Sample records for efficient gamma index

  1. Efficient gamma index calculation using fast Euclidean distance transform

    Energy Technology Data Exchange (ETDEWEB)

    Chen Mingli; Lu Weiguo; Chen Quan; Ruchala, Kenneth; Olivera, Gustavo [TomoTherapy Inc., 1240 Deming Way, Madison, WI 53717 (United States)], E-mail: wlu@tomotherapy.com

    2009-04-07

    The gamma index is a tool for dose distribution comparison. It combines both dose difference (DD) and distance to agreement (DTA) into a single quantity. Though it is an effective measure, making up for the inadequacy of DD or DTA alone, its calculation can be very time-consuming. For a k-D space with N quantization levels in each dimension, the complexity of the exhaustive search is O(N{sup 2k}). In this work, we proposed an efficient method that reduces the complexity from O(N{sup 2k}) to O(N{sup k}M), where M is the number of discretized dose values and is comparable to N. More precisely, by embedding the reference dose distribution in a (k+1)-D spatial-dose space, we can use fast Euclidean distance transform with linear complexity to obtain a table of gamma indices evaluated over a range of the (k+1)-D spatial-dose space. Then, to obtain gamma indices for the test dose distribution, it requires only table lookup with complexity O(N{sup k}). Such a table can also be used for other test dose distributions as long as the reference dose distribution is the same. Simulations demonstrated the efficiency of our proposed method. The speedup for 3D gamma index calculation is expected to be on the order of tens of thousands (from O(N{sup 6}) to O(N{sup 3}M)) if N is a few hundreds, which makes clinical usage of the 3D gamma index feasible. A byproduct of the gamma index table is that the gradient of the gamma index with respect to either the spatial or dose dimension can be easily derived. The gradient can be used to identify the main causes of the discrepancy from the reference distribution at any dose point in the test distribution or incorporated in treatment planning and machine parameter optimization.

  2. Impact of image noise on gamma index calculation

    International Nuclear Information System (INIS)

    Chen, M; Mo, X; Parnell, D; Olivera, G; Galmarini, D; Lu, W

    2014-01-01

    Purpose: The Gamma Index defines an asymmetric metric between the evaluated image and the reference image. It provides a quantitative comparison that can be used to indicate sample-wised pass/fail on the agreement of the two images. The Gamma passing/failing rate has become an important clinical evaluation tool. However, the presence of noise in the evaluated and/or reference images may change the Gamma Index, hence the passing/failing rate, and further, clinical decisions. In this work, we systematically studied the impact of the image noise on the Gamma Index calculation. Methods: We used both analytic formulation and numerical calculations in our study. The numerical calculations included simulations and clinical images. Three different noise scenarios were studied in simulations: noise in reference images only, in evaluated images only, and in both. Both white and spatially correlated noises of various magnitudes were simulated. For clinical images of various noise levels, the Gamma Index of measurement against calculation, calculation against measurement, and measurement against measurement, were evaluated. Results: Numerical calculations for both the simulation and clinical data agreed with the analytic formulations, and the clinical data agreed with the simulations. For the Gamma Index of measurement against calculation, its distribution has an increased mean and an increased standard deviation as the noise increases. On the contrary, for the Gamma index of calculation against measurement, its distribution has a decreased mean and stabilized standard deviation as the noise increases. White noise has greater impact on the Gamma Index than spatially correlated noise. Conclusions: The noise has significant impact on the Gamma Index calculation and the impact is asymmetric. The Gamma Index should be reported along with the noise levels in both reference and evaluated images. Reporting of the Gamma Index with switched roles of the images as reference and

  3. Impact of Image Noise on Gamma Index Calculation

    Science.gov (United States)

    Chen, M.; Mo, X.; Parnell, D.; Olivera, G.; Galmarini, D.; Lu, W.

    2014-03-01

    Purpose: The Gamma Index defines an asymmetric metric between the evaluated image and the reference image. It provides a quantitative comparison that can be used to indicate sample-wised pass/fail on the agreement of the two images. The Gamma passing/failing rate has become an important clinical evaluation tool. However, the presence of noise in the evaluated and/or reference images may change the Gamma Index, hence the passing/failing rate, and further, clinical decisions. In this work, we systematically studied the impact of the image noise on the Gamma Index calculation. Methods: We used both analytic formulation and numerical calculations in our study. The numerical calculations included simulations and clinical images. Three different noise scenarios were studied in simulations: noise in reference images only, in evaluated images only, and in both. Both white and spatially correlated noises of various magnitudes were simulated. For clinical images of various noise levels, the Gamma Index of measurement against calculation, calculation against measurement, and measurement against measurement, were evaluated. Results: Numerical calculations for both the simulation and clinical data agreed with the analytic formulations, and the clinical data agreed with the simulations. For the Gamma Index of measurement against calculation, its distribution has an increased mean and an increased standard deviation as the noise increases. On the contrary, for the Gamma index of calculation against measurement, its distribution has a decreased mean and stabilized standard deviation as the noise increases. White noise has greater impact on the Gamma Index than spatially correlated noise. Conclusions: The noise has significant impact on the Gamma Index calculation and the impact is asymmetric. The Gamma Index should be reported along with the noise levels in both reference and evaluated images. Reporting of the Gamma Index with switched roles of the images as reference and

  4. Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Sumida, Iori, E-mail: sumida@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Yamaguchi, Hajime; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yoshikawa, Nobuhiko; Yamada, Yuji [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Suzuki, Osamu; Seo, Yuji [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Isohashi, Fumiaki [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Yoshioka, Yasuo [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Ogawa, Kazuhiko [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan)

    2015-07-15

    Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV, spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.

  5. Probing a Possible Vacuum Refractive Index with Gamma-Ray Telescopes

    CERN Document Server

    Ellis, John; Nanopoulos, D V; PH-TH

    2009-01-01

    We have used a stringy model of quantum space-time foam to suggest that the vacuum may exhibit a non-trivial refractive index depending linearly on gamma-ray energy: eta -1 ~ E_gamma/M_QG1, where M_QG1 is some mass scale typical of quantum gravity that may be ~ 10^18 GeV: see Phys. Lett. B 665, 412 (2008) and references therein. The MAGIC, HESS and Fermi gamma-ray telescopes have recently probed the possible existence of such an energy-dependent vacuum refractive index. All find indications of time-lags for higher-energy photons, but cannot exclude the possibility that they are due to intrinsic delays at the sources. However, the MAGIC and HESS observations of time-lags in emissions from AGNs Mkn 501 and PKS 2155-304 are compatible with each other and a refractive index depending linearly on the gamma-ray energy, with M_QG1 ~ 10^18 GeV. We combine their results to estimate the time-lag Delta t to be expected for the highest-energy photon from GRB 080916c measured by the Fermi telescope, which has an energy ~ ...

  6. THE BRAKING INDEX OF A RADIO-QUIET GAMMA-RAY PULSAR

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. J.; Pletsch, H. J.; Allen, B.; Aulbert, C.; Beer, C.; Bock, O.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Machenschalk, B.; Nieder, L. [Albert-Einstein-Institut, Max-Planck-Institut für Gravitationsphysik, D-30167 Hannover (Germany); Wu, J.; Guillemot, L.; Kramer, M. [Max-Planck-Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany); Camilo, F. [SKA South Africa, Pinelands, 7405 (South Africa); Johnson, T. J. [College of Science, George Mason University, Fairfax, VA 22030 (United States); Kerr, M., E-mail: colin.clark@aei.mpg.de [CSIRO Astronomy and Space Science, Australia Telescope National Facility, Epping, NSW 1710 (Australia)

    2016-11-20

    We report the discovery and timing measurements of PSR J1208−6238, a young and highly magnetized gamma-ray pulsar, with a spin period of 440 ms. The pulsar was discovered in gamma-ray photon data from the Fermi Large Area Telescope (LAT) during a blind-search survey of unidentified LAT sources, running on the distributed volunteer computing system Einstein@Home . No radio pulsations were detected in dedicated follow-up searches with the Parkes radio telescope, with a flux density upper limit at 1369 MHz of 30 μ Jy. By timing this pulsar’s gamma-ray pulsations, we measure its braking index over five years of LAT observations to be n = 2.598 ± 0.001 ± 0.1, where the first uncertainty is statistical and the second estimates the bias due to timing noise. Assuming its braking index has been similar since birth, the pulsar has an estimated age of around 2700 years, making it the youngest pulsar to be found in a blind search of gamma-ray data and the youngest known radio-quiet gamma-ray pulsar. Despite its young age, the pulsar is not associated with any known supernova remnant or pulsar wind nebula. The pulsar’s inferred dipolar surface magnetic field strength is 3.8 × 10{sup 13} G, almost 90% of the quantum-critical level. We investigate some potential physical causes of the braking index deviating from the simple dipole model but find that LAT data covering a longer time interval will be necessary to distinguish between these.

  7. THE BRAKING INDEX OF A RADIO-QUIET GAMMA-RAY PULSAR

    International Nuclear Information System (INIS)

    Clark, C. J.; Pletsch, H. J.; Allen, B.; Aulbert, C.; Beer, C.; Bock, O.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Machenschalk, B.; Nieder, L.; Wu, J.; Guillemot, L.; Kramer, M.; Camilo, F.; Johnson, T. J.; Kerr, M.

    2016-01-01

    We report the discovery and timing measurements of PSR J1208−6238, a young and highly magnetized gamma-ray pulsar, with a spin period of 440 ms. The pulsar was discovered in gamma-ray photon data from the Fermi Large Area Telescope (LAT) during a blind-search survey of unidentified LAT sources, running on the distributed volunteer computing system Einstein@Home . No radio pulsations were detected in dedicated follow-up searches with the Parkes radio telescope, with a flux density upper limit at 1369 MHz of 30 μ Jy. By timing this pulsar’s gamma-ray pulsations, we measure its braking index over five years of LAT observations to be n = 2.598 ± 0.001 ± 0.1, where the first uncertainty is statistical and the second estimates the bias due to timing noise. Assuming its braking index has been similar since birth, the pulsar has an estimated age of around 2700 years, making it the youngest pulsar to be found in a blind search of gamma-ray data and the youngest known radio-quiet gamma-ray pulsar. Despite its young age, the pulsar is not associated with any known supernova remnant or pulsar wind nebula. The pulsar’s inferred dipolar surface magnetic field strength is 3.8 × 10 13 G, almost 90% of the quantum-critical level. We investigate some potential physical causes of the braking index deviating from the simple dipole model but find that LAT data covering a longer time interval will be necessary to distinguish between these.

  8. Malmquist Productivity Index on Efficiency Layers

    Directory of Open Access Journals (Sweden)

    F. Rezai balf ∗

    2012-09-01

    Full Text Available Data Envelopment Analysis (DEA, a popular linear programming technique is useful to rate comparatively operational effiency of decision Making Unit (DMU based on the their deterministic inputoutput data. The Malmquist productivity index in DEA, calculable with the distance function, for measurement the productivity change among two variant time period or two variant group in the same time. This index is based on two factor of efficiency change index and a technological change index. In this paper, we operate on the collective Malmquist productivity index, which performs clustering operation DMUs with classification into different levels of efficient frontier, and then we discuss on the relation between Malmquist index on the efficiency layers and their attractiveness and progress

  9. Derivative based sensitivity analysis of gamma index

    Directory of Open Access Journals (Sweden)

    Biplab Sarkar

    2015-01-01

    Full Text Available Originally developed as a tool for patient-specific quality assurance in advanced treatment delivery methods to compare between measured and calculated dose distributions, the gamma index (γ concept was later extended to compare between any two dose distributions. It takes into effect both the dose difference (DD and distance-to-agreement (DTA measurements in the comparison. Its strength lies in its capability to give a quantitative value for the analysis, unlike other methods. For every point on the reference curve, if there is at least one point in the evaluated curve that satisfies the pass criteria (e.g., δDD = 1%, δDTA = 1 mm, the point is included in the quantitative score as "pass." Gamma analysis does not account for the gradient of the evaluated curve - it looks at only the minimum gamma value, and if it is <1, then the point passes, no matter what the gradient of evaluated curve is. In this work, an attempt has been made to present a derivative-based method for the identification of dose gradient. A mathematically derived reference profile (RP representing the penumbral region of 6 MV 10 cm × 10 cm field was generated from an error function. A general test profile (GTP was created from this RP by introducing 1 mm distance error and 1% dose error at each point. This was considered as the first of the two evaluated curves. By its nature, this curve is a smooth curve and would satisfy the pass criteria for all points in it. The second evaluated profile was generated as a sawtooth test profile (STTP which again would satisfy the pass criteria for every point on the RP. However, being a sawtooth curve, it is not a smooth one and would be obviously poor when compared with the smooth profile. Considering the smooth GTP as an acceptable profile when it passed the gamma pass criteria (1% DD and 1 mm DTA against the RP, the first and second order derivatives of the DDs (δD', δD" between these two curves were derived and used as the

  10. Mutagenic effectiveness and efficiency of EMS, DES and gamma-rays in rice

    International Nuclear Information System (INIS)

    Kaul, M.L.H.; Bhan, A.K.

    1977-01-01

    Data on chlorophyll mutation frequency after treatment with EMS, DES and gamma-rays and sequential administration of gamma-rays and the two alkylating agents in three varieties of rice have been used to work out quantitatively the effectiveness and efficiency of each mutagen and combination treatment. For effectiveness, the order is EMS > DES and for efficiency it is EMS > DES > gamma-rays. In some sequential treatments (Gamma-rays + DES in 'IR8' and 'Basmati'; DES + gamma-rays in 'IR8' and 'Jhona'; Gamma-rays + EMS in 'IR8' and 'Basmati'; and EMS + gamma-rays in 'IR8', 'Jhona' and 'Basmati') mutation frequency is more than additive (synergistic) but these treatments are decisively less efficient because of their relatively high injurious effects in the M 1 generation. EMS induces more albinas than gamma-rays do. The mutational spectrum patterns induced by gamma-rays and DES are alike. In general, combination treatments tend to increase the frequency of albinas over other types of chlorophyll mutants. (orig.) [de

  11. SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, N [University of Miami, Miami, FL (United States); Denissova, S [Sylvester Comprehensive Cancer Center Deerfield, Weston, FL (United States)

    2016-06-15

    Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% to 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.

  12. Absolute peak detection efficiencies of a Ge(Li) detector for high gamma-ray energies

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1985-11-01

    Absolute peak detection efficiencies of a Ge(Li) detector for gamma-rays of 3.5 MeV to 12 MeV were measured using four (p,γ) reactions and a (n,γ) reaction. Two-line-method was used to obtaine peak detection efficiencies. The efficiencies with the both cases are agreed very well. Utilization of (n,γ) reaction is, therefore, effective for measuring these efficiencies, because high energy gamma-rays can be generated easily by using a neutron source. These results were applied to calibration of a gamma-ray standard source, emitting 6.13 MeV gamma-rays, and of intensities of 56 Co standard gamma-ray source. (author)

  13. Efficiency curves of NIRR-1 gamma-ray spectrometry system at near ...

    African Journals Online (AJOL)

    The full-energy peak efficiency curves of the gamma-ray spectrometry for use with the Nigeria Research Reactor-1 (NIRR-1) have been determined by both theoretical and experimental at two source-detector positions for routine neutron activation analysis. Standard gamma ray sources were used to determine the efficiency ...

  14. Interpretation of Gamma Index for Quality Assurance of Simultaneously Integrated Boost (SIB) IMRT Plans for Head and Neck Carcinoma

    Science.gov (United States)

    Atiq, Maria; Atiq, Atia; Iqbal, Khalid; Shamsi, Quratul ain; Andleeb, Farah; Buzdar, Saeed Ahmad

    2017-12-01

    Objective: The Gamma Index is prerequisite to estimate point-by-point difference between measured and calculated dose distribution in terms of both Distance to Agreement (DTA) and Dose Difference (DD). This study aims to inquire what percentage of pixels passing a certain criteria assure a good quality plan and suggest gamma index as efficient mechanism for dose verification of Simultaneous Integrated Boost Intensity Modulated Radiotherapy plans. Method: In this study, dose was calculated for 14 head and neck patients and IMRT Quality Assurance was performed with portal dosimetry using the Eclipse treatment planning system. Eclipse software has a Gamma analysis function to compare measured and calculated dose distribution. Plans of this study were deemed acceptable when passing rate was 95% using tolerance for Distance to agreement (DTA) as 3mm and Dose Difference (DD) as 5%. Result and Conclusion: Thirteen cases pass tolerance criteria of 95% set by our institution. Confidence Limit for DD is 9.3% and for gamma criteria our local CL came out to be 2.0% (i.e., 98.0% passing). Lack of correlation was found between DD and γ passing rate with R2 of 0.0509. Our findings underline the importance of gamma analysis method to predict the quality of dose calculation. Passing rate of 95% is achieved in 93% of cases which is adequate level of accuracy for analyzed plans thus assuring the robustness of SIB IMRT treatment technique. This study can be extended to investigate gamma criteria of 5%/3mm for different tumor localities and to explore confidence limit on target volumes of small extent and simple geometry.

  15. Application of the EXtrapolated Efficiency Method (EXEM) to infer the gamma-cascade detection efficiency in the actinide region

    Energy Technology Data Exchange (ETDEWEB)

    Ducasse, Q. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); CEA-Cadarache, DEN/DER/SPRC/LEPh, 13108 Saint Paul lez Durance (France); Jurado, B., E-mail: jurado@cenbg.in2p3.fr [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Mathieu, L.; Marini, P. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Morillon, B. [CEA DAM DIF, 91297 Arpajon (France); Aiche, M.; Tsekhanovich, I. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France)

    2016-08-01

    The study of transfer-induced gamma-decay probabilities is very useful for understanding the surrogate-reaction method and, more generally, for constraining statistical-model calculations. One of the main difficulties in the measurement of gamma-decay probabilities is the determination of the gamma-cascade detection efficiency. In Boutoux et al. (2013) [10] we developed the EXtrapolated Efficiency Method (EXEM), a new method to measure this quantity. In this work, we have applied, for the first time, the EXEM to infer the gamma-cascade detection efficiency in the actinide region. In particular, we have considered the {sup 238}U(d,p){sup 239}U and {sup 238}U({sup 3}He,d){sup 239}Np reactions. We have performed Hauser–Feshbach calculations to interpret our results and to verify the hypothesis on which the EXEM is based. The determination of fission and gamma-decay probabilities of {sup 239}Np below the neutron separation energy allowed us to validate the EXEM.

  16. Application of the EXtrapolated Efficiency Method (EXEM) to infer the gamma-cascade detection efficiency in the actinide region

    International Nuclear Information System (INIS)

    Ducasse, Q.; Jurado, B.; Mathieu, L.; Marini, P.; Morillon, B.; Aiche, M.; Tsekhanovich, I.

    2016-01-01

    The study of transfer-induced gamma-decay probabilities is very useful for understanding the surrogate-reaction method and, more generally, for constraining statistical-model calculations. One of the main difficulties in the measurement of gamma-decay probabilities is the determination of the gamma-cascade detection efficiency. In Boutoux et al. (2013) [10] we developed the EXtrapolated Efficiency Method (EXEM), a new method to measure this quantity. In this work, we have applied, for the first time, the EXEM to infer the gamma-cascade detection efficiency in the actinide region. In particular, we have considered the "2"3"8U(d,p)"2"3"9U and "2"3"8U("3He,d)"2"3"9Np reactions. We have performed Hauser–Feshbach calculations to interpret our results and to verify the hypothesis on which the EXEM is based. The determination of fission and gamma-decay probabilities of "2"3"9Np below the neutron separation energy allowed us to validate the EXEM.

  17. Beta, but not gamma, band oscillations index visual form-motion integration.

    Directory of Open Access Journals (Sweden)

    Charles Aissani

    Full Text Available Electrophysiological oscillations in different frequency bands co-occur with perceptual, motor and cognitive processes but their function and respective contributions to these processes need further investigations. Here, we recorded MEG signals and seek for percept related modulations of alpha, beta and gamma band activity during a perceptual form/motion integration task. Participants reported their bound or unbound perception of ambiguously moving displays that could either be seen as a whole square-like shape moving along a Lissajou's figure (bound percept or as pairs of bars oscillating independently along cardinal axes (unbound percept. We found that beta (15-25 Hz, but not gamma (55-85 Hz oscillations, index perceptual states at the individual and group level. The gamma band activity found in the occipital lobe, although significantly higher during visual stimulation than during base line, is similar in all perceptual states. Similarly, decreased alpha activity during visual stimulation is not different for the different percepts. Trial-by-trial classification of perceptual reports based on beta band oscillations was significant in most observers, further supporting the view that modulation of beta power reliably index perceptual integration of form/motion stimuli, even at the individual level.

  18. Development of software for the determination of gamma ray detection efficiency

    International Nuclear Information System (INIS)

    Silva, Antonio C.O. da; Genezini, Frederico A.; Zahn, Guilherme S.

    2009-01-01

    Gamma spectrometry is frequently used as a tool in analytical chemistry or environmental analyses. The efficiency of the detection setup is one of most important steps of the analyses, but users don't always calculate their own efficiency curve because this procedure is not trivial, and therefore they adapt their measurement geometry to work in a setup that has been previously calibrated, which will often cause limitations. In order to solve this problem, a software was developed that helps a non-experienced user to compute the detection efficiency curve and to determine the detection efficiency at a given gamma-ray energy. (author)

  19. Gamma-index method sensitivity for gauging plan delivery accuracy of volumetric modulated arc therapy.

    Science.gov (United States)

    Park, Jong In; Park, Jong Min; Kim, Jung-In; Park, So-Yeon; Ye, Sung-Joon

    2015-12-01

    The aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT). Twenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose-volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences. Considerable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = -0.712, -0.628 and -0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose-volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria. Local gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Analytical calculations of the efficiency of gamma scintillators total efficiency for coaxial disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Selim, Y S; Abbas, M I; Fawzy, M A [Physics Department, Faculty of Science, Alexandria University, Aleaxndria (Egypt)

    1997-12-31

    Total efficiency of clad right circular cylindrical Nal(TI) scintillation detector from a coaxial isotropic radiating circular disk source has been calculated by the of rigid mathematical expressions. Results were tabulated for various gamma energies. 2 figs., 5 tabs.

  1. An efficiency study of a high resolution gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Marti Climent, J.M.

    1987-01-01

    A review of the different curves for the efficiency fit of a high resolution gamma-ray spectrometer was made. These curves are used to fit the efficiency of our detector system. In order to study the goodness of the different fits various standards were used, and the ICRP GAM-83 exercise results were employed. (author)

  2. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  3. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  4. Monitoring changes in economy-wide energy efficiency: From energy-GDP ratio to composite efficiency index

    International Nuclear Information System (INIS)

    Ang, B.W.

    2006-01-01

    Since the 1973 world oil crisis, monitoring trends in energy efficiency at the economy-wide level has been an important component of energy strategy in many countries. To support this effort, various energy efficiency-related indicators have been developed. We examine some classical indicators which are often found in national and international energy studies in the 1970s and 1980s. We then describe the recent developments in using the index decomposition analysis to give an economy-wide composite energy efficiency index based on a bottom-up approach. This composite index is superior to the classical indicators as an economy-wide energy efficiency measure and has lately been adopted by a growing number of countries for national energy efficiency trend monitoring

  5. Quantifying and improving the efficiency of Gamma Knife treatment plans for brain metastases: results of a 1-year audit.

    Science.gov (United States)

    Wright, Gavin; Hatfield, Paul; Loughrey, Carmel; Reiner, Beatrice; Bownes, Peter

    2014-12-01

    A method for quantifying the efficiency of Gamma Knife treatment plans for metastases was previously implemented by the authors to retrospectively identify the least efficient plans and has provided insights into improved planning strategies. The aim of the current work was to ascertain whether those insights led to improved treatment plans. Following completion of the initial study, a 1-year audit of metastasis plans created at St. James's Institute of Oncology was carried out. Audited recent plans were compared with the earlier plans of the initial study, in terms of their efficiency and dosimetric quality. The statistical significance of any differences between relevant plan parameters was quantified by Mann-Whitney U-tests. Comparisons were made between all plans and repeated for a reduced set of plans from which the smallest lesions treated with a single 4-mm shot were excluded. The plan parameters compared were a plan efficiency index (PEI), the number of shots, Paddick conformity index (PCI), gradient index (GI), and percent coverage (of the lesion by the prescription isodose). A total of 157 metastatic lesions were included in the audit and were compared with 241 in the initial study. In a comparison of all cases, the audited plans achieved a higher median PEI score than did the earlier plans from the initial study (1.08 vs 1.02), indicating improved efficiency of the audited plans. When the smallest lesions (for which there was little scope for varying plan strategy) were discounted, the improvement in median PEI score was greater (1.23 vs 1.03, p planning strategy yielding these efficiency improvements did not rely on the use of significantly fewer shots (median 11 vs 11 shots, p = 0.924), nor did it result in significant detriment to dosimetric quality (median coverage 99% vs 99%, median PCI 0.84 vs 0.83, p = 0.449, and median GI 2.72 vs 2.67, p = 0.701, audited plans vs initial plans, respectively). Choice of planning strategy can substantially affect

  6. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry

    International Nuclear Information System (INIS)

    Chagren, S.; Tekaya, M.Ben; Reguigui, N.; Gharbi, F.

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a “virtual” reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60–2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. - Highlights: • The GEANT4 code of CERN has been used to transfer the peak efficiency from point to points and voluminous detection configurations in HPGe gamma

  7. More Gamma More Predictions: Gamma-Synchronization as a Key Mechanism for Efficient Integration of Classical Receptive Field Inputs with Surround Predictions

    Science.gov (United States)

    Vinck, Martin; Bosman, Conrado A.

    2016-01-01

    During visual stimulation, neurons in visual cortex often exhibit rhythmic and synchronous firing in the gamma-frequency (30–90 Hz) band. Whether this phenomenon plays a functional role during visual processing is not fully clear and remains heavily debated. In this article, we explore the function of gamma-synchronization in the context of predictive and efficient coding theories. These theories hold that sensory neurons utilize the statistical regularities in the natural world in order to improve the efficiency of the neural code, and to optimize the inference of the stimulus causes of the sensory data. In visual cortex, this relies on the integration of classical receptive field (CRF) data with predictions from the surround. Here we outline two main hypotheses about gamma-synchronization in visual cortex. First, we hypothesize that the precision of gamma-synchronization reflects the extent to which CRF data can be accurately predicted by the surround. Second, we hypothesize that different cortical columns synchronize to the extent that they accurately predict each other’s CRF visual input. We argue that these two hypotheses can account for a large number of empirical observations made on the stimulus dependencies of gamma-synchronization. Furthermore, we show that they are consistent with the known laminar dependencies of gamma-synchronization and the spatial profile of intercolumnar gamma-synchronization, as well as the dependence of gamma-synchronization on experience and development. Based on our two main hypotheses, we outline two additional hypotheses. First, we hypothesize that the precision of gamma-synchronization shows, in general, a negative dependence on RF size. In support, we review evidence showing that gamma-synchronization decreases in strength along the visual hierarchy, and tends to be more prominent in species with small V1 RFs. Second, we hypothesize that gamma-synchronized network dynamics facilitate the emergence of spiking output that

  8. Plan Quality and Treatment Efficiency for Radiosurgery to Multiple Brain Metastases: Non-Coplanar RapidArc vs Gamma Knife

    Directory of Open Access Journals (Sweden)

    Haisong eLiu

    2016-02-01

    Full Text Available Objectives: This study compares the dosimetry and efficiency of two modern radiosurgery (SRS modalities for multiple brain metastases (Gamma Knife and LINAC-based RapidArc/volumetric modulated arc therapy, with a special focus on the comparison of low dose spread.Methods: Six patients with three or four small brain metastases were used in this study. The size of targets varied from 0.1 ~ 10.5 cc. SRS doses were prescribed according to size of lesions. SRS plans were made using both Gamma Knife® Perfexion and a single-isocenter, multiple non-coplanar RapidArc®. Dosimetric parameters analyzed included RTOG conformity index (CI, gradient index (GI, 12 Gy isodose volume (V12Gy for each target, and the dose spread (Dspread for each plan. Dspread reflects SRS plan’s capability of confining radiation to within the local vicinity of the lesion and to not spread out to the surrounding normal brain tissues. Each plan has a dose (Dspread, such that once dose decreases below Dspread (on total tissue DVH, isodose volume starts increasing dramatically. Dspread is defined as that dose when volume increase first exceeds 20 cc per 0.1 Gy dose decrease. Results: RapidArc SRS has smaller CI (1.19 ±0.14 vs. 1.50 ± 0.16, p<0.001 and larger GI (4.77 ± 1.49 vs. 3.65 ± 0.98, p <0.01. V12Gy results were comparable (2.73 ± 1.38 cc vs. 3.06 ± 2.20 cc, p = 0.58. Moderate to lower dose spread, V6, V4.5, and V3, were also equivalent. Gamma Knife plans achieved better very low dose spread (≤3 Gy and also had slightly smaller Dspread, 1.9 Gy vs 2.5 Gy. Total treatment time for Gamma Knife is estimated between 60~100 min. Gamma Knife treatments are between 3~5 times longer compared to RapidArc treatment techniques.Conclusion: Dosimetric parameters reflecting prescription dose conformality (CI, dose fall off (GI, radiation necrosis indicator (V12Gy, and dose spread (Dspread were compared between Gamma Knife SRS and RapidArc SRS for multi-mets. RapidArc plans have

  9. On the functional form of an efficiency index

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Keiding, Hans

    1998-01-01

    An input efficiency index gives a numeric assessment of the degree to which a given input combination falls short of being efficient in producing a fixed amount of output. This paper presents a system of axioms which characterise a certain family of efficiency indices containing the well-known Fa...

  10. Efficiency and effectiveness of gamma rays and sodium azide in Sesbania cannabina Poir

    International Nuclear Information System (INIS)

    Kumar, G.; Srivastava, N.

    2013-01-01

    Mutagenic effectiveness and efficiency is an important factor for the selection of a mutagen for a mutation breeding program. Mutagenic effectiveness is a measure of the frequency of mutations induced by a unit mutagen dose, while mutagenic efficiency is a measure of the proportion of mutations in relation to undesirable changes such as lethality, sterility, meiotic aberrations etc. The present study envisages the mutagenic effectiveness and efficiency of individual and combined treatments of chemical and physical mutagens i.e. sodium azide (individual), gamma rays (individual) and sodium azide + gamma ray (combined). For the individual treatment of sodium azide, the seeds of the Sesbania cannabina variety ND-1 were treated with 0.5% solution of sodium azide (SA) for four different time durations, i.e. 3, 5, 7, and 9 h, and for the individual treatment of gamma rays, dry and healthy seeds were treated with 20, 40, 60, and 80 Kr doses of gamma rays. For the combined treatment, the seeds were exposed to four different doses of gamma rays (20, 40, 60, and 80 Kr) and after irradiation seeds were treated with 0.5% solution of sodium azide for 3 h. After treatment, seeds subjected to individual and combined treatment were sown in randomized block design to raise the M 1 generation and a study was conducted on germination percentage, survival percentage, pollen fertility percentage, and chromosomal aberrations at different doses of the individual and combined treatments. (author)

  11. Thin film CdTe based neutron detectors with high thermal neutron efficiency and gamma rejection for security applications

    Energy Technology Data Exchange (ETDEWEB)

    Smith, L.; Murphy, J.W. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Kim, J. [Korean Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of); Rozhdestvenskyy, S.; Mejia, I. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Park, H. [Korean Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of); Allee, D.R. [Flexible Display Center, Arizona State University, Phoenix, AZ 85284 (United States); Quevedo-Lopez, M. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Gnade, B., E-mail: beg031000@utdallas.edu [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States)

    2016-12-01

    Solid-state neutron detectors offer an alternative to {sup 3}He based detectors, but suffer from limited neutron efficiencies that make their use in security applications impractical. Solid-state neutron detectors based on single crystal silicon also have relatively high gamma-ray efficiencies that lead to false positives. Thin film polycrystalline CdTe based detectors require less complex processing with significantly lower gamma-ray efficiencies. Advanced geometries can also be implemented to achieve high thermal neutron efficiencies competitive with silicon based technology. This study evaluates these strategies by simulation and experimentation and demonstrates an approach to achieve >10% intrinsic efficiency with <10{sup −6} gamma-ray efficiency.

  12. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.

    Science.gov (United States)

    Chagren, S; Tekaya, M Ben; Reguigui, N; Gharbi, F

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki

    2017-01-26

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverberation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is related to the difficult question of analyzing the statistics of a sum of Gamma- Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose robust importance sampling schemes that efficiently evaluates the outage probability of diversity receivers over Gamma-Gamma fading channels. The proposed estimators satisfy the well-known bounded relative error criterion for both maximum ratio combining and equal gain combining cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  14. The Effect of Gamma Irradiation on Yellowness Index (Y I) and Mechanical Properties in Plastic Food Packaging

    International Nuclear Information System (INIS)

    Tanhindarto, Rindy P.; I, Dian

    2002-01-01

    An experiment has been done for measuring the yellowness index (Yi) and mechanical properties at food packaging material was caused by gamma irradiation. The samples were obtained from the manufacture. There were three of samples with types of poly acrylonitrile copolymer, PVdC laminated biaxially oriented polypropylene and poly vinyl chloride films. Samples were irradiated at ambient temperature by gamma rays with the doses of 0 up to 100 kGy. Yellowness Index (Yi) of sample was carried out by using chromameter Hunter Lab system. while mechanical properties measuring by stragraph. The purpose of the present experiment was the yellowness index (Yi) and mechanical properties of food packaging material after and before the irradiation. The effects of I year storage on irradiated and unirradiated samples were also investigated. The results showed that best of three samples of plastic food packaging was poly acrylonitrile copolymer film because the Yellowness Index (Yi) and mechanical properties of poly acrylonitrile copolymer did not give any measurable change on the plastic treated by irradiation up to 100 kGy. Storage for 1 year gave some measurable changes of e Yellowness Index (Yi) and mechanical properties on all the samples examined

  15. Toward advanced gamma rays radiation resistance and shielding efficiency with phthalonitrile resins and composites

    Science.gov (United States)

    Derradji, Mehdi; Zegaoui, Abdeldjalil; Xu, Yi-Le; Wang, An-ran; Dayo, Abdul Qadeer; Wang, Jun; Liu, Wen-bin; Liu, Yu-Guang; Khiari, Karim

    2018-04-01

    The phthalonitrile resins have claimed the leading place in the field of high performance polymers thanks to their combination of outstanding properties. The present work explores for the first time the gamma rays radiation resistance and shielding efficiency of the phthalonitrile resins and its related tungsten-reinforced nanocomposites. The primary goal of this research is to define the basic behavior of the phthalonitrile resins under highly ionizing gamma rays. The obtained results confirmed that the neat phthalonitrile resins can resist absorbed doses as high as 200 kGy. Meanwhile, the remarkable shielding efficiency of the phthalonitrile polymers was confirmed to be easily improved by preparing lead-free nanocomposites. In fact, the gamma rays screening ratio reached the exceptional value of 42% for the nanocomposites of 50 wt% of nano-tungsten loading. Thus, this study confirms that the remarkable performances of the phthalonitrile resins are not limited to the thermal and mechanical properties and can be extended to the gamma rays radiation and shielding resistances.

  16. Evaluation of the radiobiological gamma index with motion interplay in tangential IMRT breast treatment

    Science.gov (United States)

    Sumida, Iori; Yamaguchi, Hajime; Das, Indra J.; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yamada, Yuji; Tamari, Kiesuke; Suzuki, Osamu; Seo, Yuji; Isohashi, Fumiaki; Yoshioka, Yasuo; Ogawa, Kazuhiko

    2016-01-01

    The purpose of this study was to evaluate the impact of the motion interplay effect in early-stage left-sided breast cancer intensity-modulated radiation therapy (IMRT), incorporating the radiobiological gamma index (RGI). The IMRT dosimetry for various breathing amplitudes and cycles was investigated in 10 patients. The predicted dose was calculated using the convolution of segmented measured doses. The physical gamma index (PGI) of the planning target volume (PTV) and the organs at risk (OAR) was calculated by comparing the original with the predicted dose distributions. The RGI was calculated from the PGI using the tumor control probability (TCP) and the normal tissue complication probability (NTCP). The predicted mean dose and the generalized equivalent uniform dose (gEUD) to the target with various breathing amplitudes were lower than the original dose (P < 0.01). The predicted mean dose and gEUD to the OARs with motion were higher than for the original dose to the OARs (P < 0.01). However, the predicted data did not differ significantly between the various breathing cycles for either the PTV or the OARs. The mean RGI gamma passing rate for the PTV was higher than that for the PGI (P < 0.01), and for OARs, the RGI values were higher than those for the PGI (P < 0.01). The gamma passing rates of the RGI for the target and the OARs other than the contralateral lung differed significantly from those of the PGI under organ motion. Provided an NTCP value <0.05 is considered acceptable, it may be possible, by taking breathing motion into consideration, to escalate the dose to achieve the PTV coverage without compromising the TCP. PMID:27534793

  17. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki

    2016-06-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion, a well-desired property characterizing the robustness of importance sampling schemes, for both identically and non-identically independent distributed cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  18. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki; Ben Rached, Nadhir; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2016-01-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion, a well-desired property characterizing the robustness of importance sampling schemes, for both identically and non-identically independent distributed cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  19. Efficient Outage Probability Evaluation of Diversity Receivers Over Generalized Gamma Channels

    KAUST Repository

    Ben Issaid, Chaouki

    2016-10-01

    In this paper, we are interested in determining the cumulative distribution function of the sum of generalized Gamma in the setting of rare event simulations. To this end, we present an efficient importance sampling estimator. The main result of this work is the bounded relative property of the proposed estimator. This result is used to accurately estimate the outage probability of multibranch maximum ratio combining and equal gain combining diversity receivers over generalized Gamma fading channels. Selected numerical simulations are discussed to show the robustness of our estimator compared to naive Monte Carlo.

  20. Efficient Outage Probability Evaluation of Diversity Receivers Over Generalized Gamma Channels

    KAUST Repository

    Ben Issaid, Chaouki; Alouini, Mohamed-Slim; Tempone, Raul

    2016-01-01

    In this paper, we are interested in determining the cumulative distribution function of the sum of generalized Gamma in the setting of rare event simulations. To this end, we present an efficient importance sampling estimator. The main result of this work is the bounded relative property of the proposed estimator. This result is used to accurately estimate the outage probability of multibranch maximum ratio combining and equal gain combining diversity receivers over generalized Gamma fading channels. Selected numerical simulations are discussed to show the robustness of our estimator compared to naive Monte Carlo.

  1. Development of source-less efficiency calibration procedure for CeBr3 based gamma spectrometry system

    International Nuclear Information System (INIS)

    Verma, Amit K.; Narayani, K.; Pant, Amar D.; Bhosale, Nitin; Anilkumar, S.; Palani Selvam, T.

    2018-01-01

    Scintillation spectrometers are widely used in detection and spectrometry of gamma photons. Sodium Iodide (NaI(Tl)) is the most commonly used scintillation detector for gamma ray spectrometry. However for portable application that require higher efficiency and better resolution Cerium Bromide (CeBr 3 ) crystals are more suitable than NaI(Tl) crystals. CeBr 3 detectors have high light output (∼ 68,000 photons/MeV), good proportionality, fast response and better energy resolution (<4% for 662 keV of 137 Cs), which makes it very promising detector for gamma ray spectrometry. In the present work, experimental and Monte Carlo based efficiencies for CeBr 3 detector for 137 Cs and 60 Co were evaluated

  2. Gamma Knife

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Gamma Knife Gamma Knife® is a radiation therapy that uses computerized ... If you're scheduled for radiation therapy using Gamma Knife®, a treatment team consisting of a radiation ...

  3. Efficient Joins with Compressed Bitmap Indexes

    Energy Technology Data Exchange (ETDEWEB)

    Computational Research Division; Madduri, Kamesh; Wu, Kesheng

    2009-08-19

    We present a new class of adaptive algorithms that use compressed bitmap indexes to speed up evaluation of the range join query in relational databases. We determine the best strategy to process a join query based on a fast sub-linear time computation of the join selectivity (the ratio of the number of tuples in the result to the total number of possible tuples). In addition, we use compressed bitmaps to represent the join output compactly: the space requirement for storing the tuples representing the join of two relations is asymptotically bounded by min(h; n . cb), where h is the number of tuple pairs in the result relation, n is the number of tuples in the smaller of the two relations, and cb is the cardinality of the larger column being joined. We present a theoretical analysis of our algorithms, as well as experimental results on large-scale synthetic and real data sets. Our implementations are efficient, and consistently outperform well-known approaches for a range of join selectivity factors. For instance, our count-only algorithm is up to three orders of magnitude faster than the sort-merge approach, and our best bitmap index-based algorithm is 1.2x-80x faster than the sort-merge algorithm, for various query instances. We achieve these speedups by exploiting several inherent performance advantages of compressed bitmap indexes for join processing: an implicit partitioning of the attributes, space-efficiency, and tolerance of high-cardinality relations.

  4. Efficient electron heating in relativistic shocks and gamma-ray-burst afterglow.

    Science.gov (United States)

    Gedalin, M; Balikhin, M A; Eichler, D

    2008-02-01

    Electrons in shocks are efficiently energized due to the cross-shock potential, which develops because of differential deflection of electrons and ions by the magnetic field in the shock front. The electron energization is necessarily accompanied by scattering and thermalization. The mechanism is efficient in both magnetized and nonmagnetized relativistic electron-ion shocks. It is proposed that the synchrotron emission from the heated electrons in a layer of strongly enhanced magnetic field is responsible for gamma-ray-burst afterglows.

  5. Study on the Effects of Sample Density on Gamma Spectrometry System Measurement Efficiency at Radiochemistry and Environment Laboratory

    International Nuclear Information System (INIS)

    Wo, Y.M.; Dainee Nor Fardzila Ahmad Tugi; Khairul Nizam Razali

    2015-01-01

    The effects of sample density on the measurement efficiency of the gamma spectrometry system were studied by using four sets multi nuclide standard sources of various densities between 0.3 - 1.4 g/ ml. The study was conducted on seven unit 25 % coaxial HPGe detector gamma spectrometry systems in Radiochemistry and Environment Laboratory (RAS). Difference on efficiency against gamma emitting radionuclides energy and measurement systems were compared and discussed. Correction factor for self absorption caused by difference in sample matrix density of the gamma systems were estimated. The correction factors are to be used in quantification of radionuclides concentration in various densities of service and research samples in RAS. (author)

  6. Disinfection of secondary effluent by gamma radiation inactivation efficiency and regrowth

    International Nuclear Information System (INIS)

    Sekiguchi, M.; Sawai, T.; Shimokawa, T.; Sawai, T.

    1992-01-01

    Inactivation efficiencies of several microorganisms in secondary effluents (SE) from sewage treatment plants by gamma radiation were investigated. Escherichia coli, Klebsiella pneumoniae and Enterobacter cloacae inoculated in SE were very sensitive but Streptcoccus sp. was resistant to gamma radiation. In addition, no significant difference was found between the combined sewer system and the separate sewer system in regards to the inactivation efficiencies of the bacteria inoculated in the SE. The number of total bacteria in SE was rapidly decreased in the dose range of 0 to 0.2-0.3 kGy but the number gradually fell over the dose range. Moreover, the number of total coliforms almost exponentially decreased with increasing dose, and fell to undetectable levels at about 0.5 kGy. Because of the decrease of the initial bacteria number in SE, adequate filtrating treatments were effective in lowering the irradiation dose for disinfection. Further, the effects of filtrating treatment on bacteria regrowth in SE are discussed. (author)

  7. Efficient protein structure search using indexing methods.

    Science.gov (United States)

    Kim, Sungchul; Sael, Lee; Yu, Hwanjo

    2013-01-01

    Understanding functions of proteins is one of the most important challenges in many studies of biological processes. The function of a protein can be predicted by analyzing the functions of structurally similar proteins, thus finding structurally similar proteins accurately and efficiently from a large set of proteins is crucial. A protein structure can be represented as a vector by 3D-Zernike Descriptor (3DZD) which compactly represents the surface shape of the protein tertiary structure. This simplified representation accelerates the searching process. However, computing the similarity of two protein structures is still computationally expensive, thus it is hard to efficiently process many simultaneous requests of structurally similar protein search. This paper proposes indexing techniques which substantially reduce the search time to find structurally similar proteins. In particular, we first exploit two indexing techniques, i.e., iDistance and iKernel, on the 3DZDs. After that, we extend the techniques to further improve the search speed for protein structures. The extended indexing techniques build and utilize an reduced index constructed from the first few attributes of 3DZDs of protein structures. To retrieve top-k similar structures, top-10 × k similar structures are first found using the reduced index, and top-k structures are selected among them. We also modify the indexing techniques to support θ-based nearest neighbor search, which returns data points less than θ to the query point. The results show that both iDistance and iKernel significantly enhance the searching speed. In top-k nearest neighbor search, the searching time is reduced 69.6%, 77%, 77.4% and 87.9%, respectively using iDistance, iKernel, the extended iDistance, and the extended iKernel. In θ-based nearest neighbor serach, the searching time is reduced 80%, 81%, 95.6% and 95.6% using iDistance, iKernel, the extended iDistance, and the extended iKernel, respectively.

  8. Assessing sample attenuation parameters for use in low-energy efficiency transfer in gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Bruggeman, M.; Verheyen, L.; Vidmar, T.; Liu, B.

    2016-01-01

    We present a numerical fitting method for transmission data that outputs an equivalent sample composition. This output is used as input to a generalised efficiency transfer model based on the EFFTRAN software integrated in a LIMS. The procedural concept allows choosing between efficiency transfer with a predefined sample composition or with an experimentally determined composition based on a transmission measurement. The method can be used for simultaneous quantification of low-energy gamma emitters like "2"1"0Pb, "2"4"1Am, "2"3"4Th in typical environmental samples. - Highlights: • New fitting method for experimentally determined attenuation coefficients. • Generalised efficiency transfer with EFFTRAN based on transmission measurements. • Method of generalized efficiency transfer integrated in LIMS. • Method applicable to gamma-ray spectrometry of environmental samples.

  9. Gamma index evaluation of IMRT technique using gafchromic film EBT3 for homogeneous and inhomogeneous material

    Science.gov (United States)

    Nisauf, T. A.; Wibowo, W. E.; Pawiro, S. A.

    2017-07-01

    This study was done to evaluate the gamma index for registering between the planar of dose planning and the measurement of EBT film. The treatment plan was simulated for 5 patients using Fan Beam Computerized Tomography (FBCT) modality, Philips Pinnacle planning system, 6 MV photon energy, 50 segments IMRT technique, and calculation grid resolution (CGR) of 0.2 cm. Gamma Index (GI) evaluation was done with criteria of dose difference (DD) of 2 %, dose to agreement (DTA) of 2 mm and dose difference (DD) of 5 % DTA of 3 mm, SAD 100 cm, depth of 5 cm and 10 cm of the phantom. The result shows that GI for homogeneous material is greater than for inhomogeneous material with discrepancy to previous work is about 1.98 % for homogeneous material (depth 5 cm) and 2.05 % (depth 10 cm) while it was found of 2.98 % for inhomogeneous material (equivalent depth 5 cm) and 4.59 % (equivalent depth 10 cm).

  10. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  11. Hippocampal gamma-band Synchrony and pupillary responses index memory during visual search.

    Science.gov (United States)

    Montefusco-Siegmund, Rodrigo; Leonard, Timothy K; Hoffman, Kari L

    2017-04-01

    Memory for scenes is supported by the hippocampus, among other interconnected structures, but the neural mechanisms related to this process are not well understood. To assess the role of the hippocampus in memory-guided scene search, we recorded local field potentials and multiunit activity from the hippocampus of macaques as they performed goal-directed search tasks using natural scenes. We additionally measured pupil size during scene presentation, which in humans is modulated by recognition memory. We found that both pupil dilation and search efficiency accompanied scene repetition, thereby indicating memory for scenes. Neural correlates included a brief increase in hippocampal multiunit activity and a sustained synchronization of unit activity to gamma band oscillations (50-70 Hz). The repetition effects on hippocampal gamma synchronization occurred when pupils were most dilated, suggesting an interaction between aroused, attentive processing and hippocampal correlates of recognition memory. These results suggest that the hippocampus may support memory-guided visual search through enhanced local gamma synchrony. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Gamma-ray spectrometer system with high efficiency and high resolution

    International Nuclear Information System (INIS)

    Moss, C.E.; Bernard, W.; Dowdy, E.J.; Garcia, C.; Lucas, M.C.; Pratt, J.C.

    1983-01-01

    Our gamma-ray spectrometer system, designed for field use, offers high efficiency and high resolution for safeguards applications. The system consists of three 40% high-purity germanium detectors and a LeCroy 3500 data acquisition system that calculates a composite spectrum for the three detectors. The LeCroy 3500 mainframe can be operated remotely from the detector array with control exercised through modems and the telephone system. System performance with a mixed source of 125 Sb, 154 Eu, and 155 Eu confirms the expected efficiency of 120% with the overall resolution showing little degradation over that of the worst detector

  13. Quantitative estimations of the efficiency of stabilization and lowering of background in gamma-spectrometry of environment samples

    International Nuclear Information System (INIS)

    Pop, O.M.; Stets, M.V.; Maslyuk, V.T.

    2015-01-01

    We consider a gamma-spectrometric complex of IEP of the NAS of Ukraine, where a passive multilayer external defense is used (complex has been made in 1989). We have developed and investigated a system of stability and lowering of background in the gamma-spectrometric complex. As metrological coefficients, the efficiency factor of defense are considered, the calculation and analysis of which show that their values are different for different energies of gamma-quanta and gamma-active nuclides

  14. Study on direct determination of uranium and efficient equilibrium factor by gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Liu Chunkui

    1990-01-01

    The test principle, test set and surveying methods for conducting gamma-ray spectrometry on conveyer are presented. The conversion coefficient of the spectrometer has been found by using duallinear regression analysis of uranium and radon and their higher and lower bands of gamma-ray spectra. The efficient equilibrium factor can be quickly determined, and the direct determination of uranium in the non-equilibrium condition of uranium and radium can be made

  15. A combined sustainability index for electricity efficiency measures

    International Nuclear Information System (INIS)

    Goldrath, T.; Ayalon, O.; Shechter, M.

    2015-01-01

    One of the most substantial tools that serve decision makers in their efforts to reduce greenhouse gas emissions includes energy efficiency measures that in most cases benefit from governmental assistance for achieving electricity consumption reduction goals. This paper examines five energy efficiency measures, defining a combined sustainability index. A multi-criteria analysis of five predefined indices was developed (economic, environmental, technology, social and political), providing a combined index for each measure and a tool for identifying the preferred measure within a specific situation, based on its total sustainability score. In this research, a case study was conducted and the preferred measure was found to be municipal street lighting systems, based on its high political and social scores, and its relatively high installation potential. The second choice would be replacement of chillers in the industrial sector, and the least favorable measure is the replacement of water pumps in the water sector. The methodology described brings into account the technological specifications of the measure implemented, and the specific national conditions under which it is implemented. - Highlights: • A MCDA of five indices was developed to define a combined sustainability index. • Criteria defined were environment, technology, economy, social and political. • Five energy efficiency measures were rated, based on their total sustainability score. • Measures were in five main electricity consumption sectors. • The preferred measure found in the case study was municipal street lighting systems.

  16. THE SPECTRAL INDEX PROPERTIES OF FERMI BLAZARS

    Energy Technology Data Exchange (ETDEWEB)

    Fan, J. H.; Yang, J. H.; Yuan, Y. H.; Wang, J.; Gao, Y., E-mail: jhfan_cn@yahoo.com.cn [Center for Astrophysics, Guangzhou University, Guangzhou 510006 (China)

    2012-12-20

    In this paper, a sample of 451 blazars (193 flat spectrum radio quasars (FSRQs), 258 BL Lacertae objects) with corresponding X-ray and Fermi {gamma}-ray data is compiled to investigate the correlation both between the X-ray spectral index and the {gamma}-ray spectral index and between the spectral index and the luminosity, and to compare the spectral indexes {alpha}{sub X}, {alpha}{sub {gamma}}, {alpha}{sub X{gamma}}, and {alpha}{sub {gamma}X{gamma}} for different subclasses. We also investigated the correlation between the X-ray and the {gamma}-ray luminosity. The following results have been obtained. Our analysis indicates that an anti-correlation exists between the X-ray and the {gamma}-ray spectral indexes for the whole sample. However, when we considered the subclasses of blazars (FSRQs, the low-peaked BL Lacertae objects (LBLs) and the high-peaked BL Lacertae objects (HBLs)) separately, there is not a clear relationship for each subclass. Based on the Fermi-detected sources, we can say that the HBLs are different from FSRQs, while the LBLs are similar to FSRQs.

  17. SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, S [Aga Khan University Hospital, Karachi, Sindh (Pakistan); Ahmed, S [Pakistan Inst of Eng Applied Sciences, Islamabad (Pakistan); Ahmed, F; Hussain, A

    2016-06-15

    Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and plan quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.

  18. SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

    International Nuclear Information System (INIS)

    Ahmed, S; Ahmed, S; Ahmed, F; Hussain, A

    2016-01-01

    Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and plan quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.

  19. Fast and efficient indexing approach for object recognition

    Science.gov (United States)

    Hefnawy, Alaa; Mashali, Samia A.; Rashwan, Mohsen; Fikri, Magdi

    1999-08-01

    This paper introduces a fast and efficient indexing approach for both 2D and 3D model-based object recognition in the presence of rotation, translation, and scale variations of objects. The indexing entries are computed after preprocessing the data by Haar wavelet decomposition. The scheme is based on a unified image feature detection approach based on Zernike moments. A set of low level features, e.g. high precision edges, gray level corners, are estimated by a set of orthogonal Zernike moments, calculated locally around every image point. A high dimensional, highly descriptive indexing entries are then calculated based on the correlation of these local features and employed for fast access to the model database to generate hypotheses. A list of the most candidate models is then presented by evaluating the hypotheses. Experimental results are included to demonstrate the effectiveness of the proposed indexing approach.

  20. Methods for fitting of efficiency curves obtained by means of HPGe gamma rays spectrometers

    International Nuclear Information System (INIS)

    Cardoso, Vanderlei

    2002-01-01

    The present work describes a few methodologies developed for fitting efficiency curves obtained by means of a HPGe gamma-ray spectrometer. The interpolated values were determined by simple polynomial fitting and polynomial fitting between the ratio of experimental peak efficiency and total efficiency, calculated by Monte Carlo technique, as a function of gamma-ray energy. Moreover, non-linear fitting has been performed using a segmented polynomial function and applying the Gauss-Marquardt method. For the peak area obtainment different methodologies were developed in order to estimate the background area under the peak. This information was obtained by numerical integration or by using analytical functions associated to the background. One non-calibrated radioactive source has been included in the curve efficiency in order to provide additional calibration points. As a by-product, it was possible to determine the activity of this non-calibrated source. For all fittings developed in the present work the covariance matrix methodology was used, which is an essential procedure in order to give a complete description of the partial uncertainties involved. (author)

  1. Calculating concentration of inhaled radiolabeled particles from external gamma counting: External counting efficiency and attenuation coefficient of thorax

    International Nuclear Information System (INIS)

    Langenback, E.G.; Foster, W.M.; Bergofsky, E.H.

    1989-01-01

    We determined the overall external counting efficiency of radiolabeled particles deposited in the sheep lung. This efficiency permits the noninvasive calculation of the number of particles and microcuries from gamma-scintillation lung images of the live sheep. Additionally, we have calculated the attenuation of gamma radiation (120 keV) by the posterior chest wall and the gamma-scintillation camera collection efficiency of radiation emitted from the lung. Four methods were employed in our experiments: (1) by light microscopic counting of discrete carbonized polystyrene particles with a count median diameter (CMD) of 2.85 microns and tagged with cobalt-57, we delineated a linear relationship between the number of particles and the emitted counts per minute (cpm) detected by well scintillation counting; (2) from this conversion relationship we determined the number of particles inhaled and deposited in the lungs by scintillation counting fragments of dissected lung at autopsy; (3) we defined a linear association between the number of particles or microcuries contained in the lung and the emitted radiation as cpm detected by a gamma scintillation camera in the live sheep prior to autopsy; and (4) we compared the emitted radiation from the lungs of the live sheep to that of whole excised lungs in order to calculate the attenuation coefficient (ac) of the chest wall. The mean external counting efficiency was 4.00 X 10(4) particles/cpm (5.1 X 10(-3) microCi/cpm), the camera collection efficiency was 1 cpm/10(4) disintegrations per minute (dpm), and the ac had a mean of 0.178/cm. The external counting efficiency remained relatively constant over a range of particles and microcuries, permitting a more general use of this ratio to estimate number of particles or microcuries depositing after inhalation in a large mammalian lung if a similarly collimated gamma camera system is used

  2. The efficient neutron-gamma pulse shape discrimination with small active volume scintillation detector

    International Nuclear Information System (INIS)

    Phan Van Chuan; Nguyen Duc Hoa; Nguyen Xuan Hai; Nguyen Ngoc Anh; Tuong Thi Thu Huong; Nguyen Nhi Dien; Pham Dinh Khang

    2016-01-01

    A small detector with EJ-301 liquid scintillation was manufactured for the study on the neutron-gamma pulse shape discrimination. In this research, four algorithms, including Threshold crossing time (TCT), Pulse gradient analysis (PGA), Charge comparison method (CCM), and Correlation pattern recognition (CPR) were developed and compared in terms of their discrimination effectiveness between neutrons and gamma rays. The figures of merits (FOMs) obtained for 100 ÷ 2000 keVee (keV energy electron equivalent) neutron energy range show the charge comparison method was the most efficient of the four algorithms. (author)

  3. Mutagenic effectiveness and efficiency of EMS, sodium azide and gamma radiation in chickpea (Cicer arietinum L.)

    International Nuclear Information System (INIS)

    Barshile, J.D.; Apparao, B.J.

    2006-01-01

    Mutagenic effectiveness and efficiency of Ethyl Methane Sulphonate (EMS), Sodium Azide (SA) and gamma radiation on two cultivars of chickpea (Cicer arietinum L), Vijay and Vishwas were evaluated by the biological damages caused by them in M 1 generation and on the basis of frequency of chlorophyll mutations produced in the M 2 generation. All mutagenic treatments of EMS, SA and gamma radiation decreased germination, seedling height, plant survival and pollen fertility in both the cultivars. The extent of effect was dose dependent. LD 50 values of mutagen were found to be helpful for planning experimental mutagenesis in chickpea. Frequency of chlorophyll mutations in M 2 generation was less in Vijay as compared to Vishwas. Mutagenic effectiveness is inversely proportional to the increasing concentrations/doses of mutagens in both the cultivars, except for gamma radiation treatments in the cultivar Vishwas. All three mutagens (except EMS in the Vijay and gamma radiation in the cultivar Vishwas) exhibited gradual decrease in mutagenic efficiency, with an increase in their concentration/dose. (author)

  4. Efficient Indexing of the Historical, Present, and Future Positions of Moving Objects

    DEFF Research Database (Denmark)

    Lin, D.; Jensen, Christian Søndergaard; Ooi, B.C.

    2005-01-01

    Although significant effort has been put into the development of efficient spatio-temporal indexing techniques for moving objects, little attention has been given to the development of techniques that efficiently support queries about the past, present, and future positions of objects...... time. The index stores linearized moving-object locations in a forest of B+-trees. The index supports queries that select objects based on temporal and spatial constraints, such as queries that retrieve all objects whose positions fall within a spatial range during a set of time intervals. Empirical...

  5. Full energy peak efficiency of composite detectors for high energy gamma-rays

    International Nuclear Information System (INIS)

    Kshetri, Ritesh

    2015-01-01

    Experiments involving radioactive beams demand high detection efficiencies. One of the ways to obtain high detection efficiency without deteriorating the energy resolution or timing characteristics is the use of composite detectors which are composed of standard HPGe crystals arranged in a compact way. Two simplest composite detectors are the clover and cluster detectors. The TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS) comprises of 16 large volume, 32-fold segmented HPGe clover detectors, where each detector is shielded by a 20-fold segmented escape suppression shield (ESS)

  6. Efficient approximation of the incomplete gamma function for use in cloud model applications

    Directory of Open Access Journals (Sweden)

    U. Blahak

    2010-07-01

    Full Text Available This paper describes an approximation to the lower incomplete gamma function γl(a,x which has been obtained by nonlinear curve fitting. It comprises a fixed number of terms and yields moderate accuracy (the absolute approximation error of the corresponding normalized incomplete gamma function P is smaller than 0.02 in the range 0.9 ≤ a ≤ 45 and x≥0. Monotonicity and asymptotic behaviour of the original incomplete gamma function is preserved.

    While providing a slight to moderate performance gain on scalar machines (depending on whether a stays the same for subsequent function evaluations or not compared to established and more accurate methods based on series- or continued fraction expansions with a variable number of terms, a big advantage over these more accurate methods is the applicability on vector CPUs. Here the fixed number of terms enables proper and efficient vectorization. The fixed number of terms might be also beneficial on massively parallel machines to avoid load imbalances, caused by a possibly vastly different number of terms in series expansions to reach convergence at different grid points. For many cloud microphysical applications, the provided moderate accuracy should be enough. However, on scalar machines and if a is the same for subsequent function evaluations, the most efficient method to evaluate incomplete gamma functions is perhaps interpolation of pre-computed regular lookup tables (most simple example: equidistant tables.

  7. Gamma ray, EMS and sodium azide induced effectiveness and efficiency of chlorophyll mutations in basmati rice (Oryza sativa L.)

    International Nuclear Information System (INIS)

    Singh, Sanjeev; Singh, J.; Singh, R.K.

    2001-01-01

    The effectiveness and efficiency of gamma ray, EMS, sodium azide alone or in combination in relation to chlorophyll mutations in two varieties of Basmati rice (Oryza sativa L.) in M 2 generation were studied. The chlorophyll mutations were induced by all the doses of mutagens alone or in combination relatively at a fair frequency in both the varieties in M 2 generation. In general, it was found that combination treatments of gamma rays and EMS were observed to be more efficient in Taraori Basmati, while EMS alone and combination treatment of gamma rays and EMS were more efficient in Pusa Basmati 1 on sterility and growth injury basis both. Sodium azide at 0.5 mM was found as the most effective dose in both Taraori Basmati and Pusa Basmati 1 cultivars. (author)

  8. Multielement CdZnTe detectors for high-efficiency, ambient-temperature gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Moss, C.E.; Sweet, M.R.; Ianakiev, K.; Reedy, R.C.; Li, J.; Valentine, J.D.

    1998-01-01

    CdZnTe is an attractive alternative to scintillator-based technology for ambient-temperature, gamma-ray spectroscopy. Large, single-element devices up to 3500 mm 3 have been developed for gamma-ray spectroscopy and are now available commercially. Because CdZnTe is a wide band-gap semiconductor, it can operate over a wide range of ambient temperatures with minimal power consumption. Over this range, CdZnTe detectors routinely yield better overall performance for gamma-ray spectroscopy than scintillator detectors. Manufacturing issues and material electronic properties limit the maximum size of single-element CdZnTe detectors. The authors are investigating methods to combine CdZnTe detectors together to improve detection efficiency and overall performance of gamma-ray spectroscopy. The applications include the assay and identification of radioisotopes for nuclear material safeguards and nonproliferation (over the energy range 50 keV to 1 MeV), and the analysis of elemental composition for planetary science (over the energy range 1 MeV to 10 MeV). Design issues for the two energy ranges are summarized

  9. A comment on the calculation of the total-factor energy efficiency (TFEE) index

    International Nuclear Information System (INIS)

    Chang, Ming-Chung

    2013-01-01

    This study provides a no-output growth model to conveniently calculate the total-factor energy efficiency (TFEE) index originally proposed by Hu and Wang (2006). The TFEE index serves as a very well-known and popular means of estimating overall energy efficiency. While many previous studies have used the indicator of energy inefficiency, including the indicator of energy intensity (i.e., Energy input/Gross Domestic Product (GDP)) to measure energy efficiency, Hu and Kao (2007) point out that the indicator of energy intensity is not only a partial-factor energy efficiency indicator, but that this partial-factor ratio is also quite inappropriate for analyzing the impact of changing energy use over time. The TFEE index overcomes the disadvantage of the indicator of energy intensity as mentioned above, but five steps are needed to calculate the TFEE score. In this study, we provide a no-output growth model to conveniently calculate the TFEE score. Furthermore, we extend this no-output growth model to an output growth model. This study concludes that the output growth model not only makes it easier to calculate the TFEE index than the model proposed by Hu and Wang (2006) and Hu and Kao (2007), but that it can also obtain better TFEE scores. - Highlights: ► The comment is on the total-factor energy efficiency (TFEE) index. ► Two extension models are no-output growth model and output growth model. ► The model in this study makes it easier to calculate the TFEE index.

  10. The use of energy analysis and indexes of energy efficiency in nuclear power

    International Nuclear Information System (INIS)

    D'yakonov, E.I.; Ignatenko, E.I.

    1991-01-01

    The results of calculating the indexes of energy efficiency for NPPs with the WWER-1000 and RBMK-1000 reactors, heat and power NPPs with the WWER-1000 and dictrict heating NPPs with the AST-500 reactor in three fuel cycles, namely, the open one and with uranium and plutonium recycles, are considered. Complex account for the quantity and quality of produced and consumed energy provides for objective evaluation of the indexes of energy efficiency during comparative analysis of nuclear power plants with different types of reactors. It is shown that complex use of the energy produced at a NPP provides for increase of indexes of energy efficiency. The highest indexes are obtained for heat and power NPP with the WWER-1000 reactor in the open fuel cycle, with uranium and plutonium recycle and for NPP with the WWER-1000 reactor with plutonium recycle

  11. Mutagenic effectiveness and efficiency of gamma rays and ethyl methanesulhonate in Indian mustard

    International Nuclear Information System (INIS)

    Prasad, Rajendra; Singh, Basudeo

    1986-01-01

    Mutagenic effectiveness is a measure of the frequency of mutations induced by unit dose of a mutagen while mutagenic efficiency gives the proportion of mutations in relation to other associated undesirable biological effects such as gross chromosomal aberrations, lethality and sterility induced by the mutagen in question (Konzak, et al., 1965). The usefulness of any mutagen in plant breeding depends not only on its mutagenic effectiveness but also on its mutagenic efficiency. The efficiency and effectiveness of ethyl methanesulphonate (EMS) in relation to gamma rays in Indian mustard [Brassica juncea (L.) Czern and Coss] was studied. (author)

  12. Design of a software for gamma detector efficiency

    International Nuclear Information System (INIS)

    Lopez, G.

