cheng, Tuoyuan

    2016-05-01

    To assess polishing of anaerobic secondary effluent and symbiotic bioremediation of primary effluent by microalgae, bench scale bubbling column reactors were operated in batch modes to test nutrients removal capacity and associated factors. Chemical oxygen demand (COD) together with oil and grease in terms of hexane extractable material (HEM) in the reactors were measured after batch cultivation tests of Chlorella Vulgaris, indicating the releasing algal metabolites were oleaginous (dissolved HEM up to 8.470 mg/L) and might hazard effluent quality. Ultrafiltration adopted as solid-liquid separation step was studied via critical flux and liquid chromatography-organic carbon detection (LC-OCD) analysis. Although nutrients removal was dominated by algal assimilation, nitrogen removal (99.6% maximum) was affected by generation time (2.49 days minimum) instead of specific nitrogen removal rate (sN, 20.72% maximum), while phosphorus removal (49.83% maximum) was related to both generation time and specific phosphorus removal rate (sP, 1.50% maximum). COD increase was affected by cell concentration (370.90 mg/L maximum), specific COD change rate (sCOD, 0.87 maximum) and shading effect. sCOD results implied algal metabolic pathway shift under nutrients stress, generally from lipid accumulation to starch accumulation when phosphorus lower than 5 mg/L, while HEM for batches with initial nitrogen of 10 mg/L implied this threshold around 8 mg/L. HEM and COD results implied algal metabolic pathway shift under nutrients stress. Anaerobic membrane bioreactor effluent polishing showed similar results to synthetic anaerobic secondary effluent with slight inhibition while 4 symbiotic bioremediation of raw municipal wastewater with microalgae and activated sludge showed competition for ammonium together with precipitation or microalgal luxury uptake of phosphorus. Critical flux was governed by algal cell concentration for ultrafiltration membrane with pore size of 30 nm, while

  18. Facility effluent monitoring plan for the tank farm facility

    Energy Technology Data Exchange (ETDEWEB)

    Crummel, G.M.

    1998-05-18

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements.

  19. GASPAR-II, Radiation Exposure to Man from Air Releases of Reactor Effluents

    International Nuclear Information System (INIS)

    1993-01-01

    1 - Description of program or function: GASPAR implements the air release dose models of the NRC Regulatory Guide 1.109 for noble gases (semi-infinite plume only) and the radioiodine and particulate emissions. GASPAR computes both population (ALARA-As Low As Reasonably Achievable and NEPA-National Environmental Policy Act) and individual doses. Site data, meteorological data, radionuclide release source terms, and location meteorological data for selected individuals are specified as input data. The site data includes population data and milk, meat, and vegetation production. The meteorological data includes dispersion X/Q, X/Q decayed, X/Q decayed and depleted, and deposition. Population doses, individual doses, and cost benefit tables are calculated. 2 - Method of solution: There are two basic types of calculations, the population dose calculation and the individual dose calculation; however, both may be combined in a single GASPAR execution. There are usually several source terms corresponding to several release points. As the dose is computed for each source term it is accumulated so that the dose printed for the first source term is the actual dose for that term. For all subsequent source terms the dose printed is the accumulated dose with the dose printed for the last source term, the grand total for the problem. For the cost benefit table, individual source term doses are generated. Seven pathways by which the nuclides travel to man are considered. These are plume, ground, inhalation, vegetation, cows' milk, goats' milk, and meat. For the individual dose calculations, man is subdivided into the four age groups of infant (0 to 1 year), child (1-11 years), teenager (12-18 years) and adult (over 18 years). Each of these calculations take into account eight body organs - T. body, G.I. track, bone, liver, kidney, thyroid, lung, and skin. 3 - Restrictions on the complexity of the problem: None noted

  20. Facility effluent monitoring plan for the fast flux test facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Dahl, N.R.

    1992-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in US Department of Energy Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A Facility Effluent Monitoring Plan determination was performed during calendar year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  1. French studies on the thermal effluents of electric power plants

    International Nuclear Information System (INIS)

    Dezes-Cadiere, H.

    1976-01-01

    This report presents a synthesis of studies made in France in the thermal effluent field: thermal power plant cooling systems, transfer and dispersion of thermal effluents in the receptive media, effects of thermal effluents on water physicochemistry and biochemistry, effects of thermal effluents on aquatic ecosystems, and, possibilities of waste heat recovery with the view of utilization in agriculture, aquaculture and district heating. A catalogue of French organizations working or having data on thermal effluents is presented, as also an alphabetical list of the contacted persons. A bibliography of French documents concerning the previously mentioned studies is finally given (193 refs.) [fr

  2. Facility Effluent Monitoring Plan for the 222-S Laboratory

    International Nuclear Information System (INIS)

    Robinson, A.V.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems against applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. The current operation of the 222-S facilities includes the provision of analytical and radiological chemistry services in support of Hanford Site processing plants. The emphasis is on waste management, chemical processing, environmental monitoring effluent programs at B Plant, the Uranium Oxide Plant, Tank Farms, the 242-A Evaporator, the Waste Encapsulation and Storage Facility, the Plutonium-Uranium Extraction Facility, the Plutonium Finishing Plant, process development/impact activities, and essential materials. The laboratory also supplies analytical services in support of ongoing waste tank characterization

  3. O sistema social da saúde: conceito, limites e possibilidades

    Directory of Open Access Journals (Sweden)

    Sandra Regina Martini Vial

    2014-06-01

    Full Text Available Discutem-se as possibilidades de definir o sistema da saúde como um sistema social, diferenciado funcionalmente, a partir da ótica da Teoria dos Sistemas Sociais, utilizando os pressupostos gerais da Teoria e a estrutura apresentada por Niklas Luhmann sobre o sistema médico. Apresentam-se alguns “desassossegos” provocados pela Teoria; as possíveis relações entre o sistema da saúde e o que Luhmann chamou de sistema médico e como esse sistema, atualmente, pode ser considerado sistema da saúde; e, por fim, a nossa concepção do sistema da saúde na atualidade.

  4. Source terms for airborne effluents

    International Nuclear Information System (INIS)

    Blomeke, J.O.; Perona, J.J.

    1976-01-01

    The origin and nature of fuel cycle wastes are discussed with regard to high-level wastes, cladding, noble gases, iodine, tritium, 14 C, low-level and intermediate-level transuranic wastes, non-transuranic wastes, and ore tailings. The current practice for gaseous effluent treatment is described for light water reactors and high-temperature gas-cooled reactors. Other topics discussed are projections of nuclear power generation; projected accumulation of gaseous wastes; the impact of nuclear fuel cycle centers; and global buildup of airborne effluents

  5. Intelligent tutorial system for selftraining in tuning of control systems; Sistema tutorial inteligente para el autoentrenamiento en sintonizacion de sistemas de control

    Energy Technology Data Exchange (ETDEWEB)

    Romero Jimenez, Guillermo; Perez Ocampo, Maria Concepcion [Instituto de Investigaciones Electricas, Temixco, Morelos (Mexico)

    1999-07-01

    In this paper the design, development and validation of an intelligent tutorial system oriented to the instruction of techniques of tuning of control systems is described. This system is based on systems previously developed in the Simulation Unit of the Instituto de Investigaciones Electricas (IIE). The designed system accounts with four modules: of knowledge, the student model, of tutor and of interface, basic characteristics that allows to locate this system in the context of the intelligent tutorial systems. In this system in particular, the knowledge module was only modified, because advantage is taken of the existing structure to incorporate a new dominion of application: the one of the techniques of tuning of control systems. The system maintains the characteristic that it can also be used as a consultation system. In addition to the design and validation of the tutorial system, when following the methodology of processing the degree of generality of the developed system, was evaluated, taking into account the evaluation and quantification of metrics that the engineering software proposes. [Spanish] En este trabajo se describen el diseno, el desarrollo y la validacion de un sistema tutorial inteligente orientado a la instruccion de tecnicas de sintonizacion de sistemas de control. Este sistema esta basado en sistemas desarrollados anteriormente en la Unidad de Simulacion del Instituto de Investigaciones Electricas (IIE). El sistema disenado cuenta con cuatro modulos: de conocimiento, del modelo del estudiante, de tutor y de interfaz, caracteristica principal que permite ubicar a este sistema en el contexto de los sistemas tutoriales inteligentes. En este sistema en particular solo se modifica el modulo de conocimiento, pues se aprovecha la estructura existente para incorporar un nuevo dominio de aplicacion: el de las tecnicas de sintonizacion de sistemas de control. El sistema mantiene la caracteristica de que tambien puede utilizarse como un sistema de

  6. Required ozone doses for removing pharmaceuticals from wastewater effluents

    DEFF Research Database (Denmark)

    Antoniou, Maria; Hey, Gerly; Rodríguez Vega, Sergio

    2013-01-01

    of each investigated API (DDO3) was determined for each effluent by fitting a first order equation to the remaining concentration of API at each applied ozone dose. Ozone dose requirements were found to vary significantly between effluents depending on their matrix characteristics.The specific ozone dose...... was then normalized to the dissolved organic carbon (DOC) of each effluent. The DDO3/DOC ratios were comparable for each API between the effluents.15 of the 42 investigated APIs could be classified as easily degradable (DDO3/DOC≤0.7), while 19 were moderately degradable (0.71.4). Furthermore, we predict...... that a reasonable estimate of the ozone dose required to remove any of the investigated APIs may be attained by multiplying the experimental average DDO3/DOC obtained with the actual DOC of any effluent....

  7. Facility effluent monitoring plan for the tank farms facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bachand, D.D.; Crummel, G.M.

    1995-05-01

    A facility effluent monitoring plan is required by the US Department of Energy for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using specific guidelines. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years.

  8. Performance of drippers in two filtering systems using sewage treatment effluent

    Directory of Open Access Journals (Sweden)

    Alexandre B. Dalri

    Full Text Available ABSTRACT The objective of this study was to evaluate the performance of three models of drippers using treated sewage effluent, pure and diluted, and two types of filters, screen and disc. The treated sewage effluent used in the experiment was collected from the city’s treatment plant. The experiment included 12 lateral lines with three types of emitters to apply pure (100% and diluted (50% effluent filtered by screen and disc filters. The combination of those factors set the treatments: T1 (50% effluent diluted in fresh water filtered by a screen filter; T2 (50% effluent diluted in fresh water filtered by a disc filter; T3 (pure effluent filtered by a screen filter; T4 (pure effluent filtered by a disc filter. The results showed that the flat type emitter is less sensitive to clogging, the disc filter is the most suitable to prevent clogging and the use of pure or diluted sewage effluent increases the drippers’ flow rate coefficient of variation.

  9. Bioremediation of petroleum refinery effluent by Planococcus ...

    African Journals Online (AJOL)

    In the present investigation, Planococcus halophilus was screened for hydrocarbon degradation and bioremediation of refinery effluent. The test organism, P. halophilus, showed the capability to utilize kerosene as carbon source in minimal medium. Biological treatment of the refinery effluent with P. halophilus reduced the ...

  10. Evolución estelar en sistemas binarios

    Science.gov (United States)

    De Vito, M. A.; Benvenuto, O.

    Definición y clasificación de sistemas binarios; descripción del comportamiento del sistema frente a la variación de su masa; binarias de rayos X; transferencia de masa en sistemas binarios masivos aplicado al posible esclarecimiento del progenitor azul de la supernova SN 1987A; comentario acerca de la evolución de enanas blancas de helio de baja masa y su conexión con los sistemas binarios; reseña del trabajo de Kippenhahn y Weigert sobre el cual está basado el código evolutivo desarrollado en la FCAG por el Dr. Benvenuto y sobre el cual se trabajará para poder incluir la evolución de una estrella con pérdida de masa perteneciente a un sistema binario.

  11. Assessing Methanobrevibacter smithii and Clostridium difficile as not conventional faecal indicators in effluents of a wastewater treatment plant integrated with sludge anaerobic digestion.

    Science.gov (United States)

    Romanazzi, Valeria; Bonetta, Silvia; Fornasero, Stefania; De Ceglia, Margherita; Gilli, Giorgio; Traversi, Deborah

    2016-12-15

    Wastewater treatment plants (WWTP) are an important source of surface water contamination by enteric pathogens, affecting the role of environmental water as a microbial reservoir. We describe the release to the environment of certain anaerobes of human and environmental concern. The work was focused on emerging microbial targets. They are tracing, by RT-qPCR, on WWTP effluents, both liquid and solid, when an anaerobic digestion step is included. The focus is placed on Clostridium spp. with the specific quantification of Clostridium perfringens, as typical bioindicator, and Clostridium difficile, as emerging pathogen not only confined into nosocomial infection. Moreover methanogens were quantified for their involvement in the anaerobic digestion, and in particular on Methanobrevibacter smithii as major methanogenic component of the human gut microbiome and as not conventional faecal indicator. In the water samples, a reduction, statistically significant, in all microbial targets was observed (p effluents, particularly bio-solids, to reduce the potential release of pathogens into the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Economic valuation of environmental benefits of removing pharmaceutical and personal care products from WWTP effluents by ozonation.

    Science.gov (United States)

    Molinos-Senante, M; Reif, R; Garrido-Baserba, M; Hernández-Sancho, F; Omil, F; Poch, M; Sala-Garrido, R

    2013-09-01

    Continuous release of pharmaceutical and personal care products (PPCPs) present in effluents from wastewater treatment plants (WWTPs) is nowadays leading to the adoption of specific measures within the framework of the Directive 2000/60/EC (Water Framework Directive). The ozonation process, normally employed for drinking water production, has also proven its potential to eliminate PPCPs from secondary effluents in spite of their low concentrations. However, there is a significant drawback related with the costs associated with its implementation. This lack of studies is especially pronounced regarding the economic valuation of the environmental benefits associated to avoid the discharge of these pollutants into water bodies. For the first time the shadow prices of 5 PPCPs which are ethynilestradiol, sulfamethoxazole, diclofenac, tonalide and galaxolide from treated effluent using a pilot-scale ozonation reactor have been estimated. From non-sensitive areas their values are -73.73; -34.95; -42.20; -10.98; and -8.67 respectively and expressed in €/kg. They represent a proxy to the economic value of the environmental benefits arisen from undischarged pollutants. This paper contributes to value the environmental benefits of implementing post-treatment processes aimed to achieve the quality standards required by the Priority Substances Directive. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Europe-wide survey of estrogenicity in wastewater treatment plant effluents: the need for the effect-based monitoring.

