WorldWideScience

Sample records for efficient gamma index

  1. Efficient gamma index calculation using fast Euclidean distance transform

    Energy Technology Data Exchange (ETDEWEB)

    Chen Mingli; Lu Weiguo; Chen Quan; Ruchala, Kenneth; Olivera, Gustavo [TomoTherapy Inc., 1240 Deming Way, Madison, WI 53717 (United States)], E-mail: wlu@tomotherapy.com

    2009-04-07

    The gamma index is a tool for dose distribution comparison. It combines both dose difference (DD) and distance to agreement (DTA) into a single quantity. Though it is an effective measure, making up for the inadequacy of DD or DTA alone, its calculation can be very time-consuming. For a k-D space with N quantization levels in each dimension, the complexity of the exhaustive search is O(N{sup 2k}). In this work, we proposed an efficient method that reduces the complexity from O(N{sup 2k}) to O(N{sup k}M), where M is the number of discretized dose values and is comparable to N. More precisely, by embedding the reference dose distribution in a (k+1)-D spatial-dose space, we can use fast Euclidean distance transform with linear complexity to obtain a table of gamma indices evaluated over a range of the (k+1)-D spatial-dose space. Then, to obtain gamma indices for the test dose distribution, it requires only table lookup with complexity O(N{sup k}). Such a table can also be used for other test dose distributions as long as the reference dose distribution is the same. Simulations demonstrated the efficiency of our proposed method. The speedup for 3D gamma index calculation is expected to be on the order of tens of thousands (from O(N{sup 6}) to O(N{sup 3}M)) if N is a few hundreds, which makes clinical usage of the 3D gamma index feasible. A byproduct of the gamma index table is that the gradient of the gamma index with respect to either the spatial or dose dimension can be easily derived. The gradient can be used to identify the main causes of the discrepancy from the reference distribution at any dose point in the test distribution or incorporated in treatment planning and machine parameter optimization.

  2. Derivative based sensitivity analysis of gamma index

    Directory of Open Access Journals (Sweden)

    Biplab Sarkar

    2015-01-01

    Full Text Available Originally developed as a tool for patient-specific quality assurance in advanced treatment delivery methods to compare between measured and calculated dose distributions, the gamma index (γ concept was later extended to compare between any two dose distributions. It takes into effect both the dose difference (DD and distance-to-agreement (DTA measurements in the comparison. Its strength lies in its capability to give a quantitative value for the analysis, unlike other methods. For every point on the reference curve, if there is at least one point in the evaluated curve that satisfies the pass criteria (e.g., δDD = 1%, δDTA = 1 mm, the point is included in the quantitative score as "pass." Gamma analysis does not account for the gradient of the evaluated curve - it looks at only the minimum gamma value, and if it is <1, then the point passes, no matter what the gradient of evaluated curve is. In this work, an attempt has been made to present a derivative-based method for the identification of dose gradient. A mathematically derived reference profile (RP representing the penumbral region of 6 MV 10 cm × 10 cm field was generated from an error function. A general test profile (GTP was created from this RP by introducing 1 mm distance error and 1% dose error at each point. This was considered as the first of the two evaluated curves. By its nature, this curve is a smooth curve and would satisfy the pass criteria for all points in it. The second evaluated profile was generated as a sawtooth test profile (STTP which again would satisfy the pass criteria for every point on the RP. However, being a sawtooth curve, it is not a smooth one and would be obviously poor when compared with the smooth profile. Considering the smooth GTP as an acceptable profile when it passed the gamma pass criteria (1% DD and 1 mm DTA against the RP, the first and second order derivatives of the DDs (δD', δD" between these two curves were derived and used as the

  3. Impact of image noise on gamma index calculation

    International Nuclear Information System (INIS)

    Chen, M; Mo, X; Parnell, D; Olivera, G; Galmarini, D; Lu, W

    2014-01-01

    Purpose: The Gamma Index defines an asymmetric metric between the evaluated image and the reference image. It provides a quantitative comparison that can be used to indicate sample-wised pass/fail on the agreement of the two images. The Gamma passing/failing rate has become an important clinical evaluation tool. However, the presence of noise in the evaluated and/or reference images may change the Gamma Index, hence the passing/failing rate, and further, clinical decisions. In this work, we systematically studied the impact of the image noise on the Gamma Index calculation. Methods: We used both analytic formulation and numerical calculations in our study. The numerical calculations included simulations and clinical images. Three different noise scenarios were studied in simulations: noise in reference images only, in evaluated images only, and in both. Both white and spatially correlated noises of various magnitudes were simulated. For clinical images of various noise levels, the Gamma Index of measurement against calculation, calculation against measurement, and measurement against measurement, were evaluated. Results: Numerical calculations for both the simulation and clinical data agreed with the analytic formulations, and the clinical data agreed with the simulations. For the Gamma Index of measurement against calculation, its distribution has an increased mean and an increased standard deviation as the noise increases. On the contrary, for the Gamma index of calculation against measurement, its distribution has a decreased mean and stabilized standard deviation as the noise increases. White noise has greater impact on the Gamma Index than spatially correlated noise. Conclusions: The noise has significant impact on the Gamma Index calculation and the impact is asymmetric. The Gamma Index should be reported along with the noise levels in both reference and evaluated images. Reporting of the Gamma Index with switched roles of the images as reference and

  4. Impact of Image Noise on Gamma Index Calculation

    Science.gov (United States)

    Chen, M.; Mo, X.; Parnell, D.; Olivera, G.; Galmarini, D.; Lu, W.

    2014-03-01

    Purpose: The Gamma Index defines an asymmetric metric between the evaluated image and the reference image. It provides a quantitative comparison that can be used to indicate sample-wised pass/fail on the agreement of the two images. The Gamma passing/failing rate has become an important clinical evaluation tool. However, the presence of noise in the evaluated and/or reference images may change the Gamma Index, hence the passing/failing rate, and further, clinical decisions. In this work, we systematically studied the impact of the image noise on the Gamma Index calculation. Methods: We used both analytic formulation and numerical calculations in our study. The numerical calculations included simulations and clinical images. Three different noise scenarios were studied in simulations: noise in reference images only, in evaluated images only, and in both. Both white and spatially correlated noises of various magnitudes were simulated. For clinical images of various noise levels, the Gamma Index of measurement against calculation, calculation against measurement, and measurement against measurement, were evaluated. Results: Numerical calculations for both the simulation and clinical data agreed with the analytic formulations, and the clinical data agreed with the simulations. For the Gamma Index of measurement against calculation, its distribution has an increased mean and an increased standard deviation as the noise increases. On the contrary, for the Gamma index of calculation against measurement, its distribution has a decreased mean and stabilized standard deviation as the noise increases. White noise has greater impact on the Gamma Index than spatially correlated noise. Conclusions: The noise has significant impact on the Gamma Index calculation and the impact is asymmetric. The Gamma Index should be reported along with the noise levels in both reference and evaluated images. Reporting of the Gamma Index with switched roles of the images as reference and

  5. Malmquist Productivity Index on Efficiency Layers

    Directory of Open Access Journals (Sweden)

    F. Rezai balf ∗

    2012-09-01

    Full Text Available Data Envelopment Analysis (DEA, a popular linear programming technique is useful to rate comparatively operational effiency of decision Making Unit (DMU based on the their deterministic inputoutput data. The Malmquist productivity index in DEA, calculable with the distance function, for measurement the productivity change among two variant time period or two variant group in the same time. This index is based on two factor of efficiency change index and a technological change index. In this paper, we operate on the collective Malmquist productivity index, which performs clustering operation DMUs with classification into different levels of efficient frontier, and then we discuss on the relation between Malmquist index on the efficiency layers and their attractiveness and progress

  6. Efficient Joins with Compressed Bitmap Indexes

    Energy Technology Data Exchange (ETDEWEB)

    Computational Research Division; Madduri, Kamesh; Wu, Kesheng

    2009-08-19

    We present a new class of adaptive algorithms that use compressed bitmap indexes to speed up evaluation of the range join query in relational databases. We determine the best strategy to process a join query based on a fast sub-linear time computation of the join selectivity (the ratio of the number of tuples in the result to the total number of possible tuples). In addition, we use compressed bitmaps to represent the join output compactly: the space requirement for storing the tuples representing the join of two relations is asymptotically bounded by min(h; n . cb), where h is the number of tuple pairs in the result relation, n is the number of tuples in the smaller of the two relations, and cb is the cardinality of the larger column being joined. We present a theoretical analysis of our algorithms, as well as experimental results on large-scale synthetic and real data sets. Our implementations are efficient, and consistently outperform well-known approaches for a range of join selectivity factors. For instance, our count-only algorithm is up to three orders of magnitude faster than the sort-merge approach, and our best bitmap index-based algorithm is 1.2x-80x faster than the sort-merge algorithm, for various query instances. We achieve these speedups by exploiting several inherent performance advantages of compressed bitmap indexes for join processing: an implicit partitioning of the attributes, space-efficiency, and tolerance of high-cardinality relations.

  7. Efficient protein structure search using indexing methods.

    Science.gov (United States)

    Kim, Sungchul; Sael, Lee; Yu, Hwanjo

    2013-01-01

    Understanding functions of proteins is one of the most important challenges in many studies of biological processes. The function of a protein can be predicted by analyzing the functions of structurally similar proteins, thus finding structurally similar proteins accurately and efficiently from a large set of proteins is crucial. A protein structure can be represented as a vector by 3D-Zernike Descriptor (3DZD) which compactly represents the surface shape of the protein tertiary structure. This simplified representation accelerates the searching process. However, computing the similarity of two protein structures is still computationally expensive, thus it is hard to efficiently process many simultaneous requests of structurally similar protein search. This paper proposes indexing techniques which substantially reduce the search time to find structurally similar proteins. In particular, we first exploit two indexing techniques, i.e., iDistance and iKernel, on the 3DZDs. After that, we extend the techniques to further improve the search speed for protein structures. The extended indexing techniques build and utilize an reduced index constructed from the first few attributes of 3DZDs of protein structures. To retrieve top-k similar structures, top-10 × k similar structures are first found using the reduced index, and top-k structures are selected among them. We also modify the indexing techniques to support θ-based nearest neighbor search, which returns data points less than θ to the query point. The results show that both iDistance and iKernel significantly enhance the searching speed. In top-k nearest neighbor search, the searching time is reduced 69.6%, 77%, 77.4% and 87.9%, respectively using iDistance, iKernel, the extended iDistance, and the extended iKernel. In θ-based nearest neighbor serach, the searching time is reduced 80%, 81%, 95.6% and 95.6% using iDistance, iKernel, the extended iDistance, and the extended iKernel, respectively.

  8. Analytical calculations of the efficiency of gamma scintillators total efficiency for coaxial disk sources

    Energy Technology Data Exchange (ETDEWEB)

    Selim, Y S; Abbas, M I; Fawzy, M A [Physics Department, Faculty of Science, Alexandria University, Aleaxndria (Egypt)

    1997-12-31

    Total efficiency of clad right circular cylindrical Nal(TI) scintillation detector from a coaxial isotropic radiating circular disk source has been calculated by the of rigid mathematical expressions. Results were tabulated for various gamma energies. 2 figs., 5 tabs.

  9. Towards Efficient Positional Inverted Index

    Directory of Open Access Journals (Sweden)

    Petr Procházka

    2017-02-01

    Full Text Available We address the problem of positional indexing in the natural language domain. The positional inverted index contains the information of the word positions. Thus, it is able to recover the original text file, which implies that it is not necessary to store the original file. Our Positional Inverted Self-Index (PISI stores the word position gaps encoded by variable byte code. Inverted lists of single terms are combined into one inverted list that represents the backbone of the text file since it stores the sequence of the indexed words of the original file. The inverted list is synchronized with a presentation layer that stores separators, stop words, as well as variants of the indexed words. The Huffman coding is used to encode the presentation layer. The space complexity of the PISI inverted list is O ( ( N − n ⌈ log 2 b N ⌉ + ( ⌊ N − n α ⌋ + n × ( ⌈ log 2 b n ⌉ + 1 where N is a number of stems, n is a number of unique stems, α is a step/period of the back pointers in the inverted list and b is the size of the word of computer memory given in bits. The space complexity of the presentation layer is O ( − ∑ i = 1 N ⌈ log 2 p i n ( i ⌉ − ∑ j = 1 N ′ ⌈ log 2 p j ′ ⌉ + N with respect to p i n ( i as a probability of a stem variant at position i, p j ′ as the probability of separator or stop word at position j and N ′ as the number of separators and stop words.

  10. On the functional form of an efficiency index

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Keiding, Hans

    1998-01-01

    An input efficiency index gives a numeric assessment of the degree to which a given input combination falls short of being efficient in producing a fixed amount of output. This paper presents a system of axioms which characterise a certain family of efficiency indices containing the well-known Fa...

  11. Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

    Energy Technology Data Exchange (ETDEWEB)

    Sumida, Iori, E-mail: sumida@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Yamaguchi, Hajime; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yoshikawa, Nobuhiko; Yamada, Yuji [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Suzuki, Osamu; Seo, Yuji [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Isohashi, Fumiaki [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan); Yoshioka, Yasuo [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Ogawa, Kazuhiko [Department of Radiation Oncology, NTT West Osaka Hospital, Osaka (Japan)

    2015-07-15

    Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV, spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.

  12. Selection of index complex for the NPP operator activity efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Kolesnik, A I; Chertorizhskij, E A

    1984-01-01

    Preconditions for choice of NPP operator activity efficiency index are determined. Results of the choice are given and a method for determination of generalized and particular parameters by means of which NPP operator activity efficiency can be estimated is considered. An algorithm of diagnosis of reason for unsuccess of operator activity based on assessment of psychological factors of complicacy is suggested.

  13. Interpretation of Gamma Index for Quality Assurance of Simultaneously Integrated Boost (SIB) IMRT Plans for Head and Neck Carcinoma

    Science.gov (United States)

    Atiq, Maria; Atiq, Atia; Iqbal, Khalid; Shamsi, Quratul ain; Andleeb, Farah; Buzdar, Saeed Ahmad

    2017-12-01

    Objective: The Gamma Index is prerequisite to estimate point-by-point difference between measured and calculated dose distribution in terms of both Distance to Agreement (DTA) and Dose Difference (DD). This study aims to inquire what percentage of pixels passing a certain criteria assure a good quality plan and suggest gamma index as efficient mechanism for dose verification of Simultaneous Integrated Boost Intensity Modulated Radiotherapy plans. Method: In this study, dose was calculated for 14 head and neck patients and IMRT Quality Assurance was performed with portal dosimetry using the Eclipse treatment planning system. Eclipse software has a Gamma analysis function to compare measured and calculated dose distribution. Plans of this study were deemed acceptable when passing rate was 95% using tolerance for Distance to agreement (DTA) as 3mm and Dose Difference (DD) as 5%. Result and Conclusion: Thirteen cases pass tolerance criteria of 95% set by our institution. Confidence Limit for DD is 9.3% and for gamma criteria our local CL came out to be 2.0% (i.e., 98.0% passing). Lack of correlation was found between DD and γ passing rate with R2 of 0.0509. Our findings underline the importance of gamma analysis method to predict the quality of dose calculation. Passing rate of 95% is achieved in 93% of cases which is adequate level of accuracy for analyzed plans thus assuring the robustness of SIB IMRT treatment technique. This study can be extended to investigate gamma criteria of 5%/3mm for different tumor localities and to explore confidence limit on target volumes of small extent and simple geometry.

  14. Fast and efficient indexing approach for object recognition

    Science.gov (United States)

    Hefnawy, Alaa; Mashali, Samia A.; Rashwan, Mohsen; Fikri, Magdi

    1999-08-01

    This paper introduces a fast and efficient indexing approach for both 2D and 3D model-based object recognition in the presence of rotation, translation, and scale variations of objects. The indexing entries are computed after preprocessing the data by Haar wavelet decomposition. The scheme is based on a unified image feature detection approach based on Zernike moments. A set of low level features, e.g. high precision edges, gray level corners, are estimated by a set of orthogonal Zernike moments, calculated locally around every image point. A high dimensional, highly descriptive indexing entries are then calculated based on the correlation of these local features and employed for fast access to the model database to generate hypotheses. A list of the most candidate models is then presented by evaluating the hypotheses. Experimental results are included to demonstrate the effectiveness of the proposed indexing approach.

  15. A simple and efficient gamma irradiator for RVNRL

    Energy Technology Data Exchange (ETDEWEB)

    Smolko, E; Ferenaz, G; Docters, E [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Makuuchi, Keizo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-12-31

    This work describes a new design of a gamma irradiator for RVNRL which obeys a reliable operation and an efficient economical equation. Our irradiator is of a nobel design according to present requirements of latex industries and to the state of the art of radiation technology. The irradiator is of a wet storage type, where the radioactive sources are fixed in the reactor vessel, permanently submerged in deionized water. Preformulated latex is pumped from a deposited vessel into the reactor vessel and it is recirculated during the irradiation cycle avoiding turbulences and dose inhomogeneities. The irradiation time per one ton batch with a Co-60 charge of 3.5E15 Bq (100 kCi) is of approximately 4 hours

  16. A simple and efficient gamma irradiator for RVNRL

    International Nuclear Information System (INIS)

    Smolko, E.; Ferenaz, G.; Docters, E.; Keizo Makuuchi

    1996-01-01

    This work describes a new design of a gamma irradiator for RVNRL which obeys a reliable operation and an efficient economical equation. Our irradiator is of a nobel design according to present requirements of latex industries and to the state of the art of radiation technology. The irradiator is of a wet storage type, where the radioactive sources are fixed in the reactor vessel, permanently submerged in deionized water. Preformulated latex is pumped from a deposited vessel into the reactor vessel and it is recirculated during the irradiation cycle avoiding turbulences and dose inhomogeneities. The irradiation time per one ton batch with a Co-60 charge of 3.5E15 Bq (100 kCi) is of approximately 4 hours

  17. Human Development Index and Efficiency level of Social Security Hospitals

    Directory of Open Access Journals (Sweden)

    H. Sepehrdost

    2012-04-01

    Full Text Available Introduction & Objective: Hospitals as one of the main institutions providing health care services play an important role in the health system and allocate a high percentage of health sector's budget to them. This study aimed to answer whether social security hospitals efficiency levels are the same for all provinces in Iran? And whether any relationship exists between the human development indexes (HDI of the provinces and technical efficiency levels of the hospitals?Materials & Methods: Data envelopment analysis model has been used to measure technical efficiency of 65 social security hospitals, including small hospitals (working with lower than one hundred active beds and large hospitals (working with over one hundred active beds during the years 2007 to 2009. Further, the relationship between human development index and technical efficiency of hospitals in the provinces has been analyzed.Results: Results show that the average technical efficiency of small and large hospitals working in low and medium HDI provinces (0.912 and 0.937 are more than the average technical efficiency of hospitals in higher HDI provinces (0.870 and 0.887.Conclusion: It is recommended that social security organization concentrated distribute its hospital services in provinces with lower HDI and higher density of population living under the coverage of organization’s insurance. This will eventually puts its positive effects on per capita income of people, as well as more equitable distribution of income. (Sci J Hamadan Univ Med Sci 2012;19(1:32-38

  18. Efficiency factor of a chemical nuclear reactor with gamma sources

    International Nuclear Information System (INIS)

    Anguis T, C.

    1975-01-01

    A chemonuclear reactor is simulated in order to calculate the efficiency factor of molecular species in chemical reactions induced by gamma radiation, with the purpose to obtain information for its design and consider the electromagnetic energy as a possible solution to the present problem of energy. The research is based on a mathematical model of succesive Compton processes applied to spherical and cylindrical geometry and corroborated through the absorbed dose and the experimental date of the increase factor, for the radioisotopic sources Co-60 and Cs-137 relating the quantity of energy deposited into various cylinders with the G value, the relation radius/height of the reactor is optimized according to the molecular production. This is illustrated with the radiolysis of a solution of CH 3 OH/H 2 O which forms H 2 and with the obtainment of C 2 H 5 Br that represents and industrial process induced radioactively. The results show a greater energy deposition with Cs-137 but a larger production of H 2 /hr with Co-60, and besides we can find high production values of C 2 H 5 Br. The cylinder with more advantages is that whose relation R/H is of 0.5. It can be concluded that the final selection of the reactor should be made after a more intense study of the used isotope and the source activity. The efficiency factor of H 2 can be increased selecting the appropriate type and concentration of solute of the irradiated aqueous solutions

  19. A combined sustainability index for electricity efficiency measures

    International Nuclear Information System (INIS)

    Goldrath, T.; Ayalon, O.; Shechter, M.

    2015-01-01

    One of the most substantial tools that serve decision makers in their efforts to reduce greenhouse gas emissions includes energy efficiency measures that in most cases benefit from governmental assistance for achieving electricity consumption reduction goals. This paper examines five energy efficiency measures, defining a combined sustainability index. A multi-criteria analysis of five predefined indices was developed (economic, environmental, technology, social and political), providing a combined index for each measure and a tool for identifying the preferred measure within a specific situation, based on its total sustainability score. In this research, a case study was conducted and the preferred measure was found to be municipal street lighting systems, based on its high political and social scores, and its relatively high installation potential. The second choice would be replacement of chillers in the industrial sector, and the least favorable measure is the replacement of water pumps in the water sector. The methodology described brings into account the technological specifications of the measure implemented, and the specific national conditions under which it is implemented. - Highlights: • A MCDA of five indices was developed to define a combined sustainability index. • Criteria defined were environment, technology, economy, social and political. • Five energy efficiency measures were rated, based on their total sustainability score. • Measures were in five main electricity consumption sectors. • The preferred measure found in the case study was municipal street lighting systems.

  20. Probing a Possible Vacuum Refractive Index with Gamma-Ray Telescopes

    CERN Document Server

    Ellis, John; Nanopoulos, D V; PH-TH

    2009-01-01

    We have used a stringy model of quantum space-time foam to suggest that the vacuum may exhibit a non-trivial refractive index depending linearly on gamma-ray energy: eta -1 ~ E_gamma/M_QG1, where M_QG1 is some mass scale typical of quantum gravity that may be ~ 10^18 GeV: see Phys. Lett. B 665, 412 (2008) and references therein. The MAGIC, HESS and Fermi gamma-ray telescopes have recently probed the possible existence of such an energy-dependent vacuum refractive index. All find indications of time-lags for higher-energy photons, but cannot exclude the possibility that they are due to intrinsic delays at the sources. However, the MAGIC and HESS observations of time-lags in emissions from AGNs Mkn 501 and PKS 2155-304 are compatible with each other and a refractive index depending linearly on the gamma-ray energy, with M_QG1 ~ 10^18 GeV. We combine their results to estimate the time-lag Delta t to be expected for the highest-energy photon from GRB 080916c measured by the Fermi telescope, which has an energy ~ ...

  1. Efficiency curves of NIRR-1 gamma-ray spectrometry system at near ...

    African Journals Online (AJOL)

    The full-energy peak efficiency curves of the gamma-ray spectrometry for use with the Nigeria Research Reactor-1 (NIRR-1) have been determined by both theoretical and experimental at two source-detector positions for routine neutron activation analysis. Standard gamma ray sources were used to determine the efficiency ...

  2. Design of a software for gamma detector efficiency

    International Nuclear Information System (INIS)

    Lopez, G.

    2011-01-01

    Gamma spectroscopy with highly-pure-germanium detector is one of the most used method for qualitative and quantitative analysis of samples. Nevertheless Gamma spectroscopy results require to be corrected, first for taking into account the self-shielding effect that represents the absorption of the photons by the sample itself and secondly for correcting the fact that 2 photons emitted simultaneously with energy E 1 and E 2 are likely to be simultaneously detected and then counted as a single photon with an energy E 1 +E 2 . This effect is called gamma-gamma coincidence. A software has been designed to simulate both effect and produce correcting factors in the case of cylindrical geometries. This software has been validated on Americium 241 for the self-shielding effect and on Cesium 134 for gamma-gamma coincidence. (A.C.)

  3. Gamma-index method sensitivity for gauging plan delivery accuracy of volumetric modulated arc therapy.

    Science.gov (United States)

    Park, Jong In; Park, Jong Min; Kim, Jung-In; Park, So-Yeon; Ye, Sung-Joon

    2015-12-01

    The aim of this study was to investigate the sensitivity of the gamma-index method according to various gamma criteria for volumetric modulated arc therapy (VMAT). Twenty head and neck (HN) and twenty prostate VMAT plans were retrospectively selected for this study. Both global and local 2D gamma evaluations were performed with criteria of 3%/3 mm, 2%/2 mm, 1%/2 mm and 2%/1 mm. In this study, the global and local gamma-index calculated the differences in doses relative to the maximum dose and the dose at the current measurement point, respectively. Using log files acquired during delivery, the differences in parameters at every control point between the VMAT plans and the log files were acquired. The differences in dose-volumetric parameters between reconstructed VMAT plans using the log files and the original VMAT plans were calculated. The Spearman's rank correlation coefficients (rs) were calculated between the passing rates and those differences. Considerable correlations with statistical significances were observed between global 1%/2 mm, local 1%/2 mm and local 2%/1 mm and the MLC position differences (rs = -0.712, -0.628 and -0.581). The numbers of rs values with statistical significance between the passing rates and the changes in dose-volumetric parameters were largest in global 2%/2 mm (n = 16), global 2%/1 mm (n = 15) and local 2%/1 mm (n = 13) criteria. Local gamma-index method with 2%/1 mm generally showed higher sensitivity to detect deviations between a VMAT plan and the delivery of the VMAT plan. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. THE BRAKING INDEX OF A RADIO-QUIET GAMMA-RAY PULSAR

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C. J.; Pletsch, H. J.; Allen, B.; Aulbert, C.; Beer, C.; Bock, O.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Machenschalk, B.; Nieder, L. [Albert-Einstein-Institut, Max-Planck-Institut für Gravitationsphysik, D-30167 Hannover (Germany); Wu, J.; Guillemot, L.; Kramer, M. [Max-Planck-Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany); Camilo, F. [SKA South Africa, Pinelands, 7405 (South Africa); Johnson, T. J. [College of Science, George Mason University, Fairfax, VA 22030 (United States); Kerr, M., E-mail: colin.clark@aei.mpg.de [CSIRO Astronomy and Space Science, Australia Telescope National Facility, Epping, NSW 1710 (Australia)

    2016-11-20

    We report the discovery and timing measurements of PSR J1208−6238, a young and highly magnetized gamma-ray pulsar, with a spin period of 440 ms. The pulsar was discovered in gamma-ray photon data from the Fermi Large Area Telescope (LAT) during a blind-search survey of unidentified LAT sources, running on the distributed volunteer computing system Einstein@Home . No radio pulsations were detected in dedicated follow-up searches with the Parkes radio telescope, with a flux density upper limit at 1369 MHz of 30 μ Jy. By timing this pulsar’s gamma-ray pulsations, we measure its braking index over five years of LAT observations to be n = 2.598 ± 0.001 ± 0.1, where the first uncertainty is statistical and the second estimates the bias due to timing noise. Assuming its braking index has been similar since birth, the pulsar has an estimated age of around 2700 years, making it the youngest pulsar to be found in a blind search of gamma-ray data and the youngest known radio-quiet gamma-ray pulsar. Despite its young age, the pulsar is not associated with any known supernova remnant or pulsar wind nebula. The pulsar’s inferred dipolar surface magnetic field strength is 3.8 × 10{sup 13} G, almost 90% of the quantum-critical level. We investigate some potential physical causes of the braking index deviating from the simple dipole model but find that LAT data covering a longer time interval will be necessary to distinguish between these.

  5. THE BRAKING INDEX OF A RADIO-QUIET GAMMA-RAY PULSAR

    International Nuclear Information System (INIS)

    Clark, C. J.; Pletsch, H. J.; Allen, B.; Aulbert, C.; Beer, C.; Bock, O.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Machenschalk, B.; Nieder, L.; Wu, J.; Guillemot, L.; Kramer, M.; Camilo, F.; Johnson, T. J.; Kerr, M.

    2016-01-01

    We report the discovery and timing measurements of PSR J1208−6238, a young and highly magnetized gamma-ray pulsar, with a spin period of 440 ms. The pulsar was discovered in gamma-ray photon data from the Fermi Large Area Telescope (LAT) during a blind-search survey of unidentified LAT sources, running on the distributed volunteer computing system Einstein@Home . No radio pulsations were detected in dedicated follow-up searches with the Parkes radio telescope, with a flux density upper limit at 1369 MHz of 30 μ Jy. By timing this pulsar’s gamma-ray pulsations, we measure its braking index over five years of LAT observations to be n = 2.598 ± 0.001 ± 0.1, where the first uncertainty is statistical and the second estimates the bias due to timing noise. Assuming its braking index has been similar since birth, the pulsar has an estimated age of around 2700 years, making it the youngest pulsar to be found in a blind search of gamma-ray data and the youngest known radio-quiet gamma-ray pulsar. Despite its young age, the pulsar is not associated with any known supernova remnant or pulsar wind nebula. The pulsar’s inferred dipolar surface magnetic field strength is 3.8 × 10 13 G, almost 90% of the quantum-critical level. We investigate some potential physical causes of the braking index deviating from the simple dipole model but find that LAT data covering a longer time interval will be necessary to distinguish between these.

  6. Absolute peak detection efficiencies of a Ge(Li) detector for high gamma-ray energies

    International Nuclear Information System (INIS)

    Katagiri, Masaki

    1985-11-01

    Absolute peak detection efficiencies of a Ge(Li) detector for gamma-rays of 3.5 MeV to 12 MeV were measured using four (p,γ) reactions and a (n,γ) reaction. Two-line-method was used to obtaine peak detection efficiencies. The efficiencies with the both cases are agreed very well. Utilization of (n,γ) reaction is, therefore, effective for measuring these efficiencies, because high energy gamma-rays can be generated easily by using a neutron source. These results were applied to calibration of a gamma-ray standard source, emitting 6.13 MeV gamma-rays, and of intensities of 56 Co standard gamma-ray source. (author)

  7. Mutagenic effectiveness and efficiency of EMS, DES and gamma-rays in rice

    International Nuclear Information System (INIS)

    Kaul, M.L.H.; Bhan, A.K.

    1977-01-01

    Data on chlorophyll mutation frequency after treatment with EMS, DES and gamma-rays and sequential administration of gamma-rays and the two alkylating agents in three varieties of rice have been used to work out quantitatively the effectiveness and efficiency of each mutagen and combination treatment. For effectiveness, the order is EMS > DES and for efficiency it is EMS > DES > gamma-rays. In some sequential treatments (Gamma-rays + DES in 'IR8' and 'Basmati'; DES + gamma-rays in 'IR8' and 'Jhona'; Gamma-rays + EMS in 'IR8' and 'Basmati'; and EMS + gamma-rays in 'IR8', 'Jhona' and 'Basmati') mutation frequency is more than additive (synergistic) but these treatments are decisively less efficient because of their relatively high injurious effects in the M 1 generation. EMS induces more albinas than gamma-rays do. The mutational spectrum patterns induced by gamma-rays and DES are alike. In general, combination treatments tend to increase the frequency of albinas over other types of chlorophyll mutants. (orig.) [de

  8. Myasthenia Gravis Impairment Index: Responsiveness, meaningful change, and relative efficiency.

    Science.gov (United States)

    Barnett, Carolina; Bril, Vera; Kapral, Moira; Kulkarni, Abhaya V; Davis, Aileen M

    2017-12-05

    To study responsiveness and meaningful change of the Myasthenia Gravis Impairment Index (MGII) and its relative efficiency compared to other measures. We enrolled 95 patients receiving prednisone, IV immunoglobulin (IVIg), or plasma exchange (PLEX) and 54 controls. Patients were assessed with the MGII and other measures-including the Quantitative Myasthenia Gravis Score, Myasthenia Gravis Composite, and Myasthenia Gravis Activities of Daily Living-at baseline and 3-4 weeks after treatment. Statistical markers of responsiveness included between-groups and within-group differences, and we estimated the relative efficiency of the MGII compared to other measures. Patient-meaningful change was assessed with an anchor-based method, using the patient's impression of change. We determined the minimal detectable change (MDC) and the minimal important difference (MID) at the group and individual level. Treated patients had a higher change in MGII scores than controls (analysis of covariance p 1 favoring the MGII. The MGII demonstrated responsiveness to prednisone, IVIg, and PLEX in patients with myasthenia. There is a differential response in ocular and generalized symptoms to type of therapy. The MGII has higher relative efficiency than comparison measures and is viable for use in clinical trials. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  9. Beta, but not gamma, band oscillations index visual form-motion integration.

    Directory of Open Access Journals (Sweden)

    Charles Aissani

    Full Text Available Electrophysiological oscillations in different frequency bands co-occur with perceptual, motor and cognitive processes but their function and respective contributions to these processes need further investigations. Here, we recorded MEG signals and seek for percept related modulations of alpha, beta and gamma band activity during a perceptual form/motion integration task. Participants reported their bound or unbound perception of ambiguously moving displays that could either be seen as a whole square-like shape moving along a Lissajou's figure (bound percept or as pairs of bars oscillating independently along cardinal axes (unbound percept. We found that beta (15-25 Hz, but not gamma (55-85 Hz oscillations, index perceptual states at the individual and group level. The gamma band activity found in the occipital lobe, although significantly higher during visual stimulation than during base line, is similar in all perceptual states. Similarly, decreased alpha activity during visual stimulation is not different for the different percepts. Trial-by-trial classification of perceptual reports based on beta band oscillations was significant in most observers, further supporting the view that modulation of beta power reliably index perceptual integration of form/motion stimuli, even at the individual level.

  10. Efficient Asymmetric Index Encapsulation Scheme for Anonymous Content Centric Networking

    Directory of Open Access Journals (Sweden)

    Rong Ma

    2017-01-01

    Full Text Available Content Centric Networking (CCN is an effective communication paradigm that well matches the features of wireless environments. To be considered a viable candidate in the emerging wireless networks, despite the clear benefits of location-independent security, CCN must at least have parity with existing solutions for confidential and anonymous communication. This paper designs a new cryptographic scheme, called Asymmetric Index Encapsulation (AIE, that enables the router to test whether an encapsulated header matches the token without learning anything else about both of them. We suggest using the AIE as the core protocol of anonymous Content Centric Networking. A construction of AIE which strikes a balance between efficiency and security is given. The scheme is proved to be secure based on the DBDH assumption in the random oracle with tight reduction, while the encapsulated header and the token in our system consist of only three elements.

  11. Effect of gamma radiation on ''in vitro''' efficiency of fungicides

    International Nuclear Information System (INIS)

    Menten, J.O.M.; Oliveira, G.C.X.

    1984-01-01

    The activity of 60 Co gamma radiation on eight fungicides used in post-harvesting treatment of agricultural products, was studied. Rhizoctonia solani was used in biological test as indicator-fungus. The fungicides were submitted to gamma radiation doses of O (control), 1, 10, 100, 1000 and 10.000 kR, samples of the fungicides were added to the PSA culture media to obtain 0, 1, 10 and 100 ppm concentrations of the active component of each product and of each radiation dose. The ED 50 (concentration of fungicide necessary to cause 50% radial reduction of the fungic mycelium) of each fungicide in the different gamma radiation doses was determined. (M.A.C.) [pt

  12. Studies on safety and efficiency of gamma-irradiated ginseng

    International Nuclear Information System (INIS)

    Kwon, Joong Ho; Cho, Han Ok; Byun, Myung Wo; Kim, Suc Won; Yang, Jae Seong; Yoo, Young Soo; Jin, Joon Ha; Park, Soon Chul

    1991-09-01

    Gamma irradiation was applied to the biological quality improvement and preservation of white ginseng which has problems in a hygienic quality and storage stability. The current phosphine treatment showed no influence on microorganisms contaminated even though it was very useful for disinfestation of the sample, while 5 kGy irradiation effectively controlled the biological quality of the stored sample, with minimal effects on the quality parameters of white ginseng. Thus, it is concluded that gamma irradiation at a range of 5 kGy can be an alternative method of chemical fumigants provided air-tight packaging excluding recontamination is used for the stored product. (Author)

  13. Evaluation of the radiobiological gamma index with motion interplay in tangential IMRT breast treatment

    Science.gov (United States)

    Sumida, Iori; Yamaguchi, Hajime; Das, Indra J.; Kizaki, Hisao; Aboshi, Keiko; Tsujii, Mari; Yamada, Yuji; Tamari, Kiesuke; Suzuki, Osamu; Seo, Yuji; Isohashi, Fumiaki; Yoshioka, Yasuo; Ogawa, Kazuhiko

    2016-01-01

    The purpose of this study was to evaluate the impact of the motion interplay effect in early-stage left-sided breast cancer intensity-modulated radiation therapy (IMRT), incorporating the radiobiological gamma index (RGI). The IMRT dosimetry for various breathing amplitudes and cycles was investigated in 10 patients. The predicted dose was calculated using the convolution of segmented measured doses. The physical gamma index (PGI) of the planning target volume (PTV) and the organs at risk (OAR) was calculated by comparing the original with the predicted dose distributions. The RGI was calculated from the PGI using the tumor control probability (TCP) and the normal tissue complication probability (NTCP). The predicted mean dose and the generalized equivalent uniform dose (gEUD) to the target with various breathing amplitudes were lower than the original dose (P < 0.01). The predicted mean dose and gEUD to the OARs with motion were higher than for the original dose to the OARs (P < 0.01). However, the predicted data did not differ significantly between the various breathing cycles for either the PTV or the OARs. The mean RGI gamma passing rate for the PTV was higher than that for the PGI (P < 0.01), and for OARs, the RGI values were higher than those for the PGI (P < 0.01). The gamma passing rates of the RGI for the target and the OARs other than the contralateral lung differed significantly from those of the PGI under organ motion. Provided an NTCP value <0.05 is considered acceptable, it may be possible, by taking breathing motion into consideration, to escalate the dose to achieve the PTV coverage without compromising the TCP. PMID:27534793

  14. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  15. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  16. Development of software for the determination of gamma ray detection efficiency

    International Nuclear Information System (INIS)

    Silva, Antonio C.O. da; Genezini, Frederico A.; Zahn, Guilherme S.

    2009-01-01

    Gamma spectrometry is frequently used as a tool in analytical chemistry or environmental analyses. The efficiency of the detection setup is one of most important steps of the analyses, but users don't always calculate their own efficiency curve because this procedure is not trivial, and therefore they adapt their measurement geometry to work in a setup that has been previously calibrated, which will often cause limitations. In order to solve this problem, a software was developed that helps a non-experienced user to compute the detection efficiency curve and to determine the detection efficiency at a given gamma-ray energy. (author)

  17. Evaluation of efficiency of a semiconductor gamma camera

    CERN Document Server

    Otake, H; Takeuchi, Y

    2002-01-01

    We evaluation basic characteristics of a compact type semiconductor gamma camera (eZ-SCOPE AN) of Cadmium Zinc Telluride (CdZnTe). This new compact gamma camera has 256 semiconductors representing the same number of pixels. Each semiconductor is 2 mm square and is located in 16 lines and rows on the surface of the detector. The specific performance characteristics were evaluated in the study referring to National Electrical Manufactures Association (NEMA) standards; intrinsic energy resolution, intrinsic count rate performance, integral uniformity, system planar sensitivity, system spatial resolution, and noise to the neighboring pixels. The intrinsic energy resolution measured 5.7% as full width half maximum (FWHM). The intrinsic count rate performance ranging from 17 kcps to 1,285 kcps was evaluated, but the highest intrinsic count rate was not observed. Twenty percents count loss was recognized at 1,021 kcps. The integral uniformity was 1.3% with high sensitivity collimator. The system planar sensitivity w...

  18. Plan Quality and Treatment Efficiency for Radiosurgery to Multiple Brain Metastases: Non-Coplanar RapidArc vs Gamma Knife

    Directory of Open Access Journals (Sweden)

    Haisong eLiu

    2016-02-01

    Full Text Available Objectives: This study compares the dosimetry and efficiency of two modern radiosurgery (SRS modalities for multiple brain metastases (Gamma Knife and LINAC-based RapidArc/volumetric modulated arc therapy, with a special focus on the comparison of low dose spread.Methods: Six patients with three or four small brain metastases were used in this study. The size of targets varied from 0.1 ~ 10.5 cc. SRS doses were prescribed according to size of lesions. SRS plans were made using both Gamma Knife® Perfexion and a single-isocenter, multiple non-coplanar RapidArc®. Dosimetric parameters analyzed included RTOG conformity index (CI, gradient index (GI, 12 Gy isodose volume (V12Gy for each target, and the dose spread (Dspread for each plan. Dspread reflects SRS plan’s capability of confining radiation to within the local vicinity of the lesion and to not spread out to the surrounding normal brain tissues. Each plan has a dose (Dspread, such that once dose decreases below Dspread (on total tissue DVH, isodose volume starts increasing dramatically. Dspread is defined as that dose when volume increase first exceeds 20 cc per 0.1 Gy dose decrease. Results: RapidArc SRS has smaller CI (1.19 ±0.14 vs. 1.50 ± 0.16, p<0.001 and larger GI (4.77 ± 1.49 vs. 3.65 ± 0.98, p <0.01. V12Gy results were comparable (2.73 ± 1.38 cc vs. 3.06 ± 2.20 cc, p = 0.58. Moderate to lower dose spread, V6, V4.5, and V3, were also equivalent. Gamma Knife plans achieved better very low dose spread (≤3 Gy and also had slightly smaller Dspread, 1.9 Gy vs 2.5 Gy. Total treatment time for Gamma Knife is estimated between 60~100 min. Gamma Knife treatments are between 3~5 times longer compared to RapidArc treatment techniques.Conclusion: Dosimetric parameters reflecting prescription dose conformality (CI, dose fall off (GI, radiation necrosis indicator (V12Gy, and dose spread (Dspread were compared between Gamma Knife SRS and RapidArc SRS for multi-mets. RapidArc plans have

  19. Indexed variation graphs for efficient and accurate resistome profiling.

    Science.gov (United States)

    Rowe, Will P M; Winn, Martyn D

    2018-05-14

    Antimicrobial resistance remains a major threat to global health. Profiling the collective antimicrobial resistance genes within a metagenome (the "resistome") facilitates greater understanding of antimicrobial resistance gene diversity and dynamics. In turn, this can allow for gene surveillance, individualised treatment of bacterial infections and more sustainable use of antimicrobials. However, resistome profiling can be complicated by high similarity between reference genes, as well as the sheer volume of sequencing data and the complexity of analysis workflows. We have developed an efficient and accurate method for resistome profiling that addresses these complications and improves upon currently available tools. Our method combines a variation graph representation of gene sets with an LSH Forest indexing scheme to allow for fast classification of metagenomic sequence reads using similarity-search queries. Subsequent hierarchical local alignment of classified reads against graph traversals enables accurate reconstruction of full-length gene sequences using a scoring scheme. We provide our implementation, GROOT, and show it to be both faster and more accurate than a current reference-dependent tool for resistome profiling. GROOT runs on a laptop and can process a typical 2 gigabyte metagenome in 2 minutes using a single CPU. Our method is not restricted to resistome profiling and has the potential to improve current metagenomic workflows. GROOT is written in Go and is available at https://github.com/will-rowe/groot (MIT license). will.rowe@stfc.ac.uk. Supplementary data are available at Bioinformatics online.

  20. Application of the EXtrapolated Efficiency Method (EXEM) to infer the gamma-cascade detection efficiency in the actinide region

    International Nuclear Information System (INIS)

    Ducasse, Q.; Jurado, B.; Mathieu, L.; Marini, P.; Morillon, B.; Aiche, M.; Tsekhanovich, I.

    2016-01-01

    The study of transfer-induced gamma-decay probabilities is very useful for understanding the surrogate-reaction method and, more generally, for constraining statistical-model calculations. One of the main difficulties in the measurement of gamma-decay probabilities is the determination of the gamma-cascade detection efficiency. In Boutoux et al. (2013) [10] we developed the EXtrapolated Efficiency Method (EXEM), a new method to measure this quantity. In this work, we have applied, for the first time, the EXEM to infer the gamma-cascade detection efficiency in the actinide region. In particular, we have considered the "2"3"8U(d,p)"2"3"9U and "2"3"8U("3He,d)"2"3"9Np reactions. We have performed Hauser–Feshbach calculations to interpret our results and to verify the hypothesis on which the EXEM is based. The determination of fission and gamma-decay probabilities of "2"3"9Np below the neutron separation energy allowed us to validate the EXEM.

  1. Application of the EXtrapolated Efficiency Method (EXEM) to infer the gamma-cascade detection efficiency in the actinide region

    Energy Technology Data Exchange (ETDEWEB)

    Ducasse, Q. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); CEA-Cadarache, DEN/DER/SPRC/LEPh, 13108 Saint Paul lez Durance (France); Jurado, B., E-mail: jurado@cenbg.in2p3.fr [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Mathieu, L.; Marini, P. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France); Morillon, B. [CEA DAM DIF, 91297 Arpajon (France); Aiche, M.; Tsekhanovich, I. [CENBG, CNRS/IN2P3-Université de Bordeaux, Chemin du Solarium B.P. 120, 33175 Gradignan (France)

    2016-08-01

    The study of transfer-induced gamma-decay probabilities is very useful for understanding the surrogate-reaction method and, more generally, for constraining statistical-model calculations. One of the main difficulties in the measurement of gamma-decay probabilities is the determination of the gamma-cascade detection efficiency. In Boutoux et al. (2013) [10] we developed the EXtrapolated Efficiency Method (EXEM), a new method to measure this quantity. In this work, we have applied, for the first time, the EXEM to infer the gamma-cascade detection efficiency in the actinide region. In particular, we have considered the {sup 238}U(d,p){sup 239}U and {sup 238}U({sup 3}He,d){sup 239}Np reactions. We have performed Hauser–Feshbach calculations to interpret our results and to verify the hypothesis on which the EXEM is based. The determination of fission and gamma-decay probabilities of {sup 239}Np below the neutron separation energy allowed us to validate the EXEM.

  2. Gamma index evaluation of IMRT technique using gafchromic film EBT3 for homogeneous and inhomogeneous material

    Science.gov (United States)

    Nisauf, T. A.; Wibowo, W. E.; Pawiro, S. A.

    2017-07-01

    This study was done to evaluate the gamma index for registering between the planar of dose planning and the measurement of EBT film. The treatment plan was simulated for 5 patients using Fan Beam Computerized Tomography (FBCT) modality, Philips Pinnacle planning system, 6 MV photon energy, 50 segments IMRT technique, and calculation grid resolution (CGR) of 0.2 cm. Gamma Index (GI) evaluation was done with criteria of dose difference (DD) of 2 %, dose to agreement (DTA) of 2 mm and dose difference (DD) of 5 % DTA of 3 mm, SAD 100 cm, depth of 5 cm and 10 cm of the phantom. The result shows that GI for homogeneous material is greater than for inhomogeneous material with discrepancy to previous work is about 1.98 % for homogeneous material (depth 5 cm) and 2.05 % (depth 10 cm) while it was found of 2.98 % for inhomogeneous material (equivalent depth 5 cm) and 4.59 % (equivalent depth 10 cm).

  3. SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

    International Nuclear Information System (INIS)

    Ahmed, S; Ahmed, S; Ahmed, F; Hussain, A

    2016-01-01

    Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and plan quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.

  4. SU-F-T-266: Dynalogs Based Evaluation of Different Dose Rate IMRT Using DVH and Gamma Index

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, S [Aga Khan University Hospital, Karachi, Sindh (Pakistan); Ahmed, S [Pakistan Inst of Eng Applied Sciences, Islamabad (Pakistan); Ahmed, F; Hussain, A

    2016-06-15

    Purpose: This work investigates the impact of low and high dose rate on IMRT through Dynalogs by evaluating Gamma Index and Dose Volume Histogram. Methods: The Eclipse™ treatment planning software was used to generate plans on prostate and head and neck sites. A range of dose rates 300 MU/min and 600 MU/min were applied to each plan in order to investigate their effect on the beam ON time, efficiency and accuracy. Each plan had distinct monitor units per fraction, delivery time, mean dose rate and leaf speed. The DVH data was used in the assessment of the conformity and plan quality.The treatments were delivered on Varian™ Clinac 2100C accelerator equipped with 120 leaf millennium MLC. Dynalogs of each plan were analyzed by MATLAB™ program. Fluence measurements were performed using the Sun Nuclear™ 2D diode array and results were assessed, based on Gamma analysis of dose fluence maps, beam delivery statistics and Dynalogs data. Results: Minor differences found by adjusted R-squared analysis of DVH’s for all the plans with different dose rates. It has been also found that more and larger fields have greater time reduction at high dose rate and there was a sharp decrease in number of control points observed in dynalog files by switching dose rate from 300 MU/min to 600 MU/min. Gamma Analysis of all plans passes the confidence limit of ≥95% with greater number of passing points in 300 MU/min dose rate plans. Conclusion: The dynalog files are compatible tool for software based IMRT QA. It can work perfectly parallel to measurement based QA setup and stand-by procedure for pre and post delivery of treatment plan.

  5. An efficiency study of a high resolution gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Marti Climent, J.M.

    1987-01-01

    A review of the different curves for the efficiency fit of a high resolution gamma-ray spectrometer was made. These curves are used to fit the efficiency of our detector system. In order to study the goodness of the different fits various standards were used, and the ICRP GAM-83 exercise results were employed. (author)

  6. Study on direct determination of uranium and efficient equilibrium factor by gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Liu Chunkui

    1990-01-01

    The test principle, test set and surveying methods for conducting gamma-ray spectrometry on conveyer are presented. The conversion coefficient of the spectrometer has been found by using duallinear regression analysis of uranium and radon and their higher and lower bands of gamma-ray spectra. The efficient equilibrium factor can be quickly determined, and the direct determination of uranium in the non-equilibrium condition of uranium and radium can be made

  7. Hippocampal gamma-band Synchrony and pupillary responses index memory during visual search.

    Science.gov (United States)

    Montefusco-Siegmund, Rodrigo; Leonard, Timothy K; Hoffman, Kari L

    2017-04-01

    Memory for scenes is supported by the hippocampus, among other interconnected structures, but the neural mechanisms related to this process are not well understood. To assess the role of the hippocampus in memory-guided scene search, we recorded local field potentials and multiunit activity from the hippocampus of macaques as they performed goal-directed search tasks using natural scenes. We additionally measured pupil size during scene presentation, which in humans is modulated by recognition memory. We found that both pupil dilation and search efficiency accompanied scene repetition, thereby indicating memory for scenes. Neural correlates included a brief increase in hippocampal multiunit activity and a sustained synchronization of unit activity to gamma band oscillations (50-70 Hz). The repetition effects on hippocampal gamma synchronization occurred when pupils were most dilated, suggesting an interaction between aroused, attentive processing and hippocampal correlates of recognition memory. These results suggest that the hippocampus may support memory-guided visual search through enhanced local gamma synchrony. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  8. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  9. Quantifying and improving the efficiency of Gamma Knife treatment plans for brain metastases: results of a 1-year audit.

    Science.gov (United States)

    Wright, Gavin; Hatfield, Paul; Loughrey, Carmel; Reiner, Beatrice; Bownes, Peter

    2014-12-01

    A method for quantifying the efficiency of Gamma Knife treatment plans for metastases was previously implemented by the authors to retrospectively identify the least efficient plans and has provided insights into improved planning strategies. The aim of the current work was to ascertain whether those insights led to improved treatment plans. Following completion of the initial study, a 1-year audit of metastasis plans created at St. James's Institute of Oncology was carried out. Audited recent plans were compared with the earlier plans of the initial study, in terms of their efficiency and dosimetric quality. The statistical significance of any differences between relevant plan parameters was quantified by Mann-Whitney U-tests. Comparisons were made between all plans and repeated for a reduced set of plans from which the smallest lesions treated with a single 4-mm shot were excluded. The plan parameters compared were a plan efficiency index (PEI), the number of shots, Paddick conformity index (PCI), gradient index (GI), and percent coverage (of the lesion by the prescription isodose). A total of 157 metastatic lesions were included in the audit and were compared with 241 in the initial study. In a comparison of all cases, the audited plans achieved a higher median PEI score than did the earlier plans from the initial study (1.08 vs 1.02), indicating improved efficiency of the audited plans. When the smallest lesions (for which there was little scope for varying plan strategy) were discounted, the improvement in median PEI score was greater (1.23 vs 1.03, p planning strategy yielding these efficiency improvements did not rely on the use of significantly fewer shots (median 11 vs 11 shots, p = 0.924), nor did it result in significant detriment to dosimetric quality (median coverage 99% vs 99%, median PCI 0.84 vs 0.83, p = 0.449, and median GI 2.72 vs 2.67, p = 0.701, audited plans vs initial plans, respectively). Choice of planning strategy can substantially affect

  10. Measuring highway efficiency : A DEA approach and the Malquist index

    NARCIS (Netherlands)

    Sarmento, Joaquim Miranda; Renneboog, Luc; Verga-Matos, Pedro

    A growing concern exists regarding the efficiency of public resources spent in transport infrastructures. In this paper, we measure the efficiency of seven highway projects in Portugal over the past decade by means of a data envelopment analysis and the Malmquist productivity and efficiency indices.

  11. Numerical simulations on efficiency and measurement of capabilities of BGO detectors for high energy gamma ray

    CERN Document Server

    Wen Wan Xin

    2002-01-01

    The energy resolution and time resolution of two phi 75 x 100 BGO detectors for high energy gamma ray newly made were measured with sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co resources. The two characteristic gamma rays of high energy emitted from the thermal neutron capture of germanium in BGO crystal were used for the energy calibration of gamma spectra. The intrinsic photopeak efficiency, single escape probability and double escape probabilities of BGO detectors in photon energy range of 4-30 MeV are numerically calculated with GEANT code. The real count response and count ratio of the uniformly distributed incident photons in energy range of 0-30 MeV are also calculated. The distortion of gamma spectra caused by the photon energy loss extension to lower energy in detection medium is discussed

  12. Efficiency and effectiveness of gamma rays and sodium azide in Sesbania cannabina Poir

    International Nuclear Information System (INIS)

    Kumar, G.; Srivastava, N.

    2013-01-01

    Mutagenic effectiveness and efficiency is an important factor for the selection of a mutagen for a mutation breeding program. Mutagenic effectiveness is a measure of the frequency of mutations induced by a unit mutagen dose, while mutagenic efficiency is a measure of the proportion of mutations in relation to undesirable changes such as lethality, sterility, meiotic aberrations etc. The present study envisages the mutagenic effectiveness and efficiency of individual and combined treatments of chemical and physical mutagens i.e. sodium azide (individual), gamma rays (individual) and sodium azide + gamma ray (combined). For the individual treatment of sodium azide, the seeds of the Sesbania cannabina variety ND-1 were treated with 0.5% solution of sodium azide (SA) for four different time durations, i.e. 3, 5, 7, and 9 h, and for the individual treatment of gamma rays, dry and healthy seeds were treated with 20, 40, 60, and 80 Kr doses of gamma rays. For the combined treatment, the seeds were exposed to four different doses of gamma rays (20, 40, 60, and 80 Kr) and after irradiation seeds were treated with 0.5% solution of sodium azide for 3 h. After treatment, seeds subjected to individual and combined treatment were sown in randomized block design to raise the M 1 generation and a study was conducted on germination percentage, survival percentage, pollen fertility percentage, and chromosomal aberrations at different doses of the individual and combined treatments. (author)

  13. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry

    International Nuclear Information System (INIS)

    Chagren, S.; Tekaya, M.Ben; Reguigui, N.; Gharbi, F.

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a “virtual” reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60–2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. - Highlights: • The GEANT4 code of CERN has been used to transfer the peak efficiency from point to points and voluminous detection configurations in HPGe gamma

  14. Quantitative estimations of the efficiency of stabilization and lowering of background in gamma-spectrometry of environment samples

    International Nuclear Information System (INIS)

    Pop, O.M.; Stets, M.V.; Maslyuk, V.T.

    2015-01-01

    We consider a gamma-spectrometric complex of IEP of the NAS of Ukraine, where a passive multilayer external defense is used (complex has been made in 1989). We have developed and investigated a system of stability and lowering of background in the gamma-spectrometric complex. As metrological coefficients, the efficiency factor of defense are considered, the calculation and analysis of which show that their values are different for different energies of gamma-quanta and gamma-active nuclides

  15. Principle of some gamma cameras (efficiencies, limitations, development)

    International Nuclear Information System (INIS)

    Allemand, R.; Bourdel, J.; Gariod, R.; Laval, M.; Levy, G.; Thomas, G.

    1975-01-01

    The quality of scintigraphic images is shown to depend on the efficiency of both the input collimator and the detector. Methods are described by which the quality of these images may be improved by adaptations to either the collimator (Fresnel zone camera, Compton effect camera) or the detector (Anger camera, image amplification camera). The Anger camera and image amplification camera are at present the two main instruments whereby acceptable space and energy resolutions may be obtained. A theoretical comparative study of their efficiencies is carried out, independently of their technological differences, after which the instruments designed or under study at the LETI are presented: these include the image amplification camera, the electron amplifier tube camera using a semi-conductor target CdTe and HgI 2 detector [fr

  16. Efficiency transfer using the GEANT4 code of CERN for HPGe gamma spectrometry.

    Science.gov (United States)

    Chagren, S; Tekaya, M Ben; Reguigui, N; Gharbi, F

    2016-01-01

    In this work we apply the GEANT4 code of CERN to calculate the peak efficiency in High Pure Germanium (HPGe) gamma spectrometry using three different procedures. The first is a direct calculation. The second corresponds to the usual case of efficiency transfer between two different configurations at constant emission energy assuming a reference point detection configuration and the third, a new procedure, consists on the transfer of the peak efficiency between two detection configurations emitting the gamma ray in different energies assuming a "virtual" reference point detection configuration. No pre-optimization of the detector geometrical characteristics was performed before the transfer to test the ability of the efficiency transfer to reduce the effect of the ignorance on their real magnitude on the quality of the transferred efficiency. The obtained and measured efficiencies were found in good agreement for the two investigated methods of efficiency transfer. The obtained agreement proves that Monte Carlo method and especially the GEANT4 code constitute an efficient tool to obtain accurate detection efficiency values. The second investigated efficiency transfer procedure is useful to calibrate the HPGe gamma detector for any emission energy value for a voluminous source using one point source detection efficiency emitting in a different energy as a reference efficiency. The calculations preformed in this work were applied to the measurement exercise of the EUROMET428 project. A measurement exercise where an evaluation of the full energy peak efficiencies in the energy range 60-2000 keV for a typical coaxial p-type HpGe detector and several types of source configuration: point sources located at various distances from the detector and a cylindrical box containing three matrices was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A Versatile and Efficient GPU Data Structure for Spatial Indexing

    KAUST Repository

    Schneider, Jens

    2016-08-10

    In this paper we present a novel GPU-based data structure for spatial indexing. Based on Fenwick trees—a special type of binary indexed trees—our data structure allows construction in linear time. Updates and prefixes can be computed in logarithmic time, whereas point queries require only constant time on average. Unlike competing data structures such as summed-area tables and spatial hashing, our data structure requires a constant amount of bits for each data element, and it offers unconstrained point queries. This property makes our data structure ideally suited for applications requiring unconstrained indexing of large data, such as block-storage of large and block-sparse volumes. Finally, we provide asymptotic bounds on both run-time and memory requirements, and we show applications for which our new data structure is useful.