    2011-01-01

    Gamma spectroscopy with highly-pure-germanium detector is one of the most used method for qualitative and quantitative analysis of samples. Nevertheless Gamma spectroscopy results require to be corrected, first for taking into account the self-shielding effect that represents the absorption of the photons by the sample itself and secondly for correcting the fact that 2 photons emitted simultaneously with energy E 1 and E 2 are likely to be simultaneously detected and then counted as a single photon with an energy E 1 +E 2 . This effect is called gamma-gamma coincidence. A software has been designed to simulate both effect and produce correcting factors in the case of cylindrical geometries. This software has been validated on Americium 241 for the self-shielding effect and on Cesium 134 for gamma-gamma coincidence. (A.C.)

  13. Effect of refraction index and thickness of the light guide in the position-sensitive gamma-ray detector using compact PS-PMTs

    International Nuclear Information System (INIS)

    Inoue, K.; Saito, H.; Nagashima, Y.; Hyodo, T.; Nagai, Y.; Muramatsu, S.; Nagai, S.

    2000-01-01

    We constructed a position-sensitive gamma-ray detector consisting of an array of BGO scintillators, a light guide and compact PS-PMTs. The effects of refractive index and thickness of the light guide of a glass plate on the detector performance were investigated. A light guide with higher refractive index and smaller thickness is found better for a good spatial resolution.

  14. Selection of index complex for the NPP operator activity efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Kolesnik, A I; Chertorizhskij, E A

    1984-01-01

    Preconditions for choice of NPP operator activity efficiency index are determined. Results of the choice are given and a method for determination of generalized and particular parameters by means of which NPP operator activity efficiency can be estimated is considered. An algorithm of diagnosis of reason for unsuccess of operator activity based on assessment of psychological factors of complicacy is suggested.

  15. A simple and efficient gamma irradiator for RVNRL

    Energy Technology Data Exchange (ETDEWEB)

    Smolko, E; Ferenaz, G; Docters, E [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Makuuchi, Keizo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-12-31

    This work describes a new design of a gamma irradiator for RVNRL which obeys a reliable operation and an efficient economical equation. Our irradiator is of a nobel design according to present requirements of latex industries and to the state of the art of radiation technology. The irradiator is of a wet storage type, where the radioactive sources are fixed in the reactor vessel, permanently submerged in deionized water. Preformulated latex is pumped from a deposited vessel into the reactor vessel and it is recirculated during the irradiation cycle avoiding turbulences and dose inhomogeneities. The irradiation time per one ton batch with a Co-60 charge of 3.5E15 Bq (100 kCi) is of approximately 4 hours

  16. A simple and efficient gamma irradiator for RVNRL

    International Nuclear Information System (INIS)

    Smolko, E.; Ferenaz, G.; Docters, E.; Keizo Makuuchi

    1996-01-01

    This work describes a new design of a gamma irradiator for RVNRL which obeys a reliable operation and an efficient economical equation. Our irradiator is of a nobel design according to present requirements of latex industries and to the state of the art of radiation technology. The irradiator is of a wet storage type, where the radioactive sources are fixed in the reactor vessel, permanently submerged in deionized water. Preformulated latex is pumped from a deposited vessel into the reactor vessel and it is recirculated during the irradiation cycle avoiding turbulences and dose inhomogeneities. The irradiation time per one ton batch with a Co-60 charge of 3.5E15 Bq (100 kCi) is of approximately 4 hours

  17. AP Index

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Planetary Amplitude index - Bartels 1951. The a-index ranges from 0 to 400 and represents a K-value converted to a linear scale in gammas (nanoTeslas)--a scale that...

  18. Human Development Index and Efficiency level of Social Security Hospitals

    Directory of Open Access Journals (Sweden)

    H. Sepehrdost

    2012-04-01

    Full Text Available Introduction & Objective: Hospitals as one of the main institutions providing health care services play an important role in the health system and allocate a high percentage of health sector's budget to them. This study aimed to answer whether social security hospitals efficiency levels are the same for all provinces in Iran? And whether any relationship exists between the human development indexes (HDI of the provinces and technical efficiency levels of the hospitals?Materials & Methods: Data envelopment analysis model has been used to measure technical efficiency of 65 social security hospitals, including small hospitals (working with lower than one hundred active beds and large hospitals (working with over one hundred active beds during the years 2007 to 2009. Further, the relationship between human development index and technical efficiency of hospitals in the provinces has been analyzed.Results: Results show that the average technical efficiency of small and large hospitals working in low and medium HDI provinces (0.912 and 0.937 are more than the average technical efficiency of hospitals in higher HDI provinces (0.870 and 0.887.Conclusion: It is recommended that social security organization concentrated distribute its hospital services in provinces with lower HDI and higher density of population living under the coverage of organization’s insurance. This will eventually puts its positive effects on per capita income of people, as well as more equitable distribution of income. (Sci J Hamadan Univ Med Sci 2012;19(1:32-38

  19. Numerical simulations on efficiency and measurement of capabilities of BGO detectors for high energy gamma ray

    CERN Document Server

    Wen Wan Xin

    2002-01-01

    The energy resolution and time resolution of two phi 75 x 100 BGO detectors for high energy gamma ray newly made were measured with sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co resources. The two characteristic gamma rays of high energy emitted from the thermal neutron capture of germanium in BGO crystal were used for the energy calibration of gamma spectra. The intrinsic photopeak efficiency, single escape probability and double escape probabilities of BGO detectors in photon energy range of 4-30 MeV are numerically calculated with GEANT code. The real count response and count ratio of the uniformly distributed incident photons in energy range of 0-30 MeV are also calculated. The distortion of gamma spectra caused by the photon energy loss extension to lower energy in detection medium is discussed

  20. FastBit: an efficient indexing technology for accelerating data-intensive science

    International Nuclear Information System (INIS)

    Wu Kesheng

    2005-01-01

    FastBit is a software tool for searching large read-only datasets. It organizes user data in a column-oriented structure which is efficient for on-line analytical processing (OLAP), and utilizes compressed bitmap indices to further speed up query processing. Analyses have proven the compressed bitmap index used in FastBit to be theoretically optimal for onedimensional queries. Compared with other optimal indexing methods, bitmap indices are superior because they can be efficiently combined to answer multi-dimensional queries whereas other optimal methods can not. In this paper, we first describe the searching capability of FastBit, then briefly highlight two applications that make extensive use of FastBit, namely Grid Collector and DEX

  1. FastBit: An Efficient Indexing Technology For AcceleratingData-Intensive Science

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kesheng

    2005-06-27

    FastBit is a software tool for searching large read-only data sets. It organizes user data in a column-oriented structure which is efficient for on-line analytical processing (OLAP), and utilizes compressed bitmap indices to further speed up query processing. Analyses have proven the compressed bitmap index used in FastBit to be theoretically optimal for one-dimensional queries. Compared with other optimal indexing methods, bitmap indices are superior because they can be efficiently combined to answer multi-dimensional queries whereas other optimal methods cannot. In this paper, we first describe the searching capability of FastBit, then briefly highlight two applications that make extensive use of FastBit, namely Grid Collector and DEX.

  2. FastBit: an efficient indexing technology for accelerating data-intensive science

    Science.gov (United States)

    Wu, Kesheng

    2005-01-01

    FastBit is a software tool for searching large read-only datasets. It organizes user data in a column-oriented structure which is efficient for on-line analytical processing (OLAP), and utilizes compressed bitmap indices to further speed up query processing. Analyses have proven the compressed bitmap index used in FastBit to be theoretically optimal for onedimensional queries. Compared with other optimal indexing methods, bitmap indices are superior because they can be efficiently combined to answer multi-dimensional queries whereas other optimal methods can not. In this paper, we first describe the searching capability of FastBit, then briefly highlight two applications that make extensive use of FastBit, namely Grid Collector and DEX.

  3. Standardization of electron-capture and complex beta-gamma radionuclides by the efficiency extrapolation method

    International Nuclear Information System (INIS)

    Grigorescu, L.

    1976-07-01

    The efficiency extrapolation method was improved by establishing ''linearity conditions'' for the discrimination on the gamma channel of the coincidence equipment. These conditions were proved to eliminate the systematic error of the method. A control procedure for the fulfilment of linearity conditions and estimation of residual systematic error was given. For law-energy gamma transitions an ''equivalent scheme principle'' was established, which allow for a correct application of the method. Solutions of Cs-134, Co-57, Ba-133 and Zn-65 were standardized with an ''effective standard deviation'' of 0.3-0.7 per cent. For Zn-65 ''special linearity conditions'' were applied. (author)

  4. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  5. SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Y [East Carolina Univ, Greenville, NC (United States); Huang, Z [East Carolina University, Greenville, NC (United States); Lo, S [Case Western Reserve University, Cleveland, OH (United States); Mayr, N; Yuh, W [University of Washington, Seattle, WA (United States)

    2015-06-15

    Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling, automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain

  6. SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

    International Nuclear Information System (INIS)

    Feng, Y; Huang, Z; Lo, S; Mayr, N; Yuh, W

    2015-01-01

    Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling, automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain

  7. Development of the fast and efficient gamma detector using Cherenkov light for TOF-PET

    Science.gov (United States)

    Canot, C.; Alokhina, M.; Abbon, P.; Bard, J. P.; Tauzin, G.; Yvon, D.; Sharyy, V.

    2017-12-01

    In this paper we present two configurations of innovative gamma detectors using Cherenkov light for time-of-flight—Positron Emission Tomography (PET). The first uses heavy crystals as a Cherenkov radiator to develop a demonstrator for a whole body PET scanner with high detection efficiency. We demonstrated a 30% detection efficiency and a 180 ps (FWHM) time resolution, mainly limited by the time transit spread of the photomultiplier. The second configuration uses an innovative liquid, the TriMethyl Bismuth, to develop a high precision brain-scanning PET device with time-of-flight capability. According to Geant4 simulation, we expect to reach a precision of 150 ps (FWHM) and an efficiency of about 25%.

  8. Selection of methanogenic microbial by gamma irradiation on improvement of unaerobic digestion efficiency on biogas formation

    International Nuclear Information System (INIS)

    M Yazid; Aris Bastianudin

    2011-01-01

    Selection of methanogenic microbial by gamma irradiation as an effort on improvement of efficiency process on biogas formation has been done. The objectives of this research is to obtain the methanogenic microbial isolate with high specific growth constant (μ), there for will be applicable for increasing the efficiency of biogas formation process. The microbial content sludge sample was taken from the digester tank conventional biogas installation located in Marangan village, Bokoharjo, Prambanan, Sleman and the sludge was irradiated using Co-60 gamma irradiator with varied dosage dose of 0-25 KGy. Microbial culture formation is conducted in growing media with 30% liquid rumen content in un-aerobe condition by addition of 80% H2 and 20% CO_2 gas mixture. Analysis of colony growth was performed by observation using long-wave ultraviolet rays (UV rays), while the microbial growth was by spectro-photometric analysis. Determination of gas methane product was done using gas chromatographic method. The result shown that 4 isolated methanogenic microbial (RB10, RB15, RB20 and RB25) that grown on 10-25 kGy gamma irradiation. The identification result shows that isolate RB10 and RB25 are belong to Methanobacterium genus, while isolate RB15 and RB20 are belong to Methanosarcina and Methanospirillum genus respectively. The specific growth constant (μ) values of the 4 bacterial isolates are in the range between 0.022 - 0.031. On the other hand, the efficiency of methane gas production for each isolates is in the range of 53.4%. - 67.6%. It can be concluded that isolate RB25 was the isolate with the highest specific growth constant (μ) value 0.031 and its efficiency of methane gas production was 67.6%. (author)

  9. Detection efficiency for radionuclides decaying by electron capture and gamma-Ray

    International Nuclear Information System (INIS)

    Grau, A.; Fernandez, A.

    1985-01-01

    In this paper, the electron capture partial counting efficiency vs the figure of merit for electron-capture and gamma-ray emitters has been computed. The radionuclides tabulated are 48 c r, 54 M n, 57 C o 56 N i, 72 S e, 73 A s, 85 S r, 88 Z r, 92 N b, 103 P d, 111 l n, 119 S b, 125 I , 139 C e and 152 D y. It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 15 cm 3 . (Author) 17 refs

  10. Finance-economical indexes of efficiency of development of railway transport

    Directory of Open Access Journals (Sweden)

    M. Chekhovska

    2012-12-01

    Full Text Available Because of formation of public joint-stock company of railway transport of the common use, by an author it is suggested to carry out the analysis of efficiency of subsequent development of railway transport, leaning against indexes which represent the finance-economical constituent of results of activity of corporate enterprises.

  11. Efficiency and attenuation correction factors determination in gamma spectrometric assay of bulk samples using self radiation

    International Nuclear Information System (INIS)

    Haddad, Kh.

    2009-02-01

    Gamma spectrometry forms the most important and capable tool for measuring radioactive materials. Determination of the efficiency and attenuation correction factors is the most tedious problem in the gamma spectrometric assay of bulk samples. A new experimental and easy method for these correction factors determination using self radiation was proposed in this work. An experimental study of the correlation between self attenuation correction factor and sample thickness and its practical application was also introduced. The work was performed on NORM and uranyl nitrate bulk sample. The results of proposed methods agreed with those of traditional ones.(author)

  12. Highly accurate determination of relative gamma-ray detection efficiency for Ge detector and its application

    International Nuclear Information System (INIS)

    Miyahara, H.; Mori, C.; Fleming, R.F.; Dewaraja, Y.K.

    1997-01-01

    When quantitative measurements of γ-rays using High-Purity Ge (HPGe) detectors are made for a variety of applications, accurate knowledge of oy-ray detection efficiency is required. The emission rates of γ-rays from sources can be determined quickly in the case that the absolute peak efficiency is calibrated. On the other hand, the relative peak efficiencies can be used for determination of intensity ratios for plural samples and for comparison to the standard source. Thus, both absolute and relative detection efficiencies are important in use of γ-ray detector. The objective of this work is to determine the relative gamma-ray peak detection efficiency for an HPGe detector with the uncertainty approaching 0.1% . We used some nuclides which emit at least two gamma-rays with energies from 700 to 2400 keV for which the relative emission probabilities are known with uncertainties much smaller than 0.1%. The relative peak detection efficiencies were calculated from the measurements of the nuclides, 46 Sc, 48 Sc, 60 Co and 94 Nb, emitting two γ- rays with the emission probabilities of almost unity. It is important that various corrections for the emission probabilities, the cascade summing effect, and the self-absorption are small. A third order polynomial function on both logarithmic scales of energy and efficiency was fitted to the data, and the peak efficiency predicted at certain energy from covariance matrix showed the uncertainty less than 0.5% except for near 700 keV. As an application, the emission probabilities of the 1037.5 and 1212.9 keV γ-rays for 48 Sc were determined using the function of the highly precise relative peak efficiency. Those were 0.9777+0,.00079 and 0.02345+0.00017 for the 1037.5 and 1212.9 keV γ-rays, respectively. The sum of these probabilities is close to unity within the uncertainty which means that the certainties of the results are high and the accuracy has been improved considerably

  13. Maximizing Efficiency and Reducing Robotic Surgery Costs Using the NASA Task Load Index.

    Science.gov (United States)

    Walters, Carrie; Webb, Paula J

    2017-10-01

    Perioperative leaders at our facility were struggling to meet efficiency targets for robotic surgery procedures while also maintaining the satisfaction of the surgical team. We developed a human resources time and motion study tool and used it in conjunction with the NASA Task Load Index to observe and analyze the required workload of personnel assigned to 25 robotic surgery procedures. The time and motion study identified opportunities to enlist the help of nonlicensed support personnel to ensure safe patient care and improve OR efficiency. Using the NASA Task Load Index demonstrated that high temporal, effort, and physical demands existed for personnel assisting with and performing robotic surgery. We believe that this process could be used to develop cost-effective staffing models, resulting in safe and efficient care for all surgical patients. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  14. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

    International Nuclear Information System (INIS)

    Kim, Jung-in; Park, So-Yeon; Kim, Hak Jae; Kim, Jin Ho; Ye, Sung-Joon; Park, Jong Min

    2014-01-01

    To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam. Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman’s rank correlation coefficient (γ). The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8). Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively

  15. Absolute 22Na radioactivity measurement by gamma efficiency variation of 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Hino, Yoshio; Kawada, Yasusi.

    1994-01-01

    The absolute radioactivity of 22 Na was obtained by gamma efficiency variation of 4πβ-γ coincidence method. Some other previous techniques, such as sum peak gate method based on the positron emission rate, relative measurement with calibrated ionization chambers, and gamma spectrometry with a HPGe detector, were also tried to ensure the present result. The results of these methods were in reasonable agreement with the present absolute measurement. The assayed source solution of this experiment was transferred to NBS type ampoules, and sealed ampoules were sent to the SIR (International Reference System) in BIPM, Taiwan and Indonesia for the international comparison. (author)

  16. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    Science.gov (United States)

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Efficiency calibration and measurement of self-absorption correction of environmental gamma spectroscopy of soils samples using Marinelli beaker

    International Nuclear Information System (INIS)

    Abdi, M. R.; Mostajaboddavati, M.; Hassanzadeh, S.; Faghihian, H.; Rezaee, Kh.; Kamali, M.

    2006-01-01

    A nonlinear function in combination with the method of mixing activity calibrated is applied for fitting the experimental peak efficiency of HPGe spectrometers in 59-2614 keV energy range. The preparation of Marinelli beaker standards of mixed gamma and RG-set at secular equilibrium with its daughter radionuclides was studied. Standards were prepared by mixing of known amounts of 13B a, 241 Am, 152 Eu, 207 Bi, 24 Na, Al 2 O 3 powder and soil. The validity of these standards was checked by comparison with certified standard reference material RG-set and IAEA-Soil-6 Self-absorption was measured for the activity calculation of the gamma-ray lines about series of 238 U daughter, 232 Th series, 137 Cs and 40 K in soil samples. Self-absorption in the sample will depend on a number of factor including sample composition, density, sample size and gamma-ray energy. Seven Marinelli beaker standards were prepared in different degrees of compaction with bulk density ( ρ) of 1.000 to 1.600 g cm -3 . The detection efficiency versus density was obtained and the equation of self-absorption correction factors calculated for soil samples

  18. Proton/gamma relative thermoluminescence efficiencies of LiF:Mg,Cu,P+PTFE prepared at ININ and TLD-100H

    International Nuclear Information System (INIS)

    Avila, O.; Gonzalez, P.; Murillo, G.

    2009-10-01

    Properties of LiF:Mg,Cu,P+PTFE dosemeters developed at ININ have been investigated in order to evaluate their performance compared to those of equivalent commercial dosemeters. In this work both LiF:Mg,Cu,P+PTFE and TLD-100H pellets were exposed to low fluence 3 MeV protons and to low dose gamma radiation to evaluate experimental proton/gamma efficiencies. Gamma irradiation was performed using the Vic krad irradiator at ININ at varying doses between 25 and 500 mGy. For proton irradiation the Tandem Van de Graaff accelerator at ININ was used. Dosemeters were placed on a holder inside a scattering chamber where protons impinge on a gold target and scatter in all directions. The holder allows for several angular positions so that dosemeters receive proton fluence between 10 6 and 10 1 0 p/cm 2 . Experimental efficiency values found for LiF:Mg,Cu,P+PTFE and TLD-100H were 0.18 +- 03 and 0.23 +- 0.03, respectively. These results allow to confirm the reliability of the dosemeters developed at ININ. (Author)

  19. Efficiency evaluation of customer satisfaction index in e-banking using the fuzzy data envelopment analysis

    Directory of Open Access Journals (Sweden)

    Aliyar Esmaeili

    2014-01-01

    Full Text Available E-commerce has created significant opportunities for the corporations to understand the customers’ expectations, desired values, to increase their satisfaction and to expand their market share, more efficiently. The most significant activity of e-commerce is in the field of e-banking and financial services. Customer satisfaction index is a concept introduced for evaluating of the service quality in electronic banking. Considering the relative importance of customer satisfaction in e-banking, defining scientific criteria for the assessment of mentioned index is very important. So, a scientific and efficient method is always needed. The purpose of this paper is to use the fuzzy data envelopment analysis (DEA techniques for evaluating and ranking the efficiency of online customer satisfaction index in eight economic banks in Iran. Here, we first study the fuzzy set theory and the method of traditional DEA in the same model. Next, the relationship between them were developed, which provide the fuzzy DEA model with qualitative data. The SPSS and GAMS software package were employed to analyze the data collected through questionnaires. The results show that three economic banks in terms of customer satisfaction in e-banking were located on the efficiency border and were quite efficient.

  20. Theoretical determination of gamma spectrometry systems efficiency based on probability functions. Application to self-attenuation correction factors

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, Manuel, E-mail: manuel.barrera@uca.es [Escuela Superior de Ingeniería, University of Cadiz, Avda, Universidad de Cadiz 10, 11519 Puerto Real, Cadiz (Spain); Suarez-Llorens, Alfonso [Facultad de Ciencias, University of Cadiz, Avda, Rep. Saharaui s/n, 11510 Puerto Real, Cadiz (Spain); Casas-Ruiz, Melquiades; Alonso, José J.; Vidal, Juan [CEIMAR, University of Cadiz, Avda, Rep. Saharaui s/n, 11510 Puerto Real, Cádiz (Spain)

    2017-05-11

    A generic theoretical methodology for the calculation of the efficiency of gamma spectrometry systems is introduced in this work. The procedure is valid for any type of source and detector and can be applied to determine the full energy peak and the total efficiency of any source-detector system. The methodology is based on the idea of underlying probability of detection, which describes the physical model for the detection of the gamma radiation at the particular studied situation. This probability depends explicitly on the direction of the gamma radiation, allowing the use of this dependence the development of more realistic and complex models than the traditional models based on the point source integration. The probability function that has to be employed in practice must reproduce the relevant characteristics of the detection process occurring at the particular studied situation. Once the probability is defined, the efficiency calculations can be performed in general by using numerical methods. Monte Carlo integration procedure is especially useful to perform the calculations when complex probability functions are used. The methodology can be used for the direct determination of the efficiency and also for the calculation of corrections that require this determination of the efficiency, as it is the case of coincidence summing, geometric or self-attenuation corrections. In particular, we have applied the procedure to obtain some of the classical self-attenuation correction factors usually employed to correct for the sample attenuation of cylindrical geometry sources. The methodology clarifies the theoretical basis and approximations associated to each factor, by making explicit the probability which is generally hidden and implicit to each model. It has been shown that most of these self-attenuation correction factors can be derived by using a common underlying probability, having this probability a growing level of complexity as it reproduces more precisely

  1. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  2. Measurements of the light conversion efficiency of lithium borate for alpha particles relative to cobalt-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D.T.; Wall, B.F.; Fisher, E.S. (National Radiological Protection Board, Harwell (UK))

    1982-01-01

    The results are reported of measurements of the light conversion efficiencies of lithium borate TLD phosphor of British Nuclear Fuels Ltd. manufacture to 5.65 MeV and 2.4 MeV alpha particles relative to /sup 60/Co gamma radiation.

  3. Natural background gamma-ray spectrum. List of gamma-rays ordered in energy from natural radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Ichimiya, Tsutomu [Japan Radioisotope Association, Tokyo (Japan); Narita, Tsutomu; Kitao, Kensuke

    1998-03-01

    A quick index to {gamma}-rays and X-rays from natural radionuclides is presented. In the list, {gamma}-rays are arranged in order of increasing energy. The list also contains {gamma}-rays from radioactive nuclides produced in a germanium detector and its surrounding materials by interaction with cosmic neutrons, as well as direct {gamma}-rays from interaction with the neutrons. Artificial radioactive nuclides emitting {gamma}-rays with same or near energy value as that of the natural {gamma}-rays and X-rays are also listed. In appendix, {gamma}-ray spectra from a rock, uranium ore, thorium, monazite and uraninite and also background spectra obtained with germanium detectors placed in iron or lead shield have been given. The list is designed for use in {gamma}-ray spectroscopy under the conditions of highly natural background, such as in-situ environmental radiation monitoring or low-level activity measurements, with a germanium detector. (author)

  4. Comparative studies on PADC polymeric detector treated by gamma radiation and Ar ion beam

    International Nuclear Information System (INIS)

    El-Saftawy, A.A.; Abdel Reheem, A.M.; Kandil, S.A.; Abd El Aal, S.A.; Salama, S.

    2016-01-01

    Highlights: • The induced defects on PADC polymer by low energy Ar ions bombardments have been investigated and evaluated with respect to gamma rays. • Low energy ions in the range of 3 keV is not examined elsewhere. And offers a competitive irradiation tool to gamma. • The structure, hardness and wear resistance enhanced after irradiation. • The optical properties changed, the optical band gap decreased and the refractive index enhanced. • The used ion source proves efficiency in improving surface properties of PADC polymer in comparison to the obtained results by the powerful energy source, gamma rays. - Abstract: In the present study, a comparative analysis and evaluation of the induced defects in polyallyl diglycol carbonate (PADC) polymeric detector exposed to Ar+ and gamma radiation were made. To get insight into the structure defects due to irradiation, X-ray diffraction (XRD) technique was employed. The PADC surface structure changed after irradiation due to the reduction in the surface crystalline structure and the formation of disordered systems. Also, surface morphology changes were traced using scanning electron microscopy (SEM) and showed minor surface irregularities after gamma irradiation and large changes upon Ar+ irradiation. Additionally, micro-hardness and friction coefficient of the irradiated samples were investigated and found to increase after irradiation. UV–vis spectroscopy was used to estimate the optical band gap energy which considered as the basis for calculating the number of conjugated carbon atoms responsible for the blackening effect and color changes took place over the PADC surface. It was found that as the applied dose increased, the band gap decreased and the number of carbon clusters get larger. The refractive index and the dispersion parameters for the studied polymer were calculated and discussed. Also, the induced defects on the polymer surface which serve as a non-radiative centers resulting in reduced

  5. Comparative studies on PADC polymeric detector treated by gamma radiation and Ar ion beam

    Energy Technology Data Exchange (ETDEWEB)

    El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Abdel Reheem, A.M. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Kandil, S.A. [Cyclotron project, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Abd El Aal, S.A. [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Salama, S. [Radiation Protection & Civil Defense Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt)

    2016-05-15

    Highlights: • The induced defects on PADC polymer by low energy Ar ions bombardments have been investigated and evaluated with respect to gamma rays. • Low energy ions in the range of 3 keV is not examined elsewhere. And offers a competitive irradiation tool to gamma. • The structure, hardness and wear resistance enhanced after irradiation. • The optical properties changed, the optical band gap decreased and the refractive index enhanced. • The used ion source proves efficiency in improving surface properties of PADC polymer in comparison to the obtained results by the powerful energy source, gamma rays. - Abstract: In the present study, a comparative analysis and evaluation of the induced defects in polyallyl diglycol carbonate (PADC) polymeric detector exposed to Ar+ and gamma radiation were made. To get insight into the structure defects due to irradiation, X-ray diffraction (XRD) technique was employed. The PADC surface structure changed after irradiation due to the reduction in the surface crystalline structure and the formation of disordered systems. Also, surface morphology changes were traced using scanning electron microscopy (SEM) and showed minor surface irregularities after gamma irradiation and large changes upon Ar+ irradiation. Additionally, micro-hardness and friction coefficient of the irradiated samples were investigated and found to increase after irradiation. UV–vis spectroscopy was used to estimate the optical band gap energy which considered as the basis for calculating the number of conjugated carbon atoms responsible for the blackening effect and color changes took place over the PADC surface. It was found that as the applied dose increased, the band gap decreased and the number of carbon clusters get larger. The refractive index and the dispersion parameters for the studied polymer were calculated and discussed. Also, the induced defects on the polymer surface which serve as a non-radiative centers resulting in reduced

  6. A Spatiotemporal Indexing Approach for Efficient Processing of Big Array-Based Climate Data with MapReduce

    Science.gov (United States)

    Li, Zhenlong; Hu, Fei; Schnase, John L.; Duffy, Daniel Q.; Lee, Tsengdar; Bowen, Michael K.; Yang, Chaowei

    2016-01-01

    Climate observations and model simulations are producing vast amounts of array-based spatiotemporal data. Efficient processing of these data is essential for assessing global challenges such as climate change, natural disasters, and diseases. This is challenging not only because of the large data volume, but also because of the intrinsic high-dimensional nature of geoscience data. To tackle this challenge, we propose a spatiotemporal indexing approach to efficiently manage and process big climate data with MapReduce in a highly scalable environment. Using this approach, big climate data are directly stored in a Hadoop Distributed File System in its original, native file format. A spatiotemporal index is built to bridge the logical array-based data model and the physical data layout, which enables fast data retrieval when performing spatiotemporal queries. Based on the index, a data-partitioning algorithm is applied to enable MapReduce to achieve high data locality, as well as balancing the workload. The proposed indexing approach is evaluated using the National Aeronautics and Space Administration (NASA) Modern-Era Retrospective Analysis for Research and Applications (MERRA) climate reanalysis dataset. The experimental results show that the index can significantly accelerate querying and processing (10 speedup compared to the baseline test using the same computing cluster), while keeping the index-to-data ratio small (0.0328). The applicability of the indexing approach is demonstrated by a climate anomaly detection deployed on a NASA Hadoop cluster. This approach is also able to support efficient processing of general array-based spatiotemporal data in various geoscience domains without special configuration on a Hadoop cluster.

  7. Query and Update Efficient B+-Tree Based Indexing of Moving Objects

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lin, Dan; Ooi, Beng Chin

    2004-01-01

    . This motivates the design of a solution that enables the B+-tree to manage moving objects. We represent moving-object locations as vectors that are timestamped based on their update time. By applying a novel linearization technique to these values, it is possible to index the resulting values using a single B...... are streamed to a database. Indexes for moving objects must support queries efficiently, but must also support frequent updates. Indexes based on minimum bounding regions (MBRs) such as the R-tree exhibit high concurrency overheads during node splitting, and each individual update is known to be quite costly......+-tree that partitions values according to their timestamp and otherwise preserves spatial proximity. We develop algorithms for range and k nearest neighbor queries, as well as continuous queries. The proposal can be grafted into existing database systems cost effectively. An extensive experimental study explores...

  8. Provincial human development index, a guide for efficiency level analysis: the case of iran.

    Science.gov (United States)

    Sabermahani, Asma; Barouni, Mohsen; Seyedin, Hesam; Aryankhesal, Aidin

    2013-01-01

    Human Development Index (HDI) is a composite indicator that can show the impact of economic strategies on human life standards. The index is calculated by three main factors of income, education and health. This research studies the status of HDI across the Iranian provinces, its changes over time and the efficiency of provinces in using resources. The data for 2001 and 2009 was obtained from the Iranian Center of Statistics. Data envelopment analysis technique was used to analyze the data. To calculate the efficiency, Banker, Charnes and Cooper's model was used. The national mean for the HDI in 2001 was 0.717 while it grew to 0.747 in 2009. Except for one province, all others had an improved human development index. Low ranked provinces such as Sistan & Baluchistan and Kurdistan stayed at the bottom in 2009 as well. Some provinces such as Bushehr with developing oil industries, or those purposively benefited from national oil income showed good growth. In some provinces, such as Hormozgan, out-migration of manpower to its neighboring province, Bushehr, was associated with decrease of the provincial income level. The number of efficient provinces increased from 5 to 13 in 2009. Iran falls among countries with high human development index based on the 2009 data. However, the distribution of HDI status across provinces was highly varied and the difference between high- and low-developed provinces increased in 2009. The government needs to revise policies concerning distribution of resources among the provinces.

  9. The efficiency of gamma irradiation on the bacterium pseudomonas fluorescence (Migh) against the mediterranean fruit fly ceratitis capitata (wiedemann)

    International Nuclear Information System (INIS)

    Fadel, A.M.

    2002-01-01

    The efficiency of the bacterium pseudomonas fluorescence against the mediterranean fruit fly ceratitis capitata (Wied.) was investigated. Adult emergence was significantly reduced by applying the wild and gamma irradiated strain (150 and 300 Gy). The highest reduction occurred by the mutant P1 and the highest concentration (10 8 ). The activity of this bacteria increased by gamma irradiation compared to that of the wild isolate. The reduction in adult survival of both males and females was highly significant by applying the irradiated bacteria with the two doses of gamma radiation and different concentration (10 8 , 10 6 and 10 4 ) of bacterial suspension. Applying the bacteria as a culture filtrate reduced adult survival of wild strain significantly, while the irradiated strain recorded a significant reduction in males and females with the highest concentration (100 %) and by applying the two doses of gamma radiation (150 and 300 Gy) and in females only at the concentration 50% by using the dose of 150 Gy

  10. EFFECT OF GAMMA RADIATION OF MACRO MUTATIONS, EFFECTIVENESS AND EFFICIENCY UNDER M2 GENERATION IN PEA (Pisum sativum L.

    Directory of Open Access Journals (Sweden)

    Arvind KUMAR

    2016-06-01

    Full Text Available The present investigation was undertaken to study the spectrum of macro mutants, effectiveness and efficiency of different doses of gamma rays in pea variety (Arkel. The seeds were treated with gamma rays viz., 00kR (dry control, 05kR, 10kR, 15kR, 20kR, 25kR, 30kR, 35kR, 40kR (dry seeds and presoaked seeds of the same was exposed to 00kR (wet control, 05kR, 10kR, 15kR, 20kR (kilo Roentgen biological damage was calculated in M1 and M2 generation based on lethality (L and pollen sterility. The irradiated seeds were sown in the M1 field their respective controls and harvested in bulk to raise the M2 generation in Randomized Block Design (RBD with three replications. The spectrum of macro mutants i.e., plant stature (tall, dwarf, small dwarf, maturity (early, late, pod shape (bold, long, short, seed colour (brown, light white, light green and seed shape (small, bold, wrinkled were observed in M2 generation. The usefulness of any mutagen in plant breeding depends not only on its effectiveness but also upon if efficiency. Mutagenic effectiveness is a measure of the frequency of mutations induced by unit mutagen dose, whereas mutagenic efficiency is measure of proportion of mutations in relation of undesirable changes like lethality and sterility are used for gamma rays. A result of the indicated positive relationship in M2 generation with macro mutation, effectiveness and efficiency was found to be highest at lowest doses.

  11. Policy efficiency in the field of food sustainability. The adjusted food agriculture and nutrition index.

    Science.gov (United States)

    Agovino, Massimiliano; Cerciello, Massimiliano; Gatto, Andrea

    2018-07-15

    This work introduces a revised version of the Food Sustainability Index, proposed by the Economist Intelligence Unit and the Barilla Center for Food and Nutrition in 2016. Our Adjusted Food Sustainability Index features two important advantages: 1) it employs the Mazziotta-Pareto method to compute weights, hence granting an objective aggregation criterion and 2) it does not take policy variables into account, thus focusing on the status quo. The policy variables are aggregated into the Policy Index, measuring the quality of the food sustainability policies. We compute the two indices for 25 countries worldwide, then we use the Data Envelopment Analysis to evaluate policy efficiency. Our results show that country-level variation in policy efficiency is wide and policies affect food sustainability significantly, especially when they target nutritional challenges. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Mean of the typical decoding rates: a new translation efficiency index based on the analysis of ribosome profiling data.

    Science.gov (United States)

    Dana, Alexandra; Tuller, Tamir

    2014-12-01

    Gene translation modeling and prediction is a fundamental problem that has numerous biomedical implementations. In this work we present a novel, user-friendly tool/index for calculating the mean of the typical decoding rates that enables predicting translation elongation efficiency of protein coding genes for different tissue types, developmental stages, and experimental conditions. The suggested translation efficiency index is based on the analysis of the organism's ribosome profiling data. This index could be used for example to predict changes in translation elongation efficiency of lowly expressed genes that usually have relatively low and/or biased ribosomal densities and protein levels measurements, or can be used for example for predicting translation efficiency of new genetically engineered genes. We demonstrate the usability of this index via the analysis of six organisms in different tissues and developmental stages. Distributable cross platform application and guideline are available for download at: http://www.cs.tau.ac.il/~tamirtul/MTDR/MTDR_Install.html. Copyright © 2015 Dana and Tuller.

  13. GammaWorkshops Proceedings

    International Nuclear Information System (INIS)

    Ramebaeck, H.; Straelberg, E.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.

    2012-01-01

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  14. GammaWorkshops Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H. (ed.) (Swedish Defence Research Agency (Sweden)); Straalberg, E. (Institute for Energy Technology, Kjeller (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority, STUK (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (Iceland))

    2012-01-15

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  15. Numerical Simulations of Pillar Structured Solid State Thermal Neutron Detector Efficiency and Gamma Discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Conway, A; Wang, T; Deo, N; Cheung, C; Nikolic, R

    2008-06-24

    This work reports numerical simulations of a novel three-dimensionally integrated, {sup 10}boron ({sup 10}B) and silicon p+, intrinsic, n+ (PIN) diode micropillar array for thermal neutron detection. The inter-digitated device structure has a high probability of interaction between the Si PIN pillars and the charged particles (alpha and {sup 7}Li) created from the neutron - {sup 10}B reaction. In this work, the effect of both the 3-D geometry (including pillar diameter, separation and height) and energy loss mechanisms are investigated via simulations to predict the neutron detection efficiency and gamma discrimination of this structure. The simulation results are demonstrated to compare well with the measurement results. This indicates that upon scaling the pillar height, a high efficiency thermal neutron detector is possible.

  16. Neutron detection gamma ray sensitivity criteria

    International Nuclear Information System (INIS)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Mace, Emily K.; Stephens, Daniel L.; Woodring, Mitchell L.

    2011-01-01

    The shortage of 3 He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9 3 He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

  17. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples

    International Nuclear Information System (INIS)

    Baccouche, S.; Al-Azmi, D.; Karunakara, N.; Trabelsi, A.

    2012-01-01

    Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. Two scintillation detectors were studied in this work; CsI(Tl) and NaI(Tl) with identical size for measurement of terrestrial samples for performance study. This work describes a Monte Carlo method for making the full-energy efficiency calibration curves for both detectors using gamma-ray energies associated with the decay of naturally occurring radionuclides 137 Cs (661 keV), 40 K (1460 keV), 238 U ( 214 Bi, 1764 keV) and 232 Th ( 208 Tl, 2614 keV), which are found in terrestrial samples. The magnitude of the coincidence summing effect occurring for the 2614 keV emission of 208 Tl is assessed by simulation. The method provides an efficient tool to make the full-energy efficiency calibration curve for scintillation detectors for any samples geometry and volume in order to determine accurate activity concentrations in terrestrial samples. - Highlights: ► CsI (Tl) and NaI (Tl) detectors were studied for the measurement of terrestrial samples. ► Monte Carlo method was used for efficiency calibration using natural gamma emitting terrestrial radionuclides. ► The coincidence summing effect occurring for the 2614 keV emission of 208 Tl is assessed by simulation.

  18. Counting efficiency for radionuclides decaying by beta and gamma-ray emission; Calculo de la eficiencia de recuento de nucleidos que experimentan desintegracion beta y desexcitacion gamma simple

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A.; Garcia-Torano, E.

    1988-07-01

    In this paper, counting efficiency vs figure of merit for beta and gamma-ray emitters has been computed. It is assumed that the decay scheme has only a gamma level and the beta-ray emission may be coincident with the gamma-rays or the internal-conversion electrons. The radionuclides tabulated are: 20 {sub 0}, 20{sub p}, 28{sub A}l, 35{sub p}, 41{sub A}r, 42{sub K}, 47{sub S}e, 62{sub F}e, 66{sub C}u, 81{sub G}e, 86{sub B}b, 108{sub R}u, 112{sub p}d, 121{sub S}n(Ni), 122{sub I}n, 129{sub I}, 141{sub C}e 171{sub T}m, 194{sub O}s, 2O3{sub H}g, 205{sub H}g, 210{sub p}b, 225{sub R}a, 142{sub p}r, 151{sub S}m, 244{sub A}m(m). It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 10 cm''3. (Author) 8 refs.

  19. The efficiency calibration and development of environmental correction factors for an in situ high-resolution gamma spectroscopy well logging system

    International Nuclear Information System (INIS)

    Giles, J.R.

    1996-05-01

    A Gamma Spectroscopy Logging System (GSLS) has been developed to study sub-surface radionuclide contamination. Absolute efficiency calibration of the GSLS was performed using simple cylindrical borehole geometry. The calibration source incorporated naturally occurring radioactive material (NORM) that emitted photons ranging from 186-keV to 2,614-keV. More complex borehole geometries were modeled using commercially available shielding software. A linear relationship was found between increasing source thickness and relative photon fluence rates at the detector. Examination of varying porosity and moisture content showed that as porosity increases, relative photon fluence rates increase linearly for all energies. Attenuation effects due to iron, water, PVC, and concrete cylindrical shields were found to agree with previous studies. Regression analyses produced energy-dependent equations for efficiency corrections applicable to spectral gamma-ray well logs collected under non-standard borehole conditions

  20. An efficient modularized sample-based method to estimate the first-order Sobol' index

    International Nuclear Information System (INIS)

    Li, Chenzhao; Mahadevan, Sankaran

    2016-01-01

    Sobol' index is a prominent methodology in global sensitivity analysis. This paper aims to directly estimate the Sobol' index based only on available input–output samples, even if the underlying model is unavailable. For this purpose, a new method to calculate the first-order Sobol' index is proposed. The innovation is that the conditional variance and mean in the formula of the first-order index are calculated at an unknown but existing location of model inputs, instead of an explicit user-defined location. The proposed method is modularized in two aspects: 1) index calculations for different model inputs are separate and use the same set of samples; and 2) model input sampling, model evaluation, and index calculation are separate. Due to this modularization, the proposed method is capable to compute the first-order index if only input–output samples are available but the underlying model is unavailable, and its computational cost is not proportional to the dimension of the model inputs. In addition, the proposed method can also estimate the first-order index with correlated model inputs. Considering that the first-order index is a desired metric to rank model inputs but current methods can only handle independent model inputs, the proposed method contributes to fill this gap. - Highlights: • An efficient method to estimate the first-order Sobol' index. • Estimate the index from input–output samples directly. • Computational cost is not proportional to the number of model inputs. • Handle both uncorrelated and correlated model inputs.

  1. Gamma Spectroscopy with Pixellated CdZnTe Gamma Detectors

    International Nuclear Information System (INIS)

    Shor, A.; Mardor, I.; Eisen, Y.

    2002-01-01

    Pixellated CdZnTe detectors are good candidates for room temperature gamma detection requiring spectroscopic performance with imaging capabilities. The CdZnTe materials possess high resistivity and good electron charge transport properties. The poor charge transport for the holes inherent in the CdZnTe material can be circumvented by fabricating the electrodes in any one of a number of structures designed for unipolar charge detection[1]. Recent interest in efficient gamma detection at relatively higher gamma energies has imposed more stringent demands on the CdZnTe material and on detector design and optimization. We developed at Soreq a technique where signals from all pixels and from the common electrode are processed, and then a correction is applied for improving the energy resolution and the photopeak efficiency. For illumination with an un-collimated 133 Ba source , we obtain a combined detector energy resolution of 5.0 % FWHM for the 81 keV peak, and 1.5 % FWHM for the 356 keV peak. We discuss the importance of detector material with high electron (μτ) e for thick Pixellated detectors

  2. The no-arbitrage efficiency test of the OMX Index option market

    DEFF Research Database (Denmark)

    Hou, Ai Jun; Wiktorsson, Magnus; Zhao, RuiZhi

    2012-01-01

    In this paper, we test the market efficiency of the OMXS30 Index option market. The market efficiency definition is the absence of arbitrage oppor- tunity in the market. We first check the arbitrage opportunity by examining the boundary conditions and the Put-Call-Parity that must be satisfied...... in the market. Then a variance based efficiency test is performed by establish- ing a risk neutral portfolio and re-balance the initial portfolio in different trading strategies. In order to choose the most appropriate model for option price and hedging strategies, we calibrate several most applied models, i.......e. the BS, Merton, Heston, Bates model and Affine Jump Diffusion models. Our results indicate that the AJD model significantly outperforms other models in the option price forecast and the trading strategies. The bound- ary and the PCP test and the dynamic hedging strategy results evidence...

  3. Formulation of the relationship between indices of neutron-gamma and gamma-gamma method and the percentrage of iron

    International Nuclear Information System (INIS)

    Majorowicz, J.

    1973-01-01

    In this article, the author presents the possibility of a complex utilization of radiometric logging methods, neutron-gamma profiling and gamma-gamma density logging for determining percentage of iron and establishing geophysical possibilities of identifying zones of economically profitable ores in borehole profiles. Figures present the correlations between indices of neutron-gamma and gamma-gamma logging methods and the percentage of iron, as well as the correlation of neutron-gamma and gamma-gamma indices for zones minerallized with iron ores. The article presents the correlational analyses of the results: the correlational coefficients are given as well as total error in determining iron content on the basis of each of the methods described. Next, a multidimensional statistical analysis is carried out on the results obtained. On the basis of the two-dimensional correlational coefficients calculated and the average standard deviation, an equation of linear regression was formulated, simultaneously involving three parameters - the indices of neutron-gamma and gamma-gamma logging and the percentage of iron. The multiple correlational coefficient obtained markedly exceeds the two-dimentional correlation coefficient (r=0.974>rsub(xz)>rsub(yz)>rsub(xy)). The given method of utilizing multidimensional statistics in borehole geophysics for identifying iron ores is an efficient one. On the basis of several relationships among independent variables which are less obvious (smaller values of correlational coefficient), it is possible to obtain a single distinct relationship involving all variables simultaneously. (author)

  4. Effect of Gamma Radiation on Nutritional Indices of Larval and Adults Stages of Tribolium castaneum (Coleoptera: Tenebrionidae)

    International Nuclear Information System (INIS)

    Ahmadi, M.; Moharramipour, S.

    2012-01-01

    In this study antifeedant effect of different doses of gamma radiation as a controlling safe method on flour weevil, Tribolium castaneum (Herbst) larvae and adult was studied. Doses of 100, 400, 600, 800 and 1000 Gy of gamma radiation were used and after 72 hours, nutritional indices were evaluated. The relative growth rate, relative consumption rate, efficiency of conversion of ingested food and feeding deterrence index as nutritional indices were evaluated. Treatments were assessed by flour wheat disc at 27±1 d egree C and 65 p ercent h umidity in a dark condition. The results showed that the relative growth rate of flour weevil larvae and adults decreased significantly (P<0.05) by gamma radiation and the severity of this reduction in larvae was higher than the adults. Although the relative growth rates decreased in adults, this rate in doses of 400, 600, 800 and 1000 Gy showed no significant difference. The relative food consumption rate also decreased with the gamma radiation and its value found to be inversely proportional to the dose radiation. Our experiments showed that the use of gamma radiation exposure to 800 Gy had no significant effect on the efficiency of conversion of ingested food of larvae and reduction was observed only when the gamma radiation was used in 1000 Gy. The feeding deterrence effect of gamma radiation, especially on the larvae was high but no significant difference between doses of 100 to 800 Gy was observed. The results showed that gamma radiation that induces antifeedant effect can be applied as an effective method in control of T. castaneum.

  5. Effect of gamma radiation on ''in vitro''' efficiency of fungicides

    International Nuclear Information System (INIS)

    Menten, J.O.M.; Oliveira, G.C.X.

    1984-01-01

    The activity of 60 Co gamma radiation on eight fungicides used in post-harvesting treatment of agricultural products, was studied. Rhizoctonia solani was used in biological test as indicator-fungus. The fungicides were submitted to gamma radiation doses of O (control), 1, 10, 100, 1000 and 10.000 kR, samples of the fungicides were added to the PSA culture media to obtain 0, 1, 10 and 100 ppm concentrations of the active component of each product and of each radiation dose. The ED 50 (concentration of fungicide necessary to cause 50% radial reduction of the fungic mycelium) of each fungicide in the different gamma radiation doses was determined. (M.A.C.) [pt

  6. A simple and reliable method to detect gamma irradiated lentil (Lens culinaris Medik.) seeds by germination efficiency and seedling growth test

    International Nuclear Information System (INIS)

    Chaudhuri, Sadhan K.

    2002-01-01

    Germination efficiency and root/shoot length of germinated seedling is proposed to identify irradiated lentil seeds. Germination percentage was reduced above 0.2 kGy and lentil seeds were unable to germinate above 1.0 kGy dose. The critical dose that prevented the root elongation varied from 0.1 to 0.5 kGy. The sensitivity of lentil seeds to gamma irradiation was inversely proportional to moisture content of the seeds. Radiation effects could be detected in seeds even 12 months storage after gamma irradiation

  7. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples

    Energy Technology Data Exchange (ETDEWEB)

    Baccouche, S., E-mail: souad.baccouche@cnstn.rnrt.tn [UR-MDTN, National Center for Nuclear Sciences and Technology, Technopole Sidi Thabet, 2020 Sidi Thabet (Tunisia); Al-Azmi, D., E-mail: ds.alazmi@paaet.edu.kw [Department of Applied Sciences, College of Technological Studies, Public Authority for Applied Education and Training, Shuwaikh, P.O. Box 42325, Code 70654 (Kuwait); Karunakara, N., E-mail: karunakara_n@yahoo.com [University Science Instrumentation Centre, Mangalore University, Mangalagangotri 574199 (India); Trabelsi, A., E-mail: adel.trabelsi@fst.rnu.tn [UR-MDTN, National Center for Nuclear Sciences and Technology, Technopole Sidi Thabet, 2020 Sidi Thabet (Tunisia); UR-UPNHE, Faculty of Sciences of Tunis, El-Manar University, 2092 Tunis (Tunisia)

    2012-01-15

    Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. Two scintillation detectors were studied in this work; CsI(Tl) and NaI(Tl) with identical size for measurement of terrestrial samples for performance study. This work describes a Monte Carlo method for making the full-energy efficiency calibration curves for both detectors using gamma-ray energies associated with the decay of naturally occurring radionuclides {sup 137}Cs (661 keV), {sup 40}K (1460 keV), {sup 238}U ({sup 214}Bi, 1764 keV) and {sup 232}Th ({sup 208}Tl, 2614 keV), which are found in terrestrial samples. The magnitude of the coincidence summing effect occurring for the 2614 keV emission of {sup 208}Tl is assessed by simulation. The method provides an efficient tool to make the full-energy efficiency calibration curve for scintillation detectors for any samples geometry and volume in order to determine accurate activity concentrations in terrestrial samples. - Highlights: Black-Right-Pointing-Pointer CsI (Tl) and NaI (Tl) detectors were studied for the measurement of terrestrial samples. Black-Right-Pointing-Pointer Monte Carlo method was used for efficiency calibration using natural gamma emitting terrestrial radionuclides. Black-Right-Pointing-Pointer The coincidence summing effect occurring for the 2614 keV emission of {sup 208}Tl is assessed by simulation.

  8. A Moving-Object Index for Efficient Query Processing with PeerWise Location Privacy

    DEFF Research Database (Denmark)

    Lin, Dan; Jensen, Christian S.; Zhang, Rui

    2011-01-01

    attention has been paid to enabling so-called peer-wise privacy—the protection of a user’s location from unauthorized peer users. This paper identifies an important efficiency problem in existing peer-privacy approaches that simply apply a filtering step to identify users that are located in a query range......, but that do not want to disclose their location to the querying peer. To solve this problem, we propose a novel, privacy-policy enabled index called the PEB-tree that seamlessly integrates location proximity and policy compatibility. We propose efficient algorithms that use the PEB-tree for processing privacy......-aware range and kNN queries. Extensive experiments suggest that the PEB-tree enables efficient query processing....

  9. The ratio of nurse consultation and physician efficiency index of senior rheumatologists is significantly higher than junior physicians in rheumatology residency training

    DEFF Research Database (Denmark)

    Emamifar, Amir; van Bui Hansen, Morten Hai; Jensen Hansen, Inger Marie

    2017-01-01

    To elucidate the difference between ratios of nurse consultation sought by senior rheumatologists and junior physicians in rheumatology residency training, and also to evaluate physician efficiency index respecting patients with rheumatoid arthritis (RA). Data regarding outpatient visits for RA...... patients between November 2013 and 2015 were extracted. The mean interval (day) between consultations, the nurse/physician visits ratio, and physician efficiency index (nurse/physician visits ratio × mean interval) for each senior and junior physicians were calculated. Disease Activity Score in 28 joints....../physician visits ratio (P = .01) and mean efficiency index (P = .04) of senior rheumatologists were significantly higher than that of junior physicians. Regression analysis showed a positive correlation between physician postgraduate experience and physician efficiency index adjusted for DAS28 at baseline...

  10. Efficiency of pre-sowing gamma-irradiation of tomato seeds under conditions of protected ground and under the effect of mineral fertilizers

    International Nuclear Information System (INIS)

    Pogosyan, G.S.; Avakyan, A.G.; Semerdzhyan, S.P.

    1983-01-01

    Efficiency of pre-sowing gamma-irradiation of seeds on yield capacity and other practical and biological criteria of hothouse fertilized tomatoes has been studied. It is shown that pre-sowing gamma-irradiation of seeds increases the output of early production and total crop. It is suggested to use in production the irradiation of seeds in the dose of 12 Gr cultivating tomatoes on the background of N 240 P 240 K 240 and in the dose of 5 Gr on the ground of N 120 P 120 K 120 fertilizers

  11. Efficiency versus Maqashid Sharia Index: an Application on Indonesian Islamic Bank

    Directory of Open Access Journals (Sweden)

    Aam S. Rusydiana

    2017-09-01

    Full Text Available The Development of Islamic Banking Industry in Indonesia relatively shows a good tendency. In the market, inefficiency would be the great obstacles in head to head to conventional bank. Despite of efficiency performance in Islamic Bank, Islamic Bank also must have sharia compliance performance. So it needed to identified the efficiency of Islamic Bank in Indonesia and the achievement of Maslahah in term of three aspects, there are education, the creating of justice, and the attainment of welfare. This study would try to measure the efficiency of Islamic Banking Industry with Data Envelopment Analysis (DEA method and also to evaluate the performance by using Maqasid Sharia Index (MSI. Banxia Frontier Analyst 3.1 used in the data calculation. The calculation of the level of Islamic Bank efficiency in this study are relative, not absolute. Result of this study indicate four main findings, first, Islamic bank involve in quadran 1 is Islamic bank who reached the highest efficiency and the best performance; there are BMI and Bank Panin Sharia. Islamic bank involve in quadran 2 is Islamic bank who reached the highest efficiency and the lowest performance, there are BSM, Maybank Sharia, and Bank Sharia Bukopin. Islamic bank involve in quadran 3 is Islamic bank who reached the lowest efficiency and have a good performance, there are BRI sharia, and BCA sharia. Islamic bank involve in quadran 4 is Islamic bank who reached the lowest efficiency and the lowest performance, there are Bank Mega Sharia, Victoria Sharia, BNI Sharia, and BJB Sharia.

  12. Stochastic modeling of soundtrack for efficient segmentation and indexing of video

    Science.gov (United States)

    Naphade, Milind R.; Huang, Thomas S.

    1999-12-01

    Tools for efficient and intelligent management of digital content are essential for digital video data management. An extremely challenging research area in this context is that of multimedia analysis and understanding. The capabilities of audio analysis in particular for video data management are yet to be fully exploited. We present a novel scheme for indexing and segmentation of video by analyzing the audio track. This analysis is then applied to the segmentation and indexing of movies. We build models for some interesting events in the motion picture soundtrack. The models built include music, human speech and silence. We propose the use of hidden Markov models to model the dynamics of the soundtrack and detect audio-events. Using these models we segment and index the soundtrack. A practical problem in motion picture soundtracks is that the audio in the track is of a composite nature. This corresponds to the mixing of sounds from different sources. Speech in foreground and music in background are common examples. The coexistence of multiple individual audio sources forces us to model such events explicitly. Experiments reveal that explicit modeling gives better result than modeling individual audio events separately.

  13. Efficient approximations of dispersion relations in optical waveguides with varying refractive-index profiles.

    Science.gov (United States)

    Li, Yutian; Zhu, Jianxin

    2015-05-04

    In this paper we consider the problem of computing the eigen-modes for the varying refractive-index profile in an open waveguide. We first approximate the refractive-index by a piecewise polynomial of degree two, and the corresponding Sturm-Liouville problem (eigenvalue problem) of the Helmholtz operator in each layer can be solved analytically by the Kummer functions. Then, analytical approximate dispersion equations are established for both TE and TM cases. Furthermore, the approximate dispersion equations converge fast to the exact ones for the continuous refractive-index function as the maximum value of the subinterval sizes tends to zero. Suitable numerical methods, such as Müller's method or the chord secant method, may be applied to the dispersion relations to compute the eigenmodes. Numerical simulations show that our method is very practical and efficient for computing eigenmodes.

  14. Possible galactic origin of. gamma. -ray bursts

    Energy Technology Data Exchange (ETDEWEB)

    Manchanda, R K; Ramsden, D [Southampton Univ. (UK). Dept. of Physics

    1977-03-31

    It is stated that extragalactic models for the origin of non-solar ..gamma..-ray bursts include supernova bursts in remote galaxies, and the collapse of the cores of active stars, whilst galactic models are based on flare stars, thermonuclear explosions in neutron stars and the sudden accretion of cometary gas on to neutron stars. The acceptability of any of these models may be tested by the observed size spectrum of the ..gamma..-ray bursts. The extragalactic models predict a power law spectrum with number index -1.5, whilst for the galactic models the number index will be -1. Experimental data on ..gamma..-ray bursts is, however, still meagre, and so far only 44 confirmed events have been recorded by satellite-borne instruments. The number spectrum of the observed ..gamma..-ray bursts indicates that the observed distribution for events with an energy < 10/sup -4/ erg/cm/sup 2/ is flat; this makes the choice of any model completely arbitrary. An analysis of the observed ..gamma..-ray events is here presented that suggests very interesting possibilities for their origin. There appears to be a preferred mean energy for ..gamma..-ray bursts; some 90% of the recorded events show a mean energy between 5 x 10/sup -5/ and 5 x 10/sup -4/ erg/cm/sup 2/, contrary to the predicted characteristics of the number spectrum of various models. A remarkable similarity is found between the distribution of ..gamma..-ray bursts and that of supernova remnants, suggesting a genetic relationship between the two and the galactic origin of the ..gamma..-ray bursts, and the burst source could be identified with completely run down neutron stars, formed during supernova explosions.

  15. Gamma--gamma directional correlations and coincidence studies in /sup 154/Gd

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, J B; Gupta, S L; Hamilton, J H; Ramayya, A V [Vanderbilt Univ., Nashville, Tenn. (USA). Dept. of Physics; Delhi Univ. (India). Ramjas Coll.)

    1977-06-01

    The intensities, placements and E2/M1 mixing ratios of transitions in the decay of /sup 154/Eu have been carefully studied to provide accurate data for microscopic calculations. Coincidence relationships in thhe decay of /sup 154/Eu have been studied extensively with a multiparameter ..gamma..-..gamma.. coincidence system with two large volume Ge(Li) detectors. Spectra in coincidence with twenty energy gates were analyzed. Twenty-nine new coincidence relationships were established and confirmed most, but not all, of several levels previously assigned by energy fits only. From an analysis of coincidence spectra and singles spectra with a 18% efficiency Ge(Li) detector new information on the gamma-ray intensities were obtained. Precise values of the E2/M1 mixing ratios of transitions from the gamma- and beta-vibrational bands to the g.s. band have been determined from ..gamma..-..gamma.. directional correlation measurements with a NaI(Tl)-Ge(Li) detector coincidence system. Mixing ratios were obtained for a number of other transitions including those from KPI = 0/sup -/ and 2+ bands from direct and skipped cascade correlations.

  16. Photopeak efficiency response function of an underwater gamma-ray NaI(Tl) detector using MCNP-X

    International Nuclear Information System (INIS)

    Salgado, William L.; Silva, Ademir X.; Salgado, Cesar M.

    2015-01-01

    This work presents a study to calculate the response function of a 1.5″ x 1″ NaI(Tl) scintillation detector when it is used in the marine environment in the energy range from 20 keV to 662 keV. The method takes into account both the scattering of photons in the water and the detection mechanism of the detector. In addition, the calculation of the response function of the whole system is essential for suppressing the background of the measurement and for estimating the concentration of the involved radionuclides, especially given the greater probability of primary gamma photons undergoing multiple scattering events before they interact with the detector. The experimental photopeak efficiency measurements for point sources were compared with the simulated results under the same conditions of the experimental setup to validate the simulation of the detector. Monte Carlo simulations were performed using the MCNP-X code for the investigation of gamma-ray absorption in water in different brines. The energy resolution curve was used to improve the response of the mathematical simulation of the detector. The detector’s simulation was based on information obtained from the gammagraphy technique. Both dimensions and materials were used for the calculation with the MCNP-X code. The photopeak efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment with different salinities was calculated. (author)

  17. On the sum of Gamma-Gamma variates with application to the fast outage probability evaluation over fading channels

    KAUST Repository

    Ben Issaid, Chaouki

    2017-04-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of independent and identically distributed Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  18. On the sum of Gamma-Gamma variates with application to the fast outage probability evaluation over fading channels

    KAUST Repository

    Ben Issaid, Chaouki; Rached, Nadhir B.; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2017-01-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of independent and identically distributed Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  19. Detection of gamma-neutron radiation by solid-state scintillation detectors. Detection of gamma-neutron radiation by novel solid-state scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhikov, V.; Grinyov, B.; Piven, L.; Onyshchenko, G.; Sidletskiy, O. [Institute for Scintillation Materials of the NAS of Ukraine, Kharkov, (Ukraine); Naydenov, S. [Institute for Single Crystals of the National Academy of Sciences of Ukraine, Kharkov, (Ukraine); Pochet, T. [DETEC-Europe, Vannes (France); Smith, C. [Naval Postgraduate School, Monterey, CA (United States)

    2015-07-01

    It is known that solid-state scintillators can be used for detection of both gamma radiation and neutron flux. In the past, neutron detection efficiencies of such solid-state scintillators did not exceed 5-7%. At the same time it is known that the detection efficiency of the gamma-neutron radiation characteristic of nuclear fissionable materials is by an order of magnitude higher than the efficiency of detection of neutron fluxes alone. Thus, an important objective is the creation of detection systems that are both highly efficient in gamma-neutron detection and also capable of exhibiting high gamma suppression for use in the role of detection of neutron radiation. In this work, we present the results of our experimental and theoretical studies on the detection efficiency of fast neutrons from a {sup 239}Pu-Be source by the heavy oxide scintillators BGO, GSO, CWO and ZWO, as well as ZnSe(Te, O). The most probable mechanism of fast neutron interaction with nuclei of heavy oxide scintillators is the inelastic scattering (n, n'γ) reaction. In our work, fast neutron detection efficiencies were determined by the method of internal counting of gamma-quanta that emerge in the scintillator from (n, n''γ) reactions on scintillator nuclei with the resulting gamma energies of ∼20-300 keV. The measured efficiency of neutron detection for the scintillation crystals we considered was ∼40-50 %. The present work included a detailed analysis of detection efficiency as a function of detector and area of the working surface, as well as a search for new ways to create larger-sized detectors of lower cost. As a result of our studies, we have found an unusual dependence of fast neutron detection efficiency upon thickness of the oxide scintillators. An explanation for this anomaly may involve the competition of two factors that accompany inelastic scattering on the heavy atomic nuclei. The transformation of the energy spectrum of neutrons involved in the (n, n

  20. Collimatorless imaging of gamma rays with help of gamma-ray tracking

    CERN Document Server

    Marel, J V D

    2001-01-01

    In many gamma-ray detector systems that are built for imaging purposes Compton scattered photons are suppressed as much as possible. However, the information from photons that scattered inside a detector system can be used to reconstruct the tracks of the photons with help of gamma-ray tracking. Estimates of the incident directions of the photons can be made and an image can be created. Examples of potential applications for this technique are the use as a gamma-camera in medical imaging (e.g. SPECT) or as a detector for PET. Due to the omission of collimators, much higher detection efficiencies can be achieved, reducing the doses required for an image. A gamma-ray tracking method, called backtracking, has been developed for nuclear spectroscopy. The method tracks gamma-rays originating from a point source in the center of a spherical detector system consisting of position-sensitive germanium detectors. This method can also be used as a tracking technique for imaging of an unknown source distribution. With he...

  1. Researches with the 'Fertexpert' model concerning the relationships between the efficiency indexes of the fertilizers usage in optimal economic rates and the agrochemical indexes of the soil and expected yields

    International Nuclear Information System (INIS)

    Budoi, G.; Berca, M.; Borlan, Z.; Gavriluta, I.; Soare, M.; Danuso, F.; Bireescu, L.

    1999-01-01

    The 'Fertexpert' model allows undertaking researches concerning the variation of efficiency indexes for fertilizers usage in the case of many crops depending on the content of available soil nutrients (the values of soil agrochemical indexes - IA) and on the expected yield, R s , when fertilization are applied in optimal economic rates, DOE. The physical efficiency indexes calculated and researched are the following: the total physical yield increase, SFR (kg/ha), the specific average yield increase, SSp (kg/kg N, P 2 O 5 or K 2 O), the specific consumption of active substance (a.s.) from fertilizer, CSp (kg a.s./1 kg average yield increase). The economic efficiency indexes computed are: the total profit, in monetary units/ha, the specific profit, in monetary units/l monetary unit spent with fertilization, PSp, and in monetary units/kg a.s., PSpsa. The model also allows the study of DOE variation depending on R s and IA. Starting from the made calculations, there can be drown up specific graphics that can then be used in practice and for research purposes to. Refs. 6 (author)

  2. Thermal neutron capture gamma-rays

    International Nuclear Information System (INIS)

    Tuli, J.K.