    Science.gov (United States)

    Jarošová, Barbora; Erseková, Anita; Hilscherová, Klára; Loos, Robert; Gawlik, Bernd M; Giesy, John P; Bláha, Ludek

    2014-09-01

    A pan-European monitoring campaign of the wastewater treatment plant (WWTP) effluents was conducted to obtain a concise picture on a broad range of pollutants including estrogenic compounds. Snapshot samples from 75 WWTP effluents were collected and analysed for concentrations of 150 polar organic and 20 inorganic compounds as well as estrogenicity using the MVLN reporter gene assay. The effect-based assessment determined estrogenicity in 27 of 75 samples tested with the concentrations ranging from 0.53 to 17.9 ng/L of 17-beta-estradiol equivalents (EEQ). Approximately one third of municipal WWTP effluents contained EEQ greater than 0.5 ng/L EEQ, which confirmed the importance of cities as the major contamination source. Beside municipal WWTPs, some treated industrial wastewaters also exhibited detectable EEQ, indicating the importance to investigate phytoestrogens released from plant processing factories. No steroid estrogens were detected in any of the samples by instrumental methods above their limits of quantification of 10 ng/L, and none of the other analysed classes of chemicals showed correlation with detected EEQs. The study demonstrates the need of effect-based monitoring to assess certain classes of contaminants such as estrogens, which are known to occur at low concentrations being of serious toxicological concern for aquatic biota.

  14. Experimental and numerical simulations of the hydrodynamic dispersion of a pollutant effluent in a estuarine coastal zone

    International Nuclear Information System (INIS)

    Gidas, N.K.; Koutitonsky, V.G.

    1996-01-01

    An experimental and numerical study was performed to measure and simulate the hydrodynamic dispersion of a pollutant effluent discharged by an outfall diffuser into an estuarine coastal zone near Rimouski, Canada. Field measurements of currents, tides, salinity, and winds were obtained in the vicinity of the injection site, and two tracer dispersion experiments were carried on in these coastal waters. The measurements were taken before and after the construction of the marine outfall diffuser. The similitude between the plume of a tracer (physical model) released into the coastal waters before construction and that of the real effluent (prototype) discharged at the same site was studied. A new coefficient of similitude was established, which allows to transpose the concentrations of the physical model tracer to the waste water concentrations of the prototype. The numerical simulation (2D) is performed with a hydrodynamic model and an advection-dispersion model of the MIKE21 system from the Danish Hydraulic Institute, using the so-called telescopic approach. The objective of these simulations was to predict, among other things, the pollutant effluent concentrations for critical hydrodynamic conditions relative to the aquatic ecosystem to be protected. The methodology elaborated was used for the management of the coastal environments subjected to pollution. (author). 28 refs., 2 tabs., 12 figs

  15. Sistema inteligente de detección de intrusiones

    OpenAIRE

    Martínez Puentes, Javier

    2011-01-01

    El sistema diseñado es un sistema de detección de intrusiones mediante el análisis del payload del tráfico de la red en busca de algún tipo de malware. Este sistema implementa su algoritmo de detección como “preprocesador dinámico” de Snort. Mediante el trabajo conjunto de Snort y del Sistema diseñado puede afirmarse que se obtiene un sistema altamente eficaz ante ataques conocidos (mediante el paso de reglas de Snort) e igualmente eficaz ante ataques nuevos o desconocidos (que era el obj...

  16. Nuclear power plants and the environment. Water samplings and releases

    International Nuclear Information System (INIS)

    Hartmann, Philippe; Bordet, Francois; Chevalier, Christian; Colin, Jean-Luc; Khalanski, Michel

    2013-01-01

    This voluminous and illustrated guide aims at giving detailed information on the nature of waters used by nuclear power plants and of releases, on how these samplings and controls are performed, on the associated risks for the environment and public health, and on how public is informed. After a general overview of these issues, a chapter addresses the protection of nature and biodiversity and the actions performed by EDF in this respect. The next chapter deals with public information. The next chapters discuss the water needs of a nuclear power plant, effluent releases and their impacts. Two chapters are dedicated to the monitoring and control of the environment, and to the various techniques of environmental metrology. Legal and regulatory aspects are then presented

  17. The effluent problem in a plutonium production centre

    International Nuclear Information System (INIS)

    Galley, R.; Cantel, J.

    1960-01-01

    The first part of the report is devoted to generalities: the geographical situation of the Marcoule Centre, the sources of radio-active effluent, methods of treating this effluent. In the second part the authors gives a detailed description of the various installations in the Radio-active Effluent Treatment Station at the Marcoule Centre, and outline the conditions governing the rejection of treated effluent into the Rhone. A few lines are given to comparisons between the results obtained from the use of these installations up till may 1959 and the expected results published by the same authors at the Brussels Conference (1956). In conclusion the authors lay down some of the essential principles, applicable to the study of new installations. (author) [fr

  18. Electrocoagulation for the treatment of textile industry effluent--a review.

    Science.gov (United States)

    Khandegar, V; Saroha, Anil K

    2013-10-15

    Various techniques such as physical, chemical, biological, advanced oxidation and electrochemical are used for the treatment of industrial effluent. The commonly used conventional biological treatment processes are time consuming, need large operational area and are not effective for effluent containing toxic elements. Advanced oxidation techniques result in high treatment cost and are generally used to obtain high purity grade water. The chemical coagulation technique is slow and generates large amount of sludge. Electrocoagulation has recently attracted attention as a potential technique for treating industrial effluent due to its versatility and environmental compatibility. This technique uses direct current source between metal electrodes immersed in the effluent, which causes the dissolution of electrode plates into the effluent. The metal ions, at an appropriate pH, can form wide range of coagulated species and metal hydroxides that destabilize and aggregate particles or precipitate and adsorb the dissolved contaminants. Therefore, the objective of the present manuscript is to review the potential of electrocoagulation for the treatment of industrial effluents, mainly removal of dyes from textile effluent. © 2013 Elsevier Ltd. All rights reserved.

  19. Introducción al estudio de los sistemas económicos

    OpenAIRE

    García Nossa, Antonio

    2010-01-01

    Interdependencia de los sistemas; Coexistencia de los sistemas; Sucesión y coexistencia; Sistemas históricos y sistemas geopolíticos; Factores cuantitativos y cualitativos de los sistemas; Principios generales de los sistemas.

  20. The influence of agro-industrial effluents on River Nile pollution

    Directory of Open Access Journals (Sweden)

    Sayeda M. Ali

    2011-01-01

    Full Text Available The major agro-industrial effluents of sugarcane and starch industries pose a serious threat to surface waters. Their disposal in the River Nile around Cairo city transitionally affected the microbial load. In situ bacterial enrichment (50–180% was reported and gradually diminished downstream; the lateral not vertical effect of the effluent disposal was evident. Disposed effluents increased BOD and COD, and then progressively decreased downstream. Ammoniacal N was elevated, indicating active biological ammonification and in situ biodegradability of the effluents. In vitro, the nitrogen-fixing rhizobacteria Crysomonas luteola, Azospirillum spp., Azomonas spp. and K. pneumoniae successfully grew in batch cultures prepared from the crude effluents. This was supported by adequate growth parameters and organic matter decomposition. Therefore, such biodegradability of the tested agro-industrial effluents strongly recommends their use for microbial biomass necessary for the production of bio-preparates.

  1. Physiochemical Treatment of Textile Industry Effluents

    International Nuclear Information System (INIS)

    Latif, M. I.; Qazi, M. A.; Khan, H.; Ahmad, N.

    2015-01-01

    The study mainly focuses on the application of chemical Coagulants (Lime, Alum and Ferrous Sulfate) and Advanced Oxidation Processes (AOPs) (Ozone Treatment and Fenton Process, alone and in combination) to treat textile industry effluents, optimization of coagulation process for various Coagulants in terms of process conditions, including coagulant dose, pH and settling time. The results revealed that Alum was most effective. The efficiency of coagulation process was dose dependent and 400 mg/L dose of Alum alone showed maximum color removal of 47%, 57% and 54% of yellow, red and blue dyes, respectively in addition to the COD removal of 44%. The combined applications of Alum and Lime (300:75 mg/L) and Lime and Alum (300:75 mg/L) showed slightly better COD removal of 51%. However, color removal efficiency of all coagulants was at par. The Ozonation process appeared the most promising for the treatment of waste water and color/COD removal, the efficiency of which increased with increasing the treatment time at constant Ozone dose. For less polluted effluents, 97% color removal was obtained after 1 minute and after 15 minutes for highly polluted effluents; The COD removal efficiency of the process for less polluted effluents was around 89% after 5 minutes Ozonation and for highly polluted effluents 88% COD removal after 40 minutes. The performance of Fenton process was extremely low as compared to Ozonation process. Increase in pH, significantly decreased the color removal efficiency of the process. COD removal efficiency of Fenton process increased with an increase in settling time. (author)

  2. Wastewater effluent dispersal in Southern California Bays

    KAUST Repository

    Uchiyama, Yusuke; Idica, Eileen Y.; McWilliams, James C.; Stolzenbach, Keith D.

    2014-01-01

    The dispersal and dilution of urban wastewater effluents from offshore, subsurface outfalls is simulated with a comprehensive circulation model with downscaling in nested grid configurations for San Pedro and Santa Monica Bays in Southern California during Fall of 2006. The circulation is comprised of mean persistent currents, mesoscale and submesoscale eddies, and tides. Effluent volume inflow rates at Huntington Beach and Hyperion are specified, and both their present outfall locations and alternative nearshore diversion sites are assessed. The effluent tracer concentration fields are highly intermittent mainly due to eddy currents, and their probability distribution functions have long tails of high concentration. The dilution rate is controlled by submesoscale stirring and straining in tracer filaments. The dominant dispersal pattern is alongshore in both directions, approximately along isobaths, over distances of more than 10. km before dilution takes over. The current outfall locations mostly keep the effluent below the surface and away from the shore, as intended, but the nearshore diversions do not. © 2014 Elsevier Ltd.

  3. Wastewater effluent dispersal in Southern California Bays

    KAUST Repository

    Uchiyama, Yusuke

    2014-03-01

    The dispersal and dilution of urban wastewater effluents from offshore, subsurface outfalls is simulated with a comprehensive circulation model with downscaling in nested grid configurations for San Pedro and Santa Monica Bays in Southern California during Fall of 2006. The circulation is comprised of mean persistent currents, mesoscale and submesoscale eddies, and tides. Effluent volume inflow rates at Huntington Beach and Hyperion are specified, and both their present outfall locations and alternative nearshore diversion sites are assessed. The effluent tracer concentration fields are highly intermittent mainly due to eddy currents, and their probability distribution functions have long tails of high concentration. The dilution rate is controlled by submesoscale stirring and straining in tracer filaments. The dominant dispersal pattern is alongshore in both directions, approximately along isobaths, over distances of more than 10. km before dilution takes over. The current outfall locations mostly keep the effluent below the surface and away from the shore, as intended, but the nearshore diversions do not. © 2014 Elsevier Ltd.

  4. Order of the 4 March 2014 on the homologation of the decision nr 2014-DC-4016 of the Nuclear Safety Authority of the 16 January 2014 defining the limits of releases in the environment of liquid and gaseous effluents by the basic nuclear installations nr 124, 125, 126 and 137 exploited by EDF-SA in Cattenom (Moselle district)

    International Nuclear Information System (INIS)

    Durand, J.M.

    2014-01-01

    This order issued by the French Ministry of ecology, sustainable development and energy is based on a decision taken by the ASN. It concerns the management of pollutions and of the impact of a nuclear installation on the environment: applicable limits of gaseous (notably carbon 14, tritium, rare gases, iodines), chemical, and liquid effluent release. Tables indicate the maximum concentrations

  5. Environmental radiological surveillance in perspective: the relative importance of environmental media as a function of effluent pathway and radionuclides

    International Nuclear Information System (INIS)

    Denham, D.H.

    1977-10-01

    Most published guidelines for environmental surveillance emphasize the collection and analysis of specific media (e.g. air, water, milk, direct radiation) without total regard for the potential dose impact of the radionuclides expected in or actually present in the effluent streams from nuclear facilities. To determine the relative importance of medium/nuclide combinations in environmental surveillance, the experience at major ERDA sites and at operating nuclear power plants was reviewed. Typical release rates for nuclide groupings (tritium, noble gases, radioiodine, mixed fission or activation products, and transuranics) in those effluent streams were followed through various environmental pathways. By using this scheme the environmental medium which is most prominent in the critical dose pathway to man was determined. It was also possible to determine points of short-or long-term contaminant accumulation. Following these calculations, each medium was ranked for a given nuclide/effluent pathway combination providing the relative importance of sampling specific environmental media with emphasis on the radiation dose to a critical population group. Finally, the results of these environmental pathway studies are presented in tabular form to provide ready reference for environmental surveillance program design or evaluation

  6. Complete physico-chemical treatment for coke plant effluents.

    Science.gov (United States)

    Ghose, M K

    2002-03-01

    Naturally found coal is converted to coke which is suitable for metallurgical industries. Large quantities of liquid effluents produced contain a large amount of suspended solids, high COD, BOD, phenols, ammonia and other toxic substances which are causing serious pollution problem in the receiving water to which they are discharged. There are a large number of coke plants in the vicinity of Jharia Coal Field (JCF). Characteristics of the effluents have been evaluated. The present effluent treatment systems were found to be inadequate. Physico-chemical treatment has been considered as a suitable option for the treatment of coke plant effluents. Ammonia removal by synthetic zeolite, activated carbon for the removal of bacteria, viruses, refractory organics, etc. were utilized and the results are discussed. A scheme has been proposed for the complete physico-chemical treatment, which can be suitably adopted for the recycling, reuse and safe disposal of the treated effluent. Various unit process and unit operations involved in the treatment system have been discussed. The process may be useful on industrial scale at various sites.

  7. Performance analysis in stepped solar still for effluent desalination

    Energy Technology Data Exchange (ETDEWEB)

    Velmurugan, V. [Department of Mechanical Engineering, Infant Jesus College of Engineering, Thoothukudi, Tamil Nadu 628 851 (India); Naveen Kumar, K.J.; Noorul Haq, T.; Srithar, K. [Department of Mechanical Engineering, Thiagarajar College of Engineering, Madurai, Tamil Nadu 625 015 (India)

    2009-09-15

    In this work, a stepped solar still and an effluent settling tank are fabricated and tested for desalinating the textile effluent. The effluent is purified in an effluent settling tank. In this tank, large and fine solid particles are settled and clarified. The settled effluents are used as raw water in the stepped solar still. For better performance, the stepped solar still consists of 50 trays with two different depths. First 25 trays with 10 mm height and the next 25 trays with 5 mm height are used. Fin, sponge, pebble and combination of the above are used for enhancing the productivity of the stepped solar still. A maximum increase in productivity of 98% occurs in stepped solar still when fin, sponge and pebbles are used in this basin. Theoretical analysis agrees well with experimental results. (author)

  8. UNC Nuclear Industries reactor and fuels production facilities. 1984 effluent release report

    International Nuclear Information System (INIS)

    Rokkan, D.J.