  18. A Versatile and Efficient GPU Data Structure for Spatial Indexing

    KAUST Repository

    Schneider, Jens; Rautek, Peter

    2016-01-01

    In this paper we present a novel GPU-based data structure for spatial indexing. Based on Fenwick trees—a special type of binary indexed trees—our data structure allows construction in linear time. Updates and prefixes can be computed in logarithmic time, whereas point queries require only constant time on average. Unlike competing data structures such as summed-area tables and spatial hashing, our data structure requires a constant amount of bits for each data element, and it offers unconstrained point queries. This property makes our data structure ideally suited for applications requiring unconstrained indexing of large data, such as block-storage of large and block-sparse volumes. Finally, we provide asymptotic bounds on both run-time and memory requirements, and we show applications for which our new data structure is useful.

  19. The Total Energy Efficiency Index for machine tools

    International Nuclear Information System (INIS)

    Schudeleit, Timo; Züst, Simon; Weiss, Lukas; Wegener, Konrad

    2016-01-01

    Energy efficiency in industries is one of the dominating challenges of the 21st century. Since the release of the eco-design directive 2005/32/EC in 2005, great research effort has been spent on the energy efficiency assessment for energy using products. The ISO (International Organization for Standardization) standardization body (ISO/TC 39 WG 12) currently works on the ISO 14955 series in order to enable the assessment of energy efficient design of machine tools. A missing piece for completion of the ISO 14955 series is a metric to quantify the design of machine tools regarding energy efficiency based on the respective assembly of components. The metric needs to take into account each machine tool components' efficiency and the need-oriented utilization in combination with the other components while referring to efficiency limits. However, a state of the art review reveals that none of the existing metrics is feasible to adequately match this goal. This paper presents a metric that matches all these criteria to promote the development of the ISO 14955 series. The applicability of the metric is proven in a practical case study on a turning machine. - Highlights: • Study for pushing forward the standardization work on the ISO 14955 series. • Review of existing energy efficiency indicators regarding three basic strategies to foster sustainability. • Development of a metric comprising the three basic strategies to foster sustainability. • Metric application for quantifying the energy efficiency of a turning machine.

  20. Efficient electron heating in relativistic shocks and gamma-ray-burst afterglow.

    Science.gov (United States)

    Gedalin, M; Balikhin, M A; Eichler, D

    2008-02-01

    Electrons in shocks are efficiently energized due to the cross-shock potential, which develops because of differential deflection of electrons and ions by the magnetic field in the shock front. The electron energization is necessarily accompanied by scattering and thermalization. The mechanism is efficient in both magnetized and nonmagnetized relativistic electron-ion shocks. It is proposed that the synchrotron emission from the heated electrons in a layer of strongly enhanced magnetic field is responsible for gamma-ray-burst afterglows.

  1. Reticuloendothelial system blocking with gamma globulins makes radioimmunotargetting more efficient

    International Nuclear Information System (INIS)

    Hazra, D.K.; Gupta, A.K.; Gangwar, P.K.; Gupta, S.; Pathak, H.; Khanna Hazra, P.; Yadava, J.P.S.

    2004-01-01

    Siemens ZLC 7500 Gamma camera, as well as by sacrifice of representative animals at timed intervals. Results: it was observed that whereas particulate india Ink was ineffective, all the high molecular weight preparations did reduce the reticutoendothelial system uptake. The most effective was human gammaglobutin and much more so when injected 24 hours prior to the radioiabetted agent. Dextran was very viscous and difficult to inject. Post injection of gammagtobulin after the radiolabelted antibodies was not effective. Conclusions: This study suggested that gammaglobutins may be useful in clinical radioimmunotherapy to enhance target/nontarget ratio. Possible extension to clinical uses of unlabelted monoclonal antibodies such as in cancers and in other indications to enhance efficacy, reduce costs and conserve scarce bi,molecules is envisaged. Acknowledgements: We are grateful to the Atomic Energy Regulatory Board for research support, and to BRIT, BARC, Mumbai for supply of isotopes, and to Prof B Bjorktund, President Swedish Cancer Council, for the gift of M3 antibody. SG received a fellowship from the Indian Council of Medical Research, India. (authors)

  2. Monitoring changes in economy-wide energy efficiency: From energy-GDP ratio to composite efficiency index

    International Nuclear Information System (INIS)

    Ang, B.W.

    2006-01-01

    Since the 1973 world oil crisis, monitoring trends in energy efficiency at the economy-wide level has been an important component of energy strategy in many countries. To support this effort, various energy efficiency-related indicators have been developed. We examine some classical indicators which are often found in national and international energy studies in the 1970s and 1980s. We then describe the recent developments in using the index decomposition analysis to give an economy-wide composite energy efficiency index based on a bottom-up approach. This composite index is superior to the classical indicators as an economy-wide energy efficiency measure and has lately been adopted by a growing number of countries for national energy efficiency trend monitoring

  3. SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, N [University of Miami, Miami, FL (United States); Denissova, S [Sylvester Comprehensive Cancer Center Deerfield, Weston, FL (United States)

    2016-06-15

    Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% to 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.

  4. Standardization of electron-capture and complex beta-gamma radionuclides by the efficiency extrapolation method

    International Nuclear Information System (INIS)

    Grigorescu, L.

    1976-07-01

    The efficiency extrapolation method was improved by establishing ''linearity conditions'' for the discrimination on the gamma channel of the coincidence equipment. These conditions were proved to eliminate the systematic error of the method. A control procedure for the fulfilment of linearity conditions and estimation of residual systematic error was given. For law-energy gamma transitions an ''equivalent scheme principle'' was established, which allow for a correct application of the method. Solutions of Cs-134, Co-57, Ba-133 and Zn-65 were standardized with an ''effective standard deviation'' of 0.3-0.7 per cent. For Zn-65 ''special linearity conditions'' were applied. (author)

  5. Efficient Outage Probability Evaluation of Diversity Receivers Over Generalized Gamma Channels

    KAUST Repository

    Ben Issaid, Chaouki; Alouini, Mohamed-Slim; Tempone, Raul

    2016-01-01

    In this paper, we are interested in determining the cumulative distribution function of the sum of generalized Gamma in the setting of rare event simulations. To this end, we present an efficient importance sampling estimator. The main result of this work is the bounded relative property of the proposed estimator. This result is used to accurately estimate the outage probability of multibranch maximum ratio combining and equal gain combining diversity receivers over generalized Gamma fading channels. Selected numerical simulations are discussed to show the robustness of our estimator compared to naive Monte Carlo.

  6. Efficiency and attenuation correction factors determination in gamma spectrometric assay of bulk samples using self radiation

    International Nuclear Information System (INIS)

    Haddad, Kh.

    2009-02-01

    Gamma spectrometry forms the most important and capable tool for measuring radioactive materials. Determination of the efficiency and attenuation correction factors is the most tedious problem in the gamma spectrometric assay of bulk samples. A new experimental and easy method for these correction factors determination using self radiation was proposed in this work. An experimental study of the correlation between self attenuation correction factor and sample thickness and its practical application was also introduced. The work was performed on NORM and uranyl nitrate bulk sample. The results of proposed methods agreed with those of traditional ones.(author)

  7. Efficient Outage Probability Evaluation of Diversity Receivers Over Generalized Gamma Channels

    KAUST Repository

    Ben Issaid, Chaouki

    2016-10-01

    In this paper, we are interested in determining the cumulative distribution function of the sum of generalized Gamma in the setting of rare event simulations. To this end, we present an efficient importance sampling estimator. The main result of this work is the bounded relative property of the proposed estimator. This result is used to accurately estimate the outage probability of multibranch maximum ratio combining and equal gain combining diversity receivers over generalized Gamma fading channels. Selected numerical simulations are discussed to show the robustness of our estimator compared to naive Monte Carlo.

  8. The efficient neutron-gamma pulse shape discrimination with small active volume scintillation detector

    International Nuclear Information System (INIS)

    Phan Van Chuan; Nguyen Duc Hoa; Nguyen Xuan Hai; Nguyen Ngoc Anh; Tuong Thi Thu Huong; Nguyen Nhi Dien; Pham Dinh Khang

    2016-01-01

    A small detector with EJ-301 liquid scintillation was manufactured for the study on the neutron-gamma pulse shape discrimination. In this research, four algorithms, including Threshold crossing time (TCT), Pulse gradient analysis (PGA), Charge comparison method (CCM), and Correlation pattern recognition (CPR) were developed and compared in terms of their discrimination effectiveness between neutrons and gamma rays. The figures of merits (FOMs) obtained for 100 ÷ 2000 keVee (keV energy electron equivalent) neutron energy range show the charge comparison method was the most efficient of the four algorithms. (author)

  9. Mutagenic effectiveness and efficiency of gamma rays and ethyl methanesulhonate in Indian mustard

    International Nuclear Information System (INIS)

    Prasad, Rajendra; Singh, Basudeo

    1986-01-01

    Mutagenic effectiveness is a measure of the frequency of mutations induced by unit dose of a mutagen while mutagenic efficiency gives the proportion of mutations in relation to other associated undesirable biological effects such as gross chromosomal aberrations, lethality and sterility induced by the mutagen in question (Konzak, et al., 1965). The usefulness of any mutagen in plant breeding depends not only on its mutagenic effectiveness but also on its mutagenic efficiency. The efficiency and effectiveness of ethyl methanesulphonate (EMS) in relation to gamma rays in Indian mustard [Brassica juncea (L.) Czern and Coss] was studied. (author)

  10. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki

    2017-01-26

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverberation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is related to the difficult question of analyzing the statistics of a sum of Gamma- Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose robust importance sampling schemes that efficiently evaluates the outage probability of diversity receivers over Gamma-Gamma fading channels. The proposed estimators satisfy the well-known bounded relative error criterion for both maximum ratio combining and equal gain combining cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  11. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki

    2016-06-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion, a well-desired property characterizing the robustness of importance sampling schemes, for both identically and non-identically independent distributed cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  12. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki; Ben Rached, Nadhir; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2016-01-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion, a well-desired property characterizing the robustness of importance sampling schemes, for both identically and non-identically independent distributed cases. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  13. A virtual dosimetry audit - Towards transferability of gamma index analysis between clinical trial QA groups.

    Science.gov (United States)

    Hussein, Mohammad; Clementel, Enrico; Eaton, David J; Greer, Peter B; Haworth, Annette; Ishikura, Satoshi; Kry, Stephen F; Lehmann, Joerg; Lye, Jessica; Monti, Angelo F; Nakamura, Mitsuhiro; Hurkmans, Coen; Clark, Catharine H

    2017-12-01

    Quality assurance (QA) for clinical trials is important. Lack of compliance can affect trial outcome. Clinical trial QA groups have different methods of dose distribution verification and analysis, all with the ultimate aim of ensuring trial compliance. The aim of this study was to gain a better understanding of different processes to inform future dosimetry audit reciprocity. Six clinical trial QA groups participated. Intensity modulated treatment plans were generated for three different cases. A range of 17 virtual 'measurements' were generated by introducing a variety of simulated perturbations (such as MLC position deviations, dose differences, gantry rotation errors, Gaussian noise) to three different treatment plan cases. Participants were blinded to the 'measured' data details. Each group analysed the datasets using their own gamma index (γ) technique and using standardised parameters for passing criteria, lower dose threshold, γ normalisation and global γ. For the same virtual 'measured' datasets, different results were observed using local techniques. For the standardised γ, differences in the percentage of points passing with γ audit has been an informative step in understanding differences in the verification of measured dose distributions between different clinical trial QA groups. This work lays the foundations for audit reciprocity between groups, particularly with more clinical trials being open to international recruitment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. More Gamma More Predictions: Gamma-Synchronization as a Key Mechanism for Efficient Integration of Classical Receptive Field Inputs with Surround Predictions

    Science.gov (United States)

    Vinck, Martin; Bosman, Conrado A.

    2016-01-01

    During visual stimulation, neurons in visual cortex often exhibit rhythmic and synchronous firing in the gamma-frequency (30–90 Hz) band. Whether this phenomenon plays a functional role during visual processing is not fully clear and remains heavily debated. In this article, we explore the function of gamma-synchronization in the context of predictive and efficient coding theories. These theories hold that sensory neurons utilize the statistical regularities in the natural world in order to improve the efficiency of the neural code, and to optimize the inference of the stimulus causes of the sensory data. In visual cortex, this relies on the integration of classical receptive field (CRF) data with predictions from the surround. Here we outline two main hypotheses about gamma-synchronization in visual cortex. First, we hypothesize that the precision of gamma-synchronization reflects the extent to which CRF data can be accurately predicted by the surround. Second, we hypothesize that different cortical columns synchronize to the extent that they accurately predict each other’s CRF visual input. We argue that these two hypotheses can account for a large number of empirical observations made on the stimulus dependencies of gamma-synchronization. Furthermore, we show that they are consistent with the known laminar dependencies of gamma-synchronization and the spatial profile of intercolumnar gamma-synchronization, as well as the dependence of gamma-synchronization on experience and development. Based on our two main hypotheses, we outline two additional hypotheses. First, we hypothesize that the precision of gamma-synchronization shows, in general, a negative dependence on RF size. In support, we review evidence showing that gamma-synchronization decreases in strength along the visual hierarchy, and tends to be more prominent in species with small V1 RFs. Second, we hypothesize that gamma-synchronized network dynamics facilitate the emergence of spiking output that

  15. Study on the Effects of Sample Density on Gamma Spectrometry System Measurement Efficiency at Radiochemistry and Environment Laboratory

    International Nuclear Information System (INIS)

    Wo, Y.M.; Dainee Nor Fardzila Ahmad Tugi; Khairul Nizam Razali

    2015-01-01

    The effects of sample density on the measurement efficiency of the gamma spectrometry system were studied by using four sets multi nuclide standard sources of various densities between 0.3 - 1.4 g/ ml. The study was conducted on seven unit 25 % coaxial HPGe detector gamma spectrometry systems in Radiochemistry and Environment Laboratory (RAS). Difference on efficiency against gamma emitting radionuclides energy and measurement systems were compared and discussed. Correction factor for self absorption caused by difference in sample matrix density of the gamma systems were estimated. The correction factors are to be used in quantification of radionuclides concentration in various densities of service and research samples in RAS. (author)

  16. Mutagenic effectiveness and efficiency of EMS, sodium azide and gamma radiation in chickpea (Cicer arietinum L.)

    International Nuclear Information System (INIS)

    Barshile, J.D.; Apparao, B.J.

    2006-01-01

    Mutagenic effectiveness and efficiency of Ethyl Methane Sulphonate (EMS), Sodium Azide (SA) and gamma radiation on two cultivars of chickpea (Cicer arietinum L), Vijay and Vishwas were evaluated by the biological damages caused by them in M 1 generation and on the basis of frequency of chlorophyll mutations produced in the M 2 generation. All mutagenic treatments of EMS, SA and gamma radiation decreased germination, seedling height, plant survival and pollen fertility in both the cultivars. The extent of effect was dose dependent. LD 50 values of mutagen were found to be helpful for planning experimental mutagenesis in chickpea. Frequency of chlorophyll mutations in M 2 generation was less in Vijay as compared to Vishwas. Mutagenic effectiveness is inversely proportional to the increasing concentrations/doses of mutagens in both the cultivars, except for gamma radiation treatments in the cultivar Vishwas. All three mutagens (except EMS in the Vijay and gamma radiation in the cultivar Vishwas) exhibited gradual decrease in mutagenic efficiency, with an increase in their concentration/dose. (author)

  17. Toward advanced gamma rays radiation resistance and shielding efficiency with phthalonitrile resins and composites

    Science.gov (United States)

    Derradji, Mehdi; Zegaoui, Abdeldjalil; Xu, Yi-Le; Wang, An-ran; Dayo, Abdul Qadeer; Wang, Jun; Liu, Wen-bin; Liu, Yu-Guang; Khiari, Karim

    2018-04-01

    The phthalonitrile resins have claimed the leading place in the field of high performance polymers thanks to their combination of outstanding properties. The present work explores for the first time the gamma rays radiation resistance and shielding efficiency of the phthalonitrile resins and its related tungsten-reinforced nanocomposites. The primary goal of this research is to define the basic behavior of the phthalonitrile resins under highly ionizing gamma rays. The obtained results confirmed that the neat phthalonitrile resins can resist absorbed doses as high as 200 kGy. Meanwhile, the remarkable shielding efficiency of the phthalonitrile polymers was confirmed to be easily improved by preparing lead-free nanocomposites. In fact, the gamma rays screening ratio reached the exceptional value of 42% for the nanocomposites of 50 wt% of nano-tungsten loading. Thus, this study confirms that the remarkable performances of the phthalonitrile resins are not limited to the thermal and mechanical properties and can be extended to the gamma rays radiation and shielding resistances.

  18. An efficient link prediction index for complex military organization

    Science.gov (United States)

    Fan, Changjun; Liu, Zhong; Lu, Xin; Xiu, Baoxin; Chen, Qing

    2017-03-01

    Quality of information is crucial for decision-makers to judge the battlefield situations and design the best operation plans, however, real intelligence data are often incomplete and noisy, where missing links prediction methods and spurious links identification algorithms can be applied, if modeling the complex military organization as the complex network where nodes represent functional units and edges denote communication links. Traditional link prediction methods usually work well on homogeneous networks, but few for the heterogeneous ones. And the military network is a typical heterogeneous network, where there are different types of nodes and edges. In this paper, we proposed a combined link prediction index considering both the nodes' types effects and nodes' structural similarities, and demonstrated that it is remarkably superior to all the 25 existing similarity-based methods both in predicting missing links and identifying spurious links in a real military network data; we also investigated the algorithms' robustness under noisy environment, and found the mistaken information is more misleading than incomplete information in military areas, which is different from that in recommendation systems, and our method maintained the best performance under the condition of small noise. Since the real military network intelligence must be carefully checked at first due to its significance, and link prediction methods are just adopted to purify the network with the left latent noise, the method proposed here is applicable in real situations. In the end, as the FINC-E model, here used to describe the complex military organizations, is also suitable to many other social organizations, such as criminal networks, business organizations, etc., thus our method has its prospects in these areas for many tasks, like detecting the underground relationships between terrorists, predicting the potential business markets for decision-makers, and so on.

  19. Evaluation of Different Score Index for Predicting Prognosis in Gamma Knife Radiosurgical Treatment for Brain Metastasis

    International Nuclear Information System (INIS)

    Franzin, Alberto; Snider, Silvia; Picozzi, Piero; Bolognesi, Angelo; Serra, Carlo; Vimercati, Alberto; Passarin, Olga; Mortini, Pietro

    2009-01-01

    Purpose: To assess the utility of the Radiation Therapy Oncology Group Recursive Partitioning Analysis (RPA) and Score Index for Radiosurgery (SIR) stratification systems in predicting survival in patients with brain metastasis treated with Gamma Knife radiosurgery (GKRS). Methods and Materials: A total of 185 patients were included in the study. Patients were stratified according to RPA and SIR classes. The RPA and SIR classes, age, Karnofsky Performance Status (KPS), and systemic disease were correlated with survival. Results: Five patients were lost to follow-up. Median survival in patients in RPA Class 1 (30 patients) was 17 months; in Class 2 (140 patients), 10 months; and in Class 3 (10 patients), 3 months. Median survival in patients in SIR Class 1 (30 patients) was 3 months; in Class 2 (135 patients), 8 months; and in Class 3 (15 patients), 20 months. In univariate testing, age younger than 65 years (p = 0.0004), KPS higher than 70 (p = 0.0001), RPA class (p = 0.0078), SIR class (p = 0.0002), and control of the primary tumor (p = 0.02) were significantly associated with improved outcome. In multivariate analysis, KPS (p < 0.0001), SIR class (p = 0.0008), and RPA class (p = 0.03) had statistical value. Conclusions: This study supports the use of GKRS as a single-treatment modality in this selected group of patients. Stratification systems are useful in the estimation of patient eligibility for GKRS. A second-line treatment was necessary in 30% of patients to achieve distal or local brain control. This strategy is useful to control brain metastasis in long-surviving patients.

  20. Full energy peak efficiency of composite detectors for high energy gamma-rays

    International Nuclear Information System (INIS)

    Kshetri, Ritesh

    2015-01-01

    Experiments involving radioactive beams demand high detection efficiencies. One of the ways to obtain high detection efficiency without deteriorating the energy resolution or timing characteristics is the use of composite detectors which are composed of standard HPGe crystals arranged in a compact way. Two simplest composite detectors are the clover and cluster detectors. The TRIUMF-ISAC Gamma-Ray Escape-Suppressed Spectrometer (TIGRESS) comprises of 16 large volume, 32-fold segmented HPGe clover detectors, where each detector is shielded by a 20-fold segmented escape suppression shield (ESS)

  1. Gamma-ray spectrometer system with high efficiency and high resolution

    International Nuclear Information System (INIS)

    Moss, C.E.; Bernard, W.; Dowdy, E.J.; Garcia, C.; Lucas, M.C.; Pratt, J.C.

    1983-01-01

    Our gamma-ray spectrometer system, designed for field use, offers high efficiency and high resolution for safeguards applications. The system consists of three 40% high-purity germanium detectors and a LeCroy 3500 data acquisition system that calculates a composite spectrum for the three detectors. The LeCroy 3500 mainframe can be operated remotely from the detector array with control exercised through modems and the telephone system. System performance with a mixed source of 125 Sb, 154 Eu, and 155 Eu confirms the expected efficiency of 120% with the overall resolution showing little degradation over that of the worst detector

  2. The Effect of Gamma Irradiation on Yellowness Index (Y I) and Mechanical Properties in Plastic Food Packaging

    International Nuclear Information System (INIS)

    Tanhindarto, Rindy P.; I, Dian

    2002-01-01

    An experiment has been done for measuring the yellowness index (Yi) and mechanical properties at food packaging material was caused by gamma irradiation. The samples were obtained from the manufacture. There were three of samples with types of poly acrylonitrile copolymer, PVdC laminated biaxially oriented polypropylene and poly vinyl chloride films. Samples were irradiated at ambient temperature by gamma rays with the doses of 0 up to 100 kGy. Yellowness Index (Yi) of sample was carried out by using chromameter Hunter Lab system. while mechanical properties measuring by stragraph. The purpose of the present experiment was the yellowness index (Yi) and mechanical properties of food packaging material after and before the irradiation. The effects of I year storage on irradiated and unirradiated samples were also investigated. The results showed that best of three samples of plastic food packaging was poly acrylonitrile copolymer film because the Yellowness Index (Yi) and mechanical properties of poly acrylonitrile copolymer did not give any measurable change on the plastic treated by irradiation up to 100 kGy. Storage for 1 year gave some measurable changes of e Yellowness Index (Yi) and mechanical properties on all the samples examined

  3. Efficient Indexing of the Historical, Present, and Future Positions of Moving Objects

    DEFF Research Database (Denmark)

    Lin, D.; Jensen, Christian Søndergaard; Ooi, B.C.

    2005-01-01

    Although significant effort has been put into the development of efficient spatio-temporal indexing techniques for moving objects, little attention has been given to the development of techniques that efficiently support queries about the past, present, and future positions of objects...... time. The index stores linearized moving-object locations in a forest of B+-trees. The index supports queries that select objects based on temporal and spatial constraints, such as queries that retrieve all objects whose positions fall within a spatial range during a set of time intervals. Empirical...

  4. The use of energy analysis and indexes of energy efficiency in nuclear power

    International Nuclear Information System (INIS)

    D'yakonov, E.I.; Ignatenko, E.I.

    1991-01-01

    The results of calculating the indexes of energy efficiency for NPPs with the WWER-1000 and RBMK-1000 reactors, heat and power NPPs with the WWER-1000 and dictrict heating NPPs with the AST-500 reactor in three fuel cycles, namely, the open one and with uranium and plutonium recycles, are considered. Complex account for the quantity and quality of produced and consumed energy provides for objective evaluation of the indexes of energy efficiency during comparative analysis of nuclear power plants with different types of reactors. It is shown that complex use of the energy produced at a NPP provides for increase of indexes of energy efficiency. The highest indexes are obtained for heat and power NPP with the WWER-1000 reactor in the open fuel cycle, with uranium and plutonium recycle and for NPP with the WWER-1000 reactor with plutonium recycle

  5. Methods for fitting of efficiency curves obtained by means of HPGe gamma rays spectrometers

    International Nuclear Information System (INIS)

    Cardoso, Vanderlei

    2002-01-01

    The present work describes a few methodologies developed for fitting efficiency curves obtained by means of a HPGe gamma-ray spectrometer. The interpolated values were determined by simple polynomial fitting and polynomial fitting between the ratio of experimental peak efficiency and total efficiency, calculated by Monte Carlo technique, as a function of gamma-ray energy. Moreover, non-linear fitting has been performed using a segmented polynomial function and applying the Gauss-Marquardt method. For the peak area obtainment different methodologies were developed in order to estimate the background area under the peak. This information was obtained by numerical integration or by using analytical functions associated to the background. One non-calibrated radioactive source has been included in the curve efficiency in order to provide additional calibration points. As a by-product, it was possible to determine the activity of this non-calibrated source. For all fittings developed in the present work the covariance matrix methodology was used, which is an essential procedure in order to give a complete description of the partial uncertainties involved. (author)

  6. Selection of methanogenic microbial by gamma irradiation on improvement of unaerobic digestion efficiency on biogas formation

    International Nuclear Information System (INIS)

    M Yazid; Aris Bastianudin

    2011-01-01

    Selection of methanogenic microbial by gamma irradiation as an effort on improvement of efficiency process on biogas formation has been done. The objectives of this research is to obtain the methanogenic microbial isolate with high specific growth constant (μ), there for will be applicable for increasing the efficiency of biogas formation process. The microbial content sludge sample was taken from the digester tank conventional biogas installation located in Marangan village, Bokoharjo, Prambanan, Sleman and the sludge was irradiated using Co-60 gamma irradiator with varied dosage dose of 0-25 KGy. Microbial culture formation is conducted in growing media with 30% liquid rumen content in un-aerobe condition by addition of 80% H2 and 20% CO_2 gas mixture. Analysis of colony growth was performed by observation using long-wave ultraviolet rays (UV rays), while the microbial growth was by spectro-photometric analysis. Determination of gas methane product was done using gas chromatographic method. The result shown that 4 isolated methanogenic microbial (RB10, RB15, RB20 and RB25) that grown on 10-25 kGy gamma irradiation. The identification result shows that isolate RB10 and RB25 are belong to Methanobacterium genus, while isolate RB15 and RB20 are belong to Methanosarcina and Methanospirillum genus respectively. The specific growth constant (μ) values of the 4 bacterial isolates are in the range between 0.022 - 0.031. On the other hand, the efficiency of methane gas production for each isolates is in the range of 53.4%. - 67.6%. It can be concluded that isolate RB25 was the isolate with the highest specific growth constant (μ) value 0.031 and its efficiency of methane gas production was 67.6%. (author)

  7. Efficient approximation of the incomplete gamma function for use in cloud model applications

    Directory of Open Access Journals (Sweden)

    U. Blahak

    2010-07-01

    Full Text Available This paper describes an approximation to the lower incomplete gamma function γl(a,x which has been obtained by nonlinear curve fitting. It comprises a fixed number of terms and yields moderate accuracy (the absolute approximation error of the corresponding normalized incomplete gamma function P is smaller than 0.02 in the range 0.9 ≤ a ≤ 45 and x≥0. Monotonicity and asymptotic behaviour of the original incomplete gamma function is preserved.

    While providing a slight to moderate performance gain on scalar machines (depending on whether a stays the same for subsequent function evaluations or not compared to established and more accurate methods based on series- or continued fraction expansions with a variable number of terms, a big advantage over these more accurate methods is the applicability on vector CPUs. Here the fixed number of terms enables proper and efficient vectorization. The fixed number of terms might be also beneficial on massively parallel machines to avoid load imbalances, caused by a possibly vastly different number of terms in series expansions to reach convergence at different grid points. For many cloud microphysical applications, the provided moderate accuracy should be enough. However, on scalar machines and if a is the same for subsequent function evaluations, the most efficient method to evaluate incomplete gamma functions is perhaps interpolation of pre-computed regular lookup tables (most simple example: equidistant tables.

  8. Thin film CdTe based neutron detectors with high thermal neutron efficiency and gamma rejection for security applications

    Energy Technology Data Exchange (ETDEWEB)

    Smith, L.; Murphy, J.W. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Kim, J. [Korean Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of); Rozhdestvenskyy, S.; Mejia, I. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Park, H. [Korean Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of); Allee, D.R. [Flexible Display Center, Arizona State University, Phoenix, AZ 85284 (United States); Quevedo-Lopez, M. [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States); Gnade, B., E-mail: beg031000@utdallas.edu [Materials Science and Engineering, University of Texas at Dallas, Richardson, TX 75080 (United States)

    2016-12-01

    Solid-state neutron detectors offer an alternative to {sup 3}He based detectors, but suffer from limited neutron efficiencies that make their use in security applications impractical. Solid-state neutron detectors based on single crystal silicon also have relatively high gamma-ray efficiencies that lead to false positives. Thin film polycrystalline CdTe based detectors require less complex processing with significantly lower gamma-ray efficiencies. Advanced geometries can also be implemented to achieve high thermal neutron efficiencies competitive with silicon based technology. This study evaluates these strategies by simulation and experimentation and demonstrates an approach to achieve >10% intrinsic efficiency with <10{sup −6} gamma-ray efficiency.

  9. Development of the fast and efficient gamma detector using Cherenkov light for TOF-PET

    Science.gov (United States)

    Canot, C.; Alokhina, M.; Abbon, P.; Bard, J. P.; Tauzin, G.; Yvon, D.; Sharyy, V.

    2017-12-01

    In this paper we present two configurations of innovative gamma detectors using Cherenkov light for time-of-flight—Positron Emission Tomography (PET). The first uses heavy crystals as a Cherenkov radiator to develop a demonstrator for a whole body PET scanner with high detection efficiency. We demonstrated a 30% detection efficiency and a 180 ps (FWHM) time resolution, mainly limited by the time transit spread of the photomultiplier. The second configuration uses an innovative liquid, the TriMethyl Bismuth, to develop a high precision brain-scanning PET device with time-of-flight capability. According to Geant4 simulation, we expect to reach a precision of 150 ps (FWHM) and an efficiency of about 25%.

  10. The German 2020 Energy Turnaround Index featuring a special focus on economic efficiency; Energiewende-Index Deutschland 2020. Fokusthema Wirtschaftlichkeit

    Energy Technology Data Exchange (ETDEWEB)

    Vahlenkamp, Thomas [McKinsey and Company, Duesseldorf (Germany); Gohl, Matthias [McKinsey and Company, Berlin (Germany)

    2012-12-15

    The decision to raise the levy imposed by the Renewable Energies Law has kindled the discussion as to how the energy turnaround can best be implemented and made affordable in the first place. The search for solutions should be founded on as full a picture of the situation as possible as well as a fact base shared by all. The aspiration and purpose of the German 2020 Energy Turnaround Index created by McKinsey and Company is to create precisely such a fact base. Every 3 months the index gives an update on the status of the energy turnaround based on 15 indicators. The present update additionally takes a closer look at the aspect of economic efficiency, which together with climate and environment protection and security of supply forms the triad of imperatives driving the energy turnaround.

  11. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  12. Detection efficiency for radionuclides decaying by electron capture and gamma-Ray

    International Nuclear Information System (INIS)

    Grau, A.; Fernandez, A.

    1985-01-01

    In this paper, the electron capture partial counting efficiency vs the figure of merit for electron-capture and gamma-ray emitters has been computed. The radionuclides tabulated are 48 c r, 54 M n, 57 C o 56 N i, 72 S e, 73 A s, 85 S r, 88 Z r, 92 N b, 103 P d, 111 l n, 119 S b, 125 I , 139 C e and 152 D y. It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 15 cm 3 . (Author) 17 refs

  13. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  14. Highly accurate determination of relative gamma-ray detection efficiency for Ge detector and its application

    International Nuclear Information System (INIS)

    Miyahara, H.; Mori, C.; Fleming, R.F.; Dewaraja, Y.K.

    1997-01-01

    When quantitative measurements of γ-rays using High-Purity Ge (HPGe) detectors are made for a variety of applications, accurate knowledge of oy-ray detection efficiency is required. The emission rates of γ-rays from sources can be determined quickly in the case that the absolute peak efficiency is calibrated. On the other hand, the relative peak efficiencies can be used for determination of intensity ratios for plural samples and for comparison to the standard source. Thus, both absolute and relative detection efficiencies are important in use of γ-ray detector. The objective of this work is to determine the relative gamma-ray peak detection efficiency for an HPGe detector with the uncertainty approaching 0.1% . We used some nuclides which emit at least two gamma-rays with energies from 700 to 2400 keV for which the relative emission probabilities are known with uncertainties much smaller than 0.1%. The relative peak detection efficiencies were calculated from the measurements of the nuclides, 46 Sc, 48 Sc, 60 Co and 94 Nb, emitting two γ- rays with the emission probabilities of almost unity. It is important that various corrections for the emission probabilities, the cascade summing effect, and the self-absorption are small. A third order polynomial function on both logarithmic scales of energy and efficiency was fitted to the data, and the peak efficiency predicted at certain energy from covariance matrix showed the uncertainty less than 0.5% except for near 700 keV. As an application, the emission probabilities of the 1037.5 and 1212.9 keV γ-rays for 48 Sc were determined using the function of the highly precise relative peak efficiency. Those were 0.9777+0,.00079 and 0.02345+0.00017 for the 1037.5 and 1212.9 keV γ-rays, respectively. The sum of these probabilities is close to unity within the uncertainty which means that the certainties of the results are high and the accuracy has been improved considerably

  15. Numerical Simulations of Pillar Structured Solid State Thermal Neutron Detector Efficiency and Gamma Discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Conway, A; Wang, T; Deo, N; Cheung, C; Nikolic, R

    2008-06-24

    This work reports numerical simulations of a novel three-dimensionally integrated, {sup 10}boron ({sup 10}B) and silicon p+, intrinsic, n+ (PIN) diode micropillar array for thermal neutron detection. The inter-digitated device structure has a high probability of interaction between the Si PIN pillars and the charged particles (alpha and {sup 7}Li) created from the neutron - {sup 10}B reaction. In this work, the effect of both the 3-D geometry (including pillar diameter, separation and height) and energy loss mechanisms are investigated via simulations to predict the neutron detection efficiency and gamma discrimination of this structure. The simulation results are demonstrated to compare well with the measurement results. This indicates that upon scaling the pillar height, a high efficiency thermal neutron detector is possible.

  16. Disinfection of secondary effluent by gamma radiation inactivation efficiency and regrowth

    International Nuclear Information System (INIS)

    Sekiguchi, M.; Sawai, T.; Shimokawa, T.; Sawai, T.

    1992-01-01

    Inactivation efficiencies of several microorganisms in secondary effluents (SE) from sewage treatment plants by gamma radiation were investigated. Escherichia coli, Klebsiella pneumoniae and Enterobacter cloacae inoculated in SE were very sensitive but Streptcoccus sp. was resistant to gamma radiation. In addition, no significant difference was found between the combined sewer system and the separate sewer system in regards to the inactivation efficiencies of the bacteria inoculated in the SE. The number of total bacteria in SE was rapidly decreased in the dose range of 0 to 0.2-0.3 kGy but the number gradually fell over the dose range. Moreover, the number of total coliforms almost exponentially decreased with increasing dose, and fell to undetectable levels at about 0.5 kGy. Because of the decrease of the initial bacteria number in SE, adequate filtrating treatments were effective in lowering the irradiation dose for disinfection. Further, the effects of filtrating treatment on bacteria regrowth in SE are discussed. (author)

  17. A comment on the calculation of the total-factor energy efficiency (TFEE) index

    International Nuclear Information System (INIS)

    Chang, Ming-Chung

    2013-01-01

    This study provides a no-output growth model to conveniently calculate the total-factor energy efficiency (TFEE) index originally proposed by Hu and Wang (2006). The TFEE index serves as a very well-known and popular means of estimating overall energy efficiency. While many previous studies have used the indicator of energy inefficiency, including the indicator of energy intensity (i.e., Energy input/Gross Domestic Product (GDP)) to measure energy efficiency, Hu and Kao (2007) point out that the indicator of energy intensity is not only a partial-factor energy efficiency indicator, but that this partial-factor ratio is also quite inappropriate for analyzing the impact of changing energy use over time. The TFEE index overcomes the disadvantage of the indicator of energy intensity as mentioned above, but five steps are needed to calculate the TFEE score. In this study, we provide a no-output growth model to conveniently calculate the TFEE score. Furthermore, we extend this no-output growth model to an output growth model. This study concludes that the output growth model not only makes it easier to calculate the TFEE index than the model proposed by Hu and Wang (2006) and Hu and Kao (2007), but that it can also obtain better TFEE scores. - Highlights: ► The comment is on the total-factor energy efficiency (TFEE) index. ► Two extension models are no-output growth model and output growth model. ► The model in this study makes it easier to calculate the TFEE index.

  18. An efficient modularized sample-based method to estimate the first-order Sobol' index

    International Nuclear Information System (INIS)

    Li, Chenzhao; Mahadevan, Sankaran

    2016-01-01

    Sobol' index is a prominent methodology in global sensitivity analysis. This paper aims to directly estimate the Sobol' index based only on available input–output samples, even if the underlying model is unavailable. For this purpose, a new method to calculate the first-order Sobol' index is proposed. The innovation is that the conditional variance and mean in the formula of the first-order index are calculated at an unknown but existing location of model inputs, instead of an explicit user-defined location. The proposed method is modularized in two aspects: 1) index calculations for different model inputs are separate and use the same set of samples; and 2) model input sampling, model evaluation, and index calculation are separate. Due to this modularization, the proposed method is capable to compute the first-order index if only input–output samples are available but the underlying model is unavailable, and its computational cost is not proportional to the dimension of the model inputs. In addition, the proposed method can also estimate the first-order index with correlated model inputs. Considering that the first-order index is a desired metric to rank model inputs but current methods can only handle independent model inputs, the proposed method contributes to fill this gap. - Highlights: • An efficient method to estimate the first-order Sobol' index. • Estimate the index from input–output samples directly. • Computational cost is not proportional to the number of model inputs. • Handle both uncorrelated and correlated model inputs.

  19. Effect of refraction index and thickness of the light guide in the position-sensitive gamma-ray detector using compact PS-PMTs

    International Nuclear Information System (INIS)

    Inoue, K.; Saito, H.; Nagashima, Y.; Hyodo, T.; Nagai, Y.; Muramatsu, S.; Nagai, S.

    2000-01-01

    We constructed a position-sensitive gamma-ray detector consisting of an array of BGO scintillators, a light guide and compact PS-PMTs. The effects of refractive index and thickness of the light guide of a glass plate on the detector performance were investigated. A light guide with higher refractive index and smaller thickness is found better for a good spatial resolution.

  20. Finance-economical indexes of efficiency of development of railway transport

    Directory of Open Access Journals (Sweden)

    M. Chekhovska

    2012-12-01

    Full Text Available Because of formation of public joint-stock company of railway transport of the common use, by an author it is suggested to carry out the analysis of efficiency of subsequent development of railway transport, leaning against indexes which represent the finance-economical constituent of results of activity of corporate enterprises.

  1. Policy efficiency in the field of food sustainability. The adjusted food agriculture and nutrition index.

    Science.gov (United States)

    Agovino, Massimiliano; Cerciello, Massimiliano; Gatto, Andrea

    2018-07-15

    This work introduces a revised version of the Food Sustainability Index, proposed by the Economist Intelligence Unit and the Barilla Center for Food and Nutrition in 2016. Our Adjusted Food Sustainability Index features two important advantages: 1) it employs the Mazziotta-Pareto method to compute weights, hence granting an objective aggregation criterion and 2) it does not take policy variables into account, thus focusing on the status quo. The policy variables are aggregated into the Policy Index, measuring the quality of the food sustainability policies. We compute the two indices for 25 countries worldwide, then we use the Data Envelopment Analysis to evaluate policy efficiency. Our results show that country-level variation in policy efficiency is wide and policies affect food sustainability significantly, especially when they target nutritional challenges. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Theta–gamma coordination between anterior cingulate and prefrontal cortex indexes correct attention shifts

    Science.gov (United States)

    Voloh, Benjamin; Valiante, Taufik A.; Everling, Stefan; Womelsdorf, Thilo

    2015-01-01

    Anterior cingulate and lateral prefrontal cortex (ACC/PFC) are believed to coordinate activity to flexibly prioritize the processing of goal-relevant over irrelevant information. This between-area coordination may be realized by common low-frequency excitability changes synchronizing segregated high-frequency activations. We tested this coordination hypothesis by recording in macaque ACC/PFC during the covert utilization of attention cues. We found robust increases of 5–10 Hz (theta) to 35–55 Hz (gamma) phase–amplitude correlation between ACC and PFC during successful attention shifts but not before errors. Cortical sites providing theta phases (i) showed a prominent cue-induced phase reset, (ii) were more likely in ACC than PFC, and (iii) hosted neurons with burst firing events that synchronized to distant gamma activity. These findings suggest that interareal theta–gamma correlations could follow mechanistically from a cue-triggered reactivation of rule memory that synchronizes theta across ACC/PFC. PMID:26100868

  3. Efficiency evaluation of customer satisfaction index in e-banking using the fuzzy data envelopment analysis

    Directory of Open Access Journals (Sweden)

    Aliyar Esmaeili

    2014-01-01

    Full Text Available E-commerce has created significant opportunities for the corporations to understand the customers’ expectations, desired values, to increase their satisfaction and to expand their market share, more efficiently. The most significant activity of e-commerce is in the field of e-banking and financial services. Customer satisfaction index is a concept introduced for evaluating of the service quality in electronic banking. Considering the relative importance of customer satisfaction in e-banking, defining scientific criteria for the assessment of mentioned index is very important. So, a scientific and efficient method is always needed. The purpose of this paper is to use the fuzzy data envelopment analysis (DEA techniques for evaluating and ranking the efficiency of online customer satisfaction index in eight economic banks in Iran. Here, we first study the fuzzy set theory and the method of traditional DEA in the same model. Next, the relationship between them were developed, which provide the fuzzy DEA model with qualitative data. The SPSS and GAMS software package were employed to analyze the data collected through questionnaires. The results show that three economic banks in terms of customer satisfaction in e-banking were located on the efficiency border and were quite efficient.

  4. Maximizing Efficiency and Reducing Robotic Surgery Costs Using the NASA Task Load Index.

    Science.gov (United States)

    Walters, Carrie; Webb, Paula J

    2017-10-01

    Perioperative leaders at our facility were struggling to meet efficiency targets for robotic surgery procedures while also maintaining the satisfaction of the surgical team. We developed a human resources time and motion study tool and used it in conjunction with the NASA Task Load Index to observe and analyze the required workload of personnel assigned to 25 robotic surgery procedures. The time and motion study identified opportunities to enlist the help of nonlicensed support personnel to ensure safe patient care and improve OR efficiency. Using the NASA Task Load Index demonstrated that high temporal, effort, and physical demands existed for personnel assisting with and performing robotic surgery. We believe that this process could be used to develop cost-effective staffing models, resulting in safe and efficient care for all surgical patients. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  5. Gamma ray, EMS and sodium azide induced effectiveness and efficiency of chlorophyll mutations in basmati rice (Oryza sativa L.)

    International Nuclear Information System (INIS)

    Singh, Sanjeev; Singh, J.; Singh, R.K.

    2001-01-01

    The effectiveness and efficiency of gamma ray, EMS, sodium azide alone or in combination in relation to chlorophyll mutations in two varieties of Basmati rice (Oryza sativa L.) in M 2 generation were studied. The chlorophyll mutations were induced by all the doses of mutagens alone or in combination relatively at a fair frequency in both the varieties in M 2 generation. In general, it was found that combination treatments of gamma rays and EMS were observed to be more efficient in Taraori Basmati, while EMS alone and combination treatment of gamma rays and EMS were more efficient in Pusa Basmati 1 on sterility and growth injury basis both. Sodium azide at 0.5 mM was found as the most effective dose in both Taraori Basmati and Pusa Basmati 1 cultivars. (author)

  6. Management Index Systems and Energy Efficiency Diagnosis Model for Power Plant: Cases in China

    Directory of Open Access Journals (Sweden)

    Jing-Min Wang

    2016-01-01

    Full Text Available In recent years, the energy efficiency of thermal power plant largely contributes to that of the industry. A thorough understanding of influencing factors, as well as the establishment of scientific and comprehensive diagnosis model, plays a key role in the operational efficiency and competitiveness for the thermal power plant. Referring to domestic and abroad researches towards energy efficiency management, based on Cloud model and data envelopment analysis (DEA model, a qualitative and quantitative index system and a comprehensive diagnostic model (CDM are construed. To testify rationality and usability of CDM, case studies of large-scaled Chinese thermal power plants have been conducted. In this case, CDM excavates such qualitative factors as technology, management, and so forth. The results shows that, compared with conventional model, which only considered production running parameters, the CDM bears better adaption to reality. It can provide entities with efficient instruments for energy efficiency diagnosis.

  7. Provincial human development index, a guide for efficiency level analysis: the case of iran.

    Science.gov (United States)

    Sabermahani, Asma; Barouni, Mohsen; Seyedin, Hesam; Aryankhesal, Aidin

    2013-01-01

    Human Development Index (HDI) is a composite indicator that can show the impact of economic strategies on human life standards. The index is calculated by three main factors of income, education and health. This research studies the status of HDI across the Iranian provinces, its changes over time and the efficiency of provinces in using resources. The data for 2001 and 2009 was obtained from the Iranian Center of Statistics. Data envelopment analysis technique was used to analyze the data. To calculate the efficiency, Banker, Charnes and Cooper's model was used. The national mean for the HDI in 2001 was 0.717 while it grew to 0.747 in 2009. Except for one province, all others had an improved human development index. Low ranked provinces such as Sistan & Baluchistan and Kurdistan stayed at the bottom in 2009 as well. Some provinces such as Bushehr with developing oil industries, or those purposively benefited from national oil income showed good growth. In some provinces, such as Hormozgan, out-migration of manpower to its neighboring province, Bushehr, was associated with decrease of the provincial income level. The number of efficient provinces increased from 5 to 13 in 2009. Iran falls among countries with high human development index based on the 2009 data. However, the distribution of HDI status across provinces was highly varied and the difference between high- and low-developed provinces increased in 2009. The government needs to revise policies concerning distribution of resources among the provinces.

  8. The efficiency of gamma irradiation on the bacterium pseudomonas fluorescence (Migh) against the mediterranean fruit fly ceratitis capitata (wiedemann)

    International Nuclear Information System (INIS)

    Fadel, A.M.

    2002-01-01

    The efficiency of the bacterium pseudomonas fluorescence against the mediterranean fruit fly ceratitis capitata (Wied.) was investigated. Adult emergence was significantly reduced by applying the wild and gamma irradiated strain (150 and 300 Gy). The highest reduction occurred by the mutant P1 and the highest concentration (10 8 ). The activity of this bacteria increased by gamma irradiation compared to that of the wild isolate. The reduction in adult survival of both males and females was highly significant by applying the irradiated bacteria with the two doses of gamma radiation and different concentration (10 8 , 10 6 and 10 4 ) of bacterial suspension. Applying the bacteria as a culture filtrate reduced adult survival of wild strain significantly, while the irradiated strain recorded a significant reduction in males and females with the highest concentration (100 %) and by applying the two doses of gamma radiation (150 and 300 Gy) and in females only at the concentration 50% by using the dose of 150 Gy

  9. Efficiency versus Maqashid Sharia Index: an Application on Indonesian Islamic Bank

    Directory of Open Access Journals (Sweden)

    Aam S. Rusydiana

    2017-09-01

    Full Text Available The Development of Islamic Banking Industry in Indonesia relatively shows a good tendency. In the market, inefficiency would be the great obstacles in head to head to conventional bank. Despite of efficiency performance in Islamic Bank, Islamic Bank also must have sharia compliance performance. So it needed to identified the efficiency of Islamic Bank in Indonesia and the achievement of Maslahah in term of three aspects, there are education, the creating of justice, and the attainment of welfare. This study would try to measure the efficiency of Islamic Banking Industry with Data Envelopment Analysis (DEA method and also to evaluate the performance by using Maqasid Sharia Index (MSI. Banxia Frontier Analyst 3.1 used in the data calculation. The calculation of the level of Islamic Bank efficiency in this study are relative, not absolute. Result of this study indicate four main findings, first, Islamic bank involve in quadran 1 is Islamic bank who reached the highest efficiency and the best performance; there are BMI and Bank Panin Sharia. Islamic bank involve in quadran 2 is Islamic bank who reached the highest efficiency and the lowest performance, there are BSM, Maybank Sharia, and Bank Sharia Bukopin. Islamic bank involve in quadran 3 is Islamic bank who reached the lowest efficiency and have a good performance, there are BRI sharia, and BCA sharia. Islamic bank involve in quadran 4 is Islamic bank who reached the lowest efficiency and the lowest performance, there are Bank Mega Sharia, Victoria Sharia, BNI Sharia, and BJB Sharia.

  10. Efficient approximations of dispersion relations in optical waveguides with varying refractive-index profiles.

    Science.gov (United States)

    Li, Yutian; Zhu, Jianxin

    2015-05-04

    In this paper we consider the problem of computing the eigen-modes for the varying refractive-index profile in an open waveguide. We first approximate the refractive-index by a piecewise polynomial of degree two, and the corresponding Sturm-Liouville problem (eigenvalue problem) of the Helmholtz operator in each layer can be solved analytically by the Kummer functions. Then, analytical approximate dispersion equations are established for both TE and TM cases. Furthermore, the approximate dispersion equations converge fast to the exact ones for the continuous refractive-index function as the maximum value of the subinterval sizes tends to zero. Suitable numerical methods, such as Müller's method or the chord secant method, may be applied to the dispersion relations to compute the eigenmodes. Numerical simulations show that our method is very practical and efficient for computing eigenmodes.

  11. Query and Update Efficient B+-Tree Based Indexing of Moving Objects

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Lin, Dan; Ooi, Beng Chin

    2004-01-01

    . This motivates the design of a solution that enables the B+-tree to manage moving objects. We represent moving-object locations as vectors that are timestamped based on their update time. By applying a novel linearization technique to these values, it is possible to index the resulting values using a single B...... are streamed to a database. Indexes for moving objects must support queries efficiently, but must also support frequent updates. Indexes based on minimum bounding regions (MBRs) such as the R-tree exhibit high concurrency overheads during node splitting, and each individual update is known to be quite costly......+-tree that partitions values according to their timestamp and otherwise preserves spatial proximity. We develop algorithms for range and k nearest neighbor queries, as well as continuous queries. The proposal can be grafted into existing database systems cost effectively. An extensive experimental study explores...

  12. FastBit: an efficient indexing technology for accelerating data-intensive science

    International Nuclear Information System (INIS)

    Wu Kesheng

    2005-01-01

    FastBit is a software tool for searching large read-only datasets. It organizes user data in a column-oriented structure which is efficient for on-line analytical processing (OLAP), and utilizes compressed bitmap indices to further speed up query processing. Analyses have proven the compressed bitmap index used in FastBit to be theoretically optimal for onedimensional queries. Compared with other optimal indexing methods, bitmap indices are superior because they can be efficiently combined to answer multi-dimensional queries whereas other optimal methods can not. In this paper, we first describe the searching capability of FastBit, then briefly highlight two applications that make extensive use of FastBit, namely Grid Collector and DEX

  13. FastBit: An Efficient Indexing Technology For AcceleratingData-Intensive Science

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kesheng

    2005-06-27

    FastBit is a software tool for searching large read-only data sets. It organizes user data in a column-oriented structure which is efficient for on-line analytical processing (OLAP), and utilizes compressed bitmap indices to further speed up query processing. Analyses have proven the compressed bitmap index used in FastBit to be theoretically optimal for one-dimensional queries. Compared with other optimal indexing methods, bitmap indices are superior because they can be efficiently combined to answer multi-dimensional queries whereas other optimal methods cannot. In this paper, we first describe the searching capability of FastBit, then briefly highlight two applications that make extensive use of FastBit, namely Grid Collector and DEX.

  14. FastBit: an efficient indexing technology for accelerating data-intensive science

    Science.gov (United States)

    Wu, Kesheng

    2005-01-01

    FastBit is a software tool for searching large read-only datasets. It organizes user data in a column-oriented structure which is efficient for on-line analytical processing (OLAP), and utilizes compressed bitmap indices to further speed up query processing. Analyses have proven the compressed bitmap index used in FastBit to be theoretically optimal for onedimensional queries. Compared with other optimal indexing methods, bitmap indices are superior because they can be efficiently combined to answer multi-dimensional queries whereas other optimal methods can not. In this paper, we first describe the searching capability of FastBit, then briefly highlight two applications that make extensive use of FastBit, namely Grid Collector and DEX.

  15. Gamma Radiation to Increase Efficiency of Bacillus thuringiensis Thai Strain for Insect Pets Control

    International Nuclear Information System (INIS)

    Chanpaisaeng, Jariya; Keawsompong, Suttipun; Piadang, Nattaya; Tephan, Prakai; Keawchingduang, Wannapa

    2006-09-01

    Bacillus thuringiensis (Bt) isolates JCPT16 and JCPT68 were gamma-irradiated at 2, 4, 6 and 8 kGy. The efficiency of these Bt isolates on S. litura control was also undertaken. It was found that the 4 kGy irradiated JCPT16 isolate had lowest LC 50 of 6.6x10 3 spore/ml while the non-irradiated JCPT 16 isolate had LC 50 of 6.2x10 3 spore/ml. Whereas the irradiated JCPT68 isolate at 8 kGy was noticed to have the lowest LC 50 of 2.7 x 10 3 spores/ml, the non-irradiated JCPT68 had LC 50 of 1.8x10 3 spores/ml. The efficiency test of B. thuringiensis isolate on S. exigua showed that the 2 kGy irradiated JCPT16 isolate had the lowest LC 50 of 2.52x10 4 spores/ml while the non-irradiated JCPT16 isolate had LC 50 of 6.04x10 3 spores/ml. The irradiated JCPT68 isolate at 4 kGy had the lowest LC 50 of 5.41x10 4 spores/ml, the non irradiated JCPT68 had LC 50 of 1.51x10 4 spores/ml. According to LC 50 values, there were no significant differences of efficiency on S. litura and S. exigua control among Bt isolates irradiated at various concentrations. The isolate JCPT16, JCPT35, JCPT50 and JCPT68 irradiated at dose of 10 kGy showed higher UV tolerance. After expose by UV ray, most of irradiated isolates still displayed high efficiency of controlling S. litura, S. exigua and Plutella xylostell.

  16. Development of source-less efficiency calibration procedure for CeBr3 based gamma spectrometry system

    International Nuclear Information System (INIS)

    Verma, Amit K.; Narayani, K.; Pant, Amar D.; Bhosale, Nitin; Anilkumar, S.; Palani Selvam, T.

    2018-01-01

    Scintillation spectrometers are widely used in detection and spectrometry of gamma photons. Sodium Iodide (NaI(Tl)) is the most commonly used scintillation detector for gamma ray spectrometry. However for portable application that require higher efficiency and better resolution Cerium Bromide (CeBr 3 ) crystals are more suitable than NaI(Tl) crystals. CeBr 3 detectors have high light output (∼ 68,000 photons/MeV), good proportionality, fast response and better energy resolution (<4% for 662 keV of 137 Cs), which makes it very promising detector for gamma ray spectrometry. In the present work, experimental and Monte Carlo based efficiencies for CeBr 3 detector for 137 Cs and 60 Co were evaluated

  17. Calculating concentration of inhaled radiolabeled particles from external gamma counting: External counting efficiency and attenuation coefficient of thorax

    International Nuclear Information System (INIS)

    Langenback, E.G.; Foster, W.M.; Bergofsky, E.H.

    1989-01-01

    We determined the overall external counting efficiency of radiolabeled particles deposited in the sheep lung. This efficiency permits the noninvasive calculation of the number of particles and microcuries from gamma-scintillation lung images of the live sheep. Additionally, we have calculated the attenuation of gamma radiation (120 keV) by the posterior chest wall and the gamma-scintillation camera collection efficiency of radiation emitted from the lung. Four methods were employed in our experiments: (1) by light microscopic counting of discrete carbonized polystyrene particles with a count median diameter (CMD) of 2.85 microns and tagged with cobalt-57, we delineated a linear relationship between the number of particles and the emitted counts per minute (cpm) detected by well scintillation counting; (2) from this conversion relationship we determined the number of particles inhaled and deposited in the lungs by scintillation counting fragments of dissected lung at autopsy; (3) we defined a linear association between the number of particles or microcuries contained in the lung and the emitted radiation as cpm detected by a gamma scintillation camera in the live sheep prior to autopsy; and (4) we compared the emitted radiation from the lungs of the live sheep to that of whole excised lungs in order to calculate the attenuation coefficient (ac) of the chest wall. The mean external counting efficiency was 4.00 X 10(4) particles/cpm (5.1 X 10(-3) microCi/cpm), the camera collection efficiency was 1 cpm/10(4) disintegrations per minute (dpm), and the ac had a mean of 0.178/cm. The external counting efficiency remained relatively constant over a range of particles and microcuries, permitting a more general use of this ratio to estimate number of particles or microcuries depositing after inhalation in a large mammalian lung if a similarly collimated gamma camera system is used

  18. Gamma Knife

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Gamma Knife Gamma Knife® is a radiation therapy that uses computerized ... If you're scheduled for radiation therapy using Gamma Knife®, a treatment team consisting of a radiation ...