    1983-01-01

    The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,α), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,#betta#) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide

  3. a Novel Approach of Indexing and Retrieving Spatial Polygons for Efficient Spatial Region Queries

    Science.gov (United States)

    Zhao, J. H.; Wang, X. Z.; Wang, F. Y.; Shen, Z. H.; Zhou, Y. C.; Wang, Y. L.

    2017-10-01

    Spatial region queries are more and more widely used in web-based applications. Mechanisms to provide efficient query processing over geospatial data are essential. However, due to the massive geospatial data volume, heavy geometric computation, and high access concurrency, it is difficult to get response in real time. Spatial indexes are usually used in this situation. In this paper, based on k-d tree, we introduce a distributed KD-Tree (DKD-Tree) suitbable for polygon data, and a two-step query algorithm. The spatial index construction is recursive and iterative, and the query is an in memory process. Both the index and query methods can be processed in parallel, and are implemented based on HDFS, Spark and Redis. Experiments on a large volume of Remote Sensing images metadata have been carried out, and the advantages of our method are investigated by comparing with spatial region queries executed on PostgreSQL and PostGIS. Results show that our approach not only greatly improves the efficiency of spatial region query, but also has good scalability, Moreover, the two-step spatial range query algorithm can also save cluster resources to support a large number of concurrent queries. Therefore, this method is very useful when building large geographic information systems.

  4. A NOVEL APPROACH OF INDEXING AND RETRIEVING SPATIAL POLYGONS FOR EFFICIENT SPATIAL REGION QUERIES

    Directory of Open Access Journals (Sweden)

    J. H. Zhao

    2017-10-01

    Full Text Available Spatial region queries are more and more widely used in web-based applications. Mechanisms to provide efficient query processing over geospatial data are essential. However, due to the massive geospatial data volume, heavy geometric computation, and high access concurrency, it is difficult to get response in real time. Spatial indexes are usually used in this situation. In this paper, based on k-d tree, we introduce a distributed KD-Tree (DKD-Tree suitbable for polygon data, and a two-step query algorithm. The spatial index construction is recursive and iterative, and the query is an in memory process. Both the index and query methods can be processed in parallel, and are implemented based on HDFS, Spark and Redis. Experiments on a large volume of Remote Sensing images metadata have been carried out, and the advantages of our method are investigated by comparing with spatial region queries executed on PostgreSQL and PostGIS. Results show that our approach not only greatly improves the efficiency of spatial region query, but also has good scalability, Moreover, the two-step spatial range query algorithm can also save cluster resources to support a large number of concurrent queries. Therefore, this method is very useful when building large geographic information systems.

  5. Efficiency limit of solar cells with index-near-zero photon management layers

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, A.P.

    2017-05-15

    As single-junction solar cells saturate in efficiency, the topic of photon management has generated interest in the long running quest to exceed the Shockley-Queisser efficiency limit. While a mirror applied to the backside of a solar cell has proven its benefit as a photon management layer in record setting devices that fall within the Shockley-Queisser limit, it has been proposed that a new type of photon management layer – a transparent index-near-zero (INZ) material – applied to the top surface of a solar cell will allow it to finally exceed the Shockley-Queisser limit. INZ layers – and their influence on solar cell current density, open circuit voltage, and power conversion efficiency – are analyzed. By considering the principle of detailed balance, Snell's law, and the role that entropy plays, it is shown that INZ layers do not allow a solar cell to exceed the Shockley-Queisser efficiency limit. At best, a solar cell with an INZ layer would have the same Shockley-Queisser limiting efficiency as a conventional solar cell tracked under a direct solar spectrum (direct beam radiation only), yet would suffer diminished efficiency under a global solar spectrum (direct beam plus diffuse light) due to the presence of an external critical acceptance angle.

  6. Efficiency limit of solar cells with index-near-zero photon management layers

    International Nuclear Information System (INIS)

    Kirk, A.P.

    2017-01-01

    As single-junction solar cells saturate in efficiency, the topic of photon management has generated interest in the long running quest to exceed the Shockley-Queisser efficiency limit. While a mirror applied to the backside of a solar cell has proven its benefit as a photon management layer in record setting devices that fall within the Shockley-Queisser limit, it has been proposed that a new type of photon management layer – a transparent index-near-zero (INZ) material – applied to the top surface of a solar cell will allow it to finally exceed the Shockley-Queisser limit. INZ layers – and their influence on solar cell current density, open circuit voltage, and power conversion efficiency – are analyzed. By considering the principle of detailed balance, Snell's law, and the role that entropy plays, it is shown that INZ layers do not allow a solar cell to exceed the Shockley-Queisser efficiency limit. At best, a solar cell with an INZ layer would have the same Shockley-Queisser limiting efficiency as a conventional solar cell tracked under a direct solar spectrum (direct beam radiation only), yet would suffer diminished efficiency under a global solar spectrum (direct beam plus diffuse light) due to the presence of an external critical acceptance angle.

  7. Efficiency limit of solar cells with index-near-zero photon management layers

    Science.gov (United States)

    Kirk, A. P.

    2017-05-01

    As single-junction solar cells saturate in efficiency, the topic of photon management has generated interest in the long running quest to exceed the Shockley-Queisser efficiency limit. While a mirror applied to the backside of a solar cell has proven its benefit as a photon management layer in record setting devices that fall within the Shockley-Queisser limit, it has been proposed that a new type of photon management layer - a transparent index-near-zero (INZ) material - applied to the top surface of a solar cell will allow it to finally exceed the Shockley-Queisser limit. INZ layers - and their influence on solar cell current density, open circuit voltage, and power conversion efficiency - are analyzed. By considering the principle of detailed balance, Snell's law, and the role that entropy plays, it is shown that INZ layers do not allow a solar cell to exceed the Shockley-Queisser efficiency limit. At best, a solar cell with an INZ layer would have the same Shockley-Queisser limiting efficiency as a conventional solar cell tracked under a direct solar spectrum (direct beam radiation only), yet would suffer diminished efficiency under a global solar spectrum (direct beam plus diffuse light) due to the presence of an external critical acceptance angle.

  8. Application of gamma-gamma logging in predicting anomalous geodynamic phenomena in hard coal mines

    International Nuclear Information System (INIS)

    Blaha, F.; Keclik, L.

    1980-01-01

    The application is discussed of gamma-gamma logging in the prediction of dynamic events like coal and gas bursts, coal sliding in medium dip seams and rock bumps. The overall analysis of the applied rock characterization method and of the measurement results shows that the prediction possibilities of dynamic events are partly limited due to specific effects of the rock massive. In these cases, however, unambiguous results may be obtained by other geophysical methods such as seismoacoustic testing etc. In most cases, however, the gamma-gamma logging results may be used for estimating the degree of dynamic events or checking the efficiency of preventive measures in the locality under investigation. (author)

  9. On the Efficient Market Hypothesis of Stock Market Indexes: The Role of Non-synchronous Trading and Portfolio Effects

    OpenAIRE

    Ortiz, Roberto; Contreras, Mauricio; Villena, Marcelo

    2015-01-01

    In this article, the long-term behavior of the stock market index of the New York Stock Exchange is studied, for the period 1950 to 2013. Specifically, the CRSP Value-Weighted and CRSP Equal-Weighted index are analyzed in terms of market efficiency, using the standard ratio variance test, considering over 1600 one week rolling windows. For the equally weighted index, the null hypothesis of random walk is rejected in the whole period, while for the weighted market value index, the null hypothe...

  10. Studies on safety and efficiency of gamma-irradiated ginseng

    International Nuclear Information System (INIS)

    Kwon, Joong Ho; Cho, Han Ok; Byun, Myung Wo; Kim, Suc Won; Yang, Jae Seong; Yoo, Young Soo; Jin, Joon Ha; Park, Soon Chul

    1991-09-01

    Gamma irradiation was applied to the biological quality improvement and preservation of white ginseng which has problems in a hygienic quality and storage stability. The current phosphine treatment showed no influence on microorganisms contaminated even though it was very useful for disinfestation of the sample, while 5 kGy irradiation effectively controlled the biological quality of the stored sample, with minimal effects on the quality parameters of white ginseng. Thus, it is concluded that gamma irradiation at a range of 5 kGy can be an alternative method of chemical fumigants provided air-tight packaging excluding recontamination is used for the stored product. (Author)

  11. Myasthenia Gravis Impairment Index: Responsiveness, meaningful change, and relative efficiency.

    Science.gov (United States)

    Barnett, Carolina; Bril, Vera; Kapral, Moira; Kulkarni, Abhaya V; Davis, Aileen M

    2017-12-05

    To study responsiveness and meaningful change of the Myasthenia Gravis Impairment Index (MGII) and its relative efficiency compared to other measures. We enrolled 95 patients receiving prednisone, IV immunoglobulin (IVIg), or plasma exchange (PLEX) and 54 controls. Patients were assessed with the MGII and other measures-including the Quantitative Myasthenia Gravis Score, Myasthenia Gravis Composite, and Myasthenia Gravis Activities of Daily Living-at baseline and 3-4 weeks after treatment. Statistical markers of responsiveness included between-groups and within-group differences, and we estimated the relative efficiency of the MGII compared to other measures. Patient-meaningful change was assessed with an anchor-based method, using the patient's impression of change. We determined the minimal detectable change (MDC) and the minimal important difference (MID) at the group and individual level. Treated patients had a higher change in MGII scores than controls (analysis of covariance p 1 favoring the MGII. The MGII demonstrated responsiveness to prednisone, IVIg, and PLEX in patients with myasthenia. There is a differential response in ocular and generalized symptoms to type of therapy. The MGII has higher relative efficiency than comparison measures and is viable for use in clinical trials. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  12. INDEXING AND INDEX FUNDS

    Directory of Open Access Journals (Sweden)

    HAKAN SARITAŞ

    2013-06-01

    Full Text Available Proponents of the efficient market hypothesis believe that active portfolio management is largely wasted effort and unlikely to justify the expenses incurred. Therefore, they advocate a passive investment strategy that makes no attempt to outsmart the market. One common strategy for passive management is indexing where a fund is designed to replicate the performance of a broad-based index of stocks and bonds. Traditionally, indexing was used by institutional investors, but today, the use of index funds proliferated among individual investors. Over the years, both international and domestic index funds have disproportionately outperformed the market more than the actively managed funds have.

  13. The German 2020 Energy Turnaround Index featuring a special focus on economic efficiency; Energiewende-Index Deutschland 2020. Fokusthema Wirtschaftlichkeit

    Energy Technology Data Exchange (ETDEWEB)

    Vahlenkamp, Thomas [McKinsey and Company, Duesseldorf (Germany); Gohl, Matthias [McKinsey and Company, Berlin (Germany)

    2012-12-15

    The decision to raise the levy imposed by the Renewable Energies Law has kindled the discussion as to how the energy turnaround can best be implemented and made affordable in the first place. The search for solutions should be founded on as full a picture of the situation as possible as well as a fact base shared by all. The aspiration and purpose of the German 2020 Energy Turnaround Index created by McKinsey and Company is to create precisely such a fact base. Every 3 months the index gives an update on the status of the energy turnaround based on 15 indicators. The present update additionally takes a closer look at the aspect of economic efficiency, which together with climate and environment protection and security of supply forms the triad of imperatives driving the energy turnaround.

  14. Laser Compton Scattering Gamma Ray Induced Photo-Trasmutation

    CERN Document Server

    Li, Dazhi

    2004-01-01

    High brightness beams of gamma rays produced with laser Compton scattering have the potential to realize photo-transmutation through (γ,n) reaction, implying an efficient method to dispose long-lived fission products. Preliminary investigations have been carried out in understanding the feasibility of development of a transmutation facility to repose nuclear waste. A laser Compton scattering experimental setup based on a storage ring started to generate gamma-ray beams for studying the coupling of gamma photons and nuclear giant resonance. This paper demonstrates the dependency of nuclear transmutation efficiency on target dimensions and gamma ray features. 197Au sample was adopted in our experiment, and experimental results correspond to the theoretical estimations.

  15. Efficiency factor of a chemical nuclear reactor with gamma sources

    International Nuclear Information System (INIS)

    Anguis T, C.

    1975-01-01

    A chemonuclear reactor is simulated in order to calculate the efficiency factor of molecular species in chemical reactions induced by gamma radiation, with the purpose to obtain information for its design and consider the electromagnetic energy as a possible solution to the present problem of energy. The research is based on a mathematical model of succesive Compton processes applied to spherical and cylindrical geometry and corroborated through the absorbed dose and the experimental date of the increase factor, for the radioisotopic sources Co-60 and Cs-137 relating the quantity of energy deposited into various cylinders with the G value, the relation radius/height of the reactor is optimized according to the molecular production. This is illustrated with the radiolysis of a solution of CH 3 OH/H 2 O which forms H 2 and with the obtainment of C 2 H 5 Br that represents and industrial process induced radioactively. The results show a greater energy deposition with Cs-137 but a larger production of H 2 /hr with Co-60, and besides we can find high production values of C 2 H 5 Br. The cylinder with more advantages is that whose relation R/H is of 0.5. It can be concluded that the final selection of the reactor should be made after a more intense study of the used isotope and the source activity. The efficiency factor of H 2 can be increased selecting the appropriate type and concentration of solute of the irradiated aqueous solutions

  16. Canonical correlation between the gamma and X-ray data of Swift GRBs

    International Nuclear Information System (INIS)

    Balazs, L. G.; Horvath, I.; Meszaros, P.; Tusnady, G.; Veres, P.

    2009-01-01

    We used the canonical correlation analysis of the multivariate statistics to study the interrelation between the gamma (Fluence, 1 sec Peakflux, duration) and X-ray (early X flux, 24 hours X flux, X decay index, X spectral index, X HI column density) data. We computed the canonical correlations and variables showing that there is a significant interrelation between the gamma and X-ray data. Using the canonical variables resulted in the analysis we computed their correlations (canonical loadings) with the original ones. The canonical loadings revealed that the gamma-ray fluence and the early X-ray flux give the strongest contribution to the correlation in contrast to the X-ray decay index and spectral index. An interesting new result appears to be the strong contribution of the HI column density to the correlation. Accepting the collapsar model of long GRBs this effect may be interpreted as an indication for the ejection of an HI envelope by the progenitor in the course of producing the GRB.

  17. Management Index Systems and Energy Efficiency Diagnosis Model for Power Plant: Cases in China

    Directory of Open Access Journals (Sweden)

    Jing-Min Wang

    2016-01-01

    Full Text Available In recent years, the energy efficiency of thermal power plant largely contributes to that of the industry. A thorough understanding of influencing factors, as well as the establishment of scientific and comprehensive diagnosis model, plays a key role in the operational efficiency and competitiveness for the thermal power plant. Referring to domestic and abroad researches towards energy efficiency management, based on Cloud model and data envelopment analysis (DEA model, a qualitative and quantitative index system and a comprehensive diagnostic model (CDM are construed. To testify rationality and usability of CDM, case studies of large-scaled Chinese thermal power plants have been conducted. In this case, CDM excavates such qualitative factors as technology, management, and so forth. The results shows that, compared with conventional model, which only considered production running parameters, the CDM bears better adaption to reality. It can provide entities with efficient instruments for energy efficiency diagnosis.

  18. Evaluation of efficiency of a semiconductor gamma camera

    CERN Document Server

    Otake, H; Takeuchi, Y

    2002-01-01

    We evaluation basic characteristics of a compact type semiconductor gamma camera (eZ-SCOPE AN) of Cadmium Zinc Telluride (CdZnTe). This new compact gamma camera has 256 semiconductors representing the same number of pixels. Each semiconductor is 2 mm square and is located in 16 lines and rows on the surface of the detector. The specific performance characteristics were evaluated in the study referring to National Electrical Manufactures Association (NEMA) standards; intrinsic energy resolution, intrinsic count rate performance, integral uniformity, system planar sensitivity, system spatial resolution, and noise to the neighboring pixels. The intrinsic energy resolution measured 5.7% as full width half maximum (FWHM). The intrinsic count rate performance ranging from 17 kcps to 1,285 kcps was evaluated, but the highest intrinsic count rate was not observed. Twenty percents count loss was recognized at 1,021 kcps. The integral uniformity was 1.3% with high sensitivity collimator. The system planar sensitivity w...

  19. Gamma spectrometry of infinite 4Π geometry

    International Nuclear Information System (INIS)

    Nordemann, D.J.R.

    1987-07-01

    Owing to the weak absorption og gamma radiation by matter, gamma-ray spectrometry may be applied to samples of great volume. A very interesting case is that of the gamma-ray spectrometry applied with 4Π geometry around the detector on a sample assumed to be of infinite extension. The determination of suitable efficiencies allows this method to be quantitative. (author) [pt

  20. Towards Efficient Positional Inverted Index

    Directory of Open Access Journals (Sweden)

    Petr Procházka

    2017-02-01

    Full Text Available We address the problem of positional indexing in the natural language domain. The positional inverted index contains the information of the word positions. Thus, it is able to recover the original text file, which implies that it is not necessary to store the original file. Our Positional Inverted Self-Index (PISI stores the word position gaps encoded by variable byte code. Inverted lists of single terms are combined into one inverted list that represents the backbone of the text file since it stores the sequence of the indexed words of the original file. The inverted list is synchronized with a presentation layer that stores separators, stop words, as well as variants of the indexed words. The Huffman coding is used to encode the presentation layer. The space complexity of the PISI inverted list is O ( ( N − n ⌈ log 2 b N ⌉ + ( ⌊ N − n α ⌋ + n × ( ⌈ log 2 b n ⌉ + 1 where N is a number of stems, n is a number of unique stems, α is a step/period of the back pointers in the inverted list and b is the size of the word of computer memory given in bits. The space complexity of the presentation layer is O ( − ∑ i = 1 N ⌈ log 2 p i n ( i ⌉ − ∑ j = 1 N ′ ⌈ log 2 p j ′ ⌉ + N with respect to p i n ( i as a probability of a stem variant at position i, p j ′ as the probability of separator or stop word at position j and N ′ as the number of separators and stop words.

  1. Increased brain uptake of gamma-aminobutyric acid in a rabbit model of hepatic encephalopathy

    International Nuclear Information System (INIS)

    Bassett, M.L.; Mullen, K.D.; Scholz, B.; Fenstermacher, J.D.; Jones, E.A.

    1990-01-01

    Transfer of the inhibitory neurotransmitter gamma-aminobutyric acid across the normal blood-brain barrier is minimal. One prerequisite for gamma-aminobutyric acid in plasma contributing to the neural inhibition of hepatic encephalopathy would be that increased transfer of gamma-aminobutyric acid across the blood-brain barrier occurs in liver failure. The aim of the present study was to determine if brain gamma-aminobutyric acid uptake is increased in rabbits with stage II-III (precoma) hepatic encephalopathy due to galactosamine-induced fulminant hepatic failure. A modification of the Oldendorf intracarotid artery-injection technique was applied. [3H] gamma-aminobutyric acid, [14C] butanol, and 113mIn-labeled serum protein (transferrin) were injected simultaneously 4 s before decapitation. The ipsilateral brain uptake index of gamma-aminobutyric acid was determined from measurements of the 3 isotopes in 5 brain regions. Uncorrected or simple brain uptake indices of [3H] gamma-aminobutyric acid and [113mIn] transferrin were calculated using [14C] butanol as the highly extracted reference compound. The [113mIn] transferrin data were also used to correct the brain uptake index of [3H] gamma-aminobutyric acid for intravascular retention of [3H] gamma-aminobutyric acid. The methodology adopted minimized problems attributable to rapid [3H] gamma-aminobutyric acid metabolism, and slow brain washout and recirculation of the radiolabeled tracers. Both the uncorrected and corrected brain uptake indices of gamma-aminobutyric acid as well as the simple brain uptake index of transferrin were significantly increased in both stage II and III hepatic encephalopathy in all brain regions studied. Moreover, these brain uptake indices were significantly greater in stage III hepatic encephalopathy than in stage II hepatic encephalopathy

  2. GammaWorkshops Proceedings

    DEFF Research Database (Denmark)

    Strålberg, Elisabeth; Klemola, Seppo; Nielsen, Sven Poul

    to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical...

  3. Measurement and decomposition of energy efficiency of Northeast China-based on super efficiency DEA model and Malmquist index.

    Science.gov (United States)

    Ma, Xiaojun; Liu, Yan; Wei, Xiaoxue; Li, Yifan; Zheng, Mengchen; Li, Yudong; Cheng, Chaochao; Wu, Yumei; Liu, Zhaonan; Yu, Yuanbo

    2017-08-01

    Nowadays, environment problem has become the international hot issue. Experts and scholars pay more and more attention to the energy efficiency. Unlike most studies, which analyze the changes of TFEE in inter-provincial or regional cities, TFEE is calculated with the ratio of target energy value and actual energy input based on data in cities of prefecture levels, which would be more accurate. Many researches regard TFP as TFEE to do analysis from the provincial perspective. This paper is intended to calculate more reliably by super efficiency DEA, observe the changes of TFEE, and analyze its relation with TFP, and it proves that TFP is not equal to TFEE. Additionally, the internal influences of the TFEE are obtained via the Malmquist index decomposition. The external influences of the TFFE are analyzed afterward based on the Tobit models. Analysis results demonstrate that Heilongjiang has the highest TFEE followed by Jilin, and Liaoning has the lowest TFEE. Eventually, some policy suggestions are proposed for the influences of energy efficiency and study results.

  4. Extragalactic Gamma-Ray Astrophysics

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    During the last decades, various classes of radio-loud active galactic nuclei have been established as sources of high-energy radiation extending over a very broad range from soft gamma-rays (photon energies E~MeV) up to very-high-energy gamma-rays (E>100 GeV). These include blazars of different types, as well as young and evolved radio galaxies. The observed gamma-ray emission from such implies efficient particle acceleration processes taking place in highly magnetized and relativistic jets produced by supermassive black holes, processes that have yet to be identified and properly understood. In addition, nearby starforming and starburst galaxies, some of which host radio-quiet Seyfert-type nuclei, have been detected in the gamma-ray range as well. In their cases, the observed gamma-ray emission is due to non-thermal activity in the interstellar medium, possibly including also a contribution from accretion disks and nuclear outflows. Finally, the high-energy emission from clusters of galaxies remains elusive...

  5. Effect of water stress on total biomass, tuber yield, harvest index and water use efficiency in Jerusalem artichoke

    Science.gov (United States)

    The objectives of this study were to determine the effect of drought on tuber yield, total biomass, harvest index, water use efficiency of tuber yield (WUEt) and water use efficiency of biomass (WUEb), and to evaluate the differential responses of Jerusalem artichoke (JA) varieties under drought str...

  6. Gamma histograms for radiotherapy plan evaluation

    International Nuclear Information System (INIS)

    Spezi, Emiliano; Lewis, D. Geraint

    2006-01-01

    Background and purpose: The technique known as the 'γ evaluation method' incorporates pass-fail criteria for both distance-to-agreement and dose difference analysis of 3D dose distributions and provides a numerical index (γ) as a measure of the agreement between two datasets. As the γ evaluation index is being adopted in more centres as part of treatment plan verification procedures for 2D and 3D dose maps, the development of methods capable of encapsulating the information provided by this technique is recommended. Patients and methods: In this work the concept of γ index was extended to create gamma histograms (GH) in order to provide a measure of the agreement between two datasets in two or three dimensions. Gamma area histogram (GAH) and gamma volume histogram (GVH) graphs were produced using one or more 2D γ maps generated for each slice of the irradiated volume. GHs were calculated for IMRT plans, evaluating the 3D dose distribution from a commercial treatment planning system (TPS) compared to a Monte Carlo (MC) calculation used as reference dataset. Results: The extent of local anatomical inhomogenities in the plans under consideration was strongly correlated with the level of difference between reference and evaluated calculations. GHs provided an immediate visual representation of the proportion of the treated volume that fulfilled the γ criterion and offered a concise method for comparative numerical evaluation of dose distributions. Conclusions: We have introduced the concept of GHs and investigated its applications to the evaluation and verification of IMRT plans. The gamma histogram concept set out in this paper can provide a valuable technique for quantitative comparison of dose distributions and could be applied as a tool for the quality assurance of treatment planning systems

  7. International comparison of interpolation procedures for the efficiency of germanium gamma-ray spectrometers (GAM83 exercise)

    International Nuclear Information System (INIS)

    Zijp, W.L.; Polle, A.N.; Nolthenius, H.J.

    1986-01-01

    Results are presented for the outcome of an international intercomparison of a particular gamma-ray spectrometric procedure. Laboratories were asked to determine full energy peak efficiencies and activities by means of their own procedures, starting from supplied peak-efficiency data. Four data sets for four different conditions of germanium detectors were distributed. The sets comprised: a high accuracy- (uncertainty > 1%) data set with a relatively large number of measured data (SET 1); a low accuracy- (uncertainty 3-5%) data set with a relatively small number of measured data (SET 2); a low energy-data set (SET 3); a high accuracy-data set with a relatively small number of measured data (SET 4). The intercomparison (coded GAM83) was organized and analyzed under auspices of the International Committee for Radionuclide Metrology (ICRM). The results comprise the analysis of the contributions of 41 participants

  8. Low level GAMMA0 spectrometry by beta-gamma coincidence

    International Nuclear Information System (INIS)

    Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    1999-01-01

    Low level gamma spectrometry has a wide application, especially in environmental monitoring. Two variants, based on a beta-gamma coincidence technique, were studied. The equipment was composed of a beta detector and a Ge(Li) gamma detector (6% - relative efficiency), with the associated electronics. The gamma rays are recorded by the multichannel analyzer (4096 channels) only if the associated beta particles, which precede the gamma transitions, are registered in coincidence. Two types of beta detectors were used: plastic and liquid scintillators. In both cases, an external lead shield of 5 cm thick was used. The integral gamma background (50-1700 KeV) was reduced about 85 and 50 times, respectively. The corresponding MDA (Minimum Detectable Activity) values decreased about 1.5 and (3-7) times, respectively. The 2π sr plastic beta detector was placed on top the Ge(Li). The sample was inserted between the two detectors. The measurement time was 10 4 s. A 4π sr detector, built of the same material, was also studied, but it proved to be less advantageous because the background was reduced only 16 times; for a MDA reduction similar with that of the 2π sr variant, a longer measurement was needed (3.10 4 s). The other type of beta detector used, was a liquid scintillator. The dissolving of the samples in scintillator ensures a 4π sr measurement geometry. The vials with scintillator (10 ml volume) were placed on top the Ge(Li) and visualised by the photocathode of a phototube. This setup was surrounded by an enclosure which prevent the light penetration. The measurement time was 10 4 s. The only difficulty encountered in this low level measurement method is the accurate determination of the beta efficiency. A limitation is the possibility to measure only small mass samples. These variants are more simple and cheaper than others, previously studied. The advantage of the method is obvious when, instead of low MDA values, shorter measurement times are preferred. The

  9. Sampling Polya-Gamma random variates: alternate and approximate techniques

    OpenAIRE

    Windle, Jesse; Polson, Nicholas G.; Scott, James G.

    2014-01-01

    Efficiently sampling from the P\\'olya-Gamma distribution, ${PG}(b,z)$, is an essential element of P\\'olya-Gamma data augmentation. Polson et. al (2013) show how to efficiently sample from the ${PG}(1,z)$ distribution. We build two new samplers that offer improved performance when sampling from the ${PG}(b,z)$ distribution and $b$ is not unity.

  10. GammaSem Proceedings - A Nordic seminar for users of gamma spectrometry

    International Nuclear Information System (INIS)

    Nunez, P.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.; Israelson, C.

    2010-03-01

    The project GammaSem was proposed to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and to establish a network of users of gamma spectrometry in the Nordic countries, thereby strengthening the collaboration and improving all participants' competence in practical gamma spectrometry. The seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 75 people participated; representing 34 different universities, commercial companies, research institutes and also all Nordic authorities. During the seminar several key issues for follow-up were identified and working groups for addressing the identified problems were established. The working groups were: 1) Uncertainties and detections of limits 2) True summing coincidence 3) Monte Carlo simulations and efficiency transfer 4) Absorption (density corrections and geometries) 5) Mobile gamma spectrometry systems 6) Nuclear forensics (on special samples and special parts of the spectra). The identified topics will form the basis for the agenda of the next seminar in 2010. There, the different working groups will be invited to present their ideas/solutions to the relevant problems. (author)

  11. GammaSem Proceedings - A Nordic seminar for users of gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, P. (ed.) (Institute for Energy Technology (IFE) (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority (STUK) (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy. Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (IS)); Israelson, C. (National Institute of Radiation Protection (Denmark))

    2010-03-15

    The project GammaSem was proposed to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and to establish a network of users of gamma spectrometry in the Nordic countries, thereby strengthening the collaboration and improving all participants' competence in practical gamma spectrometry. The seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 75 people participated; representing 34 different universities, commercial companies, research institutes and also all Nordic authorities. During the seminar several key issues for follow-up were identified and working groups for addressing the identified problems were established. The working groups were: 1) Uncertainties and detections of limits 2) True summing coincidence 3) Monte Carlo simulations and efficiency transfer 4) Absorption (density corrections and geometries) 5) Mobile gamma spectrometry systems 6) Nuclear forensics (on special samples and special parts of the spectra). The identified topics will form the basis for the agenda of the next seminar in 2010. There, the different working groups will be invited to present their ideas/solutions to the relevant problems. (author)

  12. Coincidence summing corrections for positron emitters in germanium gamma spectrometry

    International Nuclear Information System (INIS)

    Richardson, A.E.; Sallee, W.W.; New Mexico State Univ., Las Cruces

    1990-01-01

    For positron emitters, 511 keV annihilation quanta are in coincidence with other gamma rays in the decay scheme. If the positrons are not localized at the point of decay, annihilation quanta will be produced at a site some distance from the point of emission. The magnitude of the summing coincidence effect will depend upon the position of annihilation. A method for determining the magnitude of the summing effect for a single gamma of energy E in coincidence with the annihilation gammas from non-localized positrons has been developed which makes use of the counting data for the full energy peaks for both the gamma ray (E) and the 511 keV annihilation gammas. With this data and efficiency calibration data one can determine the average total efficiency for the annihilation positions from which 511 keV gammas originate, and thereby obtain the summing correction factor, SCF, for gamma ray (E). Application of the method to a 22 Na NIST standard gave excellent agreement of observed emission rates for the 1275 keV gamma with the NIST value for wide ranging degrees of positron localization having summing correction factors ranging from 1.021 to 1.505. The method was also applied successfully to 58 Co in neutron-irradiated nickel foils. The method shows promise as a check on the accuracy of the efficiency calibration for a particular detector geometry at the 511 keV energy and energies for other gammas associated with positron emission. (orig.)

  13. Proceedings of the workshop on multiple prompt gamma-ray analysis

    International Nuclear Information System (INIS)

    Ebihara, Mitsuru; Hatsukawa, Yuichi; Oshima, Masumi

    2006-10-01

    The workshop on 'Multiple Prompt Gamma-ray Analysis' was held on March 8, 2006 at Tokai. It is based on a project, 'Developments of real time, non-destructive ultra sensitive elemental analysis using multiple gamma-ray detections and prompt gamma ray analysis and its application to real samples', one of the High priority Cooperative Research Programs performed by Japan Atomic Energy Agency and the University of Tokyo. In this workshop, the latest results of the Multiple Prompt Gamma ray Analysis (MPGA) study were presented, together with those of Neutron Activation Analysis with Multiple Gamma-ray Detection (NAAMG). The 9 of the presented papers are indexed individually. (J.P.N.)

  14. The effect of gamma irradiation on the degree of ripening of mango by comparing the parameter of colour index, texture firmness and pH value

    International Nuclear Information System (INIS)

    Muhammad Hafiz Hanafi

    2012-01-01

    This study was carried out to determine the effect of low dose gamma irradiation on the ripening degree of cv Chokanan mangoes through the comparison of colour index changes, texture firmness and pH value. Harvested mature mango was studied through the storage period for 14 days. Dose level used were 0.00 kGy (control), 0.25 kGy, 0.50 kGy, 0.75 kGy and 1.00 kGy of gamma cell 220. All fruits were wrapped using plastic after irradiated. There was no change in 0 day. However, there are changes in colour index, firmness and pH value of fruits in after 3 days. Dose of 0.75 kGy and 1.00 kGy gave positive effect to storage extension period and rate deceleration compared to 0.00 kGy (control), 0.25 kGy and 0.50 kGy. After 10 days storage, 0.00, 0.25 and 0.50 kGy of fruits became rot which affects quality of organoleptic. Whereas 0.75 and 1.00 kGy still retained organoleptic quality . When the ripening rate of fruit was fast, this would lead to faster of the colour change. The firmness value of fruit became decrease and the value of pH was increase. (author)

  15. Two Dimensional Verification of the Dose Distribution of Gamma Knife Model C using Monte Carlo Simulation with a Virtual Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hoon; Kim, Yong-Kyun; Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Dong Geon; Choi, Joonbum; Jang, Jae Yeong [Hanyang University, Seoul (Korea, Republic of); Chung, Hyun-Tai [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Gamma Knife model C contains 201 {sup 60}Co sources located on a spherical surface, so that each beam is concentrated on the center of the sphere. In the last work, we simulated the Gamma Knife model C through Monte Carlo simulation code using Geant4. Instead of 201 multi-collimation system, we made one single collimation system that collects source parameter passing through the collimator helmet. Using the virtual source, we drastically reduced the simulation time to transport 201 gamma circle beams to the target. Gamma index has been widely used to compare two dose distributions in cancer radiotherapy. Gamma index pass rates were compared in two calculated results using the virtual source method and the original method and measured results obtained using radiocrhomic films. A virtual source method significantly reduces simulation time of a Gamma Knife Model C and provides equivalent absorbed dose distributions as that of the original method showing Gamma Index pass rate close to 100% under 1mm/3% criteria. On the other hand, it gives a little narrow dose distribution compared to the film measurement showing Gamma Index pass rate of 94%. More accurate and sophisticated examination on the accuracy of the simulation and film measurement is necessary.

  16. Gamma sensitivity of pressurized drift tubes

    International Nuclear Information System (INIS)

    Baranov, S.A.; Bojko, I.R.; Shelkov, G.A.; Ignatenko, M.A.

    1995-01-01

    Using a set of commonly used radioactive sources, the efficiency of pressurized drift tubes for gammas with energy from 5.9 keV up to 1.3 MeV has been measured. The tube was made of aluminium and filled with Ar, 15%CO 2 and 2.5%iC 4 H 10 gas mixture at 3 atm. The measured efficiency is compared with the results of the calculations in the frame of our simple model as well as with that of the Monte Carlo simulation using GEANT code. The results of our calculations are in agreement with experimental data, while GEANT simulation tends to give lower efficiency in the energy range of 200 keV γ <1300 keV. The average efficiency of the tube in the field of ATLAS gamma background is about 0.45%. 8 refs., 7 figs., 1 tab

  17. A new computationally-efficient computer program for simulating spectral gamma-ray logs

    International Nuclear Information System (INIS)

    Conaway, J.G.

    1995-01-01

    Several techniques to improve the accuracy of radionuclide concentration estimates as a function of depth from gamma-ray logs have appeared in the literature. Much of that work was driven by interest in uranium as an economic mineral. More recently, the problem of mapping and monitoring artificial gamma-emitting contaminants in the ground has rekindled interest in improving the accuracy of radioelement concentration estimates from gamma-ray logs. We are looking at new approaches to accomplishing such improvements. The first step in this effort has been to develop a new computational model of a spectral gamma-ray logging sonde in a borehole environment. The model supports attenuation in any combination of materials arranged in 2-D cylindrical geometry, including any combination of attenuating materials in the borehole, formation, and logging sonde. The model can also handle any distribution of sources in the formation. The model considers unscattered radiation only, as represented by the background-corrected area under a given spectral photopeak as a function of depth. Benchmark calculations using the standard Monte Carlo model MCNP show excellent agreement with total gamma flux estimates with a computation time of about 0.01% of the time required for the MCNP calculations. This model lacks the flexibility of MCNP, although for this application a great deal can be accomplished without that flexibility

  18. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  19. Positron imaging with multiwire proportional chamber-gamma converter hybrid detectors

    International Nuclear Information System (INIS)

    Chu, D.Y.H.

    1976-09-01

    A large area positron camera was developed using multiwire proportional chambers as detectors and electromagnetic delay lines for coordinate readout. Honeycomb structured gamma converters made of lead are coupled to the chambers for efficient gamma detection and good spatial resolution. Two opposing detectors, each having a sensitive area of 48 cm x 48 cm, are operated in coincidence for the detection of annihilation gammas (511 keV) from positron emitters. Detection efficiency of 4.2 percent per detector and spatial resolution of 6 to 7 mm FWHM at the mid-plane were achieved. The present camera operates at a maximum count rate of 24 K counts/min, limited by accidental coincidence. The theory for the gamma converter is presented along with a review of the operation of the multiwire proportional chamber and delay line readout. Calculated gamma converter efficiencies are compared with the measured results using a prototype test chamber. The characteristics of the positron camera system is evaluated, and the performance is shown to be consistent with calculation

  20. Calibration and simulation of a gamma array for DRAGON at ISAC

    CERN Document Server

    Gigliotti, D G; Hussein, A H

    2003-01-01

    A gamma ray detector has been built for the DRAGON facility at TRIUMF to detect the gamma ray emitted in astrophysically important proton and alpha radiative capture reactions. The gamma detector was designed to balance cost with maximum solid angle coverage and efficiency. To study the properties of the current design, GEANT simulations are being carried out and compared with prototype measurements using calibration sources and radioactive beams supplied by ISAC. Simulations will be compared with data allowing a realistic simulation to be produced. This modified simulation will then be used to provide efficiency predictions of the gamma array when an actual experiment's parameters are inputted. Using the simulated efficiency of the array, cross sections for radiative capture can be calculated from the measured gamma ray yields, for the individual reactions. The following will outline some initial results of background suppression of beam related experiments. Also shown, are some preliminary comparison of poi...

  1. Plutonium characterisation with prompt high energy gamma-rays from (n,gamma) reactions for nuclear warhead dismantlement verification

    Energy Technology Data Exchange (ETDEWEB)

    Postelt, Frederik; Gerald, Kirchner [Carl Friedrich von Weizsaecker-Centre for Science and Peace Research, Hamburg (Germany)

    2015-07-01

    Measurements of neutron induced gammas allow the characterisation of fissile material (i.e. plutonium and uranium), despite self- and additional shielding. Most prompt gamma-rays from radiative neutron capture reactions in fissile material have energies between 3 and 6.5 MeV. Such high energy photons have a high penetrability and therefore minimise shielding and self-absorption effects. They are also isotope specific and therefore well suited to determine the isotopic composition of fissile material. As they are non-destructive, their application in dismantlement verification is desirable. Disadvantages are low detector efficiencies at high gamma energies, as well as a high background of gammas which result from induced fission reactions in the fissile material, as well as delayed gammas from both, (n,f) and(n,gamma) reactions. In this talk, simulations of (n,gamma) measurements and their implications are presented. Their potential for characterising fissile material is assessed and open questions are addressed.

  2. Efficacy of gamma sterilization technique for biofertilizer carrier production

    International Nuclear Information System (INIS)

    Rallos, Roland V.; Rivera, Faye G.; Anarna, Julie A.; Rojales, Jacqueline S.

    2013-01-01

    Th use of gamma irradiation as sterilization technique for biofertilizer carrier is very efficient and practical especially in large scale production. The results of this study on the efficacy of gamma sterilization justify research on the effects of established doses of gamma irradiation on the physico-chemical properties of the clay-charcoal mixture

  3. Do Forwarders Improve Sustainability Efficiency? Evidence from a European DEA Malmquist Index Calculation

    Directory of Open Access Journals (Sweden)

    Matthias Klumpp

    2017-05-01

    Full Text Available Sustainability performance and efficiency is an important topic in transportation and for forwarders. This is shown, for example, by the fact that major logistics service providers LSP publish sustainability reports, often within the annual legal business report. However, in depth research is missing regarding the efficiency of forwarders regarding the established triple bottom line approach for sustainability, including economic, social, and ecology performance areas. This is especially true for a dynamic time-series perspective, as usually only static analyses for one point in time are presented (in most cases single business years. Therefore, the operations research technique of a data envelopment analysis (DEA Malmquist index calculation is used in order to provide a longitudinal calculation of efficiency, incorporating multiple objectives regarding the triple bottom line approach for European forwarders. Several indicators are tested, including total revenues and assets as input types, profit (EBIT and dividend volume (economic dimension, employment and gender equality in management (social, and carbon-equivalent emissions (environmental as output types.

  4. TH-CD-207A-10: Using the Gamma Index to Flag Changes in Anatomy During Radiation Therapy of Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schaly, B; Battista, J [London Regional Cancer Program, London, Ontario (Canada); Department of Medical Biophysics, Western University, London, Ontario Canada (Canada); Kempe, J; Mitchell, S [London Regional Cancer Program, London, Ontario (Canada); Venkatesan, V [London Regional Cancer Program, London, Ontario (Canada); Schulich School of Medicine and Dentistry, Western University, London, Ontario (Canada)

    2016-06-15

    Purpose: This article presents a fast algorithm for comparing 3-D anatomy from Cone-Beam CT (CBCT) imaging using the gamma comparison index and to demonstrate how this can be used to flag patients for possible re-planning of treatment. Methods: CBCT scans acquired on a Varian linear accelerator during treatment were used as input to the gamma comparator using thresholds of 5 mm distance to agreement and 30 Hounsfield Unit CT number difference. The fraction 1 CBCT study was initially used as the reference. Should there be a re-plan during treatment, the reference resets to the CBCT study acquired on the day 1 of the re-plan. Histograms of failing pixels (γ > 1) were generated from each 3-D gamma map. An indicator of anatomy congruence, the match quality parameter (MQP), was derived from failed pixel histograms using the 90th percentile gamma value. The MQP was plotted versus fraction number and related to actual repeat computed tomography (re-CT) order dates as decided by a radiation oncologist. From this, decision criteria were derived for the algorithm to “trigger” re-CT consideration and predictive power was scored using receiver-operator characteristic (ROC) analysis. Results: The MQP plot generally showed that the on-line match from CBCT image guidance deteriorated as the treatment progressed due to weight loss and tumor regression. The optimized MQP criteria for triggering re-CT consideration demonstrated high sensitivity and specificity, consistent with actual re-CT order dates within ± 3 fractions. Out of 20 patients that were actually re-planned, the algorithm failed to trigger a re-CT recommendation only twice and this was caused by CBCT ring artifacts. Conclusion: We have demonstrated that gamma comparisons can be used to evaluate CBCT-acquired anatomy pairs and, from this, an algorithm can be “trained” to flag patients for possible re-planning in a manner consistent with local radiation oncology practice.

  5. Research on energy efficiency design index for sea-going LNG carriers

    Science.gov (United States)

    Lin, Yan; Yu, Yanyun; Guan, Guan

    2014-12-01

    This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters—fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.

  6. Automatic processing of gamma ray spectra employing classical and modified Fourier transform approach

    International Nuclear Information System (INIS)

    Rattan, S.S.; Madan, V.K.

    1994-01-01

    This report describes methods for automatic processing of gamma ray spectra acquired with HPGe detectors. The processing incorporated both classical and signal processing approach. The classical method was used for smoothing, detecting significant peaks, finding peak envelope limits and a proposed method of finding peak limits, peak significance index, full width at half maximum, detecting doublets for further analysis. To facilitate application of signal processing to nuclear spectra, Madan et al. gave a new classification of signals and identified nuclear spectra as Type II signals, mathematically formalized modified Fourier transform and pioneered its application to process doublet envelopes acquired with modern spectrometers. It was extended to facilitate routine analysis of the spectra. A facility for energy and efficiency calibration was also included. The results obtained by analyzing observed gamma-ray spectra using the above approach compared favourably with those obtained with SAMPO and also those derived from table of radioisotopes. (author). 15 refs., 3 figs., 3 tabs

  7. High slope efficiency and high refractive index change in direct-written Yb-doped waveguide lasers with depressed claddings.

    Science.gov (United States)

    Palmer, Guido; Gross, Simon; Fuerbach, Alexander; Lancaster, David G; Withford, Michael J

    2013-07-15

    We report the first Yb:ZBLAN and Yb:IOG10 waveguide lasers fabricated by the fs-laser direct-writing technique. Pulses from a Titanium-Sapphire laser oscillator with 5.1 MHz repetition rate were utilized to generate negative refractive index modifications in both glasses. Multiple modifications were aligned in a depressed cladding geometry to create a waveguide. For Yb:ZBLAN we demonstrate high laser slope efficiency of 84% with a maximum output power of 170 mW. By using Yb:IOG10 a laser performance of 25% slope efficiency and 72 mW output power was achieved and we measured a remarkably high refractive index change exceeding Δn = 2.3 × 10(-2).

  8. Effects of commercial doses of {gamma}-irradiation on DVI (Dormancy overcoming Visual Index) of red garlic clove (Allium sativum L.)

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, C.N.; Mujica, M.B.; Orioli, G.A. [Universidad Nacional del Sur, Bahia Blanca (Argentina). Dept. de Agronomia; Croci, C.A. [Universidad Nacional del Sur, Bahia Blanca (Argentina). Lab. de Radioisotopos

    1995-12-31

    The growth inhibitor effect of commercial doses of gamma rays was analyzed on the DVI evolution during garlic post-harvest storage. The DVI behaviour of irradiated and non-irradiated samples was identical throughout the rest period (90 d.p.h.) and the beginning of sprouting (120 d.p.h.). At 180 d.p.h. non-irradiated samples showed a sharp increase of DVI, reaching the maximum value at 240 d.p.h. At the same time irradiated samples only showed a slight index increase, hardly reaching 60%. These results are discussed in relation to the use of DVI as a possible indicator of irradiation treatment on garlic bulbs. (author). 9 refs, 3 figs.

  9. Solid state scintillators for gamma spectrometry. Studio di scintillatori a stato solido per spettrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    La Mela, G; Torrisi, M [Istituto Nazionale di Fisica Nucleare, Catania (Italy)

    1991-01-01

    Using different scintillator crystals, measurements of energy resolution and detection efficiency have been performed to detect gamma rays of energy ranging between 500 en 1550 KeV. This investigation is devoted to characterize the best systems to detect photons coming from positron annihilation processes, such as a PET apparatus where the medical image is the final aim of the investigation, and gamma emission from radioisotopes of biomedical interest.

  10. Isothermal deformation of gamma titanium aluminide

    International Nuclear Information System (INIS)

    Srinivasan, R.; Singh, J.P.; Tuval, E.; Weiss, I.

    1996-01-01

    Gamma titanium aluminide has received considerable attention in recent years from the automotive industry as a potential material for making rotating and reciprocating components to produce a quieter and more efficient engine. The objectives of this study were to identify processing routes for the manufacture of automobile valves from gamma titanium aluminide. The issues considered were microstructure and composition of the material, and processing parameters such as deformation rates, temperatures, and total deformation. This paper examines isothermal deformation of gamma titanium aluminide in order to develop a processing window for this type of material

  11. Theta–gamma coordination between anterior cingulate and prefrontal cortex indexes correct attention shifts

    Science.gov (United States)

    Voloh, Benjamin; Valiante, Taufik A.; Everling, Stefan; Womelsdorf, Thilo

    2015-01-01

    Anterior cingulate and lateral prefrontal cortex (ACC/PFC) are believed to coordinate activity to flexibly prioritize the processing of goal-relevant over irrelevant information. This between-area coordination may be realized by common low-frequency excitability changes synchronizing segregated high-frequency activations. We tested this coordination hypothesis by recording in macaque ACC/PFC during the covert utilization of attention cues. We found robust increases of 5–10 Hz (theta) to 35–55 Hz (gamma) phase–amplitude correlation between ACC and PFC during successful attention shifts but not before errors. Cortical sites providing theta phases (i) showed a prominent cue-induced phase reset, (ii) were more likely in ACC than PFC, and (iii) hosted neurons with burst firing events that synchronized to distant gamma activity. These findings suggest that interareal theta–gamma correlations could follow mechanistically from a cue-triggered reactivation of rule memory that synchronizes theta across ACC/PFC. PMID:26100868

  12. MEASURES OF EFFICIENCY AND INVESTMENTS RETURN: AN STUDY OF BRAZILIAN ELECTRICITY DISTRIBUTORS WITH DATA ENVELOPMENT ANALYSIS, MALMQUIST INDEX AND ROI

    Directory of Open Access Journals (Sweden)

    Valter Saurin

    2013-03-01

    Full Text Available This paper aims to determine, in a group of companies from the Brazilian electric sector, if there is a relationship between the return on investment (ROI and the concept of efficiency estimated by the method Data Envelopment Analysis (DEA, as well as evaluating the growth of productivity based on Malmquist Index (Fare et al, 1996. The hypothesis is that firms that had return on investment higher during certain period of time are those employed their resources efficiently in getting their outputs (DEA efficient. The input (1 Products (5 DEA model correspond to the operating cost (I, the network length (km, the number of consumers and the market billed high, medium and low voltage, respectively. The sample consisted of 31 companies of Brazilian electricity distribution and timing of the study was from 2007 to 2009. We calculated the Malmquist index (M0, represented by the change in total factor productivity (TFPC, which is composed by the evolution of technical efficiency (EC and the change in the technological frontier (TC of the companies were also determined ROI for each period. We calculated the correlation between the TFPC, TC, EC, score the DEA and the ROI for the period 2007 to 2009. The results showed a positive correlation, although weak, between efficiency change and the indexes mentioned above, rejecting the initial hypothesis

  13. Continued Development of a Soft Gamma-Ray Concentrator

    Science.gov (United States)

    Bloser, Peter

    We propose to continue our development of a concept for a soft gamma-ray (E > 100 keV) concentrator using thin-film multilayer structures. Alternating layers of low- and high-density materials will channel soft gamma-ray photons via total external reflection. A suitable arrangement of bent structures will then concentrate the incident radiation to a point. Gamma-ray optics made in this way offer the potential for soft gamma-ray telescopes with focal lengths of less than 10 m, removing the need for formation flying spacecraft and opening the field up to balloon-borne instruments. Under previous APRA funding we have been investigating methods for efficiently producing such multilayer structures and modeling their performance. We now propose to pursue magnetron sputtering (MS) techniques to quickly produce structures with the required smoothness and thickness, to measure their channeling efficiency and compare with calculations, and to design a "lens" with optimized bandpass and throughput and predict its scientific performance. If successful, this work will confirm that this innovative optics concept is suitable for a balloon-born soft gamma-ray telescope with unprecedented sensitivity.

  14. Development of gamma camera and application to decontamination

    International Nuclear Information System (INIS)

    Yoshida, Akira; Moro, Eiji; Takahashi, Isao

    2013-01-01

    A gamma camera has been developed to support recovering from the contamination caused by the accident of Fukushima Dai-ichi Nuclear Power Plant of Tokyo Electric Power Company. The gamma camera enables recognition of the contamination by visualizing radioactivity. The gamma camera has been utilized for risk communication (explanation to community resident) at local governments in Fukushima. From now on, the gamma camera will be applied to solve decontaminations issues; improving efficiency of decontamination, visualizing the effect of decontamination work and reducing radioactive waste. (author)

  15. Efficiency of cement - based low - weight shielding materials for Cs-137 gamma rays

    International Nuclear Information System (INIS)

    Satty, H. E. M.

    2014-10-01

    Due to the development of nuclear technology and use of technologies in various field of industry, medicine and research against ionizing radiation is one of the most important topics in this field. The purpose of this work is to reduce the dose rate from radioactive sources. The exposure to gamma radiation is leading to several health effects as the result of absorption by the human body. The frequently used shielding material for gamma rays is lead. In spite of its effectiveness and high mass attenuation coefficient, lower weight gamma shielding materials are required. In this effectiveness of three materials: carbon and mixture (50% carbon + 50% cement) was studied and compared to that of lead. The results were obtained in terms of the variations of the transmitted intensity. This is done using a gamma spectroscopy system.(Author)

  16. Status of development of the Gamma Ray Energy Tracking Array (GRETA)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, I.Y.; Schmid, G.J.; Vetter, K. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1996-12-31

    The current generation of large gamma-ray detector arrays, Gammasphere, Eurogam and GASP, are based on modules of Compton suppressed Ge detectors. Due to the solid angle occupied by the Compton shields and to gamma rays escaping the detector, the total peak efficiency of such a design is limited to about 20% for a 1.3 MeV gamma ray. A shell consisting of closely packed Ge detectors has been suggested as the solution to the efficiency limitation. In this case, the entire solid angle is covered by Ge detectors, and by adding the signal from neighboring detectors, the escaped energy is recovered and much higher efficiency can be achieved (e.g. 60% for a 1.3 MeV gamma ray). However, for high multiplicity cascades, the summing of two gamma rays hitting neighboring detectors reduces the efficiency and increases the background. In order to reduce this summing, a large number of detectors is required. For example, with a multiplicity of 25, one needs about 1500 detectors to keep the probability of false summing below 10% and the cost of such a detector array will be prohibitive. Rather than such an approach, the authors are developing a new concept for a gamma-ray array; a shell of closely-packed Ge detectors consisting of 100-200 highly-segmented elements. The high granularity of the segmented Ge detector enables the authors to resolve each of the scattering interactions and determine its position and energy. A tracking algorithm, using the position and energy information, will then identify the interactions belonging to a particular gamma ray and its energy is obtained by summing only these interactions. Such an array can reach a total efficiency about 60%, with a resolving power 1000 times higher than that of current arrays.

  17. Neural network consistent empirical physical formula construction for neutron–gamma discrimination in gamma ray tracking

    International Nuclear Information System (INIS)

    Yildiz, Nihat; Akkoyun, Serkan

    2013-01-01

    Highlights: ► Detector responses in neutron–gamma discrimination were estimated by neural networks. ► Novel consistent neural network empirical physical formulas (EPFs) were constructed for detector responses. ► The EPFs are of explicit mathematical functional form. ► The EPFs can be used to derive various physical functions relevant to neutron–gamma discrimination in gamma ray tracking. -- Abstract: Gamma ray tracking is an efficient detection technique in studying exotic nuclei which lies far from beta stability line. To achieve very powerful and extraordinary resolution ability, new detectors based on gamma ray tracking are currently being developed. To reach this achievement, the neutron–gamma discrimination in these detectors is also an important task. In this paper, by suitable layered feedforward neural networks (LFNNs), we have constructed novel and consistent empirical physical formulas (EPFs) for some highly nonlinear detector counts measured in neutron–gamma discrimination. The detector counts data used in the discrimination was actually borrowed from our previous paper. The counts used here had been originally measured versus the following parameters: energy deposited in the first interaction points, difference in the incoming direction of initial gamma rays, and finally figure of merit values of the clusters determined by tracking. The LFNN–EPFs are of explicit mathematical functional form. Therefore, by various suitable operations of mathematical analysis, these LFNN–EPFs can be used to derivate further physical functions which might be potentially relevant to neutron–gamma discrimination performance of gamma ray tracking.

  18. Indexing mergers and acquisitions

    OpenAIRE

    Gang, Jianhua; Guo, Jie (Michael); Hu, Nan; Li, Xi

    2017-01-01

    We measure the efficiency of mergers and acquisitions by putting forward an index (the ‘M&A Index’) based on stochastic frontier analysis. The M&A Index is calculated for each takeover deal and is standardized between 0 and 1. An acquisition with a higher index encompasses higher efficiency. We find that takeover bids with higher M&A Indices are more likely to succeed. Moreover, the M&A Index shows a strong and positive relation with the acquirers’ post-acquisition stock perfo...

  19. GEOINFORMATION ANALYSIS OF THE INDEX OF BIOLOGICAL EFFICIENCY OF CLIMATE AS CRITERION FOR EVALUATION OF POTENTIAL STABILITY OF THE LANDSCAPE

    Directory of Open Access Journals (Sweden)

    A. N. Ogurtsov

    2017-01-01

    Full Text Available The article considers indicator approach to assessment of potential stability of landscapes. As an example of integrated criterion the index of climate biological efficiency (TK has been used. Calculations of TK index for assessment of stability of landscapes have been executed for the territory of Tver Region. Cartograms of TK index and its components have been made. Geospatial analysis has been carried out and estimates of potential stability of landscapes are given. The example of mapping and calculation of the TK index serves as a starting point for using it in multi-criteria assessment of the state and emergent properties of geosystems built on the principles of ASPID-methodology. This example reflects the possibility of using the indicator approach in the first stage of the study of resistance to changes in the parameters of natural regime for the subsequent multicriteria and integral assessment of resistance to changes in the parameters of natural and anthropogenic regimes of geosystems functioning. The use of the index of climate biological efficiency as an indicator of sustainability will make it possible to actively use it in future in geoecological research.

  20. Specialized software utilities for gamma ray spectrometry. Final report of a co-ordinated research project 1996-2000

    International Nuclear Information System (INIS)

    2002-03-01

    A Co-ordinated Research Project (CRP) on Software Utilities for Gamma Ray Spectrometry was initiated by the International Atomic Energy Agency in 1996 for a three year period. In the CRP several basic applications of nuclear data handling were assayed which also dealt with the development of PC computer codes for various spectrometric purposes. The CRP produced several software packages: for the analysis of low level NaI spectra; user controlled analysis of gamma ray spectra from HPGe detectors; a set of routines for the definition of the detector resolution function and for the unfolding of experimental annihilation spectra; a program for the generation of gamma ray libraries for specific applications; a program to calculate true coincidence corrections; a program to calculate full-energy peak efficiency calibration curve for homogenous cylindrical sample geometries including self-attenuation correction; and a program for the library driven analysis of gamma ray spectra and for the quantification of radionuclide content in samples. In addition, the CRP addressed problems of the analysis of naturally occurring radioactive soil material gamma ray spectra, questions of quality assurance and quality control in gamma ray spectrometry, and verification of the expert system SHAMAN for the analysis of air filter spectra obtained within the framework of the Comprehensive Nuclear Test Ban Treaty. This TECDOC contains 10 presentations delivered at the meeting with the description of the software developed. Each of the papers has been indexed separately

  1. Study of the gamma radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1949-12-01

    A Geiger counter study has been made of the ..gamma.. radiation of ionium. Eleven quanta of the L radiation of radium were observed for every hundred ..cap alpha.. disintegrations, and three ..gamma.. rays were found with energies of 68, 140, and 240 keV at a rate of 0.85, 0.33, 0.05 quanta, respectively, for 100 disintegrations. It is noted that the radiation spectrum of ionium as a whole is difficult to interpret. In the course of this work, the author calculated the efficiency of a thin-walled aluminum counter, both for the L radiation of radium and for ..gamma.. rays of 68 keV. The author also measured, for soft radiation, the ratio between the efficiency of a thin-walled aluminum counter and that of a similar counter lined with 0.11 mm of lead.

  2. Gamma Radiation to Increase Efficiency of Bacillus thuringiensis Thai Strain for Insect Pets Control

    International Nuclear Information System (INIS)

    Chanpaisaeng, Jariya; Keawsompong, Suttipun; Piadang, Nattaya; Tephan, Prakai; Keawchingduang, Wannapa

    2006-09-01

    Bacillus thuringiensis (Bt) isolates JCPT16 and JCPT68 were gamma-irradiated at 2, 4, 6 and 8 kGy. The efficiency of these Bt isolates on S. litura control was also undertaken. It was found that the 4 kGy irradiated JCPT16 isolate had lowest LC 50 of 6.6x10 3 spore/ml while the non-irradiated JCPT 16 isolate had LC 50 of 6.2x10 3 spore/ml. Whereas the irradiated JCPT68 isolate at 8 kGy was noticed to have the lowest LC 50 of 2.7 x 10 3 spores/ml, the non-irradiated JCPT68 had LC 50 of 1.8x10 3 spores/ml. The efficiency test of B. thuringiensis isolate on S. exigua showed that the 2 kGy irradiated JCPT16 isolate had the lowest LC 50 of 2.52x10 4 spores/ml while the non-irradiated JCPT16 isolate had LC 50 of 6.04x10 3 spores/ml. The irradiated JCPT68 isolate at 4 kGy had the lowest LC 50 of 5.41x10 4 spores/ml, the non irradiated JCPT68 had LC 50 of 1.51x10 4 spores/ml. According to LC 50 values, there were no significant differences of efficiency on S. litura and S. exigua control among Bt isolates irradiated at various concentrations. The isolate JCPT16, JCPT35, JCPT50 and JCPT68 irradiated at dose of 10 kGy showed higher UV tolerance. After expose by UV ray, most of irradiated isolates still displayed high efficiency of controlling S. litura, S. exigua and Plutella xylostell.

  3. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  4. Gamma irradiation treatment of secondary sewage effluent

    International Nuclear Information System (INIS)

    Vajdic, A.H.

    The operation and monitoring of a pilot scale Co-60 gamma irradiation unit treating secondary sewage effluent is described. The disinfecting efficiency of the unit is compared to that of an experimental 'ideal' chlorination unit and to the plant chlorination process. A cost estimate for disinfection by gamma irradiation on a full plant scale is included. (author)

  5. Gamma-glutamyltransferase, fatty liver index and hepatic insulin resistance are associated with incident hypertension in two longitudinal studies.

    Science.gov (United States)

    Bonnet, Fabrice; Gastaldelli, Amalia; Pihan-Le Bars, Florence; Natali, Andrea; Roussel, Ronan; Petrie, John; Tichet, Jean; Marre, Michel; Fromenty, Bernard; Balkau, Beverley

    2017-03-01

    We hypothesized that liver markers and the fatty liver index (FLI) are predictive of incident hypertension and that hepatic insulin resistance plays a role. The association between liver markers and incident hypertension was analysed in two longitudinal studies of normotensive individuals, 2565 from the 9-year data from an epidemiological study on the insulin resistance cohort and the 321 from the 3-year 'Relationship between Insulin Sensitivity and Cardiovascular disease' cohort who had a measure of endogenous glucose production. The FLI is calculated from BMI, waist circumference, triglycerides and gamma-glutamyltransferase (GGT) and the hepatic insulin resistance index from endogenous glucose production and fasting insulin. The incidence of hypertension increased across the quartiles groups of both baseline GGT and alanine aminotransferase. After adjustment for sex, age, waist circumference, fasting glucose, smoking and alcohol intake, only GGT was significantly related with incident hypertension [standardized odds ratio: 1.21; 95% confidence interval (1.10-1.34); P = 0.0001]. The change in GGT levels over the follow-up was also related with an increased risk of hypertension, independently of changes in body weight. FLI analysed as a continuous value, or FLI at least 60 at baseline were predictive of incident hypertension in the multivariable model. In the RISC cohort, the hepatic insulin resistance index was positively related with the risk of 3-year incident hypertension [standardized odds ratio: 1.54 (1.07-2.22); P = 0.02]. Baseline GGT and FLI, as well as an increase in GGT over time, were associated with the risk of incident hypertension. Enhanced hepatic insulin resistance predicted the onset of hypertension and may be a link between liver markers and hypertension.

  6. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  7. Tensorial dynamic time warping with articulation index representation for efficient audio-template learning.

    Science.gov (United States)

    Le, Long N; Jones, Douglas L

    2018-03-01

    Audio classification techniques often depend on the availability of a large labeled training dataset for successful performance. However, in many application domains of audio classification (e.g., wildlife monitoring), obtaining labeled data is still a costly and laborious process. Motivated by this observation, a technique is proposed to efficiently learn a clean template from a few labeled, but likely corrupted (by noise and interferences), data samples. This learning can be done efficiently via tensorial dynamic time warping on the articulation index-based time-frequency representations of audio data. The learned template can then be used in audio classification following the standard template-based approach. Experimental results show that the proposed approach outperforms both (1) the recurrent neural network approach and (2) the state-of-the-art in the template-based approach on a wildlife detection application with few training samples.

  8. Development of gallium arsenide gamma spectrometric detector

    International Nuclear Information System (INIS)

    Kobayashi, T.; Kuru, I.

    1975-03-01

    measuring gamma-ray spectrum with GaAs detector. However, gamma-ray counting efficiency of the detector was not enough to built portable type instrument of gamma-ray spectrometer used for routine works of nuclear safeguards. In order to improve gamma-ray counting efficiency of the detector, double-epitaxial-layer detector has been studied. The preliminary results showed that the improvement of the detector gamma-ray counting efficiency was possible by using double-epitaxial-layer structure. It was also clarified that the good quality GaAs crystal was a key to obtaining a low noise, good charge collection detector

  9. Solid state scintillators for gamma spectrometry

    International Nuclear Information System (INIS)

    La Mela, G.; Torrisi, M.

    1991-01-01

    Using different scintillator crystals, measurements of energy resolution and detection efficiency have been performed to detect gamma rays of energy ranging between 500 en 1550 KeV. This investigation is devoted to characterize the best systems to detect photons coming from positron annihilation processes, such as a PET apparatus where the medical image is the final aim of the investigation, and gamma emission from radioisotopes of biomedical interest

  10. Validation by theoretical approach to the experimental estimation of efficiency for gamma spectrometry of gas in 100 ml standard flask

    International Nuclear Information System (INIS)

    Mohan, V.; Chudalayandi, K.; Sundaram, M.; Krishnamony, S.