    1985-01-01

    This document has been prepared to fulfill the annual reporting requirements of DOE 5484.1, ''Environmental Protection, Safety, and Health Protection Information Reporting Requirements.'' Radioanalyses performed on routine samples of liquid and airborne streams were evaluated using UNC's Environmental Release Summary computer program. All identified significant discharges from UNC facilities to the environment during CY 1984 are reported in this document

  9. El Sistema inspirerede projekter

    DEFF Research Database (Denmark)

    Holst, Finn; Chemi, Tatiana

    Rapporten er resultat af pilotprojektet ”Forundersøgelse El Sistema DK” gennemført af Ph.D. Finn Holst (DPU, Aarhus Universitet) og Ph.D. Tatiana Chemi (Aalborg Universitet) i 2015. I rapporten indgår desuden bidrag fra Sofie Holm, Sara Fink Søndergaard og Stine Møgelbjerg Johansen. Pilotprojektet...... er gennemført for DMKLs El Sistema-udvalg med støtte fra Statens Kunstfond, Projektstøtteudvalget for Musik....

  10. Sistema fotovoltaico de iluminación solar

    OpenAIRE

    Víctor Hugo Benítez Baltazar; Guadalupe Araceli Torres Valverde; Luis Armando Gámez Valdéz; Jesús Horacio Pacheco Ramírez

    2013-01-01

    El artículo es el resultado de un trabajo de investigación enfocado al uso de sistemas fotovoltaicos para la iluminación por medio de diodos emisores de luz tipo LED. Se busca reducir el consumo energético mediante la implementación de un sistema de iluminación basado en LED hasta en un 80%, donde la fuente primaria de energía es el Sol. Se demuestra la viabilidad de los sistemas solares de iluminación LED mediante la construcción de un prototipo. Los sistemas de iluminación fotovoltaicos son...

  11. Combined environmental stress from shrimp farm and dredging releases in a subtropical coastal lagoon (SE Gulf of California).

    Science.gov (United States)

    Cardoso-Mohedano, J G; Páez-Osuna, F; Amezcua-Martínez, F; Ruiz-Fernández, A C; Ramírez-Reséndiz, G; Sanchez-Cabeza, J A

    2016-03-15

    Nutrient pollution causes environmental damages on aquatic ecosystems worldwide. Eutrophication produces impacts in coastal ecosystems, affecting biota and ecosystem services. The Urias coastal lagoon (SE Gulf of California) is a sub-tropical estuary under several environmental pressures such as nutrient inputs from shrimp farm effluents and dredging related to port operations, which can release substances accumulated in sediments. We assessed the water quality impacts caused by these activities and results showed that i) nitrogen was the limiting nutrient, ii) shrimp farm effluents increased particulate organic matter and chlorophyll a in the receiving stations, and iii) dredging activities increased nitrite and reduced dissolved oxygen concentrations. The co-occurrence of the shrimp farm releases and dredging activities was likely the cause of a negative synergistic effect on water quality which mainly decreases dissolved oxygen and increases nitrite concentrations. Coastal zone management should avoid the co-occurrence of these, and likely others, stressors in coastal ecosystems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. 200 Area TEDF effluent sampling and analysis plan

    International Nuclear Information System (INIS)

    Alaconis, W.C.; Ballantyne, N.A.; Boom, R.J.

    1995-06-01

    This sampling analysis sets forth the effluent sampling requirements, analytical methods, statistical analyses, and reporting requirements to satisfy the State Waste Discharge Permit No. ST4502 for the Treated Effluent Disposal Facility. These requirements are listed below: Determine the variability in the effluent of all constituents for which enforcement limits, early warning values and monitoring requirements; demonstrate compliance with the permit; and verify that BAT/AKART (Best Available Technology/All know and Reasonable Treatment) source, treatment, and technology controls are being met

  13. Immanuel Wallerstein e o moderno sistema mundial

    Directory of Open Access Journals (Sweden)

    José Jobson de Andrade Arruda

    1983-12-01

    Full Text Available (primeiro parágrafo do texto Immanuel Wallerstein é diretor do Centro Fernand Braudel para o Estudo de Economias, Sistemas Históricos e Civilizacionais (Binghamton, N.Y. e editor da revista trimestral Review. Seu projeto mais amplo é a busca dos elementos determinantes do sistema mundial moderno. Para tanto, dividiu o seu trabalho em quatro partes principais, às quais con-sidera as quatro épocas fundamentais apresentadas pelo dito sistema até hoje. O primeiro volume, objeto desta resenha crítica, cobre o período de 1450 a 1640, correspondendo ao estudo das origens e condições primitivas do sistema mundial até então exclusivamente um sistema europeu. O segundo volume, já publicado, ocupar-se-ia da consolidação do sis-tema entre 1640 e 1815. O terceiro volume, referente ao período de 1815 a 1917, estará centrado na recriação do sistema decorrente das vertiginosas transformações resultantes do dinamismo tecnológico e do avanço do industrialismo no século XIX. O quarto volume cuidará da consolidação da economia — mundo capitalista, a partir de 1917 até a atualidade, e das tensões "revolucionárias" particulares que esta conso lidação tem provocado.

  14. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M J; Levien, R [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F G; Rodrigues, N R [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A I.P.

    1994-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  15. Plant and soil modifications by continuous surface effluent application

    Energy Technology Data Exchange (ETDEWEB)

    Tedesco, M.J.; Levien, R. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Dept. of Solos; Mohrdieck, F.G.; Rodrigues, N.R. [CORSAN-SITEL, Triunfo, RS (Brazil). Polo Petroquimico do Sul. Dept. de Operacao e Manutencao; Flores, A.I.P.

    1993-12-31

    In order to study the effects on soil and plants of the liquid effluent generated by a the Integrated Liquid Effluent Treatment System of a large Brazilian petrochemical complex, a field study was conducted in four areas which received the effluent and compared to control sites. This work presents some results of this study. 12 refs., 1 fig., 3 tabs.

  16. In-Plant Corrosion Study of Steels in Distillery Effluent Treatment Plant

    Science.gov (United States)

    Ram, Chhotu; Sharma, Chhaya; Singh, A. K.

    2015-05-01

    The present study deals with corrosion and performance of steels observed in an effluent treatment plant (ETP) of a distillery. For this purpose, the metal coupons were exposed in primary (untreated effluent) and secondary tank (anaerobic treatment effluent) of the ETP. The extent of attack has been correlated with the composition of the effluent with the help of laboratory immersion and electrochemical tests. Untreated distillery effluent found to be more corrosive than the anaerobic-treated effluents and is assigned due to chloride, phosphate, calcium, nitrate, and nitrite ions, which enhances corrosivity at acidic pH. Mild steel showed highest uniform and localized corrosion followed by stainless steels 304L and 316L and lowest in case of duplex 2205.

  17. Facility effluent monitoring plan determinations for the 200 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-11-01

    The following facility effluent monitoring plan determinations document the evaluations conducted for the Westinghouse Hanford Company 200 Area facilities (chemical processing, waste management, 222-S Laboratory, and laundry) on the Hanford Site in south central Washington State. These evaluations determined the need for facility effluent monitoring plans for the 200 Area facilities. The facility effluent monitoring plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438 (WHC 1991). The Plutonium/Uranium Extraction Plant and UO 3 facility effluent monitoring plan determinations were prepared by Los Alamos Technical Associates, Richland, Washington. The Plutonium Finishing Plant, Transuranic Waste Storage and Assay Facility, T Plant, Tank Farms, Low Level Burial Grounds, and 222-S Laboratory determinations were prepared by Science Applications International Corporation of Richland, Washington. The B Plant Facility Effluent Monitoring Plan Determination was prepared by ERCE Environmental Services of Richland, Washington

  18. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Lohrasbi, J.; Johnson, D.L.; De Lorenzo, D.S.

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  19. Facility effluent monitoring plan for the plutonium uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  20. Facility effluent monitoring plan for the plutonium uranium extraction facility

    International Nuclear Information System (INIS)

    Wiegand, D.L.

    1994-09-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years

  1. Facility effluent monitoring plan for the Plutonium Uranium Extraction Facility

    International Nuclear Information System (INIS)

    Greager, E.M.

    1997-01-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan will ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, at a minimum, every 3 years

  2. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    Energy Technology Data Exchange (ETDEWEB)

    Lohrasbi, J.; Johnson, D.L. [Westinghouse Hanford Co., Richland, WA (United States); De Lorenzo, D.S. [Los Alamos Technical Associates, NM (United States)

    1993-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-01. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated at a minimum of every three years.

  3. Control óptimo y robusto H∞ de sistemas no lineales aplicaciones a sistemas electromecánicos

    OpenAIRE

    Vivas Venegas, Carlos

    2004-01-01

    La teoría de control automático ha experimentado un notable desarrollo en los últimos tiempos especialmente en el campo de los sistemas no lineales. Son aportaciones relativamente recientes los paradigmas de control basados en pasividad, teoría de sistema

  4. Estabilización robusta de sistemas lineales

    Directory of Open Access Journals (Sweden)

    Horacio Leyva Castellanos

    2013-12-01

    Full Text Available En este trabajo se muestra un conjunto de resultados que permiten abordar el problema de la estabilización robusta de una familia de sistemas lineales positivos. Se describen dos nuevas aplicaciones en la teoría de control positivo para sistemas compartimentales y se muestra la aplicación de un teorema de robustez para tales sistemas

  5. Evaluation of the cytogenotoxicity of textile effluents using Allium cepa L.

    Directory of Open Access Journals (Sweden)

    Sandro Barbosa

    2011-08-01

    Full Text Available The cytotoxic and genotoxic potential of the raw (EB and treated (ET effluents of two textile mills located in south of Minas Gerais State that have their effluents treated at the same Effluent Treatment Plant was investigated using the Allium cepa test system. Cytotoxicity was evaluated by the root elongation and mitotic index (MI endpoints and the genotoxicity was assessed by de determination of chromosome aberrations (CA.The effluent samples were tested at the concentrations 0 (ultrapure water, 25, 50, 75, and 100 % (v/v. A Completely Randomized Design with four replicates of 30 seeds was used. The effluent samples in almost all tested concentrations promoted an increase in root elongation compared to the negative control and this effect was probably related to nutrients levels and organic matter in effluent samples. A lower MI at all concentrations of ET compared to EB. The highest MI was observed at 100% (v/v concentration of both effluents. The highest rates of CA occurred at concentrations 75% (v/v of EB and 100% (v/v of both effluents. The effluent samples showed no cytotoxic effect, but cell division occurred disorderly, leading to increase rate of AC, revealing a genetoxic effect. Improvements in the wastewater treatment are needed to reduce environmental impacts.

  6. Elimination of effluents and wastes contaminated by radionuclides produced in installations authorized on the account of the Public Health Code - ASN guide nr 18 - Release of the 26/01/2012

    International Nuclear Information System (INIS)

    2012-01-01

    This document aims at specifying the modalities of application of a decision taken by the ASN in January 2008 regarding the technical rules which the elimination of effluents and wastes contaminated by radionuclides must comply with. First, it describes the objective of the 'waste zoning' concept. Then, it addresses the management of contaminated wastes: general rules, wastes contaminated by radionuclides of very short period (less than 100 days) and of period longer than 100 days, and the management of wastes with 'hybrid risks'. It addresses the management of contaminated effluents: radioactive liquid effluent with a period either shorter or longer than 100 days, radioactive gaseous effluents. It addresses the warehousing conditions (premise design, exploitation rules). The other parts deal with the convention between several establishments within a same site (notably in the case of nuclear medicine departments), with the management plan, and with the agenda for the implementation of the ASN decision

  7. Coal washery effluent treatment for material recovery and water reuse

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, N.N.; Chaudhuri, M.

    1980-10-01

    Th effluent from coal washeries consisting mainly of coal fines is normally discharged to inland surface waters and causes severe river pollution with substantial loss of good quality coking coal. The study reported in this paper was undertaken to characterize the effluents from several coal washeries and to evaluate the potential of using various coagulants and coagulant aids for clarification of the effluent with a view to recovery of the coal fines and reuse of the clarified effluent. It has been demonstrated that higher recovery of coal fines can be achieved by using coagulants like alum or ferric chloride with or without coagulant aids with an added advantage of reuse of the clarified effluent in the washery.

  8. Overexpression of antibiotic resistance genes in hospital effluents over time.

    Science.gov (United States)

    Rowe, Will P M; Baker-Austin, Craig; Verner-Jeffreys, David W; Ryan, Jim J; Micallef, Christianne; Maskell, Duncan J; Pearce, Gareth P

    2017-06-01

    Effluents contain a diverse abundance of antibiotic resistance genes that augment the resistome of receiving aquatic environments. However, uncertainty remains regarding their temporal persistence, transcription and response to anthropogenic factors, such as antibiotic usage. We present a spatiotemporal study within a river catchment (River Cam, UK) that aims to determine the contribution of antibiotic resistance gene-containing effluents originating from sites of varying antibiotic usage to the receiving environment. Gene abundance in effluents (municipal hospital and dairy farm) was compared against background samples of the receiving aquatic environment (i.e. the catchment source) to determine the resistome contribution of effluents. We used metagenomics and metatranscriptomics to correlate DNA and RNA abundance and identified differentially regulated gene transcripts. We found that mean antibiotic resistance gene and transcript abundances were correlated for both hospital ( ρ  = 0.9, two-tailed P  hospital effluent samples. High β-lactam resistance gene transcript abundance was related to hospital antibiotic usage over time and hospital effluents contained antibiotic residues. We conclude that effluents contribute high levels of antibiotic resistance genes to the aquatic environment; these genes are expressed at significant levels and are possibly related to the level of antibiotic usage at the effluent source. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy.

  9. Evaporation behaviour of different organic effluents from open surfaces.

    Science.gov (United States)

    Jhorar, B S; Malik, R S

    1993-01-01

    Production of large quantities of effluents from different industrial units and the problems of their disposal necessitated this evaporation study. The evaporation of water, sewage water, oil refinery effluent, papermill effluent and liquor distillery effluent was observed in glass beakers when placed (i) in an oven at 60 degrees C and (ii) in screen house for 30 days, by periodically weighing of the beakers. In other experiments, the effect of increasing the frequency of stirring on increasing the evaporation efficiency of the liquor distillery effluent (ELD) was examined in detail. All of the organic effluents except ELD had similar evaporation behaviours as water, but formation of a self-forming film caused the evaporation of ELD to be considerably lower. Resistance to evaporation caused by this film was found to be a decreasing function of the frequency of stirring. This study has a bearing on improving the efficiency of evaporation lagoons, and three stirrings in a day with a manually drawn stirrer in a full-scale lagoon are proposed as a practical and economically viable technique to save 44% of lagoon land in arid and semi-arid regions of the world.