  19. Energy efficiency index to artificially conditioned buildings; Indice de eficiencia energetica para edificios climatizados artificialmente

    Energy Technology Data Exchange (ETDEWEB)

    Jota, Patricia Romeiro da Silva; Santos, Carla da Silva; Costa, Kelly Luciene C. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEMIG/CEFET), Belo Horizonte, MG (Brazil). Centro de Pesquisa em Energia Inteligente

    2010-07-01

    Conditioning buildings has been growing in number and are responsible for a significant portion of the energy used worldwide. The building energy use can be measured by the index of energy performance and specific fuel consumption (EC). The specific consumption is an index where the energy is normalized by the factors that affect energy use in order to obtain an index to explain variations in consumption. In this paper, we present a methodology to obtain a specific consumption that takes into account one of the factors that most affect energy use in these buildings, that is, the external temperature. The study is based on analysis of consumption of air conditioning system according to temperature. Through this analysis we obtain a function to facilitate the standardization of energy use, depending on the temperature outside. This methodology was tested in previous work on real buildings without stratification of energy, and this work will be presented a case study of a building whose energy measurement is stratified. The proposed index is the ratio between the energy consumption of air conditioning system corrected by the temperature through the function K(T). It was possible to demonstrate the efficiency of the index to eliminate the effect of temperature and thus to evaluate the evolution of specific consumption over the months analyzed. (author)

  20. Assessing sample attenuation parameters for use in low-energy efficiency transfer in gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Bruggeman, M.; Verheyen, L.; Vidmar, T.; Liu, B.

    2016-01-01

    We present a numerical fitting method for transmission data that outputs an equivalent sample composition. This output is used as input to a generalised efficiency transfer model based on the EFFTRAN software integrated in a LIMS. The procedural concept allows choosing between efficiency transfer with a predefined sample composition or with an experimentally determined composition based on a transmission measurement. The method can be used for simultaneous quantification of low-energy gamma emitters like "2"1"0Pb, "2"4"1Am, "2"3"4Th in typical environmental samples. - Highlights: • New fitting method for experimentally determined attenuation coefficients. • Generalised efficiency transfer with EFFTRAN based on transmission measurements. • Method of generalized efficiency transfer integrated in LIMS. • Method applicable to gamma-ray spectrometry of environmental samples.

  1. Measurements of the light conversion efficiency of lithium borate for alpha particles relative to cobalt-60 gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, D.T.; Wall, B.F.; Fisher, E.S. (National Radiological Protection Board, Harwell (UK))

    1982-01-01

    The results are reported of measurements of the light conversion efficiencies of lithium borate TLD phosphor of British Nuclear Fuels Ltd. manufacture to 5.65 MeV and 2.4 MeV alpha particles relative to /sup 60/Co gamma radiation.

  2. Measurement and decomposition of energy efficiency of Northeast China-based on super efficiency DEA model and Malmquist index.

    Science.gov (United States)

    Ma, Xiaojun; Liu, Yan; Wei, Xiaoxue; Li, Yifan; Zheng, Mengchen; Li, Yudong; Cheng, Chaochao; Wu, Yumei; Liu, Zhaonan; Yu, Yuanbo

    2017-08-01

    Nowadays, environment problem has become the international hot issue. Experts and scholars pay more and more attention to the energy efficiency. Unlike most studies, which analyze the changes of TFEE in inter-provincial or regional cities, TFEE is calculated with the ratio of target energy value and actual energy input based on data in cities of prefecture levels, which would be more accurate. Many researches regard TFP as TFEE to do analysis from the provincial perspective. This paper is intended to calculate more reliably by super efficiency DEA, observe the changes of TFEE, and analyze its relation with TFP, and it proves that TFP is not equal to TFEE. Additionally, the internal influences of the TFEE are obtained via the Malmquist index decomposition. The external influences of the TFFE are analyzed afterward based on the Tobit models. Analysis results demonstrate that Heilongjiang has the highest TFEE followed by Jilin, and Liaoning has the lowest TFEE. Eventually, some policy suggestions are proposed for the influences of energy efficiency and study results.

  3. The no-arbitrage efficiency test of the OMX Index option market

    DEFF Research Database (Denmark)

    Hou, Ai Jun; Wiktorsson, Magnus; Zhao, RuiZhi

    2012-01-01

    In this paper, we test the market efficiency of the OMXS30 Index option market. The market efficiency definition is the absence of arbitrage oppor- tunity in the market. We first check the arbitrage opportunity by examining the boundary conditions and the Put-Call-Parity that must be satisfied...... in the market. Then a variance based efficiency test is performed by establish- ing a risk neutral portfolio and re-balance the initial portfolio in different trading strategies. In order to choose the most appropriate model for option price and hedging strategies, we calibrate several most applied models, i.......e. the BS, Merton, Heston, Bates model and Affine Jump Diffusion models. Our results indicate that the AJD model significantly outperforms other models in the option price forecast and the trading strategies. The bound- ary and the PCP test and the dynamic hedging strategy results evidence...

  4. A Moving-Object Index for Efficient Query Processing with PeerWise Location Privacy

    DEFF Research Database (Denmark)

    Lin, Dan; Jensen, Christian S.; Zhang, Rui

    2011-01-01

    attention has been paid to enabling so-called peer-wise privacy—the protection of a user’s location from unauthorized peer users. This paper identifies an important efficiency problem in existing peer-privacy approaches that simply apply a filtering step to identify users that are located in a query range......, but that do not want to disclose their location to the querying peer. To solve this problem, we propose a novel, privacy-policy enabled index called the PEB-tree that seamlessly integrates location proximity and policy compatibility. We propose efficient algorithms that use the PEB-tree for processing privacy......-aware range and kNN queries. Extensive experiments suggest that the PEB-tree enables efficient query processing....

  5. Efficiency limit of solar cells with index-near-zero photon management layers

    International Nuclear Information System (INIS)

    Kirk, A.P.

    2017-01-01

    As single-junction solar cells saturate in efficiency, the topic of photon management has generated interest in the long running quest to exceed the Shockley-Queisser efficiency limit. While a mirror applied to the backside of a solar cell has proven its benefit as a photon management layer in record setting devices that fall within the Shockley-Queisser limit, it has been proposed that a new type of photon management layer – a transparent index-near-zero (INZ) material – applied to the top surface of a solar cell will allow it to finally exceed the Shockley-Queisser limit. INZ layers – and their influence on solar cell current density, open circuit voltage, and power conversion efficiency – are analyzed. By considering the principle of detailed balance, Snell's law, and the role that entropy plays, it is shown that INZ layers do not allow a solar cell to exceed the Shockley-Queisser efficiency limit. At best, a solar cell with an INZ layer would have the same Shockley-Queisser limiting efficiency as a conventional solar cell tracked under a direct solar spectrum (direct beam radiation only), yet would suffer diminished efficiency under a global solar spectrum (direct beam plus diffuse light) due to the presence of an external critical acceptance angle.

  6. Efficiency limit of solar cells with index-near-zero photon management layers

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, A.P.

    2017-05-15

    As single-junction solar cells saturate in efficiency, the topic of photon management has generated interest in the long running quest to exceed the Shockley-Queisser efficiency limit. While a mirror applied to the backside of a solar cell has proven its benefit as a photon management layer in record setting devices that fall within the Shockley-Queisser limit, it has been proposed that a new type of photon management layer – a transparent index-near-zero (INZ) material – applied to the top surface of a solar cell will allow it to finally exceed the Shockley-Queisser limit. INZ layers – and their influence on solar cell current density, open circuit voltage, and power conversion efficiency – are analyzed. By considering the principle of detailed balance, Snell's law, and the role that entropy plays, it is shown that INZ layers do not allow a solar cell to exceed the Shockley-Queisser efficiency limit. At best, a solar cell with an INZ layer would have the same Shockley-Queisser limiting efficiency as a conventional solar cell tracked under a direct solar spectrum (direct beam radiation only), yet would suffer diminished efficiency under a global solar spectrum (direct beam plus diffuse light) due to the presence of an external critical acceptance angle.

  7. Efficiency limit of solar cells with index-near-zero photon management layers

    Science.gov (United States)

    Kirk, A. P.

    2017-05-01

    As single-junction solar cells saturate in efficiency, the topic of photon management has generated interest in the long running quest to exceed the Shockley-Queisser efficiency limit. While a mirror applied to the backside of a solar cell has proven its benefit as a photon management layer in record setting devices that fall within the Shockley-Queisser limit, it has been proposed that a new type of photon management layer - a transparent index-near-zero (INZ) material - applied to the top surface of a solar cell will allow it to finally exceed the Shockley-Queisser limit. INZ layers - and their influence on solar cell current density, open circuit voltage, and power conversion efficiency - are analyzed. By considering the principle of detailed balance, Snell's law, and the role that entropy plays, it is shown that INZ layers do not allow a solar cell to exceed the Shockley-Queisser efficiency limit. At best, a solar cell with an INZ layer would have the same Shockley-Queisser limiting efficiency as a conventional solar cell tracked under a direct solar spectrum (direct beam radiation only), yet would suffer diminished efficiency under a global solar spectrum (direct beam plus diffuse light) due to the presence of an external critical acceptance angle.

  8. a Novel Approach of Indexing and Retrieving Spatial Polygons for Efficient Spatial Region Queries

    Science.gov (United States)

    Zhao, J. H.; Wang, X. Z.; Wang, F. Y.; Shen, Z. H.; Zhou, Y. C.; Wang, Y. L.

    2017-10-01

    Spatial region queries are more and more widely used in web-based applications. Mechanisms to provide efficient query processing over geospatial data are essential. However, due to the massive geospatial data volume, heavy geometric computation, and high access concurrency, it is difficult to get response in real time. Spatial indexes are usually used in this situation. In this paper, based on k-d tree, we introduce a distributed KD-Tree (DKD-Tree) suitbable for polygon data, and a two-step query algorithm. The spatial index construction is recursive and iterative, and the query is an in memory process. Both the index and query methods can be processed in parallel, and are implemented based on HDFS, Spark and Redis. Experiments on a large volume of Remote Sensing images metadata have been carried out, and the advantages of our method are investigated by comparing with spatial region queries executed on PostgreSQL and PostGIS. Results show that our approach not only greatly improves the efficiency of spatial region query, but also has good scalability, Moreover, the two-step spatial range query algorithm can also save cluster resources to support a large number of concurrent queries. Therefore, this method is very useful when building large geographic information systems.

  9. A NOVEL APPROACH OF INDEXING AND RETRIEVING SPATIAL POLYGONS FOR EFFICIENT SPATIAL REGION QUERIES

    Directory of Open Access Journals (Sweden)

    J. H. Zhao

    2017-10-01

    Full Text Available Spatial region queries are more and more widely used in web-based applications. Mechanisms to provide efficient query processing over geospatial data are essential. However, due to the massive geospatial data volume, heavy geometric computation, and high access concurrency, it is difficult to get response in real time. Spatial indexes are usually used in this situation. In this paper, based on k-d tree, we introduce a distributed KD-Tree (DKD-Tree suitbable for polygon data, and a two-step query algorithm. The spatial index construction is recursive and iterative, and the query is an in memory process. Both the index and query methods can be processed in parallel, and are implemented based on HDFS, Spark and Redis. Experiments on a large volume of Remote Sensing images metadata have been carried out, and the advantages of our method are investigated by comparing with spatial region queries executed on PostgreSQL and PostGIS. Results show that our approach not only greatly improves the efficiency of spatial region query, but also has good scalability, Moreover, the two-step spatial range query algorithm can also save cluster resources to support a large number of concurrent queries. Therefore, this method is very useful when building large geographic information systems.

  10. Absolute 22Na radioactivity measurement by gamma efficiency variation of 4πβ-γ coincidence method

    International Nuclear Information System (INIS)

    Hino, Yoshio; Kawada, Yasusi.

    1994-01-01

    The absolute radioactivity of 22 Na was obtained by gamma efficiency variation of 4πβ-γ coincidence method. Some other previous techniques, such as sum peak gate method based on the positron emission rate, relative measurement with calibrated ionization chambers, and gamma spectrometry with a HPGe detector, were also tried to ensure the present result. The results of these methods were in reasonable agreement with the present absolute measurement. The assayed source solution of this experiment was transferred to NBS type ampoules, and sealed ampoules were sent to the SIR (International Reference System) in BIPM, Taiwan and Indonesia for the international comparison. (author)

  11. Exposition index calculation from different points in a gamma sterilization plant radiation room

    International Nuclear Information System (INIS)

    Carrasco, A.H.

    1983-01-01

    Radiation fields produced by a JS-6500 rectangular irradiator source were evaluated. Knowledge of the values of these fields is necessary in irradiation and health physics processes. Techniques for evaluating the dose rates from puntual, linear and plane sources were applied and computer programs for the three sources designed. Fricke, cupric-ferrous and red acrilic dosimetric systems were used, to verify the eight points located along the interior walls of the irradiation room, around the source with 936, 987 Ci of Co-60 (1st-March 1980). When considering the distance between the source and each point of interest the calculated exposition indexes obtained were practically the same for the three source types and were up to 35% greater than the experimental values; in contrast when absorption and buildup of the source were taken in to account, the experimental values were higher than the calculated ones by up to 16%, this in estimating the produced exposition index for a rectangular source at least there two parameters should be included. (author)

  12. Exploring energy efficiency in several European countries. An attribution analysis of the Divisia structural change index

    International Nuclear Information System (INIS)

    Fernández González, P.

    2015-01-01

    Highlights: • We present a new attribution analysis approach to study structural change index. • Based on LMDI method, we decompose changes in AEI in the EU in 1995–2010. • Mild AEI drop as a result of structural change, particularly in Eastern economies. • Transport, hotels and restaurants: positive contributors, specifically in Western EU. • Strategies should be focused on Industry: the most influential sector in reducing AEI. - Abstract: This paper aims at exploring the influence that the changes in sectoral composition in most EU economies have had on aggregate energy intensity. We rely on the so-called Logarithmic Mean Divisia Index (LMDI) method, implemented within a multiplicative energy intensity approach. Then, based on the Index Decomposition Analysis (IDA), we present, develop and apply a new methodology that enables the exploration of the contribution of each sector to the percent change in the structural factors index. Our findings show: (a) a greater importance of the intensity factor over the structural one, (b) a positive influence of structural change in some ex-communist countries, and (c) a strong, negative contribution of the industrial sector (including construction) to changes in aggregate energy intensity in most European economies, particularly in the Western ones. In short, adaptation to more efficient techniques, innovation, R and D, and substitution for higher quality energies, seem to be the action lines to follow, although in former communist countries these strategies should be accompanied by other policies aiming at accelerating the transition processes

  13. Gamma-glutamyltransferase, fatty liver index and hepatic insulin resistance are associated with incident hypertension in two longitudinal studies.

    Science.gov (United States)

    Bonnet, Fabrice; Gastaldelli, Amalia; Pihan-Le Bars, Florence; Natali, Andrea; Roussel, Ronan; Petrie, John; Tichet, Jean; Marre, Michel; Fromenty, Bernard; Balkau, Beverley

    2017-03-01

    We hypothesized that liver markers and the fatty liver index (FLI) are predictive of incident hypertension and that hepatic insulin resistance plays a role. The association between liver markers and incident hypertension was analysed in two longitudinal studies of normotensive individuals, 2565 from the 9-year data from an epidemiological study on the insulin resistance cohort and the 321 from the 3-year 'Relationship between Insulin Sensitivity and Cardiovascular disease' cohort who had a measure of endogenous glucose production. The FLI is calculated from BMI, waist circumference, triglycerides and gamma-glutamyltransferase (GGT) and the hepatic insulin resistance index from endogenous glucose production and fasting insulin. The incidence of hypertension increased across the quartiles groups of both baseline GGT and alanine aminotransferase. After adjustment for sex, age, waist circumference, fasting glucose, smoking and alcohol intake, only GGT was significantly related with incident hypertension [standardized odds ratio: 1.21; 95% confidence interval (1.10-1.34); P = 0.0001]. The change in GGT levels over the follow-up was also related with an increased risk of hypertension, independently of changes in body weight. FLI analysed as a continuous value, or FLI at least 60 at baseline were predictive of incident hypertension in the multivariable model. In the RISC cohort, the hepatic insulin resistance index was positively related with the risk of 3-year incident hypertension [standardized odds ratio: 1.54 (1.07-2.22); P = 0.02]. Baseline GGT and FLI, as well as an increase in GGT over time, were associated with the risk of incident hypertension. Enhanced hepatic insulin resistance predicted the onset of hypertension and may be a link between liver markers and hypertension.

  14. Gasdynamics of relativistically expanding gamma-ray burst sources - Kinematics, energetics, magnetic fields, and efficiency

    Science.gov (United States)

    Meszaros, P.; Laguna, P.; Rees, M. J.

    1993-01-01

    We calculate both analytically and numerically the evolution of highly relativistic fireballs through the stages of free expansion and coasting, and determine the dependence of the thermodynamic and radiation variables in the comoving and laboratory flames. The dynamics and the comoving geometry change at the (lab) expansion factors r/r(0) greater than eta and r/r(0) greater than eta-squared, respectively, where eta = E(0)/M(0)c-squared is the initial Lorentz factor. In the lab, the gas appears concentrated in a thin shell of width r(0) until r/r(0) of less than about eta-squared, and increases linearly after that. Magnetic fields may have been important in the original impulsive event. We discuss their effect on the fireball dynamics and also consider their effects on the radiation emitted when the fireball runs into an external medium and is decelerated. The inverse synchro-Compton mechanism can then yield high radiative efficiency in the reverse shock (and through turbulent instabilities and mixing also in the forward blast wave), producing a burst of nonthermal radiation mainly in the MeV to GeV range. The energy and duration depend on eta, the magnetic field strength, and the external density, and can match the range of properties observed in cosmic gamma-ray bursts.

  15. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    Science.gov (United States)

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Delta, theta, beta, and gamma brain oscillations index levels of auditory sentence processing.

    Science.gov (United States)

    Mai, Guangting; Minett, James W; Wang, William S-Y

    2016-06-01

    A growing number of studies indicate that multiple ranges of brain oscillations, especially the delta (δ, processing. It is not clear, however, how these oscillations relate to functional processing at different linguistic hierarchical levels. Using scalp electroencephalography (EEG), the current study tested the hypothesis that phonological and the higher-level linguistic (semantic/syntactic) organizations during auditory sentence processing are indexed by distinct EEG signatures derived from the δ, θ, β, and γ oscillations. We analyzed specific EEG signatures while subjects listened to Mandarin speech stimuli in three different conditions in order to dissociate phonological and semantic/syntactic processing: (1) sentences comprising valid disyllabic words assembled in a valid syntactic structure (real-word condition); (2) utterances with morphologically valid syllables, but not constituting valid disyllabic words (pseudo-word condition); and (3) backward versions of the real-word and pseudo-word conditions. We tested four signatures: band power, EEG-acoustic entrainment (EAE), cross-frequency coupling (CFC), and inter-electrode renormalized partial directed coherence (rPDC). The results show significant effects of band power and EAE of δ and θ oscillations for phonological, rather than semantic/syntactic processing, indicating the importance of tracking δ- and θ-rate phonetic patterns during phonological analysis. We also found significant β-related effects, suggesting tracking of EEG to the acoustic stimulus (high-β EAE), memory processing (θ-low-β CFC), and auditory-motor interactions (20-Hz rPDC) during phonological analysis. For semantic/syntactic processing, we obtained a significant effect of γ power, suggesting lexical memory retrieval or processing grammatical word categories. Based on these findings, we confirm that scalp EEG signatures relevant to δ, θ, β, and γ oscillations can index phonological and semantic/syntactic organizations

  17. Assessing Green Development Efficiency of Municipalities and Provinces in China Integrating Models of Super-Efficiency DEA and Malmquist Index

    Directory of Open Access Journals (Sweden)

    Qing Yang

    2015-04-01

    Full Text Available In order to realize economic and social green development, to pave a pathway towards China’s green regional development and develop effective scientific policy to assist in building green cities and countries, it is necessary to put forward a relatively accurate, scientific and concise green assessment method. The research uses the CCR (A. Charnes & W. W. Cooper & E. Rhodes Data Envelopment Analysis (DEA model to obtain the green development frontier surface based on 31 regions’ annual cross-section data from 2008–2012. Furthermore, in order to classify the regions whereby assessment values equal to 1 in the CCR model, we chose the Super-Efficiency DEA model for further sorting. Meanwhile, according to the five-year panel data, the green development efficiency changes of 31 regions can be manifested by the Malmquist index. Finally, the study assesses the reasons for regional differences; while analyzing and discussing the results may allude to a superior green development pathway for China.

  18. Research on energy efficiency design index for sea-going LNG carriers

    Science.gov (United States)

    Lin, Yan; Yu, Yanyun; Guan, Guan

    2014-12-01

    This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters—fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.

  19. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  20. Counting efficiency for radionuclides decaying by beta and gamma-ray emission; Calculo de la eficiencia de recuento de nucleidos que experimentan desintegracion beta y desexcitacion gamma simple

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A.; Garcia-Torano, E.

    1988-07-01

    In this paper, counting efficiency vs figure of merit for beta and gamma-ray emitters has been computed. It is assumed that the decay scheme has only a gamma level and the beta-ray emission may be coincident with the gamma-rays or the internal-conversion electrons. The radionuclides tabulated are: 20 {sub 0}, 20{sub p}, 28{sub A}l, 35{sub p}, 41{sub A}r, 42{sub K}, 47{sub S}e, 62{sub F}e, 66{sub C}u, 81{sub G}e, 86{sub B}b, 108{sub R}u, 112{sub p}d, 121{sub S}n(Ni), 122{sub I}n, 129{sub I}, 141{sub C}e 171{sub T}m, 194{sub O}s, 2O3{sub H}g, 205{sub H}g, 210{sub p}b, 225{sub R}a, 142{sub p}r, 151{sub S}m, 244{sub A}m(m). It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 10 cm''3. (Author) 8 refs.

  1. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  2. Indexed

    CERN Document Server

    Hagy, Jessica

    2008-01-01

    Jessica Hagy is a different kind of thinker. She has an astonishing talent for visualizing relationships, capturing in pictures what is difficult for most of us to express in words. At indexed.blogspot.com, she posts charts, graphs, and Venn diagrams drawn on index cards that reveal in a simple and intuitive way the large and small truths of modern life. Praised throughout the blogosphere as “brilliant,” “incredibly creative,” and “comic genius,” Jessica turns her incisive, deadpan sense of humor on everything from office politics to relationships to religion. With new material along with some of Jessica’s greatest hits, this utterly unique book will thrill readers who demand humor that makes them both laugh and think.

  3. Tensorial dynamic time warping with articulation index representation for efficient audio-template learning.

    Science.gov (United States)

    Le, Long N; Jones, Douglas L

    2018-03-01

    Audio classification techniques often depend on the availability of a large labeled training dataset for successful performance. However, in many application domains of audio classification (e.g., wildlife monitoring), obtaining labeled data is still a costly and laborious process. Motivated by this observation, a technique is proposed to efficiently learn a clean template from a few labeled, but likely corrupted (by noise and interferences), data samples. This learning can be done efficiently via tensorial dynamic time warping on the articulation index-based time-frequency representations of audio data. The learned template can then be used in audio classification following the standard template-based approach. Experimental results show that the proposed approach outperforms both (1) the recurrent neural network approach and (2) the state-of-the-art in the template-based approach on a wildlife detection application with few training samples.

  4. Stochastic modeling of soundtrack for efficient segmentation and indexing of video

    Science.gov (United States)

    Naphade, Milind R.; Huang, Thomas S.

    1999-12-01

    Tools for efficient and intelligent management of digital content are essential for digital video data management. An extremely challenging research area in this context is that of multimedia analysis and understanding. The capabilities of audio analysis in particular for video data management are yet to be fully exploited. We present a novel scheme for indexing and segmentation of video by analyzing the audio track. This analysis is then applied to the segmentation and indexing of movies. We build models for some interesting events in the motion picture soundtrack. The models built include music, human speech and silence. We propose the use of hidden Markov models to model the dynamics of the soundtrack and detect audio-events. Using these models we segment and index the soundtrack. A practical problem in motion picture soundtracks is that the audio in the track is of a composite nature. This corresponds to the mixing of sounds from different sources. Speech in foreground and music in background are common examples. The coexistence of multiple individual audio sources forces us to model such events explicitly. Experiments reveal that explicit modeling gives better result than modeling individual audio events separately.

  5. Efficiency of cement - based low - weight shielding materials for Cs-137 gamma rays

    International Nuclear Information System (INIS)

    Satty, H. E. M.

    2014-10-01

    Due to the development of nuclear technology and use of technologies in various field of industry, medicine and research against ionizing radiation is one of the most important topics in this field. The purpose of this work is to reduce the dose rate from radioactive sources. The exposure to gamma radiation is leading to several health effects as the result of absorption by the human body. The frequently used shielding material for gamma rays is lead. In spite of its effectiveness and high mass attenuation coefficient, lower weight gamma shielding materials are required. In this effectiveness of three materials: carbon and mixture (50% carbon + 50% cement) was studied and compared to that of lead. The results were obtained in terms of the variations of the transmitted intensity. This is done using a gamma spectroscopy system.(Author)

  6. Do Forwarders Improve Sustainability Efficiency? Evidence from a European DEA Malmquist Index Calculation

    Directory of Open Access Journals (Sweden)

    Matthias Klumpp

    2017-05-01

    Full Text Available Sustainability performance and efficiency is an important topic in transportation and for forwarders. This is shown, for example, by the fact that major logistics service providers LSP publish sustainability reports, often within the annual legal business report. However, in depth research is missing regarding the efficiency of forwarders regarding the established triple bottom line approach for sustainability, including economic, social, and ecology performance areas. This is especially true for a dynamic time-series perspective, as usually only static analyses for one point in time are presented (in most cases single business years. Therefore, the operations research technique of a data envelopment analysis (DEA Malmquist index calculation is used in order to provide a longitudinal calculation of efficiency, incorporating multiple objectives regarding the triple bottom line approach for European forwarders. Several indicators are tested, including total revenues and assets as input types, profit (EBIT and dividend volume (economic dimension, employment and gender equality in management (social, and carbon-equivalent emissions (environmental as output types.

  7. Multielement CdZnTe detectors for high-efficiency, ambient-temperature gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Moss, C.E.; Sweet, M.R.; Ianakiev, K.; Reedy, R.C.; Li, J.; Valentine, J.D.

    1998-01-01

    CdZnTe is an attractive alternative to scintillator-based technology for ambient-temperature, gamma-ray spectroscopy. Large, single-element devices up to 3500 mm 3 have been developed for gamma-ray spectroscopy and are now available commercially. Because CdZnTe is a wide band-gap semiconductor, it can operate over a wide range of ambient temperatures with minimal power consumption. Over this range, CdZnTe detectors routinely yield better overall performance for gamma-ray spectroscopy than scintillator detectors. Manufacturing issues and material electronic properties limit the maximum size of single-element CdZnTe detectors. The authors are investigating methods to combine CdZnTe detectors together to improve detection efficiency and overall performance of gamma-ray spectroscopy. The applications include the assay and identification of radioisotopes for nuclear material safeguards and nonproliferation (over the energy range 50 keV to 1 MeV), and the analysis of elemental composition for planetary science (over the energy range 1 MeV to 10 MeV). Design issues for the two energy ranges are summarized

  8. SPECULATIVE EFFICIENCY OF STOCK INDEX FUTURES MARKETS:AN ANALYSIS ON THE ASEAN MARKETS

    Directory of Open Access Journals (Sweden)

    Normas Awang

    2012-07-01

    Full Text Available The capital markets in emerging economies are undergoing rapid transformationdue to the advancement of technologicalinnovations and globalization of themarketplace. Thus, the risk managementmeasures are extremely importantthroughout the financial system. However,the scarcity of derivative instrumentssuch as futures and options in emergingmarkets, in addition to the failure togenerate liquidity, have made the emerging economies to be left behind in therecent development of the world capital markets. Whilethere are a great numberof earlier studies that analyse the efficiency of futures markets in differentcountries, there is a lack ofresearch that take intoaccount of the speculativeefficiency of futures markets which argues that futures prices are an unbiased forecast of the spot pricesas well as a crucial part offorecasting techniques. Thispaper aims to investigate the speculativeefficiency of stock index futures marketsin the ASEAN markets which comprises ofSingapore, Malaysia and Thailand byemploying an econometric time series dataanalysis ranging from January 2000 toDecember 2010.

  9. A study on the performance evaluation of small gamma camera collimators using detective quantun efficiency

    International Nuclear Information System (INIS)

    Jeon, Ho Sang

    2008-02-01

    The anger-type gamma camera and novel marker compound using Tc-99m were firstly introduced in 1963. The gamma camera systems have being improved and applied to various fields, for example, medical, industrial, and environmental fields. Gamma camera is mainly composed of collimator, detector, and signal processor. And the radiative source is namely the imaging object. The collimator is essential component of gamma camera system because the imaging performance of system is mainly dependent on the collimator. The performance evaluation of collimators can be done by using evaluating factors. In this study, the novel factors for gamma camera evaluation are suggested. The established evaluating factors by NEMA are FWHM, sensitivity, and uniformity. They have some limitations in spite of their usefulness. Firstly, performance evaluation by those factors give insensitive and indirect results only. Secondly, the evaluation of noise property is ambiguous. Thirdly, there is no synthetic evaluation of system performance. Simulation with Monte Carlo code and experiment with a small camera camera were simultaenuously performed to verify novel evaluating factors. For the evaluation of spatial resolution, MTF was applied instead of FWHM. The MTF values presents excellent linear relationship with FWHM values. The NNPS was applied instead of uniformity and sensitivity for the evaluation of noise fluctuation. The NNPS values also presents linear relationship with sensitivity and unifomity. Moreover, these novel factors give quantities as the function of spatial frequencies. Finally, the DQE values were given by calculations with MTF, NNPS, and input SNR. DQE effectively presents the synthetic evaluation of gamma camera performance. It is the conclusion that MTF, NNPS, and DQE can be novel evaluating factors for gamma camera systems and the new factor for synthetic evaluation is derived

  10. On the Efficient Market Hypothesis of Stock Market Indexes: The Role of Non-synchronous Trading and Portfolio Effects

    OpenAIRE

    Ortiz, Roberto; Contreras, Mauricio; Villena, Marcelo

    2015-01-01

    In this article, the long-term behavior of the stock market index of the New York Stock Exchange is studied, for the period 1950 to 2013. Specifically, the CRSP Value-Weighted and CRSP Equal-Weighted index are analyzed in terms of market efficiency, using the standard ratio variance test, considering over 1600 one week rolling windows. For the equally weighted index, the null hypothesis of random walk is rejected in the whole period, while for the weighted market value index, the null hypothe...

  11. Effect of water stress on total biomass, tuber yield, harvest index and water use efficiency in Jerusalem artichoke

    Science.gov (United States)

    The objectives of this study were to determine the effect of drought on tuber yield, total biomass, harvest index, water use efficiency of tuber yield (WUEt) and water use efficiency of biomass (WUEb), and to evaluate the differential responses of Jerusalem artichoke (JA) varieties under drought str...

  12. A new computationally-efficient computer program for simulating spectral gamma-ray logs

    International Nuclear Information System (INIS)

    Conaway, J.G.

    1995-01-01

    Several techniques to improve the accuracy of radionuclide concentration estimates as a function of depth from gamma-ray logs have appeared in the literature. Much of that work was driven by interest in uranium as an economic mineral. More recently, the problem of mapping and monitoring artificial gamma-emitting contaminants in the ground has rekindled interest in improving the accuracy of radioelement concentration estimates from gamma-ray logs. We are looking at new approaches to accomplishing such improvements. The first step in this effort has been to develop a new computational model of a spectral gamma-ray logging sonde in a borehole environment. The model supports attenuation in any combination of materials arranged in 2-D cylindrical geometry, including any combination of attenuating materials in the borehole, formation, and logging sonde. The model can also handle any distribution of sources in the formation. The model considers unscattered radiation only, as represented by the background-corrected area under a given spectral photopeak as a function of depth. Benchmark calculations using the standard Monte Carlo model MCNP show excellent agreement with total gamma flux estimates with a computation time of about 0.01% of the time required for the MCNP calculations. This model lacks the flexibility of MCNP, although for this application a great deal can be accomplished without that flexibility

  13. Efficiency calibration and measurement of self-absorption correction of environmental gamma spectroscopy of soils samples using Marinelli beaker

    International Nuclear Information System (INIS)

    Abdi, M. R.; Mostajaboddavati, M.; Hassanzadeh, S.; Faghihian, H.; Rezaee, Kh.; Kamali, M.

    2006-01-01

    A nonlinear function in combination with the method of mixing activity calibrated is applied for fitting the experimental peak efficiency of HPGe spectrometers in 59-2614 keV energy range. The preparation of Marinelli beaker standards of mixed gamma and RG-set at secular equilibrium with its daughter radionuclides was studied. Standards were prepared by mixing of known amounts of 13B a, 241 Am, 152 Eu, 207 Bi, 24 Na, Al 2 O 3 powder and soil. The validity of these standards was checked by comparison with certified standard reference material RG-set and IAEA-Soil-6 Self-absorption was measured for the activity calculation of the gamma-ray lines about series of 238 U daughter, 232 Th series, 137 Cs and 40 K in soil samples. Self-absorption in the sample will depend on a number of factor including sample composition, density, sample size and gamma-ray energy. Seven Marinelli beaker standards were prepared in different degrees of compaction with bulk density ( ρ) of 1.000 to 1.600 g cm -3 . The detection efficiency versus density was obtained and the equation of self-absorption correction factors calculated for soil samples

  14. Low energy spectral index and Ep evolution of quasi-thermal photosphere emission of gamma-ray bursts

    International Nuclear Information System (INIS)

    Deng, Wei; Zhang, Bing

    2014-01-01

    Recent observations by the Fermi satellite suggest that a photosphere emission component is contributing to the observed spectrum of many gamma-ray bursts (GRBs). One important question is whether the photosphere component can interpret the typical 'Band' function of GRBs with a typical low energy photon spectral index α ∼ –1. We perform a detailed study of the photosphere emission spectrum by progressively introducing several physical ingredients previously not fully incorporated, including the probability distribution of the location of a dynamically evolving photosphere, superposition of emission from an equal arrival time 'volume' in a continuous wind, the evolution of optical depth of a wind with finite but evolving outer boundary, as well as the effect of different top-hat wind luminosity (L w ) profiles. By assuming a comoving blackbody spectrum emerging from the photosphere, we find that for an outflow with a constant or increasing L w , the low-energy spectrum below the peak energy (E p ), can be modified to F ν ∼ ν 1.5 (α ∼ +0.5). A softer (–1 < α < +0.5) or flat (α = –1) spectrum can be obtained during the L w decreasing phase or high-latitude-emission-dominated phase. We also study the evolution of E p as a function of wind and photosphere luminosity in this photosphere model. An E p – L tracking pattern can be reproduced if a certain positive dependence between the dimensionless entropy η and L w is introduced. However, the hard-to-soft evolution pattern cannot be reproduced unless a contrived condition is invoked. In order to interpret the Band spectrum, a more complicated photosphere model or a different energy dissipation and radiation mechanism is needed.

  15. EFFECT OF GAMMA RADIATION OF MACRO MUTATIONS, EFFECTIVENESS AND EFFICIENCY UNDER M2 GENERATION IN PEA (Pisum sativum L.

    Directory of Open Access Journals (Sweden)

    Arvind KUMAR

    2016-06-01

    Full Text Available The present investigation was undertaken to study the spectrum of macro mutants, effectiveness and efficiency of different doses of gamma rays in pea variety (Arkel. The seeds were treated with gamma rays viz., 00kR (dry control, 05kR, 10kR, 15kR, 20kR, 25kR, 30kR, 35kR, 40kR (dry seeds and presoaked seeds of the same was exposed to 00kR (wet control, 05kR, 10kR, 15kR, 20kR (kilo Roentgen biological damage was calculated in M1 and M2 generation based on lethality (L and pollen sterility. The irradiated seeds were sown in the M1 field their respective controls and harvested in bulk to raise the M2 generation in Randomized Block Design (RBD with three replications. The spectrum of macro mutants i.e., plant stature (tall, dwarf, small dwarf, maturity (early, late, pod shape (bold, long, short, seed colour (brown, light white, light green and seed shape (small, bold, wrinkled were observed in M2 generation. The usefulness of any mutagen in plant breeding depends not only on its effectiveness but also upon if efficiency. Mutagenic effectiveness is a measure of the frequency of mutations induced by unit mutagen dose, whereas mutagenic efficiency is measure of proportion of mutations in relation of undesirable changes like lethality and sterility are used for gamma rays. A result of the indicated positive relationship in M2 generation with macro mutation, effectiveness and efficiency was found to be highest at lowest doses.

  16. Cytochrome C effect on gamma-ray efficiency on barley seeds at different metabolic states

    International Nuclear Information System (INIS)

    Yankulov, M.

    1981-01-01

    Radiobiological studies of the effect of gamma-rays on the barley seeds were performed. It was shown that the different metabolic states of the seeds do not modify the effect of the independent treatment with cytochrome C, while the action of the gamma-rays is markedly modified. With the increase in the preliminary seed soaking time in H 2 O, the total lethality in the case of irradiated treatments rises from 54.10% to 91.00% and that of sterility to 13.13 and 57.44% for 12 and 72 hrs, respectively. The preliminary and post-irradiation treatment of seeds with cytochrome C markedly reduces the effect of gamma-rays, calculated by the criteria of general lethality and sterility, the trend towards an increase in the sensitivity with the increase in the extention of the preliminary soaking time of seeds in water being preserved. Preliminary soaking in the seeds in water also modifies the mutagenic effect of gamma-rays to a considerable extent. (author)

  17. On the Efficient Simulation of the Distribution of the Sum of Gamma-Gamma Variates with Application to the Outage Probability Evaluation Over Fading Channels

    KAUST Repository

    Ben Issaid, Chaouki; Rached, Nadhir B.; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2017-01-01

    the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is related to the difficult question of analyzing the statistics of a sum of Gamma- Gamma random variables

  18. Validation by theoretical approach to the experimental estimation of efficiency for gamma spectrometry of gas in 100 ml standard flask

    International Nuclear Information System (INIS)

    Mohan, V.; Chudalayandi, K.; Sundaram, M.; Krishnamony, S.

    1996-01-01

    Estimation of gaseous activity forms an important component of air monitoring at Madras Atomic Power Station (MAPS). The gases of importance are argon 41 an air activation product and fission product noble gas xenon 133. For estimating the concentration, the experimental method is used in which a grab sample is collected in a 100 ml volumetric standard flask. The activity of gas is then computed by gamma spectrometry using a predetermined efficiency estimated experimentally. An attempt is made using theoretical approach to validate the experimental method of efficiency estimation. Two analytical models named relative flux model and absolute activity model were developed independently of each other. Attention is focussed on the efficiencies for 41 Ar and 133 Xe. Results show that the present method of sampling and analysis using 100 ml volumetric flask is adequate and acceptable. (author). 5 refs., 2 tabs

  19. Determination of Carbamate and Organophosphorus Pesticides in Vegetable Samples and the Efficiency of Gamma-Radiation in Their Removal

    Directory of Open Access Journals (Sweden)

    Muhammed Alamgir Zaman Chowdhury

    2014-01-01

    Full Text Available In the present study, the residual pesticide levels were determined in eggplants (Solanum melongena (n=16, purchased from four different markets in Dhaka, Bangladesh. The carbamate and organophosphorus pesticide residual levels were determined by high performance liquid chromatography (HPLC, and the efficiency of gamma radiation on pesticide removal in three different types of vegetables was also studied. Many (50% of the samples contained pesticides, and three samples had residual levels above the maximum residue levels determined by the World Health Organisation. Three carbamates (carbaryl, carbofuran, and pirimicarb and six organophosphates (phenthoate, diazinon, parathion, dimethoate, phosphamidon, and pirimiphos-methyl were detected in eggplant samples; the highest carbofuran level detected was 1.86 mg/kg, while phenthoate was detected at 0.311 mg/kg. Gamma radiation decreased pesticide levels proportionately with increasing radiation doses. Diazinon, chlorpyrifos, and phosphamidon were reduced by 40–48%, 35–43%, and 30–45%, respectively, when a radiation strength of 0.5 kGy was utilized. However, when the radiation dose was increased to 1.0 kGy, the levels of the pesticides were reduced to 85–90%, 80–91%, and 90–95%, respectively. In summary, our study revealed that pesticide residues are present at high amounts in vegetable samples and that gamma radiation at 1.0 kGy can remove 80–95% of some pesticides.

  20. Efficient Multilevel and Multi-index Sampling Methods in Stochastic Differential Equations

    KAUST Repository

    Haji-Ali, Abdul Lateef

    2016-05-22

    of this thesis is the novel Multi-index Monte Carlo (MIMC) method which is an extension of MLMC in high dimensional problems with significant computational savings. Under reasonable assumptions on the weak and variance convergence, which are related to the mixed regularity of the underlying problem and the discretization method, the order of the computational complexity of MIMC is, at worst up to a logarithmic factor, independent of the dimensionality of the underlying parametric equation. We also apply the same multi-index methodology to another sampling method, namely the Stochastic Collocation method. Hence, the novel Multi-index Stochastic Collocation method is proposed and is shown to be more efficient in problems with sufficient mixed regularity than our novel MIMC method and other standard methods. Finally, MIMC is applied to approximate quantities of interest of stochastic particle systems in the mean-field when the number of particles tends to infinity. To approximate these quantities of interest up to an error tolerance, TOL, MIMC has a computational complexity of O(TOL-2log(TOL)2). This complexity is achieved by building a hierarchy based on two discretization parameters: the number of time steps in an Milstein scheme and the number of particles in the particle system. Moreover, we use a partitioning estimator to increase the correlation between two stochastic particle systems with different sizes. In comparison, the optimal computational complexity of MLMC in this case is O(TOL-3) and the computational complexity of Monte Carlo is O(TOL-4).

  1. Theoretical determination of gamma spectrometry systems efficiency based on probability functions. Application to self-attenuation correction factors

    Energy Technology Data Exchange (ETDEWEB)

    Barrera, Manuel, E-mail: manuel.barrera@uca.es [Escuela Superior de Ingeniería, University of Cadiz, Avda, Universidad de Cadiz 10, 11519 Puerto Real, Cadiz (Spain); Suarez-Llorens, Alfonso [Facultad de Ciencias, University of Cadiz, Avda, Rep. Saharaui s/n, 11510 Puerto Real, Cadiz (Spain); Casas-Ruiz, Melquiades; Alonso, José J.; Vidal, Juan [CEIMAR, University of Cadiz, Avda, Rep. Saharaui s/n, 11510 Puerto Real, Cádiz (Spain)

    2017-05-11

    A generic theoretical methodology for the calculation of the efficiency of gamma spectrometry systems is introduced in this work. The procedure is valid for any type of source and detector and can be applied to determine the full energy peak and the total efficiency of any source-detector system. The methodology is based on the idea of underlying probability of detection, which describes the physical model for the detection of the gamma radiation at the particular studied situation. This probability depends explicitly on the direction of the gamma radiation, allowing the use of this dependence the development of more realistic and complex models than the traditional models based on the point source integration. The probability function that has to be employed in practice must reproduce the relevant characteristics of the detection process occurring at the particular studied situation. Once the probability is defined, the efficiency calculations can be performed in general by using numerical methods. Monte Carlo integration procedure is especially useful to perform the calculations when complex probability functions are used. The methodology can be used for the direct determination of the efficiency and also for the calculation of corrections that require this determination of the efficiency, as it is the case of coincidence summing, geometric or self-attenuation corrections. In particular, we have applied the procedure to obtain some of the classical self-attenuation correction factors usually employed to correct for the sample attenuation of cylindrical geometry sources. The methodology clarifies the theoretical basis and approximations associated to each factor, by making explicit the probability which is generally hidden and implicit to each model. It has been shown that most of these self-attenuation correction factors can be derived by using a common underlying probability, having this probability a growing level of complexity as it reproduces more precisely

  2. Power industry restructuring and eco-efficiency changes: A new slacks-based model in Malmquist–Luenberger Index measurement

    International Nuclear Information System (INIS)

    Arabi, Behrouz; Munisamy, Susila; Emrouznejad, Ali; Shadman, Foroogh

    2014-01-01

    Measuring variations in efficiency and its extension, eco-efficiency, during a restructuring period in different industries has always been a point of interest for regulators and policy makers. This paper assesses the impacts of restructuring of procurement in the Iranian power industry on the performance of power plants. We introduce a new slacks-based model for Malmquist–Luenberger (ML) Index measurement and apply it to the power plants to calculate the efficiency, eco-efficiency, and technological changes over the 8-year period (2003–2010) of restructuring in the power industry. The results reveal that although the restructuring had different effects on the individual power plants, the overall growth in the eco-efficiency of the sector was mainly due to advances in pure technology. We also assess the correlation between efficiency and eco-efficiency of the power plants, which indicates a close relationship between these two steps, thus lending support to the incorporation of environmental factors in efficiency analysis. - Highlights: • We introduce a new slack-based model incorporating bad outputs to measure eco-efficiency. • Eco-efficiency change of power plants is measured over a restructuring period. • A success to enhance the eco-efficiency is revealed. • A close relationship between efficiency and eco-efficiency is shown

  3. SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Y [East Carolina Univ, Greenville, NC (United States); Huang, Z [East Carolina University, Greenville, NC (United States); Lo, S [Case Western Reserve University, Cleveland, OH (United States); Mayr, N; Yuh, W [University of Washington, Seattle, WA (United States)

    2015-06-15

    Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling, automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain

  4. SU-E-T-213: Comparison of Treatment Efficiency of Gamma Knife SRS Plans for Brain Metastases with Different Planning Methods

    International Nuclear Information System (INIS)

    Feng, Y; Huang, Z; Lo, S; Mayr, N; Yuh, W

    2015-01-01

    Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling, automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain

  5. International comparison of interpolation procedures for the efficiency of germanium gamma-ray spectrometers (GAM83 exercise)

    International Nuclear Information System (INIS)

    Zijp, W.L.; Polle, A.N.; Nolthenius, H.J.

    1986-01-01

    Results are presented for the outcome of an international intercomparison of a particular gamma-ray spectrometric procedure. Laboratories were asked to determine full energy peak efficiencies and activities by means of their own procedures, starting from supplied peak-efficiency data. Four data sets for four different conditions of germanium detectors were distributed. The sets comprised: a high accuracy- (uncertainty > 1%) data set with a relatively large number of measured data (SET 1); a low accuracy- (uncertainty 3-5%) data set with a relatively small number of measured data (SET 2); a low energy-data set (SET 3); a high accuracy-data set with a relatively small number of measured data (SET 4). The intercomparison (coded GAM83) was organized and analyzed under auspices of the International Committee for Radionuclide Metrology (ICRM). The results comprise the analysis of the contributions of 41 participants

  6. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr_3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. - Highlights: • A small-sized UAV airborne sensor system was developed. • Three radioactive models were chosen to simulate the Fukushima accident. • Both the air and ground radiation were considered in the models. • The efficiency calculations and MDAC values were given. • The sensor system is able to monitor in serious nuclear accidents.

  7. Standardization of low energy beta and beta-gamma complex emitters by the tracer and the efficiency extrapolation methods

    International Nuclear Information System (INIS)

    Sahagia, M.

    1978-01-01

    The absolute standardization of radioactive solutions of low energy beta emitters and beta-gamma emitters with a high probability of disintegration to the ground state is described; the tracer and the efficiency extrapolation methods were used. Both types of radionuclides were mathematically and physically treated in an unified manner. The theoretical relations between different beta spectra were calculated according to Williams' model and experimentally verified for: 35 S + 60 Co, 35 S + 95 Nb, 147 Pm + 60 Co, 14 C + 95 Nb and two beta branches of 99 Mo. The optimum range of beta efficiency variation was indicated. The basic supposition that all beta efficieny tend to unity in the same time was experimentally verified, using two 192 Ir beta branches. Four computer programs, written in the FORTRAN IV language, were elaborated, for the adequate processing of the experimental data. Good precision coefficients according to international standards were obtained in the absolute standardization of 35 S, 147 Pm, 99 Mo solutions. (author)

  8. Photopeak efficiency response function of an underwater gamma-ray NaI(Tl) detector using MCNP-X

    International Nuclear Information System (INIS)

    Salgado, William L.; Silva, Ademir X.; Salgado, Cesar M.

    2015-01-01

    This work presents a study to calculate the response function of a 1.5″ x 1″ NaI(Tl) scintillation detector when it is used in the marine environment in the energy range from 20 keV to 662 keV. The method takes into account both the scattering of photons in the water and the detection mechanism of the detector. In addition, the calculation of the response function of the whole system is essential for suppressing the background of the measurement and for estimating the concentration of the involved radionuclides, especially given the greater probability of primary gamma photons undergoing multiple scattering events before they interact with the detector. The experimental photopeak efficiency measurements for point sources were compared with the simulated results under the same conditions of the experimental setup to validate the simulation of the detector. Monte Carlo simulations were performed using the MCNP-X code for the investigation of gamma-ray absorption in water in different brines. The energy resolution curve was used to improve the response of the mathematical simulation of the detector. The detector’s simulation was based on information obtained from the gammagraphy technique. Both dimensions and materials were used for the calculation with the MCNP-X code. The photopeak efficiency of a NaI(Tl) detector for different radionuclides in the aquatic environment with different salinities was calculated. (author)

  9. On calculation of detection efficiency of gamma spectrometers with germanium detection

    International Nuclear Information System (INIS)

    Sima, O.

    2001-01-01

    High resolution gamma spectrometer represents a powerful analysis technique of use in various fields from basic research to the study of environmental radioactivity, from medical investigations to geological surveys. Direct experimental calibration cannot cover the large range of measurement configurations of interest. Actually, it can be appropriately applied in an only limited number of cases, as for instance, in case of point-like sources or liquid phase volume sources. To assist the treatment of experimental calibration of germanium detectors, in the frame of Atomic and Nuclear Physics Chair of Department of Physics, a number of calculation methods were developed. These methods are generally based on Monte Carlo simulation but simplified and fast analytical methods were also worked out. Initially, these studies were dedicated to application in the field of environmental activity and radiation protection, but later on these were extended also to other fields as, for instance, the neutron activation or radionuclide metrology. First, the effects of matrices were calculated for the case of volume sources. Applying the matrix corrections allows obtaining the source calibration curves on the basis of experimental calibration data obtained with liquid sources, in the same geometry. An algorithm based on Monte Carlo calculation and using techniques of correlated selection was obtained. This algorithm can be implemented in the gamma analysis programs giving for the first time the possibility of correct evaluation of matrix effects even during the analysis of gamma spectra. We used a set of additive relations applicable in case of volume sources with negligible self-absorption and obtained a number of linear relations useful in calibrating the large volume sources in presence of self-absorption, based on small volume standard sources. Also, we proposed analytical relations useful in the case of measurements of large volume samples, in case of Marinelli geometry. To

  10. Mean of the typical decoding rates: a new translation efficiency index based on the analysis of ribosome profiling data.

    Science.gov (United States)

    Dana, Alexandra; Tuller, Tamir

    2014-12-01

    Gene translation modeling and prediction is a fundamental problem that has numerous biomedical implementations. In this work we present a novel, user-friendly tool/index for calculating the mean of the typical decoding rates that enables predicting translation elongation efficiency of protein coding genes for different tissue types, developmental stages, and experimental conditions. The suggested translation efficiency index is based on the analysis of the organism's ribosome profiling data. This index could be used for example to predict changes in translation elongation efficiency of lowly expressed genes that usually have relatively low and/or biased ribosomal densities and protein levels measurements, or can be used for example for predicting translation efficiency of new genetically engineered genes. We demonstrate the usability of this index via the analysis of six organisms in different tissues and developmental stages. Distributable cross platform application and guideline are available for download at: http://www.cs.tau.ac.il/~tamirtul/MTDR/MTDR_Install.html. Copyright © 2015 Dana and Tuller.

  11. Can a canopy temperature-based stress index enhance water use efficiency in irrigated wine grape under arid conditions?

    Science.gov (United States)

    Enhancement of irrigation water use efficiency and water productivity in arid wine grape production regions is hindered by a lack of automated, real-time methods for monitoring and interpreting vine water status. A normalized, water stress index calculated from real-time vine canopy temperature meas...

  12. TH-CD-207A-10: Using the Gamma Index to Flag Changes in Anatomy During Radiation Therapy of Head and Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schaly, B; Battista, J [London Regional Cancer Program, London, Ontario (Canada); Department of Medical Biophysics, Western University, London, Ontario Canada (Canada); Kempe, J; Mitchell, S [London Regional Cancer Program, London, Ontario (Canada); Venkatesan, V [London Regional Cancer Program, London, Ontario (Canada); Schulich School of Medicine and Dentistry, Western University, London, Ontario (Canada)

    2016-06-15

    Purpose: This article presents a fast algorithm for comparing 3-D anatomy from Cone-Beam CT (CBCT) imaging using the gamma comparison index and to demonstrate how this can be used to flag patients for possible re-planning of treatment. Methods: CBCT scans acquired on a Varian linear accelerator during treatment were used as input to the gamma comparator using thresholds of 5 mm distance to agreement and 30 Hounsfield Unit CT number difference. The fraction 1 CBCT study was initially used as the reference. Should there be a re-plan during treatment, the reference resets to the CBCT study acquired on the day 1 of the re-plan. Histograms of failing pixels (γ > 1) were generated from each 3-D gamma map. An indicator of anatomy congruence, the match quality parameter (MQP), was derived from failed pixel histograms using the 90th percentile gamma value. The MQP was plotted versus fraction number and related to actual repeat computed tomography (re-CT) order dates as decided by a radiation oncologist. From this, decision criteria were derived for the algorithm to “trigger” re-CT consideration and predictive power was scored using receiver-operator characteristic (ROC) analysis. Results: The MQP plot generally showed that the on-line match from CBCT image guidance deteriorated as the treatment progressed due to weight loss and tumor regression. The optimized MQP criteria for triggering re-CT consideration demonstrated high sensitivity and specificity, consistent with actual re-CT order dates within ± 3 fractions. Out of 20 patients that were actually re-planned, the algorithm failed to trigger a re-CT recommendation only twice and this was caused by CBCT ring artifacts. Conclusion: We have demonstrated that gamma comparisons can be used to evaluate CBCT-acquired anatomy pairs and, from this, an algorithm can be “trained” to flag patients for possible re-planning in a manner consistent with local radiation oncology practice.

  13. A Spatiotemporal Indexing Approach for Efficient Processing of Big Array-Based Climate Data with MapReduce

    Science.gov (United States)

    Li, Zhenlong; Hu, Fei; Schnase, John L.; Duffy, Daniel Q.; Lee, Tsengdar; Bowen, Michael K.; Yang, Chaowei

    2016-01-01

    Climate observations and model simulations are producing vast amounts of array-based spatiotemporal data. Efficient processing of these data is essential for assessing global challenges such as climate change, natural disasters, and diseases. This is challenging not only because of the large data volume, but also because of the intrinsic high-dimensional nature of geoscience data. To tackle this challenge, we propose a spatiotemporal indexing approach to efficiently manage and process big climate data with MapReduce in a highly scalable environment. Using this approach, big climate data are directly stored in a Hadoop Distributed File System in its original, native file format. A spatiotemporal index is built to bridge the logical array-based data model and the physical data layout, which enables fast data retrieval when performing spatiotemporal queries. Based on the index, a data-partitioning algorithm is applied to enable MapReduce to achieve high data locality, as well as balancing the workload. The proposed indexing approach is evaluated using the National Aeronautics and Space Administration (NASA) Modern-Era Retrospective Analysis for Research and Applications (MERRA) climate reanalysis dataset. The experimental results show that the index can significantly accelerate querying and processing (10 speedup compared to the baseline test using the same computing cluster), while keeping the index-to-data ratio small (0.0328). The applicability of the indexing approach is demonstrated by a climate anomaly detection deployed on a NASA Hadoop cluster. This approach is also able to support efficient processing of general array-based spatiotemporal data in various geoscience domains without special configuration on a Hadoop cluster.

  14. Index Compression and Efficient Query Processing in Large Web Search Engines

    Science.gov (United States)

    Ding, Shuai

    2013-01-01

    The inverted index is the main data structure used by all the major search engines. Search engines build an inverted index on their collection to speed up query processing. As the size of the web grows, the length of the inverted list structures, which can easily grow to hundreds of MBs or even GBs for common terms (roughly linear in the size of…

  15. MEASURES OF EFFICIENCY AND INVESTMENTS RETURN: AN STUDY OF BRAZILIAN ELECTRICITY DISTRIBUTORS WITH DATA ENVELOPMENT ANALYSIS, MALMQUIST INDEX AND ROI

    Directory of Open Access Journals (Sweden)

    Valter Saurin

    2013-03-01

    Full Text Available This paper aims to determine, in a group of companies from the Brazilian electric sector, if there is a relationship between the return on investment (ROI and the concept of efficiency estimated by the method Data Envelopment Analysis (DEA, as well as evaluating the growth of productivity based on Malmquist Index (Fare et al, 1996. The hypothesis is that firms that had return on investment higher during certain period of time are those employed their resources efficiently in getting their outputs (DEA efficient. The input (1 Products (5 DEA model correspond to the operating cost (I, the network length (km, the number of consumers and the market billed high, medium and low voltage, respectively. The sample consisted of 31 companies of Brazilian electricity distribution and timing of the study was from 2007 to 2009. We calculated the Malmquist index (M0, represented by the change in total factor productivity (TFPC, which is composed by the evolution of technical efficiency (EC and the change in the technological frontier (TC of the companies were also determined ROI for each period. We calculated the correlation between the TFPC, TC, EC, score the DEA and the ROI for the period 2007 to 2009. The results showed a positive correlation, although weak, between efficiency change and the indexes mentioned above, rejecting the initial hypothesis

  16. A Study of the Efficiency of Spatial Indexing Methods Applied to Large Astronomical Databases

    Science.gov (United States)

    Donaldson, Tom; Berriman, G. Bruce; Good, John; Shiao, Bernie

    2018-01-01

    Spatial indexing of astronomical databases generally uses quadrature methods, which partition the sky into cells used to create an index (usually a B-tree) written as database column. We report the results of a study to compare the performance of two common indexing methods, HTM and HEALPix, on Solaris and Windows database servers installed with a PostgreSQL database, and a Windows Server installed with MS SQL Server. The indexing was applied to the 2MASS All-Sky Catalog and to the Hubble Source catalog. On each server, the study compared indexing performance by submitting 1 million queries at each index level with random sky positions and random cone search radius, which was computed on a logarithmic scale between 1 arcsec and 1 degree, and measuring the time to complete the query and write the output. These simulated queries, intended to model realistic use patterns, were run in a uniform way on many combinations of indexing method and indexing level. The query times in all simulations are strongly I/O-bound and are linear with number of records returned for large numbers of sources. There are, however, considerable differences between simulations, which reveal that hardware I/O throughput is a more important factor in managing the performance of a DBMS than the choice of indexing scheme. The choice of index itself is relatively unimportant: for comparable index levels, the performance is consistent within the scatter of the timings. At small index levels (large cells; e.g. level 4; cell size 3.7 deg), there is large scatter in the timings because of wide variations in the number of sources found in the cells. At larger index levels, performance improves and scatter decreases, but the improvement at level 8 (14 min) and higher is masked to some extent in the timing scatter caused by the range of query sizes. At very high levels (20; 0.0004 arsec), the granularity of the cells becomes so high that a large number of extraneous empty cells begin to degrade

  17. A study on operation efficiency evaluation based on firm's financial index and benchmark selection: take China Unicom as an example

    Science.gov (United States)

    Wu, Zu-guang; Tian, Zhan-jun; Liu, Hui; Huang, Rui; Zhu, Guo-hua

    2009-07-01

    Being the only listed telecom operators of A share market, China Unicom has always been attracted many institutional investors under the concept of 3G recent years,which itself is a great technical progress expectation.Do the institutional investors or the concept of technical progress have signficant effect on the improving of firm's operating efficiency?Though reviewing the documentary about operating efficiency we find that schoolars study this problem useing the regress analyzing based on traditional production function and data envelopment analysis(DEA) and financial index anayzing and marginal function and capital labor ratio coefficient etc. All the methods mainly based on macrodata. This paper we use the micro-data of company to evaluate the operating efficiency.Using factor analyzing based on financial index and comparing the factor score of three years from 2005 to 2007, we find that China Unicom's operating efficiency is under the averge level of benchmark corporates and has't improved under the concept of 3G from 2005 to 2007.In other words,institutional investor or the conception of technical progress expectation have faint effect on the changes of China Unicom's operating efficiency. Selecting benchmark corporates as post to evaluate the operating efficiency is a characteristic of this method ,which is basicallly sipmly and direct.This method is suit for the operation efficiency evaluation of agriculture listed companies because agriculture listed also face technical progress and marketing concept such as tax-free etc.