    1996-01-01

    Estimation of gaseous activity forms an important component of air monitoring at Madras Atomic Power Station (MAPS). The gases of importance are argon 41 an air activation product and fission product noble gas xenon 133. For estimating the concentration, the experimental method is used in which a grab sample is collected in a 100 ml volumetric standard flask. The activity of gas is then computed by gamma spectrometry using a predetermined efficiency estimated experimentally. An attempt is made using theoretical approach to validate the experimental method of efficiency estimation. Two analytical models named relative flux model and absolute activity model were developed independently of each other. Attention is focussed on the efficiencies for 41 Ar and 133 Xe. Results show that the present method of sampling and analysis using 100 ml volumetric flask is adequate and acceptable. (author). 5 refs., 2 tabs

  11. Determination of Carbamate and Organophosphorus Pesticides in Vegetable Samples and the Efficiency of Gamma-Radiation in Their Removal

    Directory of Open Access Journals (Sweden)

    Muhammed Alamgir Zaman Chowdhury

    2014-01-01

    Full Text Available In the present study, the residual pesticide levels were determined in eggplants (Solanum melongena (n=16, purchased from four different markets in Dhaka, Bangladesh. The carbamate and organophosphorus pesticide residual levels were determined by high performance liquid chromatography (HPLC, and the efficiency of gamma radiation on pesticide removal in three different types of vegetables was also studied. Many (50% of the samples contained pesticides, and three samples had residual levels above the maximum residue levels determined by the World Health Organisation. Three carbamates (carbaryl, carbofuran, and pirimicarb and six organophosphates (phenthoate, diazinon, parathion, dimethoate, phosphamidon, and pirimiphos-methyl were detected in eggplant samples; the highest carbofuran level detected was 1.86 mg/kg, while phenthoate was detected at 0.311 mg/kg. Gamma radiation decreased pesticide levels proportionately with increasing radiation doses. Diazinon, chlorpyrifos, and phosphamidon were reduced by 40–48%, 35–43%, and 30–45%, respectively, when a radiation strength of 0.5 kGy was utilized. However, when the radiation dose was increased to 1.0 kGy, the levels of the pesticides were reduced to 85–90%, 80–91%, and 90–95%, respectively. In summary, our study revealed that pesticide residues are present at high amounts in vegetable samples and that gamma radiation at 1.0 kGy can remove 80–95% of some pesticides.

  12. Methods for fitting of efficiency curves obtained by means of HPGe gamma rays spectrometers; Metodos de ajuste de curvas de eficiencia obtidas por meio de espectrometros de HPGe

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Vanderlei

    2002-07-01

    The present work describes a few methodologies developed for fitting efficiency curves obtained by means of a HPGe gamma-ray spectrometer. The interpolated values were determined by simple polynomial fitting and polynomial fitting between the ratio of experimental peak efficiency and total efficiency, calculated by Monte Carlo technique, as a function of gamma-ray energy. Moreover, non-linear fitting has been performed using a segmented polynomial function and applying the Gauss-Marquardt method. For the peak area obtainment different methodologies were developed in order to estimate the background area under the peak. This information was obtained by numerical integration or by using analytical functions associated to the background. One non-calibrated radioactive source has been included in the curve efficiency in order to provide additional calibration points. As a by-product, it was possible to determine the activity of this non-calibrated source. For all fittings developed in the present work the covariance matrix methodology was used, which is an essential procedure in order to give a complete description of the partial uncertainties involved. (author)

  13. Assessing Green Development Efficiency of Municipalities and Provinces in China Integrating Models of Super-Efficiency DEA and Malmquist Index

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2015-04-01

    Full Text Available In order to realize economic and social green development, to pave a pathway towards China’s green regional development and develop effective scientific policy to assist in building green cities and countries, it is necessary to put forward a relatively accurate, scientific and concise green assessment method. The research uses the CCR (A. Charnes & W. W. Cooper & E. Rhodes Data Envelopment Analysis (DEA model to obtain the green development frontier surface based on 31 regions’ annual cross-section data from 2008–2012. Furthermore, in order to classify the regions whereby assessment values equal to 1 in the CCR model, we chose the Super-Efficiency DEA model for further sorting. Meanwhile, according to the five-year panel data, the green development efficiency changes of 31 regions can be manifested by the Malmquist index. Finally, the study assesses the reasons for regional differences; while analyzing and discussing the results may allude to a superior green development pathway for China.

  14. Energy efficiency index to artificially conditioned buildings; Indice de eficiencia energetica para edificios climatizados artificialmente

    Energy Technology Data Exchange (ETDEWEB)

    Jota, Patricia Romeiro da Silva; Santos, Carla da Silva; Costa, Kelly Luciene C. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEMIG/CEFET), Belo Horizonte, MG (Brazil). Centro de Pesquisa em Energia Inteligente

    2010-07-01

    Conditioning buildings has been growing in number and are responsible for a significant portion of the energy used worldwide. The building energy use can be measured by the index of energy performance and specific fuel consumption (EC). The specific consumption is an index where the energy is normalized by the factors that affect energy use in order to obtain an index to explain variations in consumption. In this paper, we present a methodology to obtain a specific consumption that takes into account one of the factors that most affect energy use in these buildings, that is, the external temperature. The study is based on analysis of consumption of air conditioning system according to temperature. Through this analysis we obtain a function to facilitate the standardization of energy use, depending on the temperature outside. This methodology was tested in previous work on real buildings without stratification of energy, and this work will be presented a case study of a building whose energy measurement is stratified. The proposed index is the ratio between the energy consumption of air conditioning system corrected by the temperature through the function K(T). It was possible to demonstrate the efficiency of the index to eliminate the effect of temperature and thus to evaluate the evolution of specific consumption over the months analyzed. (author)

  15. Evaluation of the Detection Efficiency of LYSO Scintillator in the Fiber-Optic Radiation Sensor

    Directory of Open Access Journals (Sweden)

    Chan Hee Park

    2014-01-01

    Full Text Available The aim of this study was to develop and evaluate fiber-optic sensors for the remote detection of gamma rays in areas that are difficult to access, such as a spent fuel pool. The fiber-optic sensor consists of a light-generating probe, such as scintillators for radiation detection, plastic optical fibers, and light-measuring devices, such as PMT. The (Lu,Y2SiO5:Ce(LYSO:Ce scintillator was chosen as the light-generating probe. The (Lu,Y2SiO5:Ce(LYSO:Ce scintillator has higher scintillation efficiency than the others and transmits light well through an optical fiber because its refraction index is similar to the refractive index of the optical fiber. The fiber-optic radiation sensor using the (Lu,Y2SiO5:Ce(LYSO:Ce scintillator was evaluated in terms of the detection efficiency and reproducibility for examining its applicability as a radiation sensor.

  16. Advances in gamma-ray burst astronomy

    International Nuclear Information System (INIS)

    Cline, T.L.; Desai, U.D.

    1976-01-01

    Work at Goddard is presently being carried out in three major areas of gamma-ray burst research: (1) A pair of simultaneously operating 0.8-m 2 burst detectors were successfully balloon-borne at locations 800 miles apart on 9 May, 1975, each to atmospheric depths of 3 to 4 g cm -2 , for a 20-h period of coincident data coverage. This experiment investigates the size spectrum of bursts in the 10 -7 to 10 -6 erg cm -2 size region where dozens of events per day are expected on a -1.5 index integral power-law extrapolation. Considerable separation in latitude was used to avoid possible atmospheric and auroral secondary effects. Its results are not yet available. (2) A deep-space burst detector, the first spacecraft instrument built specifically for gamma-ray burst studies, was recently successfully integrated into the Helios-B space probe. Its use at distances of up to 2 AU will make possible the first high-resolution directional study of gamma-ray burst source locations. Similar modifications to several other space vehicles are also being prepared. (3) The gamma-ray instrument on the IMP-7 satellite is presently the most sensitive burst detector still operating in orbit. Its results have shown that all measured event-average energy spectra are consistent with being alike. Using this characteristic spectrum to select IMP-7 candidate events of smaller size than those detected using other spacecraft in coincidence, a size spectrum is constructed which fits the -1.5 index power law down to 2.5 x 10 -5 erg cm -2 per event, at an occurrence rate of about once per month. (Auth.)

  17. Efficient Asymmetric Index Encapsulation Scheme for Anonymous Content Centric Networking

    Directory of Open Access Journals (Sweden)

    Rong Ma

    2017-01-01

    Full Text Available Content Centric Networking (CCN is an effective communication paradigm that well matches the features of wireless environments. To be considered a viable candidate in the emerging wireless networks, despite the clear benefits of location-independent security, CCN must at least have parity with existing solutions for confidential and anonymous communication. This paper designs a new cryptographic scheme, called Asymmetric Index Encapsulation (AIE, that enables the router to test whether an encapsulated header matches the token without learning anything else about both of them. We suggest using the AIE as the core protocol of anonymous Content Centric Networking. A construction of AIE which strikes a balance between efficiency and security is given. The scheme is proved to be secure based on the DBDH assumption in the random oracle with tight reduction, while the encapsulated header and the token in our system consist of only three elements.

  18. Economics of gamma irradiation processing

    International Nuclear Information System (INIS)

    Tani, Toshio

    1980-01-01

    The gamma-ray irradiation business started at the Takasaki Laboratory of Japan Atomic Energy Research Institute. The irradiation facilities were constructed thereafter at various sites. The facilities must accept various types of irradiation, and must be constructed as multi-purpose facilities. The cost of irradiation consists of the cost of gamma sources, construction expense, personnel expense, management expense, and bank interest. Most of the expenses are considered to be fixed expense, and the amount of irradiation treatment decides the original costs of work. The relation between the irradiation dose and the construction expense shows the larger facility is more economical. The increase of amount of treatment reduces the original cost. The utilization efficiency becomes important when the amount of treatment and the source intensity exceed some values. The principal subjects of gamma-ray irradiation business are the sterilization of medical tools and foods for aseptic animals, the improvement of quality of plastic goods, and the irradiation of foods. Among them, the most important subject is the sterilization of medical tools. The cost of gamma irradiation per m 3 in still more expensive than that by ethylene oxide gas sterilization. However, the demand of gamma-ray irradiation is increasing. For the improvement of quality of plastic goods, electron irradiation is more favourable than the gamma irradiation. In near future, the economical balance of gamma irradiation can be achieved. (Kato, T.)

  19. Gamma spectroscopy of the isotope 253No

    International Nuclear Information System (INIS)

    Kalaninova, Z.

    2009-01-01

    The first part deals with the evaluation of the relative and absolute efficiency of detectors for the registration of gamma radiation to separator SHIP at GSI Darmstadt (Germany). In the second part we discussed the decay alpha-gamma coincidence spectroscopy of isotope 253 No. In conclusion, the basic characteristics of deexcitation of K-isomeric state in isotope 253 No are evaluated. Only sort abstract is published.

  20. Power industry restructuring and eco-efficiency changes: A new slacks-based model in Malmquist–Luenberger Index measurement

    International Nuclear Information System (INIS)

    Arabi, Behrouz; Munisamy, Susila; Emrouznejad, Ali; Shadman, Foroogh

    2014-01-01

    Measuring variations in efficiency and its extension, eco-efficiency, during a restructuring period in different industries has always been a point of interest for regulators and policy makers. This paper assesses the impacts of restructuring of procurement in the Iranian power industry on the performance of power plants. We introduce a new slacks-based model for Malmquist–Luenberger (ML) Index measurement and apply it to the power plants to calculate the efficiency, eco-efficiency, and technological changes over the 8-year period (2003–2010) of restructuring in the power industry. The results reveal that although the restructuring had different effects on the individual power plants, the overall growth in the eco-efficiency of the sector was mainly due to advances in pure technology. We also assess the correlation between efficiency and eco-efficiency of the power plants, which indicates a close relationship between these two steps, thus lending support to the incorporation of environmental factors in efficiency analysis. - Highlights: • We introduce a new slack-based model incorporating bad outputs to measure eco-efficiency. • Eco-efficiency change of power plants is measured over a restructuring period. • A success to enhance the eco-efficiency is revealed. • A close relationship between efficiency and eco-efficiency is shown

  1. Effect of gamma irradiation, evaporation retardants and transpiration suppressants on grain yield, nutrient uptake and moisture-use efficiency on bread wheat (Triticum aestivum)

    International Nuclear Information System (INIS)

    Dash, D.K.; Sen, Avijit; Misra, N.M.

    1988-01-01

    A field trial was conducted on 'Malaviya 37' bread wheat (Triticum aestivum Linn. emend. Fiori and Paol.) in 1982-83 and 1983-84. It included 4 dos es of gamma irradiation of seeds (0, 2.5, 4.5 and 6.5 kR) and 5 treatments of evaporation retardants and transpiration suppressants, viz. control, rice (Oryza sativa Linn.) straw, wheat straw, rice straw + phenyl mercuric acetate (150 ppm) and wheat straw + kaolin (6 per cent). Seed irradiation with gamma-rays at 6.5 kR and wheat straw + kaolin gave 11.76 and 61.37 per cent higher yield than the control respectively. For moisture-use efficiency and NPK uptake these treatments also showed the same trend. (author). 12 refs

  2. ISPA - a high accuracy X-ray and gamma camera Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    ISPA offers ... Ten times better resolution than Anger cameras High efficiency single gamma counting Noise reduction by sensitivity to gamma energy ...for Single Photon Emission Computed Tomography (SPECT)

  3. Found: A Galaxy's Missing Gamma Rays

    Science.gov (United States)

    Kohler, Susanna

    2016-04-01

    Recent reanalysis of data from the Fermi Gamma-ray Space Telescope has resulted in the first detection of high-energy gamma rays emitted from a nearby galaxy. This discovery reveals more about how supernovae interact with their environments.Colliding Supernova RemnantAfter a stellar explosion, the supernovas ejecta expand, eventually encountering the ambient interstellar medium. According to models, this generates a strong shock, and a fraction of the kinetic energy of the ejecta is transferred into cosmic rays high-energy radiation composed primarily of protons and atomic nuclei. Much is still unknown about this process, however. One open question is: what fraction of the supernovas explosion power goes into accelerating these cosmic rays?In theory, one way to answer this is by looking for gamma rays. In a starburst galaxy, the collision of the supernova-accelerated cosmic rays with the dense interstellar medium is predicted to produce high-energy gamma rays. That radiation should then escape the galaxy and be visible to us.Pass 8 to the RescueObservational tests of this model, however, have beenstumped by Arp 220. This nearby ultraluminous infrared galaxy is the product of a galaxy merger ~700 million years ago that fueled a frenzy of starbirth. Due to its dusty interior and extreme levels of star formation, Arp 220 has long been predicted to emit the gamma rays produced by supernova-accelerated cosmic rays. But though weve looked, gamma-ray emission has never been detected from this galaxy until now.In a recent study, a team of scientists led by Fang-Kun Peng (Nanjing University) reprocessed 7.5 years of Fermi observations using the new Pass 8 analysis software. The resulting increase in resolution revealed the first detection of GeV emission from Arp 220!Acceleration EfficiencyGamma-ray luminosity vs. total infrared luminosity for LAT-detected star-forming galaxies and Seyferts. Arp 220s luminosities are consistent with the scaling relation. [Peng et al. 2016

  4. Carbamazepine degradation by gamma irradiation coupled to biological treatment

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shizong [Collaborative Innovation Center for Advanced Nuclear Energy Technology, INET, Tsinghua University, Beijing 100084 (China); Wang, Jianlong, E-mail: wangjl@tsinghua.edu.cn [Collaborative Innovation Center for Advanced Nuclear Energy Technology, INET, Tsinghua University, Beijing 100084 (China); Beijing Key Laboratory of Radioactive Wastes Treatment, Tsinghua University, Beijing 100084 (China)

    2017-01-05

    Highlights: • Carbamazepine was removed by the combined gamma radiation and biodegradation. • The removal efficiency of carbamazepine increased with dose. • Irradiation could enhance the mineralization of carbamazepine significantly. • The combined irradiation and biodegradation was effective for carbamazepine removal. - Abstract: Carbamazepine is an emerging contaminant and resistant to biodegradation, which cannot be effectively removed by the conventional biological wastewater treatment processes. In this study, the combined gamma irradiation and biodegradation was employed to remove carbamazepine from wastewater. The effect of dose on the removal of carbamazepine was studied at different doses (300, 600 and 800 Gy). The results showed that the removal efficiency of carbamazepine increased with dose increasing during the irradiation process. The maximum removal efficiency was 99.8% at 800 Gy, while the removal efficiency of total organic carbon (TOC) was only 26.5%. The removal efficiency of TOC increased to 79.3% after the sequent biological treatment. In addition, several intermediates and organic acids were detected. The possible degradation pathway of carbamazepine during the integrated irradiation and biodegradation was proposed. Based on the overall analysis, the combined gamma irradiation and biological treatment process can be an alternative for removing the recalcitrant organic pollutants such as carbamazepine from wastewater.

  5. Cytochrome C effect on gamma-ray efficiency on barley seeds at different metabolic states

    International Nuclear Information System (INIS)

    Yankulov, M.

    1981-01-01

    Radiobiological studies of the effect of gamma-rays on the barley seeds were performed. It was shown that the different metabolic states of the seeds do not modify the effect of the independent treatment with cytochrome C, while the action of the gamma-rays is markedly modified. With the increase in the preliminary seed soaking time in H 2 O, the total lethality in the case of irradiated treatments rises from 54.10% to 91.00% and that of sterility to 13.13 and 57.44% for 12 and 72 hrs, respectively. The preliminary and post-irradiation treatment of seeds with cytochrome C markedly reduces the effect of gamma-rays, calculated by the criteria of general lethality and sterility, the trend towards an increase in the sensitivity with the increase in the extention of the preliminary soaking time of seeds in water being preserved. Preliminary soaking in the seeds in water also modifies the mutagenic effect of gamma-rays to a considerable extent. (author)

  6. Track finding in gamma conversions in CMS

    CERN Document Server

    INSPIRE-00104750

    2008-01-01

    A track finding algorithm has been developed for reconstruction of e+e- pairs. It combines the information of the electromagnetic calorimeter with the information provided by the Tracker. Results on reconstruction efficiency of converted photons, as well as on fake rate are shown for single isolated photons and for photons from H->gamma gamma events with pile-up events at 10^33 cm^-2 s^-1 LHC luminosity.

  7. Neutron-gamma discrimination of boron loaded plastic scintillator

    International Nuclear Information System (INIS)

    Wang Dong; He Bin; Zhang Quanhu; Wu Chuangxin; Luo Zhonghui

    2010-01-01

    Boron loaded plastic scintillator could detect both fast neutrons thanks to hydrogen and thermal neutrons thanks to 10B. Both reactions have large cross sections, and results in high detection efficiency of incident neutrons. However, similar with other organic scintillators, boron loaded plastic scintillator is sensitive to gamma rays and neutrons. So gamma rays must be rejected from neutrons using their different behavior in the scintillator. In the present research zero crossing method was used to test neutron-gamma discrimination of BC454 boron loaded plastic scintillator. There are three Gaussian peaks in the time spectrum, they are corresponding to gamma rays, fast neutrons and flow neutrons respectively. Conclusion could be made that BC454 could clear discriminate slow neutrons and gamma, but the discrimination performance turns poor as the neutrons' energy becomes larger. (authors)

  8. Can a canopy temperature-based stress index enhance water use efficiency in irrigated wine grape under arid conditions?

    Science.gov (United States)

    Enhancement of irrigation water use efficiency and water productivity in arid wine grape production regions is hindered by a lack of automated, real-time methods for monitoring and interpreting vine water status. A normalized, water stress index calculated from real-time vine canopy temperature meas...

  9. TPASS: a gamma-ray spectrum analysis and isotope identification computer code

    International Nuclear Information System (INIS)

    Dickens, J.K.

    1981-03-01

    The gamma-ray spectral data-reduction and analysis computer code TPASS is described. This computer code is used to analyze complex Ge(Li) gamma-ray spectra to obtain peak areas corrected for detector efficiencies, from which are determined gamma-ray yields. These yields are compared with an isotope gamma-ray data file to determine the contributions to the observed spectrum from decay of specific radionuclides. A complete FORTRAN listing of the code and a complex test case are given

  10. Synthesis of Pt-Ru PSB-Py catalysis by {gamma}-irradiation and their electrocatalytic efficiency for methanol oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Ah; Sim, Kwang Sik; Choi, Seong Ho [Hannam University, Daejeon (Korea, Republic of); Jung, Sung Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-09-15

    We report here that deposition of Pt-Ru catalysis on the surface of core-shell conductive balls by radiation-chemical reduction of Pt and Ru ions, in order to use as catalysis in a fuel cell. The poly(styrene-co-4-vinylphenylboronic acid)-pyrrole (PSB-Py) with core-shell structure was obtained by in situ polymerization of pyrrole in the presence of the poly(styrene-co-4-vinylphenylboronic acid) (PSB). Subsequently, Pt-Ru catalysis were deposited onto PSB-Py ball by {gamma}-irradiation, in the presence/absence of poly(vinypyrolidone) (PVP) to prepare electrocatalysis for a fuel cell. The catalytic efficiency of Pt-Ru PSB-Py catalyst was examined for carbon monoxide (CO) stripping and methanol oxidation.

  11. Uranium, radium and thorium in soils with high-resolution gamma spectroscopy, MCNP-generated efficiencies, and VRF non-linear full-spectrum nuclide shape fitting

    Directory of Open Access Journals (Sweden)

    Metzger Robert

    2017-01-01

    Full Text Available A new method for analysis of uranium and radium in soils by gamma spectroscopy has been developed using VRF (“Visual RobFit” which, unlike traditional peak-search techniques, fits full-spectrum nuclide shapes with non-linear least-squares minimization of the chi-squared statistic. Gamma efficiency curves were developed for a 500 mL Marinelli beaker geometry as a function of soil density using MCNP. Collected spectra were then analyzed using the MCNP-generated efficiency curves and VRF to deconvolute the 90 keV peak complex of uranium and obtain 238U and 235U activities. 226Ra activity was determined either from the radon daughters if the equilibrium status is known, or directly from the deconvoluted 186 keV line. 228Ra values were determined from the 228Ac daughter activity. The method was validated by analysis of radium, thorium and uranium soil standards and by inter-comparison with other methods for radium in soils. The method allows for a rapid determination of whether a sample has been impacted by a man-made activity by comparison of the uranium and radium concentrations to those that would be expected from a natural equilibrium state.

  12. Uranium, radium and thorium in soils with high-resolution gamma spectroscopy, MCNP-generated efficiencies, and VRF non-linear full-spectrum nuclide shape fitting

    Science.gov (United States)

    Metzger, Robert; Riper, Kenneth Van; Lasche, George

    2017-09-01

    A new method for analysis of uranium and radium in soils by gamma spectroscopy has been developed using VRF ("Visual RobFit") which, unlike traditional peak-search techniques, fits full-spectrum nuclide shapes with non-linear least-squares minimization of the chi-squared statistic. Gamma efficiency curves were developed for a 500 mL Marinelli beaker geometry as a function of soil density using MCNP. Collected spectra were then analyzed using the MCNP-generated efficiency curves and VRF to deconvolute the 90 keV peak complex of uranium and obtain 238U and 235U activities. 226Ra activity was determined either from the radon daughters if the equilibrium status is known, or directly from the deconvoluted 186 keV line. 228Ra values were determined from the 228Ac daughter activity. The method was validated by analysis of radium, thorium and uranium soil standards and by inter-comparison with other methods for radium in soils. The method allows for a rapid determination of whether a sample has been impacted by a man-made activity by comparison of the uranium and radium concentrations to those that would be expected from a natural equilibrium state.

  13. Real time gamma-ray signature identifier

    Science.gov (United States)

    Rowland, Mark [Alamo, CA; Gosnell, Tom B [Moraga, CA; Ham, Cheryl [Livermore, CA; Perkins, Dwight [Livermore, CA; Wong, James [Dublin, CA

    2012-05-15

    A real time gamma-ray signature/source identification method and system using principal components analysis (PCA) for transforming and substantially reducing one or more comprehensive spectral libraries of nuclear materials types and configurations into a corresponding concise representation/signature(s) representing and indexing each individual predetermined spectrum in principal component (PC) space, wherein an unknown gamma-ray signature may be compared against the representative signature to find a match or at least characterize the unknown signature from among all the entries in the library with a single regression or simple projection into the PC space, so as to substantially reduce processing time and computing resources and enable real-time characterization and/or identification.

  14. A study on operation efficiency evaluation based on firm's financial index and benchmark selection: take China Unicom as an example

    Science.gov (United States)

    Wu, Zu-guang; Tian, Zhan-jun; Liu, Hui; Huang, Rui; Zhu, Guo-hua

    2009-07-01

    Being the only listed telecom operators of A share market, China Unicom has always been attracted many institutional investors under the concept of 3G recent years,which itself is a great technical progress expectation.Do the institutional investors or the concept of technical progress have signficant effect on the improving of firm's operating efficiency?Though reviewing the documentary about operating efficiency we find that schoolars study this problem useing the regress analyzing based on traditional production function and data envelopment analysis(DEA) and financial index anayzing and marginal function and capital labor ratio coefficient etc. All the methods mainly based on macrodata. This paper we use the micro-data of company to evaluate the operating efficiency.Using factor analyzing based on financial index and comparing the factor score of three years from 2005 to 2007, we find that China Unicom's operating efficiency is under the averge level of benchmark corporates and has't improved under the concept of 3G from 2005 to 2007.In other words,institutional investor or the conception of technical progress expectation have faint effect on the changes of China Unicom's operating efficiency. Selecting benchmark corporates as post to evaluate the operating efficiency is a characteristic of this method ,which is basicallly sipmly and direct.This method is suit for the operation efficiency evaluation of agriculture listed companies because agriculture listed also face technical progress and marketing concept such as tax-free etc.

  15. Studies of weak capture-gamma-ray resonances via coincidence techniques

    CERN Document Server

    Rowland, C; Champagne, A E; Dummer, A K; Fitzgerald, R; Harley, E C T; Mosher, J; Runkle, R

    2002-01-01

    A method for measuring weak capture-gamma-ray resonances via gamma gamma-coincidence counting techniques is described. The coincidence apparatus consisted of a large-volume germanium detector and an annular NaI(Tl) crystal. The setup was tested by measuring the weak E sub R =227 keV resonance in sup 2 sup 6 Mg(p,gamma) sup 2 sup 7 Al. Absolute germanium and NaI(Tl) counting efficiencies for a range of gamma-ray energies and for different detector-target geometries are presented. Studies of the gamma-ray background in our spectra are described. Compared to previous work, our method improves the detection sensitivity for weak capture-gamma-ray resonances by a factor of approx 100. The usefulness of the present technique for investigations of interest to nuclear astrophysics is discussed.

  16. Prompt Gamma Ray Spectroscopy for process monitoring

    International Nuclear Information System (INIS)

    Zoller, W.H.; Holmes, J.L.

    1991-01-01

    Prompt Gamma Ray Spectroscopy (PGRS) is a very powerful analytical technique able to measure many metallic, contamination problem elements. The technique involves measurement of gamma rays that are emitted by nuclei upon capturing a neutron. This method is sensitive not only to the target element but also to the particular isotope of that element. PGRS is capable of measuring dissolved metal ions in a flowing system. In the field, isotopic neutron sources are used to produce the desired neutron flux ( 252 Cf can produce neutron flux of the order of 10 8 neutrons/cm 2 --sec.). Due to high penetrating power of gamma radiation, high efficiency gamma ray detectors can be placed in an appropriate geometry to maximize sensitivity, providing real-time monitoring with low detection level capabilities

  17. Gamma radiation effect study in polycarbonate optical and mechanics properties

    International Nuclear Information System (INIS)

    Araujo, E.S. de.

    1991-02-01

    Polycarbonates (PC) are used in different industrial applications due to their excellent dielectric characteristics, impact resistance, and high temperature resistance. In some of these applications, the polycarbonates are exposed to gamma radiation which produces molecular scissions, causing changes in the polycarbonate properties. To estimate the radiation effects in the Durolon polycarbonate, samples were irradiated with 60 Co gamma rays with doses between 0,2 kGy and 300 kGy. The results obtained showed that the PC mechanical properties are not changed due to the gamma radiation. However the results showed an expressive variation in the yellowness index for doses above 1 kGy. The results showed that it is possible to use the gamma sterilization of PC in applications where the coloration of PC is not critical. (author). 21 refs, 25 figs, 3 tabs

  18. Characteristics of a gamma telescope on the ''Kosmos-561'' satellite

    International Nuclear Information System (INIS)

    Bokov, V.L.; Kruglov, E.M.

    1981-01-01

    The results of calculations of gamma telescope characteristics intended for investigating cosmic γ radiation at E>=100 MeV in the ''Cosmos 561'' artificial Earth satellite, using the Monte Carlo method, are presented. The gamma spectrometer contains a lead converter, scintillation deteectors of polysterene, a unit of spark chambers and a Cherenkov detector of lead glass. The dependence of the device effective area and angular resolution on γ quanta energy is calculated. The relative radiation pattern of the device is given. The given integral characteristics of the gamma telescope for a γ quanta flux with an exponential spectrum are the following: the effective geometrical factor and effective device area depending on the spectrum index. The calibration gamma telescope curve is plotted according to the electron mean free path distribution [ru

  19. Terrestrial gamma-ray flashes

    Science.gov (United States)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-08-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models.

  20. Terrestrial gamma-ray flashes

    International Nuclear Information System (INIS)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-01-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models

  1. Standardization of low energy beta and beta-gamma complex emitters by the tracer and the efficiency extrapolation methods

    International Nuclear Information System (INIS)

    Sahagia, M.

    1978-01-01

    The absolute standardization of radioactive solutions of low energy beta emitters and beta-gamma emitters with a high probability of disintegration to the ground state is described; the tracer and the efficiency extrapolation methods were used. Both types of radionuclides were mathematically and physically treated in an unified manner. The theoretical relations between different beta spectra were calculated according to Williams' model and experimentally verified for: 35 S + 60 Co, 35 S + 95 Nb, 147 Pm + 60 Co, 14 C + 95 Nb and two beta branches of 99 Mo. The optimum range of beta efficiency variation was indicated. The basic supposition that all beta efficieny tend to unity in the same time was experimentally verified, using two 192 Ir beta branches. Four computer programs, written in the FORTRAN IV language, were elaborated, for the adequate processing of the experimental data. Good precision coefficients according to international standards were obtained in the absolute standardization of 35 S, 147 Pm, 99 Mo solutions. (author)

  2. Monte Carlo efficiency calibration of a neutron generator-based total-body irradiator

    International Nuclear Information System (INIS)

    Shypailo, R.J.; Ellis, K.J.

    2009-01-01

    Many body composition measurement systems are calibrated against a single-sized reference phantom. Prompt-gamma neutron activation (PGNA) provides the only direct measure of total body nitrogen (TBN), an index of the body's lean tissue mass. In PGNA systems, body size influences neutron flux attenuation, induced gamma signal distribution, and counting efficiency. Thus, calibration based on a single-sized phantom could result in inaccurate TBN values. We used Monte Carlo simulations (MCNP-5; Los Alamos National Laboratory) in order to map a system's response to the range of body weights (65-160 kg) and body fat distributions (25-60%) in obese humans. Calibration curves were constructed to derive body-size correction factors relative to a standard reference phantom, providing customized adjustments to account for differences in body habitus of obese adults. The use of MCNP-generated calibration curves should allow for a better estimate of the true changes in lean tissue mass that many occur during intervention programs focused only on weight loss. (author)

  3. Search for very-high-energy emission from Gamma-ray Bursts using the first 18 months of data from the HAWC Gamma-ray Observatory

    OpenAIRE

    The HAWC collaboration; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Rojas, D. Avila; Solares, H. A. Ayala; Barber, A. S.; Bautista-Elivar, N.; Becerril, A.; Belmont-Moreno, E.; BenZvi, S. Y.; Bernal, A.; Braun, J.

    2017-01-01

    The High Altitude Water Cherenkov (HAWC) Gamma-ray Observatory is an extensive air shower detector operating in central Mexico, which has recently completed its first two years of full operations. If for a burst like GRB 130427A at a redshift of 0.34 and a high-energy component following a power law with index -1.66, the high-energy component is extended to higher energies with no cut-off other than from extragalactic background light attenuation, HAWC would observe gamma rays with a peak ene...

  4. Gamma-Ray Pulsars: Beaming Evolution, Stats and Unident. EGRET Sources

    OpenAIRE

    Yadigaroglu, I. -A.; Romani, Roger W.

    1994-01-01

    We compute the variation of the beaming fraction with the efficiency of high energy gamma-ray production in the outer gap pulsar model of Romani and Yadigaroglu. This allows us to correct the fluxes observed for pulsars in the EGRET band and to derive a simple estimate of the variation of efficiency with age. Integration of this model over the population of young neutron stars gives the expected number of gamma-ray pulsars along with their distributions in age and distance. This model also sh...

  5. SPECTRAL ANALYSIS AND INTERPRETATION OF THE {gamma}-RAY EMISSION FROM THE STARBURST GALAXY NGC 253

    Energy Technology Data Exchange (ETDEWEB)

    Abramowski, A. [Institut fuer Experimentalphysik, Universitaet Hamburg, Luruper Chaussee 149, D-22761 Hamburg (Germany); Acero, F. [Laboratoire Univers et Particules de Montpellier, Universite Montpellier 2, CNRS/IN2P3, CC 72, Place Eugene Bataillon, F-34095 Montpellier Cedex 5 (France); Aharonian, F.; Bernloehr, K.; Bochow, A. [Max-Planck-Institut fuer Kernphysik, P.O. Box 103980, D-69029 Heidelberg (Germany); Akhperjanian, A. G. [National Academy of Sciences of the Republic of Armenia, Yerevan (Armenia); Anton, G.; Balzer, A.; Brucker, J. [Physikalisches Institut, Universitaet Erlangen-Nuernberg, Erwin-Rommel-Str. 1, D-91058 Erlangen (Germany); Barnacka, A. [Nicolaus Copernicus Astronomical Center, ul. Bartycka 18, 00-716 Warsaw (Poland); Becherini, Y. [APC, AstroParticule et Cosmologie, Universite Paris Diderot, CNRS/IN2P3, CEA/lrfu, Observatoire de Paris, Sorbonne Paris Cite, 10, rue Alice Domon et Leonie Duquet, F-75205 Paris Cedex 13 (France); Becker, J. [Institut fuer Theoretische Physik, Lehrstuhl IV: Weltraum und Astrophysik, Ruhr-Universitaet Bochum, D-44780 Bochum (Germany); Birsin, E. [Institut fuer Physik, Humboldt-Universitaet zu Berlin, Newtonstr. 15, D-12489 Berlin (Germany); Biteau, J.; Brun, F. [Laboratoire Leprince-Ringuet, Ecole Polytechnique, CNRS/IN2P3, F-91128 Palaiseau (France); Boisson, C. [LUTH, Observatoire de Paris, CNRS, Universite Paris Diderot, 5 Place Jules Janssen, F-92190 Meudon (France); Bolmont, J. [LPNHE, Universite Pierre et Marie Curie Paris 6, Universite Denis Diderot Paris 7, CNRS/IN2P3, 4 Place Jussieu, F-75252, Paris Cedex 5 (France); Bordas, P. [Institut fuer Astronomie und Astrophysik, Universitaet Tuebingen, Sand 1, D-72076 Tuebingen (Germany); Brun, P. [CEA Saclay, DSM/IRFU, F-91191 Gif-Sur-Yvette Cedex (France); Bulik, T., E-mail: stefan.ohm@le.ac.uk [Astronomical Observatory, The University of Warsaw, Al. Ujazdowskie 4, 00-478 Warsaw (Poland); Collaboration: H.E.S.S. Collaboration; and others

    2012-10-01

    Very high energy (VHE; E {>=} 100 GeV) and high-energy (HE; 100 MeV {<=} E {<=} 100 GeV) data from {gamma}-ray observations performed with the H.E.S.S. telescope array and the Fermi-LAT instrument, respectively, are analyzed in order to investigate the non-thermal processes in the starburst galaxy NGC 253. The VHE {gamma}-ray data can be described by a power law in energy with differential photon index {Gamma} = 2.14 {+-} 0.18{sub stat} {+-} 0.30{sub sys} and differential flux normalization at 1 TeV of F{sub 0} = (9.6 {+-} 1.5{sub stat}(+ 5.7, -2.9){sub sys}) Multiplication-Sign 10{sup -14} TeV{sup -1} cm{sup -2} s{sup -1}. A power-law fit to the differential HE {gamma}-ray spectrum reveals a photon index of {Gamma} 2.24 {+-} 0.14{sub stat} {+-} 0.03{sub sys} and an integral flux between 200 MeV and 200 GeV of F(0.2-200 GeV) = (4.9 {+-} 1.0{sub stat} {+-} 0.3{sub sys}) Multiplication-Sign 10{sup -9} cm{sup -2} s{sup -1}. No evidence for a spectral break or turnover is found over the dynamic range of both the LAT instrument and the H.E.S.S. experiment: a combined fit of a power law to the HE and VHE {gamma}-ray data results in a differential photon index {Gamma} = 2.34 {+-} 0.03 with a p-value of 30%. The {gamma}-ray observations indicate that at least about 20% of the energy of the cosmic rays (CRs) capable of producing hadronic interactions is channeled into pion production. The smooth alignment between the spectra in the HE and VHE {gamma}-ray domain suggests that the same transport processes dominate in the entire energy range. Advection is most likely responsible for charged particle removal from the starburst nucleus from GeV to multiple TeV energies. In a hadronic scenario for the {gamma}-ray production, the single overall power-law spectrum observed would therefore correspond to the mean energy spectrum produced by the ensemble of CR sources in the starburst region.

  6. A study on the performance evaluation of small gamma camera collimators using detective quantun efficiency

    International Nuclear Information System (INIS)

    Jeon, Ho Sang

    2008-02-01

    The anger-type gamma camera and novel marker compound using Tc-99m were firstly introduced in 1963. The gamma camera systems have being improved and applied to various fields, for example, medical, industrial, and environmental fields. Gamma camera is mainly composed of collimator, detector, and signal processor. And the radiative source is namely the imaging object. The collimator is essential component of gamma camera system because the imaging performance of system is mainly dependent on the collimator. The performance evaluation of collimators can be done by using evaluating factors. In this study, the novel factors for gamma camera evaluation are suggested. The established evaluating factors by NEMA are FWHM, sensitivity, and uniformity. They have some limitations in spite of their usefulness. Firstly, performance evaluation by those factors give insensitive and indirect results only. Secondly, the evaluation of noise property is ambiguous. Thirdly, there is no synthetic evaluation of system performance. Simulation with Monte Carlo code and experiment with a small camera camera were simultaenuously performed to verify novel evaluating factors. For the evaluation of spatial resolution, MTF was applied instead of FWHM. The MTF values presents excellent linear relationship with FWHM values. The NNPS was applied instead of uniformity and sensitivity for the evaluation of noise fluctuation. The NNPS values also presents linear relationship with sensitivity and unifomity. Moreover, these novel factors give quantities as the function of spatial frequencies. Finally, the DQE values were given by calculations with MTF, NNPS, and input SNR. DQE effectively presents the synthetic evaluation of gamma camera performance. It is the conclusion that MTF, NNPS, and DQE can be novel evaluating factors for gamma camera systems and the new factor for synthetic evaluation is derived

  7. Cosmic gamma-ray burst

    International Nuclear Information System (INIS)

    Yamagami, Takamasa

    1985-01-01

    Ballon experiments for searching gamma-ray burst were carried out by employing rotating-cross modulation collimators. From a very long observation of total 315 hours during 1975 to 1979, three gamma-ray intensity anomalies were observed which were speculated as a gamma-ray burst. As for the first gamma-ray intensity anomaly observed in 1975, the burst source could be located precisely but the source, heavenly body, could not be specified. Gamma-ray burst source estimation was made by analyzing distribution of burst source in the celestial sphere, burst size distribution, and burst peak. Using the above-mentioned data together with previously published ones, apparent inconsistency was found between the observed results and the adopted theory that the source was in the Galaxy, and this inconsistency was found due to the different time profiles of the burst observed with instruments of different efficiency. It was concluded by these analysis results that employment of logN - logP (relation between burst frequency and burst count) was better than that of logN - logS (burst size) in the examination of gamma-ray burst because the former was less uncertain than the latter. Analyzing the author's observed gamma-ray burst data and the related published data, it was clarified that the burst distribution was almost P -312 for the burst peak value larger than 10 -6 erg/cm 2 .sec. The author could indicate that the calculated celestial distribution of burst source was consistent with the observed results by the derivation using the logN - logP relationship and that the burst larger than 10 -6 erg/cm 2 .sec happens about one thousand times a year, about ten times of the previous value. (Takagi, S.)

  8. Contribution to gamma ray transport calculation in heterogeneous media

    International Nuclear Information System (INIS)

    Bourdet, L.

    1985-04-01

    This thesis presents the development of gamma transport calculation codes in three dimension heterogeneous geometries. These codes allow us to define the protection against gamma-rays or verify their efficiency. The laws that govern the interactions of gamma-rays with matters are briefly revised. A library with the all necessary constants for these codes is created. TRIPOLI-2, a code that treats in exact way the neutron transport in matters using Monte-Carlo method, has been adapted to deal with the transport of gamma-rays in matters as well. TRINISHI, a code which considers only one collision, has been realized to treat heterogeneous geometries containing voids. Elaborating a formula that calculates the albedo for gamma-ray reflection (the code ALBANE) allows us to solve the problem of gamma-ray reflection on plane surfaces. NARCISSE-2 deals with gamma-rays that suffer only one reflection on the inner walls of any closed volume (rooms, halls...) [fr

  9. Livestock wastewater treatment by zeolite ion exchange and gamma-ray irradiation

    International Nuclear Information System (INIS)

    Lee, Sang Ryul; Kim, Tak Hyun; Lee, Myun Joo

    2008-01-01

    Livestock wastewater containing high concentrations of organic matters and ammonia-nitrogen has been known as one of the recalcitrant wastewater. It is difficult to treat by conventional wastewater treatment techniques. This study was carried out to evaluate the feasibility of zeolite ion exchange and gamma-ray irradiation treatment of livestock wastewater. The removal efficiencies of SCOD Cr and NH3-N were significantly enhanced by gamma-ray irradiation after zeolite ion exchange as a pre-treatment. However, the effects of zeolite particle size on the SCOD Cr and NH 3 -N removal efficiencies were insignificant. These results indicate that the combined process of zeolite ion exchange and gamma-ray irradiation has potential for the treatment of livestock wastewater

  10. Improvement effect of gamma-irradiated complex leaf extract of date plum, persimmon and mulberry on UVB-induced skin damage

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Won; Cho, Byoung Ok; Che, Denis Nchang; Shin, Jae Young; Fang, Chong Zhou; Jang, Seon Il [Jeonju University, Jeonju (Korea, Republic of)

    2016-11-15

    This study was conducted to evaluate the improvement effect of gamma-irradiated complex leaf extract of Date Plum, Persimmon and Mulberry (γ-DPME) on UVB induced skin damage. The samples were gamma irradiated at doses of 10 kGy. γ-DPME treatment tended to decrease UVB-induced immune cell infiltration and erthyderma index than the groups treated with non-gamma-irradiated DPME (n-DPME) and L-ascobic acid (AA). In addition, γ-DPME treatment significantly decreased skin thickness, melanin index and mast cell infiltration in UVB-irradiated skin. Moreover, γ-DPME treatment significantly decreased the compound 48/80-induced scratching behavior and immune cell infiltration than n-DPME group. These results show that gamma irradiation can be used to increase the physiological activities of DPME.

  11. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki; Rached, Nadhir B.; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2017-01-01

    the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is related to the difficult question of analyzing the statistics of a sum of Gamma- Gamma random variables

  12. A virtual dosimetry audit - Towards transferability of gamma index analysis between clinical trial QA groups.

    Science.gov (United States)

    Hussein, Mohammad; Clementel, Enrico; Eaton, David J; Greer, Peter B; Haworth, Annette; Ishikura, Satoshi; Kry, Stephen F; Lehmann, Joerg; Lye, Jessica; Monti, Angelo F; Nakamura, Mitsuhiro; Hurkmans, Coen; Clark, Catharine H

    2017-12-01

    Quality assurance (QA) for clinical trials is important. Lack of compliance can affect trial outcome. Clinical trial QA groups have different methods of dose distribution verification and analysis, all with the ultimate aim of ensuring trial compliance. The aim of this study was to gain a better understanding of different processes to inform future dosimetry audit reciprocity. Six clinical trial QA groups participated. Intensity modulated treatment plans were generated for three different cases. A range of 17 virtual 'measurements' were generated by introducing a variety of simulated perturbations (such as MLC position deviations, dose differences, gantry rotation errors, Gaussian noise) to three different treatment plan cases. Participants were blinded to the 'measured' data details. Each group analysed the datasets using their own gamma index (γ) technique and using standardised parameters for passing criteria, lower dose threshold, γ normalisation and global γ. For the same virtual 'measured' datasets, different results were observed using local techniques. For the standardised γ, differences in the percentage of points passing with γ audit has been an informative step in understanding differences in the verification of measured dose distributions between different clinical trial QA groups. This work lays the foundations for audit reciprocity between groups, particularly with more clinical trials being open to international recruitment. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. High resolution gamma spectroscopy well logging system

    International Nuclear Information System (INIS)

    Giles, J.R.; Dooley, K.J.

    1997-01-01

    A Gamma Spectroscopy Logging System (GSLS) has been developed to study sub-surface radionuclide contamination. The absolute counting efficiencies of the GSLS detectors were determined using cylindrical reference sources. More complex borehole geometries were modeled using commercially available shielding software and correction factors were developed based on relative gamma-ray fluence rates. Examination of varying porosity and moisture content showed that as porosity increases, and as the formation saturation ratio decreases, relative gamma-ray fluence rates increase linearly for all energies. Correction factors for iron and water cylindrical shields were found to agree well with correction factors determined during previous studies allowing for the development of correction factors for type-304 stainless steel and low-carbon steel casings. Regression analyses of correction factor data produced equations for determining correction factors applicable to spectral gamma-ray well logs acquired under non-standard borehole conditions

  14. Studies on the true coincidence correction in measuring filter samples by gamma spectrometry

    CERN Document Server

    Lian Qi; Chang Yong Fu; Xia Bing

    2002-01-01

    The true coincidence correction in measuring filter samples has been studied by high efficiency HPGe gamma detectors. The true coincidence correction for a specific three excited levels de-excitation case has been analyzed, and the typical analytical expressions of true coincidence correction factors have been given. According to the measured relative efficiency on the detector surface with 8 'single' energy gamma emitters and efficiency of filter samples, the peak and total efficiency surfaces are fitted. The true coincidence correction factors of sup 6 sup 0 Co and sup 1 sup 5 sup 2 Eu calculated by the efficiency surfaces agree well with experimental results

  15. Characteristics of 3D gamma evaluation according to phantom rotation error and dose gradient

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Hyun; Kim, Dong Su; Kim, Tae Ho; Kang, Seong Hee; Shin, Dong Seok; Noh, Yu Yoon; Suh, Tae Seok [Dept. of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, the Catholic University of Korea, Seoul (Korea, Republic of); Cho, Min Seok [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)

    2016-12-15

    In intensity modulated radiation therapy (IMRT) quality assurance (QA) using dosimetric phantom, a spatial uncertainty induced from phantom set-up inevitably occurs and gamma index that is used to evaluate IMRT plan quality can be affected differently by a combination of the spatial uncertainty and magnitude of dose gradient. In this study, we investigated the impacts of dose gradient and the phantom set-up error on 3D gamma evaluation. In this study, we investigated the characteristics of gamma evaluation according to dose gradient and phantom rotation axis. As a result, 3D gamma had better performance than 2D gamma. Therefore, it can be useful for IMRT QA analysis at clinical field.

  16. Discovery of Pulsations from the Pulsar J0205 6449 in SNR 3C 58 with the Fermi Gamma-Ray Space Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, Aous A.; /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, Marco; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Atwood, William B.; /UC, Santa Cruz; Axelsson, M.; /Stockholm U., OKC /Stockholm U.; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, Guido; /INFN, Trieste /Trieste U.; Bastieri, Denis; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bellazzini, Ronaldo; /INFN, Pisa; Berenji, Bijan; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Blandford, Roger D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bloom, Elliott D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bonamente, E.; /INFN, Perugia /Perugia U.; Borgland, Anders W.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bouvier, A.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bregeon, J.; /INFN, Pisa; Brez, A.; /INFN, Pisa; Brigida, M.; /Bari U. /INFN, Bari /Ecole Polytechnique /Washington U., Seattle /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Columbia U. /IASF, Milan /IASF, Milan /DAPNIA, Saclay /INFN, Perugia /Perugia U. /NASA, Goddard /George Mason U. /Naval Research Lab, Wash., D.C. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /LPCE, Orleans /Montpellier U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /Stockholm U. /Naval Research Lab, Wash., D.C. /INFN, Trieste /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /UC, Santa Cruz /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /CENBG, Gradignan /CENBG, Gradignan /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Manchester U. /Montpellier U. /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; /more authors..

    2011-12-01

    We report the discovery of {gamma}-ray pulsations ({ge}0.1 GeV) from the young radio and X-ray pulsar PSR J0205 + 6449 located in the Galactic supernova remnant 3C 58. Data in the {gamma}-ray band were acquired by the Large Area Telescope aboard the Fermi Gamma-ray Space Telescope (formerly GLAST), while the radio rotational ephemeris used to fold {gamma}-rays was obtained using both the Green Bank Telescope and the Lovell telescope at Jodrell Bank. The light curve consists of two peaks separated by 0.49 {+-} 0.01 {+-} 0.01 cycles which are aligned with the X-ray peaks. The first {gamma}-ray peak trails the radio pulse by 0.08 {+-} 0.01 {+-} 0.01, while its amplitude decreases with increasing energy as for the other {gamma}-ray pulsars. Spectral analysis of the pulsed {gamma}-ray emission suggests a simple power law of index -2.1 {+-} 0.1 {+-} 0.2 with an exponential cutoff at 3.0{sub -0.7}{sup +1.1} {+-} 0.4 GeV. The first uncertainty is statistical and the second is systematic. The integral {gamma}-ray photon flux above 0.1 GeV is (13.7 {+-} 1.4 {+-} 3.0) x 10{sup -8} cm{sup -2} s{sup -1}, which implies for a distance of 3.2 kpc and assuming a broad fan-like beam a luminosity of 8.3 x 10{sup 34} erg s{sup -1} and an efficiency {eta} of 0.3%. Finally, we report a 95% upper limit on the flux of 1.7 x 10{sup -8} cm{sup -2} s{sup -1} for off-pulse emission from the object.

  17. Studies on mutagenic effectiveness and efficiency of gamma rays and its effect on quantitative traits in finger millet (Eleusine coracana L. Gaertn

    Directory of Open Access Journals (Sweden)

    A.R. Ambavane

    2015-01-01

    Full Text Available Dry seeds (12% moisture of two finger millet cultivar viz., Dapoli-1 and Dapoli Safed were irradiated with four doses of gamma-rays viz., 400 Gy, 500 Gy, 600 Gy and 700 Gy at BARC, Mumbai. In laboratory test, root and shoot lengths of seedlings were decreased with increase in dose of gamma rays. Similarly, germination percentage and survival rate of seedlings were decreased with increase in dose of gamma irradiation during field study. In M1 generation, three types of chlorophyll mutations viz., albino, xantha and viridis were observed. Albino and xantha were observed in all treatments, whereas, viridis observed only in lower doses viz., 400 Gy and 500 Gy. Based on the chlorophyll mutation frequency on M1 plants, mutagenic effectiveness and efficiency were computed. In Dapoli-1 variety, two early maturing mutants and three high yielding mutants were isolated from 500 Gy dose and 600 Gy dose, respectively. In M2 generation, the mutagenic treatments were effective in inducing various types of chlorophyll and morphological macro mutants, few of those show significant change in flowering, maturity and plant height character and few of them have good breeding value.

  18. $\\gamma$-$\\gamma$ and $\\gamma$-p events at high energies

    CERN Document Server

    Schuler, Gerhard A.; Gerhard A Schuler; Torbjorn Sjostrand

    1994-01-01

    A real photon has a complicated nature, whereby it may remain unresolved or fluctuate into a vector meson or a perturbative q-qbar pair. Based on this picture, we previously presented a model for gamma-p events that is based on the presence of three main event classes: direct, VMD and anomalous. In gamma-gamma events, a natural generalization gives three-by-three combinations of the nature of the two incoming photons, and thus six distinct event classes. The properties of these classes are constrained by the choices already made, in the gamma-p model, of cut-off procedures and other aspects. It is therefore possible to predict the energy-dependence of the cross section for each of the six components separately. The total cross section thus obtained is in good agreement with data, and also gives support to the idea that a simple factorized ansatz with a pomeron and a reggeon term can be a good approximation. Event properties undergo a logical evolution from p-p to gamma-p to gamma-gamma events, with larger cha...

  19. On calculation of detection efficiency of gamma spectrometers with germanium detection

    International Nuclear Information System (INIS)

    Sima, O.

    2001-01-01

    High resolution gamma spectrometer represents a powerful analysis technique of use in various fields from basic research to the study of environmental radioactivity, from medical investigations to geological surveys. Direct experimental calibration cannot cover the large range of measurement configurations of interest. Actually, it can be appropriately applied in an only limited number of cases, as for instance, in case of point-like sources or liquid phase volume sources. To assist the treatment of experimental calibration of germanium detectors, in the frame of Atomic and Nuclear Physics Chair of Department of Physics, a number of calculation methods were developed. These methods are generally based on Monte Carlo simulation but simplified and fast analytical methods were also worked out. Initially, these studies were dedicated to application in the field of environmental activity and radiation protection, but later on these were extended also to other fields as, for instance, the neutron activation or radionuclide metrology. First, the effects of matrices were calculated for the case of volume sources. Applying the matrix corrections allows obtaining the source calibration curves on the basis of experimental calibration data obtained with liquid sources, in the same geometry. An algorithm based on Monte Carlo calculation and using techniques of correlated selection was obtained. This algorithm can be implemented in the gamma analysis programs giving for the first time the possibility of correct evaluation of matrix effects even during the analysis of gamma spectra. We used a set of additive relations applicable in case of volume sources with negligible self-absorption and obtained a number of linear relations useful in calibrating the large volume sources in presence of self-absorption, based on small volume standard sources. Also, we proposed analytical relations useful in the case of measurements of large volume samples, in case of Marinelli geometry. To

  20. Disinfection and regrowth potential of bacillus subtilis spores by ozone, ultraviolet rays and gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hae Yeon; Lee, O Mi; Kim, Tae Hun; Lee, Myun Joo; Yu, Seung Ho [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2009-06-15

    Chlorination has been the most commonly adopted disinfection process for the treatment of drinking water. However, Cryptosporidium parvum oocysts and Giardia lamblia cysts were not treated effectively by the common chlorine-based disinfectants. Additionally the regrowth of pathogenic microorganisms is associated with hygienic and aesthetic problems for the consumers of drinking water. Study on alternative disinfection processes such as ozone, UV-C, VUV and gamma irradiation were conducted. Bacillus subtilis spores have been used as a surrogate microorganism for Cryptosporidium parvum oocysts and Giardia lamblia cyst. Inactivation efficiency by ozone was from 30% to 96% within the range of 5 min to 120 min exposures. Inactivation efficiencies by UV-C and VUV were 95.18%, 95.07% at 30 sec, respectively. Inactivation efficiency at gamma irradiation dose of 2 kGy was 99.4%. Microbial regrowths after ozone, UV-C, VUV and gamma irradiation disinfections were also evaluated for 4 days. Bacillus subtilis spores after ozone treatment for 120 min exposure at the rate of 1.68 mg {center_dot} min{sup -1} showed 96.02% disinfection efficiency and significant microbial regrowth. Bacillus subtilis spores after UV-C (99.25% disinfection efficiency) and VUV (99.67% disinfection efficiency) treatments for 5 min showed gradual regrowth. However, inactivation efficiency of gamma irradiation at dose of 1 kGy was 98.8% and the disinfected sample showed no microbial regrowth for 4 days. Therefore, gamma irradiation is the most effective process for the disinfection of pathogenic microorganisms such as oocysts of protozoan parasites among four disinfection process.

  1. Disinfection and regrowth potential of bacillus subtilis spores by ozone, ultraviolet rays and gamma irradiation

    International Nuclear Information System (INIS)

    Kim, Hae Yeon; Lee, O Mi; Kim, Tae Hun; Lee, Myun Joo; Yu, Seung Ho

    2009-01-01

    Chlorination has been the most commonly adopted disinfection process for the treatment of drinking water. However, Cryptosporidium parvum oocysts and Giardia lamblia cysts were not treated effectively by the common chlorine-based disinfectants. Additionally the regrowth of pathogenic microorganisms is associated with hygienic and aesthetic problems for the consumers of drinking water. Study on alternative disinfection processes such as ozone, UV-C, VUV and gamma irradiation were conducted. Bacillus subtilis spores have been used as a surrogate microorganism for Cryptosporidium parvum oocysts and Giardia lamblia cyst. Inactivation efficiency by ozone was from 30% to 96% within the range of 5 min to 120 min exposures. Inactivation efficiencies by UV-C and VUV were 95.18%, 95.07% at 30 sec, respectively. Inactivation efficiency at gamma irradiation dose of 2 kGy was 99.4%. Microbial regrowths after ozone, UV-C, VUV and gamma irradiation disinfections were also evaluated for 4 days. Bacillus subtilis spores after ozone treatment for 120 min exposure at the rate of 1.68 mg · min -1 showed 96.02% disinfection efficiency and significant microbial regrowth. Bacillus subtilis spores after UV-C (99.25% disinfection efficiency) and VUV (99.67% disinfection efficiency) treatments for 5 min showed gradual regrowth. However, inactivation efficiency of gamma irradiation at dose of 1 kGy was 98.8% and the disinfected sample showed no microbial regrowth for 4 days. Therefore, gamma irradiation is the most effective process for the disinfection of pathogenic microorganisms such as oocysts of protozoan parasites among four disinfection process

  2. Nanodefect formation in LiF crystals under gamma irradiation

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Ibragimova, Eh.M.; Kalanov, M.U.; Muminov, M.I.

    2006-01-01

    One studied the spectra of absorption and of photoluminescence, microhardness and performed X-ray structure analysis of gamma-irradiated LiF crystals in a shutdown reactor and in 60 Co source when gamma-radiation dose rate was equal to 7.65 Gy/s. In addition to formation of point and combined radiation defects one detected the presence of the gamma-irradiation induced 28 nm size nanoparticles of LiOH phase in Li sublattice. Formation of defects is shown to occur more efficiently in a shutdown reactor in contrast to 60 Co source [ru

  3. Realization of a gamma multiplicity filter and gamma multiplicity measurements

    International Nuclear Information System (INIS)

    Azgui, F.

    1981-12-01

    A gamma multiplicity filter for the study of reaction mechanism has been realised. It's composed of six NaI(Tl) counters. The flexibility of the geometry allows many configurations. This set up has been tested with gamma radioactive sources and with the 252 Cf source to resolve problems of gamma-efficiency of the NaI(Tl) counters and the contamination of neutrons in these detectors. A logical electronic unit (Encodeur) has been constructed and the around electronic has been developped. This gamma multiplicity filter has been coupled with a detector of high resolution Ge(Li), and used in two reactions: 12 C + 55 Mn at E( 12 C) = 54 MeV; α + 63 Cu at E(α) = 52 MeV. The dominant process is the fusion-evaporation. The compound nucleus 67 Ga, is formed at the same excitation energy. The values of multiplicities Msub(γ) have been extracted using a program based on the formalism of W.J. Ockels. The fractionalization of the angular momentum is well observed for some residual nuclei ( 63 Zn, 64 Zn, 65 Zn), and for each residual nucleus, the average gamma multiplicity is lower with projectile α than that with projectile 12 C. For the most strongly output channel p2n, an entry point for the 64 Zn has been determined in the reactions. All these observations are in good agreement with those published, in the same region (f-p shell) of nuclei. This set up can be coupled with different central detector as, ''X'', neutrons charged particles detectors, and will be used with the new machine SARA to make a systematic study of transfer of angular momentum to the fragments at 30 MeV/A [fr

  4. arXiv $\\mathbb R^3$ Index for Four-Dimensional $N=2$ Field Theories

    CERN Document Server

    Alexandrov, Sergei; Neitzke, Andrew; Pioline, Boris

    2015-01-01

    In theories with $N=2$ supersymmetry on $R^{3,1}$, BPS bound states can decay across walls of marginal stability in the space of Coulomb branch parameters, leading to discontinuities in the BPS indices $\\Omega(\\gamma,u)$. We consider a supersymmetric index $I$ which receives contributions from 1/2-BPS states, generalizing the familiar Witten index $Tr (-1)^F e^{-\\beta H}$. We expect $I$ to be smooth away from loci where massless particles appear, thanks to contributions from the continuum of multi-particle states. Taking inspiration from a similar phenomenon in the hypermultiplet moduli space of $N=2$ string vacua, we conjecture a formula expressing $I$ in terms of the BPS indices $\\Omega(\\gamma,u)$, which is continuous across the walls and exhibits the expected contributions from single particle states at large $\\beta$. This gives a universal prediction for the contributions of multi-particle states to the index $I$. This index is naturally a function on the moduli space after reduction on a circle, closely ...

  5. Gamma irradiators for radiation processing

    International Nuclear Information System (INIS)

    2006-01-01

    Radiation technology is one of the most important fields which the IAEA supports and promotes, and has several programmes that facilitate its use in the developing Member States. In view of this mandate, this Booklet on 'Gamma Irradiators for Radiation Processing' is prepared which describes variety of gamma irradiators that can be used for radiation processing applications. It is intended to present description of general principles of design and operation of the gamma irradiators available currently for industrial use. It aims at providing information to industrial end users to familiarise them with the technology, with the hope that the information contained here would assist them in selecting the most optimum irradiator for their needs. Correct selection affects not only the ease of operation but also yields higher efficiency, and thus improved economy. The Booklet is also intended for promoting radiation processing in general to governments and general public

  6. The impact of ownership structure on bank productivity and efficiency: Evidence from semi-parametric Malmquist Productivity Index

    Directory of Open Access Journals (Sweden)

    Fadzlan Sufian

    2014-12-01

    Full Text Available The present study employs the state of the art bias-corrected Malmquist Productivity Index method to examine the sources of efficiency and productivity of the foreign and domestic banks operating in the Malaysian banking sector. The preferred methodology enables us to isolate efforts to catch up to the frontier (efficiency change from shifts in the frontier (technological change [TECHCH]. The results indicate that the Malaysian banking sector has exhibited productivity progress mainly attributed to technological progress. The empirical findings suggest that both the domestic and foreign banks have exhibited productivity progress albeit at different quantum attributed mainly to progress in TECHCH.

  7. Precise measurement of {gamma}(K{yields}e {nu}({gamma}))/{gamma}(K{yields}{mu} {nu}({gamma})) and study of K{yields}e {nu} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, F.; Massarotti, P.; Meola, S.; Napolitano, M. [Dipartimento di Scienze Fisiche dell' Universita ' ' Federico II' ' , Napoli (Italy); INFN Sezione di Napoli, Napoli (Italy); Antonelli, A.; Antonelli, M.; Bencivenni, G.; Bloise, C.; Bossi, F.; Capon, G.; Capussela, T.; Ciambrone, P.; De Lucia, E.; De Simone, P.; Dreucci, M.; Felici, G.; Gatti, C.; Giovannella, S.; Jacewicz, M.; Lanfranchi, G.; Miscetti, S.; Moulson, M.; Murtas, F.; Palutan, M.; Santangelo, P.; Sciascia, B.; Sibidanov, A.; Spadaro, T.; Venanzoni, G. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Archilli, F. [Dipartimento di Fisica dell' Universita ' ' Tor Vergata' ' , Rome (Italy); INFN Sezione di Roma Tor Vergata, Rome (Italy); Beltrame, P.; Denig, A.; Mueller, S. [Johannes Gutenberg-Universitaet, Institut fuer Kernphysik, Mainz (Germany); Bini, C.; De Santis, A.; De Zorzi, G.; Di Domenico, A.; Fiore, S.; Franzini, P.; Gauzzi, P. [Dipartimento di Fisica dell' Universita ' ' La Sapienza' ' , Rome (Italy); INFN Sezione di Roma, Rome (Italy); Bocchetta, S.; Ceradini, F.; Di Micco, B.; Nguyen, F. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); INFN Sezione di Roma Tre, Rome (Italy); Branchini, P.; Graziani, E.; Passeri, A.; Tortora, L. [INFN Sezione di Roma Tre, Rome (Italy); Capriotti, D. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); Di Donato, C. [INFN Sezione di Napoli, Napoli (Italy); Kulikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lee-Franzini, J. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); State University of New York, Physics Department, Stony Brook (United States); Martini, M.; Patera, V.; Versaci, R. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Energetica dell' Universita ' ' La Sapienza' ' , Rome (Italy); Valente, P. [INFN Sezione di Roma, Rome (Italy)

    2009-12-15

    We present a precise measurement of the ratio R{sub K}={gamma}(K{yields}e{nu}({gamma}))/{gamma}(K{yields}{mu}{nu}({gamma})) and a study of the radiative process K{yields}e{nu}{gamma}, performed with the KLOE detector. The results are based on data collected at the Frascati e{sup +}e{sup -} collider DA {phi}NE for an integrated luminosity of 2.2 fb{sup -1}. We find R{sub K}=(2.493{+-}0.025{sub stat}{+-}0.019{sub syst}) x 10{sup -5}, in agreement with the Standard Model expectation. This result is used to improve constraints on parameters of the Minimal Supersymmetric Standard Model with lepton flavor violation. We also measured the differential decay rate d {gamma}(K{yields}e{nu}{gamma})/dE{sub {gamma}} for photon energies 10gamma}}<250 MeV. Results are compared with predictions from theory. (orig.)