  10. 200 Area Effluent Treatment Facility: Delisting petition

    International Nuclear Information System (INIS)

    1993-08-01

    Waste water has been generated for over 40 years as a result of operations conducted on the Hanford Site. This waste water previously was discharged to cribs, ponds, or ditches. An example of such waste water includes process condensate that might have been in contact with dangerous waste or mixed waste (containing both radioactive and dangerous components). This petition presents the treatment technologies that are designed into the 200 Area Effluent Treatment Facility to eliminate the dangerous characteristics of the waste and to delist the effluent in accordance with the requirements found in 40 Code of Federal Regulations 260.20 and 260.22. The purpose of this petition is to demonstrate that the 242-A Evaporator process condensate will be treated adequately so that the effluent from the 200 Area Effluent Treatment Facility will no longer require management as a regulated dangerous waste. This demonstration was performed by use of a surrogate (synthetic) waste, designed by the US Department of Energy, Richland Operations Office to include species that represent all organic and inorganic constituents (but not radionuclide species) expected to be found on the Hanford Site. Thus, the surrogate will encompass not only the expected 242-A Evaporator process condensate characteristics, but those of other potential 200 Area Effluent Treatment Facility waste streams and additional 40 CFR Appendix VIII constituents

  11. Handling effluent from nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Allen, G.C.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the different methods to handle effluent from nuclear thermal propulsion system ground tests

  12. Concept and approaches used in assessing individual and collective doses from releases of radioactive effluents

    International Nuclear Information System (INIS)

    1988-06-01

    To guide on the applications of the principles for limiting radioactive releases contained in Safety Series 77, the Agency is in the process of preparing a number of safety guides. The first one is this present document which deals with the principal aspects of the methods for the assessment of the individual and collective dose. It aims at giving a general guidance to those responsible for establishing programmes for the determination of individual doses as well as collective doses in connection with licensing a site for a nuclear installation. The document is concerned with the principles applied for calculating individual and collective doses from routine releases of radionuclides to the atmosphere and hydrosphere but not releases directly to the geosphere, as in waste management. These areas will be covered by other Agency publications. 75 refs, figs and tabs

  13. Techniques to limit gaseous releases in case of reactor accident. Choice criteria - present solutions

    International Nuclear Information System (INIS)

    Billard, Francois; Lavie, Jean-Marie

    1964-10-01

    Within the frame of the study of radiological risks associated with a reactor accident in order to define the required responses, this study comprises, on the one hand, an analysis of the different accident types in order to select typical accidents, and on the other hand, a site-based analysis to define the maximum admissible radioactivity release for a given site. The determination of minimum required coefficient of risk reduction results from a compromise between the choice of reactor configuration type and the efficiency of purification devices, while taking into account minimum characteristics of the enclosure mechanical strength, local release conditions, and nature of gaseous effluents to be processed. After a review of available containment techniques, the author applies this analysis method to the different French reactor types. He gives a brief description of adopted solutions for the most typical French reactors in terms of characteristics of venting and filtration devices. As data quality is a crucial requirement, the author outlines the need for further studies regarding fission product emission and transfer, the purification of gaseous effluents and their diffusion in the atmosphere [fr

  14. Facility effluent monitoring plan for the plutonium-uranium extraction facility

    International Nuclear Information System (INIS)

    Thompson, R.J.; Sontage, S.

    1991-11-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan is the first annual report. It shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated as a minimum every three years

  15. Microbiologia de sistema de lodos ativados e sua relação com o tratamento de efluentes industriais: a experiência da Cetrel Activated sludge system microbiology and its relationship with the industrial effluents treatment: the experience of the Cetrel

    Directory of Open Access Journals (Sweden)

    Gisele Santos Silva de Oliveira

    2009-06-01

    Full Text Available Buscou-se, neste trabalho, caracterizar a comunidade microbiana de lodos ativados dos tanques de aeração (TA-2, TA-3 e TA-4 da estação de tratamento de efluentes (ETE da Cetrel e correlacioná-la com parâmetros físico-químicos de processo, bem como avaliar o impacto do efluente industrial (EI bruto na estrutura da comunidade do lodo. Adicionalmente, foi verificada a existência de possíveis correlações entre a qualidade do efluente tratado final (ETF e a comunidade do lodo para identificar algum grupo biológico que pudesse ser usado como bioindicador desta ETE. Os principais grupos encontrados nos TA foram ciliados (livre natantes, de vida livre e pedunculados e flagelados. Verificou-se que altas cargas de DBO e DQO no EI afetam negativamente o sistema, especialmente o grupo dos ciliados, que foram os melhores indicadores da elevada eficiência da ETE. O TA-2 mostrou ser o tanque mais estável e eficiente.The purpose of this study was to characterize the microbial community of activated sludge in the aeration tanks (AT-2, AT-3 and AT-4 from the Cetrel wastewater treatment plant (WWTP and to correlate it to physical-chemical parameters, as well as to assess the impact of the raw industrial effluent (IE on the activated sludge community. Additionally, it was verified the relationship between the treated effluent (TE quality and the biological groups to determinate indicators of the WWTP efficiency. Ciliated protozoa (free-swimming, crawler and sessile and flagellates were the main biological groups found in the TA. It was demonstrated that high IE-BOD and -COD loads have a negative influence on the system, especially on the ciliated protozoa, which was the best indicator of high efficiency of the WWTP. The AT-2 was the more stable and efficient.

  16. [Newly Designed Water Treatment Systems for Hospital Effluent].

    Science.gov (United States)

    Azuma, Takashi

    2018-01-01

     Pharmaceuticals are indispensable to contemporary life. Recently, the emerging problem of pharmaceutical-based pollution of river environments, including drinking water sources and lakes, has begun to receive significant attention worldwide. Because pharmaceuticals are designed to perform specific physiological functions in targeted regions of the human body, there is increasing concern regarding their toxic effects, even at low concentrations, on aquatic ecosystems and human health, via residues in drinking water. Pharmaceuticals are consistently employed in hospitals to treat disease; and Japan, one of the most advanced countries in medical treatment, ranks second worldwide in the quantity of pharmaceuticals employed. Therefore, the development of technologies that minimize or lessen the related environmental risks for clinical effluent is an important task as well as that for sewage treatment plants (STPs). However, there has been limited research on clinical effluent, and much remains to be elucidated. In light of this, we are investigating the occurrence of pharmaceuticals, and the development of water treatment systems for clinical effluent. This review discusses the current research on clinical effluent and the development of advanced water treatment systems targeted at hospital effluent, and explores strategies for future environmental risk assessment and risk management.

  17. Electrochemical Corrosion Investigations on Anaerobic Treated Distillery Effluent

    Science.gov (United States)

    Ram, Chhotu; Sharma, Chhaya; Singh, A. K.

    2014-09-01

    Present study is focused on the corrosivity of anaerobic treated distillery effluent and corrosion performance of mild steel and stainless steels. Accordingly, electrochemical polarization tests were performed in both treated distillery and synthetic effluents. Polarization tests were also performed in synthetic solutions and it was observed that Cl- and K+ increase whereas SO4 -, PO4 -, NO3 -, and NO2 - decrease the corrosivity of effluent at alkaline pH. Further, comparison in corrosivity of distillery and synthetic effluents shows the former to be less corrosive and this is assigned due to the presence of amino acids and melanoidins. Mild steel experienced to have the highest corrosion rate followed by stainless steels—304L and 316L and lowest in case of SAF 2205. Relative corrosion resistance of stainless steels is observed to depend upon Cr, Mo, and N content.

  18. Detoxification of kraft pulp ECF bleaching effluents by catalytic hydrotreatment.

    Science.gov (United States)

    Calvo, L; Gilarranz, M A; Casas, J A; Mohedano, A F; Rodríguez, J J

    2007-02-01

    Two different effluents from the D(1) and E(1) stages of the ECF bleaching of Eucalyptus globulus kraft pulp were treated by catalytic hydrogenation in a trickle bed reactor using commercial and homemade Pd/AC catalysts. The reactor was fed with the bleaching effluent and a H(2)/N(2) gas stream. The variables studied were space-time (1.4-5g(cat)min/mL), gas to liquid flow ratio (286-1000vol.), gas feed concentration (H(2):N(2), 1:1-1:7.3vol.), temperature (25-100 degrees C) and pressure (1-11bar). Hydrotreatment performance was evaluated in terms of ecotoxicity, adsorbable organic halogen (AOX), chemical oxygen demand (COD), biological oxygen demand (BOD(5)) and colour removal. In all the runs, the ecotoxicity of the effluents decreased as a result of the treatment, achieving reductions that ranged from 70% to 98%. Simultaneously to the reduction of toxicity, the hydrotreatment led to a decrease of the colour of the effluents, being the decrease significantly higher in the case of E(1) effluent. The AOX content was reduced by 85% and 23% for E(1) and D(1) effluents, respectively. In the case of D(1) effluent the removal of ecotoxicity was significantly higher than that of AOX, which indicates that much of the toxicity of the effluent must be associated to non-chlorinated organics. In spite of the important reduction of ecotoxicity, the biodegradability of the effluents only increased slightly. The homemade catalysts, prepared from activated carbons with a high external or non-microporous surface area and mesopore volume and a convenient surface chemistry showed a higher efficiency than the commercial one.

  19. Treated Effluent Disposal Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Treated non-hazardous and non-radioactive liquid wastes are collected and then disposed of through the systems at the Treated Effluent Disposal Facility (TEDF). More...

  20. Utilization of vinasse effluents from an anaerobic reactor

    Energy Technology Data Exchange (ETDEWEB)

    Costa, F J.C.B.; Rocha, B B.M.; Viana, C E; Toledo, A C

    1986-01-01

    An anaerobic reactor was developed to biodigest alcohol distillery wastes. A further post-treatment of the effluent reduced the level of pollution to the point of eventually discharging into streams and rivers. The present work also analyses the use of biodigested vinasse as a source of food for fish. Very high efficiencies were obtained during primary and secondary treatment of vinasse effluent, as demonstrated by the greatly reduced organic load. The utilization of the treated effluent as a source of fish food presents an excellent alternative for the Brazilian alcohol industry. (Refs. 6).

  1. Diversity of marine invertebrates in a thermal effluent

    International Nuclear Information System (INIS)

    Logan, D.T.; Maurer, D.

    1975-01-01

    Invertebrates were collected at four sites in the Indian River and Indian River Bay in Delaware to study the effects of thermal effluents from a steam-generating plant. A list of species of anemones, nemerteans, annelids, molluscs, and crustaceans is presented. Differences in species composition, an increase in relative numbers of a pollution indicator organism, and reduction in species number and in the total number of organisms in the effluent were noted. The period of highest diversity corresponded to that of the lowest numbers of species and individuals and highest effluent temperatures. (U.S.)

  2. Pollution from tanneries effluents and its impact on environment

    International Nuclear Information System (INIS)

    Rajput, A.A.; Memon, Hafeez-ur-Rahman; Sahto, M.H.

    1999-01-01

    The disposal of tanneries effluence has become one of the serious environmental problems. The effluents from tanneries contain highly toxic materials, including chromium salts, ammonium salts, acids, sodium sulphide and suspended solids. Hair, alkalinity, surfactants, dyes and oils are also present in these effluents. The extent of pollution depends upon the volume of the effluent discharged. Many studies have been carried out on the characteristics of these effluents in order to understand the nature of the effluents and their impact on environment. The present study shows measured values of different parameters like Biochemical Oxygen Demand (BOD) about 1950 mg/l, Chemical Oxygen Demand (COD) about 4500-4600 mg/l, suspended solids about 2600-2700 mg/l, dissolved solids 10000-12000 mg/l and lead, copper, chromium and cadmium about 2, 0.4, 64.4 and 0.31 mg/l respectively. The measured values are compared with that of previous. Some remedial measures for its treatment and disposal are also discussed. (author)

  3. The use of artificial wetlands to treat greenhouse effluents

    OpenAIRE

    Lévesque, Vicky; Dorais, Martine; Gravel, Valérie; Ménard, Claudine; Antoun, Hani; Rochette, Philippe; Roy, Stéphane

    2011-01-01

    Untreated greenhouse effluents or leak solution constitute a major environmental burden because their nitrate and phosphate concentrations may induce eutrophication. Artificial wetlands may offer a low cost alternative treatment of greenhouse effluents and consequently improve the sustainability of greenhouse growing systems. The objectives of this study were to 1) characterize the efficiency of different types of wetland to reduce ion content of greenhouse tomato effluent, and 2) improve the...

  4. Clean technologies: methods for minimizing the releases and choice of the effluents valorization processes. Application to metal workshops; Technologies propres: methodes de minimisation des rejets et de choix des procedes de valorisation des effluents. Application aux ateliers de traitement de surface

    Energy Technology Data Exchange (ETDEWEB)

    Laforest, V.

    1999-12-10

    Currently, the essential part of the money invested by the industrialist is for the water treatment. In France, most of the 20 billions francs per year devoted to the water treatment is used for the industrial activity. The global management of effluents favour the integration of clean technologies (optimization, change and modification of the production process) in order to reduce the pollution problem at its source. Our study aims at the introduction of clean technologies in the metal workshops (consumer and generator of water and chemicals) by the development of two data management methods, which lead to two decision support systems. The aim of the first one is to minimize both the water consumption and the wastewater disposal by optimizing the production process (optimum yield and efficiency of the rinsing baths). The second one concerns the choice of valorization techniques considering the valorization objectives, the effluents characteristics and the parameters limiting the use of the techniques. Our approach fits into a global management method for the metal finishing industry wastewater. Its aim is to limit the quantity of wastewater generated, to valorize effluents and by this way to develop the clean technologies.

  5. Screening for crude oil degrading bacteria in liquid organic waste (effluent samples)

    International Nuclear Information System (INIS)

    Akpe, A.R.