  18. LYCOPENE EFFICIENCY IN THE MODULATION OF OXIDATIVE DAMAGE IN DIFFERENT TISSUES OF GAMMA IRRADIATED RATS

    International Nuclear Information System (INIS)

    EL-TAHAWY, N.A.; NADA, A.S.; REZK, R.G.

    2008-01-01

    Exposure to ionizing radiation induces oxidative stress that has been recognized as an important etiological factor in the causation of several chronic diseases. Lycopene, a carotenoid almost exclusively present in tomatoes and tomatoes products, is a lipid soluble antioxidant claimed to possess cardio protective and anticancer properties. The present study was designed to determine the possible modulator effects of lycopene on radiation-induced oxidative damage to liver, spleen and lung tissues. Animals were supplemented with lycopene (5 mg/kg body weight/ day) by gavages for two weeks before whole body exposure to gamma rays and within the period of irradiation (3 successive doses, each of 3 Gy at 72 hours intervals). Animals were sacrificed on the 3 r d day post the last irradiation session.The results obtained in the present study showed that whole body gamma irradiation produced oxidative stress manifested by significant elevation in lipid peroxides levels measured as thiobarbituric acid reactive substances (TBARS) associated with significant decrease of nitric oxide (NO) content. Non-significant change in total cupper (Cu) in the three tissues was recorded while significant increase of total iron (Fe) was observed in liver and spleen tissues only. Liver tissue of irradiated rats showed significant decrease in the activities of the antioxidant enzymes as superoxide dismutase (SOD) and catalase (CAT). In spleen tissues, there was a significant increase of SOD and significant decrease of CAT activities while in lung tissues, both SOD and CAT activities showed significant increase.Histological observations of photomicrograph of liver sections showed that radiation-induced sever damage obvious by dilated portal vein, ruptured hepatocytes, necrotic, pyknotic, karyolitic nuclei and vacuolated cytoplasm. In spleen tissue, radiation was induced degeneration of lymphatic nodules, dilation follicular artery and marked hemorrhage. In lung tissue, radiation- induces ill

  19. Photosynthetic Efficiency of Northern Forest Ecosystems Using a MODIS-Derived Photochemical Reflectance Index (PRI)

    Science.gov (United States)

    Middleton, E. M.; Huemmrich, K. F.; Landis, D. R.; Black, T. A.; Barr, A. G.; McCaughey, J. H.

    2016-01-01

    This study evaluates a direct remote sensing approach from space for the determination of ecosystem photosynthetic light use efficiency (LUE), through measurement of vegetation reflectance changes expressed with the Photochemical Reflectance Index (PRI). The PRI is a normalized difference index based on spectral changes at a physiologically active wavelength (approximately 531 nanometers) as compared to a reference waveband, and is only available from a very few satellites. These include the two Moderate-Resolution Imaging Spectroradiometers (MODIS) on the Aqua and Terra satellites each of which have a narrow (10-nanometer) ocean band centered at 531 nanometers. We examined several PRI variations computed with candidate reference bands, since MODIS lacks the traditional 570-nanometer reference band. The PRI computed using MODIS land band 1 (620-670 nanometers) gave the best performance for daily LUE estimation. Through rigorous statistical analyses over a large image collection (n equals 420), the success of relating in situ daily tower-derived LUE to MODIS observations for northern forests was strongly influenced by satellite viewing geometry. LUE was calculated from CO2 fluxes (moles per moles of carbon absorbed quanta) measured at instrumented Canadian Carbon Program flux towers in four Canadian forests: a mature fir site in British Columbia, mature aspen and black spruce sites in Saskatchewan, and a mixed deciduous/coniferous forest site in Ontario. All aspects of the viewing geometry had significant effects on the MODIS-PRI, including the view zenith angle (VZA), the view azimuth angle, and the displacement of the view azimuth relative to the solar principal plane, in addition to illumination related variables.Nevertheless, we show that forward scatter sector views (VZA, 16 degrees-45 degrees) provided the strongest relationships to daily LUE, especially those collected in the early afternoon by Aqua (r squared = 0.83, RMSE (root mean square error) equals 0

  20. Improving the efficiency of CDTN's Gamma Irradiation Laboratory with additional designed turntables

    International Nuclear Information System (INIS)

    Silva, Luiz Leite da; Albino, Sergio Celeghini; Candido, Marcos Antonio; Grossi, Pablo Andrade; Correa, Ricardo Ferracini; Pinto, Fausto Carvalho

    2007-01-01

    The Gamma Irradiation Laboratory (LIG) of CDTN was originally supplied with four turntables. Operating with this configuration was a loss of time and irradiation volume, what induced the Irradiator's staff creating an optimisation production program. Firstly, the staff requests the Gamma Irradiator Manufacturer a quotation for new turntables, but the price was very high. Secondly, the CDTN Design Group was invited to develop new LIG turntables. The groups worked together and found a very good solution. The new turntables are much cheaper and their rotating plate diameters are increased in 5 cm and four of them were made to attend the LIG demand. They have been in operation without significant problems for 1.5 years and absorbed an estimated dose of 7 MGy. This fact confirms the design and materials good quality. Operating with the eight turntables was possible to improve the LIG irradiation capacity in six times in weigh and in volume. Irradiation time is reduced; nowadays doses up to 5 KGy can be done in the same day. For irradiation doses greater than 5 KGy, the process was speeded up by positioning the new turntables in the spaces between the original ones. With this operational configuration the samples receive the dose escaped in those spaces. Calculation of the new dose necessary for the sample is done and it is repositioned in the internals turntables to finish the irradiation process. With this technique the samples do not need to wait so much on the line. The scope of the research program includes day and night operation. Continuously operating in association with the four new turntables enhanced the original operational capacity of the LIG fifteen times. The objectives of this work are to present the developed turntables characteristics and the results acquired. (author)

  1. GEOINFORMATION ANALYSIS OF THE INDEX OF BIOLOGICAL EFFICIENCY OF CLIMATE AS CRITERION FOR EVALUATION OF POTENTIAL STABILITY OF THE LANDSCAPE

    Directory of Open Access Journals (Sweden)

    A. N. Ogurtsov

    2017-01-01

    Full Text Available The article considers indicator approach to assessment of potential stability of landscapes. As an example of integrated criterion the index of climate biological efficiency (TK has been used. Calculations of TK index for assessment of stability of landscapes have been executed for the territory of Tver Region. Cartograms of TK index and its components have been made. Geospatial analysis has been carried out and estimates of potential stability of landscapes are given. The example of mapping and calculation of the TK index serves as a starting point for using it in multi-criteria assessment of the state and emergent properties of geosystems built on the principles of ASPID-methodology. This example reflects the possibility of using the indicator approach in the first stage of the study of resistance to changes in the parameters of natural regime for the subsequent multicriteria and integral assessment of resistance to changes in the parameters of natural and anthropogenic regimes of geosystems functioning. The use of the index of climate biological efficiency as an indicator of sustainability will make it possible to actively use it in future in geoecological research.

  2. The influence of the types of marine fuel over the Energy Efficiency Operational Index

    Science.gov (United States)

    Acomi, Nicoleta; Acomi, Ovidiu

    2014-05-01

    One of the main concerns of our society is certainly the environment protection. The international efforts for maintaining the environment clean are various and this paper refers to the efforts in the maritime transport field. Marine pollution consists of the water pollution and also the air pollution. Regardless of the delay in recognizing the later type of pollution, it rapidly gains many organizations to argue on it. The first step was including a dedicated annex (Annex VI) in the International Convention for the Prevention of Pollution from Ships, in 1997, which seeks to minimize the airborne emissions from ships. In order to control and minimize the air pollution, the International Maritime Organization has also developed a series of measures for monitoring the emissions. These measures are grouped in three main directions: technical, operational and management related. The subject of our study is the concept of Energy Efficiency Operational Index (EEOI), developed to provide ship-owners with assistance in the process of establishing the emissions from ships in operation, and to suggest the methods for achieving their reduction. As a monitoring tool, EEOI represents the mass of CO2 emitted per unit of transport work. The actual CO2 emission from combustion of fuel on board a ship during each voyage is calculated by multiplying total fuel consumption for each type of fuel (e.g. diesel oil, gas oil, light fuel oil, heavy fuel oil, liquefied petroleum gas, liquefied natural gas) with the carbon to CO2 conversion factor for the fuel in question. The performed transport work is calculated by multiplying mass of cargo (tonnes, number of TEU/cars, or number of passengers) with the distance in nautical miles corresponding to the transport work done. Using the software developed by the author it will be emphasized the variation of the EEOI value for one vessel using different types of fuel for the voyage's legs (distance to discharge port, distance to loading port, the

  3. DETEF a Monte Carlo system for the calculation of gamma spectrometers efficiency

    International Nuclear Information System (INIS)

    Cornejo, N.; Mann, G.

    1996-01-01

    The Monte Carlo method program DETEF calculates the efficiency of cylindrical NaI, Csi, Ge or Si, detectors for photons energy until 2 MeV and several sample geometric. These sources could be punctual, plane cylindrical or rectangular. The energy spectrum appears on the screen simultaneously with the statistical simulation. The calculated and experimental estimated efficiencies coincidence well in the standards deviations intervals

  4. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT

    International Nuclear Information System (INIS)

    Kim, Jung-in; Park, So-Yeon; Kim, Hak Jae; Kim, Jin Ho; Ye, Sung-Joon; Park, Jong Min

    2014-01-01

    To investigate the sensitivity of various gamma criteria used in the gamma-index method for patient-specific volumetric modulated arc therapy (VMAT) quality assurance (QA) for stereotactic body radiation therapy (SBRT) using a flattening filter free (FFF) photon beam. Three types of intentional misalignments were introduced to original high-definition multi-leaf collimator (HD-MLC) plans. The first type, referred to Class Out, involved the opening of each bank of leaves. The second type, Class In, involved the closing of each bank of leaves. The third type, Class Shift, involved the shifting of each bank of leaves towards the ground. Patient-specific QAs for the original and the modified plans were performed with MapCHECK2 and EBT2 films. The sensitivity of the gamma-index method using criteria of 1%/1 mm, 1.5%/1.5 mm, 1%/2 mm, 2%/1 mm and 2%/2 mm was investigated with absolute passing rates according to the magnitudes of MLCs misalignments. In addition, the changes in dose-volumetric indicators due to the magnitudes of MLC misalignments were investigated. The correlations between passing rates and the changes in dose-volumetric indicators were also investigated using Spearman’s rank correlation coefficient (γ). The criterion of 2%/1 mm was able to detect Class Out and Class In MLC misalignments of 0.5 mm and Class Shift misalignments of 1 mm. The widely adopted clinical criterion of 2%/2 mm was not able to detect 0.5 mm MLC errors of the Class Out or Class In types, and also unable to detect 3 mm Class Shift errors. No correlations were observed between dose-volumetric changes and gamma passing rates (γ < 0.8). Gamma criterion of 2%/1 mm was found to be suitable as a tolerance level with passing rates of 90% and 80% for patient-specific VMAT QA for SBRT when using MapCHECK2 and EBT2 film, respectively

  5. Full energy peak efficiency of NaI(Tl) gamma detectors and its analytical and semi-empirical representations

    International Nuclear Information System (INIS)

    Sudarshan, M.; Joseph, J.; Singh, R.

    1992-01-01

    The validity of various analytical functions and semi-empirical formulae proposed for representing the full energy peak efficiency (FEPE) curves of Ge(Li) and HPGe detectors has been tested for the FEPE of 7.6 cm x 7.6 cm and 5 cm x 5 cm Nal(Tl) detectors in the gamma energy range from 59.5 to 1408.03 keV. The functions proposed by East, and McNelles and Campbell provide by far the best representations of the present data. The semi-empirical formula of Mowatt describes the present data very well. The present investigation shows that some of the analytical functions and semi-empirical formulae, which represent the FEPE of the Ge(Li) and HPGe detectors very well, can be quite fruitfully used for Nal(Tl) detectors. (Author)

  6. An analytical calculation of the peak efficiency for cylindrical sources perpendicular to the detector axis in gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Julio C. [Autoridad Regulatoria Nuclear, Laboratorio de Espectrometria Gamma-CTBTO, Av. Del Libertador 8250, C1429BNP Buenos Aires (Argentina)], E-mail: jaguiar@sede.arn.gov.ar

    2008-08-15

    An analytical expression for the so-called full-energy peak efficiency {epsilon}(E) for cylindrical source with perpendicular axis to an HPGe detector is derived, using point-source measurements. The formula covers different measuring distances, matrix compositions, densities and gamma-ray energies; the only assumption is that the radioactivity is homogeneously distributed within the source. The term for the photon self-attenuation is included in the calculation. Measurements were made using three different sized cylindrical sources of {sup 241}Am, {sup 57}Co, {sup 137}Cs, {sup 54}Mn, and {sup 60}Co with corresponding peaks of 59.5, 122, 662, 835, 1173, and 1332 keV, respectively, and one measurement of radioactive waste drum for 662, 1173, and 1332 keV.

  7. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    Science.gov (United States)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Synthesis of Pt-Ru PSB-Py catalysis by {gamma}-irradiation and their electrocatalytic efficiency for methanol oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Ah; Sim, Kwang Sik; Choi, Seong Ho [Hannam University, Daejeon (Korea, Republic of); Jung, Sung Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-09-15

    We report here that deposition of Pt-Ru catalysis on the surface of core-shell conductive balls by radiation-chemical reduction of Pt and Ru ions, in order to use as catalysis in a fuel cell. The poly(styrene-co-4-vinylphenylboronic acid)-pyrrole (PSB-Py) with core-shell structure was obtained by in situ polymerization of pyrrole in the presence of the poly(styrene-co-4-vinylphenylboronic acid) (PSB). Subsequently, Pt-Ru catalysis were deposited onto PSB-Py ball by {gamma}-irradiation, in the presence/absence of poly(vinypyrolidone) (PVP) to prepare electrocatalysis for a fuel cell. The catalytic efficiency of Pt-Ru PSB-Py catalyst was examined for carbon monoxide (CO) stripping and methanol oxidation.

  9. The effect of gamma irradiation on the degree of ripening of mango by comparing the parameter of colour index, texture firmness and pH value

    International Nuclear Information System (INIS)

    Muhammad Hafiz Hanafi

    2012-01-01

    This study was carried out to determine the effect of low dose gamma irradiation on the ripening degree of cv Chokanan mangoes through the comparison of colour index changes, texture firmness and pH value. Harvested mature mango was studied through the storage period for 14 days. Dose level used were 0.00 kGy (control), 0.25 kGy, 0.50 kGy, 0.75 kGy and 1.00 kGy of gamma cell 220. All fruits were wrapped using plastic after irradiated. There was no change in 0 day. However, there are changes in colour index, firmness and pH value of fruits in after 3 days. Dose of 0.75 kGy and 1.00 kGy gave positive effect to storage extension period and rate deceleration compared to 0.00 kGy (control), 0.25 kGy and 0.50 kGy. After 10 days storage, 0.00, 0.25 and 0.50 kGy of fruits became rot which affects quality of organoleptic. Whereas 0.75 and 1.00 kGy still retained organoleptic quality . When the ripening rate of fruit was fast, this would lead to faster of the colour change. The firmness value of fruit became decrease and the value of pH was increase. (author)

  10. Systematization of efficiency correction for gamma-ray disk sources with semiconductor detectors

    International Nuclear Information System (INIS)

    Chatani, Hiroshi

    1999-01-01

    Full energy peak efficiency correction for disk sources has been systematically studied using the mapping method with two high-purity germanium detectors and two low-energy photon spectrometers. The following are found using only single-line (i.e., no coincidence summing loses) γ-rays: (1) The efficiency distributions on a plane parallel to the entrance window of semiconductor detectors is in perfect accord with Gaussian curves inside the circumference of the cylindrical Ge crystal, however, they deviate from the curves outside the circumference. (2) The width parameters of the Gaussian function fitted to the efficiency distributions have a systematic relationship with γ-ray energy. (3) The mapping method is of practical use and has satisfactory accuracy

  11. High-Resolution and -Efficiency Gamma-Ray Detection for the FRIB Decay Station

    Science.gov (United States)

    Grover, Hannah; Leach, Kyle; Natzke, Connor; FRIB Decay Station Collaboration Collaboration

    2017-09-01

    As we push our knowledge of nuclear structure to the frontier of the unknown with FRIB, a new high-efficiency, -resolution, and -sensitivity photon-detection device is critical. The FRIB Decay Station Collaboration is working to create a new detector array that meets the needs of the exploratory nature of FRIB by minimizing cost and maximizing efficiency. GEANT4 simulations are being utilized to combine detectors in various configurations to test their feasibility. I will discuss these simulations and how they compare to existing simulations of past-generation decay-spectroscopy equipment. This work has been funded by the DOE Office of Science, Office of Nuclear Physics.

  12. An evaluation study of research efficiency of the Guangzhou institute of respiratory diseases based on malmquist index.

    Science.gov (United States)

    Liao, Jian-Feng; Wang, Juan; Liang, Liang; Wu, Yong-Ding; Huang, Mei-Juan; Liu, Tian-Qiang; Zhou, Lin; Wang, Xin-Wang

    2016-10-01

    This study aimed to analyze the dynamic changes of the scientific research innovation efficiency of Guangzhou Institute of Respiratory Diseases (GIRD) during the year 2009-2013 to explore the reason for these changes and give some suggestions on how to improve the overall efficiency of the Institute. The panel data used in this study were taken from 19 research teams of GIRD during 2009 to 2013. Data envelopment analysis (DEA) based on Malmquist index (MI) was used to analyze the performance of each research team in terms of productivity changes over time. Data were analyzed using DEAP 2.1 software. The annual average increase rate of total factor productivity (TFP), technological progress, technical efficiency, pure technical efficiency, and scale efficiency was 30.4%, 22.5%, 6.4%, 0.9%, and 5.4%, respectively from 2009 to 2013. The scientific research innovation efficiency of the GIRD was generally high and kept on growing. The increase of TFP was mainly caused by the progress of tech, the descending of TFP in some teams should be mainly attributable to the declining pure technical efficiency, and scale efficiency on the whole, maintaining a stable growth at a low speed. To achieve higher scientific research innovation, GIRD not only needs to further improve the management level and introduce advanced management mode, but also needs to focus on optimization of resource allocation, as well as to strengthen the talent introduction, and continue to maintain the absorption of new technologies and innovation.

  13. High slope efficiency and high refractive index change in direct-written Yb-doped waveguide lasers with depressed claddings.

    Science.gov (United States)

    Palmer, Guido; Gross, Simon; Fuerbach, Alexander; Lancaster, David G; Withford, Michael J

    2013-07-15

    We report the first Yb:ZBLAN and Yb:IOG10 waveguide lasers fabricated by the fs-laser direct-writing technique. Pulses from a Titanium-Sapphire laser oscillator with 5.1 MHz repetition rate were utilized to generate negative refractive index modifications in both glasses. Multiple modifications were aligned in a depressed cladding geometry to create a waveguide. For Yb:ZBLAN we demonstrate high laser slope efficiency of 84% with a maximum output power of 170 mW. By using Yb:IOG10 a laser performance of 25% slope efficiency and 72 mW output power was achieved and we measured a remarkably high refractive index change exceeding Δn = 2.3 × 10(-2).

  14. The impact of ownership structure on bank productivity and efficiency: Evidence from semi-parametric Malmquist Productivity Index

    Directory of Open Access Journals (Sweden)

    Fadzlan Sufian

    2014-12-01

    Full Text Available The present study employs the state of the art bias-corrected Malmquist Productivity Index method to examine the sources of efficiency and productivity of the foreign and domestic banks operating in the Malaysian banking sector. The preferred methodology enables us to isolate efforts to catch up to the frontier (efficiency change from shifts in the frontier (technological change [TECHCH]. The results indicate that the Malaysian banking sector has exhibited productivity progress mainly attributed to technological progress. The empirical findings suggest that both the domestic and foreign banks have exhibited productivity progress albeit at different quantum attributed mainly to progress in TECHCH.

  15. AP Index

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Planetary Amplitude index - Bartels 1951. The a-index ranges from 0 to 400 and represents a K-value converted to a linear scale in gammas (nanoTeslas)--a scale that...

  16. Efficiency of Methanolic Extract of Gamma Irradiated Parsley as Antioxidant and Antimicrobial

    International Nuclear Information System (INIS)

    Abdeldaiem, M.H.; Ali, H.G.M.; Mohamed, E.A.

    2011-01-01

    Antioxidant and antimicrobial activities of methanolic extract of gamma irradiated parsley (Petroselinum crispum) at dose levels of 3, 6 and 9 kGy were determined, and the composition of methanolic extracts of non-irradiated and irradiated parsley were identified by GC-MS. The results showed that the methanolic extracts of non-irradiated and irradiated parsley had higher contents of total phenolic compounds and exhibited antioxidant of DPPH radical scavenging activity. Based on these results, the methanolic extracts of irradiated parsley at 6 kGy were selected for their higher activity as antioxidant as compared to other samples owing to their high content of total phenolic compounds and scavenging effect on DPPH radical. The analysis by GC-MS led to the identification of 23 and 24 components for non-irradiated and irradiated samples at 6 kGy, respectively. The main compound of the methanolic extract of non-irradiated parsley was acetic acid ethyl ester (28.5%). Meanwhile, the main compound of irradiated parsley at 6 kGy methanolic extract was phenol,2-methoxy-3(27.3 %). The antibacterial effect of methanolic extract of non-irradiated and irradiated parsley and the minimum inhibitory concentration (MIC) values were assayed. The methanolic extract of irradiated parsley (6 kGy) was generally more effective against tested bacterial strains than the extract of non-irradiated parsley. The study exhibited that gram- negative bacteria under study were more sensitive than gram-positive one. The MIC values of tested bacteria of the methanolic extract of irradiated parsley (6 kGy) were in the range 4 to 20 μg/ml. It could be concluded that the methanolic extract of parsley can be used in food industry as natural food additive and in particular that extract from irradiated parsley at 6 kGy

  17. Evaluation of efficiency of a semiconductor gamma camera eZ-SCOPE AN

    International Nuclear Information System (INIS)

    Wang Xinqiang; Wang Wei; Zhu Jiarui; Zhao Wenrui

    2004-01-01

    Objective: To study the basic performance of a compact semiconductor gamma camera (eZ-SCOPE AN) which is constructed using cadmium zinc telluride (CdZnTe) detectors with identical numbers of pixels. Each of the semiconductors sized 2 mm x 2 mm is located in 16 matrix x 16 matrix. The view field is 32 mm x 32 mm. Methods: Using a quality-control phantom, the eZ-SCOPE AN was evaluated. The specific performance characteristics were evaluated as shown below referring to National Electrical Manufacturers Association (NEMA) standards. 1) Intrinsic energy resolution. 2) Intrinsic count rate performance 3) Integral uniformity. 4) System planar sensitivity. 5) Special system resolution. Results: The intrinsic energy resolution [full width at half maximum (FWHM)] was 5.07%. It was failed to determine the maximal intrinsic count rate and the 20% count loss rate with a point source of 37 MBq because the plateau was not reached while using the solutions measured. The integral uniformity was 3.84% with the high sensitivity collimator. The system planer sensitivity was 20 988 counts·min -1 ·MBq -1 with high resolution collimator and 61 090 counts·min -1 ·MBq -1 with high sensitivity collimator. The special system resolution (FWHM) was 2.2 mm when the distance between the source and the collimator was 0 mm and it was 5.7 mm when the distance was 30 mm. Conclusion: This device is of high resolution and high sensitivity and is a reliable tool to investigate radioactivity biodistribution in small organs and small animals. (authors)

  18. INDEXING AND INDEX FUNDS

    Directory of Open Access Journals (Sweden)

    HAKAN SARITAŞ

    2013-06-01

    Full Text Available Proponents of the efficient market hypothesis believe that active portfolio management is largely wasted effort and unlikely to justify the expenses incurred. Therefore, they advocate a passive investment strategy that makes no attempt to outsmart the market. One common strategy for passive management is indexing where a fund is designed to replicate the performance of a broad-based index of stocks and bonds. Traditionally, indexing was used by institutional investors, but today, the use of index funds proliferated among individual investors. Over the years, both international and domestic index funds have disproportionately outperformed the market more than the actively managed funds have.

  19. THE RADIATIVE X-RAY AND GAMMA-RAY EFFICIENCIES OF ROTATION-POWERED PULSARS

    International Nuclear Information System (INIS)

    Vink, Jacco; Bamba, Aya; Yamazaki, Ryo

    2011-01-01

    We present a statistical analysis of the X-ray luminosity of rotation-powered pulsars and their surrounding nebulae using the sample of Kargaltsev and Pavlov, and we complement this with an analysis of the γ-ray emission of Fermi-detected pulsars. We report a strong trend in the efficiency with which spin-down power is converted to X-ray and γ-ray emission with characteristic age: young pulsars and their surrounding nebulae are efficient X-ray emitters, whereas in contrast old pulsars are efficient γ-ray emitters. We divided the X-ray sample in a young (τ c 4 yr) and old sample and used linear regression to search for correlations between the logarithm of the X-ray and γ-ray luminosities and the logarithms of the periods and period derivatives. The X-ray emission from young pulsars and their nebulae are both consistent with L X ∝ P-dot 3 /P 6 . For old pulsars and their nebulae the X-ray luminosity is consistent with a more or less constant efficiency η≡L X / E-dot rot ∼8x10 -5 . For the γ-ray luminosity we confirm that L γ ∝ √E-dot rot . We discuss these findings in the context of pair production inside pulsar magnetospheres and the striped wind model. We suggest that the striped wind model may explain the similarity between the X-ray properties of the pulsar wind nebulae and the pulsars themselves, which according to the striped wind model may both find their origin outside the light cylinder, in the pulsar wind zone.

  20. The Radiative X-ray and Gamma-ray Efficiencies of Rotation-powered Pulsars

    Science.gov (United States)

    Vink, Jacco; Bamba, Aya; Yamazaki, Ryo

    2011-02-01

    We present a statistical analysis of the X-ray luminosity of rotation-powered pulsars and their surrounding nebulae using the sample of Kargaltsev & Pavlov, and we complement this with an analysis of the γ-ray emission of Fermi-detected pulsars. We report a strong trend in the efficiency with which spin-down power is converted to X-ray and γ-ray emission with characteristic age: young pulsars and their surrounding nebulae are efficient X-ray emitters, whereas in contrast old pulsars are efficient γ-ray emitters. We divided the X-ray sample in a young (τ c < 1.7 × 104 yr) and old sample and used linear regression to search for correlations between the logarithm of the X-ray and γ-ray luminosities and the logarithms of the periods and period derivatives. The X-ray emission from young pulsars and their nebulae are both consistent with L_X ∝ \\dot{P}^3/P^6. For old pulsars and their nebulae the X-ray luminosity is consistent with a more or less constant efficiency η ≡ L_X/\\dot{E}_{rot} ≈ 8× 10^{-5}. For the γ-ray luminosity we confirm that L_γ ∝ √{\\dot{E}_{rot}}. We discuss these findings in the context of pair production inside pulsar magnetospheres and the striped wind model. We suggest that the striped wind model may explain the similarity between the X-ray properties of the pulsar wind nebulae and the pulsars themselves, which according to the striped wind model may both find their origin outside the light cylinder, in the pulsar wind zone.

  1. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  2. Efficient Forest Fire Detection Index for Application in Unmanned Aerial Systems (UASs

    Directory of Open Access Journals (Sweden)

    Henry Cruz

    2016-06-01

    Full Text Available This article proposes a novel method for detecting forest fires, through the use of a new color index, called the Forest Fire Detection Index (FFDI, developed by the authors. The index is based on methods for vegetation classification and has been adapted to detect the tonalities of flames and smoke; the latter could be included adaptively into the Regions of Interest (RoIs with the help of a variable factor. Multiple tests have been performed upon database imagery and present promising results: a detection precision of 96.82% has been achieved for image sizes of 960 × 540 pixels at a processing time of 0.0447 seconds. This achievement would lead to a performance of 22 f/s, for smaller images, while up to 54 f/s could be reached by maintaining a similar detection precision. Additional tests have been performed on fires in their early stages, achieving a precision rate of p = 96.62%. The method could be used in real-time in Unmanned Aerial Systems (UASs, with the aim of monitoring a wider area than through fixed surveillance systems. Thus, it would result in more cost-effective outcomes than conventional systems implemented in helicopters or satellites. UASs could also reach inaccessible locations without jeopardizing people’s safety. On-going work includes implementation into a commercially available drone.

  3. Effects of commercial doses of {gamma}-irradiation on DVI (Dormancy overcoming Visual Index) of red garlic clove (Allium sativum L.)

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, C.N.; Mujica, M.B.; Orioli, G.A. [Universidad Nacional del Sur, Bahia Blanca (Argentina). Dept. de Agronomia; Croci, C.A. [Universidad Nacional del Sur, Bahia Blanca (Argentina). Lab. de Radioisotopos

    1995-12-31

    The growth inhibitor effect of commercial doses of gamma rays was analyzed on the DVI evolution during garlic post-harvest storage. The DVI behaviour of irradiated and non-irradiated samples was identical throughout the rest period (90 d.p.h.) and the beginning of sprouting (120 d.p.h.). At 180 d.p.h. non-irradiated samples showed a sharp increase of DVI, reaching the maximum value at 240 d.p.h. At the same time irradiated samples only showed a slight index increase, hardly reaching 60%. These results are discussed in relation to the use of DVI as a possible indicator of irradiation treatment on garlic bulbs. (author). 9 refs, 3 figs.

  4. A simple and reliable method to detect gamma irradiated lentil (Lens culinaris Medik.) seeds by germination efficiency and seedling growth test

    International Nuclear Information System (INIS)

    Chaudhuri, Sadhan K.

    2002-01-01

    Germination efficiency and root/shoot length of germinated seedling is proposed to identify irradiated lentil seeds. Germination percentage was reduced above 0.2 kGy and lentil seeds were unable to germinate above 1.0 kGy dose. The critical dose that prevented the root elongation varied from 0.1 to 0.5 kGy. The sensitivity of lentil seeds to gamma irradiation was inversely proportional to moisture content of the seeds. Radiation effects could be detected in seeds even 12 months storage after gamma irradiation

  5. Efficiency of pre-sowing gamma-irradiation of tomato seeds under conditions of protected ground and under the effect of mineral fertilizers

    International Nuclear Information System (INIS)

    Pogosyan, G.S.; Avakyan, A.G.; Semerdzhyan, S.P.

    1983-01-01

    Efficiency of pre-sowing gamma-irradiation of seeds on yield capacity and other practical and biological criteria of hothouse fertilized tomatoes has been studied. It is shown that pre-sowing gamma-irradiation of seeds increases the output of early production and total crop. It is suggested to use in production the irradiation of seeds in the dose of 12 Gr cultivating tomatoes on the background of N 240 P 240 K 240 and in the dose of 5 Gr on the ground of N 120 P 120 K 120 fertilizers

  6. Do forwarders improve sustainability efficiency? : Evidence from a European DEA Malmquist index calculation

    NARCIS (Netherlands)

    Klumpp, Matthias

    2017-01-01

    Sustainability performance and efficiency is an important topic in transportation and for forwarders. This is shown, for example, by the fact that major logistics service providers LSP publish sustainability reports, often within the annual legal business report. However, in depth research is

  7. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples

    International Nuclear Information System (INIS)

    Baccouche, S.; Al-Azmi, D.; Karunakara, N.; Trabelsi, A.

    2012-01-01

    Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. Two scintillation detectors were studied in this work; CsI(Tl) and NaI(Tl) with identical size for measurement of terrestrial samples for performance study. This work describes a Monte Carlo method for making the full-energy efficiency calibration curves for both detectors using gamma-ray energies associated with the decay of naturally occurring radionuclides 137 Cs (661 keV), 40 K (1460 keV), 238 U ( 214 Bi, 1764 keV) and 232 Th ( 208 Tl, 2614 keV), which are found in terrestrial samples. The magnitude of the coincidence summing effect occurring for the 2614 keV emission of 208 Tl is assessed by simulation. The method provides an efficient tool to make the full-energy efficiency calibration curve for scintillation detectors for any samples geometry and volume in order to determine accurate activity concentrations in terrestrial samples. - Highlights: ► CsI (Tl) and NaI (Tl) detectors were studied for the measurement of terrestrial samples. ► Monte Carlo method was used for efficiency calibration using natural gamma emitting terrestrial radionuclides. ► The coincidence summing effect occurring for the 2614 keV emission of 208 Tl is assessed by simulation.

  8. Methods of formation of efficiency indexes of electric power sources integration in regional electric power systems

    International Nuclear Information System (INIS)

    Marder, L.I.; Myzin, A.I.

    1993-01-01

    A methodic approach to the grounding of the integration process efficiency within the Unified electric power system is given together with the selection of a rational areal structure and concentration of power-generating source capacities. Formation of an economic functional according to alternative scenavies including the cost components taking account of the regional interests is considered. A method for estimation and distribution of the effect from electric power production integration in the power systems under new economic conditions is proposed

  9. Lamp-Ballast Compatibility Index for Efficient Ceramic Metal Halide Lamp Operation

    OpenAIRE

    Sourish Chatterjee

    2013-01-01

    Development of energy efficient products and exploration of energy saving potential are major challenges for present day’s technology. Ceramic Metal Halide lamp is the latest improved version of metal halide lamp that finds its wide applications in indoor commercial lighting especially in retail shop lighting. This lamp shows better performance in terms of higher lumen per watt and colour constancy in comparison to conventional metal halide lamp. The inherent negative incremental impedance of...

  10. CHex: An Efficient RDF Storage and Indexing Scheme for Column-Oriented Databases

    OpenAIRE

    Xin Wang; Shuyi Wang; Pufeng Du; Zhiyong Feng

    2011-01-01

    As increasingly large RDF data sets are being published on the Web, effcient RDF data management has become an essential factor in realizing the Semantic Web vision. However, most existing RDF storage schemes, which are built on top of row-store relational databases, are constrained in terms of efficiency and scalability. Still, the growing popularity of the RDF format used in real-world applications arguably calls for an effort to deal with these drawbacks. In this paper, we propose a novel ...

  11. A simple and efficient methodology to improve geometric accuracy in gamma knife radiation surgery: implementation in multiple brain metastases.

    Science.gov (United States)

    Karaiskos, Pantelis; Moutsatsos, Argyris; Pappas, Eleftherios; Georgiou, Evangelos; Roussakis, Arkadios; Torrens, Michael; Seimenis, Ioannis

    2014-12-01

    To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, "average" image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energies

    International Nuclear Information System (INIS)

    Szymanska, K.; Achenbach, P.; Agnello, M.; Botta, E.; Bracco, A.; Bressani, T.; Camera, F.; Cederwall, B.; Feliciello, A.; Ferro, F.; Gerl, J.; Iazzi, F.; Kavatsyuk, M.; Kojouharov, I.; Pochodzalla, J.; Raciti, G.; Saito, T.R.; Sanchez Lorente, A.; Tegner, P.-E.; Wieland, O.

    2008-01-01

    The use of High Purity Germanium detectors (HPGe) has been planned in some future experiments of hadronic physics. The crystals will be located close to large spectrometers where the magnetic fringing field will not be negligible and their performances might change. Moreover high precision is required in these experiments. The contribution of magnetic field presence and long term measurements is unique. In this paper the results of systematic measurements of the resolution, stability and efficiency of a crystal operating inside a magnetic field of 0.8 T, using radioactive sources in the energy range from 0.08 to 1.33 MeV, are reported. The measurements have been repeated during several months in order to test if any permanent damage occurred. The resolution at 1.117 and 1.332 MeV gamma-rays from a 60 Co source has been measured at different magnetic fields in the range of 0-0.8 T and the results are compared with the previous data

  13. Design and environmental applications of an ultra-low-background, high-efficiency intrinsic Ge gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1981-04-01

    A coincidence shielded intrinsic Ge gamma-ray spectrometer incorporating a 25% efficient, high resolution coaxial diode inside a 30 cm diameter NaI(Tl) shield is described. System design eliminates the major cause of background and minimizes cosmic-ray created background events through the use of electronic means. The system provides a peak-to-Compton ratio of greater than 1000 to 1 for 137 Cs and high sensitivity for both low and high level radionuclide measurements. At 3 MeV the background is 0.000058 counts per minute per keV. At 1 MeV it is 0.00048 counts per minute per keV, and at 0.5 MeV it is 0.0045 counts per minute per keV. Traces of primordial radionuclides create background events such as at 2.614 MeV (0.016 counts per minute total peak area), at 2.448 MeV (0.0058 counts per minute per total peak area), and at 2.204 MeV (0.023 counts per minute per total peak area). The system is discussed with respect to its background design, methods to improve its design, and its application to measurements of neutron activated and environmental materials problems

  14. Evaluation of transpiration properties of wall greening using evaporation efficiency rate as an index

    International Nuclear Information System (INIS)

    Suzuki, H.; Misaka, I.; Tashiro, Y.

    2007-01-01

    In this study, the evaporation efficiency, which is a heat balance parameter necessary for numerical simulation of greening effects, was derived in order quantitatively to evaluate the effects of wall greening panels on improving the thermal environment. The efficiency was determined by monitoring the amount of evapotranspiration from wall greening panels on which either Hedera helix or Euonymus fortunei was planted, calculating the sensible heat-flux from SAT measurements, and determining the convective heat transfer rate, material transfer rate and the difference between the measured and calculated amounts of evapotranspiration. The results showed that: 1) both the convection heat transfer rate and material transfer rate were highly correlated to wind speed, and the derived equations for calculating the rates were functions of wind speed, 2) the mean evaporation efficiency for the monitoring period was 0.25 for Hedera helix and 0.26 for Euonymus fortunei, and 3) the amounts of evaporation from the wall greening panels tested were 4 to 5 mm for both plant species and showed correlations to daily cumulative irradiation

  15. Efficient One-Pot Synthesis of Colloidal Zirconium Oxide Nanoparticles for High-Refractive-Index Nanocomposites.

    Science.gov (United States)

    Liu, Chao; Hajagos, Tibor Jacob; Chen, Dustin; Chen, Yi; Kishpaugh, David; Pei, Qibing

    2016-02-01

    Zirconium oxide nanoparticles are promising candidates for optical engineering, photocatalysis, and high-κ dielectrics. However, reported synthetic methods for the colloidal zirconium oxide nanoparticles use unstable alkoxide precursors and have various other drawbacks, limiting their wide application. Here, we report a facile one-pot method for the synthesis of colloidally stable zirconium oxide nanoparticles. Using a simple solution of zirconium trifluoroacetate in oleylamine, highly stable zirconium oxide nanoparticles have been synthesized with high yield, following a proposed amidization-assisted sol-gel mechanism. The nanoparticles can be readily dispersed in nonpolar solvents, forming a long-term stable transparent solution, which can be further used to fabricate high-refractive-index nanocomposites in both monolith and thin-film forms. In addition, the same method has also been extended to the synthesis of titanium oxide nanoparticles, demonstrating its general applicability to all group IVB metal oxide nanoparticles.

  16. Geostatistics for Mapping Leaf Area Index over a Cropland Landscape: Efficiency Sampling Assessment

    Directory of Open Access Journals (Sweden)

    Javier Garcia-Haro

    2010-11-01

    Full Text Available This paper evaluates the performance of spatial methods to estimate leaf area index (LAI fields from ground-based measurements at high-spatial resolution over a cropland landscape. Three geostatistical model variants of the kriging technique, the ordinary kriging (OK, the collocated cokriging (CKC and kriging with an external drift (KED are used. The study focused on the influence of the spatial sampling protocol, auxiliary information, and spatial resolution in the estimates. The main advantage of these models lies in the possibility of considering the spatial dependence of the data and, in the case of the KED and CKC, the auxiliary information for each location used for prediction purposes. A high-resolution NDVI image computed from SPOT TOA reflectance data is used as an auxiliary variable in LAI predictions. The CKC and KED predictions have proven the relevance of the auxiliary information to reproduce the spatial pattern at local scales, proving the KED model to be the best estimator when a non-stationary trend is observed. Advantages and limitations of the methods in LAI field predictions for two systematic and two stratified spatial samplings are discussed for high (20 m, medium (300 m and coarse (1 km spatial scales. The KED has exhibited the best observed local accuracy for all the spatial samplings. Meanwhile, the OK model provides comparable results when a well stratified sampling scheme is considered by land cover.

  17. Management model of productive capacity: integrating theory of constraints and the global operational efficiency index (IROG

    Directory of Open Access Journals (Sweden)

    Diego Augusto Pacheco

    2012-08-01

    Full Text Available This paper presents a model of management capacity in productive systems integrating the concepts of the Theory of Constraints and Total Productive Maintenance (TPM. The main objective of this study is to discuss and propose a model of management capacity, able to answer the following key questions: i capacity indicators which should be considered and how to measure them to measure the productive capacity of manufacturing systems? ii what is the real productive capacity of the system analyzed under a determined relationship between capacity and demand? The discussion of the proposed model is relevant because the definition of productive capacity system enables better management of resources and capabilities, improve production scheduling on the factory floor and meeting the demands imposed by the market. This paper presents the proposition of using the Operating Income Index Global (IROG with a different approach from traditional literature dealing with the theme, presented by Nakajima (1988. The results of this paper enable to develop a model to determine the capacity of the production system and the impact on the productive capacity of the entire system, not to consider the quality conformances that occur after the bottleneck resource of the production flow.

  18. Efficiency of Pollution Tolerance Index (PTI of macroinvertebrates in detecting aquatic pollution in an oxbow lake in India

    Directory of Open Access Journals (Sweden)

    Dipankar Ghosh

    2017-11-01

    Full Text Available This paper evaluates the efficiency of a macroinvertebrate-based Pollution Tolerance Index (PTI in detecting aquatic pollution in the Chhariganga oxbow lake in India. In this lake, calculated PTIs were compared with results from an array of physicochemical water and sediment parameters and to a macroinvertebrate diversity assessment conducted in parallel for the same lake. The obtained PTI values fell in a range (between 20 and 31 that are indicative of an absence of organic pollution according to the literature, and are normally reported for systems devoid of anthropogenic activity (for instance no monsoonal polluting jute retting activities. However, in the light of the results for the assessed water and sediment physicochemical parameters, and the support of diversity indexes of macroinvertebrates, using data from the same lake, it was possible to conclude that the obtained PTI values do not reflect the true pollution status of this oxbow lake. As PTI values and diversity indexes contradict each other in detecting pollution, it is advised to take both parameters into consideration when using macroinvertebrates to assess aquatic health.

  19. The ratio of nurse consultation and physician efficiency index of senior rheumatologists is significantly higher than junior physicians in rheumatology residency training

    DEFF Research Database (Denmark)

    Emamifar, Amir; van Bui Hansen, Morten Hai; Jensen Hansen, Inger Marie

    2017-01-01

    To elucidate the difference between ratios of nurse consultation sought by senior rheumatologists and junior physicians in rheumatology residency training, and also to evaluate physician efficiency index respecting patients with rheumatoid arthritis (RA). Data regarding outpatient visits for RA...... patients between November 2013 and 2015 were extracted. The mean interval (day) between consultations, the nurse/physician visits ratio, and physician efficiency index (nurse/physician visits ratio × mean interval) for each senior and junior physicians were calculated. Disease Activity Score in 28 joints....../physician visits ratio (P = .01) and mean efficiency index (P = .04) of senior rheumatologists were significantly higher than that of junior physicians. Regression analysis showed a positive correlation between physician postgraduate experience and physician efficiency index adjusted for DAS28 at baseline...

  20. The efficiency calibration and development of environmental correction factors for an in situ high-resolution gamma spectroscopy well logging system

    International Nuclear Information System (INIS)

    Giles, J.R.

    1996-05-01

    A Gamma Spectroscopy Logging System (GSLS) has been developed to study sub-surface radionuclide contamination. Absolute efficiency calibration of the GSLS was performed using simple cylindrical borehole geometry. The calibration source incorporated naturally occurring radioactive material (NORM) that emitted photons ranging from 186-keV to 2,614-keV. More complex borehole geometries were modeled using commercially available shielding software. A linear relationship was found between increasing source thickness and relative photon fluence rates at the detector. Examination of varying porosity and moisture content showed that as porosity increases, relative photon fluence rates increase linearly for all energies. Attenuation effects due to iron, water, PVC, and concrete cylindrical shields were found to agree with previous studies. Regression analyses produced energy-dependent equations for efficiency corrections applicable to spectral gamma-ray well logs collected under non-standard borehole conditions

  1. A Simple and Efficient Methodology To Improve Geometric Accuracy in Gamma Knife Radiation Surgery: Implementation in Multiple Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Karaiskos, Pantelis, E-mail: pkaraisk@med.uoa.gr [Medical Physics Laboratory, Medical School, University of Athens (Greece); Gamma Knife Department, Hygeia Hospital, Athens (Greece); Moutsatsos, Argyris; Pappas, Eleftherios; Georgiou, Evangelos [Medical Physics Laboratory, Medical School, University of Athens (Greece); Roussakis, Arkadios [CT and MRI Department, Hygeia Hospital, Athens (Greece); Torrens, Michael [Gamma Knife Department, Hygeia Hospital, Athens (Greece); Seimenis, Ioannis [Medical Physics Laboratory, Medical School, Democritus University of Thrace, Alexandroupolis (Greece)

    2014-12-01

    Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.

  2. Testing for Environmental Kuznets Curve in the EU Agricultural Sector through an Eco-(inEfficiency Index

    Directory of Open Access Journals (Sweden)

    George Vlontzos

    2017-12-01

    Full Text Available Studies on agricultural production practices advance within international literature and new methods are proposed in order to assess the agricultural sustainability, either at farm or macro level. The present paper builds on these advancements and develops a synthetic Eco-(inefficiency index by employing a directional distance function—data envelopment analysis (DEA model. This index is used in order to assess the sustainability of the EU agricultural sector for the period 1999–2012 on a country level. Furthermore, Eco-(inefficiency, together with the energy use and greenhouse gas (GHG emissions are regressed on the gross domestic product (GDP of EU countries, in order to check for any environmental Kuznets curve relationship existence. Results signify that efficiency improvements are possible, both towards output development and GHG emissions reduction. In addition, the potential of each country in adopting more sustainable production practices is not totally connected with its economic development, as Eco-(inefficiency and GDP levels of EU countries seem to be linked with an N-Shaped curve.

  3. Efficient and Robust Detection of GFSK Signals under Dispersive Channel, Modulation Index, and Carrier Frequency Offset Conditions

    Directory of Open Access Journals (Sweden)

    Stephan Weiss

    2005-09-01

    Full Text Available Gaussian frequency shift keying is the modulation scheme specified for Bluetooth. Signal adversities typical in Bluetooth networks include AWGN, multipath propagation, carrier frequency, and modulation index offsets. In our effort to realise a robust but efficient Bluetooth receiver, we adopt a high-performance matched-filter-based detector, which is near optimal in AWGN, but requires a prohibitively costly filter bank for processing of K bits worth of the received signal. However, through filtering over a single bit period and performing phase propagation of intermediate results over successive single-bit stages, we eliminate redundancy involved in providing the matched filter outputs and reduce its complexity by up to 90% (for K=9. The constant modulus signal characteristic and the potential for carrier frequency offsets make the constant modulus algorithm (CMA suitable for channel equalisation, and we demonstrate its effectiveness in this paper. We also introduce a stochastic gradient-based algorithm for carrier frequency offset correction, and show that the relative rotation between successive intermediate filter outputs enables us to detect and correct offsets in modulation index.

  4. Photochemical Reflectance Index (PRI) as a proxy of Light Use Efficiency (LUE) and transpiration in Mediterranean crop sites

    Science.gov (United States)

    LE Dantec, V.; Chebbi, W.; Boulet, G.; Merlin, O.; Lili-Chabaane, Z.; Er Raki, S.; Ceschia, E.; Khabba, S.; Fanise, P.; Zawilski, B.; Simonneaux, V.; Jarlan, L.

    2016-12-01

    The Photochemical Reflectance Index (PRI) is based on the short term reversible xanthophyll pigment changes accompanying plant stress and therefore of the associated photosynthetic activities. Strong relationships between PRI and Light Use Efficiency (LUE) were shown at leaf and canopy scales and over a wide range of species (Garbulsky et al., 2011). But very few previous works have explored the potential link with plant water status. In this study, we have first analyzed the link between PRI and LUE at canopy scale on two different crops in terms of canopy structure and crop management: olive grove (Tunisia) and wheat grown under different water regimes (irrigated or rainfed) and climate zones (France, Morocco). We have investigated the daily and seasonal dynamics of PRI; linking its variations to meteorological factors (global radiation and sun angle effects, soil water content, relative air humidity …) and plant processes. The highest correlations were mainly observed in clear skies conditions. We have found, whatever site, linear negative relationships between PRI and LUE using data acquired in midday (i.e. in solar zenithal angle condition). Linear link between PRI and sapflow measurements was also revealed. This correlation was obtained over periods characterized by a moderate soil water deficit, i.e. by when transpiration rate was mainly control by Vapor Pressure Deficit. We will then briefly presented alternative and complementary approaches to this index, to detect different level of water stress using thermal infrared emissions.

  5. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples

    Energy Technology Data Exchange (ETDEWEB)

    Baccouche, S., E-mail: souad.baccouche@cnstn.rnrt.tn [UR-MDTN, National Center for Nuclear Sciences and Technology, Technopole Sidi Thabet, 2020 Sidi Thabet (Tunisia); Al-Azmi, D., E-mail: ds.alazmi@paaet.edu.kw [Department of Applied Sciences, College of Technological Studies, Public Authority for Applied Education and Training, Shuwaikh, P.O. Box 42325, Code 70654 (Kuwait); Karunakara, N., E-mail: karunakara_n@yahoo.com [University Science Instrumentation Centre, Mangalore University, Mangalagangotri 574199 (India); Trabelsi, A., E-mail: adel.trabelsi@fst.rnu.tn [UR-MDTN, National Center for Nuclear Sciences and Technology, Technopole Sidi Thabet, 2020 Sidi Thabet (Tunisia); UR-UPNHE, Faculty of Sciences of Tunis, El-Manar University, 2092 Tunis (Tunisia)

    2012-01-15

    Gamma-ray measurements in terrestrial/environmental samples require the use of high efficient detectors because of the low level of the radionuclide activity concentrations in the samples; thus scintillators are suitable for this purpose. Two scintillation detectors were studied in this work; CsI(Tl) and NaI(Tl) with identical size for measurement of terrestrial samples for performance study. This work describes a Monte Carlo method for making the full-energy efficiency calibration curves for both detectors using gamma-ray energies associated with the decay of naturally occurring radionuclides {sup 137}Cs (661 keV), {sup 40}K (1460 keV), {sup 238}U ({sup 214}Bi, 1764 keV) and {sup 232}Th ({sup 208}Tl, 2614 keV), which are found in terrestrial samples. The magnitude of the coincidence summing effect occurring for the 2614 keV emission of {sup 208}Tl is assessed by simulation. The method provides an efficient tool to make the full-energy efficiency calibration curve for scintillation detectors for any samples geometry and volume in order to determine accurate activity concentrations in terrestrial samples. - Highlights: Black-Right-Pointing-Pointer CsI (Tl) and NaI (Tl) detectors were studied for the measurement of terrestrial samples. Black-Right-Pointing-Pointer Monte Carlo method was used for efficiency calibration using natural gamma emitting terrestrial radionuclides. Black-Right-Pointing-Pointer The coincidence summing effect occurring for the 2614 keV emission of {sup 208}Tl is assessed by simulation.

  6. Proton/gamma relative thermoluminescence efficiencies of LiF:Mg,Cu,P+PTFE prepared at ININ and TLD-100H

    International Nuclear Information System (INIS)

    Avila, O.; Gonzalez, P.; Murillo, G.

    2009-10-01

    Properties of LiF:Mg,Cu,P+PTFE dosemeters developed at ININ have been investigated in order to evaluate their performance compared to those of equivalent commercial dosemeters. In this work both LiF:Mg,Cu,P+PTFE and TLD-100H pellets were exposed to low fluence 3 MeV protons and to low dose gamma radiation to evaluate experimental proton/gamma efficiencies. Gamma irradiation was performed using the Vic krad irradiator at ININ at varying doses between 25 and 500 mGy. For proton irradiation the Tandem Van de Graaff accelerator at ININ was used. Dosemeters were placed on a holder inside a scattering chamber where protons impinge on a gold target and scatter in all directions. The holder allows for several angular positions so that dosemeters receive proton fluence between 10 6 and 10 1 0 p/cm 2 . Experimental efficiency values found for LiF:Mg,Cu,P+PTFE and TLD-100H were 0.18 +- 03 and 0.23 +- 0.03, respectively. These results allow to confirm the reliability of the dosemeters developed at ININ. (Author)

  7. Identification of high-efficiency 3′GG gRNA motifs in indexed FASTA files with ngg2

    Directory of Open Access Journals (Sweden)

    Elisha D. Roberson

    2015-11-01

    Full Text Available CRISPR/Cas9 is emerging as one of the most-used methods of genome modification in organisms ranging from bacteria to human cells. However, the efficiency of editing varies tremendously site-to-site. A recent report identified a novel motif, called the 3′GG motif, which substantially increases the efficiency of editing at all sites tested in C. elegans. Furthermore, they highlighted that previously published gRNAs with high editing efficiency also had this motif. I designed a Python command-line tool, ngg2, to identify 3′GG gRNA sites from indexed FASTA files. As a proof-of-concept, I screened for these motifs in six model genomes: Saccharomyces cerevisiae, Caenorhabditis elegans, Drosophila melanogaster, Danio rerio, Mus musculus, and Homo sapiens. I also scanned the genomes of pig (Sus scrofa and African elephant (Loxodonta africana to demonstrate the utility in non-model organisms. I identified more than 60 million single match 3′GG motifs in these genomes. Greater than 61% of all protein coding genes in the reference genomes had at least one unique 3′GG gRNA site overlapping an exon. In particular, more than 96% of mouse and 93% of human protein coding genes have at least one unique, overlapping 3′GG gRNA. These identified sites can be used as a starting point in gRNA selection, and the ngg2 tool provides an important ability to identify 3′GG editing sites in any species with an available genome sequence.

  8. Association between body mass index and arsenic methylation efficiency in adult women from southwest U.S. and northwest Mexico

    International Nuclear Information System (INIS)

    Gomez-Rubio, Paulina; Roberge, Jason; Arendell, Leslie; Harris, Robin B.; O'Rourke, Mary K.; Chen, Zhao; Cantu-Soto, Ernesto; Meza-Montenegro, Maria M.; Billheimer, Dean; Lu Zhenqiang; Klimecki, Walter T.

    2011-01-01

    Human arsenic methylation efficiency has been consistently associated with arsenic-induced disease risk. Interindividual variation in arsenic methylation profiles is commonly observed in exposed populations, and great effort has been put into the study of potential determinants of this variability. Among the factors that have been evaluated, body mass index (BMI) has not been consistently associated with arsenic methylation efficiency; however, an underrepresentation of the upper BMI distribution was commonly observed in these studies. This study investigated potential factors contributing to variations in the metabolism of arsenic, with specific interest in the effect of BMI where more than half of the population was overweight or obese. We studied 624 adult women exposed to arsenic in drinking water from three independent populations. Multivariate regression models showed that higher BMI, arsenic (+ 3 oxidation state) methyltransferase (AS3MT) genetic variant 7388, and higher total urinary arsenic were significantly associated with low percentage of urinary arsenic excreted as monomethylarsonic acid (%uMMA) or high ratio between urinary dimethylarsinic acid and uMMA (uDMA/uMMA), while AS3MT genetic variant M287T was associated with high %uMMA and low uDMA/uMMA. The association between BMI and arsenic methylation efficiency was also evident in each of the three populations when studied separately. This strong association observed between high BMI and low %uMMA and high uDMA/uMMA underscores the importance of BMI as a potential arsenic-associated disease risk factor, and should be carefully considered in future studies associating human arsenic metabolism and toxicity.

  9. Methods for fitting of efficiency curves obtained by means of HPGe gamma rays spectrometers; Metodos de ajuste de curvas de eficiencia obtidas por meio de espectrometros de HPGe

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Vanderlei

    2002-07-01

    The present work describes a few methodologies developed for fitting efficiency curves obtained by means of a HPGe gamma-ray spectrometer. The interpolated values were determined by simple polynomial fitting and polynomial fitting between the ratio of experimental peak efficiency and total efficiency, calculated by Monte Carlo technique, as a function of gamma-ray energy. Moreover, non-linear fitting has been performed using a segmented polynomial function and applying the Gauss-Marquardt method. For the peak area obtainment different methodologies were developed in order to estimate the background area under the peak. This information was obtained by numerical integration or by using analytical functions associated to the background. One non-calibrated radioactive source has been included in the curve efficiency in order to provide additional calibration points. As a by-product, it was possible to determine the activity of this non-calibrated source. For all fittings developed in the present work the covariance matrix methodology was used, which is an essential procedure in order to give a complete description of the partial uncertainties involved. (author)

  10. Effect of gamma irradiation, evaporation retardants and transpiration suppressants on grain yield, nutrient uptake and moisture-use efficiency on bread wheat (Triticum aestivum)

    International Nuclear Information System (INIS)

    Dash, D.K.; Sen, Avijit; Misra, N.M.