  8. Characterization of Compton-suppressed TIGRESS detectors for high energy gamma-rays

    International Nuclear Information System (INIS)

    Kshetri, R.; Andreoiu, C.; Cross, D.S.; Galinski, N.; Ball, G.C.; Djongolov, M.; Garnsworthy, A.B.; Hackman, G.; Orce, J.N.; Pearson, C.; Triambak, S.; Williams, S.J.; Drake, T.; Smalley, D.; Svensson, C.E.

    2009-01-01

    The TRIUMF-ISAC Gamma-Ray Escape- Suppressed Spectrometer (TIGRESS) will consist of 12 large-volume, 32-fold segmented HPGe clover detectors. Each detector is shielded by a 20-fold segmented Compton suppression shield. For performing discrete gamma-ray spectroscopy of light mass nuclei with TIGRESS, we need information about full energy peak efficiency, resolution and lineshape of full energy peaks for high energy gamma-rays. However, suitable radioactive sources having decay gamma-rays of energies greater than ∼ 3.5 MeV are not easily available. So the characteristics of gamma spectrometers at energies higher than 3.5 MeV are usually determined from simulation data. Predictions from GEANT4 simulations (experimentally validated from 0.3 to 3 MeV) indicate that TIGRESS will be capable for single 10 MeV gamma-rays of absolute detection efficiency of 1.5% for backward configuration of the array. It has been observed experimentally that simulation results work well up to certain energies and might deviate at higher energies. So, it is essential to check the validity of simulation results for energies above 3.3 MeV. We have investigated the high energy performance of seven TIGRESS detectors up to 8 MeV

  9. Effect of gamma radiation on wheat plant growth due to impact on gas exchange characteristics and mineral nutrient uptake and utilization

    International Nuclear Information System (INIS)

    Bhupinder Singh; Sumedha Ahuja; Singhal, R.K.; Venu Babu, P.

    2013-01-01

    The experiment was conducted to determine the effect of gamma radiation on plant growth and development, flag leaf gas exchange characteristics such as net photosynthetic rate (P N ), stomatal conductance (g s ), and transpiration rate (E) and activity of key carbon and nitrogen assimilating enzymes like Rubisco, starch synthase (SS) and nitrate reductase (NR) in field grown wheat. Grains of cultivar PBW-343 were exposed to a 60 Co (Cobalt-60) gamma source at a dose range from 0 to 500 Gy (Gray). Gas exchange characteristics of flag leaf were measured using Infrared Gas Analyzer (IRGA), while mineral nutrients were analyzed spectrophotometrically. Our results show that an irradiation treatment, in general, caused an improvement in plant growth and yield characteristics such as shoot and root mass, root length and surface area, leaf area and chlorophyll SPAD index, tiller number and grain yield. However, irradiation exceeding 5 Gy reduced the magnitude of radiation advantage for most of the investigated physiological and biochemical traits. No germination was recorded at 500 Gy irradiation dose. A dose-dependant increase in shoot Fe in radiated plants up to 25 Gy reflected its higher plant root to shoot translocation which may yield micronutrient rich grains. At higher dose of 100 Gy, there was a drastic reduction in flag leaf membrane stability index (MSI), photosynthesis, Rubisco, NR, and nutrients like K, P, Mg, Fe, and Zn. Starch synthase enzyme activity was unaffected by gamma irradiation indicating that the negative effect of high dose (100 Gy) on the grain yield were caused by the adverse effect of radiation on the gas exchange attributes particularly photosynthesis, carbon, and nitrogen assimilation efficiency and the plant uptake of mineral nutrients. The study concludes that gamma radiation at a low dose (25 Gy or lower) stimulates, while a high dose (100 Gy and above) inhibits plant growth and development of wheat. The adverse effect at 100 Gy and beyond

  10. DNA-repair after irradiation of cells with gamma-rays and neutrons

    International Nuclear Information System (INIS)

    Altmann, H.

    1975-11-01

    The structural alterations of calf thymus DNA produced by neutron or gamma irradiation were observed by absorption spectra, sedimentation rate and viscosity measurements. Mixed neutron-gamma irradiation produced fewer single and double strand breaks compared with pure gamma irradiation. RBE-values for mixed neutron-gamma radiation were less than 1, and DNA damage decreased with increasing neutron dose rate. Repair processes of DNA occuring after irradiation were measured in mouse spleen suspensions and human lymphocytes using autoradiographic methods and gradient centrifugations. The number of labelled cells was smaller after mixed neutron-gamma irradiation than after gamma irradiation. The rejoining of strand breaks in alkaline and neutral sucrose was more efficient after gamma irradiation than after mixed neutron-gamma irradiation. Finally, the effect of detergents Tween 80 and Nonident P40 on unscheduled DNA synthesis was studied by autoradiography after mixed neutron-gamma irradiation (Dn=5 krad). The results showed that the DNA synthesis was inhibited by detergent solutions of 0.002%

  11. Gamma irradiation effects on the thermal, optical and structural properties of Cr-39 nuclear track detector

    International Nuclear Information System (INIS)

    Nouh, S.A.; Said, A.F.; Atta, M.R.; EL-Mellegy, W.M.; EL-Meniawi, S.

    2006-01-01

    A study of the effect of gamma irradiation on the thermal, optical and structural properties of CR-39 diglycol carbonate solid state nuclear track detector (SSNTD) has been carried out. Samples from CR-39 polymer were irradiated with gamma doses at levels between 20 and 300 KGy. Non-isothermal studies were carried out using thermo-gravimetry (TG), differential thermo-gravimetry (DTG) and differential thermal analysis (DTA) to obtain the activation energy of decomposition and the transition temperatures for the non-irradiated and irradiated CR-39 samples. In addition, optical and structural property studies were performed on non-irradiated and irradiated CR-39 samples using refractive index and X-ray diffraction measurements. The variation of onset temperature of decomposition (To) thermal activation energy of decomposition (Ea) melting temperature (Tm) refractive index (n) and the mass fraction of the amorphous phase with the gamma dose were studied. It was found that many changes in the thermal, optical and structural properties of the CR-39 polymer could be produced by gamma irradiation via the degradation and cross linking mechanisms. Also, the gamma dose gave an advantage for increasing the correlation between the thermal stability of CR-39 polymer and the bond formation created by the ionizing effect of gamma radiation

  12. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr_3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. - Highlights: • A small-sized UAV airborne sensor system was developed. • Three radioactive models were chosen to simulate the Fukushima accident. • Both the air and ground radiation were considered in the models. • The efficiency calculations and MDAC values were given. • The sensor system is able to monitor in serious nuclear accidents.

  13. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    Science.gov (United States)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Mutagenic effects of gamma rays on soybean (Glycine max L.) germination and seedlings

    Science.gov (United States)

    Kusmiyati, F.; Sutarno; Sas, M. G. A.; Herwibawa, B.

    2018-01-01

    Narrow genetic diversity is a main problem restricting the progress of soybean breeding. One way to improve genetic diversity of plant is through mutation. The purpose of this study was to investigate effect of different dose of gamma rays as induced mutagen on physiological, morphological, and anatomical markers during seed germination and seedling growth of soybean. Seeds of soybean cultivars Dering-1 were irradiated with 11 doses of gamma rays (0, 5, 10, 20, 40, 80, 160, 320, 640, 1280, and 2560 Gy [Gray]. The research design was arranged in a completely randomized block design in three replicates. Results showed that soybean seed exposed at high doses (640, 1280, and 2560 Gy) did not survive more than 20 days, the doses were then removed from anatomical evaluation. Higher doses of gamma rays siginificantly reduced germination percentage at the first count and final count, coefficient of germination velocity, germination rate index, germination index, seedling height and seedling root length, and significantly increased mean germination time, first day of germination, last day of germination, and time spread of germination. However, the effects of gamma rays were varies for density, width, and length of stomata. The LD50 obtained based on survival percentage was 314.78 Gy. It can be concluded that very low and low doses of gamma rays (5-320 Gy) might be used to study the improvement of soybean diversity.

  15. Detection efficiency for radionuclides decaying by electron capture and gamma-Ray; Calculo de la eficiencia de deteccion de nucleidos que se desintegran por captura elec- tronica y emision gamma

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A; Fernandez, A

    1985-07-01

    In this paper, the electron capture partial counting efficiency vs the figure of merit for electron-capture and gamma-ray emitters has been computed. The radionuclides tabulated are 48{sup c}r, 54{sup M}n, 57{sup C}o 56{sup N}i, 72{sup S}e, 73{sup A}s, 85{sup S}r, 88{sup Z}r, 92{sup N}b, 103{sup P}d, 111{sup l}n, 119{sup S}b, 125{sup I}, 139{sup C}e and 152{sup D}y. It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 15 cm{sup 3}. (Author) 17 refs.

  16. Marine gamma spectrometric survey

    International Nuclear Information System (INIS)

    Kostoglodov, V.V.

    1979-01-01

    Presented are theoretical problems physical and geochemical prerequisites and possibilities of practical application of the method of continuous submarine gamma-spectrometric survey and radiometric survey destined for rapid study of the surface layer of marine sediments. Shown is high efficiency and advantages of this method in comparison with traditional and widely spread in marine geology methods of bottom sediments investigation

  17. Gamma-ray pulsars: Emission zones and viewing geometries

    Science.gov (United States)

    Romani, Roger W.; Yadigaroglu, I.-A.

    1995-01-01

    There are now a half-dozen young pulsars detected in high-energy photons by the Compton Gamma-Ray Observatory (CGRO), showing a variety of emission efficiencies and pulse profiles. We present here a calculation of the pattern of high-energy emission on the sky in a model which posits gamma-ray production by charge-depleted gaps in the outer magnetosphere. This model accounts for the radio to gamma-ray pulse offsets of the known pulsars, as well as the shape of the high-energy pulse profiles. We also show that about one-third of emitting young radio pulsars will not be detected due to beaming effects, while approximately 2.5 times the number of radio-selected gamma-ray pulsars will be viewed only high energies. Finally we compute the polarization angle variation and find that the previously misunderstood optical polarization sweep of the Crab pulsar arises naturally in this picture. These results strongly support an outer magnetosphere location for the gamma-ray emission.

  18. A gamma-ray discriminating neutron scintillator

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.; Cole, M.C.

    1994-01-01

    A neutron scintillator has been developed at Pacific Northwest Laboratory which responds directly to as little as 10 mrem/hour dose equivalent rate fast neutron fields. The scintillator is composed of CaF 2 :Eu or of NaI grains within a silicone rubber or polystyrene matrix, respectively. Neutrons colliding with the plastic matrix provide knockon protons, which in turn deposit energy within the grains of phosphor to produce pulses of light. Neutron interactions are discriminated from gamma-ray events on the basis of pulse height. Unlike NE-213 liquid scintillators, this solid scintillator requires no pulseshape discrimination and therefore requires less hardware. Neutron events are anywhere from two to three times larger than the gamma-ray exposures are compared to 0.7 MeV gamma-ray exposures. The CaF 2 :Eu/silicone rubber scintillator is nearly optically transparent, and can be made into a very sizable detector (4 cm x 1.5 cm) without degrading pulse height. This CaF 2 :Eu scintillator has been observed to have an absolute efficiency of 0.1% when exposed to 5-MeV accelerator-generated neutrons (where the absolute efficiency is the ratio of observed neutron events divided by the number of fast neutrons striking the detector)

  19. [Construction of a recombinant Escherichia coli BL21/ pET-28a-lpgad and the optimization of transformation conditions for the efficient production of gamma-aminobutyric acid].

    Science.gov (United States)

    Tian, Lingzhi; Xu, Meijuan; Rao, Zhiming

    2012-01-01

    In order to enhance gamma-aminobutyric acid production from L-glutamate efficiently, we amplified the key enzyme glutamate decarboxylase (GAD) encoding gene lpgad from the strain Lactobacillus plantarum GB 01-21 which was obtained by way of multi-mutagenesis and overexpressed it in E. coli BL21. Then we purified GAD by Ni-NTA affinity chromatography and characterized the enzyme to optimize the conditions of the whole-cell transformation. The results showed that the recombinant E. coli BL21 (pET-28a-lpgad) produced 8.53 U/mg GAD, which was increased by 3.24 fold compared with the GAD activity in L. plantarum. The optimum pH and temperature of the enzyme were pH 4.8 and 37 degrees C, respectively. At the same time, we found that Ca2+ and Mg2+ could increase the activity significantly. Based on this, we investigated gamma-aminobutyric acid transformation in 5 L fermentor under the optimum transformation conditions. Accordingly, the yield of gamma-aminobutyric acid was 204.5 g/L at 24 h when the 600 g L-glutamate was added and the mole conversion rate had reached 97.92%. The production of gamma-aminobutyric acid was improved by 42.5% compared with that under the unoptimized transformation conditions. This paved a way for the gamma-aminobutyric acid construction of the industrial applications.

  20. Radiative decay of the eta-, eta'-mesons in the nonlocal quark model. [eta(eta'). --> gamma gamma. ; eta. -->. pi. /sup +/. pi. /sup -/. gamma. ; eta. -->. pi. /sup 0/2. gamma. ; eta'. -->. rho/sup 0/. gamma. ; eta'. -->. omega gamma. ;. pi. /sup 0/. -->. gamma. e/sup +/e/sup -/; eta(eta'). -->. gamma mu. /sup +/. mu. /sup -/

    Energy Technology Data Exchange (ETDEWEB)

    Efimov, G V; Ivanov, M A; Nogovitsyn, E A [Joint Inst. for Nuclear Research, Dubna (USSR)

    1981-07-01

    P..--> gamma gamma.. (P=..pi../sup 0/, eta, eta'), eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta/sup 1/..-->..V..gamma.. (V=rho/sup 0/, ..omega..), p..--> gamma..l/sup +/l/sup -/ (p=..pi../sup 0/, eta, eta') radiation decays are studied for testing the applicability of the non-local quark model for description of the experimental data. The Feynman diagrams of these decays are presented, values of the widths of the Veta..--> gamma gamma.., eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta'..--> gamma gamma.., eta'..-->..rho/sup 0/..gamma.., eta'..--> omega gamma.. decays are calculated and given in the form of a table. Calculations are carried out for two values of the eta eta'-crossing angle: THETA=-11 deg and -18 deg. Values of invariant amplitudes of these decays are determined for ..pi../sup 0/..--> gamma..e/sup +/e/sup -/, eta..--> gamma mu../sup +/..mu../sup -/, eta'..--> gamma mu../sup +/..mu../sup -/ decays at THETA=-11 deg and -18 deg. The best agreement with the experimental data is noted to take place at THETA=-11 deg, the determined width of the eta..--> pi../sup 0/..gamma gamma.. decays is underestimated as compared with the experimental one.

  1. Removal of endocrine disruptors PAEs in drinking water by gamma-ray irradiation

    International Nuclear Information System (INIS)

    Zhao Yongfu; Zheng Zheng; Zheng Binguo; Wang Changbao; Li Lili

    2012-01-01

    Phthalic acid esters (PAEs) belong to environmental endocrine disruptor. The dimethyl phthalate (DMP), diethyl phthalate (DEP) and di-n-butyl phthalate (DBP) were selected for the radiation study. The removal efficiencies of DMP, DEP and DBP in drinking water by gamma-ray irradiation are discussed. The results show that these PAEs could be efficiently removed by gamma-ray irradiation. The removal efficiencies of DMP, DEP and DBP (12 mg/L) in aqueous solutions by 0.8 kGy gamma-ray treatment were 96.6%, 94.5% and 86.2%. The absorbed dose needed for the removal of total carbon in aqueous solutions was much larger than the doses for PAEs degradation. When 2 kGy was selected, the removal efficiencies of TC for DMP, DEP and DBP were only 23.6%, 14.3% and 12.9%. The study results also show that the radiation degradation reaction of PAEs should be divided into two stages: low dose addition reaction and high dose ring-opening reaction. This study is of significance in the disposal of micro-polluted drinking water. (authors)

  2. Full energy peak efficiency of NaI(Tl) gamma detectors and its analytical and semi-empirical representations

    International Nuclear Information System (INIS)

    Sudarshan, M.; Joseph, J.; Singh, R.

    1992-01-01

    The validity of various analytical functions and semi-empirical formulae proposed for representing the full energy peak efficiency (FEPE) curves of Ge(Li) and HPGe detectors has been tested for the FEPE of 7.6 cm x 7.6 cm and 5 cm x 5 cm Nal(Tl) detectors in the gamma energy range from 59.5 to 1408.03 keV. The functions proposed by East, and McNelles and Campbell provide by far the best representations of the present data. The semi-empirical formula of Mowatt describes the present data very well. The present investigation shows that some of the analytical functions and semi-empirical formulae, which represent the FEPE of the Ge(Li) and HPGe detectors very well, can be quite fruitfully used for Nal(Tl) detectors. (Author)

  3. Effect of cysteamine on sister chromatid exchange (SCE) induction by gamma rays

    International Nuclear Information System (INIS)

    Mendiola Cruz, M.T.

    1987-01-01

    The effect of different doses of cysteamine (3, 15 and 150 μg/g bw) on gamma ray-induced SCE was evaluated and compared with the responses obtained with regard to frequency of chromosomal aberrations, frequency of proliferating cells and the rate of cellular proliferating kinetics in mouse bone marrow cells in vivo. Groups of mice were either irradiated, treated with cysteamine and irradiated, only treated with cysteamine or left without treatment for determination of these parameters. The intraperitoneal administration of cysteamine preceding 1 Gy of gamma ray exposure, produces a dose dependent radioprotection on SCE-induction obtaining the greatest effect with 150 μg/g bw. However, this effect was not observed in the mitotic index nor in the average generation time. Chromosomic aberrations in animals irradiated after treatment with cysteamine were also detected. It was not observed any citotoxic or genotoxic effect produced by cysteamine per se. The results suggest that, under the experimental conditions of this study, the SCE are caused by free radicals produced by gamma radiation; not so, the additional damage indexes measured. (author)

  4. Gamma-ray surveys in uranium exploration

    International Nuclear Information System (INIS)

    1979-01-01

    This report is intended to provide newcomers to uranium exploration with an up-to-date statement of the principal factors to be considered in planning and using gamma-ray surveys. Since the report incorporates the results of recent research, and since its preparation was influenced by the cumulative experience of its contributors, it should also be useful to those who already have some knowledge of radioactivity surveys and methods. The intention is that the information and explanations given in the report will make it possible for gamma-ray surveys to be used in the most efficient way for a given exploration task

  5. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  6. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  7. Measurement of prompt fission gamma-ray spectra in fast neutron-induced fission

    International Nuclear Information System (INIS)

    Laborie, J.M.; Belier, G.; Taieb, J.

    2012-01-01

    Knowledge of prompt fission gamma-ray emission has been of major interest in reactor physics for a few years. Since very few experimental spectra were ever published until now, new measurements would be also valuable to improve our understanding of the fission process. An experimental method is currently being developed to measure the prompt fission gamma-ray spectrum from some tens keV up to 10 MeV at least. The mean multiplicity and total energy could be deduced. In this method, the gamma-rays are measured with a bismuth germanate (BGO) detector which has the advantage to present a high P/T ratio and a high efficiency compared to other gamma-ray detectors. The prompt fission neutrons are rejected by the time of flight technique between the BGO detector and a fission trigger given by a fission chamber or a scintillating active target. Energy and efficiency calibration of the BGO detector were carried out up to 10.76 MeV by means of the Al-27(p, gamma) reaction. First prompt fission gamma-ray spectrum measurements performed for the spontaneous fission of Cf-252 and for 1.7 and 15.6 MeV neutron-induced fission of U-238 at the CEA, DAM, DIF Van de Graaff accelerator, will be presented. (authors)

  8. Fermi Discovery of Gamma-Ray Emission from NGC 1275

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, Aous A.; /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Asano, K.; /Tokyo Inst. Tech.; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, Guido; /INFN, Trieste /Trieste U.; Bastieri, Denis; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bellazzini, R.; /INFN, Pisa; Blandford, R.D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bloom, Elliott D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bonamente, E.; /INFN, Perugia /Perugia U.; Borgland, A.W.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bregeon, J.; /INFN, Pisa; Brez, A.; /INFN, Pisa; Brigida, M.; /Bari U. /INFN, Bari; Bruel, P.; /Ecole Polytechnique; Burnett, Thompson H.; /Washington U., Seattle; Caliandro, G.A.; /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /IASF, Milan /IASF, Milan /DAPNIA, Saclay /ASDC, Frascati /INFN, Perugia /Perugia U. /SISSA, Trieste /George Mason U. /Naval Research Lab, Wash., D.C. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Montpellier U. /ASDC, Frascati /Sonoma State U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /Stockholm U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Naval Research Lab, Wash., D.C. /INFN, Trieste /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /CENBG, Gradignan /CENBG, Gradignan /Montpellier U. /Bari U. /INFN, Bari /Naval Research Lab, Wash., D.C. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Trieste /Hiroshima U.; /more authors..

    2009-05-15

    We report the discovery of high-energy (E > 100 MeV) {gamma}-ray emission from NGC 1275, a giant elliptical galaxy lying at the center of the Perseus cluster of galaxies, based on observations made with the Large Area Telescope (LAT) of the Fermi Gamma-ray Space Telescope. The positional center of the {gamma}-ray source is only {approx}3{prime} away from the NGC 1275 nucleus, well within the 95% LAT error circle of {approx}5{prime}. The spatial distribution of {gamma}-ray photons is consistent with a point source. The average flux and power-law photon index measured with the LAT from 2008 August 4 to 2008 December 5 are F{sub {gamma}} = (2.10 {+-} 0.23) x 10{sup -7} ph (>100 MeV) cm{sup -2} s{sup -1} and {Gamma} = 2.17 {+-} 0.05, respectively. The measurements are statistically consistent with constant flux during the four-month LAT observing period. Previous EGRET observations gave an upper limit of F{sub {gamma}} < 3.72 x 10{sup -8} ph (>100 MeV) cm{sup -2} s{sup -1} to the {gamma}-ray flux from NGC 1275. This indicates that the source is variable on timescales of years to decades, and therefore restricts the fraction of emission that can be produced in extended regions of the galaxy cluster. Contemporaneous and historical radio observations are also reported. The broadband spectrum of NGC 1275 is modeled with a simple one-zone synchrotron/synchrotron self-Compton model and a model with a decelerating jet flow.

  9. Optimization of plastic scintillator thicknesses for online beta/gamma detection

    Directory of Open Access Journals (Sweden)

    Pourtangestani K.

    2012-04-01

    Full Text Available For efficient beta detection in a mixed beta gamma field, Monte Carlo simulation models have been built to optimize the thickness of a plastic scintillator, used in a whole body monitor. The simulation has been performed using the MCNP/X code for different thicknesses of plastic scintillator from 150 μm to 600 μm. The relationship between the thickness of the scintillator and the efficiency of the detector has been analyzed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be the optimum thickness for high efficiency beta detection in the presence of low energy gamma-rays.

  10. Frontier differences and the global malmquist index

    DEFF Research Database (Denmark)

    Asmild, Mette

    2015-01-01

    This chapter reviews different ways of comparing the efficiency frontiers for subgroups within a data set, specifically program efficiency, the metatechnology (or technology gap) ratio and the global frontier difference index. The latter is subsequently used to define a global Malmquist index...

  11. Exploring energy efficiency in several European countries. An attribution analysis of the Divisia structural change index

    International Nuclear Information System (INIS)

    Fernández González, P.

    2015-01-01

    Highlights: • We present a new attribution analysis approach to study structural change index. • Based on LMDI method, we decompose changes in AEI in the EU in 1995–2010. • Mild AEI drop as a result of structural change, particularly in Eastern economies. • Transport, hotels and restaurants: positive contributors, specifically in Western EU. • Strategies should be focused on Industry: the most influential sector in reducing AEI. - Abstract: This paper aims at exploring the influence that the changes in sectoral composition in most EU economies have had on aggregate energy intensity. We rely on the so-called Logarithmic Mean Divisia Index (LMDI) method, implemented within a multiplicative energy intensity approach. Then, based on the Index Decomposition Analysis (IDA), we present, develop and apply a new methodology that enables the exploration of the contribution of each sector to the percent change in the structural factors index. Our findings show: (a) a greater importance of the intensity factor over the structural one, (b) a positive influence of structural change in some ex-communist countries, and (c) a strong, negative contribution of the industrial sector (including construction) to changes in aggregate energy intensity in most European economies, particularly in the Western ones. In short, adaptation to more efficient techniques, innovation, R and D, and substitution for higher quality energies, seem to be the action lines to follow, although in former communist countries these strategies should be accompanied by other policies aiming at accelerating the transition processes

  12. An evaluation study of research efficiency of the Guangzhou institute of respiratory diseases based on malmquist index.

    Science.gov (United States)

    Liao, Jian-Feng; Wang, Juan; Liang, Liang; Wu, Yong-Ding; Huang, Mei-Juan; Liu, Tian-Qiang; Zhou, Lin; Wang, Xin-Wang

    2016-10-01

    This study aimed to analyze the dynamic changes of the scientific research innovation efficiency of Guangzhou Institute of Respiratory Diseases (GIRD) during the year 2009-2013 to explore the reason for these changes and give some suggestions on how to improve the overall efficiency of the Institute. The panel data used in this study were taken from 19 research teams of GIRD during 2009 to 2013. Data envelopment analysis (DEA) based on Malmquist index (MI) was used to analyze the performance of each research team in terms of productivity changes over time. Data were analyzed using DEAP 2.1 software. The annual average increase rate of total factor productivity (TFP), technological progress, technical efficiency, pure technical efficiency, and scale efficiency was 30.4%, 22.5%, 6.4%, 0.9%, and 5.4%, respectively from 2009 to 2013. The scientific research innovation efficiency of the GIRD was generally high and kept on growing. The increase of TFP was mainly caused by the progress of tech, the descending of TFP in some teams should be mainly attributable to the declining pure technical efficiency, and scale efficiency on the whole, maintaining a stable growth at a low speed. To achieve higher scientific research innovation, GIRD not only needs to further improve the management level and introduce advanced management mode, but also needs to focus on optimization of resource allocation, as well as to strengthen the talent introduction, and continue to maintain the absorption of new technologies and innovation.

  13. Response functions of NaI(Tl) detectors to terrestrial gamma radiation

    International Nuclear Information System (INIS)

    Gyurcsak, J.; Lenda, A.

    1978-01-01

    Computer programs, serving for calculation of detector efficiency and energy deposition spectrum for scintillation crystals irradiated by isotropic or half-isotropic gamma-ray fields were elaborated. The Monte-Carlo models used in calculations are valid for gamma-ray energies 2 π geometry by the 1.5'' x 2'' probe with experimental results is given. (author)

  14. The Total Energy Efficiency Index for machine tools

    International Nuclear Information System (INIS)

    Schudeleit, Timo; Züst, Simon; Weiss, Lukas; Wegener, Konrad

    2016-01-01

    Energy efficiency in industries is one of the dominating challenges of the 21st century. Since the release of the eco-design directive 2005/32/EC in 2005, great research effort has been spent on the energy efficiency assessment for energy using products. The ISO (International Organization for Standardization) standardization body (ISO/TC 39 WG 12) currently works on the ISO 14955 series in order to enable the assessment of energy efficient design of machine tools. A missing piece for completion of the ISO 14955 series is a metric to quantify the design of machine tools regarding energy efficiency based on the respective assembly of components. The metric needs to take into account each machine tool components' efficiency and the need-oriented utilization in combination with the other components while referring to efficiency limits. However, a state of the art review reveals that none of the existing metrics is feasible to adequately match this goal. This paper presents a metric that matches all these criteria to promote the development of the ISO 14955 series. The applicability of the metric is proven in a practical case study on a turning machine. - Highlights: • Study for pushing forward the standardization work on the ISO 14955 series. • Review of existing energy efficiency indicators regarding three basic strategies to foster sustainability. • Development of a metric comprising the three basic strategies to foster sustainability. • Metric application for quantifying the energy efficiency of a turning machine.

  15. Gamma-ray tracking - A new detector concept for nuclear spectroscopy

    International Nuclear Information System (INIS)

    Gast, W.

    2001-01-01

    In the framework of an European collaboration the nest generation of large efficiency, high resolution spectrometers for nuclear spectroscopy is under development. The new spectrometers are large volume, segmented Ge-detectors featuring 3D position sensitivity in order to allow Gamma-Ray Tracking. That is, knowing the interaction positions and the energies released at each interaction, the track each gamma-ray follows during its scattering process inside the detector volume can be reconstructed on basis of the Compton-scattering formula. The resulting high add-back efficiency an effective granularity significantly improves peak-to-total ratio, efficiency, and Doppler-broadening of the spectrometer. In this contribution the states of the project concerning detector design and development of digital signal processing techniques to achieve an optimal 3D position sensitivity is presented. (authors)

  16. Study on cosmic gamma bursts in the ''KONUS'' experiment

    International Nuclear Information System (INIS)

    Mazets, E.P.; Golenetskij, S.V.; Il'inskij, V.N.; Panov, V.N.; Aptekar', R.L.; Gur'yan, Yu.A.; Sokolov, I.A.; Sokolova, Z.Ya.; Kharitonova, T.V.

    1979-01-01

    Made are the investigations of cosmic gamma bursts with the help of the ''Konus'' apparatus, positioned on the ''Venera 11'' and ''Venera 12'' automatic interplanetary stations. 37 gamma bursts have been recorded in the energy range from 50 to 150 keV during the observation period from September to December 1978. Time profiles of bursts on 4, 9 and 24.11.1978 are presented. For the most events the time of burst increase and decrease constitute parts and units of seconds. Differential energy spectra are measured for all recorded bursts. In many cases the spectrum shape is similar to the grade one with the 1.5-2.3 index. In a graphical form built up are the integral distributions of gamma bursts appearence frequency in dependence on their intensity and maximum capacity in the burst peak. Galaxy coordinates of the 17-teen bursts, for which a simple localization is possible, are put on the celestial sphere map. The type of the integral distributions and the source distribution about the celestial sphere show that the gamma burst sources are whithin the Galaxy

  17. RADIATION MECHANISM AND JET COMPOSITION OF GAMMA-RAY BURSTS AND GeV-TeV-SELECTED RADIO-LOUD ACTIVE GALACTIC NUCLEI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jin; Lu Ye; Zhang Shuangnan [National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Liang Enwei; Sun Xiaona [Department of Physics and GXU-NAOC Center for Astrophysics and Space Sciences, Guangxi University, Nanning 530004 (China); Zhang Bing, E-mail: lew@gxu.edu.cn [Department of Physics and Astronomy, University of Nevada, Las Vegas, NV 89154 (United States)

    2013-09-01

    Gamma-ray bursts (GRBs) and GeV-TeV-selected radio-loud active galactic nuclei (AGNs) are compared based on our systematic modeling of the observed spectral energy distributions of a sample of AGNs with a single-zone leptonic model. We show that the correlation between the jet power (P{sub jet}) and the prompt gamma-ray luminosity (L{sub jet}) of GRBs is consistent, within the uncertainties, with the correlation between jet power and the synchrotron peak luminosity (L{sub s,jet}) of flat spectrum radio quasars (FSRQs). Their radiation efficiencies ({epsilon}) are also comparable (>10% for most sources), which increase with the bolometric jet luminosity (L{sub bol,jet}) for FSRQs and with the L{sub jet} for GRBs with similar power-law indices. BL Lac objects (BL Lacs) do not follow the P{sub jet}-L{sub s,jet} relation of FSRQs. They have lower {epsilon} and L{sub bol,jet} values than FSRQs, and a tentative L{sub bol,jet}-{epsilon} relation is also found, with a power-law index different from that of the FSRQs. The magnetization parameters ({sigma}) of FSRQs are on average larger than that of BL Lacs. They are anti-correlated with {epsilon} for the FSRQs, but positively correlated with {epsilon} for the BL Lacs. GeV narrow-line Seyfert 1 galaxies potentially share similar properties with FSRQs. Based on the analogy between GRBs and FSRQs, we suggest that the prompt gamma-ray emission of GRBs is likely produced by the synchrotron process in a magnetized jet with high radiation efficiency, similar to FSRQs. The jets of BL Lacs, on the other hand, are less efficient and are likely more matter-dominated.

  18. Analysis of coincidence {gamma}-ray spectra using advanced background elimination, unfolding and fitting algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, M. E-mail: fyzimiro@savba.skfyzimiro@flnr.jinr.ru; Matousek, V. E-mail: matousek@savba.sk; Kliman, J.; Krupa, L.L.; Jandel, M

    2003-04-21

    The efficient algorithms to analyze multiparameter {gamma}-ray spectra are presented. They allow to search for peaks, to separate peaks from background, to improve the resolution and to fit 1-, 2-, 3-parameter {gamma}-ray spectra.

  19. X-ray and gamma-ray standards for detector calibration

    International Nuclear Information System (INIS)

    1991-09-01

    The IAEA established a Co-ordinated Research Programme (CRP) on the Measurements and Evaluation of X- and Gamma-Ray Standards for Detector Efficiency Calibration in 1986 with the aim of alleviating the generation of such discrepancies. Within the framework of this CRP, representatives of nine research groups from six Member States and one international organization performed a number of precise measurements and systematic in-depth evaluations of the required decay data. They have also contributed to the development of evaluation methodology and measurement techniques, and stimulated a number of such studies at laboratories not directly involved in the IAEA project. The results of the work of the CRP, which was finished in 1990, are presented in this report. Recommended values of half-lives and photon emission probabilities are given for a carefully selected set of radionuclides that are suitable for detector efficiency calibration (X-rays from 5 to 90 keV and gamma-rays from 30 to about 3000 keV). Detector efficiency calibration for higher gamma-ray energies (up to 14 MeV) is also considered. The evaluation procedures used to obtain the recommended values and their estimated uncertainties are reported, and a summary of the remaining discrepancies is given. Refs and tabs

  20. High-efficiency organic glass scintillators

    Science.gov (United States)

    Feng, Patrick L.; Carlson, Joseph S.

    2017-12-19

    A new family of neutron/gamma discriminating scintillators is disclosed that comprises stable organic glasses that may be melt-cast into transparent monoliths. These materials have been shown to provide light yields greater than solution-grown trans-stilbene crystals and efficient PSD capabilities when combined with 0.01 to 0.05% by weight of the total composition of a wavelength-shifting fluorophore. Photoluminescence measurements reveal fluorescence quantum yields that are 2 to 5 times greater than conventional plastic or liquid scintillator matrices, which accounts for the superior light yield of these glasses. The unique combination of high scintillation light-yields, efficient neutron/gamma PSD, and straightforward scale-up via melt-casting distinguishes the developed organic glasses from existing scintillators.

  1. Gamma sensitivity of the Eberline PCM-1

    International Nuclear Information System (INIS)

    Blanton, J.D.

    1988-01-01

    This paper reports that normally, alarm setpoints for the Eberline PCM-1 series personnel contamination monitors are calculated based upon efficiencies measured using 100-cm 2 or larger beta or mixed beta-gamma sources. This simulates the type of contamination most frequently encountered on personnel and clothing--low-level, distributed beta-gamma emitters. In most circumstances, the PCM-1's sensitivity to the other type of contamination encountered in nuclear plant work--hot particles--would be expected to be the same as, or better than, its sensitivity to distributed contamination. However, particles that are deposited on skin or clothing can be partially shielded from the view of the PCM-1's detectors. In these situations, the PCm-1's sensitivity to gamma radiation may be more relevant than its sensitivity to betas

  2. A study on the optimization of optical guide of gamma camera detector

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Cho, Gyu Seong; Kim, Ho Kyung; Lee, Wan No; Kim, Young Soo

    2000-01-01

    An optical guide, which is a light guide located between NaI(Tl) scintillation-crystal and array of photo-multiplier tubes (PMTs) in the gamma camera detector system, is an essential component to deliver the spatial information recorded in scintillator to the PMTs. Without the optical guide, the spatial information within the range of a single PMT could not be obtained. For the design of the optimal optical guide, it is necessary to characterize its properties, especially sensitivity and spatial resolution of detector. In this study, the thickness and the refractive index of optical guide, which affect not only on the sensitivity but also on the spatial resolution of gamma-camera detector, were investigated by using Monte Carlo simulation. A 12'x12'x3/8' NaI(Tl) and 23 PMTs with each 5' diameter were considered as a gamma-camera detector components. Interactions of optical photons in the scintillator and the optical guide were simulated using a commercial code DETECT97, and the spatial resolution, mainly interfered by the intrinsic inward distortion within the PMT, was investigated using our own ANGER program, which was developed to calculate positions of incident photons in the gamma camera. From the simulation results, it was found that an optical guide with 1.6 of refractive index and 10 mm of thickness give maximum sensitivity and minimum spatial distortion, respectively

  3. Exploring the extreme gamma-ray sky with HESS

    International Nuclear Information System (INIS)

    Sol, Helene

    2006-01-01

    The international HESS experiment. High Energy Stereoscopic System, fully operational since January 2004, is opening a new era for extreme gamma-ray astronomy. Located in Namibia, it is now the most sensitive detector for cosmic sources of very high energy (VHE) gamma-rays, in the tera-electron-volt (TeV) range. In July 2005, it had already more than double the number of sources detected at such energies, with the discovery of several active galactic nuclei (AGN), supernova remnants and plerions, a binary pulsar system, a microquasar candidate, and a sample of yet unidentified sources. HESS has also provide for the first time gamma-ray images of extended sources with the first astrophysical jet resolved in gamma-rays, and the first mapping of a shell supernova remnant, which proves the efficiency of in situ acceleration of particles up to 100 TeV and beyond

  4. Is the Universe More Transparent to Gamma Rays than Previously Thought?

    Science.gov (United States)

    Stecker, Floyd W.; Scully, Sean T.

    2009-01-01

    The MAGIC collaboration has recently reported the detection of the strong gamma-ray blazar 3C279 during a 1-2 day flare. They have used their spectral observations to draw conclusions regarding upper limits on the opacity of the Universe to high energy gamma-rays and, by implication, upper limits on the extragalactic mid-infrared background radiation. In this paper we examine the effect of gamma-ray absorption by the extragalactic infrared radiation on intrinsic spectra for this blazar and compare our results with the observational data on 3C279. We find agreement with our previous results, contrary to the recent assertion of the MAGIC group that the Universe is more transparent to gamma-rays than our calculations indicate. Our analysis indicates that in the energy range between approx. 80 and approx. 500 GeV, 3C279 has a best-fit intrinsic spectrum with a spectral index approx. 1.78 using our fast evolution model and approx. 2.19 using our baseline model. However, we also find that spectral indices in the range of 1.0 to 3.0 are almost as equally acceptable as the best fit spectral indices. Assuming the same intrinsic spectral index for this flare as for the 1991 flare from 3C279 observed by EGRET, viz., 2.02, which lies between our best fit indeces, we estimate that the MAGIC flare was approx.3 times brighter than the EGRET flare observed 15 years earlier.

  5. Uranium enrichment measurements without calibration using gamma rays above 100 keV

    International Nuclear Information System (INIS)

    Ruhter, Wayne D.; Lanier, Robert G.; Hayden, Catherine F.

    2001-01-01

    Full text: The verification of UF6 shipping cylinders is an important activity in routine safeguards inspections. Current measurement methods using either sodium-iodide or high-purity germanium detectors requires calibrations that are not always appropriate for field measurements, because of changes in geometry or container wall thickness. The introduction of the MGAU code demonstrated the usefulness of intrinsically calibrated measurements for inspections. MGAU uses the 100-keV region of the uranium gamma-ray spectrum. The thick walls of UF6 shipping cylinders preclude the routine use of MGAU for these measurements. We have developed a uranium enrichment measurement method for measurements using high- purity germanium detectors, which do not require calibration and uses uranium gamma rays above 100 keV. The method uses seven gamma rays from U-235 and U-238 to determine their relative detection efficiency intrinsically and with an additional gamma ray from U-234 the relative abundance of these three uranium isotopes. The method uses a function that describes the basic physical processes that predominately determine the relative detection efficiency curve, These are the detector efficiency, the absorption by the cylinder wall, and the self-absorption by the UF6 contents. We will describe this model and its performance on various uranium materials and detector types. (author)

  6. Efficiency and Productivity of County-level Public Hospitals Based on the Data Envelopment Analysis Model and Malmquist Index in Anhui, China.

    Science.gov (United States)

    Li, Nian-Nian; Wang, Cun-Hui; Ni, Hong; Wang, Heng

    2017-12-05

    China began to implement the national medical and health system and public hospital reforms in 2009 and 2012, respectively. Anhui Province is one of the four pilot provinces, and the medical reform measures received wide attention nationwide. The effectiveness of the above reform needs to get attention. This study aimed to master the efficiency and productivity of county-level public hospitals based on the data envelopment analysis (DEA) model and Malmquist index in Anhui, China, and then provide improvement measures for the future hospital development. We chose 12 country-level hospitals based on geographical distribution and the economic development level in Anhui Province. Relevant data that were collected in the field and then sorted were provided by the administrative departments of the hospitals. DEA models were used to calculate the dynamic efficiency and Malmquist index factors for the 12 institutions. During 2010-2015, the overall average relative service efficiency of 12 county-level public hospitals was 0.926, and the number of hospitals achieved an effective DEA for each year from 2010 to 2015 was 4, 6, 7, 7, 6, and 8, respectively, as measured using DEA. During this same period, the average overall production efficiency was 0.983, and the total productivity factor had declined. The overall production efficiency of five hospitals was >1, and the rest are productivity has not been effectively improved. County-level public hospitals need to combine their own reality to find their own deficiencies.

  7. A Benchmark for Evaluating Moving Object Indexes

    DEFF Research Database (Denmark)

    Chen, Su; Jensen, Christian Søndergaard; Lin, Dan

    2008-01-01

    that targets techniques for the indexing of the current and near-future positions of moving objects. This benchmark enables the comparison of existing and future indexing techniques. It covers important aspects of such indexes that have not previously been covered by any benchmark. Notable aspects covered......Progress in science and engineering relies on the ability to measure, reliably and in detail, pertinent properties of artifacts under design. Progress in the area of database-index design thus relies on empirical studies based on prototype implementations of indexes. This paper proposes a benchmark...... include update efficiency, query efficiency, concurrency control, and storage requirements. Next, the paper applies the benchmark to half a dozen notable moving-object indexes, thus demonstrating the viability of the benchmark and offering new insight into the performance properties of the indexes....

  8. Empirical Study on Total Factor Productive Energy Efficiency in Beijing-Tianjin-Hebei Region-Analysis based on Malmquist Index and Window Model

    Science.gov (United States)

    Xu, Qiang; Ding, Shuai; An, Jingwen

    2017-12-01

    This paper studies the energy efficiency of Beijing-Tianjin-Hebei region and to finds out the trend of energy efficiency in order to improve the economic development quality of Beijing-Tianjin-Hebei region. Based on Malmquist index and window analysis model, this paper estimates the total factor energy efficiency in Beijing-Tianjin-Hebei region empirically by using panel data in this region from 1991 to 2014, and provides the corresponding political recommendations. The empirical result shows that, the total factor energy efficiency in Beijing-Tianjin-Hebei region increased from 1991 to 2014, mainly relies on advances in energy technology or innovation, and obvious regional differences in energy efficiency to exist. Throughout the window period of 24 years, the regional differences of energy efficiency in Beijing-Tianjin-Hebei region shrank. There has been significant convergent trend in energy efficiency after 2000, mainly depends on the diffusion and spillover of energy technologies.

  9. The Gamma Gap and All-Cause Mortality

    Science.gov (United States)

    Juraschek, Stephen P.; Moliterno, Alison R.; Checkley, William; Miller, Edgar R.

    2015-01-01

    Background The difference between total serum protein and albumin, i.e. the gamma gap, is a frequently used clinical screening measure for both latent infection and malignancy. However, there are no studies defining a positive gamma gap. Further, whether it is an independent risk factor of mortality is unknown. Methods and Findings This study examined the association between gamma gap, all-cause mortality, and specific causes of death (cardiovascular, cancer, pulmonary, or other) in 12,260 participants of the National Health and Nutrition Examination Survey (NHANES) from 1999–2004. Participants had a comprehensive metabolic panel measured, which was linked with vital status data from the National Death Index. Cause of death was based on ICD10 codes from death certificates. Analyses were performed with Cox proportional hazards models adjusted for mortality risk factors. The mean (SE) age was 46 (0.3) years and the mean gamma gap was 3.0 (0.01) g/dl. The population was 52% women and 10% black. During a median follow-up period of 4.8 years (IQR: 3.3 to 6.2 years), there were 723 deaths. The unadjusted 5-year cumulative incidences across quartiles of the gamma gap (1.7–2.7, 2.8–3.0, 3.1–3.2, and 3.3–7.9 g/dl) were 5.7%, 4.2%, 5.5%, and 7.8%. After adjustment for risk factors, participants with a gamma gap of ≥3.1 g/dl had a 30% higher risk of death compared to participants with a gamma gap gap (per 1.0 g/dl) was most strongly associated with death from pulmonary causes (HR 2.22; 95%CI: 1.19, 4.17; P = 0.01). Conclusions The gamma gap is an independent risk factor for all-cause mortality at values as low as 3.1 g/dl (in contrast to the traditional definition of 4.0 g/dl), and is strongly associated with death from pulmonary causes. Future studies should examine the biologic pathways underlying these associations. PMID:26629820

  10. A prototype of radioactive waste drum monitor by non-destructive assays using gamma spectrometry

    International Nuclear Information System (INIS)

    Thanh, Tran Thien; Trang, Hoang Thi Kieu; Chuong, Huynh Dinh; Nguyen, Vo Hoang; Tran, Le Bao; Tam, Hoang Duc; Tao, Chau Van

    2016-01-01

    In this work, segmented gamma scanning and the gamma emission tomography were used to locate unknown sources in a radioactive waste drum. The simulated detector response function and full energy peak efficiency are compared to corresponding experimental data and show about 5.3% difference for an energy ranging from 81 keV to 1332.5 keV for point sources. Computation of the corresponding activity is in good agreement with the true values. - Highlights: • Segmented gamma scanning and gamma emission tomography are used to locate point source in waste drums. • The PENELOPE software is used to compute the detection efficiency of the localized point source in the waste drum. • The activity of "1"3"7Cs and "6"0Co point source could be determined with an accuracy better than 10% for air and sand matrices.

  11. Gamma knife radiosurgery for acoustic neurinomas. Pt. 1. The analysis of tumor control

    International Nuclear Information System (INIS)

    Fukuoka, Seiji; Seo, Yoshinobu; Nakagawara, Jyoji

    1997-01-01

    Forty-three patients with the unilateral type of acoustic neurinoma who were treated with gamma knife radiosurgery were analyzed from the viewpoint of tumor control. The follow-up period ranged from 22 to 55 months. The tumors were treated with marginal radiation doses of 9-15 Gy with multiple isocenters. The actuarial tumor reduction rates were 42% at one year, 75% at 2 years, and 92% at 3 years after gamma knife radiosurgery. Transient tumor expansion was seen in 33% of patients, which correlated with previous surgical cases. The present control rate was 91%. SPECT was performed on 15 selected patients before and 1 year and 2 years after gamma knife radiosurgery. 201 TlCl SPECT was used to determine tumor viability, and the early and delayed 99m Tc-DTPA-HSA-D SPECT images were used to assess tumor vascularity and permeability, respectively. The Tl index and HSA-D index of the delayed images were not significantly different from the respective preoperative values. However, there was a statistically significant decrease in the HSA-D index of the early images 1 year after treatment. A statistically significant reduction in tumor volume was seen 2 years after treatment in these 15 patients, meaning that a reduction in tumor vascularity was followed by a reduction in tumor size. One patient underwent surgical excision of the tumor 18 months after gamma knife radiosurgery because the tumor had expanded and resulted in cerebellar ataxia. Histopathologic investigation revealed the presence of some tumor cells with irregularly shaped nuclei and marked intimal thickening or obliteration of the tumor vessels. (K.H.)

  12. Gamma-Ray Observations of Tycho’s Supernova Remnant with VERITAS and Fermi

    Energy Technology Data Exchange (ETDEWEB)

    Archambault, S.; Bourbeau, E.; Feng, Q.; Griffin, S. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Archer, A.; Buckley, J. H.; Bugaev, V.; Errando, M. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Benbow, W.; Cerruti, M. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Bird, R.; Buchovecky, M. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Cui, W.; Finley, J. P. [Department of Physics and Astronomy, Purdue University, West Lafayette, IN 47907 (United States); Dwarkadas, V. V. [Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL 60637 (United States); Falcone, A. [Department of Astronomy and Astrophysics, 525 Davey Lab, Pennsylvania State University, University Park, PA 16802 (United States); Fleischhack, H. [DESY, Platanenallee 6, D-15738 Zeuthen (Germany); Fortson, L. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Furniss, A., E-mail: nahee@uchicago.edu [Department of Physics, California State University—East Bay, Hayward, CA 94542 (United States); and others

    2017-02-10

    High-energy gamma-ray emission from supernova remnants (SNRs) has provided a unique perspective for studies of Galactic cosmic-ray acceleration. Tycho’s SNR is a particularly good target because it is a young, type Ia SNR that has been well-studied over a wide range of energies and located in a relatively clean environment. Since the detection of gamma-ray emission from Tycho’s SNR by VERITAS and Fermi -LAT, there have been several theoretical models proposed to explain its broadband emission and high-energy morphology. We report on an update to the gamma-ray measurements of Tycho’s SNR with 147 hr of VERITAS and 84 months of Fermi -LAT observations, which represent about a factor of two increase in exposure over previously published data. About half of the VERITAS data benefited from a camera upgrade, which has made it possible to extend the TeV measurements toward lower energies. The TeV spectral index measured by VERITAS is consistent with previous results, but the expanded energy range softens a straight power-law fit. At energies higher than 400 GeV, the power-law index is 2.92 ± 0.42{sub stat} ± 0.20{sub sys}. It is also softer than the spectral index in the GeV energy range, 2.14 ± 0.09{sub stat} ± 0.02{sub sys}, measured in this study using Fermi -LAT data. The centroid position of the gamma-ray emission is coincident with the center of the remnant, as well as with the centroid measurement of Fermi -LAT above 1 GeV. The results are consistent with an SNR shell origin of the emission, as many models assume. The updated spectrum points to a lower maximum particle energy than has been suggested previously.

  13. Field Applications of Gamma Column Scanning Technology

    International Nuclear Information System (INIS)

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  14. Simultaneous adsorption and degradation of {gamma}-HCH by nZVI/Cu bimetallic nanoparticles with activated carbon support

    Energy Technology Data Exchange (ETDEWEB)

    Chang Chun; Lian Fei [Key Laboratory of Pollution Process and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071 (China); Key Laboratory of Urban Ecology Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin 300071 (China); Zhu Lingyan, E-mail: zhuly@nankai.edu.cn [Key Laboratory of Pollution Process and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071 (China); Key Laboratory of Urban Ecology Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin 300071 (China)

    2011-10-15

    Cu amended zero valent iron bimetallic nanoparticles were synthesized by doping Cu on the surface of iron. They were incorporated with granular activated carbon (AC) to prepare supported particles (AC-Fe{sup 0}-Cu), which were used to remove {gamma}-HCH. Cu on the surface of iron enhanced the dechlorination activity of Fe{sup 0}. The dechlorination rate constant (k{sub obs}) increased with the Cu loading on the surface of iron and the maximum was achieved with 6.073% Cu. AC as a support was effective for increasing the dispersion of the nanoparticles and avoiding the agglomeration of the metallic nanoparticles. The simultaneous adsorption of {gamma}-HCH on AC accelerated the degradation rate of {gamma}-HCH by the bimetals. After reaction for 165 min, around 99% of {gamma}-HCH was removed by the solids of AC-Fe{sup 0}-Cu. In addition, AC could adsorb the degradation products. The degradation of {gamma}-HCH was mainly through dehydrochlorination and dichloroelmination based on the intermediate products detected by GC/MS. - Highlights: > Deposition of Cu on the surface of Fe enhances its dechlorination efficiency toward {gamma}-HCH. > Incorporation of the bimetallic nanoparticles with activated carbon (AC) reduces their agglomeration. > AC support increases the contact of {gamma}-HCH with the nanoparticles and enhances the degradation efficiency. > The AC support adsorbs {gamma}-HCH and its degradation products, reducing their ecological risks in water. - Impregnation of Cu amended iron on AC enhances the removal efficiency of {gamma}-HCH and reduces the concentrations of its intermediates in aqueous solution.

  15. Determination of gamma ray shielding parameters of rocks and concrete

    Science.gov (United States)

    Obaid, Shamsan S.; Gaikwad, Dhammajyot K.; Pawar, Pravina P.

    2018-03-01

    Gamma shielding parameters such as mass attenuation coefficient (μ/ρ), effective atomic number (Zeff) and electron density (Neff) have been measured and calculated for rocks and concrete in the energy range 122-1330 keV. The measurements have been carried out at 122, 356, 511, 662, 1170, 1275, 1330 keV gamma ray energies using a gamma spectrometer includes a NaI(Tl) scintillation detector and MCA card. The atomic and electronic cross sections have also been investigated. Experimental and calculated (WinXCom) values were compared, and good agreement has been observed within the experimental error. The obtained results showed that feldspathic basalt, compact basalt, volcanic rock, dolerite and pink granite are more efficient than the sandstone and concrete for gamma ray shielding applications.

  16. Indexed variation graphs for efficient and accurate resistome profiling.

    Science.gov (United States)

    Rowe, Will P M; Winn, Martyn D

    2018-05-14

    Antimicrobial resistance remains a major threat to global health. Profiling the collective antimicrobial resistance genes within a metagenome (the "resistome") facilitates greater understanding of antimicrobial resistance gene diversity and dynamics. In turn, this can allow for gene surveillance, individualised treatment of bacterial infections and more sustainable use of antimicrobials. However, resistome profiling can be complicated by high similarity between reference genes, as well as the sheer volume of sequencing data and the complexity of analysis workflows. We have developed an efficient and accurate method for resistome profiling that addresses these complications and improves upon currently available tools. Our method combines a variation graph representation of gene sets with an LSH Forest indexing scheme to allow for fast classification of metagenomic sequence reads using similarity-search queries. Subsequent hierarchical local alignment of classified reads against graph traversals enables accurate reconstruction of full-length gene sequences using a scoring scheme. We provide our implementation, GROOT, and show it to be both faster and more accurate than a current reference-dependent tool for resistome profiling. GROOT runs on a laptop and can process a typical 2 gigabyte metagenome in 2 minutes using a single CPU. Our method is not restricted to resistome profiling and has the potential to improve current metagenomic workflows. GROOT is written in Go and is available at https://github.com/will-rowe/groot (MIT license). will.rowe@stfc.ac.uk. Supplementary data are available at Bioinformatics online.

  17. Assessment of Annual Effective Dose for Natural Radioactivity of Gamma Emitters in Biscuit Samples in Iraq.

    Science.gov (United States)

    Abojassim, Ali Abid; Al-Alasadi, Lubna A; Shitake, Ahmed R; Al-Tememie, Faeq A; Husain, Afnan A

    2015-09-01

    Biscuits are an important type of food, widely consumed by babies in Iraq and other countries. This work uses gamma spectroscopy to measure the natural radioactivity due to long-lived gamma emitters in children's biscuits; it also estimates radiation hazard indices, that is, the radium equivalent activity, the representative of gamma level index, the internal hazard index, and the annual effective dose in children. Ten samples were collected from the Iraqi market from different countries of origin. The average specific activities for (226)Ra, (232)Th, and (40)K were 9.390, 3.1213, and 214.969 Bq/kg, respectively, but the average of the radium equivalent activity and the internal hazard index were 33.101 Bq/kg and 0.107, respectively. The total average annual effective dose from consumption by adults, children, and infants is estimated to be 0.655, 1.009, and 0.875 mSv, respectively. The values found for specific activity, radiation hazard indices, and annual effective dose in all samples in this study were lower than worldwide median values for all groups; therefore, these values are found to be safe.

  18. The FIR-Radio Correlation in Rapidly Star-Forming Galaxies: The Spectral Index Problem and Proton Calorimetry

    Science.gov (United States)

    Thompson, Todd A.; Lacki, Brian C.

    We review the physics of the FIR-radio correlation (FRC) of star-forming galaxies, focusing on "electron calorimetry" as an explanation. We emphasize the importance of the "spectral index problem"—that galaxies have flatter GHz synchrotron spectra than predicted in the strong-cooling calorimeter limit. We argue that these shallow spectra require significant bremsstrahlung and/or ionization losses for the primary and secondary CR electron/positron populations. This then implies that CR protons suffer strong pionic losses before escape in dense starburst galaxies ("proton calorimetry"), and that these systems should be gamma-ray bright, forming a FIR-gamma-ray correlation. Implications for the diffuse non-thermal cosmic gamma-ray and neutrino backgrounds are mentioned. Caveats and uncertainties, as well as other solutions to the "spectral index problem" such as rapid advection of CRs in starburst superwinds, are highlighted.

  19. Effects of Gamma Irradiation on Polyvinylidene Fluoride Thin Films

    Science.gov (United States)

    Madivalappa, Shivaraj; Jali, V. M.

    2018-02-01

    Polyvinylidene fluoride thin films were synthesized by Sol-Gel method with spin rate of 3000 rpm for 30 sec on ITO glass substrates and were annealed at 170 C. The films were irradiated by Gamma radiation with different doses (10, 30, 40 and 50 kGy). XRD and FTIR spectra have been obtained to identify the presence of α / β phases. Mean crystallite size was calculated by Scherer’s equation. Different vibrational bands were identified and percentage of β phase was determined by FTIR analysis. Optical properties like band gap, refractive index, optical activation energy have been determined. Surface morphology and compositions of pristine and gamma irradiated PVDF thin films were confirmed respectively, by SEM and Energy dispersive X-ray analysis. The comparison of the structural and optical optical properties of pristine PVDF polymer film has been made with those of the Gamma irradiated films.

  20. $\\gamma$-Ray Pulsars: Emission Zones and Viewing Geometries

    OpenAIRE

    Romani, Roger W.; Yadigaroglu, I. -A.

    1994-01-01

    There are now a half dozen young pulsars detected in high energy photons by the Compton GRO, showing a variety of emission efficiencies and pulse profiles. We present here a calculation of the pattern of high energy emission on the sky in a model which posits $\\gamma$-ray production by charge depleted gaps in the outer magnetosphere. This model accounts for the radio to $\\gamma$-ray pulse offsets of the known pulsars, as well as the shape of the high energy pulse profiles. We also show that $...

  1. Crystal-diffraction spectrometer of increased efficiency

    International Nuclear Information System (INIS)

    Saukov, A.I.; Gornitsyn, G.A.; Morozov, N.A.

    1985-01-01

    The geometry of the spectrometer is illustrated in this paper. An attempt is made to achieve optimal design of the spectrometer by finding the coefficient of reflection of the gamma radiation from the various Ge planes. In these experiments, the Du Mond design was used in the spectrometer. Illustrations are provided to explain dependence of the relative efficiency upon the energy of the gamma quanta

  2. Calibration of Ge gamma-ray spectrometers for complex sample geometries and matrices

    Energy Technology Data Exchange (ETDEWEB)

    Semkow, T.M., E-mail: thomas.semkow@health.ny.gov [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, State University of New York, Rensselaer, NY 12144 (United States); Bradt, C.J.; Beach, S.E.; Haines, D.K.; Khan, A.J.; Bari, A.; Torres, M.A.; Marrantino, J.C.; Syed, U.-F. [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Kitto, M.E. [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Department of Environmental Health Sciences, School of Public Health, University at Albany, State University of New York, Rensselaer, NY 12144 (United States); Hoffman, T.J. [Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY 12201 (United States); Curtis, P. [Kiltel Systems, Inc., Clyde Hill, WA 98004 (United States)

    2015-11-01

    A comprehensive study of the efficiency calibration and calibration verification of Ge gamma-ray spectrometers was performed using semi-empirical, computational Monte-Carlo (MC), and transfer methods. The aim of this study was to evaluate the accuracy of the quantification of gamma-emitting radionuclides in complex matrices normally encountered in environmental and food samples. A wide range of gamma energies from 59.5 to 1836.0 keV and geometries from a 10-mL jar to 1.4-L Marinelli beaker were studied on four Ge spectrometers with the relative efficiencies between 102% and 140%. Density and coincidence summing corrections were applied. Innovative techniques were developed for the preparation of artificial complex matrices from materials such as acidified water, polystyrene, ethanol, sugar, and sand, resulting in the densities ranging from 0.3655 to 2.164 g cm{sup −3}. They were spiked with gamma activity traceable to international standards and used for calibration verifications. A quantitative method of tuning MC calculations to experiment was developed based on a multidimensional chi-square paraboloid. - Highlights: • Preparation and spiking of traceable complex matrices in extended geometries. • Calibration of Ge gamma spectrometers for complex matrices. • Verification of gamma calibrations. • Comparison of semi-empirical, computational Monte Carlo, and transfer methods of Ge calibration. • Tuning of Monte Carlo calculations using a multidimensional paraboloid.

  3. Calibration of Ge gamma-ray spectrometers for complex sample geometries and matrices

    International Nuclear Information System (INIS)

    Semkow, T.M.; Bradt, C.J.; Beach, S.E.; Haines, D.K.; Khan, A.J.; Bari, A.; Torres, M.A.; Marrantino, J.C.; Syed, U.-F.; Kitto, M.E.; Hoffman, T.J.; Curtis, P.

    2015-01-01

    A comprehensive study of the efficiency calibration and calibration verification of Ge gamma-ray spectrometers was performed using semi-empirical, computational Monte-Carlo (MC), and transfer methods. The aim of this study was to evaluate the accuracy of the quantification of gamma-emitting radionuclides in complex matrices normally encountered in environmental and food samples. A wide range of gamma energies from 59.5 to 1836.0 keV and geometries from a 10-mL jar to 1.4-L Marinelli beaker were studied on four Ge spectrometers with the relative efficiencies between 102% and 140%. Density and coincidence summing corrections were applied. Innovative techniques were developed for the preparation of artificial complex matrices from materials such as acidified water, polystyrene, ethanol, sugar, and sand, resulting in the densities ranging from 0.3655 to 2.164 g cm −3 . They were spiked with gamma activity traceable to international standards and used for calibration verifications. A quantitative method of tuning MC calculations to experiment was developed based on a multidimensional chi-square paraboloid. - Highlights: • Preparation and spiking of traceable complex matrices in extended geometries. • Calibration of Ge gamma spectrometers for complex matrices. • Verification of gamma calibrations. • Comparison of semi-empirical, computational Monte Carlo, and transfer methods of Ge calibration. • Tuning of Monte Carlo calculations using a multidimensional paraboloid

  4. Antireflective sub-wavelength structures for improvement of the extraction efficiency and color rendering index of monolithic white light-emitting diode

    DEFF Research Database (Denmark)

    Ou, Yiyu; Corell, Dennis Dan; Dam-Hansen, Carsten

    2011-01-01

    We have theoretically investigated the influence of antireflective sub-wavelength structures on a monolithic white light-emitting diode (LED). The simulation is based on the rigorous coupled wave analysis (RCWA) algorithm, and both cylinder and moth-eye structures have been studied in the work. Our...... simulation results show that a moth-eye structure enhances the light extraction efficiency over the entire visible light range with an extraction efficiency enhancement of up to 26 %. Also for the first time to our best knowledge, the influence of sub-wavelength structures on both the color rendering index...

  5. Plutonium isotopic measurements by gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Haas, F.X.; Lemming, J.F.

    1976-01-01

    A nondestructive technique is described for calculating plutonium-238, plutonium-240, plutonium-241 and americium-241 relative to plutonium-239 from measured peak areas in the high resolution gamma-ray spectra of solid plutonium samples. Gamma-ray attenuation effects were minimized by selecting sets of neighboring peaks in the spectrum whose components are due to the different isotopes. Since the detector efficiencies are approximately the same for adjacent peaks, the accuracy of the isotopic ratios is dependent on the half-lives, branching intensities, and measured peak areas. The data presented describe the results obtained by analyzing gamma-ray spectra in the energy region from 120 to 700 keV. Most of the data analyzed were obtained from plutonium material containing 6 percent plutonium-240. Sample weights varied from 0.25 g to approximately 1.2 kg. The methods were also applied to plutonium samples containing up to 23 percent plutonium-240 with weights of 0.25 to 200 g. Results obtained by gamma-ray spectroscopy are compared to chemical analyses of aliquots taken from the bulk samples

  6. The Gamma Gap and All-Cause Mortality.

    Directory of Open Access Journals (Sweden)

    Stephen P Juraschek

    Full Text Available The difference between total serum protein and albumin, i.e. the gamma gap, is a frequently used clinical screening measure for both latent infection and malignancy. However, there are no studies defining a positive gamma gap. Further, whether it is an independent risk factor of mortality is unknown.This study examined the association between gamma gap, all-cause mortality, and specific causes of death (cardiovascular, cancer, pulmonary, or other in 12,260 participants of the National Health and Nutrition Examination Survey (NHANES from 1999-2004. Participants had a comprehensive metabolic panel measured, which was linked with vital status data from the National Death Index. Cause of death was based on ICD10 codes from death certificates. Analyses were performed with Cox proportional hazards models adjusted for mortality risk factors. The mean (SE age was 46 (0.3 years and the mean gamma gap was 3.0 (0.01 g/dl. The population was 52% women and 10% black. During a median follow-up period of 4.8 years (IQR: 3.3 to 6.2 years, there were 723 deaths. The unadjusted 5-year cumulative incidences across quartiles of the gamma gap (1.7-2.7, 2.8-3.0, 3.1-3.2, and 3.3-7.9 g/dl were 5.7%, 4.2%, 5.5%, and 7.8%. After adjustment for risk factors, participants with a gamma gap of ≥3.1 g/dl had a 30% higher risk of death compared to participants with a gamma gap <3.1 g/dl (HR: 1.30; 95%CI: 1.08, 1.55; P = 0.006. Gamma gap (per 1.0 g/dl was most strongly associated with death from pulmonary causes (HR 2.22; 95%CI: 1.19, 4.17; P = 0.01.The gamma gap is an independent risk factor for all-cause mortality at values as low as 3.1 g/dl (in contrast to the traditional definition of 4.0 g/dl, and is strongly associated with death from pulmonary causes. Future studies should examine the biologic pathways underlying these associations.