    2014-01-01

    The screening for crude oil degrading bacteria in some liquid organic wastes (cassava mill effluents, rubber effluents and oil palm mill effluents) was carried out. Hydrocarbon utilising bacteria were isolated on mineral salt agar using vapour phase technique. The samples yielded 20 bacterial isolates from 13 different genera. Cassava mill effluent and rubber effluent had the highest number (7), while oil palm effluent had the least number (6) of bacterial isolates. The isolates that had the highest occurrence (occurring in all samples) were Pseudomonas aeruginosa and Escherichia coli. Of these 13 genera 9 were gram negative, while only 4 were gram positive. The total heterotrophic bacterial (THB) count and total hydrocarbon utilisers (THU) from all the effluent samples ranged from 3.0 * 10/sup 4/ to 6.0* 10/sup 7/ cfu/mL and 2.3 *10/sup 2/ to 4.2*10/sup 3/ cfu/mL, respectively. The counts of hydrocarbon utilisers were obviously lower than the heterotrophic counts, although the differences in counts were found to be statistically non-significant (P > 0.05). Rubber effluents and oil palm mill effluents had the highest number of hydrocarbon utilisers with three isolates each. The active hydrocarbon utilisers encountered in this study included Serratia marscescens, Bacillus cereus, P. aeruginosa, Enterobacter aerogenes and Bacillus subtilis. Presence of nutrients and crude oil degrading bacteria in these effluents suggests that these effluents can be used to enhance bioremediation through their use as biostimulation and bioaugmentation agents. (author)

  6. Methods for determining the release of radioactive material into the environment

    International Nuclear Information System (INIS)

    Farges, L.; Daw, H.T.

    1976-01-01

    The current policy on the discharge of radioactive effluents calls for the containment of radioactive wastes in most instances. The resulting doses to individuals and populations have been shown by many surveys to be very small (UNSCEAR Report, 1972). Nevertheless, small amounts of radioactive releases are made to the environment during normal operation of nuclear facilities. Whenever discharge of radioactive effluents to the environment is permitted, careful consideration is made of all the relevant factors which might lead to exposure of man. However, with the expansion of nuclear power programmes, more sophistication is required in setting discharge limits to the environment, taking into consideration future sources as well as present sources. The IAEA's recommendations conform to the dose limitation system set out by the International Commission on Radiological Protection (ICRP). The system implies that the individual dose limits should never be exceeded. Furthermore, the ICRP guidelines require that doses be kept as low as reasonably possible, taking social and economic considerations into account. This second objective, usually called optimization, implies the use of differential cost-benefit analysis. At present, decisions are still made by other procedures, for example, by applying safety factors to release limits derived only from the dose limits. However, the ICRP system of dose limitation, including optimization, appears to be a more rational approach to the establishment of release limits. Thus, it is necessary to provide basic material on concepts which are intended for use and decision making by national authorities, and the Agency plans to publish a series of complementary documents on the application of these concepts to various specific cases. (author)

  7. Methanization of industrial liquid effluents

    International Nuclear Information System (INIS)

    Frederic, S.; Lugardon, A.

    2007-01-01

    In a first part, this work deals with the theoretical aspects of the methanization of the industrial effluents; the associated reactional processes are detailed. The second part presents the technological criteria for choosing the methanization process in terms of the characteristics of the effluent to be treated. Some of the methanization processes are presented with their respective advantages and disadvantages. At last, is described the implementation of an industrial methanization unit. The size and the main choices are detailed: the anaerobic reactor, the control, the valorization aspects of the biogas produced. Some examples of industrial developments illustrate the different used options. (O.M.)

  8. The application of XML in the effluents data modeling of nuclear facilities

    International Nuclear Information System (INIS)

    Yue Feng; Lin Quanyi; Yue Huiguo; Zhang Yan; Zhang Peng; Cao Jun; Chen Bo

    2013-01-01

    The radioactive effluent data, which can provide information to distinguish whether facilities, waste disposal, and control system run normally, is an important basis of safety regulation and emergency management. It can also provide the information to start emergency alarm system as soon as possible. XML technology is an effective tool to realize the standard of effluent data exchange, in favor of data collection, statistics and analysis, strengthening the effectiveness of effluent regulation. This paper first introduces the concept of XML, the choices of effluent data modeling method, and then emphasizes the process of effluent model, finally the model and application are shown, While there is deficiency about the application of XML in the effluents data modeling of nuclear facilities, it is a beneficial attempt to the informatization management of effluents. (authors)

  9. Radiological safety system based on real-time tritium-in-air monitoring indoors and in effluents

    International Nuclear Information System (INIS)

    Bidica, N.; Sofalca, N; Balteanu, O.; Srefan, I.

    2006-01-01

    Exposure to tritium is an important health hazard in any tritium processing facility so that implementing a real-time tritium monitoring system is necessary for its operation in safety conditions. The tritium processing facility operators need to be informed at any time about the in-air tritium concentration indoors or in the stack effluents, in order to detect immediately any leaks in tritium containments, or any releases inside the buildings or to the environment. This information is very important for adopting if necessary protection measures and correcting actions as quickly as possible. In this paper we describe an improved real-time tritium monitoring system designed for the Heavy Water Detritiation Pilot Plant of National Institute for Cryogenics and Isotopes Separation, Rm. Valcea, Romania. The design of the Radiological Safety System implemented for the ICIT Water Detritiation Pilot Plant is intended to provide the maximum safety level based on the ALARA concept. The main functions of tritium monitoring system are: - monitoring the working areas and gaseous effluents by determination of the tritium-in-air activity concentration; - local and remote data display; - assessing of environment dose equivalent rates and dose equivalents in the working environment (for personnel exposure control and work planning); - assessing the total tritium activity released to the environment through ventilation exhaust stack; - safety functions, i.e., local and remote, locking/unlocking personnel access, process shut-down in emergency conditions and start of the air cleaning systems. With all these features our tritium monitoring system is really a safety system adequate for personnel and environmental protection. (authors)

  10. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    Energy Technology Data Exchange (ETDEWEB)

    Shoucheng, Wen [Yangtze Univ., HuBei Jingzhou (China)

    2014-02-15

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%.

  11. Petroleum Refinery Effluents Treatment by Advanced Oxidation Process with Methanol

    International Nuclear Information System (INIS)

    Shoucheng, Wen

    2014-01-01

    Petroleum refinery effluents are waste originating from industries primarily engaged in refining crude oil. It is a very complex compound of various oily wastes, water, heavy metals and so on. Conventional processes are unable to effectively remove the chemical oxygen demand (COD) of petroleum refinery effluents. Supercritical water oxidation (SCWO) was proposed to treat petroleum refinery effluents. In this paper, methanol was used to investigate co-oxidative effect of methanol on petroleum refinery effluents treatment. The results indicated that supercritical water oxidation is an effective process for petroleum refinery effluents treatment. Adding methanol caused an increase in COD removal. When reaction temperature is 440 .deg. C, residence time is 20 min, OE is 0.5 and initial COD is 40000 mg/L, and COD removal increases 8.5%

  12. Cyanobacterial flora from polluted industrial effluents.

    Science.gov (United States)

    Parikh, Amit; Shah, Vishal; Madamwar, Datta

    2006-05-01

    Effluents originating from pesticides, agro-chemicals, textile dyes and dyestuffs industries are always associated with high turbidity, colour, nutrient load, and heavy metals, toxic and persistent compounds. But even with such an anthropogenic nature, these effluents contain dynamic cyanobacterial communities. Documentation of cyanobacterial cultures along the water channels of effluents discharged by above mentioned industries along the west coast of India and their relationship with water quality is reported in this study. Intensity of pollution was evaluated by physico-chemical analysis of water. Higher load of solids, carbon and nutrients were found to be persistent throughout the analysis. Sediment and water samples were found to be colored in nature. Cyanobacterial community structure was found to be influenced by the anthropogenic pollution. 40 different cyanobacterial species were recorded from 14 genera of 5 families and an elevated occurrence of Phormidium, Oscillatoria and Chroococcus genera was observed in all the sampling sites.

  13. Feasibility of using geothermal effluents for waterfowl wetlands

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-09-01

    This project was conducted to evaluate the feasibility of using geothermal effluents for developing and maintaining waterfowl wetlands. Information in the document pertains to a seven State area the West where geothermal resources have development potential. Information is included on physiochemical characteristics of geothermal effluents; known effects of constituents in the water on a wetland ecosystem and water quality criteria for maintaining a viable wetland; potential of sites for wetland development and disposal of effluent water from geothermal facilities; methods of disposal of effluents, including advantages of each method and associated costs; legal and institutional constraints which could affect geothermal wetland development; potential problems associated with depletion of geothermal resources and subsidence of wetland areas; potential interference (adverse and beneficial) of wetlands with ground water; special considerations for wetlands requirements including size, flows, and potential water usage; and final conclusions and recommendations for suitable sites for developing demonstration wetlands.

  14. Fast microbial reduction of ferrihydrite colloids from a soil effluent

    Science.gov (United States)

    Fritzsche, Andreas; Bosch, Julian; Rennert, Thilo; Heister, Katja; Braunschweig, Juliane; Meckenstock, Rainer U.; Totsche, Kai U.

    2012-01-01

    Recent studies on the microbial reduction of synthetic iron oxide colloids showed their superior electron accepting property in comparison to bulk iron oxides. However, natural colloidal iron oxides differ in composition from their synthetic counterparts. Besides a potential effect of colloid size, microbial iron reduction may be accelerated by electron-shuttling dissolved organic matter (DOM) as well as slowed down by inhibitors such as arsenic. We examined the microbial reduction of OM- and arsenic-containing ferrihydrite colloids. Four effluent fractions were collected from a soil column experiment run under water-saturated conditions. Ferrihydrite colloids precipitated from the soil effluent and exhibited stable hydrodynamic diameters ranging from 281 (±146) nm in the effluent fraction that was collected first and 100 (±43) nm in a subsequently obtained effluent fraction. Aliquots of these oxic effluent fractions were added to anoxic low salt medium containing diluted suspensions of Geobacter sulfurreducens. Independent of the initial colloid size, the soil effluent ferrihydrite colloids were quickly and completely reduced. The rates of Fe2+ formation ranged between 1.9 and 3.3 fmol h-1 cell-1, and are in the range of or slightly exceeding previously reported rates of synthetic ferrihydrite colloids (1.3 fmol h-1 cell-1), but greatly exceeding previously known rates of macroaggregate-ferrihydrite reduction (0.07 fmol h-1 cell-1). The inhibition of microbial Fe(III) reduction by arsenic is unlikely or overridden by the concurrent enhancement induced by soil effluent DOM. These organic species may have increased the already high intrinsic reducibility of colloidal ferrihydrite owing to quinone-mediated electron shuttling. Additionally, OM, which is structurally associated with the soil effluent ferrihydrite colloids, may also contribute to the higher reactivity due to increasing solubility and specific surface area of ferrihydrite. In conclusion, ferrihydrite

  15. EDO, Doses to Man and Organs from Reactor Operation Noble Gas and Liquid Waste Release

    International Nuclear Information System (INIS)

    Rodenas Diago, Jose; Serradell Garcia, Vicente

    1983-01-01

    1 - Description of problem or function: EDO evaluates individual and collective doses to man from atmospheric releases of noble gases and other gaseous effluents. 2 - Method of solution: The dose calculations are carried out by following the guide- lines of USNRC Regulatory Guide 1.109. Radiation exposure for maximum individuals and population are estimated within 30 km from the nuclear plant. This area is divided into 160 circular trapezoids, to which computations are referred. Four age groups, seven organs for internal dose and two for external dose have been considered. Dose calculations are done through 14 pathways, 7 for liquid effluents, one for noble gases, and 6 for the rest of gaseous effluents. 3 - Restrictions on the complexity of the problem: The following are the maximum dimension sizes preset in the code: 73 radionuclides (other than noble gases); 15 noble gases; 160 circular trapezoids; 31 chemical elements; 4 types of aquatic foods; 15 points of exposure for shorelines; 15 trapezoids influenced by each point; 4 terrestrial food pathways; 100 centres of population. Some of these limits can be varied

  16. EDO, Doses to Man and Organs from Reactor Operation Noble Gas and Liquid Waste Release

    Energy Technology Data Exchange (ETDEWEB)

    Rodenas Diago, Jose; Serradell Garcia, Vicente [Departamento de Ingenieria Nuclear, Escuela Tecnica Superior de Ingenieros Industriales, Universidad Politecnica, Camino de Vera 2/n Apartado 2012, Valencia (Spain)

    1983-10-18

    1 - Description of problem or function: EDO evaluates individual and collective doses to man from atmospheric releases of noble gases and other gaseous effluents. 2 - Method of solution: The dose calculations are carried out by following the guide- lines of USNRC Regulatory Guide 1.109. Radiation exposure for maximum individuals and population are estimated within 30 km from the nuclear plant. This area is divided into 160 circular trapezoids, to which computations are referred. Four age groups, seven organs for internal dose and two for external dose have been considered. Dose calculations are done through 14 pathways, 7 for liquid effluents, one for noble gases, and 6 for the rest of gaseous effluents. 3 - Restrictions on the complexity of the problem: The following are the maximum dimension sizes preset in the code: 73 radionuclides (other than noble gases); 15 noble gases; 160 circular trapezoids; 31 chemical elements; 4 types of aquatic foods; 15 points of exposure for shorelines; 15 trapezoids influenced by each point; 4 terrestrial food pathways; 100 centres of population. Some of these limits can be varied.

  17. Release of hepatic Plasmodium yoelii merozoites into the pulmonary microvasculature.

    Directory of Open Access Journals (Sweden)

    Kerstin Baer

    2007-11-01

    Full Text Available Plasmodium undergoes one round of multiplication in the liver prior to invading erythrocytes and initiating the symptomatic blood phase of the malaria infection. Productive hepatocyte infection by sporozoites leads to the generation of thousands of merozoites capable of erythrocyte invasion. Merozoites are released from infected hepatocytes as merosomes, packets of hundreds of parasites surrounded by host cell membrane. Intravital microscopy of green fluorescent protein-expressing P. yoelii parasites showed that the majority of merosomes exit the liver intact, adapt a relatively uniform size of 12-18 microm, and contain 100-200 merozoites. Merosomes survived the subsequent passage through the right heart undamaged and accumulated in the lungs. Merosomes were absent from blood harvested from the left ventricle and from tail vein blood, indicating that the lungs effectively cleared the blood from all large parasite aggregates. Accordingly, merosomes were not detectable in major organs such as brain, kidney, and spleen. The failure of annexin V to label merosomes collected from hepatic effluent indicates that phosphatidylserine is not exposed on the surface of the merosome membrane suggesting the infected hepatocyte did not undergo apoptosis prior to merosome release. Merosomal merozoites continued to express green fluorescent protein and did not incorporate propidium iodide or YO-PRO-1 indicating parasite viability and an intact merosome membrane. Evidence of merosomal merozoite infectivity was provided by hepatic effluent containing merosomes being significantly more infective than blood with an identical low-level parasitemia. Ex vivo analysis showed that merosomes eventually disintegrate inside pulmonary capillaries, thus liberating merozoites into the bloodstream. We conclude that merosome packaging protects hepatic merozoites from phagocytic attack by sinusoidal Kupffer cells, and that release into the lung microvasculature enhances the

  18. Occurrence of disinfection byproducts in United States wastewater treatment plant effluents

    KAUST Repository

    Krasner, Stuart W.; Westerhoff, Paul K.; Chen, Baiyang; Rittmann, Bruce E.; Amy, Gary L.