    1988-01-01

    A field trial was conducted on 'Malaviya 37' bread wheat (Triticum aestivum Linn. emend. Fiori and Paol.) in 1982-83 and 1983-84. It included 4 dos es of gamma irradiation of seeds (0, 2.5, 4.5 and 6.5 kR) and 5 treatments of evaporation retardants and transpiration suppressants, viz. control, rice (Oryza sativa Linn.) straw, wheat straw, rice straw + phenyl mercuric acetate (150 ppm) and wheat straw + kaolin (6 per cent). Seed irradiation with gamma-rays at 6.5 kR and wheat straw + kaolin gave 11.76 and 61.37 per cent higher yield than the control respectively. For moisture-use efficiency and NPK uptake these treatments also showed the same trend. (author). 12 refs

  11. An easy and efficient method to produce {gamma}-amino alcohols by reduction of {beta}-enamino ketones

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Maria Ines N.C.; Braga, Antonio C.H. [Universidade Estadual de Campinas, SP (Brazil). Inst. de Quimica]. E-mail: herrera@iqm.unicamp.br

    2004-12-01

    Reduction of {beta}-enamino ketones 2 with NaBH{sub 4} in glacial acetic acid gave {gamma}-amino alcohols 1 in 70% to 98% yield with diastereomeric excesses, preferentially the syn product, from 44% to 90%. The stereochemistry of these compounds was confirmed by analysis of their tetrahydro-1,3-oxazine derivatives 3. (author)

  12. EXILL - a high-efficiency, high-resolution setup for gamma-spectroscopy at an intense cold neutron beam facility

    Czech Academy of Sciences Publication Activity Database

    Jentschel, M.; Blanc, A.; de France, G.; Koster, U.; Leoni, S.; Mutti, P.; Simpson, G. S.; Krtička, M.; Tomandl, Ivo; Valenta, S.

    2017-01-01

    Roč. 12, č. 11 (2017), č. článku P11003. ISSN 1748-0221 Institutional support: RVO:61389005 Keywords : instrumentation for neutron sources * gamma detectors * spectrometers Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Nuclear physics Impact factor: 1.220, year: 2016

  13. IAEA research coordination meeting on X- and gamma-ray standards for detector efficiency calibration, Braunschweig, FRG, 31 May - 2 June 1989. Summary report

    International Nuclear Information System (INIS)

    Christmas, P.; Nichols, A.L.; Lemmel, H.D.

    1989-07-01

    The final official meeting of the IAEA Coordinated Research Programme on the Measurement and Evaluation of X- and Gamma-ray Standards for Detector Efficiency Calibration was held in Braunschweig from 31 May to 2 June 1989. Work undertaken by the participants was reviewed in detail, and actions were agreed to resolve specific issues and problems. Initial steps were also made to establish a format and procedure for the preparation by mid-1990 of an IAEA Technical Reports Series booklet; the measurements and recommended data will be listed, and an IAEA data file established for issue to all interested organisations. (author). 3 tabs

  14. Production Efficiency of Cocoon Shell of Silkworm, Bombyx mori L. (Bombycidae: Lepidoptera, as an Index for Evaluating the Nutritive Value of Mulberry, Morus sp. (Moraceae, Varieties

    Directory of Open Access Journals (Sweden)

    Jalaja Suresh Kumar

    2011-01-01

    Full Text Available The nutritional efficiency of mulberry leaves consumed by silkworms, Bombyx mori L., is usually evaluated in terms of the proportion of cocoon shell weight to the amount of food ingested. The production efficiency of cocoon shell is generally used to identify the superiority of a mulberry variety for silkworm rearing. In this study the production efficiency of cocoon shell was used as an index for evaluating the nutritive value of different mulberry varieties of India. Among the varieties, V-1, having highest production efficiency of cocoon shell with less amount of food ingested and highest digestibility, is regarded as the best suitable variety with nutritive values ideal for silkworm rearing.

  15. Improving Crystalline Silicon Solar Cell Efficiency Using Graded-Refractive-Index SiON/ZnO Nanostructures

    Directory of Open Access Journals (Sweden)

    Yung-Chun Tu

    2015-01-01

    Full Text Available The fabrication of silicon oxynitride (SiON/ZnO nanotube (NT arrays and their application in improving the energy conversion efficiency (η of crystalline Si-based solar cells (SCs are reported. The SiON/ZnO NT arrays have a graded-refractive-index that varies from 3.5 (Si to 1.9~2.0 (Si3N4 and ZnO to 1.72~1.75 (SiON to 1 (air. Experimental results show that the use of 0.4 μm long ZnO NT arrays coated with a 150 nm thick SiON film increases Δη/η by 39.2% under AM 1.5 G (100 mW/cm2 illumination as compared to that of regular SCs with a Si3N4/micropyramid surface. This enhancement can be attributed to SiON/ZnO NT arrays effectively releasing surface reflection and minimizing Fresnel loss.

  16. Efficient retrieval of vegetation leaf area index and canopy clumping factor from satellite data to support pollutant deposition assessments

    International Nuclear Information System (INIS)

    Nikolov, Ned; Zeller, Karl

    2006-01-01

    Canopy leaf area index (LAI) is an important structural parameter of the vegetation controlling pollutant uptake by terrestrial ecosystems. This paper presents a computationally efficient algorithm for retrieval of vegetation LAI and canopy clumping factor from satellite data using observed Simple Ratios (SR) of near-infrared to red reflectance. The method employs numerical inversion of a physics-based analytical canopy radiative transfer model that simulates the bi-directional reflectance distribution function (BRDF). The algorithm is independent of ecosystem type. The method is applied to 1-km resolution AVHRR satellite images to retrieve a geo-referenced data set of monthly LAI values for the conterminous USA. Satellite-based LAI estimates are compared against independent ground LAI measurements over a range of ecosystem types. Verification results suggest that the new algorithm represents a viable approach to LAI retrieval at continental scale, and can facilitate spatially explicit studies of regional pollutant deposition and trace gas exchange. - The paper presents a physics-based algorithm for retrieval of vegetation LAI and canopy-clumping factor from satellite data to assist research of pollutant deposition and trace-gas exchange. The method is employed to derive a monthly LAI dataset for the conterminous USA and verified at a continental scale

  17. Efficient retrieval of vegetation leaf area index and canopy clumping factor from satellite data to support pollutant deposition assessments

    Energy Technology Data Exchange (ETDEWEB)

    Nikolov, Ned [Natural Resource Research Center, 2150 Centre Avenue, Building A, Room 368, Fort Collins, CO 80526 (United States)]. E-mail: nnikolov@fs.fed.us; Zeller, Karl [USDA FS Rocky Mountain Research Station, 240 W. Prospect Road, Fort Collins, CO 80526 (United States)]. E-mail: kzeller@fs.fed.us

    2006-06-15

    Canopy leaf area index (LAI) is an important structural parameter of the vegetation controlling pollutant uptake by terrestrial ecosystems. This paper presents a computationally efficient algorithm for retrieval of vegetation LAI and canopy clumping factor from satellite data using observed Simple Ratios (SR) of near-infrared to red reflectance. The method employs numerical inversion of a physics-based analytical canopy radiative transfer model that simulates the bi-directional reflectance distribution function (BRDF). The algorithm is independent of ecosystem type. The method is applied to 1-km resolution AVHRR satellite images to retrieve a geo-referenced data set of monthly LAI values for the conterminous USA. Satellite-based LAI estimates are compared against independent ground LAI measurements over a range of ecosystem types. Verification results suggest that the new algorithm represents a viable approach to LAI retrieval at continental scale, and can facilitate spatially explicit studies of regional pollutant deposition and trace gas exchange. - The paper presents a physics-based algorithm for retrieval of vegetation LAI and canopy-clumping factor from satellite data to assist research of pollutant deposition and trace-gas exchange. The method is employed to derive a monthly LAI dataset for the conterminous USA and verified at a continental scale.

  18. Studies on mutagenic effectiveness and efficiency of gamma rays and its effect on quantitative traits in finger millet (Eleusine coracana L. Gaertn

    Directory of Open Access Journals (Sweden)

    A.R. Ambavane

    2015-01-01

    Full Text Available Dry seeds (12% moisture of two finger millet cultivar viz., Dapoli-1 and Dapoli Safed were irradiated with four doses of gamma-rays viz., 400 Gy, 500 Gy, 600 Gy and 700 Gy at BARC, Mumbai. In laboratory test, root and shoot lengths of seedlings were decreased with increase in dose of gamma rays. Similarly, germination percentage and survival rate of seedlings were decreased with increase in dose of gamma irradiation during field study. In M1 generation, three types of chlorophyll mutations viz., albino, xantha and viridis were observed. Albino and xantha were observed in all treatments, whereas, viridis observed only in lower doses viz., 400 Gy and 500 Gy. Based on the chlorophyll mutation frequency on M1 plants, mutagenic effectiveness and efficiency were computed. In Dapoli-1 variety, two early maturing mutants and three high yielding mutants were isolated from 500 Gy dose and 600 Gy dose, respectively. In M2 generation, the mutagenic treatments were effective in inducing various types of chlorophyll and morphological macro mutants, few of those show significant change in flowering, maturity and plant height character and few of them have good breeding value.

  19. Empirical Study on Total Factor Productive Energy Efficiency in Beijing-Tianjin-Hebei Region-Analysis based on Malmquist Index and Window Model

    Science.gov (United States)

    Xu, Qiang; Ding, Shuai; An, Jingwen

    2017-12-01

    This paper studies the energy efficiency of Beijing-Tianjin-Hebei region and to finds out the trend of energy efficiency in order to improve the economic development quality of Beijing-Tianjin-Hebei region. Based on Malmquist index and window analysis model, this paper estimates the total factor energy efficiency in Beijing-Tianjin-Hebei region empirically by using panel data in this region from 1991 to 2014, and provides the corresponding political recommendations. The empirical result shows that, the total factor energy efficiency in Beijing-Tianjin-Hebei region increased from 1991 to 2014, mainly relies on advances in energy technology or innovation, and obvious regional differences in energy efficiency to exist. Throughout the window period of 24 years, the regional differences of energy efficiency in Beijing-Tianjin-Hebei region shrank. There has been significant convergent trend in energy efficiency after 2000, mainly depends on the diffusion and spillover of energy technologies.

  20. Efficiency of lycopene extracted from tomato pomace as antioxidant against gamma irradiation hazards in male albino rats

    International Nuclear Information System (INIS)

    Abdallah, I.Z.A.; Kattab, H.A.H.; Sheashea, E.A.R.

    2003-01-01

    Nowadays, increasing attention has been given to the roles of free radicals generated through oxidative stres. The present study aims to evaluate the antioxidative role lycopene extracted from tomato processing wastes or pomace against hazards induced by gamma irradiation. Male rats were adminstered lycopene by a daily intragastric gavage(0.24mg/rat/day) or supplemented in a standard casein diet (6.5 Gy) of whole body gamma radiation. Lipid peroxides (MDA) reduced ghutathione (GSH) and superoxide dismutase activity (SOD) were determined in liver homogenate, as well as serum levels of alanine aminotransferase (ALT). asparate aminotransferase (AST), toral protein, albumin, globulin and A/G ratio were investigated 2 and 13 days post irradiation and/or lycopene administration. The results revealed that exposure to ionizing radiation resulted in significant elevation in MDA, ALT,AST, albumin levels and A/G ratio. Meanwhile, radiation exposure caused significant reduction in weight gain, SOD activity, GSH, total protein and globulin levels

  1. Efficiency evaluation of China's investment in Africa under the background of constructing "Silk Road Economic Belt": Application of DEA model and Malmquist index method

    OpenAIRE

    Ze, Tian; Yumei, Fan; Chao, Liu

    2018-01-01

    In recent years, with implementation and propulsion of the strategic planning "One Belt and One Road" of China, quality and efficiency of China's foreign direct investment have increasingly become a focused issue. This paper utilizes the DEA model and Malmquist index method to select the data of China's investment in 20 countries of Africa and conducts the empirical research on dynamic evaluation of efficiency of China's direct investment in Africa. The result shows that the general efficienc...

  2. Researches with the 'Fertexpert' model concerning the relationships between the efficiency indexes of the fertilizers usage in optimal economic rates and the agrochemical indexes of the soil and expected yields

    International Nuclear Information System (INIS)

    Budoi, G.; Berca, M.; Borlan, Z.; Gavriluta, I.; Soare, M.; Danuso, F.; Bireescu, L.

    1999-01-01

    The 'Fertexpert' model allows undertaking researches concerning the variation of efficiency indexes for fertilizers usage in the case of many crops depending on the content of available soil nutrients (the values of soil agrochemical indexes - IA) and on the expected yield, R s , when fertilization are applied in optimal economic rates, DOE. The physical efficiency indexes calculated and researched are the following: the total physical yield increase, SFR (kg/ha), the specific average yield increase, SSp (kg/kg N, P 2 O 5 or K 2 O), the specific consumption of active substance (a.s.) from fertilizer, CSp (kg a.s./1 kg average yield increase). The economic efficiency indexes computed are: the total profit, in monetary units/ha, the specific profit, in monetary units/l monetary unit spent with fertilization, PSp, and in monetary units/kg a.s., PSpsa. The model also allows the study of DOE variation depending on R s and IA. Starting from the made calculations, there can be drown up specific graphics that can then be used in practice and for research purposes to. Refs. 6 (author)

  3. Uranium, radium and thorium in soils with high-resolution gamma spectroscopy, MCNP-generated efficiencies, and VRF non-linear full-spectrum nuclide shape fitting

    Directory of Open Access Journals (Sweden)

    Metzger Robert

    2017-01-01

    Full Text Available A new method for analysis of uranium and radium in soils by gamma spectroscopy has been developed using VRF (“Visual RobFit” which, unlike traditional peak-search techniques, fits full-spectrum nuclide shapes with non-linear least-squares minimization of the chi-squared statistic. Gamma efficiency curves were developed for a 500 mL Marinelli beaker geometry as a function of soil density using MCNP. Collected spectra were then analyzed using the MCNP-generated efficiency curves and VRF to deconvolute the 90 keV peak complex of uranium and obtain 238U and 235U activities. 226Ra activity was determined either from the radon daughters if the equilibrium status is known, or directly from the deconvoluted 186 keV line. 228Ra values were determined from the 228Ac daughter activity. The method was validated by analysis of radium, thorium and uranium soil standards and by inter-comparison with other methods for radium in soils. The method allows for a rapid determination of whether a sample has been impacted by a man-made activity by comparison of the uranium and radium concentrations to those that would be expected from a natural equilibrium state.

  4. Uranium, radium and thorium in soils with high-resolution gamma spectroscopy, MCNP-generated efficiencies, and VRF non-linear full-spectrum nuclide shape fitting

    Science.gov (United States)

    Metzger, Robert; Riper, Kenneth Van; Lasche, George

    2017-09-01

    A new method for analysis of uranium and radium in soils by gamma spectroscopy has been developed using VRF ("Visual RobFit") which, unlike traditional peak-search techniques, fits full-spectrum nuclide shapes with non-linear least-squares minimization of the chi-squared statistic. Gamma efficiency curves were developed for a 500 mL Marinelli beaker geometry as a function of soil density using MCNP. Collected spectra were then analyzed using the MCNP-generated efficiency curves and VRF to deconvolute the 90 keV peak complex of uranium and obtain 238U and 235U activities. 226Ra activity was determined either from the radon daughters if the equilibrium status is known, or directly from the deconvoluted 186 keV line. 228Ra values were determined from the 228Ac daughter activity. The method was validated by analysis of radium, thorium and uranium soil standards and by inter-comparison with other methods for radium in soils. The method allows for a rapid determination of whether a sample has been impacted by a man-made activity by comparison of the uranium and radium concentrations to those that would be expected from a natural equilibrium state.

  5. Detection efficiency for radionuclides decaying by electron capture and gamma-Ray; Calculo de la eficiencia de deteccion de nucleidos que se desintegran por captura elec- tronica y emision gamma

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A; Fernandez, A

    1985-07-01

    In this paper, the electron capture partial counting efficiency vs the figure of merit for electron-capture and gamma-ray emitters has been computed. The radionuclides tabulated are 48{sup c}r, 54{sup M}n, 57{sup C}o 56{sup N}i, 72{sup S}e, 73{sup A}s, 85{sup S}r, 88{sup Z}r, 92{sup N}b, 103{sup P}d, 111{sup l}n, 119{sup S}b, 125{sup I}, 139{sup C}e and 152{sup D}y. It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 15 cm{sup 3}. (Author) 17 refs.

  6. Mortality of tyrophagus putrescentiae (Schrank) females exposed to a high ratio of gamma-irradiated males as an index of radiation impact on sexual vigor of males

    International Nuclear Information System (INIS)

    Ignatowicz, S.

    1990-01-01

    A 40 or 60 krad dose of gamma radiation reduce slightly sexual activity of the males but male activity is greatly reduced as the radiation dose increases from 60 to 120 krad. Females of the mold mite, Tyrophagus, putrescentiae (Schrank), molested by males present at a 3:1 or 5:1 ratio live shorter than females kept with one male. The SAG test can be applied to compare sexual activity of males treated with different dosage of gamma irradiation

  7. GammaWorkshops Proceedings

    International Nuclear Information System (INIS)

    Ramebaeck, H.; Straelberg, E.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.

    2012-01-01

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  8. Computation of full energy peak efficiency for nuclear power plant radioactive plume using remote scintillation gamma-ray spectrometry.

    Science.gov (United States)

    Grozdov, D S; Kolotov, V P; Lavrukhin, Yu E

    2016-04-01

    A method of full energy peak efficiency estimation in the space around scintillation detector, including the presence of a collimator, has been developed. It is based on a mathematical convolution of the experimental results with the following data extrapolation. The efficiency data showed the average uncertainty less than 10%. Software to calculate integral efficiency for nuclear power plant plume was elaborated. The paper also provides results of nuclear power plant plume height estimation by analysis of the spectral data. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. In vivo studies on the experimental tumour sarcoma 180 in order to determine the therapeutic efficiency of gamma and neutron irradiation combined with hyperthermia and misonidazole

    International Nuclear Information System (INIS)

    Weber, H.J.

    1982-01-01

    The influence of hyperthermia and/or Misonidazole on the therapeutic effect of gamma and neutron irradiation was investigated for the solid experimental tumour Sarcoma 180 in NMRI mice. Apart from the common biological parameters (tumour volume, growth retardation, tumour regression), also cellular effects and cell metabolism were studied in vivo by I-UdR lavelling without disturbing the tumour/host interaction. Sequential double labelling with 125 I-UdR and 131 I-UdR before treatment and measurement of rates of activity loss afterwards yielded information on cell metabolism and therapeutic efficiency. The influence of different therapies on the proliferation activity was assessed by injection of 125 I-UdR at different times after treatment, followed by measurements of the incorporation rate. The diagnostic value of the methods of measurement and the possibility of transferring the findings of animal experiments to clinical practice were investigated. (orig./MG) [de

  10. Efficient in situ synthetic routes of polyaniline/poly(vinyl alcohol)/TiO2 nanocomposites using gamma irradiation

    Science.gov (United States)

    Afify, T. A.; Ghazy, O. A.; Saleh, H. H.; Ali, Z. I.

    2018-02-01

    Gamma radiation was used to prepare nanocomposites based on polyaniline/titanium dioxide (PANI/TiO2) or polyaniline/poly (vinyl alcohol)/titanium dioxide (PANI/PVA/TiO2). It was found that PANI/TiO2 in the form of nanocomposite as shown by the UV/vis spectroscopy. This was through the appearance and shift of two absorption peaks at 340 and 598 nm. The SEM micrographs of the PANI/TiO2 nanocomposites showed a fibrous morphology before the treatment with HCl. The TiO2 nanoparticles are clearly seen to be precipitated on the PANI fibers and the morphology changed towards the sheets shape with highly distribution on PANI surface. The transmission electron microscopy (TEM) image confirms the fibrous shape of the PANI and spherical shape of TiO2 nanoparticles. The XRD study showed a several diffraction patterns of TiO2 nanoparticles confirming the PANI/TiO2 and PANI/PVA/TiO2 nanocomposites. The FT-IR analysis indicated that there is an interfacial interaction existed between the PANI and its inorganic counterpart of TiO2 nanoparticles. The dielectric constant of the PANI/PVA showed the lowest values and was increased by either doping with TiO2 or increasing irradiation dose.

  11. Impact of detector efficiency and energy resolution on gamma-ray background rejection in mobile spectroscopy and imaging systems

    Energy Technology Data Exchange (ETDEWEB)

    Aucott, Timothy J., E-mail: Timothy.Aucott@SRS.gov [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Bandstra, Mark S. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Negut, Victor; Curtis, Joseph C. [University of California, Berkeley, Department of Nuclear Engineering, Berkeley, CA (United States); Meyer, Ross E.; Chivers, Daniel H. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Vetter, Kai [University of California, Berkeley, Department of Nuclear Engineering, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States)

    2015-07-21

    The presence of gamma-ray background significantly reduces detection sensitivity when searching for radioactive sources in the field, and the systematic variability in the background will limit the size and energy resolution of systems that can be used effectively. An extensive survey of the background was performed using both sodium iodide and high-purity germanium. By using a bivariate negative binomial model for the measured counts, these measurements can be resampled to simulate the performance of a detector array of arbitrary size and resolution. The response of the system as it moved past a stationary source was modeled for spectroscopic and coded aperture imaging algorithms and used for source injection into the background. The performance of both techniques is shown for various sizes and resolutions, as well as the relative performance for sodium iodide and germanium. It was found that at smaller detector sizes or better energy resolution, spectroscopy has higher detection sensitivity than imaging, while imaging is better suited to larger or poorer resolution detectors.

  12. Cation Exchange Efficiency Of Modified Bentonite Using In-Situ GAMMA Radiation Polymerization Of Acrylic Acid Or Acrylamide

    International Nuclear Information System (INIS)

    ISMAIL, S.A.; FALAZI, B.

    2009-01-01

    Modified bentonites as cation exchangers were prepared by treating raw bentonite with 3N NaOH at 95 0 C followed by in-situ polymerization using gamma irradiation as well as hydrogen peroxide initiation of acrylic acid or acrylamide in the matrix.Water swelling and acid capacity were determined and cation exchange capacity for Cu 2+ , Ni 2+ and Co 2+ was evaluated. It has been found that catiexchange capacity of treated bentonite was increased as result of formed polyacrylic acid and polyacrylamide in the matrix. In case of acrylic acid, the maximum cation exchange capacities of 3.5, 3.1 and 2.5 mg equivalent/g were determined for Cu 2+ , Ni 2+ and Co 2+ , respectively, and for acrylamide, the corresponding capacities were 2.9, 2.8 and 2.6 mg equivalent/g, respectively. Water swelling was found to be associated with holding large amounts of water, for instance, 49 g of water was sorbed per one gram of the sodium salt form of polyacrylic acid in bentonite matrix, in other words the degree of swelling in water achieved 4500%.

  13. Antireflective sub-wavelength structures for improvement of the extraction efficiency and color rendering index of monolithic white light-emitting diode

    DEFF Research Database (Denmark)

    Ou, Yiyu; Corell, Dennis Dan; Dam-Hansen, Carsten

    2011-01-01

    We have theoretically investigated the influence of antireflective sub-wavelength structures on a monolithic white light-emitting diode (LED). The simulation is based on the rigorous coupled wave analysis (RCWA) algorithm, and both cylinder and moth-eye structures have been studied in the work. Our...... simulation results show that a moth-eye structure enhances the light extraction efficiency over the entire visible light range with an extraction efficiency enhancement of up to 26 %. Also for the first time to our best knowledge, the influence of sub-wavelength structures on both the color rendering index...

  14. Efficiency and Productivity of County-level Public Hospitals Based on the Data Envelopment Analysis Model and Malmquist Index in Anhui, China.

    Science.gov (United States)

    Li, Nian-Nian; Wang, Cun-Hui; Ni, Hong; Wang, Heng

    2017-12-05

    China began to implement the national medical and health system and public hospital reforms in 2009 and 2012, respectively. Anhui Province is one of the four pilot provinces, and the medical reform measures received wide attention nationwide. The effectiveness of the above reform needs to get attention. This study aimed to master the efficiency and productivity of county-level public hospitals based on the data envelopment analysis (DEA) model and Malmquist index in Anhui, China, and then provide improvement measures for the future hospital development. We chose 12 country-level hospitals based on geographical distribution and the economic development level in Anhui Province. Relevant data that were collected in the field and then sorted were provided by the administrative departments of the hospitals. DEA models were used to calculate the dynamic efficiency and Malmquist index factors for the 12 institutions. During 2010-2015, the overall average relative service efficiency of 12 county-level public hospitals was 0.926, and the number of hospitals achieved an effective DEA for each year from 2010 to 2015 was 4, 6, 7, 7, 6, and 8, respectively, as measured using DEA. During this same period, the average overall production efficiency was 0.983, and the total productivity factor had declined. The overall production efficiency of five hospitals was >1, and the rest are productivity has not been effectively improved. County-level public hospitals need to combine their own reality to find their own deficiencies.

  15. Establishment of the Relationship between the Photochemical Reflectance Index and Canopy Light Use Efficiency Using Multi-angle Hyperspectral Observations

    Science.gov (United States)

    Zhang, Qian; Chen, Jing; Zhang, Yongguang; Qiu, Feng; Fan, Weiliang; Ju, Weimin

    2017-04-01

    The gross primary production (GPP) of terrestrial ecosystems constitutes the largest global land carbon flux and exhibits significant spatial and temporal variations. Due to its wide spatial coverage, remote sensing technology is shown to be useful for improving the estimation of GPP in combination with light use efficiency (LUE) models. Accurate estimation of LUE is essential for calculating GPP using remote sensing data and LUE models at regional and global scales. A promising method used for estimating LUE is the photochemical reflectance index (PRI = (R531-R570)/(R531 + R570), where R531 and R570 are reflectance at wavelengths 531 and 570 nm) through remote sensing. However, it has been documented that there are certain issues with PRI at the canopy scale, which need to be considered systematically. For this purpose, an improved tower-based automatic canopy multi-angle hyperspectral observation system was established at the Qianyanzhou flux station in China since January of 2013. In each 15-minute observation cycle, PRI was observed at four view zenith angles fixed at solar zenith angle and (37°, 47°, 57°) or (42°, 52°, 62°) in the azimuth angle range from 45° to 325° (defined from geodetic north). To improve the ability of directional PRI observation to track canopy LUE, the canopy is treated as two-big leaves, i.e. sunlit and shaded leaves. On the basis of a geometrical optical model, the observed canopy reflectance for each view angle is separated to four components, i.e. sunlit and shaded leaves and sunlit and shaded backgrounds. To determine the fractions of these four components at each view angle, three models based on different theories are tested for simulating the fraction of sunlit leaves. Finally, a ratio of canopy reflectance to leaf reflectance is used to represent the fraction of sunlit leaves, and the fraction of shaded leaves is calculated with the four-scale geometrical optical model. Thus, sunlit and shaded PRI are estimated using

  16. Photoperiod and temperature constraints on the relationship between the photochemical reflectance index and the light use efficiency of photosynthesis in Pinus strobus

    OpenAIRE

    Fr?chette, Emmanuelle; Chang, Christine Yao-Yun; Ensminger, Ingo

    2016-01-01

    The photochemical reflectance index (PRI) is a proxy for the activity of the photoprotective xanthophyll cycle and photosynthetic light use efficiency (LUE) in plants. Evergreen conifers downregulate photosynthesis in autumn in response to low temperature and shorter photoperiod, and the dynamic xanthophyll cycle-mediated non-photochemical quenching (NPQ) is replaced by sustained NPQ. We hypothesized that this shift in xanthophyll cycle-dependent energy partitioning during the autumn is the c...

  17. GammaWorkshops Proceedings

    DEFF Research Database (Denmark)

    Strålberg, Elisabeth; Klemola, Seppo; Nielsen, Sven Poul

    to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical...

  18. EFFICIENCY OF BORAGE SEEDS OIL AGAINST GAMMA IRRADIATION-INDUCED HEPATOTOXICITY IN MALE RATS: POSSIBLE ANTIOXIDANT ACTIVITY.

    Science.gov (United States)

    Khattab, Hala A H; Abdallah, Inas Z A; Yousef, Fatimah M; Huwait, Etimad A

    2017-01-01

    Borage ( Borago officinal L.) is an annual herbaceous plant of great interest because its oil contains a high percentage of γ-linolenic acid (GLA). The present work was carried out to detect fatty acids composition of the oil extracted from borage seeds (BO) and its potential effectiveness against γ-irradiation- induced hepatotoxicity in male rats. GC-MS analysis of fatty acids methyl esters of BO was performed to identify fatty acids composition. Sixty rats were divided into five groups (12 rats each): Control, irradiated; rats were exposed to (6.5 Gy) of whole body γ-radiation, BO (50 mg/kg b.wt), irradiated BO post-treated and irradiated BO prepost-treated. Six rats from each group were sacrificed at two time intervals 7 and 15 days post-irradiation. Serum aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma glutamyl transferase (GGT) levels, lipids profile, as well as serum and hepatic reduced glutathione (GSH) and lipid peroxide (malondialdehyde) (MDA) levels were assessed. Histopathological examination of liver sections were also carried out. The results showed that the high contents of BO extracted by cold pressing, were linoleic acid (34.23%) and GLA (24.79%). Also, oral administration of BO significantly improved serum levels of liver enzymes, lipids profile, as well as serum and hepatic GSH and MDA levels (p<0.001) as compared with irradiated rats after 15 days post irradiation. Moreover, it exerted marked amelioration against irradiation-induced histopathological changes in liver tissues. The improvement was more pronounced in irradiated BO prepost-treated group than irradiated BO post-treated. BO has a beneficial role in reducing hepatotoxicity and oxidative stress induced by radiation exposure. Therefore, BO may be used as a beneficial supplement for patients during radiotherapy treatment.

  19. Improvement of the Bacterial Pure Culture 3A by Gamma Irradiation for Increasing Efficiency in Degrading Pesticides

    International Nuclear Information System (INIS)

    Tongpim, Saowanit; Piadaeng, Nattaya

    2006-09-01

    This research work had an objective to improve bacterial activity in degrading a herbicide: 2,4-dichlorophenoxyacetic acid (2,4-D). The bacterial isolate 3 A , kept in the culture collection of Khon Kaen University that could degrade 2,4-D, was employed in this experiment. Cell suspension of isolate 3 A was exposed to gamma irradiation at various doses (1-5 kGy). The isolated survivors were screened on the basis of forming larger colonies than the parent strain 3 A when grown on mineral salts agar containing 2,4-D (MS + 2,4-D) as the sole carbon source. We obtained 70 effective isolates which 6 isolates called 3 A I2-21, 3 A I2-23, 3 A I1-51, 3 A I2-71, 3 A I1-52 and 3 A I2-73 were chosen for further studies. These 6 irradiated isolates together with the parent strain were characterized using morphological, physiological and biochemical tests. They were all identified as Pseudomonas cepacia. All isolates had optimal growth pH of 7 and grew best at 30 o C. Biodegradation experiments performed in mineral salts medium containing 200 ppm of 2,4-D showed that after 20 days of incubation 36.9%, 65.3%, 57.2%, 54.8%, 53.4%, 47.3% and 45.8% of 2,4- D was degraded by isolates 3 A , 3 A I2-21, 3 A I2-23, 3 A I1-51, 3 A I2-71, 3 A I1-52 and 3 A I2-73, respectively. Comparing the irradiated strains with parent strain 3 A revealed that the isolate 3 A I2-21 was the most effective one as it could degrade 2,4-D about 28.4% greater than the parent strain 3 A .

  20. The influence of prolonged gamma irradiation on morpho functional indexes of blood capillaries of ovary in 20-day foetuses white rat

    International Nuclear Information System (INIS)

    Ablekovskaya, O.N.; Amvros'ev, A.P.

    1999-01-01

    It was studied the character and direction of structural transformations of blood capillaries of micro circulatory channel of 20-days white rat foetus in normal conditions and after prolonged action of gamma-radiation in the whole period of embryogenesis (absorbed dose 0,43 Gy).The peculiarities of reactions of hemo capillaries and their cell structure to gamma-rays action in embryogenesis were revealed. It was shown the decrease of diameters of capillaries, diminution of section area of cytoplasm of endotheliocytes, extension of the size of nuclei of these cells. Polyploid endotheliocytes were found in the experimental conditions. Prenatal irradiation in doses leaded to reduction of the number of microvessels and mitochondria in cytoplasm of cells of blood capillaries in ovary of rat foetus. These results revealed that low dose prolonged action of gamma-radiation during the period of embryogenesis changed the morphological parameters of important synthetic, transport and energy processes in capillary cells of ovary in fetal period of ontogenesis

  1. AN EFFICIENT ANALYSIS FOR ABSORPTION AND GAIN COEFFICIENTS IN 'SINGLE STEP-INDEX WAVEGUIDE'S BY USING THE ALPHA METHOD

    Directory of Open Access Journals (Sweden)

    Mustafa TEMİZ

    2008-02-01

    Full Text Available In this study, some design parameters such as normalized frequency and especially normalized propagation constant have been obtained, depending on some parameters which are functions of energy eigenvalues of the carriers such as electrons and holes confined in a single step-index waveguide laser (SSIWGL or single stepindex waveguide (SSIWG. Some optical expressions about the optical power and probability quantities for the active region and cladding layers of the SSIWG or SSIWGL have been investigated. Investigations have been undertaken in terms of these parameters and also individually the optical even and odd electric field waves with the lowest-modes were theoretically computed. Especially absorption coefficients and loss coefficients addition to some important quantities of the single step-index waveguide lasers for the even and odd electric field waves are evaluated.

  2. Highly efficient channel waveguide lasers at 1 µm and 2 µm in refractive-index-engineered potassium double tungstates

    NARCIS (Netherlands)

    van Dalfsen, Koop; Geskus, D.; García Blanco, Sonia Maria; Pollnau, Markus

    Epitaxial growth of rare-earth-ion-activated KY(1-x-y)Gd(x)Lu(y)(WO4)2 co-doped thin layers onto KY(WO4)2 substrates has enabled lattice-matched waveguides with high refractive-index contract and large variation of the active rare-earth-ion concentration. In Yb3+-activated micro-structured channel

  3. Formation of the Integral Ecological Quality Index of the Technological Processes in Machine Building Based on Their Energy Efficiency

    Science.gov (United States)

    Egorov, Sergey B.; Kapitanov, Alexey V.; Mitrofanov, Vladimir G.; Shvartsburg, Leonid E.; Ivanova, Natalia A.; Ryabov, Sergey A.

    2016-01-01

    The aim of article is to provide development of a unified assessment methodology in relation to various technological processes and the actual conditions of their implementation. To carry the energy efficiency analysis of the technological processes through comparison of the established power and the power consumed by the actual technological…

  4. Improving efficiency of the entomopathogenic fungi by gamma irradiation versus the Mediterranean fruit fly ceratitis capitata wiedemann (Diptera: Tephritidae)

    International Nuclear Information System (INIS)

    Fadel, A.M.; Haggag, W.M.

    2002-01-01

    The efficiency of wild and irradiated biocontrol fungi, Beauvaria Bassiana (Blsamo) and Trichoderma Harzianum (Rafai) on the Mediterranean Fruit fly Ceratitis Capitata (Wiedemann) was investigated. Applying wild B. bassiana and T. harzianum using spores suspension at different concentrations (10 8 , 10 6 and 10 4 colony-forming units), on the pupation medium (sand) or in drinking water, resulted in a significant reduction in adult emergence of pupae (1-2 day-old) and survival of produced adults. Meanwhile, the introduction of some isolates irradiated at 150 and 300 Gy significantly reduced adult emergence from pupae (1-2 day-old) and survival was greatly increased by isolates irradiated at 150 Gy of B. bassiana and at Gy in case of T. harzianum. Applying irradiated isolates as culture filtrate with the concentrations of 10, 50 and 100% to the pupation medium or in drinking water, resulted in a reduction of adult emergence and survival. The results revealed that bioagents B. bassiana and T. harzianum can be applied in the field to suppress the population of the mediterranean fruit fly ceratitis capitata and considered as entomopathogenic for controlling this pest

  5. The effects of sampling on the efficiency and accuracy of k-mer indexes: Theoretical and empirical comparisons using the human genome.

    Science.gov (United States)

    Almutairy, Meznah; Torng, Eric

    2017-01-01

    One of the most common ways to search a sequence database for sequences that are similar to a query sequence is to use a k-mer index such as BLAST. A big problem with k-mer indexes is the space required to store the lists of all occurrences of all k-mers in the database. One method for reducing the space needed, and also query time, is sampling where only some k-mer occurrences are stored. Most previous work uses hard sampling, in which enough k-mer occurrences are retained so that all similar sequences are guaranteed to be found. In contrast, we study soft sampling, which further reduces the number of stored k-mer occurrences at a cost of decreasing query accuracy. We focus on finding highly similar local alignments (HSLA) over nucleotide sequences, an operation that is fundamental to biological applications such as cDNA sequence mapping. For our comparison, we use the NCBI BLAST tool with the human genome and human ESTs. When identifying HSLAs, we find that soft sampling significantly reduces both index size and query time with relatively small losses in query accuracy. For the human genome and HSLAs of length at least 100 bp, soft sampling reduces index size 4-10 times more than hard sampling and processes queries 2.3-6.8 times faster, while still achieving retention rates of at least 96.6%. When we apply soft sampling to the problem of mapping ESTs against the genome, we map more than 98% of ESTs perfectly while reducing the index size by a factor of 4 and query time by 23.3%. These results demonstrate that soft sampling is a simple but effective strategy for performing efficient searches for HSLAs. We also provide a new model for sampling with BLAST that predicts empirical retention rates with reasonable accuracy by modeling two key problem factors.

  6. Application of Gamma Radiation to Enhance Heavy Metals Removal Efficiency to Bacteria Isolated from Ronpiboon District, Nakhon Sri Thamarat Province, Thailand

    International Nuclear Information System (INIS)

    Intrasungkha, Nugul; Wisapan, Walakon; Piadang, Nattayana

    2006-09-01

    The objective of this study was to isolate soil bacteria capable to te move 4 heavy metals, namely, arsenic (As(III)), lead Pb(II) and cadmium f ron old tin mine in Ronpiboon district, Nakhon Sri Thamarat. It was found that there were bacteria which capable to resist arsenic, lead and copper 11, 15, 8 and 2 ileitis, respectively[evacuate;y. The arsenic removal efficiency of these bacteria was evaluated at the low concentration of 1 u g/l. with the results of 7-61%. The lead and copper removal efficiencies at 10 mg/l were found at the range pf 9-98% and 8-40%, respectively. Six isolates of bacteria (KRD, KRH, KRM, KCD13 and KCD14) were selected to be irradiated by gamma radiation at the levels of 2-10 kGy. The heavy metals resistance was found increase in the range of of 125-16% for arsenic, 0-50% for copper, 0-18% for lead and 0-17% for cadmium, respectively. Also ut was found that the low temperature at 4 and -40 degree Celsius can prolong the bacterial survival up to 6 months. Later the arsenic removal experiment in liquid medium was conducted and it was found that the mutants can perform slightly better than wild type only >17%. It was due to the initial concentration of arsenic was too high (10 mg/l). The preliminary study of arsenic removal in soil was also conducted using pack-bed reactor. We found the proper ratio of pack material (soil and gravel) was 1:1 to promote the liquid and air circulation. The suitable medium was found to be acidified mo lass solution which were found promote the growth of tested bacterial isolates.

  7. Estimation of track registration efficiency in solution medium and study of gamma irradiation effects on the bulk-etch rate and the activation energy for bulk etching of CR-39 (DOP) Solid State Nuclear Track Detector

    International Nuclear Information System (INIS)

    Kalsi, P.C.

    2010-01-01

    The fission track registration efficiency of diethylene glycol bis allyl carbonate (dioctyl phthalate doped) (CR-39 (DOP)) solid state nuclear track detector (SSNTD) in solution medium (K wet ) has been experimentally determined and is found to be (9.7 ± 0.5).10 -4 cm. This is in good agreement with the values of other SSNTDs. The gamma irradiation effects in the dose range of 50.0-220.0 kGy on the bulk etch rate, V b and the activation energy for bulk etching, E of this solid state nuclear track detector (SSNTD) have also been studied. It is observed that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation

  8. [Construction of a recombinant Escherichia coli BL21/ pET-28a-lpgad and the optimization of transformation conditions for the efficient production of gamma-aminobutyric acid].

    Science.gov (United States)

    Tian, Lingzhi; Xu, Meijuan; Rao, Zhiming

    2012-01-01

    In order to enhance gamma-aminobutyric acid production from L-glutamate efficiently, we amplified the key enzyme glutamate decarboxylase (GAD) encoding gene lpgad from the strain Lactobacillus plantarum GB 01-21 which was obtained by way of multi-mutagenesis and overexpressed it in E. coli BL21. Then we purified GAD by Ni-NTA affinity chromatography and characterized the enzyme to optimize the conditions of the whole-cell transformation. The results showed that the recombinant E. coli BL21 (pET-28a-lpgad) produced 8.53 U/mg GAD, which was increased by 3.24 fold compared with the GAD activity in L. plantarum. The optimum pH and temperature of the enzyme were pH 4.8 and 37 degrees C, respectively. At the same time, we found that Ca2+ and Mg2+ could increase the activity significantly. Based on this, we investigated gamma-aminobutyric acid transformation in 5 L fermentor under the optimum transformation conditions. Accordingly, the yield of gamma-aminobutyric acid was 204.5 g/L at 24 h when the 600 g L-glutamate was added and the mole conversion rate had reached 97.92%. The production of gamma-aminobutyric acid was improved by 42.5% compared with that under the unoptimized transformation conditions. This paved a way for the gamma-aminobutyric acid construction of the industrial applications.

  9. Application of radiometric core data in developing correlation index for insitu gamma log and disequilibrium status across exploratory boreholes: a case study in Wahkut Block of West Khasi Hills District, Meghalaya, India

    International Nuclear Information System (INIS)

    Kukreti, B.M.; Kumar, Pramod

    2011-01-01

    With the objective to affirm apparent Uranium ore zone grade/thickness with good confidence for non-coring and coring boreholes with poor core recovery, a systematic study in the mineralised coring boreholes between insitu measured gamma ray log and laboratory measured core assay has been carried out, in the sedimentary environment of Wahkut block, West Khasi Hills district of Meghalaya. This also helps in quantifying correlation index and U disequilibrium status across the drilled boreholes and to convert apparent eU 3 O 8 grade to ore reserve (U 3 O 8 ). Study area consist of 2 sq km having 33 coring and 39 non coring boreholes with cumulative drilled depth of about 11,000 mts. On this available database, grade thickness continuity of uranium ore zone, in coring boreholes was evaluated with the criteria of minimal ore zone thickness of 1.0 mts at 100 ppm eU 3 O 8 cut-off grade. The same criteria were also extended to the core assay of drilled core. A population of 19 such simultaneous qualifying zone (borehole log and core assay) meeting the set criteria from 17 coring boreholes (average core recovery > 90%) was drawn. Study results gave grade thickness continuity index of 0.93 between radiometric core assay and borehole log with moderately strong relationship. Disequilibrium status of apparent eU 3 O 8 grade in the borehole was examined using chemically checked U 3 O 8 (β/γ) (Having high degree uranium data confidence 91%) and Ra (e) plot, after getting complete core samples radiometric and spectral gamma analysed for 14 such boreholes. Equilibrium status on this population indicates, disequilibrium in favour of parent (0.90-1.78 range) having log normal distribution and skewed to the higher side of mean 1.37 disequilibrium factor. (author)

  10. Efficiency of S&P CNX Nifty Index Option of the National Stock Exchange (NSE, India, using Box Spread Arbitrage Strategy

    Directory of Open Access Journals (Sweden)

    G. P. Girish

    2014-09-01

    Full Text Available Box spread is a trading strategy in which one simultaneously buys and sells options having the same underlying asset and time to expiration, but different exercise prices. This study examined the efficiency of European style S&P CNX Nifty Index options of National Stock Exchange, (NSE India by making use of high-frequency data on put and call options written on Nifty (Time-stamped transactions data for the time period between 1st January 2002 and 31st December 2005 using box-spread arbitrage strategy. The advantages of box-spreads include reduced joint hypothesis problem since there is no consideration of pricing model or market equilibrium, no consideration of inter-market non-synchronicity since trading box spreads involve only one market, computational simplicity with less chances of mis-specification error, estimation error and the fact that buying and selling box spreads more or less replicates risk-free lending and borrowing. One thousand three hundreds and fifty eight exercisable box-spreads were found for the time period considered of which 78 Box spreads were found to be profitable after incorporating transaction costs (32 profitable box spreads were identified for the year 2002, 19 in 2003, 14 in 2004 and 13 in 2005 The results of our study suggest that internal option market efficiency has improved over the years for S&P CNX Nifty Index options of NSE India.

  11. Phenotypically divergent classification of preweaned heifer calves for feed efficiency indexes and their correlations with heat production and thermography.

    Science.gov (United States)

    Leão, J M; Coelho, S G; Machado, F S; Azevedo, R A; Lima, J A M; Carneiro, J C; Lage, C F A; Ferreira, A L; Pereira, L G R; Tomich, T R; Campos, M M

    2018-03-07

    The aims of this study were (1) to assess if there is phenotypical divergence for feed efficiency (FE) during the preweaning phase; (2) if FE is correlated with heat production (HP) measured by the face mask method or (3) by surface skin temperature via thermography, and (4) whether these methods are applicable to preweaned calves. Holstein × Gyr heifer calves (n = 36, birth body weight = 32.4 ± 6.6 kg) were enrolled and on trial between 4 and 12 wk of age and were classified into 2 residual feed intake (RFI) and residual body weight gain (RG) groups: high efficiency (HE; RFI, n = 10; and RG, n = 9) and low efficiency (LE; RFI, n = 10; and RG, n = 8). Calves were fed milk (6 L/d) and solid feed (95% starter and 5% chopped Tifton 85 hay, as fed). Growth was monitored weekly and feed intake (milk and solid feed) daily, during the whole period. Gas exchanges (O 2 consumption and production of CO 2 and CH 4 ) were obtained using a face mask at 45 ± 5 d of age and HP was estimated. Maximum temperatures were measured at 7 sites with an infrared camera at 62 ± 7 d of age. There was divergence in RFI and RG. Respectively, HE and LE calves had RFI of -0.14 and 0.13 kg/d, and RG of 0.05 and -0.07 kg/d. Dry matter intake was 15% lower in HE-RFI compared with LE-RFI, but no differences were observed in average daily weight gain. Within the RG test, no differences were observed in dry matter intake or average daily gain. The HE-RFI calves consumed less O 2 (L/d) and produced less CO 2 (L/d). Heart rate and HP were lower for HE-RFI calves compared with LE-RFI. Residual feed intake was correlated with HP (r = 0.48), O 2 consumption (r = 0.48), CO 2 production (r = 0.48), and heart rate (r = 0.40). No differences were observed in HP and gas exchanges between RG groups. Methane production was null in both groups. Eye temperature measured by thermography was 0.5°C greater in HE-RG than LE-RG calves. Differences in skin temperature between HE and LE calves were not observed at

  12. The CD3 gamma leucine-based receptor-sorting motif is required for efficient ligand-mediated TCR down-regulation

    DEFF Research Database (Denmark)

    von Essen, Marina; Menné, Charlotte; Nielsen, Bodil L

    2002-01-01

    . The other pathway is dependent on protein kinase C (PKC)-mediated activation of the CD3 gamma di-leucine-based receptor-sorting motif. Previous studies have failed to demonstrate a connection between ligand- and PKC-induced TCR down-regulation. Thus, although an apparent paradox, the dogma has been...... that ligand- and PKC-induced TCR down-regulations are not interrelated. By analyses of a newly developed CD3 gamma-negative T cell variant, freshly isolated and PHA-activated PBMC, and a mouse T cell line, we challenged this dogma and demonstrate in this work that PKC activation and the CD3 gamma di...

  13. THE DRAINAGE EFFICIENCY INDEX (DEI) AS AN MORPHOLOGIAL INDICATOR OF LANDSLIDE SPATIAL OCCURRENCE IN MOUNTAINOUS CATCHMENTS. A case of study applied in the mountainous region of Brazilian Southeastern.

    Science.gov (United States)

    Henrique Muniz Lima, Pedro; Luiza Coelho Netto, Ana; do Couto Fernandes, Manoel

    2016-04-01

    Morphometric parameters, acquired notoriety mainly after the Drainage Density proposition (Horton 1932, 1945) and after they were applied by geomorphologists on the perspective to understand landscape functionalities, quantifying their characteristics through parameters and indexes. After the drainage density, many other parameters which describe the basin characteristics, behavior and dynamics have been proposed. Among them, for example, the DEI was proposed by Coelho Netto and contributors during the 80's, while they were seek to understand the hydrological and erosive dynamics on Bananal river basin (Brazilian Southeastern). Through this investigations the DEI was created, revealing the importance of parameters as hollow and drainage density, conjugated to the topographic gradient (Meis et al. 1982) who prosecute controls on the water flow efficiency along the hollows in order to activate the regressive erosion of the main channel. Later on this index was applied on the basin scale in several works developed in mountainous regions, showing a remarkable correlation with the occurrence of landslides such as showed by Coelho Netto et al. (2007); that posteriorly use this index as one of the components of the landslide susceptibility map for the Tijuca Massif, located in Rio de Janeiro Municipality. This work aims to establish patterns of the DEI index values (applied to mountainous low order basins) and the relationship on the occurrence of Debriflows or shallow translational slides. For this, the DEI index was applied on 4 different study areas located on the Southeastern mountainous region of Brazil to address deeply the connection between the index and the occurrence of landslides of different types applied for first and second order basins. The major study area is the Córrego Dantas Basin, situated in Nova Friburgo municipality (RJ), which is a 53 km² basin was affected by 327 landslides caused by a heavy rainfall on January 2011; Coelho Netto et al. (in

  14. An efficient synthesis of S-[gamma]-[(4-trifluoromethyl)phenoxy] benzenepropanamine-[1-[sup 14]C]maleate, an important metabolite of fluoxetine hydrochloride. [Antidepressant, serotonin uptake inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Wheeler, W.J. (Lilly (Eli) and Co., Indianapolis, IN (United States). Lilly Research Labs.)

    1992-02-01

    S-[gamma]-[(4-Trifluoromethyl)phenoxy]benzenepropanamine-[1-[sup 14]C] maleate has been prepared in six steps from R-(-)1-phenyl-1,2-ethanediol. The isotope was incorporated by the reaction of NaCN-[[sup 14]C] with the tert. butyldimethylsilyl ether of R-(-)1-phenyl-1,2-ethane-diol 2-tosylate. Borane reduction and arylation, followed by salt formation yielded S-[gamma]-[(4-trifluoromethyl)phenoxy]benzenepropanamine-[1-[sup 14]C] maleate. (Author).

  15. [Efficiency of Brazilian States and the Federal District in the public kidney transplant system based on DEA (Data Envelopment Analysis) and the Malmquist index].

    Science.gov (United States)

    Costa, Cassia Kely Favoretto; Balbinotto Neto, Giácomo; Sampaio, Luciano Menezes Bezerra

    2014-08-01

    The objective of this study was to evaluate the efficiency of Brazilian States and the Federal District in the public kidney transplant system and their productivity trends from 2006 to 2011. The authors used Data Envelopment Analysis (DEA) with slack and the Malmquist index with slack. Inputs included spending on hospital services and health professionals in the system. The output was the number of kidney transplants performed in each State. The data showed a significant discrepancy between States in the number of kidney transplants. The transplant system's inefficiency may result from inadequate management, failure to comply with national guidelines, inactive hospital transplant committees, and overburdened hospital staff. Institutional changes promoted by the Brazilian Ministry of Health (procedures improvement and standardization) failed to increase productivity in most States during this period.

  16. Evaluating the relationship between the photochemical reflectance index and the light use efficiency in a mangrove forest with Spartina alterniflora invasion

    Science.gov (United States)

    Shi, C.; Wang, L.; Yang, S.

    2017-12-01

    Mangrove forest is an important component of wetland ecosystems, which has high productivity, strong carbon sequestration capacity and great ecological values. The light use efficiency (LUE) of photosynthesis is a major parameter for estimating plant productivity. Recent studies have shown that the photochemical reflectance index (PRI) has a strong relationship with LUE and the relationship is significantly influenced by plant species and environmental factors. In this paper, we evaluated the relationship between PRI and LUE for different mangrove species (Avicennia marina and Aegiceras corniculatum) and the effects of Spartina alterniflora invasion on the PRI-LUE relationship. The results showed that the LUE of mangroves had a good correlation with PRI, and the correlation of Avicennia marina was stronger than that of Aegiceras corniculatum. In addition, the invasion of Spartina alterniflora impaired the PRI-LUE relationship for both mangrove species.

  17. Correlation between gamma index passing rate and clinical dosimetric difference for pre-treatment 2D and 3D volumetric modulated arc therapy dosimetric verification.

    Science.gov (United States)

    Jin, X; Yan, H; Han, C; Zhou, Y; Yi, J; Xie, C

    2015-03-01

    To investigate comparatively the percentage gamma passing rate (%GP) of two-dimensional (2D) and three-dimensional (3D) pre-treatment volumetric modulated arc therapy (VMAT) dosimetric verification and their correlation and sensitivity with percentage dosimetric errors (%DE). %GP of 2D and 3D pre-treatment VMAT quality assurance (QA) with different acceptance criteria was obtained by ArcCHECK® (Sun Nuclear Corporation, Melbourne, FL) for 20 patients with nasopharyngeal cancer (NPC) and 20 patients with oesophageal cancer. %DE were calculated from planned dose-volume histogram (DVH) and patients' predicted DVH calculated by 3DVH® software (Sun Nuclear Corporation). Correlation and sensitivity between %GP and %DE were investigated using Pearson's correlation coefficient (r) and receiver operating characteristics (ROCs). Relatively higher %DE on some DVH-based metrics were observed for both patients with NPC and oesophageal cancer. Except for 2%/2 mm criterion, the average %GPs for all patients undergoing VMAT were acceptable with average rates of 97.11% ± 1.54% and 97.39% ± 1.37% for 2D and 3D 3%/3 mm criteria, respectively. The number of correlations for 3D was higher than that for 2D (21 vs 8). However, the general correlation was still poor for all the analysed metrics (9 out of 26 for 3D 3%/3 mm criterion). The average area under the curve (AUC) of ROCs was 0.66 ± 0.12 and 0.71 ± 0.21 for 2D and 3D evaluations, respectively. There is a lack of correlation between %GP and %DE for both 2D and 3D pre-treatment VMAT dosimetric evaluation. DVH-based dose metrics evaluation obtained from 3DVH will provide more useful analysis. Correlation and sensitivity of %GP with %DE for VMAT QA were studied for the first time.

  18. GammaWorkshops Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H. (ed.) (Swedish Defence Research Agency (Sweden)); Straalberg, E. (Institute for Energy Technology, Kjeller (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority, STUK (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (Iceland))

    2012-01-15

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  19. High-Efficiency and High-Color-Rendering-Index Semitransparent Polymer Solar Cells Induced by Photonic Crystals and Surface Plasmon Resonance.

    Science.gov (United States)

    Shen, Ping; Wang, Guoxin; Kang, Bonan; Guo, Wenbin; Shen, Liang

    2018-02-21

    Semitransparent polymer solar cells (ST-PSCs) show attractive potential in power-generating windows or building-integrated photovoltaics. However, the development of ST-PSCs is lagging behind opaque PSCs because of the contradiction between device efficiency and transmission. Herein, Ag/Au alloy nanoparticles and photonic crystals (PCs) were simultaneously introduced into ST-PSCs, acting compatibly as localized surface plasmon resonances and distributed Bragg reflectors to enhance light absorption and transmission. As a result, ST-PSCs based on a hybrid PTB7-Th:PC 71 BM active layer contribute an efficiency as high as 7.13 ± 0.15% and an average visible transmission beyond 20%, which are superior to most of the reported results. Furthermore, PCs can partly compensate valley range of transmission by balancing reflection and transmission regions, yielding a high color rendering index of 95. We believe that the idea of two light management methods compatibly enhancing the performance of ST-PSCs can offer a promising path to develop photovoltaic applications.

  20. A straightforward and efficient method for the synthesis of diversely substituted {beta}-aminoketones and {gamma}-aminoalcohols from 3-(N,N-dimethylamino)propiophenones as starting materials

    Energy Technology Data Exchange (ETDEWEB)

    Abonia, Rodrigo; Arteaga, Danny; Castillo, Juan; Insuasty, Braulio; Quiroga, Jairo; Ortiz, Alejandro, E-mail: rodrigo.abonia@correounivalle.edu.co [Universidad del Valle, Cali (Colombia). Department of Chemistry. Research Group of Heterocyclic Compounds

    2013-09-15

    Libraries of novel {beta}-aminoketones and {gamma}-aminoalcohols showing a wide structural diversity were easily obtained from a simple approach, using 3-(N,N-dimethylamino)propiophenone derivatives as key starting material. The procedure involved initially an N-alkylation of secondary benzylamines with propiophenone salts yielding the desired {beta}-aminoketones. Chemical or catalytic reduction of their carbonyl groups provided the final {gamma}-aminoalcohols in good yields. This protocol proved to be convenient as an alternative route for the synthesis of the local anesthetic Falicain Registered-Sign and for the topic antifungal drug Naftifine Registered-Sign . (author)

  1. Masking of the CD3 gamma di-leucine-based motif by zeta is required for efficient T-cell receptor expression

    DEFF Research Database (Denmark)

    Lauritsen, Jens Peter H; Bonefeld, Charlotte Menné; von Essen, Marina

    2004-01-01

    containing the di-leucine-based endocytosis motif of the TCR subunit CD3 gamma have indicated that the zeta chain can mask this motif. In this study, we show that successive truncations of the cytoplasmic tail of zeta led to reduced surface expression levels of completely assembled TCR complexes. The reduced...... TCR expression levels were caused by an increase in the TCR endocytic rate constant in combination with an unaffected exocytic rate constant. Furthermore, the TCR degradation rate constant was increased in cells with truncated zeta. Introduction of a CD3 gamma chain with a disrupted di-leucine...

  2. Photoperiod and temperature constraints on the relationship between the photochemical reflectance index and the light use efficiency of photosynthesis in Pinus strobus.