  7. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  8. An analytical calculation of the peak efficiency for cylindrical sources perpendicular to the detector axis in gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Julio C. [Autoridad Regulatoria Nuclear, Laboratorio de Espectrometria Gamma-CTBTO, Av. Del Libertador 8250, C1429BNP Buenos Aires (Argentina)], E-mail: jaguiar@sede.arn.gov.ar

    2008-08-15

    An analytical expression for the so-called full-energy peak efficiency {epsilon}(E) for cylindrical source with perpendicular axis to an HPGe detector is derived, using point-source measurements. The formula covers different measuring distances, matrix compositions, densities and gamma-ray energies; the only assumption is that the radioactivity is homogeneously distributed within the source. The term for the photon self-attenuation is included in the calculation. Measurements were made using three different sized cylindrical sources of {sup 241}Am, {sup 57}Co, {sup 137}Cs, {sup 54}Mn, and {sup 60}Co with corresponding peaks of 59.5, 122, 662, 835, 1173, and 1332 keV, respectively, and one measurement of radioactive waste drum for 662, 1173, and 1332 keV.

  9. Efficiency of Pollution Tolerance Index (PTI of macroinvertebrates in detecting aquatic pollution in an oxbow lake in India

    Directory of Open Access Journals (Sweden)

    Dipankar Ghosh

    2017-11-01

    Full Text Available This paper evaluates the efficiency of a macroinvertebrate-based Pollution Tolerance Index (PTI in detecting aquatic pollution in the Chhariganga oxbow lake in India. In this lake, calculated PTIs were compared with results from an array of physicochemical water and sediment parameters and to a macroinvertebrate diversity assessment conducted in parallel for the same lake. The obtained PTI values fell in a range (between 20 and 31 that are indicative of an absence of organic pollution according to the literature, and are normally reported for systems devoid of anthropogenic activity (for instance no monsoonal polluting jute retting activities. However, in the light of the results for the assessed water and sediment physicochemical parameters, and the support of diversity indexes of macroinvertebrates, using data from the same lake, it was possible to conclude that the obtained PTI values do not reflect the true pollution status of this oxbow lake. As PTI values and diversity indexes contradict each other in detecting pollution, it is advised to take both parameters into consideration when using macroinvertebrates to assess aquatic health.

  10. The {sup 124}Sb activity standardization by gamma spectrometry for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: marcandida@yahoo.com.b [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil); Iwahara, A.; Delgado, J.U.; Poledna, R.; Silva, R.L. da [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes, Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear (SEMRA/LNMRI/IRD/CNEN), Av. Salvador Allende s/n, Recreio, Rio de Janeiro, RJ, CEP 22780-160 (Brazil)

    2010-07-21

    This work describes a metrological activity determination of {sup 124}Sb, which can be used as radiotracer, applying gamma spectrometry methods with hyper pure germanium detector and efficiency curves. This isotope with good activity and high radionuclidic purity is employed in the form of meglumine antimoniate (Glucantime) or sodium stibogluconate (Pentostam) to treat leishmaniasis. {sup 124}Sb is also applied in animal organ distribution studies to solve some questions in pharmacology. {sup 124}Sb decays by {beta}-emission and it produces several photons (X and gamma rays) with energy varying from 27 to 2700 keV. Efficiency curves to measure point {sup 124}Sb solid sources were obtained from a {sup 166m}Ho standard that is a multi-gamma reference source. These curves depend on radiation energy, sample geometry, photon attenuation, dead time and sample-detector position. Results for activity determination of {sup 124}Sb samples using efficiency curves and a high purity coaxial germanium detector were consistent in different counting geometries. Also uncertainties of about 2% (k=2) were obtained.

  11. High gamma dose response of the electrical properties of polyethylene terephthalate thin films

    International Nuclear Information System (INIS)

    Radwan, R.M.

    2007-01-01

    Electrical properties of polyethylene terephthalate (PET), irradiated with gamma rays, have been investigated. The PET films were irradiated with high gamma dose levels in the range from 100 to 2000 kGy. The changes in the DC (σ DC ) and the ac (σ ac ) conductivities, with the dose, have been performed. The effect of gamma irradiation on the dielectric constant (ε') and loss (ε'') has been determined. Also, the dose dependence of the frequency exponent index (S), the resonance frequency (Fc) and the hopping frequency (ω P ) have been obtained. The obtained results show that increasing gamma dose leads to slight increase in σ DC , σ ac and ε', while no change was observed in ε'' value. Meanwhile, S, Fc and ω P are inversely proportional to the dose. Accordingly, the study suggests the possibility of using PET films in electronic components (capacitors, resistors, etc.), especially that operate at high gamma dose environments for the frequency independent applications

  12. Prompt gamma neutron activation analysis facility at the RA-6 research reactor

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Calzetta, O

    2004-01-01

    A prompt gamma neutron activation activation analysis facility was developed at the 500 kw thermal power RA-6 research reactor of the Bariloche Atomic Center, Argentina.This facility consist of a radial beam port with external positioning of the sample.The gamma radiation is reduced by a bismuth filter placed inside the extraction tube and the beam diameter is limited by a set of two collimators up to 5 cm.The neutron flux at the sample position is 7 10 6 n/cm 2 s with a Cadmium ratio of 20/1.The gamma detector is a 50 % efficiency type p HPGe rounded by a NaI(Tl) for Compton suppressioning.The gamma spectra is measured through 0 to 8.5 MeV.The background have counting rate of 350 cps without sample. In this work is shown the efficiency curve, the calculed sensibilities and the lower detection limits for B, Cd, Sm, Gd, H, Cl, Hg, Eu, Ti, Ag, Au, Mo. The RA-6's PGNAA facility is fully working, although the analytic capacity is under improvement [es

  13. Efficient Multilevel and Multi-index Sampling Methods in Stochastic Differential Equations

    KAUST Repository

    Haji-Ali, Abdul Lateef

    2016-05-22

    of this thesis is the novel Multi-index Monte Carlo (MIMC) method which is an extension of MLMC in high dimensional problems with significant computational savings. Under reasonable assumptions on the weak and variance convergence, which are related to the mixed regularity of the underlying problem and the discretization method, the order of the computational complexity of MIMC is, at worst up to a logarithmic factor, independent of the dimensionality of the underlying parametric equation. We also apply the same multi-index methodology to another sampling method, namely the Stochastic Collocation method. Hence, the novel Multi-index Stochastic Collocation method is proposed and is shown to be more efficient in problems with sufficient mixed regularity than our novel MIMC method and other standard methods. Finally, MIMC is applied to approximate quantities of interest of stochastic particle systems in the mean-field when the number of particles tends to infinity. To approximate these quantities of interest up to an error tolerance, TOL, MIMC has a computational complexity of O(TOL-2log(TOL)2). This complexity is achieved by building a hierarchy based on two discretization parameters: the number of time steps in an Milstein scheme and the number of particles in the particle system. Moreover, we use a partitioning estimator to increase the correlation between two stochastic particle systems with different sizes. In comparison, the optimal computational complexity of MLMC in this case is O(TOL-3) and the computational complexity of Monte Carlo is O(TOL-4).

  14. KWIC Index to Government Publications

    Directory of Open Access Journals (Sweden)

    Margaret Norden

    2013-05-01

    Full Text Available United States and United Nations publications were not efficiently proc- essed nor readily available to the reader at Brandeis University Library. Data processing equipment was used to make a list of this material which could be referred to by a computer produced KWIC index. Currency and availability to the user, and time and cost efficiencies for the library were given precedence over detailed subject access. United States and United Nations classification schemes> and existing bibliographies and indexes were used extensively.

  15. Gamma-gamma directional correlations and coincidence studies in 154Gd

    International Nuclear Information System (INIS)

    Gupta, J.B.; Gupta, S.L.; Hamilton, J.H.; Ramayya, A.V.; Delhi Univ.

    1977-01-01

    The intensities, placements and E2/M1 mixing ratios of transitions in the decay of 154 Eu have been carefully studied to provide accurate data for microscopic calculations. Coincidence relationships in thhe decay of 154 Eu have been studied extensively with a multiparameter γ-γ coincidence system with two large volume Ge(Li) detectors. Spectra in coincidence with twenty energy gates were analyzed. Twenty-nine new coincidence relationships were established and confirmed most, but not all, of several levels previously assigned by energy fits only. From an analysis of coincidence spectra and singles spectra with a 18% efficiency Ge(Li) detector new information on the gamma-ray intensities were obtained. Precise values of the E2/M1 mixing ratios of transitions from the gamma- and beta-vibrational bands to the g.s. band have been determined from γ-γ directional correlation measurements with a NaI(Tl)-Ge(Li) detector coincidence system. Mixing ratios were obtained for a number of other transitions including those from KPI = 0 - and 2+ bands from direct and skipped cascade correlations. (orig.) [de

  16. Use of gamma probe in 131I thyroid uptake studies

    International Nuclear Information System (INIS)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of 131 I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of 131 I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  17. Impulsive and long duration high-energy gamma-ray emission from the very bright 2012 March 7 solar flares

    Energy Technology Data Exchange (ETDEWEB)

    Ajello, M. [Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720-7450 (United States); Albert, A.; Allafort, A.; Caliandro, G. A.; Cameron, R. A.; Charles, E. [W. W. Hansen Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology, Department of Physics and SLAC National Accelerator Laboratory, Stanford University, Stanford, CA 94305 (United States); Baldini, L. [Università di Pisa and Istituto Nazionale di Fisica Nucleare, Sezione di Pisa I-56127 Pisa (Italy); Barbiellini, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, I-34127 Trieste (Italy); Bastieri, D.; Buson, S. [Istituto Nazionale di Fisica Nucleare, Sezione di Padova, I-35131 Padova (Italy); Bellazzini, R.; Bregeon, J. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bissaldi, E. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, and Università di Trieste, I-34127 Trieste (Italy); Bonamente, E.; Cecchi, C. [Istituto Nazionale di Fisica Nucleare, Sezione di Perugia, I-06123 Perugia (Italy); Brandt, T. J. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Brigida, M. [Dipartimento di Fisica " M. Merlin" dell' Università e del Politecnico di Bari, I-70126 Bari (Italy); Bruel, P. [Laboratoire Leprince-Ringuet, École polytechnique, CNRS/IN2P3, Palaiseau (France); Buehler, R. [Deutsches Elektronen Synchrotron DESY, D-15738 Zeuthen (Germany); Caraveo, P. A., E-mail: nicola.omodei@stanford.edu, E-mail: vahep@stanford.edu, E-mail: melissa.pesce.rollins@pi.infn.it [INAF-Istituto di Astrofisica Spaziale e Fisica Cosmica, I-20133 Milano (Italy); and others

    2014-07-01

    The Fermi Large Area Telescope (LAT) detected gamma-rays up to 4 GeV from two bright X-class solar flares on 2012 March 7, showing both an impulsive and temporally extended emission phases. The gamma-rays appear to originate from the same active region as the X-rays associated with these flares. The >100 MeV gamma-ray flux decreases monotonically during the first hour (impulsive phase) followed by a slower decrease for the next 20 hr. A power law with a high-energy exponential cutoff can adequately describe the photon spectrum. Assuming that the gamma rays result from the decay of pions produced by accelerated protons and ions with a power-law spectrum, we find that the index of that spectrum is ∼3, with minor variations during the impulsive phase. During the extended phase the photon spectrum softens monotonically, requiring the proton index varying from ∼4 to >5. The >30 MeV proton flux observed by the GOES satellites also shows a flux decrease and spectral softening, but with a harder spectrum (index ∼2-3). Based on these observations, we explore the relative merits of prompt or continuous acceleration scenarios, hadronic or leptonic emission processes, and acceleration at the solar corona or by the fast coronal mass ejections. We conclude that the most likely scenario is continuous acceleration of protons in the solar corona that penetrate the lower solar atmosphere and produce pions that decay into gamma rays. However, acceleration in the downstream of the shock cannot be definitely ruled out.

  18. SU-F-T-294: The Analysis of Gamma Criteria for Delta4 Dosimetry Using Statistical Process Control

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S; Ahn, S; Kim, J; Park, K; Choi, W; Lee, H; Lee, E; Yoon, J; Keum, K [Yonsei Univeristy, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: To evaluate the sensitivity of gamma criteria for patient-specific volumetric modulated arc therapy(VMAT) quality assurance of the Delta{sup 4} dosimetry program using the statistical process control(SPC) methodology. Methods: The authors selected 20 patient-specific VMAT QA cases which were undertaken MapCHECK and ArcCHECK with gamma pass rate better than 97%. The QAs data were collected Delta4 Phantom+ and Elekta Agility six megavolts without using an angle incrementer. The gamma index(GI) were calculated in 2D planes with normalizing deviation to local dose(local gamma). The sensitivity of the GI methodology using criterion of 3%/3mm, 3%/2mm and 2%/3mm was analyzed with using process acceptability indices. We used local confidence(LC) level, the upper control limit(UCL) and lower control limit(LCL) of I-MR chart for process capability index(Cp) and a process acceptability index (Cpk). Results: The lower local confidence levels of 3%/3mm, 3%/2mm and 2%/3mm were 92.0%, 83.6% and 78.8% respectively. All of the calculated Cp and Cpk values that used LC level were under 1.0 in this study. The calculated LCLs of I-MR charts were 89.5%, 79.0% and 70.5% respectively. These values were higher than 1.0 which means good quality of QA. For the generally used lower limit of 90%, we acquired over 1.3 of Cp value for the gamma index of 3%/3mm and lower than 1.0 in the rest of GI. Conclusion: We applied SPC methodology to evaluate the sensitivity of gamma criteria and could see the lower control limits of VMAT QA for the Delta 4 dosimetry and could see that Delta 4 phantom+ dosimetry more affected by the position error and the I-MR chart derived values are more suitable for establishing lower limits. Acknowledgement: This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (No. 2015R1D1A1A01060463)

  19. SU-F-T-294: The Analysis of Gamma Criteria for Delta4 Dosimetry Using Statistical Process Control

    International Nuclear Information System (INIS)

    Cho, S; Ahn, S; Kim, J; Park, K; Choi, W; Lee, H; Lee, E; Yoon, J; Keum, K

    2016-01-01

    Purpose: To evaluate the sensitivity of gamma criteria for patient-specific volumetric modulated arc therapy(VMAT) quality assurance of the Delta 4 dosimetry program using the statistical process control(SPC) methodology. Methods: The authors selected 20 patient-specific VMAT QA cases which were undertaken MapCHECK and ArcCHECK with gamma pass rate better than 97%. The QAs data were collected Delta4 Phantom+ and Elekta Agility six megavolts without using an angle incrementer. The gamma index(GI) were calculated in 2D planes with normalizing deviation to local dose(local gamma). The sensitivity of the GI methodology using criterion of 3%/3mm, 3%/2mm and 2%/3mm was analyzed with using process acceptability indices. We used local confidence(LC) level, the upper control limit(UCL) and lower control limit(LCL) of I-MR chart for process capability index(Cp) and a process acceptability index (Cpk). Results: The lower local confidence levels of 3%/3mm, 3%/2mm and 2%/3mm were 92.0%, 83.6% and 78.8% respectively. All of the calculated Cp and Cpk values that used LC level were under 1.0 in this study. The calculated LCLs of I-MR charts were 89.5%, 79.0% and 70.5% respectively. These values were higher than 1.0 which means good quality of QA. For the generally used lower limit of 90%, we acquired over 1.3 of Cp value for the gamma index of 3%/3mm and lower than 1.0 in the rest of GI. Conclusion: We applied SPC methodology to evaluate the sensitivity of gamma criteria and could see the lower control limits of VMAT QA for the Delta 4 dosimetry and could see that Delta 4 phantom+ dosimetry more affected by the position error and the I-MR chart derived values are more suitable for establishing lower limits. Acknowledgement: This research was supported by Basic Science Research Program through the National Research Foundation of Korea(NRF) funded by the Ministry of Education (No. 2015R1D1A1A01060463)

  20. A field-deployable gamma-ray spectrometer utilizing xenon at high pressure

    International Nuclear Information System (INIS)

    Smith, G.C.; Mahler, G.J.; Yu, B.; Salwen, C.; Kane, W.R.; Lemley, J.R.

    1996-01-01

    Prototype gamma-ray spectrometers utilizing xenon gas at high pressure, suitable for applications in the nuclear safeguards, arms control, and nonproliferation communities, have been developed at Brookhaven National Laboratory (BNL). These spectrometers function as ambient-temperature ionization chambers detecting gamma rays with good efficiency in the energy range 50 keV - 2 MeV, with an energy resolution intermediate between semiconductor (Ge) and scintillation (NaI) spectrometers. They are capable of prolonged, low-power operation without a requirement for cryogenic fluids or other cooling mechanisms, and with the addition of small quantities of 3 He gas, can function simultaneously as efficient thermal neutron detectors

  1. Determination of correction factors for borehole natural gamma-ray measurements by Monte Carlo simulations

    NARCIS (Netherlands)

    Maucec, M.; Hendriks, Peter; Limburg, J.; de Meijer, R. J.

    2009-01-01

    The analysis of natural gamma-ray spectra measured in boreholes has to take into account borehole parameters such as the presence of casings and borehole diameter. For large, high-efficiency gamma-ray detectors, such as BGO-based systems, which employ full-spectrum data analysis, corresponding

  2. Modelling rainfall amounts using mixed-gamma model for Kuantan district

    Science.gov (United States)

    Zakaria, Roslinazairimah; Moslim, Nor Hafizah

    2017-05-01

    An efficient design of flood mitigation and construction of crop growth models depend upon good understanding of the rainfall process and characteristics. Gamma distribution is usually used to model nonzero rainfall amounts. In this study, the mixed-gamma model is applied to accommodate both zero and nonzero rainfall amounts. The mixed-gamma model presented is for the independent case. The formulae of mean and variance are derived for the sum of two and three independent mixed-gamma variables, respectively. Firstly, the gamma distribution is used to model the nonzero rainfall amounts and the parameters of the distribution (shape and scale) are estimated using the maximum likelihood estimation method. Then, the mixed-gamma model is defined for both zero and nonzero rainfall amounts simultaneously. The formulae of mean and variance for the sum of two and three independent mixed-gamma variables derived are tested using the monthly rainfall amounts from rainfall stations within Kuantan district in Pahang Malaysia. Based on the Kolmogorov-Smirnov goodness of fit test, the results demonstrate that the descriptive statistics of the observed sum of rainfall amounts is not significantly different at 5% significance level from the generated sum of independent mixed-gamma variables. The methodology and formulae demonstrated can be applied to find the sum of more than three independent mixed-gamma variables.

  3. What Can Simbol-X Do for Gamma-ray Binaries?

    Science.gov (United States)

    Cerutti, B.; Dubus, G.; Henri, G.; Hill, A. B.; Szostek, A.

    2009-05-01

    Gamma-ray binaries have been uncovered as a new class of Galactic objects in the very high energy sky (>100 GeV). The three systems known today have hard X-ray spectra (photon index ~1.5), extended radio emission and a high luminosity in gamma-rays. Recent monitoring campaigns of LSI +61°303 in X-rays have confirmed variability in these systems and revealed a spectral hardening with increasing flux. In a generic one-zone leptonic model, the cooling of relativistic electrons accounts for the main spectral and temporal features observed at high energy. Persistent hard X-ray emission is expected to extend well beyond 10 keV. We explain how Simbol-X will constrain the existing models in connection with Fermi Space Telescope measurements. Because of its unprecedented sensitivity in hard X-rays, Simbol-X will also play a role in the discovery of new gamma-ray binaries, giving new insights into the evolution of compact binaries.

  4. What Can Simbol-X Do for Gamma-ray Binaries?

    International Nuclear Information System (INIS)

    Cerutti, B.; Dubus, G.; Henri, G.; Hill, A. B.; Szostek, A.

    2009-01-01

    Gamma-ray binaries have been uncovered as a new class of Galactic objects in the very high energy sky (>100 GeV). The three systems known today have hard X-ray spectra (photon index ∼1.5), extended radio emission and a high luminosity in gamma-rays. Recent monitoring campaigns of LSI +61 deg. 303 in X-rays have confirmed variability in these systems and revealed a spectral hardening with increasing flux. In a generic one-zone leptonic model, the cooling of relativistic electrons accounts for the main spectral and temporal features observed at high energy. Persistent hard X-ray emission is expected to extend well beyond 10 keV. We explain how Simbol-X will constrain the existing models in connection with Fermi Space Telescope measurements. Because of its unprecedented sensitivity in hard X-rays, Simbol-X will also play a role in the discovery of new gamma-ray binaries, giving new insights into the evolution of compact binaries.

  5. Study of the effect of the gamma radiation in polycarbonate

    International Nuclear Information System (INIS)

    Khoury, H.J.; Araujo, E.S. de; Silveira, S.V. da

    1990-01-01

    To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with 60 Co gamma beam with doses between 0,2KGy and 50KGy. The results obtained shown variations in the yellowed index above 1KGy dose. Their mechanical proprieties are not changed at interval of this doses. (author) [pt

  6. Nature of gamma rays background radiation in new and old buildings of Qatar University

    International Nuclear Information System (INIS)

    Al-Houty, L.; Abou-Leila, H.; El-Kameesy, S.

    1987-01-01

    Measurements and analysis of gamma-background radiation spectrum in four different places of Qatar University campus were performed at the energy range 10 keV-3 MeV using hyper pure Ge-detector. The dependence of the detector absolute photopeak efficiency on gamma-ray energies was determined and correction of the data for that was also done. The absorbed dose for each gamma line was calculated and an estimation of the total absorbed dose for the detected gamma lines in the four different places was obtained. Comparison with other results was also performed

  7. Performance analysis of a threshold-based parallel multiple beam selection scheme for WDM-based systems for Gamma-Gamma distributions

    KAUST Repository

    Nam, Sung Sik

    2017-03-02

    In this paper, we statistically analyze the performance of a threshold-based parallel multiple beam selection scheme (TPMBS) for Free-space optical (FSO) based system with wavelength division multiplexing (WDM) in cases where a pointing error has occurred for practical consideration over independent identically distributed (i.i.d.) Gamma-Gamma fading conditions. Specifically, we statistically analyze the characteristics in operation under conventional heterodyne detection (HD) scheme for both adaptive modulation (AM) case in addition to non-AM case (i.e., coherentnon-coherent binary modulation). Then, based on the statistically derived results, we evaluate the outage probability (CDF) of a selected beam, the average spectral efficiency (ASE), the average number of selected beams (ANSB), and the average bit error rate (BER). Some selected results shows that we can obtain the higher spectral efficiency and simultaneously reduce the potential increasing of the complexity of implementation caused by applying the selection based beam selection scheme without a considerable performance loss.

  8. The probability distribution model of air pollution index and its dominants in Kuala Lumpur

    Science.gov (United States)

    AL-Dhurafi, Nasr Ahmed; Razali, Ahmad Mahir; Masseran, Nurulkamal; Zamzuri, Zamira Hasanah

    2016-11-01

    This paper focuses on the statistical modeling for the distributions of air pollution index (API) and its sub-indexes data observed at Kuala Lumpur in Malaysia. Five pollutants or sub-indexes are measured including, carbon monoxide (CO); sulphur dioxide (SO2); nitrogen dioxide (NO2), and; particulate matter (PM10). Four probability distributions are considered, namely log-normal, exponential, Gamma and Weibull in search for the best fit distribution to the Malaysian air pollutants data. In order to determine the best distribution for describing the air pollutants data, five goodness-of-fit criteria's are applied. This will help in minimizing the uncertainty in pollution resource estimates and improving the assessment phase of planning. The conflict in criterion results for selecting the best distribution was overcome by using the weight of ranks method. We found that the Gamma distribution is the best distribution for the majority of air pollutants data in Kuala Lumpur.

  9. Effects of gamma radiation in mechanical and optical properties of polycarbonate

    International Nuclear Information System (INIS)

    Araujo, E.S.; Khoury, H.J.; Silveira, S.V. da; Dallolio, A.

    1990-01-01

    The polycarbonates are used in different industrial applications due to their excellent dielectric proprieties, impact resistance and high temperature resistance. For some of this applications, the polycarbonates are exposed to gamma radiation which produces a molecular scission, occasioning changes in the polycarbonate proprieties. To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with sup(60)Co gamma beam with doses between 0,2kGy and 50kGy. The results obtained shown variations in the yellowness index above 1kGy dose. Their mechanical proprieties are not changed in the above dose interval. (author)

  10. Gamma ray doses proceeding from natural occurring radionuclides in closed environments

    International Nuclear Information System (INIS)

    Aguiar, Vitor Angelo P. de; Medina, Nilberto H.; Silveira, Marcilei A. Guazzelli da; Moreira, Ramon H.

    2009-01-01

    In this work we report on the application of gamma-ray spectrometry in the study of the effective dose coming from terrestrial natural elements present in building materials such as sand, cement, lime (CaO) and milled granitic stones. The major contribution to annual gamma-ray radiation effective dose is due to the natural occurring radionuclides 40 K, 232 Th and 238 U. Two spectrometry systems were employed to measure the gamma radiation: one with a 60% efficient GeHP detector and the second one with a 2''x2'' NaI(Tl) scintillator. The estimated effective dose coming from the three reference rooms assumed is 0.63 mSv/yr, proceeding from terrestrial natural elements. The principal gamma radiation sources are cement, sand and bricks. (author)

  11. Study of the functional characteristics of a NaI(Tl) scintillator gamma spectrometer

    International Nuclear Information System (INIS)

    Jesus Barbosa, S. de.

    1983-01-01

    Functional characteristics (resolution, stability, linearity, counting efficiency) of a NaI(Tl) scintillator gamma spectrometer were studied. Diagrams were plotted and several standard sources ( 241 Am, 109 Cd, 57 Co, 137 Cs, 54 Mn, 22 Na) with gamma energies ranging from 60 to 1275 KeV were used. (C.L.B.) [pt

  12. Labeling of human immune gamma globulin with sup(99m)Tc

    International Nuclear Information System (INIS)

    Wong, D.W.; Huang, J.T.

    1977-01-01

    Human immune serum gamma globulin and rabbit anti-Stap. aureus antibody have been successfully labeled with sup(99m)Tc at pH 7.4 with an average binding efficiency of 86 and 82%, respectively. The labeled proteins behave similarly to unlabeled gamma-globulin fraction in the normal human serum as demonstrated by protein electrophoresis. The biological half-time of sup(99m)Tc-gamma-globulin in dog has been determined to be 54 min for the fast component and 14.7 hr for a slower component. Immunological assays demonstrate no significant change in antibody activity after labeling process. (author)

  13. [Analog gamma camera digitalization computer system].

    Science.gov (United States)

    Rojas, G M; Quintana, J C; Jer, J; Astudillo, S; Arenas, L; Araya, H

    2004-01-01

    Digitalization of analogue gamma cameras systems, using special acquisition boards in microcomputers and appropriate software for acquisition and processing of nuclear medicine images is described in detail. Microcomputer integrated systems interconnected by means of a Local Area Network (LAN) and connected to several gamma cameras have been implemented using specialized acquisition boards. The PIP software (Portable Image Processing) was installed on each microcomputer to acquire and preprocess the nuclear medicine images. A specialized image processing software has been designed and developed for these purposes. This software allows processing of each nuclear medicine exam, in a semiautomatic procedure, and recording of the results on radiological films. . A stable, flexible and inexpensive system which makes it possible to digitize, visualize, process, and print nuclear medicine images obtained from analogue gamma cameras was implemented in the Nuclear Medicine Division. Such a system yields higher quality images than those obtained with analogue cameras while keeping operating costs considerably lower (filming: 24.6%, fixing 48.2% and developing 26%.) Analogue gamma camera systems can be digitalized economically. This system makes it possible to obtain optimal clinical quality nuclear medicine images, to increase the acquisition and processing efficiency, and to reduce the steps involved in each exam.

  14. Gasdynamics of relativistically expanding gamma-ray burst sources - Kinematics, energetics, magnetic fields, and efficiency

    Science.gov (United States)

    Meszaros, P.; Laguna, P.; Rees, M. J.

    1993-01-01

    We calculate both analytically and numerically the evolution of highly relativistic fireballs through the stages of free expansion and coasting, and determine the dependence of the thermodynamic and radiation variables in the comoving and laboratory flames. The dynamics and the comoving geometry change at the (lab) expansion factors r/r(0) greater than eta and r/r(0) greater than eta-squared, respectively, where eta = E(0)/M(0)c-squared is the initial Lorentz factor. In the lab, the gas appears concentrated in a thin shell of width r(0) until r/r(0) of less than about eta-squared, and increases linearly after that. Magnetic fields may have been important in the original impulsive event. We discuss their effect on the fireball dynamics and also consider their effects on the radiation emitted when the fireball runs into an external medium and is decelerated. The inverse synchro-Compton mechanism can then yield high radiative efficiency in the reverse shock (and through turbulent instabilities and mixing also in the forward blast wave), producing a burst of nonthermal radiation mainly in the MeV to GeV range. The energy and duration depend on eta, the magnetic field strength, and the external density, and can match the range of properties observed in cosmic gamma-ray bursts.

  15. A Versatile and Efficient GPU Data Structure for Spatial Indexing

    KAUST Repository

    Schneider, Jens

    2016-08-10

    In this paper we present a novel GPU-based data structure for spatial indexing. Based on Fenwick trees—a special type of binary indexed trees—our data structure allows construction in linear time. Updates and prefixes can be computed in logarithmic time, whereas point queries require only constant time on average. Unlike competing data structures such as summed-area tables and spatial hashing, our data structure requires a constant amount of bits for each data element, and it offers unconstrained point queries. This property makes our data structure ideally suited for applications requiring unconstrained indexing of large data, such as block-storage of large and block-sparse volumes. Finally, we provide asymptotic bounds on both run-time and memory requirements, and we show applications for which our new data structure is useful.

  16. A Versatile and Efficient GPU Data Structure for Spatial Indexing

    KAUST Repository

    Schneider, Jens; Rautek, Peter

    2016-01-01

    In this paper we present a novel GPU-based data structure for spatial indexing. Based on Fenwick trees—a special type of binary indexed trees—our data structure allows construction in linear time. Updates and prefixes can be computed in logarithmic time, whereas point queries require only constant time on average. Unlike competing data structures such as summed-area tables and spatial hashing, our data structure requires a constant amount of bits for each data element, and it offers unconstrained point queries. This property makes our data structure ideally suited for applications requiring unconstrained indexing of large data, such as block-storage of large and block-sparse volumes. Finally, we provide asymptotic bounds on both run-time and memory requirements, and we show applications for which our new data structure is useful.

  17. Image Vector Quantization codec indexes filtering

    Directory of Open Access Journals (Sweden)

    Lakhdar Moulay Abdelmounaim

    2012-01-01

    Full Text Available Vector Quantisation (VQ is an efficient coding algorithm that has been widely used in the field of video and image coding, due to its fast decoding efficiency. However, the indexes of VQ are sometimes lost because of signal interference during the transmission. In this paper, we propose an efficient estimation method to conceal and recover the lost indexes on the decoder side, to avoid re-transmitting the whole image again. If the image or video has the limitation of a period of validity, re-transmitting the data wastes the resources of time and network bandwidth. Therefore, using the originally received correct data to estimate and recover the lost data is efficient in time-constrained situations, such as network conferencing or mobile transmissions. In nature images, the pixels are correlated with their neighbours and VQ partitions the image into sub-blocks and quantises them to the indexes that are transmitted; the correlation between adjacent indexes is very strong. There are two parts of the proposed method. The first is pre-processing and the second is an estimation process. In pre-processing, we modify the order of codevectors in the VQ codebook to increase the correlation among the neighbouring vectors. We then use a special filtering method in the estimation process. Using conventional VQ to compress the Lena image and transmit it without any loss of index can achieve a PSNR of 30.429 dB on the decoder. The simulation results demonstrate that our method can estimate the indexes to achieve PSNR values of 29.084 and 28.327 dB when the loss rate is 0.5% and 1%, respectively.

  18. Testing for Environmental Kuznets Curve in the EU Agricultural Sector through an Eco-(inEfficiency Index

    Directory of Open Access Journals (Sweden)

    George Vlontzos

    2017-12-01

    Full Text Available Studies on agricultural production practices advance within international literature and new methods are proposed in order to assess the agricultural sustainability, either at farm or macro level. The present paper builds on these advancements and develops a synthetic Eco-(inefficiency index by employing a directional distance function—data envelopment analysis (DEA model. This index is used in order to assess the sustainability of the EU agricultural sector for the period 1999–2012 on a country level. Furthermore, Eco-(inefficiency, together with the energy use and greenhouse gas (GHG emissions are regressed on the gross domestic product (GDP of EU countries, in order to check for any environmental Kuznets curve relationship existence. Results signify that efficiency improvements are possible, both towards output development and GHG emissions reduction. In addition, the potential of each country in adopting more sustainable production practices is not totally connected with its economic development, as Eco-(inefficiency and GDP levels of EU countries seem to be linked with an N-Shaped curve.

  19. New determinations of gamma-ray line intensities of the E{sub p}=550 and 1747 keV resonances of the {sup 13}C(p,{gamma}){sup 14}N reaction

    Energy Technology Data Exchange (ETDEWEB)

    Kiener, J. E-mail: kiener@csnsm.in2p3.fr; Gros, M.; Tatischeff, V.; Attie, D.; Bailly, I.; Bauchet, A.; Chapuis, C.; Cordier, B.; Deloncle, I.; Porquet, M.G.; Schanne, S.; Sereville, N. de; Tauzin, G

    2004-03-01

    Gamma-ray angular distributions for the resonances at E{sub p}=550 and 1747 keV of the radiative capture reaction {sup 13}C(p,{gamma}){sup 14}N have been measured, using intense proton beams on isotopically pure {sup 13}C targets. Experimental gamma-ray spectra were obtained with three HP-Germanium detectors at four angles for E{sub p}=550 keV and six angles for E{sub p}=1747 keV in the range of 0-90 deg. with respect to the proton beam. From the data, relative intensities for the strongest transitions were extracted with an accuracy of typically 5%, making these resonances new useful gamma-ray standards for efficiency calibration in the energy range from E{sub {gamma}}=1.6-9 MeV. Gamma-ray branching ratios were obtained for several levels of {sup 14}N and are compared with literature values.

  20. Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energies

    International Nuclear Information System (INIS)

    Szymanska, K.; Achenbach, P.; Agnello, M.; Botta, E.; Bracco, A.; Bressani, T.; Camera, F.; Cederwall, B.; Feliciello, A.; Ferro, F.; Gerl, J.; Iazzi, F.; Kavatsyuk, M.; Kojouharov, I.; Pochodzalla, J.; Raciti, G.; Saito, T.R.; Sanchez Lorente, A.; Tegner, P.-E.; Wieland, O.

    2008-01-01

    The use of High Purity Germanium detectors (HPGe) has been planned in some future experiments of hadronic physics. The crystals will be located close to large spectrometers where the magnetic fringing field will not be negligible and their performances might change. Moreover high precision is required in these experiments. The contribution of magnetic field presence and long term measurements is unique. In this paper the results of systematic measurements of the resolution, stability and efficiency of a crystal operating inside a magnetic field of 0.8 T, using radioactive sources in the energy range from 0.08 to 1.33 MeV, are reported. The measurements have been repeated during several months in order to test if any permanent damage occurred. The resolution at 1.117 and 1.332 MeV gamma-rays from a 60 Co source has been measured at different magnetic fields in the range of 0-0.8 T and the results are compared with the previous data

  1. Study of operational systems of gamma spectrometry systems

    International Nuclear Information System (INIS)

    Melo, M.C. de.

    1985-07-01

    The application of gamma spectrometers is tantamount to the perfect knowledge of their operational characteristics. Thus a study of the most significant characteristics (stability, linearity of response, energy resolution and peak efficiency) was carried out with an NaI(T1) and an (HP)Ge systems. Gamma standards with an energy range of 60 to 1300 KeV were used. Simple numerical methods were applied to the data, and the Behaviour of each system, with regard to the aforementioned characteristics, was observed for several operation voltages. It was evident the superiority of the (HP)Ge system in stability, linearity and resolution, whereas the NaI(T1) system showed a greater efficiency. The results obtained for each system were consistent with the ones found elsewhere, so that it may be concluded that both are working properly, and that the methodology proposed herein is appropriate for the test of such equipments [pt

  2. Alteration of Leaf Anatomy of Handeuleum (Graptophyllum pictum L. Griff due to Gamma Irradiation

    Directory of Open Access Journals (Sweden)

    Arrin Rosmala

    2016-07-01

    Full Text Available The leaves of the plant handeuleum (Graptophyllum pictum L. Griff have long been used for traditional medicine in several regions in Indonesia. This study was aimed to determine the effect of gamma irradiation rate on the anatomy and phytochemical content of the leaf. The rates of gamma rays used were 0, 15, 30, 45, 60, 75, 90, and 105 Gy. Our results showed that gamma ray irradiation rate of 30 Gy produced leaves that contain anthocyanins and carotenoids, with the highest number of stomata and stomatal density compared with control plants. Stomatal index was found highest in the leaves with 45 Gy of gamma irradiation. High-rate gamma ray irradiation produced rigid, thick, and frangible leaves. A high rate of gamma irradiation, i.e. 75, 90, and 105 Gy, produces bigger palisade, sponges, and upper epidermis than the control plants, respectively. Our results showed an association between increasing rate of irradiation with alterations in the structure of leaf anatomy and phytochemical content of handeuleum.

  3. Performance characteristics of high resolution semiconductor gamma ray spectrometry system

    Energy Technology Data Exchange (ETDEWEB)

    Naing, Ko Ko

    1994-05-01

    A high purity germanium (HPGe) gamma-ray detector has been used in Nuclear Research Laboratory, Department of Physics, Yangon University for over fourteen years. Now it is still being used and it is coupled to new peripheral devices, such as spectroscopy amplifier, analog to digital converter and computer fit-in S-100 multichannel analyser. Therefore, it is necessary to determine the important parameters: energy resolution, detecting efficiency and relative efficiency of the system. In the present work, these parameters were obtained by using mixed calibrated source. The results were compared to the data given by the manufacturer. Moreover, the parameters of another {gamma}-ray detecting system NaI(T1) were also determined. In conclusion the results obtained from the above two measurements were compared and discussed

  4. Analyzing power of AGATA triple clusters for gamma-ray linear polarization

    Energy Technology Data Exchange (ETDEWEB)

    Bizzeti, P.G.; Sona, P.; Melon, B.; Bizzeti-Sona, A.M.; Perego, A. [Universita di Firenze, Dipartimento di Fisica, Firenze (Italy); INFN, Firenze (Italy); Michelagnoli, C.; Lunardi, S.; Mengoni, D.; Recchia, F. [INFN, Padova (Italy); Universita di Padova, Dipartimento di Fisica, Padova (Italy); Bazzacco, D.; Farnea, E.; Menegazzo, R.; Ur, C.A. [INFN, Padova (Italy); De Angelis, G.; Gottardo, A.; Napoli, D.R.; Sahin, E.; Valiente-Dobon, J.J. [Laboratori Nazionali di Legnaro, INFN, Padova (Italy); Gadea, A. [University of Valencia, IFIC, CSIC, Valencia (Spain); Nannini, A. [INFN, Firenze (Italy)

    2015-04-01

    We have investigated the ability of AGATA triple clusters to measure the linear polarization of gamma rays, exploiting the azimuthal-angle dependence of the Compton scattering differential cross section. To this aim, partially polarized gamma rays have been produced by Coulomb excitation of the first excited state of {sup 104}Pd and {sup 108}Pd, which decay to the ground state by emission of gamma rays of 555.8 keV and 433.9 keV, respectively. Pulse-shape analysis and gamma-ray tracking techniques have been used to determine the position and time sequence of the interaction points inside the germanium crystals. Anisotropies in the detection efficiency have been taken into account using 661.6 keV gammas from a {sup 137}Cs radioactive source. We obtain an average analyzing power of 0.451(34) at 433.9 keV and 0.484(24) at 555.8 keV. (orig.)

  5. 3rd Interplanetary Network Gamma-Ray Burst Website

    Science.gov (United States)

    Hurley, Kevin

    1998-05-01

    We announce the opening of the 3rd Interplanetary Network web site at http://ssl.berkeley.edu/ipn3/index.html This site presently has four parts: 1. A bibliography of over 3000 publications on gamma-ray bursts, 2. IPN data on all bursts triangulated up to February 1998, 3. A master list showing which spacecraft observed which bursts, 4. Preliminary IPN data on the latest bursts observed.

  6. Pricing the property claim service (PCS) catastrophe insurance options using gamma distribution

    Science.gov (United States)

    Noviyanti, Lienda; Soleh, Achmad Zanbar; Setyanto, Gatot R.

    2017-03-01

    The catastrophic events like earthquakes, hurricanes or flooding are characteristics for some areas, a properly calculated annual premium would be closely as high as the loss insured. From an actuarial perspective, such events constitute the risk that are not insurable. On the other hand people living in such areas need protection. In order to securitize the catastrophe risk, futures or options based on a loss index could be considered. Chicago Board of Trade launched a new class of catastrophe insurance options based on new indices provided by Property Claim Services (PCS). The PCS-option is based on the Property Claim Service Index (PCS-Index). The index are used to determine and payout in writing index-based insurance derivatives. The objective of this paper is to price PCS Catastrophe Insurance Option based on PCS Catastrophe index. Gamma Distribution is used to estimate PCS Catastrophe index distribution.

  7. Differential androgenesis in gamma irradiated mice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jihyang; Yoon, Yongdal [Hanyang Univ., Seoul (Korea, Republic of); Kim, Jin Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2002-07-01

    The Leydig cells of the testis account for at least 75% of the total testosterone produced in the normal adult male. Whereas the production of estrogen from androgen is catalyzed by aromatase cytochrome P450, which is found in many tissues, including gonad, brain, adipose tissue, bone, and heart. The gamma-irradiation causes the impairment of spermatogenesis and steroidogenesis in male mice. The present study was performed to analyze changes in testosterone concentrations and expression of steroidogenic enzyme of mice after whole body gamma-irradiation. Eight-week-old male ICR mice were irradiated with 6.5 or 10 Gy. At days 1, 2, 3, 4, and 5 after irradiation, testes were removed and processed for paraffin sections and isolation of mRNA. We calculated the gonad index from body and testis weight, and checked the testis volume. Hormonal analysis was performed by means of radioimmunoassay (RIA) in serum and intratesticular fluid. Semiquantitative reverse transcription polymerase chain reaction (RT-PCR) was used to evaluate the expression kinetics of the apoptotic gene and the cytochrome P450 aromatase gene after irradiation. In gamma-irradiated mice, the body weight reduced in comparison to that of the control group. Therefore, gonad indices increased. The testosterone concentrations in serum and intratesticular fluid were significantly reduced. RT- PCR data represented that the expression of Fas, Fas ligand, and aromatase cytochrome P450 showed the specific patterns against control groups. These results indicated that gamma- irradiation of adult mice induced the alteration of androgenesis and suggested that might counteract the spermatogenesis.

  8. Multi-messenger Light Curves from Gamma-Ray Bursts in the Internal Shock Model

    Energy Technology Data Exchange (ETDEWEB)

    Bustamante, Mauricio [Center for Cosmology and AstroParticle Physics (CCAPP), The Ohio State University, Columbus, OH 43210 (United States); Heinze, Jonas; Winter, Walter [Deutsches Elektronen-Synchrotron (DESY), Platanenallee 6, D-15738 Zeuthen (Germany); Murase, Kohta, E-mail: bustamanteramirez.1@osu.edu, E-mail: walter.winter@desy.de, E-mail: jonas.heinze@desy.de, E-mail: murase@psu.edu [Center for Particle and Gravitational Astrophysics, The Pennsylvania State University, University Park, PA16802 (United States)

    2017-03-01

    Gamma-ray bursts (GRBs) are promising as sources of neutrinos and cosmic rays. In the internal shock scenario, blobs of plasma emitted from a central engine collide within a relativistic jet and form shocks, leading to particle acceleration and emission. Motivated by present experimental constraints and sensitivities, we improve the predictions of particle emission by investigating time-dependent effects from multiple shocks. We produce synthetic light curves with different variability timescales that stem from properties of the central engine. For individual GRBs, qualitative conclusions about model parameters, neutrino production efficiency, and delays in high-energy gamma-rays can be deduced from inspection of the gamma-ray light curves. GRBs with fast time variability without additional prominent pulse structure tend to be efficient neutrino emitters, whereas GRBs with fast variability modulated by a broad pulse structure can be inefficient neutrino emitters and produce delayed high-energy gamma-ray signals. Our results can be applied to quantitative tests of the GRB origin of ultra-high-energy cosmic rays, and have the potential to impact current and future multi-messenger searches.

  9. Multi-messenger light curves from gamma-ray bursts in the internal shock model

    Energy Technology Data Exchange (ETDEWEB)

    Bustamante, Mauricio [Ohio State Univ., Columbus, OH (United States). Center for Cosmology and AstroParticle Physics (CCAPP); Ohio State Univ., Columbus, OH (United States). Dept. of Physics; Murase, Kohta [Pennsylvania State Univ., University Park, PA (United States). Center for Particle and Gravitational Astrophysics; Pennsylvania State Univ., University Park, PA (United States). Dept. of Astronomy and Astrophysics; Winter, Walter [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2016-06-15

    Gamma-ray bursts (GRBs) are promising as sources of neutrinos and cosmic rays. In the internal shock scenario, blobs of plasma emitted from a central engine collide within a relativistic jet and form shocks, leading to particle acceleration and emission. Motivated by present experimental constraints and sensitivities, we improve the predictions of particle emission by investigating time-dependent effects from multiple shocks. We produce synthetic light curves with different variability timescales that stem from properties of the central engine. For individual GRBs, qualitative conclusions about model parameters, neutrino production efficiency, and delays in high-energy gamma rays can be deduced from inspection of the gamma-ray light curves. GRBs with fast time variability without additional prominent pulse structure tend to be efficient neutrino emitters, whereas GRBs with fast variability modulated by a broad pulse structure tend to be inefficient neutrino emitters and produce delayed high-energy gamma-ray signals. Our results can be applied to quantitative tests of the GRB origin of ultra-high-energy cosmic rays, and have the potential to impact current and future multi-messenger searches.

  10. Perubahan Morfologi dan Pertumbuhan Handeuleum (Graptophyllum pictum L. Griff akibat Iradiasi Sinar Gamma

    Directory of Open Access Journals (Sweden)

    Arrin Rosmala

    2016-02-01

    Full Text Available ABSTRACTHandeuleum (Graptophyllum pictum L.Griff is a medicinal plant widely used as a traditional medicine due to its benefecial content. Therefore, it should be developed as one of the leading Indonesian medicinal plants. The purpose of this research was to study the effect of gamma ray irradiation on morphological alteration and growth of Handeuleum accession from Bogor. The doses of gamma rays were 0, 15, 30, 45, 60, 75, 90, and 105 Gy. The results of the research showed that gamma-ray irradiation induced morphological changes and influences the growth of Handeuleum. Irradiation dose at rate of 105 Gy produced new leaf morphology in Handeuleum, namely cordate. Doses of 60, 75, 90, and 105 Gy produce stunted plants with stiff and yellowish-green leaves. The dose of 45 Gy produced relative green color index which was higher than the control plants.Keywords: handeuleum, gamma irradiations

  11. Gamma ray beam transmutation

    International Nuclear Information System (INIS)

    Imasaki, K.; Li, D.; Miyamoto, S.; Amano, S.; Motizuki, T.

    2007-01-01

    We have proposed a new approach to nuclear transmutation by a gamma ray beam of Compton scattered laser photon. We obtained 20 MeV gamma ray in this way to obtain transmutation rates with the giant resonance of 1 97Au and 1 29Iodine. The rate of the transmutation agreed with the theoretical calculation. Experiments on energy spectrum of positron, electron and neutron from targets were performed for the energy balance and design of the system scheme. The reaction rate was about 1.5∼4% for appropriate photon energies and neutron production rate was up to 4% in the measurements. We had stored laser photon more than 5000 times in a small cavity which implied for a significant improvement of system efficiency. Using these technologies, we have designed an actual transmutation system for 1 29Iodine which has a 16 million year's activity. In my presentation, I will address the properties of this scheme, experiments results and transmutation system for iodine transmutation

  12. Disinfection of water and wastewater of Isfahan water and wastewater treatment plants by gamma irradiation

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Amin

    2013-01-01

    Conclusion: At gamma doses used in this study, the coliforms were removed completely. But for wastewater samples, although the removal efficiencies were above 80%, the environmental standards related to microbial parameters were not satisfied. Therefore, it is necessary to use higher doses of gamma radiation.

  13. Sterilization of Carriers by using Gamma Irradiation for Bio fertilizer Inoculum Production

    International Nuclear Information System (INIS)

    Tittabutr, Panlada; Teamtisong, Kamonluck; Pewlong, Wachiraporn; Teaumroong, Neuhg; Laoharojanaphand, Sirinart; Boonkerd, Nantakorn

    2009-07-01

    Full text: Gamma irradiation has been widely used in sterilization process, which leads to improvement in the quality of the products. In the case of bio fertilizer inoculum, the sterilized carrier is also needed for producing high quality bio fertilizer. This study aimed at determining the factors, such as carrier materials, moistures, and packing sizes including packaging materials that may affect the sterilization efficiency by using gamma irradiation. All carrier materials, peat and compost, could be efficiently sterilized by irradiation. The carriers that have moisture content lower than 20% could be sterilized by irradiation at 15 kGy, while carrier with 30% moisture content must be sterilized by irradiation at 25 kGy. Higher irradiation dose was also necessary for sterilization of bigger carrier packing sizes. For, packaging materials, polyethylene bag appeared most durable after gamma irradiation even at high doses. However, contaminants could be detected in irradiated carrier after storage at room temperature for two months. It was hypothesized that these contaminants are spore forming microorganisms, which resist gamma irradiation. This hypothesis, as well as the quality of bio fertilizer produced from irradiated carrier, will be further evaluated

  14. ECONOMETRIC’S MODEL: THE DEPENDENCE OF PFTS INDEX FROM ECONOMICS RANKS

    OpenAIRE

    K. Cherkashyna

    2013-01-01

    Dynamics of stock index is an indicator of market efficiency. We use the strong form of market efficiency, where prices reflect all available information, – both public and private. National index PFTS and main world indexes such as Dow Jones industrial, Standard & Poor’s 500, Nasdaq composite, Japan’s Nikkei index, Hong Kong’s Hang Seng index are very volatility. Last week all of the major U.S. stock indexes were in the red. Data dependence index PFTS from many exogenous and internal factors...

  15. Gamma-irradiation effects on optical properties of lexan film. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Abd-Elrehim, N; El-Samahy, A E; Kassem, M E [Physics Department, Faculty of Science, Alexandria University. (Egypt); Abou-Taleb, W M [Physics and Chemistry Department, Faculty of Education, Alexandria University. (Egypt)

    1996-03-01

    The optical absorption method is a powerful tool for studying the optically induced transitions and for determining the energy gap in crystalline and non-crystalline materials. The absorption spectra in the lower energy part sheds light on the atomic vibrations. While the higher energy parts of the spectrum manifest the electronic states in the atoms. Effect of gamma-irradiation on the optical properties of plastic detector (Lexan film) has been studied. These investigations were carried out for gamma-doses from 10 kGy -2 mGy to determine the optical parameters; optical energy gap E{sub op}, absorption coefficient {alpha} , absorption index K, mobility energy gap E{sub g}, absorption band edge {lambda}{sub g} and the absorbance at wavelength 340 nm. The results showed that both direct and indirect transitions existed in lexan detector, and because highly sensitive to gamma-irradiation doses. The variations of optical energy gap with gamma-irradiation doses can be explained as the change in the degree of disorder and the phonon energy E{sub p}, is dose dependent. 7 figs.

  16. Gamma-irradiation effects on optical properties of lexan film. Vol. 2

    International Nuclear Information System (INIS)

    Abd-Elrehim, N.; El-Samahy, A.E.; Kassem, M.E.; Abou-Taleb, W.M.

    1996-01-01

    The optical absorption method is a powerful tool for studying the optically induced transitions and for determining the energy gap in crystalline and non-crystalline materials. The absorption spectra in the lower energy part sheds light on the atomic vibrations. While the higher energy parts of the spectrum manifest the electronic states in the atoms. Effect of gamma-irradiation on the optical properties of plastic detector (Lexan film) has been studied. These investigations were carried out for gamma-doses from 10 kGy -2 mGy to determine the optical parameters; optical energy gap E op , absorption coefficient α , absorption index K, mobility energy gap E g , absorption band edge λ g and the absorbance at wavelength 340 nm. The results showed that both direct and indirect transitions existed in lexan detector, and because highly sensitive to gamma-irradiation doses. The variations of optical energy gap with gamma-irradiation doses can be explained as the change in the degree of disorder and the phonon energy E p , is dose dependent. 7 figs

  17. Study of the $e^+ e^- \\to Z\\gamma\\gamma \\to q\\overline{q}\\gamma\\gamma$ Process at LEP

    CERN Document Server

    Acciarri, M.; Adriani, O.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Ambrosi, G.; Anderhub, H.; Andreev, Valery P.; Angelescu, T.; Anselmo, F.; Arefev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, L.; Balandras, A.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Batalova, N.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Bhattacharya, S.; Biasini, M.; Biglietti, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Buffini, A.; Buijs, A.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.M.; Casaus, J.; Castellini, G.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y.H.; Chaturvedi, U.K.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Csilling, A.; Cucciarelli, S.; Dai, T.S.; van Dalen, J.A.; D'Alessandro, R.; de Asmundis, R.; Deglon, P.; Degre, A.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; van Dierendonck, D.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dova, M.T.; Duchesneau, D.; Dufournaud, D.; Duinker, P.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Erne, F.C.; Ewers, A.; Extermann, P.; Fabre, M.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gau, S.S.; Gentile, S.; Gheordanescu, N.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; van Gulik, R.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hasan, A.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hidas, P.; Hirschfelder, J.; Hofer, H.; Holzner, G.; Hoorani, H.; Hou, S.R.; Hu, Y.; Iashvili, I.; Jin, B.N.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Khan, R.A.; Kafer, D.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, D.; Kim, J.K.; Kirkby, Jasper; Kiss, D.; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopal, M.; Kopp, A.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Krenz, W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, H.J.; Le Goff, J.M.; Leiste, R.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Lubelsmeyer, K.; Luci, C.; Luckey, David; Lugnier, L.; Luminari, L.; Lustermann, W.; Ma, W.G.; Maity, M.; Malgeri, L.; Malinin, A.; Mana, C.; Mangeol, D.; Mans, J.; Marian, G.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; von der Mey, M.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Moulik, T.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niessen, T.; Nisati, A.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Oulianov, A.; Palomares, C.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Paramatti, R.; Park, H.K.; Park, I.H.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Petersen, B.; Piccolo, D.; Pierella, F.; Pieri, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Pothier, J.; Prokofev, D.O.; Prokofiev, D.; Quartieri, J.; Rahal-Callot, G.; Rahaman, M.A.; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Raven, G.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Rodin, J.; Roe, B.P.; Romero, L.; Rosca, A.; Rosier-Lees, S.; Roth, Stefan; Rosenbleck, C.; Roux, B.; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Sanders, M.P.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schmitz, D.; Schopper, H.; Schotanus, D.J.; Schwering, G.; Sciacca, C.; Seganti, A.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Siedenburg, T.; Son, D.; Smith, B.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stone, A.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Sushkov, S.; Suter, H.; Swain, J.D.; Szillasi, Z.; Sztaricskai, T.; Tang, X.W.; Tauscher, L.; Taylor, L.; Tellili, B.; Teyssier, D.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Uchida, Y.; Ulbricht, J.; Valente, E.; Vesztergombi, G.; Vetlitsky, I.; Vicinanza, D.; Viertel, G.; Villa, S.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobev, I.; Vorobov, A.A.; Vorvolakos, A.; Wadhwa, M.; Wallraff, W.; Wang, M.; Wang, X.L.; Wang, Z.M.; Weber, A.; Weber, M.; Wienemann, P.; Wilkens, H.; Wu, S.X.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, C.G.; Yang, H.J.; Yang, M.; Ye, J.B.; Yeh, S.C.; Zalite, A.; Zalite, Yu.; Zhang, Z.P.; Zhu, G.Y.; Zhu, R.Y.; Zichichi, A.; Zilizi, G.; Zimmermann, B.; Zoller, M.

    2001-01-01

    The process e^+e^- -> Z gamma gamma -> q q~ gamma gamma$ is studied in 0.5\\,fb-1$ of data collected with the L3 detector at centre-of-mass energies between 130.1 GeV and 201.7 GeV. Cross sections are measured and found to be consistent with the Standard Model expectations. The study of the least energetic photon constrains the quartic gauge boson couplings to -0.008 GeV-2 < a_0/\\Lambda^2 < 0.005 GeV-2 and -0.007 GeV-2 < a_c/\\Lambda^2 < 0.011 GeV-2, at 95% confidence level.

  18. New approach for calibration the efficiency of HPGe detectors

    International Nuclear Information System (INIS)

    Alnour, I.A.; Wagiran, H.; Suhaimi Hamzah; Siong, W.B.; Mohd Suhaimi Elias

    2013-01-01

    Full-text: This work evaluates the efficiency calibrating of HPGe detector coupled with Canberra GC3018 with Genie 2000 software and Ortec GEM25-76-XLB-C with Gamma Vision software; available at Neutron activation analysis laboratory in Malaysian Nuclear Agency (NM). The efficiency calibration curve was constructed from measurement of an IAEA, standard gamma point sources set composed by 214 Am, 57 Co, 133 Ba, 152 Eu, 137 Cs and 60 Co. The efficiency calibrations were performed for three different geometries: 5, 10 and 15 cm distances from the end cap detector. The polynomial parameters functions were simulated through a computer program, MATLAB in order to find an accurate fit to the experimental data points. The efficiency equation was established from the known fitted parameters which allow for the efficiency evaluation at particular energy of interest. The study shows that significant deviations in the efficiency, depending on the source-detector distance and photon energy. (author)

  19. Annihilation gamma ray background characterization and rejection for a positron camera

    International Nuclear Information System (INIS)

    Levin, C.S.; Tornai, M.P.; MacDonald, L.R.

    1996-01-01

    We have developed a miniature (1.2 cm 2 ) beta-ray camera prototype to assist a surgeon in locating and removing the margins of a resected tumor. When imaging positron emitting radiopharmaceuticals, annihilation gamma ray interactions in the detector can mimic those of the betas. The extent of the background contamination depends on the detector, geometry and tumor specificity of the radiopharmaceutical. We have characterized the effects that annihilation gamma rays have on positron imaging with the camera. We studied beta and gamma ray detection rates and imaging using small positron or electron sources directly exposed to the detector to simulate hot tumor remnants and a cylinder filled with 18 F to simulate annihilation background from the brain. For various ratios of phantom brain/tumor activity, a annihilation gamma rate of 1.8 cts/sec/gCi was measured in the CaF 2 (Eu) detector. We present two gamma-ray background rejection schemes that use a β-γ coincidence. Results show that the coincidence methods works with ∼99% gamma ray rejection efficiency

  20. Gamma-spectrometry of extended sources for analysing environmental samples

    International Nuclear Information System (INIS)

    Jarosievitz, B.

    1996-01-01

    Measurements of the environmental activity concentration by gamma spectrometers require the determination of the full-energy-peak efficiency as a function of photon energy over the detector range. This can be done by experiments or by calculation. For simple cases, experiments are straightforward, but if the decay scheme is complex, cascade effects modify detection efficiency. Also, actual detection efficiency depends on the detection geometry. All these effects are treated as corrections or modifications of the simple value cases which are especially relevant when applied to large volume of environmental samples. In this thesis calculations are made, using the GEANT MC program, for realistic experimental situations that have been performed, and these calculations are validated. The calculational and experimental results have been compared, and if it proves to be satisfactory, the results can be relied on even for cases when no direct experimental observation is possible. The general problems of gamma spectroscopy and correction problems are discussed. The two main tools, the experimental setup and the simulation program are described. A careful checking of the simulation results and the consequences are presented. (R.P.)

  1. System for gamma-gamma formation density logging while drilling

    International Nuclear Information System (INIS)

    Paske, W.C.

    1991-01-01

    The patent relates to a system for logging subterranean formations for the determination of formation density by using gamma radiation. Gamma ray source and detection means are disposed within a housing adapted for positioning within a borehole for the emission and detection of gamma rays propagating through earth formations and borehole drilling fluid. The gamma ray detection means comprises first and second gamma radiation sensors geometrically disposed within the housing, the same longitudinal distance from the gamma ray source and diametrically opposed in a common plane. A formation matrix density output signal is produced in proportion to the output signal from each of the gamma ray sensors and in conjunction with certain constants established by the geometrical configuration of the sensors relative to the gamma ray source and the borehole diameter. Formation density is determined without regard to the radial position of the logging probe within the borehole in a measuring while drilling mode. 6 figs

  2. IAEA research coordination meeting on X- and gamma-ray standards for detector efficiency calibration, Braunschweig, FRG, 31 May - 2 June 1989. Summary report

    International Nuclear Information System (INIS)

    Christmas, P.; Nichols, A.L.; Lemmel, H.D.

    1989-07-01

    The final official meeting of the IAEA Coordinated Research Programme on the Measurement and Evaluation of X- and Gamma-ray Standards for Detector Efficiency Calibration was held in Braunschweig from 31 May to 2 June 1989. Work undertaken by the participants was reviewed in detail, and actions were agreed to resolve specific issues and problems. Initial steps were also made to establish a format and procedure for the preparation by mid-1990 of an IAEA Technical Reports Series booklet; the measurements and recommended data will be listed, and an IAEA data file established for issue to all interested organisations. (author). 3 tabs

  3. Gamma motes for detection of radioactive materials in shipping containers

    International Nuclear Information System (INIS)

    Harold McHugh; William Quam; Stephan Weeks; Brendan Sever

    2007-01-01

    Shipping containers can be effectively monitored for radiological materials using gamma (and neutron) motes in distributed mesh networks. The mote platform is ideal for collecting data for integration into operational management systems required for efficiently and transparently monitoring international trade. Significant reductions in size and power requirements have been achieved for room-temperature cadmium zinc telluride (CZT) gamma detectors. Miniaturization of radio modules and microcontroller units are paving the way for low-power, deeply-embedded, wireless sensor distributed mesh networks

  4. Very high-energy gamma rays from gamma-ray bursts.

    Science.gov (United States)

    Chadwick, Paula M

    2007-05-15

    Very high-energy (VHE) gamma-ray astronomy has undergone a transformation in the last few years, with telescopes of unprecedented sensitivity having greatly expanded the source catalogue. Such progress makes the detection of a gamma-ray burst at the highest energies much more likely than previously. This paper describes the facilities currently operating and their chances for detecting gamma-ray bursts, and reviews predictions for VHE gamma-ray emission from gamma-ray bursts. Results to date are summarized.

  5. Efficient Bulk Operations on Dynamic R-Trees

    DEFF Research Database (Denmark)

    Arge, Lars Allan; Hinrichs, Klaus; Vahrenhold, Jan

    2002-01-01

    In recent years there has been an upsurge of interest in spatial databases. A major issue is how to manipulate efficiently massive amounts of spatial data stored on disk in multidimensional spatial indexes (data structures). Construction of spatial indexes (bulk loading ) has been studied...... intensively in the database community. The continuous arrival of massive amounts of new data makes it important to update existing indexes (bulk updating ) efficiently. In this paper we present a simple, yet efficient, technique for performing bulk update and query operations on multidimensional indexes. We...... present our technique in terms of the so-called R-tree and its variants, as they have emerged as practically efficient indexing methods for spatial data. Our method uses ideas from the buffer tree lazy buffering technique and fully utilizes the available internal memory and the page size of the operating...

  6. SPECULATIVE EFFICIENCY OF STOCK INDEX FUTURES MARKETS:AN ANALYSIS ON THE ASEAN MARKETS

    Directory of Open Access Journals (Sweden)

    Normas Awang

    2012-07-01

    Full Text Available The capital markets in emerging economies are undergoing rapid transformationdue to the advancement of technologicalinnovations and globalization of themarketplace. Thus, the risk managementmeasures are extremely importantthroughout the financial system. However,the scarcity of derivative instrumentssuch as futures and options in emergingmarkets, in addition to the failure togenerate liquidity, have made the emerging economies to be left behind in therecent development of the world capital markets. Whilethere are a great numberof earlier studies that analyse the efficiency of futures markets in differentcountries, there is a lack ofresearch that take intoaccount of the speculativeefficiency of futures markets which argues that futures prices are an unbiased forecast of the spot pricesas well as a crucial part offorecasting techniques. Thispaper aims to investigate the speculativeefficiency of stock index futures marketsin the ASEAN markets which comprises ofSingapore, Malaysia and Thailand byemploying an econometric time series dataanalysis ranging from January 2000 toDecember 2010.