    2009-01-01

    Effluents from wastewater treatment plants (WWTPs) contain disinfection byproducts (DBPs) of health concern when the water is utilized downstream as a potable water supply. The pattern of DBP formation was strongly affected by whether or not the WWTP achieved good nitrification. Chlorine addition to poorly nitrified effluents formed low levels of halogenated DBPs, except for (in some cases) dihalogenated acetic acids, but often substantial amounts of N-nitrosodimethyamine (NDMA). Chlorination of well-nitrified effluent typically resulted in substantial formation of halogenated DBPs but much less NDMA. For example, on a median basis after chlorine addition, the well-nitrified effluents had 57 μg/L of trihalomethanes [THMs] and 3 ng/L of NDMA, while the poorly nitrified effluents had 2 μg/L of THMs and 11 ng/L of NDMA. DBPs with amino acid precursors (haloacetonitriles, haloacetaldehydes) formed at substantial levels after chlorination of well-nitrified effluent. The formation of halogenated DBPs but not that of NDMA correlated with the formation of THMs in WWTP effluents disinfected with free chlorine. However, THM formation did not correlate with the formation of other DBPs in effluents disinfected with chloramines. Because of the relatively high levels of bromide in treated wastewater, bromine incorporation was observed in various classes of DBPs. © 2009 American Chemical Society.

  19. Occurrence of disinfection byproducts in United States wastewater treatment plant effluents

    KAUST Repository

    Krasner, Stuart W.

    2009-11-01

    Effluents from wastewater treatment plants (WWTPs) contain disinfection byproducts (DBPs) of health concern when the water is utilized downstream as a potable water supply. The pattern of DBP formation was strongly affected by whether or not the WWTP achieved good nitrification. Chlorine addition to poorly nitrified effluents formed low levels of halogenated DBPs, except for (in some cases) dihalogenated acetic acids, but often substantial amounts of N-nitrosodimethyamine (NDMA). Chlorination of well-nitrified effluent typically resulted in substantial formation of halogenated DBPs but much less NDMA. For example, on a median basis after chlorine addition, the well-nitrified effluents had 57 μg/L of trihalomethanes [THMs] and 3 ng/L of NDMA, while the poorly nitrified effluents had 2 μg/L of THMs and 11 ng/L of NDMA. DBPs with amino acid precursors (haloacetonitriles, haloacetaldehydes) formed at substantial levels after chlorination of well-nitrified effluent. The formation of halogenated DBPs but not that of NDMA correlated with the formation of THMs in WWTP effluents disinfected with free chlorine. However, THM formation did not correlate with the formation of other DBPs in effluents disinfected with chloramines. Because of the relatively high levels of bromide in treated wastewater, bromine incorporation was observed in various classes of DBPs. © 2009 American Chemical Society.

  20. Liquid Effluent Retention Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Liquid Effluent Retention Facility (LERF) is located in the central part of the Hanford Site. LERF is permitted by the State of Washington and has three liquid...

  1. Effects of effluent water on the abundance of cowpea insect pests.

    Science.gov (United States)

    Tiroesele, Bamphitlhi; Sitwane, Monametsi; Obopile, M; Ullah, Muhammad Irfan; Ali, Sajjad

    2017-10-03

    Botswana experiences low and unreliable rainfall. Thus, the use of effluent water in agriculture is increasingly important. Insect damage is the major constraint for cowpea grain production in the most cowpea-producing lands. We investigated the effects of effluent water on insect pest abundance on cowpea (Vigna unguiculata) under field conditions. The experiment was laid out in a randomized complete block design with 100, 75, 50, and 25% of effluent water and 0% (control-clean tap water) treatments. Treatments with 100% effluent water resulted in a significant increase in insect pest populations as compared with the control. These results show that the use of effluent water to irrigate crops may increase incidence, abundance, and damage caused by insect pests possibly by decreasing plant vigor. The use of effluent water in agriculture should be addressed in a wise way.

  2. Biochemical methane potential of kraft bleaching effluent and codigestion with other in-mill streams

    DEFF Research Database (Denmark)

    Fitamo, Temesgen Mathewos; Dahl, Olli; Master, Emma

    2016-01-01

    and in combination: total bleaching effluent, alkaline bleaching effluent, kraft evaporator condensate, and chemithermomechanical pulping effluent. The total bleaching effluent, consisting of the chlorine dioxide bleaching and alkaline bleaching effluents, exhibited the highest potential for organic matter...

  3. Chromium removal from tanning industries effluents

    International Nuclear Information System (INIS)

    Chaudry, M.A.; Ahmad, S.

    1997-01-01

    Air and water are the basic needs of human being and other living entities on the earth. Tanning industry uses water and some chemicals and so creates environmental problems, depending basically on two principal sources, hide and water. The processes of tanning are based on chromium sulphate and vegetable treatment of hide. According to the national environmental quality standards (NEQS) the effluent or disposed water should contain phenol less than 0.5 ppm, Cr, sulphates, chloride and other salts content. About 30-40 liters of water are used to process one Kg of raw hide into finished goods. Total installed capacity of hides and skins chrome tanning is 53.5 million square meter, earning a large amount of foreign exchange for our country. In the present work, seven tanning industries effluents from the suburbs of Multan city have been collected and analysed. The pH of the liquors have been found to vary from 2.72 to 4.4 and the constituent Cr have been found to be from zero to 8000 ppm from vegetable to chrome tanning industrial effluents studied. The stages involved in tanning and treatment of the effluent water waste including chemical treatment of Cr has been described with a special reference to supported liquid membranes process for removal of chromium ions. (author)

  4. Facility effluent monitoring plan for the 327 Facility

    International Nuclear Information System (INIS)

    1994-11-01

    The 327 Facility [Post-Irradiation Testing Laboratory] provides office and laboratory space for Pacific Northwest Laboratory (PNL) scientific and engineering staff conducting multidisciplinary research in the areas of post-irradiated fuels and structural materials. The facility is designed to accommodate the use of radioactive and hazardous materials in the conduct of these activities. This report summarizes the airborne emissions and liquid effluents and the results of the Facility Effluent Monitoring Plan (FEMP) determination for the facility. The complete monitoring plan includes characterization of effluent streams, monitoring/sampling design criteria, a description of the monitoring systems and sample analysis, and quality assurance requirements

  5. Guide for effluent radiological measurements at DOE installations

    International Nuclear Information System (INIS)

    Corley, J.P.; Corbit, C.D.

    1983-07-01

    Effluent monitoring and reporting programs are maintained at all US Department of Energy (DOE) facilities that may: (1) discharge significant concentrations of radioactivity in relation to applicable standards, or (2) discharge quantities of radioactivity that have potential health and safety or other environmental significance. This Guide is intended to provide supplemental guidance to DOE Orders on methods, procedures, and performance criteria to bring more comparable rationale to DOE facility effluent measurement programs and promote compliance with applicable standards and provide the DOE Office of Operational Safety (OOS) and Operations Offices with an additional tool for evaluating effluent measurement programs at DOE facilities

  6. Radioactive effluents from CANDU 6 reactors during normal operation

    International Nuclear Information System (INIS)

    Boss, C.R.; Allsop, P.J.

    1995-12-01

    During routine operation of a CANDU 6 reactor, various gaseous, liquid, and solid radioactive wastes are generated. The layout of the CANDU 6 reactor and the design of its systems ensure that these are minimized, but small quantities of gaseous and liquid wastes are continually discharged at very low concentrations. This report discusses the make-up of these chronically generated gaseous and liquid effluents. From a safety perspective, the doses to individual members of the public resulting from radioactive wastes chronically discharged from CANDU 6 reactors have been negligible. Similarly, doses to the regional and global populations have been negligible, generally less than 0.001% of background. While far below regulatory limits, releases of tritium, noble gases and gross β - -γ have been the most radiologically significant emissions, while radioiodine and particulates have had the greatest potential to deliver public dose. (author). 8 refs., 16 tabs., 3 figs

  7. Nutrient Release from Disturbance of Infiltration System Soils during Construction

    Directory of Open Access Journals (Sweden)

    Daniel P. Treese

    2012-01-01

    Full Text Available Subsurface infiltration and surface bioretention systems composed of engineered and/or native soils are preferred tools for stormwater management. However, the disturbance of native soils, especially during the process of adding amendments to improve infiltration rates and pollutant removal, may result in releases of nutrients in the early life of these systems. This project investigated the nutrient release from two soils, one disturbed and one undisturbed. The disturbed soil was collected intact, but had to be air-dried, and the columns repacked when soil shrinkage caused bypassing of water along the walls of the column. The undisturbed soil was collected and used intact, with no repacking. The disturbed soil showed elevated releases of nitrogen and phosphorus compared to the undisturbed soil for approximately 0.4 and 0.8 m of runoff loading, respectively. For the undisturbed soil, the nitrogen release was delayed, indicating that the soil disturbance accelerated the release of nitrogen into a very short time period. Leaving the soil undisturbed resulted in lower but still elevated effluent nitrogen concentrations over a longer period of time. For phosphorus, these results confirm prior research which demonstrated that the soil, if shown to be phosphorus-deficient during fertility testing, can remove phosphorus from runoff even when disturbed.

  8. Facility effluent monitoring plan determinations for the 400 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-09-01

    This Facility Effluent Monitoring Plan determination resulted from an evaluation conducted for the Westinghouse Hanford Company 400 Area facilities on the Hanford Site. The Facility Effluent Monitoring Plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans. Two major Westinghouse Hanford Company facilities in the 400 Area were evaluated: the Fast Flux Test Facility and the Fuels Manufacturing and examination Facility. The determinations were prepared by Westinghouse Hanford Company. Of these two facilities, only the Fast Flux Test Facility will require a Facility Effluent Monitoring Plan. 7 refs., 5 figs., 4 tabs

  9. Atrial natriuretic peptide stimulates salt secretion by shark rectal gland by releasing VIP

    Energy Technology Data Exchange (ETDEWEB)

    Silva, P.; Stoff, J.S.; Solomon, R.J.; Lear, S.; Kniaz, D.; Greger, R.; Epstein, F.H.

    1987-01-01

    Salt secretion by the isolated perfused rectal gland of the spiny dogfish shark, Squalus acanthias, is stimulated by synthetic rat atrial natriuretic peptide (ANP II) as well as extracts of shark heart, but not by 8-bromo-cyclic guanosine 5'-monophosphate. Cardiac peptides have no effect on isolated rectal gland cells or perfused tubules, suggesting that stimulation requires an intact gland. The stimulation of secretion by ANP II is eliminated by maneuvers that block neurotransmitter release. Cardiac peptides stimulate the release of vasoactive intestinal peptide (VIP), known to be present in rectal glands nerves, into the venous effluent of perfused glands in parallel with their stimulation of salt secretion, but the release of VIP induced by ANP II is prevented by perfusion with procaine. VIP was measured by radioimmunoassay. Cardiac peptides thus appear to regulate rectal gland secretion by releasing VIP from neural stores within the gland. It is possible that other physiological effects of these hormones might be explained by an action to enhanced local release of neurotransmitters.

  10. Atrial natriuretic peptide stimulates salt secretion by shark rectal gland by releasing VIP

    International Nuclear Information System (INIS)

    Silva, P.; Stoff, J.S.; Solomon, R.J.; Lear, S.; Kniaz, D.; Greger, R.; Epstein, F.H.

    1987-01-01

    Salt secretion by the isolated perfused rectal gland of the spiny dogfish shark, Squalus acanthias, is stimulated by synthetic rat atrial natriuretic peptide (ANP II) as well as extracts of shark heart, but not by 8-bromo-cyclic guanosine 5'-monophosphate. Cardiac peptides have no effect on isolated rectal gland cells or perfused tubules, suggesting that stimulation requires an intact gland. The stimulation of secretion by ANP II is eliminated by maneuvers that block neurotransmitter release. Cardiac peptides stimulate the release of vasoactive intestinal peptide (VIP), known to be present in rectal glands nerves, into the venous effluent of perfused glands in parallel with their stimulation of salt secretion, but the release of VIP induced by ANP II is prevented by perfusion with procaine. VIP was measured by radioimmunoassay. Cardiac peptides thus appear to regulate rectal gland secretion by releasing VIP from neural stores within the gland. It is possible that other physiological effects of these hormones might be explained by an action to enhanced local release of neurotransmitters

  11. Facility effluent monitoring plan for the 2724-W Protective Equipment Decontamination Facility

    International Nuclear Information System (INIS)

    Nickels, J.M.; Lavey, G.H.

    1992-12-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation requires the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  12. Effluent treatment efficiency and compliance monitoring in Nigerian ...

    African Journals Online (AJOL)

    The effectiveness of effluent treatment at the Eleme Petrochemical Industry, Port Harcourt, Nigeria was monitored weekly for six weeks to assess their level of compliance with the Directorate of Petroleum Resources (DPR) guidelines and standards for environmental safety. Effluent samples were taken from the untreated ...

  13. LABCORE post release 1.0 development system project management plan

    International Nuclear Information System (INIS)

    Rich, H.S.