    Science.gov (United States)

    Fréchette, Emmanuelle; Chang, Christine Yao-Yun; Ensminger, Ingo

    2016-03-01

    The photochemical reflectance index (PRI) is a proxy for the activity of the photoprotective xanthophyll cycle and photosynthetic light use efficiency (LUE) in plants. Evergreen conifers downregulate photosynthesis in autumn in response to low temperature and shorter photoperiod, and the dynamic xanthophyll cycle-mediated non-photochemical quenching (NPQ) is replaced by sustained NPQ. We hypothesized that this shift in xanthophyll cycle-dependent energy partitioning during the autumn is the cause for variations in the PRI-LUE relationship. In order to test our hypothesis, we characterized energy partitioning and pigment composition during a simulated summer-autumn transition in a conifer and assessed the effects of temperature and photoperiod on the PRI-LUE relationship. We measured gas exchange, chlorophyll fluorescence and leaf reflectance during the photosynthetic downregulation in Pinus strobus L. seedlings exposed to low temperature/short photoperiod or elevated temperature/short photoperiod conditions. Shifts in energy partitioning during simulated autumn were observed when the pools of chlorophylls decreased and pools of photoprotective carotenoids increased. On a seasonal timescale, PRI was controlled by carotenoid pool sizes rather than xanthophyll cycle dynamics. Photochemical reflectance index variation under cold autumn conditions mainly reflected long-term pigment pool adjustments associated with sustained NPQ, which impaired the PRI-LUE relationship. Exposure to warm autumn conditions prevented the induction of sustained NPQ but still impaired the PRI-LUE relationship. We therefore conclude that alternative zeaxanthin-independent NPQ mechanisms, which remain undetected by the PRI, are present under both cold and warm autumn conditions, contributing to the discrepancy in the PRI-LUE relationship during autumn. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Gamma spectrometry of infinite 4Π geometry

    International Nuclear Information System (INIS)

    Nordemann, D.J.R.

    1987-07-01

    Owing to the weak absorption og gamma radiation by matter, gamma-ray spectrometry may be applied to samples of great volume. A very interesting case is that of the gamma-ray spectrometry applied with 4Π geometry around the detector on a sample assumed to be of infinite extension. The determination of suitable efficiencies allows this method to be quantitative. (author) [pt

  4. Marine gamma spectrometric survey

    International Nuclear Information System (INIS)

    Kostoglodov, V.V.

    1979-01-01

    Presented are theoretical problems physical and geochemical prerequisites and possibilities of practical application of the method of continuous submarine gamma-spectrometric survey and radiometric survey destined for rapid study of the surface layer of marine sediments. Shown is high efficiency and advantages of this method in comparison with traditional and widely spread in marine geology methods of bottom sediments investigation

  5. The influence of increasing dietary fat or protein on the efficiency of broiler chickens exposed to low levels of gamma-rays

    International Nuclear Information System (INIS)

    Ezzat, I.E.; Ghazalah, A.A.

    2002-01-01

    A total of 400 one-day-old chicks, from hubbard line of meat production type, were used in this study. The chicks were divided into three nutritional groups. The second group was fed on a high protein feed containing 3% protein higher than that of the normal diet (group one). The fat level was increased by 4% in the feed of the third group over the value of the normal diet. Each group was divided again into four subgroup treatments (To, T1, T2, and T3) according to the exposure to gamma rays in a single or multi doses. The aim of this study was to compare between the nutritional types and its combinations with the applied doses of gamma rays on broiler performance. The results can be summarized as follows: The broiler chicks fed on the high fat ration and exposed to 0.25 Gy of gamma-rays four times (group 111, T3) recorded the highest body weight gain along the duration of the experiment. in general, the stimulation effect of the gamma-ray doses applied herein was obvious during the period of rapid growth (0-4 weeks of age) then it was followed by retardation in growth rate. The group of chicks fed on a diet containing high fat (group 111), achieved the crude fiber and nitrogen extract digestibility's. Increase of dietary protein was accompanied by a significant increase in carcass protein, water and ash content. Carcass fat was increased while carcass water was decreased with low level of gamma rays

  6. ISPA - a high accuracy X-ray and gamma camera Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    ISPA offers ... Ten times better resolution than Anger cameras High efficiency single gamma counting Noise reduction by sensitivity to gamma energy ...for Single Photon Emission Computed Tomography (SPECT)

  7. Gamma astronomy

    International Nuclear Information System (INIS)

    Cesarsky, C.; Cesarsky, J.P.

    1986-01-01

    This article overviews the gamma astronomy research. Sources already observed, and what causes to give to them; the galactic radiation and its interpretation; techniques already used and current projects [fr

  8. Gamma Spectroscopy

    NARCIS (Netherlands)

    Niemantsverdriet, J.W.; Butz, Tilman; Ertl, G.; Knözinger, H.; Schüth, F.

    2008-01-01

    No abstract. The sections in this article are 1 Introduction 2 Mössbauer Spectroscopy 3 Time-Differential Perturbed Angular Correlations (TDPAC) 4 Conclusions and Outlook Keywords: Mössbauer spectroscopy; gamma spectroscopy; perturbed angular correlation; TDPAC

  9. Indexing mergers and acquisitions

    OpenAIRE

    Gang, Jianhua; Guo, Jie (Michael); Hu, Nan; Li, Xi

    2017-01-01

    We measure the efficiency of mergers and acquisitions by putting forward an index (the ‘M&A Index’) based on stochastic frontier analysis. The M&A Index is calculated for each takeover deal and is standardized between 0 and 1. An acquisition with a higher index encompasses higher efficiency. We find that takeover bids with higher M&A Indices are more likely to succeed. Moreover, the M&A Index shows a strong and positive relation with the acquirers’ post-acquisition stock perfo...

  10. Evaluation of the Effect of Rotation and Application Rate of Nitrogen on Yield, Yield Components and Nitrogen Efficiency Indexes in wheat

    Directory of Open Access Journals (Sweden)

    R Nasri

    2016-02-01

    seeding rate of 200 kg ha-1. Soil samples were collected after harvest of each crop from 0 to 30 cm and 31 to 60 cm soil depths using a soil auger. Wheat grain yield (according to 14% moisture obtained by harvesting the central area of 3 in 10 m in each plot. Yield components were determined from two randomly selected areas (2m2 within each plot. Plant samples collected at harvest were separated into grain and straw and oven-dried at 60˚C for 72hr. Biomass and grain sub samples analyzed for total N content using a micro-Kjeldahl digestion with sulfuric acid. The terminology of N efficiency parameters was considered according to Delogu et al, (11 and Lopez-Bellido & Lopez-Bellido, (22, Rahimizadeh et al. (30, Limon-Ortega et al. (20 methods. Results and Discussion The results showed that there were highly significant differences (P ≤ 0.01 in forage yield. There were also significant differences (P ≤ 0.05 in total dry weight, protein content and protein yield between treatments. Perko varieties produced higher fresh and dry matter yield with 69,586 (kg ha-1 and 7147 (kg ha-1, respectively compared to other varieties. Buko varieties showed greater protein percentage with 23.36 compared to the rest of the varieties. The highest and lowest grain yield, with 8345, and 4491 (kg ha-1 were obtained for Buko; wheat rotation and fallow, wheat rotation, respectively. The highest and lowest nitrogen uptake was obtained for Buko; wheat and clover, wheat rotation, respectively. The differences between the rotations were significant for various agronomic nitrogen efficiency. The rotation of oilseed radish and wheat showed greater nitrogen economic performance with 36.20 kg ha-1. By increasing nitrogen rate agronomic performance decreased with the exception in fallow- wheat. Physiological efficiency of nitrogen in fallow-wheat rotation was more than 39 (kg kg-1 of nitrogen. The maximum efficiency of nitrogen recovery was obtained for oilseed radish: wheat and Perko PVH; wheat

  11. Very low dose gamma irradiation stimulates gaseous exchange and carboxylation efficiency, but inhibits vascular sap flow in groundnut (Arachis hypogaea L.).

    Science.gov (United States)

    Ahuja, Sumedha; Singh, Bhupinder; Gupta, Vijay Kumar; Singhal, R K; Venu Babu, P

    2014-02-01

    An experiment was carried out to determine the effect of low dose gamma radiation on germination, plant growth, nitrogen and carbon fixation and carbon flow and release characteristics of groundnut. Dry seeds of groundnut variety Trombay groundnut 37A (TG 37A), a radio mutant type developed by Bhabha Atomic Research Centre (BARC), Mumbai, India, were subjected to the pre-sowing treatment of gamma radiation within low to high dose physiological range, i.e., 0.0, 0.0082, 0.0164. 0.0328, 0.0656, 0.1312, 5, 25, 100, 500 Gray (Gy) from a cobalt source ((60)Co). Observations were recorded for the radiation effect on percentage germination, vigour, gas exchange attributes such as photosynthetic rate, stomatal conductance and transpiration rate, chlorophyll content, root exudation in terms of (14)C release, vascular sap flow rate and activities of rate defining carbon and nitrogen assimilating enzymes such as ribulose-1,5-bisphosphate carboxylase (rubisco) and nitrate reductase (NR). Seed germination was increased by 10-25% at the lower doses up to 5 Gy while the improvement in plant vigour in the same dose range was much higher (22-84%) than the unirradiated control. For radiation exposure above 5 Gy, a dose-dependent decline in germination and plant vigour was measured. No significant effect was observed on the photosynthesis at radiation exposure below 5 Gy but above 5 Gy dose there was a decline in the photosynthetic rate. Stomatal conductance and transpiration rate, however, were only inhibited at a high dose of 500 Gy. Leaf rubisco activity and NR activities remained unaffected at all the investigated doses of gamma irradiation. Mean root exudation and sap flow rate of the irradiated plants, irrespective of the dose, was reduced over the unirradiated control more so in a dose-dependent manner. Results indicated that a very low dose of gamma radiation, in centigray to gray range, did not pose any threat and in fact stimulated metabolic functions in such a way to aid

  12. Efficiency of Gamma Radiation Alone or In Combination With Heat Stress on Metal Contents of Parents and First Generation of Males of The Cotton Leaf Worm Spodoptera Littoralis

    International Nuclear Information System (INIS)

    El-Degwi, M.S.; Alm El-Din, M.M.S.; Hazaa, M.A.M.

    2011-01-01

    The main objective of the present investigation was to determine the influence of gamma radiation either alone or in combination with heat on the contents and concentration of elements detected in the whole body tissue of male parents and F1 generation of Spodoptera littoralis treated as full grown pupae. The doses applied were 75, 100 and 150 Gy. The data revealed the presence of eight elements in parents and F1 generation exposed to different heat stress (27±2, 33 and 37 degree C and P and Mg were the major contents. The obtained data indicated also that there were no differences in the composition of individual elements between male parents and male F1 generation. There were differences in relative concentration which depends on irradiation dose. The combination treatments were effective on elements concentration. The total concentration of light elements of male parents and F1 generation was increased by increasing the radiation dose. In the contrary, the concentration of heavy element was decreased by increasing the radiation dose. It could be concluded that gamma radiation and/or heat was effective on elements concentrations in adult body of male parents and F1 generation of Spodoptera littoralis which served as biological indicator of normal metabolic pathways and/or biological activity.

  13. THE SPECTRAL INDEX PROPERTIES OF FERMI BLAZARS

    Energy Technology Data Exchange (ETDEWEB)

    Fan, J. H.; Yang, J. H.; Yuan, Y. H.; Wang, J.; Gao, Y., E-mail: jhfan_cn@yahoo.com.cn [Center for Astrophysics, Guangzhou University, Guangzhou 510006 (China)

    2012-12-20

    In this paper, a sample of 451 blazars (193 flat spectrum radio quasars (FSRQs), 258 BL Lacertae objects) with corresponding X-ray and Fermi {gamma}-ray data is compiled to investigate the correlation both between the X-ray spectral index and the {gamma}-ray spectral index and between the spectral index and the luminosity, and to compare the spectral indexes {alpha}{sub X}, {alpha}{sub {gamma}}, {alpha}{sub X{gamma}}, and {alpha}{sub {gamma}X{gamma}} for different subclasses. We also investigated the correlation between the X-ray and the {gamma}-ray luminosity. The following results have been obtained. Our analysis indicates that an anti-correlation exists between the X-ray and the {gamma}-ray spectral indexes for the whole sample. However, when we considered the subclasses of blazars (FSRQs, the low-peaked BL Lacertae objects (LBLs) and the high-peaked BL Lacertae objects (HBLs)) separately, there is not a clear relationship for each subclass. Based on the Fermi-detected sources, we can say that the HBLs are different from FSRQs, while the LBLs are similar to FSRQs.

  14. Browse Title Index

    African Journals Online (AJOL)

    Items 851 - 900 of 1255 ... Vol 16, No 4 (2010), Origin and generation mechanisms of ... Vol 13, No 4 (2007), Osmotic fragility index of HBAA red blood cells in the presence of ... (2004), Photovoltaic cells, efficiency and optimization, Abstract PDF.

  15. Gamma camera

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    The light pulse output of a scintillator, on which incident collimated gamma rays impinge, is detected by an array of photoelectric tubes each having a convexly curved photocathode disposed in close proximity to the scintillator. Electronic circuitry connected to outputs of the phototubes develops the scintillation event position coordinate electrical signals with good linearity and with substantial independence of the spacing between the scintillator and photocathodes so that the phototubes can be positioned as close to the scintillator as is possible to obtain less distortion in the field of view and improved spatial resolution as compared to conventional planar photocathode gamma cameras

  16. Formulation of the relationship between indices of neutron-gamma and gamma-gamma method and the percentrage of iron

    International Nuclear Information System (INIS)

    Majorowicz, J.

    1973-01-01

    In this article, the author presents the possibility of a complex utilization of radiometric logging methods, neutron-gamma profiling and gamma-gamma density logging for determining percentage of iron and establishing geophysical possibilities of identifying zones of economically profitable ores in borehole profiles. Figures present the correlations between indices of neutron-gamma and gamma-gamma logging methods and the percentage of iron, as well as the correlation of neutron-gamma and gamma-gamma indices for zones minerallized with iron ores. The article presents the correlational analyses of the results: the correlational coefficients are given as well as total error in determining iron content on the basis of each of the methods described. Next, a multidimensional statistical analysis is carried out on the results obtained. On the basis of the two-dimensional correlational coefficients calculated and the average standard deviation, an equation of linear regression was formulated, simultaneously involving three parameters - the indices of neutron-gamma and gamma-gamma logging and the percentage of iron. The multiple correlational coefficient obtained markedly exceeds the two-dimentional correlation coefficient (r=0.974>rsub(xz)>rsub(yz)>rsub(xy)). The given method of utilizing multidimensional statistics in borehole geophysics for identifying iron ores is an efficient one. On the basis of several relationships among independent variables which are less obvious (smaller values of correlational coefficient), it is possible to obtain a single distinct relationship involving all variables simultaneously. (author)

  17. Efficient oxidative desulfurization (ODS) of model fuel with H{sub 2}O{sub 2} catalyzed by MoO{sub 3}/{gamma}-Al{sub 2}O{sub 3} under mild and solvent free conditions

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Yuhua; Li, Gang; Ning, Guiling [State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology (China)

    2011-01-15

    An efficient process to remove organic sulfur compounds from model fuel has been explored. Dibenzothiophene (DBT) and 4, 6-dimethyldibenzothiophene (4, 6-DMDBT) can be completely oxidized into their corresponding sulfones by H{sub 2}O{sub 2} over 14 wt.% MoO{sub 3}/{gamma}-Al{sub 2}O{sub 3} catalyst under mild conditions in 15 min. The effects of solvent, initial sulfide concentration, loading of MoO{sub 3} and amount of catalyst on oxidative removal of DBT were studied. The employments of solvents have decreased the reaction rate of DBT, which can be attributed to the competitive adsorption between the sulfide and solvent. The oxidative reactivity increases in the order of thiophene (Th) < benzothiophene (BT) < DBT < 4, 6-DMDBT. The catalyst can be regenerated by methanol washing at 333 K. (author)

  18. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  19. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  20. Establishment of an efficient fermentation system of gamma-aminobutyric acid by a lactic acid bacterium, Enterococcus avium G-15, isolated from carrot leaves.

    Science.gov (United States)

    Tamura, Takayoshi; Noda, Masafumi; Ozaki, Moeko; Maruyama, Masafumi; Matoba, Yasuyuki; Kumagai, Takanori; Sugiyama, Masanori

    2010-01-01

    In the present study, we successfully isolated a carrot leaf-derived lactic acid bacterium that produces gamma-aminobutyric acid (GABA) from monosodium L-glutamate (L-MSG) at a hyper conversion rate. The GABA-producing bacterium, identified as Enterococcus (E.) avium G-15, produced 115.7±6.4 g/l GABA at a conversion rate of 86.0±5.0% from the added L-MSG under the optimum culture condition by a continuous L-MSG feeding method using a jar-fermentor, suggesting that the bacterium displays a great potential ability for the commercial-level fermentation production of GABA. Using the reverse transcription polymerase chain reaction (RT-PCR) method, we analyzed the expression of genes for the GABA transporter and glutamate decarboxylase, designated gadT and gadG, respectively, which were cloned from the E. avium G-15 chromosome. Both genes were expressed even without the added L-MSG, but their expression was enhanced by the addition of L-MSG.

  1. AUTHOR INDEX

    Indian Academy of Sciences (India)

    applications to nonlinear evolution equations ... Crystal growth, FTIR and thermal characteri- ... beam in an unmagnetized electron–positron– ... and kerma of gamma radiation for oxides of ... on the optical properties in a single quantum.

  2. Economics of gamma irradiation processing

    International Nuclear Information System (INIS)

    Tani, Toshio

    1980-01-01

    The gamma-ray irradiation business started at the Takasaki Laboratory of Japan Atomic Energy Research Institute. The irradiation facilities were constructed thereafter at various sites. The facilities must accept various types of irradiation, and must be constructed as multi-purpose facilities. The cost of irradiation consists of the cost of gamma sources, construction expense, personnel expense, management expense, and bank interest. Most of the expenses are considered to be fixed expense, and the amount of irradiation treatment decides the original costs of work. The relation between the irradiation dose and the construction expense shows the larger facility is more economical. The increase of amount of treatment reduces the original cost. The utilization efficiency becomes important when the amount of treatment and the source intensity exceed some values. The principal subjects of gamma-ray irradiation business are the sterilization of medical tools and foods for aseptic animals, the improvement of quality of plastic goods, and the irradiation of foods. Among them, the most important subject is the sterilization of medical tools. The cost of gamma irradiation per m 3 in still more expensive than that by ethylene oxide gas sterilization. However, the demand of gamma-ray irradiation is increasing. For the improvement of quality of plastic goods, electron irradiation is more favourable than the gamma irradiation. In near future, the economical balance of gamma irradiation can be achieved. (Kato, T.)

  3. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  4. Efficiency and Productivity of County-level Public Hospitals Based on the Data Envelopment Analysis Model and Malmquist Index in Anhui, China

    Directory of Open Access Journals (Sweden)

    Nian-Nian Li

    2017-01-01

    Conclusions: In 2010–2015, the relative service efficiency of 12 county-level public hospitals in Anhui Province showed a decreasing trend, and the service efficiency of each hospital changed. In the past 6 years, although some hospitals have been effective, the efficiency of the county-level public hospitals in Anhui Province has not improved significantly, and the total factor productivity has not been effectively improved. County-level public hospitals need to combine their own reality to find their own deficiencies.

  5. EFFICIENCY OF WHEAT, BARLEY AND CORN BRAN TREATED WITH GAMMA RAYS IMPROVING BIOCHEMICAL AND HISTOLOGICAL DISORDERS INDUCED BY FEEDING RATS OXIDIZED OIL

    International Nuclear Information System (INIS)

    SOLIMAN, S.M.; HAMZA, R.G.

    2009-01-01

    The present study aims to investigate the effect of adding 3 different dietary fibers (wheat, barley and corn bran) to normal balanced diet after exposure to gamma radiation at dose of 20 kGy before adding cotton seed oils and boiled oil. The experimental diet was fed for 4 weeks. This study was designed to throw more light on certain biochemical and histological changes in liver of male albino rats. Rats were classified into 8 groups; control group fed on diet fibers free, group 2 fed on diet supplemented with 15% fibers (wheat, barley and corn bran), group 3 fed on diet supplemented with irradiated fibers, group 4 fed on diet supplemented with 15% boiled oil, group 5 fed on diet supplemented with 15% fiber and 15% boiled oil, group 6 fed on diet supplemented with fibers and cotton seed oil 15%, group 7 fed on diet supplemented with irradiated fibers and boiled oil 15% and group 8 fed on diet supplemented with irradiated fibers and cotton seed oil 15%. Experimental investigations were carried out after 4 weeks. The results obtained revealed that extended administration of fibers and cotton seed oil has significantly minimized the amount of thiobarbituric acid reactive substances (TBARS) in blood and significantly ameliorated the glutathion content. Superoxide dismutas and catalase enzymes were assayed in blood, aspartate aminotransferase (AST) and alanine aminotransferase (ALT) were detected. In addition, modulations of cholesterol and triglycerides levels were observed through all the experiments. In rats fed on boiled oil, the data showed histological changes in liver such as tissue degeneration, lymphocyte infiltration, hepatic cell necrosis and dilation of portal spaces and blood vessels.

  6. Gamma camera

    International Nuclear Information System (INIS)

    Reiss, K.H.; Kotschak, O.; Conrad, B.

    1976-01-01

    A gamma camera with a simplified setup as compared with the state of engineering is described permitting, apart from good localization, also energy discrimination. Behind the usual vacuum image amplifier a multiwire proportional chamber filled with trifluorine bromium methane is connected in series. Localizing of the signals is achieved by a delay line, energy determination by means of a pulse height discriminator. With the aid of drawings and circuit diagrams, the setup and mode of operation are explained. (ORU) [de

  7. Gamma irradiator

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  8. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1987-06-01

    The mapping of gamma sources radiation emission in a nuclear plant is an important safety point. A remote gamma ray mapping process was developed in SPS/CEA/SACLAY. It uses the ''pinhole camera'' principle, precursor of photography. It mainly consists of a radiation proof box, with a small orifice, containing sensitive emulsions at the opposite. A first conventional photographic type emulsion photographs the area. A second photographic emulsion shows up the gamma radiations. The superim position of the two shots gives immediate informations of the precise location of each source of radiation in the observed area. To make easier the presentation and to improve the accuracy of the results for radiation levels mapping, the obtained films are digitally processed. The processing assigns a colours scale to the various levels of observed radiations. Taking account physical data and standard parameters, it gets possible to estimate the dose rate. The device is portable. Its compactness and fully independent nature make it suitable for use anywhere. It can be adapted to a remote automatic handling system, robot... so as to avoid all operator exposure when the local dose rate is too high [fr

  9. Gamma irradiation treatment of secondary sewage effluent

    International Nuclear Information System (INIS)

    Vajdic, A.H.

    The operation and monitoring of a pilot scale Co-60 gamma irradiation unit treating secondary sewage effluent is described. The disinfecting efficiency of the unit is compared to that of an experimental 'ideal' chlorination unit and to the plant chlorination process. A cost estimate for disinfection by gamma irradiation on a full plant scale is included. (author)

  10. Fabrication of silicon solar cell with >18% efficiency using spin-on-film processing for phosphorus diffusion and SiO{sub 2}/graded index TiO{sub 2} anti-reflective coating

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yi-Yu; Ho, Wen-Jeng, E-mail: wjho@ntut.edu.tw; Yeh, Chien-Wu

    2015-11-01

    Highlights: • Employed SOF technology for both phosphorus diffusion and multi-layer ARCs. • Optical properties of TiO{sub 2}, SiO{sub 2}, and SiO{sub 2}/TiO{sub 2}/TiO{sub 2} films are characterized. • Photovoltaic performances of the fabricated solar cells are measured and compared. • An impressive efficiency of 18.25% was obtained by using the SOF processes. - Abstract: This study employed spin-on film (SOF) technology for the fabrication of phosphorus diffusion and multi-layer anti-reflective coatings (ARCs) with a graded index on silicon (Si) wafers. Low cost and high efficiency solar cells are important issues for the operating cost of a photovoltaic system. SOF technology for the fabrication of solar cells can be for the achievement of this goal. This study succeeded in the application of SOF technology in the preparation of both phosphorus diffusion and SiO{sub 2}/graded index TiO{sub 2} ARCs for Si solar cells. Optical properties of TiO{sub 2}, SiO{sub 2}, and multi-layer SiO{sub 2}/TiO{sub 2} deposition by SOF are characterized. Electrical and optical characteristics of the fabricated solar cells are measured and compared. An impressive efficiency of 18.25% was obtained by using the SOF processes.

  11. Efficacy of gamma sterilization technique for biofertilizer carrier production

    International Nuclear Information System (INIS)

    Rallos, Roland V.; Rivera, Faye G.; Anarna, Julie A.; Rojales, Jacqueline S.

    2013-01-01

    Th use of gamma irradiation as sterilization technique for biofertilizer carrier is very efficient and practical especially in large scale production. The results of this study on the efficacy of gamma sterilization justify research on the effects of established doses of gamma irradiation on the physico-chemical properties of the clay-charcoal mixture

  12. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    To set the gamma activity cartography is an important element of safety in numerous cases: intervention in hot cell, search of a radioactive source, examination of radioactive waste circuit followed by a reprocessing definition of decontamination and decommissioning processes and for all other accidents. The device presented here is like a ''black box'' with an aperture and an emulsion photosensitive to the opposite; a classical film takes photography of the place; a X-ray type emulsion gives a spot more or less contrasted and extensive corresponding to each source. Images can be processed with a microprocessor [fr

  13. An assessment of the efficiency of methods for measurement of the computed tomography dose index (CTDI) for cone beam (CBCT) dosimetry by Monte Carlo simulation.

    Science.gov (United States)

    Abuhaimed, Abdullah; J Martin, Colin; Sankaralingam, Marimuthu; J Gentle, David; McJury, Mark

    2014-11-07

    The IEC has introduced a practical approach to overcome shortcomings of the CTDI100 for measurements on wide beams employed for cone beam (CBCT) scans. This study evaluated the efficiency of this approach (CTDIIEC) for different arrangements using Monte Carlo simulation techniques, and compared CTDIIEC to the efficiency of CTDI100 for CBCT. Monte Carlo EGSnrc/BEAMnrc and EGSnrc/DOSXYZnrc codes were used to simulate the kV imaging system mounted on a Varian TrueBeam linear accelerator. The Monte Carlo model was benchmarked against experimental measurements and good agreement shown. Standard PMMA head and body phantoms with lengths 150, 600, and 900 mm were simulated. Beam widths studied ranged from 20-300 mm, and four scanning protocols using two acquisition modes were utilized. The efficiency values were calculated at the centre (εc) and periphery (εp) of the phantoms and for the weighted CTDI (εw). The efficiency values for CTDI100 were approximately constant for beam widths 20-40 mm, where εc(CTDI100), εp(CTDI100), and εw(CTDI100) were 74.7  ±  0.6%, 84.6  ±  0.3%, and 80.9  ±  0.4%, for the head phantom and 59.7  ±  0.3%, 82.1  ±  0.3%, and 74.9  ±  0.3%, for the body phantom, respectively. When beam width increased beyond 40 mm, ε(CTDI100) values fell steadily reaching ~30% at a beam width of 300 mm. In contrast, the efficiency of the CTDIIEC was approximately constant over all beam widths, demonstrating its suitability for assessment of CBCT. εc(CTDIIEC), εp(CTDIIEC), and εw(CTDIIEC) were 76.1  ±  0.9%, 85.9  ±  1.0%, and 82.2  ±  0.9% for the head phantom and 60.6  ±  0.7%, 82.8  ±  0.8%, and 75.8  ±  0.7%, for the body phantom, respectively, within 2% of ε(CTDI100) values for narrower beam widths. CTDI100,w and CTDIIEC,w underestimate CTDI∞,w by ~55% and ~18% for the head phantom and by ~56% and ~24% for the body phantom, respectively, using a clinical beam width 198 mm. The

  14. Energy efficiency as a unifying principle for human, environmental, and global health [v1; ref status: indexed, http://f1000r.es/y8

    Directory of Open Access Journals (Sweden)

    Luigi Fontana

    2013-04-01

    Full Text Available A strong analogy exists between over/under consumption of energy at the level of the human body and of the industrial metabolism of humanity. Both forms of energy consumption have profound implications for human, environmental, and global health. Globally, excessive fossil-fuel consumption, and individually, excessive food energy consumption are both responsible for a series of interrelated detrimental effects, including global warming, extreme weather conditions, damage to ecosystems, loss of biodiversity, widespread pollution, obesity, cancer, chronic respiratory disease, and other lethal chronic diseases. In contrast, data show that the efficient use of energy—in the form of food as well as fossil fuels and other resources—is vital for promoting human, environmental, and planetary health and sustainable economic development. While it is not new to highlight how efficient use of energy and food can address some of the key problems our world is facing, little research and no unifying framework exists to harmonize these concepts of sustainable system management across diverse scientific fields into a single theoretical body. Insights beyond reductionist views of efficiency are needed to encourage integrated changes in the use of the world’s natural resources, with the aim of achieving a wiser use of energy, better farming systems, and healthier dietary habits. This perspective highlights a range of scientific-based opportunities for cost-effective pro-growth and pro-health policies while using less energy and natural resources.

  15. Neutron detection gamma ray sensitivity criteria

    International Nuclear Information System (INIS)

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Mace, Emily K.; Stephens, Daniel L.; Woodring, Mitchell L.

    2011-01-01

    The shortage of 3 He has triggered the search for effective alternative neutron detection technologies for national security and safeguards applications. Any new detection technology must satisfy two basic criteria: (1) it must meet a neutron detection efficiency requirement, and (2) it must be insensitive to gamma-ray interference at a prescribed level, while still meeting the neutron detection requirement. It is the purpose of this paper to define measureable gamma ray sensitivity criteria for neutron detectors. Quantitative requirements are specified for: intrinsic gamma ray detection efficiency and gamma ray absolute rejection. The gamma absolute rejection ratio for neutrons (GARRn) is defined, and it is proposed that the requirement for neutron detection be 0.9 3 He based neutron detector is provided showing that this technology can meet the stated requirements. Results from tests of some alternative technologies are also reported.

  16. Gamma knife

    International Nuclear Information System (INIS)

    Kawamoto, Shunsuke; Takakura, Kintomo

    1991-01-01

    As to the gamma knife which is the radiation surgery device developed in Sweden a quarter century ago, its principle, structure, treatment techniques, already established clinical effect and the problems being left for hereafter are described. This treatment means supplements the operation under microscopes, and at present it takes the important position in neurosurgery, but hereafter, by the interdisciplinary cooperation of neurosurgery and clinical radiobiology, the more development can be expected. The method of irradiating the radiation of high dose selectively to a target region and breaking its tissue is called radiosurgery, and the device developed for this purpose is the gamma knife. First, it was applied to functional diseases, but good results were obtained by its application to auditory nerve and brain blood vessels, and it establishes the position as the safe treatment method of the morbid state in the deep part of brains, which is difficult to reach by operation. Accompanying the recent progress of the operation of skull base part, attention is paid to its application to various tumors in skull base. On the other hand, the radiosurgery combining a cyclotron or a linear accelerator with stereotaxic brain surgery is actively tried mainly to the deformation of brain blood vessels. (K.I.)

  17. Walkability Index

    Science.gov (United States)

    The Walkability Index dataset characterizes every Census 2010 block group in the U.S. based on its relative walkability. Walkability depends upon characteristics of the built environment that influence the likelihood of walking being used as a mode of travel. The Walkability Index is based on the EPA's previous data product, the Smart Location Database (SLD). Block group data from the SLD was the only input into the Walkability Index, and consisted of four variables from the SLD weighted in a formula to create the new Walkability Index. This dataset shares the SLD's block group boundary definitions from Census 2010. The methodology describing the process of creating the Walkability Index can be found in the documents located at ftp://newftp.epa.gov/EPADataCommons/OP/WalkabilityIndex.zip. You can also learn more about the Smart Location Database at https://edg.epa.gov/data/Public/OP/Smart_Location_DB_v02b.zip.

  18. Effect of Gamma Radiation on Nutritional Indices of Larval and Adults Stages of Tribolium castaneum (Coleoptera: Tenebrionidae)

    International Nuclear Information System (INIS)

    Ahmadi, M.; Moharramipour, S.

    2012-01-01

    In this study antifeedant effect of different doses of gamma radiation as a controlling safe method on flour weevil, Tribolium castaneum (Herbst) larvae and adult was studied. Doses of 100, 400, 600, 800 and 1000 Gy of gamma radiation were used and after 72 hours, nutritional indices were evaluated. The relative growth rate, relative consumption rate, efficiency of conversion of ingested food and feeding deterrence index as nutritional indices were evaluated. Treatments were assessed by flour wheat disc at 27±1 d egree C and 65 p ercent h umidity in a dark condition. The results showed that the relative growth rate of flour weevil larvae and adults decreased significantly (P<0.05) by gamma radiation and the severity of this reduction in larvae was higher than the adults. Although the relative growth rates decreased in adults, this rate in doses of 400, 600, 800 and 1000 Gy showed no significant difference. The relative food consumption rate also decreased with the gamma radiation and its value found to be inversely proportional to the dose radiation. Our experiments showed that the use of gamma radiation exposure to 800 Gy had no significant effect on the efficiency of conversion of ingested food of larvae and reduction was observed only when the gamma radiation was used in 1000 Gy. The feeding deterrence effect of gamma radiation, especially on the larvae was high but no significant difference between doses of 100 to 800 Gy was observed. The results showed that gamma radiation that induces antifeedant effect can be applied as an effective method in control of T. castaneum.

  19. Measurement of the efficient cross section of the reaction {sup 7}Be(p, {gamma}){sup 8}B at low energies and implications in the problem of solar neutrinos; Mesures de la section efficace de la reaction {sup 7}Be(p,{gamma}){sup 8}B a basses energies et implications dans le probleme des neutrinos solaires

    Energy Technology Data Exchange (ETDEWEB)

    Hammache, Fairouz

    1999-07-01

    The {sup 8}B produced inside the sun through the reaction {sup 7}Be(p,{gamma}){sup 8}B is the main, and even unique, source of high energy neutrinos detected in most solar neutrino detection experiments, except with Gallex and Sage. These experiments have all measured a neutrinos flux lower than the one predicted by solar models. Several explanations have been proposed to explain this deficit, but all require a precise knowledge of the efficient cross-section of the reaction {sup 7}Be(p,{gamma}){sup 8}B, because the neutrinos flux of {sup 8}B is directly proportional to this reaction. The direct measurement of this cross section for the solar energy is impossible because of its low value (about 1 femto-barn). In order to get round this problem, the cross sections are measured at higher energy and extrapolated to the solar energy using a theoretical energy dependence. The 6 previous experimental determinations of the efficient cross section were shared in two distinct groups with differences of about 30% which leads to an uncertainty of the same order on the high energy neutrinos flux. The re-measurement of the cross section of this reaction with a better precision is thus of prime importance. A direct measurement of the cross section in the energy range comprised between 0.35 and 1.4 MeV (cm) has been performed first. These experiments have permitted the precise measurement of each parameter involved in the determination of the cross section. Then, measurements of the cross section have been carried out with the PAPAP accelerator at 185.8, 134.7 and 111.7 keV, the lowest mass center energy never reached before. The results are in excellent agreement with those obtained at higher energies. The value obtained by extrapolation of these data for the astrophysical factor S{sub 17}(0) is 19.21.3 EV-B, which leads to a significant reduction of the uncertainty on the high energy neutrinos flux of {sup 8}B. (J.S.)

  20. Natural background gamma-ray spectrum. List of gamma-rays ordered in energy from natural radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Ichimiya, Tsutomu [Japan Radioisotope Association, Tokyo (Japan); Narita, Tsutomu; Kitao, Kensuke

    1998-03-01

    A quick index to {gamma}-rays and X-rays from natural radionuclides is presented. In the list, {gamma}-rays are arranged in order of increasing energy. The list also contains {gamma}-rays from radioactive nuclides produced in a germanium detector and its surrounding materials by interaction with cosmic neutrons, as well as direct {gamma}-rays from interaction with the neutrons. Artificial radioactive nuclides emitting {gamma}-rays with same or near energy value as that of the natural {gamma}-rays and X-rays are also listed. In appendix, {gamma}-ray spectra from a rock, uranium ore, thorium, monazite and uraninite and also background spectra obtained with germanium detectors placed in iron or lead shield have been given. The list is designed for use in {gamma}-ray spectroscopy under the conditions of highly natural background, such as in-situ environmental radiation monitoring or low-level activity measurements, with a germanium detector. (author)

  1. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  2. Specialized software utilities for gamma ray spectrometry. Final report of a co-ordinated research project 1996-2000

    International Nuclear Information System (INIS)

    2002-03-01

    A Co-ordinated Research Project (CRP) on Software Utilities for Gamma Ray Spectrometry was initiated by the International Atomic Energy Agency in 1996 for a three year period. In the CRP several basic applications of nuclear data handling were assayed which also dealt with the development of PC computer codes for various spectrometric purposes. The CRP produced several software packages: for the analysis of low level NaI spectra; user controlled analysis of gamma ray spectra from HPGe detectors; a set of routines for the definition of the detector resolution function and for the unfolding of experimental annihilation spectra; a program for the generation of gamma ray libraries for specific applications; a program to calculate true coincidence corrections; a program to calculate full-energy peak efficiency calibration curve for homogenous cylindrical sample geometries including self-attenuation correction; and a program for the library driven analysis of gamma ray spectra and for the quantification of radionuclide content in samples. In addition, the CRP addressed problems of the analysis of naturally occurring radioactive soil material gamma ray spectra, questions of quality assurance and quality control in gamma ray spectrometry, and verification of the expert system SHAMAN for the analysis of air filter spectra obtained within the framework of the Comprehensive Nuclear Test Ban Treaty. This TECDOC contains 10 presentations delivered at the meeting with the description of the software developed. Each of the papers has been indexed separately

  3. Índice híbrido de eficácia e eficiência para lojas de varejo Effectiveness and efficiency hibrid index for retail stores

    Directory of Open Access Journals (Sweden)

    Denise Santos de Figueiredo

    2009-06-01

    Full Text Available As análises de desempenho atualmente utilizadas no varejo se atêm à avaliação dos diversos índices de desempenho de forma isolada. A metodologia de Análise Envoltória de Dados - DEA oferece a possibilidade de geração de um índice de eficiência único e mais completo, tendo como base a razão ponderada entre os produtos gerados e os insumos necessários para tal. Diferentemente de outras técnicas estatísticas, que utilizam medidas de tendência central para avaliação e comparação de unidades produtivas entre si, a metodologia DEA as compara às melhores, proporcionando assim oportunidades de benchmark, mostrando-se com isso, mais rica no apoio à decisão. Considerar no modelo a opinião dos especialistas, principalmente no que diz respeito à eficácia, se torna um ponto imperativo na atualidade, para conferir credibilidade aos resultados e fazer isso de forma mais simples é um diferencial. A criação e a simulação de unidades produtivas artificiais, ou não observadas, mostram-se como uma alternativa viável e vantajosa para incorporação do conceito de eficácia ao modelo DEA, frente aos problemas com que se pode defrontar ao optar por restrições aos pesos. Esse artigo apresenta a aplicação de todos os pontos até então comentados a um caso real do varejo, propondo um índice único de avaliação de lojas com base na metodologia DEA, incorporando por meio de unidades produtivas artificiais a opinião dos especialistas referentes à eficácia.Nowadays, various methodologies are utilized to analyze and measure performance in retail industries. Data Envelopment Analysis (DEA offers analysts and retailers a unique, thorough, and more meaningful way of measuring performance. The DEA based index uses the ratio between the products generated and resources used. Unlike other statistical techniques that utilize measures of central tendency for evaluation and comparison of productive stores among themselves, DEA methodology

  4. Gamma irradiators for radiation processing

    International Nuclear Information System (INIS)

    2006-01-01

    Radiation technology is one of the most important fields which the IAEA supports and promotes, and has several programmes that facilitate its use in the developing Member States. In view of this mandate, this Booklet on 'Gamma Irradiators for Radiation Processing' is prepared which describes variety of gamma irradiators that can be used for radiation processing applications. It is intended to present description of general principles of design and operation of the gamma irradiators available currently for industrial use. It aims at providing information to industrial end users to familiarise them with the technology, with the hope that the information contained here would assist them in selecting the most optimum irradiator for their needs. Correct selection affects not only the ease of operation but also yields higher efficiency, and thus improved economy. The Booklet is also intended for promoting radiation processing in general to governments and general public

  5. Terrestrial gamma-ray flashes

    Science.gov (United States)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-08-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models.

  6. Terrestrial gamma-ray flashes

    International Nuclear Information System (INIS)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-01-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models

  7. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  8. Cosmic gamma-ray burst

    International Nuclear Information System (INIS)

    Yamagami, Takamasa

    1985-01-01

    Ballon experiments for searching gamma-ray burst were carried out by employing rotating-cross modulation collimators. From a very long observation of total 315 hours during 1975 to 1979, three gamma-ray intensity anomalies were observed which were speculated as a gamma-ray burst. As for the first gamma-ray intensity anomaly observed in 1975, the burst source could be located precisely but the source, heavenly body, could not be specified. Gamma-ray burst source estimation was made by analyzing distribution of burst source in the celestial sphere, burst size distribution, and burst peak. Using the above-mentioned data together with previously published ones, apparent inconsistency was found between the observed results and the adopted theory that the source was in the Galaxy, and this inconsistency was found due to the different time profiles of the burst observed with instruments of different efficiency. It was concluded by these analysis results that employment of logN - logP (relation between burst frequency and burst count) was better than that of logN - logS (burst size) in the examination of gamma-ray burst because the former was less uncertain than the latter. Analyzing the author's observed gamma-ray burst data and the related published data, it was clarified that the burst distribution was almost P -312 for the burst peak value larger than 10 -6 erg/cm 2 .sec. The author could indicate that the calculated celestial distribution of burst source was consistent with the observed results by the derivation using the logN - logP relationship and that the burst larger than 10 -6 erg/cm 2 .sec happens about one thousand times a year, about ten times of the previous value. (Takagi, S.)

  9. High efficiency generalized transduction in Escherichia coli O157:H7 [v1; ref status: indexed, http://f1000r.es/8f

    Directory of Open Access Journals (Sweden)

    Martin G Marinus

    2013-01-01

    Full Text Available Genetic manipulation in enterohemorrhagic E. coli O157:H7 is currently restricted to recombineering, a method that utilizes the recombination system of bacteriophage lambda, to introduce gene replacements and base changes inter alia into the genome. Bacteriophage 933W is a prophage in E. coli O157:H7 strain EDL933, which encodes the genes (stx2AB for the production of Shiga toxin which is the basis for the potentially fatal Hemolytic Uremic Syndrome in infected humans. We replaced the stx2AB genes with a kanamycin cassette using recombineering. After induction of the prophage by ultra-violet light, we found that bacteriophage lysates were capable of transducing to wildtype, point mutations in the lactose, arabinose and maltose genes. The lysates could also transduce tetracycline resistant cassettes. Bacteriophage 933W is also efficient at transducing markers in E. coli K-12. Co-transduction experiments indicated that the maximal amount of transferred DNA was likely the size of the bacteriophage genome, 61 kB. All tested transductants, in both E. coli K-12 and O157:H7, were kanamycin-sensitive indicating that the transducing particles contained host DNA.

  10. Moderate efficiency of clinicians' predictions decreased for blurred clinical conditions and benefits from the use of BRASS index. A longitudinal study on geriatric patients' outcomes.

    Science.gov (United States)

    Signorini, Giulia; Dagani, Jessica; Bulgari, Viola; Ferrari, Clarissa; de Girolamo, Giovanni

    2016-01-01

    Accurate prognosis is an essential aspect of good clinical practice and efficient health services, particularly for chronic and disabling diseases, as in geriatric populations. This study aims to examine the accuracy of clinical prognostic predictions and to devise prediction models combining clinical variables and clinicians' prognosis for a geriatric patient sample. In a sample of 329 consecutive older patients admitted to 10 geriatric units, we evaluated the accuracy of clinicians' prognosis regarding three outcomes at discharge: global functioning, length of stay (LoS) in hospital, and destination at discharge (DD). A comprehensive set of sociodemographic, clinical, and treatment-related information were also collected. Moderate predictive performance was found for all three outcomes: area under receiver operating characteristic curve of 0.79 and 0.78 for functioning and LoS, respectively, and moderate concordance, Cohen's K = 0.45, between predicted and observed DD. Predictive models found the Blaylock Risk Assessment Screening Score together with clinicians' judgment relevant to improve predictions for all outcomes (absolute improvement in adjusted and pseudo-R(2) up to 19%). Although the clinicians' estimates were important factors in predicting global functioning, LoS, and DD, more research is needed regarding both methodological aspects and clinical measurements, to improve prognostic clinical indices. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Application of gamma-gamma logging in predicting anomalous geodynamic phenomena in hard coal mines

    International Nuclear Information System (INIS)

    Blaha, F.; Keclik, L.

    1980-01-01

    The application is discussed of gamma-gamma logging in the prediction of dynamic events like coal and gas bursts, coal sliding in medium dip seams and rock bumps. The overall analysis of the applied rock characterization method and of the measurement results shows that the prediction possibilities of dynamic events are partly limited due to specific effects of the rock massive. In these cases, however, unambiguous results may be obtained by other geophysical methods such as seismoacoustic testing etc. In most cases, however, the gamma-gamma logging results may be used for estimating the degree of dynamic events or checking the efficiency of preventive measures in the locality under investigation. (author)

  12. Extragalactic Gamma-Ray Astrophysics

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    During the last decades, various classes of radio-loud active galactic nuclei have been established as sources of high-energy radiation extending over a very broad range from soft gamma-rays (photon energies E~MeV) up to very-high-energy gamma-rays (E>100 GeV). These include blazars of different types, as well as young and evolved radio galaxies. The observed gamma-ray emission from such implies efficient particle acceleration processes taking place in highly magnetized and relativistic jets produced by supermassive black holes, processes that have yet to be identified and properly understood. In addition, nearby starforming and starburst galaxies, some of which host radio-quiet Seyfert-type nuclei, have been detected in the gamma-ray range as well. In their cases, the observed gamma-ray emission is due to non-thermal activity in the interstellar medium, possibly including also a contribution from accretion disks and nuclear outflows. Finally, the high-energy emission from clusters of galaxies remains elusive...

  13. Sampling Polya-Gamma random variates: alternate and approximate techniques

    OpenAIRE

    Windle, Jesse; Polson, Nicholas G.; Scott, James G.

    2014-01-01

    Efficiently sampling from the P\\'olya-Gamma distribution, ${PG}(b,z)$, is an essential element of P\\'olya-Gamma data augmentation. Polson et. al (2013) show how to efficiently sample from the ${PG}(1,z)$ distribution. We build two new samplers that offer improved performance when sampling from the ${PG}(b,z)$ distribution and $b$ is not unity.

  14. AA Index

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The geomagnetic aa index provides a long climatology of global geomagnetic activity using 2 antipodal observatories at Greenwich and Melbourne- IAGA Bulletin 37,...

  15. Walkability Index

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Walkability Index dataset characterizes every Census 2010 block group in the U.S. based on its relative walkability. Walkability depends upon characteristics of...

  16. Diversity Index

    Data.gov (United States)

    Town of Chapel Hill, North Carolina — This map service summarizes racial and ethnic diversity in the United States in 2012.The Diversity Index shows the likelihood that two persons chosen at random from...

  17. AUTHOR INDEX

    Indian Academy of Sciences (India)

    a granitic terrain of southern India using factor analysis and GIS. 1059. Radhakrishna M see Dev Sheena V .... Landslide susceptibility analysis using Probabilistic. Certainty Factor ... index via entropy-difference analysis. 687. Yidana Sandow ...

  18. Gamma camera

    International Nuclear Information System (INIS)

    Conrad, B.; Heinzelmann, K.G.

    1975-01-01

    A gamma camera is described which obviates the distortion of locating signals generally caused by the varied light conductive capacities of the light conductors in that the flow of light through each light conductor may be varied by means of a shutter. A balancing of the flow of light through each of the individual light conductors, in effect, collective light conductors may be balanced on the basis of their light conductive capacities or properties, so as to preclude a distortion of the locating signals caused by the varied light conductive properties of the light conductors. Each light conductor has associated therewith two, relative to each other, independently adjustable shutters, of which one forms a closure member and the other an adjusting shutter. In this embodiment of the invention it is thus possible to block all of the light conductors leading to a photoelectric transducer, with the exception of those light conductors which are to be balanced. The balancing of the individual light conductors may then be obtained on the basis of the output signals of the photoelectric transducer. (auth)

  19. Intelligent indexing

    International Nuclear Information System (INIS)

    Farkas, J.

    1992-01-01

    In this paper we discuss the relevance of artificial intelligence to the automatic indexing of natural language text. We describe the use of domain-specific semantically-based thesauruses and address the problem of creating adequate knowledge bases for intelligent indexing systems. We also discuss the relevance of the Hilbert space ι 2 to the compact representation of documents and to the definition of the similarity of natural language texts. (author). 17 refs., 2 figs

  20. Intelligent indexing

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, J

    1993-12-31

    In this paper we discuss the relevance of artificial intelligence to the automatic indexing of natural language text. We describe the use of domain-specific semantically-based thesauruses and address the problem of creating adequate knowledge bases for intelligent indexing systems. We also discuss the relevance of the Hilbert space {iota}{sup 2} to the compact representation of documents and to the definition of the similarity of natural language texts. (author). 17 refs., 2 figs.

  1. Check and evaluation system on heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of china based on multi-index comprehensive evaluation method

    International Nuclear Information System (INIS)

    Zhao Jing; Wu Yong; Zhu Neng

    2009-01-01

    Heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China is organized and implemented in a large scale by local government in 15 provinces of North China with the unified guidance and control of central government. Firstly, this paper introduced the target of energy-saving reformation of existing residential buildings in North China and the importance of check and evaluation on this target, then pointed out the necessity of building up an evaluation system for energy-saving retrofit. According to the analytical hierarchy process (AHP), three-grade evaluation system was built up for heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China. Also, based on multi-index comprehensive evaluation method combined with life cycle assessment (LCA) theory, post-evaluation thought and successful degree evaluation method, a mathematical model was established. Finally, a set of scientific method for evaluating heat metering and energy efficiency retrofit of existing residential buildings in northern heating areas of China systematically, scientifically, comprehensively and objectively was created.

  2. Gamma ray generator

    Science.gov (United States)

    Firestone, Richard B; Reijonen, Jani

    2014-05-27

    An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

  3. Neural network consistent empirical physical formula construction for neutron–gamma discrimination in gamma ray tracking

    International Nuclear Information System (INIS)

    Yildiz, Nihat; Akkoyun, Serkan

    2013-01-01

    Highlights: ► Detector responses in neutron–gamma discrimination were estimated by neural networks. ► Novel consistent neural network empirical physical formulas (EPFs) were constructed for detector responses. ► The EPFs are of explicit mathematical functional form. ► The EPFs can be used to derive various physical functions relevant to neutron–gamma discrimination in gamma ray tracking. -- Abstract: Gamma ray tracking is an efficient detection technique in studying exotic nuclei which lies far from beta stability line. To achieve very powerful and extraordinary resolution ability, new detectors based on gamma ray tracking are currently being developed. To reach this achievement, the neutron–gamma discrimination in these detectors is also an important task. In this paper, by suitable layered feedforward neural networks (LFNNs), we have constructed novel and consistent empirical physical formulas (EPFs) for some highly nonlinear detector counts measured in neutron–gamma discrimination. The detector counts data used in the discrimination was actually borrowed from our previous paper. The counts used here had been originally measured versus the following parameters: energy deposited in the first interaction points, difference in the incoming direction of initial gamma rays, and finally figure of merit values of the clusters determined by tracking. The LFNN–EPFs are of explicit mathematical functional form. Therefore, by various suitable operations of mathematical analysis, these LFNN–EPFs can be used to derivate further physical functions which might be potentially relevant to neutron–gamma discrimination performance of gamma ray tracking.

  4. Virginia ESI: INDEX (Index Polygons)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains vector polygons representing the boundaries of all hardcopy cartographic products produced as part of the Environmental Sensitivity Index...

  5. Gamma ray beam transmutation

    International Nuclear Information System (INIS)

    Imasaki, K.; Li, D.; Miyamoto, S.; Amano, S.; Motizuki, T.

    2007-01-01

    We have proposed a new approach to nuclear transmutation by a gamma ray beam of Compton scattered laser photon. We obtained 20 MeV gamma ray in this way to obtain transmutation rates with the giant resonance of 1 97Au and 1 29Iodine. The rate of the transmutation agreed with the theoretical calculation. Experiments on energy spectrum of positron, electron and neutron from targets were performed for the energy balance and design of the system scheme. The reaction rate was about 1.5∼4% for appropriate photon energies and neutron production rate was up to 4% in the measurements. We had stored laser photon more than 5000 times in a small cavity which implied for a significant improvement of system efficiency. Using these technologies, we have designed an actual transmutation system for 1 29Iodine which has a 16 million year's activity. In my presentation, I will address the properties of this scheme, experiments results and transmutation system for iodine transmutation

  6. Isothermal deformation of gamma titanium aluminide

    International Nuclear Information System (INIS)

    Srinivasan, R.; Singh, J.P.; Tuval, E.; Weiss, I.

    1996-01-01

    Gamma titanium aluminide has received considerable attention in recent years from the automotive industry as a potential material for making rotating and reciprocating components to produce a quieter and more efficient engine. The objectives of this study were to identify processing routes for the manufacture of automobile valves from gamma titanium aluminide. The issues considered were microstructure and composition of the material, and processing parameters such as deformation rates, temperatures, and total deformation. This paper examines isothermal deformation of gamma titanium aluminide in order to develop a processing window for this type of material

  7. Indexing mechanisms

    International Nuclear Information System (INIS)

    Wood, A.G.; Parker, G.E.; Berry, R.

    1976-01-01

    It is stated that the indexing mechanism described can be used in a nuclear reactor fuel element inspection rig. It comprises a tubular body adapted to house a canister containing a number of fuel elements located longtitudinally, and has two chucks spaced apart for displacing the fuel elements longitudinally in a stepwise manner, together with a plunger mechanism for displacing them successively into the chucks. A measuring unit is located between the chucks for measuring the diameter of the fuel elements at intervals about their circumferences, and a secondary indexing mechanism is provided for rotating the measuring unit in a stepwise manner. (U.K.)

  8. Gamma spectroscopy of the isotope 253No

    International Nuclear Information System (INIS)

    Kalaninova, Z.

    2009-01-01

    The first part deals with the evaluation of the relative and absolute efficiency of detectors for the registration of gamma radiation to separator SHIP at GSI Darmstadt (Germany). In the second part we discussed the decay alpha-gamma coincidence spectroscopy of isotope 253 No. In conclusion, the basic characteristics of deexcitation of K-isomeric state in isotope 253 No are evaluated. Only sort abstract is published.

  9. Solid state scintillators for gamma spectrometry

    International Nuclear Information System (INIS)

    La Mela, G.; Torrisi, M.

    1991-01-01

    Using different scintillator crystals, measurements of energy resolution and detection efficiency have been performed to detect gamma rays of energy ranging between 500 en 1550 KeV. This investigation is devoted to characterize the best systems to detect photons coming from positron annihilation processes, such as a PET apparatus where the medical image is the final aim of the investigation, and gamma emission from radioisotopes of biomedical interest

  10. Track finding in gamma conversions in CMS

    CERN Document Server

    INSPIRE-00104750

    2008-01-01

    A track finding algorithm has been developed for reconstruction of e+e- pairs. It combines the information of the electromagnetic calorimeter with the information provided by the Tracker. Results on reconstruction efficiency of converted photons, as well as on fake rate are shown for single isolated photons and for photons from H->gamma gamma events with pile-up events at 10^33 cm^-2 s^-1 LHC luminosity.

  11. Thermal neutron capture gamma-rays

    International Nuclear Information System (INIS)

    Tuli, J.K.

    1983-01-01

    The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,α), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,#betta#) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide

  12. Comparative studies on PADC polymeric detector treated by gamma radiation and Ar ion beam

    International Nuclear Information System (INIS)

    El-Saftawy, A.A.; Abdel Reheem, A.M.; Kandil, S.A.; Abd El Aal, S.A.; Salama, S.

    2016-01-01

    Highlights: • The induced defects on PADC polymer by low energy Ar ions bombardments have been investigated and evaluated with respect to gamma rays. • Low energy ions in the range of 3 keV is not examined elsewhere. And offers a competitive irradiation tool to gamma. • The structure, hardness and wear resistance enhanced after irradiation. • The optical properties changed, the optical band gap decreased and the refractive index enhanced. • The used ion source proves efficiency in improving surface properties of PADC polymer in comparison to the obtained results by the powerful energy source, gamma rays. - Abstract: In the present study, a comparative analysis and evaluation of the induced defects in polyallyl diglycol carbonate (PADC) polymeric detector exposed to Ar+ and gamma radiation were made. To get insight into the structure defects due to irradiation, X-ray diffraction (XRD) technique was employed. The PADC surface structure changed after irradiation due to the reduction in the surface crystalline structure and the formation of disordered systems. Also, surface morphology changes were traced using scanning electron microscopy (SEM) and showed minor surface irregularities after gamma irradiation and large changes upon Ar+ irradiation. Additionally, micro-hardness and friction coefficient of the irradiated samples were investigated and found to increase after irradiation. UV–vis spectroscopy was used to estimate the optical band gap energy which considered as the basis for calculating the number of conjugated carbon atoms responsible for the blackening effect and color changes took place over the PADC surface. It was found that as the applied dose increased, the band gap decreased and the number of carbon clusters get larger. The refractive index and the dispersion parameters for the studied polymer were calculated and discussed. Also, the induced defects on the polymer surface which serve as a non-radiative centers resulting in reduced

  13. Comparative studies on PADC polymeric detector treated by gamma radiation and Ar ion beam

    Energy Technology Data Exchange (ETDEWEB)

    El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Abdel Reheem, A.M. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Kandil, S.A. [Cyclotron project, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Abd El Aal, S.A. [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Salama, S. [Radiation Protection & Civil Defense Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt)

    2016-05-15

    Highlights: • The induced defects on PADC polymer by low energy Ar ions bombardments have been investigated and evaluated with respect to gamma rays. • Low energy ions in the range of 3 keV is not examined elsewhere. And offers a competitive irradiation tool to gamma. • The structure, hardness and wear resistance enhanced after irradiation. • The optical properties changed, the optical band gap decreased and the refractive index enhanced. • The used ion source proves efficiency in improving surface properties of PADC polymer in comparison to the obtained results by the powerful energy source, gamma rays. - Abstract: In the present study, a comparative analysis and evaluation of the induced defects in polyallyl diglycol carbonate (PADC) polymeric detector exposed to Ar+ and gamma radiation were made. To get insight into the structure defects due to irradiation, X-ray diffraction (XRD) technique was employed. The PADC surface structure changed after irradiation due to the reduction in the surface crystalline structure and the formation of disordered systems. Also, surface morphology changes were traced using scanning electron microscopy (SEM) and showed minor surface irregularities after gamma irradiation and large changes upon Ar+ irradiation. Additionally, micro-hardness and friction coefficient of the irradiated samples were investigated and found to increase after irradiation. UV–vis spectroscopy was used to estimate the optical band gap energy which considered as the basis for calculating the number of conjugated carbon atoms responsible for the blackening effect and color changes took place over the PADC surface. It was found that as the applied dose increased, the band gap decreased and the number of carbon clusters get larger. The refractive index and the dispersion parameters for the studied polymer were calculated and discussed. Also, the induced defects on the polymer surface which serve as a non-radiative centers resulting in reduced

  14. KWIC Index to Government Publications

    Directory of Open Access Journals (Sweden)

    Margaret Norden

    2013-05-01

    Full Text Available United States and United Nations publications were not efficiently proc- essed nor readily available to the reader at Brandeis University Library. Data processing equipment was used to make a list of this material which could be referred to by a computer produced KWIC index. Currency and availability to the user, and time and cost efficiencies for the library were given precedence over detailed subject access. United States and United Nations classification schemes> and existing bibliographies and indexes were used extensively.