  7. Brevion: the new small-scale industrial gamma irradiator

    International Nuclear Information System (INIS)

    McKinney, Dan; Perrins, Robert; Gibson, Wayne; Levesque, Daniel

    2002-01-01

    The economical processing of low-volume products has been a challenge to the gamma industry since inception, influencing customers to send their products to contractors or choose alternative technologies. With the introduction of the Brevion irradiator (patent pending), economical gamma processing of low annual volume product lines is now possible. This innovative design is specifically targeted at plants processing product volumes of up to 20,000 m 3 /yr. Brevion provides good cobalt efficiency and good dose uniformity, thus processing these volumes efficiently and economically. The Brevion facility has the distinct advantage of a low capital cost, compared to medium-sized automatic tote plants, while maintaining similar performance. Lead-time for the construction phase is also considerably shorter, resulting in significantly lower start-up costs. Companies with low-volume product lines can now achieve the control provided by in-house processing, and eliminate transportation time and costs associated with shipping products off-site

  8. Statistical analysis for discrimination of prompt gamma ray peak induced by high energy neutron: Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Do-Kun Yoon; Joo-Young Jung; Tae Suk Suh; Seong-Min Han

    2015-01-01

    The purpose of this research is a statistical analysis for discrimination of prompt gamma ray peak induced by the 14.1 MeV neutron particles from spectra using Monte Carlo simulation. For the simulation, the information of 18 detector materials was used to simulate spectra by the neutron capture reaction. The discrimination of nine prompt gamma ray peaks from the simulation of each detector material was performed. We presented the several comparison indexes of energy resolution performance depending on the detector material using the simulation and statistics for the prompt gamma activation analysis. (author)

  9. Analysis of the gamma spectra of the uranium, actinium, and thorium decay series

    International Nuclear Information System (INIS)

    Momeni, M.H.

    1981-09-01

    This report describes the identification of radionuclides in the uranium, actinium, and thorium series by analysis of gamma spectra in the energy range of 40 to 1400 keV. Energies and absolute efficiencies for each gamma line were measured by means of a high-resolution germanium detector and compared with those in the literature. A gamma spectroscopy method, which utilizes an on-line computer for deconvolution of spectra, search and identification of each line, and estimation of activity for each radionuclide, was used to analyze soil and uranium tailings, and ore

  10. The CD3 gamma leucine-based receptor-sorting motif is required for efficient ligand-mediated TCR down-regulation

    DEFF Research Database (Denmark)

    von Essen, Marina; Menné, Charlotte; Nielsen, Bodil L

    2002-01-01

    . The other pathway is dependent on protein kinase C (PKC)-mediated activation of the CD3 gamma di-leucine-based receptor-sorting motif. Previous studies have failed to demonstrate a connection between ligand- and PKC-induced TCR down-regulation. Thus, although an apparent paradox, the dogma has been...... that ligand- and PKC-induced TCR down-regulations are not interrelated. By analyses of a newly developed CD3 gamma-negative T cell variant, freshly isolated and PHA-activated PBMC, and a mouse T cell line, we challenged this dogma and demonstrate in this work that PKC activation and the CD3 gamma di...

  11. Upgrade of the JET gamma-ray cameras

    International Nuclear Information System (INIS)

    Soare, S.; Curuia, M.; Anghel, M.; Constantin, M.; David, E.; Craciunescu, T.; Falie, D.; Pantea, A.; Tiseanu, I.; Kiptily, V.; Prior, P.; Edlington, T.; Griph, S.; Krivchenkov, Y.; Loughlin, M.; Popovichev, S.; Riccardo, V; Syme, B.; Thompson, V.; Lengar, I.; Murari, A.; Bonheure, G.; Le Guern, F.

    2007-01-01

    JET GRC. The modelling was dedicated to the estimation of neutron and (plasma-emitted) gamma-ray attenuation, neutron-induced gamma-ray background and the neutron in-scattering impact on the neutron detectors due to the attenuator in the parking location. A numerical study of the gamma-ray detector (CsI(Tl)) was done by means of the IST Monte Carlo code. It provided preliminary results on the detector efficiency and response function. (authors)

  12. Fast amplification system for gamma spectroscopy

    International Nuclear Information System (INIS)

    Jesus, E.F.O.; Lopes, R.T.

    1992-01-01

    An amplification system for gamma spectroscopy with high counting rates was developed. The system was constructed with operational amplifiers, and tested and compared with ORTEC conventional system, using Iridium-192 as source of 9,25 x 10 1 0 Bq of activity and NaI (Tl) detector. The constructed system showed a better performance in relation to efficiency and resolution parameters, tested before. (C.G.C.)

  13. Exposure of luminous marine bacteria to low-dose gamma-radiation.

    Science.gov (United States)

    Kudryasheva, N S; Petrova, A S; Dementyev, D V; Bondar, A A

    2017-04-01

    The study addresses biological effects of low-dose gamma-radiation. Radioactive 137 Cs-containing particles were used as model sources of gamma-radiation. Luminous marine bacterium Photobacterium phosphoreum was used as a bioassay with the bioluminescent intensity as the physiological parameter tested. To investigate the sensitivity of the bacteria to the low-dose gamma-radiation exposure (≤250 mGy), the irradiation conditions were varied as follows: bioluminescence intensity was measured at 5, 10, and 20°С for 175, 100, and 47 h, respectively, at different dose rates (up to 4100 μGy/h). There was no noticeable effect of gamma-radiation at 5 and 10°С, while the 20°С exposure revealed authentic bioluminescence inhibition. The 20°С results of gamma-radiation exposure were compared to those for low-dose alpha- and beta-radiation exposures studied previously under comparable experimental conditions. In contrast to ionizing radiation of alpha and beta types, gamma-emission did not initiate bacterial bioluminescence activation (adaptive response). As with alpha- and beta-radiation, gamma-emission did not demonstrate monotonic dose-effect dependencies; the bioluminescence inhibition efficiency was found to be related to the exposure time, while no dose rate dependence was found. The sequence analysis of 16S ribosomal RNA gene did not reveal a mutagenic effect of low-dose gamma radiation. The exposure time that caused 50% bioluminescence inhibition was suggested as a test parameter for radiotoxicity evaluation under conditions of chronic low-dose gamma irradiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Spectrum of the isotropic diffuse gamma-ray emission derived from first-year Fermi Large Area Telescope data.

    Science.gov (United States)

    Abdo, A A; Ackermann, M; Ajello, M; Atwood, W B; Baldini, L; Ballet, J; Barbiellini, G; Bastieri, D; Baughman, B M; Bechtol, K; Bellazzini, R; Berenji, B; Blandford, R D; Bloom, E D; Bonamente, E; Borgland, A W; Bregeon, J; Brez, A; Brigida, M; Bruel, P; Burnett, T H; Buson, S; Caliandro, G A; Cameron, R A; Caraveo, P A; Casandjian, J M; Cavazzuti, E; Cecchi, C; Celik, O; Charles, E; Chekhtman, A; Cheung, C C; Chiang, J; Ciprini, S; Claus, R; Cohen-Tanugi, J; Cominsky, L R; Conrad, J; Cutini, S; Dermer, C D; de Angelis, A; de Palma, F; Digel, S W; Di Bernardo, G; do Couto e Silva, E; Drell, P S; Drlica-Wagner, A; Dubois, R; Dumora, D; Farnier, C; Favuzzi, C; Fegan, S J; Focke, W B; Fortin, P; Frailis, M; Fukazawa, Y; Funk, S; Fusco, P; Gaggero, D; Gargano, F; Gasparrini, D; Gehrels, N; Germani, S; Giebels, B; Giglietto, N; Giommi, P; Giordano, F; Glanzman, T; Godfrey, G; Grenier, I A; Grondin, M-H; Grove, J E; Guillemot, L; Guiriec, S; Gustafsson, M; Hanabata, Y; Harding, A K; Hayashida, M; Hughes, R E; Itoh, R; Jackson, M S; Jóhannesson, G; Johnson, A S; Johnson, R P; Johnson, T J; Johnson, W N; Kamae, T; Katagiri, H; Kataoka, J; Kawai, N; Kerr, M; Knödlseder, J; Kocian, M L; Kuehn, F; Kuss, M; Lande, J; Latronico, L; Lemoine-Goumard, M; Longo, F; Loparco, F; Lott, B; Lovellette, M N; Lubrano, P; Madejski, G M; Makeev, A; Mazziotta, M N; McConville, W; McEnery, J E; Meurer, C; Michelson, P F; Mitthumsiri, W; Mizuno, T; Moiseev, A A; Monte, C; Monzani, M E; Morselli, A; Moskalenko, I V; Murgia, S; Nolan, P L; Norris, J P; Nuss, E; Ohsugi, T; Omodei, N; Orlando, E; Ormes, J F; Paneque, D; Panetta, J H; Parent, D; Pelassa, V; Pepe, M; Pesce-Rollins, M; Piron, F; Porter, T A; Rainò, S; Rando, R; Razzano, M; Reimer, A; Reimer, O; Reposeur, T; Ritz, S; Rochester, L S; Rodriguez, A Y; Roth, M; Ryde, F; Sadrozinski, H F-W; Sanchez, D; Sander, A; Saz Parkinson, P M; Scargle, J D; Sellerholm, A; Sgrò, C; Shaw, M S; Siskind, E J; Smith, D A; Smith, P D; Spandre, G; Spinelli, P; Starck, J-L; Strickman, M S; Strong, A W; Suson, D J; Tajima, H; Takahashi, H; Takahashi, T; Tanaka, T; Thayer, J B; Thayer, J G; Thompson, D J; Tibaldo, L; Torres, D F; Tosti, G; Tramacere, A; Uchiyama, Y; Usher, T L; Vasileiou, V; Vilchez, N; Vitale, V; Waite, A P; Wang, P; Winer, B L; Wood, K S; Ylinen, T; Ziegler, M

    2010-03-12

    We report on the first Fermi Large Area Telescope (LAT) measurements of the so-called "extragalactic" diffuse gamma-ray emission (EGB). This component of the diffuse gamma-ray emission is generally considered to have an isotropic or nearly isotropic distribution on the sky with diverse contributions discussed in the literature. The derivation of the EGB is based on detailed modeling of the bright foreground diffuse Galactic gamma-ray emission, the detected LAT sources, and the solar gamma-ray emission. We find the spectrum of the EGB is consistent with a power law with a differential spectral index gamma = 2.41 +/- 0.05 and intensity I(>100 MeV) = (1.03 +/- 0.17) x 10(-5) cm(-2) s(-1) sr(-1), where the error is systematics dominated. Our EGB spectrum is featureless, less intense, and softer than that derived from EGRET data.

  15. SU-G-BRB-16: Vulnerabilities in the Gamma Metric

    International Nuclear Information System (INIS)

    Neal, B; Siebers, J

    2016-01-01

    Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: With a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm"2 field can have a 95% passing rate when an 8 cm"2=2.8×2.8 cm"2 highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.

  16. SU-G-BRB-16: Vulnerabilities in the Gamma Metric

    Energy Technology Data Exchange (ETDEWEB)

    Neal, B; Siebers, J [University of Virginia Health System, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: With a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm{sup 2} field can have a 95% passing rate when an 8 cm{sup 2}=2.8×2.8 cm{sup 2} highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.

  17. Radiation-induced reduction of diuron by gamma-ray irradiation

    International Nuclear Information System (INIS)

    Zhang Jibiao; Zheng Zheng; Zhao Tan; Zhao Yongfu; Wang Lianhong; Zhong Yun; Xu Yue

    2008-01-01

    Diuron degradation efficiencies and the proposed mechanism by gamma-ray irradiation were investigated. Several factors that might affect the degradation values were further examined. The UV absorbances at 200-400 nm and diuron concentration decreased with the increase of radiation dose. When diuron initial concentration was 18.5 mg L -1 and 1.0 kGy was selected as the radiation dose, diuron removal value and loss of total organic carbon were 100 and 34.1%, respectively. However, the concentration of Cl - ion increased with the increase of radiation dose. The process could be depicted by first order reaction kinetics and the reaction was mainly caused by the reaction of diuron with ·OH and e aq - . The degradation efficiency decreased with the increase of initial concentration at the same radiation dose. H 2 O 2 , HCO 3 - , NO 3 - , NO 2 - , CH 3 OH and humic acid as additives reduced the degradation efficiency. Furthermore, the increase of NO 3 - , NO 2 - , CH 3 OH and humic acid would result in the decrease of the degradation values. The pH value could affect the removal efficiency and the degradation process was enhanced in acid condition. The pH value became lower with increasing radiation dose after gamma-ray irradiation

  18. Cross-Section of Hadron Production in $\\gamma\\gamma$ Collisions at LEP

    CERN Document Server

    Acciarri, M; Aguilar-Benítez, M; Ahlen, S P; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alverson, G; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Baksay, L; Banerjee, S; Banerjee, Sw; Banicz, K; Barczyk, A; Barillère, R; Barone, L; Bartalini, P; Baschirotto, A; Basile, M; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Bhattacharya, S; Biasini, M; Biland, A; Bilei, G M; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böck, R K; Böhm, A; Boldizsar, L; Borgia, B; Bourilkov, D; Bourquin, Maurice; Braccini, S; Branson, J G; Brigljevic, V; Brock, I C; Buffini, A; Buijs, A; Burger, J D; Burger, W J; Busenitz, J K; Button, A M; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A M; Casaus, J; Castellini, G; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada-Canales, M; Cesaroni, F; Chamizo-Llatas, M; Chang, Y H; Chaturvedi, U K; Chekanov, S V; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chéreau, X J; Chiefari, G; Chien, C Y; Cifarelli, Luisa; Cindolo, F; Civinini, C; Clare, I; Clare, R; Cohn, H O; Coignet, G; Colijn, A P; Colino, N; Commichau, V; Costantini, S; Cotorobai, F; de la Cruz, B; Csilling, Akos; Dai, T S; D'Alessandro, R; De Asmundis, R; Degré, A; Deiters, K; Della Volpe, D; Denes, P; De Notaristefani, F; DiBitonto, Daryl; Diemoz, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, Michael; Dominguez, A; Doria, A; Dova, M T; Duchesneau, D; Duinker, P; Durán, I; Dutta, S; Easo, S; Efremenko, Yu V; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Ernenwein, J P; Extermann, Pierre; Fabre, M; Faccini, R; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, Marta; Fenyi, B; Ferguson, T; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, Frank; Fisher, P H; Fisk, I; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gau, S S; Gentile, S; Gheordanescu, N; Giagu, S; Goldfarb, S; Goldstein, J; Gong, Z F; Gougas, Andreas; Gratta, Giorgio; Grünewald, M W; Gupta, V K; Gurtu, A; Gutay, L J; Hartmann, B; Hasan, A; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Van Hoek, W C; Hofer, H; Hong, S J; Hoorani, H; Hou, S R; Hu, G; Innocente, Vincenzo; Jenkes, K; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kasser, A; Khan, R A; Kamrad, D; Kamyshkov, Yu A; Kapustinsky, J S; Karyotakis, Yu; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, D H; Kim, J K; Kim, S C; Kim, Y G; Kinnison, W W; Kirkby, A; Kirkby, D; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Kopp, A; Korolko, I; Koutsenko, V F; Krämer, R W; Krenz, W; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lapoint, C; Lassila-Perini, K M; Laurikainen, P; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Le Goff, J M; Leiste, R; Leonardi, E; Levchenko, P M; Li Chuan; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lu, W; Lü, Y S; Lübelsmeyer, K; Luci, C; Luckey, D; Luminari, L; Lustermann, W; Ma Wen Gan; Maity, M; Majumder, G; Malgeri, L; Malinin, A; Maña, C; Mangeol, D J J; Mangla, S; Marchesini, P A; Marin, A; Martin, J P; Marzano, F; Massaro, G G G; McNally, D; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Von der Mey, M; Mi, Y; Mihul, A; Van Mil, A J W; Mirabelli, G; Mnich, J; Molnár, P; Monteleoni, B; Moore, R; Morganti, S; Moulik, T; Mount, R; Müller, S; Muheim, F; Muijs, A J M; Nahn, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Niessen, T; Nippe, A; Nisati, A; Nowak, H; Oh, Yu D; Opitz, H; Organtini, G; Ostonen, R; Palomares, C; Pandoulas, D; Paoletti, S; Paolucci, P; Park, H K; Park, I H; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Peach, D; Pei, Y J; Pensotti, S; Perret-Gallix, D; Petersen, B; Petrak, S; Pevsner, A; Piccolo, D; Pieri, M; Pinto, J C; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Produit, N; Prokofev, D; Prokofiev, D O; Rahal-Callot, G; Raja, N; Rancoita, P G; Rattaggi, M; Raven, G; Razis, P A; Read, K; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riles, K; Robohm, A; Rodin, J; Roe, B P; Romero, L; Rosier-Lees, S; Rosselet, P; Van Rossum, W; Roth, S; Rubio, Juan Antonio; Ruschmeier, D; Rykaczewski, H; Salicio, J; Sánchez, E; Sanders, M P; Sarakinos, M E; Sarkar, S; Sassowsky, M; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schmitz, P; Scholz, N; Schopper, Herwig Franz; Schotanus, D J; Schwenke, J; Schwering, G; Sciacca, C; Sciarrino, D; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shukla, J; Shumilov, E; Shvorob, A V; Siedenburg, T; Son, D; Sopczak, André; Smith, B; Spillantini, P; Steuer, M; Stickland, D P; Stone, A; Stone, H; Stoyanov, B; Strässner, A; Strauch, K; Sudhakar, K; Sultanov, G G; Sun, L Z; Susinno, G F; Suter, H; Swain, J D; Tang, X W; Tauscher, Ludwig; Taylor, L; Ting, Samuel C C; Ting, S M; Tonutti, M; Tonwar, S C; Tóth, J; Tully, C; Tuchscherer, H; Tung, K L; Uchida, Y; Ulbricht, J; Uwer, U; Valente, E; Van de Walle, R T; Vesztergombi, G; Vetlitskii, I; Viertel, Gert M; Vivargent, M; Völkert, R; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, J C; Wang, X L; Wang, Z M; Weber, A; Wittgenstein, F; Wu, S X; Wynhoff, S; Xu, J; Xu, Z Z; Yang, B Z; Yang, C G; Yao, X Y; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zemp, P; Zeng, Y; Zhang, Z; Zhang, Z P; Zhou, B; Zhu, G Y; Zhu, R Y; Zichichi, Antonino; Ziegler, F

    1997-01-01

    The reaction $\\mathrm{e}^{+} \\mathrm{e}^{-} \\rightarrow \\mathrm{e}^{+} \\mathrm{e}^{-} \\gamma ^{*} \\gamma ^{*} \\rightarrow \\mathrm{e}^{+} \\mathrm{e}^{-} $ {\\sl hadrons} is analysed using data collected by the L3 detector during the LEP runs at $\\sqrt {s}$ = 130-140 GeV and $\\sqrt {s}$ = 161 GeV. The cross sections $\\sigma(\\mathrm{e}^{+} \\mathrm{e}^{-} \\rightarrow \\mathrm{e}^{+} \\mathrm{e}^{-} $ {\\sl hadrons}) and $\\sigma (\\gamma\\gamma \\rightarrow $ {\\sl hadrons}) are measured in the interval 5 $\\leq W_{\\gamma\\gamma} \\leq$ 75 GeV. The energy dependence of the $\\sigma (\\gamma\\gamma \\rightarrow $ {\\sl hadrons}) cross section is consistent with the universal Regge behaviour of total hadronic cross sections. %\\end{abstract}

  19. 134Cs emission probabilities determination by gamma spectrometry

    Science.gov (United States)

    de Almeida, M. C. M.; Poledna, R.; Delgado, J. U.; Silva, R. L.; Araujo, M. T. F.; da Silva, C. J.

    2018-03-01

    The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed primary and secondary standardization of different radionuclides reaching satisfactory uncertainties. A solution of 134Cs radionuclide was purchased from commercial supplier to emission probabilities determination of some of its energies. 134Cs is a beta gamma emitter with 754 days of half-life. This radionuclide is used as standard in environmental, water and food control. It is also important to germanium detector calibration. The gamma emission probabilities (Pγ) were determined mainly for some energies of the 134Cs by efficiency curve method and the Pγ absolute uncertainties obtained were below 1% (k=1).

  20. Albumin grafting on polymer surfaces by gamma-irradiation

    International Nuclear Information System (INIS)

    Kamath, K.R.; Park, K.; DeMeo, D.

    1993-01-01

    Polymeric biomaterial surfaces were modified by albumin grafting to improve their blood compatibility. Albumin molecules were functionalized by introduction of double bonds. The functionalized albumin was covalently attached to polypropylene fibers, polycarbonate, and poly(vinyl chloride) by gamma-irradiation. ESCA and ATR/FTIR analysis of the control and grafted surfaces was conducted. Albumin grafting efficiency was found to be dependent on the gamma-irradiation time and the concentration of albumin as indicated by platelet adhesion studies. The grafted albumin molecules were not displaced when exposed to blood for prolonged time period. Finally, PLEXUS oxygenators grafted with albumin using this approach showed a significant reduction in platelet adhesion when compared to control

  1. Validation of gamma spectrometer in spectroscopy laboratory of education and training center BATAN

    International Nuclear Information System (INIS)

    Sugino; Tulisna; Anda Sanusi; Sugito

    2010-01-01

    Gamma spectrometer used to determine the type and activity of gamma emitting radionuclides, such as the measurement of environmental radioactivity and neutron activation analysis (NAA). In order to obtain precise and accurate qualitative and quantitative analysis, the gamma spectrometer should be validated. Validation of the gamma spectrometer was conducted on the confirmation of identity, differential linearity, performance, efficiency calibration, precision test, and accuracy test. Confirmation of identity conducted by energy calibration testing conducted and showed the largest energy deviation of 0.3 keV. Differential linearity testing showed the highest count difference of 6.9 %. Test Results for 1 year showed the lowest resolution of 1.82 keV, in accordance with the initial resolution of 1.8 keV. Value of lowest P/C is 59.8, according to the first P/C of 60. The lowest relative efficiency of 28.6 %, according to the initial efficiency of 30 %. Calibration curve shows that for more than 200 keV energy, the relationship of Ln Energy vs Ln Efficiency is a straight line with equation Ln(ε) = 7.211-0.8173 Ln(E), while for less than 100 keV energy the the equation Ln(ε) = -13.34+6.712Ln(E)+0.06894 Ln(E)"2, in accordance with the theory and references. Precision test conducted by chi square value of 10.6, according to probability of 5 % to 95 %. Testing the accuracy is shown from the results of comparative tests of measuring I-131 activity in 2009 with good results, the difference in the results of 2.35 % with the uncertainty of 6 %. (author)

  2. Physiological response of lovage (levisticum officinale, koch) plant to gamma radiation and organic fertilizers

    International Nuclear Information System (INIS)

    Taha, A.T.A.

    2009-01-01

    The main objective of this work is to study physiological response of lovage plant to gamma radiation and organic fertilizers.Two field experiments were conduct under conditions of newly reclaimed soil (sandy loam soil) during two successive seasons (2003/2004 and 2004/2005) in experimental farm , NRC,AEA Inshas. lovage fruits were irradiated before sowing with gamma rays at 0,20,40,60 and 80 Gy. Before planting farm yard manure (FYM) at rates of 0,20,30 and 40 m 3 /fed. Was applied to soil in combination with gamma doses in the first experiment, in the second one, chicken manure at 0,10,15 and 20 m 3 /fed. was added to soil before planting in combination with the same used gamma doses in first experiment. Growth of lovage plants was considerably stimulated by irradiating fruits before sowing with low gamma doses, in particularly at 60 Gy, which greatly increased plant height, number of branches/plant, stem thickness and dry matter yield of shoots. Similar trend was also observed with leaf chlorophyll content which increased due to low gamma doses . Low gamma doses markedly encouraged nutrients uptake by lovage plants which increased levels and total contents of N, P, K, Fe,Zn and Mn in plant shoots. Fruits yield, volatile oil % and oil yield and fruits index value were increased by low gamma doses particularly at 60 Gy.

  3. Browse Title Index

    African Journals Online (AJOL)

    Items 851 - 900 of 1255 ... Vol 16, No 4 (2010), Origin and generation mechanisms of ... Vol 13, No 4 (2007), Osmotic fragility index of HBAA red blood cells in the presence of ... (2004), Photovoltaic cells, efficiency and optimization, Abstract PDF.

  4. Efficient and Robust Detection of GFSK Signals under Dispersive Channel, Modulation Index, and Carrier Frequency Offset Conditions

    Directory of Open Access Journals (Sweden)

    Stephan Weiss

    2005-09-01

    Full Text Available Gaussian frequency shift keying is the modulation scheme specified for Bluetooth. Signal adversities typical in Bluetooth networks include AWGN, multipath propagation, carrier frequency, and modulation index offsets. In our effort to realise a robust but efficient Bluetooth receiver, we adopt a high-performance matched-filter-based detector, which is near optimal in AWGN, but requires a prohibitively costly filter bank for processing of K bits worth of the received signal. However, through filtering over a single bit period and performing phase propagation of intermediate results over successive single-bit stages, we eliminate redundancy involved in providing the matched filter outputs and reduce its complexity by up to 90% (for K=9. The constant modulus signal characteristic and the potential for carrier frequency offsets make the constant modulus algorithm (CMA suitable for channel equalisation, and we demonstrate its effectiveness in this paper. We also introduce a stochastic gradient-based algorithm for carrier frequency offset correction, and show that the relative rotation between successive intermediate filter outputs enables us to detect and correct offsets in modulation index.

  5. Design of a Gamma Reaction History Diagnostic for the National Ignition Facility

    International Nuclear Information System (INIS)

    Malone, R.M.; Cox, B.C.; Frogget, B.C.; Kaufman, M.I.; Tunnell, T.W.; Herrmann, H.W.; Evans, S.C.; Mack, J.M; Young, C.S.; Stoeffl, W.

    2009-01-01

    Gas Cherenkov detectors have been used to convert fusion gammas into photons to achieve gamma reaction history (GRH) measurements. These gas detectors include a converter, pressurized gas volume, relay optics, and a photon detector. A novel design for the National Ignition Facility (NIF) using 90 o Off-Axis Parabolic mirrors efficiently collects signal from fusion gammas with 8-ps time dispersion.1 Fusion gammas are converted to Compton electrons, which generate broadband Cherenkov light (our response is from 250 to 700 nm) in a pressurized gas cell. This light is relayed into a high-speed detector using three parabolic mirrors. The detector optics collect light from a 125-mm-diameter by 600-mm-long interchangeable gas (CO2 or SF6) volume. Because light is collected from source locations throughout the gas volume, the detector is positioned at the stop position rather than at an image position. The stop diameter and its position are independent of the light-generation locations along the gas cell. This design incorporates a fixed time delay that allows the detector to recover from prompt radiation. Optical ray tracings demonstrate how light can be collected from different angled trajectories of the Compton electrons as they traverse the gas volume. A Monte Carlo model of the conversion process from gammas to Cherenkov photons is used to generate photon trajectories. The collection efficiencies for different gamma energies are evaluated. At NIF, a cluster of four channels will allow for increased dynamic range, as well as different gamma energy thresholds. This GRH design is compared to a gas Cherenkov detector that utilizes a Cassegrain reflector now used at the OMEGA laser facility. 1. R. M. Malone, H. W. Herrmann, W. Stoeffl, J. M. Mack, C. S. Young, 'Gamma bang time/reaction history diagnostics for the National Ignition Facility using 90 o off-axis parabolic mirrors', Rev. Sci. Instrum. 79, 10E532 (2008)

  6. Enhanced release of bone morphogenetic proteins from demineralized bone matrix by gamma irradiation

    International Nuclear Information System (INIS)

    Sung, Nak-Yun; Choi, Jong-il

    2015-01-01

    Gamma irradiation is a useful method for sterilizing demineralized bone matrix (DBM), but its effect on the osteoinductivity of DBM is still controversial. In this study, the osteoinductive activity of gamma-irradiated DBM was examined using a mouse myoblastic cell line (C2C12). DBM was extracted from adult bovine bone and was irradiated at a dose of 25 kGy using a 60 cobalt gamma-irradiator. Cell proliferation with DBM was not affected by gamma-irradiation, but alkaline phosphatase and osteocalcin productions were significantly increased in C2C12 cell groups treated with gamma-irradiated DBM. It was reasoned that bone morphogenetic proteins were more efficiently released from gamma-irradiated DBM than from the non-irradiated control. This result suggests the effectiveness of radiation sterilization of bone implants - Highlights: • Demineralized bone matrix (DBM) was gamma-irradiated for sterilization. • Irradiated DBM had higher alkaline phosphatase and osteocalcin production. • It was reasoned the more released bone morphogenetic proteins by irradiation. • This result supports the application of radiation sterilization for bone implants

  7. Indexing for summary queries

    DEFF Research Database (Denmark)

    Yi, Ke; Wang, Lu; Wei, Zhewei

    2014-01-01

    ), of a particular attribute of these records. Aggregation queries are especially useful in business intelligence and data analysis applications where users are interested not in the actual records, but some statistics of them. They can also be executed much more efficiently than reporting queries, by embedding...... returned by reporting queries. In this article, we design indexing techniques that allow for extracting a statistical summary of all the records in the query. The summaries we support include frequent items, quantiles, and various sketches, all of which are of central importance in massive data analysis....... Our indexes require linear space and extract a summary with the optimal or near-optimal query cost. We illustrate the efficiency and usefulness of our designs through extensive experiments and a system demonstration....

  8. X-ray and gamma ray waveguide, cavity and method

    International Nuclear Information System (INIS)

    Vali, V.; Krogstad, R.S.; Willard, H.R.

    1978-01-01

    An x-ray and gamma ray waveguide, cavity, and method for directing electromagnetic radiation of the x-ray, gamma ray, and extreme ultraviolet wavelengths are described. A hollow fiber is used as the waveguide and is manufactured from a material having an index of refraction less than unity for these wavelengths. The internal diameter of the hollow fiber waveguide and the radius of curvature for the waveguide are selectively predetermined in light of the wavelength of the transmitted radiation to minimize losses. The electromagnetic radiation is obtained from any suitable source ad upon introduction into the waveguide is transmitted along a curvilinear path. The waveguide may be formed as a closed loop to create a cavity or may be used to direct the electromagnetic radiation to a utilization site

  9. Evaluation of Different Score Index for Predicting Prognosis in Gamma Knife Radiosurgical Treatment for Brain Metastasis

    International Nuclear Information System (INIS)

    Franzin, Alberto; Snider, Silvia; Picozzi, Piero; Bolognesi, Angelo; Serra, Carlo; Vimercati, Alberto; Passarin, Olga; Mortini, Pietro

    2009-01-01

    Purpose: To assess the utility of the Radiation Therapy Oncology Group Recursive Partitioning Analysis (RPA) and Score Index for Radiosurgery (SIR) stratification systems in predicting survival in patients with brain metastasis treated with Gamma Knife radiosurgery (GKRS). Methods and Materials: A total of 185 patients were included in the study. Patients were stratified according to RPA and SIR classes. The RPA and SIR classes, age, Karnofsky Performance Status (KPS), and systemic disease were correlated with survival. Results: Five patients were lost to follow-up. Median survival in patients in RPA Class 1 (30 patients) was 17 months; in Class 2 (140 patients), 10 months; and in Class 3 (10 patients), 3 months. Median survival in patients in SIR Class 1 (30 patients) was 3 months; in Class 2 (135 patients), 8 months; and in Class 3 (15 patients), 20 months. In univariate testing, age younger than 65 years (p = 0.0004), KPS higher than 70 (p = 0.0001), RPA class (p = 0.0078), SIR class (p = 0.0002), and control of the primary tumor (p = 0.02) were significantly associated with improved outcome. In multivariate analysis, KPS (p < 0.0001), SIR class (p = 0.0008), and RPA class (p = 0.03) had statistical value. Conclusions: This study supports the use of GKRS as a single-treatment modality in this selected group of patients. Stratification systems are useful in the estimation of patient eligibility for GKRS. A second-line treatment was necessary in 30% of patients to achieve distal or local brain control. This strategy is useful to control brain metastasis in long-surviving patients.

  10. Gamma irradiation effects in low density polyethylene

    International Nuclear Information System (INIS)

    Ono, Lilian S.; Scagliusi, Sandra R.; Cardoso, Elisabeth E.L.; Lugao, Ademar B.

    2011-01-01

    Low density polyethylene (LDPE) is obtained from ethylene gas polymerization, being one of the most commercialized polymers due to its versatility and low cost. It's a semi-crystalline polymer, usually inactive at room temperature, capable to attain temperatures within a 80 deg C - 100 deg C range, without changing its physical-chemical properties. LDPE has more resistance when compared to its equivalent High Density Polyethylene (HDPE). LDPE most common applications consist in manufacturing of laboratory materials, general containers, pipes, plastic bags, etc. Gamma radiation is used on polymers in order to modify mechanical and physical-chemical features according to utility purposes. This work aims to the study of gamma (γ) radiation interaction with low density polyethylene to evaluate changes in its physical-chemical properties. Polymer samples were exposed to 5, 10, 15, 20 and 30kGy doses, at room temperature. Samples characterization employed Thermal Analysis, Melt Flow Index, Infrared Spectroscopy and Swelling tests. (author)

  11. Study on the physiological activities of gamma-irradiated seafood cooking drips

    International Nuclear Information System (INIS)

    Jo, Eu Ri; Kim, Yeon Joo; Choi, Jong Il; Sung, Nak Yun; Jung, Pil Moon; Kim, Jae Hun; Song, Beom Seok; Yoon, Yo Han; Lee, Ju Woon; Lee, Ju Yeoun

    2010-01-01

    Cooking drips which were obtained as by-product after seafood processing in the food industries, still contain lost of proteins, carbohydrates, and other functional materials. This study was conducted to investigate the effect of gamma irradiation on the biological activities of seafood cooking drips. When the cooking drips of Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus were irradiated, the antioxidant activities, whitening effect, and angiotensin I converting enzyme inhibition activity of the ethanol extract from seafood cooking drips were all increased by gamma irradiation. This was because of the increased extraction efficiency of available compounds by irradiation. These results suggested that the seafood cooking drips, wasted as by-products, can be used as functional compounds with gamma irradiation treatment

  12. Study on the physiological activities of gamma-irradiated seafood cooking drips

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Eu Ri; Kim, Yeon Joo; Choi, Jong Il; Sung, Nak Yun; Jung, Pil Moon; Kim, Jae Hun; Song, Beom Seok; Yoon, Yo Han; Lee, Ju Woon [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Lee, Ju Yeoun [Chonbuk National University, Jeonju (Korea, Republic of)

    2010-03-15

    Cooking drips which were obtained as by-product after seafood processing in the food industries, still contain lost of proteins, carbohydrates, and other functional materials. This study was conducted to investigate the effect of gamma irradiation on the biological activities of seafood cooking drips. When the cooking drips of Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus were irradiated, the antioxidant activities, whitening effect, and angiotensin I converting enzyme inhibition activity of the ethanol extract from seafood cooking drips were all increased by gamma irradiation. This was because of the increased extraction efficiency of available compounds by irradiation. These results suggested that the seafood cooking drips, wasted as by-products, can be used as functional compounds with gamma irradiation treatment.

  13. Quantitative portable gamma spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Enghauser, M.W.; Ebara, S.B.

    1997-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma spectroscopy system is impractical. The portable gamma spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma rays and cannot be used for pure beta emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma rays. The following presents the analysis technique and presents verification results demonstrating the accuracy of the method

  14. Delta-gamma-theta Hedging of Crude Oil Asian Options

    Directory of Open Access Journals (Sweden)

    Juraj Hruška

    2015-01-01

    Full Text Available Since Black-Scholes formula was derived, many methods have been suggested for vanilla as well as exotic options pricing. More of investing and hedging strategies have been developed based on these pricing models. Goal of this paper is to derive delta-gamma-theta hedging strategy for Asian options and compere its efficiency with gamma-delta-theta hedging combined with predictive model. Fixed strike Asian options are type of exotic options, whose special feature is that payoff is calculated from the difference of average market price and strike price for call options and vice versa for the put options. Methods of stochastic analysis are used to determine deltas, gammas and thetas of Asian options. Asian options are cheaper than vanilla options and therefore they are more suitable for precise portfolio creation. On the other hand their deltas are also smaller as well as profits. That means that they are also less risky and more suitable for hedging. Results, conducted on chosen commodity, confirm better feasibility of Asian options compering with vanilla options in sense of gamma hedging.

  15. Handheld real-time volumetric 3-D gamma-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Haefner, Andrew, E-mail: ahaefner@lbl.gov [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Barnowski, Ross [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Luke, Paul; Amman, Mark [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, Kai [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2017-06-11

    This paper presents the concept of real-time fusion of gamma-ray imaging and visual scene data for a hand-held mobile Compton imaging system in 3-D. The ability to obtain and integrate both gamma-ray and scene data from a mobile platform enables improved capabilities in the localization and mapping of radioactive materials. This not only enhances the ability to localize these materials, but it also provides important contextual information of the scene which once acquired can be reviewed and further analyzed subsequently. To demonstrate these concepts, the high-efficiency multimode imager (HEMI) is used in a hand-portable implementation in combination with a Microsoft Kinect sensor. This sensor, in conjunction with open-source software, provides the ability to create a 3-D model of the scene and to track the position and orientation of HEMI in real-time. By combining the gamma-ray data and visual data, accurate 3-D maps of gamma-ray sources are produced in real-time. This approach is extended to map the location of radioactive materials within objects with unknown geometry.

  16. Index Compression and Efficient Query Processing in Large Web Search Engines

    Science.gov (United States)

    Ding, Shuai

    2013-01-01

    The inverted index is the main data structure used by all the major search engines. Search engines build an inverted index on their collection to speed up query processing. As the size of the web grows, the length of the inverted list structures, which can easily grow to hundreds of MBs or even GBs for common terms (roughly linear in the size of…

  17. SU-F-T-368: Improved HPGe Detector Precise Efficiency Calibration with Monte Carlo Simulations and Radioactive Sources

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Y. John [Vanderbilt University, Vanderbilt-Ingram Cancer Center, Nashville, TN 37232 (United States)

    2016-06-15

    Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excited states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.

  18. Imaging capabilities of germanium gamma cameras

    International Nuclear Information System (INIS)

    Steidley, J.W.

    1977-01-01

    Quantitative methods of analysis based on the use of a computer simulation were developed and used to investigate the imaging capabilities of germanium gamma cameras. The main advantage of the computer simulation is that the inherent unknowns of clinical imaging procedures are removed from the investigation. The effects of patient scattered radiation were incorporated using a mathematical LSF model which was empirically developed and experimentally verified. Image modifying effects of patient motion, spatial distortions, and count rate capabilities were also included in the model. Spatial domain and frequency domain modeling techniques were developed and used in the simulation as required. The imaging capabilities of gamma cameras were assessed using low contrast lesion source distributions. The results showed that an improvement in energy resolution from 10% to 2% offers significant clinical advantages in terms of improved contrast, increased detectability, and reduced patient dose. The improvements are of greatest significance for small lesions at low contrast. The results of the computer simulation were also used to compare a design of a hypothetical germanium gamma camera with a state-of-the-art scintillation camera. The computer model performed a parametric analysis of the interrelated effects of inherent and technological limitations of gamma camera imaging. In particular, the trade-off between collimator resolution and collimator efficiency for detection of a given low contrast lesion was directly addressed. This trade-off is an inherent limitation of both gamma cameras. The image degrading effects of patient motion, camera spatial distortions, and low count rate were shown to modify the improvements due to better energy resolution. Thus, based on this research, the continued development of germanium cameras to the point of clinical demonstration is recommended

  19. Design and environmental applications of an ultra-low-background, high-efficiency intrinsic Ge gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1981-04-01

    A coincidence shielded intrinsic Ge gamma-ray spectrometer incorporating a 25% efficient, high resolution coaxial diode inside a 30 cm diameter NaI(Tl) shield is described. System design eliminates the major cause of background and minimizes cosmic-ray created background events through the use of electronic means. The system provides a peak-to-Compton ratio of greater than 1000 to 1 for 137 Cs and high sensitivity for both low and high level radionuclide measurements. At 3 MeV the background is 0.000058 counts per minute per keV. At 1 MeV it is 0.00048 counts per minute per keV, and at 0.5 MeV it is 0.0045 counts per minute per keV. Traces of primordial radionuclides create background events such as at 2.614 MeV (0.016 counts per minute total peak area), at 2.448 MeV (0.0058 counts per minute per total peak area), and at 2.204 MeV (0.023 counts per minute per total peak area). The system is discussed with respect to its background design, methods to improve its design, and its application to measurements of neutron activated and environmental materials problems

  20. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  1. Plug pattern optimization for gamma knife radiosurgery treatment planning

    International Nuclear Information System (INIS)

    Zhang Pengpeng; Wu, Jackie; Dean, David; Xing Lei; Xue Jinyue; Maciunas, Robert; Sibata, Claudio

    2003-01-01

    Purpose: To develop a novel dose optimization algorithm for improving the sparing of critical structures during gamma knife radiosurgery by shaping the plug pattern of each individual shot. Method and Materials: We first use a geometric information (medial axis) aided guided evolutionary simulated annealing (GESA) optimization algorithm to determine the number of shots and isocenter location, size, and weight of each shot. Then we create a plug quality score system that checks the dose contribution to the volume of interest by each plug in the treatment plan. A positive score implies that the corresponding source could be open to improve tumor coverage, whereas a negative score means the source could be blocked for the purpose of sparing normal and critical structures. The plug pattern is then optimized via the GESA algorithm that is integrated with this score system. Weight and position of each shot are also tuned in this procedure. Results: An acoustic tumor case is used to evaluate our algorithm. Compared to the treatment plan generated without plug patterns, adding an optimized plug pattern into the treatment planning process boosts tumor coverage index from 95.1% to 97.2%, reduces RTOG conformity index from 1.279 to 1.167, lowers Paddick's index from 1.34 to 1.20, and trims the critical structure receiving more than 30% maximum dose from 16 mm 3 to 6 mm 3 . Conclusions: Automated GESA-based plug pattern optimization of gamma knife radiosurgery frees the treatment planning team from the manual forward planning procedure and provides an optimal treatment plan

  2. Efficiency-optimized low-cost TDPAC spectrometer using a versatile routing/coincidence unit

    Energy Technology Data Exchange (ETDEWEB)

    Renteria, M., E-mail: renteria@fisica.unlp.edu.ar; Bibiloni, A. G.; Darriba, G. N.; Errico, L. A.; Munoz, E. L.; Richard, D.; Runco, J. [Universidad Nacional de La Plata, Departamento de Fisica, Facultad de Ciencias Exactas (Argentina)

    2008-01-15

    A highly efficient, reliable, and low-cost {gamma}-{gamma} TDPAC spectrometer, PACAr, optimized for {sup 181}Hf-implanted low-activity samples, is presented. A versatile EPROM-based routing/coincidence unit was developed and implemented to be use with the memory-card-based multichannel analyzer hosted in a personal computer. The excellent energy resolution and very good overall resolution and efficiency of PACAr are analyzed and compare with advanced and already tested fast-fast and slow-fast PAC spectrometers.

  3. Development of a gamma camera based on a multiwire proportional counter

    International Nuclear Information System (INIS)

    Anisimov, Yu.S.; Zanevskij, Yu.V.; Ivanov, A.B.

    1981-01-01

    The developed high-pressure gamma-chamber based on a gas multiwire detector is discussed. The main characteristics of the detector for a gamma-ray energy of up to 100 keV are given. The chamber operation is possible at a pressure of up to 10 atm. The detector is filled with a Xe-CH 4 (90-10) mixture. The detector efficiency is about 50%, the space resolution is better than 2 mm at a working region of 280x280 mm [ru

  4. A gamma-ray tracking detector for molecular imaging

    International Nuclear Information System (INIS)

    Hall, C.J.; Lewis, R.A.; Helsby, W.I.; Nolan, P.; Boston, A.

    2003-01-01

    A design for a gamma-ray detector for molecular imaging is presented. The system is based on solid-state strip detector technology. The advantages of position sensitivity coupled with fine spectral resolution are exploited to produce a tracking detector for use with a variety of isotopes in nuclear medicine. Current design concepts employ both silicon and germanium layers to provide an energy range from 60 keV to >1 MeV. This allows a reference X-ray image to be collected simultaneously with the gamma-ray image providing accurate anatomical registration. The tracking ability of the gamma-ray detector allows ambiguities in the data set to be resolved which would otherwise cause events to be rejected in standard non-tracking system. Efficiency improvements that high solid angle coverage and the use of a higher proportion of events make time resolved imaging and multi-isotope work possible. A modular detector system, designed for viewing small animals has been accepted for funding

  5. Portable scintillation gamma-spectrometer for field measurement of radioactivity in extensive objects; Portativnyj stsintillyatsionnyj gamma-spektrometr dlya izmereniya radioaktivnosti ob''emnykh sred v polevykh usloviyakh

    Energy Technology Data Exchange (ETDEWEB)

    Besshejko, O. A. [Taras Shevchenko National University of Kyiv, Kyiv (Ukraine); Vishnevskij, I. N.; Denisenko, R. V.; Malyuk, I. A.; Petrosyan, Eh. E. [Institute for Nuclear Research, Kyiv (Ukraine); Karpenko, S. A.; Prijmak, V. N. [Ukrainian Association for Valves Industry, Dnepropetrovsk (Ukraine)

    2011-07-01

    The portable scintillated gamma-spectrometer for field measurement of radioactivity in the volume objects was designed. The crystal CdWO{sub 4} that has weak dependence of light yield from temperature in combination with PMT was applied as the gamma-rays detector. The design of the device provides the possibility for measuring radioactivity of the extensive objects in 4{pi}-geometry without background measurements. In this case the value of the efficiency needed for specific activity calculation in close approximation depends only from crystal geometry and density of measuring object and may be set as the device parameter without efficiency calibration procedure during the operation. The spectrometer does not have an auxiliary radio-active source and connecting cables in the composition. The smartphone operated under Windows Mobile is used as the control module. Bluetooth connection provides data exchange between smartphone and measurement head.

  6. Gamma radiation effects in Ascaris sp. eggs in the treated and untreated sewage

    International Nuclear Information System (INIS)

    Bastos, Gloria S.M.; Chernicharo, Carlos A.L.; Zerbini, Adriana M.

    2005-01-01

    This work evaluated the efficiency of domestic sewage disinfection. The sewage was treated in UASB reactor (upflow anaerobic sludge blanket), and the influent and affluent disinfection was promoted by gamma irradiation. To test the efficiency of disinfection, Ascaris eggs viability was analyzed undo microscopic observation in samples before and after the irradiation. The Ascaris sp. eggs were recovered from human's faeces and inoculated into sewage samples. The viability of Ascaris sp. eggs was analyzed after exposure to 0.5 KGy, 1.0 KGy, 2.5 KGy, 5.0 KGy e 10 KGy. In addition, suspended solids were analyzed in order to verify the effect of solids content to the irradiation efficiency. Preliminary results indicated that for doses lower than 1.5 KGy, the efficiency of inactivation in the affluent was higher than the influent. It was also observed that doses above of 2.5 KGy had inactivated practically 100% of eggs of Ascaris sp. in the treated and untreated sewage samples. These results suggest that gamma irradiation can be used as an efficient technique to disinfect domestic sewage. (author)

  7. Efficiency evaluation of China's investment in Africa under the background of constructing "Silk Road Economic Belt": Application of DEA model and Malmquist index method

    OpenAIRE

    Ze, Tian; Yumei, Fan; Chao, Liu

    2018-01-01

    In recent years, with implementation and propulsion of the strategic planning "One Belt and One Road" of China, quality and efficiency of China's foreign direct investment have increasingly become a focused issue. This paper utilizes the DEA model and Malmquist index method to select the data of China's investment in 20 countries of Africa and conducts the empirical research on dynamic evaluation of efficiency of China's direct investment in Africa. The result shows that the general efficienc...

  8. In vitro germination and the effect of acute gamma irradiation on pollen of Pinus patula Schiede et Deppe

    International Nuclear Information System (INIS)

    Kapoor, M.L.; Dobriyal, N.D.

    1980-01-01

    In-vitro study revealed that the best medium for germinating P. patula pollen was 12,5% Sucrose with 0.001% Boron in 2% agar medium. After gamma irradiation the LD-50 based on pollen germination and germination energy index was 1.174 kr and 1.148 kr respectively. Pollen was viable on the 90th day when used after storing at 10 0 C in desiccator. Gamma doses for haploid breeding and mutation breeding are suggested. ANOVA showed that differences between the different media used for germination and gamma-ray doses were highly significant. (orig.) [de

  9. Distinguishing 'Higgs' spin hypotheses using {gamma}{gamma} and WW{sup *} decays

    Energy Technology Data Exchange (ETDEWEB)

    Ellis, John [King' s College London, Theoretical Particle Physics and Cosmology Group, Physics Department, London (United Kingdom); CERN, TH Division, Physics Department, Geneva (Switzerland); Fok, Ricky [York University, Department of Physics and Astronomy, Toronto, ON (Canada); Hwang, Dae Sung [Sejong University, Department of Physics, Seoul (Korea, Republic of); Sanz, Veronica [CERN, TH Division, Physics Department, Geneva (Switzerland); York University, Department of Physics and Astronomy, Toronto, ON (Canada); You, Tevong [King' s College London, Theoretical Particle Physics and Cosmology Group, Physics Department, London (United Kingdom)

    2013-07-15

    The new particle X recently discovered by the ATLAS and CMS Collaborations in searches for the Higgs boson has been observed to decay into {gamma}{gamma}, ZZ{sup *} and WW{sup *}, but its spin and parity, J{sup P}, remain a mystery, with J{sup P} = 0{sup +} and 2{sup +} being open possibilities. We use PYTHIA and Delphes to simulate an analysis of the angular distribution of gg {yields} X {yields} {gamma}{gamma} decays in a full 2012 data set, including realistic background levels. We show that this angular distribution should provide strong discrimination between the possibilities of spin zero and spin two with graviton-like couplings: {proportional_to}3 {sigma} if a conservative symmetric interpretation of the log-likelihood ratio (LLR) test statistic is used, and {proportional_to}6 {sigma} if a less conservative asymmetric interpretation is used. The WW and ZZ couplings of the Standard Model Higgs boson and of a 2{sup +} particle with graviton-like couplings are both expected to exhibit custodial symmetry. We simulate the present ATLAS and CMS search strategies for X {yields} WW{sup *} using PYTHIA and Delphes, and show that their efficiencies in the case of a spin-2 particle with graviton-like couplings are a factor {approx_equal} 1.9 smaller than in the spin-0 case. On the other hand, the ratio of X{sub 2{sup +}} {yields} WW{sup *} and ZZ{sup *} branching ratios is larger than that in the 0{sup +} case by a factor {approx_equal} 1.3. We find that the current ATLAS and CMS results for X {yields} WW{sup *} and X {yields} ZZ{sup *} decays are compatible with custodial symmetry under both the spin-0 and -2 hypotheses, and that the data expected to become available during 2012 are unlikely to discriminate significantly between these possibilities. (orig.)

  10. Comparison of the Gini and Zenga Indexes using Some Theoretical Income Distributions Abstract

    Directory of Open Access Journals (Sweden)

    Katarzyna Ostasiewicz

    2013-01-01

    Full Text Available The most common measure of inequality used in scientific research is the Gini index. In 2007, Zenga proposed a new index of inequality that has all the appropriate properties of an measure of equality. In this paper, we compared the Gini and Zenga indexes, calculating these quantities for the few distributions frequently used for approximating distributions of income, that is, the lognormal, gamma, inverse Gauss, Weibull and Burr distributions. Within this limited examination, we have observed three main differences. First, the Zenga index increases more rapidly for low values of the variation and decreases more slowly when the variation approaches intermediate values from above. Second, the Zenga index seems to be better predicted by the variation. Third, although the Zenga index is always higher than the Gini one, the ordering of some pairs of cases may be inverted. (original abstract

  11. Study of {gamma}'s in Naiade; Etude des gamma de Naiade

    Energy Technology Data Exchange (ETDEWEB)

    Millot, J P; Rastoin, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Following a study of the gamma sources, the flux of gamma of different energies in the swimming pool is investigated. The biological dose can thus be obtained by calculation, and compared with the results given by photographic plates. The influence of photoneutrons is estimated by calculation, and research is being carried out on their influence on the thermal neutron flux curve on the axis of the uranium plate, with the plate emitting neutrons and with the plate protected by boral. (author) [French] Apres l'etude des sources de gamma, l'on etudie le flux de gamma de differentes energies dans la piscine. La dose biologique peut etre obtenue ainsi par le calcul et comparee avec les resultats donnes par les plaques photographiques. L'influence des photoneutrons est estimee par le calcul et l'on recherche leur influence sur la courbe de flux de neutrons thermiques sur l'axe de la plaque d'uranium, la plaque emettant des neutrons et la plaque protegee par du boral. (auteur)

  12. Measurement of K{sup {+-}}{yields}{pi}{sup {+-}}{gamma}{gamma} decays

    Energy Technology Data Exchange (ETDEWEB)

    Morales Morales, Cristina

    2009-07-21

    The goal of this thesis was an experimental test of an effective theory of strong interactions at low energy, called Chiral Perturbation Theory (ChPT). Weak decays of kaon mesons provide such a test. In particular, K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma} decays are interesting because there is no tree-level O(p{sup 2}) contribution in ChPT, and the leading contributions start at O(p{sup 4}). At this order, these decays include one undetermined coupling constant, c. Both the branching ratio and the spectrum shape of K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma} decays are sensitive to this parameter. O(p{sup 6}) contributions to K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma} ChPT predict a 30-40% increase in the branching ratio. From the measurement of the branching ratio and spectrum shape of K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma} decays, it is possible to determine a model dependent value of c and also to examine whether the O(p{sup 6}) corrections are necessary and enough to explain the rate. About 40% of the data collected in the year 2003 by the NA48/2 experiment have been analyzed and 908 K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma} candidates with about 8% background contamination have been selected in the region with z=m{sup 2}{sub {gamma}}{sub {gamma}}/m{sub K}{sup 2}{>=}0.2. Using 5,750,121 selected K{sup {+-}} {yields} {pi}{sup {+-}}{pi}{sup 0} decays as normalization channel, a model independent differential branching ratio of K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma} has been measured to be: BR(K{sup {+-}} {yields} {pi}{sup {+-}}{gamma}{gamma}, z{>=}0.2)=(1.018{+-}0.038{sub stat}{+-}0.039{sub syst}{+-}0.004{sub ext}).10{sup -6}. From the fit to the O(p{sup 6}) ChPT prediction of the measured branching ratio and the shape of the z-spectrum, a value of c=1.54{+-}0.15{sub stat}{+-}0.18{sub syst} has been extracted. Using the measured c value and the O(p{sup 6}) ChPT prediction, the branching ratio for z=m{sup 2}{sub

  13. Synthesis, Characterization, and Nonlinear Optical Properties of P-Substituted Poly Gamma-Benzyl

    Science.gov (United States)

    Choi, Dong-Hoon

    Poly gamma-benzyl-L-glutamate (PBLG), poly gamma-p-fluorobenzyl -L-glutamate (PGLU(pFB)), poly gamma -p-nitrobenzyl-L-glutamate (PGLU(pNB)), and poly gamma-p-trifluoromethylbenzyl-L-glutamate (PGLU(pTFMB)) have been synthesized. These PBLG polymers show variations in the side chain conformations in the solid state and solution state. In the solid state, the side chain orientation was assigned to a longitudinal or transverse direction by virtue of the polarized infrared spectrum of each PBLG analogue. The characteristics of the lyotropic liquid crystalline behavior could be observed. The optical waveguiding property of these polymers facilitated measurement of the refractive index and the thickness of each polymer film. Poling the polymer films and using the simple reflection technique, the electro -optic coefficients of the PBLG analogues could be determined. The effect of the para substitution on benzyl ester as it effected the electro-optic coefficient and the relation between the dielectric properties and the electro-optic effect of each polymer were investigated. These studies were able to demonstrate which conformation of the side chain in para substituted poly gamma-benzyl -L-glutamates is a more favorable conformation for enhancing the electro-optic behavior of these polymers.

  14. Orbital Normalization of MESSENGER Gamma-Ray Spectrometer Data

    Science.gov (United States)

    Rhodes, E. A.; Peplowski, P. N.; Evans, L. G.; Hamara, D. K.; Boynton, W. V.; Solomon, S. C.

    2011-12-01

    The MESSENGER Gamma-Ray Spectrometer (GRS) measures energy spectra of gamma rays emanating from the surface of Mercury. Analysis of these spectra provides elemental abundances of surface material. The MESSENGER mission necessarily provides some data normalization challenges for GRS analysis. So as to keep the spacecraft cool while orbiting the dayside of the planet, the orbits are highly eccentric, with altitudes varying from 200-500 km to ~ 15,000 km. A small fraction of time is spent at the low altitudes where gamma-ray signals are largest, requiring a large number of orbits to yield sufficient counting statistics for elemental analysis. Also, the sunshade must always shield the spacecraft from the Sun, which causes the orientation of the GRS often to be far from nadir-pointing, so the detector efficiency and attenuation of gamma rays from the planet must be known for a wide range of off-nadir orientations. An efficiency/attenuation map for the expected ranges of orientations and energies was constructed in a ground calibration experiment for a limited range of orientations using a nuclear reactor and radioisotope sources, and those results were extended to other orientations by radiation transport computations using as input a computer-aided design model of the spacecraft and its composition. This normalization has allowed abundance determinations of elements K, Th, and U from radioisotopes of these elements in the Mercury regolith during the first quarter of the year-long mission. These results provide constraints on models of Mercury's chemical and thermal evolution. The normalization of gamma-ray spectra for surface elements not having radioisotopes is considerably more complex; these gamma rays come from neutron inelastic-scatter and capture reactions in the regolith, where the neutrons are generated by cosmic ray impact onto the planet. A radiation transport computation was performed to generate the expected count rates in the neutron-generated gamma

  15. Estimation of track registration efficiency in solution medium and study of gamma irradiation effects on the bulk-etch rate and the activation energy for bulk etching of CR-39 (DOP) Solid State Nuclear Track Detector

    International Nuclear Information System (INIS)

    Kalsi, P.C.

    2010-01-01

    The fission track registration efficiency of diethylene glycol bis allyl carbonate (dioctyl phthalate doped) (CR-39 (DOP)) solid state nuclear track detector (SSNTD) in solution medium (K wet ) has been experimentally determined and is found to be (9.7 ± 0.5).10 -4 cm. This is in good agreement with the values of other SSNTDs. The gamma irradiation effects in the dose range of 50.0-220.0 kGy on the bulk etch rate, V b and the activation energy for bulk etching, E of this solid state nuclear track detector (SSNTD) have also been studied. It is observed that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation

  16. Study The Validity of The Direct Mathematical Method For Calculation The Total Efficiency Using Point And Disk Sources

    International Nuclear Information System (INIS)

    Hagag, O.M.; Nafee, S.S.; Naeem, M.A.; El Khatib, A.M.

    2011-01-01

    The direct mathematical method has been developed for calculating the total efficiency of many cylindrical gamma detectors, especially HPGe and NaI detector. Different source geometries are considered (point and disk). Further into account is taken of gamma attenuation from detector window or any interfacing absorbing layer. Results are compared with published experimental data to study the validity of the direct mathematical method to calculate total efficiency for any gamma detector size.

  17. Proposed computerized cross-index system for storage and retrieval ...

    African Journals Online (AJOL)

    Card index systems are normally not very efficient when used for cross-indexing purposes and information retrieval, useful information frequently being lost because of poor indexing and little or no cross-referencing. Large card index systems are often compiled by research workers but these potentially useful stores of ...

  18. Efficacy of gamma irradiation on H5N1 for the preparation of hemagglutination Inhibition test antigen

    International Nuclear Information System (INIS)

    Chaisingh, Arunee; Thammasart, Suree; Kamolsiripichaiporn, Somjai; Piadang Nattayana

    2006-09-01

    The result of the efficiencies of gamma irradiation at the dose of 10-60 kGy on highly pathogenic avian influenza virus, H5N1 (Thai isolate) revealed that gamma irradiation at the dose of 10 and 20 kGy could reduce the infectivity of Hanna but gamma irradiation at 30-60 kGy could inactivate H5N1 virus completely. All doses of gamma irradiation used in this experiment had no effect on antigenicity of hemagglutinin protein. Thus, gamma irradiation at the dose of 30- 60 kGy could be use safely for the antigen preparation to detect the antibody against H5N1 virus.

  19. Toward standardising gamma camera quality control procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  20. Multi-Level Bitmap Indexes for Flash Memory Storage

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kesheng; Madduri, Kamesh; Canon, Shane

    2010-07-23

    Due to their low access latency, high read speed, and power-efficient operation, flash memory storage devices are rapidly emerging as an attractive alternative to traditional magnetic storage devices. However, tests show that the most efficient indexing methods are not able to take advantage of the flash memory storage devices. In this paper, we present a set of multi-level bitmap indexes that can effectively take advantage of flash storage devices. These indexing methods use coarsely binned indexes to answer queries approximately, and then use finely binned indexes to refine the answers. Our new methods read significantly lower volumes of data at the expense of an increased disk access count, thus taking full advantage of the improved read speed and low access latency of flash devices. To demonstrate the advantage of these new indexes, we measure their performance on a number of storage systems using a standard data warehousing benchmark called the Set Query Benchmark. We observe that multi-level strategies on flash drives are up to 3 times faster than traditional indexing strategies on magnetic disk drives.

  1. Multiwire proportional gamma camera for imaging /sup 99/Tcsup(m) radionuclide distributions

    Energy Technology Data Exchange (ETDEWEB)

    Bateman, J E; Connolly, J F [Science Research Council, Chilton (UK). Rutherford Lab.

    1978-05-01

    A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm) showing good imaging of /sup 99/Tcsup(m) radionuclide distributions and confirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area > approximately 3 1m/sup 2/, a quantum efficiency of 15% and a spatial resolution approximately 3 mm, whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronics industry. This apparatus is covered by patent application number 26595/77.

  2. A multiwire proportional gamma camera for imaging 99Tcsup(m) radionuclide distributions

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.

    1978-01-01

    A gamma camera made of multiple multiwire proportional chambers with thin converter foils has been evaluated for clinical application. Results are presented from a small prototype (10 cm x 10 cm) showing good imaging of 99 Tcsup(m) radionuclide distributions and confirming the predictions of the theory regarding quantum efficiency and spatial resolution. The technique is especially aimed at creating a gamma camera with an active area > approximately 3 1m 2 , a quantum efficiency of 15% and a spatial resolution approximately 3 mm, whole body scanning and tomographic applications. The results generated by the current prototype indicate that the above requirements can be met using relatively cheap mass production techniques from the electronics industry. This apparatus is covered by patent application number 26595/77. (author)

  3. Physical changes associated with gamma doses of PM-555 solid-state nuclear track detector

    International Nuclear Information System (INIS)

    Nouh, S.A.

    2004-01-01

    The effect of gamma irradiation on the electrical, molecular and structural properties of copolymers of methacrylic esters and olefins, PM-555 solid-state nuclear track detector was investigated. DC conductivity measurements were studied in the temperature range 293-417 K using solid-state samples of the PM-555 polymer. These samples were irradiated with gamma doses in the range 5-63 kGy. Furthermore, the activation energy was measured, at various temperatures, as a function of the gamma dose. It was found that many changes in electrical resistance of PM-555 polymer could be produced by gamma irradiation via the degradation mechanism. Also, the gamma dose gives an advantage for the increasing correlation between the DC conductivity and the number and mobility of the charge carriers created by the ionizing effect of gamma radiation. Moreover, solutions of different loadings (0.2%, 0.4%, 0.6% and 0.8%) were prepared from the irradiated and non irradiated sheets using pure chloroform as a solvent. The effect of both temperature and gamma dose on the intrinsic viscosity of the liquid samples, as a measure of the mean molecular mass of the PM-555 polymer, were studied. In addition, structural and optical property studies using X-ray diffraction and refractive index measurements were performed on all irradiated and non irradiated PM-555 samples. The results indicate that both the degree of ordering or disordering and the anisotropic character of the PM-555 polymer are dependent on the gamma dose

  4. Protective effect and the therapeutic index of indralin in juvenile rhesus monkeys

    International Nuclear Information System (INIS)

    Vasin, Mikhail V.; Antipov, Vsevolod V.; Ushakov, Igor B.; Semenov, Leonid F.; Lapin, Boris A.; Suvorov, Nikolai N.; Ilyin, Leonid A.

    2014-01-01

    The radioprotective effect of indralin in rhesus monkeys was examined over 60 d following gamma irradiation. Male and female rhesus macaques (Macaca mulatta) 2-3-years-old and weighing 2.1-3.5 kg were used. Animals were exposed to total-body gamma irradiation from 60 Co at a dose of 6.8 Gy (lethal dose, 100% lethality over 30 days). Indralin (40-120 mg kg -1 ) was administered intramuscularly 5 min prior to radiation exposure. Indralin taken at a dose of 120 mg kg -1 protected five out of six monkeys (compared with the radiation control group, in which all 10 animals died). The average effective dose of indralin in the monkeys exposed to gamma irradiation for 30 min was equal to 77.3 (63.3-94.3) mg kg -1 , and the maximum tolerated dose of indralin administered to monkeys was 800 mg kg -1 . Indralin reduced radiation-induced injuries in macaques, thus resulting in a less severe course of acute radiation syndrome. Delayed and less pronounced manifestation of the haemorrhagic syndrome of the disease, and milder forms of both leukopenia and anaemia were also noted. The therapeutic index for indralin, expressed as the ratio of the maximum tolerated dose to the average effective dose, was equal to 10. Therefore, indralin has a significant radioprotective effect against radiation and has a high therapeutic index in rhesus monkeys. (author)

  5. An electronic interface for acquisition of 12 delayed gamma-gammacoincidence spectra

    International Nuclear Information System (INIS)

    Domienikan, Claudio

    2001-01-01

    An electronic interface has been constructed to be used m conjunctionwith a Time differential Perturbed gamma-gamma Angular Correlation (TDPAC)spectrometer with four BaF 2 detectors. The routing interface is speciallydesigned to work with the Ortec model ADCAM 920-16 multichannel analyzer(MCA) having 16 multiplexed inputs, permitting the simultaneous acquisitionof 12 delayed gamma-gamma coincidence spectra. This innovation provides aconsiderable reduction in the experimental data acquisition time and as aconsequence permits an improvement in the precision of the final results ofthe hyperfine parameters deduced from the TDPAC measurements. The interfaceconsists of two distinct electronic circuits. A novel high performance analogdemultiplexer circuit is used to address the linear pulses from the time toamplitude converter (TAC) to the corresponding MCA inputs, according to thepair of detectors responsible for the given gamma-gamma coincidence.Validation of the gamma-gamma coincidence and control of the analogdemultiplexer are realized by a digital circuit, consisting basically ofmonostable multivibrators and decoders of High-Speed CMOS Logic (HCT). Theperformance of the routing interface was evaluated through several testmeasurements which included the time resolution and linearity of the system,the quadrupolar interaction in 181 Ta(Hf), 181 Ta(HfO 2 ), 111 Cd(Cd)and 111 Cd(Pd) samples, and the hyperfine magnetic field in 181 'Ta(Ni), 11 '1Cd(Ni) and 140 Ce(Gd) samples. The results of the hyperfineinteraction measurements are discussed and compared with previous results andserve to demonstrate the correct and efficient performance of the constructedinterface. (author)

  6. Gamma ray generator

    Science.gov (United States)

    Firestone, Richard B; Reijonen, Jani

    2014-05-27

    An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

  7. An intercomparison of Monte Carlo codes used for in-situ gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Hurtado, S.; Villa, M.