    1994-01-01

    The LABCORE post release 1.0 development system project management plan (SPMP) is the primary planning document governing the development of specific enhancements to the LABCORE project. The mission of the Westinghouse Hanford Company (WHC) laboratories is changing from supporting the 200 Area chemical processing plants for process control, waste management, and effluent monitoring to supporting environmental restoration and regulatory compliance commitments. The LABCORE program was implemented as the key element for meeting the commitments by upgrading the laboratories through the implementation of an Automated Data Processing improvement program in January 1994. Scope for LABCORE release 1.0 consisted of hardware and software implementation required to support a minimum number of analyses (Single-Shell Tank [SST] analysis at 222S Laboratory and Performance Evaluation samples at the Waste Sampling Characterization Facility laboratory) using manual entry of data, and to support routine laboratory functions, common to all laboratories. LABCORE post release 1.0 enhancements will expand the functionality presented to the laboratory. Post release 1.0 enhancements will also address the integration of a database for Analytical Services Program Integration, budgeting, and scheduling offices into LABCORE

  14. Water reclamation and effluent retreatment system at Jaduguda

    Energy Technology Data Exchange (ETDEWEB)

    Beri, K K [Uranium Corporation of India Limited, Jaduguda Mines, Singhbhum (India)

    1994-06-01

    Neutralization of uranium mill tailing with lime provided in original flow sheet was not found adequate for effluent quality control within limits particularly as regards to{sup 226}Ra and Mn. The same was being controlled by dilution and hence no water was being reclaimed. In October 1987 the Jaduguda mill was expanded to augment its ore processing capacity from 1000 MT/day to 1340 MT/day. This necessitated extra water requirement, which could have been met only with water reclamation. But this would have resulted in build up of pollutant ions apart from less water available for dilution. Hence a composite scheme was made for water reclamation and treatment of effluent with BaCl{sub 2} to precipitate Ba(Ra)So{sub 4} and with lime to precipitate Mn as hydroxide. This effluent treatment plant was commissioned in May 1990 and is working satisfactorily. The scheme is being further modified and augmented to take care of Narwa mine water and sewage treatment plant effluent. (author).

  15. Liquid Effluents Program mission analysis

    International Nuclear Information System (INIS)

    Lowe, S.S.

    1994-01-01

    Systems engineering is being used to identify work to cleanup the Hanford Site. The systems engineering process transforms an identified mission need into a set of performance parameters and a preferred system configuration. Mission analysis is the first step in the process. Mission analysis supports early decision-making by clearly defining the program objectives, and evaluating the feasibility and risks associated with achieving those objectives. The results of the mission analysis provide a consistent basis for subsequent systems engineering work. A mission analysis was performed earlier for the overall Hanford Site. This work was continued by a ''capstone'' team which developed a top-level functional analysis. Continuing in a top-down manner, systems engineering is now being applied at the program and project levels. A mission analysis was conducted for the Liquid Effluents Program. The results are described herein. This report identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and sources of constraints, estimates the resources to carry out the mission, and establishes measures of success. The mission analysis reflects current program planning for the Liquid Effluents Program as described in Liquid Effluents FY 1995 Multi-Year Program Plan

  16. Removal of contaminants in a paper mill effluent by Azolla caroliniana

    Directory of Open Access Journals (Sweden)

    D. Sivakumar

    2015-09-01

    Full Text Available This study was focused on removal of various parameters in paper mill effluent using a method called bioremediation by Azolla caroliniana.  The experimental investigations have been carried out using Azolla caroliniana for conducting the sorption study with various dilution ratios (2, 4, 6, 8, and 10, pH (3, 4, 5, 6, 7, 8 and 9 and biomass (200, 400, 600, 800 and 1000 g. The maximum removal percentage of TDS, BOD and COD in a paper mill effluent was obtained at the optimum dilution ratio of 6, pH of 8 and biomass of 800 g. The results of this study indicated that the maximum removal percentage of TDS, BOD and COD in a paper mill effluent was 82.3 %, 88.6 % and 79.1 % respectively.  Also, the study focused on uptake of TDS, BOD and COD in paper mill effluent by Azolla caroliniana through bioaccumulation factor and translocation factor. The results of bioaccumulation factor revealed that TDS, BOD and COD in paper mill effluent were adsorbed by Azolla caroliniana.  The results of translocation factor revealed that the roots of Azolla caroliniana translocate the TDS, BOD and COD in a paper mill effluent to the shoots of Azolla caroliniana. From the results, this study concluded that bioremediation by Azolla caroliniana could be effectively used for removing TDS, BOD and COD in a paper mill effluent. This study also suggested that Azolla caroliniana may be used for removing various contaminants, not only from paper mill effluent, but also from any other industrial effluents.

  17. The effects of brewery effluent discharge on the water quality and ...

    African Journals Online (AJOL)

    Effluent discharge into the river significantly altered the water quality. Monitoring of effluent discharge into the aquatic environment and strict adherence to regulatory limits will halt further degradation of the environment. Key words: Water, sediment physico-chemistry, distribution coefficient, effluent discharge, tropical river ...

  18. SUSTENTABILIDADE EM SISTEMAS AGROFLORESTAIS: INDICADORES SOCIOECONÔMICOS

    Directory of Open Access Journals (Sweden)

    Omar Daniel

    2000-03-01

    Full Text Available É ampla a discussão que envolve a importância do enquadramento das atividades de produção em geral, ao conceito de desenvolvimento sustentável. Dentre as atividades agropecuárias, os sistemas agroflorestais (SAF têm sido considerados como sustentáveis, apresentando-se como alternativas aos sistemas intensivos de produção. Para monitorar a sustentabilidade de atividades agropecuárias em geral, incluindo os SAF, diferentes autores enfatizam os indicadores biofísicos, em detrimento dos socioeconômicos. Com o objetivo de definir um rol de indicadores socioeconômicos adaptáveis aos diversos modelos de SAF, desenvolveu-se um estudo consolidado por recomendações de especialistas e ampla revisão de literatura. Concluiu-se que: as categorias relacionadas com a operação dos sistemas comportaram o maior número de indicadores no componente socioeconômico, com maior concentração nas operações endógenas ao sistema, seguidas, de longe, pelos recursos endógenos e exógenos; o maior número de indicadores, sugeridos na categoria operação do sistema, deu-se nos descritores saúde e nutrição, empregos, habitação e saneamento básico e análise econômica; na categoria operação de sistemas exógenos, determinou-se maior número de indicadores para os descritores comercialização e infra-estrutura rural; praticamente, não houve diferença entre o número de indicadores obtidos para os sistemas agroflorestais com e sem o componente animal.

  19. Sistemas integrados de gestão empresarial: estudos de casos de implementação de sistemas ERP.

    OpenAIRE

    Cesar Alexandre de Souza

    2000-01-01

    Este trabalho é um estudo das características dos sistemas ERP (Enterprise Resource Planning), de seus processos de escolha, implementação e utilização, de seus benefícios, suas desvantagens e de seus possíveis impactos nas organizações. No levantamento bibliográfico, são apresentados conceitos relacionados aos sistemas ERP, bem como uma proposta de modelo de ciclo para estes sistemas, com a finalidade de estudar suas diferentes etapas na empresa, procurando estabelecer em cada uma delas qua...

  20. Sistemas integrados de gestión (SIG)

    OpenAIRE

    García Pantigozo, Manuel; Quispe Atúncar, Carlos; Ráez Guevara, Luis

    2014-01-01

    La cultura de la normalización es necesaria para competir globalmente, y para esto la ISO ha elaborado una serie de sistemas de gestión orientados a las calidad, medio ambiente, seguridad en el trabajo y recursos humanos, esto significa la necesidad de integrar sistemas mediante el Sistema integrado de Gestión - SIG The culture of standardization is necessary to compete globally, and to this ISO has developed a number of management systems geared to quality, environment, occupational safe...

  1. Importancia del manual de los sistemas contables en el sistema de control interno.

    OpenAIRE

    Nicolás Valdés Rodríguez

    2007-01-01

    La dirección administrativa del país en los últimos 3 años ha insistido en la necesidad de profundizar en los mecanismos de control económico –financiero de las entidades, el presente trabajo va dirigido a contribuir en alguna medida a lograr ese propósito. El sistema contable de una Entidad forma parte indisoluble del Sistema de Control Interno de la misma, por la vinculación tan estrecha que existe entre los mismos. El objetivo fundamental del trabajo ”Importancia del Manual de ...

  2. Phytotoxicity of effluents from swine slaughterhouses using lettuce and cucumber seeds as bioindicators.

    Science.gov (United States)

    Gerber, Michel David; Lucia, Thomaz; Correa, Luciara; Neto, José Eduardo Pereira; Correa, Érico Kunde

    2017-08-15

    This study evaluated the phytotoxic effects of raw and treated effluents from a swine slaughterhouse on cucumber and lettuce seeds and determined correlations among physicochemical characteristics of such effluents and the germination of seeds used as bioindicators. Physicochemical parameters were characterized for both effluents and their phytotoxicity was determined through the germination index (GI), the root length (RL) and the number of germinated seeds (SG) for both plant species. The effluents treatment system was efficient to reduce the concentration of some physicochemical parameters to levels within those recommended by the Brazilian legislation, except for P, ammoniacal N and TKN concentration. Although phytotoxicity of the treated effluent was less in comparison to the raw effluent, the GI for cucumber and lettuce seeds submitted to each of the tested effluents was lower than 80%. Thus, both effluents were phytotoxic for the tested bioindicators (peffluent. The Zn concentration in the treated effluent showed a negative correlation (peffluents from swine slaughterhouses may impair the germination of the evaluated plant species if used for agricultural purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Performance evaluation of effluent treatment plant for automobile industry

    Energy Technology Data Exchange (ETDEWEB)

    Ansari, Farid [Department of Applied Science and Humanities, PDM College of Engineering, Bahadurgarh (Haryana) (India); Pandey, Yashwant K. [School of Energy and Environmental Studies, Devi Ahilya Vishwavidyalaya, Indore (India); Kumar, P.; Pandey, Priyanka [Department of Environmental Science, Post Graduate College Ghazipur (IN

    2013-07-01

    The automobile industry’s wastewater not only contains high levels of suspended and total solids such as oil, grease, dyestuff, chromium, phosphate in washing products, and coloring, at various stages of manufacturing but also, a significant amount of dissolved organics, resulting in high BOD or COD loads. The study reveals the performance, evaluation and operational aspects of effluent treatment plant and its treatability, rather than the contamination status of the real property. The Results revealed that the treated effluent shows most of the parameters are within permissible limits of Central Pollution Control Board (CPCB), India and based on the site visits, discussion with operation peoples, evaluation of process design, treatment system, existing effluent discharge, results of sample analyzed and found that effluent treatment plant of automobile industry are under performance satisfactory.

  4. Control of effluents and environmental surveillance of the CEA centres. 1997 status; Controle des rejets et surveillance de l'environnement des centres CEA. Bilan 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    The environmental quality in the vicinity of CEA facilities is a major concern of the safety policy of the CEA. The aim of this document is to inform the public about the gaseous and liquids radioactive effluents released by the CEA centres under the permission of the ministry. It provides a status of the effluents and of the radioactivity levels measured near the CEA centres in 1997, using air, water, vegetation and milk samples. A comparison is made with the measurements performed during the 1993-1996 period. The data presented comes from the regulatory registers transmitted to the agency for the protection against ionizing radiations (OPRI) which belongs to the ministry of health. (J.S.)

  5. Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities

    International Nuclear Information System (INIS)

    Ballinger, M.Y.; Shields, K.D.

    1999-01-01

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) facilities. Activities in the BOP facilities range from administrative to laboratory and pilot-scale R and D. R and D activities include both radioactive and chemical waste characterization, fluid dynamics research, mechanical property testing, dosimetry research, and molecular sciences. The mission and activities for individual buildings are described in the FEMP

  6. Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Ballinger, M.Y.; Shields, K.D.

    1999-04-02

    The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) facilities. Activities in the BOP facilities range from administrative to laboratory and pilot-scale R and D. R and D activities include both radioactive and chemical waste characterization, fluid dynamics research, mechanical property testing, dosimetry research, and molecular sciences. The mission and activities for individual buildings are described in the FEMP.

  7. Degradation of 2,4,6-Trinitrophenol (TNP) by Arthrobacter sp. HPC1223 Isolated from Effluent Treatment Plant

    OpenAIRE

    Qureshi, Asifa; Kapley, Atya; Purohit, Hemant J.

    2012-01-01

    Arthrobacter sp. HPC1223 (Genebank Accession No. AY948280) isolated from activated biomass of effluent treatment plant was capable of utilizing 2,4,6 trinitrophenol (TNP) under aerobic condition at 30 °C and pH 7 as nitrogen source. It was observed that the isolated bacteria utilized TNP up to 70 % (1 mM) in R2A media with nitrite release. The culture growth media changed into orange-red color hydride-meisenheimer complex at 24 h as detected by HPLC. Oxygen uptake of Arthrobacter HPC1223 towa...

  8. Recycling liquid effluents in a ceramic industry

    International Nuclear Information System (INIS)

    Araujo Almeida, B.; Almeida, M.; Martins, S.; Alexandra Macarico, V.; Tomas da Fonseca, A.

    2016-01-01

    In this work is presented a study on the recycling of liquid effluents in a ceramic installation for sanitary industry. The effluents were characterized by X-ray diffraction and inductively coupled plasma to evaluate their compositions. It was also assessed the daily production rate. Several glaze-slurry mixtures were prepared and characterized according to procedures and equipment of the company's quality laboratory. The results show that for most of the properties, the tested mixtures exhibited acceptable performance. However, the pyro plasticity parameter is highly influenced by the glaze content and imposes the separation of glaze and slurry liquid effluents. In addition, it is necessary to invest on a storage plant, including tanks with constant stirring and a new pipeline structure to implement the reincorporation method on the slurry processing. (Author)

  9. Effluent treatment options for nuclear thermal propulsion system ground tests

    International Nuclear Information System (INIS)

    Shipers, L.R.; Brockmann, J.E.

    1992-01-01

    A variety of approaches for handling effluent from nuclear thermal propulsion system ground tests in an environmentally acceptable manner are discussed. The functional requirements of effluent treatment are defined and concept options are presented within the framework of these requirements. System concepts differ primarily in the choice of fission-product retention and waste handling concepts. The concept options considered range from closed cycle (venting the exhaust to a closed volume or recirculating the hydrogen in a closed loop) to open cycle (real time processing and venting of the effluent). This paper reviews the strengths and weaknesses of different methods to handle effluent from nuclear thermal propulsion system ground tests

  10. PRESENTACIÓN DE LA CARRERA DE INGENIERÍA DE SISTEMAS

    Directory of Open Access Journals (Sweden)

    EDGAR SERNA MONTOYA

    2009-06-01

    Full Text Available En el año 2009 la Facultad cuenta con los siguientes programas activos:* Pregrado en Ingeniería de Sistemas Presencial Registro Calificado Código SNIES 11846 Resolución No. 2293 del 03 de octubre de 2002. Título que otorga: Doble titulación, Ingeniero de Sistemas y Tecnólogo en Sistemas.* Ciclo de Profesionalización para Tecnólogos en Sistemas Presencial Título que otorga: Ingeniero de Sistemas.* Tecnología en Sistemas de Información Presencial Registro Calificado Código SNIES 11850 Título que otorga: Tecnólogo en Sistemas de Información.* Especialización en Gerencia de la Tecnología Presencial Registro Calificado Código SNIES 53168 Título que otorga: Especialista en gerencia de la Tecnología.