  15. Automatic processing of gamma ray spectra employing classical and modified Fourier transform approach

    International Nuclear Information System (INIS)

    Rattan, S.S.; Madan, V.K.

    1994-01-01

    This report describes methods for automatic processing of gamma ray spectra acquired with HPGe detectors. The processing incorporated both classical and signal processing approach. The classical method was used for smoothing, detecting significant peaks, finding peak envelope limits and a proposed method of finding peak limits, peak significance index, full width at half maximum, detecting doublets for further analysis. To facilitate application of signal processing to nuclear spectra, Madan et al. gave a new classification of signals and identified nuclear spectra as Type II signals, mathematically formalized modified Fourier transform and pioneered its application to process doublet envelopes acquired with modern spectrometers. It was extended to facilitate routine analysis of the spectra. A facility for energy and efficiency calibration was also included. The results obtained by analyzing observed gamma-ray spectra using the above approach compared favourably with those obtained with SAMPO and also those derived from table of radioisotopes. (author). 15 refs., 3 figs., 3 tabs

  16. Effect of gamma irradiation with or without hot water dip and transportation from Thailand to Canada on nutritional qualities, ripening index and sensorial characteristics of Thai mangoes (Nahng Glahng Wahn variety)

    International Nuclear Information System (INIS)

    Lacroix, M.; Gagnon, M.; Pringsulaka, V.

    1993-01-01

    Mangoes of the Nahng Glahng Wahn variety from Thailand were irradiated at the Thai Irradiation Center (TIC) at 0.49 to 0.77 kGy. One batch was retained in Thailand while the other was shipped to the Canadian Irradiation Center (CIC) for investigation of the same variables during storage, to compare the effects of gamma radiation with hot water dip (HWI) or without (I) before and after transportation on the ripening, vitamin C and vitamin A content and sensory qualities of mangoes. The results indicate that the I and HWI treatments delayed the ripening of the mangoes. The irradiated groups appeared to have a slightly higher content of ascorbic acid on the first day after irradiation than their corresponding controls. The sensory evaluation indicates that the panelists mostly favoured the I and HWI irradiated groups for the overall appearance and texture of whole mangoes and pulp and in taste and palatability of the pulp alone. Transportation stress did not appear to have much effect on the ascorbic acid and dehydroascorbic acid levels and the sensorial tests. The mangoes stored and studied in Canada appeared to have a lower vitamin A content. (author)

  17. Possible galactic origin of. gamma. -ray bursts

    Energy Technology Data Exchange (ETDEWEB)

    Manchanda, R K; Ramsden, D [Southampton Univ. (UK). Dept. of Physics

    1977-03-31

    It is stated that extragalactic models for the origin of non-solar ..gamma..-ray bursts include supernova bursts in remote galaxies, and the collapse of the cores of active stars, whilst galactic models are based on flare stars, thermonuclear explosions in neutron stars and the sudden accretion of cometary gas on to neutron stars. The acceptability of any of these models may be tested by the observed size spectrum of the ..gamma..-ray bursts. The extragalactic models predict a power law spectrum with number index -1.5, whilst for the galactic models the number index will be -1. Experimental data on ..gamma..-ray bursts is, however, still meagre, and so far only 44 confirmed events have been recorded by satellite-borne instruments. The number spectrum of the observed ..gamma..-ray bursts indicates that the observed distribution for events with an energy < 10/sup -4/ erg/cm/sup 2/ is flat; this makes the choice of any model completely arbitrary. An analysis of the observed ..gamma..-ray events is here presented that suggests very interesting possibilities for their origin. There appears to be a preferred mean energy for ..gamma..-ray bursts; some 90% of the recorded events show a mean energy between 5 x 10/sup -5/ and 5 x 10/sup -4/ erg/cm/sup 2/, contrary to the predicted characteristics of the number spectrum of various models. A remarkable similarity is found between the distribution of ..gamma..-ray bursts and that of supernova remnants, suggesting a genetic relationship between the two and the galactic origin of the ..gamma..-ray bursts, and the burst source could be identified with completely run down neutron stars, formed during supernova explosions.

  18. Author Index

    Indian Academy of Sciences (India)

    user1

    Astr. (2012) 33, 419–420. Author Index. 419. AGGARWAL SUNNY. Photoionization Cross-Section of Chlorine-like Iron, 291. AMBASTHA ASHOK see Das, A. C., 1. ARAKIDA HIDEYOSHI. Effect of Inhomogeneity of the Universe on a Gravitationally. Bound Local System: A No-Go Result for Explaining the Secular Increase in.

  19. AUTHOR INDEX

    Indian Academy of Sciences (India)

    automorphic solutions to fractional order abstract integro-differential equations. 323. Afrouzi G A see Ala Samira ... 521. Agarwal Praveen. Certain fractional integral operators and the generalized multi-index Mittag- ... of positive solutions for sys- tems of second order multi-point bound- ary value problems on time scales 353.

  20. Analysis of coincidence {gamma}-ray spectra using advanced background elimination, unfolding and fitting algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, M. E-mail: fyzimiro@savba.skfyzimiro@flnr.jinr.ru; Matousek, V. E-mail: matousek@savba.sk; Kliman, J.; Krupa, L.L.; Jandel, M

    2003-04-21

    The efficient algorithms to analyze multiparameter {gamma}-ray spectra are presented. They allow to search for peaks, to separate peaks from background, to improve the resolution and to fit 1-, 2-, 3-parameter {gamma}-ray spectra.

  1. Improving the efficiency of copper indium gallium (Di-)selenide (CIGS) solar cells through integration of a moth-eye textured resist with a refractive index similar to aluminum doped zinc oxide

    Energy Technology Data Exchange (ETDEWEB)

    Burghoorn, M.; Kniknie, B.; Deelen, J. van; Ee, R. van [The Netherlands Organisation for Applied Scientific Research (TNO), De Rondom 1, 5612 AP, Eindhoven (Netherlands); Xu, M. [The Netherlands Organisation for Applied Scientific Research (TNO), De Rondom 1, 5612 AP, Eindhoven (Netherlands); Delft University of Technology, Optics Group, Van der Waalsweg 8, 2628 CH, Delft (Netherlands); Vroon, Z. [The Netherlands Organisation for Applied Scientific Research (TNO), De Rondom 1, 5612 AP, Eindhoven (Netherlands); Zuyd Hogeschool, Nieuw Eyckholt 300, 6419 DJ, Heerlen (Netherlands); Belt, R. van de [Kriya Materials BV, Urmonderbaan 22, 6167 RD, Geleen (Netherlands); Buskens, P., E-mail: pascal.buskens@tno.nl, E-mail: buskens@dwi.rwth-aachen.de [The Netherlands Organisation for Applied Scientific Research (TNO), De Rondom 1, 5612 AP, Eindhoven (Netherlands); DWI – Leibniz Institute for Interactive Materials, Forckenbeckstrasse 50, 52056, Aachen (Germany)

    2014-12-15

    Textured transparent conductors are widely used in thin-film silicon solar cells. They lower the reflectivity at interfaces between different layers in the cell and/or cause an increase in the path length of photons in the Si absorber layer, which both result in an increase in the number of absorbed photons and, consequently, an increase in short-circuit current density (J{sub sc}) and cell efficiency. Through optical simulations, we recently obtained strong indications that texturing of the transparent conductor in copper indium gallium (di-)selenide (CIGS) solar cells is also optically advantageous. Here, we experimentally demonstrate that the J{sub sc} and efficiency of CIGS solar cells with an absorber layer thickness (d{sub CIGS}) of 0.85 μm, 1.00 μm and 2.00 μm increase through application of a moth-eye textured resist with a refractive index that is sufficiently similar to AZO (n{sub resist} = 1.792 vs. n{sub AZO} = 1.913 at 633 nm) to avoid large optical losses at the resist-AZO interface. On average, J{sub sc} increases by 7.2%, which matches the average reduction in reflection of 7.0%. The average relative increase in efficiency is slightly lower (6.0%). No trend towards a larger relative increase in J{sub sc} with decreasing d{sub CIGS} was observed. Ergo, the increase in J{sub sc} can be fully explained by the reduction in reflection, and we did not observe any increase in J{sub sc} based on an increased photon path length.

  2. Improving the efficiency of copper indium gallium (Di-selenide (CIGS solar cells through integration of a moth-eye textured resist with a refractive index similar to aluminum doped zinc oxide

    Directory of Open Access Journals (Sweden)

    M. Burghoorn

    2014-12-01

    Full Text Available Textured transparent conductors are widely used in thin-film silicon solar cells. They lower the reflectivity at interfaces between different layers in the cell and/or cause an increase in the path length of photons in the Si absorber layer, which both result in an increase in the number of absorbed photons and, consequently, an increase in short-circuit current density (Jsc and cell efficiency. Through optical simulations, we recently obtained strong indications that texturing of the transparent conductor in copper indium gallium (di-selenide (CIGS solar cells is also optically advantageous. Here, we experimentally demonstrate that the Jsc and efficiency of CIGS solar cells with an absorber layer thickness (dCIGS of 0.85 μm, 1.00 μm and 2.00 μm increase through application of a moth-eye textured resist with a refractive index that is sufficiently similar to AZO (nresist = 1.792 vs. nAZO = 1.913 at 633 nm to avoid large optical losses at the resist-AZO interface. On average, Jsc increases by 7.2%, which matches the average reduction in reflection of 7.0%. The average relative increase in efficiency is slightly lower (6.0%. No trend towards a larger relative increase in Jsc with decreasing dCIGS was observed. Ergo, the increase in Jsc can be fully explained by the reduction in reflection, and we did not observe any increase in Jsc based on an increased photon path length.

  3. Cosmic gamma bursts

    International Nuclear Information System (INIS)

    Ehstulin, I.V.

    1980-01-01

    A brief consideration is being given to the history of cosmic gamma burst discovery and modern knowledge of their properties. The time dependence of gamma bursts is described and their possible sources are discussed

  4. Efficient genre-specific semantic video indexing

    NARCIS (Netherlands)

    Wu, J.; Worring, M.

    2012-01-01

    Large video collections such as YouTube contain many different video genres, while in many applications the user might be interested in one or two specific video genres only. Thus, when users are querying the system with a specific semantic concept like AnchorPerson, and MovieStars, they are likely

  5. Indexing for summary queries

    DEFF Research Database (Denmark)

    Yi, Ke; Wang, Lu; Wei, Zhewei

    2014-01-01

    ), of a particular attribute of these records. Aggregation queries are especially useful in business intelligence and data analysis applications where users are interested not in the actual records, but some statistics of them. They can also be executed much more efficiently than reporting queries, by embedding...... returned by reporting queries. In this article, we design indexing techniques that allow for extracting a statistical summary of all the records in the query. The summaries we support include frequent items, quantiles, and various sketches, all of which are of central importance in massive data analysis....... Our indexes require linear space and extract a summary with the optimal or near-optimal query cost. We illustrate the efficiency and usefulness of our designs through extensive experiments and a system demonstration....

  6. Afghanistan Index

    DEFF Research Database (Denmark)

    Linnet, Poul Martin

    2007-01-01

    basis. The data are divided into different indicators such as security, polls, drug, social, economic, refugees etc. This represents a practical division and does not indicate that a picture as to for instance security can be obtained by solely looking at the data under security. In order to obtain...... a more valid picture on security this must incorporate an integrated look on all data meaning that for instance the economic data provides an element as to the whole picture of security.......The Afghanistan index is a compilation of quantitative and qualitative data on the reconstruction and security effort in Afghanistan. The index aims at providing data for benchmarking of the international performance and thus provides the reader with a quick possibility to retrieve valid...

  7. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Broomhead, Laurent.

    1980-01-01

    The nuclear gamma astronomy is presented, in particular the Gamma Ray Observatory, an enormous eight tonnes machine fitted with gamma telescopes, scheduled for launching around 1985. It is thereby hoped to study the natural nuclear reactions which occur when stars explode [fr

  8. Gamma Spectroscopy with Pixellated CdZnTe Gamma Detectors

    International Nuclear Information System (INIS)

    Shor, A.; Mardor, I.; Eisen, Y.

    2002-01-01

    Pixellated CdZnTe detectors are good candidates for room temperature gamma detection requiring spectroscopic performance with imaging capabilities. The CdZnTe materials possess high resistivity and good electron charge transport properties. The poor charge transport for the holes inherent in the CdZnTe material can be circumvented by fabricating the electrodes in any one of a number of structures designed for unipolar charge detection[1]. Recent interest in efficient gamma detection at relatively higher gamma energies has imposed more stringent demands on the CdZnTe material and on detector design and optimization. We developed at Soreq a technique where signals from all pixels and from the common electrode are processed, and then a correction is applied for improving the energy resolution and the photopeak efficiency. For illumination with an un-collimated 133 Ba source , we obtain a combined detector energy resolution of 5.0 % FWHM for the 81 keV peak, and 1.5 % FWHM for the 356 keV peak. We discuss the importance of detector material with high electron (μτ) e for thick Pixellated detectors

  9. Contribution to gamma ray transport calculation in heterogeneous media

    International Nuclear Information System (INIS)

    Bourdet, L.

    1985-04-01

    This thesis presents the development of gamma transport calculation codes in three dimension heterogeneous geometries. These codes allow us to define the protection against gamma-rays or verify their efficiency. The laws that govern the interactions of gamma-rays with matters are briefly revised. A library with the all necessary constants for these codes is created. TRIPOLI-2, a code that treats in exact way the neutron transport in matters using Monte-Carlo method, has been adapted to deal with the transport of gamma-rays in matters as well. TRINISHI, a code which considers only one collision, has been realized to treat heterogeneous geometries containing voids. Elaborating a formula that calculates the albedo for gamma-ray reflection (the code ALBANE) allows us to solve the problem of gamma-ray reflection on plane surfaces. NARCISSE-2 deals with gamma-rays that suffer only one reflection on the inner walls of any closed volume (rooms, halls...) [fr

  10. Realization of a gamma multiplicity filter and gamma multiplicity measurements

    International Nuclear Information System (INIS)

    Azgui, F.

    1981-12-01

    A gamma multiplicity filter for the study of reaction mechanism has been realised. It's composed of six NaI(Tl) counters. The flexibility of the geometry allows many configurations. This set up has been tested with gamma radioactive sources and with the 252 Cf source to resolve problems of gamma-efficiency of the NaI(Tl) counters and the contamination of neutrons in these detectors. A logical electronic unit (Encodeur) has been constructed and the around electronic has been developped. This gamma multiplicity filter has been coupled with a detector of high resolution Ge(Li), and used in two reactions: 12 C + 55 Mn at E( 12 C) = 54 MeV; α + 63 Cu at E(α) = 52 MeV. The dominant process is the fusion-evaporation. The compound nucleus 67 Ga, is formed at the same excitation energy. The values of multiplicities Msub(γ) have been extracted using a program based on the formalism of W.J. Ockels. The fractionalization of the angular momentum is well observed for some residual nuclei ( 63 Zn, 64 Zn, 65 Zn), and for each residual nucleus, the average gamma multiplicity is lower with projectile α than that with projectile 12 C. For the most strongly output channel p2n, an entry point for the 64 Zn has been determined in the reactions. All these observations are in good agreement with those published, in the same region (f-p shell) of nuclei. This set up can be coupled with different central detector as, ''X'', neutrons charged particles detectors, and will be used with the new machine SARA to make a systematic study of transfer of angular momentum to the fragments at 30 MeV/A [fr

  11. Reactor gamma spectrometry: status

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1979-01-01

    Current work is described for Compton Recoil Gamma-Ray Spectrometry including developments in experimental technique as well as recent reactor spectrometry measurements. The current status of the method is described concerning gamma spectromoetry probe design and response characteristics. Emphasis is given to gamma spectrometry work in US LWR and BR programs. Gamma spectrometry in BR environments are outlined by focussing on start-up plans for the Fast Test Reactor (FTR). Gamma spectrometry results are presented for a LWR pressure vessel mockup in the Poolside Critical Assembly (PCA) at Oak Ridge National Laboratory

  12. Plutonium characterisation with prompt high energy gamma-rays from (n,gamma) reactions for nuclear warhead dismantlement verification

    Energy Technology Data Exchange (ETDEWEB)

    Postelt, Frederik; Gerald, Kirchner [Carl Friedrich von Weizsaecker-Centre for Science and Peace Research, Hamburg (Germany)

    2015-07-01

    Measurements of neutron induced gammas allow the characterisation of fissile material (i.e. plutonium and uranium), despite self- and additional shielding. Most prompt gamma-rays from radiative neutron capture reactions in fissile material have energies between 3 and 6.5 MeV. Such high energy photons have a high penetrability and therefore minimise shielding and self-absorption effects. They are also isotope specific and therefore well suited to determine the isotopic composition of fissile material. As they are non-destructive, their application in dismantlement verification is desirable. Disadvantages are low detector efficiencies at high gamma energies, as well as a high background of gammas which result from induced fission reactions in the fissile material, as well as delayed gammas from both, (n,f) and(n,gamma) reactions. In this talk, simulations of (n,gamma) measurements and their implications are presented. Their potential for characterising fissile material is assessed and open questions are addressed.

  13. Low level GAMMA0 spectrometry by beta-gamma coincidence

    International Nuclear Information System (INIS)

    Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    1999-01-01

    Low level gamma spectrometry has a wide application, especially in environmental monitoring. Two variants, based on a beta-gamma coincidence technique, were studied. The equipment was composed of a beta detector and a Ge(Li) gamma detector (6% - relative efficiency), with the associated electronics. The gamma rays are recorded by the multichannel analyzer (4096 channels) only if the associated beta particles, which precede the gamma transitions, are registered in coincidence. Two types of beta detectors were used: plastic and liquid scintillators. In both cases, an external lead shield of 5 cm thick was used. The integral gamma background (50-1700 KeV) was reduced about 85 and 50 times, respectively. The corresponding MDA (Minimum Detectable Activity) values decreased about 1.5 and (3-7) times, respectively. The 2π sr plastic beta detector was placed on top the Ge(Li). The sample was inserted between the two detectors. The measurement time was 10 4 s. A 4π sr detector, built of the same material, was also studied, but it proved to be less advantageous because the background was reduced only 16 times; for a MDA reduction similar with that of the 2π sr variant, a longer measurement was needed (3.10 4 s). The other type of beta detector used, was a liquid scintillator. The dissolving of the samples in scintillator ensures a 4π sr measurement geometry. The vials with scintillator (10 ml volume) were placed on top the Ge(Li) and visualised by the photocathode of a phototube. This setup was surrounded by an enclosure which prevent the light penetration. The measurement time was 10 4 s. The only difficulty encountered in this low level measurement method is the accurate determination of the beta efficiency. A limitation is the possibility to measure only small mass samples. These variants are more simple and cheaper than others, previously studied. The advantage of the method is obvious when, instead of low MDA values, shorter measurement times are preferred. The

  14. Prompt Gamma Ray Spectroscopy for process monitoring

    International Nuclear Information System (INIS)

    Zoller, W.H.; Holmes, J.L.

    1991-01-01

    Prompt Gamma Ray Spectroscopy (PGRS) is a very powerful analytical technique able to measure many metallic, contamination problem elements. The technique involves measurement of gamma rays that are emitted by nuclei upon capturing a neutron. This method is sensitive not only to the target element but also to the particular isotope of that element. PGRS is capable of measuring dissolved metal ions in a flowing system. In the field, isotopic neutron sources are used to produce the desired neutron flux ( 252 Cf can produce neutron flux of the order of 10 8 neutrons/cm 2 --sec.). Due to high penetrating power of gamma radiation, high efficiency gamma ray detectors can be placed in an appropriate geometry to maximize sensitivity, providing real-time monitoring with low detection level capabilities

  15. High resolution gamma spectroscopy well logging system

    International Nuclear Information System (INIS)

    Giles, J.R.; Dooley, K.J.

    1997-01-01

    A Gamma Spectroscopy Logging System (GSLS) has been developed to study sub-surface radionuclide contamination. The absolute counting efficiencies of the GSLS detectors were determined using cylindrical reference sources. More complex borehole geometries were modeled using commercially available shielding software and correction factors were developed based on relative gamma-ray fluence rates. Examination of varying porosity and moisture content showed that as porosity increases, and as the formation saturation ratio decreases, relative gamma-ray fluence rates increase linearly for all energies. Correction factors for iron and water cylindrical shields were found to agree well with correction factors determined during previous studies allowing for the development of correction factors for type-304 stainless steel and low-carbon steel casings. Regression analyses of correction factor data produced equations for determining correction factors applicable to spectral gamma-ray well logs acquired under non-standard borehole conditions

  16. Coincidence summing corrections for positron emitters in germanium gamma spectrometry

    International Nuclear Information System (INIS)

    Richardson, A.E.; Sallee, W.W.; New Mexico State Univ., Las Cruces

    1990-01-01

    For positron emitters, 511 keV annihilation quanta are in coincidence with other gamma rays in the decay scheme. If the positrons are not localized at the point of decay, annihilation quanta will be produced at a site some distance from the point of emission. The magnitude of the summing coincidence effect will depend upon the position of annihilation. A method for determining the magnitude of the summing effect for a single gamma of energy E in coincidence with the annihilation gammas from non-localized positrons has been developed which makes use of the counting data for the full energy peaks for both the gamma ray (E) and the 511 keV annihilation gammas. With this data and efficiency calibration data one can determine the average total efficiency for the annihilation positions from which 511 keV gammas originate, and thereby obtain the summing correction factor, SCF, for gamma ray (E). Application of the method to a 22 Na NIST standard gave excellent agreement of observed emission rates for the 1275 keV gamma with the NIST value for wide ranging degrees of positron localization having summing correction factors ranging from 1.021 to 1.505. The method was also applied successfully to 58 Co in neutron-irradiated nickel foils. The method shows promise as a check on the accuracy of the efficiency calibration for a particular detector geometry at the 511 keV energy and energies for other gammas associated with positron emission. (orig.)

  17. Parallel screening of drug-like natural compounds using Caco-2 cell permeability QSAR model with applicability domain, lipophilic ligand efficiency index and shape property: A case study of HIV-1 reverse transcriptase inhibitors

    Science.gov (United States)

    Patel, Rikin D.; Kumar, Sivakumar Prasanth; Patel, Chirag N.; Shankar, Shetty Shilpa; Pandya, Himanshu A.; Solanki, Hitesh A.

    2017-10-01

    The traditional drug design strategy centrally focuses on optimizing binding affinity with the receptor target and evaluates pharmacokinetic properties at a later stage which causes high rate of attrition in clinical trials. Alternatively, parallel screening allows evaluation of these properties and affinity simultaneously. In a case study to identify leads from natural compounds with experimental HIV-1 reverse transcriptase (RT) inhibition, we integrated various computational approaches including Caco-2 cell permeability QSAR model with applicability domain (AD) to recognize drug-like natural compounds, molecular docking to study HIV-1 RT interactions and shape similarity analysis with known crystal inhibitors having characteristic butterfly-like model. Further, the lipophilic properties of the compounds refined from the process with best scores were examined using lipophilic ligand efficiency (LLE) index. Seven natural compound hits viz. baicalien, (+)-calanolide A, mniopetal F, fagaronine chloride, 3,5,8-trihydroxy-4-quinolone methyl ether derivative, nitidine chloride and palmatine, were prioritized based on LLE score which demonstrated Caco-2 well absorption labeling, encompassment in AD structural coverage, better receptor affinity, shape adaptation and permissible AlogP value. We showed that this integrative approach is successful in lead exploration of natural compounds targeted against HIV-1 RT enzyme.

  18. Solid state scintillators for gamma spectrometry. Studio di scintillatori a stato solido per spettrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    La Mela, G; Torrisi, M [Istituto Nazionale di Fisica Nucleare, Catania (Italy)

    1991-01-01

    Using different scintillator crystals, measurements of energy resolution and detection efficiency have been performed to detect gamma rays of energy ranging between 500 en 1550 KeV. This investigation is devoted to characterize the best systems to detect photons coming from positron annihilation processes, such as a PET apparatus where the medical image is the final aim of the investigation, and gamma emission from radioisotopes of biomedical interest.

  19. Study of the gamma radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1949-12-01

    A Geiger counter study has been made of the ..gamma.. radiation of ionium. Eleven quanta of the L radiation of radium were observed for every hundred ..cap alpha.. disintegrations, and three ..gamma.. rays were found with energies of 68, 140, and 240 keV at a rate of 0.85, 0.33, 0.05 quanta, respectively, for 100 disintegrations. It is noted that the radiation spectrum of ionium as a whole is difficult to interpret. In the course of this work, the author calculated the efficiency of a thin-walled aluminum counter, both for the L radiation of radium and for ..gamma.. rays of 68 keV. The author also measured, for soft radiation, the ratio between the efficiency of a thin-walled aluminum counter and that of a similar counter lined with 0.11 mm of lead.

  20. Gamma Splines and Wavelets

    Directory of Open Access Journals (Sweden)

    Hannu Olkkonen

    2013-01-01

    Full Text Available In this work we introduce a new family of splines termed as gamma splines for continuous signal approximation and multiresolution analysis. The gamma splines are born by -times convolution of the exponential by itself. We study the properties of the discrete gamma splines in signal interpolation and approximation. We prove that the gamma splines obey the two-scale equation based on the polyphase decomposition. to introduce the shift invariant gamma spline wavelet transform for tree structured subscale analysis of asymmetric signal waveforms and for systems with asymmetric impulse response. Especially we consider the applications in biomedical signal analysis (EEG, ECG, and EMG. Finally, we discuss the suitability of the gamma spline signal processing in embedded VLSI environment.

  1. Discovery of Pulsations from the Pulsar J0205 6449 in SNR 3C 58 with the Fermi Gamma-Ray Space Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, Aous A.; /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, Marco; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Atwood, William B.; /UC, Santa Cruz; Axelsson, M.; /Stockholm U., OKC /Stockholm U.; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, Guido; /INFN, Trieste /Trieste U.; Bastieri, Denis; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bellazzini, Ronaldo; /INFN, Pisa; Berenji, Bijan; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Blandford, Roger D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bloom, Elliott D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bonamente, E.; /INFN, Perugia /Perugia U.; Borgland, Anders W.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bouvier, A.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bregeon, J.; /INFN, Pisa; Brez, A.; /INFN, Pisa; Brigida, M.; /Bari U. /INFN, Bari /Ecole Polytechnique /Washington U., Seattle /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Columbia U. /IASF, Milan /IASF, Milan /DAPNIA, Saclay /INFN, Perugia /Perugia U. /NASA, Goddard /George Mason U. /Naval Research Lab, Wash., D.C. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /LPCE, Orleans /Montpellier U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /Stockholm U. /Naval Research Lab, Wash., D.C. /INFN, Trieste /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /UC, Santa Cruz /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /CENBG, Gradignan /CENBG, Gradignan /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Manchester U. /Montpellier U. /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; /more authors..

    2011-12-01

    We report the discovery of {gamma}-ray pulsations ({ge}0.1 GeV) from the young radio and X-ray pulsar PSR J0205 + 6449 located in the Galactic supernova remnant 3C 58. Data in the {gamma}-ray band were acquired by the Large Area Telescope aboard the Fermi Gamma-ray Space Telescope (formerly GLAST), while the radio rotational ephemeris used to fold {gamma}-rays was obtained using both the Green Bank Telescope and the Lovell telescope at Jodrell Bank. The light curve consists of two peaks separated by 0.49 {+-} 0.01 {+-} 0.01 cycles which are aligned with the X-ray peaks. The first {gamma}-ray peak trails the radio pulse by 0.08 {+-} 0.01 {+-} 0.01, while its amplitude decreases with increasing energy as for the other {gamma}-ray pulsars. Spectral analysis of the pulsed {gamma}-ray emission suggests a simple power law of index -2.1 {+-} 0.1 {+-} 0.2 with an exponential cutoff at 3.0{sub -0.7}{sup +1.1} {+-} 0.4 GeV. The first uncertainty is statistical and the second is systematic. The integral {gamma}-ray photon flux above 0.1 GeV is (13.7 {+-} 1.4 {+-} 3.0) x 10{sup -8} cm{sup -2} s{sup -1}, which implies for a distance of 3.2 kpc and assuming a broad fan-like beam a luminosity of 8.3 x 10{sup 34} erg s{sup -1} and an efficiency {eta} of 0.3%. Finally, we report a 95% upper limit on the flux of 1.7 x 10{sup -8} cm{sup -2} s{sup -1} for off-pulse emission from the object.

  2. Frontier differences and the global malmquist index

    DEFF Research Database (Denmark)

    Asmild, Mette

    2015-01-01

    This chapter reviews different ways of comparing the efficiency frontiers for subgroups within a data set, specifically program efficiency, the metatechnology (or technology gap) ratio and the global frontier difference index. The latter is subsequently used to define a global Malmquist index...

  3. Development of gamma camera and application to decontamination

    International Nuclear Information System (INIS)

    Yoshida, Akira; Moro, Eiji; Takahashi, Isao

    2013-01-01

    A gamma camera has been developed to support recovering from the contamination caused by the accident of Fukushima Dai-ichi Nuclear Power Plant of Tokyo Electric Power Company. The gamma camera enables recognition of the contamination by visualizing radioactivity. The gamma camera has been utilized for risk communication (explanation to community resident) at local governments in Fukushima. From now on, the gamma camera will be applied to solve decontaminations issues; improving efficiency of decontamination, visualizing the effect of decontamination work and reducing radioactive waste. (author)

  4. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Fichtel, C.E.

    1975-01-01

    The first certain detection of celestial high energy gamma rays came from a satellite experiment flown on the third Orbiting Solar Observatory (OSO-111). A Gamma ray spark chamber telescope with substantively greater sensitivity and angular resolution (a few degrees) flown on the second Small Astronomy Satellite (SAS-II) has now provided a better picture of the gamma ray sky, and particularly the galactic plane and pulsars. This paper will summarize the present picture of gamma ray astronomy as it has developed at this conference from measurements made with experiments carried out on balloons, those remaining on the ground, and ones flown on satellites. (orig.) [de

  5. Gamma sensitivity of pressurized drift tubes

    International Nuclear Information System (INIS)

    Baranov, S.A.; Bojko, I.R.; Shelkov, G.A.; Ignatenko, M.A.

    1995-01-01

    Using a set of commonly used radioactive sources, the efficiency of pressurized drift tubes for gammas with energy from 5.9 keV up to 1.3 MeV has been measured. The tube was made of aluminium and filled with Ar, 15%CO 2 and 2.5%iC 4 H 10 gas mixture at 3 atm. The measured efficiency is compared with the results of the calculations in the frame of our simple model as well as with that of the Monte Carlo simulation using GEANT code. The results of our calculations are in agreement with experimental data, while GEANT simulation tends to give lower efficiency in the energy range of 200 keV γ <1300 keV. The average efficiency of the tube in the field of ATLAS gamma background is about 0.45%. 8 refs., 7 figs., 1 tab

  6. Identification of Water Usage Efficiency for Corn(Zea mays L.Lines Irrigated with Drip Irrigation Under Green House Conditions asPer Plant Water Stress Index Evaluations

    Directory of Open Access Journals (Sweden)

    Ali Beyhan UÇAK

    2017-02-01

    Full Text Available The present study was conducted as a greenhouse study under Çukurova conditions during the years2011-2012. Two different dent corn lines (5A2-B and 22K were used as the plant material of the experiments. Crop water stress index (CWSI values determined through leaf canopy temperature measurements performed ahead of irrigations were used to find outwater use efficiencies. Experiments were conducted in randomized blocks-split plots experimental design with three replications. Drip irrigation was used for irrigations and two different irrigation programs were created as of I100(supplying 100% of depleted water in every seven days and I75(applying 75% of depleted water. The amount of irrigation water applied for in the interaction of I100irrigation and corn lines (5A2-B and22K in the first and second year were respectively varied between 253.0-274.0and between 238.0-261.0mm, seasonal plant water consumptions varied between 294.0-305.0and between 284.6-302.6 mm, kernel yields varied between 2950.0-2990.0 and between 3130.0-3186.0kgha-1. With regard to (in the interaction irrigation treatments xcorn lines, the lowest and the highest CWSI values were observed in the interaction full irrigation (I100 and of the line 22K as 0.22 and in deficit irrigation treatment (I75 of the line 5A2-B as 0.41in the first year; in full irrigation treatment (I100 of the line 22K as 0.20 and in deficit irrigation treatment (I75 of the line 5A2-B as 0.36. The greatest and the lowest chlorophyll contents (in the interaction irrigation treatments x corn lines were respectively observed in I100treatment of the line 22K as 58.3 spad and in I75treatment of the line 5A2-Bas 50.9 spad in the first year; in I100treatment of the line 22K as 59.1 SPAD and in I75treatment of the line 5A2-B as 55.1 spad. While the effects of irrigation treatments on average dry matter contents of the lines were not found to be significant, significant differences were observed in water use efficiency

  7. Control system for gamma camera

    International Nuclear Information System (INIS)

    Miller, D.W.

    1977-01-01

    An improved gamma camera arrangement is described which utilizing a solid state detector, formed of high purity germanium. the central arrangement of the camera operates to effect the carrying out of a trapezoidal filtering operation over antisymmetrically summed spatial signals through gated integration procedures utilizing idealized integrating intervals. By simultaneously carrying out peak energy evaluation of the input signals, a desirable control over pulse pile-up phenomena is achieved. Additionally, through the use of the time derivative of incoming pulse or signal energy information to initially enable the control system, a low level information evaluation is provided serving to enhance the signal processing efficiency of the camera

  8. Deterministic indexing for packed strings

    DEFF Research Database (Denmark)

    Bille, Philip; Gørtz, Inge Li; Skjoldjensen, Frederik Rye

    2017-01-01

    Given a string S of length n, the classic string indexing problem is to preprocess S into a compact data structure that supports efficient subsequent pattern queries. In the deterministic variant the goal is to solve the string indexing problem without any randomization (at preprocessing time...... or query time). In the packed variant the strings are stored with several character in a single word, giving us the opportunity to read multiple characters simultaneously. Our main result is a new string index in the deterministic and packed setting. Given a packed string S of length n over an alphabet σ...

  9. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  10. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  11. Gamma-ray sources

    International Nuclear Information System (INIS)

    Hermsen, W.

    1980-01-01

    Results are presented from an analysis of the celestial gamma-ray fine-scale structure based on over half of the data which may ultimately be available from the COS-B satellite. A catalogue consisting of 25 gamma-ray sources measured at energies above 100 MeV is presented. (Auth.)

  12. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Hillier, R.

    1984-01-01

    The book reviews the development of gamma ray astronomy over the past twenty five years. A large section of the book is devoted to the problems of background radiation and the design of detectors. Gamma rays from the sun, the galactic disc, the galaxy, and extra galactic sources; are also discussed. (U.K.)

  13. Gamma-ray surveys in uranium exploration

    International Nuclear Information System (INIS)

    1979-01-01

    This report is intended to provide newcomers to uranium exploration with an up-to-date statement of the principal factors to be considered in planning and using gamma-ray surveys. Since the report incorporates the results of recent research, and since its preparation was influenced by the cumulative experience of its contributors, it should also be useful to those who already have some knowledge of radioactivity surveys and methods. The intention is that the information and explanations given in the report will make it possible for gamma-ray surveys to be used in the most efficient way for a given exploration task

  14. KWIC Index to Government Publications

    OpenAIRE

    Norden, Margaret

    2013-01-01

    United States and United Nations publications were not efficiently proc- essed nor readily available to the reader at Brandeis University Library. Data processing equipment was used to make a list of this material which could be referred to by a computer produced KWIC index. Currency and availability to the user, and time and cost efficiencies for the library were given precedence over detailed subject access. United States and United Nations classification schemes> and existing bibliograp...

  15. The gamma function

    CERN Document Server

    Artin, Emil

    2015-01-01

    This brief monograph on the gamma function was designed by the author to fill what he perceived as a gap in the literature of mathematics, which often treated the gamma function in a manner he described as both sketchy and overly complicated. Author Emil Artin, one of the twentieth century's leading mathematicians, wrote in his Preface to this book, ""I feel that this monograph will help to show that the gamma function can be thought of as one of the elementary functions, and that all of its basic properties can be established using elementary methods of the calculus."" Generations of teachers

  16. Scientific Journal Indexing

    Directory of Open Access Journals (Sweden)

    Getulio Teixeira Batista

    2007-08-01

    Full Text Available It is quite impressive the visibility of online publishing compared to offline. Lawrence (2001 computed the percentage increase across 1,494 venues containing at least five offline and five online articles. Results shown an average of 336% more citations to online articles compared to offline articles published in the same venue. If articles published in the same venue are of similar quality, then they concluded that online articles are more highly cited because of their easier access. Thomson Scientific, traditionally concerned with printed journals, announced on November 28, 2005, the launch of Web Citation Index™, the multidisciplinary citation index of scholarly content from institutional and subject-based repositories (http://scientific.thomson. com/press/2005/8298416/. The Web Citation Index from the abstracting and indexing (A&I connects together pre-print articles, institutional repositories and open access (OA journals (Chillingworth, 2005. Basically all research funds are government granted funds, tax payer’s supported and therefore, results should be made freely available to the community. Free online availability facilitates access to research findings, maximizes interaction among research groups, and optimizes efforts and research funds efficiency. Therefore, Ambi-Água is committed to provide free access to its articles. An important aspect of Ambi-Água is the publication and management system of this journal. It uses the Electronic System for Journal Publishing (SEER - http://www.ibict.br/secao.php?cat=SEER. This system was translated and customized by the Brazilian Institute for Science and Technology Information (IBICT based on the software developed by the Public Knowledge Project (Open Journal Systems of the British Columbia University (http://pkp.sfu.ca/ojs/. The big advantage of using this system is that it is compatible with the OAI-PMH protocol for metadata harvesting what greatly promotes published articles

  17. Gamma sensitivity of the Eberline PCM-1

    International Nuclear Information System (INIS)

    Blanton, J.D.

    1988-01-01

    This paper reports that normally, alarm setpoints for the Eberline PCM-1 series personnel contamination monitors are calculated based upon efficiencies measured using 100-cm 2 or larger beta or mixed beta-gamma sources. This simulates the type of contamination most frequently encountered on personnel and clothing--low-level, distributed beta-gamma emitters. In most circumstances, the PCM-1's sensitivity to the other type of contamination encountered in nuclear plant work--hot particles--would be expected to be the same as, or better than, its sensitivity to distributed contamination. However, particles that are deposited on skin or clothing can be partially shielded from the view of the PCM-1's detectors. In these situations, the PCm-1's sensitivity to gamma radiation may be more relevant than its sensitivity to betas

  18. On the sum of Gamma-Gamma variates with application to the fast outage probability evaluation over fading channels

    KAUST Repository

    Ben Issaid, Chaouki; Rached, Nadhir B.; Kammoun, Abla; Alouini, Mohamed-Slim; Tempone, Raul

    2017-01-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of independent and identically distributed Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  19. On the sum of Gamma-Gamma variates with application to the fast outage probability evaluation over fading channels

    KAUST Repository

    Ben Issaid, Chaouki

    2017-04-01

    The Gamma-Gamma distribution has recently emerged in a number of applications ranging from modeling scattering and reverbation in sonar and radar systems to modeling atmospheric turbulence in wireless optical channels. In this respect, assessing the outage probability achieved by some diversity techniques over this kind of channels is of major practical importance. In many circumstances, this is intimately related to the difficult question of analyzing the statistics of a sum of Gamma-Gamma random variables. Answering this question is not a simple matter. This is essentially because outage probabilities encountered in practice are often very small, and hence the use of classical Monte Carlo methods is not a reasonable choice. This lies behind the main motivation of the present work. In particular, this paper proposes a new approach to estimate the left tail of the sum of independent and identically distributed Gamma-Gamma variates. More specifically, we propose a mean-shift importance sampling scheme that efficiently evaluates the outage probability of L-branch maximum ratio combining diversity receivers over Gamma-Gamma fading channels. The proposed estimator satisfies the well-known bounded relative error criterion. We show the accuracy and the efficiency of our approach compared to naive Monte Carlo via some selected numerical simulations.

  20. Basics of Gamma Ray Detection

    Energy Technology Data Exchange (ETDEWEB)

    Stinnett, Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Venkataraman, Ram [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-13

    The objective of this training is to explain the origin of x-rays and gamma rays, gamma ray interactions with matter, detectors and electronics used in gamma ray-spectrometry, and features of a gamma-ray spectrum for nuclear material that is safeguarded.

  1. Stirling Engine Cycle Efficiency

    OpenAIRE

    Naddaf, Nasrollah

    2012-01-01

    ABSTRACT This study strives to provide a clear explanation of the Stirling engine and its efficiency using new automation technology and the Lab View software. This heat engine was invented by Stirling, a Scottish in 1918. The engine’s working principles are based on the laws of thermodynamics and ability of volume expansion of ideal gases at different temperatures. Basically there are three types of Stirling engines: the gamma, beta and alpha models. The commissioner of the thesis ...

  2. Gamma histograms for radiotherapy plan evaluation

    International Nuclear Information System (INIS)

    Spezi, Emiliano; Lewis, D. Geraint

    2006-01-01

    Background and purpose: The technique known as the 'γ evaluation method' incorporates pass-fail criteria for both distance-to-agreement and dose difference analysis of 3D dose distributions and provides a numerical index (γ) as a measure of the agreement between two datasets. As the γ evaluation index is being adopted in more centres as part of treatment plan verification procedures for 2D and 3D dose maps, the development of methods capable of encapsulating the information provided by this technique is recommended. Patients and methods: In this work the concept of γ index was extended to create gamma histograms (GH) in order to provide a measure of the agreement between two datasets in two or three dimensions. Gamma area histogram (GAH) and gamma volume histogram (GVH) graphs were produced using one or more 2D γ maps generated for each slice of the irradiated volume. GHs were calculated for IMRT plans, evaluating the 3D dose distribution from a commercial treatment planning system (TPS) compared to a Monte Carlo (MC) calculation used as reference dataset. Results: The extent of local anatomical inhomogenities in the plans under consideration was strongly correlated with the level of difference between reference and evaluated calculations. GHs provided an immediate visual representation of the proportion of the treated volume that fulfilled the γ criterion and offered a concise method for comparative numerical evaluation of dose distributions. Conclusions: We have introduced the concept of GHs and investigated its applications to the evaluation and verification of IMRT plans. The gamma histogram concept set out in this paper can provide a valuable technique for quantitative comparison of dose distributions and could be applied as a tool for the quality assurance of treatment planning systems

  3. FTR europia gamma heating

    International Nuclear Information System (INIS)

    Ward, J.T. Jr.

    1975-01-01

    Calculated and experimental gamma heating rates of europia in the Engineering Mockup Critical Assembly (EMC) were correlated. A calculated to experimental (C/E) ratio of 1.086 was established in validating the theoretical approach and computational technique applied in the calculations. Gamma heat deposition rates in the FTR with Eu 2 O 3 control absorbers were determined from three-dimensional calculations. Maximum gamma heating was found to occur near the tip of a half-inserted row 5 control rod assembly--12.8 watts/gm of europia. Gamma heating profiles were established for a single half-inserted europia absorber assembly. Local heat peaking was found not to alter significantly heating rates computed in the FTR core model, where larger mesh interval sizes precluded examination of spatially-limited heating gradients. These computations provide the basis for thermal-hydraulic analyses to ascertain temperature profiles in the FTR under europia control

  4. Beta and Gamma Gradients

    DEFF Research Database (Denmark)

    Løvborg, Leif; Gaffney, C. F.; Clark, P. A.

    1985-01-01

    Experimental and/or theoretical estimates are presented concerning, (i) attenuation within the sample of beta and gamma radiation from the soil, (ii) the gamma dose within the sample due to its own radioactivity, and (iii) the soil gamma dose in the proximity of boundaries between regions...... of differing radioactivity. It is confirmed that removal of the outer 2 mm of sample is adequate to remove influence from soil beta dose and estimates are made of the error introduced by non-removal. Other evaluations include variation of the soil gamma dose near the ground surface and it appears...... that the present practice of avoiding samples above a depth of 0.3 m may be over-cautious...

  5. Gamma spectrometry today

    International Nuclear Information System (INIS)

    Hemingway, J.

    1990-01-01

    This paper reviews the important advances in gamma spectroscopy made in recent years. Improvements in detectors and other components and the addition of on-line computer control systems is discussed. (UK)

  6. Toward standardising gamma camera quality control procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.A.; Alnaaimi, M.A.; Alduaij, M.A.; Mohamed, M.O.; Ibahim, S.Y.; Alkandari, F.A.; Bradley, D.A.

    2015-01-01

    Attaining high standards of efficiency and reliability in the practice of nuclear medicine requires appropriate quality control (QC) programs. For instance, the regular evaluation and comparison of extrinsic and intrinsic flood-field uniformity enables the quick correction of many gamma camera problems. Whereas QC tests for uniformity are usually performed by exposing the gamma camera crystal to a uniform flux of gamma radiation from a source of known activity, such protocols can vary significantly. Thus, there is a need for optimization and standardization, in part to allow direct comparison between gamma cameras from different vendors. In the present study, intrinsic uniformity was examined as a function of source distance, source activity, source volume and number of counts. The extrinsic uniformity and spatial resolution were also examined. Proper standard QC procedures need to be implemented because of the continual development of nuclear medicine imaging technology and the rapid expansion and increasing complexity of hybrid imaging system data. The present work seeks to promote a set of standard testing procedures to contribute to the delivery of safe and effective nuclear medicine services. - Highlights: • Optimal parameters for quality control of the gamma camera are proposed. • For extrinsic and intrinsic uniformity a minimum of 15,000 counts is recommended. • For intrinsic flood uniformity the activity should not exceed 100 µCi (3.7 MBq). • For intrinsic uniformity the source to detector distance should be at least 60 cm. • The bar phantom measurement must be performed with at least 15 million counts.

  7. Dynamic gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Luan Shuang; Swanson, Nathan; Chen Zhe; Ma Lijun

    2009-01-01

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can obtain a family of plans representing a tradeoff between the delivery time and

  8. Dynamic gamma knife radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Luan Shuang; Swanson, Nathan; Chen Zhe [Department of Computer Science, University of New Mexico, Albuquerque, NM 87131 (United States); Ma Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA 94143 (United States)], E-mail: sluan@cs.unm.edu, E-mail: nate@cs.unm.edu, E-mail: zchen@cs.unm.edu, E-mail: lijunma@radonc.ucsf.edu

    2009-03-21

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can

  9. IMEF gamma scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

  10. IMEF gamma scanning system

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum.

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs

  11. Development of gallium arsenide gamma spectrometric detector

    International Nuclear Information System (INIS)

    Kobayashi, T.; Kuru, I.

    1975-03-01

    measuring gamma-ray spectrum with GaAs detector. However, gamma-ray counting efficiency of the detector was not enough to built portable type instrument of gamma-ray spectrometer used for routine works of nuclear safeguards. In order to improve gamma-ray counting efficiency of the detector, double-epitaxial-layer detector has been studied. The preliminary results showed that the improvement of the detector gamma-ray counting efficiency was possible by using double-epitaxial-layer structure. It was also clarified that the good quality GaAs crystal was a key to obtaining a low noise, good charge collection detector

  12. GammaSem Proceedings - A Nordic seminar for users of gamma spectrometry

    International Nuclear Information System (INIS)

    Nunez, P.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.; Israelson, C.

    2010-03-01

    The project GammaSem was proposed to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and to establish a network of users of gamma spectrometry in the Nordic countries, thereby strengthening the collaboration and improving all participants' competence in practical gamma spectrometry. The seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 75 people participated; representing 34 different universities, commercial companies, research institutes and also all Nordic authorities. During the seminar several key issues for follow-up were identified and working groups for addressing the identified problems were established. The working groups were: 1) Uncertainties and detections of limits 2) True summing coincidence 3) Monte Carlo simulations and efficiency transfer 4) Absorption (density corrections and geometries) 5) Mobile gamma spectrometry systems 6) Nuclear forensics (on special samples and special parts of the spectra). The identified topics will form the basis for the agenda of the next seminar in 2010. There, the different working groups will be invited to present their ideas/solutions to the relevant problems. (author)

  13. Gamma--gamma directional correlations and coincidence studies in /sup 154/Gd

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, J B; Gupta, S L; Hamilton, J H; Ramayya, A V [Vanderbilt Univ., Nashville, Tenn. (USA). Dept. of Physics; Delhi Univ. (India). Ramjas Coll.)

    1977-06-01

    The intensities, placements and E2/M1 mixing ratios of transitions in the decay of /sup 154/Eu have been carefully studied to provide accurate data for microscopic calculations. Coincidence relationships in thhe decay of /sup 154/Eu have been studied extensively with a multiparameter ..gamma..-..gamma.. coincidence system with two large volume Ge(Li) detectors. Spectra in coincidence with twenty energy gates were analyzed. Twenty-nine new coincidence relationships were established and confirmed most, but not all, of several levels previously assigned by energy fits only. From an analysis of coincidence spectra and singles spectra with a 18% efficiency Ge(Li) detector new information on the gamma-ray intensities were obtained. Precise values of the E2/M1 mixing ratios of transitions from the gamma- and beta-vibrational bands to the g.s. band have been determined from ..gamma..-..gamma.. directional correlation measurements with a NaI(Tl)-Ge(Li) detector coincidence system. Mixing ratios were obtained for a number of other transitions including those from KPI = 0/sup -/ and 2+ bands from direct and skipped cascade correlations.

  14. GammaSem Proceedings - A Nordic seminar for users of gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Nunez, P. (ed.) (Institute for Energy Technology (IFE) (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority (STUK) (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark, Risoe National Lab. for Sustainable Energy. Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (IS)); Israelson, C. (National Institute of Radiation Protection (Denmark))

    2010-03-15

    The project GammaSem was proposed to provide a forum for discussions and sharing of information on practical issues concerning gamma spectrometry and to establish a network of users of gamma spectrometry in the Nordic countries, thereby strengthening the collaboration and improving all participants' competence in practical gamma spectrometry. The seminars' focus was practical challenges met by the users themselves, rather than theoretical matters. Scientists and users of gamma spectrometry from all five Nordic countries were invited to the seminar, as well as scientist from the Baltic countries. A total of 75 people participated; representing 34 different universities, commercial companies, research institutes and also all Nordic authorities. During the seminar several key issues for follow-up were identified and working groups for addressing the identified problems were established. The working groups were: 1) Uncertainties and detections of limits 2) True summing coincidence 3) Monte Carlo simulations and efficiency transfer 4) Absorption (density corrections and geometries) 5) Mobile gamma spectrometry systems 6) Nuclear forensics (on special samples and special parts of the spectra). The identified topics will form the basis for the agenda of the next seminar in 2010. There, the different working groups will be invited to present their ideas/solutions to the relevant problems. (author)

  15. Neutron-gamma discrimination of boron loaded plastic scintillator

    International Nuclear Information System (INIS)

    Wang Dong; He Bin; Zhang Quanhu; Wu Chuangxin; Luo Zhonghui

    2010-01-01

    Boron loaded plastic scintillator could detect both fast neutrons thanks to hydrogen and thermal neutrons thanks to 10B. Both reactions have large cross sections, and results in high detection efficiency of incident neutrons. However, similar with other organic scintillators, boron loaded plastic scintillator is sensitive to gamma rays and neutrons. So gamma rays must be rejected from neutrons using their different behavior in the scintillator. In the present research zero crossing method was used to test neutron-gamma discrimination of BC454 boron loaded plastic scintillator. There are three Gaussian peaks in the time spectrum, they are corresponding to gamma rays, fast neutrons and flow neutrons respectively. Conclusion could be made that BC454 could clear discriminate slow neutrons and gamma, but the discrimination performance turns poor as the neutrons' energy becomes larger. (authors)

  16. Proposed computerized cross-index system for storage and retrieval ...

    African Journals Online (AJOL)

    Card index systems are normally not very efficient when used for cross-indexing purposes and information retrieval, useful information frequently being lost because of poor indexing and little or no cross-referencing. Large card index systems are often compiled by research workers but these potentially useful stores of ...

  17. Food irradiation: Gamma processing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kunstadt, P [MDS Nordion International, 447 March Road. Kanata, Ontario, K2K148 (Canada)

    1998-12-31

    The number of products being radiation processed is constantly increasing and today include such diverse items as medical disposable, fruits and vegetables, bulk spices, meats, sea foods and waste effluents. Not only do the products differ but also many products, even those within the same groupings, require different minimum and maximum radiation doses. These variations create many different requirements in the irradiator design. The design of Cobalt-60 radiation processing facilities is well established for a number of commercial applications. Installations in over 40 countries, with some in operation since the early 1960s, are testimony to the fact that irradiator design, manufacture, installation and operation is a well established technology. However, in order to design gamma irradiators for the preservation of foods one must recognize those parameters typical to the food irradiation process as well as those systems and methods already well established in the food industry. This paper discusses the basic design concepts for gamma food irradiators. They are most efficient when designed to handle a limited product density range at an established dose. Safety of Cobalt-60 transport, safe facility operation principles and the effect of various processing parameters on economics, will also be discussed. (Author)

  18. Food irradiation: Gamma processing facilities

    International Nuclear Information System (INIS)

    Kunstadt, P.

    1997-01-01

    The number of products being radiation processed is constantly increasing and today include such diverse items as medical disposable, fruits and vegetables, bulk spices, meats, sea foods and waste effluents. Not only do the products differ but also many products, even those within the same groupings, require different minimum and maximum radiation doses. These variations create many different requirements in the irradiator design. The design of Cobalt-60 radiation processing facilities is well established for a number of commercial applications. Installations in over 40 countries, with some in operation since the early 1960s, are testimony to the fact that irradiator design, manufacture, installation and operation is a well established technology. However, in order to design gamma irradiators for the preservation of foods one must recognize those parameters typical to the food irradiation process as well as those systems and methods already well established in the food industry. This paper discusses the basic design concepts for gamma food irradiators. They are most efficient when designed to handle a limited product density range at an established dose. Safety of Cobalt-60 transport, safe facility operation principles and the effect of various processing parameters on economics, will also be discussed. (Author)

  19. Food irradiation: Gamma processing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kunstadt, P. [MDS Nordion International, 447 March Road. Kanata, Ontario, K2K148 (Canada)

    1997-12-31

    The number of products being radiation processed is constantly increasing and today include such diverse items as medical disposable, fruits and vegetables, bulk spices, meats, sea foods and waste effluents. Not only do the products differ but also many products, even those within the same groupings, require different minimum and maximum radiation doses. These variations create many different requirements in the irradiator design. The design of Cobalt-60 radiation processing facilities is well established for a number of commercial applications. Installations in over 40 countries, with some in operation since the early 1960s, are testimony to the fact that irradiator design, manufacture, installation and operation is a well established technology. However, in order to design gamma irradiators for the preservation of foods one must recognize those parameters typical to the food irradiation process as well as those systems and methods already well established in the food industry. This paper discusses the basic design concepts for gamma food irradiators. They are most efficient when designed to handle a limited product density range at an established dose. Safety of Cobalt-60 transport, safe facility operation principles and the effect of various processing parameters on economics, will also be discussed. (Author)

  20. EJSCREEN Indexes 2015 Public

    Data.gov (United States)

    U.S. Environmental Protection Agency — There is an EJ Index for each environmental indicator. There are eight EJ Indexes in EJSCREEN reflecting the 8 environmental indicators. The EJ Index names are:...

  1. EJSCREEN Indexes 2016 Public

    Data.gov (United States)

    U.S. Environmental Protection Agency — There is an EJ Index for each environmental indicator. There are eleven EJ Indexes in EJSCREEN reflecting the 11 environmental indicators. The EJ Index names are:...

  2. Laser Compton Scattering Gamma Ray Induced Photo-Trasmutation

    CERN Document Server

    Li, Dazhi

    2004-01-01

    High brightness beams of gamma rays produced with laser Compton scattering have the potential to realize photo-transmutation through (γ,n) reaction, implying an efficient method to dispose long-lived fission products. Preliminary investigations have been carried out in understanding the feasibility of development of a transmutation facility to repose nuclear waste. A laser Compton scattering experimental setup based on a storage ring started to generate gamma-ray beams for studying the coupling of gamma photons and nuclear giant resonance. This paper demonstrates the dependency of nuclear transmutation efficiency on target dimensions and gamma ray features. 197Au sample was adopted in our experiment, and experimental results correspond to the theoretical estimations.