    2010-01-01

    In-situ gamma-ray spectrometry is widely used for monitoring of natural as well as man-made radionuclides and corresponding gamma fields in the environment or working places. It finds effective application in the operational and accidental monitoring of nuclear facilities and their vicinity, waste depositories, radioactive contamination measurements and environmental mapping or geological prospecting. In order to determine accurate radionuclide concentrations in these research fields, Monte Carlo codes have recently been used to obtain the efficiency calibration of in-situ gamma-ray detectors. This work presents an inter-comparison between two Monte Carlo codes applied to in-situ gamma-ray spectrometry. On the commercial market, Canberra has its LABSOCS/ISOCS software which is relatively inexpensive. The ISOCS mathematical efficiency calibration software uses a combination of Monte Carlo calculations and discrete ordinate attenuation computations. Efficiencies can be generated in a few minutes in the field and can be modified easily if needed. However, it has been reported in the literature that ISOCS computation method is accurate on average only within 5%, and additionally in order to use LABSOCS/ISOCS it is necessary a previous characterization of the detector by Canberra, which is an expensive process. On the other hand, the multipurpose and open source GEANT4 takes significant computer time and presents a non-friendly but powerful toolkit, independent of the manufacturer of the detector. Different experimental measurements of calibrated sources were performed with a Canberra portable HPGe detector and compared to the results obtained using both Monte Carlo codes. Furthermore, a variety of efficiency calibrations for different radioactive source distributions were calculated and tested, like plane shapes or containers filled with different materials such as soil, water, etc. LabSOCS simulated efficiencies for medium and high energies were given within an

  8. The design and construction of a scintillation pair spectrometer for the detection of {gamma}-rays in the energy range 2-20 MeV; Realisation d'un spectrometre a scintillations et a paires pour la detection des rayonnements {gamma} d'energie comprise entre 2 et 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Longequeue, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-15

    The scintillation pair spectrometer is designed to allow the measurement of the energy of {gamma} rays in the range 2 to 20 MeV. Such an instrument is chosen because of its main features: high energy resolution and ease of working. Against this, however, the efficiency is low. It was possible to tolerate this low efficiency because of the facts that the {gamma}-rays studied emanated from (p, {gamma}) reactions and that the two electrostatic acceleration available could provide beams of 500 {mu}A having energy maxima at 300 and 600 keV. We used the {gamma} rays produced by the reactions {sup 23}Na (p, {gamma}) {sup 24}Mg, {sup 19}F (p, {alpha} {gamma}) {sup 16}O and {sup 7}Li (p, {gamma}) {sup 8}Be as well as the {gamma} rays emitted by sources of RTh and of {sup 24}Na. Under these conditions the spectrometer attained a resolving power of 6,5 {+-} 0,5 per cent at 6,1 MeV and it was able to separate the 14,8 and 17,6 MeV lines produced by the reaction {sup 7}Li (p, {gamma}) {sup 8}Be. As well as this, the efficiency which varied from 2.10{sup -4} to 1,7.10{sup -3} between 2 and 20 MeV was well above the efficiencies already obtained with this type of instrument. (author) [French] Le spectrometre a scintillations et a paires presente dans cette these a pour but de mesurer l'energie des rayonnements {gamma} dans la bande de 2 a 20 MeV. Le choix d'un tel appareil est du a ses caracteristiques essentielles: bonne resolution en energie et maniabilite. Par contre, son efficacite est faible. Nous avons pu tolerer cette faible efficacite car les rayonnements {gamma} que nous avons etudies provenaient de reactions (p, {gamma}) et les deux accelerateurs electrostatiques dont nous disposions pouvaient fournir des faisceaux de 500 {mu}A avec des energies maximum de 300 et 600 keV. Nous avons utilise les rayonnements {gamma} produits par les reactions {sup 23}Na (p, {gamma}) {sup 24}Mg, {sup 19}F (p, {alpha} {gamma}) {sup 16}O et {sup 7}Li (p, {gamma}) {sup 8}Be ainsi que les

  9. Constraints on Cosmic Rays, Magnetic Fields, and Dark Matter from Gamma-ray Observations of the Coma Cluster of Galaxies with VERITAS and FERMI

    Science.gov (United States)

    Arlen, T.; Aune, T.; Beilicke, M.; Benbow, W.; Bouvier, A.; Buckley, J. H.; Bugaev, V.; Byrum, K.; Cannon, A.; Cesarini, A.; hide

    2012-01-01

    Observations of radio halos and relics in galaxy clusters indicate efficient electron acceleration. Protons should likewise be accelerated and, on account of weak energy losses, can accumulate, suggesting that clusters may also be sources of very high energy (VHE; E greater than100 GeV) gamma-ray emission. We report here on VHE gamma-ray observations of the Coma galaxy cluster with the VERITAS array of imaging Cerenkov telescopes, with complementing Fermi Large Area Telescope observations at GeV energies. No significant gamma-ray emission from the Coma Cluster was detected. Integral flux upper limits at the 99 confidence level were measured to be on the order of (2-5) x 10(sup -8) photons m(sup -2) s(sup -1) (VERITAS,greater than 220 GeV) and approximately 2 x 10(sup -6) photons m(sup -2) s(sup -1) (Fermi, 1-3 GeV), respectively. We use the gamma-ray upper limits to constrain cosmic rays (CRs) and magnetic fields in Coma. Using an analytical approach, the CR-to-thermal pressure ratio is constrained to be less than 16% from VERITAS data and less than 1.7% from Fermi data (averaged within the virial radius). These upper limits are starting to constrain the CR physics in self-consistent cosmological cluster simulations and cap the maximum CR acceleration efficiency at structure formation shocks to be 50. Alternatively, this may argue for non-negligible CR transport processes such as CR streaming and diffusion into the outer cluster regions. Assuming that the radio-emitting electrons of the Coma halo result from hadronic CR interactions, the observations imply a lower limit on the central magnetic field in Coma of approximately (2-5.5)microG, depending on the radial magnetic field profile and on the gamma-ray spectral index. Since these values are below those inferred by Faraday rotation measurements in Coma (for most of the parameter space), this renders the hadronic model a very plausible explanation of the Coma radio halo. Finally, since galaxy clusters are dark

  10. Study on the sterilization of canned water melon by gamma irradiation

    International Nuclear Information System (INIS)

    Kim, B.M.

    1978-01-01

    In order to study the effects of gamma-irradiations on the storage life of canned water melon, the contents of canning water melon were controlled pH to 4.0 and 5.0 by adding some kinds of organic acids such as citric acid, tartaric acid, and ascorbic acid, respectively. The pH controlled water melons were canned, followed by being exposed to 0.25, 0.5, and 1.0 Mrads of gamma-ray, respectively. The results were as follows: In non-acid canned water melon, the higher doses of radiation induced the more efficiency on the extension of storage life of it even if the efficiency was mot so great. By irradiations of 1.0 Mrads, it could be kept for 15 days without any deterioration. By means of the addition of organic acids, the radiation effect on the extension of the storage life of the above food increased remarkably. In particular, the water melon cans with ascorbic acid (pH 4.0) could be kept for 60 days without any deterioration by gamma-irradiation of 0.5 and 1.0 Mrads. (Author)

  11. SPATIAL AND SPECTRAL MODELING OF THE GAMMA-RAY DISTRIBUTION IN THE LARGE MAGELLANIC CLOUD

    Energy Technology Data Exchange (ETDEWEB)

    Foreman, Gary; Chu, You-Hua; Gruendl, Robert; Fields, Brian; Ricker, Paul [Department of Astronomy, University of Illinois, 1002 W. Green St., Urbana, IL 61801 (United States); Hughes, Annie, E-mail: gforema2@illinois.edu [Max-Planck-Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany)

    2015-07-20

    We perform spatial and spectral analyses of the LMC gamma-ray emission collected over 66 months by the Fermi Gamma-ray Space Telescope. In our spatial analysis, we model the LMC cosmic-ray distribution and gamma-ray production using observed maps of the LMC interstellar medium, star formation history, interstellar radiation field, and synchrotron emission. We use bootstrapping of the data to quantify the robustness of spatial model performance. We model the LMC gamma-ray spectrum using fitting functions derived from the physics of π{sup 0} decay, Bremsstrahlung, and inverse Compton scattering. We find the integrated gamma-ray flux of the LMC from 200 MeV to 20 GeV to be 1.37 ± 0.02 × 10{sup −7} ph cm{sup −2} s{sup −1}, of which we attribute about 6% to inverse Compton scattering and 44% to Bremsstrahlung. From our work, we conclude that the spectral index of the LMC cosmic-ray proton population is 2.4 ± 0.2, and we find that cosmic-ray energy loss through gamma-ray production is concentrated within a few 100 pc of acceleration sites. Assuming cosmic-ray energy equipartition with magnetic fields, we estimate LMC cosmic rays encounter an average magnetic field strength ∼3 μG.

  12. Radiation-induced reduction of diuron by gamma-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jibiao [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Zheng Zheng [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China)], E-mail: zzheng@nju.edu.cn; Zhao Tan [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Zhao Yongfu [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China); Institute of Atomic Energy, Jiangsu Academy of Agriculture Sciences, Nanjing 210014 (China); Wang Lianhong; Zhong Yun; Xu Yue [State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210093 (China)

    2008-03-01

    Diuron degradation efficiencies and the proposed mechanism by gamma-ray irradiation were investigated. Several factors that might affect the degradation values were further examined. The UV absorbances at 200-400 nm and diuron concentration decreased with the increase of radiation dose. When diuron initial concentration was 18.5 mg L{sup -1} and 1.0 kGy was selected as the radiation dose, diuron removal value and loss of total organic carbon were 100 and 34.1%, respectively. However, the concentration of Cl{sup -} ion increased with the increase of radiation dose. The process could be depicted by first order reaction kinetics and the reaction was mainly caused by the reaction of diuron with {center_dot}OH and e{sub aq}{sup -}. The degradation efficiency decreased with the increase of initial concentration at the same radiation dose. H{sub 2}O{sub 2}, HCO{sub 3}{sup -}, NO{sub 3}{sup -}, NO{sub 2}{sup -}, CH{sub 3}OH and humic acid as additives reduced the degradation efficiency. Furthermore, the increase of NO{sub 3}{sup -}, NO{sub 2}{sup -}, CH{sub 3}OH and humic acid would result in the decrease of the degradation values. The pH value could affect the removal efficiency and the degradation process was enhanced in acid condition. The pH value became lower with increasing radiation dose after gamma-ray irradiation.

  13. Measuring highway efficiency : A DEA approach and the Malquist index

    NARCIS (Netherlands)

    Sarmento, Joaquim Miranda; Renneboog, Luc; Verga-Matos, Pedro

    A growing concern exists regarding the efficiency of public resources spent in transport infrastructures. In this paper, we measure the efficiency of seven highway projects in Portugal over the past decade by means of a data envelopment analysis and the Malmquist productivity and efficiency indices.

  14. Disinfection of sewage water and sludge using gamma radiation

    International Nuclear Information System (INIS)

    Musaad, R.M.A.

    2008-04-01

    This study has been carried out to assess the efficiency of gamma radiation in disinfecting sewage water and sludge from harmful pathogenic bacteria (e.g. Streptococcus, Salmonella, Shigella, total E-coli and total coliform), parasites (Ascaris ova) as well as its ability to degrade organic matter (BOD). Samples were exposed to gamma-radiation doses ranging from 0.5 to 8 KGy using Co''6 0 cell. Amongst pathogenic bacteria which are subjected to different doses of gamma-radiation Streptococcus faecalis revealed to be the most resistance bacterial indicator since complete elimination of these bacteria could be attained at 3.5 KGy. While total e-coli shown to be the most sensitive with lethal dose at 2 KGy. The radiation doses that required for reducing the bacterial population by 90% (D 10 ) and 50% (D 50 ) were determined for each species. The D 10 values found ranged from 0.75 KGy for Streptococcus and 2.75 KGy for total count bacteria. On the other hand, D 50 fall within the range of 0.5 KGy for total count bacteria, total coliform and Streptococcus, and 1.0 KGy for total e-coli. With regard to the efficiency of radiation treatment to destroy Ascaris ova viability it was found that no larvae were viable after exposure to 1.0 KGy following incubation of exposed ova for four weeks period.(Author)

  15. Effects of gamma ray irradiation on the struvite crystallization of livestock wastewater

    International Nuclear Information System (INIS)

    Yoo, Byeong Hak; Jo, Seong Hui; Lee, Myun Joo; Kim, Tak Hyun

    2010-01-01

    The struvite crystallization was applied to remove NH 4 + in livestock wastewater. The ammonium ions can be very toxic to the aquatic creatures. In this experiments, the livestock wastewater from Gongju livestock wastewater treatment plant was used. The behaviors of various parameters such as pH, mole ratio of Mg 2+ : NH 4 + : PO 4 3- and reaction temperature for struvite crystallization of livestock wastewater and the effect of gamma ray irradiation were evaluated. As results, for the pH variation, the NH 4 + removal efficiency showed the highest, 88%, at pH 9 ∼ 9.25. The removal efficiency of NH 4 + , Mg 2+ and PO 4 3- was showed highest when same molar ratio of Mg 2+ and PO 4 3- were applied. The NH 4 + removal efficiency showed 82% at 7 .deg. C, and 90% at 30 .deg. C, with temperature. When the wastewater was irradiated with 20 kGy of gamma ray, NH 4 + was removed as much as 83%

  16. Multi-dimensional analysis of high resolution {gamma}-ray data

    Energy Technology Data Exchange (ETDEWEB)

    Flibotte, S.; Huettmeier, U.J.; France, G. de; Haas, B.; Romain, P.; Theisen, Ch.; Vivien, J.P.; Zen, J. [Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires

    1992-12-31

    A new generation of high resolution {gamma}-ray spectrometers capable of recording high-fold coincidence events with a large efficiency will soon be available. Algorithms are developed to analyze high-fold {gamma}-ray coincidences. As a contribution to the software development associated with the EUROGAM spectrometer, the performances of computer codes designed to select multi-dimensional gates from 3-, 4- and 5-fold coincidence databases were tested. The tests were performed on events generated with a Monte Carlo simulation and also on real experimental triple data recorded with the 8{pi} spectrometer and with a preliminary version of the EUROGAM array. (R.P.) 14 refs.; 3 figs.; 3 tabs.

  17. On self-attenuation corrections in gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Bolivar, J.P.; Garcia-Leon, M.; Garcia-Tenorio, R.

    1997-01-01

    In this paper we discuss and justify the dependence on the sample density and gamma energy of the self-attenuation correction factor, f, in the transmission method for the full energy peak efficiency calibration of Ge detectors. It is suggested as a method for the direct computing of f in the case that the sample composition is known. (Author)

  18. Calibration and testing of the DMG gamma dosimeter

    International Nuclear Information System (INIS)

    Dolgirev, E.I.

    1987-01-01

    25-1000 nGy/h (2.5-1000 μrad/h) absorbed dose gamma dosimeter for measuring the efficient equivalent irradiation dose for population is developed. It has two subranges 1000 nGy/h and 250 nGy/h. Results of dosimeter calibration and testing are presented. The dosimeter error for both subranges is less than 10%

  19. Determination of natural radioactivity in building materials used in Tunisian dwellings by gamma ray spectrometry

    International Nuclear Information System (INIS)

    Hizem, N.; Fredj, A. B.; Ghedira, L.

    2005-01-01

    The radioisotopic content of 17 samples of natural and manufactured building materials collected in Tunisia have been analysed by using gamma spectrometry. From the measured gamma ray spectra, activity concentrations are determined for 232 Th, 226 Ra, 235 U and 40 K. The total effective dose and the activity concentration index are calculated applying the dose criteria recommended by the European Union for building materials. The results of 226 Ra, 232 Th and 40 K found in Tunisian building materials indicate that radium and thorium concentrations do not exceed 40 Bq kg -1 , but potassium concentration varies between 50 and 1215 Bq kg -1 . The total effective dose rates per person indoors are determined to be between 0.07 and 0.86 mSv y -1 . Only two materials exceed the reference level of 0.3 mSv y -1 . The activity concentration index is <1. (authors)

  20. Low energy spectral index and Ep evolution of quasi-thermal photosphere emission of gamma-ray bursts

    International Nuclear Information System (INIS)

    Deng, Wei; Zhang, Bing

    2014-01-01

    Recent observations by the Fermi satellite suggest that a photosphere emission component is contributing to the observed spectrum of many gamma-ray bursts (GRBs). One important question is whether the photosphere component can interpret the typical 'Band' function of GRBs with a typical low energy photon spectral index α ∼ –1. We perform a detailed study of the photosphere emission spectrum by progressively introducing several physical ingredients previously not fully incorporated, including the probability distribution of the location of a dynamically evolving photosphere, superposition of emission from an equal arrival time 'volume' in a continuous wind, the evolution of optical depth of a wind with finite but evolving outer boundary, as well as the effect of different top-hat wind luminosity (L w ) profiles. By assuming a comoving blackbody spectrum emerging from the photosphere, we find that for an outflow with a constant or increasing L w , the low-energy spectrum below the peak energy (E p ), can be modified to F ν ∼ ν 1.5 (α ∼ +0.5). A softer (–1 < α < +0.5) or flat (α = –1) spectrum can be obtained during the L w decreasing phase or high-latitude-emission-dominated phase. We also study the evolution of E p as a function of wind and photosphere luminosity in this photosphere model. An E p – L tracking pattern can be reproduced if a certain positive dependence between the dimensionless entropy η and L w is introduced. However, the hard-to-soft evolution pattern cannot be reproduced unless a contrived condition is invoked. In order to interpret the Band spectrum, a more complicated photosphere model or a different energy dissipation and radiation mechanism is needed.

  1. DISCOVERY OF TeV GAMMA-RAY EMISSION FROM CTA 1 BY VERITAS

    Energy Technology Data Exchange (ETDEWEB)

    Aliu, E.; Errando, M. [Department of Physics and Astronomy, Barnard College, Columbia University, NY 10027 (United States); Archambault, S. [Physics Department, McGill University, Montreal, QC H3A 2T8 (Canada); Arlen, T. [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States); Aune, T.; Bouvier, A. [Santa Cruz Institute for Particle Physics and Department of Physics, University of California, Santa Cruz, CA 95064 (United States); Beilicke, M.; Buckley, J. H.; Bugaev, V.; Dickherber, R. [Department of Physics, Washington University, St. Louis, MO 63130 (United States); Benbow, W. [Fred Lawrence Whipple Observatory, Harvard-Smithsonian Center for Astrophysics, Amado, AZ 85645 (United States); Cesarini, A.; Connolly, M. P. [School of Physics, National University of Ireland Galway, University Road, Galway (Ireland); Ciupik, L. [Astronomy Department, Adler Planetarium and Astronomy Museum, Chicago, IL 60605 (United States); Collins-Hughes, E. [School of Physics, University College Dublin, Belfield, Dublin 4 (Ireland); Cui, W. [Department of Physics, Purdue University, West Lafayette, IN 47907 (United States); Duke, C. [Department of Physics, Grinnell College, Grinnell, IA 50112-1690 (United States); Dumm, J. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Dwarkadas, V. V. [Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL 60637 (United States); Falcone, A., E-mail: muk@astro.columbia.edu, E-mail: smcarthur@ulysses.uchicago.edu [Department of Astronomy and Astrophysics, 525 Davey Lab, Pennsylvania State University, University Park, PA 16802 (United States); and others

    2013-02-10

    We report the discovery of TeV gamma-ray emission coincident with the shell-type radio supernova remnant (SNR) CTA 1 using the VERITAS gamma-ray observatory. The source, VER J0006+729, was detected as a 6.5 standard deviation excess over background and shows an extended morphology, approximated by a two-dimensional Gaussian of semimajor (semiminor) axis 0. Degree-Sign 30 (0. Degree-Sign 24) and a centroid 5' from the Fermi gamma-ray pulsar PSR J0007+7303 and its X-ray pulsar wind nebula (PWN). The photon spectrum is well described by a power-law dN/dE = N {sub 0}(E/3 TeV){sup -{Gamma}}, with a differential spectral index of {Gamma} = 2.2 {+-} 0.2{sub stat} {+-} 0.3{sub sys}, and normalization N {sub 0} = (9.1 {+-} 1.3{sub stat} {+-} 1.7{sub sys}) Multiplication-Sign 10{sup -14} cm{sup -2} s{sup -1} TeV{sup -1}. The integral flux, F {sub {gamma}} = 4.0 Multiplication-Sign 10{sup -12} erg cm{sup -2} s{sup -1} above 1 TeV, corresponds to 0.2% of the pulsar spin-down power at 1.4 kpc. The energetics, colocation with the SNR, and the relatively small extent of the TeV emission strongly argue for the PWN origin of the TeV photons. We consider the origin of the TeV emission in CTA 1.

  2. Evaluation of optical fibres as gamma radiation dosimeter

    International Nuclear Information System (INIS)

    Bohra, Dinesh; Chaudhary, H.S.; Panwar, Lalit; Vaijapurkar, S.G.; Bhatnagar, P.K.; Dasgupta, K.

    2005-01-01

    Semiconductor base gamma and neutron sensors are the fastest and popular dosimeters and are in competition with Thermoluminescence (TL) and Radio photoluminescence (RPL) dosimeters. All over the world armed forces require a dosimeter which records cumulative doses of ionizing radiations from mcGy to 10 Gy and is readable repeatedly without loss of dose information. TL dosimeters do not meet the criteria and RPL dosimeter meet the expectations and are in use by armed forces. Technologists have used laser as an excitation source to stimulate the glass and have achieved success in recording gamma doses of occupational/accidental span (mcGy to 10 Gy). However synthesizing RPL glass batches with exactly same characteristics predoses is a difficult task. Silicon base phosphorous doped step index multimode optical fibre can be made in a significant quantity and large number of dosimeters from it can be achieved with uniform predose. The radiation induced transmission loss gives a measure of gamma dose which is cumulative, readable repeatedly without loss of information. Assorted composition, core dia optical fibres have been synthesized and evaluated for dose linearity, dose rate independence, fading, length optimization. Here in is described some results of recent experiments and sensitivities achieved. (author)

  3. Positron Annihilation Induced Auger and Gamma Spectroscopy of Catalytically Important Surfaces

    Science.gov (United States)

    Weiss, A. H.; Nadesalingam, M. P.; Sundaramoorthy, R.; Mukherjee, S.; Fazleev, N. G.

    2006-10-01

    The annihilation of positrons with core electrons results in unique signatures in the spectra of Auger-electron and annihilation-gamma rays that can be used to make clear chemical identification of atoms at the surface. Because positrons implanted at low energies are trapped with high efficiency in the image-correlation well where they are localized just outside the surface it is possible to use annihilation induced Auger and Gamma signals to probe the surfaces of solids with single atomic layer depth resolution. In this talk we will report recent applications of Positron Annihilation Induced Auger Electron Spectroscopy (PAES) and Auger-Gamma Coincidence Spectroscopy (AGCS) to the study of surface structure and surface chemistry. Our research has demonstrated that PAES spectra can provide new information regarding the composition of the top-most atomic layer. Applications of PAES to the study of catalytically important surfaces of oxides and wide band-gap semiconductors including TiO2, SiO2,Cu2O, and SiC will be presented. We conclude with a discussion of the use of Auger-Gamma and Gamma-Gamma coincidence spectroscopy for the study of surfaces at pressures closer to those found in practical chemical reactors. Research supported by the Welch Foundation Grant Number Y-1100.

  4. Verification of Gamma-ray Sensitivity for BF3 Neutron Detection System

    International Nuclear Information System (INIS)

    Choi, Yu Sun; Cho, Jin Bok; Lyou, Seok Jean

    2016-01-01

    The BF3(Boron Tri-Fluorides) gas filled neutron detector(hereafter BF3 Detector) is commonly used for nuclear reactor’s startup channel due to its relatively high neutron efficiency and good discrimination against gamma-ray backgrounds. In order to measure how much this gamma-ray will affect on BF3 neutron detector performance in view of gamma noise discrimination, Multi-Channel Analyzer(MCA) is utilized for spectrum based signal analysis. The pre-test of BF3 Detector should be performed in an area where the ionization does not exceed 2.5 micro Gy/Hr(Ref.1). In this paper, the discrimination level (Voltage Unit) is verified by experimentally measurement if that discrimination level is acceptable within the criteria or not before installation. The maximum discrimination level, so called LLD, is determined by experimentally measurement. This BF3 Detector (LND20372) is insensitive under 540 micro Gy/Hr of gamma ray and 0.3V of LLD could cut off a background and gamma induced signal in a laboratory. MCA could be a convenient tool for spectrum analysis of signals that induced from gamma ray and a time saving tool rather than oscilloscope investigation due to its function to integrate all input signals at a sudden duration

  5. A Study of the Efficiency of Spatial Indexing Methods Applied to Large Astronomical Databases

    Science.gov (United States)

    Donaldson, Tom; Berriman, G. Bruce; Good, John; Shiao, Bernie

    2018-01-01

    Spatial indexing of astronomical databases generally uses quadrature methods, which partition the sky into cells used to create an index (usually a B-tree) written as database column. We report the results of a study to compare the performance of two common indexing methods, HTM and HEALPix, on Solaris and Windows database servers installed with a PostgreSQL database, and a Windows Server installed with MS SQL Server. The indexing was applied to the 2MASS All-Sky Catalog and to the Hubble Source catalog. On each server, the study compared indexing performance by submitting 1 million queries at each index level with random sky positions and random cone search radius, which was computed on a logarithmic scale between 1 arcsec and 1 degree, and measuring the time to complete the query and write the output. These simulated queries, intended to model realistic use patterns, were run in a uniform way on many combinations of indexing method and indexing level. The query times in all simulations are strongly I/O-bound and are linear with number of records returned for large numbers of sources. There are, however, considerable differences between simulations, which reveal that hardware I/O throughput is a more important factor in managing the performance of a DBMS than the choice of indexing scheme. The choice of index itself is relatively unimportant: for comparable index levels, the performance is consistent within the scatter of the timings. At small index levels (large cells; e.g. level 4; cell size 3.7 deg), there is large scatter in the timings because of wide variations in the number of sources found in the cells. At larger index levels, performance improves and scatter decreases, but the improvement at level 8 (14 min) and higher is masked to some extent in the timing scatter caused by the range of query sizes. At very high levels (20; 0.0004 arsec), the granularity of the cells becomes so high that a large number of extraneous empty cells begin to degrade

  6. Spectroscopic Study of Radiation around the Leksell Gamma Knife for Room Shielding Applications

    OpenAIRE

    Hubert, Alexis

    2017-01-01

    Any center planning to install a Gamma Knife radiosurgery unit has to provide for an efficient shielding of the treatment room, to protect the patient, the staff and the public, against undesired radiation. The shielding barrier design is controlled by national and international recommendations; the reference documents for gamma ray radiotherapy facilities are the National Council on Radiation Protection and Measurements (NCRP) reports 49 and 151. However, some facts highlighted in this thesi...

  7. A Modular Pipelined Processor for High Resolution Gamma-Ray Spectroscopy

    Science.gov (United States)

    Veiga, Alejandro; Grunfeld, Christian

    2016-02-01

    The design of a digital signal processor for gamma-ray applications is presented in which a single ADC input can simultaneously provide temporal and energy characterization of gamma radiation for a wide range of applications. Applying pipelining techniques, the processor is able to manage and synchronize very large volumes of streamed real-time data. Its modular user interface provides a flexible environment for experimental design. The processor can fit in a medium-sized FPGA device operating at ADC sampling frequency, providing an efficient solution for multi-channel applications. Two experiments are presented in order to characterize its temporal and energy resolution.

  8. Study of proton beam induced gamma background in metallic backings

    CERN Document Server

    Gyuerky, G; Somorjai, E

    2003-01-01

    A low mass star burns H in the center via the pp chain. The central temperature (and the density) increases and the H-burning switches from the pp-chain to the more efficient CNO-burning. The escape of the star from the Main Sequence is powered by the onset of the CNO burning, whose bottleneck is the sup 1 sup 4 N(p,gamma) sup 1 sup 5 O reaction. Thus direct measurements of the sup 1 sup 4 N(p,gamma) sup 1 sup 5 O reaction at very low energies are needed. (R.P.)

  9. Gamma-ray measurements at the WNR white neutron source

    International Nuclear Information System (INIS)

    Nelson, R.O.; Wender, S.A.; Mayo, D.R.

    1994-01-01

    Photon production data have been acquired in the incident neutron energy range, 1 n γ 56 Fe, and 207,208 Pb. These data are useful both for testing nuclear reaction models at intermediate energies and for numerous applied purposes. BGO detectors do not have the good energy resolution of Ge detectors, but have much greater detection efficiency for gamma rays with energies greater than a few MeV. We have used an array of 5 BGO detectors to measure cross sections and angular distributions for photon production from C and N. A large, well-shielded BGO detector has been used to measure fast neutron capture in the giant resonance region with a maximum gamma-ray energy of 52 MeV. We present results of our study of the isovector giant quadrupole resonance in 41 Ca via these capture measurements. Recent measurements of inclusive photon spectra from our neutron proton Bremsstrahlung experiment have been made using a gamma-ray telescope to detect gamma-rays in the energy range, 40 γ < 300 MeV. This detector is briefly described. The advantages and disadvantages of these detector systems are discussed using examples from our measurements. The status of current measurements is presented

  10. Digested livestock wastewater treatment using gamma-ray irradiation and struvite crystallization

    International Nuclear Information System (INIS)

    Kim, Tak Hyun; Lee, Sang Ryul; Nam, Youn Ku; Lee, Myun Joo

    2009-01-01

    Livestock wastewater generally contains high strength of organics (COD), ammonia nitrogen (NH 4 + -N), phosphate phosphorus (PO 4 3- -P) and suspended solids. It is very difficult to treat by conventional wastewater treatment techniques. In this study, struvite crystallization was carried out to treat the digested livestock wastewater. 1.0 :1.2 :1.2 was determined as an optimal NH 4 + :Mg 2+ : PO 4 3- mol ratio of struvite crystallization. For the digested livestock wastewater, COD, NH 4 + -N and PO 4 3- -P removal efficiencies by struvite crystallization were 72.4%, 98.9%, and 74.8%, respectively. Gamma-ray irradiation was carried out prior to struvite crystallization of livestock wastewater. The enhancement of struvite crystallization efficiency could be obtained by the pretreatment of gamma-ray irradiation due to the decrease of COD, NH 4 + -N and PO 4 3- -P concentration

  11. A self-sufficient and general method for self-absorption correction in gamma-ray spectrometry using GEANT4

    International Nuclear Information System (INIS)

    Hurtado, S.; Villa, M.; Manjon, G.; Garcia-Tenorio, R.

    2007-01-01

    This paper presents a self-sufficient and general method for measurement of the activity of low-level gamma-emitters in voluminous samples by gamma-ray spectrometry with a coaxial germanium detector. Due to self-absorption within the sample, the full-energy peak efficiency of low-energy emitters in semiconductor gamma-spectrometers depends strongly on a number of factors including sample composition, density, sample size and gamma-ray energy. As long as those commented factors are well characterized, the influence of self-absorption in the full-energy peak efficiency of low-energy emitters can be calculated using Monte Carlo method based on GEANT4 code for each individual sample. However this task is quite tedious and time consuming. In this paper, we propose an alternative method to determine this influence for voluminous samples of unknown composition. Our method combines both transmission measurements and Monte Carlo simulations, avoiding the application of Monte Carlo full-energy peak efficiency determinations for each individual sample. To test the accuracy and precision of the proposed method, we have calculated 210 Pb activity in sediments samples from an estuary located in the vicinity of several phosphates factories with the proposed method, comparing the obtained results with the ones determined in the same samples using two alternative radiometric techniques

  12. In situ measurements of dose rates from terrestrial gamma rays

    International Nuclear Information System (INIS)

    Horng, M.C.; Jiang, S.H.

    2002-01-01

    A portable, high purity germanium (HPGe) detector was employed for the performance of in situ measurements of radionuclide activity concentrations in the ground in Taiwan, at altitudes ranging from sea level to 3900 m. The absolute peak efficiency of the HPGe detector for a gamma-ray source uniformly distributed in the semi-infinite ground was determined using a semi-empirical method. The gamma-ray dose rates from terrestrial radionuclides were calculated from the measured activity levels using recently published dose rate conversion factors. The absorbed dose rate in air due to cosmic rays was derived by subtracting the terrestrial gamma-ray dose rate from the overall absorbed dose rate in air measured using a high-pressure ionization chamber. The cosmic-ray dose rate calculated as a function of altitude, was found to be in good agreement with the data reported by UNSCEAR. (orig.)

  13. Principle of some gamma cameras (efficiencies, limitations, development)

    International Nuclear Information System (INIS)

    Allemand, R.; Bourdel, J.; Gariod, R.; Laval, M.; Levy, G.; Thomas, G.

    1975-01-01

    The quality of scintigraphic images is shown to depend on the efficiency of both the input collimator and the detector. Methods are described by which the quality of these images may be improved by adaptations to either the collimator (Fresnel zone camera, Compton effect camera) or the detector (Anger camera, image amplification camera). The Anger camera and image amplification camera are at present the two main instruments whereby acceptable space and energy resolutions may be obtained. A theoretical comparative study of their efficiencies is carried out, independently of their technological differences, after which the instruments designed or under study at the LETI are presented: these include the image amplification camera, the electron amplifier tube camera using a semi-conductor target CdTe and HgI 2 detector [fr

  14. PPAR gamma Pro(12)Ala polymorphism and risk of acute coronary syndrome in a prospective study of Danes

    DEFF Research Database (Denmark)

    Vogel, Ulla Birgitte; Segel, Stine; Dethlefsen, Claus

    2009-01-01

    Background: Acute coronary syndrome (ACS) is a major cause of morbidity and mortality in the western world. Peroxisome proliferator-activated receptor gamma (PPAR gamma) plays a key role in the regulation of the energy balance, adipocyte differentiation and lipid biosynthesis. The aim...... was to investigate if the polymorphism PPAR gamma 2 Pro(12)Ala, which encodes a less efficient transcription factor, was associated with risk of acute coronary disease and if there were interactions between this polymorphism and factors that modify PPAR gamma activity, such as alcohol intake, smoking, and use of non...

  15. Development of amphiphilic gamma-PGA-nanoparticle based tumor vaccine: potential of the nanoparticulate cytosolic protein delivery carrier.

    Science.gov (United States)

    Yoshikawa, Tomoaki; Okada, Naoki; Oda, Atsushi; Matsuo, Kazuhiko; Matsuo, Keisuke; Mukai, Yohei; Yoshioka, Yasuo; Akagi, Takami; Akashi, Mitsuru; Nakagawa, Shinsaku

    2008-02-08

    Nanoscopic therapeutic systems that incorporate biomacromolecules, such as protein and peptides, are emerging as the next generation of nanomedicine aimed at improving the therapeutic efficacy of biomacromolecular drugs. In this study, we report that poly(gamma-glutamic acid)-based nanoparticles (gamma-PGA NPs) are excellent protein delivery carriers for tumor vaccines that delivered antigenic proteins to antigen-presenting cells and elicited potent immune responses. Importantly, gamma-PGA NPs efficiently delivered entrapped antigenic proteins through cytosolic translocation from the endosomes, which is a key process of gamma-PGA NP-mediated anti-tumor immune responses. Our findings suggest that the gamma-PGA NP system is suitable for the intracellular delivery of protein-based drugs as well as tumor vaccines.

  16. Empirical Examination of Fundamental Indexation in the German Market

    Science.gov (United States)

    Mihm, Max; Locarek-Junge, Hermann

    Index Funds, Exchange Traded Funds and Derivatives give investors easy access to well diversified index portfolios. These index-based investment products exhibit low fees, which make them an attractive alternative to actively managed funds. Against this background, a new class of stock indices has been established based on the concept of “Fundamental Indexation”. The selection and weighting of index constituents is conducted by means of fundamental criteria like total assets, book value or number of employees. This paper examines the performance of fundamental indices in the German equity market. For this purpose, a backtest of five fundamental indices is conducted over the last 20 years. Furthermore the index returns are analysed under the assumption of an efficient as well as an inefficient market. Index returns in efficient markets are explained by applying the three factor model for stock returns of Fama and French (J Financ Econ 33(1):3-56, 1993). The results show that the outperformance of fundamental indices is partly due to a higher risk exposure, particularly to companies with a low price to book ratio. By relaxing the assumption of market efficiency, a return drag of capitalisation weighted indices can be deduced. Given a mean-reverting movement of prices, a direct connection between market capitalisation and index weighting leads to inferior returns.

  17. Can Winds Driven by Active Galactic Nuclei Account for the Extragalactic Gamma-Ray and Neutrino Backgrounds?

    Science.gov (United States)

    Liu, Ruo-Yu; Murase, Kohta; Inoue, Susumu; Ge, Chong; Wang, Xiang-Yu

    2018-05-01

    Various observations are revealing the widespread occurrence of fast and powerful winds in active galactic nuclei (AGNs) that are distinct from relativistic jets, likely launched from accretion disks and interacting strongly with the gas of their host galaxies. During the interaction, strong shocks are expected to form that can accelerate nonthermal particles to high energies. Such winds have been suggested to be responsible for a large fraction of the observed extragalactic gamma-ray background (EGB) and the diffuse neutrino background, via the decay of neutral and charged pions generated in inelastic pp collisions between protons accelerated by the forward shock and the ambient gas. However, previous studies did not properly account for processes such as adiabatic losses that may reduce the gamma-ray and neutrino fluxes significantly. We evaluate the production of gamma rays and neutrinos by AGN-driven winds in detail by modeling their hydrodynamic and thermal evolution, including the effects of their two-temperature structure. We find that they can only account for less than ∼30% of the EGB flux, as otherwise the model would violate the independent upper limit derived from the diffuse isotropic gamma-ray background. If the neutrino spectral index is steep with Γ ≳ 2.2, a severe tension with the isotropic gamma-ray background would arise as long as the winds contribute more than 20% of the IceCube neutrino flux in the 10–100 TeV range. At energies ≳ 100 TeV, we find that the IceCube neutrino flux may still be accountable by AGN-driven winds if the spectral index is as small as Γ ∼ 2.0–2.1.

  18. Efficiency of S&P CNX Nifty Index Option of the National Stock Exchange (NSE, India, using Box Spread Arbitrage Strategy

    Directory of Open Access Journals (Sweden)

    G. P. Girish

    2014-09-01

    Full Text Available Box spread is a trading strategy in which one simultaneously buys and sells options having the same underlying asset and time to expiration, but different exercise prices. This study examined the efficiency of European style S&P CNX Nifty Index options of National Stock Exchange, (NSE India by making use of high-frequency data on put and call options written on Nifty (Time-stamped transactions data for the time period between 1st January 2002 and 31st December 2005 using box-spread arbitrage strategy. The advantages of box-spreads include reduced joint hypothesis problem since there is no consideration of pricing model or market equilibrium, no consideration of inter-market non-synchronicity since trading box spreads involve only one market, computational simplicity with less chances of mis-specification error, estimation error and the fact that buying and selling box spreads more or less replicates risk-free lending and borrowing. One thousand three hundreds and fifty eight exercisable box-spreads were found for the time period considered of which 78 Box spreads were found to be profitable after incorporating transaction costs (32 profitable box spreads were identified for the year 2002, 19 in 2003, 14 in 2004 and 13 in 2005 The results of our study suggest that internal option market efficiency has improved over the years for S&P CNX Nifty Index options of NSE India.

  19. Dose profile monitoring with carbon ions by means of prompt-gamma measurements

    Energy Technology Data Exchange (ETDEWEB)

    Testa, E. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France)], E-mail: e.testa@ipnl.in2p3.fr; Bajard, M.; Chevallier, M.; Dauvergne, D.; Le Foulher, F. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France); Freud, N.; Letang, J.M. [Institut National des Sciences Appliquees de Lyon, Laboratoire de Controle Non-Destructif par Rayonnements Ionisants (France); Poizat, J.C.; Ray, C.; Testa, M. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France)

    2009-03-15

    A key point in the quality control of ion therapy is real-time monitoring and imaging of the dose delivered to the patient. Among the possible signals that can be used to make such a monitoring, prompt gamma-rays issued from nuclear fragmentation are possible candidates, provided the correlation between the emission profile and the primary beam range can be established. By means of simultaneous energy and time-of-flight discrimination, we could measure the longitudinal profile of the prompt gamma-rays emitted by 73 MeV/u carbon ions stopping inside a PMMA target. This technique allowed us to minimize the shielding against neutrons and scattered gamma rays, and to find a good correlation between the prompt-gamma profile and the ion range. This profile was studied as a function of the observation angle. By extrapolating our results to higher energies and realistic detection efficiencies, we showed that prompt gamma-ray measurements make it feasible to control in real time the longitudinal dose during ion therapy treatments.

  20. Effect of body mass index on serum leptin levels

    International Nuclear Information System (INIS)

    Paul, R.F.; Hassan, M.; Nazar, H.S.

    2012-01-01

    Background: Leptin is product of ob gene, an adipose tissue derived hormone that plays a key role in the regulation of body fat mass by regulating appetite and metabolism while balancing energy intake and energy expenditure. The objective of the study was to evaluate possible association between serum leptin levels and Body Mass Index (BMI) of gender in adult age group. Methods: Two-hundred-seventy subjects aged 20-50 years were randomly selected from general population of Abbottabad. The subjects were grouped on the basis on BMI (89 normal, 92 overweight, and 89 obese). After complete evaluation, demographic data was recorded and BMI. Non-fasting venous blood samples were drawn to measure serum leptin and serum glucose levels. The data were analysed using SPSS-15 calculating mean, percentage, independent t-test and chi-square test. Correlation and regression curve analysis were obtained, and p and r values were calculated. Results: Serum leptin levels and differences between genders were significant in all body mass indices. For normal BMI group the mean values for leptin were 2.6+-1.5 gamma g/ml in men, and 17.3+9-10.2 gamma g/ml for women. For Group-2 mean leptin levels in men were 9.9+-6.8 gamma g/ml and in women were 34.8+-13.6 gamma g/ml. For Group-3 BMI comprising obese subjects mean values for men were 21.3+-14.2 gamma g/ml and for women were 48.21+-21.2 gamma g/ml (p<0.001). Conclusion: A progressive increase in serum leptin concentration was observed with an increase in BMI. Significant difference between leptin concentrations in either gender was found in normal, overweight and obese subjects. (author)

  1. Total-factor energy efficiency of regions in China

    International Nuclear Information System (INIS)

    Hu, J.-L.; Wang, S.-C.

    2006-01-01

    This paper analyzes energy efficiencies of 29 administrative regions in China for the period 1995-2002 with a newly introduced index. Most existing studies of regional productivity and efficiency neglect energy inputs. We use the data envelopment analysis (DEA) to find the target energy input of each region in China at each particular year. The index of total-factor energy efficiency (TFEE) then divides the target energy input by the actual energy input. In our DEA model, labor, capital stock, energy consumption, and total sown area of farm crops used as a proxy of biomass energy are the four inputs and real GDP is the single output. The conventional energy productivity ratio regarded as a partial-factor energy efficiency index is computed for comparison in contrast to TFEE; our index is found fitting better to the real case. According to the TFEE index rankings, the central area of China has the worst energy efficiency and its total adjustmentof energy consumption amount is over half of China's total. Regional TFEE in China generally improved during the research period except for the western area. A U-shape relation between the area's TFEE and per capita income in the areas of China is found, confirming the scenario that energy efficiency eventually improves with economic growth

  2. Lead foil wrapping of the plastic scintillators for the gamma ray detection: optical reflector or spectrum intensifier?

    International Nuclear Information System (INIS)

    Taheri, A.; Askari, M.; Sasanpour, M. Taghan

    2017-01-01

    This paper studies the effect of lead wrapping on the response of the plastic scintillators as gamma detectors. Experimental tests and Geant4 simulations showed that lead wrapping cannot increase the gamma absorption efficiency of the detector but, as a reflector, it can improve the optical properties of the detector. The reflectivity of the lead foil as an optical reflector was determined equal to 66% using an experimental-simulation combined method. Based on the obtained results, the optical collection efficiency of the detector was also increased about 4% after employing the lead reflector.

  3. Modulation of Enzymatic Activities of Dual Functional Peroxiredoxin by Gamma Irradiation

    International Nuclear Information System (INIS)

    Hong, Sung Hyun; Lee, Seung Sik; Park, Chul Hong; Chung, Byung Yeoup

    2012-01-01

    Recently, enzymes have frequently been used as catalysts in various bio-industrial, commercial, and pharmaceutical applications, because they are more stable, more efficient, and less toxic than the synthetic catalysts. However, one of their major disadvantages is their low thermostability, which leads the researchers to develop new forms of industrially important enzymes with increased resistance to inactivation and aggregation. This study describes a strategy for modifying the molecular chaperone activity of peroxiredoxin (Prx) by using gamma irradiation. Prxs are a ubiquitous family of antioxidant enzymes. Upon oxidation of their peroxidatic Cys, the molecules undergo a structural conversion from a low-molecular-weight (LMW) species acting as a peroxidase to a high-molecular-weight (HMW) complex functioning as a chaperone. In the present study, we examined the effect of gamma irradiation on PP1084 with respect to its protein structure and enzymatic function. The use of gamma irradiation as a physical treatment can increase the cohesive strength of the protein by forming cross-links. The aims of the present work were (1) to improve the chaperone activity of PP1084 by gamma irradiation, (2) to identify the 'optimal' intensity of gamma irradiation, and (3) to investigate the influence of gamma irradiation on protein hydrophobicity as related to chaperone function. Following PP1084 treatment with 30 kGy gamma irradiation, the PP1084 chaperone activity enhanced by about 3-4-fold compared with nonirradiated PP1084, while the peroxidase activity decreased. Ongoing research efforts are addressing the physical modifications of PP1084 protein by gamma irradiation

  4. ATLAS searches for VH, HH, VV, V+$\\gamma$/$\\gamma\\gamma$ resonances

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00441490; The ATLAS collaboration

    2017-01-01

    The discovery of a Higgs boson at the Large Hadron Collider motivates searches for physics beyond the Standard Model in channels involving coupling to the Higgs boson. A search for massive resonances decaying into couples of bosons is described. The considered final states are: $HH$, $VH$, $VV$, $V\\gamma$ and $\\gamma\\gamma$ with $V$ indicating either the $W$ or the $Z$ boson. Final states with different number of leptons or photons and where, in many cases, at least one Higgs decays into a b-quark pair are studied using different jet reconstruction techniques which allow to optimize the signal acceptance for low or high Higgs boson transverse momentum. The most recent diboson resonance searches using LHC Run 2 data are described.

  5. Method of incident low-energy gamma-ray direction reconstruction in the GAMMA-400 gamma-ray space telescope

    International Nuclear Information System (INIS)

    Kheymits, M D; Leonov, A A; Zverev, V G; Galper, A M; Arkhangelskaya, I V; Arkhangelskiy, A I; Yurkin, Yu T; Bakaldin, A V; Suchkov, S I; Topchiev, N P; Dalkarov, O D

    2016-01-01

    The GAMMA-400 gamma-ray space-based telescope has as its main goals to measure cosmic γ-ray fluxes and the electron-positron cosmic-ray component produced, theoretically, in dark-matter-particles decay or annihilation processes, to search for discrete γ-ray sources and study them in detail, to examine the energy spectra of diffuse γ-rays — both galactic and extragalactic — and to study gamma-ray bursts (GRBs) and γ-rays from the active Sun. Scientific goals of GAMMA-400 telescope require fine angular resolution. The telescope is of a pair-production type. In the converter-tracker, the incident gamma-ray photon converts into electron-positron pair in the tungsten layer and then the tracks are detected by silicon- strip position-sensitive detectors. Multiple scattering processes become a significant obstacle in the incident-gamma direction reconstruction for energies below several gigaelectronvolts. The method of utilising this process to improve the resolution is proposed in the presented work. (paper)

  6. Deterministic indexing for packed strings

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Skjoldjensen, Frederik Rye

    2017-01-01

    Given a string S of length n, the classic string indexing problem is to preprocess S into a compact data structure that supports efficient subsequent pattern queries. In the deterministic variant the goal is to solve the string indexing problem without any randomization (at preprocessing time...... or query time). In the packed variant the strings are stored with several character in a single word, giving us the opportunity to read multiple characters simultaneously. Our main result is a new string index in the deterministic and packed setting. Given a packed string S of length n over an alphabet σ...

  7. Gamma-ray identification of nuclear weapon materials

    International Nuclear Information System (INIS)

    Gosnell, T. B.; Hall, J. M.; Jam, C. L.; Knapp, D. A.; Koenig, Z. M.; Luke, S. J.; Pohl, B. A.; Schach Wittenau, A. von; Wolford, J. K.

    1997-01-01

    There has been an accelerating national interest in countering nuclear smuggling. This has caused a corresponding expansion of interest in the use of gamma-ray spectrometers for checkpoint monitoring, nuclear search, and within networks of nuclear and collateral sensors. All of these are fieldable instruments--ranging from large, fixed portal monitors to hand-held and remote monitoring equipment. For operational reasons, detectors with widely varying energy resolution and detection efficiency will be employed. In many instances, such instruments must be sensitive to weak signals, always capable of recognizing the gamma-ray signatures from nuclear weapons materials (NWM), often largely insensitive to spectral alteration by radiation transport through intervening materials, capable of real-time implementation, and able to discriminate against signals from commonly encountered legitimate gamma-ray sources, such as radiopharmaceuticals. Several decades of experience in classified programs have shown that all of these properties are not easily achieved and successful approaches were of limited scope--such as the detection of plutonium only. This project was originally planned as a two-year LDRD-ER. Since funding for 1997 was not sustained, this is a report of the first year's progress

  8. Study on 3D gamma-ray imaging for medical diagnosis with coded aperture

    International Nuclear Information System (INIS)

    Horiki, Kazunari; Shimazoe, Kenji; Ohno, Masashi; Takahashi, Hiroyuki; Kobashi, Keiji; Moro, Eiji

    2014-01-01

    The conventional methods for medical imaging have several disadvantages such as restriction on the energy and detection efficiency. Coded aperture imaging can be used for medical imagings without restriction on the energy, which makes it possible to use multiple tracers in diagnosis. The detection efficiency of Coded aperture imaging is ten times better than that of the pinhole collimator. First, simulations of the coded aperture imaging have been done to confirm M-array's effectiveness. Second, two experiments have been done with low-energy gamma-ray (122 keV( 57 Co)) and with high-energy gamma-ray (662 keV( 137 Cs)). In both cases reconstructed image was successfully acquired. The measured spatial resolution in the experiment using 57 Co is 4.3 mm (FWHM). (author)

  9. Observations of the highest energy gamma-rays from gamma-ray bursts

    International Nuclear Information System (INIS)

    Dingus, Brenda L.

    2001-01-01

    EGRET has extended the highest energy observations of gamma-ray bursts to GeV gamma rays. Such high energies imply the fireball that is radiating the gamma-rays has a bulk Lorentz factor of several hundred. However, EGRET only detected a few gamma-ray bursts. GLAST will likely detect several hundred bursts and may extend the maximum energy to a few 100 GeV. Meanwhile new ground based detectors with sensitivity to gamma-ray bursts are beginning operation, and one recently reported evidence for TeV emission from a burst

  10. Crystal diffraction lens telescope for focusing nuclear gamma rays

    International Nuclear Information System (INIS)

    Smither, R.K.; Fernandez, P.B.; Graber, T.; Faiz, M.

    1996-08-01

    A crystal diffraction lens was constructed at Argonne National Laboratory for use as a telescope to focus nuclear gamma rays. It consisted of 600 single crystals of germanium arranged in 8 concentric rings. The mounted angle of each crystal was adjusted to intercept and diffract the incoming gamma rays with an accuracy of a few arc sec. The performance of the lens was tested in two ways. In one case, the gamma rays were focused on a single medium size germanium detector. In the second case, the gamma rays were focused on the central germanium detector of a 3 x 3 matrix of small germanium detectors. The efficiency, image concentration and image quality, and shape were measured. The tests performed with the 3 x 3 matrix detector system were particularly interesting. The wanted radiation was concentrated in the central detector. The 8 other detectors were used to detect the Compton scattered radiation, and their energy was summed with coincident events in the central detector. This resulted in a detector with the efficiency of a large detector (all 9 elements) and the background of a small detector (only the central element). The use of the 3 x 3 detector matrix makes it possible to tell if the source is off axis and, if so, to tell in which direction. The crystal lens acts very much like a simple convex lens for visible light. Thus if the source is off to the left then the image will focus off to the right illuminating the detector on the right side: telling one in which direction to point the telescope. Possible applications of this type of crystal lens to balloon and satellite experiments will be discussed

  11. Uteroplacental blood flow in diabetic pregnancy: measurements with indium 113m and a computer-linked gamma camera

    International Nuclear Information System (INIS)

    Nylund, L.; Lunell, N.O.; Lewander, R.; Persson, B.; Sarby, B.

    1982-01-01

    The uteroplacental blood flow index in the last trimester of pregnancy in 26 women with diabetes mellitus was compared to that in 41 healthy control subjects. After an intravenous injection of 1 mCi of indium 113m, the radiation over the placenta was recorded with a computer-linked gamma camera. From time-activity analysis of the isotope accumulation curve, a uteroplacental blood flow index could be calculated. In the diabetic pregnant women, the maternal-placental blood flow index was reduced 35% to 45% compared to that in healthy women. The blood flow index tended to be further impaired in those diabetic women who had higher blood glucose values

  12. GAMMA-RAY OBSERVATIONS OF THE SUPERNOVA REMNANT RX J0852.0-4622 WITH THE FERMI LARGE AREA TELESCOPE

    International Nuclear Information System (INIS)

    Tanaka, T.; Allafort, A.; Funk, S.; Tajima, H.; Uchiyama, Y.; Ballet, J.; Giordano, F.; Hewitt, J.; Lemoine-Goumard, M.; Tibolla, O.

    2011-01-01

    We report on gamma-ray observations of the supernova remnant (SNR) RX J0852.0-4622 with the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope. In the Fermi-LAT data, we find a spatially extended source at the location of the SNR. The extension is consistent with the SNR size seen in other wavelengths such as X-rays and TeV gamma rays, leading to the identification of the gamma-ray source with the SNR. The spectrum is well described as a power law with a photon index of Γ = 1.85 ± 0.06 (stat) +0.18 -0.19 (sys), which smoothly connects to the H.E.S.S. spectrum in the TeV energy band. We discuss the gamma-ray emission mechanism based on multiwavelength data. The broadband data can be fit well by a model in which the gamma rays are of hadronic origin. We also consider a scenario with inverse Compton scattering of electrons as the emission mechanism of the gamma rays. Although the leptonic model predicts a harder spectrum in the Fermi-LAT energy range, the model can fit the data considering the statistical and systematic errors.

  13. The diet-related GHG index

    DEFF Research Database (Denmark)

    Lund, Thomas Bøker; Watson, David; Smed, Sinne

    2017-01-01

    The aim was to construct and validate a cost-efficient index to measure GHG emissions (GHGe) caused by Danish consumers’ diets to be employed in questionnaire-based surveys. The index was modelled on the basis of actual food purchase data from a panel of ordinary Danish households...... and a questionnaire consisting of food frequency questions issued to the same panel. Based on the purchase data, diet-related GHGe were calculated for 2012. The data was then split into a learning sample and a validation sample. The index was constructed using the learning sample where a scoring procedure...... was calculated from responses to the questionnaire-based food frequency questions that predicted diet-related GHGe. Subsequently, the index scoring procedure was employed on the validation sample and the empirical relevance of the index was examined. In the learning sample, a scoring procedure to construct...

  14. Radiation hardness of GaAs sensors against gamma-rays, neutrons and electrons

    Energy Technology Data Exchange (ETDEWEB)

    Šagátová, Andrea, E-mail: andrea.sagatova@stuba.sk [Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 812 19 Bratislava (Slovakia); University Centre of Electron Accelerators, Slovak Medical University, Ku kyselke 497, 911 06 Trenčín (Slovakia); Zaťko, Bohumír; Dubecký, František [Institute of Electrical Engineering, Slovak Academy of Sciences, Dúbravská cesta 9, 841 04 Bratislava (Slovakia); Ly Anh, Tu [Faculty of Applied Science, University of Technology VNU HCM, 268 Ly Thuong Kiet Street, District 10, Ho Chi Minh City (Viet Nam); Nečas, Vladimír; Sedlačková, Katarína; Pavlovič, Márius [Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 812 19 Bratislava (Slovakia); Fülöp, Marko [University Centre of Electron Accelerators, Slovak Medical University, Ku kyselke 497, 911 06 Trenčín (Slovakia)

    2017-02-15

    Highlights: • Radiation hardness of SI GaAs detectors against gamma-rays, neutrons and electrons was compared. • Good agreement was achieved between the experimental results and displacement damage factor of different types of radiation. • CCE and FWHM first slightly improved (by 1–8%) and just then degraded with the cumulative dose. • An increase of detection efficiency with cumulative dose was observed. - Abstract: Radiation hardness of semi-insulating GaAs detectors against {sup 60}Co gamma-rays, fast neutrons and 5 MeV electrons was compared. Slight improvements in charge collection efficiency (CCE) and energy resolution in FWHM (Full Width at Half Maximum) were observed at low doses with all kinds of radiation followed by their degradation. The effect occurred at a dose of about 10 Gy of neutrons (CCE improved by 1%, FWHM by 5% on average), at 1 kGy of electrons (FWHM decreased by 3% on average) and at 10 kGy of gamma-rays (CCE raised by 5% and FWHM dropped by 8% on average), which is in agreement with the relative displacement damage of the used types of radiation. Gamma-rays of MeV energies are 1000-times less damaging than similar neutrons and electrons about 10-times more damaging than photons. On irradiating the detectors with neutrons and electrons, we observed a global increase in their detection efficiency, which was caused probably by enlargement of the active detector area as a consequence of created radiation defects in the base material. Detectors were still functional after a dose of 1140 kGy of ∼1 MeV photons, 104 kGy of 5 MeV electrons but only up to 0.576 kGy of fast (∼2 to 30 MeV) neutrons.

  15. Analysis of 137Cs radionuclides activities in Cs-zeolite using gamma spectrometry

    International Nuclear Information System (INIS)

    Noviarty; Ginting, Aslina Br; Anggraini, Dian; Rosika K

    2013-01-01

    137 Cs Radionuclide activity analysis has been carried out. The objective is to determine the activity of the 137 Cs radionuclide in Cs-zeolite are packaged in the form of point source. Analysis of 137 Cs Radionuclide activities in Cs zeolite samples was determined by measuring intensity of the isotope 137 Cs gamma energy at 661.7 keV use-y spectrometer. Before measurement the sample, was first carried out measurements of 137 Cs radionuclide in certified point standards from Amersham, to determine the efficiency value. Result the standard sample measurement obtained the efficiency value of 43.98%. Efficiency values obtained are used in the calculation of sample activity. On the measurement of the intensity of the sample obtained results dose rate 196.4537 cps with a standard deviation of 0.5274. By using standard measurement efficiency values obtained by the calculation of the average activity of the radionuclide 137 Cs in Cs-zeolite 524.9082 Bq. Deviation measurements were below 5% (0.27% ) so that the analysis of the activity of radionuclide 137 Cs in Cs-zeolite samples using gamma spectrometer can be accepted with a 95% confidence level. (author)

  16. Gamma radiolysis of alachlor aqueous solutions in the presence of hydrogen peroxide

    International Nuclear Information System (INIS)

    Choi, Dongkyu; Lee, O-Mi; Yu, Seungho; Jeong, Seung-Woo

    2010-01-01

    The enhanced effect of gamma irradiation with hydrogen peroxide (H 2 O 2 ) for alachlor degradation in an aqueous solution was first investigated in this study. The combination of gamma irradiation and H 2 O 2 led to an enhanced effect, which remarkably increased the degradation efficiency of alachlor and the total organic carbon (TOC) removal. At a dose of 200 Gy, the degradation degree of the alachlor solution reached 81.7 and 99.2% under H 2 O 2 concentrations of 0 and 0.1 μM, respectively. In addition, the TOC removal efficiencies of the alachlor under initial H 2 O 2 concentrations of 0, 0.5 and 1.0 μM were 59.5, 74.8 and 83.8%, respectively, at an absorbed dose of 20 kGy. However, for higher H 2 O 2 concentrations (greater than 1 μM), the alachlor degradation was reduced because ·OH radicals were scavenged by the H 2 O 2 . The biodegradability of alachlor solutions prior to and after treatment by gamma irradiation was also assessed using the Closed Bottle Test (CBT). The results showed enhanced biodegradability of alachlor with increasing absorbed doses.

  17. Levelling Airborne and Ground Gamma-Ray Spectrometric Data to Assist Uranium Exploration

    Energy Technology Data Exchange (ETDEWEB)

    Matolin, M., E-mail: matolin@natur.cuni.cz [Charles University, Prague (Czech Republic); Minty, B. [Geoscience Australia, Canberra (Australia)

    2014-05-15

    Geophysical methods can be used for mapping in both 2 and 3 dimensions, as well as the direct detection of ore bodies. The gamma-ray spectrometric method is an efficient method for the regional assessment of uranium potential and the detection of surface mineralization. However, the full potential of the method can only be realized when the data are adequately standardized. Examples of this standardization at both regional and local scales are dealt in this paper. At a regional scale, it is shown how the levelling of airborne gamma-ray spectrometry data over Australia increases the value of the resulting data, and on a local scale a geometrical correction for ground gamma-ray spectrometry in shallow holes that improves the accuracy of measurements is introduced. (author)

  18. The evaluation model of the enterprise energy efficiency based on DPSR.

    Science.gov (United States)

    Wei, Jin-Yu; Zhao, Xiao-Yu; Sun, Xue-Shan

    2017-05-08

    The reasonable evaluation of the enterprise energy efficiency is an important work in order to reduce the energy consumption. In this paper, an effective energy efficiency evaluation index system is proposed based on DPSR (Driving forces-Pressure-State-Response) with the consideration of the actual situation of enterprises. This index system which covers multi-dimensional indexes of the enterprise energy efficiency can reveal the complete causal chain which includes the "driver forces" and "pressure" of the enterprise energy efficiency "state" caused by the internal and external environment, and the ultimate enterprise energy-saving "response" measures. Furthermore, the ANP (Analytic Network Process) and cloud model are used to calculate the weight of each index and evaluate the energy efficiency level. The analysis of BL Company verifies the feasibility of this index system and also provides an effective way to improve the energy efficiency at last.

  19. Assessment of measurement result uncertainty in determination of 210Pb with the focus on matrix composition effect in gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Iurian, A.R.; Pitois, A.; Kis-Benedek, G.; Migliori, A.; Padilla-Alvarez, R.; Ceccatelli, A.

    2016-01-01

    Reference materials were used to assess measurement result uncertainty in determination of 210 Pb by gamma-ray spectrometry, liquid scintillation counting, or indirectly by alpha-particle spectrometry, using its daughter 210 Po in radioactive equilibrium. Combined standard uncertainties of 210 Pb massic activities obtained by liquid scintillation counting are in the range 2–12%, depending on matrices and massic activity values. They are in the range 1–3% for the measurement of its daughter 210 Po using alpha-particle spectrometry. Three approaches (direct computation of counting efficiency and efficiency transfer approaches based on the computation and, respectively, experimental determination of the efficiency transfer factors) were applied for the evaluation of 210 Pb using gamma-ray spectrometry. Combined standard uncertainties of gamma-ray spectrometry results were found in the range 2–17%. The effect of matrix composition on self-attenuation was investigated and a detailed assessment of uncertainty components was performed. - Highlights: • Confirmed 210 Pb certified values by LSC and alpha-particle spectrometry ( 210 Po). • Assessed 210 Po measurement result uncertainty by alpha-particle spectrometry. • Matrix composition effect on gamma-ray spectrometry measurement result uncertainty. • Assessment of 210 Pb measurement result uncertainty by gamma-ray spectrometry. • Comparison of techniques and approaches: ‘fit-for-purpose’ considerations.

  20. {sup 134}Cs emission probabilities determination by gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: candida@cnen.gov.br [Comissão Nacional de Energia Nuclear (DINOR/CNEN), Riode Janeiro, RJ (Brazil); Poledna, R.; Delgado, J.U.; Silva, R.L.; Araujo, M.T.; Silva, C.J. da [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed primary and secondary standardization of different radionuclides reaching satisfactory uncertainties. A solution of {sup 134}Cs radionuclide was purchased from commercial supplier to emission probabilities determination of some of its energies. {sup 134}Cs is a beta gamma emitter with 754 days of half-life. This radionuclide is used as standard in environmental, water and food control. It is also important to germanium detector calibration.The gamma emission probabilities (Pγ) were determined mainly for some energies of the {sup 134}Cs by efficiency curve method and the Pγ absolute uncertainties obtained were below 1% (k=1). (author)