  11. Impact of fertilizer plant effluent on water quality

    International Nuclear Information System (INIS)

    Obire, O.; Ogan, A.; Okigbo, R. N.

    2008-01-01

    The impact of National Fertilizer Company of Nigeria out fall effluent on the physico chemistry and bacteriology of Okrika creek was investigated during the sampling period from May to December, 1998. The National Fertilizer Company of Nigeria out fall effluent, the Okrika creek water and the lkpukulubie creek (control) water samples were collected. The physico-chemical parameters analyzed for all the samples included temperature, p H, total chloride, total dissolved solids, dissolved oxygen, conductivity, free ammonia, total phosphate, urea, zinc and iron, while the bacteriological determinations were total culturable aerobic heterotrophic bacteria count and identification of representative isolates. The Okrika creek recorded higher concentrations for all the physicochemical parameters and bacteria load than the control creek. The higher values of p H, Free NH 3 , urea, TDS and the conductivity of the National Fertilizer Company of Nigeria out fall effluent above the FEPA standards reflect the poor effluent quality generated by National Fertilizer Company of Nigeria. The bacteria species isolated from the samples include Aerococcus viridans, Alcaligenes faecalis, Bacillus cereus, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, Proteus vulgaris, Pseudomonas aeruginosa, Serratia marcescens and Staphylococcus aureus. In general, the investigation revealed that there was an extremely adverse impact on the physico-chemical and bacteriological water quality characteristics of the Okrika creek as a result of the discharge of poor quality effluent from National Fertilizer Company of Nigeria operations

  12. Atmospheric Dispersion Assessment for Potential Accidental Releases at Yonggwang Nuclear Power Plants

    International Nuclear Information System (INIS)

    Na, Man Gyun; Sim, Young Rok; Jung, Chul Kee; Lee, Goung Jin; Kim, Soong Pyung; Chung, Sung Tai

    2000-01-01

    XOQ DW code is currently used to assess the atmospheric dispersion for the routine releases of radioactive gaseous effluents at Yonggwang nuclear power plants. This code was developed based on XOQDOQ code and an additional code is required to assess the atmospheric dispersion for potential accidental releases. In order to assess the atmospheric dispersion for the accidental releases, XOQAR code has been developed by using PAVAN code that is based on Reg. Guide 1.145. The terrain data of XOQ DW code inputs and the relative concentrations (X/Q) of XOQ DW code outputs are used as the inputs of the XOQAR code through the interface with XOQ DW code. By using this code, the maximum values of X/Q at exclusion area and low population zone boundaries except for sea areas were assessed as 1.33 x 10 -4 and 7.66 x 10 -6 sec/m 3 , respectively. Through the development of this code, a code system is prepared for assessing the atmospheric dispersion for the accidental releases as well as the routine releases. This developed code can be used for other domestic nuclear power plants by modifying the terrain input data

  13. Facility Effluent Monitoring Plan for the Plutonium Finishing Plant (PFP); FINAL

    International Nuclear Information System (INIS)

    FRAZIER, T.P.

    1999-01-01

    A facility effluent monitoring plan is required by the U. S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could impact employee or public safety or the environment. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether these systems are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. To ensure the long-range integrity of the effluent monitoring systems, an update to this facility effluent monitoring plan is required whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document is reviewed annually even if there are no operational changes, and is updated, at a minimum, every 3 years

  14. Sistema de blocos prensados e doses de adubo de liberação lenta na formação de porta-enxerto cítrico Pressed blocks system and slow release fertilizer levels for citrus rootstock formation

    Directory of Open Access Journals (Sweden)

    Luiz Augusto Lopes Serrano

    2006-04-01

    Full Text Available Devido à restrição que os tubetes impõem ao crescimento lateral do sistema radicular, o uso de materiais orgânicos prensados está sendo utilizado para a produção de mudas de espécies florestais. O objetivo do trabalho foi avaliar a produção do porta-enxerto cítrico limoeiro 'Cravo' no sistema de blocos prensados até a repicagem, e o efeito deste sistema e de doses de um fertilizante de liberação lenta sobre o crescimento desse porta-enxerto até o ponto de enxertia. Avaliaram-se três sistemas de produção até a repicagem: em tubetes preenchidos com substrato comercial composto por casca de pínus; em tubetes preenchidos com substrato composto pela mistura entre bagaço de cana e torta de filtro (3:2; v:v; e em "blocos prensados" constituídos pela prensagem do substrato composto pela mistura entre bagaço de cana e torta de filtro (3:2; v:v. Da repicagem à enxertia, foram empregadas cinco doses de Osmocote® (NPK 14-14-14: 5, 10, 15, 20 e 25g planta-1. As mudas provenientes do sistema de blocos prensados atingiram o ponto de repicagem e o de enxertia mais rapidamente que as produzidas em tubetes. No ponto de enxertia, estas apresentaram maiores médias de diâmetro de caule e massa seca da parte aérea e do sistema radicular. O sistema utilizado na produção do porta-enxerto também interferiu na resposta das mudas à adubação empregada.Due to the restriction that the stiff plastic tubes impose to the lateral growth of the root system, the use of pressed organic materials has been proposed for the production of forests species seedlings. The research was carried out with the objectives of evaluating the production of rootstock 'Rangpur' lime tree in pressed blocks until the transplant, and the effect of those systems were evaluated and doses of slow release fertilizer on the growth of that rootstock until the grafting point. Three production systems were evaluated: in stiff plastic tubes filled up with commercial substrate

  15. Construindo um modelo de sistema de cuidados Construyendo un modelo de sistema de cuidados Developing an explanatory theoretical model of system of care

    Directory of Open Access Journals (Sweden)

    Alacoque Lorenzini Erdmann

    2007-06-01

    Full Text Available OBJETIVO: Construir um modelo teórico explicativo de Sistema de Cuidados. METODO: Estudo exploratório qualitativo apoiado nos pressupostos da Grounded Theory. Participaram do estudo 15 profissionais e os dados foram coletados por entrevista aberta. RESULTADOS: O Modelo teórico foi delimitado a partir do fenômeno Construindo o Sistema Complexo de Cuidados determinado pelas categorias: Convivendo com a dinamicidade do sistema de cuidados e Organizando o sistema de cuidados a partir de múltiplas interações. CONCLUSÃO: O modelo de sistema de cuidados apresentou-se como sistema vital e dinâmico construído a partir de redes interacionais de vários saberes do agir humano expresso pelo trabalho compartilhado, multidisciplinar e em equipe.OBJETIVO: Construir un modelo teórico explicativo de Sistema de Cuidados. MÉTODO: Se trata de un estudio cualitativo exploratorio apoyado en las premisas de la Teoría Fundamentada en los Datos. Participaron del estudio 15 profesionales. Los datos fueron recolectados por medio de una entrevista abierta. RESULTADOS: El modelo teórico se delimitó al fenómeno Construyendo el Sistema Complejo de Cuidados determinado por las categorías: Viviendo junto con la dinamicidad del sistema de cuidados y Organizando el sistema de cuidados a partir de interacciones múltiples. CONCLUSIÓN: El modelo de sistema de cuidados se presenta como un sistema vital y dinámico construido a partir de redes de interacción de conocimientos del actuar humano expresado en el trabajo conjunto, multidisciplinario y en equipo.OBJECTIVE: To develop an explanatory theoretical model of the system of care. METHOD: Grounded theory served as the conceptual framework to conduct this qualitative exploratory study. Unstructured interviews were conducted among 15 care professionals. RESULTS: The theoretical model was delimited from the phenomenon "building complex system of care" as determined by the following categories: "dealing with a

  16. Prevalence of Listeria monocytogenes in the river receiving the effluent of municipal wastewater treatment plant

    Directory of Open Access Journals (Sweden)

    Atefeh Taherkhani

    2013-01-01

    Full Text Available Aims: The objective of this study was to evaluate the prevalence of Listeria spp. in the river water before and after discharge of the effluent of the municipal wastewater treatment plant (WWTP in Isfahan, Iran. Materials and Methods: A total of 66 samples were collected bi-weekly over 4 months from eleven discrete sampling locations in Zayandehrood River, Iran. Three sampling sites were located above the discharge point and five sites were located after the discharge point of WWTP. Samples were also collected from the influent and the effluent of WWTP. Listeria spp. were isolated using a selective enrichment procedure and a subculture onto polymyxin-acriflavine-lithium chloride-ceftazidime-esculin-mannitol Agar. All isolates were subjected to standard biochemical tests. Results: L. monocytogenes was isolated from influent (83%, effluent (50% and (18.5% river water. Listeria spp. was not found before the discharge point in river water. However, L. monocytogenes was isolated in samples collected from 200 m (33%, 500 m (33%, 2 km (16.5%, 5 km (16.5% and 10 km (16.5% downstream from the WWTP. Listeria innocua (9% and Listeria seeligeri (10% were the second most frequently isolated species. Conclusion: During the wastewater treatment, Listeria spp. is not removed completely. L. monocytogenes is widely distributed in the Zayandehrood river. L. monocytogenes released into surface water demonstrates a potential risk for public health. These results indicate the need for appropriate water management in order to reduce human and animal exposure to such pathogens.

  17. Characteristics of treated effluents and their potential applications for producing concrete.

    Science.gov (United States)

    Noruzman, Ainul Haezah; Muhammad, Bala; Ismail, Mohammad; Abdul-Majid, Zaiton

    2012-11-15

    Conservation and preservation of freshwater is increasingly becoming important as the global population grows. Presently, enormous volumes of freshwater are used to mix concrete. This paper reports experimental findings regarding the feasibility of using treated effluents as alternatives to freshwater in mixing concrete. Samples were obtained from three effluent sources: heavy industry, a palm-oil mill and domestic sewage. The effluents were discharge into public drain without danger to human health and natural environment. Chemical compositions and physical properties of the treated effluents were investigated. Fifteen compositional properties of each effluent were correlated with the requirements set out by the relevant standards. Concrete mixes were prepared using the effluents and freshwater to establish a base for control performance. The concrete samples were evaluated with regard to setting time, workability, compressive strength and permeability. The results show that except for some slight excesses in total solids and pH, the properties of the effluents satisfy the recommended disposal requirements. Two concrete samples performed well for all of the properties investigated. In fact, one sample was comparatively better in compressive strength than the normal concrete; a 9.4% increase was observed at the end of the curing period. Indeed, in addition to environmental conservation, the use of treated effluents as alternatives to freshwater for mixing concrete could save a large amount of freshwater, especially in arid zones. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Irrigation Suitability Assessment of Effluents From West Kano Rice ...

    African Journals Online (AJOL)

    Choice-Academy

    lake water, and an excess in effluents. The excess nitrates in effluents pollute the lake, but could help as crop .... modelling assessment method proposed in this study can be used to ... economic and environmental impact assessment research ...

  19. Cultivo hidropônico de tomate cereja utilizando-se efluente tratado de uma indústria de sorvete Hydroponic production of cherry tomatoes using treated effluent of ice cream industry

    Directory of Open Access Journals (Sweden)

    Samuel M. M. Malheiros

    2012-10-01

    Full Text Available O objetivo deste trabalho foi avaliar o uso de doses de efluente oriundo de indústria de sorvete, na cultura do tomate cereja em relação ao consumo hídrico e no desenvolvimento vegetativo em sistema hidropônico. O delineamento experimental foi o inteiramente casualizado, com seis tratamentos e quatro repetições. Os tratamentos foram compostos pelo uso de doses de efluente (0, 25, 50, 75 e 100% com complementação de nutrientes e com o uso de 100% de efluente sem complementação nutriente. O aumento das doses de efluente na solução nutritiva proporcionou redução linear no consumo hídrico. O efluente com 25% proporcionou a melhor produtividade. A adição de até 50% de efluente de sorvete à solução nutritiva permitiu o cultivo de tomate cereja sem redução na produtividade, com melhor eficiência do uso da água na produção de matéria seca da parte aérea, produção de frutos e máxima substituição de minerais solúveis na solução nutritiva.The objective of this study was to evaluate the effect of ice cream raw effluent doses on consumption and vegetative development of cherry tomato under hydroponic system. The experiment was conducted in completely randomized design with six treatments and four replications. Treatments consisted of 5 different levels of effluent (0, 25, 50, 75 and 100% complemented with the amount of nutrient recommended for growing tomatoes and 100% of effluent without nutrient complementation. Increasing doses of effluent provided linear reduction in water consumption.Addition of effluent in proportion of 25% provided best production results. Addition up to 50% ice cream effluent to nutrient solution allowed growth of cherry tomato without yield reduction providing better efficiency of water use in terms of dry weight of shoots and fruit production as well as maximum substitution of soluble mineral fertilizers in nutrient solution.

  20. Toxicity of effluents from gasoline stations oil-water separators to early life stages of zebrafish Danio rerio.

    Science.gov (United States)

    Alves, Romulo Nepomuceno; Mariz, Célio Freire; Paulo, Driele Ventura de; Carvalho, Paulo S M

    2017-07-01

    Used petroleum hydrocarbons and gasoline stations runoff are significant sources of polycyclic aromatic hydrocarbons (PAHs) to aquatic ecosystems. Samples of the final effluent of oil-water-separators were collected at gasoline stations in the metropolitan region of Recife, Brazil, before release to sewage or rainwater systems. Effluent soluble fractions (ESF) were prepared and bioassays were performed according to the Fish Embryo Toxicity Test. The test involved exposing zebrafish Danio rerio embryos to dilutions of the ESFs for 96 h, with daily examination of lethality and sublethal morphological effects integrated through the General Morphology Score (GMS), based on the achievement of developmental hallmarks. Frequencies of abnormalities were recorded after exposures. ESF LC50-96h (lethal concentration to 50% of exposed embryos) in the most toxic effluent achieved 8.9% (v/v), equivalent to 11 μg phenanthrene equivalents L -1 . GMS scores indicated significantly delayed embryo-larval development at ESF dilutions of 10% and 20% from effluents of all gas stations. Major abnormalities detected after the 96 h exposure included the presence of a yolk sac not fully absorbed coupled with the lack of an inflated swim bladder, lack of both pectoral fins, and the failure to develop a protruding mouth. Effective equivalent PAH concentrations that induce a 50% frequency of larvae without an inflated swim bladder (EC50) were 4.9 μg phenanthrene L -1 , 21.8 μg naphthalene L -1 , and 34.1 μg chrysene L -1 . This study shows that PAHs in ESFs from gas stations oil water separators are toxic to zebrafish, contributing to the toxicity of urban storm waters. Copyright © 2017 Elsevier Ltd. All rights reserved.