  3. Found: A Galaxy's Missing Gamma Rays

    Science.gov (United States)

    Kohler, Susanna

    2016-04-01

    Recent reanalysis of data from the Fermi Gamma-ray Space Telescope has resulted in the first detection of high-energy gamma rays emitted from a nearby galaxy. This discovery reveals more about how supernovae interact with their environments.Colliding Supernova RemnantAfter a stellar explosion, the supernovas ejecta expand, eventually encountering the ambient interstellar medium. According to models, this generates a strong shock, and a fraction of the kinetic energy of the ejecta is transferred into cosmic rays high-energy radiation composed primarily of protons and atomic nuclei. Much is still unknown about this process, however. One open question is: what fraction of the supernovas explosion power goes into accelerating these cosmic rays?In theory, one way to answer this is by looking for gamma rays. In a starburst galaxy, the collision of the supernova-accelerated cosmic rays with the dense interstellar medium is predicted to produce high-energy gamma rays. That radiation should then escape the galaxy and be visible to us.Pass 8 to the RescueObservational tests of this model, however, have beenstumped by Arp 220. This nearby ultraluminous infrared galaxy is the product of a galaxy merger ~700 million years ago that fueled a frenzy of starbirth. Due to its dusty interior and extreme levels of star formation, Arp 220 has long been predicted to emit the gamma rays produced by supernova-accelerated cosmic rays. But though weve looked, gamma-ray emission has never been detected from this galaxy until now.In a recent study, a team of scientists led by Fang-Kun Peng (Nanjing University) reprocessed 7.5 years of Fermi observations using the new Pass 8 analysis software. The resulting increase in resolution revealed the first detection of GeV emission from Arp 220!Acceleration EfficiencyGamma-ray luminosity vs. total infrared luminosity for LAT-detected star-forming galaxies and Seyferts. Arp 220s luminosities are consistent with the scaling relation. [Peng et al. 2016

  4. Automated TLD system for gamma radiation monitoring

    International Nuclear Information System (INIS)

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  5. Fast amplification system for gamma spectroscopy

    International Nuclear Information System (INIS)

    Jesus, E.F.O.; Lopes, R.T.

    1992-01-01

    An amplification system for gamma spectroscopy with high counting rates was developed. The system was constructed with operational amplifiers, and tested and compared with ORTEC conventional system, using Iridium-192 as source of 9,25 x 10 1 0 Bq of activity and NaI (Tl) detector. The constructed system showed a better performance in relation to efficiency and resolution parameters, tested before. (C.G.C.)

  6. Nanodefect formation in LiF crystals under gamma irradiation

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Ibragimova, Eh.M.; Kalanov, M.U.; Muminov, M.I.

    2006-01-01

    One studied the spectra of absorption and of photoluminescence, microhardness and performed X-ray structure analysis of gamma-irradiated LiF crystals in a shutdown reactor and in 60 Co source when gamma-radiation dose rate was equal to 7.65 Gy/s. In addition to formation of point and combined radiation defects one detected the presence of the gamma-irradiation induced 28 nm size nanoparticles of LiOH phase in Li sublattice. Formation of defects is shown to occur more efficiently in a shutdown reactor in contrast to 60 Co source [ru

  7. Archives decontamination by gamma irradiation

    International Nuclear Information System (INIS)

    Bratu, E.; Moise, I.V.; Cutrubinis, M.; Negut, D.C.; Virgolici, Marian

    2009-01-01

    The treatment of archives with gamma irradiation is an efficient and environmental friendly alternative for biological decontamination of large volume of archives. It substitutes the use of chemicals for conservation and contributes to safer workplaces. This work is targeting documents from recent archives where the value of information is not obsolete and may become an important historical and cultural testimony. For a successful treatment, an optimal absorbed dose has to be established. An excessive dose may damage papers and an insufficient one will not reduce bioburden to the desired level. An interdisciplinary team was performing various physical and chemical tests in order to evaluate deterioration of paper at high doses. In the case of natural disaster, it is not excluded the '' emergency '' treatment for documents in immediate danger of total destruction. (authors)

  8. The Portuguese gamma irradiation facility

    International Nuclear Information System (INIS)

    Mendes, C.M.; Almeida, J.C.; Botelho, M.L.; Cavaco, M.C.; Almeida-Vara, E.; Andrade, M.E.

    1990-01-01

    A Gamma Radiation Facility was built up in the National Laboratory of Industrial Technology and Engineering (LNETI), Lisbon, Portugal. This plant (UTR GAMA-Pi) is a Cobalt-60 dry storage continuous facility with a nominal capacity of 1.5 x 10 16 Bq. The initial activity is 1.1 x 10 16 Bq and the throughput capacity 10 3 ton/year for product with a bulk density of 0.2 g/cm 3 treated with a minimum absorbed dose of 25 kGy. Complementary control devices were installed: ventilation system, closed water refrigeration circuit, internal TV system, detection and extinction fire system and emergency power group. It must be emphasized that the best attention was given to the conception and efficiency of the interlock safety systems. This facility will be utilized mainly for radiosterilization of medical articles and decontamination of wine cork stoppers. (author)

  9. Gamma motes for detection of radioactive materials in shipping containers

    International Nuclear Information System (INIS)

    Harold McHugh; William Quam; Stephan Weeks; Brendan Sever

    2007-01-01

    Shipping containers can be effectively monitored for radiological materials using gamma (and neutron) motes in distributed mesh networks. The mote platform is ideal for collecting data for integration into operational management systems required for efficiently and transparently monitoring international trade. Significant reductions in size and power requirements have been achieved for room-temperature cadmium zinc telluride (CZT) gamma detectors. Miniaturization of radio modules and microcontroller units are paving the way for low-power, deeply-embedded, wireless sensor distributed mesh networks

  10. Characteristics of a gamma telescope on the ''Kosmos-561'' satellite

    International Nuclear Information System (INIS)

    Bokov, V.L.; Kruglov, E.M.

    1981-01-01

    The results of calculations of gamma telescope characteristics intended for investigating cosmic γ radiation at E>=100 MeV in the ''Cosmos 561'' artificial Earth satellite, using the Monte Carlo method, are presented. The gamma spectrometer contains a lead converter, scintillation deteectors of polysterene, a unit of spark chambers and a Cherenkov detector of lead glass. The dependence of the device effective area and angular resolution on γ quanta energy is calculated. The relative radiation pattern of the device is given. The given integral characteristics of the gamma telescope for a γ quanta flux with an exponential spectrum are the following: the effective geometrical factor and effective device area depending on the spectrum index. The calibration gamma telescope curve is plotted according to the electron mean free path distribution [ru

  11. Gamma radiation effect study in polycarbonate optical and mechanics properties

    International Nuclear Information System (INIS)

    Araujo, E.S. de.

    1991-02-01

    Polycarbonates (PC) are used in different industrial applications due to their excellent dielectric characteristics, impact resistance, and high temperature resistance. In some of these applications, the polycarbonates are exposed to gamma radiation which produces molecular scissions, causing changes in the polycarbonate properties. To estimate the radiation effects in the Durolon polycarbonate, samples were irradiated with 60 Co gamma rays with doses between 0,2 kGy and 300 kGy. The results obtained showed that the PC mechanical properties are not changed due to the gamma radiation. However the results showed an expressive variation in the yellowness index for doses above 1 kGy. The results showed that it is possible to use the gamma sterilization of PC in applications where the coloration of PC is not critical. (author). 21 refs, 25 figs, 3 tabs

  12. Real time gamma-ray signature identifier

    Science.gov (United States)

    Rowland, Mark [Alamo, CA; Gosnell, Tom B [Moraga, CA; Ham, Cheryl [Livermore, CA; Perkins, Dwight [Livermore, CA; Wong, James [Dublin, CA

    2012-05-15

    A real time gamma-ray signature/source identification method and system using principal components analysis (PCA) for transforming and substantially reducing one or more comprehensive spectral libraries of nuclear materials types and configurations into a corresponding concise representation/signature(s) representing and indexing each individual predetermined spectrum in principal component (PC) space, wherein an unknown gamma-ray signature may be compared against the representative signature to find a match or at least characterize the unknown signature from among all the entries in the library with a single regression or simple projection into the PC space, so as to substantially reduce processing time and computing resources and enable real-time characterization and/or identification.

  13. Gamma irradiation effects in low density polyethylene

    International Nuclear Information System (INIS)

    Ono, Lilian S.; Scagliusi, Sandra R.; Cardoso, Elisabeth E.L.; Lugao, Ademar B.

    2011-01-01

    Low density polyethylene (LDPE) is obtained from ethylene gas polymerization, being one of the most commercialized polymers due to its versatility and low cost. It's a semi-crystalline polymer, usually inactive at room temperature, capable to attain temperatures within a 80 deg C - 100 deg C range, without changing its physical-chemical properties. LDPE has more resistance when compared to its equivalent High Density Polyethylene (HDPE). LDPE most common applications consist in manufacturing of laboratory materials, general containers, pipes, plastic bags, etc. Gamma radiation is used on polymers in order to modify mechanical and physical-chemical features according to utility purposes. This work aims to the study of gamma (γ) radiation interaction with low density polyethylene to evaluate changes in its physical-chemical properties. Polymer samples were exposed to 5, 10, 15, 20 and 30kGy doses, at room temperature. Samples characterization employed Thermal Analysis, Melt Flow Index, Infrared Spectroscopy and Swelling tests. (author)

  14. Study of the effect of the gamma radiation in polycarbonate

    International Nuclear Information System (INIS)

    Khoury, H.J.; Araujo, E.S. de; Silveira, S.V. da

    1990-01-01

    To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with 60 Co gamma beam with doses between 0,2KGy and 50KGy. The results obtained shown variations in the yellowed index above 1KGy dose. Their mechanical proprieties are not changed at interval of this doses. (author) [pt

  15. System for gamma-gamma formation density logging while drilling

    International Nuclear Information System (INIS)

    Paske, W.C.

    1991-01-01

    The patent relates to a system for logging subterranean formations for the determination of formation density by using gamma radiation. Gamma ray source and detection means are disposed within a housing adapted for positioning within a borehole for the emission and detection of gamma rays propagating through earth formations and borehole drilling fluid. The gamma ray detection means comprises first and second gamma radiation sensors geometrically disposed within the housing, the same longitudinal distance from the gamma ray source and diametrically opposed in a common plane. A formation matrix density output signal is produced in proportion to the output signal from each of the gamma ray sensors and in conjunction with certain constants established by the geometrical configuration of the sensors relative to the gamma ray source and the borehole diameter. Formation density is determined without regard to the radial position of the logging probe within the borehole in a measuring while drilling mode. 6 figs

  16. Advances in gamma-ray burst astronomy

    International Nuclear Information System (INIS)

    Cline, T.L.; Desai, U.D.

    1976-01-01

    Work at Goddard is presently being carried out in three major areas of gamma-ray burst research: (1) A pair of simultaneously operating 0.8-m 2 burst detectors were successfully balloon-borne at locations 800 miles apart on 9 May, 1975, each to atmospheric depths of 3 to 4 g cm -2 , for a 20-h period of coincident data coverage. This experiment investigates the size spectrum of bursts in the 10 -7 to 10 -6 erg cm -2 size region where dozens of events per day are expected on a -1.5 index integral power-law extrapolation. Considerable separation in latitude was used to avoid possible atmospheric and auroral secondary effects. Its results are not yet available. (2) A deep-space burst detector, the first spacecraft instrument built specifically for gamma-ray burst studies, was recently successfully integrated into the Helios-B space probe. Its use at distances of up to 2 AU will make possible the first high-resolution directional study of gamma-ray burst source locations. Similar modifications to several other space vehicles are also being prepared. (3) The gamma-ray instrument on the IMP-7 satellite is presently the most sensitive burst detector still operating in orbit. Its results have shown that all measured event-average energy spectra are consistent with being alike. Using this characteristic spectrum to select IMP-7 candidate events of smaller size than those detected using other spacecraft in coincidence, a size spectrum is constructed which fits the -1.5 index power law down to 2.5 x 10 -5 erg cm -2 per event, at an occurrence rate of about once per month. (Auth.)

  17. Modular gamma systems

    International Nuclear Information System (INIS)

    Millegan, D.R.; Nixon, K.V.

    1982-01-01

    Nuclear safeguards requires sensitive, easily operated instruments for rapid inspection of personnel and vehicles to ensure that no uranium or plutonium is being diverted. Two portable gamma-ray detection systems have been developed. The Modular Gamma System (MGS) is very sensitive and two or more systems can be connected for even better performance. The multiunit configuration can be deployed by motor vehicle for search of large areas too extensive to search on foot. The Programmable Rate Monitor (PRM) is less sensitive but much smaller and therefore is more suitable for search of vehicles, personnel, or smaller areas. The PRM is programmable, which implements measurement and alarm algorithms for individual applications

  18. Proprioceptive evoked gamma oscillations

    DEFF Research Database (Denmark)

    Arnfred, S.M.; Hansen, Lars Kai; Parnas, J.

    2007-01-01

    A proprioceptive stimulus consisting of a weight change of a handheld load has recently been shown to elicit an evoked potential. Previously, somatosensory gamma oscillations have only been evoked by electrical stimuli. We conjectured that a natural proprioceptive stimulus also would be able...... to evoke gamma oscillations. EEG was recorded using 64 channels in 14 healthy subjects. In each of three runs a stimulus of 100 g load increment in each hand was presented in 120 trials. Data were wavelet transformed and runs collapsed. Inter-trial phase coherence (ITPC) was computed as the best measure...

  19. Gamma-Ray Bursts

    Science.gov (United States)

    Pellizza, L. J.

    Gamma-ray bursts are the brightest transient sources in the gamma-ray sky. Since their discovery in the late 1960s, the investigation of the astrophysical sys- tems in which these phenomena take place, and the physical mechanisms that drive them, has become a vast and prolific area of modern astrophysics. In this work I will briefly describe the most relevant observations of these sources, and the models that describe their nature, emphasizing on the in- vestigations about the progenitor astrophysical systems. FULL TEXT IN SPANISH

  20. Gamma Ray Bursts

    Science.gov (United States)

    Gehrels, Neil; Meszaros, Peter

    2012-01-01

    Gamma-ray bursts (GRBs) are bright flashes of gamma-rays coming from the cosmos. They occur roughly once per day ,last typically lOs of seconds and are the most luminous events in the universe. More than three decades after their discovery, and after pioneering advances from space and ground experiments, they still remain mysterious. The launch of the Swift and Fermi satellites in 2004 and 2008 brought in a trove of qualitatively new data. In this review we survey the interplay between these recent observations and the theoretical models of the prompt GRB emission and the subsequent afterglows.

  1. Interferon Gamma-1b Injection

    Science.gov (United States)

    Interferon gamma-1b injection is used to reduce the frequency and severity of serious infections in people with chronic ... severe, malignant osteopetrosis (an inherited bone disease). Interferon gamma-1b is in a class of medications called ...

  2. Gamma knife surgery for craniopharyngioma

    International Nuclear Information System (INIS)

    Prasad, D.; Steiner, M.; Steiner, L.

    1995-01-01

    We present our results of Gamma Knife surgery for craniopharyngioma in nine patients. The current status of surgery, radiation therapy, intracavitary instillation of radionuclides and Gamma Knife surgery in the management of craniopharyngiomas is discussed. (author)

  3. CKM angle $\\gamma$ from LHCb

    CERN Multimedia

    Smith, Jackson

    2015-01-01

    Results of the latest $\\gamma$ combination from LHCb are presented, along with the six LHCb measurements used as inputs. In addition, the anticipated precision attainable for measuring $\\gamma$ after the LHCb Upgrade is outlined

  4. Enhancement of slope efficiency and output power in GaN-based vertical-cavity surface-emitting lasers with a SiO2-buried lateral index guide

    Science.gov (United States)

    Kuramoto, Masaru; Kobayashi, Seiichiro; Akagi, Takanobu; Tazawa, Komei; Tanaka, Kazufumi; Saito, Tatsuma; Takeuchi, Tetsuya

    2018-03-01

    We have achieved a high output power of 6 mW from a 441 nm GaN-based vertical-cavity surface-emitting laser (VCSEL) under continuous wave (CW) operation, by reducing both the internal loss and the reflectivity of the front cavity mirror. A preliminary analysis of the internal loss revealed an enormously high transverse radiation loss in a conventional GaN-based VCSEL without lateral optical confinement (LOC). Introducing an LOC structure enhanced the slope efficiency by a factor of 4.7, with a further improvement to a factor of 6.7 upon reducing the front mirror reflectivity. The result was a slope efficiency of 0.87 W/A and an external differential quantum efficiency of 32% under pulsed operation. A flip-chip-bonded VCSEL also exhibited a high slope efficiency of 0.64 W/A and an external differential quantum efficiency of 23% for the front-side output under CW operation. The reflectivity of the cavity mirror was adjusted by varying the number of AlInN/GaN distributed Bragg reflector pairs from 46 to 42, corresponding to reflectivity values from 99.8% to 99.5%. These results demonstrate that a combination of internal loss reduction and cavity mirror control is a very effective way of obtaining a high output GaN-based VCSEL.

  5. [Analog gamma camera digitalization computer system].

    Science.gov (United States)

    Rojas, G M; Quintana, J C; Jer, J; Astudillo, S; Arenas, L; Araya, H

    2004-01-01

    Digitalization of analogue gamma cameras systems, using special acquisition boards in microcomputers and appropriate software for acquisition and processing of nuclear medicine images is described in detail. Microcomputer integrated systems interconnected by means of a Local Area Network (LAN) and connected to several gamma cameras have been implemented using specialized acquisition boards. The PIP software (Portable Image Processing) was installed on each microcomputer to acquire and preprocess the nuclear medicine images. A specialized image processing software has been designed and developed for these purposes. This software allows processing of each nuclear medicine exam, in a semiautomatic procedure, and recording of the results on radiological films. . A stable, flexible and inexpensive system which makes it possible to digitize, visualize, process, and print nuclear medicine images obtained from analogue gamma cameras was implemented in the Nuclear Medicine Division. Such a system yields higher quality images than those obtained with analogue cameras while keeping operating costs considerably lower (filming: 24.6%, fixing 48.2% and developing 26%.) Analogue gamma camera systems can be digitalized economically. This system makes it possible to obtain optimal clinical quality nuclear medicine images, to increase the acquisition and processing efficiency, and to reduce the steps involved in each exam.

  6. Browse Title Index

    African Journals Online (AJOL)

    2013), Market Sanitation: A Case Study of Oregbeni Market Benin - City Edo ... Pathophysiology and Evidence Based Intervention Strategy, Abstract PDF ... Hormones on Gamma Immunoglobulin Density (Ig-Gp) and Apgar ...

  7. Browse Title Index

    African Journals Online (AJOL)

    Items 101 - 150 of 299 ... Vol 1, No 1 (1996), Energy considerations in building design, Abstract ... Gamma distribution function of instantaneous speeds, Abstract ... Vol 17, No 1-2 (2012), Feasibility of wind power generation in Ghana, Abstract.

  8. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  9. Gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Mori, Yohsimasa; Kida, Yoshihisa

    2003-01-01

    Gamma knife radiosurgery has become a new treatment modality in the field of neurosurgery since the first gamma knife was brought into Japan in 1990. Advances in applications of new indications and long-term results have been continued to evolve during the past 12 years. Based on the experience of more than 4,500 cases treated by gamma knife at Komaki City Hospital, long-term results of arteriovenous malformations (AVMs), metastatic brain tumors, acoustic neurinomas, meningiomas and trigeminal neuralgias are presented. Radiosurgery has become a novel treatment modality, especially for AVM, acoustic neurinoma and meningioma, which were once only treatable by conventional surgery, and shows a high cure rate in AVM cases and high control rate in benign tumors without major complications. The effects of radiosurgery for metastatic brain tumors have been thought to be superior to fractionated radiotherapy due to high response and control rates, and patients showed improved quality of life although no prolongation of the life span was obtained. Gamma knife treatment for trigeminal neuralgia has been shown to be effective and less invasive than microvascular decompression, and is useful for cases resistant to conventional therapies and as an initial treatment as well. (author)

  10. Automated gamma counters

    International Nuclear Information System (INIS)

    Regener, M.

    1977-01-01

    This is a report on the most recent developments in the full automation of gamma counting in RIA, in particular by Messrs. Kontron. The development targets were flexibility in sample capacity and shape of test tubes, the possibility of using different radioisotopes for labelling due to an optimisation of the detector system and the use of microprocessers to substitute software for hardware. (ORU) [de

  11. Gamma cardio 82

    International Nuclear Information System (INIS)

    Itti, R.

    1982-01-01

    New trends in nuclear cardiology are briefly presented supported by a large bibliography. The following topics are reviewed: new tracers of myocardial perfusion and metabolism; quantitative analysis of cardiac function; nuclear stethoscope; gamma emission tomography; diagnostic value of cardiac dynamic tests (at rest and during exercise), pharmacological tests; new clinical applications of cardiovascular nuclear medicine [fr

  12. Industrial radiography. Gamma radiography

    International Nuclear Information System (INIS)

    Menetrier, J.

    1975-01-01

    Informations are given on gamma radiodefectology regulations, entire references and main dispositions applicable to each state of the European Economic Community. The content includes previous arrangements for source acquisition, holding and use of the sources, transport, accidents, civil liability of the source holder, person insurance against radiation hazards and contamination, property insurance, penal liability of the source holder

  13. Introscopy using gamma sources

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Leonov, B.I.; Najorov, A.N.; Smirnov, N.N.; Firstov, V.G.

    1978-01-01

    A method is described of working with standard 170 Tm, 75 Se, 192 Ir, 137 Cs and 60 Co sources at the activity of 1-4000 Ci, during television gamma introscopy of steel products. Experiments involving the RI-10T introscope are carried out to determine prospects of using various radiation sources. The results of using X-ray instruments for control of steel products are also shown for comparison. In introscopy of X-rayed steel products over 25 mm thick, spreading of the edge of the detected groove image is shown to be comparable when using X radiation and gamma radiation of standard sources. Sensitivity of control by fluorographic introscope in X-raying and gamma irradiation of products over 25 mm thick will presumably be the same owing to the detector storage capacity. The use of commercial gamma flaw detecting instruments together with a television introscope permits to reliably reveal defects of 0.5-2.0 mm in size, eliminating possible instability of operation of X-ray instruments, particularly in field conditions

  14. Gamma apparatuses for radiotherapy

    International Nuclear Information System (INIS)

    Sul'kin, A.G.

    1986-01-01

    Scientific and technical achievements in development and application of gamma therapeutic apparatuses for external and intracavity irradiations are generalized. Radiation-physical parameters of apparatuses providing usability of progressive methods in radiotherapy of onclogical patients are given. Optimization of main apparatus elements, ensurance of its operation reliability, reduction of errors of irradiation plan reproduction are considered. Attention is paid to radiation safety

  15. Gamma ray calibration system

    International Nuclear Information System (INIS)

    Rosauer, P.J.; Flaherty, J.J.

    1981-01-01

    This invention is in the field of gamma ray inspection devices for tubular products and the like employing an improved calibrating block which prevents the sensing system from being overloaded when no tubular product is present, and also provides the operator with a means for visually detecting the presence of wall thicknesses which are less than a required minimum. (author)

  16. Collimatorless imaging of gamma rays with help of gamma-ray tracking

    CERN Document Server

    Marel, J V D

    2001-01-01

    In many gamma-ray detector systems that are built for imaging purposes Compton scattered photons are suppressed as much as possible. However, the information from photons that scattered inside a detector system can be used to reconstruct the tracks of the photons with help of gamma-ray tracking. Estimates of the incident directions of the photons can be made and an image can be created. Examples of potential applications for this technique are the use as a gamma-camera in medical imaging (e.g. SPECT) or as a detector for PET. Due to the omission of collimators, much higher detection efficiencies can be achieved, reducing the doses required for an image. A gamma-ray tracking method, called backtracking, has been developed for nuclear spectroscopy. The method tracks gamma-rays originating from a point source in the center of a spherical detector system consisting of position-sensitive germanium detectors. This method can also be used as a tracking technique for imaging of an unknown source distribution. With he...

  17. Studies of weak capture-gamma-ray resonances via coincidence techniques

    CERN Document Server

    Rowland, C; Champagne, A E; Dummer, A K; Fitzgerald, R; Harley, E C T; Mosher, J; Runkle, R

    2002-01-01

    A method for measuring weak capture-gamma-ray resonances via gamma gamma-coincidence counting techniques is described. The coincidence apparatus consisted of a large-volume germanium detector and an annular NaI(Tl) crystal. The setup was tested by measuring the weak E sub R =227 keV resonance in sup 2 sup 6 Mg(p,gamma) sup 2 sup 7 Al. Absolute germanium and NaI(Tl) counting efficiencies for a range of gamma-ray energies and for different detector-target geometries are presented. Studies of the gamma-ray background in our spectra are described. Compared to previous work, our method improves the detection sensitivity for weak capture-gamma-ray resonances by a factor of approx 100. The usefulness of the present technique for investigations of interest to nuclear astrophysics is discussed.

  18. Increased brain uptake of gamma-aminobutyric acid in a rabbit model of hepatic encephalopathy

    International Nuclear Information System (INIS)

    Bassett, M.L.; Mullen, K.D.; Scholz, B.; Fenstermacher, J.D.; Jones, E.A.

    1990-01-01

    Transfer of the inhibitory neurotransmitter gamma-aminobutyric acid across the normal blood-brain barrier is minimal. One prerequisite for gamma-aminobutyric acid in plasma contributing to the neural inhibition of hepatic encephalopathy would be that increased transfer of gamma-aminobutyric acid across the blood-brain barrier occurs in liver failure. The aim of the present study was to determine if brain gamma-aminobutyric acid uptake is increased in rabbits with stage II-III (precoma) hepatic encephalopathy due to galactosamine-induced fulminant hepatic failure. A modification of the Oldendorf intracarotid artery-injection technique was applied. [3H] gamma-aminobutyric acid, [14C] butanol, and 113mIn-labeled serum protein (transferrin) were injected simultaneously 4 s before decapitation. The ipsilateral brain uptake index of gamma-aminobutyric acid was determined from measurements of the 3 isotopes in 5 brain regions. Uncorrected or simple brain uptake indices of [3H] gamma-aminobutyric acid and [113mIn] transferrin were calculated using [14C] butanol as the highly extracted reference compound. The [113mIn] transferrin data were also used to correct the brain uptake index of [3H] gamma-aminobutyric acid for intravascular retention of [3H] gamma-aminobutyric acid. The methodology adopted minimized problems attributable to rapid [3H] gamma-aminobutyric acid metabolism, and slow brain washout and recirculation of the radiolabeled tracers. Both the uncorrected and corrected brain uptake indices of gamma-aminobutyric acid as well as the simple brain uptake index of transferrin were significantly increased in both stage II and III hepatic encephalopathy in all brain regions studied. Moreover, these brain uptake indices were significantly greater in stage III hepatic encephalopathy than in stage II hepatic encephalopathy

  19. Cosmical sources of gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kuchowicz, B [Warsaw Univ. (Poland)

    1974-01-01

    A brief historical outline of the X-ray and ..gamma..-ray astronomies is given first, then a summary of the recent status of X-ray astronomy follows. Further chapters include information on ..gamma..-ray sources in the solar system, in our Galaxy, and beyond it. In discussing linear gamma spectra attention is paid to the possibility of studying explosive nucleo-synthesis by observation of gamma lines from supernova remnants, etc. Questions of the isotropic gamma background are discussed at the end of the survey.

  20. How indexes have changed

    International Nuclear Information System (INIS)

    Farrar, G.L.

    1993-01-01

    The accompanying table compares refinery construction and operating wages monthly for the years 1990 and 1991. The Nelson-Farrar refinery construction cost indexes are inflation indexes, while the operating indexes incorporate a productivity which shows improvement with experience and the increasing size of operations. The refinery construction wage indexes in the table show a steady advance over the 2-year period. Common labor indexes moved up faster than skilled indexes. Refinery operating wages showed a steady increase, while productivities averaged higher near the end of the period. Net result is that labor costs remained steady for the period

  1. A gamma-ray discriminating neutron scintillator

    International Nuclear Information System (INIS)

    Eschbach, P.A.; Miller, S.D.; Cole, M.C.

    1994-01-01

    A neutron scintillator has been developed at Pacific Northwest Laboratory which responds directly to as little as 10 mrem/hour dose equivalent rate fast neutron fields. The scintillator is composed of CaF 2 :Eu or of NaI grains within a silicone rubber or polystyrene matrix, respectively. Neutrons colliding with the plastic matrix provide knockon protons, which in turn deposit energy within the grains of phosphor to produce pulses of light. Neutron interactions are discriminated from gamma-ray events on the basis of pulse height. Unlike NE-213 liquid scintillators, this solid scintillator requires no pulseshape discrimination and therefore requires less hardware. Neutron events are anywhere from two to three times larger than the gamma-ray exposures are compared to 0.7 MeV gamma-ray exposures. The CaF 2 :Eu/silicone rubber scintillator is nearly optically transparent, and can be made into a very sizable detector (4 cm x 1.5 cm) without degrading pulse height. This CaF 2 :Eu scintillator has been observed to have an absolute efficiency of 0.1% when exposed to 5-MeV accelerator-generated neutrons (where the absolute efficiency is the ratio of observed neutron events divided by the number of fast neutrons striking the detector)

  2. Field Applications of Gamma Column Scanning Technology

    International Nuclear Information System (INIS)

    Aquino, Denis D.; Mallilin, Janice P.; Nuñez, Ivy Angelica A.; Bulos, Adelina DM.

    2015-01-01

    The Isotope Techniques Section (ITS) under the Nuclear Service Division (NSD) of the Philippine Nuclear Research Institute (PNRI) conducts services, research and development on radioisotope and sealed source application in the industry. This aims to benefit the manufacturing industries such as petroleum, petrochemical, chemical, energy, waste, column treatment plant, etc. through on line inspection and troubleshooting of a process vessel, column or pipe that could optimize the process operation and increase production efficiency. One of the most common sealed source techniques for industrial applications is the gamma column scanning technology. Gamma column scanning technology is an established technique for inspection, analysis and diagnosis of industrial columns for process optimization, solving operational malfunctions and management of resources. It is a convenient non-intrusive, cost effective and cost-efficient technique to examine inner details of an industrial process vessel such as a distillation column while it is in operation. The Philippine Nuclear Research Institute (PNRI) recognize the importance and benefits of this technology and has implemented activities to make gamma column scanning locally available to benefit the Philippine industries. Continuous effort for capacity building is being pursued thru the implementation of in-house and on-the-job training abroad and upgrading of equipment. (author)

  3. Precise measurement of {gamma}(K{yields}e {nu}({gamma}))/{gamma}(K{yields}{mu} {nu}({gamma})) and study of K{yields}e {nu} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, F.; Massarotti, P.; Meola, S.; Napolitano, M. [Dipartimento di Scienze Fisiche dell' Universita ' ' Federico II' ' , Napoli (Italy); INFN Sezione di Napoli, Napoli (Italy); Antonelli, A.; Antonelli, M.; Bencivenni, G.; Bloise, C.; Bossi, F.; Capon, G.; Capussela, T.; Ciambrone, P.; De Lucia, E.; De Simone, P.; Dreucci, M.; Felici, G.; Gatti, C.; Giovannella, S.; Jacewicz, M.; Lanfranchi, G.; Miscetti, S.; Moulson, M.; Murtas, F.; Palutan, M.; Santangelo, P.; Sciascia, B.; Sibidanov, A.; Spadaro, T.; Venanzoni, G. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Archilli, F. [Dipartimento di Fisica dell' Universita ' ' Tor Vergata' ' , Rome (Italy); INFN Sezione di Roma Tor Vergata, Rome (Italy); Beltrame, P.; Denig, A.; Mueller, S. [Johannes Gutenberg-Universitaet, Institut fuer Kernphysik, Mainz (Germany); Bini, C.; De Santis, A.; De Zorzi, G.; Di Domenico, A.; Fiore, S.; Franzini, P.; Gauzzi, P. [Dipartimento di Fisica dell' Universita ' ' La Sapienza' ' , Rome (Italy); INFN Sezione di Roma, Rome (Italy); Bocchetta, S.; Ceradini, F.; Di Micco, B.; Nguyen, F. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); INFN Sezione di Roma Tre, Rome (Italy); Branchini, P.; Graziani, E.; Passeri, A.; Tortora, L. [INFN Sezione di Roma Tre, Rome (Italy); Capriotti, D. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); Di Donato, C. [INFN Sezione di Napoli, Napoli (Italy); Kulikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lee-Franzini, J. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); State University of New York, Physics Department, Stony Brook (United States); Martini, M.; Patera, V.; Versaci, R. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Energetica dell' Universita ' ' La Sapienza' ' , Rome (Italy); Valente, P. [INFN Sezione di Roma, Rome (Italy)

    2009-12-15

    We present a precise measurement of the ratio R{sub K}={gamma}(K{yields}e{nu}({gamma}))/{gamma}(K{yields}{mu}{nu}({gamma})) and a study of the radiative process K{yields}e{nu}{gamma}, performed with the KLOE detector. The results are based on data collected at the Frascati e{sup +}e{sup -} collider DA {phi}NE for an integrated luminosity of 2.2 fb{sup -1}. We find R{sub K}=(2.493{+-}0.025{sub stat}{+-}0.019{sub syst}) x 10{sup -5}, in agreement with the Standard Model expectation. This result is used to improve constraints on parameters of the Minimal Supersymmetric Standard Model with lepton flavor violation. We also measured the differential decay rate d {gamma}(K{yields}e{nu}{gamma})/dE{sub {gamma}} for photon energies 10gamma}}<250 MeV. Results are compared with predictions from theory. (orig.)

  4. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  5. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  6. Use of gamma probe in 131I thyroid uptake studies

    International Nuclear Information System (INIS)

    Sarmento, Andrea Gondim Leitao

    2002-11-01

    Evaluation of thyroid uptake by administration of radioactive iodine is a well-defined procedure to assess patient thyroid function. In general, nuclear medicine institutions use gamma cameras coupled to pinhole collimators to perform uptake studies. With the growing use of intraoperative gamma probes in the radioguided surgical techniques, several institutions are purchasing this new and portable equipment, which can technically be also employed to assess patient's thyroid function, permitting further other applications of gamma cameras. The aim of the study was to compare thyroid uptake trails carried out with both gamma camera and intraoperative gamma probe, in order to evaluate the possible use of gamma probe for this purpose. At first a preliminary study of feasibility was carried out using a neck phantom to verify equipment efficiency with known activities of 131 I. Henceforth, work data from 12 patients undergone studies of thyroid uptakes were evaluated, 24 hours after oral administration of 370 kBq of 131 I. The maximum difference observed between the values obtained with both equipment was 60%, which demonstrated the feasibility of the proposed protocol and made clear that gamma probe can be useful for thyroid uptake studies. (author)

  7. Fuzzy efficiency without convexity

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Balezentis, Tomas

    2014-01-01

    approach builds directly upon the definition of Farrell's indexes of technical efficiency used in crisp FDH. Therefore we do not require the use of fuzzy programming techniques but only utilize ranking probabilities of intervals as well as a related definition of dominance between pairs of intervals. We...

  8. Imaging capabilities of germanium gamma cameras

    International Nuclear Information System (INIS)

    Steidley, J.W.

    1977-01-01

    Quantitative methods of analysis based on the use of a computer simulation were developed and used to investigate the imaging capabilities of germanium gamma cameras. The main advantage of the computer simulation is that the inherent unknowns of clinical imaging procedures are removed from the investigation. The effects of patient scattered radiation were incorporated using a mathematical LSF model which was empirically developed and experimentally verified. Image modifying effects of patient motion, spatial distortions, and count rate capabilities were also included in the model. Spatial domain and frequency domain modeling techniques were developed and used in the simulation as required. The imaging capabilities of gamma cameras were assessed using low contrast lesion source distributions. The results showed that an improvement in energy resolution from 10% to 2% offers significant clinical advantages in terms of improved contrast, increased detectability, and reduced patient dose. The improvements are of greatest significance for small lesions at low contrast. The results of the computer simulation were also used to compare a design of a hypothetical germanium gamma camera with a state-of-the-art scintillation camera. The computer model performed a parametric analysis of the interrelated effects of inherent and technological limitations of gamma camera imaging. In particular, the trade-off between collimator resolution and collimator efficiency for detection of a given low contrast lesion was directly addressed. This trade-off is an inherent limitation of both gamma cameras. The image degrading effects of patient motion, camera spatial distortions, and low count rate were shown to modify the improvements due to better energy resolution. Thus, based on this research, the continued development of germanium cameras to the point of clinical demonstration is recommended

  9. Western Alaska ESI: INDEX (Index Polygons)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains vector polygons representing the boundaries of all the hardcopy cartographic products produced as part of the Environmental Sensitivity Index...

  10. Determination of gamma ray shielding parameters of rocks and concrete

    Science.gov (United States)

    Obaid, Shamsan S.; Gaikwad, Dhammajyot K.; Pawar, Pravina P.

    2018-03-01

    Gamma shielding parameters such as mass attenuation coefficient (μ/ρ), effective atomic number (Zeff) and electron density (Neff) have been measured and calculated for rocks and concrete in the energy range 122-1330 keV. The measurements have been carried out at 122, 356, 511, 662, 1170, 1275, 1330 keV gamma ray energies using a gamma spectrometer includes a NaI(Tl) scintillation detector and MCA card. The atomic and electronic cross sections have also been investigated. Experimental and calculated (WinXCom) values were compared, and good agreement has been observed within the experimental error. The obtained results showed that feldspathic basalt, compact basalt, volcanic rock, dolerite and pink granite are more efficient than the sandstone and concrete for gamma ray shielding applications.

  11. Exploring the extreme gamma-ray sky with HESS

    International Nuclear Information System (INIS)

    Sol, Helene

    2006-01-01

    The international HESS experiment. High Energy Stereoscopic System, fully operational since January 2004, is opening a new era for extreme gamma-ray astronomy. Located in Namibia, it is now the most sensitive detector for cosmic sources of very high energy (VHE) gamma-rays, in the tera-electron-volt (TeV) range. In July 2005, it had already more than double the number of sources detected at such energies, with the discovery of several active galactic nuclei (AGN), supernova remnants and plerions, a binary pulsar system, a microquasar candidate, and a sample of yet unidentified sources. HESS has also provide for the first time gamma-ray images of extended sources with the first astrophysical jet resolved in gamma-rays, and the first mapping of a shell supernova remnant, which proves the efficiency of in situ acceleration of particles up to 100 TeV and beyond

  12. Calibration and simulation of a gamma array for DRAGON at ISAC

    CERN Document Server

    Gigliotti, D G; Hussein, A H

    2003-01-01

    A gamma ray detector has been built for the DRAGON facility at TRIUMF to detect the gamma ray emitted in astrophysically important proton and alpha radiative capture reactions. The gamma detector was designed to balance cost with maximum solid angle coverage and efficiency. To study the properties of the current design, GEANT simulations are being carried out and compared with prototype measurements using calibration sources and radioactive beams supplied by ISAC. Simulations will be compared with data allowing a realistic simulation to be produced. This modified simulation will then be used to provide efficiency predictions of the gamma array when an actual experiment's parameters are inputted. Using the simulated efficiency of the array, cross sections for radiative capture can be calculated from the measured gamma ray yields, for the individual reactions. The following will outline some initial results of background suppression of beam related experiments. Also shown, are some preliminary comparison of poi...

  13. Master Veteran Index (MVI)

    Data.gov (United States)

    Department of Veterans Affairs — As of June 28, 2010, the Master Veteran Index (MVI) database based on the enhanced Master Patient Index (MPI) is the authoritative identity service within the VA,...

  14. Human Use Index (Future)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Human land uses may have major impacts on ecosystems, affecting biodiversity, habitat, air and water quality. The human use index (also known as U-index) is the...

  15. Human Use Index

    Data.gov (United States)

    U.S. Environmental Protection Agency — Human land uses may have major impacts on ecosystems, affecting biodiversity, habitat, air and water quality. The human use index (also known as U-index) is the...

  16. IndexCat

    Data.gov (United States)

    U.S. Department of Health & Human Services — IndexCat provides access to the digitized version of the printed Index-Catalogue of the Library of the Surgeon General's Office; eTK for medieval Latin texts; and...

  17. Body Mass Index Table

    Science.gov (United States)

    ... Families ( We Can! ) Health Professional Resources Body Mass Index Table 1 for BMI greater than 35, go ... Health Information Email Alerts Jobs and Careers Site Index About NHLBI National Institute of Health Department of ...

  18. Gamma counter calibration system

    International Nuclear Information System (INIS)

    1977-01-01

    A method and apparatus are described for the calibration of a gamma radiation measurement instrument to be used over any of a number of different absolute energy ranges. The method includes the steps of adjusting the overall signal gain associated with pulses which are derived from detected gamma rays, until the instrument is calibrated for a particular absolute energy range; then storing parameter settings corresponding to the adjusted overall signal gain, and repeating the process for other desired absolute energy ranges. The stored settings can be subsequently retrieved and reapplied so that test measurements can be made using a selected one of the absolute energy ranges. Means are provided for adjusting the overall signal gain and a specific technique is disclosed for making coarse, then fine adjustments to the signal gain, for rapid convergence of the required calibration settings. (C.F.)

  19. Gamma-ray bursts

    CERN Document Server

    Wijers, Ralph A M J; Woosley, Stan

    2012-01-01

    Cosmic gamma ray bursts (GRBs) have fascinated scientists and the public alike since their discovery in the late 1960s. Their story is told here by some of the scientists who participated in their discovery and, after many decades of false starts, solved the problem of their origin. Fourteen chapters by active researchers in the field present a detailed history of the discovery, a comprehensive theoretical description of GRB central engine and emission models, a discussion of GRB host galaxies and a guide to how GRBs can be used as cosmological tools. Observations are grouped into three sets from the satellites CGRO, BeppoSAX and Swift, and followed by a discussion of multi-wavelength observations. This is the first edited volume on GRB astrophysics that presents a fully comprehensive review of the subject. Utilizing the latest research, Gamma-ray Bursts is an essential desktop companion for graduate students and researchers in astrophysics.

  20. Gamma ray camera

    International Nuclear Information System (INIS)

    Wang, S.-H.; Robbins, C.D.

    1979-01-01

    An Anger gamma ray camera is improved by the substitution of a gamma ray sensitive, proximity type image intensifier tube for the scintillator screen in the Anger camera. The image intensifier tube has a negatively charged flat scintillator screen, a flat photocathode layer, and a grounded, flat output phosphor display screen, all of which have the same dimension to maintain unit image magnification; all components are contained within a grounded metallic tube, with a metallic, inwardly curved input window between the scintillator screen and a collimator. The display screen can be viewed by an array of photomultipliers or solid state detectors. There are two photocathodes and two phosphor screens to give a two stage intensification, the two stages being optically coupled by a light guide. (author)

  1. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.; Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  2. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  3. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  4. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  5. Preservation and gamma irradiation

    International Nuclear Information System (INIS)

    Ramiere, R.

    1991-01-01

    The paper reviews briefly the application of gamma radiation to preservation of cultural objects for disinsectization, disinfection and strengthening of materials such as wood or stone by impregnation with a liquid resin and in situ polymerization. As heavy equipment is required two facilities are specialized a 1000 T Bq cobalt 60 source at Grenoble (France) and 100 T Bq one at Rostoky (Czechoslovakia). Examples of treated objects are given [fr

  6. Gamma radiation in apartments

    International Nuclear Information System (INIS)

    Grindborg, J.-E.

    1983-05-01

    This investigation forms the basis for the description of methods for the detection of gamma radiation. The aim is to control that the dose limit will not exceed 50 μR/h in a room where people reside. The distribution of dose rates in different rooms has been calculated and the results have been compared with experimental data. Various instruments have been calibrated and their specifications are discussed. (G.B.)

  7. Encapsulation Efficiency, Oscillatory Rheometry

    Directory of Open Access Journals (Sweden)

    Z. Mohammad Hassani

    2014-01-01

    Full Text Available Nanoliposomes are one of the most important polar lipid-based nanocarriers which can be used for encapsulation of both hydrophilic and hydrophobic active compounds. In this research, nanoliposomes based on lecithin-polyethylene glycol-gamma oryzanol were prepared by using a modified thermal method. Only one melting peak in DSC curve of gamma oryzanol bearing liposomes was observed which could be attributed to co-crystallization of both compounds. The addition of gamma oryzanol, caused to reduce the melting point of 5% (w/v lecithin-based liposome from 207°C to 163.2°C. At high level of lecithin, increasing of liposome particle size (storage at 4°C for two months was more obvious and particle size increased from 61 and 113 to 283 and 384 nanometers, respectively. The encapsulation efficiency of gamma oryzanol increased from 60% to 84.3% with increasing lecithin content. The encapsulation stability of oryzanol in liposome was determined at different concentrations of lecithin 3, 5, 10, 20% (w/v and different storage times (1, 7, 30 and 60 days. In all concentrations, the encapsulation stability slightly decreased during 30 days storage. The scanning electron microscopy (SEM images showed relatively spherical to elliptic particles which indicated to low extent of particles coalescence. The oscillatory rheometry showed that the loss modulus of liposomes were higher than storage modulus and more liquid-like behavior than solid-like behavior. The samples storage at 25°C for one month, showed higher viscoelastic parameters than those having been stored at 4°C which were attributed to higher membrane fluidity at 25°C and their final coalescence.Nanoliposomes are one of the most important polar lipid based nanocarriers which can be used for encapsulation of both hydrophilic and hydrophobic active compounds. In this research, nanoliposomes based on lecithin-polyethylene glycol-gamma oryzanol were prepared by using modified thermal method. Only one

  8. Gamma surgery for hemangiopericytomas

    International Nuclear Information System (INIS)

    Payne, B.R.; Prasad, D.; Steiner, M.; Steiner, L.

    2000-01-01

    A retrospective analysis of a consecutive series of 12 patients with 15 intracranial hemangiopericytomas treated at the University of Virginia using gamma surgery is presented. Clinical and radiographic follow up of 3 to 56 months is available for 10 patients with 12 tumors. There was one tumor present at the time of initial gamma surgery in each patient. Two new tumors occurred in patients previously treated. Nine of the tumors decreased in volume and three remained stable. Four of the nine tumors that shrank later progressed at an average of 22 months after treatment. Of the tumors that decreased in volume and have not progressed, the response has been for an average of 11 months. The follow-up for two tumors that remained unchanged was 10 and 34 months (average 22 months). A third tumor was unchanged at 42 months but the patient died of new disease adjacent to the treated area in the anterior skull base. There were no complications and the quality of life following the procedure was maintained or improved in every case. Gamma surgery is effective in palliating the patients by decreasing tumor volume and delaying recurrence. (author)

  9. gamma. radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1948-12-08

    Following the work of Ward (Proc Cambridge Phil Soc 35 322(1939)), the ..gamma..-radiation of ionium (from an IoTh preparation) was studied with the aid of Ta and W screens, and an aluminum counter. The screen measurements confirmed Ward's findings of two radiations, of 68 keV and of about 200 keV. The number of quanta per second of each radiation was determined with the counter, which has been calibrated on certain L lines of radium. The global quanta number of L lines of ionium was also determined. The results were as follows: 0.7 quanta ..gamma.. of 68 keV for 100 ..cap alpha..-particles; 0.2 quanta ..gamma.. of 200 keV for 100 ..cap alpha..-particles; 10 quanta L for 100 ..cap alpha..-particles. These data, which show an important internal conversion, agree with the findings of Teillac (Compt Rend 227 1227 (1948)), who investigated the ..beta..-radiation of ionium. It is the radiation 68 keV which is highly converted. On the other hand, these results do no agree with the data on the fine structure of ionium found by Rosenblum, Valadares, and Vial (Compt Rend 227 1088(1948)).

  10. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  11. Crystal-diffraction spectrometer of increased efficiency

    International Nuclear Information System (INIS)

    Saukov, A.I.; Gornitsyn, G.A.; Morozov, N.A.

    1985-01-01

    The geometry of the spectrometer is illustrated in this paper. An attempt is made to achieve optimal design of the spectrometer by finding the coefficient of reflection of the gamma radiation from the various Ge planes. In these experiments, the Du Mond design was used in the spectrometer. Illustrations are provided to explain dependence of the relative efficiency upon the energy of the gamma quanta

  12. Disinfection of water and wastewater of Isfahan water and wastewater treatment plants by gamma irradiation

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Amin

    2013-01-01

    Conclusion: At gamma doses used in this study, the coliforms were removed completely. But for wastewater samples, although the removal efficiencies were above 80%, the environmental standards related to microbial parameters were not satisfied. Therefore, it is necessary to use higher doses of gamma radiation.

  13. Response functions of NaI(Tl) detectors to terrestrial gamma radiation

    International Nuclear Information System (INIS)

    Gyurcsak, J.; Lenda, A.

    1978-01-01

    Computer programs, serving for calculation of detector efficiency and energy deposition spectrum for scintillation crystals irradiated by isotropic or half-isotropic gamma-ray fields were elaborated. The Monte-Carlo models used in calculations are valid for gamma-ray energies 2 π geometry by the 1.5'' x 2'' probe with experimental results is given. (author)

  14. Determination of correction factors for borehole natural gamma-ray measurements by Monte Carlo simulations

    NARCIS (Netherlands)

    Maucec, M.; Hendriks, Peter; Limburg, J.; de Meijer, R. J.

    2009-01-01

    The analysis of natural gamma-ray spectra measured in boreholes has to take into account borehole parameters such as the presence of casings and borehole diameter. For large, high-efficiency gamma-ray detectors, such as BGO-based systems, which employ full-spectrum data analysis, corresponding

  15. Study of the functional characteristics of a NaI(Tl) scintillator gamma spectrometer

    International Nuclear Information System (INIS)

    Jesus Barbosa, S. de.

    1983-01-01

    Functional characteristics (resolution, stability, linearity, counting efficiency) of a NaI(Tl) scintillator gamma spectrometer were studied. Diagrams were plotted and several standard sources ( 241 Am, 109 Cd, 57 Co, 137 Cs, 54 Mn, 22 Na) with gamma energies ranging from 60 to 1275 KeV were used. (C.L.B.) [pt

  16. Differential androgenesis in gamma irradiated mice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jihyang; Yoon, Yongdal [Hanyang Univ., Seoul (Korea, Republic of); Kim, Jin Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2002-07-01

    The Leydig cells of the testis account for at least 75% of the total testosterone produced in the normal adult male. Whereas the production of estrogen from androgen is catalyzed by aromatase cytochrome P450, which is found in many tissues, including gonad, brain, adipose tissue, bone, and heart. The gamma-irradiation causes the impairment of spermatogenesis and steroidogenesis in male mice. The present study was performed to analyze changes in testosterone concentrations and expression of steroidogenic enzyme of mice after whole body gamma-irradiation. Eight-week-old male ICR mice were irradiated with 6.5 or 10 Gy. At days 1, 2, 3, 4, and 5 after irradiation, testes were removed and processed for paraffin sections and isolation of mRNA. We calculated the gonad index from body and testis weight, and checked the testis volume. Hormonal analysis was performed by means of radioimmunoassay (RIA) in serum and intratesticular fluid. Semiquantitative reverse transcription polymerase chain reaction (RT-PCR) was used to evaluate the expression kinetics of the apoptotic gene and the cytochrome P450 aromatase gene after irradiation. In gamma-irradiated mice, the body weight reduced in comparison to that of the control group. Therefore, gonad indices increased. The testosterone concentrations in serum and intratesticular fluid were significantly reduced. RT- PCR data represented that the expression of Fas, Fas ligand, and aromatase cytochrome P450 showed the specific patterns against control groups. These results indicated that gamma- irradiation of adult mice induced the alteration of androgenesis and suggested that might counteract the spermatogenesis.

  17. SU-G-BRB-16: Vulnerabilities in the Gamma Metric

    International Nuclear Information System (INIS)

    Neal, B; Siebers, J

    2016-01-01

    Purpose: To explore vulnerabilities in the gamma index metric that undermine its wide use as a radiation therapy quality assurance tool. Methods: 2D test field pairs (images) are created specifically to achieve high gamma passing rates, but to also include gross errors by exploiting the distance-to-agreement and percent-passing components of the metric. The first set has no requirement of clinical practicality, but is intended to expose vulnerabilities. The second set exposes clinically realistic vulnerabilities. To circumvent limitations inherent to user-specific tuning of prediction algorithms to match measurements, digital test cases are manually constructed, thereby mimicking high-quality image prediction. Results: With a 3 mm distance-to-agreement metric, changing field size by ±6 mm results in a gamma passing rate over 99%. For a uniform field, a lattice of passing points spaced 5 mm apart results in a passing rate of 100%. Exploiting the percent-passing component, a 10×10 cm"2 field can have a 95% passing rate when an 8 cm"2=2.8×2.8 cm"2 highly out-of-tolerance (e.g. zero dose) square is missing from the comparison image. For clinically realistic vulnerabilities, an arc plan for which a 2D image is created can have a >95% passing rate solely due to agreement in the lateral spillage, with the failing 5% in the critical target region. A field with an integrated boost (e.g whole brain plus small metastases) could neglect the metastases entirely, yet still pass with a 95% threshold. All the failure modes described would be visually apparent on a gamma-map image. Conclusion: The %gamma<1 metric has significant vulnerabilities. High passing rates can obscure critical faults in hypothetical and delivered radiation doses. Great caution should be used with gamma as a QA metric; users should inspect the gamma-map. Visual analysis of gamma-maps may be impractical for cine acquisition.

  18. Fermi Discovery of Gamma-Ray Emission from NGC 1275

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, Aous A.; /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Asano, K.; /Tokyo Inst. Tech.; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, Guido; /INFN, Trieste /Trieste U.; Bastieri, Denis; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bellazzini, R.; /INFN, Pisa; Blandford, R.D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bloom, Elliott D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bonamente, E.; /INFN, Perugia /Perugia U.; Borgland, A.W.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bregeon, J.; /INFN, Pisa; Brez, A.; /INFN, Pisa; Brigida, M.; /Bari U. /INFN, Bari; Bruel, P.; /Ecole Polytechnique; Burnett, Thompson H.; /Washington U., Seattle; Caliandro, G.A.; /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /IASF, Milan /IASF, Milan /DAPNIA, Saclay /ASDC, Frascati /INFN, Perugia /Perugia U. /SISSA, Trieste /George Mason U. /Naval Research Lab, Wash., D.C. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Montpellier U. /ASDC, Frascati /Sonoma State U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /Stockholm U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Naval Research Lab, Wash., D.C. /INFN, Trieste /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /CENBG, Gradignan /CENBG, Gradignan /Montpellier U. /Bari U. /INFN, Bari /Naval Research Lab, Wash., D.C. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Trieste /Hiroshima U.; /more authors..

    2009-05-15

    We report the discovery of high-energy (E > 100 MeV) {gamma}-ray emission from NGC 1275, a giant elliptical galaxy lying at the center of the Perseus cluster of galaxies, based on observations made with the Large Area Telescope (LAT) of the Fermi Gamma-ray Space Telescope. The positional center of the {gamma}-ray source is only {approx}3{prime} away from the NGC 1275 nucleus, well within the 95% LAT error circle of {approx}5{prime}. The spatial distribution of {gamma}-ray photons is consistent with a point source. The average flux and power-law photon index measured with the LAT from 2008 August 4 to 2008 December 5 are F{sub {gamma}} = (2.10 {+-} 0.23) x 10{sup -7} ph (>100 MeV) cm{sup -2} s{sup -1} and {Gamma} = 2.17 {+-} 0.05, respectively. The measurements are statistically consistent with constant flux during the four-month LAT observing period. Previous EGRET observations gave an upper limit of F{sub {gamma}} < 3.72 x 10{sup -8} ph (>100 MeV) cm{sup -2} s{sup -1} to the {gamma}-ray flux from NGC 1275. This indicates that the source is variable on timescales of years to decades, and therefore restricts the fraction of emission that can be produced in extended regions of the galaxy cluster. Contemporaneous and historical radio observations are also reported. The broadband spectrum of NGC 1275 is modeled with a simple one-zone synchrotron/synchrotron self-Compton model and a model with a decelerating jet flow.

  19. Two Dimensional Verification of the Dose Distribution of Gamma Knife Model C using Monte Carlo Simulation with a Virtual Source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hoon; Kim, Yong-Kyun; Lee, Cheol Ho; Son, Jaebum; Lee, Sangmin; Kim, Dong Geon; Choi, Joonbum; Jang, Jae Yeong [Hanyang University, Seoul (Korea, Republic of); Chung, Hyun-Tai [Seoul National University, Seoul (Korea, Republic of)

    2016-10-15

    Gamma Knife model C contains 201 {sup 60}Co sources located on a spherical surface, so that each beam is concentrated on the center of the sphere. In the last work, we simulated the Gamma Knife model C through Monte Carlo simulation code using Geant4. Instead of 201 multi-collimation system, we made one single collimation system that collects source parameter passing through the collimator helmet. Using the virtual source, we drastically reduced the simulation time to transport 201 gamma circle beams to the target. Gamma index has been widely used to compare two dose distributions in cancer radiotherapy. Gamma index pass rates were compared in two calculated results using the virtual source method and the original method and measured results obtained using radiocrhomic films. A virtual source method significantly reduces simulation time of a Gamma Knife Model C and provides equivalent absorbed dose distributions as that of the original method showing Gamma Index pass rate close to 100% under 1mm/3% criteria. On the other hand, it gives a little narrow dose distribution compared to the film measurement showing Gamma Index pass rate of 94%. More accurate and sophisticated examination on the accuracy of the simulation and film measurement is necessary.

  20. Automatic Sample Changing System for Gamma-Ray Spectrometry; Changeur Automatique d'Echantillons Pourla Spectrometrie Gamma; Avtomaticheskaya sistema dlya smeny obraztsov pri gamma-spektrometrii; Cambiador Automatico de Muestras para Espectroscopia Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Lamson, K. C.; Sesko, W. J.; Nicholson, G. C. [Northeastern Radiological Health Laboratory, Winchester, MA (United States)

    1965-10-15

    The detection of gamma-emitting radionuclides at environmental levels in biological media requires that the sensitivity of the counting system be high. To accumulate sufficiently precise data, it is often necessary to count samples for long periods of time - from one to several hours. The most efficient utilization of expensive low-background gamma-ray spectrometric counting equipment requires that it be operated on a continuous basis. This necessitates either the continuous presence of personnel or a completely automated system, including the changing of samples and recording of data. The purpose of this paper is to describe the automated gamma-ray spectrometry counting system designed, built and in use at the Northeastern Radiological Health Laboratory, Winchester, Massachusetts. The sample changing unit was designed to operate in conjunction with a large steel shield, any commercial unit with a front opening door being readily adaptable for this purpose. The changer is equipped to handle a variety of samples including biological and medical types. The unit consists of a revolving tray with a capacity for sixteen samples, an indexing system for positioning the samples, a mechanical arm with an attached electromagnet for inserting and removing the samples from the shield, and a lever for opening and closing the shield door. The changer has been completely integrated with a multichannel analyser with the provision of safety features to interrupt the cycle in case of malfunction at any step. After a preset counting period, the data are punched onto paper tape and processed by an IBM. 1620 computer. The first model of the sample changer, for which a patent is pending, has been in operation at the Northeastern Radiological Health Laboratory for about one year. During that time, it has been used extensively and has proven completely satisfactory. The total cost of the unit, including labour, was less than $ 2000. (author) [French] GAMMAPour deceler les radionucleides